WorldWideScience

Sample records for sterilization metody sterylizacji

  1. Methods of medical sterilization; Metody sterylizacji medycznej

    Energy Technology Data Exchange (ETDEWEB)

    Stachowicz, W. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    Broad review of different (physical, chemical and mechanical) methods commonly used for medical materials sterilization have been performed. Among them the special attention have been played on radiosterilization. The advantages and weaknesses each of the presented method have been pointed out. 1 fig.

  2. Materials of 4. Spring School of Radiation Sterilization of Medical Materials, Grafts, Pharmaceutics and Cosmetics; Materialy 4. Wiosennej Szkoly Sterylizacji Radiacyjnej Sprzetu Medycznego, Przeszczepow, Farmaceutykow i Kosmetykow

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-01

    The state of art in well developed in Poland radiation technologies has been done. The legal and economical aspects have been discussed for radiation sterilization of health care products, drugs, biomaterials and grafts. Industrial plants and radiation procedures have been described. The perspectives for further development and other industrial applications have been also discussed.

  3. Proceedings of 3. autumn school of radiation sterilization of medical utensils and grafts; 3. jesiennea szkola sterylizacji radiacyjnej sprzetu medycznego i przeszczepow

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The Polish experience and review of worldwide development of radiation techniques and technologies have been presented and discussed in the field of radiation sterilization of medical supplies and grafts as well as for food processing. These problems have found now in Poland industrial or pilot plant solutions. Also some technologies connected with medical utensils production from with polymeric material resistant for radiation have been developed in Poland.

  4. Metodi Matematici della Fisica

    CERN Document Server

    Cicogna, Giampaolo

    2008-01-01

    Questo testo trae la sua origine da miei vecchi appunti, preparati per il corso di Metodi Matematici della Fisica e via via sistemati, raffinati e aggiornati nel corso di molti anni di insegnamento. L'obiettivo è stato sempre quello di fornire una presentazione per quanto possibile semplice e diretta dei metodi matematici rilevanti per la Fisica: serie di Fourier, spazi di Hilbert, operatori lineari, funzioni di variabile complessa, trasformata di Fourier e di Laplace, distribuzioni. Oltre a questi argomenti di base, viene presentata, in Appendice, una breve introduzione alle prime nozioni di teoria dei gruppi, delle algebre di Lie e delle simmetrie in vista delle loro applicazioni alla Fisica. Anche allo scopo di mantenere il libro nei limiti ragionevoli di un manuale di dimensioni contenute e di agevole consultazione, sono stati spesso tralasciati i dettagli tecnici delle dimostrazioni matematiche (o anzi le dimostrazioni per intero) e tutti i formalismi eccessivi che spesso nascondono la vera natura del p...

  5. Implementace metody Balanced Scorecard

    OpenAIRE

    Neuwirth, Pavel

    2014-01-01

    Diplomová práce je zaměřena na hodnocení výkonnosti společnosti pomocí metody Balanced Scorecard. Teoretická část práce popisuje východiska měření výkonnosti, metody Balanced Scorecard a postup při její implementaci. Analytická část vychází z teoretických poznatků z první části a hodnotí situaci společnosti finanční analýzou poměrových ukazatelů, strategickou analýzou a následným sestavením návrhu implementace metody Balanced Scorecard v konkrétní společnosti. Thesis is focused on evaluati...

  6. Metodi matematici della fisica

    CERN Document Server

    Cicogna, Giampaolo

    2015-01-01

    Questo libro trae la sua origine dagli appunti preparati per le lezioni di Metodi Matematici della Fisica tenute al Dipartimento di Fisica dell'Università di Pisa, e via via sistemati, raffinati e aggiornati nel corso di molti anni di insegnamento. L'intento generale è di fornire una presentazione per quanto possibile semplice e diretta dei metodi matematici basilari e rilevanti per la Fisica. Anche allo scopo di mantenere questo testo entro i limiti di un manuale di dimensioni contenute e di agevole consultazione, sono stati spesso sacrificati i dettagli tecnici delle dimostrazioni matematiche (o anzi le dimostrazioni per intero) e anche i formalismi eccessivi, che tendono a nascondere la vera natura dei problemi. Al contrario, si è cercato di evidenziare – per quanto possibile – le idee sottostanti e le motivazioni che conducono ai diversi procedimenti. L'obiettivo principale e quello di mettere in condizione chi ha letto questo libro di acquisire gli strumenti adatti e le conoscenze di base che gli ...

  7. International regulations concerning radiosterilization; Aktualne przepisy miedzynarodowe dotyczace sterylizacji radiacyjnej

    Energy Technology Data Exchange (ETDEWEB)

    Kaluska, I. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    European norms (EN 552) and international regulations (ISO 11137) concerning commercial radiosterilization have been described. Licensing of irradiation installation as well as sterilization procedure requirements, and routine control have been discussed in detail. 3 refs.

  8. Microbiological problems in radiosterilization; Zagadnienia mikrobiologiczne w sterylizacji radiacyjnej

    Energy Technology Data Exchange (ETDEWEB)

    Czerniawski, E. [Lodz Univ. (Poland)

    1997-10-01

    Microbiological problems connected with radiosterilization of medical materials, pharmaceuticals and cosmetics have been discussed in detail. Dose-response relationship for different bacteria has been shown. Recommended sterilization and postirradiation control procedures have been described. 24 refs, 6 figs, 5 tabs.

  9. PRIMERJAVA IZGRADNJE ŽELEZNIŠKE PROGE PO KLASIČNI METODI IN PO METODI TIRA NA TOGI PODLAGI

    OpenAIRE

    Pirš, Jurij

    2011-01-01

    Diplomska naloga obravnava primerjavo tehnologije gradnje železniške proge po klasični metodi in po metodi tira na togi podlagi. Predstavljene so osnovne zahteve za projektiranje železniške proge in kriteriji za izdelavo posameznih elementov spodnjega in zgornjega ustroja proge skupaj z opisom in uporabo gradbene mehanizacije. V nadaljevanju sledi predstavitev uporabe tehnologije tira na togi podlagi v predorih na odseku Košana – Gornje Ležeče. Prikazana je podrobna analiza togega tira s...

  10. Spacecraft sterilization.

    Science.gov (United States)

    Kalfayan, S. H.

    1972-01-01

    Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.

  11. Reversible Sterilization

    Science.gov (United States)

    Largey, Gale

    1977-01-01

    Notes that difficult questions arise concerning the use of sterilization for alleged eugenic and euthenic purposes. Thus, how reversible sterilization will be used with relation to the poor, mentally ill, mentally retarded, criminals, and minors, is questioned. (Author/AM)

  12. Sterilization System

    Science.gov (United States)

    1990-01-01

    Cox Sterile Products, Inc.'s Rapid Heat Transfer Sterilizer employs a heat exchange process that induces rapid air movement; the air becomes the heat transfer medium, maintaining a uniform temperature of 375 degrees Fahrenheit. It features pushbutton controls for three timing cycles for different instrument loads, a six-minute cycle for standard unpackaged instruments, eight minutes for certain specialized dental/medical instruments and 12 minutes for packaged instruments which can then be stored in a drawer in sterile condition. System will stay at 375 degrees all day. Continuous operation is not expensive because of the sterilizer's very low power requirements.

  13. Sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, J. [PRISMA Cluster of Excellence & Mainz Institute for Theoretical Physics, Johannes Gutenberg University, 55099 Mainz (Germany); Machado, P. A. N., E-mail: pedro.machado@uam.es [Departamento de Física Teórica, Universidad Autónoma de Madrid, Cantoblanco E-28049 Madrid (Spain); Instituto de Física Teórica UAM/CSIC, Calle Nicolás Cabrera 13-15, Cantoblanco E-28049 Madrid (Spain); Maltoni, M. [Instituto de Física Teórica UAM/CSIC, Calle Nicolás Cabrera 13-15, Cantoblanco E-28049 Madrid (Spain); Schwetz, T. [Institute for Nuclear Physics, Karlsruhe Institute of Technology (KIT), Postfach 3640, 76021 Karlsruhe (Germany)

    2016-06-21

    We characterize statistically the indications of a presence of one or more light sterile neutrinos from MiniBooNE and LSND data, together with the reactor and gallium anomalies, in the global context. The compatibility of the aforementioned signals with null results from solar, atmospheric, reactor, and accelerator experiments is evaluated. We conclude that a severe tension is present in the global fit, and therefore the addition of eV-scale sterile neutrinos does not satisfactorily explain the anomalies.

  14. Interpretazione matematico-statistica dei metodi di stima diretti

    Directory of Open Access Journals (Sweden)

    Gabriele Brondino

    2011-12-01

    Full Text Available Partendo dai presupposti dettati dai postulati estimativi dell’ordinarietà, della previsione e della comparazione, il legame tra la stima del Valore di Mercato e il Prezzo di Compravendita può essere spiegato da un punto di vista matematico. Il modello di Prezzo di Compravendita e un campione estimativo significativo sono strumenti centrali per lo sviluppo di uno dei qualsiasi metodi di stima diretti del Valore di Mercato. Obiettivo del presente studio è quello di descrivere le relazioni matematico-statistiche - nonché le difficoltà di applicazione – alla base dei metodi di stima diretti, prendendo spunto da casi studio pseudo-reali. Di seguito si prenderà quindi in considerazione un campione estimativo particolarmente numeroso e si fornirà una stima del Valore di Mercato del bene oggetto di stima attraverso la metodologia statistica nota come Regressione lineare multipla; si provvederà quindi ad applicare anche il cosiddetto Sales Comparison Approach (SCA per stimare il Valore di Mercato nel caso di un campione estimativo di bassa numerosità. Infine si valuterà l'utilità pratica e le condizioni di applicazioni di un metodo di stima noto come Nearest Neighbors Appraisal Technique (NNAT.

  15. Evaluation of the toxicity of radiosterilized implantable materials; Ocena wplywu sterylizacji radiacyjnej na toksycznosc wybranych materialow implantacyjnych

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowska-Szumiel, M.; Kudelska, D.; Mazur, M. [Akademia Medyczna, Wroclaw (Poland); Zimek, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-12-01

    Autoclave and radiation sterilization modes of selected biomaterials and polymers were studied to evaluate the toxicity, if any, induced in the cells grown in vitro. The materials examined induced: crystalline and amorphous biocarbon, alumina, hydroxyapatite, powdered primary PP (radiation-sensitive), and PP modified with a polypropylene/ethylene or an ethylene/vinyl acetate copolymer to enhance its radiation resistance. Results showed no material to be toxic toward the cell examined. The viability of the cells cultivated in the presence of materials examined was found to remain unaffected regardless of the sterilization mode. (author). 12 refs, 3 figs.

  16. Moderní metody hodnocení polymerů

    OpenAIRE

    Ropek, Lukáš

    2012-01-01

    Práce tvoří přehled současných moderních metod hodnocení polymerů. První část se zabývá historickým vývojem, jednotlivými druhy a přípravou samotných polymerů. Dále je práce zaměřena na samotnou strukturu polymerů, popis moderních přístupů tvorby vzorků a metod studia struktury polymerů. Poté jsou v práci diskutovány mechanické vlastnosti polymerů a metody jejich zkoušení. Závěrem je pak práce zaměřena na konkrétní testy odolnosti trubkových polymerních materiálů používaných v současné praxi....

  17. Interval Female Sterilization.

    Science.gov (United States)

    Stuart, Gretchen S; Ramesh, Shanthi S

    2018-01-01

    Female sterilization is relied on by nearly one in three women aged 35-44 years in the United States. Sterilization procedures are among the most common procedures that obstetrician-gynecologists perform. The most frequent sterilization procedures include postpartum tubal ligation, laparoscopic tubal disruption or salpingectomy, and hysteroscopic tubal occlusion. The informed consent process for sterilization is crucial and requires shared decision-making between the patient and the health care provider. Counseling should include the specific risks and benefits of the specific surgical approaches. Additionally, women should be counseled on the alternatives to sterilization, including intrauterine contraceptives and subdermal contraceptive implants. Complications, including unplanned pregnancy after successful female sterilization, are rare. The objectives of this Clinical Expert Series are to describe the epidemiology of female sterilization, access to postpartum sterilization, advances in interval sterilization techniques, and clinical considerations in caring for women requesting sterilization.

  18. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  19. Stochastické metody v řízení projektů

    OpenAIRE

    Zemenová, Hana

    2007-01-01

    Každý projekt je ze své povahy spojen s jistou dávkou rizika a nejistoty, kterou je nutné zohlednit při volbě adekvátních metod pro jeho řízení. Cílem práce je tyto metody klasifikovat, porovnat a aplikovat na případové studii z podnikové praxe. Podrobněji jsou přitom rozebrány právě ty metody, které byly vhodné pro zkoumaný projekt z případové studie: jedná se o metodu CPM/PERT, simulaci Monte Carlo a analýzu projektu prostřednictvím bayesovských sítí.

  20. Le prime sensazioni al pianoforte restano per sempre? Indagine sui metodi pianistici per principianti

    Directory of Open Access Journals (Sweden)

    Giuseppe Sellari

    2015-12-01

    Full Text Available I metodi d’insegnamento del pianoforte utilizzati in Italia sono caratterizzati da percorsi basati su differenti ipotesi teoriche e indicazioni pratiche. Il primo libro di pianoforte, qualunque sia il suo valore, stabilisce il primo contatto con lo strumento, lasciando una forte impressione e tracciando il profilo delle competenze inizialmente sviluppate. Una più profonda comprensione di questi testi può mostrare quali sono le capacità e le strategie di apprendimento proposte dai metodi adottati e conseguentemente dagli insegnanti. L'obiettivo di questo studio è quello di identificare quali sono le scelte metodologiche più rappresentative nella didattica pianistica italiana degli ultimi 50 anni. I risultati sono basati sui dati raccolti dai questionari somministrati a 200 pianisti, di età compresa tra 20 e 60, ai quali è stato chiesto, insieme a informazioni generiche, quale fosse stato il loro primo libro pianoforte, quali aspetti positivi o negativi ricordavano maggiormente e quali ritenevano essere più utili. I dati suggeriscono una preferenza rilevante di cinque metodi, che sono stati analizzati secondo una serie di criteri metodologici e analitici. I risultati indicano un panorama metodologico concentrato principalmente sul rapporto iniziale con lo strumento e sulla lettura musicale. Questo studio contribuisce alla riflessione su due aspetti metodologici: lo sviluppo di nuovi repertori e la proposta di metodologie in grado di rispettare il mondo emotivo e cognitivo dei principianti.

  1. Sterile neutrinos in cosmology

    Science.gov (United States)

    Abazajian, Kevork N.

    2017-11-01

    Sterile neutrinos are natural extensions to the standard model of particle physics in neutrino mass generation mechanisms. If they are relatively light, less than approximately 10 keV, they can alter cosmology significantly, from the early Universe to the matter and radiation energy density today. Here, we review the cosmological role such light sterile neutrinos can play from the early Universe, including production of keV-scale sterile neutrinos as dark matter candidates, and dynamics of light eV-scale sterile neutrinos during the weakly-coupled active neutrino era. We review proposed signatures of light sterile neutrinos in cosmic microwave background and large scale structure data. We also discuss keV-scale sterile neutrino dark matter decay signatures in X-ray observations, including recent candidate ∼3.5 keV X-ray line detections consistent with the decay of a ∼7 keV sterile neutrino dark matter particle.

  2. [Regret of female sterilization].

    Science.gov (United States)

    Öhman, Malin Charlotta; Andersen, Lars Franch

    2015-11-16

    Regret of sterilization is inversely correlated to age at the time of sterilization. The minimum age for legal sterilization in Denmark has recently been lowered to 18 years. In Denmark surgical refertilization has almost completely been replaced by in vitro fertilization (IVF). In recent literature pregnancy results after surgical refertilization are easily comparable to IVF. Refertilization may in some cases be advantageous to IVF treatment. Women requesting reversal of sterilization should be offered individualized evaluation and differentiated treatment. It is recommended that surgical refertilization is performed at very few centres.

  3. Modular ionizing sterilizer (MIS)

    International Nuclear Information System (INIS)

    Freijo, Jose L.

    1999-01-01

    A transportable device designed to sterilize medical material and wastes by gamma irradiation is described. The sterilizer is formed by three modules: one of the modules contains the gamma source and can be removed to transport and transfer the source, the other modules are designed to introduce and draw out the materials to be irradiated

  4. [Sterilization and eugenics].

    Science.gov (United States)

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  5. Sterilization by Laparoscopy

    Science.gov (United States)

    ... If pregnancy does occur, the risk of an ectopic pregnancy is higher than in women who did not ... pregnant. Also, the risk of problems, such as ectopic pregnancy, is increased. What are some alternatives to sterilization? ...

  6. Sterilization by gamma irradiation

    International Nuclear Information System (INIS)

    Reyes Frias, L.

    1992-01-01

    Since 1980 the National Institute of Nuclear Research counts with an Industrial Gamma Irradiator, for the sterilization of raw materials and finished products. Through several means has been promoted the use of this technology as alternative to conventional methods of sterilization as well as steam treatment and ethylene oxide. As a result of the made promotion this irradiator has come to its saturation limit being the sterilization irradiation one of the main services that National Institute of Nuclear Research offers to producer enterprises of disposable materials of medical use also of raw materials for the elaboration of cosmetic products and pharmaceuticals as well as dehydrated foods. It is presented the trend to the sterilization service by irradiation showed by the compilation data in a survey made by potential customers. (Author)

  7. Sterilization of space hardware.

    Science.gov (United States)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  8. Contraception Update: Sterilization.

    Science.gov (United States)

    Antell, Karen; Deshmukh, Prium; Brown, Elizabeth J

    2017-11-01

    Female sterilization procedures include postpartum partial salpingectomy via cesarean or minilaparotomy incision, interval laparoscopic procedures, or hysteroscopic placement of microinserts. Rates of failure and serious complications are low and comparable among the various methods. A hysteroscopic procedure requires a 3-month confirmatory hysterosalpingogram before it is considered effective for contraception. Hysteroscopic sterilization has been shown to be associated with a higher reoperation rate than laparoscopic procedures. For male sterilization, vasectomy is a noninvasive and highly effective method. Vasectomy is an outpatient procedure performed under local anesthesia. The procedure requires confirmation of azoospermia with a semen analysis 8 to 16 weeks after the procedure. Patients who are considering sterilization should be counseled about all the available options and the permanent nature of such procedures. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  9. Auditing radiation sterilization facilities

    Science.gov (United States)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  10. Introduction to sterile neutrinos

    Science.gov (United States)

    Volkas, R. R.

    2002-07-01

    Model-building issues raised by the prospect of light sterile neutrinos are discussed in a pedagogical way. I first review the naive proposal that sterile neutrinos be identified with “right handed neutrinos”. A critical discussion of the simple expedient of adding three gauge singlet fermions to the usual minimal standard model matter content is followed by an examination of right handed neutrinos in extended theories. I introduce the terminology of “fully sterile” and “weakly sterile” to classify varieties usually conflated under the sterile neutrino banner. After introducing the concepts of “technical naturalness” and plain “naturalness”, the unbearable lightness of being a sterile neutrino is confronted. This problem is used to motivate mirror neutrinos, whose connection with pairwise maximal mixing is emphasised. Some brief remarks about phenomenology are made throughout. The impossibility of identifying the sole sterile neutrino of the currently favoured 2 + 2 and 3 + 1 phenomenological constructs as a lone gauge singlet fermion added to the minimal standard model is explained. Finally, I remark on the beauty and subtlety of light sterile neutrino cosmology.

  11. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  12. Hysteroscopic Tubal Sterilization

    Science.gov (United States)

    McMartin, K

    2013-01-01

    Background Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligation, potential advantages of the hysteroscopic procedure are that it can be performed in 10 minutes in an office setting without the use of general or even local anesthesia. Objective The objective of this analysis was to determine the effectiveness and safety of hysteroscopic tubal sterilization compared with tubal ligation for permanent female sterilization. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2008, until December 11, 2012. Review Methods Observational studies, randomized controlled trials (RCTs), systematic reviews and meta-analyses with 1 month or more of follow-up were examined. Outcomes included failure/pregnancy rates, adverse events, and patient satisfaction. Results No RCTs were identified. Two systematic reviews covered 22 observational studies of hysteroscopic sterilization. Only 1 (N = 93) of these 22 studies compared hysteroscopic sterilization to laparoscopic tubal ligation. Two other noncomparative case series not included in the systematic reviews were also identified. In the absence of comparative studies, data on tubal ligation were derived for this analysis from the CREST study, a large, multicentre, prospective, noncomparative observational study in the United States (GRADE low). Overall, hysteroscopic sterilization is associated with lower pregnancy rates and lower complication rates compared to tubal ligation. No deaths have been reported for hysteroscopic sterilization. Limitations A lack of long-term follow-up for hysteroscopic sterilization and a paucity of studies that directly

  13. Sterilization: A Review and Update.

    Science.gov (United States)

    Moss, Chailee; Isley, Michelle M

    2015-12-01

    Sterilization is a frequently used method of contraception. Female sterilization is performed 3 times more frequently than male sterilization, and it can be performed immediately postpartum or as an interval procedure. Methods include mechanical occlusion, coagulation, or tubal excision. Female sterilization can be performed using an abdominal approach, or via laparoscopy or hysteroscopy. When an abdominal approach or laparoscopy is used, sterilization occurs immediately. When hysteroscopy is used, tubal occlusion occurs over time, and additional testing is needed to confirm tubal occlusion. Comprehensive counseling about sterilization should include discussion about male sterilization (vasectomy) and long-acting reversible contraceptive methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Voluntary sterilization in Britain.

    Science.gov (United States)

    Jackson, L N

    1968-01-01

    Only recently has the value and importance of sterilization as an effective method of birth control come to be widely recognized in Britian. Credit for this recognition is largely due to the initiative of Dr. C. P. Blacker, chairman of the Simon Population Trust. The Trust's sterilization project was conceived by him and, heralded by an article in The Lancet on 30 April 1966, was launched at a press conference in London in May of that year. Since then the Project has gone from strength to strength. It first function was to make known how voluntary sterilization can help to solve or prevent family problems and to facilitate its practice in Britian. The project has also been concerned to correct the erroneous belief, still held by a dwindling number of medical and law persons, that sterilization is against the law. A prerequisite was to enlist cooperative surgeons all over the country, whose names are now being sent on request to family doctors wishing to refer men for sterilization. The project is concerned mainly with male, rather than female, sterilization. The reason for this is that, when the relative simplicity of vasectomy as compared with tubal ligation is explained to them most couples choose vasectomy. Information about sterilization is supplied not only to applicants but also to university and hospital authorities, surgeons, health and welfare workers, family planning clinics. Forms of consent are provided for the couple concerned, and a follow-up inquiry is being conducted on a substantial scale among men who have been sterilized through the agency of the Project. Though this inquiry is far from complete, replies so far received indicate almost universal satisfaction with the results of the operation. Indeed, with the fear of unwanted pregnancies removed, many couples report that marital harmony is increased. It is known that at least 2000 men have already been sterilized through the mediation of this Project and, as family doctors become increasingly

  15. Audits of radiation sterilization facilities

    International Nuclear Information System (INIS)

    Kelkar, Prabhakar M.

    2001-01-01

    Johnson and Johnson is the world leader in sterilization science and technology. A special group of scientists and technologists are engaged in the development of new methods of sterilization, worldwide monitoring of sterilization processes, equipment and approvals for all types of sterilization processes. Kilmer Conference in the alternate year for the benefit of all those involved in improvement in sterilization science is held. Cobalt-60 gamma radiation for sterilization of medical products on commercial scale is used. This kind of mammoth task can only be achieved through systematic method of planning, auditing, expert review and approval of facilities

  16. Heat sterilization of wood

    Science.gov (United States)

    Xiping Wang

    2010-01-01

    Two important questions should be considered in heat sterilizing solid wood materials: First, what temperature–time regime is required to kill a particular pest? Second, how much time is required to heat the center of any wood configuration to the kill temperature? The entomology research on the first question has facilitated the development of international standards...

  17. MINOS Sterile Neutrino Search

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, David Jason [Univ. College London, Bloomsbury (United Kingdom)

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  18. Sterilization of Native Americans

    Science.gov (United States)

    Dillingham, Brint

    1977-01-01

    The U.S. State Department's Agency for International Development (AID) is spending more than $143 million this year for population control measures in over 70 nations around the world and it is estimated that as much as $10 million was spent in one year for surgical sterilization procedures. (JC)

  19. Metody badania autofagii oparte na przemianach białek MAP1LC3 i p62/SQSTM1 

    Directory of Open Access Journals (Sweden)

    Edyta Wysokińska,

    2013-05-01

    Full Text Available Autofagia jest procesem katabolicznym o fundamentalnym znaczeniu dla przetrwania okresów niedoborów składników odżywczych i w recyklingu organelli komórkowych. W ostatnim czasie obserwuje się bardzo znaczący wzrost zainteresowania badaniem autofagii, a zaburzenia w jej przebiegu towarzyszą wielu chorobom. Niestety, warsztat jakim dysponujemy w badaniu autofagii pozostaje stosunkowo mało znany i ubogi. W pracy omówiono najczęściej stosowane metody badania autofagii. Oprócz mikroskopii elektronowej przedstawiono metody (fluorescencyjnei Western blotting oparte na obserwacji przemian białek MAP1LC3 i p62/SQSTM – należących do podstawowych markerów autofagii.

  20. 21 CFR 880.6850 - Sterilization wrap.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device...

  1. Sterile neutrino anarchy

    Science.gov (United States)

    Heeck, Julian; Rodejohann, Werner

    2013-02-01

    Lepton mixing, which requires physics beyond the Standard Model, is surprisingly compatible with a minimal, symmetryless and unbiased approach, called anarchy. This contrasts with highly involved flavor symmetry models. On the other hand, hints for light sterile neutrinos have emerged from a variety of independent experiments and observations. If confirmed, their existence would represent a groundbreaking discovery, calling for a theoretical interpretation. We discuss anarchy in the two-neutrino eV-scale seesaw framework. The distributions of mixing angles and masses according to anarchy are in agreement with global fits for the active and sterile neutrino parameters. Our minimal and economical scenario predicts the absence of neutrinoless double beta decay and one vanishing neutrino mass, and can therefore be tested in future experiments.

  2. Abortion and sterilization.

    Science.gov (United States)

    Steele, S J

    1970-01-01

    This discusses activities current in England under the abortion law of April 1968. In England and Wales in 1969 there were 54,013 recorded abortions and 15 related deaths. Since then both the number of deaths and the number of abortions have been increasing. This abortion increase is partly attributed to the adverse publicity regarding the pill which has caused many women to give up oral contraceptives. Complications have included incomplete removal of the products of conception, sepsis, hemorrhage, and perforation of the uterus. There have been wide variation in interpretations of the law by different hospitals and staffs. Sterilization operations are being done in increasing number for both men and women. Carefully worded consent forms are now in use to insure patient understanding and consent. Psychological changes may follow sterilization, but are relatively uncommon. Physicians should do all possible to help women avoid unwanted pregnancies and thereby reduce the demand for termination.

  3. Genetically conditioned male sterility

    International Nuclear Information System (INIS)

    Gottschalk, W.

    1976-01-01

    A survey is given of two different types of genetically controlled male sterility in higher plants. 'Functional' male sterility is due to the action of mutated genes causing a misdifferentiation of the growing points in different specific ways. Under the influence of the genes of this group either the stamens or the archespore tissues are not differentiated. In other mutants functionable male germ cells are produced but cannot be used for fertilizing the egg cells because the anthers remain closed or anthers and stigma become spatially separated from each other. Other genes of the group are responsible for the transformation of stamens into carpels, i.e. for a change of the hermaphrodite flower into a unisexually female one. A second type of male sterility is due to the action of ms genes influencing the course of micro-sporogenesis directly. They cause the breakdown of this process in a specific meiotic stage characteristic for each gene of the group. This breakdown is introduced by the degeneration of PMCs, microspores, or pollen grains preventing the production of male germ cells. The female sex organs remain uninfluenced. (author)

  4. Peroksīdu noteikšana ar eksprestestu metodi

    OpenAIRE

    Bruņeniece, Aiva

    2017-01-01

    Peroksīdu noteikšana ar eksprestestu metodi. Bruņeniece A., darba vadītājs Dr. ķīm. docents Ģībietis J. Bakalaura darbs, 44 lappuses, 10 tabulas, 26 attēli, 23 literatūras avoti. Latviešu valodā. Darbā apskatītas dažādas ūdeņraža peroksīda un peroksietiķskābes kvantitatīvās noteikšanas metodes. Veikta ITS firmas ekprestesta „Water-Works” teststrēmeļu kalibrēšana. Eksperimentāli izpētīta jonu spēka, pH un organiskā šķīdinātāja ietekme uz teststrēmeļu darbību. Iegūti kalibrēšanas grafiki un iz...

  5. Electron beam sterilization for dishes

    International Nuclear Information System (INIS)

    Deren, Wang; Meizhen, Fang

    1995-01-01

    Modern biological science often needs various fine strike devices which are often made from non-toxic transparent plastic. The application of high temperature steam to the sterilization as a traditional methods often causes deformation and colour change. When chemicals are applied to the sterilization residure of chemical grain often causes toxicity. Only application of radiation to the sterilization can overcome this faults and carry out with sterility assurance at room temperature. In this research 1.3 MeV electron beam coming from Model JJ-2 accelerator was applied for sterilization to 96-well tissue culture plates. After clean packaging the plates were irradiated with 31.7 XGy and operational voltage 1.3 MeV and 100 μA on the PY device. Repeated tests demonstrate that the products are sterile. The output is 2 x 10 5 pieces for each year. (author)

  6. Validation of radiation sterilization process

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    The standards for quality management systems recognize that, for certain processes used in manufacturing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product. Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of sterilization process is monitored routinely and the equipment is maintained according to ISO 13 485. Different aspects of this norm are presented

  7. Sterilization in the United States

    Science.gov (United States)

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  8. Sterilizing insects with ionizing radiation

    International Nuclear Information System (INIS)

    Bakri, A.; Mehta, K.; Lance, D.R.

    2005-01-01

    Exposure to ionizing radiation is currently the method of choice for rendering insects reproductively sterile for area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Gamma radiation from isotopic sources (cobalt-60 or caesium-137) is most often used, but high-energy electrons and X-rays are other practical options. Insect irradiation is safe and reliable when established safety and quality-assurance guidelines are followed. The key processing parameter is absorbed dose, which must be tightly controlled to ensure that treated insects are sufficiently sterile in their reproductive cells and yet able to compete for mates with wild insects. To that end, accurate dosimetry (measurement of absorbed dose) is critical. Irradiation data generated since the 1950s, covering over 300 arthropod species, indicate that the dose needed for sterilization of arthropods varies from less than 5 Gy for blaberid cockroaches to 300 Gy or more for some arctiid and pyralid moths. Factors such as oxygen level, and insect age and stage during irradiation, and many others, influence both the absorbed dose required for sterilization and the viability of irradiated insects. Consideration of these factors in the design of irradiation protocols can help to find a balance between the sterility and competitiveness of insects produced for programmes that release sterile insects. Many programmes apply 'precautionary' radiation doses to increase the security margin of sterilization, but this overdosing often lowers competitiveness to the point where the overall induced sterility in the wild population is reduced significantly. (author)

  9. Sterilization of Extracted Human Teeth.

    Science.gov (United States)

    Pantera, Eugene A., Jr.; Schuster, George S.

    1990-01-01

    At present, there is no specific recommendation for sterilization of extracted human teeth used in dental technique courses. The purpose of this study was to determine whether autoclaving would be effective in the sterilization of extracted teeth without compromising the characteristics that make their use in clinical simulations desirable. (MLW)

  10. Conditional sterility in plants

    Science.gov (United States)

    Meagher, Richard B.; McKinney, Elizabeth; Kim, Tehryung

    2010-02-23

    The present disclosure provides methods, recombinant DNA molecules, recombinant host cells containing the DNA molecules, and transgenic plant cells, plant tissue and plants which contain and express at least one antisense or interference RNA specific for a thiamine biosynthetic coding sequence or a thiamine binding protein or a thiamine-degrading protein, wherein the RNA or thiamine binding protein is expressed under the regulatory control of a transcription regulatory sequence which directs expression in male and/or female reproductive tissue. These transgenic plants are conditionally sterile; i.e., they are fertile only in the presence of exogenous thiamine. Such plants are especially appropriate for use in the seed industry or in the environment, for example, for use in revegetation of contaminated soils or phytoremediation, especially when those transgenic plants also contain and express one or more chimeric genes which confer resistance to contaminants.

  11. The Sterile Insect Technique

    International Nuclear Information System (INIS)

    Kiragu, J.

    2006-01-01

    Insect pests have caused an increasing problem in agriculture and human health through crop losses and disease transmission to man and livestock. Intervention to ensure food security and human health has relied on Integrated Pest Management (IPM) strategies to keep the pests population below economic injury levels. IPM integrate a variety of methods, but there has been over-reliance on chemical control following the discovery of insecticidal properties of DDT. It is now realized that, maintaining pest populations at controlled levels is unsustainable and eradication options is now being considered. Although the Sterile Insect Technique(SIT) could be used for insect suppression, it is gaining favour in the elimination (eradication) of the target pest population through Areawide-based IPM (Author)

  12. Ethylene Oxide Gaseous Sterilization

    Science.gov (United States)

    Ernst, Robert R.; Shull, James J.

    1962-01-01

    The duration of the equilibration period between admission of water vapor and subsequent introduction of gaseous ethylene oxide to an evacuated sterilizer chamber was studied with respect to its effect on the inactivation of spores of Bacillus subtilis var. niger under simulated practical conditions. Introduction of a water-adsorbing cotton barrier between the spores and an incoming gas mixture of water vapor and ethylene oxide caused a marked increase in the observed thermochemical death time of the spore populations. This effect was negated by admission of water vapor one or more minutes prior to introduction of ethylene oxide gas. Increases in temperature and relative humidity of the system promoted passage of water vapor through the cotton barriers and diminished their effect. PMID:13890660

  13. Thermalizing Sterile Neutrino Dark Matter

    Science.gov (United States)

    Hansen, Rasmus S. L.; Vogl, Stefan

    2017-12-01

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  14. Sterile Endophthalmitis after Intravitreal Injections

    Directory of Open Access Journals (Sweden)

    Joaquín Marticorena

    2012-01-01

    Full Text Available Sterile endophthalmitis appears as an infrequent complication of intravitreal injections and seems to develop mainly in the context of the off-label use of drugs that have not been conceived for intravitreous administration. The aetiology of sterile endophthalmitis, independently of the administered drug, remains uncertain and a multifactorial origin cannot be discarded. Sterile inflammation secondary both to intravitreal triamcinolone acetonide and to intravitreal bevacizumab share many characteristics such as the acute and painless vision loss present in the big majority of the cases. Dense vitreous opacity is a common factor, while anterior segment inflammation appears to be mild to moderate. In eyes with sterile endophthalmitis, visual acuity improves progressively as the intraocular inflammation reduces without any specific treatment. If by any chance the ophthalmologist is not convinced by the sterile origin of the inflammation, this complication must be treated as an acute endophthalmitis because of the devastating visual prognosis of this intraocular infection in the absence of therapy.

  15. Thermalizing Sterile Neutrino Dark Matter.

    Science.gov (United States)

    Hansen, Rasmus S L; Vogl, Stefan

    2017-12-22

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  16. Electrolytic silver ion cell sterilizes water supply

    Science.gov (United States)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  17. [Sterilization: necessity or genocide?].

    Science.gov (United States)

    Muraro, R M

    1991-01-01

    Recent warnings by the UN Fund for Population Activities about the rapid growth of the world population and the overwhelming role in it played by impoverished women in developing countries are of interest to all women in Latin America. According to the document, Third World Women require drastic improvements in their socioeconomic positions in order to achieve reductions in their family sizes and avoid an increase in the world population from 5 billion at present to 10 billion in 2025, which would be a disaster for the planet. The document states that much of the environmental damage that would occur would be attributable to the combination of poverty and rapid population increase. If the proportion of the world's women using contraceptives increases from the current 45% to 58% by the year 2000, the world population in 2025 will be 8.5 billion. The document recommends that the amount of money invested in family planning be greatly increased by 2000 in order to make possible increased use of family planning. It appears, however, that much of the funding for family planning is under the control of private organizations and is used to serve the interests of foreign countries. The 2 principal private family planning organizations in Brazil, for example, received 18.2 million US dollars between 1978--84, which were used largely to finance a campaign of mass sterilization. Brazil's rate of population growth, which was 2.1% in 1980-85 and 1.8% in 1990, is expected to drop to 1.6% in 1995. With the decline in the rate of growth, the population will be 170 million in 2000 instead of the 220 million projected using data from the 1970s. A much higher proportion of fertile-aged women in Brazil is sterilized than in the US or Europe . Closer examination of the premises behind family planning policies shows them to be questionable. The premise that population density affects the environment is questionable; Japan, West Germany, and Holland have some of the highest population

  18. Food irradiation and sterilization

    International Nuclear Information System (INIS)

    Josephson, E.S.

    1981-01-01

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25 to 70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning in achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70 to 80 0 C (bacon to 53 0 C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurrence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40 0 C to -20 0 C). Radappertized foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for 'wholesomeness' (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effects of radappertization on the 'wholesomeness' characteristics of these foods. (author)

  19. Food irradiation and sterilization

    Science.gov (United States)

    Josephson, Edward S.

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25-70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning is achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70-80°C (bacon to 53°C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40°C to -20°C). Radappertozed foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for "wholesomeness" (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effecys of radappertization on the "wholesomeness" characteristics of these foods.

  20. Documentation requirements for radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation for appr......Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation...... for approval of radiation sterilized products. The impact of these standards on the radiation sterilization is discussed, with special attention given to a few special issues, mainly traceability and uncertainty of measurement results....

  1. Sterile pyuria: a forgotten entity

    OpenAIRE

    Goonewardene, Sanchia; Persad, Raj

    2015-01-01

    Sterile pyuria is a common entity. Yet there are no guidelines to address this issue. We have conducted a systematic review over 20 years and reviewed the results. Guidelines for assessment, diagnosis and management are developed based on these results.

  2. Sterile pyuria: a forgotten entity.

    Science.gov (United States)

    Goonewardene, Sanchia; Persad, Raj

    2015-10-01

    Sterile pyuria is a common entity. Yet there are no guidelines to address this issue. We have conducted a systematic review over 20 years and reviewed the results. Guidelines for assessment, diagnosis and management are developed based on these results.

  3. Sterility assurance of medical products

    International Nuclear Information System (INIS)

    Dierksheide, W.C.

    1977-01-01

    The present methods of regulating medical devices under the Food, Drug and Cosmetic Act in the United States of America are outlined. Reference is made to the position of drugs sterilized by irradiation. Surgical sutures and surgical dressings are regulated as drugs. Some details are given of proposed changes in the Act. The subject is further discussed under the headings: sterility assurance, and biocompatibility. (U.K.)

  4. Food packaging and radiation sterilization

    International Nuclear Information System (INIS)

    Kawamura, Yoko

    1998-01-01

    Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The γ ray and an electron beam are commonly used in radiation sterilization. The γ ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing relatively thin materials and surface sterilization due to the weak transmission. A typical sterilization dose is approximately 10-30 kGy. Direct effects impacting packaging materials, particularly plastics, include scission of polymer links, cross-linkage between polymers, and generating radiolysis products such as hydrogen, methane, aliphatic hydrocarbons, etc. Furthermore, under the existence of oxygen, the oxygen radicals generated by the radiation will oxidize and peroxidize polymer chains and will generate alcohol and carbonyl groups, which shear polymer links, and generate oxygen containing low molecular compounds. As a result, degradation of physical strength such as elongation and seal strength, generating foreign odor, and an increase in global migration values shown in an elution test are sometimes evident. The food packages have different shapes, materials, additives, number of microorganisms and purpose. Therefor the effects of radiation, the optimum dose and so on must be investigated on the individual package. (J.P.N.)

  5. Radiation sterilization of skin allograft

    Science.gov (United States)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  6. Radiation sterilization of skin allograft

    International Nuclear Information System (INIS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-01-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6 . The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2 . The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  7. Radiation sterilization of buckwheat flour

    International Nuclear Information System (INIS)

    Ito, Hitoshi; Ishigaki, Isao; Muramatsu, Nobuyuki; Oohinata, Hiroshi; Ohara, Tadahiko; Oh-ike, Terui; Matsuhashi, Tetsujiro.

    1989-01-01

    For buckwheat noodle in which taste is important and its main material, buckwheat flour, the ordinary sterilization by heating or ozone cannot be applied. The number of the bacteria sticking to buckwheat flour is much more as compared with that of wheat flour, and is 10 5 -10 7 per 1 g. The effective countermeasures are not yet found. Also noxious insects are apt to infect buckwheat flour. It has been known that radiation is effective for the sterilization of flavorings. In this study, the microorganism contamination of buckwheat flour and sterilization dose, the change of taste and properties after irradiation, and the capability of storage were examined, and the results are reported. The bacteria in buckwheat flour were mostly Erwinia which forms yellow colonies, and is plant-parasitic bacteria having sugar fermentation function, and also some Enterobacer, Klebsiella and Aspergillus were found. When gamma ray was irradiated on buckwheat flour, it was sterilized to less than 10 3 per 1 g bacteria at the dose of 5 kGy, and microorganisms were almost sterilized at 10 kGy. With the electron beam of 3 MeV, the effect of sterilization somewhat decreased. The noodle-making property of irradiated buckwheat flour, and the taste and storage capability of the noodle of irradiated flour were tested. (K.I.)

  8. Genomic networks of hybrid sterility.

    Directory of Open Access Journals (Sweden)

    Leslie M Turner

    2014-02-01

    Full Text Available Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities". The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL. Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  9. Sterilization in Finland: from eugenics to contraception.

    Science.gov (United States)

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  10. Radiation: A means of sterilization

    International Nuclear Information System (INIS)

    Mukherjee, R.N.

    1975-01-01

    The sterilization of medical products by ionizing radiation is a well-established industrial process in a number of technologically advanced countries. It is indeed encouraging to note the rate of growth experienced during the past fifteen years. Starting with the first commercial plant in the early sixties in the USA there are to date more than sixty large facilities of this kind located in USA, Canada, Australia and the countries of Europe including USSR. The geographical distribution of these sterilization plants is rather unbalanced. In this respect Europe is far ahead of the other continents of the world, with about 65% of all sterilization plants, followed by North and South America with 17%, Asia with 8%, Australia and New Zealand with 9% and Africa with only 1%. During the last 10 years the IAEA has actively contributed to the development of radiation sterilization practices and technology in the Member States, with particular emphasis on the developing countries. Such promotional efforts have been made by (a) supporting co-ordinated research to accumulate relevant technical information, (b) organizing scientific meetings and training courses, (c) providing technical expertise in the form of fellowships and expert services, (d) providing technical assistance to conduct market surveys and economic feasibility assessment, (e) scientific publications, including technical manuals and proceedings reports, and (f) assistance in the formulation of an international 'Code of Practice' for standardization of the manufacturing practices for radiation sterilized medical products to meet the specified requirements of the various national Pharmacopoeias and of the international consumer market

  11. Sterilization of mentally retarded persons.

    Science.gov (United States)

    Van der Merwe, J V; Roux, J P

    1987-08-01

    South Africa's Abortion and Sterilization Act No 2 (1975) authorizes sterilization for severely retarded women provided the procedure is performed in a state hospital, certified by 2 medical practitioners (1 a psychiatrist), and the parent or guardian gives informed consent. Since 1975, 152 sterilizations (140 female, 12 male) have been performed under the provisions of this Act at Pretoria's H F Verwoerd Hospital. 92% of the patients were under 20 years of age. The majority were classified as profoundly or severely retarded (74) or moderately severely retarded (68). There were 20 patients with Down's syndrome and 22 with cerebral palsy. Hysterectomy was the method of choice in the 109 women in whom menstrual hygiene was a pertinent factor; the remaining 31 women were sterilized by tubal ligation. 98% of the parents or guardians of hysterectomy acceptors surveyed were satisfied with their decision and its outcome. Several indicated their daughter was more calm, cooperative, productive, and less irritable once relieved of her menstrual periods. A multidisciplinary team approach to the decision making process and the individualization of each case are essential to protect the rights of the mentally retarded. Factors such as the psychological trauma likely to result from pregnancy and childbirth, an inability to use contraception, and unsuitability to rear a child must be demonstrated. To ensure that legislation pertaining to the sterilization of the mentally retarded does not lead to abuse, inputs from the mental health professions are required.

  12. Neutrinos in a Sterile Throat

    CERN Document Server

    Gripaios, Ben Matthew

    2007-01-01

    We consider field-theoretic models of a warped extra dimension with multiple throats, in which fermions that are singlets of the Standard Model gauge group propagate in a separate throat from the Standard Model fields, which we call the sterile throat. The singlets mix with Standard Model fields via interactions localized on the UV brane that connects the two throats. This leads to three, light, mostly-active, Majorana neutrinos via a higher-dimensional see-saw mechanism, together with Kaluza-Klein towers of mostly-sterile neutrinos, whose scale is set by the warp factor in the sterile throat and can be very low if the throat is deep. We suggest that a model of this kind may explain all the neutrino data, reconciling the LSND result with astrophysical constraints.

  13. Radiation sterilization of hydrocortisone acetate

    International Nuclear Information System (INIS)

    Charef, A.; Boussaha, A.

    1989-09-01

    The feasibility of using high energy ionizing radiation for the sterilization of hydrocortisone acetate was investigated. Hydrocortisone acetate in the form of powder was exposed to different dose levels of gamma radiation using a Cobalt-60 source. The irradiated samples were examined by various physico-chemical techniques in order to detect possible radiolysis products. It was of interest to know if one could insure sterility and retain biological properties of the drug by suitable choice of radiation dose. The results showed that a 10 KGy radiation dose causes no change in the physico-chemical properties of the drug and is sufficient to obtain contaminant-free product

  14. Infezione sperimentale di capre con un ceppo atipico di Mycoplasma mycoides subsp. capri isolato in Giordania: confronto tra differenti metodi diagnostici

    OpenAIRE

    Massimo Scacchia; Robin A.J. Nicholas; Chiara De Caro; Flavio Sacchini; Gabriella Di Francesco; Andrea Di Provvido; Anna Rita D’Angelo

    2010-01-01

    Sono state infettate sperimentalmente 10 capre con un micoplasma identificato con metodi biomolecolari come Mycoplasma mycoides subsp. capri, ceppo Irbid, isolato da capre in un focolaio di agalassia contagiosa nel nord della Giordania e definito atipico per la sua peculiarità sierologica. Due gruppi di animali infettati rispettivamente per via endotracheale e aerosol sono stati posti in contatto con un terzo gruppo di capre. A sei settimane dall’infezione alcuni animali, sia infettati sia po...

  15. Transgenic technologies to induce sterility

    Directory of Open Access Journals (Sweden)

    Wimmer Ernst A

    2009-11-01

    Full Text Available Abstract The last few years have witnessed a considerable expansion in the number of tools available to perform molecular and genetic studies on the genome of Anopheles mosquitoes, the vectors of human malaria. As a consequence, knowledge of aspects of the biology of mosquitoes, such as immunity, reproduction and behaviour, that are relevant to their ability to transmit disease is rapidly increasing, and could be translated into concrete benefits for malaria control strategies. Amongst the most important scientific advances, the development of transgenic technologies for Anopheles mosquitoes provides a crucial opportunity to improve current vector control measures or design novel ones. In particular, the use of genetic modification of the mosquito genome could provide for a more effective deployment of the sterile insect technique (SIT against vector populations in the field. Currently, SIT relies on the release of radiation sterilized males, which compete with wild males for mating with wild females. The induction of sterility in males through the genetic manipulation of the mosquito genome, already achieved in a number of other insect species, could eliminate the need for radiation and increase the efficiency of SIT-based strategies. This paper provides an overview of the mechanisms already in use for inducing sterility by transgenesis in Drosophila and other insects, and speculates on possible ways to apply similar approaches to Anopheles mosquitoes.

  16. Sterile neutrino constraints from cosmology

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, Georg G.

    2012-01-01

    The presence of light particles beyond the standard model's three neutrino species can profoundly impact the physics of decoupling and primordial nucleosynthesis. I review the observational signatures of extra light species, present constraints from recent data, and discuss the implications of po...... of possible sterile neutrinos with O(eV)-masses for cosmology....

  17. Establishment of a sterilization dose

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    Factors that impact on product bioburden (population of diable microorganisms on or in product and/or sterile barrier system) are: Raw materials, components, product design and size, manufacturing process, manufacturing equipment, manufacturing environment and manufacturing location. Presented lecture describes all these factors in details

  18. Sterile Neutrino Search with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Devan, Alena V. [College of William and Mary, Williamsburg, VA (United States)

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  19. Sterilization In Protective Trade Policies

    OpenAIRE

    寺崎, 克志; Katsushi, Terasaki; 経営学部経営学科

    2007-01-01

    Under a government budget constraint export subsidies automatically sterilize distortions caused by import tariffs, i.e., without the cost of the trade policy implementation the policy mix of export subsidies and import tariffs with budget constraint makes the economy effective.

  20. Radiation sterilization: an industrial process

    International Nuclear Information System (INIS)

    Ley, F.J.

    1975-01-01

    A new dimension has been added to the use of radiation in the medical field with the introduction of radiation as a sterilizing agent. Its use in diagnosis through radioactive tracers or X-rays and in therapy administered with the most sophisticated of electrical machines or radioisotope units, is familiar in the hospital world, being well established therein. In contrast, the application of radiation sterilization is in industry where the installation of large radiation sources is already commonplace in many countries. The beginnings in the early 1950's centered on the Van de Graaff machine and linear accelerators and the pioneering efforts of Ethicon Inc. here in the United States must be recognized. However, although sterilization with electron beams is still current practice in a number of plants, the use of gamma rays from cobalt-60 is preferred. The first steps in this direction were taken by the U.K.A.E.A. which, in common with similar organizations elsewhere, was attempting to exploit the tremendous potential for cobalt-60 production arising through the rapid construction of nuclear reactors. The first full-scale commercial gamma plant was commissioned in the U.K. in 1960. It reached a loading of 500,000 curies before its demolition after twelve years of operation. The process gained rapid acceptance within industry and approval by health authorities because it provided a ''cold'' sterilization method combining the property of lethal effect with penetration. Its immediate impact occurred in the introduction of disposable products making it possible, for example, to use heat-labile plastics and new packaging materials and package designs. Certainly, the technique has proved complementary to sterilization methods based on heat and to the use of chemical agents, in particular ethylene oxide gas

  1. 45 CFR 96.73 - Sterilization.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  2. Reversal of sterilization by microsurgical technique.

    Science.gov (United States)

    Gaspari, A L; Ortensi, A; Parlangeli, V; Pellizzari, G; Setti, C; Lania, M

    1988-01-01

    Tubal sterilization techniques that spare the fimbriae and cause the least amount of tubal destruction offer the best chance for reversal of sterilization. Patients seeking reversal of sterilization should be carefully selected. Surgical technique and equipment are important factors in reversal procedures; microsurgical techniques are shown to be more effective than macroscopic techniques.

  3. Radiosterilization or sterilization by steam. Procedures for sterilization of spices

    International Nuclear Information System (INIS)

    Warmbold, J.

    1994-01-01

    The article compares two different methods for the sterilization of spices, namely radiosterilization and sterilization with steam. The first method applies ionizing radiation which can alter the chemical composition of the products. Tests have shown, however, that radiation doses up to 10 kGy will not induce the formation of carcinogenic agents in the foodstuffs, or of toxic substances, and thus are a wholesome method of preservation. Any modifications of taste, color or smell, or loss of vitamins, can be avoided by proper dose control and standard irradiation conditions. Sterilization by steam is a method achieving substantial suppression of the formation of germs, aerobic spores, yeasts, mould, and gramnegative germs, while preserving in most cases the essential oils. It may result in sensoric alterations, i.e affect the color, smell or taste, but in general the spices thus treated preserved their characteristic properties. The method is a good alternative to radiosterilization. The article adds some concluding information on mandatory labelling of irradiated food imported from third countries

  4. Microwave Sterilization and Depyrogenation System

    Science.gov (United States)

    Akse, James R.; Dahl, Roger W.; Wheeler, Richard R., Jr.

    2009-01-01

    A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time

  5. Methods of censusing Red fox (Vulpes vulpes populations / Metodi di censimento della Volpe (Vulpes vulpes

    Directory of Open Access Journals (Sweden)

    Juan Francisco Beltrán

    1991-07-01

    Full Text Available Abstract Estimating absolute or relative numbers in red fox populations is not an easy task. Although a range of methods has been described, neither an optimal nor a universally accepted technique has been found. Moreover, none has been tested on populations of known size. We reviewed the efficiency of fourteen indices of fox abundance classified into two groups: (a methods where individuals are captured and marked, which include ear tagging or similar conspicuous markings, toe clipping, radioactive tagging of faeces, radio-tracking, and statistics from hunting and trapping; (b methods not requiring capture, which include both direct methods (nocturnal counts, unsystematic observations, and drive censuses, and indirect methods (den counts, transects for track, scat counts, and scent stations. As a rule, statistics are rarely applicable to populations estimates. Methods involving capture are expensive but provide more accurate estimates than the second group of indices, which are not suitable for paired comparisons from one year to another. Management and wildlife specialists should have in mind such restrictions when considering their goals and the required level of accuracy. Finally, we recommend the simultaneous utilization and comparison of several methods (one from each group, as proposed in a double sampling strategy for optimum evaluations. Riassunto La valutazione della consistenza di una popolazione di Volpe, mediante censimenti assoluti o relativi, è di difficile soluzione. Tra i diversi metodi di conteggio impiegati, nessuno si è rivelato ottimale e universale. Tuttavia nessuno è stato utilizzato per popolazioni di consistenza nota. Qui esaminiamo la validità di 14 metodi impiegati per il calcolo di indici di abbondanza, ripartendoli in due gruppi: (a metodi che implicano la cattura e il marcamento degli animali mediante marche auricolari o contrassegni similari, amputazione delle falangi

  6. Aplikace plné metody konsolidace dle české účetní legislativy a IFRS

    OpenAIRE

    Kabeláková, Simona

    2015-01-01

    Tato diplomová práce se zabývá plnou metodou konsolidace dle české účetní legislativy a dle IFRS. Teoretická část je věnována významu a právní úpravě konsolidované účetní závěrky, základním pojmům jako je míra vlivu, konsolidační celek nebo mateřský podnik, a také jednotlivým metodám konsolidace, především plné metodě. Praktická část je zaměřena na praktickou aplikaci plné metody konsolidace v podmínkách společnosti TESLA Holding a.s. a jejich dceřiných společností v letech 2007 - 2012. Th...

  7. Návrh změny metody konsolidace u vybraného konsolidovaného celku

    OpenAIRE

    Čadová, Michaela

    2017-01-01

    Téma diplomové práce je konsolidace účetní závěrky. Práce obsahuje teoretická východiska, která se týkají problematiky konsolidace účetní závěrky, a tyto poznatky jsou potom zúročeny v části praktické. Analytická část se zaobírá zhodnocením současného stavu, obsahuje tedy původní konsolidaci účetní závěrky zvolené společnosti. V návrhové části je aplikována nová metoda konsolidace účetní závěrky. Následně je zhodnocen dopad změny konsolidační metody na ekonomickou situaci konsolidačního celku...

  8. Aplikace metody Fused Deposition Modeling pro vyhotovení návrhu modelu planetového mechanismu

    OpenAIRE

    Kudláčová, Barbora

    2015-01-01

    Tato bakalářská práce má za cíl pojednat o návrhu a konstrukci modelu planetového me-chanismu s využitím technologie rapidního prototypování. Virtuální model byl vytvořen v parametrickém programu SolidWorks 2013 a vytištěn 3D tiskárnou Dimension uPrint, jež pro zhotovení využívá metodu Fused Deposition Modeling. Součástí práce je vysvětlení planetového mechanismu po stránce teoretické, praktické a rovněž konstrukční a dále popis metody Fused Deposition Modeling. Model planetového mechanismu a...

  9. Sterility of the uterine cavity

    DEFF Research Database (Denmark)

    Møller, Birger R.; Kristiansen, Frank V.; Thorsen, Poul

    1995-01-01

    In a prospective open study the sterility of the uterine cavity was evaluated in 99 women admitted for hysterectomy. The indications for hysterectomy were in most cases persistent irregular vaginal bleeding and fibromyomas of the uterus. Samples for both aerobic and anaerobic bacteria, Chlamydia ...... which may play a causative role in endometritis. The results indicate that inflammation of the uterine cavity should be evaluated by hysteroscopic examination before hysterectomy is undertaken in patients with persistent irregular vaginal bleeding. Udgivelsesdato: 1995-Mar...

  10. Signature of heavy sterile neutrinos at CEPC

    Science.gov (United States)

    Liao, Wei; Wu, Xiao-Hong

    2018-03-01

    We study the production of heavy sterile neutrino N , e+e-→N ν (ν ¯), at the Circular Electron Positron Collider (CEPC) and its l j j signal in its decay to three charged fermions. We study background events for this process which are mainly events coming from W pair production. We study the production of a single heavy sterile neutrino and the sensitivity of CEPC to the mixing of the sterile neutrino with active neutrinos. We study the production of two degenerate heavy sterile neutrinos in a low energy seesaw model by taking into account the constraints on mixings of sterile neutrinos from the neutrinoless double β decay experiment and the masses and mixings of active neutrinos. We show that CEPC under proposal has a good sensitivity to the mixing of sterile neutrinos with active neutrinos for a mass of a sterile neutrino around 100 GeV.

  11. Sterile Neutrinos in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Benjamin J.P. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  12. Plasma Sterilization: New Epoch in Medical Textiles

    Science.gov (United States)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  13. Women plan condom use after sterilization.

    Science.gov (United States)

    1998-12-01

    Sexual sterilization is highly effective in preventing pregnancy, but it does not protect against sexually transmitted diseases (STDs). People who accept sterilization as their method of family planning therefore need to be encouraged to protect themselves against HIV/AIDS and STDs even after they have been sterilized. Since women return less often to family planning providers following their sterilization procedure, they need to be advised to protect themselves against HIV and STDs before the sterilization is performed. 42% of the 2782 women who underwent tubal sterilizations at the Baylor College of Medicine in Houston during 1991-96 indicated their intention in a cross-sectional study to use condoms after sterilization. 20% of all respondents, aged 18-51 years, had a known risk factor for HIV, and almost 25% reported regular condom use for contraception or disease protection during the 3 months before sterilization. Planned condom use increased from 32% in 1991 to 51% in 1996, irrespective of age, marital status, or ethnic background. Of the 646 women who used condoms before being sterilized, almost half indicated no plans to do so after the procedure. The following factors were associated with condom use: relatively younger age, black ethnicity, unmarried status, history of previous STD, no steady partner, having a higher number of previous sex partners, past use of condoms to prevent disease transmission, and lack of partner involvement in the decision to undergo sterilization.

  14. Regret following female sterilization in Slovenia.

    Science.gov (United States)

    Becner, Anja; Turkanović, Anela Bečić; But, Igor

    2015-07-01

    To estimate the regret rate and risk factors for regret among women who have undergone sterilization. A retrospective study was conducted among all women who underwent a sterilization procedure at the University Medical Center Maribor, Maribor, Slovenia, in 2008-2012. Identified women were contacted and asked to complete an online questionnaire assessing regret and symptoms associated with depression. Among 714 identified women, 308 (43.1%) completed the questionnaire. Four (1.3%) participants reported regret, and 9 (2.9%) reported that they would not opt for sterilization again, all of whom had post-sterilization problems. Such problems were significantly associated with participants reporting that they would not opt for sterilization again (P=0.003). Additionally, women who would not choose sterilization again had significantly higher scores on the depressive scale used than did those who would undergo sterilization again (P=0.028). Few women report regret after tubal sterilization in Slovenia. However, an additional consultation on post-sterilization problems and depressive disorder before sterilization might minimize the risk of regret. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  15. Experimental bounds on sterile neutrino mixing angles

    CERN Document Server

    Ruchayskiy, Oleg

    2012-01-01

    We derive bounds on the mixing between the left-chiral ("active") and the right-chiral ("sterile") neutrinos, provided from the combination of neutrino oscillation data and direct experimental searches for sterile neutrinos. We demonstrate that the mixing of sterile neutrinos with any flavour can be significantly suppressed, provided that the angle theta_13 is non-zero. This means that the lower bounds on sterile neutrino lifetime, coming from the negative results of direct experimental searches can be relaxed (by as much as the order of magnitude at some masses). We also demonstrate that the results of the negative searches of sterile neutrinos with PS191 and CHARM experiments are not applicable directly to the see-saw models. The reinterpretation of these results provides up to the order of magnitude stronger bounds on sterile neutrino lifetime than previously discussed in the literature. We discuss the implications of our results for the Neutrino Minimal Standard Model (the NuMSM).

  16. Birth planning and sterilization in China.

    Science.gov (United States)

    Short, S E; Linmao, M; Wentao, Y

    2000-11-01

    Sterilization is the most prevalent method of contraception in China. Approximately half of all women of reproductive age report that they or their husbands are sterilized. Using data from the China Health and Nutrition Survey we describe patterns of sterilization in eight Chinese provinces. With a discrete-time event history model we investigate the link between characteristics of local birth planning policy and the risk of sterilization. After controlling for parity, the risk of sterilization is highest in communities where birth planning policy is least strong as measured by exceptions to the one-child policy. These results suggest that couples with more flexibility in family building may have less control over contraceptive method use. Other factors affecting the risk of sterilization are a woman's age, parity, and whether or not she has a son. Our results emphasize the importance of taking into account multiple dimensions of reproductive behaviour when assessing one-child policy changes.

  17. Surgical Sterilization, Regret, and Race: Contemporary Patterns*

    Science.gov (United States)

    Shreffler, Karina M.; McQuillan, Julia; Greil, Arthur L.; Johnson, David R.

    2014-01-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4,609 women ages 25 to 45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. PMID:25592919

  18. Surgical sterilization, regret, and race: contemporary patterns.

    Science.gov (United States)

    Shreffler, Karina M; McQuillan, Julia; Greil, Arthur L; Johnson, David R

    2015-03-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4592 women ages 25-45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. EB surface sterilization of food material

    International Nuclear Information System (INIS)

    Kaneko, H.; Mizutani, A.; Kato, K.; Nishikimi, T.; Taniguchi, S.

    2001-01-01

    In this paper, we introduce a food irradiation with low energetic, lower than 300keV, electrons (so-called SOFT ELECTRON) as a rather new method of food sterilization. It is also a physical sterilization method, and free from the problems mentioned above. Low energetic electrons have small penetration power (50-200micron) through raw materials, and by selecting a proper energy of electrons we can sterilize only the surfaces or skins of target materials

  20. Kultura organizacyjna jako determinanta efektywnego zarządzania wiedzą w zespołach projektowych wykorzystujących metody zwinne

    OpenAIRE

    Paterek, Paweł

    2016-01-01

    Cyfryzacja, powszechny dostęp do informacji oraz silna konkurencyjność stawiają nowe wyzwania w obszarze zarządzania wiedzą w dużych organizacjach projektowo-zadaniowych. Artykuł pokazuje znacznie kultury organizacyjnej w zapewnieniu efektywności procesów zarządzania wiedzą w zespołach projektowych wykorzystujących zwinne metody organizacji pracy. Przeprowadzone badania ankietowe, obserwacje oraz wywiady z ekspertami potwierdziły znaczenie kultury organizacyjnej oraz pokazały jej pożądane cec...

  1. Sterilization of oils: Data to support the use of a continuous point-of-use sterilizer.

    Science.gov (United States)

    Bader, F G; Boekeloo, M K; Graham, H E; Cagle, J W

    1984-08-01

    The continuous slow feed of animal and vegetable oils is frequently found to be an economically attractive method for maintaining antibiotic fermentations at a highly productive rate. The sterilization of oil feeds can present a major problem in the production plant. In this article, we present data and methodology on the kinetics of the thermal sterilization of No. 2 lard oil and soybean oil. It was also determined that dry heat sterilization condition could occur if dry spores were added to dry oil. This condition could only be partially alleviated by the addition of water to the oil. The theory and design of a small tubular coil continuous sterilizer for sterilizing oils at the point of use is also presented. This type of sterilizer is economical and versatile and simplifies control and instrument requirements. It provides a realistic alternative to the use of sterile feed tanks and sterile headers.

  2. Probabilistic model for sterilization of food

    International Nuclear Information System (INIS)

    Chepurko, V.V.; Malinovskij, O.V.

    1986-01-01

    The probabilistic model for radiation sterilization is proposed based on the followng suppositions: (1) initial contamination of a volume unit of the sterilized product m is described by the distribution of the probabilities q(m), (2) inactivation of the population from m of microorganisms is approximated by Bernoulli test scheme, and (3) contamination of unit of the sterilized product is independent. The possibility of approximation q(m) by Poisson distribution is demonstrated. The diagrams are presented permitting to evaluate the dose which provides the defined reliability of sterilization of food for chicken-gnotobionts

  3. Cryoradiation sterilization - contemporary state and outlook

    International Nuclear Information System (INIS)

    Talrose, V.L.

    1995-01-01

    The new approach of radiation sterilization -cryoradiosterilization with programmed freezing - was developed for pharmaceutical solutions. Both scientific and technical problems are solved, the results are discussed. Programmed freezing of vials with the drug's solutions provides the high stability of soluted components with biological activity at sterilizing irradiation without significant change of sterilization doses. Physical, chemical, biological and pharmacological properties of a lot of drug solutions for injection satisfy official requirements after cryoradiation sterilization treatment. This method seems to be especially important for the protein systems which could be infected by dangerous viruses (VIH, hepatitis B): blood plasma, diagnostic sera, protein preparations manufactured from donor's blood, etc. (Author)

  4. Currently available devices for female sterilization.

    Science.gov (United States)

    Chapman, Lynne; Magos, Adam

    2005-09-01

    Sterilization is now the method of family planning most commonly used in the world. Over the last 150 years, research has evolved in the search for the ideal method of female sterilization. The procedure should ideally have high efficacy, be readily accessible and be personally and culturally acceptable. The method should be simple, quick, easily learned and be able to be performed in an outpatient setting without general anesthesia. The most common and effective method for sterilization has, thus far, been via the laparoscopic route. Hysteroscopic sterilization, however, potentially fulfills many of these ideal criteria, but until recently has remained more of a concept than a reality.

  5. Sterile neutrino dark matter with supersymmetry

    Science.gov (United States)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  6. Seeking sterile neutrinos in Finslerian cosmology

    Science.gov (United States)

    Wang, Deng; Meng, Xin-He

    2017-11-01

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H_0 tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N_eff=3.237^{+0.092}_{-0.185}, which is consistent with Δ N_eff > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N_eff=3.143^{+0.064}_{-0.066}, which favors Δ N_eff > 0 at the 1.47σ CL, and m_{ν , sterile}^eff sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration.

  7. Analysis of Soft Soil Consolidation with the Application of Prefabricated Vertical Drains with Preloading Method Using Fem / Analiza Konsolidacji Słabych Gruntów Przy Uzyciu Metody Elementów Skonczonych

    Directory of Open Access Journals (Sweden)

    Binder K.

    2011-03-01

    Full Text Available W artykule przedstawiono zastosowanie metody elementów skonczonych przy przewidywaniu osiadan nasypów drogowych posadowionych na podłozu wzmacnianym przy uzyciu nasypu przeciazajacego i drenazu pionowego. Idea metody było przejscie z analitycznego rozwiazania jednowymiarowej konsolidacji do rozwiazania w Płaskim Stanie Odkształcenia z zachowaniem ekwiwalentnego czasu konsolidacji oraz porównanie z wynikami uzyskanymi z bezposrednich pomiarów osiadan nasypu drogowego bedacego czescia Obwodnicy Południowej Gdanska, zlokalizowanego w okolicach miejscowosci Przejazdowo.

  8. Light Sterile Neutrinos: A White Paper

    DEFF Research Database (Denmark)

    Abazajian, K. N.; Acero, M. A.; Agarwalla, S. K.

    2012-01-01

    This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.......This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data....

  9. Sodium hypochlorite sterilization of culture medium in ...

    African Journals Online (AJOL)

    With the purpose of finding an alternative to thermal sterilization, this research aimed at assessing the efficiency and ideal concentration of sodium hypochlorite for sterilization of culture media and glassware used during rooting of micropropagated Gerbera hybrida cv. Essandre. Two experiments were carried out. In the first ...

  10. Guidelines for pre-sterilization counseling.

    Science.gov (United States)

    1996-09-01

    The following guidelines for pre-sterilization counseling have been adopted by the Association for Voluntary Surgical Contraception: 1) emphasize that sterilization is permanent; 2) involve both partners in the decision making and present male sterilization as a viable option; 3) even if sterilization is requested, also present the range of long-term reversible methods available; 4) inform the client of failure rates associated with female sterilization and the associated risk of ectopic pregnancy; 5) emphasize that sterilization provides no protection against sexually transmitted diseases, including human immunodeficiency virus; 6) screen candidates for risk factors of post-sterilization regret, including young age and sterilization at the time of abortion or delivery; 7) fully explain the surgical procedure, preoperative instructions, surgical site, timing of the procedure, type of anesthesia, surgical risks, and length of recovery; 8) describe the possibility of unrelated changes in menstruation; 9) answer all questions; 10) discuss the positive effects on sexuality once concerns about unwanted pregnancy are removed; and 11) provide printed educational materials that the couple can review privately.

  11. Cosmology seeking friendship with sterile neutrinos

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, G.G.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile...

  12. Iran eases limits on sterilization.

    Science.gov (United States)

    Roudi, N

    1991-03-01

    The government of Iran announced in November 1990, in an abrupt reversal of previous policies, the legislation of sterilization and its provision free-of-charge upon request, as well as the distribution of other contraceptive gratis. At the time of the Islamic Revolution in 1979 the government adopted a pronatalist policy, family planning programs were interrupted, legal ages of marriage were lowered, and barriers against polygamy were loosened. Iran had a 3.5% growth rate in 1990 and a total fertility rate of 6.3 lifetime births/woman. After the end of the war between Iran and Iraq in 1988, the population explosion became an obstacle to reconstruction. In 1950, the population numbered 14.2 million; by 1970 it had doubled to 28.4 million. In 1990, the country had 54.6 million people. According to a 1990 UN assessment the population will soar to 100 million by 2020. Over 8 million live in Tehran where overcrowding, traffic congestion, air pollution, and high living costs are the norm. the 1989 National Birth Control Policy Summary adopted targets to reduce the average number of lifetime births per woman to 4 children and natural growth rate to 2.3% by 2011, and to provide family planning to 24% of reproductive-age women whereby 1 million conceptions would be prevented. Indirect measures to curb fertility include raising literacy promoting the education of girls, improving the status and health conditions of women, and reducing maternal and child mortality. A media campaign has started to encourage a small family model. The low legal, social, educational, and employment status of women poses obstacles to this plan, however, the revision of laws that conflict with these goals has been urged. In other Islamic countries such as Turkey, Tunisia, Indonesia, Pakistan, and Bangladesh, female sterilization is legal. Abortion in Iran remains banned except for saving the life of the mother.

  13. Federally funded sterilization: time to rethink policy?

    Science.gov (United States)

    Borrero, Sonya; Zite, Nikki; Creinin, Mitchell D

    2012-10-01

    In the 1970s, concern about coercive sterilization of low-income and minority women in the United States led the US Department of Health, Education, and Welfare to create strict regulations for federally funded sterilization procedures. Although these policies were instituted to secure informed consent and protect women from involuntary sterilization, there are significant data indicating that these policies may not, in fact, ensure that consent is truly informed and, further, may prevent many low-income women from getting a desired sterilization procedure. Given the alarmingly high rates of unintended pregnancy in the United States, especially among low-income populations, we feel that restrictive federal sterilization policies should be reexamined and modified to simultaneously ensure informed decision-making and honor women's reproductive choices.

  14. Metody badania spontanicznych i spowodowanych lekami przeciwpsychotycznymi zaburzeń ruchowych w schizofrenii

    Directory of Open Access Journals (Sweden)

    Olga Kałużyńska

    2013-09-01

    Full Text Available Od dawna wiadomo, że przynajmniej niektóre zaburzenia motoryczne występują u chorych na schizofrenię jeszcze przed podjęciem leczenia lekami przeciwpsychotycznymi istotnie statystycznie częściej niż w populacji ogólnej. Wpro‑ wadzenie leków przeciwpsychotycznych zahamowało jednak ten nurt badań, bowiem od tej pory koncentrowano się wyłącznie na objawach zaburzeń ruchowych powstałych w wyniku stosowania neuroleptyków. W kilku pracach wy‑ kazano również, że niektóre zaburzenia ruchowe są częstsze i bardziej nasilone u krewnych I stopnia osób chorych, lecz rzadsze i mniej nasilone niż u chorych na schizofrenię. Obecnie istnieje wiele narzędzi – skal klinicznych, używa‑ nych w praktyce i badaniach, opartych na obserwacji klinicznej, służących do oceny występowania i nasilenia zabu‑ rzeń motorycznych zarówno spontanicznych, jak i związanych z leczeniem lekami przeciwpsychotycznymi. Najczęściej przy pomocy tych skal ocenia się i monitoruje objawy parkinsonizmu, dystonie oraz akatyzję. Uważa się, że wszyst‑ kie te narzędzia mają jednak wiele wad i nie pozwalają na wykrycie i obiektywny pomiar subklinicznych objawów za‑ burzeń motorycznych. Instrumentalne metody oceny zaburzeń ruchowych (spontanicznych i spowodowanych leka‑ mi przeciwpsychotycznymi pozwalają na wykrycie właśnie subtelnych, słabo nasilonych objawów i dlatego mogą być przydatne przy identyfikacji osób z tzw. stanem wysokiego ryzyka rozwoju psychozy, ocenie występowania dysfunkcji motorycznych u krewnych osób chorych na schizofrenię, a także określaniu stopnia i rodzaju odpowiedzi na leczenie lekami przeciwpsychotycznymi. Większość tych metod wymaga jednak skomplikowanej aparatury i procedury analizy uzyskanych wyników. Jedną z interesujących i stosunkowo łatwych do realizacji metod instrumentalnych wydaje się wieloaspektowa ocena pisma. Zastosowanie nowych metod oceny zaburzeń motorycznych konieczne

  15. Seeking sterile neutrinos in Finslerian cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Deng [Nankai University, Theoretical Physics Division, Chern Institute of Mathematics, Tianjin (China); Meng, Xin-He [Nankai University, Department of Physics, Tianjin (China)

    2017-11-15

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H{sub 0} tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N{sub eff} = 3.237{sup +0.092}{sub -0.185}, which is consistent with ΔN{sub eff} > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N{sub eff} = 3.143{sup +0.064}{sub -0.066}, which favors ΔN{sub eff} > 0 at the 1.47σ CL, and m{sub ν,sterile}{sup eff} < 0.121 eV at the 2σ CL which is much tighter than the Planck results. This very tight restriction appears to indicate the massive sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration. (orig.)

  16. Forced sterilization of women as discrimination.

    Science.gov (United States)

    Patel, Priti

    2017-01-01

    There has been a long history of subjecting marginalized women to forced and coerced sterilization. In recent years, the practice has been documented in countries in North and South America, Europe, Asia, and Africa. It has targeted women who are ethnic and racial minorities, women with disabilities, women living with HIV, and poor women. A handful of courts have issued decisions on the recent forced sterilization of marginalized women finding that such actions violate the women's rights. However, they have all failed to address the women's claims of discrimination. The failure to acknowledge that forced sterilization is at its core a violation of the prohibition of discrimination undermines efforts to eradicate the practice. It further fails to recognize that coerced and forced sterilization fundamentally seeks to deny women deemed as "unworthy" the ability to procreate. Four key principles outlined in the human rights in patient care framework highlight the importance of a finding that the prohibition of discrimination was violated in cases of forced sterilization: the need to highlight the vulnerability of marginalized populations to discrimination in health care settings; the importance of the rights of medical providers; the role of the state in addressing systemic human rights violations in health care settings; and the application of human rights to patient care. Based on these principles, it is clear that finding a violation of the prohibition of discrimination in forced sterilization cases is critical in addressing the systemic nature of the practice, acknowledging the marginalization of specific groups and effectively ending forced sterilization through addressing the underlying purpose of the practice. If litigators, non-governmental organizations and judicial officers are mindful of these principles when dealing with cases of forced sterilization, it is likely that they will be better able to eradicate forced sterilization.

  17. Chemical sterilization of allograft dermal tissues.

    Science.gov (United States)

    Phipps, Abigail; Vaynshteyn, Edward; Kowalski, John B; Ngo, Manh-Dan; Merritt, Karen; Osborne, Joel; Chnari, Evangelia

    2017-12-01

    Common terminal sterilization methods are known to alter the natural structure and properties of soft tissues. One approach to providing safe grafts with preserved biological properties is the combination of a validated chemical sterilization process followed by an aseptic packaging process. This combination of processes is an accepted method for production of sterile healthcare products as described in ANSI/AAMI ST67:2011. This article describes the validation of the peracetic acid and ethanol-based (PAAE) chemical sterilization process for allograft dermal tissues at the Musculoskeletal Transplant Foundation (MTF, Edison, NJ). The sterilization capability of the PAAE solution used during routine production of aseptically processed dermal tissue forms was determined based on requirements of relevant ISO standards, ISO 14161:2009 and ISO 14937:2009. The resistance of spores of Bacillus subtilis, Clostridium sporogenes, Mycobacterium terrae, Pseudomonas aeruginosa, Enterococcus faecium, and Staphylococcus aureus to the chemical sterilization process employed by MTF was determined. Using a worst-case scenario testing strategy, the D value was calculated for the most resistant microorganism, Bacillus. The 12D time parameter determined the minimum time required to achieve a SAL of 10 -6 . Microbiological performance qualification demonstrated a complete kill of 10 6 spores at just a quarter of the full cycle time. The validation demonstrated that the PAAE sterilization process is robust, achieves sterilization of allograft dermal tissue to a SAL 10 -6 , and that in combination with aseptic processing secures the microbiological safety of allograft dermal tissue while avoiding structural and biochemical tissue damage previously observed with other sterilization methods such as ionizing irradiation.

  18. Microscope sterility during spine surgery.

    Science.gov (United States)

    Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J

    2012-04-01

    Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact

  19. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards......, the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  20. Spore-Forming Bacteria that Resist Sterilization

    Science.gov (United States)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  1. Radiation sterilization facility for melon fly

    International Nuclear Information System (INIS)

    Danno, A.

    1985-01-01

    The melon fly (Dacus cucurbitae Coquillett) has been observed in Amami Island since l975. Kagoshima Prefecture has had a melon fly eradication project underway since 1979. A mass-fearing facility and a radiation sterilization facility were constructed in Naze in March of l98l. In the early stages of the project, sterile insects were produced at the rate of 4 x l0/sup 6/ pupae/week. In the later stages, the activity of the project was enlarged by tenfold. The conditions for design of the radiation sterilization facility, which has been developed with a central control system for automated irradiation, are examined from an engineering standpoint

  2. Signatures of extra dimensional sterile neutrinos

    Directory of Open Access Journals (Sweden)

    Werner Rodejohann

    2014-10-01

    Full Text Available We study a large extra dimension model with active and sterile Dirac neutrinos. The sterile neutrino masses stem from compactification of an extra dimension with radius R and are chosen to have masses around eV or keV, in order to explain short-baseline anomalies or act as warm dark matter candidates. We study the effect of the sterile neutrino Kaluza–Klein tower in short-baseline oscillation experiments and in the beta spectrum as measurable by KATRIN-like experiments.

  3. Observations on female sterilization in Chile.

    Science.gov (United States)

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical

  4. Radiation sterilization of animal farm sewage

    International Nuclear Information System (INIS)

    Rosiak, J.; Perkowski, J.; Pekala, W.

    1984-01-01

    Influence of irradiation on organisms appearing in farm sewage has been discussed. Practical examples of employing the radiation to sterilization of municipal wastes and liquid sewage from the industrial swine farms have been presented. (author)

  5. How to make a sterile helper.

    Science.gov (United States)

    Downing, Philip A; Cornwallis, Charlie K; Griffin, Ashleigh S

    2017-01-01

    The sterile worker castes found in the colonies of social insects are often cited as archetypal examples of altruism in nature. The challenge is to explain why losing the ability to mate has evolved as a superior strategy for transmitting genes into future generations. We propose that two conditions are necessary for the evolution of sterility: completely overlapping generations and monogamy. A review of the literature indicates that when these two conditions are met we consistently observe the evolution of sterile helpers. We explain the theory and evidence behind these ideas, and discuss the importance of ecology in predicting whether sterility will evolve using examples from social birds, mammals, and insects. In doing so, we offer an explanation for the extraordinary lifespans of some cooperative species which hint at ways in which we can unlock the secrets of long life. © 2016 WILEY Periodicals, Inc.

  6. Encapsulation process sterilizes and preserves surgical instruments

    Science.gov (United States)

    Montgomery, L. C.; Morelli, F. A.

    1964-01-01

    Ethylene oxide is blended with an organic polymer to form a sterile material for encapsulating surgical instruments. The material does not bond to metal and can be easily removed when the instruments are needed.

  7. Determination of sterilizing dose of lincocine drug

    International Nuclear Information System (INIS)

    Adawi, M.A.; Shamma, M.; Al-Mousa, A.

    1998-01-01

    There are too many antibiotics that have been studied on their dry solid state to determine their safe sterilizing dose by decreasing their bio burden in order to reach the sterility assurance level (SAL) needed. The sterilizing radiating dose of lincocine was determined according to information about their bio burden and radiating sensitivity at the sterility assurance level 10-6. The study of bio burden has shown that the contamination was fungal (Pemicillium sp.) and by applying the same tests to the raw materials of lincocine it came out that the cause of contamination was bad storage and that the radiating dose required to decrease the bio burden was 5.5 kGy. (author)

  8. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study.

    Science.gov (United States)

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter; Sedrakyan, Art

    2015-10-13

    To compare the safety and efficacy of hysteroscopic sterilization with the "Essure" device with laparoscopic sterilization in a large, all-inclusive, state cohort. Population based cohort study. Outpatient interventional setting in New York State. Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. We identified 8048 patients undergoing hysteroscopic sterilization and 44,278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, Psterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures should be discussed with patients for informed decisions making. © Mao et al 2015.

  9. Cosmological and astrophysical implications of sterile neutrinos

    Science.gov (United States)

    Petraki, Kalliopi

    The discovery of neutrino masses suggests that the Standard Model should be supplemented with new gauge-singlet fermions, often called sterile neutrinos. The interplay among the new couplings introduced in the Standard Model can accommodate the neutrino oscillation data for a variety of choices: the new particles can be extremely heavy and practically unobservable, or they can be light, in which case they can solve several long-standing puzzles. It has been shown, for example, that sterile neutrinos in some range of masses can account for dark matter, their emission from a supernova can explain pulsar kicks, arid their decays can play an important role in the formation of the first stars. Though indirect, these clues indicate that sterile neutrinos can be the minimal solution to a variety of unsolved problems. This emphasizes the importance of investigating further the consequences of these new degrees of freedom for cosmology and astrophysics. In this dissertation, I explore the possible role of sterile neutrinos of different mass scales in some cosmological and astrophysical phenomena. A minimal extension of the Higgs sector of the Standard Model, with a gauge- singlet boson coupled to sterile neutrinos, can provide a consistent framework for the theory of neutrino masses, and can produce a relic population of keV sterile neutrinos via decays of the singlet Higgs. The latter can account for the dark matter of the universe. The mechanism operates around the electroweak scale, and has interesting consequences for the electroweak phase transition. Relic sterile neutrinos produced via decays at the electroweak scale constitute colder dark matter than those produced via other previously suggested mechanisms. The primordial thermal content of dark matter has important implications for the formation of cosmic structures, such as clusters and galaxies. The assessment of the relevant properties suggests that sterile neutrinos produced at the electroweak scale are a

  10. Ethylene Oxide Gas Sterilization of Medical Devices.

    Science.gov (United States)

    Shintani, Hideharu

    2017-01-01

     Ethylene oxide gas is an agent in the sterilization of medical devices due to its effectiveness and compatibility with most materials. The advantages and disadvantages, as well as its recommended uses, are explored in this review article. The variables and their relevance on process optimization are described, the types of processing cycles are detailed and emphasis is given to the design and validation of the sterilization process.

  11. Methods of sterilization and monitoring of sterilization across selected dental practices in karachi, pakistan

    International Nuclear Information System (INIS)

    Ahmed, H.

    2015-01-01

    To assess methods of sterilization in dental practices in Karachi and secondly to investigate methods of monitoring sterilization in dental practices in Karachi, Pakistan. Study Design: Cross-sectional, descriptive study. Place and Duration of Study: Dental colleges, hospitals and private clinics of Karachi, Pakistan, from January to March 2013. Methodology: A total of 251 questionnaires were obtained. Descriptive statistics were computed and differences between groups were assessed through chi-square test using Statistical Package for the Social Sciences (SPSS) version 16.0. P-value < 0.05 was taken as statistically significant. Results: Autoclave, used by 155 (61.8%) dentists was the most common method of sterilization followed by more than one method, 65 (25.9%); dry heat, 24 (9.6%); and cold sterilization, 7 (2.8%). Majority of dentists, 126 (50.1%), never monitored sterilization and those who did monitored mostly monthly. Statistically significant difference was found amongst the three groups of dentists monitoring sterilization (p=0.09) and methods of sterilization (p < 0.01). Conclusion: Statistically significant difference was found in infection control practices of specialists, postgraduate trainees and general dentists regarding method of monitoring sterilization with majority of dentists never monitoring sterilization. (author)

  12. Radiation sterilization of medical devices; Radiacyjna sterylizacja sprzetu medycznego

    Energy Technology Data Exchange (ETDEWEB)

    Kaluska, I.; Stuglik, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1996-12-31

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs.

  13. 21 CFR 880.2800 - Sterilization process indicator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by a...

  14. Voluntary sterilization in Serbia: Unmet need?

    Directory of Open Access Journals (Sweden)

    Rašević Mirjana M.

    2002-01-01

    Full Text Available Is voluntary sterilization as a birth control method accepted in Serbia? This is certainly a question that is being imposed for research, regardless of the fact that voluntary sterilization is neither accessible nor promoted. Most importantly because there is no understanding in the social nor political sphere for legalization of voluntary sterilization as a form of birth control, apart from the clear necessity for this, first, step. They are: the recognition that voluntary sterilization is an efficient and safe birth control method, respectability of basic human as well as sexual and reproductive rights, spreading of sterilization as a form of birth control among population of both developed and developing countries and an epidemic diffusion of repeated induced abortions in Serbia. Thus individual recognition of the advantages of relying on voluntary sterilization, in a non-encouraging atmosphere, certainly represents one more argument to enable couples to prevent conception by sterilization. Since it was impossible to carry out a representative research among the population of men and women who are at risk for conception, an attempt was made to obtain a reply to the set question among women who decided to induce abortion. It was done out of at least two reasons. The first being that women with induced abortion in their reproductive history were the target group for voluntary sterilization. The second reason was based on the assumption that bringing a decision on induced abortion is preceded by the reconsideration of an earlier adopted strategy regarding children, giving birth and contraception and thus its rational component is revealed more and therefore more easily measurable. The research was carried out in the University Clinic of Obstetrics and Gynecology 'Narodni front' in Belgrade from January 21st o March 1st 2002, and included 296 women. By comparing the social and demographic characteristics of the female respondents, as well as

  15. Infezione sperimentale di capre con un ceppo atipico di Mycoplasma mycoides subsp. capri isolato in Giordania: confronto tra differenti metodi diagnostici

    Directory of Open Access Journals (Sweden)

    Massimo Scacchia

    2010-06-01

    Full Text Available Sono state infettate sperimentalmente 10 capre con un micoplasma identificato con metodi biomolecolari come Mycoplasma mycoides subsp. capri, ceppo Irbid, isolato da capre in un focolaio di agalassia contagiosa nel nord della Giordania e definito atipico per la sua peculiarità sierologica. Due gruppi di animali infettati rispettivamente per via endotracheale e aerosol sono stati posti in contatto con un terzo gruppo di capre. A sei settimane dall’infezione alcuni animali, sia infettati sia posti in contatto, hanno manifestato febbre, scolo nasale, seguiti da grave sintomatologia respiratoria e poliartrite. Dagli animali deceduti o sacrificati, perché giunti al termine della sperimentazione, sono stati effettuati prelievi di organi. Dopo una descrizione dei quadri clinici ed anatomo-istopatologici, sono stati messi a confronto gli esiti degli isolamenti microbiologici e delle prove immunoisto-chimiche effettuate sugli organi prelevati.

  16. Probability of pregnancy after sterilization: a comparison of hysteroscopic versus laparoscopic sterilization.

    Science.gov (United States)

    Gariepy, Aileen M; Creinin, Mitchell D; Smith, Kenneth J; Xu, Xiao

    2014-08-01

    To compare the expected probability of pregnancy after hysteroscopic versus laparoscopic sterilization based on available data using decision analysis. We developed an evidence-based Markov model to estimate the probability of pregnancy over 10 years after three different female sterilization procedures: hysteroscopic, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation. Parameter estimates for procedure success, probability of completing follow-up testing and risk of pregnancy after different sterilization procedures were obtained from published sources. In the base case analysis at all points in time after the sterilization procedure, the initial and cumulative risk of pregnancy after sterilization is higher in women opting for hysteroscopic than either laparoscopic band or bipolar sterilization. The expected pregnancy rates per 1000 women at 1 year are 57, 7 and 3 for hysteroscopic sterilization, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation, respectively. At 10 years, the cumulative pregnancy rates per 1000 women are 96, 24 and 30, respectively. Sensitivity analyses suggest that the three procedures would have an equivalent pregnancy risk of approximately 80 per 1000 women at 10 years if the probability of successful laparoscopic (band or bipolar) sterilization drops below 90% and successful coil placement on first hysteroscopic attempt increases to 98% or if the probability of undergoing a hysterosalpingogram increases to 100%. Based on available data, the expected population risk of pregnancy is higher after hysteroscopic than laparoscopic sterilization. Consistent with existing contraceptive classification, future characterization of hysteroscopic sterilization should distinguish "perfect" and "typical" use failure rates. Pregnancy probability at 1 year and over 10 years is expected to be higher in women having hysteroscopic as compared to laparoscopic sterilization. Copyright © 2014

  17. Radiation sterilization of aseptically manufactured products.

    Science.gov (United States)

    Fairand, Barry P; Fidopiastis, Niki

    2010-01-01

    This paper discusses an approach for establishing a sterilization dose for an aseptically processed product after the product is in its final packaged state, in other words, terminal sterilization. It applies to aseptic processes where the fill/finish operation is conducted in a closed system using isolator or restricted access barrier technology, that is, no human intervention. The example that is given in this paper uses gamma radiation as the sterilizing agent. Other forms of radiation such as high-energy electrons or X-rays also could serve as the sterilizing agent. The proposed approach involves irradiation of the aseptically processed product at very low doses of radiation, which is possible due to the extremely low levels of bioburden that may be present on the product following a fill/finish operation. Rather than sacrificing a large number of product units that may be required to obtain a statistically significant sampling of the product for bioburden analysis and other test purposes, the test unit is a surrogate consisting of actual pharmaceutical product that was inoculated with a highly radiation-resistant micro-organism. Selection of the microorganism was based on analysis of a library of environmental monitoring data taken from the aseptic area. Because of microbial diversity between different aseptic processing facilities, selection of the test microorganism would depend on the aseptic area under study. The approach that is discussed in this paper addresses selection and preparation of the surrogate, test of sterility of the surrogate following irradiation, determination of the radiation resistance of the test microorganism, and application of the approach to calculate a sterilization dose that is less than 10 kGy. At this low dose, it may be possible to terminally sterilize radiation-sensitive pharmaceutical products, for example, those in liquid form. Additional studies are warranted to determine the general applicability of the proposed approach.

  18. Sterilization Performance and Material Compatibility of Sterilizer for Dental Instruments using RF Oxygen Plasma

    Science.gov (United States)

    Sakai, Yasuhiro; Liu, Zhen; Hayashi, Nobuya; Goto, Masaaki

    2015-09-01

    The sterilization performance and material compatibility of low-pressure RF plasma sterilization method for dental instruments were investigated. RF electrode used in this experiment has been optimized for sterilization of dental instruments. The vial-type biological indicator (BI) simulating tiny space of dental instrument was used for evaluation of the sterilization performance. The pressure in the stainless chamber was fixed at 60 Pa. Sterilization of BI was achieved in shortest time 40 min at 80 W, and the sterilization effect was confirmed using three BIs. Light emission spectra of oxygen plasma indicated that production of atomic oxygen and excited oxygen molecule are maximum at pressure of 20 Pa and 200 Pa, respectively. Sterilization results of BIs indicated that successful rate increases with the oxygen pressure towards 200 Pa. Therefore, the excited oxygen molecule is deduced to be a major factor of the sterilization of BI. Surface morphology of dental instruments such as diamond bar was evaluated using scanning electron microscope (SEM). The deterioration of fine crystals of diamond bar has not observed after the plasma irradiation for 120 min with RF input power was 60W and pressure was 200 Pa.

  19. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice

    NARCIS (Netherlands)

    El-Namaky, R.; Oort, van P.A.J.

    2017-01-01

    Background: There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two

  20. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America.

    Science.gov (United States)

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35-13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker training on HIV and reproductive rights

  1. Gamma radiation sterilized amnion: use in ophthalmology

    International Nuclear Information System (INIS)

    Martinez P, M. E.; Leon T, Y.; Vazquez M, L.

    2010-10-01

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with 60 Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  2. Gamma radiation sterilized amnion: use in ophthalmology

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Leon T, Y. [Hospital General Regional 220, IMSS, Paseo Tollocan No. 620, Col. Vertice, Toluca 50150, Estado de Mexico (Mexico); Vazquez M, L., E-mail: esther.martinez@inin.gob.m [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06720 Mexico D. F. (Mexico)

    2010-10-15

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with {sup 60}Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  3. Revisiting cosmological bounds on sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, Aaron C. [Institute for Particle Physics Phenomenology (IPPP), Department of Physics, Durham University, Durham DH1 3LE (United Kingdom); Martínez, Enrique Fernández [Departamento and Instituto de Física Teórica (IFT), UAM/CSIC, Universidad Autonoma de Madrid, C/ Nicolás Cabrera 13-15, E-28049 Cantoblanco, Madrid (Spain); Hernández, Pilar; Mena, Olga [Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Lattanzi, Massimiliano, E-mail: aaron.vincent@durham.ac.uk, E-mail: enrique.fernandez-martinez@uam.es, E-mail: m.pilar.hernandez@uv.es, E-mail: omena@ific.uv.es, E-mail: lattanzi@fe.infn.it [Dipartimento di Fisica e Science della Terra, Università di Ferrara and INFN, sezione di Ferrara, Polo Scientifico e Tecnologico, Edificio C Via Saragat, 1, I-44122 Ferrara (Italy)

    2015-04-01

    We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expected in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.

  4. Sterilization and disinfection: the prevailing indifference

    International Nuclear Information System (INIS)

    Mirza, I.

    2007-01-01

    To evaluate the knowledge and attitude of health care professionals towards the process of sterilization and disinfection, and to check the adequacy of the reading material accessible to them. The study comprised of three components. In the first part, sections devoted to this subject in the popular books read by the students of operation theatre assistant course and students of diploma in general nursing were examined for adequacy and authenticity of information. In the second part, standard operating procedures were examined regarding sterilization of textile, rubber tubes of suction units and diathermy hand pieces of 20 operation theatres of three teaching hospital attached to undergraduate medical college of Punjab. In the third part of the study, working knowledge of 64 practicing operation theatre assistants and 57 practicing nurses was assessed through a questionnaire. It was found that popular books either did not contain the required information or the information provided was misleading or incorrect. Standard operating procedures for sterilization of selected items of all the operation theatres studied fell much below the standard of practice desired in the light of current knowledge and contemporary practices. Finally the working knowledge of the professionals studied was much below the bare minimum expected by the profession. There is a dire need for upgrading the knowledge and attitude of health care professionals regarding sterilization, besides improving the operation theatres sterilization procedures. (author)

  5. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Vijaya Krishnan

    2004-12-01

    Full Text Available Prior to early 1970s, traditional methods were the principal means of controlling the number and spacing of births. Today, an estimated 57 per cent of the world’s married women use contraceptives and half use modern methods such as medical sterilizations. Recent statistics suggest that Canada has the highest sterilization rate in the Western world. This paper presents findings of research examining sterilization trends in Canada with respect to changing patterns in the use of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995 General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligation and an increase in the use of hysterectomy over the period 1984-1995. Less educated women are more likely to be in the forefront of modern methods of contraception.

  6. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards...... and documented uncertainty limits of the dose measurements can be used to specify process control limits. This is also useful, for example, when dose setting experiments are carried out according to the methods described in ISO 11137, where product samples shall be irradiated within narrow limits......., the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  7. Radiation Fusion Technology for Sewage Sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M. J.; Kim, T. H.; Ryu, S. H.; Jung, I. H.; Lee, O. M.; Kim, T. H. [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2011-05-15

    Environmental regulation for effluent of sewage and wastewater treatment plant is going to be reinforced in terms of ecology toxicity and number of E.coli from 2011. Besides, it has been known that UV technology is not enough to be a sterilization tool due to regrowth of E.coli even after treatment with UV. Therefore it needs a novel technology for both restriction of E.coli regrowth and treatment of toxic materials in order to meet the environmental regulation being enforced. Electron beam has unique capabilities on destruction of chemicals and sterilization of microbial. In this study, field study on destruction of antibiotics and endocrine disruptors, reduction ecological toxicity and E.Coli regrowth was carried out using by mobile electron beam accelerator. Experimental results showed that irradiation on effluent could effectively reduce not only ecology toxicity but regrowth of E.coli by destruction of chemicals and complete sterilization

  8. Induced mutant for male sterility in niger

    International Nuclear Information System (INIS)

    Sujatha, M.

    2001-01-01

    Full text: Niger (Guizotia abyssinica Cass.), an important oilseed crop of the family Compositae is highly cross-pollinated due to the twin mechanisms of protandry and incompatibility. Studies revealed the functional nature of protandry and the breakdown of incompatibility with alteration in temperature. It has very small flowers (disc florets) arranged in a capitulum that open on 3-4 consecutive days which pose problems in emasculation for cross-breeding. To induce mutations, seeds of variety 'IGP-76' were irradiated with γ-rays 200 to 1000 Gy. All seeds of M 1 plants were sown separately in individual plant-to progeny rows. The results of screening of M 2 segregating material indicated that γ-ray treatment was effective in induction of male sterility. Frequency of visible mutations were higher in sibbed progeny as compared to open pollinated population and male sterile plants were observed only in sibbed population (1000 Gy). Male sterile plants could easily be identified at the flowering stage by their altered floral morphology (disc florets transformed into ligulate ray florets) and complete absence or presence of a rudimentary anther column. Seeds were collected following sib-mating with the fertile counterparts. Progeny segregated in a ration of 3 normal : 1 male sterile. Further work on the mechanism of sterility, maintenance and linkage relationships with associated characters is under progress. This is the first report of induction of male sterility in niger through the use of physical mutagens. The availability of this mutant will be of great value for exploitation of heterosis on commercial basis. (author)

  9. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Raquel Galante

    Full Text Available In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation, a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP hydrogel nanoparticles (CS-HNP, with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol. Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  10. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Science.gov (United States)

    Galante, Raquel; Rediguieri, Carolina F; Kikuchi, Irene Satiko; Vasquez, Pablo A S; Colaço, Rogério; Serro, Ana Paula; Pinto, Terezinha J A

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  11. SOX. Search for sterile neutrinos with Borexino

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Mikko [Institut fuer Experimentalphysik, Universitaet Hamburg (Germany); Collaboration: BOREXINO-Collaboration

    2016-07-01

    Several observed anomalies in the neutrino sector could be explained by a 4th (sterile) neutrino with a squared mass difference in the order of 1 eV{sup 2} to the other three standard neutrinos. This hypothesis can be tested with an artificial kCi antineutrino (Ce-144/Pr-144) source deployed near or inside a large low background detector like Borexino. The SOX project (short baseline neutrino oscillation with Borexino) aims for the detection of sterile neutrinos and offers the almost unique possibility to observe the characteristic antineutrino oscillation pattern within the detector. The talk summarizes this concept and shows the sensitivities for the possible phases of the experiment.

  12. Solar neutrino detectors as sterile neutrino hunters

    Science.gov (United States)

    Pallavicini, Marco; Borexino-SOX Collaboration; Agostini, M.; Altenmüller, K.; Appel, S.; Atroshchenko, V.; Bellini, G.; Benziger, J.; Berton, N.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Carlini, M.; Cavalcante, P.; Chepurnov, A.; Choi, K.; Cloué, O.; Cribier, M.; D'Angelo, D.; Davini, S.; Derbin, A.; Di Noto, L.; Drachnev, I.; Durero, M.; Etenko, A.; Farinon, S.; Fischer, V.; Fomenko, K.; Franco, D.; Gabriele, F.; Gaffiot, J.; Galbiati, C.; Gschwender, M.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Houdy, Th.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jany, A.; Jedrzejczak, K.; Jeschke, D.; Jonquères, N.; Kobychev, V.; Korablev, D.; Korga, G.; Kornoukhov, V.; Kryn, D.; Lachenmaier, T.; Lasserre, T.; Laubenstein, M.; Lehnert, B.; Link, J.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Marcocci, S.; Maricic, J.; Mention, G.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Mosteiro, P.; Muratova, V.; Musenich, R.; Neumair, B.; Oberauer, L.; Ortica, F.; Papp, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Reinert, Y.; Romani, A.; Roncin, R.; Rossi, N.; Schönert, S.; Scola, L.; Semenov, D.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Veyssière, C.; Vishneva, A.; Vivier, M.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.

    2017-09-01

    The large size and the very low radioactive background of solar neutrino detectors such as Borexino at the Gran Sasso Laboratory in Italy offer a unique opportunity to probe the existence of neutrino oscillations into new sterile components by means of carefully designed and well calibrated anti-neutrino and neutrino artificial sources. In this paper we briefly summarise the key elements of the SOX experiment, a program for the search of sterile neutrinos (and other short distance effects) by means of a 144Ce-144Pr anti-neutrino source and, possibly in the medium term future, with a 51Cr neutrino source.

  13. Dynamic sterilization of titanium implants with ultraviolet light

    International Nuclear Information System (INIS)

    Singh, S.; Schaaf, N.G.

    1989-01-01

    All implantable devices must be sterile. However, autoclaves produce poor surface properties that jeopardize the integration process. The application of a modified ultraviolet light source has proven to enhance bioreactivity by controlling surface properties, but it lacks validation of its sterilization capabilities. Forty-eight titanium implants were contaminated with spores of the biological indicator Bacillus stearothermophilus and subjected to dynamic sterilization by ultraviolet light. Forty-seven of the implants were successfully sterilized, as indicated by not producing turbidity in a suitable growth medium. This sterilization technique only requires a 20-second exposure to achieve sterility

  14. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    preferable since they have an automatic timer for the working cycle and because they are equipped with handy containers for instruments. The pressure cooker ... Therefore dry heat sterilizers should have a time lock on the door to prevent misuse. The shelves inside must be perforated and instruments should not be tightly ...

  15. Whey powder sterilization by ionizing irradiation

    International Nuclear Information System (INIS)

    Todorovic, M.; Salatic, Z.; Markov, S.

    1988-01-01

    Whey powder was sterilized by gamma waves application. As a source of irridiation isotope 60Co was used in Institute of Nuclear sciences B oris Kidrich , Vincha-Belgrade (Yugoslavia). The applied doses were: a, b, c, d, and e Kgy. The dose d was radappertization. After whey powder irradiation no adverse changes of organoleptic properties were noticed

  16. sensitive genic male sterile (PGMS) rice

    African Journals Online (AJOL)

    user

    2011-04-18

    Apr 18, 2011 ... phosphate buffered solution; TEM, transmission electron microscope; CMS, cytoplasmic male sterile; FPR, first photo reaction; SPR, second photo reaction. production of cytotoxins which instigate apoptosis. For example in Caenorhabditis elegans, the ced genes code for cystein proteases Ced-3 and Ced-4 ...

  17. Light sterile neutrinos: Status and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Giunti, Carlo

    2016-07-15

    The indications in favor of the existence of light sterile neutrinos at the eV scale found in short-baseline neutrino oscillation experiments is reviewed. The future perspectives of short-baseline neutrino oscillation experiments and the connections with β-decay measurements of the neutrino masses and with neutrinoless double-β decay experiments are discussed.

  18. Detecting sterile neutrinos with KATRIN like experiments

    DEFF Research Database (Denmark)

    Riis, Anna Sejersen; Hannestad, Steen

    2011-01-01

    A sterile neutrino with mass in the eV range, mixing with bar nue, is allowed and possibly even preferred by cosmology and oscillation experiments. If such eV-mass neutrinos exist they provide a much better target for direct detection in beta decay experiments than the active neutrinos which...

  19. 21 CFR 610.12 - Sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Sterility. 610.12 Section 610.12 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS GENERAL... of the organisms and ensure freedom from contamination and deterioration. If the test organisms are...

  20. Gamma radiation sterilization of Bactrocera invadens (Diptera ...

    African Journals Online (AJOL)

    The African invader fly, Bactrocera invadens, an invasive pest in Africa since 2003, causes damage and poses a threat to the mango and horticultural industry. Its control is therefore needed. Sterilization of males using gamma radiation doses (25, 50 and 75 Gy) as a means of population control was investigated. Irradiation ...

  1. STERILIZATION AND DISINFECTION IN A PRIVATE CLINIC

    African Journals Online (AJOL)

    Oral examination is done with a mirror and probe. The mirror is then washed under the tap water and disinfected in 'V3 sterilizing' fluid concentrate. The probe is placed in a tray with ... Protective glasses are worn additionally to the gloves and facemask, when cavity preparation. is being performed. The handpiece is wiped.

  2. Sterilization of heparinized cuprophan hemodialysis membranes

    NARCIS (Netherlands)

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated.

  3. Sterilization: A Conference and a Report.

    Science.gov (United States)

    Dillingham, Brint

    1978-01-01

    This article continues a series on Native American sterilization, based on a conference of the National Council of Churches' Interreligious Foundation for Community Organization (IFCO). Also included are an article and a report by the American Civil Liberties Union. (Author/RTS)

  4. Steam sterilization of air turbine dental handpieces.

    Science.gov (United States)

    Edwardsson, S; Svensäter, G; Birkhed, D

    1983-12-01

    The efficacy of autoclaving high-speed dental handpieces was tested in two types of downward displacement steam sterilizers (instrument autoclaves), commonly used in the dentist's office. Eight series of experiments were performed with various sterilization schedules. Lubrication oils with or without antimicrobial agent were used in four of the series. Each handpiece was inoculated with 1 ml of a suspension containing equal amounts of saliva and spores of Bacillus stearothermophilus (approx. 10(6) spores/ml). Neither sterilization at 120-124 degrees C for 20 min nor at 134-136 degrees C for 10 min resulted in complete inactivation of the spores in series in which the instruments were tested without oil or with oil containing no antimicrobial agent. However, when the handpieces were lubricated with oil containing isopropanol and formaldehyde and the schedule 134-136 degrees C/10 min was used, no growth was observed. The results indicate that instrument autoclaves with built-in programs of 120-124 degrees C/20 min and 134-136 degrees C/10 min could have insufficient capacity to sterilize lubricated or unlubricated dental handpieces. The use of oils containing an antimicrobial agent can overcome this problem.

  5. Utilization of male sterility in forage crops

    International Nuclear Information System (INIS)

    Suginobu, Ken-ichi

    1982-01-01

    The genetic nature of male sterility in forage crops was reviewed. Many workers have suggested that hybrids in forage crops are quite promising. First, the selection of the most desirable parental genotype from a large original population is improtant in heterosis breeding programs. After the more promising inbreds or clones have been selected on the basis of good general combining ability, it is necessary to identify the particular single, three-way or double cross that will produce the highest yields. A high seed yield potential is also important in a new variety so that the seeds can be sold at lower prices than other varieties. A tentative scheme for hybrid seed production by using inbred lines of male sterile or normal parents is proposed. At a breeding station, the seeds for male sterile F 1 (AB), maintainer S 1 (C-S 1 ) and either maintainer or restorer S 1 s(D-S 1 , E-S 1 ) are produced from the parental clones. At a seed increase agency, the seeds for male sterile F 1 (ABC) and either maintainer or restorer S 2 (D-S 2 ) are produced. In the case that D-S 2 seed production is difficult, maintainer or restorer F 1 (DE) should be produced from D-S 1 x E-S 1 . These seeds are used for commercial seed production. Seeds of hybrid F 1 (ABCD) or hybrid F 1 (ABCDE) are for practical use. (Kaihara, S.)

  6. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    rust carbon steel instruments and after the work cycle is ended instruments are dry and immediately available for use. Besides the disadvantage of chemical odour in a poorly ventilated room its major drawback is its dependence on a continuous supply of the chemical agent. Dry heat sterilization. This method has the lowest ...

  7. Present studies on the radio-sterilized drugs

    International Nuclear Information System (INIS)

    Marciniec, B.; Dettlaff, K.

    2007-01-01

    Lecture presents present status of radiosterilization of drugs and medical materials as compared to other sterilization methods. Literature review is shown on degradation of different kinds of drugs sterilized upon action of the sterilising doses of radiation

  8. Present status in radiation sterilization of medical products

    International Nuclear Information System (INIS)

    Sato, Kenji

    1982-01-01

    The attempt to sterilize the disposable medical supplies of plastics and protein by radiation started as early as 1958. In the world, more than 80 such installations have been set up and operated at present. In recent years, the guarantee for sterilization has been emphasized; the trend is now for the worldwise standardization of the process control and the method of determining sterilization radiation dose. In Japan, there exist three installations equipped with 60 Co gamma -ray irradiation apparatus. The medical supplies over 20 items including artificial kidney dialyzer, injection needles and surgical stitches are radiation sterilized and practically used presently. The following matters are described: radiation sterilization facilities, sterilization process control, sterilization conditions (radiation dose), the radiation resistance of microorganisms, radiation-sterilized medical supplies. (Mori, K.)

  9. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    International Nuclear Information System (INIS)

    Parker, A.; Mehta, K.

    2007-01-01

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discuss optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [es

  10. Sterility maintenance assessment of moist/wet material after steam sterilization and 30-day storage.

    Science.gov (United States)

    Moriya, Giovana Abrahão de Araújo; Graziano, Kazuko Uchikawa

    2010-01-01

    Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupted, yielding moist/wet materials and the other half (the negative control group) underwent the complete cycle. The external parts of each surgical box were deliberately contaminated with Serratia marcescens and subsequently stored for 30 days. After this period, the boxes' contents were submitted to sterility tests and no growth was observed. The presence of moisture inside the surgical boxes did not interfere with maintaining their sterility.

  11. X-ray sterilization of insects and microorganisms for cultural heritage applications

    Science.gov (United States)

    Borgognoni, F.; Vadrucci, M.; Bazzano, G.; Ferrari, P.; Massa, S.; Moretti, R.; Calvitti, M.; Ronsivalle, C.; Moriani, A.; Picardi, L.

    2017-09-01

    The APAM (Development of Particle Accelerators and Medical Applications) Laboratory of the ENEA Frascati Research Center is engaged in the preservation of cultural heritage as part of the COBRA (Sviluppo e diffusione di metodi, tecnologie e strumenti avanzati per la COnservazione dei Beni culturali, basati sull'applicazione di Radiazioni e di tecnologie Abilitanti) project addressed to the transfer of innovative technologies and methodologies from research to small and medium enterprises involved in the restorative measures. This work aims to demonstrate the effectiveness of ionizing radiation on the disinfection of biodegraded art objects. The conventional methods for the disinfestation of works of art, using chemicals toxic to humans and environment, might cause some damage to the treated material even on micrometric scale (i. e. either cellulose degradation). Ionizing radiations interact with the infesting biological material causing an irreversible DNA degradation. For this reason, they are certainly suitable for removal treatments of both macro organisms and bacterial colonies. A 4.8 MeV electron linear accelerator, normally dedicated to the characterization of dose detectors and radiographies, has been employed to produce Bremsstrahlung X-rays through a lead converter. The spectral fluence of the radiation source has been calculated using the Monte Carlo MCNPX code. The dosimetric characterization of the radiation field has been made using radiochromic films sensitive in the dose range of our interest (from 50 to 500 Gy) calibrated with a Markus ionization chamber. The irradiation of the artifact prototypes are made within a lead shielded room at a variable distance from the X-rays source. Samples subjected to irradiation consist of a soil bacterium, Agrobacterium rhizogenes, and an insect, Stegobium paniceum, that are found as wall paintings invasive coloniser and as a pest of books, wood works and paintings, respectively. Tests of irradiation have been

  12. Laparoscopic tubal sterilization reversal and fertility outcomes

    Directory of Open Access Journals (Sweden)

    K Jayakrishnan

    2011-01-01

    Full Text Available Purpose: The purpose of the study was two-fold. Firstly it was to assess the suitability for tubal recanalization and factors predicting successful laparoscopic recanalization. Secondly, it was to analyze the fertility outcomes and factors affecting the pregnancy rate following laparoscopic tubal recanalization. Materials and Methods: A retrospective chart review of prospectively followed-up 29 women at a tertiary care center seeking tubal sterilization reversal between May 2005 and February 2010 were included. Results: In 14 (48.3% women unilateral tubes were suitable and in only 3 women (10.3% bilateral tubes were suitable. All cases with laparoscopic tubal sterilization were suitable, whereas all cases with fimbriectomy were unsuitable for recanalization. In 6 (20.7% cases salphingostomy was performed as an alternative procedure to tubal reanastomosis. The overall pregnancy rate was 58.8%. In cases with sterilization by Pomeroy′s method, 4 out of 10 (40% conceived, whereas for laparoscopic tubal ligation cases 6 out of 7 (85.7% conceived (P=0.32. None of the patients with final tubal length <5 cm conceived (P=0.03. Comparing the age at recanalization, in women ≤30 years, 71.4% conceived, as compared with 50% when age of women was more than 30 years (P=0.37. Conclusions: The important factors determining the success of recanalization are technique of sterilization and the remaining length of the tube after recanalization. The gynecologist must use an effective technique of sterilization to minimize the failure rates, but at the same time, which causes minimal trauma, and aim at preserving the length of the tube so that reversal is more likely to be successful, should the patient′s circumstances change.

  13. Device and Container for Reheating and Sterilization

    Science.gov (United States)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  14. Status of radiation sterilization of healthcare products in China

    International Nuclear Information System (INIS)

    Zhu Nankang; Wang Chunlei; Teng Weifang

    2004-01-01

    This paper describes the status of 60 Co radiation facilities both in service and under construction in China and examines the future market for radiation sterilization of healthcare products. Policies for developing the industry of radiation sterilization are also put forward; these include implementation of appropriate quality systems, scale-up and merging of existing radiation facilities, development of electron beam radiation for sterilization purposes and increasing awareness of the technology of radiation sterilization

  15. Sterility Maintenance Assessment of Moist/Wet Material After Steam Sterilization and 30-day Storage

    OpenAIRE

    Moriya,Giovana Abrahão de Araújo; Graziano,Kazuko Uchikawa

    2010-01-01

    Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupt...

  16. [Study of the reproducibility of the sterilization process and proposal of an sterilizer requalification protocol].

    Science.gov (United States)

    Gibory, V; Robelet, A; Riou, J; Lebelle Dehaut, A-V

    2018-03-01

    Unlike EN 554, and since the publication of ISO 17665-1 standard, the user of autoclaves may use methods other than those indicated in the guidelines. Outsourcing the requalification of sterilizers by an external service provider and after observing from the previous requalification reports that the thermometric data seemed reproducible, we decided to propose and validate a validation method for the reproducibility of the sterilization process. This is to exempt from the study of the repeatability of the EN 554 standard in future requalifications. Reproducibility was studied with the sensors of the sterilization service and from the production cycles. This study was carried out in three parts. First, we checked whether our sensors were reliable. Then we evaluated the sterilization process fidelity of each sterilizer. Finally, we compared our measurements performed by the service sensors with the measurements performed by the service provider during the requalifications of the previous years. This work leads us to describe a new protocol of requalification of our sterilizers. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  17. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to...

  18. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  19. 21 CFR 522.82 - Aminopropazine fumarate sterile solution injection.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Aminopropazine fumarate sterile solution injection... ANIMAL DRUGS § 522.82 Aminopropazine fumarate sterile solution injection. (a) Specifications. Each milliliter of aminopropazine fumarate sterile aqueous solution, veterinary, contains aminopropazine fumarate...

  20. 21 CFR 872.6710 - Boiling water sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  1. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by the...

  2. 42 CFR 441.255 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 441.255 Section 441.255 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a...

  3. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period (minutes) Directions T303-b-1 10 lbs 20 Use 28″ vacuum. Steam sterilization is not practical for treatment...

  4. Monitoring of steam sterilization processes in the dental office

    NARCIS (Netherlands)

    van Doornmalen, J.P.C.M.; Rietmeijer, A.G.M.; Feilzer, A.J.; Kopinga, K.

    2013-01-01

    In dental offices steam sterilization is used to prevent infection of staff and patient. The necessity of sterilization is obvious. To ensure effective sterilization processes each load has to be monitored. Based on literature and standards a state of the art concept of every load monitoring is

  5. The Coercive Sterilization of Aboriginal Women in Canada

    Science.gov (United States)

    Stote, Karen

    2012-01-01

    This paper considers the coercive sterilization of Aboriginal women in legislated and non-legislated form in Canada. I provide an historical and materialist critique of coercive sterilization. I argue for coercive sterilization to be understood as one of many policies employed to undermine Aboriginal women, to separate Aboriginal peoples from…

  6. Użyteczność metody k-średnich w klasyfikacji przedsiębiorstw według ich kondycji finansowej

    Directory of Open Access Journals (Sweden)

    Joanna Dyczkowska

    2010-11-01

    Full Text Available Otoczenie i warunki rynkowe, w jakich działają przedsiębiorstwa budowlane, mają klu-czowy wpływ na podejmowane przez te podmioty decyzje, znajdujące odzwierciedlenie w ich sprawozdaniach finansowych. Ocena kondycji finansowej przedsiębiorstwa budowlanego z za-miarem zdiagnozowania kryzysu nie powinna odbywać się w oderwaniu od sytuacji rynkowej. W artykule dokonano klasyfikacji przedsiębiorstw budowlanych notowanych na Warszawskiej Giełdzie Papierów Wartościowych według ich pozycji konkurencyjnych z wykorzystaniem metody k-średnich. Algorytm ten umożliwiła podział badanych podmiotów na pięć klas obiektów: o najlepszej, dobrej, przeciętnej, słabej i najsłabszej kondycji finansowej. Przeprowadzone postępowanie przyczyniło się również do ustalenia wielkości wskaźników charakteryzujących każdą grupę przedsiębiorstw. Tego typu analiza jest przydatnym narzędziem przede wszystkim dla inwestorów, gdyż infor-muje o tym, jak badane przedsiębiorstwo prezentuje się na tle podmiotów o podobnym profilu działalności.

  7. The dynamics of gynodioecy in Plantago lanceolata L. .1. Frequencies of male-steriles and their cytoplasmic male sterility types

    NARCIS (Netherlands)

    De Haan, A.A.; Luyten, R.M.J.M.; Bakx-Schotman, Tanja; Van Damme, J.M.M.

    1997-01-01

    The maintenance of a gynodioecious breeding system (hermaphrodites and male-steriles) was studied in Plantago lanceolata. Cytoplasmic-nuclear inheritance is important in the maintenance of male-steriles. The male-sterile trait is cytoplasmically based (CMS), and male fertility can be restored by

  8. Coelioscopic and Endoscope-Assisted Sterilization of Chelonians.

    Science.gov (United States)

    Proença, Laila M; Divers, Stephen J

    2015-09-01

    Elective sterilization is a safe and well-established surgical procedure performed in dogs and cats worldwide. Conversely, chelonian sterilization has been mostly performed therapeutically, because of the intricate anatomy and difficult access to the reproductive organs, and consequently, reproductive problems and diseases remain common. With the advance of veterinary endoscopy, novel techniques of soft tissue prefemoral coelioscopic and endoscope-assisted sterilization have been published, and preventative chelonian sterilization is now a reality. Nevertheless, extrapolations between species should be carefully considered, and further studies are warranted. This article summarizes and describes the current coelioscopic and coelioscope-assisted sterilization techniques for chelonia. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Sterilization of solutions for parenterals products. Problem analysis

    Directory of Open Access Journals (Sweden)

    Yanelys Montes-González

    2017-09-01

    Full Text Available The solutions for the formulation of parenteral products must be sterile before the aseptic formulation process. For this reason, different methods of sterilization referred in the literature are analyzed. Thermodynamic criteria that rule the sterilization are presented. Furthermore, previous experiences in the sterilization of solutions for the formulation of parental products in an autoclave are analyzed, that take large time of processing and only low volumes of solution can be handled. Using jacketed stirred tanks for the sterilization may solve the problem and, therefore, criteria for the design of the later that allow to process high volumes of solution for the formulation of parenteral products are shown.

  10. Radiation sterilization of medical products- current trends and future prospects

    International Nuclear Information System (INIS)

    Sharma, G.

    1997-01-01

    In medical practice use of sterile pharmaceuticals and single use disposable medical devices is steadily increasing. Sterile pharmaceuticals like injections and ophthalmic ointments are required for therapy. Medical devices are employed for diagnostic, drug administration or corrective purposes, and as implants for temporary, short term or long term residence in the human system. All these products are made available in sterile form by treating them to a suitable process of sterilization i.e. dry/wet heat, ethylene oxide (EtO) gas or ionizing radiation. In this paper current trends and future prospects of radiation sterilization of medical products are given in detail. 9 refs., 7 tabs

  11. Energy analysis in sterilization process of food

    International Nuclear Information System (INIS)

    Lee, Dong Sun; Pyun, Yu Ryang

    1986-01-01

    A procedure was developed for predicting energy consumption of batch type thermal processing of food. From mass and energy balance equations various energy usages or losses were estimated for steam sterilization of model food system in No.301-7 can (Φ74.1 x 113.0mm) at three different temperatures. Selected models were 5 % bentonite solution for conductive food and tap water for convective food. Total steam or energy consumption was higher at 110 deg C than at two other higher temperatures (121 deg C and 130 deg C). High energy consumption at low sterilization temperature was mainly due to high bleeding steam energy and convective and radiative heat losses. Thermal energy efficiency was also disscussed. (Author)

  12. Sterilization of activated sludges by gamma radiations

    International Nuclear Information System (INIS)

    Lacroix, J.P.; Boland, M.

    1978-01-01

    The purification process of a wastewater is described. It has been found that the great amount of sludge produced, the average value being 50 g of dry matter per inhabitant and per day, contains three species of pathogen microorganims: enteroviruses, bacteria and parasite eggs and cystes and that this microbial pollution is extremely harmful to human health. Therefore in order to manipulate as well as to use activated sludges in an agriculturad soil, a strong action against pathogen microorganisms is to be taken. Various treatment of sterilization are then described such as: pasteurization, incineration, liming, composting and by gamma radiations. The treatment by gamma radiations has been found to have many advantages in comparison with the other ones. An example of a sterilization plant located in Western Germany is given. (G.C.)

  13. A search for sterile neutrinos in MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Osiecki, Thomas Henry [Univ. of Texas, Austin, TX (United States)

    2007-01-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining Δm$2\\atop{23}$ and θ23 through the disappearance of vμ, MINOS is able to measure vμ → vsterile by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS.

  14. Sterile neutrinos in the early universe

    Energy Technology Data Exchange (ETDEWEB)

    Malaney, R.A. (Lawrence Livermore National Lab., CA (USA)); Fuller, G.M. (California Univ., San Diego, La Jolla, CA (USA). Dept. of Physics)

    1990-11-14

    We discuss the role played by right-handed sterile neutrinos in the early universe. We show how well known {sup 4}He constraint on the number of relativistic degrees of freedom at early times limits the equilibration of the right handed neutrino sea with the background plasma. We discuss how this allows interesting constraints to be placed on neutrino properties. In particular, a new limit on the Dirac mass of the neutrino is presented. 12 refs.

  15. Laparoscopic sterilization camps--a retrospection.

    Science.gov (United States)

    Mehta, P V

    1984-04-01

    Since the Indian introduction of mass rural laparoscopic sterilization camps the procedure has proved highly acceptable, economical, speedy, and safe. Despite many couples requiring sterilization, disturbing trends have emerged in many states relating to the organization of the camps, selection of cases, pre-operative preparation, adequate experience of the operating surgeon, inadequate drugs, improper maintainence, malfunctioning of equipment, and post-operative care and follow-up. During the initial phase, it was relatively easy to draw large crowds of self-motivated acceptors; the management of these crowds in small places left much to be desired. Camps are arranged without adequate publicity through the various media. The art of laparoscopy being a highly skilled technic, Steptoe has recommended at least 1000 procedures and Phillips 500 procedures in hospitals under expert supervision, before a laparoscopist can operate independently in camps. The equipment should be properly maintained and enough spares should be at hand. For the desired projection to stabilize the birth rate at 25/1000, the sterilization camps approach through quick, safe, economical, and easy laparoscopic sterilization technic is not a dream but a reality to be experienced. The vastness of the work requires many well trained doctors in this technic, who should be given exemption from income tax if they serve the rural population; thus, the brain drain will stop, and many emigrating doctors will be able to make a living. Overall, the commitment of policy makers to satisfy the masses who want to participate in this successful program is the only hope to save the bleak future.

  16. Sperm antibody production in female sterility.

    Science.gov (United States)

    Mettler, L; Scheidel, P; Shirwani, D

    1974-01-01

    A review of the immunological implications in reproductive physiology is presented. Although attempts have been made to ascribe the antigenicity of semen to individual components, it has not been possible to isolate the human semen antigen responsible for infertility. In monkeys total ejaculates and seminal plasma have shown higher antigenicity than washed spermatozoa. In bulls some evidence of such antigens have been found in the seminal plasma. They are iron-binding proteins resembling lactoferrin. Most investigators have found no evidence for any participation of the ABO blood group antigens in cases of sterility. On the surface of human spermatozoa histo-incompatibility antigens have been detected. Transplantation antigens may be related to sterility. However, an immulogic tolerance of the maternal organism exists against the genetically foreign fetal tissue. Autoimmune spermagglutinating antibodies have been detected in the sera and in the seminal plasma of males with sterility. An obstruction of the seminal pathways may facilitate the production of such antibodies against retained sperm. Isoimmunity in females against seminal components has been shown in cases of sterility; however, fertile women have also been shown to have such conditions. In a group of infertile women spermagglutination activity was detected in 7.5% of cases. In another series of 46 cases with primary unexplained infertility agglutinating antibodies were found in 17.4%. Other investigators have also reported higher rates than the authors. The sperm immobilization test seems to be more sensitive than the agglutination test. No sera were found positive with both tests. With immunofluorescent techniques humoral sperm antibodies have been found to be the IgM and IgG fractions. Each acts on a different part of the spermatozoa. The only promising therapy against humoral sperm antibodies is avoidance of sperm contact over a long period of time. Reported results have been conflicting. Cortisone

  17. Sterilization: new method options, failure rate info.

    Science.gov (United States)

    1998-01-01

    This article discusses new sterilization methods for tubal ligation, failure rates, and risks for ectopic pregnancy in the US. The Filshie clip, which was developed by Femcare, Ltd. in Nottingham, England, and is distributed by Avalon Medical Corp of Vermont, was approved by the US Food and Drug Administration in September 1996. The company has provided training sessions at major universities nationwide and exhibited at national professional association meetings. A training video and two more films will be available in 1998. The new clip is considered a more modern approach to a tubal occlusion method, which relies on newer materials and solves prior problems. Physicians usually used Falope rings, which had better failure rates than the Hulka clip and bipolar coagulation methods. There is a need for more long-term and large scale information exchange about the new Filshie clip. Some physicians still use the Falope ring because it is cost effective and well-studied. Physicians are warned to continue to advise women about the potential failure rates up to 10 years after sterilization and the 1 in 3 risk of ectopic pregnancy. Counseling about failure rates and the risk of ectopic pregnancy should target women under 30 years old, who have the highest failure rates, and women 30-34 years old. All sterilized women should be advised to seek a provider immediately if they have pregnancy symptoms following sterilization. Counseling should include the issue of "regrets," since it is a permanent method. All women should know about nonpermanent methods and experience a basic informed consent process. Young women and newly divorced women are particularly vulnerable to the "regrets" syndrome.

  18. Sterilization potential of contact lens solutions

    OpenAIRE

    Dada Vijay; Mehta Manoj

    1988-01-01

    In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. ...

  19. Dose mapping for documentation of radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1999-01-01

    The radiation sterilization standards EN 552 and ISO 11137 require that dose mapping in real or simulated product be carried in connection with the process qualification. This paper reviews the recommendations given in the standards and discusses the difficulties and limitations of practical dose...... mapping. The paper further gives recommendations for effective dose mapping including traceable dosimetry, documented procedures for placement of dosimeters, and evaluation of measurement uncertainties. (C) 1999 Elsevier Science Ltd. All rights reserved....

  20. Light Sterile Neutrinos from Large Extra Dimensions

    OpenAIRE

    Ma, Ernest; Rajasekaran, G.; Sarkar, Utpal

    2000-01-01

    An experimentally verifiable Higgs-triplet model of neutrino masses from large extra dimensions was recently proposed. We extend it to accomodate a light sterile neutrino which also mixes with the three active neutrinos. A previously proposed phenomenological model of four neutrinos (\\underline {the only viable such model now left}, in view of the latest atmospheric and solar neutrino-oscillation data) is specifically realized.

  1. Irradiation sterilization of semi-crystalline polymers

    International Nuclear Information System (INIS)

    Williams, J.; Dunn, T.; Stannett, V.

    1978-01-01

    A semi-crystalline polymer such as polypropylene, is sterilized by high energy irradiation, with the polymer containing a non-crystalline mobilizing additive which increases the free volume of the polymer, to prevent embrittlement of the polymer during and subsequent to the irradiation. The additive has a density of from 0.6 to 1.9 g/cm 3 and a molecular weight from 100 to 10,000 g/mole

  2. Psychosexual adjustment following sterilization: a prospective study on Chinese women.

    Science.gov (United States)

    Tang, C S; Chung, T K

    1997-02-01

    The present study aimed to identify significant predictors of Chinese women's psychosexual adjustment after sterilization. One hundred fifteen multiparous Chinese women, aged 25-51 years, were interviewed before and after elective laparoscopic or postpartum sterilization. Eight-seven women were also interviewed about their pshychosexual adjustment at 1 year after sterilization. Results showed that the fear of negative evaluation by others, family cohesion and adaptability, and preoperative psychological distress were robust predictors of adverse psychosexual outcome immediately and 1 year after sterilization. There was significant improvement in women's mental health following sterilization, and their sexual adjustment such as coital frequency and sexual satisfaction were not adversely affected at 1 year follow-up. Women with either elective or postpartum sterilization had similar adjustment throughout, except the latter group tended to experience more physical discomfort at 1 year follow-up. About 3.4% of the women experienced regret at 12 months after sterilization.

  3. [Essure--a novel method of sterilization].

    Science.gov (United States)

    Revel, Ariel; Nadjary, Michel; Shushan, Asher

    2008-02-01

    Essure hysteroscopic sterilization is a minimally invasive, outpatient approach to female sterilization, which avoids the possible complications of laparoscopic sterilization. This procedure has been available since 2003 in both Europe and North America. We present our experience of the first 12 cases of the procedure performed in Israel. Women who have completed their family planning were offered to consider Essure as their permanent contraception. The procedure was performed without anesthesia by the vaginoscopic technique at the hospital's outpatient clinic. Patients completed a questionnaire and were discharged immediately following the procedure. A follow-up checkup was completed after three months including three dimensional sonography, abdominal X-ray and occasional hysterosalpingogram. Twelve patients participated in the pilot group at Hadassah. The average age was 40 years (34-45) and the average number of children was 5 (4-8). The average time for the procedure was under 8 minutes. Periostial adhesions required adhesiolysis prior to insertion of the device in one patient. All patients resumed their normal activity on the same day. Our patient satisfaction survey revealed that the procedure was associated with high satisfaction levels. Sonographic and radiographic studies confirmed the good placement of the device. The Essure procedure was well tolerated by patients. The limitation is probably going to be the price of Essure, as this procedure is not covered by the 'health basket' in Israel.

  4. Sterilization by ionizing radiation comparative evaluation

    International Nuclear Information System (INIS)

    Tata, A.; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 7 on beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems

  5. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  6. Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection - An In-vitro Study.

    Science.gov (United States)

    Raju, T B V G; Garapati, Satish; Agrawal, Rupika; Reddy, Sridhara; Razdan, Ankur; Kumar, S Kishore

    2013-12-01

    Aim of the study was to compare 4 different methods of sterilizing endodontic files in dental practice. The present study was performed on 100 K-files, 21 mm long and of size 25. Of these, 20 files were taken as control group, and the remaining 80 files were divided into 4 groups of 20 files each and they were tested for the efficacy of sterilization with different methods: Autoclave, glass bead, glutaraldehyde and CO2 laser. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization. How to cite this article: Raju TB, Garapati S, Agrawal R, Reddy S, Razdan A, Kumar SK. Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection - An In-vitro Study. J Int Oral Health 2013; 5(6):108-12 .

  7. Sensitivity of viruses to radiation sterilization

    International Nuclear Information System (INIS)

    Dziedzic Goclawska; A

    1999-01-01

    The hazard of infectious disease transmission with tissue allografts is a major concern in tissue banking practice. Microorganisms can be introduced into grafts during tissue collection, processing and storage, but even when all these procedures are performed under a septic conditions, the possibility of fungal, bacterial or viral disease transmission of donor origin can not be excluded. Therefore, in order to minimize the risk of infectious disease transmission, several steps should be undertaken, including a careful donor screening, proper tissue processing and sterilization of tissue allografts. The risk of transmission of viral infections such as hepatitis B, C, other viruses and particularly HIV with tissue allografts is of great significance and the search for sterilizing methods which inactivate and/or highly reduce viral infectivity continues. Sterilization of tissue allografts with ionizing radiation (introduced in the mid of 1950s) is increasingly used in tissue banking practice. The effectiveness of the radiation-sterilization procedure depends on the amount of energy transferred, the number of contaminating microorganisms and their resistance to ionizing radiation (initial contamination, bioburden). Usually, spores are more resistant than vegetative forms of bacteria, some fungi may be as resistant as bacterial spores, and viruses are, in general, more resistant than bacteria. Dita concerning effectiveness of ionizing radiation to inactivate viruses (e.g. such as HBV, HCV or HIV) in tissue allografts collected from cadavers are scarce. It has been found that the dose of irradiation needed to reduce HIV load by I log10 unit (D10) is about 4.0 kGy or even 5.6 kGy. The level of infectious HIV in plasma is usually evaluated by titration of tissue culture infective dose (TCID50/ml). Taking into consideration the recommended sterility assurance level (SAL) 10-6, assuming the HIV bioburden to be 103 TCID50/ml for the state of acute infection and D10 value of 4

  8. Electron sterilization validation techniques using the controlled depth of sterilization process

    Science.gov (United States)

    Cleghorn, Denise A.; Nablo, Sam V.

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. most of these products are filled under aseptic conditions so that for qualification as a sterile product, techniques are often required only for treatment of the container surfaces and package interior. Gas sterilization (ETO) is often used for this purpose but is beset with difficulties known to the reader, especially for critical "contact" products such as in the ophthalmic field. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and x-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating x-ray dose ratios are possible for the application of the technique. Some of these data illustrating package: parenteral ratios of 10 5:1 have been reported (Rangwalla et al, 1985; Aaronson and Nablo, 1988). Standard techniques have been developed for the validation of the process and are reported here. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed.

  9. Use of sterile insect technique in Brazil by the sterilization of Ceratitis capitata (Wied., 1824)

    International Nuclear Information System (INIS)

    Okeese, G.O.; Kitomer, T.J.; Gayaradus, L.B.; Etrigan, M.; Jansen, C.W.J.H.; Houlahar, H.L.

    2006-01-01

    The Sterile Insect Technique is a method of pest control allowed in Integrated Pest Management programs in fruit growing, where sterile insects released compete in mate process against fertile wild ones, generating a gradative population reduction. The most used sterilization method is using ionizing radiation from 60 Co or 137 Cs. For efficient application of SIT, an important item is the sterilizing dose. This must be as lower as possible in order to preserve insect behavior. In this work, it was studied the reproductive potential of fruit fly Ceratitis capitata, tsl VIENNA 8 strain, irradiated with different doses of gamma radiation. This strain has been used in population suppression programs at fruit-growing areas from Northeast of Brazil, through a partnership between CENA and Bio factory MOSCAMED Brazil, intending only sterile male releases. Radiation source used was a 60 Co irradiator, with 17.2 x 1012 Bq. Individualized couples were distributed in a randomized delineament with 10 replicates for each treatment and eggs were collected for fifteen days. With 9 and 10 days old, pupae were irradiated with doses ranging from 30 to 120 Gy. All averages of emerged adult's percentages were higher than 90%. In regards to fecundity, different doses did not affect the number of eggs laid, being the overall mean around 30 eggs/couple/day. Fertility data showed that as radiation dose increases, sterility increases. It was concluded that the dose of 90 Gy can be used in Brazil, since to SIT programs a dose is chosen witch prevents an egg hatch higher than 1%. (author)

  10. Degradation of chitosan-based materials after different sterilization treatments

    Science.gov (United States)

    San Juan, A.; Montembault, A.; Gillet, D.; Say, J. P.; Rouif, S.; Bouet, T.; Royaud, I.; David, L.

    2012-02-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  11. Degradation of chitosan-based materials after different sterilization treatments

    International Nuclear Information System (INIS)

    San Juan, A; Montembault, A; Royaud, I; David, L; Gillet, D; Say, J P; Rouif, S; Bouet, T

    2012-01-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  12. Obstetric Outcomes After Failed Hysteroscopic and Laparoscopic Sterilization Procedures.

    Science.gov (United States)

    Brandi, Kristyn; Morgan, Jake R; Paasche-Orlow, Michael K; Perkins, Rebecca B; White, Katharine OʼConnell

    2018-02-01

    To compare obstetric outcomes after failed hysteroscopic and laparoscopic sterilization. This retrospective cohort study examined pregnancy outcomes including live birth, preterm birth, stillbirth, spontaneous abortion, therapeutic abortion, ectopic pregnancies, and gestational trophoblastic disease using a commercial claims administrative database for the years 2007-2013. We used a Z-test to compare pregnancy outcomes per 100 person-years based on type of sterilization. Cox proportional hazard models controlled for patient age, geographic region, urbanicity, comorbidities, and insurance type. We evaluated 997 pregnancy outcomes among 817 women from a total of 70,115 women with a history of either hysteroscopic sterilization (n=387 pregnancies/27,724 cases) or laparoscopic sterilization (n=610 pregnancies/42,391 cases). Women undergoing hysteroscopic sterilization were slightly older than, but otherwise similar to, women undergoing laparoscopic sterilization. The most common outcome was live birth, which was more likely after hysteroscopic sterilization compared with laparoscopic sterilization (adjusted hazard ratio 1.32, 95% CI 1.09-1.60). The rate of spontaneous abortion was not statistically significantly different between the two groups. Therapeutic abortion occurred more often after hysteroscopic sterilization (adjusted hazard ratio 1.49, 95% CI 1.10-2.01), whereas ectopic pregnancies occurred less often (adjusted hazard ratio 0.12, 95% CI 0.05-0.29) compared with laparoscopic sterilization. Hysteroscopic sterilization is associated with higher rates of live birth and lower rates of ectopic pregnancy compared with laparoscopic sterilization. Spontaneous abortion and preterm birth rates were similar in both groups. These data do not support an adverse effect of hysteroscopic sterilization on subsequent pregnancy outcomes.

  13. Economic aspects of radiosterilization; Aspekty ekonomiczne sterylizacji radiacyjnej

    Energy Technology Data Exchange (ETDEWEB)

    Zimek, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    The economic analysis of radiosterilization have been done. The costs have been estimated on the example of Electron Accelerator Irradiation Plant for Radiosterilization working in Institute of Nuclear Chemistry and Technology, Warsaw. 3 tabs.

  14. Electron accelerators for radiosterilization; Akceleratory elektronow dla potrzeb sterylizacji radiacyjnej

    Energy Technology Data Exchange (ETDEWEB)

    Zimek, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    The applications of electron accelerators in commercial plants for radiosterilization have been shown. Advantages of such irradiation source have been presented. The types and parameters of accelerators being installed in worldwide irradiation plants for radiosterilization have been listed as well. 2 tabs.

  15. Egzemplifikacja Tomograficznej Metody Do Oceny Jakości Połączeń Spawanych Ze Stopu EN 5754 H22

    Directory of Open Access Journals (Sweden)

    Błachnio Józef

    2016-12-01

    Full Text Available Jakość połączeń spawanych zależna jest od wielu czynników. Przedmiotowe normy określają warunki techniczne oceny jakościowej spawów, co stanowi podstawę do uznania połączenia za zgodne z wymaganiami lub wadliwe. W praktyce wykonanie połączenia spawanego całkowicie pozbawionego wad jest trudne. Do kontroli wewnętrznej struktury połączenia wykorzystać można nieniszczącą metodę z zastosowaniem przemysłowego tomografu komputerowego. Ta nowoczesna metoda diagnozowania łączy badanie rentgenowskie z zaawansowaną technologią komputerową. Podstawową zaletą tomografii komputerowej jest badanie obiektów w trzech wymiarach oraz możliwość wykonania rekonstrukcji przestrzennych. Celem artykułu jest omówienie wykorzystania tej metody do oceny jakości połączeń spawanych stopów aluminium. Możliwości tomografii komputerowej przedstawiono na przykładzie próbek spawalniczych wykonanych metodą TIG przy różnych parametrach procesu. Dokonano analizy jakości próbek wykazujących najmniejsze i największe zewnętrzne, jak również wewnętrzne wady spawalnicze.

  16. Supercritical carbon dioxide-based sterilization of decellularized heart valves

    Science.gov (United States)

    Hennessy, Ryan S.; Jana, Soumen; Tefft, Brandon J.; Helder, Meghana R.; Young, Melissa D.; Hennessy, Rebecca R.; Stoyles, Nicholas J.; Lerman, Amir

    2017-01-01

    Objective The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Background Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Methods Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Results Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Conclusions Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Summary Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated

  17. Plant's sterilization rule for fertile women cited.

    Science.gov (United States)

    1979-01-01

    The American Cyanamid Corporation has been cited by the Occupational Safety and Health Administration (OSHA) for violating federal law by requiring female employees of childbearing age to be sterilized in order to continue working in areas of the plant where they would be exposed to high levels of airborne lead. High levels of airborne lead can cause damage to workers' reproductive systems and be responsible for birth defects in fetuses. The OSHA charged that American Cyanamid's policy constituted a "willful violation" of the 1970 Occupational Safety and Health Act. The Act requires employers to provide employment that is free from recognized hazards likely to cause death or physical harm. According to OSHA, the Act does not allow an employer to eliminate the hazard by compelling employees to choose between losing their jobs and undergoing sterilization. The reproductive health of workers is considered a valid part of OSHA's regulatory concern. The citation, which carries a $10,000 fine, grew out of a complaint that was filed by the Oil, Chemical and Atomic Workers Union on behalf of 5 female workers working in the lead pigment division of the company's Willow Island, West Virginia plant. The 5 employees alleged that they had themselves sterilized to avoid being transferred to other and possibly lower paying janitorial jobs or losing thier jobs completely. The company is appealing the citation. The union has also filed a complaint with the Equal Employment Opportunity Commission charging American Cyanamid with sex discrimination, since only the women workers are at risk of being transferred to lower paying jobs.

  18. Environment and the sterile insect technique

    International Nuclear Information System (INIS)

    Nagel, P.; Peveling, R.

    2005-01-01

    The sterile insect technique (SIT) is an exceptionally promising pest control method in terms of efficacy and environmental compatibility. Assessments of environmental risks vary according to the status and origin of the target pests. The suppression or eradication of exotic pest populations with the SIT raises few environmental concerns, and these are related mainly to pre-release suppression techniques. However, the elimination of native species, or at least populations of native species, requires more detailed and complex assessments of ecological effects and consequences for biodiversity conservation. Eradication programmes provide opportunities to study these topics within the scope of both environmental impact assessments and operational monitoring programmes. (author)

  19. Sterile neutrinos and B-L symmetry

    Science.gov (United States)

    Fileviez Pérez, Pavel; Murgui, Clara

    2018-02-01

    We revisit the relation between the neutrino masses and the spontaneous breaking of the B-L gauge symmetry. We discuss the main scenarios for Dirac and Majorana neutrinos and point out two simple mechanisms for neutrino masses. In this context the neutrino masses can be generated either at tree level or at quantum level and one predicts the existence of very light sterile neutrinos with masses below the eV scale. The predictions for lepton number violating processes such as μ → e and μ → eγ are discussed in detail. The impact from the cosmological constraints on the effective number of relativistic degree of freedom is investigated.

  20. Sterile searches with Liquid Argon at FNAL

    CERN Document Server

    Raselli, Gian Luca

    2017-01-01

    A new Short Baseline Neutrino (SBN) experiment is in preparation at FNAL to definitely prove or exclude the existence of non-standard neutrino oscillations into sterile states. The program foresees the deployment along the Booster Neutrino Beam (BNB) of three detectors, all based on the liquid-argon time projection chamber technique. This technology has been taken to full maturity with ICARUS T600, which will act as far detector after the completion of the overhauling at CERN and its transportation to FNAL. The program foresees the data taking for three years.

  1. Sterilization potential of contact lens solutions

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1988-01-01

    Full Text Available In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. It was observed that the contact lens solutions available ir, the domestic market were not upto the mark Suggestions for improvement have also been made.

  2. Processing laboratory of radio sterilized biological tissues

    International Nuclear Information System (INIS)

    Aguirre H, Paulina; Zarate S, Herman; Silva R, Samy; Hitschfeld, Mario

    2005-01-01

    The nuclear development applications have also reached those areas related to health. The risk of getting contagious illnesses through applying biological tissues has been one of the paramount worries to be solved since infectious illnesses might be provoked by virus, fungis or bacterias coming from donors or whether they have been introduced by means of intermediate stages before the use of these tissues. Therefore it has been concluded that the tissue allografts must be sterilized. The sterilization of medical products has been one of the main applications of the ionizing radiations and that it is why the International Organization of Atomic Energy began in the 70s promoting works related to the biological tissue sterilization and pharmaceutical products. The development of different tissue preservation methods has made possible the creation of tissue banks in different countries, to deal with long-term preservation. In our country, a project was launched in 1998, 'Establishment of a Tissue Bank in Latino america', this project was supported by the OIEA through the project INT/ 6/ 049, and was the starting of the actual Processing Laboratory of Radioesterilized Biological Tissues (LPTR), leaded by the Chilean Nuclear Energy Commission (CCHEN). This first organization is part of a number of entities compounding the Tissue Bank in Chile, organizations such as the Transplantation Promotion Corporation hospitals and the LPTR. The working system is carried out by means of the interaction between the hospitals and the laboratory. The medical professionals perform the procuring of tissues in the hospitals, then send them to the LPTR where they are processed and sterilized with ionizing radiation. The cycle ends up with the tissues return released to the hospitals, where they are used, and then the result information is sent to the LPTR as a form of feedback. Up to now, human skin has been processed (64 donors), amniotic membranes (35 donors) and pig skin (175 portions

  3. American Sterilization: The Racist Justifications for Sterilization in the United States

    OpenAIRE

    Trevor Price

    2016-01-01

    An investigative analysis into anthropometrics, sterilization, eugenics, and other forms of scientific racism used to justify white supremacy and racial thought in the 19th and 20th centuries in the United States. The Tuskegee syphilis study, Darwinistic ideals, and neo-Lamarckian thoughts are critically analyzed as justifications for institutional racism.

  4. Electron sterilization validation techniques using the controlled depth of sterilization process

    International Nuclear Information System (INIS)

    Cleghorn, D.A.; Nablo, S.V.

    1990-01-01

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and X-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating X-ray dose ratios are possible for the application of the technique. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed. (author)

  5. Reliability of laparoscopic compared with hysteroscopic sterilization at 1 year: a decision analysis.

    Science.gov (United States)

    Gariepy, Aileen M; Creinin, Mitchell D; Schwarz, Eleanor B; Smith, Kenneth J

    2011-08-01

    To estimate the probability of successful sterilization after an hysteroscopic or laparoscopic sterilization procedure. An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. In the base case analysis, the proportion of women having a successful sterilization procedure on the first attempt is 99% for laparoscopic sterilization, 88% for hysteroscopic sterilization in the operating room, and 87% for hysteroscopic sterilization in the office. The probability of having a successful sterilization procedure within 1 year is 99% with laparoscopic sterilization, 95% for hysteroscopic sterilization in the operating room, and 94% for hysteroscopic sterilization in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within 1 year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization.

  6. Study of male sterility in Taiwania cryptomerioides Hayata (Taxodiaceae).

    Science.gov (United States)

    Chen, S-H; Chung, N-J; Wang, Y-N; Lee, C-L; Lee, Y-L; Tsai, P-F

    2006-08-01

    A study of male sterility over a period of three consecutive years on a conifer species endemic to Taiwan, Taiwania cryptomerioides Hayata (Taxodiaceae), was done for this article. With the aids of fluorescence and electron microscopic observations, the ontogenic processes in the fertile and sterile microsporangia are compared, using samples collected from Chitou Experimental Forest and Yeou-Shoei-Keng Clonal Orchard of the National Taiwan University, Nantou, Taiwan. The development of male strobili occurred from August to the end of March. Microsporogenesis starts with the formation of the archesporium and ends with the maturation of 2-celled pollen grains within the dehiscing microsporangium. Before meiosis, there was no significant difference in ultrastructure between the fertile and sterile microsporangia. Asynchronous pollen development with various tetrad forms may occur in the same microsporangium of either fertile or sterile strobili. However, a callose wall was observable in the fertile dyad and tetrad, but not in the sterile one. After dissolution of the callose wall, the fertile microspores were released into the locule, while some sterile microspores still retained as tetrads or dyads with intertwining of exine walls in the proximal faces. As a result, there was no well developed lamellated endexine and no granulate ectexine or intine in the sterile microspores. Eventually, the intracellular structures in sterile microspores were dramatically collapsed before anthesis. The present study shows that the abortion in pollen development is possibly attributed to the absence of the callose wall. The importance of this structure to the male sterility of T. cryptomerioides is discussed.

  7. Genetic expression of induced rice sterility under alien-cytoplasm

    International Nuclear Information System (INIS)

    Wang Naiyuan; Cai Zhijun; Liang Kangjing; Li Yu

    2005-01-01

    Rice restorer lines were treated with 60 Co γ-ray and 4 male sterile mutants obtained with the fertility of controlled by 4 non-allelic recessive genes, respectively. Sixty combinations were made by using male sterile plants/fertile plants as male parents, and 15 different cytoplasmic substitution lines of the same cell nucleus as female parents. The result showed that F 1 spikelets were normal and fertile, and different numbers of male sterile plants were segregated in F 2 . Complete fertility genotype was not found among interactions between induced male sterile genes and alien-cytoplasms. (authors)

  8. Dark matter relic abundance and light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi-Lei [Center for High Energy Physics,Peking University, Beijing 100871 (China); Zhu, Shou-hua [Center for High Energy Physics,Peking University, Beijing 100871 (China); Institute of Theoretical Physics & State Key Laboratory of Nuclear Physics and Technology,Peking University, Beijing 100871 (China); Collaborative Innovation Center of Quantum Matter,Beijing 100871 (China)

    2017-01-09

    In this paper, we calculate the relic abundance of the dark matter particles when they can annihilate into sterile neutrinos with the mass ≲100 GeV in a simple model. Unlike the usual standard calculations, the sterile neutrino may fall out of the thermal equilibrium with the thermal bath before the dark matter freezes out. In such a case, if the Yukawa coupling y{sub N} between the Higgs and the sterile neutrino is small, this process gives rise to a larger Ω{sub DM}h{sup 2} so we need a larger coupling between the dark matter and the sterile neutrino for a correct relic abundance.

  9. Eugenics, sterilization, and historical memory in the United States.

    Science.gov (United States)

    Stern, Alexandra Minna

    2016-12-01

    From the 1920s to the 1950s, California sterilized approximately 20,000 people in state homes and hospitals based on a eugenic law that authorized medical superintendents to perform reproductive surgeries on patients deemed unfit and "suffering from a mental affliction likely to be inherited." Working with a unique resource - a dataset created from 19,000 sterilization recommendations - my team and I have reconstructed patterns and experiences of institutionalization of sterilizations. This article presents several of our important initial findings related to ethnic and gender bias in sterilization policies, and reflects on the relevance of the history for contemporary issues in genomics and social justice.

  10. System and method of applying energetic ions for sterilization

    Science.gov (United States)

    Schmidt, John A.

    2003-12-23

    A method of sterilization of a container is provided whereby a cold plasma is caused to be disposed near a surface to be sterilized, and the cold plasma is then subjected to a pulsed voltage differential for producing energized ions in the plasma. Those energized ions then operate to achieve spore destruction on the surface to be sterilized. Further, a system for sterilization of a container which includes a conductive or non-conductive container, a cold plasma in proximity to the container, and a high voltage source for delivering a pulsed voltage differential between an electrode and the container and across the cold plasma, is provided.

  11. ACOG Practice bulletin no. 133: benefits and risks of sterilization.

    Science.gov (United States)

    2013-02-01

    Female and male sterilization are both safe and effective methods of permanent contraception used by more than 220 million couples worldwide . Approximately 600,000 tubal occlusions and 200,000 vasectomies are performed in the United States annually . For women seeking permanent contraception, sterilization obviates the need for user-dependent contraception throughout their reproductive years and provides an excellent alternative for those with medical contraindications to reversible methods. The purpose of this document is to review the evidence for the safety and effectiveness of female sterilization in comparison with male sterilization and other forms of contraception.

  12. Sterile neutrino searches via displaced vertices at LHCb

    Science.gov (United States)

    Antusch, Stefan; Cazzato, Eros; Fischer, Oliver

    2017-11-01

    We explore the sensitivity of displaced vertex searches at LHCb for testing sterile neutrino extensions of the Standard Model towards explaining the observed neutrino masses. We derive estimates for the constraints on sterile neutrino parameters from a recently published displaced vertex search at LHCb based on run 1 data. They yield the currently most stringent limit on active-sterile neutrino mixing in the sterile neutrino mass range between 4.5 GeV and 10 GeV. Furthermore, we present forecasts for the sensitivities that could be obtained from the run 2 data and also for the high-luminosity phase of the LHC.

  13. Gene, protein and network of male sterility in rice

    Directory of Open Access Journals (Sweden)

    Wang eKun

    2013-04-01

    Full Text Available Rice is one of the most important model crop plants whose heterosis has been well exploited in commercial hybrid seed production via a variety of types of male sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and proteins related to cytoplasmic male sterility, photoperiod sensitive male sterility, self-incompatibility and other types of microspores deterioration have been characterized through genetics or proteomics. Especially the latter, offers us a powerful and high throughput approach to discern the novel proteins involving in male-sterile pathways which may help us to breed artificial male-sterile system. This represents an alternative tool to meet the critical challenge of further development of hybrid rice. In this paper, we reviewed the recent developments in our understanding of male sterility in rice hybrid production across gene, protein and integrated network levels, and also, present a perspective on the engineering of male sterile lines for hybrid rice production.

  14. Sterilization of biological tissues with ionizing radiation

    International Nuclear Information System (INIS)

    Reyes F, M.L.; Martinez P, M.E.; Luna Z, D.

    1997-01-01

    On June 1994, the National Institute of Nuclear Research (ININ) and the South Central Hospital for High Specialty of PEMEX (HCSAE) began a joint work with the finality to obtain radio sterilized amniotic membranes for to be used as cover (biological bandage) in burnt patients. Subsequently the Chemistry Faculty of UNAM and the National Institute of Cardiology began to collaborate this last with interest on cardiac valves for graft. Starting from 1997, the International Atomic Energy Agency (IAEA) supports this project (MEX/7/008) whose main objective is to set up the basis to establish in Mexico a Radio sterilized Tissue Bank (amniotic membranes, skin, bones, tendons, cardiac valves, etc.) to be used with therapeutic purposes (grafts). The IAEA support has consisted in the equipment acquisition which is fundamental for the Tissue Bank performance such as an experimental irradiator, laminar flow bell, lyophilizer, vacuum sealer and special knives for tissues. Also visits to Mexico of experts have been authorized with the aim of advising to the personnel which participate in the project and scientific visits of this personnel to another tissue banks (Sri Lanka and Argentine). The establishment in Mexico of a Tissue bank will be a great benefit because it will have availability of distinct tissues for grafts and it will reduce the synthetic materials importation which is very expensive. (Author)

  15. Sterile Neuroinflammation and Strategies for Therapeutic Intervention

    Directory of Open Access Journals (Sweden)

    Manoj Banjara

    2017-01-01

    Full Text Available Sterile neuroinflammation is essential for the proper brain development and tissue repair. However, uncontrolled neuroinflammation plays a major role in the pathogenesis of various disease processes. The endogenous intracellular molecules so called damage-associated molecular patterns or alarmins or damage signals that are released by activated or necrotic cells are thought to play a crucial role in initiating an immune response. Sterile inflammatory response that occurs in Alzheimer’s disease (AD, Parkinson’s disease (PD, stroke, hemorrhage, epilepsy, or traumatic brain injury (TBI creates a vicious cycle of unrestrained inflammation, driving progressive neurodegeneration. Neuroinflammation is a key mechanism in the progression (e.g., AD and PD or secondary injury development (e.g., stroke, hemorrhage, stress, and TBI of multiple brain conditions. Hence, it provides an opportunity for the therapeutic intervention to prevent progressive tissue damage and loss of function. The key for developing anti-neuroinflammatory treatment is to minimize the detrimental and neurotoxic effects of inflammation while promoting the beneficial and neurotropic effects, thereby creating ideal conditions for regeneration and repair. This review outlines how inflammation is involved in the pathogenesis of major nonpathogenic neuroinflammatory conditions and discusses the complex response of glial cells to damage signals. In addition, emerging experimental anti-neuroinflammatory drug treatment strategies are discussed.

  16. Antiophidian sera sterility control: topics in perspective

    Directory of Open Access Journals (Sweden)

    Paula Gomes Santos

    2009-09-01

    Full Text Available The aim of this work is to review the most important topics about the antiophidic sera sterility, including obtaining methods, sterilization procedures and clean room control using Vital Brazil Institute (VBI as an example. Bibliographical research was performed through Medline, Lilacs, PubMed, ISI and the Fundação Oswaldo Cruz - RJ and VBI Libraries, from 1960 to 2009. The antiophidic sera for human use are immunobiologic products produced in Brazil by three national laboratories, including VBI. Due to the parenteral use, these products should be sterile and pyrogen-free, which demands the microbiological control during the whole fabrication process. The sterility and pyrogen tests are important steps to ensure the quality and safety of these immunobiological products. Thus, these tests are target for continue evaluation and improvement. The most interfering aspects in the consistency and analytical patterns include the proper method selection, sampling, culture conditions and validation criteria. As the national and international legal requirements are cautious with the assays validation and approval of sterile parenteral products; the intrinsic limitations for established assays still require more investigation aiming the continue improvement of the microorganism and contaminants detection methods and optimization of the analysis extent.O objetivo deste trabalho é revisar os tópicos mais relevantes para o controle da esterilidade de soros antiofídicos, abordando-se métodos de obtenção, procedimentos de esterilização e o controle de áreas limpas utilizando como exemplo os procedimentos adotados pelo Instituto Vital Brazil (IVB. Um levantamento bibliográfico foi realizado no Medline, ISI, Biblioteca da Fundação Oswaldo Cruz-RJ e IVB, no período de 1960 a 2009. Os soros antiofídicos para uso humano são produtos imunobiológicos fabricados no Brasil por três laboratórios nacionais, dentre eles o IVB. Por serem de administra

  17. Why are rates of sterilization in decline? A pilot study designed to explore reasons for declining female sterilization in Scotland.

    Science.gov (United States)

    Chen, Zhong E; Glasier, Anna; Warner, Pamela

    2008-10-01

    In the last decade, female sterilization had been in decline throughout the UK. It is not clear whether fewer women are requesting sterilization or whether the universal enthusiasm for long-acting reversible methods is leading health professionals to discourage women from being sterilized. Since correct and consistent use of alternative, reversible contraceptive methods depends somewhat on their acceptability, it is important to determine whether women are being refused sterilization or whether they are freely choosing other methods. This study aims to explore whether female sterilization is being widely considered as a contraceptive method, the reasons for choosing or rejecting it, and whether women are being discouraged by health professionals from being sterilized. A self-completed questionnaire survey among 205 women aged 30 to 50 years who felt that their family was complete attending a family planning clinic in Scotland. Of the 203 women included in the study, 151 (74.4%) had heard of female sterilization, 90 had discussed it with someone (60%) and 87 (58%) had considered it as a contraceptive option. Of the 56 women who consulted their family doctor about sterilization, almost half (27; 48%) were not referred to a hospital and fewer than one (17, 30.4%) in three of them was eventually sterilized or had arrangements in place to get it done. Free-text comments from the women revealed a variety of reasons for not choosing female sterilization and suggested that some women are being deterred from sterilization. The study suggests that some women are being actively encouraged by health professionals to use long-acting reversible contraceptive methods and discouraged from choosing sterilization. However, other women recognize for themselves the wisdom of keeping their fertility options open.

  18. Fertility and reproductive history of sterilized and non-sterilized women in Campinas, São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Maria José Duarte Osis

    Full Text Available This article compares sterilized and non-sterilized women in relation to socio-demographic characteristics, reproductive history, and cohabitation status. Women from 30 to 49 years of age and residing in Campinas, São Paulo State, Brazil, were interviewed with a pre-tested and structured questionnaire: 236 women sterilized at least five years before the interview and 236 non-sterilized women. The sterilized women were significantly more likely to be married or cohabiting, to be younger when they began cohabiting, and to have been in the union longer than the non-sterilized women. They also began childbearing at an earlier age and had a history of more pregnancies and more live births than non-sterilized women. Factors associated with a history of 3 or more live births at the time of the interview were surgical sterilization, younger age at first childbirth, older age at the interview, recognition of fewer contraceptive methods, and lower per capita income. The article concludes that sterilization generally appears to be the consequence of higher fertility in a group of women who initiate childbearing early in life, although its role in preventing these women from having even larger families may also have a demographic impact.

  19. Sterilization of fruit flies (Diptera: Tephritidae) with X-rays for sterile insect technique programs

    International Nuclear Information System (INIS)

    Mastrangelo, Thiago de Araujo

    2009-01-01

    Recent fear of acts of terrorism provoked an increase of delays and denials in the shipment of radioisotopes. This truly represented a menace to sterile insect production projects around the world. In order to validate the use of a new kind of low-energy Xray irradiator, a series of radiobiological studies on Ceratitis capitata (tsl-VIENNA 8 strain) (Wied., 1824) (Diptera: Tephritidae) and an Argentinean strain of Anastrepha fraterculus (Wied., 1830) (Diptera: Tephritidae) were carried out, also comparing biological effectiveness between X-rays and traditional γ radiation from 60 Co. Pupae 48- 24 h before adult emergence of C. capitata males and both sexes of A. fraterculus were irradiated with doses ranging from 15 to 120 Gy and 10 to 70 Gy respectively. Doses that induce 50, 90 and 99% of sterility were estimated and the hypothesis of Parallelism for the Probit equations was tested. Doses of 82.7 Gy of X-rays and 128.2 Gy of γ rays (thus, a RBE∼1.5) induced 99% sterility on medfly males. The fertility of A. fraterculus fertile females crossed with 41 Gy of X-rays and 62.7 Gy of γ rays decreased in 99% comparing with the control group (RBE∼1.5). 99% sterility of A. fraterculus irradiated females was achieved with 60-80 Gy (RBE∼0.7). The standard quality control parameters of fecundity, adult emergence, fliers and survival were not significantly affected by the two types of radiation (RBE∼1) either for medfly or A. fraterculus (p>0.01), being averages in conformity with the values required by FAO/IAEA/USDA. Only fecundity of irradiated A. fraterculus females was severely reduced with increasing doses and no egg was laid at 70 Gy of both radiations. There were no significant differences between X-rays and γ rays regarding mating indices (RSI for medfly, RII, ISI, MRPI and FRPI for A. fraterculus) (p>0.05), what indicated more random matings for fertile and sterile insects. The results demonstrated that no significant difference in biological

  20. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Krishnan, Vijaya

    2004-01-01

    Full Text Available EnglishPrior to early 1970s, traditional methods were the principal means ofcontrolling the number and spacing of births. Today, an estimated 57 per cent of the world's marriedwomen use contraceptives and half use modern methods such as medical sterilizations. Recent statisticssuggest that Canada has the highest sterilization rate in the Western world. This paper presentsfindings of research examining sterilization trends in Canada with respect to changing patterns in theuse of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligationand an increase in the use of hysterectomy over the period 1984-1995. Less educated women are morelikely to be in the forefront of modern methdos of contraception.FrenchAvant les années 1970, les méthodes traditionnelles représentaient le principalmoyen de contrôler et d’espacer le nombre de naissances. De nos jours, onestime que 57 pour cent des femmes mariées dans le monde entier utilisent unmoyen contraceptif et la moitié utilise des méthodes modernes telles que lastérilisation. Les dernières statistiques indiquent que le Canada compte le tauxde stérilisations le plus élevé dans le monde occidental. Cet article présente lesconclusions de recherches portant sur les tendances en matière de stérilisation auCanada en ce qui concerne les modèles changeants d’utilisation de moyens decontraception modernes et ce, à partir de données de l’Enquête canadienne sur lafécondité de 1984 et de l’Enquête sociale générale (ESG de 1995. La principaleconclusion qui en est ressortie est une réduction de la ligature des trompes etune augmentation du nombre d’hystérectomies de 1984 à 1995. Les femmesmoins éduquées sont plus portées à se trouver au premier plan des méthodes decontraception modernes.

  1. History of the sterile insect technique

    International Nuclear Information System (INIS)

    Klassen, W.; Curtis, C.F.

    2005-01-01

    During the 1930s and 1940s the idea of releasing insects of pest species to introduce sterility (sterile insect technique or SIT) into wild populations, and thus control them, was independently conceived in three extremely diverse intellectual environments. The key researchers were A. S. Serebrovskii at Moscow State University, F. L. Vanderplank at a tsetse field research station in rural Tanganyika (now Tanzania), and E. F. Knipling of the United States Department of Agriculture. Serebrovskii's work on chromosomal translocations for pest population suppression could not succeed in the catastrophic conditions in the USSR during World War II, after which he died. Vanderplank used hybrid sterility to suppress a tsetse population in a large field experiment, but lacked the resources to develop this method further. Knipling and his team exploited H. J. Muller's discovery that ionizing radiation can induce dominant lethal mutations, and after World War II this approach was applied on an area-wide basis to eradicate the New World screwworm Cochliomyia hominivorax (Coquerel) in the USA, Mexico, and Central America. Since then very effective programmes integrating the SIT have been mounted against tropical fruit flies, some species of tsetse flies Glossina spp., the pink bollworm Pectinophora gossypiella (Saunders), and the codling moth Cydia pomonella (L.). In non-isolated onion fields in the Netherlands, the onion maggot Delia antiqua (Meigen) has since 1981 been suppressed by the SIT. In the 1970s there was much research conducted on mosquito SIT, which then went into 'eclipse', but now appears to be reviving. Development of the SIT for use against the boll weevil Anthonomus grandis grandis Boheman and the gypsy moth Lymantria dispar (L.) has ended, but it is in progress for two sweetpotato weevil species, Cylas formicarius (F.) and Euscepes postfasciatus (Fairmaire), the false codling moth Cryptophlebia leucotreta (Meyrick), the carob moth Ectomyelois ceratoniae

  2. 9. School of radiation sterilization and hygienization - Lectures

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9 School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  3. Assessing genetic variability in male sterile and low fertile citrus ...

    African Journals Online (AJOL)

    Understanding phylogenetic relationships and genetic diversity in citrus are important in clarifying genetic relationships, characterizing germplasm and the registration of new cultivars. In this study, the genetic diversity of 28 accessions of citrus including male sterile, sterile, low fertile and fertile cultivars were investigated ...

  4. Assessment of Non-Sterile Pharmaceutical Compounding Practices ...

    African Journals Online (AJOL)

    A descriptive cross-sectional survey was conducted to assess the practices of non-sterile pharmaceutical compounding in selected 42 community and 3 hospital pharmacies in Addis Ababa, Ethiopia from 01 April, 2016 to 15 May, 2016. The study revealed that the most commonly prescribed and compounded non-sterile ...

  5. Tracking the expression of photosensitive genic male sterility genes ...

    African Journals Online (AJOL)

    Photoperiod sensitive genic male sterile rice lines contain genes that induce complete sterility in high temperature and long day light length period, and revert to fertility in optimum low temperature and short day light length period. These lines are good candidates for hybrid rice seed production. The main challenge limiting ...

  6. An alternative safer and cost effective surface sterilization method for ...

    African Journals Online (AJOL)

    Regardless of its serious health effect, mercury chloride is frequently utilized for surface sterilization to mitigate microbial contamination in sugarcane tissue culture. The current study aimed at finding an alternative safer and cost effective sterilization method to substitute mercury chloride. In the study, sugarcane shoot tip ...

  7. Effect of sterilization on mineralization of straw and black carbon

    DEFF Research Database (Denmark)

    Bobul'ská, Lenka; Bruun, Sander; Fazekašová, Danica

    2013-01-01

    The study was aimed at investigating the role of microorganisms in the degradation of BC (black carbon). CO evolution was measured under sterilized and non-sterilized soil using BC and straw amendments. Black carbon and straw were produced from homogenously C labelled roots of barley (Hordeum vul...... abiotic source must also be present perhaps abiotic mineralization of labile BC components....

  8. 9. School of radiation sterilization and hygienization - Presentations

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9. School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  9. The context and limitations of female sterilization services in Pakistan.

    Science.gov (United States)

    Khan, Adnan Ahmad; Khan, Ayesha; Abbas, Khadija; Tirmizi, Syed Farhan Ali; ul Islam, Zia

    2013-04-01

    Female sterilization has long been the most popular method of family planning (FP) in Pakistan, and yet most public health experts feel it contributes little to controlling family size or to population welfare. We used Pakistan Demographic Health Survey (PDHS) data to understand the role female sterilization plays in the overall context of FP in Pakistan. We performed a secondary analysis of data from the PDHS 1990-1 and 2006-7 to study factors that lead to sterilization and trends in the use of the procedure. In addition, census data were multiplied by proportions from PDHS data to estimate the number of women availing sterilization services. Around 1.9 million women in Pakistan are currently sterilized--up from 0.55 million in 1990-1, and around 173,867 undergo the procedure, annually. Women usually receive sterilization after 30 years of age (mean = 39) and after six children. The probability of sterilization increases with age, family size, and urban residence, and is unaffected by poverty, province of residence, or the woman or her husband's education. Most sterilizationis conducted in public sector facilities. Sterilization in Pakistan may be common, but occurs too late to have any significant effect on family size or benefit public health. Future avenues to make this option more useful to women and society would be to improve the repertoire and access and quality of FP services that are available, and to address governance issues that limit the performance and utility of government facilities.

  10. 42 CFR 50.207 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207...

  11. Hysteroscopic tubal sterilization: a systematic review of the Essure system

    DEFF Research Database (Denmark)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika

    2010-01-01

    sterilization, but more information on the total cost is needed. CONCLUSION(S): The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published...... by Elsevier Inc. All rights reserved....

  12. Comparison of Sterile and Clean Dressing Techniques in Post ...

    African Journals Online (AJOL)

    Comparison of Sterile and Clean Dressing Techniques in Post-operative Surgical Wound Infection in a Chinese Healthcare Facility. ... of sterile and clean dressing techniques on wound management in a Chinese hospital, and to compare their impact on wound healing and the cost of the dressing materials with respect to ...

  13. Female sterilization by tubal ligation at caesarean section in Makurdi ...

    African Journals Online (AJOL)

    Background: Female sterilization is an important tool in reducing unplanned pregnancy and maternal mortality in our environment. The aim of this study was to determine the incidence, sociodemographic characteristics, technique, effectiveness and complications associated with female sterilization by bilateral tubal ligation ...

  14. Puzzles in modern biology. I. Male sterility, failure reveals design.

    Science.gov (United States)

    Frank, Steven A

    2016-01-01

    Many human males produce dysfunctional sperm. Various plants frequently abort pollen. Hybrid matings often produce sterile males. Widespread male sterility is puzzling. Natural selection prunes reproductive failure. Puzzling failure implies something that we do not understand about how organisms are designed. Solving the puzzle reveals the hidden processes of design.

  15. Thermalisation of light sterile neutrinos in the early universe

    DEFF Research Database (Denmark)

    Hannestad, Steen; Tamborra, Irene; Tram, Thomas

    2012-01-01

    on the current cosmological data have been derived using simplified assumptions about thermalisation of the sterile neutrino at the Big Bang Nucleosynthesis (BBN) epoch. These assumptions are not necessarily justified and here we solve the full quantum kinetic equations in the (1 active + 1 sterile) scenario...

  16. Surface sterilization method for reducing microbial contamination of ...

    African Journals Online (AJOL)

    An effective disinfection method for strawberry (Fragaria x ananassa Duch.) cv. Senga Sengana micropropagation using runner tips and nodal segments as explants was developed. The explants were surface sterilized with different sterilants for different durations. The present studies on the effect of different regimes of ...

  17. 21 CFR 800.10 - Contact lens solutions; sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  18. Sterilization by Minilaparotomy in South-Eastern Nigeria | Nwogu ...

    African Journals Online (AJOL)

    The study aimed to assess the trend in acceptance and characteristics of acceptors of female sterilization between January 1999 and December 2006 at the University of Nigeria Teaching Hospital, Enugu, South-Eastern Nigeria. There were a total of 20,485 new clients, with 212 (1.0%) accepting sterilization between ...

  19. 7 CFR 305.28 - Kiln sterilization treatment schedule.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Kiln sterilization treatment schedule. 305.28 Section 305.28 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH... sterilization treatment schedule. T404-b-4 Dry bulb temperature( °F) Wet bulb depression( °F) Percent...

  20. Sterilization of the Mentally Ill and the Mentally Retarded.

    Science.gov (United States)

    National Association of State Mental Health Program Directors, Washington, DC.

    Reported were the results of a survey on the sterilization of the mentally ill and the mentally retarded. Thirty-three states responded to the survey. It was found that 17 states have a sterilization statute, but the existence of the statute was explained not to mean that the procedure was used. Sixteen states responded that they did not have a…

  1. An alternative safer and cost effective surface sterilization method for ...

    African Journals Online (AJOL)

    user

    2013-10-30

    Oct 30, 2013 ... Regardless of its serious health effect, mercury chloride is frequently utilized for surface sterilization to mitigate microbial contamination in sugarcane tissue culture. The current study aimed at finding an alternative safer and cost effective sterilization method to substitute mercury chloride. In the study,.

  2. Efficacy in Microbial Sterilization of Pulsed Magnetic Field Treatment

    Science.gov (United States)

    Sterilization effects of the pulsed magnetic field with a maximum intensity of 11.37 Tesla were investigated on Escherichia coli AS 1.129, Staphylococcus aureus AS 1.89, Saccharomyces cerevisiae ATTC 7552 and Bacillus subtilis AS 1.921. The well-regulated fluctuations of sterilization effects with m...

  3. Radiation effects on polypropylene for sterilization.

    Science.gov (United States)

    Khang, G; Lee, H B; Park, J B

    1996-01-01

    In order to improve the resistance of gamma-radiation sterilization of polypropylene (PP), the formulations of the additives such as antioxidants, crosslinking agent, and trans-stilbene oxide (StO) have been carried out. The irradiated PP and ethylene-propylene copolymer samples with control and additives were characterized by mechanical tester, colorimetry, and Fourier transform infrared spectroscopy with total attenuated reflectance mode (FTIR-ATR). Crosslinking agent and StO formulated PP showed remarkable radiation resistance and minimum discoloration. Also, radiation resistance of ethylene-propylene copolymers with 3% of ethylene contents was better than that of PP homopolymers in the case of no additives. The proposed mechanisms of radiation stabilization with additives are also discussed.

  4. Sterile neutrinos and B–L symmetry

    Directory of Open Access Journals (Sweden)

    Pavel Fileviez Pérez

    2018-02-01

    Full Text Available We revisit the relation between the neutrino masses and the spontaneous breaking of the B–L gauge symmetry. We discuss the main scenarios for Dirac and Majorana neutrinos and point out two simple mechanisms for neutrino masses. In this context the neutrino masses can be generated either at tree level or at quantum level and one predicts the existence of very light sterile neutrinos with masses below the eV scale. The predictions for lepton number violating processes such as μ→e and μ→eγ are discussed in detail. The impact from the cosmological constraints on the effective number of relativistic degree of freedom is investigated.

  5. [The psychosocial background of sterile patients].

    Science.gov (United States)

    Pusch, H H; Urdl, W; Walcher, W

    1989-01-01

    The psychosocial background of 300 childless couples from the Infertility Clinic of the Department of Gynecology and Obstetrics, University of Graz, was evaluated by means of a questionnaire and statistical analysis of data from their files. Points of special interest were problems such as interactions of the couple, motivations for the desire of children, psychosomatics, andrological investigation within the gynecological department, sexual habits and motivation and compliance concerning investigations and treatment. 72% of the questionnaires were returned. 50% of the sterile couples preferred to attend the infertility clinic together. 26% felt restrictions in their sexual behaviour due to the unrealized desire of children, 48% expected improvements in their partnership if they could have children. Compliance of male partners concerning the regular intake of prescribed medicaments was 83%, 63% accepted to stop smoking in cases of pathospermia.

  6. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  7. Heavy Sterile Neutrino in Dark Matter Searches

    Directory of Open Access Journals (Sweden)

    Paraskevi C. Divari

    2018-01-01

    Full Text Available Sterile neutrinos are possible dark matter candidates. We examine here possible detection mechanisms, assuming that the neutrino has a mass of about 50 keV and couples to the ordinary neutrino. Even though this neutrino is quite heavy, it is nonrelativistic with a maximum kinetic energy of 0.1 eV. Thus new experimental techniques are required for its detection. We estimate the expected event rate in the following cases: (i measuring electron recoil in the case of materials with very low electron binding; (ii low temperature crystal bolometers; (iii spin induced atomic excitations at very low temperatures, leading to a characteristic photon spectrum; (iv observation of resonances in antineutrino absorption by a nucleus undergoing electron capture; (v neutrino induced electron events beyond the end point energy of beta decaying systems, for example, in the tritium decay studied by KATRIN.

  8. Radiation treatment for sterilization of packaging materials

    International Nuclear Information System (INIS)

    Haji-Saeid, Mohammad; Sampa, Maria Helena O.; Chmielewski, Andrzej G.

    2007-01-01

    Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology

  9. Radiation sterilized bone response to dynamic loading

    Energy Technology Data Exchange (ETDEWEB)

    Mardas, Marcin, E-mail: marcin.mardas@skpp.edu.pl [Department of Oncology, Poznan University of Medical Sciences, ul. Szamarzewskiego 82/84, 60-569 Poznan (Poland); Kubisz, Leszek [Department of Biophysics, Poznan University of Medical Sciences, ul. Fredry 10, 61-701 Poznan (Poland); Biskupski, Piotr; Mielcarek, Slawomir [Department of Physics, Adam Mickiewicz University, ul. Umultowska 85, 61-614 Poznan (Poland); Stelmach-Mardas, Marta [Department of Bromatology, Poznan University of Medical Sciences, ul. Marcelinska 420, 60-354 Poznan (Poland); Kaluska, Iwona [Centre for Radiation Research and Technology, Institute of Nuclear Chemistry and Technology, ul. Dorodna 16, 03-195 Warsaw (Poland)

    2012-08-01

    Allogeneic bone grafts are used on a large scale in surgeries. To avoid the risk of infectious diseases, allografts should be radiation-sterilized. So far, no international consensus has been achieved regarding the optimal radiation dose. Many authors suggest that bone sterilization deteriorates bone mechanical properties. However, no data on the influence of ionizing radiation on bone dynamic mechanical properties are available. Bovine femurs from 2-year old animal were machine cut and irradiated with the doses 10, 15, 25, 35, 45 and 50 kGy. Dynamic mechanical analysis was performed at 1-10 Hz at the temperature range of 0-350 Degree-Sign C in 3-point bending configuration. No statistically significant differences in storage modulus were observed. However, there were significant decreased values of loss modulus between the samples irradiated with doses of 10 ({down_arrow}14.3%), 15, 45 and 50 kGy ({down_arrow}33.2%) and controls. It was stated that increased irradiation dose decreases the temperature where collagen denaturation process starts and increases the temperature where the collagen denaturation process finishes. It was shown that activation energy of denaturation process is significantly higher for the samples irradiated with the dose of 50 kGy (615 kJ/mol) in comparison with control samples and irradiation with other doses (100-135 kJ/mol). - Highlights: Black-Right-Pointing-Pointer We examine changes in the storage modulus and loss modulus of samples irradiated with doses of 10-50 kGy. Black-Right-Pointing-Pointer We examine changes in the denaturation temperature of samples irradiated with doses of 10-50 kGy. Black-Right-Pointing-Pointer We examine changes in the activation energy of denaturation process of samples irradiated with doses of 10-50 kGy.

  10. Mechanisms of urinary tract sterility maintenance

    Directory of Open Access Journals (Sweden)

    Emilia Okrągła

    2014-06-01

    Full Text Available Physiologically, urine and the urinary tract are maintained sterile because of physical and chemical properties of urine and the innate immune system’s action. The urinary tract is constantly exposed to the invasion of microorganisms from the exterior environment, also because of the anatomical placement of the urethra, in the vicinity of the rectum. Particularly vulnerable to urinary tract infections (UTI are women (an additional risk factor is pregnancy, but also the elderly and children. The main pathogens causing UTI are bacteria; in 70-95% of cases it is the bacterium Escherichia coli. Infections caused by viruses and fungi are less common and are associated with decreased immunity, pharmacotherapy, or some diseases. Bacteria have evolved a number of factors that facilitate the colonization of the urinary tract: the cover and cell membrane antigens O and K1, lipopolysaccharide (LPS, fimbriae, pile and cilia. On the other hand, the human organism has evolved mechanisms to hinder colonization of the urinary tract: mechanisms arising from the anatomical structure of the urinary tract, the physicochemical properties of the urine and the activity of the innate immune system, also known as non-specific, which isolates and destroys pathogens using immunological processes, and the mechanisms for release of antimicrobial substances such as Tamm-Horsfall protein, mucopolysaccharides, immunoglobulins IgA and IgG, lactoferrin, lipocalin, neutrophils, cytokines and antimicrobial peptides. This review aims to analyze the state of knowledge on the mechanisms to maintain the sterility of the urinary tract used by the human organism and bacterial virulence factors to facilitate the colonization of the urinary tract.

  11. Post-sterilization autonomy among young mothers in South India.

    Science.gov (United States)

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  12. Color stability of shade guides after autoclave sterilization.

    Science.gov (United States)

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  13. Development of ozone sterilization system based microcontroller for E. Coli bacteria sterilization

    Science.gov (United States)

    Eko Fahrudin, Arfan; Endarko; Vijai Nasrulloh, Amar; Sari, Nurma

    2017-05-01

    It has been created microcontroller-based ozone sterilization system which is used for E. Coli bacteria sterilization. The created system consists of a neon sign transformer, corona electrode, ozone gas chamber container and ozone gas metering systems. Neon sign transformer and corona electrode are then assembled into an ozone generator that works on the principle of corona discharge. The use of ozone generators is controlled by microcontroller system. Ozone gas is produced by ozone generators which housed in a chamber and equipped by ozone gas indicator. The results of ozone gas effect testing in E. Coli with varied exposure of 15, 30 and 45 minutes showed the decrease number of E. Coli colonies of tested bacteria samples compared to the control sample without ozone gas exposure.

  14. Metody urgentního mapování v krizových situacích s využitím komunitních a participativních nástrojů GIS

    Czech Academy of Sciences Publication Activity Database

    Trojan, Jakub

    2015-01-01

    Roč. 2, č. 2 (2015), s. 1-6 ISSN 1804-1795 Institutional support: RVO:68145535 Keywords : crisis mapping * participative GIS * geoinformatics * crisis management * Ushahidi Subject RIV: DE - Earth Magnetism, Geodesy, Geography http://trilobit.fai.utb.cz/metody-urgentniho-mapovani-v-krizovych-situacich-s-vyuzitim-komunitnich-a-participativnich-nastroju-gis

  15. Impact of moth suppression/eradication programmes using the sterile insect technique or inherited sterility

    International Nuclear Information System (INIS)

    Bloem, K.A.; Bloem, S.; Carpenter, J.E.

    2005-01-01

    Numerous lepidopteran species have been investigated as candidates for control using the sterile insect technique (SIT) or inherited sterility (IS). However to date only two programmes are operational - the pink bollworm containment programme in the San Joaquin Valley, California, USA, and the codling moth suppression programme in British Columbia, Canada. Both of these programmes have been highly successful in controlling the pest populations, reducing insecticide use, and improving interactions between growers and the general public. However, other benefits, including the positive economic impacts of these programmes, have not been fully quantified. Methods to reduce the cost of lepidopteran programmes might include combining the SIT/IS with other pest control tactics such as mating disruption or the release of natural enemies, the development of genetic sexing strains, or the application of molecular technologies to develop genetic markers and genetic sterility. In future the greatest potential for impact of lepidopteran SIT/IS programmes may be in combating key invasive threats such as the eradication of an outbreak of the painted apple moth in New Zealand. (author)

  16. Gamma ray induced male sterility mutant in lentil

    International Nuclear Information System (INIS)

    Srivastava, A.; Yadav, A.K.

    2001-01-01

    Full text: Male sterility refers to the failure of pollen grains to bring about effective fertilization, either due to structural default or physiological disfunctioning and has special significance in hybridization programmes. Male steriles have been produced in a number of crop plants like red gram, pigeon pea, mung bean, khesari and lentil. A completely male sterile mutant was isolated in Lens culinaris Medik, after seed treatment with 100 Gy dose of gamma rays. The male sterile mutant showed 100% pollen sterility but was morphologically more vigorous than the parent plants. It showed more branches and its leaves were bigger, more oblong and dark green. The number of flowers borne by the mutant was significantly higher than any other plant of the treatment. The size of the flowers was also increased but the anthers were smaller in size. Pollen grains were few in number, round in shape but empty and did not take up any stain, indicating that normal microsporogenesis had not taken place. This male sterile mutant was used as the female parent and pollinated with pollen of a parent. Four pods with one seed in each were formed indicating that the mutant was female fertile. The seeds were smaller than those of the parent variety and also dark coloured. The mutant showed increased vigour and flower number as compared to parental plants. Lentil is an important pulse crop and induction of variability in its germplasm is necessary for its improvement. Male steriles can be used conveniently in lentil hybridization programmes. (author)

  17. A research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang

    2010-01-01

    Radiation sterilization is widely applied in food processing, Pharmaceutical Manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. The output value of radiation sterilization industry reached 0.1% of the GDP in some advanced countries (America and Japan...), under this standard, its output value in Sichuan province would be RMB1.2 hundred million, but now our capacity and scale of this industry is less than RMB40million.Research shows: there are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the 'bottleneck' restrictions of capacity and Inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity for radiation sterilization, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  18. Ethylene oxide sterilization: how hospitals can adapt to the changes.

    Science.gov (United States)

    1994-12-01

    Ethylene oxide (EtO) gas sterilizers have been used by hospitals for over 40 years to sterilize surgical equipment and supplies that are heat sensitive or that cannot tolerate excessive moisture. However, in recent decades, EtO has been recognized as a potential mutagenic, reproductive, neurologic, and fire and explosion hazard to workers, and one agency has reportedly voted to classify EtO as carcinogenic to humans. Strict regulations concerning EtO exposure have been imposed by the Occupational Safety and Health Administration (OSHA), and the use of EtO, along with other toxic pollutants, is also being monitored by the Environmental Protection Agency (EPA) under the Clean Air Act. In addition, the use of chlorofluorocarbons (CFCs) as EtO diluents has focused attention on the EtO-CFC mixtures used in many sterilizers because CFCs have been linked to destruction of the ozone layer. Concerns about restrictive regulations related to these issues have prompted many hospitals to examine their use of EtO sterilization and propagated the misinformation that EtO sterilization is being phased out. In this article, we address some commonly asked questions regarding the use and regulation of EtO mixtures, as well as alternative sterilization agents and methods; provide two case studies illustrating how hospitals can evaluate various sterilization options; and summarize our conclusions and recommendations for hospitals facing decisions about sterilization techniques. For related topics, also see our Evaluation Update on endoscope reprocessors and our Hazard Report on improperly connected EtO-CFC cylinders to EtO sterilizers in this issue.

  19. Geographic Variation in Characteristics of Postpartum Women Using Female Sterilization.

    Science.gov (United States)

    White, Kari; Potter, Joseph E; Zite, Nikki

    2015-01-01

    Southern states have higher rates of female sterilization compared with other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women's contraceptive method use between 2006 and 2009. We categorized states according to geographic region: South, Midwest/West, and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. The percentage of postpartum women using sterilization ranged from 5.0% to 9.9% in the Northeast, 8.9% to 10.6% in the Midwest/West, and 11.6% to 22.4% in the South. Women in nearly all subgroups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no differences in the prevalence of sterilization for Blacks compared with Whites in the Northeast (0.76; 95% CI, 0.55-1.06), Midwest/West (0.91; 95% CI, 0.80-1.04), and South (0.96; 95% CI, 0.85-1.07). Women with Medicaid-paid deliveries (vs. private insurance) had a higher prevalence of sterilization in all regions (p sterilization at disproportionately higher rates compared with other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  20. Radio-sterilization and processing of frozen human skin

    International Nuclear Information System (INIS)

    Zarate S, Herman; Aguirre H, Paulina; Silva R, Samy; Hitschfeld G, Mario

    2006-01-01

    The Laboratory of Radio-sterilized Biological Tissues Processing (LPTR) belonging to the Chilean Commission of Nuclear Energy and the International Atomic Energy Agency have played a paramount role in our country, concerning the biological tissue processing, which can be radio-sterilized as human skin, pig skin, amniotic membrane, human bone and bovine bone. The frozen radio.-sterilized human skin processing began in 2001, by means of putting into practice the knowledge acquired in training courses through the IAEA and the experience transferred by experts who visited our laboratory. The human skin processing of dead donor can be divided into 6 stages: a) Profuse washing with physiological sterilized serum in to remove the microorganisms, chemical and pharmacological compounds; b) immersion in glycerol solution at 10% to better keep the stored tissues; c) packing, to avoid post manipulation of the sterilized tissue; d) microbiological controls which allow and guarantee a sterility assurance level of 10 6 ; e) radio-sterilization, technique that consists of exposing the grafts to electromagnetic gamma waves which eliminate the microorganisms of the tissue, f) and finally, dispatching and liberation of the frozen sterilized human skin for its clinical use in different centers that take care of burned people. The LPTR receives feedback from surgeons who have used these tissues in order to improve the processing stages based in an integral quality system ISO 9001.2000. The State Health System in our country counts on limited and scarce resources to implement synthetic substitutes that is why It is considered necessary to spread the use of these noble tissues which have sterility assurance and they are processed at low price

  1. Sterility and meeting competitiveness of medfly, Ceratitis Capitata (Wiedemann)

    International Nuclear Information System (INIS)

    Taein-Tun; Molly-Maung-Maung

    2001-01-01

    The basic methodology in the determination of sterilising dosage in male med flies and mating competitiveness with the normal males was carried out in the laboratory. Application of the Sterile Insect Technique (S.I.T.) by three irradiation dosages on Seib-6096 pupae results in sterility when dosage increased. A lower mating competitiveness was observed with the increase in sterility value. This value was determined from the corrected egg hatch percent. The resulting data showed that irradiation dosage of γ 10.0 Krad gave a good advantage to suppress the population in the next generation. The method suggested a good application in the control and eradication of fruit flies. (author)

  2. Sterile neutrinos as the origin of dark and baryonic matter.

    Science.gov (United States)

    Canetti, Laurent; Drewes, Marco; Shaposhnikov, Mikhail

    2013-02-08

    We demonstrate for the first time that three sterile neutrinos alone can simultaneously explain neutrino oscillations, the observed dark matter, and the baryon asymmetry of the Universe without new physics above the Fermi scale. The key new point of our analysis is leptogenesis after sphaleron freeze-out, which leads to resonant dark matter production, evading thus the constraints on sterile neutrino dark matter from structure formation and x-ray searches. We identify the range of sterile neutrino properties that is consistent with all known constraints. We find a domain of parameters where the new particles can be found with present day experimental techniques, using upgrades to existing experimental facilities.

  3. The processing technology of bread crumbs sterilization by irradiation

    International Nuclear Information System (INIS)

    Zhu Jiating; Li Zhengkui; Zhao Yongfu; Zhang Weidong; Jin Jie; Wu Lei; Wang Xinghai

    2003-01-01

    The processing technology of bread crumbs sterilization by irradiation was studied. The results demonstrated that dose heterogeneity had osculatory connection with pile height and turning, sterilization effect had positive correlation with the irradiation dose and negative correlation with colour. Compared with the CK, the content of crud protein, fat, carbohydrate, microelement and amino acid in irradiated bread crumbs had no obvious change. It is recommended that the range of best sterilization dose be 6-10 kGy and the shelf time of bread crumbs be extended to one year

  4. Is parotid saliva sterile on entry to the oral cavity?

    DEFF Research Database (Denmark)

    Schrøder, Stine A; Bardow, Allan; Eickhardt-Dalbøge, Steffen

    2017-01-01

    CONCLUSION: The present study indicates that parotid saliva is sterile on entry to the oral cavity. OBJECTIVES: The objective was to investigate if parotid saliva is sterile on entry to the oral cavity and, thus, prior to contamination by oral bacteria. METHOD: Forty healthy volunteers were...... there were no cultivable bacteria, whereas bacteria were cultivated in all positive control samples. In eight of 10 PCR samples no bacterial DNA was detected. The most frequent bacteria in the remaining non-sterile parotid saliva samples and positive control samples were non-haemolytical streptococci...

  5. Recurrent sterile abscesses following aluminium adjuvant-containing vaccines.

    Science.gov (United States)

    Klein, Nicola P; Edwards, Kathryn M; Sparks, Robert C; Dekker, Cornelia L

    2009-01-01

    Abscess formation following immunisation is a previously reported complication, generally associated with microbial contamination of the vaccine. Less commonly, such abscesses have been sterile. Here we describe two children evaluated in the Center for Disease Control and Prevention (CDC)-funded Clinical Immunization Safety Assessment (CISA) network who developed recurrent sterile abscesses after administration of vaccines containing aluminium adjuvant, either individually or in combination. Although the abscesses healed without sequelae, these occurrences support an association between receipt of aluminium adjuvant and sterile abscesses in susceptible patients. For patients with similar symptoms, clinicians may wish to choose a vaccine formulation containing the least amount of aluminium adjuvant.

  6. Sterilization of experimental animal feeds with high energy electron beam

    International Nuclear Information System (INIS)

    Takekawa, Tetsuya; Shakudo, Taketomi; Furuta, Masakazu; Tada, Mikiro

    2005-01-01

    Penetration range and depth-dose distribution of 10 MeV electrons within commercial packages of experimental animal feeds were examined with a high power electron accelerator for verification of the application of high energy electron beam irradiation to sterilize experimental animal feeds. Optimum packaging sizes were proposed based on the experimental results. The change of the vitamins and the efficacy of the sterilization by the irradiation were also studied. It is confirmed that the sterilization of experimental animal feeds by 10 MeV electron beam has been completely practical. (author)

  7. The search for sterile neutrinos with SOX-Borexino

    Energy Technology Data Exchange (ETDEWEB)

    Altenmüller, K., E-mail: konrad.altenmueller@ph.tum.de; Agostini, M.; Appel, S. [Technische Universität München, Physik-Department and Excellence Cluster Universe (Germany); Bellini, G. [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Benziger, J. [Princeton University, Chemical Engineering Department (United States); Berton, N. [Centre de Saclay, IRFU, Commissariat a l’Energie Atomique et aux Energies Alternatives (France); Bick, D. [Universität Hamburg, Institut für Experimentalphysik (Germany); Bonfini, G. [INFN Laboratori Nazionali del Gran Sasso (Italy); Bravo, D. [Virginia Polytechnic Institute and State University, Physics Department (United States); Caccianiga, B. [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Calaprice, F. [Princeton University, Physics Department (United States); Caminata, A. [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Cavalcante, P. [INFN Laboratori Nazionali del Gran Sasso (Italy); Chepurnov, A. [Moscow State University Skobeltsyn Institute of Nuclear Physics (Russian Federation); Cribier, M. [Centre de Saclay, IRFU, Commissariat a l’Energie Atomique et aux Energies Alternatives (France); D’Angelo, D. [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Davini, S. [Gran Sasso Science Institute (INFN) (Italy); Derbin, A. [St. Petersburg Nuclear Physics Institute (Russian Federation); Noto, L. di [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Drachnev, I. [Gran Sasso Science Institute (INFN) (Italy); and others

    2016-12-15

    The aim of the SOX-Borexino project is to verify or falsify the existence of eV-scale sterile neutrinos. The existence of sterile neutrinos is suspected because of several anomalies, which were observed in previous experiments. A ~3.7 PBq electron antineutrino source made of {sup 144}Ce will be installed below the Borexino detector at LNGS, Italy, to search for short-baseline oscillations of active-to-sterile neutrinos within the detector volume. Source delivery and beginning of data acquisition is planned for end of 2016, preliminary results are expected already in 2017.

  8. Committee Opinion No. 695: Sterilization of Women: Ethical Issues and Considerations.

    Science.gov (United States)

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  9. Committee Opinion No 695 Summary: Sterilization of Women: Ethical Issues and Considerations.

    Science.gov (United States)

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  10. [Sterilization by ovariotexy, a reversible technic].

    Science.gov (United States)

    Wood, C; Leeton, J

    1970-01-01

    6 women were sterilized by ovariotexy, enclosing the ovaries in silastic bags within the peritoneum. The patients ranged in age from 23-33 years, in parity from 1-5, with indications such as hemophiliac and anencephalic children, mental illness, nephrotic syndrome, multiple contraceptive failures, and divorce. The surgical technique involved section of the ovarian ligament and incision of the peritonium from the tube to the ovary. The ovary was fastened in a Silastic bag with Silastic adhesive type A (Dow Corning Corporation), and held in place by suturing it to the ovarian pedicle. The bag and ovary were placed in a pocket created by dissecting the external half of the posterior fold of the broad ligament as far as possible from the tube. The peritoneum was closed and sutured to the mesosalpinx above the round ligament with atraumatic chromic catgut 000. There were no postoperative complications up to 12 days, no pregnancies and no gynecologic findings during follow-up of 6-18 months. 1 patient tested still had tubal patency on insufflation 6 days after the operation. 2 temperature curves recorded were biphasic. It is too soon to learn whether this method will be reversible, but use of silastic should prevent adhesions while providing another mechanical barrier between ovum and sperm.

  11. Infection Risk in Sterile Operative Procedures.

    Science.gov (United States)

    Tacconelli, Evelina; Müller, Niklas F; Lemmen, Sebastian; Mutters, Nico T; Hagel, Stefan; Meyer, Elisabeth

    2016-04-22

    The main objective of hospital hygiene and infection prevention is to protect patients from preventable nosocomial infections. It was recently stated that the proper goal should be for zero infection rates in sterile surgical procedures. In this article, we attempt to determine whether this demand is supported by the available literature. We systematically searched the Medline and EMBASE databases for studies published in the last 10 years on the efficacy of infection control measures and carried out a meta-analysis according to the PRISMA tool. We used the following search terms: "aseptic surgery," "intervention," "surgical site infection," "nosocomial infection," "intervention," and "prevention." 2277 articles were retrieved, of which 204 were acquired in full text and analyzed. The quantitative analysis included 7 prospective cohort studies on the reduction of nosocomial infection rates after aseptic surgery. The measures used included training sessions, antibiotic prophylaxis, and operative-site disinfection and cleaning techniques. These interventions succeeded in reducing postoperative wound infections (relative risk (RR] 0.99 [0.98; 1.00]). Subgroup analyses on antibiotic prophylaxis (RR 0.99 [0.98; 1.01]) and noncontrolled trials (RR 0.97 [0.92; 1.02]) revealed small, insignificant effects. A multimodal approach with the participation of specialists from various disciplines can further reduce the rate of postoperative infection. A reduction to zero is not realistic and is not supported by available evidence.

  12. Belgian experience with radiation technologies for sterilization

    International Nuclear Information System (INIS)

    Bonet, H.; Dardenne, P.; Herier, A.

    1998-01-01

    Belgium pioneered in non energetic applications of nuclear science. In 1970, the National Institute for Radioisotopes (IRE) was founded on the ground of the experience acquired at the CEN/SCK, for developing nuclear techniques oriented to the well-being of population. In 1978 IRE started operation of 2 γ-irradiation units with a 2.25 million Ci Co 60 , source having a capacity for sterilization of more than 100 m 3 of product per day. this installation is currently operated by Griffith-Mediris (Group Griffith Micro Science) and has accumulated 20 years of experience for irradiation of foodstuffs, medical appliances and pharmaceuticals. In 1986, IRE was producing radioisotopes from accelerators and joined UCL for founding Ion Beam Applications (IBA) company which shortly became the world leader for design and delivery of cyclotrons. More recently, on the basis of French CEA patent, IBA developed the Rhodotron, an e-beam accelerator, with an X-ray option, which is now facing commercial success i area of ionization of food and medical appliances. IRE developed also expertise for the back-end of these activities i.e. final disposal of radioactive sealed source and dismantling of the installations. (author)

  13. The sterile insect technique for controlling populations of Aedes albopictus (Diptera: Culicidae) on Reunion Island: mating vigour of sterilized males.

    Science.gov (United States)

    Oliva, Clelia F; Jacquet, Maxime; Gilles, Jeremie; Lemperiere, Guy; Maquart, Pierre-Olivier; Quilici, Serge; Schooneman, François; Vreysen, Marc J B; Boyer, Sebastien

    2012-01-01

    Reunion Island suffers from high densities of the chikungunya and dengue vector Aedes albopictus. The sterile insect technique (SIT) offers a promising strategy for mosquito-borne diseases prevention and control. For such a strategy to be effective, sterile males need to be competitive enough to fulfil their intended function by reducing wild mosquito populations in natura. We studied the effect of irradiation on sexual maturation and mating success of males, and compared the sexual competitiveness of sterile versus wild males in the presence of wild females in semi-field conditions. For all untreated or sterile males, sexual maturation was completed within 13 to 20 h post-emergence and some males were able to inseminate females when 15 h old. In the absence of competition, untreated and sterile males were able to inseminate the same number of virgin females during 48 h, in small laboratory cages: an average of 93% of females was inseminated no matter the treatment, the age of males, and the sex ratio. Daily mating success of single sterile males followed the same pattern as for untreated ones, although they inseminated significantly fewer females after the ninth day. The competitiveness index of sterile males in semi-field conditions was only 0.14 when they were released at 1-day old, but improved to 0.53 when the release occurred after a 5-day period in laboratory conditions. In SIT simulation experiments, a 5:1 sterile to wild male ratio allowed a two-fold reduction of the wild population's fertility. This suggests that sterile males could be sufficiently competitive to mate with wild females within the framework of an SIT component as part of an AW-IPM programme for suppressing a wild population of Ae. albopictus in Reunion Island. It will be of interest to minimise the pre-release period in controlled conditions to ensure a good competitiveness without increasing mass rearing costs.

  14. Transcriptional regulation of male-sterility in 7B-1 male-sterile tomato mutant.

    Directory of Open Access Journals (Sweden)

    Vahid Omidvar

    Full Text Available The 7B-1 tomato (Solanum lycopersicum L. cv Rutgers is a male-sterile mutant with enhanced tolerance to abiotic stress, which makes it a potential candidate for hybrid seed breeding and stress engineering. To underline the molecular mechanism regulating the male-sterility in 7B-1, transcriptomic profiles of the 7B-1 male-sterile and wild type (WT anthers were studied using mRNA sequencing (RNA-Seq. In total, 768 differentially expressed genes (DEGs were identified, including 132 up-regulated and 636 down-regulated transcripts. Gene ontology (GO enrichment analysis of DEGs suggested a general impact of the 7B-1 mutation on metabolic processes, such as proteolysis and carbohydrate catabolic process. Sixteen candidates with key roles in regulation of anther development were subjected to further analysis using qRT-PCR and in situ hybridization. Cytological studies showed several defects associated with anther development in the 7B-1 mutant, including unsynchronized anther maturation, dysfunctional meiosis, arrested microspores, defect in callose degradation and abnormal tapetum development. TUNEL assay showed a defect in programmed cell death (PCD of tapetal cells in 7B-1 anthers. The present study provides insights into the transcriptome of the 7B-1 mutant. We identified several genes with altered expression level in 7B-1 (including beta-1,3 glucanase, GA2oxs, cystatin, cysteine protease, pectinesterase, TA29, and actin that could potentially regulate anther developmental processes, such as meiosis, tapetum development, and cell-wall formation/degradation.

  15. Metody statystyczne w badaniach dialektologicznych

    OpenAIRE

    Kąś, Józef

    1986-01-01

    Statistical methods are an indispensable instrument for modern dialectological research which concentrates on the 'mutual influence of general language and dialects. Their usefulness is especially visible in phonetic research. The numerical presentation of linguistic phenomena must, however, be combined with differentiation between the official and unofficial character of the research situation during which the linguistic material is collected. Zadanie pt. „Digitalizacja...

  16. Męska depresja – koncepcja, metody pomiaru i związki z zachowaniami samobójczymi

    Directory of Open Access Journals (Sweden)

    Jan Chodkiewicz

    2016-03-01

    Full Text Available W artykule przedstawiono koncepcję atypowych objawów depresji występujących u mężczyzn. Ważnym źródłem tej koncepcji były doświadczenia wyniesione z programu diagnozowania i leczenia depresji wprowadzonego na Gotlandii (Szwecja w latach 80. ubiegłego stulecia. Program, skierowany do lekarzy rodzinnych, zmniejszył liczbę zachowań samobójczych wśród kobiet, ale nie wśród mężczyzn. Przyjęto, że jedną z przyczyn takiego stanu rzeczy może być odmienny obraz depresji u obu płci. Różnice między płciami mogą odpowiadać za to, że depresja u mężczyzn znacznie częściej niż u kobiet pozostaje nierozpoznana i nieleczona, co prowadzi do zwiększenia liczby samobójstw. Wśród dominujących objawów depresji u mężczyzn wyróżniono wzrost impulsywności i zachowań agresywnych, nadużywanie substancji psychoaktywnych (alkohol, narkotyki, nikotyna, podejmowanie zachowań ryzykownych (jazda samochodem pod wpływem alkoholu, przypadkowe kontakty seksualne oraz tłumienie emocji. Jako przyczyna występowania atypowej depresji u mężczyzn najczęściej wymieniane jest rygorystyczne podporządkowywanie się tradycyjnym męskim normom kulturowym. Normy te dotyczą odporności, wytrzymałości, konkurowania, opanowania i tłumienia uczuć oraz konieczności zapewnienia bytu rodzinie. W pracy omówiono najbardziej znane metody badania męskiej depresji – Gotland Male Depression Scale (GMDS Rutza, Male Depression Risk Scale (MDRS-22 Rice’a i współpracowników oraz Masculine Depression Scale (MDS Magovcevic i Addisa – a także przedstawiono wyniki badań prowadzonych z użyciem wspomnianych metod. Artykuł kończą refleksje dotyczące dalszych kierunków badań nad problemem męskiej depresji i opis kontrowersji związanych z omawianą koncepcją.

  17. Possibilities of sterilizing nutrient media used to grow tissue cultures

    International Nuclear Information System (INIS)

    Veber, P.; Leshko, Ya.; Gana, L.; Yankovicheva, T.; Yurmanova, K.

    1976-01-01

    Effects of radiosterilization on the properties of liquid and powdery Eagle's media and on inactivated calf and horse sera are described. It is shown that radiosterilization may be employed to sterilize biological agents required for in vitro cell cultivation. (author)

  18. Postpartum Sterilization Choices Made by HIV-Infected Women

    Directory of Open Access Journals (Sweden)

    Gretchen S. Stuart

    2005-01-01

    Full Text Available Objective. To assess if HIV-infected women made different choices for postpartum sterilization after implementation of the Pediatric AIDS Clinical Trials Group protocol 076 (November 1, 1994 compared to before implementation.

  19. Are there sterile neutrinos at the eV scale?

    Science.gov (United States)

    Kopp, Joachim; Maltoni, Michele; Schwetz, Thomas

    2011-08-26

    New predictions for the antineutrino flux from nuclear reactors suggest that reactor experiments may have measured a deficit in this flux, which can be interpreted in terms of oscillations between the known active neutrinos and new sterile states. We perform a reanalysis of global short-baseline neutrino oscillation data in a framework with one or two sterile neutrinos. While one sterile neutrino is still not sufficient to reconcile the signals suggested by reactor experiments and by the LSND and MiniBooNE experiments with null results from other searches, we find that, with the new reactor flux prediction, the global fit improves considerably when two sterile neutrinos are introduced. © 2011 American Physical Society

  20. Compulsory Sterilization: The Change in India's Population Policy

    Science.gov (United States)

    Gulhati, Kaval

    1977-01-01

    Reviews India's previous stand regarding family planning which favored the notion that economic development would provide the incentive for fertility control. Recent recommendations, however, include raising minimum marriage age for girls and increasing incentives for acceptance of sterilization. (CS)

  1. Steam sterilization costs: a guide for the central service manager.

    Science.gov (United States)

    O'Shaughnessy, K L

    1993-07-01

    The Nassau County Medical Center CS department, East Meadow, New York, was faced with a staff layoff and an increased workload. With some hard thinking and strong staff support, new processes/systems were designed to save time and money. These included outsourcing the sterilization of "easy" trays, instituting a case cart program and developing custom packs. In order to determine where savings could be had, it was first important to examine current costs. By breaking the costs of sterilization processing down into an average cost per load, a formula was developed that helped determine many additional cost comparisons for the department. For example, the cost analysis formula could be used by CS departments to determine the cost-effectiveness of off-site sterilization, to compare using disposable vs. reusable items and to determine costs for EtO sterilization and aeration.

  2. Protozoa and their bacterial prey colonize sterile soil fast

    DEFF Research Database (Denmark)

    Altenburger, Andreas; Ekelund, Flemming; Jacobsen, Carsten Suhr

    2010-01-01

    We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them to the at......We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them...... to the atmosphere for a period of 14 months. Bacteria and flagellates occurred in high numbers after 25 days. Ciliates reached high abundance levels after 137 days, followed by amoebae after 245 days. Numbers of distinguishable protozoan morpho-types increased until 245 days after exposure and declined thereafter...

  3. Influence of reactive oxygen species on the sterilization of microbes

    Science.gov (United States)

    The influence of reactive oxygen species on living cells, including various microbes, is discussed. A sterilization experiment with bacterial endospores reveals that an argoneoxygen plasma jet very effectively kills endospores of Bacillus atrophaeus (ATCC 9372), thereby indicating that oxygen radic...

  4. ( Atp9) gene between cytoplasmic male sterile line and its ...

    African Journals Online (AJOL)

    Administrator

    2011-09-07

    , the atp9 gene in soybeans was cloned from a soybean cytoplasmic male sterile line NJCMS2A and its maintainer line NJCMS2B. Sequence alignment was performed, and protein structures were analyzed and compared ...

  5. Design, Construction and Evaluation of a Dry Solar Sterilizer

    International Nuclear Information System (INIS)

    Hernández Fereira, Arcelio A.

    2017-01-01

    The objective of the work was the search of an alternative for sterilization using solar energy. For such purposes, a dry solar sterilizer of 4276 cm3 capacity was designed, constructed and evaluated. Potential users would be rural medical posts in areas without electricity, health posts in military units under field conditions, and experimental microbiology stations. The evaluation included the determination of the energy efficiency of the sterilizer, the economic evaluation against other variants and the biological safety assessment. The developed equipment reached the sterilization temperature for levels of the direct component of the solar radiation higher than 300 W/m2 in 14 minutes, corresponding to an average heating rate of 13 0C/minute, higher than that of an electric furnace. Its energy efficiency with direct solar radiation of 310.5 W/m2 was 53.79%. The equipment is of easy construction, simple operation and very low cost. (author)

  6. Radiation sterilization of traditional medicine drugs in Vietnam

    International Nuclear Information System (INIS)

    Hang, N.D.; Canh, T.T.; Thuy, T.T.

    1995-01-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author)

  7. Mating competitiveness of sterile male Anopheles coluzzii in large cages.

    Science.gov (United States)

    Maïga, Hamidou; Damiens, David; Niang, Abdoulaye; Sawadogo, Simon P; Fatherhaman, Omnia; Lees, Rosemary S; Roux, Olivier; Dabiré, Roch K; Ouédraogo, Georges A; Tripet, Fréderic; Diabaté, Abdoulaye; Gilles, Jeremie R L

    2014-11-26

    Understanding the factors that account for male mating competitiveness is critical to the development of the sterile insect technique (SIT). Here, the effects of partial sterilization with 90 Gy of radiation on sexual competitiveness of Anopheles coluzzii allowed to mate in different ratios of sterile to untreated males have been assessed. Moreover, competitiveness was compared between males allowed one versus two days of contact with females. Sterile and untreated males four to six days of age were released in large cages (~1.75 sq m) with females of similar age at the following ratios of sterile males: untreated males: untreated virgin females: 100:100:100, 300:100:100, 500:100:100 (three replicates of each) and left for two days. Competitiveness was determined by assessing the egg hatch rate and the insemination rate, determined by dissecting recaptured females. An additional experiment was conducted with a ratio of 500:100:100 and a mating period of either one or two days. Two controls of 0:100:100 (untreated control) and 100:0:100 (sterile control) were used in each experiment. When males and females consort for two days with different ratios, a significant difference in insemination rate was observed between ratio treatments. The competitiveness index (C) of sterile males compared to controls was 0.53. The number of days of exposure to mates significantly increased the insemination rate, as did the increased number of males present in the untreated: sterile male ratio treatments, but the number of days of exposure did not have any effect on the hatch rate. The comparability of the hatch rates between experiments suggest that An. coluzzii mating competitiveness experiments in large cages could be run for one instead of two days, shortening the required length of the experiment. Sterilized males were half as competitive as untreated males, but an effective release ratio of at least five sterile for one untreated male has the potential to impact the fertility of

  8. How self-interactions can reconcile sterile neutrinos with cosmology.

    Science.gov (United States)

    Hannestad, Steen; Hansen, Rasmus Sloth; Tram, Thomas

    2014-01-24

    Short baseline neutrino oscillation experiments have shown hints of the existence of additional sterile neutrinos in the eV mass range. However, such neutrinos seem incompatible with cosmology because they have too large of an impact on cosmic structure formation. Here we show that new interactions in the sterile neutrino sector can prevent their production in the early Universe and reconcile short baseline oscillation experiments with cosmology.

  9. Sterilization of Lung Matrices by Supercritical Carbon Dioxide.

    Science.gov (United States)

    Balestrini, Jenna L; Liu, Angela; Gard, Ashley L; Huie, Janet; Blatt, Kelly M S; Schwan, Jonas; Zhao, Liping; Broekelmann, Tom J; Mecham, Robert P; Wilcox, Elise C; Niklason, Laura E

    2016-03-01

    Lung engineering is a potential alternative to transplantation for patients with end-stage pulmonary failure. Two challenges critical to the successful development of an engineered lung developed from a decellularized scaffold include (i) the suppression of resident infectious bioburden in the lung matrix, and (ii) the ability to sterilize decellularized tissues while preserving the essential biological and mechanical features intact. To date, the majority of lungs are sterilized using high concentrations of peracetic acid (PAA) resulting in extracellular matrix (ECM) depletion. These mechanically altered tissues have little to no storage potential. In this study, we report a sterilizing technique using supercritical carbon dioxide (ScCO2) that can achieve a sterility assurance level 10(-6) in decellularized lung matrix. The effects of ScCO2 treatment on the histological, mechanical, and biochemical properties of the sterile decellularized lung were evaluated and compared with those of freshly decellularized lung matrix and with PAA-treated acellular lung. Exposure of the decellularized tissue to ScCO2 did not significantly alter tissue architecture, ECM content or organization (glycosaminoglycans, elastin, collagen, and laminin), observations of cell engraftment, or mechanical integrity of the tissue. Furthermore, these attributes of lung matrix did not change after 6 months in sterile buffer following sterilization with ScCO2, indicating that ScCO2 produces a matrix that is stable during storage. The current study's results indicate that ScCO2 can be used to sterilize acellular lung tissue while simultaneously preserving key biological components required for the function of the scaffold for regenerative medicine purposes.

  10. Pharmaceutical aerosols. Study of their gamma radiation sterilization

    International Nuclear Information System (INIS)

    Sebert, P.

    1984-10-01

    The gamma radiation sterilization of pharmaceutical aerosols was studied. The following topics were investigated: radiosterilization of nitrogen protoxide used as a propellant; radiosterilization of packaging materials (aluminium containers, plastics valves); radio-sterilization of excipients and active ingredients. Most of the investigated materials proved to be stable to irradiation (2,5 Mrads) from pharmacopoeial aspect. Stability tests of the preparations packaged showed no change in the parameters investigated [fr

  11. Dosimetry intercomparisons in European medical device sterilization plants

    DEFF Research Database (Denmark)

    Miller, A.; Sharpe, P.H.G.

    2000-01-01

    Dosimetry intercomparisons have been carried out involving two-thirds of all European radiation sterilization facilities. Dosimeters for the intercomparisons were supplied by two accredited calibration laboratories. The results show good agreement, and indicate overall dosimetry accuracy of the o......Dosimetry intercomparisons have been carried out involving two-thirds of all European radiation sterilization facilities. Dosimeters for the intercomparisons were supplied by two accredited calibration laboratories. The results show good agreement, and indicate overall dosimetry accuracy...

  12. Gamma radiations an effective way of monoclonal antibodies sterilization

    International Nuclear Information System (INIS)

    Lenay Barrera Barroso, Lenay; Otero Abreu, Isabel; Rodriguez Napoles, Dania; Bulte Ocanna, Dubhe; Caballero, Idania

    2006-01-01

    The sterilization for radiations of pharmaceutical products is an effective, sure and reliable procedure; that it have been proving technically and grateful for different pharmacopoeia. The Monoclonal Antibodies (Acm) produced in the Center of Molecular Immunology (CIM) are products parenteral for the one which results indispensable that they complete the requirements of established sterility. The radio sterilization result the method more recommend for the sterilization of the Acm deep drying, due to the contained first floor of humidity remnant that minimizes the formation of sub-product that they affect their properties. With the objective of proposing a good dose of irradiation for the sterilization, we were carried out a study of the radius sensibility so much of the product like of the polluting of greater frequency of isolation of the clean area of the CIM. The characterization of the radius sensibility of the different micro- organisms was determined by D 10 characteristic of each isolated strains. From the developed studies the Gram-positive rods endospore-forming were the most resistant strains at the deep drying, the radiations and they were of the greater frequency of apparition in the carried out isolations. We could conclude that utilizing a dose of 10 kGy it is possible to eliminate of the pollution more radio resistant, assuring the sterility required in the product, and without inducing effects under desire radiolytic in the same

  13. Effect of fermentation and sterilization on anthocyanins in blueberry.

    Science.gov (United States)

    Nie, Qixing; Feng, Lei; Hu, Jielun; Wang, Sunan; Chen, Haihong; Huang, Xiaojun; Nie, Shaoping; Xiong, Tao; Xie, Mingyong

    2017-03-01

    Blueberry products have various health benefits due to their high content of dietary anthocyanins. The aim of this study was to investigate the impact of fermentation and sterilization on total anthocyanin content, composition and some quality attributes of blueberry puree. The blueberry puree used here was fermented for 40 h at 37 °C by Lactobacillus after sterilization. The method of ultra-performance liquid chromatography-mass spectrometry was optimized for the rapid analysis of anthocyanins. Quality attributes including pH, color, total soluble solids and viscosity were measured. A total of 21 anthocyanins and five anthocyanidins were quantified by ultra-performance liquid chromatography. Fermented blueberry had reduced total anthocyanin content (29%) and levels of individual anthocyanins compared with fresh blueberry. Total anthocyanin content was decreased 46% by sterilization, and different degradation behavior of individual anthocyanin was appeared between fermented and sterilized-fermented blueberry puree. Fermentation and sterilization decreased the total soluble solids and pH and changed color parameters, while minimally influencing viscosity. The loss of total anthocyanin content by fermentation was related to the unstable structure of blueberry anthocyanins. Anthocyanins are sensitive to temperature (>80 °C), and degradation of anthocyanins by sterilization in blueberry should be considered in the fermentation procedure. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  14. A search for sterile neutrinos with the latest cosmological observations

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Lu; Zhang, Jing-Fei [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Zhang, Xin [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Peking University, Center for High Energy Physics, Beijing (China)

    2017-06-15

    We report the result of a search for sterile neutrinos with the latest cosmological observations. Both cases of massless and massive sterile neutrinos are considered in the ΛCDM cosmology. The cosmological observations used in this work include the Planck 2015 temperature and polarization data, the baryon acoustic oscillation data, the Hubble constant direct measurement data, the Planck Sunyaev-Zeldovich cluster counts data, the Planck lensing data, and the cosmic shear data. We find that the current observational data give a hint of the existence of massless sterile neutrino (as dark radiation) at the 1.44σ level, and the consideration of an extra massless sterile neutrino can indeed relieve the tension between observations and improve the cosmological fit. For the case of massive sterile neutrino, the observations give a rather tight upper limit on the mass, which implies that actually a massless sterile neutrino is more favored. Our result is consistent with the recent result of neutrino oscillation experiment done by the Daya Bay and MINOS collaborations, as well as the recent result of cosmic ray experiment done by the IceCube collaboration. (orig.)

  15. Sterilizing elastomeric chains without losing mechanical properties. Is it possible?

    Directory of Open Access Journals (Sweden)

    Matheus Melo Pithon

    2015-06-01

    Full Text Available OBJECTIVE: To investigate the effects of different sterilization/disinfection methods on the mechanical properties of orthodontic elastomeric chains. METHODS: Segments of elastomeric chains with 5 links each were sent for sterilization by cobalt 60 (Co60 (20 KGy gamma ray technology. After the procedure, the elastomeric chains were contaminated with clinical samples of Streptococcus mutans. Subsequently, the elastomeric chains were submitted to sterilization/disinfection tests carried out by means of different methods, forming six study groups, as follows: Group 1 (control - without contamination, Group 2 (70°GL alcohol, Group 3 (autoclave, Group 4 (ultraviolet, Group 5 (peracetic acid and Group 6 (glutaraldehyde. After sterilization/disinfection, the effectiveness of these methods, by Colony forming units per mL (CFU/mL, and the mechanical properties of the material were assessed. Student's t-test was used to assess the number of CFUs while ANOVA and Tukey's test were used to assess elastic strength. RESULTS: Ultraviolet treatment was not completely effective for sterilization. No loss of mechanical properties occurred with the use of the different sterilization methods (p > 0.05. CONCLUSION: Biological control of elastomeric chains does not affect their mechanical properties.

  16. Sterile Neutrino Search in the NOvA Far Detector

    Energy Technology Data Exchange (ETDEWEB)

    Edayath, Sijith [Cochin U.; Aurisano, Adam [Cincinnati U.; Sousa, Alexandre [Cincinnati U.; Davies, Gavin [Indiana U.; Suter, Louise [Fermilab; Yang, Shaokai [Cincinnati U.

    2017-10-03

    The majority of neutrino oscillation experiments have obtained evidence for neutrino oscillations that are compatible with the three-flavor model. Explaining anomalous results from short-baseline experiments, such as LSND and MiniBooNE, in terms of neutrino oscillations requires the existence of sterile neutrinos. The search for sterile neutrino mixing conducted in NOvA uses a long baseline of 810 km between Near Detector (ND) at Fermilab and Far Detector (FD) in Minnesota. The signal for sterile neutrino oscillations is a deficit of neutral-current neutrino interactions at the FD with respect to the ND prediction. In this document, We will present the analysis improvements that we are implementing for future NC sterile neutrino searches with NOvA. These include: improved modelling of our detector response; the inclusion of NC 2p2h interaction modelling; implementing a better energy reconstruction techniques; and including possible oscillation due to sterile neutrinos in the ND . This improvements enable us to do a simultaneous ND-FD shape fit of the NC energy spectrum covering a wider sterile mass range than previous analyses.

  17. Development of atmospheric pressure plasma needle jet for sterilization applications

    Science.gov (United States)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Soon, Chin Fhong; Sahdan, Mohd Zainizan; Lias, Jais; Wibowo, Kusnanto Mukti; Bakar, Ahmad Shuhaimi Abu; Arshad, Mohd Khairuddin Md; Hashim, Uda; Nayan, Nafarizal

    2017-09-01

    Inactivation of bacteria or sterilization has been a major issue in the medical field, especially regarding of human safety, whereby, in a huge scenario fatality can be caused by hazardous bacteria. Often, E-coli as gram-negative bacteria are selected as a key indicator of proper sterilization process as E-coli is tough and dormant bacteria. The technology in sterilization has moved on from chemical, wet and irradiation sterilization to a high promising device such as atmospheric pressure plasma needle jet (APPNJ). It has been reported that atmospheric pressure plasma has provided bundle of advantages over earlier sterilization process. The APPNJ is developed in our lab using high frequency and high voltage neon transformer power supply connected to copper needle and copper sheet electrodes. The gas discharge is Ar gas flowing at 40 L/min through a quartz glass tube. The E-coli bacteria are self-cultured from waste water and then treated with APPNJ. The treatment processes are run into two difference gaps between the plasma orifice and sample with various treatment times. Only 40s is required by direct treatment to achieve 100% killing of E-coli. On the other hand, indirect treatment has inactivated 50% of the E-coli in 40s. In this study, direct and indirect effect of APPNJ to the E-coli can be observed which can be utilized into sterilization of bio-compatible material applications.

  18. Sterilization techniques without heating (ultraviolet ray, radiation and ozone)

    International Nuclear Information System (INIS)

    Ito, Hitoshi

    1991-01-01

    The recent demand of consumers for processed foods is characterized by the intention for health and nature, besides, the demand for low sweetness, salt reduction, no additive and freshness becomes strong. In view of the control of microorganisms in products, all these become the negative factors. Accordingly, in order to overcome them, it is urgently desired to develop new technology or to improve conventional methods. As to heating sterilization, the uniform temperature treatment to the inside of foods is difficult, and it cannot be applied to perishables. The high temperature sterilization above 120degC causes the change in nutrition composition and physical properties. Ultraviolet ray and ozone can be used for the sterilization of food surface and powder and liquid foods. Radiation treatment can be applied to packed foods and frozen foods as well as food surface. The principle and the fields of application of ultraviolet ray sterilization, radiation sterilization and ozone sterilization are reported. In the mechanism of these methods, the action to DNA and oxidation are common. (K.I.)

  19. Sterilization of rotary NiTi instruments within endodontic sponges.

    Science.gov (United States)

    Chan, H W A; Tan, K H; Dashper, S G; Reynolds, E C; Parashos, P

    2015-08-17

    To determine whether the following can be sterilized by autoclaving - endodontic sponges, rotary nickel-titanium (NiTi) instruments within endodontic sponges, and rotary NiTi instruments with rubber stoppers. Sixty-four samples of eight different endodontic sponges (n = 512) were placed into brain heart infusion broth (BHI) for 72 h. An aliquot of this was then spread onto horse blood agar and cultured aerobically and anaerobically to test sterility at purchase. Bacterial suspensions of Enterococcus faecalis, Porphyromonas gingivalis and Geobacillus stearothermophilus in BHI were used to contaminate sterile sponges and rotary NiTi instruments (with and without rubber stoppers) inserted into sponges. The various samples were autoclaved and then cultured aerobically and anaerobically. Success of sterilization was measured qualitatively as no growth. The experiment was repeated with clinically used rotary NiTi instruments (n = 512). All experiments were conducted in quadruplicate. No sponges on purchase had microbial growth when anaerobically cultured but some did when aerobically cultured. All autoclaved sponges and instruments (within or without sponges, and with or without rubber stoppers) were associated with no microbial growth. All nonautoclaved positive control samples showed microbial growth. Autoclaving was effective in the sterilization of sponges and endodontic instruments. Endodontic sponges should be autoclaved before clinical use. For clinical efficiency and cost-effectiveness, rotary NiTi instruments can be sterilized in endodontic sponges without removal of rubber stoppers. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  20. Radiating sterilization of the venom of snake

    International Nuclear Information System (INIS)

    Abiyev, H.A.; Topchiyeva, Sh.A.; Rustamov, V.R.

    2006-01-01

    Full text: Water solutions of venoms are unstable and they lose toxicity in some day. Snake venoms inactivate under action of some physical factors: the UV-irradiation, x-rays beams. The purpose of the present work was sterilization of venom Vipera lebetina obtusa under influence of small dozes γ-radiations. Object of research was integral venom of adult individuals. Transcaucasian viper, and also the water solutions of venom irradiated with small dozes scale of radiation. An irradiation of venom carried out to radioisotope installation 60NI. For experiment tests of dry venom, and also their water solutions have been taken. Water solutions of venom have been subjected -radiation up to dozes 1.35, 2.7, 4.05, 5.4 kGr simultaneously dry venom of vipers was exposed -radiation before absorption of a doze 5.4 kGr. In comparative aspect action scale of radiation on ultra-violet spectra of absorption of venom was studied. Ultra-violet spectra venom have been taken off on device Specord UV-VIS. In 12 months after an irradiation spectra of absorption of venom have been repeatedly taken off. In spectra irradiated dry and solutions of venom new maxima of absorption have been revealed in the field of 285 nm and 800 nm describing change of toxicity. It is shown, that the increase in absorption of a doze of radiation occurs decrease of intensity of strips of absorption reduction of intensity of absorption.It is revealed at 260 and 300 nm testifying to course of biochemical reactions of separate enzymes zootoxins. It is necessary to note, that at comparison of intensity of absorption of control samples of poison with irradiated up to dozes 1.35 kGr it has not been revealed essential changes. The subsequent increase in a doze scale of radiation up to 2.7, 4.05, 5.4 kGr promotes proportional reduction of intensity of the absorption, describing toxicity of snake venom. At repeated (later 12 months) measurement of the irradiated water solutions of venom are not revealed changes in

  1. A genetic male sterile line developed by molecular marker-assisted ...

    African Journals Online (AJOL)

    use

    2011-12-05

    Dec 5, 2011 ... of male sterility, and methods of crossing, backcrossing and selfing were applied to breed the male sterility to male fertile line of Chinese cabbage Y02. The SCAR marker syau-scr04 which linked to the male sterility gene Ms, was applied in the selection of Ms gene. The new male sterile line GMS4 with.

  2. 42 CFR 441.253 - Sterilization of a mentally competent individual aged 21 or older.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization of a mentally competent individual... LIMITS APPLICABLE TO SPECIFIC SERVICES Sterilizations § 441.253 Sterilization of a mentally competent individual aged 21 or older. FFP is available in expenditures for the sterilization of an individual only if...

  3. A genetic male sterile line developed by molecular marker-assisted ...

    African Journals Online (AJOL)

    A multiple allele inherited genetic male sterile line of Chinese cabbage 06s x 110 was used as the source of male sterility, and methods of crossing, backcrossing and selfing were applied to breed the male sterility to male fertile line of Chinese cabbage Y02. The SCAR marker syau-scr04 which linked to the male sterility ...

  4. Radiation sterilization of harmful algae in water

    International Nuclear Information System (INIS)

    Byung Chull An; Jae-Sung Kim; Seung Sik Lee; Shyamkumar Barampuram; Eun Mi Lee; Byung Yeoup Chung

    2007-01-01

    Complete text of publication follows. Objective: Drinking water, water used in food production and for irrigation, water for fish farming, waste water, surface water, and recreational water have been recently recognized as a vector for the transmission of harmful micro-organisms. The human and animal harmful algae is a waterborne risk to public health and economy because the algae are ubiquitous and persistent in water and wastewater, not completely removed by physical-chemical treatment processes, and relatively resistant to chemical disinfection. Gamma and electron beam radiation technology is of growing in the water industry since it was demonstrated that gamma and electron beam radiation is very effective against harmful algae. Materials and Methods: Harmful algae (Scenedesmus quadricauda(Turpin) Brebisson 1835 (AG10003), Chlorella vulgaris Beijerinck 1896 (AG30007) and Chlamydomonas sp. (AG10061)) were distributed from Korean collection for type cultures (KCTC). Strains were cultured aerobically in Allen's medium at 25□ and 300 umol/m2s for 1 week using bioreactor. We investigated the disinfection efficiency of harmful algae irradiated with gamma (0.05 to 10 kGy for 30 min) and electron beam (1 to 19 kGy for 5 sec) rays. Results and Conclusion: We investigated the disinfection efficiency of harmful algae irradiated with gamma and electron beam rays of 50 to 19000 Gy. We established the optimum sterilization condition which use the gamma and electron beam radiation. Gamma ray disinfected harmful algae at 400 Gy for 30 min. Also, electron beam disinfected at 1000 Gy for 5 sec. This alternative disinfection practice had powerful disinfection efficiency. Hence, the multi-barrier approach for drinking water treatment in which a combination of various disinfectants and filtration technologies are applied for removal and inactivation of different microbial pathogens will guarantee a lower risk of microbial contamination.

  5. Tubal anastomosis after previous sterilization: a systematic review.

    Science.gov (United States)

    van Seeters, Jacoba A H; Chua, Su Jen; Mol, Ben W J; Koks, Carolien A M

    2017-05-01

    Female sterilization is one of the most common contraceptive methods. A small number of women, however, opt for reversal of sterilization procedures after they experience regret. Procedures can be performed by laparotomy or laparoscopy, with or without robotic assistance. Another commonly utilized alternative is IVF. The choice between surgery and IVF is often influenced by reimbursement politics for that particular geographic location. We evaluated the fertility outcomes of different surgical methods available for the reversal of female sterilization, compared these to IVF and assessed the prognostic factors for success. Two search strategies were employed. Firstly, we searched for randomized and non-randomized clinical studies presenting fertility outcomes of sterilization reversal up to July 2016. Data on the following outcomes were collected: pregnancy rate, ectopic pregnancy rate, cost of the procedure and operative time. Eligible study designs included prospective or retrospective studies, randomized controlled trials, cohort studies, case-control studies and case series. No age restriction was applied. Exclusion criteria were patients suffering from tubal infertility from any other reason (e.g. infection, endometriosis and adhesions from previous surgery) and studies including sterilization reversal procedures were then evaluated: female age, BMI and duration and method of sterilization. Secondly, we searched for randomized and non-randomized clinical studies that compared reversal of sterilization to IVF and evaluated them for pregnancy outcomes and cost effectiveness. We included 37 studies that investigated a total of 10 689 women. No randomized controlled trials were found. Most studies were retrospective cohort studies of a moderate quality. The pooled pregnancy rate after sterilization reversal was 42-69%, with heterogeneity seen from the different methods utilized. The reported ectopic pregnancy rate was 4-8%. The only prognostic factor affecting the

  6. "Absolute" sterility and "absolute" freedom from particle contamination.

    Science.gov (United States)

    Knapp, J Z

    1998-01-01

    Until the recent past, sterility of an injectable product was only discussed in absolute terms. Any description of sterility other than as an absolute could simply not be envisioned. While dealing in absolute yes/no statements is philosophically satisfying, these yes/no statements can't accommodate all real world scientific problems. Among these problems is the sterility problems faced in the mass production of injectable compounds. Many descriptions of procedures employed to achieve sterility in parenteral production batches were reported in the literature. The theoretical framework that could unite the widespread observations and practices into practical methodology was missing until recently. Production line control of the sterility of injectable products was essentially based on gut evaluations. The present achievement of rational, production line control of product sterility is based on the recognition that product sterility could not be simply regarded as a sharply edged yes/no affair. The present rational control is based on the fact that the sterility of a product is determined by the degree of contamination in the product prior to sterilization and to the parameters of the sterilization process. The end result of the sterilization process is now described as a probabalistic reduction of the initial contamination. The essential laboratory measurements on which this conclusion was based is due to Pflug (1-3). He assembled a theoretical framework, based on experimental data, that characterizes the sterility achieved in an injectable product with a single number. The end result of the sterilization process is now described as a probabalistic reduction of the initial contamination. As in many disciplines, the ability to achieve an objective evaluation of this important attribute provided the basis for scientific analysis, improved control and thus improved production and reduced cost. An equivalent framework is essential for the communication and

  7. Multiple matings among glossina and the sterile male technique

    International Nuclear Information System (INIS)

    Pinhao, R.C.

    1980-01-01

    The fact that multiple matings are a common phenomenon among glossina turns the sterile male technique into a competition not between adult insects but between two types of sperm, and the proportion of females inseminated with the one or the other is given by the binomial (p+q)sup(n), where p is the percentage of normal males, q the percentage of sterile males and n the average number of matings per female. However, multiple matings cannot damage the effectiveness of the technique unless two conditions are present either separately or simultaneously: precocious death of the spermatozoa and reduced inseminating potential among the sterile males. Study of the factors which can alter the inseminating potential is thus important for those who wish to use the sterile male technique. These factors are of three kinds: factors connected with quality, with quantity and with availability. The first are associated with the nature and intensity of the alterations brought about in the spermatozoa by the sterilizing agent, the second with possible variations in the amount of sperm reaching the spermotheca, the third with the behaviour of the sterile males in the nature - that is, the question whether sterilization has a favourable or unfavourable influence on their chances of mating with wild females. The author describes his observations of the quantity of sperm produced by Glossina morsitans submorsitans males from the colony reared at the Institute for Tropical Hygiene and Medicine in Lisbon, compares them with the observations of other authors and discusses their practical significance. Specific research is suggested. Advantages from assessing the behaviour of colonies not by female productivity but by male inseminating potential, and appropriate laboratory techniques

  8. Prospects for radiation sterilization of medical products in Egypt

    International Nuclear Information System (INIS)

    Roushdy, H.M.

    1975-01-01

    The pharmaceutical industry in Egypt is continually expanding its activity and each year marks new accomplishments and additions which enable the companies to apply the most modern scientific means in the production of pharmaceutical preparations and consequently to improve their market potentialities. The certainty of expansion and the possibility of increasing exports of sterilized medical products, particularly to Arab and African countries, indicate a need for a gamma-sterilization plant. This technology permits the introduction of the latest practices with regard to used disposables, thus greatly reducing the chances of cross-contamination which usually results in serious complications enhanced by local environmental conditions. This paper reviews the current state and future prospects for radiation sterilization of medical products and biological tissues in connection with other related industrial radiation processings. Moreover, the paper reviews the Egyptian scientific and technical experience with irradiation facilities and the parameters underlying the choice of Egypt's first industrial gamma and electron-beam irradiators designed for more than a single-purpose use, with hygienic measures taken to avoid biological contamination of sterilized medical packages throughout the sterilization process. In addition, the paper deals with the policy set up for establishing the Egyptian National Centre for Radiation Technology with a view to introducing irradiation techniques in the sterilization of medical products, and to improving the properties and increasing the competitiveness of Egyptian fabrics. Apart from medical sterilization, certain industrial processes have been mentioned to show how a multi-purpose irradiation facility may be utilized in a developing country to justify significantly the large investment required. (author)

  9. Temperature Effects on Free Radicals in Gamma-sterilized Beef

    Science.gov (United States)

    Pramanik, S. I.; Jahan, M. S.

    1999-11-01

    Gamma irradiation has become the method of choice for sterilizing frozen meat and their products to reduce levels of food-borne pathogens and to extend shelf life. In this report we have employed ESR technique for detection of free radicals in sterilized and non-sterilized dry beef without bone. We have also determined the heating effects on free radicals at temperatures 176^°C and 250^°C. Meat samples were dried in a food dehydrator at 60^°C and were packaged in dry N_2. They were then sterilized by γ-irradiation (2.5 MRad), ground into powder, and placed in ESR sample tubes. Non-sterilized powder samples were used as control. While all powder samples, sterilized or not, produced a broad single line in the ESR spectra with (Δ H_pp ~ 9 G) and g = 2.013, the radical concentration in the sterilized samples increased by a factor of five. Heat treatment at 176^°C produced similar radicals. But, when samples were heated 250^°C different radical species were formed which are characterized by narrow width (Δ H_pp ~ 6 G) and lower g-value (g =2.010). In contrast with previous work, where free radicals in chicken bones were reduced by heating [1], we observed an increase in concentration. Results of structural analyses of the radicals will be presented. Ref.[1]: Radiat. Phys. Chem., 49, 477-481, 1997. Work supported by Grants from the University of Memphis

  10. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: an in vitro study.

    Science.gov (United States)

    Venkatasubramanian, R; Das, U M; Bhatnagar, S

    2010-01-01

    Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde) and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  11. Reliability of Laparoscopic Compared With Hysteroscopic Sterilization at One Year: A Decision Analysis

    Science.gov (United States)

    Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.

    2011-01-01

    OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842

  12. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: An in vitro study

    Directory of Open Access Journals (Sweden)

    Venkatasubramanian R

    2010-03-01

    Full Text Available Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  13. Vasectomy occlusion techniques for male sterilization.

    Science.gov (United States)

    Cook, L A; Vliet, H; Pun, A; Gallo, M F

    2004-01-01

    Vasectomy is an increasingly popular and effective family planning method. A variety of vasectomy techniques are used worldwide including various vas occlusion techniques (excision and ligation, thermal or electrocautery, and mechanical and chemical occlusion methods), vas irrigation and fascial interposition. Vasectomy guidelines largely rely on information from observational studies. Ideally, the choice of vasectomy techniques should be based on the best available evidence from randomized controlled trials. The objective of this review was to compare the effectiveness, safety, acceptability and costs of vasectomy techniques for male sterilization. We searched the computerized databases the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Popline and LILACS. In addition, we searched the reference lists of relevant articles and book chapters. We included randomized controlled trials and controlled clinical trials comparing vasectomy techniques. We assessed all titles and abstracts located in the literature searches and two reviewers independently extracted articles identified for inclusion. Data were presented in the text of the review. Outcome measures include contraceptive efficacy, safety, discontinuation, and acceptability. Two trials compared vas occlusion with clips versus a conventional vasectomy technique; both were of poor quality. Neither trial found a difference between the two groups with regard to the primary outcome of failure to reach azoospermia. Four trials examined vas irrigation: three compared water irrigation with no irrigation and one compared water irrigation with euflavine. All of the trials were of poor quality. None of the trials found a significant difference between the groups with respect to the primary outcome of time to azoospermia. However, one trial found that the median number of ejaculations to azoospermia was significantly lower in the euflavine group compared to the water irrigation group. The one trial

  14. A preliminary evaluation of a reusable digital sterilization indicator prototype.

    Science.gov (United States)

    Puttaiah, R; Griggs, J; D'Onofrio, M

    2014-09-01

    Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of sterilizers. Data loggers or independent digital parametric indicators are innovative devices that provide more information than various classes chemical indicators. In this study we evaluated a prototype of an independent digital parametric indicator's use in autoclaves. The purpose of this study was to evaluate the performance of an independent digital indicator/data logger prototype (DS1922F) that could be used for multiple cycles within an autoclave.MG Materials and methods: Three batches of the DS1922F (150 samples) were used in this study that was conducted in a series. The first batch was challenged with 300 sterilization cycles within an autoclave and the data loggers evaluated to study failures and the reason for failure, make corrections and improve the prototype design. After changes made based on studying the first batch, the second batch of the prototype (150 samples) were challenged once again with 300 sterilization cycles within an autoclave and failure studied again in further improvement of the prototype. The final batch (3rd batch) of the prototype (150 samples) was challenged again but with 600 cycles to see how long they would last. Kaplan-Meier survival analysis analyses of all three batches was conducted (α = 0.05) and failed samples qualitatively studied in understanding the variables involved in the failure of the prototype, and in improving quality. Each tested batch provided crucial information on device failure and helped in improvement of the prototype. Mean lifetime survival of the final batch (Batch 3) of prototype was 498 (480, 516) sterilization cycles

  15. Developing transgenic Anopheles mosquitoes for the sterile insect technique.

    Science.gov (United States)

    Nolan, Tony; Papathanos, Philippos; Windbichler, Nikolai; Magnusson, Kalle; Benton, Jason; Catteruccia, Flaminia; Crisanti, Andrea

    2011-01-01

    In the last 10 years the availability of the genome sequence of Anopheles gambiae and the development of a transgenic technology for several species of Anopheles mosquitoes have, in combination, helped in enabling us to gain several insights into the biology of these mosquitoes that is relevant to their capacity as vectors of the malaria parasite. While this information is anticipated to inform many novel vector control strategies, the technique most likely to benefit in the near future from the availability of a reliable transgenic technology is the sterile insect technique (SIT), which relies on releasing large numbers of sterile insects to compete for mates in the wild, leading to population suppression. Although SIT has been proven to work reliably for many insects, the construction of suitable strains, and induction of sterility, has until now been a laborious process, combining classical genetics with radiation-induced sterility. Using transgenesis to create strains of Anopheles suitable for SIT could potentially offer several advantages over current approaches, in that the basic design of transgenic constructs designed for other insects should be rapidly transferable to mosquitoes, and induction of sterility as a product of the transgenic modification could obviate the requirement for radiation and its associated deleterious effects. In this paper the progress of different transgenic approaches in constructing tools for SIT will be reviewed.

  16. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    International Nuclear Information System (INIS)

    Huang, Junting

    2015-01-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states v e , v μ and v τ . In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ 24 in the range of 10 -2 eV 2 < Δm 43 2 < 1 eV 2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  17. Search for heavy sterile neutrinos in trileptons at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Claudio O. [Univ. Tecnica Federico Santa Maria, Valparaiso (Chile). CCTVal y Dept. of Physics; Kim, C.S. [Yonsei Univ., Seoul (Korea, Republic of). Dept. of Physics and IPAP; Wang, Kechen [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Chinese Academy of Sciences, Beijing (China). Center for Future High Energy Physics

    2017-03-15

    We present a search strategy for both Dirac and Majorana sterile neutrinos from the purely leptonic decays of W{sup ±}→e{sup ±}e{sup ±}μ{sup -+}ν and μ{sup ±}μ{sup ±}e{sup -+}ν at the 14 TeV LHC. The discovery and exclusion limits for sterile neutrinos are shown using both the Cut-and-Count (CC) and Multi-Variate Analysis (MVA) methods. We also discriminate between Dirac and Majorana sterile neutrinos by exploiting a set of kinematic observables which differ between the Dirac and Majorana cases. We find that the MVA method, compared to the more common CC method, can greatly enhance the discovery and discrimination limits. Two benchmark points with sterile neutrino mass m{sub N}=20 GeV and 50 GeV are tested. For an integrated luminosity of 3000 fb{sup -1}, sterile neutrinos can be found with 5σ significance if heavy-to-light neutrino mixings vertical stroke U{sub Ne} vertical stroke {sup 2}∝ vertical stroke U{sub Nμ} vertical stroke {sup 2}∝10{sup -6}, while Majorana vs. Dirac discrimination can be reached if at least one of the mixings is of order 10{sup -5}.

  18. Microbiological evaluation of the steam sterilization of assembled laparoscopic instruments

    Directory of Open Access Journals (Sweden)

    Tamara Carolina de Camargo

    Full Text Available ABSTRACT Objective: assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination. Method: a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator. Three of them were introduced into each instrument at the time of assembly, and sterilized at pressurized saturated steam, 134oC for 5 minutes. After sterilization, the instrument was disassembled and each filter paper substrate was inoculated in soybean casein culture and incubated at 56oC for 21 days. In case of absence of growth, they were subjected to heat shock of 80oC, for 20 minutes and re-incubated for 72 hours. Sample size: 185 graspers and 185 trocars, with 95% power. We paired the experiments with comparative negative control groups (5 graspers and 5 trocars with challenge contamination, sterilized disassembled and positive control (30 filter paper supports, unsterilized, subject to the same incubation procedures. Results: there was no microbial growth in experimental and negative control. The results of the positive control were satisfactory. Conclusion: this study provided strong scientific evidence to support the safety of steam sterilizing of the assembled laparoscopic instrument.

  19. Research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang; Ouyang Qiongli

    2010-01-01

    Radiation sterilization is widely applied in food processing, pharmaceutical manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. There are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the restrictions of capacity and inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  20. Search for heavy sterile neutrinos in trileptons at the LHC

    International Nuclear Information System (INIS)

    Dib, Claudio O.; Kim, C.S.; Wang, Kechen; Chinese Academy of Sciences, Beijing

    2017-03-01

    We present a search strategy for both Dirac and Majorana sterile neutrinos from the purely leptonic decays of W ± →e ± e ± μ -+ ν and μ ± μ ± e -+ ν at the 14 TeV LHC. The discovery and exclusion limits for sterile neutrinos are shown using both the Cut-and-Count (CC) and Multi-Variate Analysis (MVA) methods. We also discriminate between Dirac and Majorana sterile neutrinos by exploiting a set of kinematic observables which differ between the Dirac and Majorana cases. We find that the MVA method, compared to the more common CC method, can greatly enhance the discovery and discrimination limits. Two benchmark points with sterile neutrino mass m N =20 GeV and 50 GeV are tested. For an integrated luminosity of 3000 fb -1 , sterile neutrinos can be found with 5σ significance if heavy-to-light neutrino mixings vertical stroke U Ne vertical stroke 2 ∝ vertical stroke U Nμ vertical stroke 2 ∝10 -6 , while Majorana vs. Dirac discrimination can be reached if at least one of the mixings is of order 10 -5 .

  1. [Surgical sterilization failure: a study of 290 cases].

    Science.gov (United States)

    Trias Fargas, M

    1981-01-01

    This study seeks to establish the failure rate of sterilizations in the Profamilia pilot clinic in Bogota, and analyzes the chronology of the resulting pregnancies and their possible causes and the reactions of the women who became pregnant. 31,828 sterilizations were performed in the clinic between 1973 and 1980, 8% of them minilaparotomies. 272 of 290 pregnancies diagnosed after sterilization were method failures, the other 18 having begun before the operation. Almost 60% of the pregnancies occurred within 1 year of the operation, and all but 4% occurred within 4 years. The rate calculated on the basis of the 1st 12,000 sterilizations, 142 of which were followed by pregnancies due to method failure, was 1.18%, or 1 case per 85 operations. The average age of the women who became pregnant was 31.0 years, compared to the average of 33.4 years for all women undergoing sterilization. Possible reasons for the failures are discussed, including incomplete follow-up, defective materials, surgical skill, and the performance of operations by students. Analyses of 157 cases of reinterventions indicate that 27% of the failures resulted from human error and the rest from method imperfections including incomplete occlusion of the tube, recanalization, and refistulization. 7.35% of the pregnancies were ectopic. 33.8% of the women who became pregnant bore children, 11.7% had spontaneous abortions, and 54.5% sought induced abortions.

  2. Closing in on resonantly produced sterile neutrino dark matter

    Science.gov (United States)

    Cherry, John F.; Horiuchi, Shunsaku

    2017-04-01

    We perform an exhaustive scan of the allowed resonant production regime for sterile neutrino dark matter in order to improve constraints for dark matter structures which arise from the nonthermal sterile neutrino energy spectra. Small-scale structure constraints are particularly sensitive to large lepton asymmetries/small mixing angles which result in relatively warmer sterile neutrino momentum distributions. We revisit Milky Way galaxy subhalo count constraints and combine them with recent searches for x-ray emission from sterile neutrino decays. Together, they rule out models outside the mass range 7.0 keV ≤mνs≤36 keV and lepton asymmetries smaller than 15 ×10-6 per unit entropy density at 95% confidence interval or greater. We also find that, while a portion of the parameter space remains unconstrained, the combination of subhalo counts and x-ray data indicates the candidate 3.55 keV x-ray line signal potentially originating from a 7.1 keV sterile neutrino decay to be disfavored at 93% confidence interval.

  3. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Junting [Univ. of Texas, Austin, TX (United States)

    2015-05-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states ve, vμ and vτ. In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ24 in the range of 10-2 eV2 < Δm412 < 1 eV2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  4. Population suppression in support of the sterile insect technique

    International Nuclear Information System (INIS)

    Mangan, R.L.

    2005-01-01

    Suppression or eradication of insect pest populations by the release of sterile insects is often dependent on supplementary methods of pest reduction to levels where the target pest population can be overflooded with sterile insects. Population suppression activities take place in advance of, or coincide with, the production of sterile insects. Supplementary methods to remove breeding opportunities, or management methods that prevent access of pests to the hosts, may reduce the population or prevent damage. Insecticides have been used widely in direct applications or applied as baits, in traps, or on specific sites where the pest makes contact or reproduces. As sterile insect release does not kill the pest, adult biting pests or fertile mated females of the pests will continue to attack hosts after the release of sterile insects. Thus supplementary pest suppression programmes and quarantine measures are essential to prevent damage or the spread of disease. Eradication or effective pest management requires that the entire population of the pest be treated, or that the programme apply immigration barriers. When supplementary pest control activities benefit the human population in areas being treated, such as in mosquito or screwworm eradication programmes, these activities are usually acceptable to the public, but when the public receives no direct benefit from supplementary control activities such as in fruit fly programmes, social resistance may develop. (author)

  5. Electron beam sterilization of water discharged from sewage

    International Nuclear Information System (INIS)

    Miyata, Teijiro; Arai, Hidehiko; Tokunaga, Okihiro; Machi, Sueo; Kondo, Masaki; Minemura, Takashi; Nakao, Akio; Seike, Yasuhiko.

    1989-01-01

    At present, the water treated at city sewerages is discharged to rivers after the chlorine sterilization, but it was clarified recently that this chlorine treatment produces carcinogenic organic chlorine compounds, and residual chlorine exerts harmful effect to aquatics, therefore, it is desirable to develop the sterilization techniques substituting for chlorine treatment. Already many reports elucidated that irradiation is effective for the sterilization of the water discharged from sewerage. However, as the technical subject for putting radiation process in practical use, the treatment of large quantity was a problem. Recently by the progress of the technology of manufacturing electron accelerators, the equipment with large power output which can treat in large quantity was developed, and it has become applicable also to sewage treatment. Therefore, the authors examined the practicality of electron beam process as the substitute technology for chlorine sterilizaiton. In the case of using electron beam, though the power output of accelerators is large, the flight range of electron beam in water is short. The comparison of the sterilization effect of electron beam with that of Co-60 gamma ray, the effects of water depth, discharged water quality and water velocity on the sterilization effect and so on were experimentally examined. (K.I.)

  6. Vasectomy occlusion techniques for male sterilization.

    Science.gov (United States)

    Cook, Lynley A; Van Vliet, Huib A A M; Lopez, Laureen M; Pun, Asha; Gallo, Maria F

    2014-03-30

    Vasectomy is an increasingly popular and effective family planning method. A variety of vasectomy techniques are used worldwide, including vas occlusion techniques (excision and ligation, thermal or electrocautery, and mechanical and chemical occlusion methods), as well as vasectomy with vas irrigation or with fascial interposition. Vasectomy guidelines largely rely on information from observational studies. Ideally, the choice of vasectomy techniques should be based on the evidence from randomized controlled trials (RCTs). The objective of this review was to compare the effectiveness, safety, acceptability and costs of vasectomy techniques for male sterilization. In February 2014, we updated the searches of CENTRAL, MEDLINE, POPLINE and LILACS. We looked for recent clinical trials in ClinicalTrials.gov and the International Clinical Trials Registry Platform. Previous searches also included EMBASE. For the initial review, we searched the reference lists of relevant articles and book chapters. We included RCTs comparing vasectomy techniques, which could include suture ligature, surgical clips, thermal or electrocautery, chemical occlusion, vas plugs, vas excision, open-ended vas, fascial interposition, or vas irrigation. We assessed all titles and abstracts located in the literature searches. Two reviewers independently extracted data from articles identified for inclusion. Outcome measures include contraceptive efficacy, safety, discontinuation, and acceptability. Peto odds ratios (OR) with 95% confidence intervals (CI) were used for dichotomous outcomes, such as azoospermia. The mean difference (MD) was used for the continuous variable of operating time. Six studies met the inclusion criteria. One trial compared vas occlusion with clips versus a conventional vasectomy technique. No difference was found in failure to reach azoospermia (no sperm detected). Three trials examined vasectomy with vas irrigation. Two studies looked at irrigation with water versus no

  7. Estimation of populations and sterility induction in Anastrepha ludens (Diptera: Tephritidae) fruit flies

    International Nuclear Information System (INIS)

    Flores, Salvador; Montoya, Pablo; Toledo, Jorge; Liedo, Pablo; Enkerlin, Walther

    2015-01-01

    The relationship between different release densities of sterile flies and fly trap captures, expressed as flies per trap per day, in the monitoring of Anastrepha ludens (Loew) populations was evaluated in mango orchards. The induction of sterility in fertile females was evaluated using different ratios of sterile: fertile males under field cage conditions. A direct relationship between recaptured flies and densities of release sterile flies was found. However, trap efficiency, expressed as percentage of recaptured flies, decreased as the density of released flies increased. Sterility induction was positively correlated to the ratio of sterile: fertile flies. A significant difference in egg fertility among treatments was observed. The trajectory of sterility induction slowed down after a sterile: wild ratio of 30:1, which suggests that this ratio could be appropriate in an sterile insect technique program with A. ludens. Sterility induction was greater when only sterile males were released than when releasing both sterile males and females, but the differences were not significant. Our findings contribute to a better interpretation of fly captures obtained from the field trapping networks, and to an improvement in the efficiency of sterile insect technique against A. ludens fruit flies, through the implementation of more rational sterile fly release densities. (author)

  8. Sterilization regret among married women in India: implications for the Indian national family planning program.

    Science.gov (United States)

    Singh, Abhishek; Ogollah, Reuben; Ram, Faujdar; Pallikadavath, Saseendran

    2012-12-01

    In India, female sterilization accounts for 66% of contraceptive use, and age at sterilization is declining. It is likely that some women regret having been sterilized, but data on the prevalence of, and the social and economic correlates of, regret at the national level are insufficient. Data for analysis came from 30,999 sterilized women aged 15-49 interviewed in the 2005-2006 Indian National Family Health Survey. Logistic regression analyses and Wald tests were used to identify the social and demographic characteristics associated with sterilization regret. Nationally, 5% of sterilized women aged 15-49 reported sterilization regret. Women sterilized at age 30 or older were less likely than women sterilized before age 25 to express regret (odds ratio, 0.8). Compared with women having only sons, those who had only daughters were more likely to express regret (1.3), while those having both sons and daughters were less likely to express regret (0.8). Women who had experienced child loss had higher odds of reporting regret than women who had not (for one child lost, 1.6; for two or more children lost, 2.0). Given the large proportion of women undergoing sterilization, the potential numbers experiencing regret are considerable. If age at sterilization continues to decline, sterilization regret is likely to increase. Encouraging couples to delay sterilization and increasing the availability of highly effective reversible contraceptives are options that India may consider to avert sterilization regret.

  9. Sterility inheritance in the irradiated European Corn Borer

    International Nuclear Information System (INIS)

    Rosca, I.; Barbulescu, Al.

    1990-01-01

    The inherited sterility in F 1 and F 2 of the European Corn Borer (Ostrinia nubilalis Hb.) irradiated with sub-sterilizing doses of 10 and 15 Krad has been studied at Research Institute for Cereals and Industrial Crops, Fundulea, Romania. Irradiations were done with a 60 Co source delivering 1,805 roentgen/h/m in containers of 23 mm diameter and 125 mm height, placed apart from the 60 Co source. Following irradiation of male parent generation, no significant differences were recorded in F 1 and F 2 referring to the number of deposited egg-batches and adult longevity. Nevertheless, there was a significant decrease of the percentage of viable eggs and an increase of the number of sterile couples. (author)

  10. Sterile neutrino portal to Dark Matter II: exact dark symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Escudero, Miguel; Rius, Nuria [Universidad de Valencia-CSIC, Departamento de Fisica Teorica and IFIC, C/Catedratico Jose Beltran, 2, 46980, Paterna (Spain); Sanz, Veronica [University of Sussex, Department of Physics and Astronomy, Brighton (United Kingdom)

    2017-06-15

    We analyze a simple extension of the standard model (SM) with a dark sector composed of a scalar and a fermion, both singlets under the SM gauge group but charged under a dark sector symmetry group. Sterile neutrinos, which are singlets under both groups, mediate the interactions between the dark sector and the SM particles, and generate masses for the active neutrinos via the seesaw mechanism. We explore the parameter space region where the observed Dark Matter relic abundance is determined by the annihilation into sterile neutrinos, both for fermion and scalar Dark Matter particles. The scalar Dark Matter case provides an interesting alternative to the usual Higgs portal scenario. We also study the constraints from direct Dark Matter searches and the prospects for indirect detection via sterile neutrino decays to leptons, which may be able to rule out Dark Matter masses below and around 100 GeV. (orig.)

  11. Study on stable fly eradication by sterile-male technique

    International Nuclear Information System (INIS)

    Chung, K.H.; Ryu, J.; Kwon, S.H.

    1975-01-01

    This experiment was performed to investigate the X-ray sensitivities at the various stages of life cycle and to determine the sterillizing dose of stable fly, Stomoxys calcitrans(L). A dose of 300 rad caused about 50% mortality in 2-hour-old eggs as measured by egg hatch, and 100% mortality was obtained with a dose of 1 Krad. Sub-lethal dose (LDsub(50)) for the pupal age at irradiation. A significant reduction of egg hatch by 1.5% was observed when treated males with 3 Krad at pupal stage were mated to untreated virgin females. On the other hand, 100% sterility in females was resulted by Krad irradiation and oviposition was completely inhibited with 3 Krad. Thus, both sexes of stable fly could be sterilized with a dose of 4 Krad irradiated 50 3-5 days old pupae. (author)

  12. Displaced vertex searches for sterile neutrinos at future lepton colliders

    Energy Technology Data Exchange (ETDEWEB)

    Antusch, Stefan [Department of Physics, University of Basel, Klingelbergstr. 82, CH-4056 Basel (Switzerland); Max-Planck-Institut für Physik (Werner-Heisenberg-Institut),Föhringer Ring 6, D-80805 München (Germany); Cazzato, Eros; Fischer, Oliver [Department of Physics, University of Basel, Klingelbergstr. 82, CH-4056 Basel (Switzerland)

    2016-12-02

    We investigate the sensitivity of future lepton colliders to displaced vertices from the decays of long-lived heavy (almost sterile) neutrinos with electroweak scale masses and detectable time of flight. As future lepton colliders we consider the FCC-ee, the CEPC, and the ILC, searching at the Z-pole and at the center-of-mass energies of 240, 350 and 500 GeV. For a realistic discussion of the detector response to the displaced vertex signal and the Standard Model background we consider the ILC’s Silicon Detector (SiD) as benchmark for the future lepton collider detectors. We find that displaced vertices constitute a powerful search channel for sterile neutrinos, sensitive to squared active-sterile mixing angles as small as 10{sup −11}.

  13. The Sterile Insect Technique as a method of pest control

    International Nuclear Information System (INIS)

    Argiles Herrero, R.

    2011-01-01

    In the Valencia community is doing one of the most ambitious project in the field of plant protection at European level: the fight against fruit fly, one of the most damaging pests of citrus and fruit; by Insect Technique Sterile. This technique consists of laboratory breeding and release into the fields of huge quantities of insects of the pest species that have previously been sterilized. Sterile insect looking for wild individuals of the same species to mate with them and the result is a clutch of viable eggs, causing a decrease in pest populations. After three years of application of the technique on an area of 150,000 hectares, the pest populations have been reduced by 90%. Other benefits have been the reduced used of insecticides and improved the quality of exported fruit. (Author)

  14. Sterilization of Turmeric by Atmospheric Pressure Dielectric Barrier Discharge Plasma

    International Nuclear Information System (INIS)

    Salarieh Setareh; Dorranian Davoud

    2013-01-01

    In this study atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed for sterilizing dry turmeric powders. A 6 kV, 6 kHz frequency generator was used to generate plasma with Ar, Ar/O 2 , He, and He/O 2 gases between the 5 mm gap of two quartz covered electrodes. The complete sterilization time of samples due to plasma treatment was measured. The most important contaminant of turmeric is bacillus subtilis. The results show that the shortest sterilization time of 15 min is achieved by exposing the samples to Ar/O 2 plasma. Survival curves of samples are exponential functions of time and the addition of oxygen to plasma leads to a significant increase of the absolute value of time constant of the curves. Magnitudes of protein and DNA in treated samples were increased to a similar value for all samples. Taste, color, and solubility of samples were not changed after the plasma treatment

  15. Sterilization of Turmeric by Atmospheric Pressure Dielectric Barrier Discharge Plasma

    Science.gov (United States)

    Setareh, Salarieh; Davoud, Dorranian

    2013-11-01

    In this study atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed for sterilizing dry turmeric powders. A 6 kV, 6 kHz frequency generator was used to generate plasma with Ar, Ar/O2, He, and He/O2 gases between the 5 mm gap of two quartz covered electrodes. The complete sterilization time of samples due to plasma treatment was measured. The most important contaminant of turmeric is bacillus subtilis. The results show that the shortest sterilization time of 15 min is achieved by exposing the samples to Ar/O2 plasma. Survival curves of samples are exponential functions of time and the addition of oxygen to plasma leads to a significant increase of the absolute value of time constant of the curves. Magnitudes of protein and DNA in treated samples were increased to a similar value for all samples. Taste, color, and solubility of samples were not changed after the plasma treatment.

  16. Study on the sterilization of egg white powder by irradiation

    International Nuclear Information System (INIS)

    Fu Lixin; Meng Lifen; Zhao Xiaonan; Xu Dechun; Hu Shaoxin; Chen Changdong; Wang Zhidong

    2013-01-01

    The sterilizing effect, influence on main essential nutrient and sensory qualities of egg white powder treated with 60 Co γ-ray irradiation were studied. The microorganism index of egg white powder samples treated with 4 kGy irradiation could meet the government food sanitation standard, and the sterilization rate could reach 100%. The irradiation doses from 4 to 10 kGy had little influence on egg white powder protein, crude fiber and amino acidscontent, and the sensory quality such as color, luster, and scent changed little below 6 kGy irradiation. Considering the result of this study, the optimal irradiation dose for egg white powder sterilization was 4 to 6 kGy. (authors)

  17. The Rise of Female Sterilization: A Closer Look at Colombia.

    Science.gov (United States)

    Folch, Beatriz M; Betstadt, Sarah; Li, Dongmei; Whaley, Natalie

    2017-09-01

    Objective In the 1970s, OCPs and IUDs were the most popular contraceptive methods in Colombia. According to data from the most recent Demographic and Health Survey (DHS), sterilization has become the most common form of birth control in Colombia. This study aims to examine the characteristics of Colombian women desiring long-acting contraception. Methods This study uses the 2005 and 2010 Colombian DHS dataset. Women who choose long-acting contraception were divided into those using female sterilization and those using long-acting reversible contraception (LARC). A multivariate logistic regression model was used to compare demographic and social determinants of contraceptive choice among reproductive age women seeking long-acting contraception between the years 2005 and 2010. Results Among women using a long-acting contraceptive method in 2010, compared to 2005, women were significantly more likely to be sterilized (1.14 OR, 95% CI 1.09-1.18) and less likely to use LARC (0.88 OR, 95% CI 0.85-0.92). Of women seeking long-acting contraception, those exposed to a family planning provider were less likely to undergo sterilization (0.54 OR, 95% CI 0.51-0.58) and more likely to use LARC (1.84 OR, 95% CI 1.73-1.96). When compared to all contraceptive users, younger women and women with less than two children were more likely to use LARC than sterilization. Conclusion Between 2005 and 2010, an increase in the proportion of contracepting women being sterilized in Colombia occurred. Our findings suggest that exposure to a family planning provider and appropriate contraceptive counseling appears to be key determinants of long-acting contraceptive choice. To improve use of long-acting, effective contraception, efforts should be made to increase access to family planning providers.

  18. Low temperature gamma sterilization of a bioresorbable polymer, PLGA

    Science.gov (United States)

    Davison, Lisa; Themistou, Efrosyni; Buchanan, Fraser; Cunningham, Eoin

    2018-02-01

    Medical devices destined for insertion into the body must be sterilised before implantation to prevent infection or other complications. Emerging biomaterials, for example bioresorbable polymers, can experience changes in their properties due to standard industrial sterilization processes. Gamma irradiation is one of the most reliable, large scale sterilization methods, however it can induce chain scission, cross-linking or oxidation reactions in polymers. sterilization at low temperature or in an inert atmosphere has been reported to reduce the negative effects of gamma irradiation. The aim of this study was to investigate the impact of low temperature sterilization (at -80 °C) when compared to sterilization at ambient temperature (25 °C) both in inert atmospheric conditions of nitrogen gas, on poly(lactide co-glycolide) (PLGA). PLGA was irradiated at -80 and 25 °C at 40 kGy in a nitrogen atmosphere. Samples were characterised using differential scanning calorimetry (DSC), tensile test, Fourier transform infrared (FTIR) spectroscopy, proton nuclear magnetic resonance (1H NMR) spectroscopy and gel permeation chromatography (GPC). The results showed that the molecular weight was significantly reduced as was the glass transition temperature, an indication of chain scission. FTIR showed small changes in chemical structure in the methyl and carbonyl groups after irradiation. Glass transition temperature was significantly different between irradiation at -80 °C and irradiation at 25 °C, however this was a difference of only 1 °C. Ultimately, the results indicate that the sterilization temperature used does not affect PLGA when carried out in a nitrogen atmosphere.

  19. Absorption capacity and toxicity of paper points after sterilization

    Directory of Open Access Journals (Sweden)

    Mirian Marubayashi Hidalgo

    2008-01-01

    Full Text Available Objective: To evaluate the influence of the sterilization process on paper cones as regards their absorption capacity, and consequently, root canal drying, in addition to the possible release of any antimicrobial or cytotoxic product. Methods: The cones used were of three of the brands found on the Brazilian market Dentsply (Dentsply Indústria e Comércio Ltda., Petrópolis, Brazil, Endopoints (Endopoints Indústria e Comércio Ltda., Paraíba do Sul, Brazil and Tanari (Tanari Industrial Ltda., São Paulo, Brazil. To evaluate the absorption capacity, the cones were submitted to four sterilization cycles, and the modified Holland technique was performed. The antimicrobial/cytotoxic capacity was verified by means of depositing the sterilized cones in Petri dishes containing Miller-Hinton Agar and Blood Agar, seeded with S.aureus and E. coli. Results: The Dentsply (Dentsply Indústria e Comércio Ltda., Petrópolis, Brazil and Tanari (Tanari Industrial Ltda., São Paulo, Brazilcones presented greater absorption after the first sterilization cycle, followed by a drop in the second and third cycles, and a new increase in the fourth cycle. For the Endopoints (Endopoints Indústria e Comércio Ltda., Paraíba do Sul, Brazil cones, the values were inverted, with a small drop in absorption after the first cycle, increase in the second and third cycles, and a new drop in the fourth cycle. None of the cones presented antimicrobial activity after the sterilization process. Conclusion: The sterilization process by damp heat does not alter the properties of absorption and there is no release of by-products from the tested paper cones.

  20. Sterilization of rural and urban women in the United States.

    Science.gov (United States)

    Lunde, Britt; Rankin, Kristin; Harwood, Bryna; Chavez, Noel

    2013-08-01

    To examine the prevalence of sterilization among women aged 20-34 years in rural and urban areas in the United States. Data were obtained from the 2006-2010 National Survey of Family Growth, a cross-sectional survey conducted by the Centers for Disease Control and Prevention. The study population included the 4,685 female respondents who did not want to become pregnant at the time of the survey. Women who were not sexually active with men or were infertile for reasons other than contraception were excluded. We performed bivariate and stratified analysis and multivariable logistic regression modeling to determine the associations between place of residence and sterilization after considering other demographic characteristics. Rural women were at increased odds of undergoing sterilization compared with urban and suburban women (22.75% compared with 12.69%, respectively; crude odds ratio [OR] 2.03, 95% confidence interval [CI] 1.44-2.86; risk difference 0.10, 95% CI 0.05-0.16). Education level was found to be a significant effect modifier of the relationship between location of residence and sterilization. In adjusted analysis, controlling for age, parity, race and ethnicity, income, insurance status, history of unintended pregnancy, and relationship status, rural women without a high school degree were more likely to have undergone sterilization compared with urban and rural women with greater than a high school education (OR 8.34, 95% CI 4.45-15.61). Rural women with low education levels have a high prevalence of sterilization. Future studies need to address the reasons for this interaction between education and geography and its influence on contraceptive method choice. II.

  1. Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2007-01-01

    This part of ISO 11135 describes requirements that, if met, will provide an ethylene oxide sterilization process intended to sterilize medical devices, which has appropriate microbicidal activity. Furthermore, compliance with the requirements ensures that this activity is both reliable and reproducible so that it can be predicted, with reasonable confidence, that there is a low level of probability of there being a viable microorganism present on product after sterilization. Specification of this probability is a matter for regulatory authorities and may vary from country to country. The paper provides information on scope, normative references, terms and definitions, quality management systems, sterilizing agent characterization, process and equipment characterization, product definition, process definition, validation, routine monitoring and control, product release from sterilization and maintaining process effectiveness followed by Annex A (Determination of lethal rate of the sterilization process - Biological indicator/bioburden approach), Annex B (Conservative determination of lethal rate of the sterilization process - Overkill approach, annex C (General guidance) and a bibliography.

  2. Ar + NO microwave plasmas for Escherichia coli sterilization

    International Nuclear Information System (INIS)

    Hueso, Jose L; Rico, Victor J; Cotrino, Jose; Gonzalez-Elipe, Agustin R; Frias, Jose E

    2008-01-01

    Ar + NO microwave discharges are used for sterilization and the results are compared with additional experiments with Ar, O 2 and N 2 -O 2 plasma mixtures. The NO * species produced in the Ar-NO mixtures remain up to long distances from the source, thus improving the sterilization efficiency of the process. E. coli individuals exposed to the Ar + NO plasma undergo morphological damage and cell lysis. Combined effects of etching (by O * and Ar * species) and UV radiation (from deactivation of NO * species) are responsible for the higher activity found for this plasma mixture. (fast track communication)

  3. Control of anoplophora glabripennis by releasing sterile insects

    International Nuclear Information System (INIS)

    Liu Xiaohui; Li Yongjun; Zhang Shuyong; Wang Endong; Lu Daguang

    2003-01-01

    An experiment to evaluate the effect of released sterile insects on reproduction of natural A. glabripennis population was conducted at a 30-hectare poplar tree forest in Ying County of Shanxi Province from July 10 to August 29, 2001. Though the releasing ratio was only about 2-5, results from different methods showed that the reproduction of natural A. glabripennis population was suppressed effectively by releasing sterile insects, and that hatch ratio of eggs laid by parent generation was about 20% and survival ratio of F1 progeny about 27%. (authors)

  4. Insect population control by the sterile-male technique

    International Nuclear Information System (INIS)

    Lindquist, A.W.

    1963-01-01

    The successful use of the sterile male technique to eradicate the screw worm fly from the Southeastern part of the United States showed that a new biological method using radiation-sterilized insects could not only control but also eradicate harmful insect pests. A panel of experts met at the IAEA in Vienna in October 1962 to discuss the various aspects and applications of this new technique and to assess its usefulness and limitations. This report summarizes the panel proceedings. 42 refs, 18 figs, 1 tab

  5. Implication of sterile fermions in particle physics and cosmology

    International Nuclear Information System (INIS)

    Lucente, M.

    2015-01-01

    The Ph.D. thesis work summarised in this manuscript was dedicated to studying several aspects of the phenomenology of Standard Model (SM) extensions by sterile fermions, in particular their impact for particle and astro-particle physics. An important part of the work is dedicated to a class of SM extensions which allow to explain the smallness of the observed neutrino masses (as well as their mixings) by linking them to the breaking of total lepton number, in the framework of the so-called Inverse seesaw mechanism (ISS). The work described in the thesis addresses the role of these sterile states in providing a satisfactory explanation to 3 open observational problems of the SM: the generation of neutrino masses and mixings, a viable dark matter candidate, and the dynamical generation of the baryon asymmetry of the Universe. We identified the minimal ISS realisation accounting for the observed neutrino data while at the same time complying with all available experimental and observational constraints. This study was based on a perturbative approach to the diagonalization of the neutrino mass matrix, which allowed to identify the number of states associated with the different mass scales. Our study revealed that, depending on the number of additional sterile fermion fields, the ISS can accommodate both a 3-flavour mixing scheme and a 3+more mixing scheme. The potential role of these sterile states as dark matter (DM) candidates led us to carry a dedicated study of the viability of the sterile fermion dark matter hypothesis in a minimal ISS realisation (in which the SM is extended by 2 right-handed neutrinos and 3 additional sterile fermion fields). The degeneracy in the sterile neutrino mass spectrum - which is characteristic of low scale seesaw models with approximate lepton number conservation - can play a relevant role in cosmology, since it allows us to explain the observed baryon asymmetry of the Universe via lepto-genesis. We identified different lepton number

  6. [Medico-legal risks of human voluntary sterilization].

    Science.gov (United States)

    Le Quinquis, P; Chevrant-Breton, O

    1986-01-01

    There has been no legislation in France explicitly authorizing voluntary sterilization, so that a practitioner carrying out a voluntary surgical sterilization runs a theoretical risk of lawsuit. Concern about the legal status of voluntary sterilization stems from 2 articles in the French penal code, article 16 which forbids the crime of castration, defined as the intentional complete and definitive amputation or removal of an organ necessary for procreation; and article 309 which forbids voluntary assault and battery resulting in death or inability to work for 8 days, or a lesser incapacity if the violence was premeditated. Vasectomy and tubal ligation differ from castration in that they do not involve removal or mutilation of the genital organs. Article 309 has been applied to a sterilization case only once. The criminal chamber of the Court of Cassation, France's highest appeals court, ruled in 1937 that the consent of the victim had no effect on penal responsibility, since individuals have no right to violate on their own persons the rules of public order by undergoing corporal injuries unjustified by medical need. There has been no penal judgment since 1937 in a voluntary sterilization case. In a 1983 judgment, the Court of Cassation upheld the responsibility of a surgeon for not informing a 28-year-old mother of 5 of the possibility of failure of the sterilization operation he performed on her. The patient found herself pregnant once again less than 1 month after the operation. Had she been informed of the possibility of pregnancy, she might have taken further precautions to avoid it. The court established a causal link between the problems created by the pregnancy and the fault of the physician in not providing adequate information. The court's decision was of interest because it included tubal ligation among surgical interventions condoned by the common law of medical responsibility, thereby implying acceptance of voluntary sterilization. The plaintiff

  7. Economical aspects of radiation sterilization with electron beam

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.

    1998-01-01

    Radiation sterilization has been introduced in Poland in the early seventies. Since then continuous progress is observed in quantity of sterilized products. The commercial irradiation facility was built in 1993 to fulfill growing demands for radiation service. The real costs of running this plant were shown. The share of the cost of investment and the cost of maintenance and spare parts in accelerator exploitation, as well as the cost of one hour accelerator exploitation against time of one year accelerator exploitation were taken into account

  8. Sterilization of sera and vaccines by cobalt gamma radiation

    International Nuclear Information System (INIS)

    Guidolin, R.; Morais, J.F.; Higashi, H.G.; Correa, A.; Cicarelli, R.M.B.; Previde, E.

    1988-01-01

    Diphtheria, tetanus, anti-snake venom sera and Diphtheria-Pertussis-Tetanus vaccine were submitted to different intensities of gamma radiation, in order to: verify the resistance of their specific activities to the action of gamma rays; evaluate the possibility of using this type of energy to sterilize some heterogeneous hyper immune sera and vaccines commonly utilized in Public Health. The results, according to the range employed, show the possibility of sterilizing the products tested, without any alteration to specific biological and chemical properties. (author)

  9. Revision of the ISO and EN radiation sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.; Hansen, J.

    2002-01-01

    The radiation sterilization standards, ISO 11137 and EN 552, are now being revised under "ISO lead", with the aim of producing only one international standard, although in four parts: (1) requirements. (2) dose-setting methods, (3) dose-substantiation methods and (4) dosimetry. Several aspects...... of the old standards that have caused problems, when they were used in practice, are addressed in the revision. Input from users of the standards is necessary in order that the standards be developed as useful tools in the documentation of radiation sterilization. (C) 2002 Elsevier Science Ltd. All rights...

  10. Studies of irradiation sterilization for single infusion device

    International Nuclear Information System (INIS)

    Chen Ruyan; Wang Keqin; Lu Zongmeng; Xiao Fenyuan; Xie Meizhi

    1988-05-01

    In practice of irradiation sterilization for single infusion device, object bacteria were selected and then their radiosensitivity were tested on the basis of practical production and irradiation environment. In view of the cylinder source and the static irradiation form, the dose rate of irradiation field and the dose distribution and uniformity in product box were measured in order to control sterilization quality. Through the measurements of material properties for irradiated infusion device and the test of causing rabbit fever as well as the survey of clinical practice, it was verified that the irradiation apparatus, the irradiation process and the product material etc. can satisfy the demands of sterilixzation and praction

  11. Ar + NO microwave plasmas for Escherichia coli sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Hueso, Jose L; Rico, Victor J; Cotrino, Jose; Gonzalez-Elipe, Agustin R [Instituto de Ciencia de Materiales de Sevilla, Centro Mixto CSIC-Universidad de Sevilla, Centro de Investigaciones Cientificas Isla de la Cartuja, Avda. Americo Vespucio 49, 41092 Sevilla (Spain); Frias, Jose E [Instituto de BioquImica Vegetal y FotosIntesis (IBVF-CSIC). Centro de Investigaciones CientIficas Isla de la Cartuja. Avda Americo Vespucio, 49, 41092 Sevilla (Spain)], E-mail: jhueso@icmse.csic.es

    2008-05-07

    Ar + NO microwave discharges are used for sterilization and the results are compared with additional experiments with Ar, O{sub 2} and N{sub 2}-O{sub 2} plasma mixtures. The NO{sup *} species produced in the Ar-NO mixtures remain up to long distances from the source, thus improving the sterilization efficiency of the process. E. coli individuals exposed to the Ar + NO plasma undergo morphological damage and cell lysis. Combined effects of etching (by O{sup *} and Ar{sup *} species) and UV radiation (from deactivation of NO{sup *} species) are responsible for the higher activity found for this plasma mixture. (fast track communication)

  12. Bringing men to the table: sterilization can be for him or for her.

    Science.gov (United States)

    Shih, Grace; Zhang, Ying; Bukowski, Kyle; Chen, Angela

    2014-12-01

    Sterilization, male and female combined, is the most common use of contraception in the United States. Despite the lower risk, higher cost-efficacy, and high efficacy of vasectomy compared with female sterilization, more US women rely on female sterilization than male sterilization. Reasons for low use of vasectomy include lack of knowledge and misconceptions about the procedure, lack of access, provider bias, and patient preferences. This article will provide a basic overview of male and female sterilization, an exploration of vasectomy barriers, and ways obstetrician-gynecologists can increase vasectomy uptake including regular recommendation of vasectomy to patients in long-term committed relationships considering sterilization.

  13. Contraception or eugenics? Sterilization and "mental retardation" in the 1970s and 1980s.

    Science.gov (United States)

    Ladd-Taylor, Molly

    2014-01-01

    Nonconsensual sterilization is usually seen as the by-product of a classist and racist society; disability is ignored. This article examines the 1973 sterilization of two young black girls from Alabama and other precedent-setting court cases involving the sterilization of "mentally retarded" white women to make disability more central to the historical analysis of sterilization. It analyzes the concept of mental retardation and the appeal of a surgical solution to birth control, assesses judicial deliberations over the "right to choose" contraceptive sterilization when the capacity to consent is in doubt, and reflects on the shadow of eugenics that hung over the sterilization debate in the 1970s and 1980s.

  14. Study on the radiation sterile mechanism of China mulberry wild silkworm (Bombyx mandorina Moore)

    International Nuclear Information System (INIS)

    Yang Rongxin; Xia Darong; Gu Weiping; Meng Zhiqi; Weng Hongbiao

    2000-01-01

    The sterile mechanism of China mulberry wild silkworm (Bombyx mandorina Moore) was studied on the chromosome structure variation by means of 60 Co γ-rays irradiation of the pupae. The dose of sub-sterilization for the wild silkworm was 250 Gy, under which the females of present generation were whole sterilized and the males were sub-sterilized. The chromosome structure variation such as deficiency and inversion of larva reproductive cells could be obviously observed. Most of cells with the abnormal chromosomes were sterilized, which was the main reason or radiation sterilization of Bombyx mandorina Moore

  15. Searching for a strategy to gamma-sterilize Portuguese cork stoppers - preliminary studies on bioburden, radioresistance and sterility assurance level

    International Nuclear Information System (INIS)

    Botelho, M.L.; Almeida-Vara, E.; Andrade, M.E.; Tenreiro, R.

    1988-01-01

    A gamma radiation plant will start running next year in Portugal, to sterilize medical devices and wine cork stoppers. As Portugal is the first world producer, manufacturer and exporter of wine cork stoppers, an efficient sterilizing procedure is required to overcome moulding from long term shipping. Preliminary research on cork stoppers bioburden and microflora radioresistance allowed to establish reliable D 10 and Sterility Assurance Level (SAL) values. Studied samples showed an initial average contamination of about 10 4 c.f.u. per cork stopper. The determined D 10 values for fungi were not higher than 2 kGy. In these conditions, a SAL of 10 -4 can be expected when the product is treated at a minimum absorbed dose of 15 kGy. (author)

  16. Analiza porównawcza wyników badania oczopląsu w teście kalorycznym uzyskanych przy użyciu metody ENG i VNG u osób zdrowych

    Directory of Open Access Journals (Sweden)

    Renata Pepaś

    2010-03-01

    Full Text Available Wprowadzenie: Najważniejszą obiektywną metodą oceny zaburzeń układu równowagi jest badanie oczopląsu. Badanie kaloryczne jako jedyny test obrazuje pobudliwość poszczególnych błędników, umożliwiając ocenę każdego z nich osobno. Cel pracy: Celem pracy jest analiza porównawcza wyników badania oczopląsu kalorycznego uzyskanych przy użyciu metody ENG i VNG u osób zdrowych. Materiał i metody: Badaniami objęto grupę 20 osób zdrowych, w tym 10 kobiet i 10 mężczyzn w wieku 22-26 lat. U wszystkich chorych przeprowadzono badanie podmiotowe oraz badanie przedmiotowe otoneurologiczne, badanie ENG i w odstępie 7-dniowym badanie VNG z kalibracją, oceną oczopląsu samoistnego oraz próbami kalorycznymi wg Hallpike’a. Test kaloryczny wykonano kalorymetrem powietrznym firmy HOMOTH, używając temperatury powietrza 30°C oraz 44°C, podawanych przez 40 s do ucha. Wyniki: W teście kalorycznym u żadnej osoby nie stwierdzono deficytu kanałowego wykraczającego poza granice przyjętych norm. Zaobserwowano niższe wartości średnie maksymalnej prędkości wolnej fazy oczopląsów w badaniu ENG niż VNG. Ponadto badanie VNG dodatkowo umożliwiło wyznaczenie wartości przewagi kierunkowej bezwzględnej oraz średniej pobudliwości błędników. Wnioski: Uzyskane wyniki wskazują, iż badanie VNG w stosunku do badania ENG jest bardziej precyzyjne i umożliwia dokładniejsze opisanie próby kalorycznej wg Hallpike’a. W badaniu VNG analiza parametru przewagi kierunkowej bezwzględnej znacznie podnosi wartość próby kalorycznej wg Hallpike’a.

  17. Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test.

    Science.gov (United States)

    Freitas, Raphael Ribeiro de Aquino; Tardelli, Maria Angela

    2016-05-24

    To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. G1 and G2 showed no bacterial growth when compared to conventional groups (pcontamination of the anesthetic solution. Comparar a esterilidade e a carga microbiana (bactérias e fungos) da parte externa dos frascos de envasamento de bupivacaína hiperbárica (Neocaína®) em ampola e bupivacaína em frasco-ampola das apresentações convencional e estéril (sterile pack). As apresentações estéreis (sterile pack) foram distribuídas em dois grupos, sendo que o G1 (n=16) continha as ampolas e o G2 (n=16), os frascos-ampola. As apresentações convencionais foram distribuídas em dois grupos, a saber G3 (n=16) com as ampolas e G4 (n=16) com os frascos-ampola. As ampolas e os frascos-ampolas eram abertos e tinham seu conteúdo aspirado. Os frascos vazios eram, então, acondicionados em sacos plásticos estéreis e enviados para análise quanto à carga microbiana (bactérias e fungos), bem como para o teste de esterilidade. Os dados foram analisados por meio do teste χ2 com correção Yates com intervalo de confiança de 95%. Os grupos G1 e G2 não apresentaram crescimento bacteriano quando comparado aos grupos convencionais (p<0,001). O microbiano mais comum nas amostras convencionais foi o Staphylococcus aureus. Não houve crescimento de fungos em nenhum dos grupos. O

  18. Effect of delayed sterilization on the production of intravenous fluids ...

    African Journals Online (AJOL)

    % (w/v) dextrose solution was studied. The 5% (w/v) dextrose was prepared with distilled water. The solution was inoculated with a laboratory isolate of Escherichia coli and thereafter divided into two: Solutions A and B. Sample A was sterilized ...

  19. Preservation and sterilization methods of the meniscal allografts: literature review.

    Science.gov (United States)

    Mickiewicz, Patrycja; Binkowski, Marcin; Bursig, Henryk; Wróbel, Zygmunt

    2014-09-01

    Nowadays, there are four types of meniscal allografts known: fresh, cryopreserved, deep-frozen and lyophilized ones but only two of them are widely used in clinical practice. Use of different types of meniscal allografts still remains controversial due to preparation method, their biomechanical properties as well as cost which is connected with processing and storage. The main aim of this review is to present the current status of knowledge concerning meniscal allograft preservation and sterilization, especially the advantages and disadvantages of each method. Authors wanted to show a broad spectrum of methods used and conceptions presented by other authors. The second aim is to gather available information about meniscal preservation and sterilization methods in one paper. Deep-frozen and cryopreserved meniscal allografts are the most frequently used ones in the clinical practice. The use of fresh grafts stays controversial but also has many followers. Lyophilized grafts in turn are not applied at present due to some serious drawbacks including reduction of tensile strength, poor rehydration, graft shrinkage and post-transplantation joint effusion as well as increased risk of meniscal size reduction. An application of sterilizing agents make the meniscal allograft free from the bacteria and viruses, but also it may cause serious structure changes. Therefore, choosing just one ideal method of meniscal allograft preservation and sterilization is complicated and should be based on broad knowledge and experience of surgeon performing the transplantation.

  20. Characterization of Prdm9 in equids and sterility in mules.

    Directory of Open Access Journals (Sweden)

    Cynthia C Steiner

    Full Text Available Prdm9 (Meisetz is the first speciation gene discovered in vertebrates conferring reproductive isolation. This locus encodes a meiosis-specific histone H3 methyltransferase that specifies meiotic recombination hotspots during gametogenesis. Allelic differences in Prdm9, characterized for a variable number of zinc finger (ZF domains, have been associated with hybrid sterility in male house mice via spermatogenic failure at the pachytene stage. The mule, a classic example of hybrid sterility in mammals also exhibits a similar spermatogenesis breakdown, making Prdm9 an interesting candidate to evaluate in equine hybrids. In this study, we characterized the Prdm9 gene in all species of equids by analyzing sequence variation of the ZF domains and estimating positive selection. We also evaluated the role of Prdm9 in hybrid sterility by assessing allelic differences of ZF domains in equine hybrids. We found remarkable variation in the sequence and number of ZF domains among equid species, ranging from five domains in the Tibetan kiang and Asiatic wild ass, to 14 in the Grevy's zebra. Positive selection was detected in all species at amino acid sites known to be associated with DNA-binding specificity of ZF domains in mice and humans. Equine hybrids, in particular a quartet pedigree composed of a fertile mule showed a mosaic of sequences and number of ZF domains suggesting that Prdm9 variation does not seem by itself to contribute to equine hybrid sterility.

  1. Sterilization effects on tensile strength of non-conventional suture ...

    African Journals Online (AJOL)

    An experiment was carried out to determine the tensile strength of embroidery, braiding, cobbler's thread and nylon mono-filament fishing line (NMFL) use as non-conventional suture material. Their tensile strength were determined pre- sterilization using various calibrated weights (50gm, 100gm, 500gm).

  2. Evaluation of disposable medical device packaging materials under ozone sterilization

    Directory of Open Access Journals (Sweden)

    Gerson Roberto Luqueta

    Full Text Available Abstract Introduction Ozonization is an alternative sterilization process for heat-sensitive medical devices. However, the side effects of this process on packaging materials should be verified. Methods Four types of commercial disposable packaging for medical devices were evaluated after undergoing ozone sterilization: crepe paper sheet, non-woven fabric sheet (SMS, medical grade paper-plastic pouch and Tyvec©-plastic pouch. For each material, the gas penetration through the microbiological barrier was measured. Other packaging properties, such as chemical composition, color, tactile and mechanical resistance, were also evaluated after sterilization, by using characterization techniques, namely microbiological indicators, infrared spectroscopy, tensile test and optical microscopy. Results All commercial disposable packaging showed good ozone penetration. Crepe paper and SMS were chemically and mechanically modified by ozone, while Tyvec© only suffered mechanical modification. Paper-plastic pouch was the packaging material which just experienced an acceptable reduction in tensile resistance, showing no variations on chemical or visual properties. Conclusion The results suggest that medical grade paper-plastic pouch is the most appropriate disposable medical device packaging to be sterilized by ozone when compared to other materials.

  3. The Shelf Life Estimation of Cold Sterilized Coconut Water

    Directory of Open Access Journals (Sweden)

    Sari Intan Kailaku

    2017-07-01

    Full Text Available Coconut water is well known due to its nutrient contents. Unfortunately, the  properties such as flavor, aroma, and taste is easily altered, soon after it is extracted from the fruit by splitting the fruit in two and collecting the water in a clean container. The shelf-life of coconut water drink can be improved by eliminating the enzyme that causes the degredation of the quality, i.e. polyphenol oxidase and peroxidase enzyme. Heat treatment such as pasteurization and Ultra Heat Treatment may inhibit the growth of these enzymes although resulted in the loss of coconut water unique and desirable properties. Ultrafiltration membrane and ultraviolet are two potential cold-sterilization methods. The objective of this research was to estimate the shelf-life of coconut water after ultrafiltration membrane and ultraviolet sterilization. Cold-sterilized coconut water was stored at three temperatures, i.e. 8, 13 and 25 °C, using polyethylene bottles in individual sizes (250 ml. The shelf-life was estimated using Accelerated Storage Study method with Arrhenius equation. pH and total sugar contents were measured as critical parameters, and total plate count was also observed. This research concludee that the shelf-life of coconut water which cold sterilized without any food additives was etimated to be 15 days at 25 °C.

  4. Optimization of explants surface sterilization condition for field grown ...

    African Journals Online (AJOL)

    The aim of this work was to sterilize nodal explants, so as to mitigate microbial contamination in peach micropropagation. The nodal explants were treated with three concentrations levels (0.15, 0.25 and 0.5% (w/v) active ingredient of chlorine) of locally produced bleach, sodium hypochlorite (NaOCl) for varying exposure ...

  5. Spacecraft Sterilization Using Non-Equilibrium Atmospheric Pressure Plasma

    Science.gov (United States)

    Cooper, Moogega; Vaze, Nachiket; Anderson, Shawn; Fridman, Gregory; Vasilets, Victor N.; Gutsol, Alexander; Tsapin, Alexander; Fridman, Alexander

    2007-01-01

    As a solution to chemically and thermally destructive sterilization methods currently used for spacecraft, non-equilibrium atmospheric pressure plasmas are used to treat surfaces inoculated with Bacillus subtilis and Deinococcus radiodurans. Evidence of significant morphological changes and reduction in viability due to plasma exposure will be presented, including a 4-log reduction of B. subtilis after 2 minutes of dielectric barrier discharge treatment.

  6. The Drosophila bipectinata species complex: degree of sterility and ...

    Indian Academy of Sciences (India)

    Haldane (1922) said that, in general, when one sex of hybrids between species is sterile or inviable, it is more frequently the heterogametic one. As suggested by numerous workers, the reason behind this phenomenon is attributed to the X chromosome, which occurs in hemizygous condition in the heterogametic sex.

  7. Sound pressure and temperature centering of material and sterilization

    Directory of Open Access Journals (Sweden)

    Klessiane Mendes de Fontes

    2017-06-01

    Full Text Available Objective: Gauge the sound pressure and temperature levels emitted by the equipment of the drying and sterilization rooms of the Material and Sterilization Center and compare them with the current legislation. Method: It is an experimental study with a quantitative approach, implemented in a school hospital in Joao Pessoa-PB. The data were obtained by a sound pressure meter and a thermal stress meter in September 2016. Results and Discussion: The data evidenced high sound pressure levels, reaching a mean of 71.25 and 76.25 dB (A, in the drying and sterilization rooms respectively. The levels found do not exceed that recommended by NR15 (Regulatory Norm 15 which is 85dB(A, but NBR 10152/87 (Brazilian Norm 10152/87 indicates levels between 45 and 55 dB(A for acoustic well-being. As for the temperature the measured mean ranged between 24.91 and 25.87 °C. Conclusion: The levels of sound pressure and temperatures found in the environment can cause physiopsychological changes in the professionals that works in this services. Keywords: Sound pressure; Temperature; Material and Sterilization Center

  8. Sterile neutrinos with secret interactions — lasting friendship with cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Xiaoyong [International Center for Theoretical Physics,Strada Costiera 11, Trieste, 34014 (Italy); Dasgupta, Basudeb [Tata Institute of Fundamental Research,Homi Bhabha Road, Mumbai, 400005 (India); Kopp, Joachim [PRISMA Cluster of Excellence and Mainz Institute for Theoretical Physics,Johannes Gutenberg University, Staudingerweg 7, Mainz, 55128 (Germany)

    2015-10-06

    Sterile neutrinos with mass ≃1 eV and order 10% mixing with active neutrinos have been proposed as a solution to anomalies in neutrino oscillation data, but are tightly constrained by cosmological limits. It was recently shown that these constraints are avoided if sterile neutrinos couple to a new MeV-scale gauge boson A{sup ′}. However, even this scenario is restricted by structure formation constraints when A{sup ′}-mediated collisional processes lead to efficient active-to-sterile neutrino conversion after neutrinos have decoupled. In view of this, we reevaluate in this paper the viability of sterile neutrinos with such “secret” interactions. We carefully dissect their evolution in the early Universe, including the various production channels and the expected modifications to large scale structure formation. We argue that there are two regions in parameter space — one at very small A{sup ′} coupling, one at relatively large A{sup ′} coupling — where all constraints from big bang nucleosynthesis (BBN), cosmic microwave background (CMB), and large scale structure (LSS) data are satisfied. Interestingly, the large A{sup ′} coupling region is precisely the region that was previously shown to have potentially important consequences for the small scale structure of dark matter halos if the A{sup ′} boson couples also to the dark matter in the Universe.

  9. Assessing genetic variability in male sterile and low fertile citrus ...

    African Journals Online (AJOL)

    Yomi

    2012-01-24

    Jan 24, 2012 ... male sterile types, with old scattered resources; Iran has obvious diversity of citrus materials. ..... sexual reproduction and recombination are disabled in detecting such mutations in asexually propagated species. Therefore, it seems that in plants with asexual propagation system, inclusion of dominant ...

  10. Restrictions on the lifetime of sterile neutrinos from primordial nucleosynthesis

    CERN Document Server

    Ruchayskiy, Oleg

    2012-01-01

    We analyze the influence of decaying sterile neutrinos with the masses in the range 1-140 MeV on the primordial Helium-4 abundance, explicitly solving the Boltzmann equations for all particle species, taking into account neutrino flavour oscillations, and paying special attention to systematic uncertainties. We show that the Helium abundance depends only on the sterile neutrino lifetime and not on the way the active-sterile mixing is distributed between flavours, and derive an upper bound on the lifetime. We also demonstrate that the recent results of Izotov & Thuan [arXiv:1001.4440], who find 2sigma higher than predicted by the standard primordial nucleosynthesis value of Helium-4 abundance, are consistent with the presence in the plasma of sterile neutrinos with the lifetime 0.01-2 seconds. The decay of these particles perturbs the spectra of (decoupled) neutrinos and heats photons, changing the ratio of neutrino to photon energy density, that can be interpreted as extra neutrino species at the recombin...

  11. Measuring growth index in a Universe with sterile neutrinos

    Directory of Open Access Journals (Sweden)

    Jing-Fei Zhang

    2014-12-01

    Full Text Available Consistency tests for the general relativity (GR can be performed by constraining the growth index γ using the measurements of redshift-space distortions (RSD in conjunction with other observations. In previous studies, deviations from the GR expected value of γ≈0.55 at the 2–3σ level were found. In this work, we reconsider the measurement of γ in a Universe with sterile neutrinos. We constrain the sterile neutrino cosmological model using the RSD measurements combined with the cosmic microwave background data (Planck temperature data plus WMAP 9-yr polarization data, the baryon acoustic oscillation data, the Hubble constant direct measurement, the Planck Sunyaev–Zeldovich cluster counts data, and the galaxy shear data. We obtain the constraint result of the growth index, γ=0.584−0.048+0.047, well consistent with the GR expected value (the consistency is at the 0.6σ level. For the parameters of sterile neutrino, we obtain Neff=3.62−0.42+0.26 and mν,sterileeff=0.48−0.14+0.11 eV. We also consider the BICEP2 data and perform an analysis on the model with tensor modes. Similar fit results are obtained, showing that once light sterile neutrino is considered in the Universe, GR will become well consistent with the current observations.

  12. Microbial Evaluation of Some Non-sterile Pharmaceutical ...

    African Journals Online (AJOL)

    Purpose: To determine the type and incidence of predominant microorganisms in certain non-sterile pharmaceuticals immediately after collection and one year later. Methods: All pharmaceutical samples were subjected to the following examinations: total bacterial count and presence of microbial pathogens, using ...

  13. [Characteristics and follow-up of sterilized women].

    Science.gov (United States)

    Molina, R; López, I

    1982-02-01

    In order to gain insight into the characteristics of sterilized women evaluating at the same time the effects of sterilization, 70 patients who underwent sterilization in an Obstetrics Unit were studied. The clinical records were analyzed and a questionnaire comprising general knowledge, attitudes, and conduct was applied. Women over 30 and with a parity of 4 or more predominated. There was a low frequency of abortions reported but this information is not reliable. The educational level was lower than the average for the Metropolitan Region and pointed to a more precocious initiation in sexual relationships than was found in a previous similar study. Religion proved to be no obstacle for sterilization nor was attendance to church subsequently diminished. A negative moral feeling towards the operation nearly disappeared following surgery. The fear of sexual dissatisfaction in husbands decreased following surgery and a similar effect was seen with regard to negative self-image. There were no changes in marital relations nor in their satisfaction. (author's modified)

  14. Comparison of Sterile and Clean Dressing Techniques in Post ...

    African Journals Online (AJOL)

    Chinese hospital, and to compare their impact on wound healing and the cost of the dressing materials with respect to postoperative .... The mean age of the control group patients who received sterile dressings was 38.9 years, and that of those who received clean dressings was 42.2 years. The two types of dressing ...

  15. Radio-sterilization effects on adult males of Glossina tachinoides ...

    African Journals Online (AJOL)

    Induced sterility of adult males of Glossina tachiniodes irradiated with gamma doses of 130, 150 and 160 Gy, respectively, in air was investigated. The flies were irradiated at horizontal distances of 50 cm and 70 cm, respectively from the Gamma Facility. The mean percentage insemination of spermathecae ranged between ...

  16. Surface sterilization and duration of seed storage influenced ...

    African Journals Online (AJOL)

    The effects of factorial combinations of four storage duration (in days after seed extraction) and surface sterilization with three dilution levels of sodium hypochlorite on seedling emergence and seedling quality of African breadfruit were studied. Storage duration significantly influenced days to seedling emergence, ...

  17. Microbicidal effectiveness of X-rays used for sterilization purposes

    DEFF Research Database (Denmark)

    Tallentire, Alan; Miller, Arne

    2015-01-01

    The radiation response of spores of Bacillus pumilus was examined for irradiation with 5–7 MeV X-ray at commercial sterilization facilities. The response was found to be the same as that for irradiation with cobalt 60 photons, 10 MeV electrons and low energy electrons at 100 and 80 keV....

  18. Field dosimetry on sterilization area of medical-hospitable materials

    International Nuclear Information System (INIS)

    Mariano, C.S.T.P.; Campos, L.L.

    1992-01-01

    The calcium sulfate doped with dysprosium, used in high dose dosimetry by electron paramagnetic resonance (EPR), is studied on field dosimetry for medical-hospitable materials sterilization. The calibration curves of EPR signal in function of absorbed dose in air and the thermal decay of EPR signal at room temperature are also presented. (C.G.C)

  19. Surgical sterilization of the African giant pouched rats | Werema ...

    African Journals Online (AJOL)

    ... to all principles of surgery. This study has demonstrated the three surgical procedures for African Giant pouched rats as being useful to veterinarians in public/private practice and/or in biomedical research facilities. Keywords: Surgical sterilization, ovariectomy, ovariohysterectomy, orchidectomy, African giant pouched rats ...

  20. Evaluation of radiation-sterilized bone in clinical use

    International Nuclear Information System (INIS)

    Komender, J.

    1978-01-01

    The clinical results of preserved bone transplantation are presented. Analysis is based on the activity of the Central Tissue Bank at Warsaw. Radiation sterilization of grafts is a routine method used in this Bank. The clinical evaluation of biostatic bone grafts is discussed. (author)

  1. Strawberry sterility - what is the causal agent(s)?

    Czech Academy of Sciences Publication Activity Database

    Fránová, Jana; Petrzik, Karel

    2008-01-01

    Roč. 780, - (2008), s. 27-34 ISSN 0567-7572 R&D Projects: GA AV ČR(CZ) 1QS500510558 Institutional research plan: CEZ:AV0Z50510513 Keywords : plant pathology * strawberry sterility Subject RIV: EE - Microbiology, Virology

  2. Non-surgical methods of contraception and sterilization.

    Science.gov (United States)

    Kutzler, Michelle; Wood, Anna

    2006-08-01

    The Humane Society of the United States estimates that each year between 8 and 10 million dogs and cats enter shelters and 4-5 million of these animals are euthanized due to lack of homes. Many veterinarians within the United States recommend surgical sterilization for population control in dogs and cats. However, there are non-surgical methods to control reproduction. Pharmacologic methods of contraception and sterilization can be safe, reliable and reversible. Hormonal treatments using progestins, androgens, or gonadotropin releasing hormone (GnRH) analogs act to either directly block reproductive hormone receptor-mediated events, or indirectly block conception via negative feedback mechanisms. Immunocontraception, via vaccination against GnRH, the luteinizing hormone receptor or zona pellucida proteins, is also possible. Intratesticular or intraepididymal injections provide a method for non-surgical sterilization of the male dog and cat. Additional methods have been employed for mechanical disruption of fertility including intravaginal and intrauterine devices and ultrasound testicular ablation. Alternative approaches to surgical sterilization will be reviewed.

  3. Influence of heat sterilization on the organoleptic quality of spices

    NARCIS (Netherlands)

    Maarse, H.; Nijssen, L.M.; Nowak, M.

    1982-01-01

    Heat sterilization and storage of food products containing spices often results in a change of their organoleptic quality. Our knowledge about the stability of individual spices, however, is low. Therefore the heat stability of 8 different spices most frequently used has been investigated: cinnamon,

  4. Medical hospital materials processing: a literature review on sterilization effectiveness

    Directory of Open Access Journals (Sweden)

    Leonardo Mousinho Guerra

    2013-04-01

    Full Text Available Backgound and Objectives: Surgical instruments are widely reprocessed, mainly in developing countries, where the cost of using these materials is high. Scientifi c literature indicates the absence of validated cleaning and sterilization processes. The study aimed at evaluating, through a literature review, the evidence to support or not the practice of reprocessing and reuse of originally single-use, medical-hospital materials. Methods: A total of 27 articles in English and Portuguese were selected from journals indexed in the LILACS, Pubmed and Medline databases, as well as studies published in ScienceDirect website using the following key words: sterilization, single-use articles, hospital infection and surgical instruments. Articles that did not fi t the study subject were excluded. Results: There was a great variety of studied instruments and reprocessing methods. Most articles emphasize the sterilization ineffectiveness, identifying microorganisms at the end of the process. Conclusion: Based on the current knowledge, it is important to consider each case validating surgical materials reprocessing and reuse protocols based on scientific knowledge. Based on the analysis of the study articles, we concluded that this practice cannot be performed indiscriminately. KEYWORDS: Sterilization. Cross infection. Surgical Equipment. Public Health.

  5. PGH Training Centers helps institutionalize surgical sterilization in Philippine program.

    Science.gov (United States)

    1979-01-01

    The Philippine Study and Training Center for Surgical Sterilization (STCSS) was established in August 1974 under the auspices of the Philippine General Hospital and the University of the Philippines College of Medicine to institutionalize surgical sterilization in the medical schools and family planning organizations. The success of the program is documented by the increase in acceptors from 1400 in 1974 to 49,000 in 1976 and from the increase in sterilization centers from 50 when the program began to 165 in 1975. Approximately 300 doctors have completed the program which provides a variety of procedures to the public. Follow-up evaluation trips made by the program staff members to program graduates allow the program to benefit from feedback on conditions under which the graduates work and thus to keep its content realistic and practical. Such visits also revealed the need to train not only a physician but also his or her support staff, and courses to this effect are currently being planned. This national training center is closely allied with the Philippine Sterilization Certifying Board and engages in a variety of research activities. Research findings and training materials have been published in 2 manuals.

  6. Radiation sterilization of medical products in the Philippines

    Science.gov (United States)

    Singson, C.; Carmona, C.; de Guzman, Z.; Barrun, W.; Lanuza, L.

    This paper presents the results of a comprehensive investigation of the biological, microbiological, physico-chemical, and dosimetry aspects of using gamma irradiation for the sterilization of locally manufactured medical products and pharmaceuticals. The objective of this study is to determine the technological feasibility of radiation sterilization for the said products in the Philippines. Hence, the materials used were directly obtained from local manufacturers. They are polyvinyl chloride or polyethylene based medical plastic disposables namely: absorbent cotton, surgical gauze, bandage, visceral packs, and some antibiotics and opthalmic ointments. The gamma facility of the Philippine Atomic Energy Commission was used for the irradiation. Result of biological studies indicate no signs of toxicity on experimental mice injected with extracts from irradiated samples. The contaminants are identified as Pseudomonas Sp. Staphyloccocus Aureus and Bacillus Subtilis. The D 10 values of survivors of higher doses ranged below 0.235 Megarad suggesting that these contaminants can be eliminated by the generally used sterilizing dose of 2.5 Mrads. The physico-chemical tests did not indicate any significant degradation of the irradiated products. Opthalmic and topical antibiotic ointments showed no marked decrease in potency. Fading tests on dosimeters used showed that red perspex is a more efficient dosimeter than clear perspex when irradiation time is prolonged. These studies indicated that radiation sterilization is technically feasible for locally manufactured medical products.

  7. Feasibility of sterilizing traditional Chinese medicines by gamma-irradiation

    International Nuclear Information System (INIS)

    Fang Xingwang; Wu Jilan

    1998-01-01

    The feasibility of sterilizing traditional Chinese medicines (TCMs) by γ-irradiation has been systematically evaluated by the biological, toxicological and physicochemical tests on irradiated hundreds of TCMs. Those TCMs investigated in general show no significant biological or toxicological changes after irradiation, yet physicochemical changes are detectable in some irradiated TCMs, and water in TCMs enhances the effects. Those results obtained from radiolysis of some major effective components of TCMs in aqueous or ethanolic solutions reveal that the site selection of radiolytically generated radicals follows the example of simple compounds with same function groups. Wholesomeness and chemical clearance present a bright future to sterilizing TCMs by γ irradiation, however, some important measures and steps should be adopted: (1) The producers must strictly execute manufacturing procedure to reduce microbiological contamination thus lower the applied dose for sterilization which is recommended to be controlled under 5, 7 or 10 kGy for dry herb, 7 kGy for herbal medicine and 5 kGy for some special herbal medicine; (2) Herb to be sterilized by γ-irradiation should exist in possible dry state; (3) Powder TCMs is recommended to mix with honey forming bolus, which can minimize the decomposition of herb

  8. Sterile Particles from the Flavor Gauge Model of Masses

    Czech Academy of Sciences Publication Activity Database

    Smetana, Adam

    2013-01-01

    Roč. 2013, č. 4 (2013), s. 139 ISSN 1029-8479 R&D Projects: GA MŠk LA08015 Institutional support: RVO:61389005 Keywords : dynamical mass generation * flavor gauge symmetry * right-handed neutrino condensation * sterile neutrinos * majorons Subject RIV: BE - Theoretical Physics Impact factor: 6.220, year: 2013

  9. Search for heavy sterile neutrinos with SHiP

    CERN Document Server

    Jacobsson, Richard

    Invited contribution to the White Paper on keV sterile neutrino Dark Matter as proceedings of the v-Dark 2015 international workshop which was held at the Institute for Advanced Study of the Technical University of Munich, Garching, Germany, 7 - 9 December 2015. White Paper will be submitted to JCAP.

  10. Female sterilization: update on clinical efficacy, side effects and contraindications.

    Science.gov (United States)

    Gizzo, Salvatore; Bertocco, Anna; Saccardi, Carlo; Di Gangi, Stefania; Litta, Pietro Salvatore; D'antona, Donato; Nardelli, Giovanni Battista

    2014-10-01

    The aim of this review is to compare studies concerning female sterilization in order to define the most suitable approach and device for each patient considering timing, safety, cost-effectiveness, failure rate, complication rate and patient satisfaction. A systematic literature search was conducted in electronic databases MEDLINE-EMBASE-Sciencedirect and Cochrane Library between 2000 and 2012. All original descriptions, case reports, retrospective and review articles on tubal sterilization methods have been considered. Outcome measures were effectiveness, tolerability, procedure complications and female satisfaction. The ideal female sterilization system should be a simple, safe, highly efficient, easily learned, inexpensive, one-time procedure without negative side-effects. Nowadays, the trans-cervical approach is associated with minimal postoperative pain, allowing short hospitalization and fast resumption of daily activities. Laparoscopic and laparotomic approaches are considered second choices, since, particularly in developing countries, the transcervical hysteroscopic methods will increasingly spread within gynaecological clinical practice. Safety issues, hospital stay, costs and surgeons' experience are important factors in decision-making of the method for female sterilization. Hysteroscopic devices should be preferred when possible. The counselling time remains a fundamental step in choice. The decision concerning method depends on the setting, the surgeon's experience, the country's economical development and the woman's preference.

  11. The use of sterilized mosquito nets for hernioplasty

    DEFF Research Database (Denmark)

    Sørensen, C G; Rosenberg, J

    2012-01-01

    Hernia repair is among the most frequent surgeries performed. Surgeons prefer the tension-free mesh repair, but in large parts of the world, commercial meshes are unavailable or unaffordable. Consequently, surgeons have been experimenting with insertion of inexpensive non-commercial meshes, the m......, the most common being a non-impregnated, sterilized mosquito net....

  12. Principles of heat sterilization in dental practice | van Palenstein ...

    African Journals Online (AJOL)

    Principles of heat sterilization in dental practice. WH van Palenstein Helderman. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's ...

  13. Sterilization and Disinfection Practices in Selected Dental Clinics in ...

    African Journals Online (AJOL)

    To assess the sterilization and disinfection practices in selected dental clinics in Cameroon. The study conducted in the second half of 2009 included 41 dental clinics in 4 out of the 10 provinces in Cameroon. Questionnaire was used to obtain information about the ownership and location of the clinic, washing and packing ...

  14. Sterilization and disinfection in a private clinic | Rahim | Tanzania ...

    African Journals Online (AJOL)

    Sterilization and disinfection in a private clinic. MA Rahim. Abstract. No Abstract. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  15. Development and Validation of Sterility Systems for Trees

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, Steve; Shevchenko, Olga; Ma, Caiping (Cathleen)

    2007-03-30

    The overall goal of this project was to develop and validate sterility systems in poplar with the ultimate goal of fulfilling the basic requirements for commercial use. For this, sterility must be complete and stable over multiple growing seasons, cause no detrimental effects on vegetative growth, and successful transformation events must be identifiable via molecular tests when trees are still juvenile. Because of the inherent difficulties in achieving and demonstrating complete sterility in trees, our approach was to study alternate sterility systems in Arabidopsis and/or early-flowering tree systems. The public benefit from this work is the capacity for containment of genes or exotic forms of trees so they can be of benefit for industry for production of wood, energy, and renewable products, while having minimal impact on wild populations of trees. We tested three methods for engineering sterility: dominant negative mutant (DNM) proteins, floral tissue ablation, and RNA interference (RNAi) to suppress the expression of several floral regulatory genes. The ultimate goal of this work was to produce a number of transgenic poplars that could be outplanted to enable future assessments of the effectiveness of these transgenic sterility methods. Our attempts to produce ablation constructs that did not interfere with tree health were partially successful. Using the poplar LEAFY gene promoter and the barnase/barstar system, we were able to regenerate plants that grew well in the greenhouse, but they showed poor health in the field. Four of seven DNM genes tested were considered promising enough, based on results in Arabidopsis, to produce transgenic poplars. Single, double, and triple RNAi genes were produced and transformed into poplar. Over all, we produced 1,964 PCR-confirmed transgenic events with 19 different kinds of sterility genes and several kinds of control genes. We propagated 5,640, 6,820, and 7,055 trees for each of three test poplar genotypes, and field

  16. The rationale and a computer evaluation of a gamma irradiation sterilization dose determination method for medical devices using a substerilization incremental dose sterility test protocol.

    Science.gov (United States)

    Davis, K W; Strawderman, W E; Whitby, J L

    1984-08-01

    The experimental procedure described is designed to allow calculation of the radiation sterilization dose for medical devices to any desired standard of sterility assurance. The procedure makes use of the results of a series of sterility tests on device samples exposed to doses of radiation from 0.2 to 1.8 Mrad in 0.2 Mrad increments. From the sterility test data a 10(-2) sterility level dose is determined. A formula is described that allows a value called DS Mrad to be calculated. This is an estimate of the effective radiation resistance of the heterogeneous microbial population remaining in the tail portion of the inactivation curve at the 10(-2) dose and above. DS Mrad is used as a D10 value and is applied, in conjunction with the 10(-2) sterility level dose, to an extrapolation factor to estimate a sufficient radiation sterilization dose. A computer simulation of the substerilization process has been carried out. This has allowed an extensive evaluation of the procedure, and the sterilization dose obtained from calculation to be compared with the actual dose required. Good agreement was obtained with most microbial populations examined, but examples of both overdosing and underdosing were found with microbial populations containing a proportion of organisms displaying pronounced shoulder inactivation kinetics. The method allows the radiation sterilization dose to be derived from the natural resistance of the microbial population to gamma sterilization.

  17. FUNCTIONAL MALE STERILITY AND ITS USE IN BREEDING OF VEGETABLE AND MELON CROPS

    Directory of Open Access Journals (Sweden)

    A. N. Bocharnikov

    2014-01-01

    Full Text Available The article describes the manifestation of functional male sterility and its importance in the breeding of melons. Utilization of functional male sterility allows solving the problem effective hybrid seed production.

  18. Current systems of sterilization in the Philippines in both government and private hospitals

    International Nuclear Information System (INIS)

    Lim, L.E.

    1996-01-01

    In the Philippines, there are 1,700 registered hospitals, both private and government. There are 80,000 beds. The systems of sterilization are mainly using steam or to use ethylene oxide sterilization. Gamma ray sterilization is purely on experimental basis and very limited scale for industrial products. The author will trace the history of sterilization, practised since a century ago and trace back to the present system of sterilization. The principles applied, precautions and limitations or advantages of the different systems will be discussed particularly steam sterilization and ethylene oxide. Other forms of sterilization either chemical or physical will be discussed in passing. Experience in gamma ray sterilization in Japan and Australia will be presented when available data are obtained, to encourage local investors to engage in such venture. Philippines has been left behind by our neighbors. (author)

  19. Quarter of a century of female sterilization in Jos, Central Nigeria.

    Science.gov (United States)

    Mutihir, Josiah T; Nyango, D D

    2011-03-01

    The study was to assess the types and trend of female sterilization between January 1985 and December 2009 (25 years) in Jos, Central Nigeria. There were 25,313 new acceptors of modern contraceptive methods out of which 4,951 (19.6%) were female sterilizations. Minilaparotomy was the commonest method of female sterilization. Local anaesthesia was the commonest anaesthetic utilized. The women were mostly women of relatively older age, grandmultiparous and with large family size. The women were of mean of 38.4 years, and 60% had more than 5 children at the time of sterilization. Interval sterilization constituted 78.5% of the female sterilizations. The acceptance of female sterilization, however, has declined over the years, as acceptance of the long acting contraceptive implants increases. Female sterilization by minilaparotomy under local anaesthesia was found to be feasible, cost effective and acceptable by majority of clients, and recommended for integration into minor gynaecological procedures in our institutions.

  20. Effectiveness and feasibility of hysteroscopic sterilization techniques: a systematic review and meta-analysis

    NARCIS (Netherlands)

    la Chapelle, C.F.; Veersema, S.; Brölmann, H.A.M.; Jansen, F.W.

    2015-01-01

    Objective To assess whether hysteroscopic sterilization is feasible and effective in preventing pregnancy. Secondarily, to identify risk factors for failure of hysteroscopic sterilization. Design A systematic review and meta-analysis. Setting Not applicable. Patient(s) Women undergoing hysteroscopic

  1. Sterilization as last resort in women with intellectual disabilities: protection or disservice?

    Science.gov (United States)

    Insogna, Iris; Fiester, Autumn

    2015-01-01

    The legacy of the eugenics movement in the United States, including the involuntary sterilization of those deemed unfit to reproduce, has created a profound backlash against sterilization among certain populations. Particularly in treating women with intellectual disabilities, the field of obstetrics and gynecology has widely adopted an antisterilization stance. When treating women with intellectual disabilities, sterilization is generally considered a last resort. This essay revisits the issue of sterilization in women with intellectual disabilities, asking whether the field's stance of sterilization as a last resort is best viewed as a protection of this vulnerable population or one that actually does significant harm. We use a hypothetical but realistic patient case to examine the potential risks and benefits of sterilization. After reviewing the arguments against sterilization as a first-line treatment, we defend the controversial position that, in some cases, sterilization should be presented as an equally legitimate choice to reversible contraceptives. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Hysteroscopic sterilization: 10-year retrospective analysis of worldwide pregnancy reports.

    Science.gov (United States)

    Munro, M G; Nichols, J E; Levy, B; Vleugels, M P H; Veersema, S

    2014-01-01

    To identify factors that might contribute to pregnancies reported after hysteroscopic sterilization worldwide. Retrospective review of commercial data compiled from the MAUDE database, medical literature, and manufacturer reports received during commercial distribution of hysteroscopic sterilization micro-inserts from 2001 through 2010 (Canadian Taskforce classification III descriptive study). From 2001 through 2010, 497 305 hysteroscopic sterilization kits were distributed worldwide, and 748 pregnancies were reported, i.e., 0.15% of the estimated user population based on the number of distributed kits. The data were sufficient to enable analysis of 508 pregnancies for potential contributing factors and showed most to be associated with patient or physician noncompliance (n = 264) or misinterpreted confirmation tests (n = 212). Conceptions deemed to have occurred within 2 weeks of the procedure and therefore too early for detection were identified in 32 cases. Although there are limitations to the dataset and the study design is retrospective, it represents the largest body of cumulative hysteroscopic sterilization data available to date. Of the 748 pregnancies reported, it is apparent that some might have been prevented with greater patient and clinician attention to interim contraceptive use and counseling and with more rigorous evaluation and informed interpretation of the procedure confirmation tests. Although the estimated pregnancy rate based on such a dataset is likely an underestimation, it does suggest that the evaluable field performance of hysteroscopic sterilization micro-inserts is consistent with the labeled age-adjusted effectiveness of 99.74% at 5 years. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  3. Acute sterile endophthalmitis following intravitreal bevacizumab: case series

    Science.gov (United States)

    Orozco-Hernández, Axel; Ortega-Larrocea, Ximena; Sánchez-Bermúdez, Gustavo; García-Aguirre, Gerardo; Cantón, Virgilio Morales; Velez-Montoya, Raul

    2014-01-01

    Background Since the ophthalmological community adopted the use of intravitreal bevacizumab as an accepted off-label treatment for neovascular diseases, the amount of knowledge regarding its effects and properties has been increasing continually. In the last few years, there have been an increasing number of reports about sterile intraocular inflammation and intraocular pressure elevations after intravitreal bevacizumab. In the following case series, we describe the clinical presentation and outcomes of ten consecutive cases of patients developing mild-to-severe sterile intraocular inflammation after intravitreal bevacizumab and their management. Methods This report presents a retrospective case series. We reviewed the medical records of ten consecutive patients from a group of 46, in whom repackaged bevacizumab in individual aliquots from two vials from the same batch were used. All surgical procedures were performed using standard sterile techniques in the operating room. At each follow-up visit, patients underwent a complete ophthalmological examination including visual acuity assessment, intraocular pressure, biomicroscopy, and posterior fundus examination. Results Ten patients presented sterile endophthalmitis with an onset time of 3.5±1.95 days. The clinical characteristics were mild pain, slight visual loss, conjunctival hyperemia, and various degrees of intraocular inflammation with microhypopyon. All cultures were negative. All patients were managed with topical steroids and antibiotics, except two, in whom, due to severe vitreous cells, intravitreal antibiotics were used. Three patients showed a transient elevation of intraocular pressure. Only 50% of the patients regained a visual acuity equal or better to the baseline visual acuity on file. Conclusion The increasing number of intravitreal injections of bevacizumab applied every day, due to its widespread acceptance, might be one reason why the number of cases of sterile endophthalmitis is rising. Fast

  4. Dissecting the genetic architecture of F-1 hybrid sterility in house mice

    OpenAIRE

    Dzúr-Gejdošová, M. (Mária); Šimeček, P. (Petr); Gregorová, S. (Soňa); Bhattacharyya, T. (Tanmoy); Forejt, J. (Jiří)

    2012-01-01

    Hybrid sterility as a postzygotic reproductive isolation mechanism has been studied for over 80 years, yet the first identifications of hybrid sterility genes in Drosophila and mouse are quite recent. To study the genetic architecture of F-1 hybrid sterility between young subspecies of house mouse Mus m. domesticus and M. m. musculus, we conducted QTL analysis of a backcross between inbred strains representing these two subspecies and probed the role of individual chromosomes in hybrid steril...

  5. Evaluation of Effects of Sterilization on Mechanical Properties of Orthodontic Wires

    Directory of Open Access Journals (Sweden)

    Sridhar Kannan

    2012-01-01

    Results: Dry heat sterilization, autoclave, 2% glutaraldehyde solution had no effect on ultimate tensile strength, 0.1% yield strength, modulus of elasticity and percentage elongation of stainless steel and elgiloy wires. Tensile strength and yield strength of Nitinol and b-titanium wires together with percentage elongation of b-titanium wires significantly increased following dry heat sterilization and autoclave. No detrimental effects on properties of wires were observed. These sterilization procedures could be safely recommended for sterilization of orthodontic wires.

  6. Research progress on the effect of microwave sterilization on agricultural products quality

    Science.gov (United States)

    Zhu, Xiang-hao; Yang, Yu-xia; Duan, Zhen-hua

    2018-02-01

    Different sterilization methods have different effects on the quality of agricultural products, microwave sterilization inhibited or eliminated microorganism by the use of microwave thermal effects and non-thermal. In this paper, the effects of microwave sterilization on the quality of fruits and vegetables, dairy, meat, grain, aquatic products and other agricultural products were introduced, and the possible development trends of microwave sterilization in agricultural products processing application were put forward.

  7. Radiation Sterilization of Two Commonly Culture Media Used for Bacterial Growth

    International Nuclear Information System (INIS)

    El-Hifnawi, H.N.

    2008-01-01

    Radiation sterilization of culture media used for the cultivation of bacteria by Co-60 gamma ray was investigated. Nutrient agar and tryptone glucose yeast extract (TGY) media widely used for the propagation of bacteria were sterilized with 15 kGy dose gamma radiation. Seven different bacterial species were grown as well on the radiation sterilized media as on media sterilized by autoclaving in a conventional way

  8. IN VITRO CULTURE OF Sequoia sempervirens L. ON NUTRITIVE MEDIA STERILIZED WITH SODIUM HYPOCHLORITE

    OpenAIRE

    Juliana Martins Ribeiro; Silvio Lopes Teixeira; Débora Costa Bastos

    2011-01-01

    The autoclaving used for sterilization of glassware, culture media and surgical materials in laboratory is a costly operation, due to the high cost of the equipment and the equally high consumption of energy. For these reasons, the substitution of this sterilization technique for another less costly one, such as chemical sterilization, would be highly desirable. The present study aimed to compare the techniques of sterilization of plant tissue culture media with sodium hypochlorite and that o...

  9. Reproductive biology and induced sterility as determinants for genetic control of mosquitoes with the Sterile Insect Technique

    NARCIS (Netherlands)

    Helinski, M.

    2008-01-01

    Malaria remains an important health issue in sub-Saharan Africa, and new methods to reduce the disease are needed. In this thesis, the use of the Sterile Insect Technique (SIT) against the African malaria vector Anopheles arabiensis was explored. The SIT relies on the releases of large numbers of

  10. 21 CFR 522.380 - Chloral hydrate, pentobarbital, and magnesium sulfate sterile aqueous solution.

    Science.gov (United States)

    2010-04-01

    ... sulfate sterile aqueous solution. 522.380 Section 522.380 Food and Drugs FOOD AND DRUG ADMINISTRATION... sterile aqueous solution. (a) [Reserved] (b)(1) Specifications. Chloral hydrate, pentobarbital, and magnesium sulfate sterile aqueous solution contains 42.5 milligrams of chloral hydrate, 8.86 milligrams of...

  11. Sterilization by Gamma-Radiation of the Sodium Salt of p-Amino-Salicylic Acid

    International Nuclear Information System (INIS)

    Bellion, B.; Denti, E.; Massagli, A.

    1963-01-01

    Sodium p-amino-salicylate cannot be sterilized thermally. During manufacture or packing for medical purposes it must therefore be handled under sterilized conditions, with all the difficulties which this involves. The paper quotes experimental data to show that, using gamma irradiation, the product may be sterilized without damage and without the formation of substances harmful from the medical standpoint. (author) [fr

  12. Induced Sterility as a Factor in the Competition between Barley Varieties

    DEFF Research Database (Denmark)

    Sandfær, Jens

    1968-01-01

    In a mixture of two spring barley varieties, ‘Tystofte Prentice’ and ‘Svaløf Freja’, a sterility interaction was found. The percentage of sterile flowers in ‘Freja’ showed an approximately six-fold increase over that in pure stand, whereas in ‘T. Prentice’ the percentage of sterile flowers showed...

  13. Does a History of Unintended Pregnancy Lessen the Likelihood of Desire for Sterilization Reversal?

    Science.gov (United States)

    Grady, Cynthia D.; Schwarz, Eleanor Bimla; Emeremni, Chetachi A.; Yabes, Jonathan; Akers, Aletha; Zite, Nikki

    2013-01-01

    Abstract Background Unintended pregnancy has been significantly associated with subsequent female sterilization. Whether women who are sterilized after experiencing an unintended pregnancy are less likely to express desire for sterilization reversal is unknown. Methods This study used national, cross-sectional data collected by the 2006–2010 National Survey of Family Growth. The study sample included women ages 15–44 who were surgically sterile from a tubal sterilization at the time of interview. Multivariable logistic regression was used to examine the relationship between a history of unintended pregnancy and desire for sterilization reversal while controlling for potential confounders. Results In this nationally representative sample of 1,418 women who were sterile from a tubal sterilization, 78% had a history of at least one unintended pregnancy and 28% expressed a desire to have their sterilization reversed. In unadjusted analysis, having a prior unintended pregnancy was associated with higher odds of expressing desire for sterilization reversal (odds ratio [OR]: 1.80; 95% confidence interval [CI]: 1.15–2.79). In adjusted analysis controlling for sociodemographic factors, unintended pregnancy was no longer significantly associated with desire for reversal (OR: 1.46; 95% CI: 0.91–2.34). Conclusion Among women who had undergone tubal sterilization, a prior history of unintended pregnancy did not decrease desire for sterilization reversal. PMID:23621776

  14. 42 CFR 50.206 - Sterilization of a mentally incompetent individual or of an institutionalized individual.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization of a mentally incompetent individual..., DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.206 Sterilization of a mentally incompetent individual or...

  15. 42 CFR 50.203 - Sterilization of a mentally competent individual aged 21 or older.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization of a mentally competent individual... HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.203 Sterilization of a mentally competent individual aged 21 or older...

  16. THE EFFECTS OF DIFFERENT STEAM-STERILIZATION PROGRAMS ON MATERIAL PROPERTIES OF POLY(L-LACTIDE)

    NARCIS (Netherlands)

    ROZEMA, FR; BOS, RRM; BOERING, G; VANASTEN, JAAM; NIJENHUIS, AJ; PENNINGS, AJ

    1991-01-01

    As-polymerized poly(L-lactide) test rods were sterilized by seven different specially designed computer-operated autoclaving programs. As a control, common hospital sterilization was performed. In all cases, the molecular weight decreased after sterilization. A short time high-temperature

  17. The effects of inbreeding and heat stress on male sterility in Drosophila melanogaster

    DEFF Research Database (Denmark)

    Pedersen, Louise Dybdahl; Pedersen, Asger Roer; Bijlsma, Kuke

    2011-01-01

    in benign and stressful environments using Drosophila melanogaster as a model organism. Male sterility was compared in 21 inbred lines and five non-inbred control lines at 25.0 and 29.0 °C. The effect of inbreeding on sterility was significant only at 29.0 °C. This stress-induced increase in sterility...

  18. Does a history of unintended pregnancy lessen the likelihood of desire for sterilization reversal?

    Science.gov (United States)

    Grady, Cynthia D; Schwarz, Eleanor Bimla; Emeremni, Chetachi A; Yabes, Jonathan; Akers, Aletha; Zite, Nikki; Borrero, Sonya

    2013-06-01

    Unintended pregnancy has been significantly associated with subsequent female sterilization. Whether women who are sterilized after experiencing an unintended pregnancy are less likely to express desire for sterilization reversal is unknown. This study used national, cross-sectional data collected by the 2006-2010 National Survey of Family Growth. The study sample included women ages 15-44 who were surgically sterile from a tubal sterilization at the time of interview. Multivariable logistic regression was used to examine the relationship between a history of unintended pregnancy and desire for sterilization reversal while controlling for potential confounders. In this nationally representative sample of 1,418 women who were sterile from a tubal sterilization, 78% had a history of at least one unintended pregnancy and 28% expressed a desire to have their sterilization reversed. In unadjusted analysis, having a prior unintended pregnancy was associated with higher odds of expressing desire for sterilization reversal (odds ratio [OR]: 1.80; 95% confidence interval [CI]: 1.15-2.79). In adjusted analysis controlling for sociodemographic factors, unintended pregnancy was no longer significantly associated with desire for reversal (OR: 1.46; 95% CI: 0.91-2.34). Among women who had undergone tubal sterilization, a prior history of unintended pregnancy did not decrease desire for sterilization reversal.

  19. Female sterilization in India : The quality and effect of an observed sterilization camp at The Methodist Public Health Centre, Mursan, India

    OpenAIRE

    Wikborg, Pia; Svensk, Marie

    2007-01-01

    Population growth is a big challenge for India, and family planning is highly prioritized by the Government of India. Sterilization is the most common voluntary contraceptive method in India and has for many years been performed in camps. This thesis is based on our observation of a sterilization camp at the Methodist Public Health Centre in Mursan, India and available literature on the subject. We have looked closer at the effect of female sterilization as a method of contraception and t...

  20. Postpartum Permanent Sterilization: Could Bilateral Salpingectomy Replace Bilateral Tubal Ligation?

    Science.gov (United States)

    Danis, Rachel B; Della Badia, Carl R; Richard, Scott D

    2016-01-01

    There has recently been an expansion in the use of bilateral salpingectomy at the time of sterilization to theoretically decrease ovarian cancer risk. We sought to determine if postpartum salpingectomy is equivalent to postpartum bilateral tubal ligation (BTL) in terms of duration, estimated blood loss (EBL), and complication rate. A retrospective case series (Canadian Task Force Classification II-2). An academic inner-city hospital. All patients admitted for delivery of full-term intrauterine pregnancy desiring permanent sterilization between March 2014 and March 2015 were included. Excluded patients included those who had sterilization at the time of the cesarean section or other surgical procedure. Two cohorts were identified, those who had a planned postpartum tubal ligation and those having a postpartum salpingectomy. Postpartum sterilization. Researchers of this study recorded demographics, medical histories, and abdominal surgical histories for all patients who met the inclusion criteria. Surgical times, EBL, and complication rates were reviewed. Unpaired t test calculations were used to identify differences between age, body mass index, parity, and surgical time between the 2 cohorts. Chi-square tests were used to determine the statistical significance between complication rates, history of abdominal surgery, and past medical history of tubal disease between the 2 cohorts. Eighty women were identified, 64 in the BTL group and 16 in the salpingectomy cohort. The demographics of each cohort were equivocal. The average surgical time was 59.13 and 71.44 minutes in the BTL and salpingectomy cohorts, respectively. Of the 80 patients, only 1 had an EBL greater than 50 mL; this patient was in the BTL group. Four complications were noted in the BTL cohort, but none were evident in the salpingectomy group. There were no documented sterilization failures in the follow-up period (median = 9 months). Postpartum salpingectomy is slightly longer in duration but with

  1. Validation of the sterile manufacture of the AAEC MARK III molybdenum-99/techtnetium-99m generator

    International Nuclear Information System (INIS)

    Saunders, M.T.; Drummond, C.M.; Harrison, M.A.

    1982-07-01

    The Mark II molybdenum-99/technetium-99m generator now supplied to hospitals by the Australian Atomic Energy Commission is a non-sterile elution system. The Mark III version will be supplied as a sterile elution system. A validation study has been undertaken to assess the capability of the new production facility, to evaluate up-to-date procedures for manufacturing sterile generators and to demonstrate that a sterile radionuclide generator can be made. Generator manufacturing procedures and a time study of the validation are described. Microbiological methods for monitoring in-process aspects of manufacture, disinfectant efficacy and generator sterility are defined

  2. [Preparation of a polymer named Porimid, and its sterilization].

    Science.gov (United States)

    Mainard, D; Blech, M F; Mayllot, J P; Cuny, J; Lochon, P; Delagoutte, J P

    1992-01-01

    From a concrete example, the authors remind the interest to envisage the possibilities of sterilization as early as the initial period of a research about biomaterials. Indeed certain kinds of sterilization may be too much aggressive for biomaterials, especially the polymers, whom the structure is so impaired. These biomaterials may become ineffective even dangerous and blight a long time of research. The authors also expose the necessity to respect the good manufacturing practices of laboratory and the rules of hospital hygienics which is indispensable for all the members of the teams which participate to biomedical or clinical researches. A condition for the respect of these rules is the utilization of a common and well understood language between the medical and no medical teams.

  3. Management of maxillary avulsed teeth: using lasers for canal sterilization.

    Science.gov (United States)

    Gupta, Indra; Gupta, Satyendra; Sonwane, Kishore; Damankar, Dilip

    2011-07-01

    Avulsion or exarticulation accounts for up to 16% of all traumatic injuries. It is most common in age group of 7 to 14 years. Following the loss of anterior teeth, the replacement is necessary to maintain esthetics, phonetics and avoid arch length discrepancy. Following replantation, postoperative care and management is done in several ways. This article reports replantation and use of laser for endodontic sterilization and healing in a 12-year-old boy. It is suggested that replantation of an avulsed tooth as soon as possible using appropriate splint and regular followup will show good prognosis. Laser offers itself as a good alternative to Ca(OH)₂ for root canal sterilization and improved periapical healing.

  4. Ionization radiation in sterilization of the tissue transplants

    International Nuclear Information System (INIS)

    Uhrynowska-Tyszkiewicz, I.; Kaminski, A.

    2007-01-01

    Established in 1963, the Central Tissue Bank in Warsaw is a multi-tissue bank located in the Department of Transplantology of the Medical University in Warsaw. Allografts such as bone, cartilage, tendons, ligaments, sclera, skin and amnion are preserved mainly by deep-freezing and/or lyophilization and subsequently radiation-sterilized with a dose of 35 kGy with gamma rays in a 60 Co source (at the Institute of Applied Radiation Chemistry in Lodz) or with electron beam 10 MeV accelerator (at the Institute of Nuclear Chemistry and Technology in Warsaw). This is the oldest working tissue bank in the world, which for almost 40 years now has routinely used ionizing radiation for sterilization of tissue allografts

  5. Cosmological imprints of frozen-in light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Roland, Samuel B.; Shakya, Bibhushan, E-mail: rolandsa@umich.edu, E-mail: bshakya@umich.edu [Michigan Center for Theoretical Physics, University of Michigan, Ann Arbor, MI 48109 (United States)

    2017-05-01

    We investigate observable cosmological aspects of sterile neutrino dark matter produced via the freeze-in mechanism. The study is performed in a framework that admits many cosmologically interesting variations: high temperature production via annihilation processes from higher dimensional operators or low temperature production from decays of a scalar, with the decaying scalar in or out of equilibrium with the thermal bath, in supersymmetric or non-supersymmetric setups, thus allowing us to both extract generic properties and highlight features unique to particular variations. We find that while such sterile neutrinos are generally compatible with all cosmological constraints, interesting scenarios can arise where dark matter is cold, warm, or hot, has nontrivial momentum distributions, or provides contributions to the effective number of relativistic degrees of freedom N {sub eff} during Big Bang nucleosynthesis large enough to be probed by future measurements.

  6. Bacterial growth on Mueller Hinton medium sterilized by. gamma. -radiation

    Energy Technology Data Exchange (ETDEWEB)

    Eisenberg, E. (Israel Atomic Energy Commission, Yavne. Soreq Nuclear Research Center); Bogokowsky, B.; Altmann, G. (Sheba Medical Center, Tel Hashomer (Israel); Tel Aviv Univ. (Israel). Medical School)

    1981-12-01

    The possibility of radiosterilization of culture media for the cultivation of bacteria was investigated. Mueller Hinton agar, a medium widely used for the propagation of some fastidious pathogenic bacteria, was sterilized with 1.0 and 1.5 Mrad doses of ..gamma..-radiation. Bacteria belonging to seven different species grew as well on the radiosterilized medium as on medium sterilized by heat in a conventional way. Reduction in colony size was observed on the radiosterilized medium with Staphylococcus aureus and Shigella boydii. Neisseria meningitidis, the most fastidious bacterium tested, did not grow at all. The addition of small amounts of catalase corrected the deleterious radiation effect and all bacteria tested could be successfully grown on irradiated Mueller Hinton agar supplemented with up to 11 Keil units catalase per liter medium.

  7. Optimizing irradiation dose for sterility induction and quality of Bactrocera tryoni.

    Science.gov (United States)

    Collins, S R; Weldon, C W; Banos, C; Taylor, P W

    2009-10-01

    The current study is an important step toward calibrating, validating, and improving irradiation methods used for Bactrocera tryoni (Froggatt) sterile insect technique (SIT). We used routine International Atomic Energy Agency/U.S. Department of Agriculture/Food and Agriculture Organization quality control tests assessing percentage of emergence, flight ability, sex ratio, mortality under stress, reproductive sterility, and sexual competitiveness, as well as a nonstandard test of longevity under nutritional stress to assess the impact of a range of target irradiation doses (60, 65, 70, 75, and 80 Gy) on the product quality of mass reared B. tryoni used in SIT. Sterility induction remained adequate (>99.5%) for sterile male-fertile female crosses, and 100% sterility was achieved in fertile male-sterile female crosses and sterile male-sterile female crosses for each irradiation doses tested. There was significant increase in mortality under stress as irradiation dose increased, and reduced participation in mating by males irradiated at higher doses. The current target-sterilizing dose for SIT of 70-75 Gy is associated with significant reduction in fly product "quality". Our data suggest that adequate sterility and improved fly quality could be achieved through a small reduction in target sterilizing dose.

  8. The edible gelatin irradiation sterilization technology and quality control

    International Nuclear Information System (INIS)

    Fu Junjie; Shi Jianjun; Shen Weiqiao

    2000-01-01

    60 Co γ-ray irradiation sterilization technology was used in treating edible gelatin and the irradiation effects on viscosity, protein and amino acid were studied. The results demonstrated that the irradiation dose had negative correlation with viscosity, and there were no damage effects on the gelatin with 360 days storage under room temperature. According to D 10 Value, the suitable irradiation dose should be 3-5 kGy

  9. Light sterile neutrino sensitivity at the nuSTORM facility

    Energy Technology Data Exchange (ETDEWEB)

    Adey, D.; Agarwalla, S. K.; Ankenbrandt, C. M.; Asfandiyarov, R.; Back, J. J.; Barker, G.; Baussan, E.; Bayes, R.; Bhadra, S.; Blackmore, V.; Blondel, A.; Bogacz, S. A.; Booth, C.; Boyd, S. B.; Bramsiepe, S. G.; Bravar, A.; Brice, S. J.; Bross, A. D.; Cadoux, F.; Cease, H.; Cervera, A.; Cobb, J.; Colling, D.; Coloma, P.; Coney, L.; Dobbs, A.; Dobson, J.; Donini, A.; Dornan, P.; Dracos, M.; Dufour, F.; Edgecock, R.; Geelhoed, M.; Uchida, M. A.; Ghosh, T.; Gómez-Cadenas, J. J.; de Gouvêa, A.; Haesler, A.; Hanson, G.; Harrison, P. F.; Hartz, M.; Hernández, P.; Hernando Morata, J. A.; Hodgson, P.; Huber, P.; Izmaylov, A.; Karadzhov, Y.; Kobilarcik, T.; Kopp, J.; Kormos, L.; Korzenev, A.; Kuno, Y.; Kurup, A.; Kyberd, P.; Lagrange, J. B.; Laing, A.; Liu, A.; Link, J. M.; Long, K.; Mahn, K.; Mariani, C.; Martin, C.; Martin, J.; McCauley, N.; McDonald, K. T.; Mena, O.; Mishra, S. R.; Mokhov, N.; Morfín, J.; Mori, Y.; Murray, W.; Neuffer, D.; Nichol, R.; Noah, E.; Palmer, M. A.; Parke, S.; Pascoli, S.; Pasternak, J.; Plunkett, R.; Popovic, M.; Ratoff, P.; Ravonel, M.; Rayner, M.; Ricciardi, S.; Rogers, C.; Rubinov, P.; Santos, E.; Sato, A.; Sen, T.; Scantamburlo, E.; Sedgbeer, J. K.; Smith, D. R.; Smith, P. J.; Sobczyk, J. T.; Søby, L.; Soler, F. J. P.; Sorel, M.; Snopok, P.; Stamoulis, P.; Stanco, L.; Striganov, S.; Tanaka, H. A.; Taylor, I. J.; Touramanis, C.; Tunnell, C. D.; Uchida, Y.; Vassilopoulos, N.; Wascko, M. O.; Weber, A.; Wilking, M. J.; Wildner, E.; Winter, W.

    2014-04-01

    A facility that can deliver beams of electron and muon neutrinos from the decay of a stored muon beam has the potential to unambiguously resolve the issue of the evidence for light sterile neutrinos that arises in short-baseline neutrino oscillation experiments and from estimates of the effective number of neutrino flavors from fits to cosmological data. In this paper, we show that the nuSTORM facility, with stored muons of 3.8GeV/c±10%, will be able to carry out a conclusive muon neutrino appearance search for sterile neutrinos and test the LSND and MiniBooNE experimental signals with 10σ sensitivity, even assuming conservative estimates for the systematic uncertainties. This experiment would add greatly to our knowledge of the contribution of light sterile neutrinos to the number of effective neutrino flavors from the abundance of primordial helium production and from constraints on neutrino energy density from the cosmic microwave background. The appearance search is complemented by a simultaneous muon neutrino disappearance analysis that will facilitate tests of various sterile neutrino models.

  10. Can Sterilized FX Purchases under Inflation Targeting be Expansionary?

    OpenAIRE

    MArcio Gomes Pinto Garcia

    2011-01-01

    Unlike common wisdom, sterilized FX purchases under inflation targeting, i.e., those that keep the interest rate at the level targeted by the central bank, generally increase aggregate demand. We resort to a simple model with a credit channel to argue that FX purchases, by funding bank credit, end up increasing aggregate and money demand, while expanding loans and reducing the loan interest rate. Therefore, restoring the interest rate to the level previous to the FX purchase may not be suffic...

  11. Gamma-Ray Sterilization of Mars Analog Rocks and Minerals

    Science.gov (United States)

    Allen, C. C.

    1998-01-01

    Samples of rock and soil, collected by robotic spacecraft on Mars, will be returned to terrestrial laboratories early in the next century. Plans call for the samples to be placed immediately in biological containment and tested for signs of present or past life and biological hazard. It is recommended that "controlled distribution of unsterilized materials from Mars should occur only if rigorous analyses determine that the materials do not constitute a biological hazard. If any portion of the sample is removed from containment prior to completion of these analyses it should first be sterilized." While sterilization of Mars samples may not be required, an acceptable method must be available before the samples are returned to Earth. Various techniques are routinely used to sterilize biological samples. These include dry heating to temperatures of 150C or higher, heating in the presence of steam, exposure to poisonous gases such as formaldehyde and propiolactone, exposure to H2O2 vapor or plasma, exposure to ultraviolet light, and exposure to gamma radiation. The appropriate technique depends on the physical characteristics of the sample and the desired results. Gamma radiation is routinely used to inactivate viruses and destroy bacteria in medical research. The most commercial sterilizers use Cobalt 60, which emits gamma photons with energies of 1. 173 and 1. 332 MeV. Absorbed doses of approximately 106 rad (104 gamma ray is equal to 104 ergs/gm) are sufficient to destroy most bacteria. The current study is designed to investigate the effects of lethal doses of Cobalt 60 gamma radiation on geologic materials analogous to the first samples to be returned from Mars. The goals are (1) to determine the gamma ray dose required to kill microorganisms within geologic samples, and (2) to determine the effects of lethal doses of gamma radiation on the physical and chemical properties of the samples.

  12. Nursing wound care survey: sterile and nonsterile glove choice.

    Science.gov (United States)

    Wise, L C; Hoffman, J; Grant, L; Bostrom, J

    1997-05-01

    The application of sterile and clean procedure to the practice of wound care nursing was examined. This prospective, descriptive study surveyed staff nurses regarding glove use. Seven hundred forty-three staff nurses from five health care agencies in the San Francisco Bay Area responded to the survey. A self-report wound care survey instrument was developed by Nursing Consortium for Research and Practice members from information adapted from the wound care literature. The questionnaire comprised 31 questions and required approximately 10 minutes to complete. Nursing Consortium for Research and Practice members obtained approval from their respective institutional human subjects committees and distributed questionnaires among all nurses engaged in direct care. Some agency representatives personally handed the survey instruments to subjects, but most distributed them through their agencies personnel mailing systems. Seven hundred twenty-three (38%) of 1900 questionnaires were completed and returned to the five site coordinators. Differences were found between acute care and home health nurses. Acute care nurses were more likely than home care nurses to use sterile gloves in all wound care situations. Greater variation was found with regard to sterile technique in wound care practice than in previously reported studies. Although patient risk factors and wound type significantly influenced the choice of sterile or clean gloves, additional environmental and personal factors exerted considerable influence. These included health care setting, degree of professional education, and nurses' experiential background. Attempts to modify practice through policy change alone may not be sufficient to overcome resistance to change. Instead, it may be necessary for nurses to "unlearn" lessons from basic nursing education before they can adopt to new practices and clinical policies.

  13. Light sterile neutrinos and neutrinoless double-beta decay

    Science.gov (United States)

    Giunti, Carlo

    2017-10-01

    The LSND, Gallium and reactor neutrino anomalies can be explained by short-baseline neutrino oscillations due to the mixing of the active neutrinos with sterile neutrinos at the eV scale. I review the results of a 3+1 global fit of short-baseline neutrino oscillation data that includes the recent measurements of the MINOS, IceCube, and NEOS experiments, and I discuss the implications for neutrinoless double-beta decay.

  14. Accredited dose measurements for validation of radiation sterilized products

    DEFF Research Database (Denmark)

    Miller, A.

    1993-01-01

    for control of radiation sterilization. The accredited services include: 1. 1. Irradiation of dosimeters and test samples with cobalt-60 gamma rays. 2. 2. Irradiation of dosimeters and test samples with 10 MeV electrons. 3. 3. Issue of and measurement with calibrated dosimeters. 4. 4. Measurement...... of the dosimetric parameters of an irradiation facility. 5. 5. Measurement of absorbed dose distribution in irradiated products. The paper describes these services and the procedures necessary for their execution....

  15. Rugged Ozone Sterilization System Model M1 (ROSS M1)

    Science.gov (United States)

    2017-07-13

    sterilization technologies on the market . Design verification and validation testing requirements were established through investigation of the predicate...evaluation of their capability as part of a larger system, the process was controlled through manual operation of valves, pumps, and controls. Figure 1...to control the process without a manual interface. The initial software iterations were written as a computer interface which would connect to the

  16. Medical hospital materials processing: a literature review on sterilization effectiveness

    OpenAIRE

    Leonardo Mousinho Guerra; Oswaldo Lima Almendra Neto; Dayane Alves Costa; Gerardo Vasconcelos Mesquita

    2013-01-01

    Backgound and Objectives: Surgical instruments are widely reprocessed, mainly in developing countries, where the cost of using these materials is high. Scientifi c literature indicates the absence of validated cleaning and sterilization processes. The study aimed at evaluating, through a literature review, the evidence to support or not the practice of reprocessing and reuse of originally single-use, medical-hospital materials. Methods: A total of 27 articles in English and Portuguese were se...

  17. Sterile insect technique and radiation in insect control

    International Nuclear Information System (INIS)

    1982-01-01

    Out of 39 papers and 6 summaries of the poster presentations published in this proceeding series, 23 respectively fall within the INIS subject scope. Four main topics were covered: a review of the sterile insect technique against various insect pests; its application to tsetse flies in eradication programmes; quality control of mass-reared insects for release; and the development of genetic approaches to insect mass rearing and control. Other topics emphasized integrated pest management, computer models and radioisotope labelling

  18. Strategy for Searching for a Dark Matter Sterile Neutrino

    CERN Document Server

    Boyarsky, A; Ruchayskiy, O; Shaposhnikov, M E; Tkachev, I I

    2006-01-01

    We propose a strategy of how to look for dark matter (DM) particles possessing a radiative decay channel and derive constraints on their parameters from observations of X-rays from our own Galaxy and its dwarf satellites. When applied to the sterile neutrinos in keV mass range, it allows a significant improvement of restrictions to its parameters, as compared with previous works.

  19. [Sterility and fertility rites in the African tradition].

    Science.gov (United States)

    Erny, P

    1969-01-01

    The desire for numerous children in traditional Africa is recognized to have been a compelling social force. Women without children were pitied, feared, hated, or ostracized. 3 types of explanations of infertility were simultaneously entertained: some sort of anatomic or physiologic defect in the woman, some tribal ethic or taboo violated, or some metaphysical force or power interfering with conception and birth. Sterility was seldom attributed to the man and in most societies was a cause for divorce. The attitudes of medieval Europeans toward sterility in some respects paralleled those seen more recently in African native populations. Initiation rites, dolls and figurines of varied construction, exclusively female foods and other customary practices were invoked to protect the fertility of girls and women. If infertility persisted, a diviner or a series of diviners would be consulted in an effort to determine the cause. Some of the suggested cures were strictly speaking of a medical nature, but most were more in the nature of magic. If the cause was believed to lie in sorcery, a magicoreligious cure would be sought. The woman herself might identify some action she had committed or taboo she had violated as the cause of her problem, but more often the diviner or curer would do this. If the seer determined that the infertility was due to the action of a being of the other world, an ancestor, genie, or divinity, it was necessary to engage in a dialogue that culminated in prayer and sacrifice; such actions had a religious significance. Sterility was believed to be 1 of the means by which spirits or otherworld powers attracted the attention of the living when they wanted to establish relationships with them. It would then be necessary for a diviner to enter into communication with the spirit to understand its desires. Traditional remedies for sterility gave little true medical basis for cure except insofar as they relieved psychogenic causes.

  20. Autoclave Sterilization of PEDOT:PSS Electrophysiology Devices.

    Science.gov (United States)

    Uguz, Ilke; Ganji, Mehran; Hama, Adel; Tanaka, Atsunori; Inal, Sahika; Youssef, Ahmed; Owens, Roisin M; Quilichini, Pascale P; Ghestem, Antoine; Bernard, Christophe; Dayeh, Shadi A; Malliaras, George G

    2016-12-01

    Autoclaving, the most widely available sterilization method, is applied to poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) electrophysiology devices. The process does not harm morphology or electrical properties, while it effectively kills E. coli intentionally cultured on the devices. This finding paves the way to widespread introduction of PEDOT:PSS electrophysiology devices to the clinic. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Sterile insect technique for tsetse control and eradication

    International Nuclear Information System (INIS)

    1990-01-01

    The current publication contains the contributions made by scientists who participated in the fourth Co-ordinated Research Programme. A range of topics, covering both field and laboratory activities, was addressed: Eradication of Glossina palpalis palpalis (Robineau-Desvoidy) (Diptera: Glossinidae) from agropastoral land in Central Nigeria by means of the sterile insect technique; Research and development in the IAEA Laboratory at Seibersdorf in support of BICOT for the eradication of Glossina palpalis palpalis; Tsetse fly eradication in Burkina Faso and evaluation of traps and targets; Ecology of Glossina species inhabiting peridomestic agroecosystems in relation to options for tsetse fly control; Population dynamics of Glossina fuscipes fuscipes on Buvuma Island, Lake Victoria, Uganda; Population estimation from mark-recapture data: Equations for a pooled mark system and for pooled data, with applications to a study on island populations of tsetse flies in Zimbabwe; Surveillance of tsetse fly and cattle populations for trypanosomes in the BICOT area during the sterile insect technique control programme; Freeze dried blood and development of an artificial diet for blood feeding anthropods; Effects of the nutritional quality of locally obtained blood diets on the performance of Glossina palpalis palpalis fed in vitro; Mycetomes and symbionts of tsetse flies maintained on a membrane feeding system and the agents interfering with natural reproduction; Virus particles infection in laboratory reared Glossina pallidipes Austen (Diptera: Glossinidae); Influence of different nutritional sources on haemolymph composition and vitellogenesis in haematophagous arthropods; Effect of rearing diet on the injection rate in flies released for the control of tsetse populations by sterile males; Use of juvenile hormone mimics in the sterilization of tsetse flies; Studies of Glossina pallidipes and G. morsitans subspecies related to the genetic control of tsetse flies

  2. Multilevel Perspectives on Female Sterilization in Low-Income Communities in Mumbai, India.

    Science.gov (United States)

    Brault, Marie A; Schensul, Stephen L; Singh, Rajendra; Verma, Ravi K; Jadhav, Kalpita

    2016-09-01

    Surgical sterilization is the primary method of contraception among low-income women in India. This article, using qualitative analysis of key informant, in-depth interviews, and quantitative analyses, examines the antecedents, process, and outcomes of sterilization for women in a low-income area in Mumbai, India. Family planning policies, socioeconomic factors, and gender roles constrain women's reproductive choices. Procedures for sterilization rarely follow protocol, particularly during pre-procedure counseling and consent. Women who choose sterilization often marry early, begin conceiving soon after marriage, and reach or exceed ideal family size early due to problems in accessing reversible contraceptives. Despite these constraints, this study indicates that from the perspective of women, the decision to undergo sterilization is empowering, as they have fulfilled their reproductive duties and can effectively exercise control over their fertility and sexuality. This empowerment results in little post-sterilization regret, improved emotional health, and improved sexual relationships following sterilization. © The Author(s) 2015.

  3. Proposed Philippine radiation-sterilization plant, and a survey of market potential

    International Nuclear Information System (INIS)

    Singson, C.C.; Ibe, L.D.

    1975-01-01

    The paper deals with a study to assess the market potential of radiation sterilization in the Philippines. A market survey conducted with the technical assistance of an IAEA expert from India shows that most of the pharmaceutical industries engaged in the manufacture of medical products unanimously agree that there is an urgent need for a centralized radiation sterilization plant to meet the demands of sterilization of most of their products and packaging materials. The authorities of the government and some of the private hospitals surveyed are also very keen for the establishment of a sterilization facility since most modern medical products and devices are made of heat-sensitive thermoplastics which cannot be heat or steam sterilized. Availability of sterile products will help improve the public health standards of the population. The scope of the utilization of a radiation-sterilization facility in Diliman Quezon City is also discussed. (author)

  4. Distinguishing Dirac/Majorana sterile neutrinos at the LHC

    Science.gov (United States)

    Dib, Claudio O.; Kim, C. S.; Wang, Kechen; Zhang, Jue

    2016-07-01

    We study the purely leptonic decays of W±→e±e±μ∓ν and μ±μ±e∓ν produced at the LHC, induced by sterile neutrinos with mass mN below MW in the intermediate state. Since the final state neutrino escapes detection, one cannot tell whether this process violates lepton number, which would indicate a Majorana character for the intermediate sterile neutrino. Our study shows that when the sterile neutrino mixings with electrons and muons are different enough, one can still discriminate between the Dirac and Majorana character of this intermediate neutrino by simply counting and comparing the above decay rates. After performing collider simulations and statistical analysis, we find that at the 14 TeV LHC with an integrated luminosity of 3000 fb-1, for two benchmark scenarios mN=20 and 50 GeV, at least a 3 σ level of exclusion on the Dirac case can be achieved for disparities as mild as, e.g., |UN e|2UN μ|2 or |UN μ|2UN e|2 , provided that |UN e|2 and |UN μ|2 are both above ˜2 ×10-6.

  5. Atmospheric-pressure plasma decontamination/sterilization chamber

    Science.gov (United States)

    Herrmann, Hans W.; Selwyn, Gary S.

    2001-01-01

    An atmospheric-pressure plasma decontamination/sterilization chamber is described. The apparatus is useful for decontaminating sensitive equipment and materials, such as electronics, optics and national treasures, which have been contaminated with chemical and/or biological warfare agents, such as anthrax, mustard blistering agent, VX nerve gas, and the like. There is currently no acceptable procedure for decontaminating such equipment. The apparatus may also be used for sterilization in the medical and food industries. Items to be decontaminated or sterilized are supported inside the chamber. Reactive gases containing atomic and metastable oxygen species are generated by an atmospheric-pressure plasma discharge in a He/O.sub.2 mixture and directed into the region of these items resulting in chemical reaction between the reactive species and organic substances. This reaction typically kills and/or neutralizes the contamination without damaging most equipment and materials. The plasma gases are recirculated through a closed-loop system to minimize the loss of helium and the possibility of escape of aerosolized harmful substances.

  6. Genetic technologies to enhance the Sterile Insect Technique (SIT)

    Energy Technology Data Exchange (ETDEWEB)

    Alphey, Luke; Baker, Pam; Condon, George C.; Condon, Kirsty C.; Dafa' alla, Tarig H.; Fu, Guoliang; Jin, Li; Labbe, Genevieve; Morrison, Neil M.; Nimmo, Derric D.; O' Connell, Sinead; Phillips, Caroline E.; Plackett, Andrew; Scaife, Sarah; Woods, Alexander, E-mail: luke.alphey@zoo.ox.ac.u [Oxitec Ltd., Oxford (United Kingdom); Burton, Rosemary S.; Epton, Matthew J.; Gong, Peng [University of Oxford (United Kingdom). Dept. of Zoology

    2006-07-01

    The Sterile Insect Technique (SIT) has been used very successfully against range of pest insects, including various tephritid fruit flies, several moths and a small number of livestock pests. However, modern genetics could potentially provide several improvements that would increase the cost-effectiveness of SIT, and extend the range of suitable species. These include improved identification of released individuals by incorporation of a stable, heritable, genetic marker; built-in sex separation (genetic sexing); reduction of the hazard posed by non-irradiated accidental releases from mass-rearing facility (fail-safe); elimination of the need for sterilization by irradiation (genetic sterilization). We discuss applications of these methods and the state of the art, at the time of this meeting, in developing suitable strains. We have demonstrated, in several key pest species, that the required strains can be constructed by introducing a repressible dominant lethal genetic system, a method known as RIDL(trade mark). Based on field experience with Medfly, incorporation of a genetic sexing system into SIT programs for other tephritids could potentially provide a very significant improvement in cost-effectiveness. We have now been able to make efficient female-lethal strains for Medfly. One advantage of our approach is that it should be possible rapidly to extend this technology to other fruit fly species; indeed we have recently been able also to make genetic sexing strains of Medfly (Anastrepha ludens). (author)

  7. Dose setting for radiation sterilization of disposable medical device, (3)

    International Nuclear Information System (INIS)

    Iwasaki, Yoshio; Hosobuchi, Kazunari.

    1985-01-01

    The microbial burden and dose setting for radiation sterilization of tampon for menstrual hygiene were examined, and the following results were obtained. 1. The maximum and minimum contaminants per a tampon were 100 and 0, and the average was 46.1. 2. The 91.2 % of the 125 strains isolated from the tampon was identified as bacilli by the microbiological and biochemical activities, and Bacillus pumilus compried 35.2 % of the strains. B. pumilus and B. megaterium spores indicated the highest radioresistance among those contaminants and both D-values were 0.22 Mrad. 3. The difference in the D-value was not found for the radioresistance of standard strain carried on a tampon and a glass fiber filter. 4. The sterilization dose (SD) was calculated to be 1.10 Mrad by the formula SD = D x log (No/N), while the SD was 0.90 and 0.76 Mrad, respectively, for the microbial burden informations and steility tests. From above ressults, it is supposed that the sterility assurance level in 10 -3 can be achieved by irradiating the dose less than 1 Mrad. (author)

  8. Radiation sterilization of absorbent cotton and of absorbent gauze

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari; Oka, Mitsuru; Kaneko, Akira; Ishiwata, Hiroshi.

    1986-01-01

    The bioburden of absorbent cotton and of absorbent gauze and their physical and chemical characteristics after irradiation are investigated. The survey conducted on contaminants of 1890 cotton samples from 53 lots and 805 gauze samples from 56 lots showed maximum numbers of microbes per g of the cotton and gauze were 859 (an average of 21.4) and 777 (an average of 42.2), respectively. Isolation and microbiological and biochemical tests of representative microbes indicated that all of them, except one, were bacilli. The sterilization dose at 10 -6 of sterlity assurance level was found to be 2.0 Mrad when irradiated the spores loaded on paper strips and examined populations having graded D values from 0.10 to 0.28 Mrad. The sterilization dose would be about 1.5 Mrad if subjected the average numbers of contaminants observed in this study to irradiation. No significant differences were found between the irradiated samples and control up to 2 Mrad in tensile strength, change of color, absorbency, sedimentation rate, soluble substances, and pH of solutions used for immersion and other tests conventionally used. These results indicate that these products can be sterilized by irradiation. (author)

  9. No new cosmological concordance with massive sterile neutrinos.

    Science.gov (United States)

    Leistedt, Boris; Peiris, Hiranya V; Verde, Licia

    2014-07-25

    It has been claimed recently that massive sterile neutrinos could bring about a new concordance between observations of the cosmic microwave background, the large-scale structure of the Universe, and local measurements of the Hubble constant, H(0). We demonstrate that this apparent concordance results from combining data sets which are in significant tension, even within this extended model, possibly indicating remaining systematic biases in the measurements. We further show that this tension remains when the cosmological model is further extended to include significant tensor modes, as suggested by the recent BICEP2 results. Using the Bayesian evidence, we show that the cold dark matter model with a cosmological constant is strongly favored over its neutrino extensions by various combinations of data sets. Robust data combinations yield stringent limits of ∑m(ν) ≲ 0.3 eV and m(ν,sterile)(eff) ≲ 0.3 eV at 95% C.L. for the sum of active and sterile neutrinos, respectively.

  10. Early puerperal laparoscopic sterilization--a new technique.

    Directory of Open Access Journals (Sweden)

    Parulekar S

    1985-07-01

    Full Text Available This paper describes the results of 23 cases of puerperal laparoscopic sterilization performed within 72 hours of delivery. A new method was employed to avoid injury to the uterine fundus and to make the tubes more accessible. Before insertion of the Veress needle, the anterior and posterior lips of the cervix were held with forceps and Hulka′s uterine manipulator was introduced into the uterine cavity. The uterus was pulled down toward the introitus by applying traction to the sponge-holding forceps. Pneumoperitoneum of 3-4 liters was induced through use of a Veress needle, followed by introduction of a Storz single puncture operative laparoscope through an incision in the lower umbilical fold. Tubal occlusion was achieved with silastic bands. The average time required for sterilization from induction of general anesthesia was 6 minutes. There was no instance of injury to the uterine fundus, nor were there any cases of uterine perforation, injury to other pelvic structures, laceration of the cervix, or puerperal sepsis. At the time of follow-up 15 days after the procedure, all patients were in satisfactory condition. It is concluded that this method can enhance postpartum family planning programs. Since it can be carried out within the 1st 48 hours after delivery, the routine hospital stay of 3 days does not have to be prolonged as a result of sterilization.

  11. Quinacrine non-surgical female sterilization in Bangladesh.

    Science.gov (United States)

    Bhuiyan, S N; Begum, R

    2001-11-01

    This study was undertaken to evaluate the efficacy, safety, and acceptability of transcervical applications of quinacrine along with other adjuvants, such as ampicillin and ibuprofen, for sterilization. The cohort consisted of 750 normal women who requested sterilization and volunteered for this method at the family planning clinic of a tertiary hospital and community clinics in Chittagong, Bangladesh. Several different protocols were followed from October 1989 to April 1999. Each woman received one or two insertions of 180 mg or 252 mg quinacrine with or without adjuvants including 55.5 mg ibuprofen or 125 mg ampicillin. Supplementary contraception was given in the form of combined oral contraceptive pills, barrier methods, or injection of depot medroxyprogesterone acetate for 3 months. Details of each protocol are described in the text. The gross pregnancy failure rate for insertion of 180 mg in 590 women was 3.9% compared to 1.9% for the 160 who received 252 mg. There were no serious complications, and side effects were transient. We conclude that quinacrine non-surgical sterilization is a safe, acceptably effective method when two insertions of 252 mg quinacrine with medroxyprogesterone injection as a supplement is used.

  12. Genetic technologies to enhance the Sterile Insect Technique (SIT)

    International Nuclear Information System (INIS)

    Alphey, Luke; Baker, Pam; Condon, George C.; Condon, Kirsty C.; Dafa'alla, Tarig H.; Fu, Guoliang; Jin, Li; Labbe, Genevieve; Morrison, Neil M.; Nimmo, Derric D.; O'Connell, Sinead; Phillips, Caroline E.; Plackett, Andrew; Scaife, Sarah; Woods, Alexander; Burton, Rosemary S.; Epton, Matthew J.; Gong, Peng

    2006-01-01

    The Sterile Insect Technique (SIT) has been used very successfully against range of pest insects, including various tephritid fruit flies, several moths and a small number of livestock pests. However, modern genetics could potentially provide several improvements that would increase the cost-effectiveness of SIT, and extend the range of suitable species. These include improved identification of released individuals by incorporation of a stable, heritable, genetic marker; built-in sex separation (genetic sexing); reduction of the hazard posed by non-irradiated accidental releases from mass-rearing facility (fail-safe); elimination of the need for sterilization by irradiation (genetic sterilization). We discuss applications of these methods and the state of the art, at the time of this meeting, in developing suitable strains. We have demonstrated, in several key pest species, that the required strains can be constructed by introducing a repressible dominant lethal genetic system, a method known as RIDL(trade mark). Based on field experience with Medfly, incorporation of a genetic sexing system into SIT programs for other tephritids could potentially provide a very significant improvement in cost-effectiveness. We have now been able to make efficient female-lethal strains for Medfly. One advantage of our approach is that it should be possible rapidly to extend this technology to other fruit fly species; indeed we have recently been able also to make genetic sexing strains of Medfly (Anastrepha ludens). (author)

  13. Distinguishing Dirac/Majorana sterile neutrinos at the LHC

    International Nuclear Information System (INIS)

    Dib, Claudio O.; Zhang, Jue

    2016-06-01

    We study the purely leptonic decays of W ± → e ± e ± μ -+ ν and μ ± μ ± e -+ ν produced at the LHC, induced by sterile neutrinos with mass m N below M W in the intermediate state. Since the final state neutrino escapes detection, one cannot tell whether this process violates lepton number, what would indicate a Majorana character for the intermediate sterile neutrino. Our study shows that when the sterile neutrino mixings with electrons and muons are different enough, one can still discriminate between the Dirac and Majorana character of this intermediate neutrino by simply counting and comparing the above decay rates. After performing collider simulations and statistical analysis, we find that at the 14 TeV LHC with an integrated luminosity of 3000 fb -1 , for two benchmark scenarios m N =20 GeV and 50 GeV, at least a 3σ level of exclusion on the Dirac case can be achieved for disparities as mild as e.g. vertical stroke U Ne vertical stroke 2 <0.7 vertical stroke U Nμ vertical stroke 2 or vertical stroke U Nμ vertical stroke 2 <0.7 vertical stroke U Ne vertical stroke 2 , provided that vertical stroke U Ne vertical stroke 2 , vertical stroke U Nμ vertical stroke 2 are both above ∝2 x 10 -6 .

  14. Evidence and Search for Sterile Neutrinos at Accelerators

    Directory of Open Access Journals (Sweden)

    W. C. Louis

    2013-01-01

    Full Text Available The LSND short-baseline neutrino experiment has published evidence for antineutrino oscillations at a mass scale of ~1 eV2. The MiniBooNE experiment, designed to test this evidence for oscillations at an order of magnitude higher neutrino energy and distance, observes excesses of events in both neutrino mode and antineutrino mode. While the MiniBooNE neutrino excess has a neutrino energy spectrum that is softer than expected from LSND, the MiniBooNE antineutrino excess is consistent with neutrino oscillations and with the LSND oscillation signal. When combined with oscillation measurements at the solar and atmospheric mass scales, assuming that the LSND and MiniBooNE signals are due to neutrino oscillations, these experiments imply the existence of more than three neutrino mass states and, therefore, one or more sterile neutrinos. Such sterile neutrinos, if proven to exist, would have a big impact on particle physics, nuclear physics, and astrophysics and would contribute to the dark matter of the universe. Future experiments under construction or proposed at Fermilab, ORNL, CERN, and in Japan will provide a definitive test of short-baseline neutrino oscillations and will have the capability of proving the existence of sterile neutrinos.

  15. Antioxidant properties of sterilized yacon (Smallanthus sonchifolius) tuber flour.

    Science.gov (United States)

    Sousa, Sérgio; Pinto, Jorge; Rodrigues, César; Gião, Maria; Pereira, Claúdia; Tavaria, Freni; Malcata, F Xavier; Gomes, Ana; Bertoldo Pacheco, M T; Pintado, Manuela

    2015-12-01

    The objective of this research work was to investigate the antioxidant properties of sterilized yacon tuber flour. The results revealed for the first time the high antioxidant activity of sterilized yacon flour. The best extract obtained by boiling 8.9% (w/v) of yacon flour in deionised water for 10 min exhibited a total antioxidant capacity of 222±2 mg (ascorbic acid equivalent)/100 g DW and a total polyphenol content of 275±3 mg (gallic acid equivalent)/100 g DW associated to the presence of four main phenolic compounds: chlorogenic acid, caffeic acid, coumaric acid and protocatechuic acid, as well as the amino acid tryptophan. The most abundant was chlorogenic acid, followed by caffeic acid. Biological assays revealed that the extract had indeed antioxidant protection, and no pro-oxidant activity. In conclusion, sterilized yacon tuber flour has the potential to be used in the food industry as a food ingredient to produce functional food products. Copyright © 2015. Published by Elsevier Ltd.

  16. Axion-assisted production of sterile neutrino dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Berlin, Asher; Hooper, Dan

    2017-04-12

    Sterile neutrinos can be generated in the early universe through oscillations with active neutrinos and represent a popular and well-studied candidate for our universe's dark matter. Stringent constraints from X-ray and gamma-ray line searches, however, have excluded the simplest of such models. In this letter, we propose a novel alternative to the standard scenario in which the mixing angle between the sterile and active neutrinos is a dynamical quantity, induced through interactions with a light axion-like field. As the energy density of the axion-like particles is diluted by Hubble expansion, the degree of mixing is reduced at late times, suppressing the decay rate and easily alleviating any tension with X-ray or gamma-ray constraints. We present a simple model which illustrates the phenomenology of this scenario, and also describe a framework in which the QCD axion is responsible for the production of sterile neutrinos in the early universe.

  17. Sterility and the disinfection potential of Indian contact lens solutions

    Directory of Open Access Journals (Sweden)

    Gopinathan Usha

    1994-01-01

    Full Text Available Ocular infection associated with microbial contamination of contact lens care products is a major problem in contact lens wearers. The sterility and the antimicrobial activity of contact lens care systems reflect their suitability for disinfection of contact lenses. These factors remain to be evaluated for the various newer contact lens care products manufactured in India. In this study, 35 bottles of contact lens solutions marketed by different manufacturing units in India were tested for sterility. Seven solutions were tested for antimicrobial effectiveness employing the D value method of analysis. The D value is defined as the time required to reduce a population of organisms by 90% (one log unit. A standard inoculum of the ocular isolates of Staphylococcus aureus, Pseudomonas aeruginosa, Serratia marcescens, Aspergillus fumigatus, Fusarium solani, and Acanthamoeba castellanii were used as challenge organisms. Bacterial contamination was detected in 20 (57.1% solution bottles and none yielded fungus or Acanthamoeba. Pseudomonas species were the most commonly encountered contaminant (11/20; 55%. Only sterile solutions were analyzed for antimicrobial activity. D values ranging between 12 and 20 minutes were demonstrated by six of the seven solutions against bacterial challenge. Good antifungal activity was noticed in five solutions against Fusarium solani though results varied with Aspergillus flavus and Candida albicans. All solutions were adequately effective against Acanthamoeba.

  18. Light sterile neutrino sensitivity at the nuSTORM facility

    CERN Document Server

    Adey, D; Ankenbrandt, C.M.; Asfandiyarov, R.; Back, J.J.; Barker, G.; Baussan, E.; Bayes, R.; Bhadra, S.; Blackmore, V.; Blondel, A.; Bogacz, S.A.; Booth, C.; Boyd, S.B.; Bramsiepe, S.G.; Bravar, A.; Brice, S.J.; Bross, A.D.; Cadoux, F.; Cease, H.; Cervera, A.; Cobb, J.; Colling, D.; Coloma, P.; Coney, L.; Dobbs, A.; Dobson, J.; Donini, A.; Dornan, P.; Dracos, M.; Dufour, F.; Edgecock, R.; Geelhoed, M.; Uchida, M.A.; Ghosh, T.; Gomez-Cadenas, J.J.; de Gouvea, A.; Haesler, A.; Hanson, G.; Harrison, P.F.; Hartz, M.; Hernandez, P.; Hernando Morata, J.A.; Hodgson, P.; Huber, P.; Izmaylov, A.; Karadzhov, Y.; Kobilarcik, T.; Kopp, J.; Kormos, L.; Korzenev, A.; Kuno, Y.; Kurup, A.; Kyberd, P.; Lagrange, J.B.; Laing, A.; Liu, A.; Link, J.M.; Long, K.; Mahn, K.; Mariani, C.; Martin, C.; Martin, J.; McCauley, N.; McDonald, K.T.; Mena, O.; Mishra, S.R.; Mokhov, N.; Morfin, J.; Mori, Y.; Murray, W.; Neuffer, D.; Nichol, R.; Noah, E.; Palmer, M.A.; Parke, S.; Pascoli, S.; Pasternak, J.; Plunkett, R.; Popovic, M.; Ratoff, P.; Ravonel, M.; Rayner, M.; Ricciardi, S.; Rogers, C.; Rubinov, P.; Santos, E.; Sato, A.; Sen, T.; Scantamburlo, E.; Sedgbeer, J.K.; Smith, D.R.; Smith, P.J.; Sobczyk, J.T.; Sby, L.; Soler, F.J.P.; Sorel, M.; Snopok, P.; Stamoulis, P.; Stanco, L.; Striganov, S.; Tanaka, H.A.; Taylor, I.J.; Touramanis, C.; Tunnell, C.D.; Uchida, Y.; Vassilopoulos, N.; Wascko, M.O.; Weber, A.; Wilking, M.J.; Wildner, E.; Winter, W.

    2014-01-01

    A facility that can deliver beams of electron and muon neutrinos from the decay of a stored muon beam has the potential to unambiguously resolve the issue of the evidence for light sterile neutrinos that arises in short-baseline neutrino oscillation experiments and from estimates of the effective number of neutrino flavors from fits to cosmological data. In this paper, we show that the nuSTORM facility, with stored muons of 3.8 GeV/c $\\pm$ 10%, will be able to carry out a conclusive muon neutrino appearance search for sterile neutrinos and test the LSND and MiniBooNE experimental signals with 10$\\sigma$ sensitivity, even assuming conservative estimates for the systematic uncertainties. This experiment would add greatly to our knowledge of the contribution of light sterile neutrinos to the number of effective neutrino flavors from the abundance of primordial helium production and from constraints on neutrino energy density from the cosmic microwave background. The appearance search is complemented by a simulta...

  19. A Sterile-Neutrino Search with the MINOS Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Philip [Univ. of Oxford (United Kingdom)

    2010-01-01

    The MINOS experiment is a long-baseline neutrino oscillation experiment in the the NuMI beamline at Fermilab, USA. Using a near detector at 1 km distance from the neutrino production target, and a far detector at 735 km from the target, it is designed primarily to measure the disappearance of muon neutrinos. This thesis presents an analysis using MINOS data of the possibility of oscil- lation of the neutrinos in the NuMI beam to a hypothetical sterile flavour, which would have no Standard Model couplings. Such oscillations would result in a deficit in the neutral current interaction rate in the MINOS far detector relative to the expectation derived from the near detector data. The method used to identify neutral current and charged current events in the MINOS detectors is described and a new method of predicting and fitting the far detector spectrum presented, along with the effects of systematic uncertainties on the sterile neutrino oscillation analysis. Using this analysis, the fraction fs of the disappearing neutrinos that go to steriles is constrained to be below 0.15 at the 90% confidence level in the absence of electron neutrino appearance in the NuMI beam. With electron appearance at the CHOOZ limit, fs < 0.41 at 90% C.L.

  20. Association of Hysteroscopic vs Laparoscopic Sterilization With Procedural, Gynecological, and Medical Outcomes.

    Science.gov (United States)

    Bouillon, Kim; Bertrand, Marion; Bader, Georges; Lucot, Jean-Philippe; Dray-Spira, Rosemary; Zureik, Mahmoud

    2018-01-23

    Safety of hysteroscopic sterilization has been recently questioned following reports of general symptoms such as allergy, tiredness, and depression in addition to associated gynecological results such as pelvic pain, perforation of fallopian tubes or uterus, and unwanted pregnancy. To compare the risk of reported adverse events between hysteroscopic and laparoscopic sterilization. French nationwide cohort study using the national hospital discharge database linked to the health insurance claims database. Women aged 30 to 54 years receiving a first hysteroscopic or laparoscopic sterilization between 2010 and 2014 were included and were followed up through December 2015. Hysteroscopic sterilization vs laparoscopic sterilization. Risks of procedural complications (surgical and medical) and of gynecological (sterilization failure that includes salpingectomy, second sterilization procedure, or pregnancy; pregnancy; reoperation) and medical outcomes (all types of allergy; autoimmune diseases; thyroid disorder; use of analgesics, antimigraines, antidepressants, benzodiazepines; outpatient visits; sickness absence; suicide attempts; death) that occurred within 1 and 3 years after sterilization were compared using inverse probability of treatment-weighted Cox models. Of the 105 357 women included (95.5% of eligible participants; mean age, 41.3 years [SD, 3.7 years]), 71 303 (67.7% ) underwent hysteroscopic sterilization, and 34 054 (32.3%) underwent laparoscopic sterilization. During the hospitalization for sterilization, risk of surgical complications for hysteroscopic sterilization was lower: 0.13% for hysteroscopic sterilization vs 0.78% for laparoscopic sterilization (adjusted risk difference [RD], -0.64; 95% CI, -0.67 to -0.60) and was lower for medical complications: 0.06% vs 0.11% (adjusted RD, -0.05; 95% CI, -0.08 to -0.01). During the first year after sterilization, 4.83% of women who underwent hysteroscopic sterilization had a higher risk of sterilization

  1. Acute sterile endophthalmitis following intravitreal bevacizumab: case series

    Directory of Open Access Journals (Sweden)

    Orozco-Hernández A

    2014-09-01

    Full Text Available Axel Orozco-Hernández,1 Ximena Ortega-Larrocea,1 Gustavo Sánchez-Bermúdez,1 Gerardo García-Aguirre,1 Virgilio Morales Cantón,1 Raul Velez-Montoya2 1Retina Department, Asociación para Evitar la Ceguera en México IAP, Mexico City, Mexico; 2Department of Ophthalmology, University of Colorado School of Medicine, Rocky Mountain Lions Eye Institute, Aurora, CO, USA Background: Since the ophthalmological community adopted the use of intravitreal bevacizumab as an accepted off-label treatment for neovascular diseases, the amount of knowledge regarding its effects and properties has been increasing continually. In the last few years, there have been an increasing number of reports about sterile intraocular inflammation and intraocular pressure elevations after intravitreal bevacizumab. In the following case series, we describe the clinical presentation and outcomes of ten consecutive cases of patients developing mild-to-severe sterile intraocular inflammation after intravitreal bevacizumab and their management. Methods: This report presents a retrospective case series. We reviewed the medical records of ten consecutive patients from a group of 46, in whom repackaged bevacizumab in individual aliquots from two vials from the same batch were used. All surgical procedures were performed using standard sterile techniques in the operating room. At each follow-up visit, patients underwent a complete ophthalmological examination including visual acuity assessment, intraocular pressure, biomicroscopy, and posterior fundus examination. Results: Ten patients presented sterile endophthalmitis with an onset time of 3.5±1.95 days. The clinical characteristics were mild pain, slight visual loss, conjunctival hyperemia, and various degrees of intraocular inflammation with microhypopyon. All cultures were negative. All patients were managed with topical steroids and antibiotics, except two, in whom, due to severe vitreous cells, intravitreal antibiotics were

  2. Oviposition punctures in cucurbit fruits and their economic damage caused by the sterile female melon fly, Bactrocera cucurbitae Coquillett

    International Nuclear Information System (INIS)

    Miyatake, T.; Irabu, T.; Higa, R.

    1993-01-01

    Oviposition punctures caused by sterile females of the tephritid Bactrocera cucurbitae in cucurbit fruits were examined and economic damage was evaluated in Okinawa, Ryukyu Archipelago, Japan. Cage experiments in the field confirmed that sterile females make punctures (sterile stings) on fruits. The features of sterile stings differed depending on fruit species and were classified into 5 types

  3. Towards male sterility in Pinus radiata--a stilbene synthase approach to genetically engineer nuclear male sterility.

    Science.gov (United States)

    Höfig, Kai P; Möller, Ralf; Donaldson, Lloyd; Putterill, Joanna; Walter, Christian

    2006-05-01

    A male cone-specific promoter from Pinus radiata D. Don (radiata pine) was used to express a stilbene synthase gene (STS) in anthers of transgenic Nicotiana tabacum plants, resulting in complete male sterility in 70% of transformed plants. Three plants were 98%-99.9% male sterile, as evidenced by pollen germination. To identify the stage at which transgenic pollen first developed abnormally, tobacco anthers from six different developmental stages were assayed microscopically. Following the release of pollen grains from tetrads, transgenic pollen displayed an increasingly flake-like structure, which gradually rounded up during the maturation process. We further investigated whether STS expression may have resulted in an impaired flavonol or sporopollenin formation. A specific flavonol aglycone stain was used to demonstrate that significant amounts of these substances were produced only in late stages of normal pollen development, therefore excluding a diminished flavonol aglycone production as a reason for pollen ablation. A detailed analysis of the exine layer by transmission electron microscopy revealed minor structural changes in the exine layer of ablated pollen, and pyrolysis-gas chromatography-mass spectroscopy indicated that the biochemistry of sporopollenin production was unaffected. The promoter-STS construct may be useful for the ablation of pollen formation in coniferous gymnosperms and male sterility may potentially be viewed as a prerequisite for the commercial use of transgenic conifers.

  4. Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments.

    Science.gov (United States)

    Viana, A C D; Gonzalez, B M; Buono, V T L; Bahia, M G A

    2006-09-01

    To evaluate the effect of repeated sterilization cycles in dry oven or autoclave, on the mechanical behaviour and fatigue resistance of rotary endodontic Ni-Ti instruments. New Ni-Ti instruments were subjected to five consecutive sterilization cycles in a dry oven or steam autoclave. Microhardness was measured in the nonmachined parts of the shanks of instruments using a Vickers indenter. Specimens of Ni-Ti wires were submitted to the same sterilization protocol and tensile tested until rupture. A group of instruments were fatigued to one half of their average fatigue life and then sterilized. New and sterilized instruments were fatigue tested until rupture. anova tests at alpha = 0.05 were used for statistical analysis. Sterilization procedures resulted in no significant changes in Vickers microhardness, nor in the parameters describing the mechanical behaviour of the wires. However, the number of cycles to failure was statistically higher for all instruments after dry heat or autoclave sterilization cycles. In the instruments previously fatigued to one half of their fatigue life, autoclave sterilization gave rise to an increase of 39% in the remaining number of cycles to failure. Changes in the mechanical properties of Ni-Ti endodontic instruments after five cycles of commonly used sterilization procedures were insignificant. The sterilization procedures are safe as they produced a significant increase in the fatigue resistance of the instruments.

  5. Do women's attitudes towards abortion and contraceptive methods influence their option for sterilization?

    Directory of Open Access Journals (Sweden)

    Vieira Elisabeth Meloni

    1999-01-01

    Full Text Available This paper analyzes the attitudes of low-income women towards abortion and contraception. A survey was conducted in 1992 with a total of 3,149 childbearing-age women living on the outskirts of the Greater Metropolitan São Paulo Area. The study focuses on a sub-sample of 583 women. Attitudes of sterilized and non-sterilized women are compared. Women, especially those sterilized, found the most important attribute of a contraceptive method to be its effectiveness. Women currently taking the pill were less likely than those sterilized to agree that sterilization was the best method because of its effectiveness. Sterilized women were less likely than non-sterilized women to trust the pill. Sterilized women were more likely than non-sterilized to have reported adverse effects from the pill. Most women found abortion unacceptable except in the case of risk to the woman's life. Women using more effective methods showed stronger negative attitudes towards abortion. The tendency to be sterilized while still young was associated with more negative attitudes towards abortion. Family planning activities in basic health care services should include individual counseling for contraceptive use.

  6. Do women's attitudes towards abortion and contraceptive methods influence their option for sterilization?

    Directory of Open Access Journals (Sweden)

    Elisabeth Meloni Vieira

    Full Text Available This paper analyzes the attitudes of low-income women towards abortion and contraception. A survey was conducted in 1992 with a total of 3,149 childbearing-age women living on the outskirts of the Greater Metropolitan São Paulo Area. The study focuses on a sub-sample of 583 women. Attitudes of sterilized and non-sterilized women are compared. Women, especially those sterilized, found the most important attribute of a contraceptive method to be its effectiveness. Women currently taking the pill were less likely than those sterilized to agree that sterilization was the best method because of its effectiveness. Sterilized women were less likely than non-sterilized women to trust the pill. Sterilized women were more likely than non-sterilized to have reported adverse effects from the pill. Most women found abortion unacceptable except in the case of risk to the woman's life. Women using more effective methods showed stronger negative attitudes towards abortion. The tendency to be sterilized while still young was associated with more negative attitudes towards abortion. Family planning activities in basic health care services should include individual counseling for contraceptive use.

  7. Applying the sterile insect technique to the control of insect pests

    International Nuclear Information System (INIS)

    LaChance, L.E.; Klassen, W.

    1991-01-01

    The sterile insect technique involves the mass-rearing of insects, which are sterilized by gamma rays from a 60 Co source before being released in a controlled fashion into nature. Matings between the sterile insects released and native insects produce no progeny, and so if enough of these matings occur the pest population can be controlled or even eradicated. A modification of the technique, especially suitable for the suppression of the moths and butterflies, is called the F, or inherited sterility method. In this, lower radiation doses are used such that the released males are only partially sterile (30-60%) and the females are fully sterile. When released males mate with native females some progeny are produced, but they are completely sterile. Thus, full expression of the sterility is delayed by one generation. This article describes the use of the sterile insect technique in controlling the screwworm fly, the tsetse fly, the medfly, the pink bollworm and the melon fly, and of the F 1 sterility method in the eradication of local gypsy moth infestations. 18 refs, 5 figs, 1 tab

  8. Racial variation in tubal sterilization rates: The role of patient-level factors

    Science.gov (United States)

    Borrero, Sonya; Abebe, Kaleab; Dehlendorf, Christine; Schwarz, Eleanor Bimla; Creinin, Mitchell D.; Nikolajski, Cara; Ibrahim, Said

    2010-01-01

    Objective To assess racial differences in attitudes and knowledge about sterilization. Design Cross-sectional survey Setting Questionnaires were mailed to participants’ home addresses Patients 193 women aged 18–45 who had undergone tubal sterilization. Intervention(s) None Main Outcome Measure Attitudes and knowledge about tubal sterilization and awareness of contraceptive alternatives Results We received 193 completed surveys (64% response rate). AA woman were more likely to have a family member who had undergone tubal sterilization, to report that their mothers influenced their sterilization decisions, and to report that prior unintended pregnancy and desire to avoid insertion of a foreign object were very important factors in their decision to choose sterilization over other methods. Compared to white women, AA women more often thought that sterilization reversal could easily restore fertility (62 % vs 36%); that a woman’s sterilization would reverse itself after 5 years (60% vs 23%); and that a man cannot ejaculate after vasectomy (38% vs 13%). Fewer AA women had ever heard of intrauterine contraception (90% vs 98%). Racial differences in knowledge remained statistically significant after adjusting for socioeconomic confounders. Conclusions Misinformation about sterilization and limited awareness of contraceptive alternatives among AA women may contribute to racial disparities in tubal sterilization rates. PMID:20579640

  9. Effect of disinfection and sterilization on the tensile strength, surface roughness, and wettability of elastomers.

    Science.gov (United States)

    Kotha, Sunil Babu; Ramakrishnaiah, Ravikumar; Devang Divakar, Darshan; Celur, Sree Lalita; Qasim, Saad; Matinlinna, Jukka P

    2017-11-01

    The aim of the present study was to evaluate the effect of chemical disinfection, autoclave, and microwave sterilization on some of the key properties of elastomers. Five polyvinylsiloxane elastomeric impression materials were evaluated. Forty samples were fabricated from each material. The samples were randomly selected and assigned to four experimental groups with 50 samples each: group I, control; group II,chemical disinfection; group III, autoclave sterilization; and group IV, microwave sterilization. The differences in the mean values were contrasted and compared with the control group and analyzed using two-way analysis of variance (P autoclave sterilization had no significant effect on the tensile strength and surface roughness, whereas microwave sterilization showed a statistically-significant reduction in tensile strength, and an increase in surface roughness. None of the disinfection and sterilization techniques had a significant effect on wettability. However, autoclave and microwave sterilization resulted in an increase in hydrophilicity of all the materials tested. Chemical disinfection and autoclave sterilization had no statistically-significant effect on the tested properties of elastomers, thus autoclave sterilization can be considered as an alternative and an effective mode of disinfection and sterilization to eliminate all forms of disease causing microorganisms from dental impressions. © 2016 John Wiley & Sons Australia, Ltd.

  10. Evaluation of steam sterilization conditions for [{sup 18}F]fludeoxyglucose

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Priscilla F.; Nascimento, Leonardo T.; Valente, Eduardo S.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z., E-mail: somafe@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Unidade de Pesquisa e Producao de Radiofarmacos

    2011-07-01

    [{sup 18}F]Flu deoxyglucose ({sup 18}FDG) is the most commonly used radiopharmaceutical for positron emission tomography. Sterile filtration of the final product into sterile vials using 0.22 {mu}m filter membrane is usually adopted for {sup 18}FDG. However, Good Manufacturing Practice (GMP) guidelines recommend heat sterilization as the method of choice to ensure sterility of pharmaceutical preparations. The aim of this study was to essay different steam sterilization conditions in order to choose the best one for {sup 18}FDG. Three different sterilization conditions were essayed. The first one at 121 deg C for 15 minutes, the second one at 135 deg C for 3.5 minutes and the third one at 133 deg C for 2 minutes. {sup 18}FDG pH-formulation was kept around 6.0. At the end of autoclave cycles, {sup 18}FDG sterility was evaluated by direct inoculation of {sup 18}FDG in culture media and radiochemical purity was determined by TLC and HPLC. Results demonstrated that all essayed conditions were able to ensure {sup 18}FDG sterility, but caused a decrease in radiochemical purity of {sup 18}FDG. Autoclave cycle at 133 deg C for 2 minutes was the best essayed condition for {sup 18}FDG terminal sterilization, once it provided the greater radiochemical purity value and took less time. {sup 18}FDG was able to meet specifications after autoclave cycles, what supports the application of steam sterilization in routine {sup 18}FDG production, in compliance with GMP. (author)

  11. Potential unintended pregnancies averted and cost savings associated with a revised Medicaid sterilization policy.

    Science.gov (United States)

    Borrero, Sonya; Zite, Nikki; Potter, Joseph E; Trussell, James; Smith, Kenneth

    2013-12-01

    Medicaid sterilization policy, which includes a mandatory 30-day waiting period between consent and the sterilization procedure, poses significant logistical barriers for many women who desire publicly funded sterilization. Our goal was to estimate the number of unintended pregnancies and the associated costs resulting from unfulfilled sterilization requests due to Medicaid policy barriers. We constructed a cost-effectiveness model from the health care payer perspective to determine the incremental cost over a 1-year time horizon of the current Medicaid sterilization policy compared to a hypothetical, revised policy in which women who desire a postpartum sterilization would face significantly reduced barriers. Probability estimates for potential outcomes in the model were based on published sources; costs of Medicaid-funded sterilizations and Medicaid-covered births were based on data from the Medicaid Statistical Information System and The Guttmacher Institute, respectively. With the implementation of a revised Medicaid sterilization policy, we estimated that the number of fulfilled sterilization requests would increase by 45%, from 53.3% of all women having their sterilization requests fulfilled to 77.5%. Annually, this increase could potentially lead to over 29,000 unintended pregnancies averted and $215 million saved. A revised Medicaid sterilization policy could potentially honor women's reproductive decisions, reduce the number of unintended pregnancies and save a significant amount of public funds. Compared to the current federal Medicaid sterilization policy, a hypothetical, revised policy that reduces logistical barriers for women who desire publicly funded, postpartum sterilization could potentially avert over 29,000 unintended pregnancies annually and therefore lead to cost savings of $215 million each year. © 2013.

  12. A Molecular Method to Discriminate between Mass-Reared Sterile and Wild Tsetse Flies during Eradication Programmes That Have a Sterile Insect Technique Component.

    Directory of Open Access Journals (Sweden)

    Soumaïla Pagabeleguem

    2016-02-01

    Full Text Available The Government of Senegal has embarked several years ago on a project that aims to eradicate Glossina palpalis gambiensis from the Niayes area. The removal of the animal trypanosomosis would allow the development more efficient livestock production systems. The project was implemented using an area-wide integrated pest management strategy including a sterile insect technique (SIT component. The released sterile male flies originated from a colony from Burkina Faso.Monitoring the efficacy of the sterile male releases requires the discrimination between wild and sterile male G. p. gambiensis that are sampled in monitoring traps. Before being released, sterile male flies were marked with a fluorescent dye powder. The marking was however not infallible with some sterile flies only slightly marked or some wild flies contaminated with a few dye particles in the monitoring traps. Trapped flies can also be damaged due to predation by ants, making it difficult to discriminate between wild and sterile males using a fluorescence camera and / or a fluorescence microscope. We developed a molecular technique based on the determination of cytochrome oxidase haplotypes of G. p. gambiensis to discriminate between wild and sterile males. DNA was isolated from the head of flies and a portion of the 5' end of the mitochondrial gene cytochrome oxidase I was amplified to be finally sequenced. Our results indicated that all the sterile males from the Burkina Faso colony displayed the same haplotype and systematically differed from wild male flies trapped in Senegal and Burkina Faso. This allowed 100% discrimination between sterile and wild male G. p. gambiensis.This tool might be useful for other tsetse control campaigns with a SIT component in the framework of the Pan-African Tsetse and Trypanosomosis Eradication Campaign (PATTEC and, more generally, for other vector or insect pest control programs.

  13. Radio sterilized human ligaments and their clinical application

    International Nuclear Information System (INIS)

    Luna Z, D.; Reyes F, M. L.; Diaz M, I.; Hernandez R, G.

    2009-10-01

    The ligaments are human tissues that are used in the transplantation area. A ligament is an anatomical structure in band form, composed by resistant fibers that connect the tissues that unite the bones with the articulations. In an articulation, the ligaments allow and facilitate the movement inside the natural anatomical directions, while it restricts those movements that are anatomically abnormal, impeding lesions that could arise of this type of movements. The kneecap ligament is a very important tissue in the knee mobility and of walking in the human beings. This ligament can injure it because of automobile accidents, for sport lesions or illnesses, and in many cases the only form of recovering the knee movement is carried out a transplant with the purpose of replacing the damage ligament by allo gen kneecap ligament processed in specialized Tissue Banks where the tissue is sterilized with gamma radiation of 60 Co at very low temperatures, obtaining high quality ligaments for clinical application in injured patients. The kneecap ligaments are processed in the Tissue Banks with a segment of kneecap bone, a segment of tibial bone, the contained ligament between both bones and in some cases a fraction of the quadriceps tendon. In this work is given a description of the selection method of the tissue that includes the donor's serologic control, the kneecap ligament processing in the Radio Sterilized Tissues Bank, its sterilization with gamma radiation of 60 Co, also it is indicated like the clinical application of the allo gen ligament was realized in a hasty patient and whose previous crossed ligament was injured. Finally the results are presented from the tissue obtaining until the clinical application of it is, and in this case is observed a favorable initial evolution of the transplantation patient. (Author)

  14. Distinguishing Dirac/Majorana sterile neutrinos at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Claudio O. [Univ. Tecnica Federico Santa Maria, Valparaiso (Chile). CCTVal y Dept. of Physics; Kim, C.S. [Yonsei Univ., Seoul (Korea, Republic of). Dept. of Physics and IPAP; Wang, Kechen [Chinese Academy of Sciences, Beijing (China). Inst. of High Energy Physics; Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Zhang, Jue [Chinese Academy of Sciences, Beijing (China). Inst. of High Energy Physics

    2016-06-15

    We study the purely leptonic decays of W{sup ±} → e{sup ±}e{sup ±}μ{sup -+}ν and μ{sup ±}μ{sup ±}e{sup -+}ν produced at the LHC, induced by sterile neutrinos with mass m{sub N} below M{sub W} in the intermediate state. Since the final state neutrino escapes detection, one cannot tell whether this process violates lepton number, what would indicate a Majorana character for the intermediate sterile neutrino. Our study shows that when the sterile neutrino mixings with electrons and muons are different enough, one can still discriminate between the Dirac and Majorana character of this intermediate neutrino by simply counting and comparing the above decay rates. After performing collider simulations and statistical analysis, we find that at the 14 TeV LHC with an integrated luminosity of 3000 fb{sup -1}, for two benchmark scenarios m{sub N}=20 GeV and 50 GeV, at least a 3σ level of exclusion on the Dirac case can be achieved for disparities as mild as e.g. vertical stroke U{sub Ne} vertical stroke {sup 2}<0.7 vertical stroke U{sub Nμ} vertical stroke {sup 2} or vertical stroke U{sub Nμ} vertical stroke {sup 2}<0.7 vertical stroke U{sub Ne} vertical stroke {sup 2}, provided that vertical stroke U{sub Ne} vertical stroke {sup 2}, vertical stroke U{sub Nμ} vertical stroke {sup 2} are both above ∝2 x 10{sup -6}.

  15. Sterile neutrino, hidden dark matter and their cosmological signatures

    International Nuclear Information System (INIS)

    Das, Subinoy

    2012-01-01

    Though thermal dark matter has been the central idea behind the dark matter candidates, it is highly possible that dark matter of the universe is non-thermal in origin or it might be in thermal contact with some hidden or dark sector but not with standard model. Here we explore the cosmological bounds as well as the signatures on two types of non-thermal dark matter candidates. First we discuss a hidden dark matter with almost no interaction (or very feeble) with standard model particles so that it is not in thermal contact with visible sector but we assume it is thermalized with in a hidden sector due to some interaction. While encompassing the standard cold WIMP scenario, we do not require the freeze-out process to be non-relativistic. Rather, freeze-out may also occur when dark matter particles are semi-relativistic or relativistic. Especially we focus on the warm dark matter scenario in this set up and find the constraints on the warm dark matter mass, cross-section and hidden to visible sector temperature ratio which accounts for the observed dark-matter density, satisfies the Tremaine-Gunn bound on dark-matter phase space density and has a free-streaming length consistent with cosmological constraints on the matter power spectrum. Our method can also be applied to keV sterile neutrino dark matter which is not thermalized with standard model but is thermalized with in a dark sector. The second part of this proceeding focuses on an exotic dark matter candidate which arises from the existence of eV mass sterile neutrino through a late phase transition. Due to existence of a strong scalar force the light sterile states get trapped into stable degenerate micro nuggets. We find that its signature in matter power spectra is close to a warm dark matter candidate.

  16. Practical application of insect-parasitic nematodes and sterile flies

    International Nuclear Information System (INIS)

    Galle, F.; Loosjes, M.

    1987-01-01

    The company 'de Groene Vlieg' started with commercial control of the onion fly by means of the sterile insect technique. At the moment 10 per cent of the Dutch spring sown onions are treated with this method. The mass-rearing, the estimations of populations and the repeated releases of sterilized flies make it a rather complicated method. It can be applied economically per field, but only in areas with a concentration of onion growing. For export we see no possibilities yet. In principle the sterile insect technique can be applied also to other flies (carrot rust fly, cabbage root fly), but a suitable artificial diet is still lacking. Since some years we also rear the insect parasitic nematodes Heterorhabditis sp. and Neoaplectana bibionis. The later is experimentally used with success against Agrotis segetum caterpillars in lettuce. Research will yield more applications of nematodes against different pests. We use Heterorhabditis sp. in practice against the black vine weevil (Otiorhynchus sulcatus), a serious pest in glass houses, tree nurseries and gardens. Good control is achieved with a dose of one half to one million nematodes per square meter in moist soil and with temperatures above 12 degrees C. The application is similar to that of a chemical insecticide. The pest is killed by symbiontic bacteria, released by the nematodes after penetrating into the body cavity of the larvae. The nematodes are delivered by mail. If cooled they can be kept alive for over four weeks in the package. We export already to Switzerland and plan to export also to Western Germany. At this moment a possible admittance is under investigation in the Netherlands for application of a nuclear polyhedrosis virus against Spodoptera exigua caterpillars

  17. Research of tare hydrodynamic behaviour at sterilization of canned fish

    Directory of Open Access Journals (Sweden)

    Alexeev G. V.

    2016-09-01

    Full Text Available The paper is devoted to research on improving the equipment that ensures the absolute safety of mineral nutrients in the production of sterilized canned fish. The results of experimental study of hydrodynamic characteristics moving sterilized jars of canned fish of different sizes under the influence of circulating gas-liquid heat-carrying medium in the capacity have been presented. Some experimental setup with organized top-down and bottom-up flows in it modeling a sterilizer (autoclave has been proposed for the research. The experiments have been performed in the superficial gas velocity ranging from 0.03 m/s to 0.15 m/s corresponding to stable operation of the apparatus. Cans drag coefficient in the flow of heat-carrying medium has been determined by two methods for two heat-carrying media – pure glycerol and water solutions in experiments on precipitation and air – cans when blowing in the wind tunnel. The significant difference in the rates of cans upstream and downstream is reliably established, and therefore it has been proposed to use for the cans' motion characterization the indicator averaged over the two specified rates and called cans circulation speed. An empirical equation describing the dependence of the cans circulation rate from the superficial gas velocity has been obtained. Based on the analysis of studies some empirical dependencies on calculation of the drag coefficients of various types of packaging in the range of Reynolds criterion values from 1 to 4 000 have been offered. The necessity of using the qualifying factor for calculating the real drag on the results of the experiment has been determined.

  18. Design of good manufacturing facility for sterile radioactive pharmaceuticals

    International Nuclear Information System (INIS)

    Shin, B.C.; Choung, W.M.; Park, S.H.; Lee, K.I.; Park, J.H.; Park, K.B.

    2002-01-01

    Based on the GMP codes for radiopharmaceuticals in U.K. and some advanced countries, suitable guidelines for the production facility have been established and followed them up. The facility designs were fairly modified to maintain cleanliness criteria for installation in the existing radioisotope production facilities which are installed only in radiation safety points of view. Detailed design brief was drawn up by the Hyundai Engineering staffs, on the basis of initial planning and conceptual design was carried out by authors. Hot cells were installed in preparation room for radioactive handling. As hot cells under negative air pressure are not properly airtight, the surrounding environment was designed to keep less than class 10,000. Hot cells were designed to maintain less than class 1 0,000 and partially less than class 1 00 for production of sterile products. Final products will be autoclaved for sterilization after filling. To avoid contamination by microorganisms and particles of surrounding area, air curtain with vertical laminar flow will be installed between anteroom and corridor. In a pharmaceutical environment, the main consideration is the protection of the product. Thus, work station is held above ambient pressure. However, when handling radioactive materials, air pressure for work station should be lower than in surrounding areas to protect the operators and the remainder of the facility from airborne radioactive contamination. As Radiopharmaceuticals are radioactive materials for medical use, changing room could be held higher pressure than any other zones. It is expected that the facility will be effectively used for both routine preparation and research for sterile radiopharmaceuticals. (Author)

  19. Galaxy Formation in Sterile Neutrino Dark Matter Models

    Science.gov (United States)

    Menci, N.; Grazian, A.; Lamastra, A.; Calura, F.; Castellano, M.; Santini, P.

    2018-02-01

    We investigate galaxy formation in models with dark matter (DM) constituted by sterile neutrinos. Given their large parameter space, defined by the combinations of sterile neutrino mass {m}ν and mixing parameter {\\sin }2(2θ ) with active neutrinos, we focus on models with {m}ν =7 {keV}, consistent with the tentative 3.5 keV line detected in several X-ray spectra of clusters and galaxies. We consider (1) two resonant production models with {\\sin }2(2θ )=5 × {10}-11 and {\\sin }2(2θ )=2 × {10}-10, to cover the range of mixing parameters consistent with the 3.5 keV line; (2) two scalar-decay models, representative of the two possible cases characterizing such a scenario: a freeze-in and a freeze-out case. We also consider thermal warm DM with particle mass {m}X=3 {keV}. Using a semianalytic model, we compare the predictions for the different DM scenarios with a wide set of observables. We find that comparing the predicted evolution of the stellar mass function, the abundance of satellites of Milky Way–like galaxies, and the global star formation history of galaxies with observations does not allow us to disentangle the effects of the baryonic physics from those related to the different DM models. On the other hand, the distribution of the stellar-to-halo mass ratios, the abundance of faint galaxies in the UV luminosity function at z≳ 6, and the specific star formation and age distribution of local, low-mass galaxies constitute potential probes for the DM scenarios considered. We discuss how future observations with upcoming facilities will enable us to rule out or to strongly support DM models based on sterile neutrinos.

  20. Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus

    International Nuclear Information System (INIS)

    Chen Guochong; Liu Wen; Liu Qingfang

    2011-01-01

    The blood compatibility of the radiation sterilized disposable burette transfusion apparatus was investigated to provide evidence for the safety of radiation sterilized medical devices. The initial bacteria burden of the disposable burette transfusion apparatus was examined according to the ISO11737 standard, and the whole blood clotting time, prothrombin time, partial thromboplastin time and hemolysis rate of the samples were determined. There was no significant difference between the radiation sterilized samples and negative controls on WBCT, PT and PTT (p>0.05). Haemolysis test showed that the haemolysis rate of the sample sterilized by irradiation was 1.38%, which was coincidence with the criteria of the medical devices. After sterilization by irradiation, disposable burette transfusion apparatus show good blood compatibility, which could be considered that radiation sterilization is a biologically safe method for the medical apparatus. (authors)