WorldWideScience

Sample records for sterility wa-cms system

  1. An unedited 1.1 kb mitochondrial orfB gene transcript in the Wild Abortive Cytoplasmic Male Sterility (WA-CMS system of Oryza sativa L. subsp. indica

    Directory of Open Access Journals (Sweden)

    Maiti Mrinal K

    2010-03-01

    Full Text Available Abstract Background The application of hybrid rice technology has significantly increased global rice production during the last three decades. Approximately 90% of the commercially cultivated rice hybrids have been derived through three-line breeding involving the use of WA-CMS lines. It is believed that during the 21st century, hybrid rice technology will make significant contributions to ensure global food security. This study examined the poorly understood molecular basis of the WA-CMS system in rice. Results RFLPs were detected for atp6 and orfB genes in sterile and fertile rice lines, with one copy of each in the mt-genome. The RNA profile was identical in both lines for atp6, but an additional longer orfB transcript was identified in sterile lines. 5' RACE analysis of the long orfB transcript revealed it was 370 bp longer than the normal transcript, with no indication it was chimeric when compared to the genomic DNA sequence. cDNA clones of the longer orfB transcript in sterile lines were sequenced and the transcript was determined unedited. Sterile lines were crossed with the restorer and maintainer lines, and fertile and sterile F1 hybrids were respectively generated. Both hybrids contained two types of orfB transcripts. However, the long transcript underwent editing in the fertile F1 hybrids and remained unedited in the sterile lines. Additionally, the editing of the 1.1 kb orfB transcript co-segregated with fertility restoring alleles in a segregating population of F2 progeny; and the presence of unedited long orfB transcripts was detected in the sterile plants from the F2 segregating population. Conclusion This study helped to assign plausible operative factors responsible for male-sterility in the WA cytoplasm of rice. A new point of departure to dissect the mechanisms governing the CMS-WA system in rice has been identified, which can be applied to further harness the opportunities afforded by hybrid vigor in rice.

  2. Development of Cytoplasmic Male Sterile IR24 and IR64 Using CW-CMS/Rf17 System.

    Science.gov (United States)

    Toriyama, Kinya; Kazama, Tomohiko

    2016-12-01

    A wild-abortive-type (WA) cytoplasmic male sterility (CMS) has been almost exclusively used for breeding three-line hybrid rice. Many indica cultivars are known to carry restorer genes for WA-CMS lines and cannot be used as maintainer lines. Especially elite indica cultivars IR24 and IR64 are known to be restorer lines for WA-CMS lines, and are used as male parents for hybrid seed production. If we develop CMS IR24 and CMS IR64, the combination of F1 pairs in hybrid rice breeding programs will be greatly broadened. For production of CMS lines and restorer lines of IR24 and IR64, we employed Chinese wild rice (CW)-type CMS/Restorer of fertility 17 (Rf17) system, in which fertility is restored by a single nuclear gene, Rf17. Successive backcrossing and marker-assisted selection of Rf17 succeeded to produce completely male sterile CMS lines and fully restored restorer lines of IR24 and IR64. CW-cytoplasm did not affect agronomic characteristics. Since IR64 is one of the most popular mega-varieties and used for breeding of many modern varieties, the CW-CMS line of IR64 will be useful for hybrid rice breeding.

  3. Portable Decontamination and Sterilization System

    National Research Council Canada - National Science Library

    Bell, William; Smerjac, Suzanne; Smith, Bryan

    2004-01-01

    TDA Research, Inc., (TDA) is developing a portable system to generate chlorine dioxide, which can be used for biodecontamination of small items and to sterilize medical and dental instruments in austere environments...

  4. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene

    OpenAIRE

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-01-01

    Nuclear male sterility is common in flowering plants, but its application in hybrid breeding and seed production is limited because of the inability to propagate a pure male sterile line for commercial hybrid seed production. Here, we characterized a rice nuclear gene essential for sporophytic male fertility and constructed a male sterility system that can propagate the pure male sterile seeds on a large scale. This system is fundamentally advantageous over the current cytoplasmic male steril...

  5. Hysteroscopic tubal sterilization: a systematic review of the Essure system

    DEFF Research Database (Denmark)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika

    2010-01-01

    OBJECTIVE: To update the evidence of the efficacy and safety of the Essure system. Female sterilization has undergone changes in the last decade. Besides laparoscopic tubal occlusion, the Essure system is now a viable option, with about 200,000 women sterilized using this method. DESIGN: The review...... in ambulatory settings. However, sterilization is not immediate and women must use additional contraception for 3 months until permanent tubal occlusion is verified by transvaginal ultrasound, hysterosalpingosonography, hysterosalpingography, or pelvic radiography. The evidence on efficacy and safety is mainly...... sterilization, but more information on the total cost is needed. CONCLUSION(S): The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published...

  6. Hysteroscopic tubal sterilization: a systematic review of the Essure system.

    Science.gov (United States)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika; Grahn, Riitta; Kukkonen-Harjula, Katriina; Nord-Saari, Merja; Mäkelä, Marjukka

    2010-06-01

    To update the evidence of the efficacy and safety of the Essure system. Female sterilization has undergone changes in the last decade. Besides laparoscopic tubal occlusion, the Essure system is now a viable option, with about 200,000 women sterilized using this method. The review is based on the report of the Alberta Heritage Foundation for Medical Research and completed with systematic literature searches up to April 8, 2008. The Managed Uptake of Medical Methods program of the Finnish National Research and Development Center for Health and Welfare. Women over 30 years, who had been sterilized by the Essure method. Hysteroscopic tubal sterilization using Essure system. Efficacy/effectiveness, adverse events, costs. Sterilization by Essure can be performed under local anesthesia or with oral analgesics in ambulatory settings. However, sterilization is not immediate and women must use additional contraception for 3 months until permanent tubal occlusion is verified by transvaginal ultrasound, hysterosalpingosonography, hysterosalpingography, or pelvic radiography. The evidence on efficacy and safety is mainly available from short follow-up case series but shows good efficacy and safety of the Essure system. Only a few small risks are associated with the procedure. Two economic studies, one of which implemented Essure as an in-office procedure, suggest that Essure could be more cost-effective than laparoscopic sterilization, but more information on the total cost is needed. The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  7. Sterile Product Packaging and Delivery Systems.

    Science.gov (United States)

    Akers, Michael J

    2015-01-01

    Both conventional and more advanced product container and delivery systems are the focus of this brief article. Six different product container systems will be discussed, plus advances in primary packaging for special delivery systems and needle technology.

  8. Development and Validation of Sterility Systems for Trees

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, Steve; Shevchenko, Olga; Ma, Caiping (Cathleen)

    2007-03-30

    The overall goal of this project was to develop and validate sterility systems in poplar with the ultimate goal of fulfilling the basic requirements for commercial use. For this, sterility must be complete and stable over multiple growing seasons, cause no detrimental effects on vegetative growth, and successful transformation events must be identifiable via molecular tests when trees are still juvenile. Because of the inherent difficulties in achieving and demonstrating complete sterility in trees, our approach was to study alternate sterility systems in Arabidopsis and/or early-flowering tree systems. The public benefit from this work is the capacity for containment of genes or exotic forms of trees so they can be of benefit for industry for production of wood, energy, and renewable products, while having minimal impact on wild populations of trees. We tested three methods for engineering sterility: dominant negative mutant (DNM) proteins, floral tissue ablation, and RNA interference (RNAi) to suppress the expression of several floral regulatory genes. The ultimate goal of this work was to produce a number of transgenic poplars that could be outplanted to enable future assessments of the effectiveness of these transgenic sterility methods. Our attempts to produce ablation constructs that did not interfere with tree health were partially successful. Using the poplar LEAFY gene promoter and the barnase/barstar system, we were able to regenerate plants that grew well in the greenhouse, but they showed poor health in the field. Four of seven DNM genes tested were considered promising enough, based on results in Arabidopsis, to produce transgenic poplars. Single, double, and triple RNAi genes were produced and transformed into poplar. Over all, we produced 1,964 PCR-confirmed transgenic events with 19 different kinds of sterility genes and several kinds of control genes. We propagated 5,640, 6,820, and 7,055 trees for each of three test poplar genotypes, and field

  9. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene.

    Science.gov (United States)

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-12-06

    The breeding and large-scale adoption of hybrid seeds is an important achievement in agriculture. Rice hybrid seed production uses cytoplasmic male sterile lines or photoperiod/thermo-sensitive genic male sterile lines (PTGMS) as female parent. Cytoplasmic male sterile lines are propagated via cross-pollination by corresponding maintainer lines, whereas PTGMS lines are propagated via self-pollination under environmental conditions restoring male fertility. Despite huge successes, both systems have their intrinsic drawbacks. Here, we constructed a rice male sterility system using a nuclear gene named Oryza sativa No Pollen 1 (OsNP1). OsNP1 encodes a putative glucose-methanol-choline oxidoreductase regulating tapetum degeneration and pollen exine formation; it is specifically expressed in the tapetum and miscrospores. The osnp1 mutant plant displays normal vegetative growth but complete male sterility insensitive to environmental conditions. OsNP1 was coupled with an α-amylase gene to devitalize transgenic pollen and the red fluorescence protein (DsRed) gene to mark transgenic seed and transformed into the osnp1 mutant. Self-pollination of the transgenic plant carrying a single hemizygous transgene produced nontransgenic male sterile and transgenic fertile seeds in 1:1 ratio that can be sorted out based on the red fluorescence coded by DsRed Cross-pollination of the fertile transgenic plants to the nontransgenic male sterile plants propagated the male sterile seeds of high purity. The male sterile line was crossed with ∼1,200 individual rice germplasms available. Approximately 85% of the F1s outperformed their parents in per plant yield, and 10% out-yielded the best local cultivars, indicating that the technology is promising in hybrid rice breeding and production.

  10. Current systems of sterilization in the Philippines in both government and private hospitals

    International Nuclear Information System (INIS)

    Lim, L.E.

    1996-01-01

    In the Philippines, there are 1,700 registered hospitals, both private and government. There are 80,000 beds. The systems of sterilization are mainly using steam or to use ethylene oxide sterilization. Gamma ray sterilization is purely on experimental basis and very limited scale for industrial products. The author will trace the history of sterilization, practised since a century ago and trace back to the present system of sterilization. The principles applied, precautions and limitations or advantages of the different systems will be discussed particularly steam sterilization and ethylene oxide. Other forms of sterilization either chemical or physical will be discussed in passing. Experience in gamma ray sterilization in Japan and Australia will be presented when available data are obtained, to encourage local investors to engage in such venture. Philippines has been left behind by our neighbors. (author)

  11. Gamma-sterilization-induced radicals in biodegradable drug delivery systems

    International Nuclear Information System (INIS)

    Maeder, K.; Swartz, H.M.; Domb, A.

    1996-01-01

    Electron paramagnetic resonance (EPR) spectroscopy (1.2 and 9.25 GHz, 25 o C) was used to characterize free radicals in gamma-ray sterilized biodegradable polymers of the type which are in clinical use. Free radicals were detected in all irradiated polymer samples. The temperature of irradiation (25 o vs dry ice temperature) had only a minor influence on the yield of radicals and the shape of the EPR spectra. In contrast, the composition of the polymers and the drugs incorporated in them did strongly influence the amount of radiation-induced free radicals and their reactivity. In general, polymers with high melting points and crystallinity had the highest yields of radicals observable at room temperature. We were able to use the free radicals induced by the usual sterilization procedures to follow the penetration of water and the degradation of the polymers in vitro and in vivo. The ability of in vivo EPR to follow drug delivery noninvasively and continuously in vivo, using the free radicals induced in the usual sterilization process indicates that this approach could be applied immediately for the characterization of these drug delivery systems in experimental animals and in the near future should be able to be used in human subjects. (author)

  12. Practical fundamentals of glass, rubber, and plastic sterile packaging systems.

    Science.gov (United States)

    Sacha, Gregory A; Saffell-Clemmer, Wendy; Abram, Karen; Akers, Michael J

    2010-01-01

    Sterile product packaging systems consist of glass, rubber, and plastic materials that are in intimate contact with the formulation. These materials can significantly affect the stability of the formulation. The interaction between the packaging materials and the formulation can also affect the appropriate delivery of the product. Therefore, a parenteral formulation actually consists of the packaging system as well as the product that it contains. However, the majority of formulation development time only considers the product that is contained in the packaging system. Little time is spent studying the interaction of the packaging materials with the contents. Interaction between the packaging and the contents only becomes a concern when problems are encountered. For this reason, there are few scientific publications that describe the available packaging materials, their advantages and disadvantages, and their important product attributes. This article was created as a reference for product development and describes some of the packaging materials and systems that are available for parenteral products.

  13. Radiation sterilization

    International Nuclear Information System (INIS)

    Jacobs, G.P.

    1989-01-01

    In view of the application of ionizing radiation to sterilize pharmaceutical products, and the particular advantages of using this mode of sterilization for powders for injection, which cannot be sterilized by more conventional methods, it is important to recognise the possibility of modification of radiation response of bacteria when in close contact with various drug powders. For this study, bacterial spores, which lend themselves to dessication, and which can be dried onto an inert powder matrix, were chosen as the test system. The results of this work indicate that the additives tested have a modest protective effect on the spores. However, when considering a bacterial inactivation for sterilization purposes of between six and ten orders of magnitude, that is, a desired sterility assurance level of an expected maximum probability of a product item being non-sterile of 10 -6 , then the slight protective effect observed in this study approaches insignificance

  14. Discussion on the compilation of document of iso quality management system for radiation sterilization enterprises

    International Nuclear Information System (INIS)

    Li Chunhong; Ha Yiming; Zhou Hongjie; Feng Zhiguo; Wang Feng

    2006-01-01

    According to the character of cooperation of radiation sterilization, and association with request of ISO9001, ISO13485 and ISO11137, compilation of document in quality manual, procedure document and technological document during certification of ISO quality management system of cooperation of radiation sterilization was discussed. (authors)

  15. Transcervical Sterilization: A Comparison of Essure® Permanent Birth Control System and Adiana® Permanent Contraception System

    Science.gov (United States)

    Palmer, Sophia N; Greenberg, James A

    2009-01-01

    Transcervical sterilization has moved female sterilization from a minimally invasive laparoscopic technique, which requires entry into the abdominal cavity, to a less invasive hysteroscopic procedure. Along with the decreased potential for complications, its ease of performance with minimal anesthesia has facilitated a move from the operating room to the office. This review compares the available data on transcervical sterilization procedures to better understand the strengths and weakness of each system. PMID:19609402

  16. Workable male sterility systems for hybrid rice: Genetics, biochemistry, molecular biology, and utilization.

    Science.gov (United States)

    Huang, Jian-Zhong; E, Zhi-Guo; Zhang, Hua-Li; Shu, Qing-Yao

    2014-12-01

    The exploitation of male sterility systems has enabled the commercialization of heterosis in rice, with greatly increased yield and total production of this major staple food crop. Hybrid rice, which was adopted in the 1970s, now covers nearly 13.6 million hectares each year in China alone. Various types of cytoplasmic male sterility (CMS) and environment-conditioned genic male sterility (EGMS) systems have been applied in hybrid rice production. In this paper, recent advances in genetics, biochemistry, and molecular biology are reviewed with an emphasis on major male sterility systems in rice: five CMS systems, i.e., BT-, HL-, WA-, LD- and CW- CMS, and two EGMS systems, i.e., photoperiod- and temperature-sensitive genic male sterility (P/TGMS). The interaction of chimeric mitochondrial genes with nuclear genes causes CMS, which may be restored by restorer of fertility (Rf) genes. The PGMS, on the other hand, is conditioned by a non-coding RNA gene. A survey of the various CMS and EGMS lines used in hybrid rice production over the past three decades shows that the two-line system utilizing EGMS lines is playing a steadily larger role and TGMS lines predominate the current two-line system for hybrid rice production. The findings and experience gained during development and application of, and research on male sterility in rice not only advanced our understanding but also shed light on applications to other crops.

  17. Postpartum Sterilization

    Science.gov (United States)

    f AQ FREQUENTLY ASKED QUESTIONS FAQ052 CONTRACEPTION Postpartum Sterilization • What is sterilization? • What is postpartum sterilization? • How is postpartum sterilization performed? • What kind of anesthesia is used for postpartum sterilization? • How ...

  18. Study of fieldbus technology confiability when applied in a Sterilization plant control and safety systems

    International Nuclear Information System (INIS)

    Karma, D.; Sampa, M.H.O.; Rela, P.R.

    2001-01-01

    Several sterilization processes have been used in these years for treatment of countless products. Some processes use high temperatures, thermal shocks and chemical agents. With the discovery of the ionizing radiation and its posterior technological developments turned possible the application of that process, in 1960, also in the sterilization, denominated radiation sterilization. This process became also applied in another areas of health and industrial as food conservation, gemstones enhancement and others. The radiation sterilization requests an effective control and it needs a high level of safety. The commercial use of the computers applied in industrial automation provides and the domain of new technologies in this field provides news applications then new designs now is possible. The Fieldbus technology, a new digital communication protocol, like a Local Area Network, can be an alternative in the cobalt-60 irradiation plant. This paper show preliminary study about confiability in systems using Fieldbus technology. This technology was simulated in sterilization plant control and safety systems and the fail probability was quantified using Fail Tree Analysis Method. Fieldbus technology can be used in sterilization plants because the confiability in this systems is like PLCs and relays systems, was the conclusion

  19. Alcohol production from sterilized and non-sterilized molasses by Saccharomyces cerevisiae immobilized on brewer's spent grains in two types of continuous bioreactor systems

    International Nuclear Information System (INIS)

    Kopsahelis, Nikolaos; Bosnea, Loulouda; Bekatorou, Argyro; Tzia, Constantina; Kanellaki, Maria

    2012-01-01

    In this work an integrated cost effective system for continuous alcoholic fermentation of a cheap raw material (molasses) is described, involving yeast immobilized by a simple method on brewer's spent grains, able to ferment in the temperature range 30–40 °C, and two types of bioreactors, a Multistage Fixed Bed Tower (MFBT) and a Packed Bed reactor (PB). The MFBT bioreactor gave better results regarding ethanol concentration, productivity and conversion. Furthermore, the use of sterilized and non-sterilized molasses, fed in two similar MFBT bioreactors, showed that ethanol concentration (kg m −3 ) was significantly (p −3 at 35 °C and 44.2–48.2 kg m −3 at 40 °C), compared to sterilized molasses, where ethanol concentration ranged from 35.6 to 46.6 kg m −3 at 35 °C and 30.8–44.2 kg m −3 at 40 °C. During 32 days of continuous operation using non-sterilized molasses no contamination was observed. Industrialization of the proposed system seems to have a potential, mainly due to its high fermentation efficiency and the obtained high operational stability. -- Highlights: ► An integrated cost effective system for continuous alcoholic fermentation. ► Efficient conversion of non-sterilized molasses to ethanol. ► No need for additional treatments to prevent contamination. ► Results showed high fermentation efficiency and high operational stability.

  20. Effect of repeated sterilization by different methods on strength of carbon fiber rods used in external fixator systems.

    Science.gov (United States)

    Unal, Omer Kays; Poyanli, Oguz Sukru; Unal, Ulku Sur; Mutlu, Hasan Huseyin; Ozkut, Afsar Timucin; Esenkaya, Irfan

    2018-05-16

    We set out to reveal the effects of repeated sterilization, using different methods, on the carbon fiber rods of external fixator systems. We used a randomized set of forty-four unused, unsterilized, and identical carbon fiber rods (11 × 200 mm), randomly assigned to two groups: unsterilized (US) (4 rods) and sterilized (40 rods). The sterilized rods were divided into two groups, those sterilized in an autoclave (AC) and by hydrogen peroxide (HP). These were further divided into five subgroups based on the number of sterilization repetition to which the fibers were subjected (25-50-75-100-200). A bending test was conducted to measure the maximum bending force (MBF), maximum deflection (MD), flexural strength (FS), maximum bending moment (MBM) and bending rigidity (BR). We also measured the surface roughness of the rods. An increase in the number of sterilization repetition led to a decrease in MBF, MBM, FS, BR, but increased MD and surface roughness (p < 0.01). The effect of the number of sterilization repetition was more prominent in the HP group. This study revealed that the sterilization method and number of sterilization repetition influence the strength of the carbon fiber rods. Increasing the number of sterilization repetition degrades the strength and roughness of the rods.

  1. The Plasma Discharge System For Effective Sterilization Of Water And Solid Surfaces

    International Nuclear Information System (INIS)

    Senturk, K.

    2010-01-01

    The different areas such as medicine, surgery, food production need efficient sterilization system since they are directly related to human health. In this work a new plasma system is described in order to present its effectiveness in sterilization. This is a different method from conventional methods such as: chemicals and heat addition, UV irradiation etc. The developed plasma system produces cold plasma working under atmospheric pressure. To generate the plasma both AC and DC high voltage power supplies were used. The developed system is cheap and very effective for sterilization. The light emission for both AC and DC coronas for the plasmas were investigated to understand the nature of generated plasma ionization. Different parameters like temperature, voltage, application time were changed during the plasma application and the optimization for killing the micro-organisms were investigated. To understand the biological effect of plasma on the organisms comparisons were done by using the scanning electron microscope and absorption spectrometer. The plasma was applied on the bacteria like Escherichia coli, Bacillus subtilis, Streptococcus mutans , the yeasts such as Candida albicans, and green algae. The efficiency, the non toxic nature, the affordable price make this plasma discharge method a very efficient one for sterilization.

  2. Hysteroscopic Sterilization

    Science.gov (United States)

    ... sterilization? Sterilization is a permanent form of birth control. What is tubal sterilization? Sterilization procedures for women are ... is quicker than from other types of sterilization. What are the risks of ... on for birth control. • There is a risk of injury to the ...

  3. Modernization of safety system for the radiation facility for industrial sterilization

    International Nuclear Information System (INIS)

    Drndarevic, V.; Djuric, D.; Koturovic, A.; Arandjelovic, M.; Mikic, R.

    1995-01-01

    Modernization of the existing safety system of the radiation facility for industrial sterilization at the Vinca Institute of nuclear science is done. In order to improve radiation safety of the facility, the latest recommendations and requirements of IAEA have been implemented. Concept and design of the modernized system are presented. The new elements of the safety system are described and the improvements achieved by means of this modernization are pointed out. (author)

  4. Cleaning and sterilization in biotechnological clean system. Biotechnological clean system no senjo sakkin

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, M.

    1994-02-20

    Despite their usefulness for mankind, many of microorganisms are generally emphasized of the aspect of their harmfulness as decomposable and pathogenic microorganisms, apt to implant people with wrong preconception. Moreover, the food industries have a habitual practice that they leave unexpectedly unclean conditions unattended. This paper indicates such actual circumstances by quoting various examples, and introduces characteristics and test results on commercially available chemicals having excellent cleansing and sterilizing effects. High-pressure and high-temperature sterilization processes fit the purpose of preservation, but secondary contamination may occur in subsequent processing, for example, from the ceiling and walls of a work room, or operators' fingers. Problems exist there that should be considered in biotechnological clean systems. Technologies have been advanced that mix a small amount of chemicals into plastic sheets, wall materials, and floor materials so that their surfaces are kept away from growth of microorganisms for extended periods of time. About 300 kinds of chemicals have been developed, and are available commercially. 3 refs., 8 figs.

  5. A novel male sterility-fertility restoration system in plants for hybrid seed production.

    Science.gov (United States)

    Singh, Surendra Pratap; Singh, Sudhir P; Pandey, Tripti; Singh, Ram Rakshpal; Sawant, Samir V

    2015-06-15

    Hybrid seeds are used for stimulated crop production, as they harness heterosis. The achievement of complete male-sterility in the female-parent and the restored-fertility in F1-hybrids are the major bottlenecks in the commercial hybrid seed production. Here, we report a male sterility-fertility restoration system by engineering the in most nutritive anther wall layer tapetum of female and male parents. In the female parent, high-level, and stringent expression of Arabidopsis autophagy-related gene BECLIN1 was achieved in the tapetum, which altered the tapetal degeneration program, leading to male sterility. This works on our previously demonstrated expression cassette based on functional complementation of TATA-box mutant (TGTA) promoter and TATA-binding protein mutant3 (TBPm3), with modification by conjugating Long Hypocotyle in Far-Red1 fragment (HFR1(NT131)) with TBPm3 (HFR1(NT131)-TBPm3) to exercise regulatory control over it. In the male parent, tapetum-specific Constitutive photo-morphogenesis1 (COP1) was expressed. The F1 obtained by crossing these engineered parents showed decreased BECLIN1 expression, which was further completely abolished when COP1-mutant (COP1(L105A)) was used as a male parent, leading to normal tapetal development and restored fertility. The system works on COP1-HFR1 interaction and COP1-mediated degradation of TBPm3 pool (HFR1(NT131)-TBPm3). The system can be deployed for hybrid seed production in agricultural crops.

  6. A Study on the Application of UV Sterilization Method in HVAC System

    International Nuclear Information System (INIS)

    Cho, S. W.; Park, J. S.; Seo, I. W.; Lim, K. R.; An, W. S.; Oh, S. H.; Lee, K. W.; Kim, J. G.; Kwon, S. J.

    2005-04-01

    The objective of this report is to study on the application of UV sterilization method on HVAC system in building. One type of commercial UV lamp was utilized during this research. It was 1,050 mm length, 24.5 mm diameter, 65 w lamp output, single ended lamp intended for insertion into al frame from inside. Twenty six lamps were mounted and operated in cross flow. They were allowed to operate for at least 30 minutes prior to beginning each test. The test rig was operated at 2.5 m/s and 20 .deg. C, and the relatively humidity 21.6 %RH. The effect of UV sterilization are investigated that as the general virus about 94 %, the mold microbe about 64 % and the bacillus about 86 %, respectively. Following this report will be used important data for the design and manufacture of the UV

  7. A Study on the Application of UV Sterilization Method in HVAC System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, S. W.; Park, J. S.; Seo, I. W.; Lim, K. R.; An, W. S.; Oh, S. H.; Lee, K. W.; Kim, J. G.; Kwon, S. J

    2005-04-15

    The objective of this report is to study on the application of UV sterilization method on HVAC system in building. One type of commercial UV lamp was utilized during this research. It was 1,050 mm length, 24.5 mm diameter, 65 w lamp output, single ended lamp intended for insertion into al frame from inside. Twenty six lamps were mounted and operated in cross flow. They were allowed to operate for at least 30 minutes prior to beginning each test. The test rig was operated at 2.5 m/s and 20 .deg. C, and the relatively humidity 21.6 %RH. The effect of UV sterilization are investigated that as the general virus about 94 %, the mold microbe about 64 % and the bacillus about 86 %, respectively. Following this report will be used important data for the design and manufacture of the UV.

  8. Auditory display as feedback for a novel eye-tracking system for sterile operating room interaction.

    Science.gov (United States)

    Black, David; Unger, Michael; Fischer, Nele; Kikinis, Ron; Hahn, Horst; Neumuth, Thomas; Glaser, Bernhard

    2018-01-01

    The growing number of technical systems in the operating room has increased attention on developing touchless interaction methods for sterile conditions. However, touchless interaction paradigms lack the tactile feedback found in common input devices such as mice and keyboards. We propose a novel touchless eye-tracking interaction system with auditory display as a feedback method for completing typical operating room tasks. Auditory display provides feedback concerning the selected input into the eye-tracking system as well as a confirmation of the system response. An eye-tracking system with a novel auditory display using both earcons and parameter-mapping sonification was developed to allow touchless interaction for six typical scrub nurse tasks. An evaluation with novice participants compared auditory display with visual display with respect to reaction time and a series of subjective measures. When using auditory display to substitute for the lost tactile feedback during eye-tracking interaction, participants exhibit reduced reaction time compared to using visual-only display. In addition, the auditory feedback led to lower subjective workload and higher usefulness and system acceptance ratings. Due to the absence of tactile feedback for eye-tracking and other touchless interaction methods, auditory display is shown to be a useful and necessary addition to new interaction concepts for the sterile operating room, reducing reaction times while improving subjective measures, including usefulness, user satisfaction, and cognitive workload.

  9. The smart aerial release machine, a universal system for applying the sterile insect technique: Manuscript Draft

    International Nuclear Information System (INIS)

    Mubarqui, Leal Ruben; Perez, Rene Cano; Klad, Roberto Angulo; Lopez, Jose L. Zavale; Parker, Andrew; Seck, Momar Talla; Sall, Baba; Bouyer, Jeremy

    2014-01-01

    Beyond insecticides, alternative methods to control insect pests for agriculture and vectors of diseases are needed. Management strategies involving the mass-release of living control agents have been developed, including genetic control with sterile insects and biological control with parasitoids, for which aerial release of insects is often required. Aerial release in genetic control programmes often involves the use of chilled sterile insects, which can improve dispersal, survival and competitiveness of sterile males. Currently available means of aerially releasing chilled fruit flies are however insufficiently precise to ensure homogeneous distribution at low release rates and no device is available for tsetse. Here we present the smart aerial release machine, a new design by the Mubarqui Company, based on the use of vibrating conveyors. The machine is controlled through Bluetooth by a tablet with Android Operating System including a completely automatic guidance and navigation system (MaxNav software). The tablet is also connected to an online relational database facilitating the preparation of flight schedules and automatic storage of flight reports. The new machine was compared with a conveyor release machine in Mexico using two fruit flies species (Anastrepha ludens and Ceratitis capitata) and we obtained better dispersal homogeneity (% of positive traps, p < 0.001) for both species and better recapture rates for Anastrepha ludens (p < 0.001), especially at low release densities (<1500 per ha). We also demonstrated that the machine can replace paper boxes for aerial release of tsetse in Senegal.This technology limits damages to insects and allows a large range of release rates from 10 flies/km"2 for tsetse flies up to 600 000 flies/km"2 for fruit flies. The potential of this machine to release other species like mosquitoes is discussed. Plans and operating of the machine are provided to allow its use worldwide.

  10. The smart aerial release machine, a universal system for applying the sterile insect technique.

    Directory of Open Access Journals (Sweden)

    Ruben Leal Mubarqui

    Full Text Available Beyond insecticides, alternative methods to control insect pests for agriculture and vectors of diseases are needed. Management strategies involving the mass-release of living control agents have been developed, including genetic control with sterile insects and biological control with parasitoids, for which aerial release of insects is often required. Aerial release in genetic control programmes often involves the use of chilled sterile insects, which can improve dispersal, survival and competitiveness of sterile males. Currently available means of aerially releasing chilled fruit flies are however insufficiently precise to ensure homogeneous distribution at low release rates and no device is available for tsetse.Here we present the smart aerial release machine, a new design by the Mubarqui Company, based on the use of vibrating conveyors. The machine is controlled through Bluetooth by a tablet with Android Operating System including a completely automatic guidance and navigation system (MaxNav software. The tablet is also connected to an online relational database facilitating the preparation of flight schedules and automatic storage of flight reports. The new machine was compared with a conveyor release machine in Mexico using two fruit flies species (Anastrepha ludens and Ceratitis capitata and we obtained better dispersal homogeneity (% of positive traps, p<0.001 for both species and better recapture rates for Anastrepha ludens (p<0.001, especially at low release densities (<1500 per ha. We also demonstrated that the machine can replace paper boxes for aerial release of tsetse in Senegal.This technology limits damages to insects and allows a large range of release rates from 10 flies/km2 for tsetse flies up to 600,000 flies/km2 for fruit flies. The potential of this machine to release other species like mosquitoes is discussed. Plans and operating of the machine are provided to allow its use worldwide.

  11. Chilled packing systems for fruit flies (Diptera: Tephritidae) in the sterile insect technique

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Emilio; Escobar, Arseny; Bravo, Bigail; Montoya, Pablo [Instituto Interamericano de Cooperacion para la Agricultura (IICA), Chiapas (Mexico); Secretaria de Agricultura, Ganaderia, Desarrollo Rural, Pesca y Alimentacion (SAGARPA), Mexico, D.F. (Mexico). Programa Moscafrut

    2010-07-15

    We evaluated three packing systems (PARC boxes, 'GT' screen towers and 'MX' screen towers) for the emergence and sexual maturation of sterile fruit flies, at three adult fl y densities (1, 1.2 and 1.3 fly/cm 2) and three food types. At the lowest density, results showed no significant differences in the longevity and flight ability of adult Anastrepha ludens (Loew) and Anastrepha obliqua Macquart among the three packing systems. Higher densities resulted in a decrease in these parameters. In the evaluation of the three food types, no significant differences were found either on longevity or flight ability of A. ludens. However, the greatest longevity for both sexes A. obliqua was obtained with commercial powdered Mb and the mix of sugar, protein and corn starch on paper (SPCP) food types. The highest value for flight ability in A. obliqua males was obtained with powdered Mb and SPCP food types, and for females with Mb powdered food. Our data indicated that GT and MX screen tower packing systems are an alternative to the PARC boxes, since they were suitable for adult fl y sexual maturation without any harm to their longevity or flight ability. The tested foods were equivalent in both fruit fl y species, with the exception of the agar type for A. obliqua, which yielded the lowest biological parameters evaluated. Our results contribute to the application of new methods for the packing and release of sterile flies in large-scale programs. (author)

  12. Chilled packing systems for fruit flies (Diptera: Tephritidae) in the sterile insect technique

    International Nuclear Information System (INIS)

    Hernandez, Emilio; Escobar, Arseny; Bravo, Bigail; Montoya, Pablo; Secretaria de Agricultura, Ganaderia, Desarrollo Rural, Pesca y Alimentacion

    2010-01-01

    We evaluated three packing systems (PARC boxes, 'GT' screen towers and 'MX' screen towers) for the emergence and sexual maturation of sterile fruit flies, at three adult fl y densities (1, 1.2 and 1.3 fly/cm 2) and three food types. At the lowest density, results showed no significant differences in the longevity and flight ability of adult Anastrepha ludens (Loew) and Anastrepha obliqua Macquart among the three packing systems. Higher densities resulted in a decrease in these parameters. In the evaluation of the three food types, no significant differences were found either on longevity or flight ability of A. ludens. However, the greatest longevity for both sexes A. obliqua was obtained with commercial powdered Mb and the mix of sugar, protein and corn starch on paper (SPCP) food types. The highest value for flight ability in A. obliqua males was obtained with powdered Mb and SPCP food types, and for females with Mb powdered food. Our data indicated that GT and MX screen tower packing systems are an alternative to the PARC boxes, since they were suitable for adult fl y sexual maturation without any harm to their longevity or flight ability. The tested foods were equivalent in both fruit fl y species, with the exception of the agar type for A. obliqua, which yielded the lowest biological parameters evaluated. Our results contribute to the application of new methods for the packing and release of sterile flies in large-scale programs. (author)

  13. Construction of a multicontrol sterility system for a maize male-sterile line and hybrid seed production based on the ZmMs7 gene encoding a PHD-finger transcription factor.

    Science.gov (United States)

    Zhang, Danfeng; Wu, Suowei; An, Xueli; Xie, Ke; Dong, Zhenying; Zhou, Yan; Xu, Liwen; Fang, Wen; Liu, Shensi; Liu, Shuangshuang; Zhu, Taotao; Li, Jinping; Rao, Liqun; Zhao, Jiuran; Wan, Xiangyuan

    2018-02-01

    Although hundreds of genetic male sterility (GMS) mutants have been identified in maize, few are commercially used due to a lack of effective methods to produce large quantities of pure male-sterile seeds. Here, we develop a multicontrol sterility (MCS) system based on the maize male sterility 7 (ms7) mutant and its wild-type Zea mays Male sterility 7 (ZmMs7) gene via a transgenic strategy, leading to the utilization of GMS in hybrid seed production. ZmMs7 is isolated by a map-based cloning approach and encodes a PHD-finger transcription factor orthologous to rice PTC1 and Arabidopsis MS1. The MCS transgenic maintainer lines are developed based on the ms7-6007 mutant transformed with MCS constructs containing the (i) ZmMs7 gene to restore fertility, (ii) α-amylase gene ZmAA and/or (iii) DNA adenine methylase gene Dam to devitalize transgenic pollen, (iv) red fluorescence protein gene DsRed2 or mCherry to mark transgenic seeds and (v) herbicide-resistant gene Bar for transgenic seed selection. Self-pollination of the MCS transgenic maintainer line produces transgenic red fluorescent seeds and nontransgenic normal colour seeds at a 1:1 ratio. Among them, all the fluorescent seeds are male fertile, but the seeds with a normal colour are male sterile. Cross-pollination of the transgenic plants to male-sterile plants propagates male-sterile seeds with high purity. Moreover, the transgene transmission rate through pollen of transgenic plants harbouring two pollen-disrupted genes is lower than that containing one pollen-disrupted gene. The MCS system has great potential to enhance the efficiency of maize male-sterile line propagation and commercial hybrid seed production. © 2017 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.

  14. Sterile neutrino

    International Nuclear Information System (INIS)

    Anon.

    2007-01-01

    Paper deals with the information on the occurrence of the fields of the sterile neutrinos (the righthanded ones) mixed with the normal neutrinos (the lefthanded ones). Both the Max Plank Radioastronomy Institute and the Los Angeles University assumes that the occurrence of the keV mass sterile neutrinos may explain the dark matter nature, the fast rotation of the observed pulsars and the reionization processes. The issues associated with the possibility to record the sterile neutrinos were analyzed in the course of the Sterile Neutrinos in Astrophysics and Cosmology Workshop (Crans Montana, March 2006 [ru

  15. A hydroponic system for growing gnotobiotic vs. sterile plants to study phytoremediation processes.

    Science.gov (United States)

    Kurzbaum, E; Kirzhner, F; Armon, R

    2014-01-01

    In some phytoremediation studies it is desirable to separate and define the specific contribution of plants and root-colonizing bacteria towards contaminant removal. Separating the influence of plants and associated bacteria is a difficult task for soil root environments. Growing plants hydroponically provides more control over the biological factors in contaminant removal. In this study, a hydroponic system was designed to evaluate the role of sterile plant roots, rhizodeposition, and root-associated bacteria in the removal of a model contaminant, phenol. A strain of Pseudomonas pseudoalcaligenes that grows on phenol was inoculated onto plant roots. The introduced biofilm persisted in the root zone and promoted phenol removal over non-augmented controls. These findings indicate that this hydroponic system can be a valuable tool for phytoremediation studies that investigate the effects of biotic and abiotic factors on pollution remediation.

  16. Fate of Staphylococcus aureus in radiation sterilized model food systems simulating dairy products

    International Nuclear Information System (INIS)

    Sulebele, G.A.; Kamat, M.Y.

    1976-01-01

    Gamma irradiation was successfully employed for the development of sterile model food systems simulating dairy products such as pedha and cottage cheese which were inoculated with enterotoxigenic S.aureus S-6 and FR1-100 either individually or in association with S.epidermids and other mixed flora comprising of gram-positive, gram-negative and lactic bacteria and stored at 4 and 35 degC for 6-8 weeks. Pedha failed to support growth of S.aureus while cottage cheese favoured profuse growth of the pathogen. S.epidermidis exhibited a synergistic effect on the growth of S.aureus in cottage cheese. Baired-Parker's medium showed very poor recovery of S.aureus which necessitated the development of a new selective medium for the enumeration of staphylococci in processed foods. (author)

  17. Validation of the efficacy of a solar-thermal powered autoclave system for off-grid medical instrument wet sterilization.

    Science.gov (United States)

    Kaseman, Tremayne; Boubour, Jean; Schuler, Douglas A

    2012-10-01

    This work describes the efficacy of a solar-thermal powered autoclave used for the wet sterilization of medical instruments in off-grid settings where electrical power is not readily available. Twenty-seven trials of the solar-thermal powered system were run using an unmodified non-electric autoclave loaded with a simulated bundle of medical instruments and biological test agents. Results showed that in 100% of the trials the autoclave achieved temperatures in excess of 121°C for 30 minutes, indicator tape displayed visible reactions to steam sterilization, and biological tests showed that microbial agents had been eliminated, in compliance with the Centers for Disease Control and Prevention requirements for efficacious wet sterilization.

  18. Sterilization efficacy of ultraviolet irradiation on microbial aerosols under dynamic airflow by experimental air conditioning systems

    International Nuclear Information System (INIS)

    Nakamura, Hiroshi

    1987-01-01

    In order to know the sterilization efficacy of ultraviolet irradiation on microbial aerosols, the size and the weight of the aerosol particles were evaluated, and these were irradiated under dynamic air flow created by an experimental air conditioning system. The experimental apparatus consisted of a high efficiency particulate air (HEPA) filter, an aerosol generator, spiral UV lamps placed around a quart glass tube, an Andersen air sampler and a vacuum pump. They were connected serially by stainless steel ducts (85 mm in diameter, 8 m in length). Six types of microbial aerosols generated from an ultrasonic nebulizer were irradiated by UV rays (wavelength 254 nm, mean density 9400 μW/cm 2 ). Their irradiation time ranged from 1.0 to 0.0625 seconds. The microbial aerosols were collected onto the trypticase soy agar (TSA) medium in the Andersen air sampler. After incubation, the number of colony forming units (CFU) were counted, and converted to particle counts. The diameter of microbial aerosol particles calculated by their log normal distribution were found to match the diameter of a single bacteria cell measured by a microscope. The sterilization efficacy of UV in standard airflow conditions (0.5 sec. irradiation) were found to be over 99.5 % in Staphylococcus aureus, Staphylococcus epidermidis, Serratia marcescens, Bacillus subtilis (vegetative cell) and Bacillus subtilis (spore) and 67 % in Aspergillus niger (conidium). In A. niger, which was the most resistant microbe to UV irradiation, the efficacy rose up to 79 % when irradiated for 1.0 sec., and it was observed that the growth speed of the colonies was slower than that of the controls. It was thought that UV rays caused some damage to the proliferation of A. niger cells. (author)

  19. LED surgical lighting system with multiple free-form surfaces for highly sterile operating theater application.

    Science.gov (United States)

    Liu, Peng; Zhang, Yaqin; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-06-01

    Although the ventilation system is widely employed in the operating theater, a strictly sterile surgical environment still cannot be ensured because of laminar disturbance, which is mainly caused by the surgical lighting system. Abandoning traditional products, we propose an LED surgical lighting system, which can alleviate the laminar disturbance and provide an appropriate lighting condition for surgery. It contains a certain amount of LED lens units, which are embedded in the ceiling and arranged around the air supply smallpox. The LED lens unit integrated with an LED light source and a free-form lens is required to produce a uniform circular illumination with a large tolerance to the change of lighting distance. To achieve such a dedicated lens, two free-form refractive surfaces, which are converted into two ordinary differential equations by the design method presented in this paper, are used to deflect the rays. The results show that the LED surgical lighting system can provide an excellent illumination environment for surgery, and, apparently, the laminar disturbance also can be relieved.

  20. Studies on the male sterility-fertility restoration system of AE. Kotschyi 19

    International Nuclear Information System (INIS)

    Cheng Junyuan; Sun Guoqing; Liu Luxiang; Zhao Linshu; Lu Xiuxia

    1996-01-01

    Sterile plants were obtained from the distant hybridization between Ae. Kotschyi 19 as the female parent and the Chinese Spring and T. yunnanense King as the male parent. Common wheat lines were used to testcross and backcross with the F 1 sterile plants successively. Male sterile line K-19 with Ae. Kotschyi cytoplasm and common wheat nucleus was bred. Over 10 K-19 MS lines were obtained. They are steady without monoploid. 7 restorers were obtained with the restoring ability from 88.2% to 96.9% according to the domestic method, from 116.4% to 150.4% according to the international method

  1. Auditing radiation sterilization facilities

    Science.gov (United States)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  2. Evolvement of transgenic male-sterility and fertility-restoration system in rice for production of hybrid varieties.

    Science.gov (United States)

    Rao, Gundra Sivakrishna; Deveshwar, Priyanka; Sharma, Malini; Kapoor, Sanjay; Rao, Khareedu Venkateswara

    2018-01-01

    We have developed a unique male-sterility and fertility-restoration system in rice by combining Brassica napus cysteine-protease gene (BnCysP1) with anther-specific P12 promoter of rice for facilitating production of hybrid varieties. In diverse crop plants, male-sterility has been exploited as a useful approach for production of hybrid varieties to harness the benefits of hybrid vigour. The promoter region of Os12bglu38 gene of rice has been isolated from the developing panicles and was designated as P12. The promoter was fused with gusA reporter gene and was expressed in Arabidopsis and rice systems. Transgenic plants exhibited GUS activity in tapetal cells and pollen of the developing anthers indicating anther/pollen-specific expression of the promoter. For engineering nuclear male sterility, the coding region of Brassica napus cysteine protease1 (BnCysP1) was isolated from developing seeds and fused to P12 promoter. Transgenic rice plants obtained with P12-BnCysP1 failed to produce functional pollen grains. The F 1 seeds obtained from BnCysP1 male-sterile plants and untransformed controls showed 1:1 (tolerant:sensitive) ratio when germinated on the MS medium supplemented with phosphinothricin (5 mg/l), confirming that the male sterility has been successfully engineered in rice. For male fertility restoration, transgenic rice plants carrying BnCysP1Si silencing system were developed. The pollination of BnCysP1 male-sterile (female-fertile) plants with BnCysP1Si pollen resulted in normal grain filling. The F 1 seeds of BnCysP1 × BnCysP1Si when germinated on the MS basal medium containing PPT (5 mg/l) and hygromycin (70 mg/l) exhibited 1:1 (tolerant:sensitive) ratio and the tolerant plants invariably showed normal grain filling. The overall results clearly suggest that the customized male-sterility & fertility-restoration system can be exploited for quality hybrid seed production in various crops.

  3. Study of fieldbus technology applied in a sterilization plant control and safety systems

    International Nuclear Information System (INIS)

    Karam Junior, Dib

    2000-01-01

    Several sterilization processes have been used in these years for treatment of countless products. Some processes use high temperatures, thermal shocks and chemical agents. With the discovery of the ionizing radiation and its posterior technological developments turned possible application of that process, in 1960, also in the the sterilization, denominated radiation sterilization. This process became also applied in another areas of health and industrial as food conservation, gemstones enhancement and others. The radiation sterilization requests an effective control and it needs a high level of safety. The commercial use of the computers applied in industrial automation provides and the domain of new technologies in this field provides new applications then new designs now is possible. The Fieldbus technology, a new digital communication protocol, like a Local Area Network, can be an alternative in the cobalt-60 irradiation plant. The present work suggests, evaluates, qualifies and quantifies this possibility. (author)

  4. Quality management systems for fruit fly (Diptera: Tephritidae) sterile insect technique

    International Nuclear Information System (INIS)

    Caceres, C.; Robinson, A.; McInnis, D.; Shelly, T.; Jang, E.; Hendrichs, J.

    2007-01-01

    The papers presented in this issue are focused on developing and validating procedures to improve the overall quality of sterile fruit flies for use in area-wide integrated pest management (AW-IPM) programs with a sterile insect technique (SIT) component. The group was coordinated and partially funded by the Joint FAO/IAEA Programme of Nuclear Techniques in Food and Agriculture, International Atomic Energy Agency, Vienna, Austria, under a five-year Coordinated Research Project (CRP) on 'Quality Assurance in Mass-Reared and Released Fruit Flies for Use in SIT Programmes'. Participants in the CRP from 16 countries came from both basic and applied fields of expertise to ensure that appropriate and relevant procedures were developed. A variety of studies was undertaken to develop protocols to assess strain compatibility and to improve colonization procedures and strain management. Specific studies addressed issues related to insect nutrition, irradiation protocols, field dispersal and survival, field cage behavior assessments, and enhancement of mating competitiveness. The main objective was to increase the efficiency of operational fruit fly programs using sterile insects and to reduce their cost. Many of the protocols developed or improved during the CRP will be incorporated into the international quality control manual for sterile tephritid fruit flies, standardizing key components of the production, sterilization, shipment, handling, and release of sterile insects. (author) [es

  5. Medfly (Ceratitis capitata Wiedemann) female attractant studies and development of trapping systems for sterility assessment

    International Nuclear Information System (INIS)

    Vasquez, L.A.; Sponagel, K.

    1999-01-01

    In four years of research, we evaluated different traps (McPhail, Tephri, Closed-bottom dry trap, Open-bottom dry trap, and Frutect), lures (FA-2 and FA-3 synthetic lures composed of ammonium acetate + putrescine, and ammonium acetate + putrescine + trimethylamine, respectively), and insect retention methods (water, sticky inserts, insecticides) to develop a selective trapping system for female Mediterranean fruit fly (Ceratitis capitata, Wiedemann) sterility assessment. The trapping systems were compared with protein-baited McPhail traps, which are the standard method for C. capitata female capture, during eight to fifteen week trials in coffee and orthanique orange plantations at two different localities in Honduras. Trimedlure-baited Jackson traps were also used as the standard indicator of the C. capitata populations. The Closed-bottom trap baited with the two-component synthetic lure captured eight to twelve times fewer C. capitata than the Jackson trap. The McPhail trap and the modified Open-bottom trap, both baited with the two-component synthetic lure, captured 1.6 to 3.5 times more C. capitata females than the protein-baited McPhail trap. The addition of trimethylamine to the two-component synthetic lure resulted in 9.8 to 15.8 times increases in C. capitata female capture over the protein-baited McPhail trap. The presence of water in McPhail or Tephri traps did not affect the capture of C. capitata females. Throughout the study, all female-targeted trapping systems captured the same proportion of females. (author)

  6. Validation of radiation sterilization process

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    The standards for quality management systems recognize that, for certain processes used in manufacturing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product. Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of sterilization process is monitored routinely and the equipment is maintained according to ISO 13 485. Different aspects of this norm are presented

  7. Male sterility in chestnuts

    International Nuclear Information System (INIS)

    Omura, Mitsuo; Akihama, Tomoya

    1982-01-01

    A tentative plan was proposed for chestnuts based on their pollination system, male sterility and restoration. The studies on the male sterility of 1,063 cultivars and clones suggested that there were three types of male sterility. The first type (S-1) was characterized by antherless florets. In the second type (S-2), the catkins fell before anthesis, and the third type (S-3) appeared to develop normally in gross floral morphology, but the pollen grains were abnormal in shape and did not have germinating power. In an interspecific hybrid clone CS which belonged to S-1, fertility was restored in an open pollinated progeny. The use of CS and CSO-3 with its restored fertility, permitted the planning of breeding the chestnut hybrid cultivars propagated by seeds. The inbred clones with either male sterility or restorer genes are first bred mainly by back crossing with parents with favorable pollen. The clones are selected individually for early bearing, wasp and disease resistance, and restoration. Then, the hybrid seedling lines between male sterile and restorer inbreds are evaluated for homogenity in nut characters and tree habits. Next, the hybrid seedling lines selected will be examined for crop yield, vigor and cross compatibility. The superior seedling lines are finally selected, and the parental inbreds are grafted to be propagated for seed production orchards. (Kaihara, S.)

  8. Development of female medfly attractant systems for trapping and sterility assessment. Proceedings of a final research co-ordination meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Practical application of the sterile insect technique (SIT) against major insect pests will continue to increase as the repeated use of insecticides is recognized as an environmental problem. In the case of the Mediterranean fruit fly (medfly), which attacks over 300 species of fruits and vegetables in tropical, subtropical, and temperate climates on all five continents, control is still largely based on frequent insecticide spraying, often more than 10 sprays per fruiting season. Methods for population estimation, which accurately reflect changes due to movement, mortality or reproduction, are a prerequisite for effective pest management and in particular for use of SIT. With better monitoring tools medfly populations can be estimated more accurately and compared under different conditions, to guide decisions on alternative (i.e. more effective and more environment-friendly) control strategies. In support of this need in the application of SIT field programmes against medfly, an FAO/IAEA co-ordinated research project (CRP) was carried out which resulted in a TECDOC published in 1996 on Standardization of Medfly Trapping for Use in sterile insect technique Programmes. Following the development of male only genetic sexing strains at the FAO/IAEA Agriculture and Biotechnology Laboratories in Seibersdorf, Austria, it was recognized that the development of a female medfly targeted trapping system, in conjunction with only male sterile releases, would improve the efficacy of the SIT, reduce costs, and more effectively utilize sterile males. As a result, a new FAO/IAEA Co-ordinated Research Project on Development of Female Medfly Attractant Systems for Trapping and Sterility Assessment was initiated in 1994 with the objective to develop new synthetic female medfly attractants and to determine their efficacy compared to proteinaceous baits under different weather, host-tree and population density conditions. Findings obtained during the course of this 5-year CRP are

  9. Development of female medfly attractant systems for trapping and sterility assessment. Proceedings of a final research co-ordination meeting

    International Nuclear Information System (INIS)

    1999-07-01

    Practical application of the sterile insect technique (SIT) against major insect pests will continue to increase as the repeated use of insecticides is recognized as an environmental problem. In the case of the Mediterranean fruit fly (medfly), which attacks over 300 species of fruits and vegetables in tropical, subtropical, and temperate climates on all five continents, control is still largely based on frequent insecticide spraying, often more than 10 sprays per fruiting season. Methods for population estimation, which accurately reflect changes due to movement, mortality or reproduction, are a prerequisite for effective pest management and in particular for use of SIT. With better monitoring tools medfly populations can be estimated more accurately and compared under different conditions, to guide decisions on alternative (i.e. more effective and more environment-friendly) control strategies. In support of this need in the application of SIT field programmes against medfly, an FAO/IAEA co-ordinated research project (CRP) was carried out which resulted in a TECDOC published in 1996 on Standardization of Medfly Trapping for Use in sterile insect technique Programmes. Following the development of male only genetic sexing strains at the FAO/IAEA Agriculture and Biotechnology Laboratories in Seibersdorf, Austria, it was recognized that the development of a female medfly targeted trapping system, in conjunction with only male sterile releases, would improve the efficacy of the SIT, reduce costs, and more effectively utilize sterile males. As a result, a new FAO/IAEA Co-ordinated Research Project on Development of Female Medfly Attractant Systems for Trapping and Sterility Assessment was initiated in 1994 with the objective to develop new synthetic female medfly attractants and to determine their efficacy compared to proteinaceous baits under different weather, host-tree and population density conditions. Findings obtained during the course of this 5-year CRP are

  10. 1 1/2 years of experience with a 10 MeV self-shielded on-line e-beam sterilization system

    International Nuclear Information System (INIS)

    Lambert, Byron; Tang, Fuh-Wei; Riggs, Brian; Allen, Thomas; Williams, C.B.

    2000-01-01

    The Vascular Intervening Group of the Guidant Corporation (Guidant IV) has been operating a self-shielded, 10 MeV 4 kW, electron beam sterilization system since July of 1988. The system was designed, built and installed in a 70 square meter area in an existing Guidant manufacturing facility by Titan Scan Corporation and performance of the system was validated in conformance with 1S0-11137 standards. The goal of this on-site e-beam system was 'just in time' JIT, sterilization, i.e. the ability to manufacture, sterilize and ship, high intrinsic value medical devices in less than 24 hours. The benefits of moving from a long gas sterilization cycle of greater than one week to a JIT process were envisioned to be a) speed to market with innovated new products b) rapid response to customer requirements c) reduced inventory carrying costs and finally manufacturing and quality system efficiency. The ability of Guidant to realize these benefits depended upon the ability of the Guidant VI business units to adapt to the new sterilization modality and functionality and on the overall system reliability. This paper reviews the operating experience to date and the overall system reliability. (author)

  11. Translocation-based genetic sexing system to enhance the sterile insect technique against the melon fly (Diptera: Tephritidae)

    International Nuclear Information System (INIS)

    McCombs, S.D.; Lee, S.G.; Saul, S.H.

    1993-01-01

    The autosomal recessive bubble wing (bw) mutant was used to construct a translocation-based genetic sex sorting system in the melon fly, Bactrocera cucurbitae (Coquillett). The translocation stock has females with the bubble wing phenotype that are unable to fly, but the males are wild-type and fly normally. The bubble wing translocation strain has lower egg hatch, larval viability, and eclosion rates than the wild-type strain. Expression of the bubble wing trait is temperature-dependent, with high expression of the trait in 92% of adults at 23°C but in only 15% of adults at 28°C. This translocation-based sex sorting system is the only method available for automatic separation of male and female melon flies in sterile insect release programs

  12. Pain Associated With Hysteroscopic Sterilization

    Science.gov (United States)

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  13. Food packaging and radiation sterilization

    International Nuclear Information System (INIS)

    Kawamura, Yoko

    1998-01-01

    Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The γ ray and an electron beam are commonly used in radiation sterilization. The γ ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing relatively thin materials and surface sterilization due to the weak transmission. A typical sterilization dose is approximately 10-30 kGy. Direct effects impacting packaging materials, particularly plastics, include scission of polymer links, cross-linkage between polymers, and generating radiolysis products such as hydrogen, methane, aliphatic hydrocarbons, etc. Furthermore, under the existence of oxygen, the oxygen radicals generated by the radiation will oxidize and peroxidize polymer chains and will generate alcohol and carbonyl groups, which shear polymer links, and generate oxygen containing low molecular compounds. As a result, degradation of physical strength such as elongation and seal strength, generating foreign odor, and an increase in global migration values shown in an elution test are sometimes evident. The food packages have different shapes, materials, additives, number of microorganisms and purpose. Therefor the effects of radiation, the optimum dose and so on must be investigated on the individual package. (J.P.N.)

  14. Genomic networks of hybrid sterility.

    Directory of Open Access Journals (Sweden)

    Leslie M Turner

    2014-02-01

    Full Text Available Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities". The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL. Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  15. Genomic networks of hybrid sterility.

    Science.gov (United States)

    Turner, Leslie M; White, Michael A; Tautz, Diethard; Payseur, Bret A

    2014-02-01

    Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities"). The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus) provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL). Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is applicable in a broad

  16. EFFECT OF MICROWAVE POWER ON SHAPE OF EPR SPECTRA--APPLICATION TO EXAMINATION OF COMPLEX FREE RADICAL SYSTEM IN THERMALLY STERILIZED ACIDUM BORICUM.

    Science.gov (United States)

    Ramos, Paweł; Pieprzyca, Małgorzata; Pilawa, Barbara

    2016-01-01

    Complex free radical system in thermally sterilized acidum boricum (AB) was studied. Acidum boricum was sterilized at temperatures and times given by pharmaceutical norms: 160 degrees C and 120 min, 170 degrees C and 60 min and 180 degrees C and 30 min. The advanced spectroscopic tests were performed. The EPR spectra of free radicals were measured as the first derivatives with microwaves of 9.3 GHz frequency and magnetic modulation of 100 kHz. The Polish X-band electron paramagnetic resonance spectrometer of Radiopan (Poznań) was used. EPR lines were not observed for the nonheated AB. The broad EPR asymmetric lines were obtained for all the heated AB samples. The influence of microwave power in the range of 2.2-70 mW on the shape of EPR spectra of the heated drug samples was tested. The following asymmetry parameters: A1/A2, A1-A2, B1/B2, and B1-B2, were analyzed. The changes of these parameters with microwave power were observed. The strong dependence of shape and its parameters on microwave power proved the complex character of free radical system in thermally sterilized AB. Changes of microwave power during the detection of EPR spectra indicated complex character of free radicals in AB sterilized in hot air under all the tested conditions. Thermolysis, interactions between free radicals and interactions of free radicals with oxygen may be responsible for the complex free radicals system in thermally treated AB. Usefulness of continuous microwave saturation of EPR lines and shape analysis to examine free radicals in thermally sterilized drugs was confirmed.

  17. Gamma-sterilization

    International Nuclear Information System (INIS)

    Lindgren, E.

    1974-01-01

    The author makes a survey of his experience in sterilization and sterility control of medical products. At present three different methods are used, steamsterilization, gassterilizing and gammasterilizing. The investments and costs for gamma radiation is presented and a comparison of the costs for gamma- and gassterilization including sterility control is made. (M.S.)

  18. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  19. Cryoradiation sterilization - contemporary state and outlook

    International Nuclear Information System (INIS)

    Talrose, V.L.

    1995-01-01

    The new approach of radiation sterilization -cryoradiosterilization with programmed freezing - was developed for pharmaceutical solutions. Both scientific and technical problems are solved, the results are discussed. Programmed freezing of vials with the drug's solutions provides the high stability of soluted components with biological activity at sterilizing irradiation without significant change of sterilization doses. Physical, chemical, biological and pharmacological properties of a lot of drug solutions for injection satisfy official requirements after cryoradiation sterilization treatment. This method seems to be especially important for the protein systems which could be infected by dangerous viruses (VIH, hepatitis B): blood plasma, diagnostic sera, protein preparations manufactured from donor's blood, etc. (Author)

  20. Morphological and genetic characterization of a new cytoplasmic male sterility system (oxa CMS) in stem mustard (Brassica juncea).

    Science.gov (United States)

    Heng, Shuangping; Liu, Sansan; Xia, Chunxiu; Tang, HongYu; Xie, Fei; Fu, Tingdong; Wan, Zhengjie

    2018-01-01

    KEY MESSAGE: oxa CMS is a new cytoplasmic male sterility type in Brassica juncea. oxa CMS is a cytoplasmic male sterility (CMS) line that has been widely used in the production and cultivation of stem mustard in the southwestern China. In this study, different CMS-type specific mitochondrial markers were used to confirm that oxa CMS is distinct from the pol CMS, ogu CMS, nap CMS, hau CMS, tour CMS, Moricandia arvensis CMS, orf220-type CMS, etc., that have been previously reported in Brassica crops. Pollen grains of the oxa CMS line are sterile with a self-fertility rate of almost 0% and the sterility strain rate and sterility degree of oxa CMS is 100% due to a specific flower structure and flowering habit. Scanning electron microscopy revealed that most pollen grains in mature anthers of the oxa CMS line are empty, flat and deflated. Semi-thin section further showed that the abortive stage of anther development in oxa CMS is initiated at the late uninucleate stage. Abnormally vacuolated microspores caused male sterility in the oxa CMS line. This cytological study combined with marker-assisted selection showed that oxa CMS is a novel CMS type in stem mustard (Brassica juncea). Interestingly, the abortive stage of oxa CMS is later than those in other CMS types reported in Brassica crops, and there is no negative effect on the oxa CMS line growth period. This study demonstrated that this novel oxa CMS has a unique flower structure with sterile pollen grains at the late uninucleate stage. Our results may help to uncover the mechanism of oxa CMS in Brassica juncea.

  1. Use of geographic information systems and spatial analysis in area-wide integrated pest management programmes that integrate the sterile insect technique

    International Nuclear Information System (INIS)

    Cox, J.St.H.; Vreysen, M.J.B.

    2005-01-01

    The advantages that geographic information systems (GIS) and associated technologies can offer, in terms of the design and implementation of area-wide programmes of insect and/or disease suppression, are becoming increasingly recognised, even if the realization of this potential has not been fully exploited and for some area-wide programmes adoption appears to be progressing slowly. This chapter provides a basic introduction to the science of GIS, Global Positioning System (GPS), and satellite remote sensing (RS), and reviews the principal ways in which these technologies can be used to assist various stages of development of the sterile insect technique (SIT) as part of area-wide integrated pest management (AW-IPM) programmes - from the selection of project sites, and feasibility assessments and planning of pre-intervention surveys, to the monitoring and analysis of insect suppression programmes, and the release of sterile insects. Potential barriers to the successful deployment of GIS tools are also discussed. (author)

  2. Ultraviolet sterilization

    International Nuclear Information System (INIS)

    Schenck, G.O.

    1987-01-01

    Artificial ultraviolet radiation sources can supply bactericidal energy in such a high dosage that in less than a second a higher degree of disinfection is accomplished than by sun irradiation in hours. Bacteria, viruses, phages, and organic micropollutants can be degraded by photochemical wet combustion down to and below detection limits of organic carbon. There are no known ultraviolet-resistant microorganisms. There are limitations to ultraviolet treatment which can often be overcome by adequate technical measures. Unlike other water purification processes, ultraviolet irradiation only exterminates living organisms. The radiation must be able to penetrate to the objects of the kill; in a dose large enough to kill, and long enough to kill and prevent new growth. Contrary to filters, ultraviolet flow-through reactors do not restrict free flow significantly. In contrast to distillation, ultraviolet irradiation imposes no phase changes to the water. Used as a sequence in ultrapure water systems, maintenance requirements are virtually nonexistent; because of the absence of dissolved and particulate matter in purified water, mechanical cleaning of the photoreactor chambers is not essential. The process is highly economical; energy consumption is low and supervision minimal. 103 refs., 45 figs., 15 tabs

  3. Irradiation as a means of sterilizing packaging materials for aseptic systems

    International Nuclear Information System (INIS)

    Blundell, M.J.

    1985-01-01

    Long shelf life of foodstuffs is essential in order to feed the nations of the world. For 'wet' products which quickly deteriorate in air, the use of refrigeration, retort processing and preservatives can be considered. For example, the metal can will continue to be a reliable means of keeping meat and vegetable products in good condition for long periods at ambient conditons. Today, people require food items to be free of preservatives and with a flavour and texture very close to the original, at all times of the year, at lowest cost. Minimal heat processing and immediate filling into a pre-sterilised container without any possibility of contact with the atmosphere, is the logical route to take to meet these requirements and constitutes an aseptic system. The filled product remains in prime condition for many months without the need for refrigeration and preservatives. Irradiation is a convenient and cheap means of pre-sterilising plastic bags for Bag-in-Box systems and the writer will describe how fruit juices and fruit purees are now being packaged aseptically in South Africa and overseas

  4. Establishment of a sterilization dose

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    Factors that impact on product bioburden (population of diable microorganisms on or in product and/or sterile barrier system) are: Raw materials, components, product design and size, manufacturing process, manufacturing equipment, manufacturing environment and manufacturing location. Presented lecture describes all these factors in details

  5. Radiosterilization and gas sterilization

    International Nuclear Information System (INIS)

    Schultz, H.A.; Gruenewald, T.

    1987-01-01

    The book presents a survey of the principles of cold sterilization by radiation or gas, and also of the problems involved. The reader who has to do with sterilization of some kind or other, as e.g. sterilization of medicaments, medical supplies, medical device, drugs, grafts, or food, will find comprehensive information on the various available methods and their effects, as well as on monitoring procedures and techniques, together with proposals for efficient documentation and validation of partial sterilization processes. The introduction summarizes the potentials of sterilization by radiation, and the subsequent by radiation, and the subsequent chapters explain the specific applicabilities of radiosterilization along with the most important criteria for evaluating the sterilizing efficiency. The information on the legal situation and requirements takes into account the second amendment of the Medical Preparations Act. With 38 figs., 14 tabs [de

  6. Inherited sterility in insects

    International Nuclear Information System (INIS)

    Carpenter, J.E.; Marec, F.; Bloem, S.

    2005-01-01

    The unique genetic phenomena responsible for inherited sterility (IS) in Lepidoptera and some other arthropods, as compared with full sterility, provide advantages for pest control. Lepidopteran females are usually more sensitive to radiation than males of the same species. This allows the radiation dose to be adjusted to suit programme requirements. When partially sterile males mate with wild females, the radiation-induced deleterious effects are inherited by the F 1 generation. As a result, egg hatch is reduced and the resulting offspring are both highly sterile and predominately male. Compared with the high radiation required to achieve full sterility in Lepidoptera, the lower dose of radiation used to induce F 1 sterility increases the quality and competitiveness of the released insects as measured by improved dispersal after release, increased mating ability, and superior sperm competition. F 1 sterile progeny produced in the field enhance the efficacy of released partially sterile males, and improve compatibility with other pest control strategies. In addition, F 1 sterile progeny can be used to increase the production of natural enemies, and to study the potential host and geographical ranges of exotic lepidopteran pests. (author)

  7. Status of radiation sterilization of healthcare products in China

    International Nuclear Information System (INIS)

    Zhu Nankang; Wang Chunlei; Teng Weifang

    2004-01-01

    This paper describes the status of 60 Co radiation facilities both in service and under construction in China and examines the future market for radiation sterilization of healthcare products. Policies for developing the industry of radiation sterilization are also put forward; these include implementation of appropriate quality systems, scale-up and merging of existing radiation facilities, development of electron beam radiation for sterilization purposes and increasing awareness of the technology of radiation sterilization

  8. Reversibility of female sterilization.

    Science.gov (United States)

    Siegler, A M; Hulka, J; Peretz, A

    1985-04-01

    The discussion considers the current status of reversibility of sterilization in the US and describes clinical and experimental efforts for developing techniques designed for reversibility. It focuses on regret following sterilization, reversal potential of current sterilization techniques, patient selection, current reversal techniques, results of sterilization procedures, experimental approaches to reversal of current techniques of sterilization, and sterilization procedures devised for reversibility, in humans and in animals. Request is the 1st stage of reversal, but a request for sterilization reversal (SR) does not always mean regret for a decision made at the time. Frequently it is a wish to restore fertility because life circumstances have changed after a sterilization that was ppropriate at the time it was performed. Schwyhart and Kutner reviewed 22 studies published between 1949-69 in which they found that the percentage of patients regretting the procedure ranged from 1.3-15%. Requests for reversal remain low in most countries, but if sterilization becomes a more popular method of contraception, requests will also increase. The ideal operation considered as a reversaible method of sterilization should include an easy, reliable outpatient method of tubal occlusion with miniml risk or patient discomfort that subsequently could be reversed without the need for a major surgical intervention. Endoscopic methods have progressed toward the 1st objective. A recent search of the literature uncovered few series of SR of more than 50 cases. The 767 operations found were analyzed with regard to pregnancy outcome. The precent of live births varied from 74-78.8%, and the occurance of tubal pregnancies ranged from 1.7-6.5%. All of the confounding variables in patient selection and small numbers of reported procedures preclude any conclusion about the different techniques or the number of operations that give a surgeon a level of expertise. Few authors classify their

  9. Modular ionizing sterilizer (MIS)

    International Nuclear Information System (INIS)

    Freijo, Jose L.

    1999-01-01

    A transportable device designed to sterilize medical material and wastes by gamma irradiation is described. The sterilizer is formed by three modules: one of the modules contains the gamma source and can be removed to transport and transfer the source, the other modules are designed to introduce and draw out the materials to be irradiated

  10. Radiation sterilization of vitamins - studies on the radiolysis and radiation protection of vitamins in aqueous systems and the solid state

    International Nuclear Information System (INIS)

    Rao, K.N.; Moorthy, P.N.; Kishore, K.

    1978-01-01

    Radiation sterilization of pharmaceutical products may cause their radiation degradation and loss in their potency. Radiation degradation may even give rise to new products whose effects on the organisms could be different from the parent substances. Extent of radiolytic decomposition of vitamins thiamine, nicotinamide, riboflavine and pyridoxine was studied under controlled conditions so that either only the hydrated electrons (esub(aq)) or only hydrogen atom (H) and hydroxyl radical react with these molecules. Experiments were also conducted in which scavengers for these species were added to reduce radiolytic degradation of the vitamins. It was found that irradiation of vitamins in the frozen aqueous state and with addition of glucose reduces radiolytic degradation and their irradiation in dry solid state causes no detectable damage. The last finding indicates that the best method for radiation sterilization of vitamin preparations may be to irradiate the components in the dry solid state and then compound them together. (M.G.B.)

  11. Sterile Neutrinos in Cold Climates

    International Nuclear Information System (INIS)

    Jones, Benjamin J.P.

    2015-01-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin 2 2θ 24 ≤ 0.02 at m 2 ~ 0.3 eV 2 , and the LSND and MiniBooNE allowed regions are excluded at

  12. Thiamine losses during storage of pasteurised and sterilized model systems of minced chicken meat with addition of fresh and oxidized fat, and antioxidants.

    Science.gov (United States)

    Szymandera-Buszka, Krystyna; Hęś, Marzanna; Waszkowiak, Katarzyna; Jędrusek-Golińska, Anna

    2014-01-01

    The aim of the study was to determine the effect of pasteurisation and sterilization of model systems of minced chicken meat in the presence of low or high-oxidised pork lard, soy and sunflower oil, as well as casein hydrolysate and rosemary extract, on losses of thiamine in model systems. In the samples, the thiamine content was analysed periodically by thiochromium method, as well as rate of lipid oxidation based on measurement of peroxide value (PV) by iodometric method and p-anisidine value (AV) by spectrophotometric method. It was observed that the thiamine losses in model systems of minced chicken after pasteurisation (61-71%) were higher than after sterilization (57-67%). Introduction of high-oxidised fat increased the total thiamine losses both during thermal processing and storage of meat samples (to 23%). A strong relationship was established between thiamine losses and rate of fat oxidation. The lowest total thiamine losses were observed in the samples with low-oxidised pork lard. Antioxidant addition (rosemary extract or casein hydrolysate) into meat samples limited the thiamine losses. However, the effect depended on oxidation of fat that was mixed with meat. In the samples with low-oxidised fat, higher protective effect was found for rosemary extract (7-11%). In the samples with high-oxidised fat, casein hydrolysate was superior to rosemary extract (14%). In order to increase the stability of thiamine in pasteurized or sterilized meat products with fats, the influence of fat type and its oxidative stability should be taken under consideration. Moreover, the addition of rosemary extract or casein hydrolysate has impact on the thiamine losses since it slows down lipid oxidation to a significant extent.

  13. [Sterilization and eugenics].

    Science.gov (United States)

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  14. Radiation sterilization facility for melon fly

    International Nuclear Information System (INIS)

    Danno, A.

    1985-01-01

    The melon fly (Dacus cucurbitae Coquillett) has been observed in Amami Island since l975. Kagoshima Prefecture has had a melon fly eradication project underway since 1979. A mass-fearing facility and a radiation sterilization facility were constructed in Naze in March of l98l. In the early stages of the project, sterile insects were produced at the rate of 4 x l0/sup 6/ pupae/week. In the later stages, the activity of the project was enlarged by tenfold. The conditions for design of the radiation sterilization facility, which has been developed with a central control system for automated irradiation, are examined from an engineering standpoint

  15. Radiation sterilization of medical products- current trends and future prospects

    International Nuclear Information System (INIS)

    Sharma, G.

    1997-01-01

    In medical practice use of sterile pharmaceuticals and single use disposable medical devices is steadily increasing. Sterile pharmaceuticals like injections and ophthalmic ointments are required for therapy. Medical devices are employed for diagnostic, drug administration or corrective purposes, and as implants for temporary, short term or long term residence in the human system. All these products are made available in sterile form by treating them to a suitable process of sterilization i.e. dry/wet heat, ethylene oxide (EtO) gas or ionizing radiation. In this paper current trends and future prospects of radiation sterilization of medical products are given in detail. 9 refs., 7 tabs

  16. [Legal statutes on sterilization].

    Science.gov (United States)

    Zupancic, K

    1980-01-01

    Sterilization in Yugoslavia is no population policy measure. Decision about the birth of children is free, a private problem of any individual, a basic right guaranteed by the Constitution. However, according to certain laws in Slovenia and Croatia, sterilization is allowed as a family planning method in persons over 35 year old. Only exceptionally can sterilization be applied in persons younger than 35 years: according to the Slovenian law, in cases when a person lacks the capacity of reasoning and also when there are medical indications, and according to the Croatian law, when there are medical and eugenic reasons (if the child is supposed to be born with negative congenital properties).

  17. Materials Surfaces and sterility

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R.

    2001-04-01

    A question of great interest in sterile and clean room technology is how can we devise a standard for the guarantee of sterility? Sterility is of widespread importance: it gives the life-time of our daily milk or yogurt, dominates the nature of food packing, and determines the feasibility of the miniaturization of biotechnology plants. All these phenomena are based on the principle of bioadhesion. Bioadhesion is also the basis of the biomimetic material technologies, like the attachment of selected protein layers that can be used for nanomasking. (orig.)

  18. Forced sterilization of women as discrimination.

    Science.gov (United States)

    Patel, Priti

    2017-01-01

    There has been a long history of subjecting marginalized women to forced and coerced sterilization. In recent years, the practice has been documented in countries in North and South America, Europe, Asia, and Africa. It has targeted women who are ethnic and racial minorities, women with disabilities, women living with HIV, and poor women. A handful of courts have issued decisions on the recent forced sterilization of marginalized women finding that such actions violate the women's rights. However, they have all failed to address the women's claims of discrimination. The failure to acknowledge that forced sterilization is at its core a violation of the prohibition of discrimination undermines efforts to eradicate the practice. It further fails to recognize that coerced and forced sterilization fundamentally seeks to deny women deemed as "unworthy" the ability to procreate. Four key principles outlined in the human rights in patient care framework highlight the importance of a finding that the prohibition of discrimination was violated in cases of forced sterilization: the need to highlight the vulnerability of marginalized populations to discrimination in health care settings; the importance of the rights of medical providers; the role of the state in addressing systemic human rights violations in health care settings; and the application of human rights to patient care. Based on these principles, it is clear that finding a violation of the prohibition of discrimination in forced sterilization cases is critical in addressing the systemic nature of the practice, acknowledging the marginalization of specific groups and effectively ending forced sterilization through addressing the underlying purpose of the practice. If litigators, non-governmental organizations and judicial officers are mindful of these principles when dealing with cases of forced sterilization, it is likely that they will be better able to eradicate forced sterilization.

  19. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice.

    Science.gov (United States)

    El-Namaky, R; van Oort, P A J

    2017-12-01

    There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two EGMS lines tested here, it was not clear if one or more recessive gene(s) were causing male sterility. This was tested by studying sterility segregation of the F2 populations. Daylength (photoperiod) and minimum temperatures during the period from panicle initiation to flowering had significant effects on male sterility. Results clearly showed that only one recessive gene was involved in causing male sterility. The model was applied to determine the set of sowing dates of two different EGMS lines such that both would flower at the same time the pollen would be completely sterile. In the same time the local popular variety (Sahel 108, the male pollen donor) being sufficiently fertile to produce the hybrid seeds. The model was applied to investigate the viability of the two line breeding system in the same location with climate change (+2oC) and in two other potential locations: in M'Be in Ivory Coast and in the Nile delta in Egypt. Apart from giving new insights in the relation between environment and EGMS, this study shows that these insights can be used to assess safe sowing windows and assess the suitability of sterility and fertility period of different environments for a two line hybrid rice production system.

  20. Dosimetry for electron beam sterilization

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    According to ISO 11137-1 (sect 4.3.4) dosimetry used in the development, validation and routine control of the sterilization process shall have measurement traceability to national or international standards and shall have a known level of uncertainty. It can only be obtained through calibration of the dosimeters. In presented lecture different types of dosimeter systems for electron beams (calorimeters, radiochromic film dosimeters, alanine / EPR) and their calibration are described

  1. Sterilization of space hardware.

    Science.gov (United States)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  2. Sterilization by gamma irradiation

    International Nuclear Information System (INIS)

    Reyes Frias, L.

    1992-01-01

    Since 1980 the National Institute of Nuclear Research counts with an Industrial Gamma Irradiator, for the sterilization of raw materials and finished products. Through several means has been promoted the use of this technology as alternative to conventional methods of sterilization as well as steam treatment and ethylene oxide. As a result of the made promotion this irradiator has come to its saturation limit being the sterilization irradiation one of the main services that National Institute of Nuclear Research offers to producer enterprises of disposable materials of medical use also of raw materials for the elaboration of cosmetic products and pharmaceuticals as well as dehydrated foods. It is presented the trend to the sterilization service by irradiation showed by the compilation data in a survey made by potential customers. (Author)

  3. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  4. Trends in sterilization since the introduction of Essure hysteroscopic sterilization.

    Science.gov (United States)

    Shavell, Valerie I; Abdallah, Mazen E; Shade, George H; Diamond, Michael P; Berman, Jay M

    2009-01-01

    To investigate trends in sterilization in women at the Detroit Medical Center, Michigan (DMC), since the introduction of Essure hysteroscopic sterilization. Retrospective study (Canadian Task Force classification II-2). Outpatient surgery center and university teaching hospitals. Women who underwent interval sterilization procedures at the DMC (Hutzel Women's Hospital, Sinai-Grace Hospital, and the Berry Center) and postpartum sterilization procedures at Hutzel Women's Hospital between January 1, 2002, and December 31, 2007. Permanent sterilization procedures including minilaparotomy tubal ligation, laparoscopic sterilization, Essure hysteroscopic sterilization, and postpartum tubal ligation performed at the time of cesarean section or after vaginal delivery. In all, 5509 permanent sterilization procedures were performed in the 6 years between January 1, 2002, and December 31, 2007, at the DMC facilities analyzed: 2484 interval sterilization procedures at Hutzel Women's Hospital, Sinai-Grace Hospital, and the Berry Center, and 3025 postpartum tubal ligations at Hutzel Women's Hospital. From 2002 through 2007, the decrease in laparoscopic sterilizations from 97.9% to 48.5% of all interval sterilization procedures corresponded significantly with the increase in Essure hysteroscopic sterilizations from 0.0% to 51.3% (p Essure hysteroscopic sterilizations increased significantly from 0.0% to 51.3% of all procedures. Since the approval of Essure hysteroscopic sterilization in November 2002, this minimally invasive method of hysteroscopic sterilization has increased in popularity at the DMC.

  5. Radiation sterilization of medical products

    International Nuclear Information System (INIS)

    Khurshid, S.J.; Hussain, A.M.

    1989-01-01

    Radiation sterilization is the best method of sterilization, essentially for single use medical and surgical products. Pakistan has established a commercial gamma irradiation plant for this purpose. This article overviews the advantages and benefits of radiation sterilization to stimulate the interest of industrialists and the users in this technology. This technology can give a better medical care in the country and the growing demand can only be met by bulk sterilization. The radiation sterilized medical products can also compete well with the products sterilized by other methods in the international market, gamma sterilization is accepted internationally and if adopted it can boost our export of medical products. (author)

  6. Radiation sterilization of livestock feeds

    International Nuclear Information System (INIS)

    Kawashima, Koji

    1984-01-01

    The radiation sterilization of livestock feeds is not much used presently because the process is not known well, and the cost is relatively high. However, its effect of sterilization is absolute, the radiation-sterilized feeds are safe in both nutrition and toxicity, and do not affect the appetite of livestocks, and the radiation energy required is small. In the future, as in the sterilization of medical supplies, feed radiation sterilization plants should be established, to stabilize livestock industry and to contribute to the health control of experimental animals. The following matters are described: radiation, comparison between radiation sterilization and other sterilization methods, the practice of feed radiation sterilization, the adverse effects of radiation sterilization, economic aspect, and the situation of feed radiation sterilization in various countries. (Mori, K.)

  7. Development and optimization of a matrix converter supplying an electronic ballast - UV lamp system for water sterilization

    Science.gov (United States)

    Bokhtache, Aicha Aissa; Zegaoui, Abdallah; Aillerie, Michel; Djahbar, Abdelkader; Hemici, Kheira

    2018-05-01

    Electronic ballasts dedicated to discharge lamps allow improving the quality of radiation by operating at high frequency. In the present work, the use of a single-phase direct converter with a matrix structure for supplying a low-pressure mercury-argon UVC lamp for water sterilization is proposed. The structure of the converter is based on two switching cells allowing the realization of a fully controllable bidirectional switches. The advantages of such a matrix topology include the delivered of a sinusoidal waveform current with a controllable power factor close to unity, variable in amplitude and frequency. In order to obtain the desired amplitude and frequency, a PWM control was associated in the current realization. Finally, a linear adjustment of the lamp arc current was warranted by using of a PI regulator.

  8. Consultants Group Meeting on Production System Analysis and Economics for Tsetse Fly Mass-Rearing and the Use of the Sterile Insect Technique in Eradication Programmes in Africa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-07-01

    A consultants' group met in Vienna from 23 September - 3 October 1991 to explore 'Production System Analysis and Economics for Tsetse Fly Mass-rearing and the Use of the Sterile Insect Technique in Eradication Programmes in Africa'. This report is based on their observations during working visits to the Entomology Unit of the IAEA Agricultural Laboratory at Seibersdorf, and on information supplied by the tsetse team and staff of the Joint FAO/IAEA Division's Insect and Pest Control Section. The consultants conducted a technical, operational and financial review of present rearing methods, equipment, philosophies and production capacities, taking into account one of the recommendations made at the 6th Session of the ''FAO Commission on African Animal Trypanosomiasis'' held in June 1991 in Harare, Zimbabwe. This recommendation, related to the use of the Sterile Insect Technique (SIT), states that {sup F}AO, through the Joint FAO/IAEA Division, should further investigate and improve the use of sterile insects to strengthen the efficacy of tsetse surveys and, where applicable, consider teh use of the SIT to support eradication campaigns where other techniques on their own will not achieve this objective''. In investigating the potential for improved tsetse mass-rearing and analyzing the present costs of pupa/distributable sterile fly production, the consultants noted that: 1. The Seibersdorf Tsetse Unit is conducting an effective research and development programme which strives to emulate a production facility while continuing to pursue R and D. The capacity of the present facility in Seibersdorf is practically limited to a colony size of about 150,000 breeding females. The release of sterile males in an eradication campaign of economical relevance would require a colony containing more than 500,000 female flies. Such a population can only be maintained in an organizational, operational and financially justifiable manner if the rearing technology is transferred from an

  9. Sterile Neutrinos in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Benjamin J.P. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  10. Audits of radiation sterilization facilities

    International Nuclear Information System (INIS)

    Kelkar, Prabhakar M.

    2001-01-01

    Johnson and Johnson is the world leader in sterilization science and technology. A special group of scientists and technologists are engaged in the development of new methods of sterilization, worldwide monitoring of sterilization processes, equipment and approvals for all types of sterilization processes. Kilmer Conference in the alternate year for the benefit of all those involved in improvement in sterilization science is held. Cobalt-60 gamma radiation for sterilization of medical products on commercial scale is used. This kind of mammoth task can only be achieved through systematic method of planning, auditing, expert review and approval of facilities

  11. Sterility induction in tsetse

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, C F [London School of Hygiene and Tropical Medicine (UK); Langley, P A [Bristol Univ. (UK)

    1982-01-01

    The first laboratory and field experiments on genetic control were with tsetse flies, and they made use of the sterility in crosses and hybrids between closely related species of the Glossina morsitans complex. Backcrosses indicate that there are two separate sterility mechanisms involved: (a) genetic incompatibility between a mother and the products of alien genes in the embryo or larva in the uterus; (b) inability of hybrid males to inseminate due to incompatibility of their X-chromosomes with an alien Y or autosomes. The two largest sterile male release programmes have been in Tanzania and Upper Volta, and have used irradiation at the pupal or adult stage, respectively, for the production of sterility. Male tsetse are remarkably resistant to radiosterilization and, with the doses required to induce dominant lethals in more than 95% of sperms, premature senescence and lethargic behaviour of the males tends to result. With G. morsitans irradiated at the puparial stage these effects can be alleviated by the use of a nitrogen atmosphere during irradiation. If the puparia are then transferred to air at 11/sup 0/C for transport to the release site, immediate emergence occurs on re-warming after arrival. This advantageous procedure was used for the releases in Tanzania. In addition to dominant lethals, irradiation also produces chromosome translocations which cause inherited partial sterility. A homozygous translocation line was selected but this example did not have sufficient fitness to be used in a mass rearing programme. Chemosterilants can be applied by pupal dipping, adult contact with deposits or in aerosols. Studies are now in progress on their use in association with odour-baited traps or pheromone-baited decoys as a means of sterilizing the wild population and thus avoiding the costly and difficult process of mass rearing tsetse.

  12. Male sterility in plants. Induction, isolation and utilization

    International Nuclear Information System (INIS)

    Driscoll, C.J.; Barlow, K.K.

    1976-01-01

    Both induced and spontaneously arising male sterility mutants exist in a number of important plant species. These mutants are somewhat unique in that they effect procedures for breeding improved varieties. They allow for the possibility of easily obtaining large numbers of hybrids, population breeding systems and the production of hybrid varieties. These mutants are normally classified as cytoplasmic mutants or chromosomal mutants, the latter also being referred to as nuclear or genic mutants. Specific examples of these types of sterility are examined in relation to the breeding system of the species and their potential use for varietal development. Male sterility in diploid and polyploid species is compared, with reference to gene duplication in polyploids. The mechanism of male sterility is examined in the various species at the anatomical and biochemical levels. Methods of isolating male sterility mutants are compared and a specific example is outlined for hexaploid wheat. Future use of male sterility mutants for improving varieties of various crops is examined. (author)

  13. End-preparation assessments and tests for compounded sterile preparations.

    Science.gov (United States)

    McElhiney, Linda F

    2013-01-01

    Outsourcing has become a necessity to obtain sterile products that are currently on backorder. Because of the expense of outsourcing sterile compounding, pharmacy leadership in health systems are now considering the option of insourcing and batch preparing compounded sterile preparations, which can be a viable option for a health system. It can significantly decrease drug-spending costs, and the pharmacy has a complete record of the compounding process. The key to preparing high-quality, safe, sterile preparations and meeting United States Pharmacopeia standards is end-preparation assessments and tests.

  14. Lipidomics: The Function of Vital Lipids in Embryogenesis Preventing Autism Spectrum Disorders, Treating Sterile Inflammatory Diatheses with a Lymphopoietic Central Nervous System Component

    Directory of Open Access Journals (Sweden)

    Thomas Tallberg

    2011-01-01

    Full Text Available The central role performed by billions of vital central nervous system (CNS lipids “lipidomics” in medical physiology is usually overlooked. A metabolic deficiency embracing these vital lipids can form the aetiology for a variety of diseases. CNS lipids regulate embryogenesis, cell induction, mental balance by preventing autism spectrum disorders, depression, burn-out syndromes like posttraumatic stress disease PTSD, by guarding normal immunity, treating sterile inflammatory diatheses with a titanium containing lymphopoietic CNS lipid component. The propaganda driving for unphysiological fat-free diets is dangerous and can cause serious health problems for a whole generation. This article presents a broad list of various mental and motor bodily functions of which the healthy function depends on these vital CNS lipids. A rigorous fat-free diet can provoke these metabolic lipid deficiencies but they can fortunately be compensated by dietary supplementation, but not by pharmacologic treatment.

  15. Lipidomics: the function of vital lipids in embryogenesis preventing autism spectrum disorders, treating sterile inflammatory diatheses with a lymphopoietic central nervous system component.

    Science.gov (United States)

    Tallberg, Thomas; Dabek, Jan; Hallamaa, Raija; Atroshi, Faik

    2011-01-01

    The central role performed by billions of vital central nervous system (CNS) lipids "lipidomics" in medical physiology is usually overlooked. A metabolic deficiency embracing these vital lipids can form the aetiology for a variety of diseases. CNS lipids regulate embryogenesis, cell induction, mental balance by preventing autism spectrum disorders, depression, burn-out syndromes like posttraumatic stress disease PTSD, by guarding normal immunity, treating sterile inflammatory diatheses with a titanium containing lymphopoietic CNS lipid component. The propaganda driving for unphysiological fat-free diets is dangerous and can cause serious health problems for a whole generation. This article presents a broad list of various mental and motor bodily functions of which the healthy function depends on these vital CNS lipids. A rigorous fat-free diet can provoke these metabolic lipid deficiencies but they can fortunately be compensated by dietary supplementation, but not by pharmacologic treatment.

  16. Heat sterilization of wood

    Science.gov (United States)

    Xiping Wang

    2010-01-01

    Two important questions should be considered in heat sterilizing solid wood materials: First, what temperature–time regime is required to kill a particular pest? Second, how much time is required to heat the center of any wood configuration to the kill temperature? The entomology research on the first question has facilitated the development of international standards...

  17. MINOS Sterile Neutrino Search

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, David Jason [Univ. College London, Bloomsbury (United Kingdom)

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  18. Sterile insect supply, emergence, and release

    International Nuclear Information System (INIS)

    Dowell, R.V.; Worley, J.; Gomes, P.J.

    2005-01-01

    Insect mass-rearing for a sterile insect technique (SIT) programme is designed to move beyond the large-scale rearing of insects in a laboratory to the industrial production of consistently high-quality insects for sterilization and release. Each facility reflects the unique biology of the insect reared within it, but there are some generalities for all rearing facilities. Rearing insects in self-contained modules offers flexibility, and increased safety from catastrophic occurrences, compared with using a single building which houses all facets of the rearing process. Although mechanizing certain aspects of the rearing steps helps provide a consistently high-quality insect, successful mass-rearing and delivery depends largely upon the human component. Besides production in centralized facilities, insects can be produced from purchased eggs, or nowadays, adult insects are often obtained from specialized satellite emergence/collection facilities. Interest in commercializing insect production and release is increasing. Shipping sterile insects, sometimes over long distances, is now common practice. Procedures for handling and chilling adult insects, and providing food and water prior to release, are continually being improved. Sterile insects are released via static-release receptacles, ground-release systems, or most commonly from the air. The aerial release of chilled sterile insects is the most efficient method of release, especially when aircraft flight paths are guided by a Global Positioning System (GPS) linked to a computer-controlled release mechanism. (author)

  19. Exploiting novel sterilization techniques for porous polyurethane scaffolds.

    Science.gov (United States)

    Bertoldi, Serena; Farè, Silvia; Haugen, Håvard Jostein; Tanzi, Maria Cristina

    2015-05-01

    Porous polyurethane (PU) structures raise increasing interest as scaffolds in tissue engineering applications. Understanding the effects of sterilization on their properties is mandatory to assess their potential use in the clinical practice. The aim of this work is the evaluation of the effects of two innovative sterilization techniques (i.e. plasma, Sterrad(®) system, and ozone) on the morphological, chemico-physical and mechanical properties of a PU foam synthesized by gas foaming, using water as expanding agent. In addition, possible toxic effects of the sterilization were evaluated by in vitro cytotoxicity tests. Plasma sterilization did not affect the morphological and mechanical properties of the PU foam, but caused at some extent degradative phenomena, as detected by infrared spectroscopy. Ozone sterilization had a major effect on foam morphology, causing the formation of new small pores, and stronger degradation and oxidation on the structure of the material. These modifications affected the mechanical properties of the sterilized PU foam too. Even though, no cytotoxic effects were observed after both plasma and ozone sterilization, as confirmed by the good values of cell viability assessed by Alamar Blue assay. The results here obtained can help in understanding the effects of sterilization procedures on porous polymeric scaffolds, and how the scaffold morphology, in particular porosity, can influence the effects of sterilization, and viceversa.

  20. Gene, protein and network of male sterility in rice

    Directory of Open Access Journals (Sweden)

    Wang eKun

    2013-04-01

    Full Text Available Rice is one of the most important model crop plants whose heterosis has been well exploited in commercial hybrid seed production via a variety of types of male sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and proteins related to cytoplasmic male sterility, photoperiod sensitive male sterility, self-incompatibility and other types of microspores deterioration have been characterized through genetics or proteomics. Especially the latter, offers us a powerful and high throughput approach to discern the novel proteins involving in male-sterile pathways which may help us to breed artificial male-sterile system. This represents an alternative tool to meet the critical challenge of further development of hybrid rice. In this paper, we reviewed the recent developments in our understanding of male sterility in rice hybrid production across gene, protein and integrated network levels, and also, present a perspective on the engineering of male sterile lines for hybrid rice production.

  1. Genetically conditioned male sterility

    International Nuclear Information System (INIS)

    Gottschalk, W.

    1976-01-01

    A survey is given of two different types of genetically controlled male sterility in higher plants. 'Functional' male sterility is due to the action of mutated genes causing a misdifferentiation of the growing points in different specific ways. Under the influence of the genes of this group either the stamens or the archespore tissues are not differentiated. In other mutants functionable male germ cells are produced but cannot be used for fertilizing the egg cells because the anthers remain closed or anthers and stigma become spatially separated from each other. Other genes of the group are responsible for the transformation of stamens into carpels, i.e. for a change of the hermaphrodite flower into a unisexually female one. A second type of male sterility is due to the action of ms genes influencing the course of micro-sporogenesis directly. They cause the breakdown of this process in a specific meiotic stage characteristic for each gene of the group. This breakdown is introduced by the degeneration of PMCs, microspores, or pollen grains preventing the production of male germ cells. The female sex organs remain uninfluenced. (author)

  2. Sterilization by oxygen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Adir Jose; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Silva Zambon, Luis da; Silva, Monica Valero da; Verdonck, Patrick Bernard

    2004-07-31

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  3. Color stability of shade guides after autoclave sterilization.

    Science.gov (United States)

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  4. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards...... and documented uncertainty limits of the dose measurements can be used to specify process control limits. This is also useful, for example, when dose setting experiments are carried out according to the methods described in ISO 11137, where product samples shall be irradiated within narrow limits......., the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  5. Laying-up of sterile instruments in the operating theatre: equal or superior protection by using a horizontal unidirectional air flow system.

    Science.gov (United States)

    Traversari, A A L; Goedhart, C A; Dusseldorp, E; Bode, A; Keuning, F; Pelk, M S J; Vos, M C

    2013-10-01

    A system for the preparation of sterilized instruments with unidirectional horizontal air flow (UDHF) has several advantages over a unidirectional down flow system (UDDF). The advantages are based on the installation of the system being more flexible and easier to use, no cooling of the air flow being necessary and less air being needed for circulation, resulting in reduced energy use. The objective of this study was to determine whether a system with UDHF performs equal or superior to a system with UDDF in terms of prevention of contamination of the air (the presence of particles and micro-organisms) during the laying-up process. The degree of protection (DP) offered by two UDHF system variants and two UDDF system variants was determined for several static set-ups and a dynamic simulation of the process. In addition to determining the level of protection for several categories of particle size, colony-forming units (CFU) were also measured during process simulations. When maximum protection (no particles present) is considered, the UDHF systems performed significantly better than the UDDF systems for particles ≥2.5μm. When particles were present, there was no significant difference between systems for particles ≥0.3 and ≥0.5μm. However, the performance of the UDHF system was superior to that of the UDDF system (DP) for particles ≥1.0μm representing the bacteria-carrying particles. During the process measurements, no CFU were found with the UDDF system in 64% of the measurements, compared with 90% for the UDHF system (P = 0.012). The UDHF system offers equal or superior protection to the UDDF system against contamination of the clean area within which the laying up takes place. Despite our finding that the differences did not always reach statistical significance (due to low background concentrations), there is a clear trend, from the small-sized particles (≥1.0μm) up to the largest sizes considered, including bacteria-carrying particles, that

  6. Cost-effectiveness analysis comparing the essure tubal sterilization procedure and laparoscopic tubal sterilization.

    Science.gov (United States)

    Thiel, John A; Carson, George D

    2008-07-01

    To analyze the financial implications of establishing a hysteroscopic sterilization program using the Essure micro-insert tubal sterilization system in an ambulatory clinic. A retrospective cohort study (Canadian Task Force classification Type II-2), in an ambulatory women's health clinic in a tertiary hospital, of 108 women undergoing Essure coil insertion between 2005 and 2006, and 104 women undergoing laparoscopic tubal sterilization for permanent sterilization between 2001 and 2004. The Essure procedures used a 4 mm single channel operative hysteroscope and conscious sedation (fentanyl and midazolam); the laparoscopic tubal sterilizations were completed under general anaesthesia with a 7 mm laparoscope and either bipolar cautery or Filshie clips. Costs associated with the procedure, follow-up, and management of any complications (including nursing, hospital charges, equipment, and disposables) were tabulated. The Essure coils were successfully placed on the first attempt in 103 of 108 women (95%). Three patients required a second attempt to complete placement and two patients required laparoscopic tubal sterilization after an unsuccessful Essure. All 104 laparoscopic tubals were completed on the first attempt with no complications reported. The total cost for the 108 Essure procedures, including follow-up evaluation, was $138,996 or $1287 per case. The total cost associated with the 104 laparoscopic tubal sterilization procedures was $148,227 or $1398 per case. The incremental cost-effectiveness ratio was $111. The Essure procedure in an ambulatory setting resulted in a statistically significant cost saving of $111 per sterilization procedure. Carrying out the Essure procedure in an ambulatory setting frees space in the operating room for other types of cases, improving access to care for more patients.

  7. Development of female fruit fly, Ceratitis species, attractant systems for trapping and sterility assessment in South Africa

    International Nuclear Information System (INIS)

    Eyles, D.K.; Du Plessis, N.; Barnes, B.N.

    1999-01-01

    Fruit in the Western Cape Province of South Africa is attacked by the Mediterranean fruit fly, Ceratitis capitata, and the Natal fruit fly, C. rosa. Control costs and crop losses amount to an estimated US$ 5 million per year. The ARC-Fruit, Vine and Wine Research Institute in Stellenbosch has been taking part in the FAO/IAEA Co-ordinated Research Programme (CRP) to develop a female attractant systems for C. capitata during the 1996/97 and 1997/98 growing seasons. These seasons represented Year 3 and Year 4, respectively, of the female attractant CRP. The performance of these attractant systems in monitoring C. rosa was also evaluated. The Year 3 trial was carried out in a plum orchard with a low fruit fly population, and the Year 4 trial was carried out in the same plum orchard, as well as in a pear orchard with a high fruit fly population. Four female trapping systems were evaluated in Year 3 and five in Year 4. In Year 3, two systems consisted of a locally-manufactured buckettype 'Sensus' trap containing one of two different female attractants (β-caryophyllene, or β-caryophyllene + protein hydrolysate), one was a McPhail trap (IPMT) baited with borax + protein hydrolysate, and the fourth was an open bottom dry trap (OBDT) baited with the three component ammonium acetate, putrescine and trimethylamine system (FA-3). Sensus traps and Jackson traps baited with the male fruit fly attractant Trimedlure (TML) were also included. In Year 4, there was one wet and one dry IPMT system (both baited with FA-3), one IPMT system (borax + protein hydrolysate), and one wet and one dry Tephri trap system (both with FA-3). Jackson traps baited with TML were also included. Results from Year 3 showed that of the systems tested, the best female C. capitata attractant systems under low population conditions were the IPMT system baited with borax + protein hydrolysate, and the OBDT system baited with FA-3. β-caryophyllene in a Sensus trap did not adequately attract female C

  8. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Science.gov (United States)

    Galante, Raquel; Rediguieri, Carolina F; Kikuchi, Irene Satiko; Vasquez, Pablo A S; Colaço, Rogério; Serro, Ana Paula; Pinto, Terezinha J A

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  9. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Raquel Galante

    Full Text Available In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation, a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP hydrogel nanoparticles (CS-HNP, with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol. Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  10. Sterilizing insects with ionizing radiation

    International Nuclear Information System (INIS)

    Bakri, A.; Mehta, K.; Lance, D.R.

    2005-01-01

    Exposure to ionizing radiation is currently the method of choice for rendering insects reproductively sterile for area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Gamma radiation from isotopic sources (cobalt-60 or caesium-137) is most often used, but high-energy electrons and X-rays are other practical options. Insect irradiation is safe and reliable when established safety and quality-assurance guidelines are followed. The key processing parameter is absorbed dose, which must be tightly controlled to ensure that treated insects are sufficiently sterile in their reproductive cells and yet able to compete for mates with wild insects. To that end, accurate dosimetry (measurement of absorbed dose) is critical. Irradiation data generated since the 1950s, covering over 300 arthropod species, indicate that the dose needed for sterilization of arthropods varies from less than 5 Gy for blaberid cockroaches to 300 Gy or more for some arctiid and pyralid moths. Factors such as oxygen level, and insect age and stage during irradiation, and many others, influence both the absorbed dose required for sterilization and the viability of irradiated insects. Consideration of these factors in the design of irradiation protocols can help to find a balance between the sterility and competitiveness of insects produced for programmes that release sterile insects. Many programmes apply 'precautionary' radiation doses to increase the security margin of sterilization, but this overdosing often lowers competitiveness to the point where the overall induced sterility in the wild population is reduced significantly. (author)

  11. Laparoscopic female sterilization.

    Science.gov (United States)

    Filshie, G M

    1989-09-01

    An overview of laparoscopic sterilization techniques from a historical and practical viewpoint includes instrumentation, operative techniques, mechanical occlusive devices, anesthesia, failure rates, morbidity and mortality. Laparoscope was first reported in 1893, but was developed simultaneously in France, Great Britain, Canada and the US in the 1960s. There are smaller laparoscopes for double-puncture procedures, and larger, single-puncture laparoscopes. To use a ring or clip, a much larger operating channel, up to 8 mm is needed. Insufflating gas may be CO2, which does not support combustion, but is more uncomfortable, NO2, which is also an anesthetic, and room air often used in developing countries. Unipolar electrocautery is now rarely used, in fact most third party payers do not allow it. Bipolar cautery, thermal coagulation and laser photocoagulation are safer methods. Falope rings, Hulka-Clemens, Filshie, Bleier, Weck and Tupla clips are described and illustrated. General anesthesia, usually a short acting agent with a muscle relaxant, causes 33% of the mortality of laparoscope, often due to cardiac arrest and arrhythmias, preventable with atropine. Local anesthesia is safer and cheaper and often used in developing countries. Failure rates of the various laparoscopic tubal sterilization methods are reviewed: most result from fistula formation. Mortality and morbidity can be caused by bowel damage, injury or infection, pre- existing pelvic infection, hemorrhage, gas embolism (avoidable by the saline drip test), and other rare events.

  12. A simple genetic incompatibility causes hybrid male sterility in mimulus.

    Science.gov (United States)

    Sweigart, Andrea L; Fishman, Lila; Willis, John H

    2006-04-01

    Much evidence has shown that postzygotic reproductive isolation (hybrid inviability or sterility) evolves by the accumulation of interlocus incompatibilities between diverging populations. Although in theory only a single pair of incompatible loci is needed to isolate species, empirical work in Drosophila has revealed that hybrid fertility problems often are highly polygenic and complex. In this article we investigate the genetic basis of hybrid sterility between two closely related species of monkeyflower, Mimulus guttatus and M. nasutus. In striking contrast to Drosophila systems, we demonstrate that nearly complete hybrid male sterility in Mimulus results from a simple genetic incompatibility between a single pair of heterospecific loci. We have genetically mapped this sterility effect: the M. guttatus allele at the hybrid male sterility 1 (hms1) locus acts dominantly in combination with recessive M. nasutus alleles at the hybrid male sterility 2 (hms2) locus to cause nearly complete hybrid male sterility. In a preliminary screen to find additional small-effect male sterility factors, we identified one additional locus that also contributes to some of the variation in hybrid male fertility. Interestingly, hms1 and hms2 also cause a significant reduction in hybrid female fertility, suggesting that sex-specific hybrid defects might share a common genetic basis. This possibility is supported by our discovery that recombination is reduced dramatically in a cross involving a parent with the hms1-hms2 incompatibility.

  13. Validation of shortened 2-day sterility testing of mesenchymal stem cell-based therapeutic preparation on an automated culture system.

    Science.gov (United States)

    Lysák, Daniel; Holubová, Monika; Bergerová, Tamara; Vávrová, Monika; Cangemi, Giuseppina Cristina; Ciccocioppo, Rachele; Kruzliak, Peter; Jindra, Pavel

    2016-03-01

    Cell therapy products represent a new trend of treatment in the field of immunotherapy and regenerative medicine. Their biological nature and multistep preparation procedure require the application of complex release criteria and quality control. Microbial contamination of cell therapy products is a potential source of morbidity in recipients. The automated blood culture systems are widely used for the detection of microorganisms in cell therapy products. However the standard 2-week cultivation period is too long for some cell-based treatments and alternative methods have to be devised. We tried to verify whether a shortened cultivation of the supernatant from the mesenchymal stem cell (MSC) culture obtained 2 days before the cell harvest could sufficiently detect microbial growth and allow the release of MSC for clinical application. We compared the standard Ph. Eur. cultivation method and the automated blood culture system BACTEC (Becton Dickinson). The time to detection (TTD) and the detection limit were analyzed for three bacterial and two fungal strains. The Staphylococcus aureus and Pseudomonas aeruginosa were recognized within 24 h with both methods (detection limit ~10 CFU). The time required for the detection of Bacillus subtilis was shorter with the automated method (TTD 10.3 vs. 60 h for 10-100 CFU). The BACTEC system reached significantly shorter times to the detection of Candida albicans and Aspergillus brasiliensis growth compared to the classical method (15.5 vs. 48 and 31.5 vs. 48 h, respectively; 10-100 CFU). The positivity was demonstrated within 48 h in all bottles, regardless of the size of the inoculum. This study validated the automated cultivation system as a method able to detect all tested microorganisms within a 48-h period with a detection limit of ~10 CFU. Only in case of B. subtilis, the lowest inoculum (~10 CFU) was not recognized. The 2-day cultivation technique is then capable of confirming the microbiological safety of MSC and

  14. Electrolytic silver ion cell sterilizes water supply

    Science.gov (United States)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  15. Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2007-01-01

    This part of ISO 11135 describes requirements that, if met, will provide an ethylene oxide sterilization process intended to sterilize medical devices, which has appropriate microbicidal activity. Furthermore, compliance with the requirements ensures that this activity is both reliable and reproducible so that it can be predicted, with reasonable confidence, that there is a low level of probability of there being a viable microorganism present on product after sterilization. Specification of this probability is a matter for regulatory authorities and may vary from country to country. The paper provides information on scope, normative references, terms and definitions, quality management systems, sterilizing agent characterization, process and equipment characterization, product definition, process definition, validation, routine monitoring and control, product release from sterilization and maintaining process effectiveness followed by Annex A (Determination of lethal rate of the sterilization process - Biological indicator/bioburden approach), Annex B (Conservative determination of lethal rate of the sterilization process - Overkill approach, annex C (General guidance) and a bibliography.

  16. Thermalizing Sterile Neutrino Dark Matter.

    Science.gov (United States)

    Hansen, Rasmus S L; Vogl, Stefan

    2017-12-22

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  17. Thermalizing Sterile Neutrino Dark Matter

    Science.gov (United States)

    Hansen, Rasmus S. L.; Vogl, Stefan

    2017-12-01

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  18. Sterile Endophthalmitis after Intravitreal Injections

    Directory of Open Access Journals (Sweden)

    Joaquín Marticorena

    2012-01-01

    Full Text Available Sterile endophthalmitis appears as an infrequent complication of intravitreal injections and seems to develop mainly in the context of the off-label use of drugs that have not been conceived for intravitreous administration. The aetiology of sterile endophthalmitis, independently of the administered drug, remains uncertain and a multifactorial origin cannot be discarded. Sterile inflammation secondary both to intravitreal triamcinolone acetonide and to intravitreal bevacizumab share many characteristics such as the acute and painless vision loss present in the big majority of the cases. Dense vitreous opacity is a common factor, while anterior segment inflammation appears to be mild to moderate. In eyes with sterile endophthalmitis, visual acuity improves progressively as the intraocular inflammation reduces without any specific treatment. If by any chance the ophthalmologist is not convinced by the sterile origin of the inflammation, this complication must be treated as an acute endophthalmitis because of the devastating visual prognosis of this intraocular infection in the absence of therapy.

  19. Validation of the sterile manufacture of the AAEC MARK III molybdenum-99/techtnetium-99m generator

    International Nuclear Information System (INIS)

    Saunders, M.T.; Drummond, C.M.; Harrison, M.A.

    1982-07-01

    The Mark II molybdenum-99/technetium-99m generator now supplied to hospitals by the Australian Atomic Energy Commission is a non-sterile elution system. The Mark III version will be supplied as a sterile elution system. A validation study has been undertaken to assess the capability of the new production facility, to evaluate up-to-date procedures for manufacturing sterile generators and to demonstrate that a sterile radionuclide generator can be made. Generator manufacturing procedures and a time study of the validation are described. Microbiological methods for monitoring in-process aspects of manufacture, disinfectant efficacy and generator sterility are defined

  20. Biological basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Lance, D.R.; McInnis, D.O.

    2005-01-01

    In principle, the sterile insect technique (SIT) is applicable to controlling a wide variety of insect pests, but biological factors, interacting with socio-economic and political forces, restrict its practical use to a narrower set of pest species and situations. This chapter reviews how the biology and ecology of a given pest affect the feasibility and logistics of developing and using the SIT against that pest insect. The subjects of pest abundance, distribution, and population dynamics are discussed in relation to producing and delivering sufficient sterile insects to control target populations. Pest movement and distribution are considered as factors that influence the feasibility and design of SIT projects, including the need for population- or area-wide management approaches. Biological characteristics, that affect the ability of sterile insects to interact with wild populations, are presented, including the nature of mating systems of pests, behavioural and physiological consequences of mass production and sterilization, and mechanisms that males use to block a female's acquisition and/or use of sperm from other males. An adequate knowledge of the biology of the pest species and potential target populations is needed, both for making sound decisions on whether integration of the SIT into an area-wide integrated pest management (AW-IPM) programme is appropriate, and for the efficient and effective application of the technique. (author)

  1. Conditional sterility in plants

    Science.gov (United States)

    Meagher, Richard B.; McKinney, Elizabeth; Kim, Tehryung

    2010-02-23

    The present disclosure provides methods, recombinant DNA molecules, recombinant host cells containing the DNA molecules, and transgenic plant cells, plant tissue and plants which contain and express at least one antisense or interference RNA specific for a thiamine biosynthetic coding sequence or a thiamine binding protein or a thiamine-degrading protein, wherein the RNA or thiamine binding protein is expressed under the regulatory control of a transcription regulatory sequence which directs expression in male and/or female reproductive tissue. These transgenic plants are conditionally sterile; i.e., they are fertile only in the presence of exogenous thiamine. Such plants are especially appropriate for use in the seed industry or in the environment, for example, for use in revegetation of contaminated soils or phytoremediation, especially when those transgenic plants also contain and express one or more chimeric genes which confer resistance to contaminants.

  2. The Sterile Insect Technique

    International Nuclear Information System (INIS)

    Kiragu, J.

    2006-01-01

    Insect pests have caused an increasing problem in agriculture and human health through crop losses and disease transmission to man and livestock. Intervention to ensure food security and human health has relied on Integrated Pest Management (IPM) strategies to keep the pests population below economic injury levels. IPM integrate a variety of methods, but there has been over-reliance on chemical control following the discovery of insecticidal properties of DDT. It is now realized that, maintaining pest populations at controlled levels is unsustainable and eradication options is now being considered. Although the Sterile Insect Technique(SIT) could be used for insect suppression, it is gaining favour in the elimination (eradication) of the target pest population through Areawide-based IPM (Author)

  3. Sterile neutrino dark matter

    CERN Document Server

    Merle, Alexander

    2017-01-01

    This book is a new look at one of the hottest topics in contemporary science, Dark Matter. It is the pioneering text dedicated to sterile neutrinos as candidate particles for Dark Matter, challenging some of the standard assumptions which may be true for some Dark Matter candidates but not for all. So, this can be seen either as an introduction to a specialized topic or an out-of-the-box introduction to the field of Dark Matter in general. No matter if you are a theoretical particle physicist, an observational astronomer, or a ground based experimentalist, no matter if you are a grad student or an active researcher, you can benefit from this text, for a simple reason: a non-standard candidate for Dark Matter can teach you a lot about what we truly know about our standard picture of how the Universe works.

  4. Device and Container for Reheating and Sterilization

    Science.gov (United States)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  5. Sterile neutrinos as dark matter

    International Nuclear Information System (INIS)

    Dodelson, S.; Widrow, L.M.

    1994-01-01

    The simplest model that can accommodate a viable nonbaryonic dark matter candidate is the standard electroweak theory with the addition of right-handed (sterile) neutrinos. We consider a single generation of neutrinos with a Dirac mass μ and a Majorana mass M for the right-handed component. If M much-gt μ (standard hot dark matter corresponds to M=0), then sterile neutrinos are produced via oscillations in the early Universe with energy density independent of M. However, M is crucial in determining the large scale structure of the Universe; for M∼100 eV, sterile neutrinos make an excellent warm dark matter candidate

  6. Radio-sterilization and processing of frozen human skin

    International Nuclear Information System (INIS)

    Zarate S, Herman; Aguirre H, Paulina; Silva R, Samy; Hitschfeld G, Mario

    2006-01-01

    The Laboratory of Radio-sterilized Biological Tissues Processing (LPTR) belonging to the Chilean Commission of Nuclear Energy and the International Atomic Energy Agency have played a paramount role in our country, concerning the biological tissue processing, which can be radio-sterilized as human skin, pig skin, amniotic membrane, human bone and bovine bone. The frozen radio.-sterilized human skin processing began in 2001, by means of putting into practice the knowledge acquired in training courses through the IAEA and the experience transferred by experts who visited our laboratory. The human skin processing of dead donor can be divided into 6 stages: a) Profuse washing with physiological sterilized serum in to remove the microorganisms, chemical and pharmacological compounds; b) immersion in glycerol solution at 10% to better keep the stored tissues; c) packing, to avoid post manipulation of the sterilized tissue; d) microbiological controls which allow and guarantee a sterility assurance level of 10 6 ; e) radio-sterilization, technique that consists of exposing the grafts to electromagnetic gamma waves which eliminate the microorganisms of the tissue, f) and finally, dispatching and liberation of the frozen sterilized human skin for its clinical use in different centers that take care of burned people. The LPTR receives feedback from surgeons who have used these tissues in order to improve the processing stages based in an integral quality system ISO 9001.2000. The State Health System in our country counts on limited and scarce resources to implement synthetic substitutes that is why It is considered necessary to spread the use of these noble tissues which have sterility assurance and they are processed at low price

  7. Male gametophytic sterility. 1 - Gametic sterilities and deletions in petunia

    Energy Technology Data Exchange (ETDEWEB)

    Cornu, A.; Maizonnier, D. (Station d' Amelioration des Plantes de l' I.N.R.A., Dijon (France))

    1982-01-01

    Terminal deletions induced by ionizing radiations in Petunia are not sexually transmitted. Cytogenetic study of plants with a heterozygous deletion and their progenies shows that this lack of transmission is accompanied by a gametic semi-sterility due to the fact that gametes carrying the deleted chromosome are not viable. The interest of such a male sterility with a gametophytic determinism for the study of sporophyte-gametophyte relationships is underlined.

  8. Food irradiation and sterilization

    Science.gov (United States)

    Josephson, Edward S.

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25-70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning is achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70-80°C (bacon to 53°C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40°C to -20°C). Radappertozed foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for "wholesomeness" (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effecys of radappertization on the "wholesomeness" characteristics of these foods.

  9. Food irradiation and sterilization

    International Nuclear Information System (INIS)

    Josephson, E.S.

    1981-01-01

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25 to 70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning in achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70 to 80 0 C (bacon to 53 0 C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurrence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40 0 C to -20 0 C). Radappertized foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for 'wholesomeness' (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effects of radappertization on the 'wholesomeness' characteristics of these foods. (author)

  10. The role of meiotic drive in hybrid male sterility.

    Science.gov (United States)

    McDermott, Shannon R; Noor, Mohamed A F

    2010-04-27

    Meiotic drive causes the distortion of allelic segregation away from Mendelian expected ratios, often also reducing fecundity and favouring the evolution of drive suppressors. If different species evolve distinct drive-suppressor systems, then hybrid progeny may be sterile as a result of negative interactions of these systems' components. Although the hypothesis that meiotic drive may contribute to hybrid sterility, and thus species formation, fell out of favour early in the 1990s, recent results showing an association between drive and sterility have resurrected this previously controversial idea. Here, we review the different forms of meiotic drive and their possible roles in speciation. We discuss the recent empirical evidence for a link between drive and hybrid male sterility, also suggesting a possible mechanistic explanation for this link in the context of chromatin remodelling. Finally, we revisit the population genetics of drive that allow it to contribute to speciation.

  11. Documentation requirements for radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation for appr......Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation...... for approval of radiation sterilized products. The impact of these standards on the radiation sterilization is discussed, with special attention given to a few special issues, mainly traceability and uncertainty of measurement results....

  12. Steam sterilization does not require saturated steam

    NARCIS (Netherlands)

    van Doornmalen Gomez Hoyos, J. P.C.M.; Paunovic, A.; Kopinga, K.

    2017-01-01

    The most commonly applied method to sterilize re-usable medical devices in hospitals is steam sterilization. The essential conditions for steam sterilization are derived from sterilization in water. Microbiological experiments in aqueous solutions have been used to calculate various time–temperature

  13. Geographic Variation in Characteristics of Postpartum Women Using Female Sterilization.

    Science.gov (United States)

    White, Kari; Potter, Joseph E; Zite, Nikki

    2015-01-01

    Southern states have higher rates of female sterilization compared with other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women's contraceptive method use between 2006 and 2009. We categorized states according to geographic region: South, Midwest/West, and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. The percentage of postpartum women using sterilization ranged from 5.0% to 9.9% in the Northeast, 8.9% to 10.6% in the Midwest/West, and 11.6% to 22.4% in the South. Women in nearly all subgroups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no differences in the prevalence of sterilization for Blacks compared with Whites in the Northeast (0.76; 95% CI, 0.55-1.06), Midwest/West (0.91; 95% CI, 0.80-1.04), and South (0.96; 95% CI, 0.85-1.07). Women with Medicaid-paid deliveries (vs. private insurance) had a higher prevalence of sterilization in all regions (p sterilization at disproportionately higher rates compared with other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  14. Radiation sterilization of skin allograft

    Science.gov (United States)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  15. Radiation sterilization of skin allograft

    International Nuclear Information System (INIS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-01-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6 . The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2 . The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  16. Development of a novel recessive genetic male sterility system for hybrid seed production in maize and other cross-pollinating crops.

    Science.gov (United States)

    Wu, Yongzhong; Fox, Tim W; Trimnell, Mary R; Wang, Lijuan; Xu, Rui-Ji; Cigan, A Mark; Huffman, Gary A; Garnaat, Carl W; Hershey, Howard; Albertsen, Marc C

    2016-03-01

    We have developed a novel hybridization platform that utilizes nuclear male sterility to produce hybrids in maize and other cross-pollinating crops. A key component of this platform is a process termed Seed Production Technology (SPT). This process incorporates a transgenic SPT maintainer line capable of propagating nontransgenic nuclear male-sterile lines for use as female parents in hybrid production. The maize SPT maintainer line is a homozygous recessive male sterile transformed with a SPT construct containing (i) a complementary wild-type male fertility gene to restore fertility, (ii) an α-amylase gene to disrupt pollination and (iii) a seed colour marker gene. The sporophytic wild-type allele complements the recessive mutation, enabling the development of pollen grains, all of which carry the recessive allele but with only half carrying the SPT transgenes. Pollen grains with the SPT transgenes exhibit starch depletion resulting from expression of α-amylase and are unable to germinate. Pollen grains that do not carry the SPT transgenes are nontransgenic and are able to fertilize homozygous mutant plants, resulting in nontransgenic male-sterile progeny for use as female parents. Because transgenic SPT maintainer seeds express a red fluorescent protein, they can be detected and efficiently separated from seeds that do not contain the SPT transgenes by mechanical colour sorting. The SPT process has the potential to replace current approaches to pollen control in commercial maize hybrid seed production. It also has important applications for other cross-pollinating crops where it can unlock the potential for greater hybrid productivity through expanding the parental germplasm pool. © 2015 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.

  17. Salt Sensitive Tet-Off-Like Systems to Knockdown Primordial Germ Cell Genes for Repressible Transgenic Sterilization in Channel Catfish, Ictalurus punctatus.

    Science.gov (United States)

    Li, Hanbo; Su, Baofeng; Qin, Guyu; Ye, Zhi; Alsaqufi, Ahmed; Perera, Dayan A; Shang, Mei; Odin, Ramjie; Vo, Khoi; Drescher, David; Robinson, Dalton; Zhang, Dan; Abass, Nermeen; Dunham, Rex A

    2017-05-31

    Repressible knockdown approaches were investigated for transgenic sterilization in channel catfish, Ictalurus punctatus . Two primordial germ cell (PGC) marker genes, nanos and dead end , were targeted for knockdown, and an off-target gene, vasa , was monitored. Two potentially salt sensitive repressible promoters, zebrafish adenylosuccinate synthase 2 (ADSS) and zebrafish racemase (Rm), were each coupled with four knockdown strategies: ds-sh RNA targeting the 5' end (N1) or 3' end (N2) of channel catfish nanos , full-length cDNA sequence of channel catfish nanos for overexpression (cDNA) and ds-sh RNA targeting channel catfish dead end (DND). Each construct had an untreated group and treated group with sodium chloride as the repressor compound. Spawning rates of full-sibling P₁ fish exposed or not exposed to the constructs as treated and untreated embryos were 93% and 59%, respectively, indicating potential sterilization of fish and repression of the constructs. Although the mRNA expression data of PGC marker genes were inconsistent in P₁ fish, most F₁ individuals were able to downregulate the target genes in untreated groups and repress the knockdown process in treated groups. The results indicate that repressible transgenic sterilization is feasible for reproductive control of fish, but more data from F₂ or F₃ are needed for evaluation.

  18. Salt Sensitive Tet-Off-Like Systems to Knockdown Primordial Germ Cell Genes for Repressible Transgenic Sterilization in Channel Catfish, Ictalurus punctatus

    Directory of Open Access Journals (Sweden)

    Hanbo Li

    2017-05-01

    Full Text Available Repressible knockdown approaches were investigated for transgenic sterilization in channel catfish, Ictalurus punctatus. Two primordial germ cell (PGC marker genes, nanos and dead end, were targeted for knockdown, and an off-target gene, vasa, was monitored. Two potentially salt sensitive repressible promoters, zebrafish adenylosuccinate synthase 2 (ADSS and zebrafish racemase (Rm, were each coupled with four knockdown strategies: ds-sh RNA targeting the 5′ end (N1 or 3′ end (N2 of channel catfish nanos, full-length cDNA sequence of channel catfish nanos for overexpression (cDNA and ds-sh RNA targeting channel catfish dead end (DND. Each construct had an untreated group and treated group with sodium chloride as the repressor compound. Spawning rates of full-sibling P1 fish exposed or not exposed to the constructs as treated and untreated embryos were 93% and 59%, respectively, indicating potential sterilization of fish and repression of the constructs. Although the mRNA expression data of PGC marker genes were inconsistent in P1 fish, most F1 individuals were able to downregulate the target genes in untreated groups and repress the knockdown process in treated groups. The results indicate that repressible transgenic sterilization is feasible for reproductive control of fish, but more data from F2 or F3 are needed for evaluation.

  19. Energy analysis in sterilization process of food

    International Nuclear Information System (INIS)

    Lee, Dong Sun; Pyun, Yu Ryang

    1986-01-01

    A procedure was developed for predicting energy consumption of batch type thermal processing of food. From mass and energy balance equations various energy usages or losses were estimated for steam sterilization of model food system in No.301-7 can (Φ74.1 x 113.0mm) at three different temperatures. Selected models were 5 % bentonite solution for conductive food and tap water for convective food. Total steam or energy consumption was higher at 110 deg C than at two other higher temperatures (121 deg C and 130 deg C). High energy consumption at low sterilization temperature was mainly due to high bleeding steam energy and convective and radiative heat losses. Thermal energy efficiency was also disscussed. (Author)

  20. Radiation sterilization of plastic packing materials and aseptic packaging

    International Nuclear Information System (INIS)

    Tokuoka, Keiko

    1986-01-01

    In the present day of 'satiation', quality, not quantity, is emphasized for foods, the consumers being oriented toward raw and healthy foodstuff. Aseptic Packaging is excellent means of conservation. While conventionally chemicals have been used for sterilization of packing materials for aseptic packaging, the sterilization by radiation is used in part recently. The following are described : history of aseptic packaging and its features, sterilization by radiation, γ-ray sterilization of large-sized containers, the development of an aseptic packaging system using electron rays, the occurrence of offensive odors from packing materials (comparison of odors from various materials, volatile substances occurring in irradiated polyethylene, influence of film grade upon the formation of carboxylic acid, influence of the irradiation conditions upon the occurrences of volatile substances, volatile substances occurring in the irradiation of bag-in-box packing materials), changes in properties of the packing materials. (Mori, K.)

  1. Steam sterilization costs: a guide for the central service manager.

    Science.gov (United States)

    O'Shaughnessy, K L

    1993-07-01

    The Nassau County Medical Center CS department, East Meadow, New York, was faced with a staff layoff and an increased workload. With some hard thinking and strong staff support, new processes/systems were designed to save time and money. These included outsourcing the sterilization of "easy" trays, instituting a case cart program and developing custom packs. In order to determine where savings could be had, it was first important to examine current costs. By breaking the costs of sterilization processing down into an average cost per load, a formula was developed that helped determine many additional cost comparisons for the department. For example, the cost analysis formula could be used by CS departments to determine the cost-effectiveness of off-site sterilization, to compare using disposable vs. reusable items and to determine costs for EtO sterilization and aeration.

  2. Sterilization in Finland: from eugenics to contraception.

    Science.gov (United States)

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  3. Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)).

    Science.gov (United States)

    Below, Harald; Ryll, Sylvia; Empen, Klaus; Dornquast, Tina; Felix, Stefan; Rosenau, Heike; Kramer, Sebastian; Kramer, Axel

    2010-09-21

    In a cardiac procedure room, ventilated by a ventilation and air-conditioning system with turbulent mixed airflow, a protection zone in the operating area could be defined through visualization of airflows. Within this protection zone, no turbulence was detectable in the room air.Under the given conditions, disinfection of all surfaces including all furniture and equipment after the last operation and subsequent draping of furniture and all equipment that could not be removed from the room with sterile surgical drapes improved the indoor room air quality from cleanroom class C to cleanroom class B. This also allows procedures with elevated requirements to be performed in room class 1b.

  4. Sewage sterilization through gamma radiation

    International Nuclear Information System (INIS)

    Vieira, D.V.; Teixeira, W.M.S.; Silva, F.C.A. da

    2017-01-01

    Lack of sewage treatment and adequate sanitation conditions can contribute to the proliferation of numerous parasitic and infectious diseases in addition to water degradation. Approximately fifty types of infections can be transmitted from a sick to a healthy person through different pathways involving human excreta. Untreated sewage can contaminate water, food, hands, soil, etc. Epidemics of certain diseases such as typhoid, cholera, dysenteries, etc., and countless cases of worms are responsible for high mortality rates in third world countries. In the work the different techniques of sewage treatment by disinfestation and sterilization were analyzed, highlighting the use and the advantages of the gamma radiation as well as the aspects of the radiological protection involved. The technique of sewage sterilization using gamma radiation is a method of controlling bacteria and microorganisms. It is estimated that more than 200 large irradiators are in operation worldwide, of which 5 are in Brazil, for general sterilization use. These facilities use a large amount of radioactive material, in the order of millions of Becquerel, for sterilization with high doses of radiation, which can generate lethal doses in a few minutes. These industrial facilities use Cobalt-60, being classified by the International Atomic Energy Agency - IAEA as Category 1 of high risk, and must possess a high level of radiological protection to carry out the sterilization, standing out the defense in depth. Specific legislation on radiological protection should be drafted for safe work and avoid future radiation accidents

  5. Radiation: A means of sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, R N [International Atomic Energy Agency, Division of Life Sciences, Radiation Biology Section, Vienna (Austria)

    1975-12-15

    The sterilization of medical products by ionizing radiation is a well-established industrial process in a number of technologically advanced countries. It is indeed encouraging to note the rate of growth experienced during the past fifteen years. Starting with the first commercial plant in the early sixties in the USA there are to date more than sixty large facilities of this kind located in USA, Canada, Australia and the countries of Europe including USSR. The geographical distribution of these sterilization plants is rather unbalanced. In this respect Europe is far ahead of the other continents of the world, with about 65% of all sterilization plants, followed by North and South America with 17%, Asia with 8%, Australia and New Zealand with 9% and Africa with only 1%. During the last 10 years the IAEA has actively contributed to the development of radiation sterilization practices and technology in the Member States, with particular emphasis on the developing countries. Such promotional efforts have been made by (a) supporting co-ordinated research to accumulate relevant technical information, (b) organizing scientific meetings and training courses, (c) providing technical expertise in the form of fellowships and expert services, (d) providing technical assistance to conduct market surveys and economic feasibility assessment, (e) scientific publications, including technical manuals and proceedings reports, and (f) assistance in the formulation of an international 'Code of Practice' for standardization of the manufacturing practices for radiation sterilized medical products to meet the specified requirements of the various national Pharmacopoeias and of the international consumer market.

  6. Prospects of radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari

    1992-01-01

    Since radiation sterilization was first introduced in the United States in 1956 in the field of disposable medical devices, it has become an indispensable technique for sterilization because of the following reasons: (1) introduction into dialyzers, (2) introduction in medical device makers, (3) development of disposable medical devices associated with developing both high molecular chemistry and cool sterilization, (4) rationality of sterilization process, and (5) problems of sterilization with ethylene oxide gas. To promote the further development of radiation sterilization, the following items are considered necessary: (1) an increase in the number of facilities for radiation sterilization, (2) recommendation of the international standardization of sterilization method, (3) decrease in radiation doses associated with sterilization, (4) development of electron accelerators and bremsstrahlung equipments for radiation sources, and (5) simplification of sterilization process management. Factors precluding the development of radiation sterilization are: (1) development of other methods than radiation sterilization, (2) development of technique for sterile products, (3) high facility cost, (4) high irradiation cost, (5) benefits and limits of sterilization markets, and (6) influences of materials. (N.K.)

  7. Development of an ideal plant type and male sterility system in sesame suitable for summer rice fallow in the coastal regions of Tamil Nadu

    International Nuclear Information System (INIS)

    Ganesan, J.

    2001-01-01

    In Tamil Nadu, sesame growing on available residual soil moisture after the rice harvest is expanding. In order to achieve higher and more reliable yields under these conditions, a more suitable plant type is needed: with shorter stature and growing period, moderate basal branching and higher productivity. Seeds of 6 varieties were treated with gamma rays, diethyl sulphate (DES) and ethyl methane sulphonate (EMS). The M 1 -M 4 generations were studied and several promising mutants were selected. Among them were also male sterile mutants; it is thought that such mutants will assist in producing hybrid varieties which will give the desired yield breakthrough. (author)

  8. Radiation sterilization of hydrocortisone acetate

    International Nuclear Information System (INIS)

    Charef, A.; Boussaha, A.

    1989-09-01

    The feasibility of using high energy ionizing radiation for the sterilization of hydrocortisone acetate was investigated. Hydrocortisone acetate in the form of powder was exposed to different dose levels of gamma radiation using a Cobalt-60 source. The irradiated samples were examined by various physico-chemical techniques in order to detect possible radiolysis products. It was of interest to know if one could insure sterility and retain biological properties of the drug by suitable choice of radiation dose. The results showed that a 10 KGy radiation dose causes no change in the physico-chemical properties of the drug and is sufficient to obtain contaminant-free product

  9. Plasma Sterilizer with Ultrasonic Cavitation

    International Nuclear Information System (INIS)

    Krasnyj, V.V.; Klosovsky, A.V.; Panasko, T.A.; Shvets, O.M.; Semenova, O.T.; Taran, V.S.; Tereshin, V.I.

    2006-01-01

    A sterilizer consists of ozone generator based on a barrier glow discharge with the flat electrodes covered with dielectric with a high-voltage pulsed power supply of up to 250 W (1). The sterilization camera is equipped with ultrasonic source with the power of 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. Ozone concentration in the aqueous solution was 6 mg/liter with ozone concentration at the output of ozone generator 30 mg/liter. The complete inactivation of spores took 15 min

  10. The possibility of gamma ray sterilization by using ITU TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Bilge, A.N.; Tugrul, B.; Yavuz, H.

    1988-01-01

    Gamma rays are one of the effective method for sterilization which is preferred for a long time. Generally Co-60 radioisotope sources betatrons or accelerators are used for the sterilization. In this work, it was aimed to find the possibilities of the sterilization by gamma rays obtained in ITU TRIGA Mark-II radial tube. Radiation dosages are measured in the radial tube and several medical products are irradiated. Irradiation is arranged according to the desired dosages. Irradiated sterilized goods (mainly medical products) tested and checked at the Governmental Medical Health Center and results compared with literature. It can be seen that this kind of irradiation is a good tool for sterilization. Unfortunately, because of the stability of the radial tube and impracticality of the system it is rather difficult to compete with industrial system using Co-60 and accelerators. Nevertheless, this type of irradiation is also applicable for the purpose of the sterilization by using ITU TRIGA Mark II. (author)

  11. Male and female sterility in Zambia

    Directory of Open Access Journals (Sweden)

    Athena Pantazis

    2014-02-01

    Full Text Available Background: Population measures of sterility are traditionally constructed for women, despite fertility and sterility being conditions of the couple. Estimates of male sterility provide insight into population-level sterility, and complement estimates based solely on women. Objective: This study seeks to estimate male sterility for the Gwembe Tonga of Zambia using male birth histories collected by the Gwembe Tonga Research Project from 1957 to 1995, while providing context by estimating female sterility for the Gwembe Tonga, as well as female sterility in all of Zambia, from Zambian DHS data (1992, 1997, 2001-02, and 2007. Methods: Sterility is measured using the Larson-Menken subsequently infertile indicator. Estimates are produced using discrete time event history analysis. Results: The odds of sterility were higher for women than men, though women's odds of sterility were only 1.5 times that of men's in the middle reproductive years. The odds of sterility increased steadily with age for both men and women, and across all datasets. However, women's sterility increased much more sharply with age than men's did, and women's odds of sterility were higher than men's at all reproductive ages.

  12. Sterile neutrino constraints from cosmology

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, Georg G.

    2012-01-01

    The presence of light particles beyond the standard model's three neutrino species can profoundly impact the physics of decoupling and primordial nucleosynthesis. I review the observational signatures of extra light species, present constraints from recent data, and discuss the implications of po...... of possible sterile neutrinos with O(eV)-masses for cosmology....

  13. Sterile Neutrino Search with MINOS

    International Nuclear Information System (INIS)

    Devan, Alena V.

    2015-01-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm 2 . An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, Δm s 2 ~ 1 eV 2 . The results of the 2013 sterile neutrino search are presented here.

  14. Sterility test by radiometric technique

    International Nuclear Information System (INIS)

    Faruq, Muhammad

    1980-01-01

    Sterility test of pharmaceuticals can be carried out by the application of pharmacopoeia and radiometric technique. In Indonesia the application of pharmacopoeia technique is carried out through liquid germination for aerobacteria and for fungus and yeast. Radiometric technique is applied to autotrop and heterotrop bacteria. (SMN)

  15. Sterile Neutrino Search with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Devan, Alena V. [College of William and Mary, Williamsburg, VA (United States)

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  16. Sterilization can change properties of bioceramics

    International Nuclear Information System (INIS)

    Willmann, G.

    2003-01-01

    Bioceramics made of bioinert alumina or zirconia and bioactive hydroxyapatite are well established implant materials. Implants have to be cleaned and sterilized. When sterilized some bioceramics change their color. This may effect their properties. No decrease of mechanical strength is observed when sterilizing alumina and the novel ceramic biocomposite AMC (Alumina Matrix Composite) with steam or Co 60 Gamma irradiation. When sterilizing Y-TZP zirconia with steam a decrease of strength is observed. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [de

  17. Radiation sterilization: an industrial process

    International Nuclear Information System (INIS)

    Ley, F.J.

    1975-01-01

    A new dimension has been added to the use of radiation in the medical field with the introduction of radiation as a sterilizing agent. Its use in diagnosis through radioactive tracers or X-rays and in therapy administered with the most sophisticated of electrical machines or radioisotope units, is familiar in the hospital world, being well established therein. In contrast, the application of radiation sterilization is in industry where the installation of large radiation sources is already commonplace in many countries. The beginnings in the early 1950's centered on the Van de Graaff machine and linear accelerators and the pioneering efforts of Ethicon Inc. here in the United States must be recognized. However, although sterilization with electron beams is still current practice in a number of plants, the use of gamma rays from cobalt-60 is preferred. The first steps in this direction were taken by the U.K.A.E.A. which, in common with similar organizations elsewhere, was attempting to exploit the tremendous potential for cobalt-60 production arising through the rapid construction of nuclear reactors. The first full-scale commercial gamma plant was commissioned in the U.K. in 1960. It reached a loading of 500,000 curies before its demolition after twelve years of operation. The process gained rapid acceptance within industry and approval by health authorities because it provided a ''cold'' sterilization method combining the property of lethal effect with penetration. Its immediate impact occurred in the introduction of disposable products making it possible, for example, to use heat-labile plastics and new packaging materials and package designs. Certainly, the technique has proved complementary to sterilization methods based on heat and to the use of chemical agents, in particular ethylene oxide gas

  18. Reionization in sterile neutrino cosmologies

    Science.gov (United States)

    Bose, Sownak; Frenk, Carlos S.; Hou, Jun; Lacey, Cedric G.; Lovell, Mark R.

    2016-12-01

    We investigate the process of reionization in a model in which the dark matter is a warm elementary particle such as a sterile neutrino. We focus on models that are consistent with the dark matter decay interpretation of the recently detected line at 3.5 keV in the X-ray spectra of galaxies and clusters. In warm dark matter models, the primordial spectrum of density perturbations has a cut-off on the scale of dwarf galaxies. Structure formation therefore begins later than in the standard cold dark matter (CDM) model and very few objects form below the cut-off mass scale. To calculate the number of ionizing photons, we use the Durham semi-analytic model of galaxy formation, GALFORM. We find that even the most extreme 7 keV sterile neutrino we consider is able to reionize the Universe early enough to be compatible with the bounds on the epoch of reionization from Planck. This, perhaps surprising, result arises from the rapid build-up of high redshift galaxies in the sterile neutrino models which is also reflected in a faster evolution of their far-UV luminosity function between 10 > z > 7 than in CDM. The dominant sources of ionizing photons are systematically more massive in the sterile neutrino models than in CDM. As a consistency check on the models, we calculate the present-day luminosity function of satellites of Milky Way-like galaxies. When the satellites recently discovered in the Dark Energy Survey are taken into account, strong constraints are placed on viable sterile neutrino models.

  19. Compodock, a new device for sterile docking

    NARCIS (Netherlands)

    van der Meer, P. F.; Biekart, F. T.; Pietersz, R. N.; Rebers, S. P.; Reesink, H. W.

    2000-01-01

    BACKGROUND: A new device for sterile docking, the Compodock (Fresenius NPBI Transfusion Technology), was developed for connecting PVC tubing for medical use while maintaining sterility. STUDY DESIGN AND METHODS: Sterility of the connections was assessed by welding tubing with a heavy exterior

  20. Segregation of male-sterility alleles across a species boundary.

    Science.gov (United States)

    Weller, S G; Sakai, A K; Culley, T M; Duong, L; Danielson, R E

    2014-02-01

    Hybrid zones may serve as bridges permitting gene flow between species, including alleles influencing the evolution of breeding systems. Using greenhouse crosses, we assessed the likelihood that a hybrid zone could serve as a conduit for transfer of nuclear male-sterility alleles between a gynodioecious species and a hermaphroditic species with very rare females in some populations. Segregation patterns in progeny of crosses between rare females of hermaphroditic Schiedea menziesii and hermaphroditic plants of gynodioecious Schiedea salicaria heterozygous at the male-sterility locus, and between female S. salicaria and hermaphroditic plants from the hybrid zone, were used to determine whether male-sterility was controlled at the same locus in the parental species and the hybrid zone. Segregations of females and hermaphrodites in approximately equal ratios from many of the crosses indicate that the same nuclear male-sterility allele occurs in the parent species and the hybrid zone. These rare male-sterility alleles in S. menziesii may result from gene flow from S. salicaria through the hybrid zone, presumably facilitated by wind pollination in S. salicaria. Alternatively, rare male-sterility alleles might result from a reversal from gynodioecy to hermaphroditism in S. menziesii, or possibly de novo evolution of male sterility. Phylogenetic analysis indicates that some species of Schiedea have probably evolved separate sexes independently, but not in the lineage containing S. salicaria and S. menziesii. High levels of selfing and expression of strong inbreeding depression in S. menziesii, which together should favour females in populations, argue against a reversal from gynodioecy to hermaphroditism in S. menziesii. © 2014 The Authors. Journal of Evolutionary Biology © 2014 European Society For Evolutionary Biology.

  1. Recurrent population improvement of rice breeding facilitated with male sterility

    International Nuclear Information System (INIS)

    Fujimaki, Hiroshi

    1982-01-01

    A new rice breeding system has been developed, making use of genic male sterility to utilize diverse breeding materials and to promote genetic recombination. In this system, recurrent selection technique and introgressive hybridization were used to increase the frequencies of producing desired genotypes and to improve the population in succession. To promote genetic recombination by the recurrent selection technique, intermating within the population is necessary, and to introduce useful germ plasms by the introgressive hybridization, back crossing with new genetic material is necessary. These can be done efficiently by using the recessive alleles for male sterility, and the representative models for thisF type of breeding were presented. (Kaihara, S.)

  2. Radiosterilization or sterilization by steam. Procedures for sterilization of spices

    International Nuclear Information System (INIS)

    Warmbold, J.

    1994-01-01

    The article compares two different methods for the sterilization of spices, namely radiosterilization and sterilization with steam. The first method applies ionizing radiation which can alter the chemical composition of the products. Tests have shown, however, that radiation doses up to 10 kGy will not induce the formation of carcinogenic agents in the foodstuffs, or of toxic substances, and thus are a wholesome method of preservation. Any modifications of taste, color or smell, or loss of vitamins, can be avoided by proper dose control and standard irradiation conditions. Sterilization by steam is a method achieving substantial suppression of the formation of germs, aerobic spores, yeasts, mould, and gramnegative germs, while preserving in most cases the essential oils. It may result in sensoric alterations, i.e affect the color, smell or taste, but in general the spices thus treated preserved their characteristic properties. The method is a good alternative to radiosterilization. The article adds some concluding information on mandatory labelling of irradiated food imported from third countries

  3. Plant's sterilization rule for fertile women cited.

    Science.gov (United States)

    1979-01-01

    The American Cyanamid Corporation has been cited by the Occupational Safety and Health Administration (OSHA) for violating federal law by requiring female employees of childbearing age to be sterilized in order to continue working in areas of the plant where they would be exposed to high levels of airborne lead. High levels of airborne lead can cause damage to workers' reproductive systems and be responsible for birth defects in fetuses. The OSHA charged that American Cyanamid's policy constituted a "willful violation" of the 1970 Occupational Safety and Health Act. The Act requires employers to provide employment that is free from recognized hazards likely to cause death or physical harm. According to OSHA, the Act does not allow an employer to eliminate the hazard by compelling employees to choose between losing their jobs and undergoing sterilization. The reproductive health of workers is considered a valid part of OSHA's regulatory concern. The citation, which carries a $10,000 fine, grew out of a complaint that was filed by the Oil, Chemical and Atomic Workers Union on behalf of 5 female workers working in the lead pigment division of the company's Willow Island, West Virginia plant. The 5 employees alleged that they had themselves sterilized to avoid being transferred to other and possibly lower paying janitorial jobs or losing thier jobs completely. The company is appealing the citation. The union has also filed a complaint with the Equal Employment Opportunity Commission charging American Cyanamid with sex discrimination, since only the women workers are at risk of being transferred to lower paying jobs.

  4. Female Sterilization and Poor Mental Health: Rates and Relatedness among American Indian and Alaska Native Women.

    Science.gov (United States)

    Cackler, Christina J J; Shapiro, Valerie B; Lahiff, Maureen

    2016-01-01

    To describe the reproductive and mental health of American Indian and Alaska Native (AI/AN) women, an understudied population. Data from the 2004 Behavioral Risk Factor Surveillance System survey were analyzed to determine the 1) prevalence of female sterilization among a nationally representative sample of reproductive age AI/AN women and 2) the association of female sterilization and poor mental health among AI/AN women compared with non-Hispanic White, non-Hispanic Black, and Hispanic women. Nearly 25% of AI/AN women reported female sterilization, a prevalence higher than the comparison racial/ethnic groups (p women reporting female sterilization had nearly 2.5 times the odds of poor mental health compared with AI/AN women not reporting female sterilization (p = .001). The same magnitude of relationship between female sterilization and poor mental health was not found for non-Hispanic White, non-Hispanic Black, and Hispanic women. The prevalence of female sterilization is greater among AI/AN women compared with non-Hispanic White, non-Hispanic Black, and Hispanic women, and AI/AN women reporting female sterilization have higher odds of reporting poor mental health. Common cultural experiences, such as a shared ancestral history of forced sterilizations, may be relevant, and could be considered when providing reproductive and mental health services to AI/AN women. Copyright © 2016 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  5. Mirror model for sterile neutrinos

    International Nuclear Information System (INIS)

    Berezinsky, Veniamin; Narayan, Mohan; Vissani, Francesco

    2003-01-01

    Sterile neutrinos are studied as subdominant contribution to solar neutrino physics. The mirror-matter neutrinos are considered as sterile neutrinos. We use the symmetric mirror model with gravitational communication between mirror and visible sectors. This communication term provides mixing between visible and mirror neutrinos with the basic scale μ=v EW 2 /M Pl =2.5x10 -6 eV, where v EW =174 GeV is the vacuum expectation value of the standard electroweak group and M Pl is the Planckian mass. It is demonstrated that each mass eigenstate of active neutrinos splits into two states separated by small Δm 2 . Unsuppressed oscillations between active and sterile neutrinos (ν a ↔ν s ) occur only in transitions between each of these close pairs ('windows'). These oscillations are characterized by very small Δm 2 and can suppress the flux and distort spectrum of pp-neutrinos in detectable way. The other observable effect is anomalous seasonal variation of neutrino flux, which appears in LMA solution. The considered subdominant neutrino oscillations ν a ↔ν s can reveal itself as big effects in observations of supernova neutrinos and high-energy (HE) neutrinos. In the case of HE neutrinos they can provide a very large diffuse flux of active neutrinos unconstrained by the e-m cascade upper limit

  6. Cross-cultural attitudes toward voluntary sterilization.

    Science.gov (United States)

    Hong, S

    1985-06-01

    . Cultural traits such as machismo and son preference tend to be associated with negative attitudes toward sterilization; yet, VS prevalence is high in China and Panama despite the presence of a strong preference for sons in the former country and of machismo attitudes in the latter country. Acceptance of VS as a form of birth control appears to be increasing throughout the world. This trend will probably become stronger as improvements are made in VS technologies and Vs delivery systems.

  7. Processing laboratory of radio sterilized biological tissues

    International Nuclear Information System (INIS)

    Aguirre H, Paulina; Zarate S, Herman; Silva R, Samy; Hitschfeld, Mario

    2005-01-01

    The nuclear development applications have also reached those areas related to health. The risk of getting contagious illnesses through applying biological tissues has been one of the paramount worries to be solved since infectious illnesses might be provoked by virus, fungis or bacterias coming from donors or whether they have been introduced by means of intermediate stages before the use of these tissues. Therefore it has been concluded that the tissue allografts must be sterilized. The sterilization of medical products has been one of the main applications of the ionizing radiations and that it is why the International Organization of Atomic Energy began in the 70s promoting works related to the biological tissue sterilization and pharmaceutical products. The development of different tissue preservation methods has made possible the creation of tissue banks in different countries, to deal with long-term preservation. In our country, a project was launched in 1998, 'Establishment of a Tissue Bank in Latino america', this project was supported by the OIEA through the project INT/ 6/ 049, and was the starting of the actual Processing Laboratory of Radioesterilized Biological Tissues (LPTR), leaded by the Chilean Nuclear Energy Commission (CCHEN). This first organization is part of a number of entities compounding the Tissue Bank in Chile, organizations such as the Transplantation Promotion Corporation hospitals and the LPTR. The working system is carried out by means of the interaction between the hospitals and the laboratory. The medical professionals perform the procuring of tissues in the hospitals, then send them to the LPTR where they are processed and sterilized with ionizing radiation. The cycle ends up with the tissues return released to the hospitals, where they are used, and then the result information is sent to the LPTR as a form of feedback. Up to now, human skin has been processed (64 donors), amniotic membranes (35 donors) and pig skin (175 portions

  8. Gender variation, partial male sterility and labile sex expression in gynodioecious Plantago coronopus

    NARCIS (Netherlands)

    Koelewijn, HP; VanDamme, JMM

    Gynodioecy is a breeding system consisting of male steriles (MS, females) and hermaphrodites (H). There is however within such sq stems a third, often neglected, class of partially male sterile plants (PMS), i.e. plants with an intermediate sex expression. In natural populations of Plantago

  9. Gender variation, partial male sterility and labile sex expression in gynodioecious Plantago coronopus

    NARCIS (Netherlands)

    Koelewijn, H.P.; Van Damme, J.M.M.

    1996-01-01

    Gynodioecy is a breeding system consisting of male steriles (MS, females) and hermaphrodites (H). There is however within such sq stems a third, often neglected, class of partially male sterile plants (PMS), i.e. plants with an intermediate sex expression. In natural populations of Plantago

  10. Genetic analysis of male sterility genes in different A and B sorghum ...

    African Journals Online (AJOL)

    Hybrid seed production requires use of cytoplasmic male sterility (CMS). Without this system, hybrid seed production would not be economically feasible. There is, therefore, need for developing A and B sorghum lines, as an essential step for development of hybrid sorghum industry. A genetic study of male sterility in ...

  11. Plasma Sterilization: New Epoch in Medical Textiles

    Science.gov (United States)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  12. Regret following female sterilization in Slovenia.

    Science.gov (United States)

    Becner, Anja; Turkanović, Anela Bečić; But, Igor

    2015-07-01

    To estimate the regret rate and risk factors for regret among women who have undergone sterilization. A retrospective study was conducted among all women who underwent a sterilization procedure at the University Medical Center Maribor, Maribor, Slovenia, in 2008-2012. Identified women were contacted and asked to complete an online questionnaire assessing regret and symptoms associated with depression. Among 714 identified women, 308 (43.1%) completed the questionnaire. Four (1.3%) participants reported regret, and 9 (2.9%) reported that they would not opt for sterilization again, all of whom had post-sterilization problems. Such problems were significantly associated with participants reporting that they would not opt for sterilization again (P=0.003). Additionally, women who would not choose sterilization again had significantly higher scores on the depressive scale used than did those who would undergo sterilization again (P=0.028). Few women report regret after tubal sterilization in Slovenia. However, an additional consultation on post-sterilization problems and depressive disorder before sterilization might minimize the risk of regret. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  13. Women plan condom use after sterilization.

    Science.gov (United States)

    1998-12-01

    Sexual sterilization is highly effective in preventing pregnancy, but it does not protect against sexually transmitted diseases (STDs). People who accept sterilization as their method of family planning therefore need to be encouraged to protect themselves against HIV/AIDS and STDs even after they have been sterilized. Since women return less often to family planning providers following their sterilization procedure, they need to be advised to protect themselves against HIV and STDs before the sterilization is performed. 42% of the 2782 women who underwent tubal sterilizations at the Baylor College of Medicine in Houston during 1991-96 indicated their intention in a cross-sectional study to use condoms after sterilization. 20% of all respondents, aged 18-51 years, had a known risk factor for HIV, and almost 25% reported regular condom use for contraception or disease protection during the 3 months before sterilization. Planned condom use increased from 32% in 1991 to 51% in 1996, irrespective of age, marital status, or ethnic background. Of the 646 women who used condoms before being sterilized, almost half indicated no plans to do so after the procedure. The following factors were associated with condom use: relatively younger age, black ethnicity, unmarried status, history of previous STD, no steady partner, having a higher number of previous sex partners, past use of condoms to prevent disease transmission, and lack of partner involvement in the decision to undergo sterilization.

  14. The sterile immune response during hepatic ischemia/reperfusion

    NARCIS (Netherlands)

    van Golen, Rowan F.; van Gulik, Thomas M.; Heger, Michal

    2012-01-01

    Hepatic ischemia and reperfusion elicits an immune response that lacks a microbial constituent yet poses a potentially lethal threat to the host. In this sterile setting, the immune system is alarmed by endogenous danger signals that are release by stressed and dying liver cells. The detection of

  15. Birth planning and sterilization in China.

    Science.gov (United States)

    Short, S E; Linmao, M; Wentao, Y

    2000-11-01

    Sterilization is the most prevalent method of contraception in China. Approximately half of all women of reproductive age report that they or their husbands are sterilized. Using data from the China Health and Nutrition Survey we describe patterns of sterilization in eight Chinese provinces. With a discrete-time event history model we investigate the link between characteristics of local birth planning policy and the risk of sterilization. After controlling for parity, the risk of sterilization is highest in communities where birth planning policy is least strong as measured by exceptions to the one-child policy. These results suggest that couples with more flexibility in family building may have less control over contraceptive method use. Other factors affecting the risk of sterilization are a woman's age, parity, and whether or not she has a son. Our results emphasize the importance of taking into account multiple dimensions of reproductive behaviour when assessing one-child policy changes.

  16. Sterilization of heparinized cuprophan hemodialysis membranes

    OpenAIRE

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated. Sterilization did not result in a release of heparin or heparin fragments from heparinized Cuprophan. Sterilization of heparinized Cuprophan by means of EtO exposure and gamma irradiation induced a slight, i...

  17. EB surface sterilization of food material

    International Nuclear Information System (INIS)

    Kaneko, H.; Mizutani, A.; Kato, K.; Nishikimi, T.; Taniguchi, S.

    2001-01-01

    In this paper, we introduce a food irradiation with low energetic, lower than 300keV, electrons (so-called SOFT ELECTRON) as a rather new method of food sterilization. It is also a physical sterilization method, and free from the problems mentioned above. Low energetic electrons have small penetration power (50-200micron) through raw materials, and by selecting a proper energy of electrons we can sterilize only the surfaces or skins of target materials

  18. Probabilistic model for sterilization of food

    International Nuclear Information System (INIS)

    Chepurko, V.V.; Malinovskij, O.V.

    1986-01-01

    The probabilistic model for radiation sterilization is proposed based on the followng suppositions: (1) initial contamination of a volume unit of the sterilized product m is described by the distribution of the probabilities q(m), (2) inactivation of the population from m of microorganisms is approximated by Bernoulli test scheme, and (3) contamination of unit of the sterilized product is independent. The possibility of approximation q(m) by Poisson distribution is demonstrated. The diagrams are presented permitting to evaluate the dose which provides the defined reliability of sterilization of food for chicken-gnotobionts

  19. Sterile neutrino dark matter with supersymmetry

    Science.gov (United States)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  20. Currently available devices for female sterilization.

    Science.gov (United States)

    Chapman, Lynne; Magos, Adam

    2005-09-01

    Sterilization is now the method of family planning most commonly used in the world. Over the last 150 years, research has evolved in the search for the ideal method of female sterilization. The procedure should ideally have high efficacy, be readily accessible and be personally and culturally acceptable. The method should be simple, quick, easily learned and be able to be performed in an outpatient setting without general anesthesia. The most common and effective method for sterilization has, thus far, been via the laparoscopic route. Hysteroscopic sterilization, however, potentially fulfills many of these ideal criteria, but until recently has remained more of a concept than a reality.

  1. Genetic basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Robinson, A.S.

    2014-01-01

    The use of the sterile insect technique for insect control relies on the introduction of sterility in the females of the wild population. This sterility is produced following the mating of these females with released males carrying, in their sperm, dominant lethal mutations that have been induced by ionizing radiation. As well as radiation-induced sterility, natural mechanisms can be recruited, especially the use of hybrid sterility. Radiation is usually one of the last procedures that insects undergo before leaving mass-rearing facilities for release in the field. It is essential that the dosimetry of the radiation source be checked to ensure that all the insects receive the required minimum dose. A dose should be chosen that maximizes the level of introduced sterility in the wild females in the field. Irradiation in nitrogen can provide protection against the detrimental somatic effects of radiation. Currently, the development of molecular methods to sterilize pest insects in the field, by the release of fertile insects carrying trans genes, is very much in vogue. It is concluded that using a physical process, such as radiation, will always have significant advantages over genetic and other methods of sterilization for the large-scale application of the sterile insect technique. (author)

  2. Introduction, maintenance and utilization of male sterility in leek (Allium ampeloprasum L.) = [Inductie, handhaving en gebruik van mannelijke steriliteit in prei (Allium ampeloprasum L.)

    NARCIS (Netherlands)

    Silvertand, B.

    1996-01-01


    This thesis describes research work performed in leek in relation to efforts to obtain or exploit a male sterility system for hybrid leek breeding. Male sterile plants can be found in every leek cultivar. The male sterility trait can be explained by a nuclear monogenic inheritance or by a

  3. MR imaging of ''sterilized'' lymphoma

    International Nuclear Information System (INIS)

    Zerhouni, E.A.; Fishman, E.K.; Jones, R.; Siegelman, S.S.; Soulen, R.L.

    1986-01-01

    Residual masses are commonly observed after effective therapy in patients with lymphoma. These masses may be sterile but their presence poses a management problem, inasmuch as there is no adequate means of distinguishing sterile from active masses. The potential role of MR imaging in this context was evaluated by studying a group of 15 patients with stable, residual, presumably inactive masses (as determined from CT) and comparing the MR imaging findings in patients with newly diagnosed, untreated or recently treated lymphoma. All patients underwent an MR imaging examination consisting of one short repetition time (TR), short echo time (TE) (T1-weighted) sequence and one long TR, long TE(T2-weighted) sequence. The signal intensity of the masses was compared with that of fat in each patient, for each sequence. In selected patients, sequential examinations showed a progressive evolution toward the inactive pattern over a period of several weeks. Active and inactive disease are well depicted on T1-weighted sequences but are not distinguishable from each other. On T2-weighted sequences active disease is poorly demonstrated because the lesions are isointense with fat, whereas inactive masses remain clearly identifiable because they are of much lower signal intensity than fat

  4. Control and Constraint for Low-Income Women Choosing Outpatient Sterilization

    Science.gov (United States)

    Leyser-Whalen, Ophra; Berenson, Abbey B.

    2012-01-01

    Little is known about Hispanics and their contraceptive choices in general, with some past studies detailing non-consensual sterilization. This article is based on interviews with a mostly Hispanic sample of 44 women being sterilized at a public clinic in southeast Texas with the Essure device, which entails a new outpatient sterilization procedure. These women cited relationship factors, wanting to better their and their children’s lives, and past reproductive histories as reasons for deciding on sterilization. They specifically chose Essure as a result of an apprehension of surgery and potential side effects from tubal ligation. Their choices, however, were limited by larger structural factors of work, family, the political economy, and the health care system. We conclude that this new sterilization technique provided more contraceptive choices for these women, yet more contraceptive decision making autonomy, as well as more equitable social structures, are still needed. PMID:23761929

  5. Hybrid male sterility in rice controlled by interaction between divergent alleles of two adjacent genes.

    Science.gov (United States)

    Long, Yunming; Zhao, Lifeng; Niu, Baixiao; Su, Jing; Wu, Hao; Chen, Yuanling; Zhang, Qunyu; Guo, Jingxin; Zhuang, Chuxiong; Mei, Mantong; Xia, Jixing; Wang, Lan; Wu, Haibin; Liu, Yao-Guang

    2008-12-02

    Sterility is common in hybrids between divergent populations, such as the indica and japonica subspecies of Asian cultivated rice (Oryza sativa). Although multiple loci for plant hybrid sterility have been identified, it remains unknown how alleles of the loci interact at the molecular level. Here we show that a locus for indica-japonica hybrid male sterility, Sa, comprises two adjacent genes, SaM and SaF, encoding a small ubiquitin-like modifier E3 ligase-like protein and an F-box protein, respectively. Most indica cultivars contain a haplotype SaM(+)SaF(+), whereas all japonica cultivars have SaM(-)SaF(-) that diverged by nucleotide variations in wild rice. Male semi-sterility in this heterozygous complex locus is caused by abortion of pollen carrying SaM(-). This allele-specific gamete elimination results from a selective interaction of SaF(+) with SaM(-), a truncated protein, but not with SaM(+) because of the presence of an inhibitory domain, although SaM(+) is required for this male sterility. Lack of any one of the three alleles in recombinant plants does not produce male sterility. We propose a two-gene/three-component interaction model for this hybrid male sterility system. The findings have implications for overcoming male sterility in inter-subspecific hybrid rice breeding.

  6. Gamma sterilization of disposable medical products (DMP's)

    International Nuclear Information System (INIS)

    Brinston, R.M.

    1990-01-01

    Ten million cubic meters (361 million cubic feet) of disposable medical products (DMP) and related health care items are estimated to be sterilized in the world. In this paper, current conditions and perspectives of gamma sterilization is discussed in comparison with ethylene oxide gas and electron beams. Of the total sterilization estimates for DMP, 2.8 million cubic meters (99 million cubic feet) are sterilized with gamma radiation, with a market share of 27%. Gamma radiation is becoming increased from both general market growth and the introduction of new products, as well as the conversion of product from ethylene oxide gas to cobalt-60. Regulatory pressures, legal considerations, and increasing publicity surrounding ethylene oxide usage are encouraging manufactures to switch to gamma radiation. Gamma's performance features include: no temperature change during the sterilization, high penetration, even through hermetically sealed packages, no residues, and no post-sterilization treatment or quarantine period. Gamma sterilization is economically beneficial in large volumes of product. Cost saving to the end user of gamma sterilization has meant lower minimum dose levels than 25 KGy. Despite of an increasingly accepted gamma radiation, there are still four factors to be considered, including cobalt-60 availability, price, transportation, and disposal. The price of cobalt-60 is based on neutron cost. In the future, cobalt-60 price is expected to be flat and enables gamma processing to become even more competitive with other sterilization methods. Gamma radiation using cobalt-60 has been proven as a safe, effective, and cost-competitive sterilization method for treating DMP and related health care items. It's wide use and many processing advantages will continue to make it a preferred sterilization method. (N.K.)

  7. Heavy Sterile Neutrino in Dark Matter Searches

    Directory of Open Access Journals (Sweden)

    Paraskevi C. Divari

    2018-01-01

    Full Text Available Sterile neutrinos are possible dark matter candidates. We examine here possible detection mechanisms, assuming that the neutrino has a mass of about 50 keV and couples to the ordinary neutrino. Even though this neutrino is quite heavy, it is nonrelativistic with a maximum kinetic energy of 0.1 eV. Thus new experimental techniques are required for its detection. We estimate the expected event rate in the following cases: (i measuring electron recoil in the case of materials with very low electron binding; (ii low temperature crystal bolometers; (iii spin induced atomic excitations at very low temperatures, leading to a characteristic photon spectrum; (iv observation of resonances in antineutrino absorption by a nucleus undergoing electron capture; (v neutrino induced electron events beyond the end point energy of beta decaying systems, for example, in the tritium decay studied by KATRIN.

  8. [Mechanisms of urinary tract sterility maintenance].

    Science.gov (United States)

    Okrągła, Emilia; Szychowska, Katarzyna; Wolska, Lidia

    2014-06-02

    Physiologically, urine and the urinary tract are maintained sterile because of physical and chemical properties of urine and the innate immune system's action. The urinary tract is constantly exposed to the invasion of microorganisms from the exterior environment, also because of the anatomical placement of the urethra, in the vicinity of the rectum. Particularly vulnerable to urinary tract infections (UTI) are women (an additional risk factor is pregnancy), but also the elderly and children. The main pathogens causing UTI are bacteria; in 70-95% of cases it is the bacterium Escherichia coli. Infections caused by viruses and fungi are less common and are associated with decreased immunity, pharmacotherapy, or some diseases. Bacteria have evolved a number of factors that facilitate the colonization of the urinary tract: the cover and cell membrane antigens O and K1, lipopolysaccharide (LPS), fimbriae, pile and cilia. On the other hand, the human organism has evolved mechanisms to hinder colonization of the urinary tract: mechanisms arising from the anatomical structure of the urinary tract, the physicochemical properties of the urine and the activity of the innate immune system, also known as non-specific, which isolates and destroys pathogens using immunological processes, and the mechanisms for release of antimicrobial substances such as Tamm-Horsfall protein, mucopolysaccharides, immunoglobulins IgA and IgG, lactoferrin, lipocalin, neutrophils, cytokines and antimicrobial peptides. This review aims to analyze the state of knowledge on the mechanisms to maintain the sterility of the urinary tract used by the human organism and bacterial virulence factors to facilitate the colonization of the urinary tract.

  9. Eugenics and Involuntary Sterilization: 1907-2015.

    Science.gov (United States)

    Reilly, Philip R

    2015-01-01

    In England during the late nineteenth century, intellectuals, especially Francis Galton, called for a variety of eugenic policies aimed at ensuring the health of the human species. In the United States, members of the Progressive movement embraced eugenic ideas, especially immigration restriction and sterilization. Indiana enacted the first eugenic sterilization law in 1907, and the US Supreme Court upheld such laws in 1927. State programs targeted institutionalized, mentally disabled women. Beginning in the late 1930s, proponents rationalized involuntary sterilization as protecting vulnerable women from unwanted pregnancy. By World War II, programs in the United States had sterilized approximately 60,000 persons. After the horrific revelations concerning Nazi eugenics (German Hereditary Health Courts approved at least 400,000 sterilization operations in less than a decade), eugenic sterilization programs in the United States declined rapidly. Simplistic eugenic thinking has faded, but coerced sterilization remains widespread, especially in China and India. In many parts of the world, involuntary sterilization is still intermittently used against minority groups.

  10. Cosmology seeking friendship with sterile neutrinos

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, G.G.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile ...

  11. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    PRINCIPLES OF HEAT STERILIZATION. IN DENTAL PRACTICE. W.H. van Palenstein Helderman. Department of Community and Preventive Dentistry,. Faculty of Dentistry, Muhimbili University College of Health Sciences,. Dar es Salaam, Tanzania. Introduction. Sterilization is defined as the destruction of all forms of life ...

  12. Current Sterilization Protocols-An Orthodontic Perspective

    Directory of Open Access Journals (Sweden)

    Abraham Vinod Korath

    2010-01-01

    Part I of this article focuses on the working principles of various methods of sterilization with an appraisalof their effects on orthodontic instruments. Additionally,contributory factors of instrument damage is enumerated to emphasis the importance of adhering to precise protocols and manufacturer recommendations as well as in alleviating some misconceptions about sterilization induced instrument damage.

  13. Light Sterile Neutrinos: A White Paper

    DEFF Research Database (Denmark)

    Abazajian, K. N.; Acero, M. A.; Agarwalla, S. K.

    2012-01-01

    This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.......This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data....

  14. Male sterile mutant in Vigna radiata

    International Nuclear Information System (INIS)

    Pande, Kalpana; Raghuvanshi, S.S.

    1987-01-01

    Single and combined treatment of γ-rays and 0.25 per cent EMS were tried on Vigna radiata variety K851. A male sterile mutant was isolated in M 2 generation. Experiments indicated male sterility to be recessive and monogenic in nature. 6 figures. (author)

  15. Sodium hypochlorite sterilization of culture medium in ...

    African Journals Online (AJOL)

    With the purpose of finding an alternative to thermal sterilization, this research aimed at assessing the efficiency and ideal concentration of sodium hypochlorite for sterilization of culture media and glassware used during rooting of micropropagated Gerbera hybrida cv. Essandre. Two experiments were carried out. In the first ...

  16. Study of fieldbus technology applied in a sterilization plant control and safety systems; Estudo de aplicacao de tecnologia 'fieldbus' nos sistemas de controle e seguranca de uma planta de radioesterilizacao

    Energy Technology Data Exchange (ETDEWEB)

    Karam Junior, Dib

    2000-07-01

    Several sterilization processes have been used in these years for treatment of countless products. Some processes use high temperatures, thermal shocks and chemical agents. With the discovery of the ionizing radiation and its posterior technological developments turned possible application of that process, in 1960, also in the the sterilization, denominated radiation sterilization. This process became also applied in another areas of health and industrial as food conservation, gemstones enhancement and others. The radiation sterilization requests an effective control and it needs a high level of safety. The commercial use of the computers applied in industrial automation provides and the domain of new technologies in this field provides new applications then new designs now is possible. The Fieldbus technology, a new digital communication protocol, like a Local Area Network, can be an alternative in the cobalt-60 irradiation plant. The present work suggests, evaluates, qualifies and quantifies this possibility. (author)

  17. Genetics and evolution of hybrid male sterility in house mice.

    Science.gov (United States)

    White, Michael A; Stubbings, Maria; Dumont, Beth L; Payseur, Bret A

    2012-07-01

    Comparative genetic mapping provides insights into the evolution of the reproductive barriers that separate closely related species. This approach has been used to document the accumulation of reproductive incompatibilities over time, but has only been applied to a few taxa. House mice offer a powerful system to reconstruct the evolution of reproductive isolation between multiple subspecies pairs. However, studies of the primary reproductive barrier in house mice-hybrid male sterility-have been restricted to a single subspecies pair: Mus musculus musculus and Mus musculus domesticus. To provide a more complete characterization of reproductive isolation in house mice, we conducted an F(2) intercross between wild-derived inbred strains from Mus musculus castaneus and M. m. domesticus. We identified autosomal and X-linked QTL associated with a range of hybrid male sterility phenotypes, including testis weight, sperm density, and sperm morphology. The pseudoautosomal region (PAR) was strongly associated with hybrid sterility phenotypes when heterozygous. We compared QTL found in this cross with QTL identified in a previous F(2) intercross between M. m. musculus and M. m. domesticus and found three shared autosomal QTL. Most QTL were not shared, demonstrating that the genetic basis of hybrid male sterility largely differs between these closely related subspecies pairs. These results lay the groundwork for identifying genes responsible for the early stages of speciation in house mice.

  18. International Standards for Radiation Sterilization of Medical Devices

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    For a terminally sterilized medical device to be designated '' STERILE '', probability of finding the viable micro-organisms in the device shall be equal to or less than 1 x 10 -6 (EN 556-1:2001: Sterilization of medical devices - Requirements for medical devices to be designated '' STERILE '' - Part 1: Requirements for terminally sterilized medical devices). Author presents the main legal aspects of the international standards for radiation sterilization of medical devices

  19. Mechanisms of urinary tract sterility maintenance

    Directory of Open Access Journals (Sweden)

    Emilia Okrągła

    2014-06-01

    Full Text Available Physiologically, urine and the urinary tract are maintained sterile because of physical and chemical properties of urine and the innate immune system’s action. The urinary tract is constantly exposed to the invasion of microorganisms from the exterior environment, also because of the anatomical placement of the urethra, in the vicinity of the rectum. Particularly vulnerable to urinary tract infections (UTI are women (an additional risk factor is pregnancy, but also the elderly and children. The main pathogens causing UTI are bacteria; in 70-95% of cases it is the bacterium Escherichia coli. Infections caused by viruses and fungi are less common and are associated with decreased immunity, pharmacotherapy, or some diseases. Bacteria have evolved a number of factors that facilitate the colonization of the urinary tract: the cover and cell membrane antigens O and K1, lipopolysaccharide (LPS, fimbriae, pile and cilia. On the other hand, the human organism has evolved mechanisms to hinder colonization of the urinary tract: mechanisms arising from the anatomical structure of the urinary tract, the physicochemical properties of the urine and the activity of the innate immune system, also known as non-specific, which isolates and destroys pathogens using immunological processes, and the mechanisms for release of antimicrobial substances such as Tamm-Horsfall protein, mucopolysaccharides, immunoglobulins IgA and IgG, lactoferrin, lipocalin, neutrophils, cytokines and antimicrobial peptides. This review aims to analyze the state of knowledge on the mechanisms to maintain the sterility of the urinary tract used by the human organism and bacterial virulence factors to facilitate the colonization of the urinary tract.

  20. The efficacy of four gametocides for induction of pollen sterility in ...

    African Journals Online (AJOL)

    Habteab Ghebrehiwot

    2015-02-19

    Feb 19, 2015 ... All the CHAs significantly reduced seed yield, with E4FO, Ethrel and Promalin® at 5000 ... complex and limiting cytoplasmic male sterility systems, increasing crossing ..... (private peasant holdings, meher season). Statistical ...

  1. Genotipagem de polimorfismos associados com sistemas de macho-esterilidade em acessos de cebola adaptados ao Brasil Genotyping of polymorphisms associated with male-sterility systems in onion accessions adapted for cultivation in Brazil

    Directory of Open Access Journals (Sweden)

    Carlos Francisco Ragassi

    2012-09-01

    Full Text Available A produção em escala comercial de sementes híbridas de cebola (Allium cepa tem sido conduzida com o emprego de dois sistemas de macho-esterilidade do tipo genética-citoplasmática (CMS-S e CMS-T em associação ao citoplasma normal (macho-fértil. No entanto, a análise molecular desses diferentes tipos citoplasmáticos ainda não está disponível para um grande número de acessos de cebola adaptados para cultivo em regiões tropicais. Além de adaptação às condições edafoclimáticas do Brasil, muitos desses acessos apresentam tolerância a doenças, sendo de potencial valor como genitores de híbridos. O presente trabalho visou identificar os tipos citoplasmáticos de acessos de cebola de diferentes grupos morfoagronômicos de interesse para o melhoramento genético no Brasil, usando a reação da polimerase em cadeia (PCR com 'primers' específicos para regiões polimórficas do genoma mitocondrial de cebola. Foi observada, nos 66 acessos amostrados, a presença dos três principais tipos de citoplasma descritos para cebola (S, N e T. Foi constatada maior frequência do citoplasma S (56% seguido do citoplasma T (25,8%. Em 18,2% das amostras, foi encontrado exclusivamente o citoplasma N. Essa caracterização pode ser útil para guiar a escolha de materiais genéticos dentro dos programas de melhoramento com objetivo de desenvolver cultivares híbridas adaptadas às condições tropicais.The synthesis of onion (Allium cepa hybrids relies upon the use of two genetic-cytoplasmic male-sterility systems, CMS-S and CMS-T, in association to the normal male-fertile (N cytoplasm. However, the molecular phenotyping of male-sterility-inducing and normal cytoplasms of many onion accessions adapted for cultivation under tropical conditions is not available. Some of these accessions were reported as presenting tolerance to diseases and adaptation to tropical and subtropical regions. Therefore, these accessions are potential sources of parental

  2. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    Science.gov (United States)

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs.

  3. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

    Science.gov (United States)

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter

    2015-01-01

    Objective To compare the safety and efficacy of hysteroscopic sterilization with the “Essure” device with laparoscopic sterilization in a large, all-inclusive, state cohort. Design Population based cohort study. Settings Outpatient interventional setting in New York State. Participants Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Main outcomes measures Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. Results We identified 8048 patients undergoing hysteroscopic sterilization and 44 278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Conclusions Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures

  4. Seeking sterile neutrinos in Finslerian cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Deng [Nankai University, Theoretical Physics Division, Chern Institute of Mathematics, Tianjin (China); Meng, Xin-He [Nankai University, Department of Physics, Tianjin (China)

    2017-11-15

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H{sub 0} tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N{sub eff} = 3.237{sup +0.092}{sub -0.185}, which is consistent with ΔN{sub eff} > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N{sub eff} = 3.143{sup +0.064}{sub -0.066}, which favors ΔN{sub eff} > 0 at the 1.47σ CL, and m{sub ν,sterile}{sup eff} < 0.121 eV at the 2σ CL which is much tighter than the Planck results. This very tight restriction appears to indicate the massive sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration. (orig.)

  5. Genetic basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Robinson, A.S.

    2005-01-01

    The use of the sterile insect technique (SIT) for insect control relies on the introduction of sterility in the females of the wild population. This sterility is produced following the mating of these females with released males carrying, in their sperm, dominant lethal mutations that have been induced by ionizing radiation. The reasons why the SIT can only be effective when the induced sterility in the released males is in the form of dominant lethal mutations, and not some form of sperm inactivation, are discussed, together with the relationship of dominant lethal mutations to dose, sex, developmental stage and the particular species. The combination of genetic sterility with that induced by radiation is also discussed in relation to the use of genetic sexing strains of the Mediterranean fruit fly Ceratitis capitata (Wiedemann) in area-wide integrated pest management (AW-IPM) programmes that integrate the SIT. A case is made to lower the radiation dose used in such programmes so as to produce a more competitive sterile insect. Increased competitiveness can also be achieved by using different radiation environments. As well as radiation-induced sterility, natural mechanisms can be recruited, especially the use of hybrid sterility exemplified by a successful field trial with tsetse flies Glossina spp. in the 1940s. Genetic transformation will make some impact on the SIT, especially regarding the introduction of markers for released flies, and the construction of genetic sexing strains. It is concluded that using a physical process, such as radiation, will always have significant advantages over genetic and other methods of sterilization for the large-scale application of the SIT. (author)

  6. Inheritance of sterility in Dysdercus koenigii F. (Hemiptera: Pyrrhocoridae)

    International Nuclear Information System (INIS)

    Harwalkar, M.R.; Rahalkar, G.W.

    1979-01-01

    It has been suggested that for the control of Lepidopterous populations, release of fully competitive partially sterile males would be more advantageous than the release of completely sterile males. This suggestion is based on the fact, elucidated in many studies, that partially sterilized males mated to normal females produce totally sterile or partially sterile progeny. In Hemiptera too, F 1 progeny of partially sterile males has been shown to inherit sterility. Individual impact of sterility inherited by either sex of the F 1 progeny on population growth has been studied in an hemipteran insect Dysdercus koenigii. A dose of 7 krad induces near-complete sterility in males. When males irradiated with substerilizing doses of 1,2 and 3 krad were crossed with normal females, F 1 progeny of both sexes was partially sterile : the female being more sterile than the males. When the F 1 progeny was intercrossed, there was enhanced reduction in progeny production. (auth.)

  7. Providing Re-Essure-ance to the Nickel-Allergic Patient Considering Hysteroscopic Sterilization.

    Science.gov (United States)

    Lane, Andrew; Tyson, Adam; Thurston, Erin

    2016-01-01

    Essure is a popular method of permanent sterilization that offers a minimally invasive approach that avoids the risks of traditional sterilization procedures in the operating room. Despite the rarity of complications, there has been concern in the popular media over the safety of Essure. We describe the third reported case of systemic contact dermatitis due to the nickel component of the device, with a resolution of symptoms following surgical removal of the inserts. Despite these cases, we believe that extremely rare complications such as this should not dissuade patients from choosing this safe, effective method of sterilization. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  8. Cosmology seeking friendship with sterile neutrinos

    International Nuclear Information System (INIS)

    Hamann, J.; Hannestad, S.; Raffelt, G.G.; Tamborra, I.; Wong, Y.Y.Y.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile neutrino states from the most recent cosmological data. Our results are compatible with the existence of one or perhaps two sterile neutrinos, as suggested by LSND and MiniBooNE, if ms is in the sub-eV range.

  9. Observations on female sterilization in Chile.

    Science.gov (United States)

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical

  10. Spore-Forming Bacteria that Resist Sterilization

    Science.gov (United States)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  11. The pachytene checkpoint and its relationship to evolutionary patterns of polyploidization and hybrid sterility.

    Science.gov (United States)

    Li, X C; Barringer, B C; Barbash, D A

    2009-01-01

    Sterility is a commonly observed phenotype in interspecific hybrids. Sterility may result from chromosomal or genic incompatibilities, and much progress has been made toward understanding the genetic basis of hybrid sterility in various taxa. The underlying mechanisms causing hybrid sterility, however, are less well known. The pachytene checkpoint is a meiotic surveillance system that many organisms use to detect aberrant meiotic products, in order to prevent the production of defective gametes. We suggest that activation of the pachytene checkpoint may be an important mechanism contributing to two types of hybrid sterility. First, the pachytene checkpoint may form the mechanistic basis of some gene-based hybrid sterility phenotypes. Second, the pachytene checkpoint may be an important mechanism that mediates chromosomal-based hybrid sterility phenotypes involving gametes with non-haploid (either non-reduced or aneuploid) chromosome sets. Studies in several species suggest that the strength of the pachytene checkpoint is sexually dimorphic, observations that warrant future investigation into whether such variation may contribute to differences in patterns of sterility between male and female interspecific hybrids. In addition, plants seem to lack the pachytene checkpoint, which correlates with increased production of unreduced gametes and a higher incidence of polyploid species in plants versus animals. Although the pachytene checkpoint occurs in many animals and in fungi, at least some of the genes that execute the pachytene checkpoint are different among organisms. This finding suggests that the penetrance of the pachytene checkpoint, and even its presence or absence can evolve rapidly. The surprising degree of evolutionary flexibility in this meiotic surveillance system may contribute to the observed variation in patterns of hybrid sterility and in rates of polyploidization.

  12. Microscope sterility during spine surgery.

    Science.gov (United States)

    Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J

    2012-04-01

    Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact

  13. Peracetic Acid: A Practical Agent for Sterilizing Heat-Labile Polymeric Tissue-Engineering Scaffolds

    Science.gov (United States)

    Yoganarasimha, Suyog; Trahan, William R.; Best, Al M.; Bowlin, Gary L.; Kitten, Todd O.; Moon, Peter C.

    2014-01-01

    Advanced biomaterials and sophisticated processing technologies aim at fabricating tissue-engineering scaffolds that can predictably interact within a biological environment at the cellular level. Sterilization of such scaffolds is at the core of patient safety and is an important regulatory issue that needs to be addressed before clinical translation. In addition, it is crucial that meticulously engineered micro- and nano- structures are preserved after sterilization. Conventional sterilization methods involving heat, steam, and radiation are not compatible with engineered polymeric systems because of scaffold degradation and loss of architecture. Using electrospun scaffolds made from polycaprolactone, a low melting polymer, and employing spores of Bacillus atrophaeus as biological indicators, we compared ethylene oxide, autoclaving and 80% ethanol to a known chemical sterilant, peracetic acid (PAA), for their ability to sterilize as well as their effects on scaffold properties. PAA diluted in 20% ethanol to 1000 ppm or above sterilized electrospun scaffolds in 15 min at room temperature while maintaining nano-architecture and mechanical properties. Scaffolds treated with PAA at 5000 ppm were rendered hydrophilic, with contact angles reduced to 0°. Therefore, PAA can provide economical, rapid, and effective sterilization of heat-sensitive polymeric electrospun scaffolds that are used in tissue engineering. PMID:24341350

  14. Retrospective cost analysis comparing Essure hysteroscopic sterilization and laparoscopic bilateral tubal coagulation.

    Science.gov (United States)

    Hopkins, Matthew R; Creedon, Douglas J; Wagie, Amy E; Williams, Arthur R; Famuyide, Abimbola O

    2007-01-01

    To compare the institutional cost of permanent female sterilization by Essure hysteroscopic sterilization and laparoscopic bilateral coagulation. Retrospective cohort study (Canadian Task Force classification II-2). Midwestern academic medical center. Women of reproductive age who elected for permanent contraception by the Essure method (n = 43) or by laparoscopic tubal coagulation (n = 44) during the time frame studied. Placement of the Essure inserts according to the manufacturer's instructions or laparoscopic tubal sterilization using bipolar forceps according to standard techniques of open or closed laparoscopy. Cost-center data for the institutional cost of the procedure was abstracted for each patient included in the study. In addition, demographic data and procedural information were obtained and compared for the patient populations. The Essure system of hysteroscopic sterilization had a significantly decreased cost compared with laparoscopic tubal sterilization when both procedures were performed in an operating room setting. The decrease per patient in institutional cost was 180 dollars (p = .038). This included the cost of the confirmatory hysterosalpingogram 3 months after Essure placement and the cost of laparoscopic tubal occlusion by Filshie clip if the Essure micro-inserts could not be placed. The majority of the cost was related to hospital costs as opposed to physician costs. The Essure procedure had higher costs for disposable equipment (p Essure hysteroscopic sterilization had significant cost savings compared with laparoscopic tubal sterilization (p = .038). We believe that our data represent the minimum of potential savings using this approach, and future developments will only increase the cost difference found in our study.

  15. Dissecting the genetic architecture of F1 hybrid sterility in house mice.

    Science.gov (United States)

    Dzur-Gejdosova, Maria; Simecek, Petr; Gregorova, Sona; Bhattacharyya, Tanmoy; Forejt, Jiri

    2012-11-01

    Hybrid sterility as a postzygotic reproductive isolation mechanism has been studied for over 80 years, yet the first identifications of hybrid sterility genes in Drosophila and mouse are quite recent. To study the genetic architecture of F(1) hybrid sterility between young subspecies of house mouse Mus m. domesticus and M. m. musculus, we conducted QTL analysis of a backcross between inbred strains representing these two subspecies and probed the role of individual chromosomes in hybrid sterility using the intersubspecific chromosome substitution strains. We provide direct evidence that the asymmetry in male infertility between reciprocal crosses is conferred by the middle region of M. m. musculus Chr X, thus excluding other potential candidates such as Y, imprinted genes, and mitochondrial DNA. QTL analysis identified strong hybrid sterility loci on Chr 17 and Chr X and predicted a set of interchangeable autosomal loci, a subset of which is sufficient to activate the Dobzhansky-Muller incompatibility of the strong loci. Overall, our results indicate the oligogenic nature of F(1) hybrid sterility, which should be amenable to reconstruction by proper combination of chromosome substitution strains. Such a prefabricated model system should help to uncover the gene networks and molecular mechanisms underlying hybrid sterility. © 2012 The Author(s). Evolution© 2012 The Society for the Study of Evolution.

  16. Male sterility of triticale lines generated through recombination of triticale and rye maintainers

    Directory of Open Access Journals (Sweden)

    Tomasz Warzecha

    2014-11-01

    Full Text Available The Triticum timopheevi cytoplasmic male sterility (cms system in triticale (xTriticosecale Wittmack suffers from a low frequency of maintainers and environmental instability of the male sterility. On the other hand, the Pampa cms system in rye (Secale cereale exhibits strong male sterility and a low frequency of restorers. Here, we report generating hybrids between maintainers of the T. timopheevi cms system in triticale and maintainers of the rye Pampa cms system. Ten hybrids were obtained. Their hybridity was verified by PCR (polymerase chain reaction using ISSR (inter simple sequence repeats primers. The cms maintaining ability of F2 individuals and their progeny was tested. The F2 plants were crossed to male sterile lines of triticale carrying the T. timopheevi cytoplasm. Among 180 G1 offspring of these crosses, 71 (39.4% were completely male sterile. Fourteen F2 individuals (7.8%, as well as their F2S1 and progeny, generated stable male sterility in G1, G1BC1 and G1BC2 generations after the crosses. Our results suggest that it is possible to produce a more stable cms system in triticale based on the T. timopheevi cytoplasm as compared to the existing one.

  17. Sterilization of health care products - Radiation. Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2006-01-01

    A sterile medical device is one that is free of viable microorganisms. International Standards, which specify requirements for validation and routine control of sterilization processes, require, when it is necessary to supply a sterile medical device, that adventitious microbiological contamination of a medical device prior to sterilization be minimized. Even so, medical devices produced under standard manufacturing conditions in accordance with the requirements for quality management systems (see, for example, ISO 13485) may, prior to sterilization, have microorganisms on them, albeit in low numbers. Such medical devices are non-sterile. The purpose of sterilization is to inactivate the microbiological contaminants and thereby transform the nonsterile medical devices into sterile ones. The kinetics of inactivation of a pure culture of microorganisms by physical and/or chemical agents used to sterilize medical devices can generally best be described by an exponential relationship between the numbers of microorganisms surviving and the extent of treatment with the sterilizing agent; inevitably this means that there is always a finite probability that a microorganism may survive regardless of the extent of treatment applied. For a given treatment, the probability of survival is determined by the number and resistance of microorganisms and by the environment in which the organisms exist during treatment. It follows that the sterility of any one medical device in a population subjected to sterilization processing cannot be guaranteed and the sterility of a processed population is defined in terms of the probability of there being a viable microorganism present on a medical device. This part of ISO 11137 describes requirements that, if met, will provide a radiation sterilization process intended to sterilize medical devices, that has appropriate microbicidal activity. Furthermore, compliance with the requirements ensures that this activity is both reliable and

  18. Gamma-ray irradiation, autoclave and ethylene oxide sterilization to thermosetting polyurethane: sterilization to polyurethane

    International Nuclear Information System (INIS)

    Hirata, Noriko; Matsumoto, Ken-Ichi; Inishita, Takashi; Takenaka, Yoshinori; Suma, Yasunori; Shintani, Hideharu; National Inst. of Health Sciences, Tokyo

    1995-01-01

    Thermosetting polyurethane (PU) is widely used in a large variety of medical devices. 4,4'-methylenedianiline (MDA) was produced from PU by sterilization and it was studied for the relationship between urethane components or polymer characteristics and formation of MDA upon sterilization, using the commercially available dialyzers fabricated with different combination of isocyanate and polyol. We confirmed that the molecular-weight of polyol influenced the production of MDA upon sterilization. (author)

  19. A review: radiation sterilization of pharmaceuticals

    International Nuclear Information System (INIS)

    Jacobs, G.P.

    1985-01-01

    The literature on the effects of γ-radiation on drugs, relevant to their sterilization or decontamination, is reviewed. This literature survey essentially covers the past 7 yr, although relevant reports not covered in previous reviews have been included. (author)

  20. Radiation sterilization of animal farm sewage

    International Nuclear Information System (INIS)

    Rosiak, J.; Perkowski, J.; Pekala, W.

    1984-01-01

    Influence of irradiation on organisms appearing in farm sewage has been discussed. Practical examples of employing the radiation to sterilization of municipal wastes and liquid sewage from the industrial swine farms have been presented. (author)

  1. Determination of sterilizing dose of lincocine drug

    International Nuclear Information System (INIS)

    Adawi, M.A.; Shamma, M.; Al-Mousa, A.

    1998-01-01

    There are too many antibiotics that have been studied on their dry solid state to determine their safe sterilizing dose by decreasing their bio burden in order to reach the sterility assurance level (SAL) needed. The sterilizing radiating dose of lincocine was determined according to information about their bio burden and radiating sensitivity at the sterility assurance level 10-6. The study of bio burden has shown that the contamination was fungal (Pemicillium sp.) and by applying the same tests to the raw materials of lincocine it came out that the cause of contamination was bad storage and that the radiating dose required to decrease the bio burden was 5.5 kGy. (author)

  2. Searching for Sterile Neutrinos with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Timmons, Ashley [Manchester U.

    2016-01-01

    This document presents the latest results for a 3+1 sterile neutrino search using the $10.56 \\times 10^{20}$ protons-on-target data set taken from 2005 - 2012. By searching for oscillations driven by a large mass splitting, MINOS is sensitive to the existence of sterile neutrinos through any energy dependent deviations using a charged current sample, as well as looking at any relative deficit between neutral current events between the far and near detectors. This document will discuss the novel analysis that enabled a search for sterile neutrinos setting a limit in the previously unexplored regions in the parameter space $\\{\\Delta m^{2}_{41}, \\sin^2\\theta_{24}\\}$. The results presented can be compared to the parameter space suggested by LSND and MiniBooNE and complements other previous experimental searches for sterile neutrinos in the electron neutrino appearance channel.

  3. Methods of sterilization and monitoring of sterilization across selected dental practices in karachi, pakistan

    International Nuclear Information System (INIS)

    Ahmed, H.

    2015-01-01

    To assess methods of sterilization in dental practices in Karachi and secondly to investigate methods of monitoring sterilization in dental practices in Karachi, Pakistan. Study Design: Cross-sectional, descriptive study. Place and Duration of Study: Dental colleges, hospitals and private clinics of Karachi, Pakistan, from January to March 2013. Methodology: A total of 251 questionnaires were obtained. Descriptive statistics were computed and differences between groups were assessed through chi-square test using Statistical Package for the Social Sciences (SPSS) version 16.0. P-value < 0.05 was taken as statistically significant. Results: Autoclave, used by 155 (61.8%) dentists was the most common method of sterilization followed by more than one method, 65 (25.9%); dry heat, 24 (9.6%); and cold sterilization, 7 (2.8%). Majority of dentists, 126 (50.1%), never monitored sterilization and those who did monitored mostly monthly. Statistically significant difference was found amongst the three groups of dentists monitoring sterilization (p=0.09) and methods of sterilization (p < 0.01). Conclusion: Statistically significant difference was found in infection control practices of specialists, postgraduate trainees and general dentists regarding method of monitoring sterilization with majority of dentists never monitoring sterilization. (author)

  4. 21 CFR 522.1862 - Sterile pralidoxime chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile pralidoxime chloride. 522.1862 Section 522....1862 Sterile pralidoxime chloride. (a) Chemical name. 2-Formyl-1-methylpyridinium chloride oxime. (b) Specifications. Sterile pralidoxime chloride is packaged in vials. Each vial contains 1 gram of sterile...

  5. Sterilization of instruments in solar ovens

    Energy Technology Data Exchange (ETDEWEB)

    Fjendbo Joergensen, A. [Odense Univ. Hospital, Dept. of Infectious Diseases, Odense (Denmark); Noehr, K. [Odense Technical College, Dept. of Metal, Odense (Denmark); Boisen, F. [The Danish Veterinary and Food Administration Funen, Dept. of Microbiology, Odense (Denmark)

    2000-07-01

    The sterilization of instruments in rural health clinics in less developed countries is an increasing problem because chemical methods can no longer be recommended and wood fuel is becoming more and more scarce. Thus, it seemed obvious to try to utilize solar energy for sterilization purposes. A solar oven was designed and manufactured using local materials and simple tools. The solar oven was tested by physical, chemical, and microbiological methods. A mathematical model for the sterilization effect was developed and programmed into a microprocessor that was connected to a thermocouple. The microprocessor switches on a green light when the sterilization is completed. After successful testing, the oven was built into the west-facing wall of a rural health clinic and used daily for sterilization. The oven was able to generate temperatures above 180 deg. C. On all days with direct sunlight the oven fulfilled the international recommendations for hot air sterilization because no growth could be detected from any of the test bacteria spores. The chemical indicators Brownes tubes types 3 and 5 also changed colours. The solar oven was easy to use for the clinic staff, but during the seasons with low sun position (in Tanzania, December and June) it was difficult to achieve a high enough temperature for sterilization. Therefore, if the method is to be used throughout the year the oven must be moved to collect the sun's rays from several directions, or the clinic must have more than one solar oven facing in different directions. We conclude that the solar oven is a realistic method for sterilization of instruments. (au)

  6. Radiation sterilization of potato starch and Sedonik

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Ismatov, N.B.; Saidov, R.P. et al.

    2016-01-01

    The raw material of pharmaceutical preparations potato starch and sedative means of Sedonik are sterilized at the electron's accelerator Electronics U-003. It is established that at 20.3 kGy absorbed dose and electron's energy 3 - 5 MeV the results of microbiological analysis showed sterility of potato starch and Sedonik and correspondence of their physical-optical properties to the requirements of normative documents. (authors)

  7. Impact of ethylene oxide gas sterilization of duodenoscopes after a carbapenem-resistant Enterobacteriaceae outbreak.

    Science.gov (United States)

    Naryzhny, Igor; Silas, Dean; Chi, Kenneth

    2016-08-01

    Carbapenem-resistant Enterobacteriaceae (CRE) outbreaks have been implicated at several medical institutions involving gastroenterology laboratories and, specifically, duodenoscopes. Currently, there are no specific guidelines to eradicate or prevent the outbreak of this bacteria. We describe ethylene oxide (ETO) gas sterilizations of duodenoscopes to address this issue. A complete investigation of the gastroenterology laboratory and an evaluation by the Centers for Disease Control and Prevention concluded that no lapses were found in the reprocessing of the equipment. With no deficiencies to address, we began a novel cleaning process using surgical ETO gas sterilizers in addition to standard endoscope reprocessing recommendations and guidelines, all while trying to eradicate the CRE contamination and prevent future recurrences. We also instituted a surveillance system for recurrence of CRE contamination via monthly cultures of the duodenoscopes. Between October 2013 and April 2014, 589 ERCPs were performed with 645 ETO gas sterilizations of 6 duodenoscopes. Given the extra 16 hours needed to sterilize the duodenoscopes, our institution incurred costs resulting from purchasing additional equipment and surveillance cultures. Four duodenoscopes sustained damage during this period; however, this could not be directly attributed to the sterilization process. Furthermore, after an 18-month success period we encountered a positive CRE culture after sterilization, albeit of a different strain than originally detected during the outbreak. The duodenoscope underwent additional ETO gas sterilization, with a negative repeated culture; all potentially exposed individuals screened negative for CRE. Proper use of high-level disinfection alone may not eliminate multidrug-resistant organisms from duodenoscopes. In this single-center study, the addition of ETO sterilization and frequent monitoring with cultures reduced duodenoscope contamination and eliminated clinical infections

  8. Comparison of steam sterilization conditions efficiency in the treatment of Infectious Health Care Waste.

    Science.gov (United States)

    Maamari, Olivia; Mouaffak, Lara; Kamel, Ramza; Brandam, Cedric; Lteif, Roger; Salameh, Dominique

    2016-03-01

    Many studies show that the treatment of Infectious Health Care Waste (IHCW) in steam sterilization devices at usual operating standards does not allow for proper treatment of Infectious Health Care Waste (IHCW). Including a grinding component before sterilization allows better waste sterilization, but any hard metal object in the waste can damage the shredder. The first objective of the study is to verify that efficient IHCW treatment can occur at standard operating parameters defined by the contact time-temperature couple in steam treatment systems without a pre-mixing/fragmenting or pre-shredding step. The second objective is to establish scientifically whether the standard operation conditions for a steam treatment system including a step of pre-mixing/fragmenting were sufficient to destroy the bacterial spores in IHCW known to be the most difficult to treat. Results show that for efficient sterilization of dialysis cartridges in a pilot 60L steam treatment system, the process would require more than 20 min at 144°C without a pre-mixing/fragmenting step. In a 720L steam treatment system including pre-mixing/fragmenting paddles, only 10 min at 144°C are required to sterilize IHCW proved to be sterilization challenges such as dialysis cartridges and diapers in normal conditions of rolling. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Application of radiation sterilization to bone allografts

    International Nuclear Information System (INIS)

    Li Youchen; Li Baoxing; Sun Shiquan

    2003-01-01

    With prominent features of high penetration, no temperature increases, no harm residues and easy dose control, radiation sterilization technology is widely used in the sterilization of bone allografts. During the radiation sterilization of bone allografts, the irradiation dose should be optimized to ensure sterilization of grafts and preservation of biological properties of bone. The immunogenicity of allografts is decreased by irradiation. IAEA devoted great efforts to generalization of the radiation sterilization of tissue allografts in developing countries since 1986. Tissue Bank of China Institute for Radiation Protection (CIRP) was initially established in 1988 with the support of IAEA, afterwards restructured into Shanxi Provincial Tissue Bank (SPTB). The SPTB, as the first manufacturer of the irradiated bone allografts in the country, was granted production license by the State Food and Drug Administration of China. The SPTB sponsored IAEA/RCA Training Courses, National Symposium on Bone Grafting, and National Training Course on Bone Banking. Technique of radiation sterilization for bone grafts has become popularized in China after these activities. (authors)

  10. Production of a sterile species: Quantum kinetics

    Science.gov (United States)

    Boyanovsky, D.; Ho, C. M.

    2007-10-01

    Production of a sterile species is studied within an effective model of active-sterile neutrino mixing in a medium in thermal equilibrium. The quantum kinetic equations for the distribution functions and coherences are obtained from two independent methods: the effective action and the quantum master equation. The decoherence time scale for active-sterile oscillations is τdec=2/Γaa, but the evolution of the distribution functions is determined by the two different time scales associated with the damping rates of the quasiparticle modes in the medium: Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where Γaa is the interaction rate of the active species in the absence of mixing and θm the mixing angle in the medium. These two time scales are widely different away from Mikheyev-Smirnov-Wolfenstein resonances and preclude the kinetic description of active-sterile production in terms of a simple rate equation. We give the complete set of quantum kinetic equations for the active and sterile populations and coherences and discuss in detail the various approximations. A generalization of the active-sterile transition probability in a medium is provided via the quantum master equation. We derive explicitly the usual quantum kinetic equations in terms of the “polarization vector” and show their equivalence to those obtained from the quantum master equation and effective action.

  11. Voluntary sterilization in Serbia: Unmet need?

    Directory of Open Access Journals (Sweden)

    Rašević Mirjana M.

    2002-01-01

    Full Text Available Is voluntary sterilization as a birth control method accepted in Serbia? This is certainly a question that is being imposed for research, regardless of the fact that voluntary sterilization is neither accessible nor promoted. Most importantly because there is no understanding in the social nor political sphere for legalization of voluntary sterilization as a form of birth control, apart from the clear necessity for this, first, step. They are: the recognition that voluntary sterilization is an efficient and safe birth control method, respectability of basic human as well as sexual and reproductive rights, spreading of sterilization as a form of birth control among population of both developed and developing countries and an epidemic diffusion of repeated induced abortions in Serbia. Thus individual recognition of the advantages of relying on voluntary sterilization, in a non-encouraging atmosphere, certainly represents one more argument to enable couples to prevent conception by sterilization. Since it was impossible to carry out a representative research among the population of men and women who are at risk for conception, an attempt was made to obtain a reply to the set question among women who decided to induce abortion. It was done out of at least two reasons. The first being that women with induced abortion in their reproductive history were the target group for voluntary sterilization. The second reason was based on the assumption that bringing a decision on induced abortion is preceded by the reconsideration of an earlier adopted strategy regarding children, giving birth and contraception and thus its rational component is revealed more and therefore more easily measurable. The research was carried out in the University Clinic of Obstetrics and Gynecology 'Narodni front' in Belgrade from January 21st o March 1st 2002, and included 296 women. By comparing the social and demographic characteristics of the female respondents, as well as

  12. [Juvenile sterile granulomatous dermatitis and lymphadenitis in the dog].

    Science.gov (United States)

    Weingart, C; Eule, C; Welle, M; Kohn, B

    2011-04-01

    Juvenile sterile granulomatous dermatitis and lymphadenitis is a rare immune-mediated skin disease in young dogs. History, signalment, diagnostics, treatment, and outcome in 10 dogs are described. The age ranged from 8 - 36 weeks. The lymph nodes were enlarged in all dogs, especially the mandibular and prescapular lymph nodes. Systemic signs including fever were present in 8 dogs. Seven dogs suffered from blepharitis and painful edema of the muzzle with hemorrhagic discharge, pustules and papules. Cytology of pustules and lymph node aspirates revealed a pyogranulomatous inflammation. In 7 cases the diagnosis of juvenile sterile granulomatous dermatitis and lymphadenitis was confirmed by histology. Nine dogs were treated with prednisolone (0.5 - 1.25 mg/kg BID), H2-receptor antagonists and analgetics; all dogs were treated with antibiotics. Four dogs were treated with eye ointment containing antibiotics and glucocorticoids. The prednisolone dosage was tapered over 3 - 8 weeks. One dog had a relapse.

  13. The Sterile Insect Technique:Current and Future Prospects

    International Nuclear Information System (INIS)

    ALRubeai, H.F.

    2004-01-01

    Considering the importance of the Key insect pests and their potential for economic and environmental impact, such species are the targets for area-wide approaches including in some cases the use of SIT. At the heart of the SIT is genetic sterility that is introduced into the target population by releasing large numbers of sterile insects . The development of an SIT package for a Key pest, involving mass rearing and aerial dispersion, as well as field monitoring and a suppression system. Losses caused by insect pests throughout the developing world will continue to be unacceptably high in the foreseeable future. Therefore, the economic feasibility of non-chemical pest control tools, including biologically -based methods such as SIT, will become increasingly apparent . This study include an overview of the basic scientific principles of SIT , is successful applications and related mass rearing and irradiation facilities over the world. (author)

  14. Hybrid male sterility is caused by mitochondrial DNA deletion.

    Science.gov (United States)

    Hayashida, Kenji; Kohno, Shigeru

    2009-07-01

    Although it is known that the hybrid male mouse is sterile just like any other animal's heterogametic sex, the reason why only the male germ cells are impaired has yet to be discovered. TdT-mediated dUTP nick end labeling assay using a confocal fluorescence microscope and DNA fragmentation assay of hybrid testis indicated destruction of the mitochondrial DNA (mtDNA) rather than the nuclear DNA. Previously we reported that maternal mtDNA inheritance is through selective sperm mtDNA elimination based on the sperm factor and two egg factors, and expression of these three factors was recognized in the hybrid testis. It was thereby assumed that mtDNA destruction caused by the expression of maternal mtDNA inheritance system in male germ cells is implicated in the hybrid male sterility of mice.

  15. Biological wound dressings sterilized with gamma radiation: Mexican clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Pardo, M.E. [Instituto Nacional de Investigaciones Nucleares, Apdo. postal 18-1027, Col. Escandon 11801 Mexico DF (Mexico)], E-mail: memp@nuclear.inin.mx; Ley-Chavez, E. [ISSEMYM Toluca, Mexico DF (Mexico); Reyes-Frias, M.L. [Instituto Nacional de Investigaciones Nucleares, Apdo. postal 18-1027, Col. Escandon 11801 Mexico DF (Mexico); Rodriguez-Ferreyra, P. [Hospital ' Dr. Nicolas San Juan' , Toluca, Mexico DF (Mexico); Vazquez-Maya, L.; Salazar, M.A. [Hospital General de Mexico, Mexico DF (Mexico)

    2007-11-15

    Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is 'Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation'. At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with children and adult patients who underwent medical treatment with radiosterilized amnion and pig skin, used as biological wound dressings on burns and ocular surface disorders.

  16. Biological wound dressings sterilized with gamma radiation: Mexican clinical experience

    Science.gov (United States)

    Martínez-Pardo, M. E.; Ley-Chávez, E.; Reyes-Frías, M. L.; Rodríguez-Ferreyra, P.; Vázquez-Maya, L.; Salazar, M. A.

    2007-11-01

    Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is "Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation". At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with children and adult patients who underwent medical treatment with radiosterilized amnion and pig skin, used as biological wound dressings on burns and ocular surface disorders.

  17. Genetic technologies to enhance the Sterile Insect Technique (SIT)

    International Nuclear Information System (INIS)

    Alphey, Luke; Baker, Pam; Condon, George C.; Condon, Kirsty C.; Dafa'alla, Tarig H.; Fu, Guoliang; Jin, Li; Labbe, Genevieve; Morrison, Neil M.; Nimmo, Derric D.; O'Connell, Sinead; Phillips, Caroline E.; Plackett, Andrew; Scaife, Sarah; Woods, Alexander; Burton, Rosemary S.; Epton, Matthew J.; Gong, Peng

    2006-01-01

    The Sterile Insect Technique (SIT) has been used very successfully against range of pest insects, including various tephritid fruit flies, several moths and a small number of livestock pests. However, modern genetics could potentially provide several improvements that would increase the cost-effectiveness of SIT, and extend the range of suitable species. These include improved identification of released individuals by incorporation of a stable, heritable, genetic marker; built-in sex separation (genetic sexing); reduction of the hazard posed by non-irradiated accidental releases from mass-rearing facility (fail-safe); elimination of the need for sterilization by irradiation (genetic sterilization). We discuss applications of these methods and the state of the art, at the time of this meeting, in developing suitable strains. We have demonstrated, in several key pest species, that the required strains can be constructed by introducing a repressible dominant lethal genetic system, a method known as RIDL(trade mark). Based on field experience with Medfly, incorporation of a genetic sexing system into SIT programs for other tephritids could potentially provide a very significant improvement in cost-effectiveness. We have now been able to make efficient female-lethal strains for Medfly. One advantage of our approach is that it should be possible rapidly to extend this technology to other fruit fly species; indeed we have recently been able also to make genetic sexing strains of Medfly (Anastrepha ludens). (author)

  18. Genetic technologies to enhance the Sterile Insect Technique (SIT)

    Energy Technology Data Exchange (ETDEWEB)

    Alphey, Luke; Baker, Pam; Condon, George C; Condon, Kirsty C; Dafa' alla, Tarig H; Fu, Guoliang; Jin, Li; Labbe, Genevieve; Morrison, Neil M; Nimmo, Derric D; O' Connell, Sinead; Phillips, Caroline E; Plackett, Andrew; Scaife, Sarah; Woods, Alexander [Oxitec Ltd., Oxford (United Kingdom); Burton, Rosemary S; Epton, Matthew J; Gong, Peng [University of Oxford (United Kingdom). Dept. of Zoology

    2006-07-01

    The Sterile Insect Technique (SIT) has been used very successfully against range of pest insects, including various tephritid fruit flies, several moths and a small number of livestock pests. However, modern genetics could potentially provide several improvements that would increase the cost-effectiveness of SIT, and extend the range of suitable species. These include improved identification of released individuals by incorporation of a stable, heritable, genetic marker; built-in sex separation (genetic sexing); reduction of the hazard posed by non-irradiated accidental releases from mass-rearing facility (fail-safe); elimination of the need for sterilization by irradiation (genetic sterilization). We discuss applications of these methods and the state of the art, at the time of this meeting, in developing suitable strains. We have demonstrated, in several key pest species, that the required strains can be constructed by introducing a repressible dominant lethal genetic system, a method known as RIDL(trade mark). Based on field experience with Medfly, incorporation of a genetic sexing system into SIT programs for other tephritids could potentially provide a very significant improvement in cost-effectiveness. We have now been able to make efficient female-lethal strains for Medfly. One advantage of our approach is that it should be possible rapidly to extend this technology to other fruit fly species; indeed we have recently been able also to make genetic sexing strains of Medfly (Anastrepha ludens). (author)

  19. Biological wound dressings sterilized with gamma radiation: Mexican clinical experience

    International Nuclear Information System (INIS)

    Martinez-Pardo, M.E.; Ley-Chavez, E.; Reyes-Frias, M.L.; Rodriguez-Ferreyra, P.; Vazquez-Maya, L.; Salazar, M.A.

    2007-01-01

    Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is 'Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation'. At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with children and adult patients who underwent medical treatment with radiosterilized amnion and pig skin, used as biological wound dressings on burns and ocular surface disorders

  20. Cytoplasmic male sterility (CMS) in hybrid breeding in field crops.

    Science.gov (United States)

    Bohra, Abhishek; Jha, Uday C; Adhimoolam, Premkumar; Bisht, Deepak; Singh, Narendra P

    2016-05-01

    A comprehensive understanding of CMS/Rf system enabled by modern omics tools and technologies considerably improves our ability to harness hybrid technology for enhancing the productivity of field crops. Harnessing hybrid vigor or heterosis is a promising approach to tackle the current challenge of sustaining enhanced yield gains of field crops. In the context, cytoplasmic male sterility (CMS) owing to its heritable nature to manifest non-functional male gametophyte remains a cost-effective system to promote efficient hybrid seed production. The phenomenon of CMS stems from a complex interplay between maternally-inherited (mitochondrion) and bi-parental (nucleus) genomic elements. In recent years, attempts aimed to comprehend the sterility-inducing factors (orfs) and corresponding fertility determinants (Rf) in plants have greatly increased our access to candidate genomic segments and the cloned genes. To this end, novel insights obtained by applying state-of-the-art omics platforms have substantially enriched our understanding of cytoplasmic-nuclear communication. Concomitantly, molecular tools including DNA markers have been implicated in crop hybrid breeding in order to greatly expedite the progress. Here, we review the status of diverse sterility-inducing cytoplasms and associated Rf factors reported across different field crops along with exploring opportunities for integrating modern omics tools with CMS-based hybrid breeding.

  1. Steam sterilization and automatic dispensing of [{sup 18}F]fludeoxyglucose (FDG) for injection

    Energy Technology Data Exchange (ETDEWEB)

    Karwath, Pascal [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany); Sartor, Johannes [MC-Pharma GmbH (MCP), Bonn (Germany); Gries, Wolfgang [MC-Pharma GmbH (MCP), Bonn (Germany); Wodarski, Christine [MC-Pharma GmbH (MCP), Bonn (Germany); Dittmar, Claus [MC-Pharma GmbH (MCP), Bonn (Germany); Biersack, Hans J [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Guhlke, Stefan [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany)

    2005-04-01

    For the purpose of implementing steam sterilization of 2-[{sup 18}F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity ({approx}99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories.

  2. Steam sterilization and automatic dispensing of [18F]fludeoxyglucose (FDG) for injection

    International Nuclear Information System (INIS)

    Karwath, Pascal; Sartor, Johannes; Gries, Wolfgang; Wodarski, Christine; Dittmar, Claus; Biersack, Hans J.; Guhlke, Stefan

    2005-01-01

    For the purpose of implementing steam sterilization of 2-[ 18 F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity (∼99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories

  3. Early events in speciation: polymorphism for hybrid male sterility in Drosophila.

    Science.gov (United States)

    Reed, Laura K; Markow, Therese A

    2004-06-15

    Capturing the process of speciation early enough to determine the initial genetic causes of reproductive isolation remains a major challenge in evolutionary biology. We have found, to our knowledge, the first example of substantial intraspecific polymorphism for genetic factors contributing to hybrid male sterility. Specifically, we show that the occurrence of hybrid male sterility in crosses between Drosophila mojavensis and its sister species, Drosophila arizonae, is controlled by factors present at different frequencies in different populations of D. mojavensis. In addition, we show that hybrid male sterility is a complex phenotype; some hybrid males with motile sperm still cannot sire offspring. Because male sterility factors in hybrids between these species are not yet fixed within D. mojavensis, this system provides an invaluable opportunity to characterize the genetics of reproductive isolation at an early stage.

  4. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice

    NARCIS (Netherlands)

    El-Namaky, R.; Oort, van P.A.J.

    2017-01-01

    Background: There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two

  5. Application of Quality by Design (QbD) Principles to Extractables/Leachables Assessment. Establishing a Design Space for Terminally Sterilized Aqueous Drug Products Stored in a Plastic Packaging System.

    Science.gov (United States)

    Jenke, Dennis

    2010-01-01

    The concept of quality by design (QbD) reflects the current global regulatory thinking related to pharmaceutical products. A cornerstone of the QbD paradigm is the concept of a design space, where the design space is a multidimensional combination of input variables and process parameters that have been demonstrated to provide the assurance of product quality. If a design space can be established for a pharmaceutical process or product, then operation within the design space confirms that the product or process output possesses the required quality attributes. This concept of design space can be applied to the safety (leachables) assessment of drug products manufactured and stored in packaging systems. Critical variables in such a design space would include those variables that affect the interaction of the drug product and its packaging, including (a) composition of the drug product, (b) composition of the packaging system, (c) configuration of the packaging system, and (d) the conditions of contact. This paper proposes and justifies such a leachables design space for aqueous drug products packaged in a specific plastic packaging system. Such a design space has the following boundaries:Aqueous drug products with a pH in the range of 2 to 8 and that contain no polarity-impacting agents such as organic solubilizers and stabilizers (addressing variable a). Packaging systems manufactured from materials that meet the system's existing material specifications (addressing variable b). Nominal fill volumes from 50 to 1000 mL (addressing variable c). Products subjected to terminal sterilization and then stored at room temperature for a period of up to 24 months (addressing variable d). The ramification of such a design space is that any drug product that falls within these boundaries is deemed to be compatible with the packaging system, from the perspective of safety, without the requirement of supporting drug product testing. When drug products are packaged in plastic

  6. Homestake result, sterile neutrinos, and low energy solar neutrino experiments

    Science.gov (United States)

    de Holanda, P. C.; Smirnov, A. Yu.

    2004-06-01

    The Homestake result is about ˜2σ lower than the Ar-production rate, QAr, predicted by the large mixing angle (LMA) Mikheyev-Smirnov-Wolfenstein solution of the solar neutrino problem. Also there is no apparent upturn of the energy spectrum (R≡Nobs/NSSM) at low energies in SNO and Super-Kamiokande. Both these facts can be explained if a light, Δm201˜(0.2 2)×10-5 eV2, sterile neutrino exists which mixes very weakly with active neutrinos: sin2 2α˜(10-5 10-3). We perform both the analytical and numerical study of the conversion effects in the system of two active neutrinos with the LMA parameters and one weakly mixed sterile neutrino. The presence of sterile neutrino leads to a dip in the survival probability in the intermediate energy range E=(0.5 5) MeV thus suppressing the Be, or/and pep, CNO, as well as B electron neutrino fluxes. Apart from diminishing QAr it leads to decrease of the Ge-production rate and may lead to the decrease of the BOREXINO signal as well as the CC/NC ratio at SNO. Future studies of the solar neutrinos by SNO, SK, BOREXINO, and KamLAND as well as by the new low energy experiments will allow us to check this possibility.

  7. Atmospheric-pressure plasma decontamination/sterilization chamber

    Science.gov (United States)

    Herrmann, Hans W.; Selwyn, Gary S.

    2001-01-01

    An atmospheric-pressure plasma decontamination/sterilization chamber is described. The apparatus is useful for decontaminating sensitive equipment and materials, such as electronics, optics and national treasures, which have been contaminated with chemical and/or biological warfare agents, such as anthrax, mustard blistering agent, VX nerve gas, and the like. There is currently no acceptable procedure for decontaminating such equipment. The apparatus may also be used for sterilization in the medical and food industries. Items to be decontaminated or sterilized are supported inside the chamber. Reactive gases containing atomic and metastable oxygen species are generated by an atmospheric-pressure plasma discharge in a He/O.sub.2 mixture and directed into the region of these items resulting in chemical reaction between the reactive species and organic substances. This reaction typically kills and/or neutralizes the contamination without damaging most equipment and materials. The plasma gases are recirculated through a closed-loop system to minimize the loss of helium and the possibility of escape of aerosolized harmful substances.

  8. Gamma radiation sterilized amnion: use in ophthalmology

    International Nuclear Information System (INIS)

    Martinez P, M. E.; Leon T, Y.; Vazquez M, L.

    2010-10-01

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with 60 Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  9. Gamma radiation sterilized amnion: use in ophthalmology

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Leon T, Y. [Hospital General Regional 220, IMSS, Paseo Tollocan No. 620, Col. Vertice, Toluca 50150, Estado de Mexico (Mexico); Vazquez M, L., E-mail: esther.martinez@inin.gob.m [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06720 Mexico D. F. (Mexico)

    2010-10-15

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with {sup 60}Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  10. Sterilization and disinfection: the prevailing indifference

    International Nuclear Information System (INIS)

    Mirza, I.

    2007-01-01

    To evaluate the knowledge and attitude of health care professionals towards the process of sterilization and disinfection, and to check the adequacy of the reading material accessible to them. The study comprised of three components. In the first part, sections devoted to this subject in the popular books read by the students of operation theatre assistant course and students of diploma in general nursing were examined for adequacy and authenticity of information. In the second part, standard operating procedures were examined regarding sterilization of textile, rubber tubes of suction units and diathermy hand pieces of 20 operation theatres of three teaching hospital attached to undergraduate medical college of Punjab. In the third part of the study, working knowledge of 64 practicing operation theatre assistants and 57 practicing nurses was assessed through a questionnaire. It was found that popular books either did not contain the required information or the information provided was misleading or incorrect. Standard operating procedures for sterilization of selected items of all the operation theatres studied fell much below the standard of practice desired in the light of current knowledge and contemporary practices. Finally the working knowledge of the professionals studied was much below the bare minimum expected by the profession. There is a dire need for upgrading the knowledge and attitude of health care professionals regarding sterilization, besides improving the operation theatres sterilization procedures. (author)

  11. Revisiting cosmological bounds on sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, Aaron C. [Institute for Particle Physics Phenomenology (IPPP), Department of Physics, Durham University, Durham DH1 3LE (United Kingdom); Martínez, Enrique Fernández [Departamento and Instituto de Física Teórica (IFT), UAM/CSIC, Universidad Autonoma de Madrid, C/ Nicolás Cabrera 13-15, E-28049 Cantoblanco, Madrid (Spain); Hernández, Pilar; Mena, Olga [Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Lattanzi, Massimiliano, E-mail: aaron.vincent@durham.ac.uk, E-mail: enrique.fernandez-martinez@uam.es, E-mail: m.pilar.hernandez@uv.es, E-mail: omena@ific.uv.es, E-mail: lattanzi@fe.infn.it [Dipartimento di Fisica e Science della Terra, Università di Ferrara and INFN, sezione di Ferrara, Polo Scientifico e Tecnologico, Edificio C Via Saragat, 1, I-44122 Ferrara (Italy)

    2015-04-01

    We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expected in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.

  12. Ionizing radiation for sterilization of medical products and biological tissues

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S K; Raghevendrarao, M K [Bhabha Atomic Research Centre, Bombay (India). Library and Technical Information Section

    1975-10-01

    The article reviews the deliberations of the International Symposium on Ionizing Radiation for Sterilization of Medical Products and Biological Tissues which was held during 9-13 December 1974 under the auspices of the IAEA at the Bhabha Atomic Research Centre, Bombay. 42 papers were presented in the following broad subject areas: (1) Microbiological Control aspects of radiation sterilization, (2) Dosimetry aspects of radiation sterilization practices, (3) Effects of sterilizing radiation dose on the constituents of medical products, (4) Application of radiation sterilization of medical products of biological origin, (5) Technological aspects of radiation sterilization facilities, (6) Radiation sterilization of pharmaceutical substances, (7) Reports on current status of radiation sterilization of medical products in IAEA member states and (8) Working group discussion on the revision of the IAEA recommended code of practice for radiation sterilization of medical products.

  13. Comparative transcript profiling of the fertile and sterile flower buds of pol CMS in B. napus.

    Science.gov (United States)

    An, Hong; Yang, Zonghui; Yi, Bin; Wen, Jing; Shen, Jinxiong; Tu, Jinxing; Ma, Chaozhi; Fu, Tingdong

    2014-04-03

    The Polima (pol) system of cytoplasmic male sterility (CMS) and its fertility restoration gene Rfp have been used in hybrid breeding in Brassica napus, which has greatly improved the yield of rapeseed. However, the mechanism of the male sterility transition in pol CMS remains to be determined. To investigate the transcriptome during the male sterility transition in pol CMS, a near-isogenic line (NIL) of pol CMS was constructed. The phenotypic features and sterility stage were confirmed by anatomical analysis. Subsequently, we compared the genomic expression profiles of fertile and sterile young flower buds by RNA-Seq. A total of 105,481,136 sequences were successfully obtained. These reads were assembled into 112,770 unigenes, which composed the transcriptome of the bud. Among these unigenes, 72,408 (64.21%) were annotated using public protein databases and classified into functional clusters. In addition, we investigated the changes in expression of the fertile and sterile buds; the RNA-seq data showed 1,148 unigenes had significantly different expression and they were mainly distributed in metabolic and protein synthesis pathways. Additionally, some unigenes controlling anther development were dramatically down-regulated in sterile buds. These results suggested that an energy deficiency caused by orf224/atp6 may inhibit a series of genes that regulate pollen development through nuclear-mitochondrial interaction. This results in the sterility of pol CMS by leading to the failure of sporogenous cell differentiation. This study may provide assistance for detailed molecular analysis and a better understanding of pol CMS in B. napus.

  14. Radiation Fusion Technology for Sewage Sterilization

    International Nuclear Information System (INIS)

    Lee, M. J.; Kim, T. H.; Ryu, S. H.; Jung, I. H.; Lee, O. M.; Kim, T. H.

    2011-01-01

    Environmental regulation for effluent of sewage and wastewater treatment plant is going to be reinforced in terms of ecology toxicity and number of E.coli from 2011. Besides, it has been known that UV technology is not enough to be a sterilization tool due to regrowth of E.coli even after treatment with UV. Therefore it needs a novel technology for both restriction of E.coli regrowth and treatment of toxic materials in order to meet the environmental regulation being enforced. Electron beam has unique capabilities on destruction of chemicals and sterilization of microbial. In this study, field study on destruction of antibiotics and endocrine disruptors, reduction ecological toxicity and E.Coli regrowth was carried out using by mobile electron beam accelerator. Experimental results showed that irradiation on effluent could effectively reduce not only ecology toxicity but regrowth of E.coli by destruction of chemicals and complete sterilization

  15. Mechanisms of male sterility in higher plants

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Yasuo [Tsukuba Univ., Sakura, Ibaraki (Japan)

    1982-03-01

    The mechanisms causing male sterility in higher plants were classified into two major categories: genetic and non-genetic. The former was further divided into six classes: 1) Anomality in spindle mechanism during meiosis, 2) chromosomal anomality such as haploidy, polyploidy, aneuploidy, chromosome some deficiency, inversion and reciprocal translocation, 3) presence of male sterile genes, 4) cytoplasmic abnormality, 5) the combination of some specific cytoplasm with particular genes, and 6) infections of microorganisms or viruses. Each mechanism was briefly explained, and the methods for the maintenance of parent lines for heterosis breeding and hybrid seed production were described. The non-genetic male sterility was classified into four types, which are caused by 1) low or high temperature, 2) water deficiency, 3) application of chemicals, and 4) radiation, with a brief explanation given for each of them.

  16. Mechanisms of male sterility in higher plants

    International Nuclear Information System (INIS)

    Ohta, Yasuo

    1982-01-01

    The mechanisms causing male sterility in higher plants were classified into two major categories: genetic and non-genetic. The former was further divided into six classes: 1) Anomality in spindle mechanism during meiosis, 2) chromosomal anomality such as haploidy, polyploidy, aneuploidy, chromosome some deficiency, inversion and reciprocal translocation, 3) presence of male sterile genes, 4) cytoplasmic abnormality, 5) the combination of some specific cytoplasm with particular genes, and 6) infections of microorganisms or viruses. Each mechanism was briefly explained, and the methods for the maintenance of parent lines for heterosis breeding and hybrid seed production were described. The non-genetic male sterility was classified into four types, which are caused by 1) low or high temperature, 2) water deficiency, 3) application of chemicals, and 4) radiation, with a brief explanation given for each of them. (Kaihara, S.)

  17. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Vijaya Krishnan

    2004-12-01

    Full Text Available Prior to early 1970s, traditional methods were the principal means of controlling the number and spacing of births. Today, an estimated 57 per cent of the world’s married women use contraceptives and half use modern methods such as medical sterilizations. Recent statistics suggest that Canada has the highest sterilization rate in the Western world. This paper presents findings of research examining sterilization trends in Canada with respect to changing patterns in the use of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995 General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligation and an increase in the use of hysterectomy over the period 1984-1995. Less educated women are more likely to be in the forefront of modern methods of contraception.

  18. Modelling the effects of the sterile insect technique applied to Eldana saccharina Walker in sugarcane

    Directory of Open Access Journals (Sweden)

    L Potgieter

    2012-12-01

    Full Text Available A mathematical model is formulated for the population dynamics of an Eldana saccharina Walker infestation of sugarcane under the influence of partially sterile released insects. The model describes the population growth of and interaction between normal and sterile E.saccharina moths in a temporally variable, but spatially homogeneous environment. The model consists of a deterministic system of difference equations subject to strictly positive initial data. The primary objective of this model is to determine suitable parameters in terms of which the above population growth and interaction may be quantified and according to which E.saccharina infestation levels and the associated sugarcane damage may be measured. Although many models have been formulated in the past describing the sterile insect technique, few of these models describe the technique for Lepidopteran species with more than one life stage and where F1-sterility is relevant. In addition, none of these models consider the technique when fully sterile females and partially sterile males are being released. The model formulated is also the first to describe the technique applied specifically to E.saccharina, and to consider the economic viability of applying the technique to this species. Pertinent decision support is provided to farm managers in terms of the best timing for releases, release ratios and release frequencies.

  19. Ozone--the latest advance in sterilization of medical devices.

    Science.gov (United States)

    Murphy, Lorna

    2006-06-01

    How many times have procedures in your operating rooms been delayed because the instruments needed were still in the sterilizer? As Perioperative nurses you are likely to be quite familiar with the constant pressure to ensure that scarce instrumentation is available when needed. In 2003, a Canadian company developed a unique sterilization process employing ozone as the sterilizing agent. This technology is a safe, rapid and economical alternative to other low temperature sterilization modalities and may relieve some of the pressure experienced when instruments in short supply are in high demand. This article will discuss the principles of the sterilizer and the cycle and will explore the advantages of using this sterilization technology.

  20. Sterilization processes. Meeting the demands of today's health care technology.

    Science.gov (United States)

    Crow, S

    1993-09-01

    Universal Precautions dictate sterilization for all invasive equipment that break the blood barrier; however, current methods of sterilization, such as steam and ethylene oxide gas (ETO), are not compatible with many of the delicate, heat-sensitive surgical instruments used in modern health care. In addition, traditional sterilization methods are often too time consuming for practical use in the operating room. Clearly, new sterilization processes need to be developed. In this article, the criteria modern sterilization processes must meet and how some manufacturers plan to meet this challenge are discussed. In addition, the pros and cons of using peracetic acid (the newest sterilization process currently available) are examined.

  1. Dynamic sterilization of titanium implants with ultraviolet light

    International Nuclear Information System (INIS)

    Singh, S.; Schaaf, N.G.

    1989-01-01

    All implantable devices must be sterile. However, autoclaves produce poor surface properties that jeopardize the integration process. The application of a modified ultraviolet light source has proven to enhance bioreactivity by controlling surface properties, but it lacks validation of its sterilization capabilities. Forty-eight titanium implants were contaminated with spores of the biological indicator Bacillus stearothermophilus and subjected to dynamic sterilization by ultraviolet light. Forty-seven of the implants were successfully sterilized, as indicated by not producing turbidity in a suitable growth medium. This sterilization technique only requires a 20-second exposure to achieve sterility

  2. Induced mutant for male sterility in niger

    International Nuclear Information System (INIS)

    Sujatha, M.

    2001-01-01

    Full text: Niger (Guizotia abyssinica Cass.), an important oilseed crop of the family Compositae is highly cross-pollinated due to the twin mechanisms of protandry and incompatibility. Studies revealed the functional nature of protandry and the breakdown of incompatibility with alteration in temperature. It has very small flowers (disc florets) arranged in a capitulum that open on 3-4 consecutive days which pose problems in emasculation for cross-breeding. To induce mutations, seeds of variety 'IGP-76' were irradiated with γ-rays 200 to 1000 Gy. All seeds of M 1 plants were sown separately in individual plant-to progeny rows. The results of screening of M 2 segregating material indicated that γ-ray treatment was effective in induction of male sterility. Frequency of visible mutations were higher in sibbed progeny as compared to open pollinated population and male sterile plants were observed only in sibbed population (1000 Gy). Male sterile plants could easily be identified at the flowering stage by their altered floral morphology (disc florets transformed into ligulate ray florets) and complete absence or presence of a rudimentary anther column. Seeds were collected following sib-mating with the fertile counterparts. Progeny segregated in a ration of 3 normal : 1 male sterile. Further work on the mechanism of sterility, maintenance and linkage relationships with associated characters is under progress. This is the first report of induction of male sterility in niger through the use of physical mutagens. The availability of this mutant will be of great value for exploitation of heterosis on commercial basis. (author)

  3. Mass-rearing for sterile insect release

    International Nuclear Information System (INIS)

    Parker, A.G.

    2005-01-01

    As the sterile insect technique (SIT) relies upon released sterile male insects efficiently competing with wild males to mate with wild females, it follows that mass-rearing of insects is one of the principal steps in the process. Mass-rearing for the SIT presents both problems and opportunities due to the increased scale involved compared with rearing insects for most other purposes. This chapter discusses facility design, environmental concerns, strain management, quality control, automation, diet, sex separation, marking, and storage in relation to rearing for the SIT. (author)

  4. Radiation sterilization of pharmaceuticals and biomedical products

    International Nuclear Information System (INIS)

    Blackburn, R.; Iddon, B.; Moore, J.S.; Phillips, G.O.; Power, D.M.; Woodward, T.W.

    1975-01-01

    Sterilization of pharmaceuticals by radiation is accompanied by chemical degradation which must be eliminated or minimised if the method is to be successfully applied. In order to devise ways in which the pharmaceutical can be protected it is necessary to know the yield and nature of the decomposition products, the mechanisms by which degradation occurs, and the rate constants for the reactions involved. We have obtained such data for a variety of pharmaceutical compounds, viz. vitamin B12, benzyl penicillin, sulphonamides, indoles, heparin, alginates and phenylmercurics, both in the solid state and in aqueous solution. The scope and limitations of radiation sterilization are discussed in the light of these results. (author)

  5. Radiation sterilization of pharmaceuticals (eg chloramphenicol)

    International Nuclear Information System (INIS)

    Zeegers, F.; Tilquin, B.

    1991-01-01

    In connection with the ongoing world-wide application of irradiation as a new technology for sterilization, the identification of the drugs products is very important. Introduction of radiosterilization of pharmaceuticals is proceeding at a slower rate than that for disposable medical supplies; it is the responsibility of the manufacturer to prove that degradation of products is safe. Major advantages in the use of radiation as a sterilization procedure are high penetrating power, small temperature rise, ease of control and minimal degradation of irradiated solid drugs [fr

  6. Hysteroscopic tubal sterilization: a health economic literature review.

    Science.gov (United States)

    2013-01-01

    Hysteroscopic sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. In contrast to the laparoscopic technique, a hysteroscope is used to pass permanent microinserts through the cervix and place them in the fallopian tubes. This procedure does not require local or general anesthesia and can be performed in an office setting. The objective of this analysis was to determine, based on published literature, the cost-effectiveness of hysteroscopic tubal sterilization (HS) compared with laparoscopic tubal ligation (LS) for permanent female sterilization. A systematic literature search was conducted for studies published between January 1, 2008, and December 11, 2012. Potentially relevant studies were identified based on the title and abstract. Cost-utility analyses (studies that report outcomes in terms of costs and quality-adjusted life-years) were prioritized for inclusion. When not available, cost-effectiveness, cost-benefit, and cost-consequence analyses were considered. Costing studies were considered in the absence of all other analyses. A total of 33 abstracts were identified. Three cost analyses were included. A retrospective chart review from Canada found that HS was $111 less costly than LS; a prospective activity-based cost management study from Italy reported that it was €337 less costly than LS; and the results of an American decision model showed that HS was $1,178 less costly than LS. All studies had limited applicability to the Ontario health care system due to differences in setting, resource use, and costs. Three cost analyses found that, although the HS procedure was more expensive due to the cost of the microinserts, HS was less costly than LS overall due to the shorter recovery time required. Hysteroscopic sterilization is a minimally invasive alternative to conventional tubal ligation for women who want a permanent method of contraception. Both approaches involve closing off the

  7. Evaluation of user input methods for manipulating a tablet personal computer in sterile techniques.

    Science.gov (United States)

    Yamada, Akira; Komatsu, Daisuke; Suzuki, Takeshi; Kurozumi, Masahiro; Fujinaga, Yasunari; Ueda, Kazuhiko; Kadoya, Masumi

    2017-02-01

    To determine a quick and accurate user input method for manipulating tablet personal computers (PCs) in sterile techniques. We evaluated three different manipulation methods, (1) Computer mouse and sterile system drape, (2) Fingers and sterile system drape, and (3) Digitizer stylus and sterile ultrasound probe cover with a pinhole, in terms of the central processing unit (CPU) performance, manipulation performance, and contactlessness. A significant decrease in CPU score ([Formula: see text]) and an increase in CPU temperature ([Formula: see text]) were observed when a system drape was used. The respective mean times taken to select a target image from an image series (ST) and the mean times for measuring points on an image (MT) were [Formula: see text] and [Formula: see text] s for the computer mouse method, [Formula: see text] and [Formula: see text] s for the finger method, and [Formula: see text] and [Formula: see text] s for the digitizer stylus method, respectively. The ST for the finger method was significantly longer than for the digitizer stylus method ([Formula: see text]). The MT for the computer mouse method was significantly longer than for the digitizer stylus method ([Formula: see text]). The mean success rate for measuring points on an image was significantly lower for the finger method when the diameter of the target was equal to or smaller than 8 mm than for the other methods. No significant difference in the adenosine triphosphate amount at the surface of the tablet PC was observed before, during, or after manipulation via the digitizer stylus method while wearing starch-powdered sterile gloves ([Formula: see text]). Quick and accurate manipulation of tablet PCs in sterile techniques without CPU load is feasible using a digitizer stylus and sterile ultrasound probe cover with a pinhole.

  8. Present studies on the radio-sterilized drugs

    International Nuclear Information System (INIS)

    Marciniec, B.; Dettlaff, K.

    2007-01-01

    Lecture presents present status of radiosterilization of drugs and medical materials as compared to other sterilization methods. Literature review is shown on degradation of different kinds of drugs sterilized upon action of the sterilising doses of radiation

  9. Unintended pregnancies after Essure sterilization in the Netherlands

    NARCIS (Netherlands)

    Veersema, S.; Vleugels, M.P.; Moolenaar, L.M.; Janssen, C.A.; Brölmann, H.A.M.

    2010-01-01

    Objective: To analyze the data of cases of unintended pregnancies after Essure sterilization. Design: Retrospective case series analysis. Setting: National multicenter. Patient(s): Ten cases of unintended pregnancies after Essure sterilization in the Netherlands were reported from August 2002

  10. Bilateral cornual abscess after endometrial ablation following Essure sterilization.

    NARCIS (Netherlands)

    Jansen, N.E.; Vleugels, M.P.; Kluivers, K.B.; Vierhout, M.E.

    2007-01-01

    Endometrial ablation is used extensively to treat dysfunctional bleeding. Since the introduction of Essure tubal sterilization, this permanent contraception method has been widely used. Both endometrial ablation and Essure sterilization are procedures reported to have only a few complications. We

  11. Red oak borers become sterile when reared under continuous light

    Science.gov (United States)

    Jimmy R. Galford

    1975-01-01

    Red oak borers, Enaphalodes rufulus (Haldeman), reared under continuous light for 12 weeks became sterile. Sterility is thought to have been caused by light destroying vitamins essential for fertility

  12. Gamma radiation sterilization of Bactrocera invadens (Diptera ...

    African Journals Online (AJOL)

    The African invader fly, Bactrocera invadens, an invasive pest in Africa since 2003, causes damage and poses a threat to the mango and horticultural industry. Its control is therefore needed. Sterilization of males using gamma radiation doses (25, 50 and 75 Gy) as a means of population control was investigated. Irradiation ...

  13. Sterilization of heparinized cuprophan hemodialysis membranes

    NARCIS (Netherlands)

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated.

  14. Heat sterilization times of five hardwood species

    Science.gov (United States)

    William T. Simpson; Xiping Wang; John W. Forsman; John R. Erickson

    2005-01-01

    Heat sterilization of lumber, timbers, and pallets is currently used to kill insects, thus preventing their transfer between countries in international trade. An important factor in this treatment is the time required for the center of any wood configuration to reach the temperature necessary to kill the insect. This study explored the effect of size (1-, 1.5-, and 2.0...

  15. Sterilization of spices through ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Heins, H G; Ulmann, R M

    1971-10-01

    Sterilization of spices is discussed in relation to other methods. Efficiency, organoleptic inspection and costs of the treatment are considered. It is concluded that the irradiation method is feasible and acceptable with respect to taste and juridicial requirements. (G.J.P.). 12 refs.; 1 figure; 4 tabs.

  16. Perspectives: Eugenics and Sterilization in the Heartland.

    Science.gov (United States)

    Wehmeyer, Michael L.

    2003-01-01

    Noting the Governor of Virginia's recent apology for his state's participation in eugenics, this article reviews the history of the sterilization of people with epilepsy and mental retardation in several states, and the importance of the Buck v. Bell (1927) Supreme Court decision in the promotion of eugenics. (Contains references.) (CR)

  17. Utilization of male sterility in forage crops

    International Nuclear Information System (INIS)

    Suginobu, Ken-ichi

    1982-01-01

    The genetic nature of male sterility in forage crops was reviewed. Many workers have suggested that hybrids in forage crops are quite promising. First, the selection of the most desirable parental genotype from a large original population is improtant in heterosis breeding programs. After the more promising inbreds or clones have been selected on the basis of good general combining ability, it is necessary to identify the particular single, three-way or double cross that will produce the highest yields. A high seed yield potential is also important in a new variety so that the seeds can be sold at lower prices than other varieties. A tentative scheme for hybrid seed production by using inbred lines of male sterile or normal parents is proposed. At a breeding station, the seeds for male sterile F 1 (AB), maintainer S 1 (C-S 1 ) and either maintainer or restorer S 1 s(D-S 1 , E-S 1 ) are produced from the parental clones. At a seed increase agency, the seeds for male sterile F 1 (ABC) and either maintainer or restorer S 2 (D-S 2 ) are produced. In the case that D-S 2 seed production is difficult, maintainer or restorer F 1 (DE) should be produced from D-S 1 x E-S 1 . These seeds are used for commercial seed production. Seeds of hybrid F 1 (ABCD) or hybrid F 1 (ABCDE) are for practical use. (Kaihara, S.)

  18. Process variation in electron beam sterilization

    International Nuclear Information System (INIS)

    Beck, Jeffrey A.

    2012-01-01

    The qualification and control of electron beam sterilization can be improved by the application of proven statistical analysis techniques such as Analysis of Variance (ANOVA) and Statistical Tolerance Limits. These statistical techniques can be useful tools in: •Locating and quantifying the minimum and maximum absorbed dose in a product. •Estimating the expected process maximum dose, given a minimum sterilizing dose. •Setting a process minimum dose target, based on an allowance for random measurement and process variation. •Determining the dose relationship between a reference dosimeter and process minimum and maximum doses. This study investigates and demonstrates the application of these tools in qualifying electron beam sterilization, and compares the conclusions obtained with those obtained using practices recommended in Guide for Process Control in Radiation Sterilization. The study supports the following conclusions for electron beam processes: 1.ANOVA is a more effective tool for evaluating the equivalency of absorbed doses than methods suggested in . 2.Process limits computed using statistical tolerance limits more accurately reflect actual process variability than the AAMI method, which applies +/−2 sample standard deviations (s) regardless of sample size. 3.The use of reference dose ratios lends itself to qualification using statistical tolerance limits. The current AAMI recommended approach may result in an overly optimistic estimate of the reference dose adjustment factor, as it is based on application of +/−2(s) tolerances regardless of sample size.

  19. Sterilization of Microorganisms by Ozone and Ultrasound

    Science.gov (United States)

    Krasnyj, V. V.; Klosovskij, A. V.; Panasko, T. A.; Shvets, O. M.; Semenova, O. T.; Taran, V. S.; Tereshin, V. I.

    2008-03-01

    The results of recent experimental methods of sterilization of microorganisms with the use of ozone and ultrasound are presented. The main aim was to optimize the process of sterilization in water solution taking into account the ozone concentration, the power of ultrasonic emitter and the temperature of water. In the present work, the ultrasonic cavitation with simultaneous ozone generation has been used. The high ozone concentration in water solution was achieved by two-barrier glow discharge generated at atmospheric pressure and a cooling thermo-electric module. Such a sterilizer consists of ozone generator in a shape of flat electrodes covered with dielectric material and a high-voltage pulsed power supply of 250 W. The sterilization camera was equipped with ultrasonic source operated at 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. The ozone concentration in the aqueous solution was 10 mg/1, whereas the ozone concentration at the output of ozone generator was 30 mg/1. The complete inactivation of spores took 15 min. Selection of the temperature of water, the ozone concentrations and ultrasonic power allowed to determine the time necessary for destroying the row of microorganisms.

  20. Whey powder sterilization by ionizing irradiation

    International Nuclear Information System (INIS)

    Todorovic, M.; Salatic, Z.; Markov, S.

    1988-01-01

    Whey powder was sterilized by gamma waves application. As a source of irridiation isotope 60Co was used in Institute of Nuclear sciences B oris Kidrich , Vincha-Belgrade (Yugoslavia). The applied doses were: a, b, c, d, and e Kgy. The dose d was radappertization. After whey powder irradiation no adverse changes of organoleptic properties were noticed

  1. Methods of medical sterilization; Metody sterylizacji medycznej

    Energy Technology Data Exchange (ETDEWEB)

    Stachowicz, W [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    Broad review of different (physical, chemical and mechanical) methods commonly used for medical materials sterilization have been performed. Among them the special attention have been played on radiosterilization. The advantages and weaknesses each of the presented method have been pointed out. 1 fig.

  2. STERILIZATION AND DISINFECTION IN A PRIVATE CLINIC

    African Journals Online (AJOL)

    Oral examination is done with a mirror and probe. The mirror is then washed under the tap water and disinfected in 'V3 sterilizing' fluid concentrate. The probe is placed in a tray with ... Protective glasses are worn additionally to the gloves and facemask, when cavity preparation. is being performed. The handpiece is wiped.

  3. Lack of insurance and parity influence choice between long-acting reversible contraception and sterilization in women postpregnancy.

    Science.gov (United States)

    Baldwin, Maureen K; Rodriguez, Maria I; Edelman, Alison B

    2012-07-01

    Disparities in postpregnancy contraception utilization exist, with low-income women disproportionately undergoing sterilization. We assessed the impact of increased intrauterine device (IUD) availability on rates of female sterilization. Hospital billing records were used to identify women with an IUD placement or sterilization within 1 year of a pregnancy at a university hospital between Oct 2005 and Jun 2007. Demographic data were compared between women receiving either an IUD or sterilization. There were 365 sterilizations and 223 IUD placements during the study period. IUD placements doubled over the study period from 6% to 12% of all deliveries, while sterilizations remained stable at 11% (pwomen with either public or private insurance who had financial access to both sterilization (n=253) and IUD (n=223). Women receiving sterilization were slightly older (mean age 31 years versus 30 years, p=.03), of higher parity (median three versus two, pwomen who received IUD. Approximately 45% of women delivering in Oregon in 2007 were publicly insured (2010 Maternal and Child Health Update: States Make Progress Towards Improving Systems of Care. National Governor's Association, Table 6. Available at http://www.nga.org/files/live/sites/NGA/files/pdf/MCHUPDATE2010.PDF, accessed Nov 2011). After adjusting for age, parity and type of delivery, women choosing sterilization were more likely to have public insurance than women choosing IUD (odds ratio 8.4, 95% confidence interval 4.7-14.9, pWomen choosing sterilization are more likely to have public insurance than women choosing IUD and may represent a continued trend toward nonreversible contraception among women of lower socioeconomic status despite available long-acting reversible methods. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    International Nuclear Information System (INIS)

    Parker, A.; Mehta, K.

    2007-01-01

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discuss optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [es

  5. Laparoscopic tubal sterilization reversal and fertility outcomes

    Directory of Open Access Journals (Sweden)

    K Jayakrishnan

    2011-01-01

    Full Text Available Purpose: The purpose of the study was two-fold. Firstly it was to assess the suitability for tubal recanalization and factors predicting successful laparoscopic recanalization. Secondly, it was to analyze the fertility outcomes and factors affecting the pregnancy rate following laparoscopic tubal recanalization. Materials and Methods: A retrospective chart review of prospectively followed-up 29 women at a tertiary care center seeking tubal sterilization reversal between May 2005 and February 2010 were included. Results: In 14 (48.3% women unilateral tubes were suitable and in only 3 women (10.3% bilateral tubes were suitable. All cases with laparoscopic tubal sterilization were suitable, whereas all cases with fimbriectomy were unsuitable for recanalization. In 6 (20.7% cases salphingostomy was performed as an alternative procedure to tubal reanastomosis. The overall pregnancy rate was 58.8%. In cases with sterilization by Pomeroy′s method, 4 out of 10 (40% conceived, whereas for laparoscopic tubal ligation cases 6 out of 7 (85.7% conceived (P=0.32. None of the patients with final tubal length <5 cm conceived (P=0.03. Comparing the age at recanalization, in women ≤30 years, 71.4% conceived, as compared with 50% when age of women was more than 30 years (P=0.37. Conclusions: The important factors determining the success of recanalization are technique of sterilization and the remaining length of the tube after recanalization. The gynecologist must use an effective technique of sterilization to minimize the failure rates, but at the same time, which causes minimal trauma, and aim at preserving the length of the tube so that reversal is more likely to be successful, should the patient′s circumstances change.

  6. Production of a sterile species via active-sterile mixing: An exactly solvable model

    Science.gov (United States)

    Boyanovsky, D.

    2007-11-01

    The production of a sterile species via active-sterile mixing in a thermal medium is studied in an exactly solvable model. The exact time evolution of the sterile distribution function is determined by the dispersion relations and damping rates Γ1,2 for the quasiparticle modes. These depend on γ˜=Γaa/2ΔE, with Γaa the interaction rate of the active species in absence of mixing and ΔE the oscillation frequency in the medium without damping. γ˜≪1, γ˜≫1 describe the weak and strong damping limits, respectively. For γ˜≪1, Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where θm is the mixing angle in the medium and the sterile distribution function does not obey a simple rate equation. For γ˜≫1, Γ1=Γaa and Γ2=Γaasin⁡22θm/4γ˜2, is the sterile production rate. In this regime sterile production is suppressed and the oscillation frequency vanishes at an Mikheyev-Smirnov-Wolfenstein (MSW) resonance, with a breakdown of adiabaticity. These are consequences of quantum Zeno suppression. For active neutrinos with standard model interactions the strong damping limit is only available near an MSW resonance if sin⁡2θ≪αw with θ the vacuum mixing angle. The full set of quantum kinetic equations for sterile production for arbitrary γ˜ are obtained from the quantum master equation. Cosmological resonant sterile neutrino production is quantum Zeno suppressed relieving potential uncertainties associated with the QCD phase transition.

  7. The male gametophytic sterility. 1 - Gametic sterilities and deletions in petunia

    International Nuclear Information System (INIS)

    Cornu, A.; Maizonnier, D.

    1982-01-01

    Terminal deletions induced by ionizing radiations in Petunia are not sexually transmitted. Cytogenetic study of plants with a heterozygous deletion and their progenies shows that this lack of transmission is accompanied by a gametic semi-sterility due to the fact that gametes carrying the deleted chromosome are not viable. The interest of such a male sterility with a gametophytic determinism for the study of sporophyte-gametophyte relationships is underlined [fr

  8. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period (minutes) Directions T303-b-1 10 lbs 20 Use 28″ vacuum. Steam sterilization is not practical for treatment...

  9. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to...

  10. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by the...

  11. Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.

    Science.gov (United States)

    Mann, A; Kiefer, M; Leuenberger, H

    2001-03-01

    High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions.

  12. [Hysteroscopic tubal sterilization with Essure® devices: a retrospective descriptive study and evaluation of hypnosis].

    Science.gov (United States)

    Gauchotte, E; Masias, C; Bogusz, N; Koebele, A

    2011-06-01

    The Essure(®) system is a hysteroscopic sterilization method. The aim of our study is to retrospectively evaluate the sterilization procedure with Essure(®) devices, with and without anesthesia, and in particular with hypnosis. The descriptive study includes all tubal sterilization with Essure(®) performed during the year 2009 at the Maternité régionale de Nancy. Hypnosis efficiency is retrospectively evaluated with Verbal Numeric Rating Scale (VNRS) for peroperative pain, and analgesic medication use for postoperative pain. Ninety-four sterilizations are performed, 85% (85/94) of them without anesthesia. The mean VNRS is 3.0. The mean operative time is 8.7 minutes, positively correlated with the VNRS (P=0.0005). The rate of successful insertion is 94%. At 3 months, 91% of the implants have a correct location. Inadequate locations are more frequent when anesthesia have been performed (37% vs 4%, P=0.016). There is no significant difference between groups with and without hypnosis for the VNRS, the failure rate and the use of analgesic medication. Tubal sterilization with the Essure(®) system is a quick and efficient method. Our study does not demonstrate efficiency of hypnosis in pain control. This remains to be explored with a prospective study, including others parameters, such as anxiety. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  13. Development of cytoplasmic-nuclear male sterility, its inheritance, and potential use in hybrid pigeonpea breeding.

    Science.gov (United States)

    Saxena, Kul B; Ravikoti, V Kumar; Dalvi, Vijay A; Pandey, Lalji B; Gaddikeri, Guruprasad

    2010-01-01

    Pigeonpea [Cajanus cajan (L.) Millsp.] is a unique food legume because of its partial (20-30%) outcrossing nature, which provides an opportunity to breed commercial hybrids. To achieve this, it is essential to have a stable male-sterility system. This paper reports the selection of a cytoplasmic-nuclear male-sterility (CMS) system derived from an interspecific cross between a wild relative of pigeonpea (Cajanus sericeus Benth. ex. Bak.) and a cultivar. This male-sterility source was used to breed agronomically superior CMS lines in early (ICPA 2068), medium (ICPA 2032), and late (ICPA 2030) maturity durations. Twenty-three fertility restorers and 30 male-sterility maintainers were selected to develop genetically diverse hybrid combinations. Histological studies revealed that vacuolation of growing tetrads and persistence of tetrad wall were primary causes of the manifestation of male sterility. Genetic studies showed that 2 dominant genes, of which one had inhibitory gene action, controlled fertility restoration in the hybrids. The experimental hybrids such as TK 030003 and TK 030009 in early, ICPH 2307 and TK 030625 in medium, and TK 030861 and TK 030851 in late maturity groups exhibited 30-88% standard heterosis in multilocation trials.

  14. Sterilization of ready to eat meals destined to immunocompromised by irradiation

    International Nuclear Information System (INIS)

    Berhouma, Hiba

    2011-01-01

    Immunocompromised patients who have a dysfunction in one or more components of the immune system must follow a diet low in bacteria. Several methods are used to obtain this type of system such as pasteurization (65-10 degree), wet sterilization (120 degree - 140 degree UHT) or dry ( 180 degree), heating in the oven convection ((250 degree) and radappertization). In Tunisia, the CNGMO uses sterilization in a forced air oven 120 degree for 20 min. Of high radiation doses 5, 10 and 15 KGy were used in this study to achieve sterilization of Couscous. The dose of 5 KGy improves the bacteriological quality (reduce the microbial load of 2048 to 1 log CFU/g) of this dish while preserving the organoleptic qualities. The comparison sample irradiated 5 KGy and the heat-treated seems to be very close during the various tests. except that the heat-treated has a high oxidation state (TBARS value of 7900.90 mg / kg).

  15. Sterilization of solutions for parenterals products. Problem analysis

    Directory of Open Access Journals (Sweden)

    Yanelys Montes-González

    2017-09-01

    Full Text Available The solutions for the formulation of parenteral products must be sterile before the aseptic formulation process. For this reason, different methods of sterilization referred in the literature are analyzed. Thermodynamic criteria that rule the sterilization are presented. Furthermore, previous experiences in the sterilization of solutions for the formulation of parental products in an autoclave are analyzed, that take large time of processing and only low volumes of solution can be handled. Using jacketed stirred tanks for the sterilization may solve the problem and, therefore, criteria for the design of the later that allow to process high volumes of solution for the formulation of parenteral products are shown.

  16. Quality Control for Expanded Tsetse Production, Sterilization and Field Application

    International Nuclear Information System (INIS)

    2012-07-01

    The use of the sterile insect technique (SIT) for the control of pest insects as part of an integrated, area-wide approach is widely accepted. Its application for the eradication of different tsetse flies, the vectors of human sleeping sickness and African animal trypanosomosis, is attracting increasing interest. Following several initial demonstrations of the application of the SIT for tsetse control the technique was applied on the island of Unguja, Zanzibar, in the mid-1990s and, as the final component of an integrated control programme, led to the eradication of the only tsetse species on the island, Glossina austeni. This successful programme encouraged a number of countries to embark on projects with an SIT component for tsetse control, most Ethiopia. In 2001 the Pan African Tsetse and Trypanosomosis Eradication Campaign (PATTEC) was launched by the Organization of African Unity (now African Union, AU) and, subsequently, six countries obtained funding from the African Development Bank (AfDB) in 2005 to support control programmes with an SIT component. A further six countries have subsequently requested AfDB funding for their programmes. The FAO/IAEA coordinated research project (CRP) on Automation for Tsetse Mass Rearing For Use in Sterile Insect Technique Programmes, which was completed in 2001, led to the development of a semi-automated system for tsetse production. Using this new system, a large rearing facility was established in Addis Ababa, Ethiopia, to supply sterile males for an elimination programme in the southern Rift Valley. The development of large-scale rearing highlighted the need for improved quality control procedures and, with this in mind, the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture established a CRP in 2003 entitled Improved and Harmonized Quality Control for Expanded Tsetse Production, Sterilization and Field Application with the Objective of Improving and Expanding the Quality Control Sections of the FAO

  17. Quality Control for Expanded Tsetse Production, Sterilization and Field Application

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-15

    The use of the sterile insect technique (SIT) for the control of pest insects as part of an integrated, area-wide approach is widely accepted. Its application for the eradication of different tsetse flies, the vectors of human sleeping sickness and African animal trypanosomosis, is attracting increasing interest. Following several initial demonstrations of the application of the SIT for tsetse control the technique was applied on the island of Unguja, Zanzibar, in the mid-1990s and, as the final component of an integrated control programme, led to the eradication of the only tsetse species on the island, Glossina austeni. This successful programme encouraged a number of countries to embark on projects with an SIT component for tsetse control, most Ethiopia. In 2001 the Pan African Tsetse and Trypanosomosis Eradication Campaign (PATTEC) was launched by the Organization of African Unity (now African Union, AU) and, subsequently, six countries obtained funding from the African Development Bank (AfDB) in 2005 to support control programmes with an SIT component. A further six countries have subsequently requested AfDB funding for their programmes. The FAO/IAEA coordinated research project (CRP) on Automation for Tsetse Mass Rearing For Use in Sterile Insect Technique Programmes, which was completed in 2001, led to the development of a semi-automated system for tsetse production. Using this new system, a large rearing facility was established in Addis Ababa, Ethiopia, to supply sterile males for an elimination programme in the southern Rift Valley. The development of large-scale rearing highlighted the need for improved quality control procedures and, with this in mind, the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture established a CRP in 2003 entitled Improved and Harmonized Quality Control for Expanded Tsetse Production, Sterilization and Field Application with the Objective of Improving and Expanding the Quality Control Sections of the FAO

  18. Genetic complexity underlying hybrid male sterility in Drosophila.

    Science.gov (United States)

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-02-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic basis of hybrid male sterility more complex than that of hybrid female sterility and inviability? To clarify this point, the D. simulans introgression of the cytological region 34D-36A to the D. melanogaster genome, which causes recessive male sterility, was dissected by recombination, deficiency, and complementation mapping. The 450-kb region between two genes, Suppressor of Hairless and snail, exhibited a strong effect on the sterility. Males are (semi-)sterile if this region of the introgression is made homozygous or hemizygous. But no genes in the region singly cause the sterility; this region has at least two genes, which in combination result in male sterility. Further, the males are less fertile when heterozygous with a larger introgression, which suggests that dominant modifiers enhance the effects of recessive genes of male sterility. Such an epistatic view, even in the less-related species, suggests that the genetic complexity is special to hybrid male sterility.

  19. A search for sterile neutrinos in MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Osiecki, Thomas Henry [Univ. of Texas, Austin, TX (United States)

    2007-01-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining Δm$2\\atop{23}$ and θ23 through the disappearance of vμ, MINOS is able to measure vμ → vsterile by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS.

  20. Radiation sterilization of pharmaceuticals and polymers

    International Nuclear Information System (INIS)

    Gopal, N.G.S.

    1978-01-01

    Radiation, in the form of high energy electrons as well as gamma radiation, has featured in the last 15 yr as a promising sterilization agent for many heat sensitive and ethylene oxide incompatible pharmaceuticals and polymers of medical usage. This article deals with (i) a comparison of the various methods of sterilization and their shortcomings, (ii) modes of interaction of radiation with matter, (iii) the types of radiation sources in common use, (iv) dosimetry, (v) dose rate effect, (vi) a literature survey of the radiation effect on pharmaceuticals in solid form as well as in aqueous solution and on polymers in the form of plastic medical products and (vii) the evaluation of the irradiated products. The effect of dose rate on the stability of these materials is emphasized. Either very little work has been done on the dose rate effect or the published information is scanty. The literature survey covers the recent period of 5 to 6 years. (author)

  1. A search for sterile neutrinos in MINOS

    International Nuclear Information System (INIS)

    Osiecki, Thomas Henry

    2007-01-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining Δm 23 2 and θ 23 through the disappearance of ν μ , MINOS is able to measure ν μ → ν sterile by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS

  2. Radiation sterilization of triple sugar iron agar

    International Nuclear Information System (INIS)

    Altmann, G.; Eisenberg, E.; Bogokowsky, B.

    1979-01-01

    Triple sugar iron agar (TSI), a medium used for the identification of enteric bacteria, was sterilized by gamma radiation using radiation doses of 750-2000 krad. The radio-sterilized medium, slightly modified by increasing its Phenol Red content, performed well when tested with different enterobacteriaceae and other gram negative bacteria. Growth, change of indicator reaction in slant and butt and formation of gas and H 2 S were equal in irradiated and autoclaved TSI. Slants of irradiated TSI in stoppered plastic tubes kept their diagnostic properties during storage for at least 4 months. Gamma irradiation appears to be an attractive and economical method of sterilising nutrient media in sealed tubes or other containers, avoiding the risk of contamination during processing. (author)

  3. Radiation Sterilization of Naturual Rubber Examination Gloves

    International Nuclear Information System (INIS)

    Jetawattana, S.; Na-Ranong, N.; Kajornchaiyakul, V.

    1998-01-01

    The sterilization dose setting by ISO 11137 method 1 was conducted for natural rubber examination gloves provided by a local factory. The suitable sterilization dose for an average product bioburden falls between 20 - 25 kilogray. Maximum dose of 25 or 50 kilogray results in no changes of tensile s and elongation at break. Samples of examination glove were irradiated using various doses between 10 - 50 kilogray. Analysis of soluble protein content using modified Lowry method was carried out and the results revealed that irradiation did not affect the decrement of soluble protein content in this case. However, thin film samples were prepared in laboratory and treated in the same procedure. The results were also the same. The results did not show any correlation. Two factors are possibly presumed : un consistency of samples and the irradiation of finished products could not affect those soluble proteins in rubber gloves

  4. Surgical sterilization of free-ranging wolves.

    Science.gov (United States)

    Spence, C E; Kenyon, J E; Smith, D R; Hayes, R D; Baer, A M

    1999-02-01

    The objective of the study was to determine whether surgical sterilization of both males and females in wolf pairs alters basic wolf social and territorial behaviors. Wolves were located from the air by snow-tracking methods and were tranquilizer-darted from a helicopter. Surgeries were performed either in a tent at the capture site or in a heated building in a nearby village. Six vasectomies and seven uterine horn ligations were performed in January and February of 1996 and 1997. Two females died: one likely related to the capture procedure, the other of a peritonitis unrelated to the surgery. One wolf had a litter. None of the wolves have shown changes in behavioral patterns. Surgical sterilization can be effective, but other, less invasive, fertility control techniques should be investigated.

  5. Utilization of male sterility in forage crops

    Energy Technology Data Exchange (ETDEWEB)

    Suginobu, Ken-ichi [National Grassland Research Inst., Nishinasuno, Tochigi (Japan)

    1982-03-01

    The genetic nature of male sterility in forage crops was reviewed. Many workers have suggested that hybrids in forage crops are quite promising. First, the selection of the most desirable parental genotype from a large original population is improtant in heterosis breeding programs. After the more promising inbreds or clones have been selected on the basis of good general combining ability, it is necessary to identify the particular single, three-way or double cross that will produce the highest yields. A high seed yield potential is also important in a new variety so that the seeds can be sold at lower prices than other varieties. A tentative scheme for hybrid seed production by using inbred lines of male sterile or normal parents is proposed. At a breeding station, the seeds for male sterile F/sub 1/(AB), maintainer S/sub 1/(C-S/sub 1/) and either maintainer or restorer S/sub 1/s(D-S/sub 1/, E-S/sub 1/) are produced from the parental clones. At a seed increase agency, the seeds for male sterile F/sub 1/(ABC) and either maintainer or restorer S/sub 2/(D-S/sub 2/) are produced. In the case that D-S/sub 2/ seed production is difficult, maintainer or restorer F/sub 1/(DE) should be produced from D-S/sub 1/ x E-S/sub 1/. These seeds are used for commercial seed production. Seeds of hybrid F/sub 1/(ABCD) or hybrid F/sub 1/(ABCDE) are for practical use.

  6. Thermal In-Pouch Microwave Sterilization

    Science.gov (United States)

    2012-01-09

    straints for heat-sterilized ( retort ) packaging materials. Table 1: Functional Contributions of Materials in Foil Laminations MATERIAL FUNCTIONS...shelf life of the packaged entree items through temperature and humidity changes typically seen throughout the extended shelf life of the items. 15...Barber Industrial Ct.. Villa Rica. GA 30180. Final Scientific Report Light Barrier for Non-Foil Packaging Contract No. W911QY-08-C-0132 Thermal In

  7. Sterile neutrinos in the early universe

    Energy Technology Data Exchange (ETDEWEB)

    Malaney, R.A. (Lawrence Livermore National Lab., CA (USA)); Fuller, G.M. (California Univ., San Diego, La Jolla, CA (USA). Dept. of Physics)

    1990-11-14

    We discuss the role played by right-handed sterile neutrinos in the early universe. We show how well known {sup 4}He constraint on the number of relativistic degrees of freedom at early times limits the equilibration of the right handed neutrino sea with the background plasma. We discuss how this allows interesting constraints to be placed on neutrino properties. In particular, a new limit on the Dirac mass of the neutrino is presented. 12 refs.

  8. Sterilization: new method options, failure rate info.

    Science.gov (United States)

    1998-01-01

    This article discusses new sterilization methods for tubal ligation, failure rates, and risks for ectopic pregnancy in the US. The Filshie clip, which was developed by Femcare, Ltd. in Nottingham, England, and is distributed by Avalon Medical Corp of Vermont, was approved by the US Food and Drug Administration in September 1996. The company has provided training sessions at major universities nationwide and exhibited at national professional association meetings. A training video and two more films will be available in 1998. The new clip is considered a more modern approach to a tubal occlusion method, which relies on newer materials and solves prior problems. Physicians usually used Falope rings, which had better failure rates than the Hulka clip and bipolar coagulation methods. There is a need for more long-term and large scale information exchange about the new Filshie clip. Some physicians still use the Falope ring because it is cost effective and well-studied. Physicians are warned to continue to advise women about the potential failure rates up to 10 years after sterilization and the 1 in 3 risk of ectopic pregnancy. Counseling about failure rates and the risk of ectopic pregnancy should target women under 30 years old, who have the highest failure rates, and women 30-34 years old. All sterilized women should be advised to seek a provider immediately if they have pregnancy symptoms following sterilization. Counseling should include the issue of "regrets," since it is a permanent method. All women should know about nonpermanent methods and experience a basic informed consent process. Young women and newly divorced women are particularly vulnerable to the "regrets" syndrome.

  9. Irradiation sterilization of semi-crystalline polymers

    International Nuclear Information System (INIS)

    Williams, J.; Dunn, T.; Stannett, V.

    1978-01-01

    A semi-crystalline polymer such as polypropylene, is sterilized by high energy irradiation, with the polymer containing a non-crystalline mobilizing additive which increases the free volume of the polymer, to prevent embrittlement of the polymer during and subsequent to the irradiation. The additive has a density of from 0.6 to 1.9 g/cm 3 and a molecular weight from 100 to 10,000 g/mole

  10. Dose mapping for documentation of radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1999-01-01

    The radiation sterilization standards EN 552 and ISO 11137 require that dose mapping in real or simulated product be carried in connection with the process qualification. This paper reviews the recommendations given in the standards and discusses the difficulties and limitations of practical dose...... mapping. The paper further gives recommendations for effective dose mapping including traceable dosimetry, documented procedures for placement of dosimeters, and evaluation of measurement uncertainties. (C) 1999 Elsevier Science Ltd. All rights reserved....

  11. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  12. Chemical and biological effects of radiation sterilization of medical products

    International Nuclear Information System (INIS)

    Gupta, B.L.

    1975-01-01

    Radiation is extensively used for the sterilization of plastic materials, pharmaceuticals and biological tissue grafts. The pharmaceuticals may be solid, liquid, or suspension in a liquid or a solution. Cobalt-60 gamma radiation, generally used for sterilization, primarily interacts with these materials through the Compton process. The resulting damage may be direct or indirect. In aqueous systems the primary species produced compete for interaction among themselves and the dissolved solutes. The nature, the G-values and the reactions of the primary species very much depend on the pH of the solution. The important chemical changes in plastic materials are gas liberation, change in concentration of double bonds, cross-linking, degradation and oxidation. These chemical changes lead to some physical changes like crystallinity, specific conductivity and permeability. The reactions in biological systems are very complex and are influenced by the presence or absence of water and oxygen. Water produces indirect damage and the radiation effect is generally more in the presence of oxygen. Most microorganisms are relatively radioresistant. Various tissues of an animal differ in their response to radiation. Catgut is not stable to irradiation. Lyophilized human serum is stable to irradiation whereas, when irradiated in aqueous solutions, several changes are observed. Generally, pharmaceuticals are considerably more stable in the dry solid state to ionizing radiations than in aqueous solutions or in any other form of molecular aggregation. (author)

  13. Development of a new water sterilization device with a 365 nm UV-LED.

    Science.gov (United States)

    Mori, Mirei; Hamamoto, Akiko; Takahashi, Akira; Nakano, Masayuki; Wakikawa, Noriko; Tachibana, Satoko; Ikehara, Toshitaka; Nakaya, Yutaka; Akutagawa, Masatake; Kinouchi, Yohsuke

    2007-12-01

    Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5 alpha, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device.

  14. Male sterility in chestnuts. A tentative plan for the seed propagation of fruit trees

    Energy Technology Data Exchange (ETDEWEB)

    Omura, Mitsuo; Akihama, Tomoya [Fruit Tree Research Station, Yatabe, Ibaraki (Japan)

    1982-03-01

    A tentative plan was proposed for chestnuts based on their pollination system, male sterility and restoration. The studies on the male sterility of 1,063 cultivars and clones suggested that there were three types of male sterility. The first type (S-1) was characterized by antherless florets. In the second type (S-2), the catkins fell before anthesis, and the third type (S-3) appeared to develop normally in gross floral morphology, but the pollen grains were abnormal in shape and did not have germinating power. In an interspecific hybrid clone CS which belonged to S-1, fertility was restored in an open pollinated progeny. The use of CS and CSO-3 with its restored fertility, permitted the planning of breeding the chestnut hybrid cultivars propagated by seeds. The inbred clones with either male sterility or restorer genes are first bred mainly by back crossing with parents with favorable pollen. The clones are selected individually for early bearing, wasp and disease resistance, and restoration. Then, the hybrid seedling lines between male sterile and restorer inbreds are evaluated for homogenity in nut characters and tree habits. Next, the hybrid seedling lines selected will be examined for crop yield, vigor and cross compatibility. The superior seedling lines are finally selected, and the parental inbreds are grafted to be propagated for seed production orchards.

  15. Sterilization of single-use helical stone baskets: an experimental study

    Directory of Open Access Journals (Sweden)

    Cely Barreto da Silva

    2011-03-01

    Full Text Available Objectives: To experimentally evaluate the efficacy of a standard sterilization protocol employed during reuse of disposable helical stone baskets. Methods: Study performed on 20 helical stone baskets: 10 were used in the initial validation process, contaminated with Escherichia coli ATCC 25922 and imprinted on Müeller-Hinton media; 10 catheters were contaminated with Geobacillus stearothermophilus ATCC 7953, processed, inoculated in TSB and incubated in a water bath at a temperature of 55ºC. Bacterial growth was evaluated after 1, 3, 5 and 7 days. After sterilization, stone baskets were also opened and closed 40 times to check for functional problems. All plastic and basket parts were carefully checked for damages. Results: After the 72-hour incubation period, there was growth of E. coli ATCC 25922 in 100% of imprints. After the sterilization process and up to 7 days incubation period on a blood agar plate, there was no growth of G. stearothermophilus ATCC 7953 or any other bacteria. There were no functional problems or damage to baskets after the sterilization process. Conclusion: The ethylene oxide system is efficacious and safe for sterilization of disposable helical stone baskets. However, further clinical studies are required and should provide more safety information.

  16. Sterilization of allograft bone: is 25 kGy the gold standard for gamma irradiation?

    Science.gov (United States)

    Nguyen, Huynh; Morgan, David A F; Forwood, Mark R

    2007-01-01

    For several decades, a dose of 25 kGy of gamma irradiation has been recommended for terminal sterilization of medical products, including bone allografts. Practically, the application of a given gamma dose varies from tissue bank to tissue bank. While many banks use 25 kGy, some have adopted a higher dose, while some choose lower doses, and others do not use irradiation for terminal sterilization. A revolution in quality control in the tissue banking industry has occurred in line with development of quality assurance standards. These have resulted in significant reductions in the risk of contamination by microorganisms of final graft products. In light of these developments, there is sufficient rationale to re-establish a new standard dose, sufficient enough to sterilize allograft bone, while minimizing the adverse effects of gamma radiation on tissue properties. Using valid modifications, several authors have applied ISO standards to establish a radiation dose for bone allografts that is specific to systems employed in bone banking. These standards, and their verification, suggest that the actual dose could be significantly reduced from 25 kGy, while maintaining a valid sterility assurance level (SAL) of 10(-6). The current paper reviews the methods that have been used to develop radiation doses for terminal sterilization of medical products, and the current trend for selection of a specific dose for tissue banks.

  17. Sterilization by ionizing radiation comparative evaluation

    International Nuclear Information System (INIS)

    Tata, A.; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 7 on beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems

  18. Counselling women considering or seeking sterilization.

    Science.gov (United States)

    Jackson, T

    1980-12-01

    The view of counseling as assessment and advice-giving places unrealistic and unnecessary stresses on both counselor and client. The counselor-doctor feels responsible for client's subsequent happiness in life and feels guilty if his advice leads to future unhappiness for her. The client feels powerless in the decision-making process and has less incentive to take full responsibility for the direction of her life. A review of studies of emotional adjustment to sterilization revealed a lack of clearly defined goals for preoperative counseling and the failure to test in any way the effect of different models of counseling on client outcome. Issues which might be raised with a woman considering sterilization may be grouped into 4: 1) the woman's life situation; 2) her reasons for considering sterilization; 3) timing; and 4) ambivalence. Counselors should be prepared for and comfortable with the expression of emotion in counseling sessions. Counselors who themselves are unable to cope with expression of intense emotion will send conflicting messages to clients, both giving permission for and disapproving of exploration of certain levels of feeling. The concept of 'regret' as an outcome measure should be refined.

  19. [Essure--a novel method of sterilization].

    Science.gov (United States)

    Revel, Ariel; Nadjary, Michel; Shushan, Asher

    2008-02-01

    Essure hysteroscopic sterilization is a minimally invasive, outpatient approach to female sterilization, which avoids the possible complications of laparoscopic sterilization. This procedure has been available since 2003 in both Europe and North America. We present our experience of the first 12 cases of the procedure performed in Israel. Women who have completed their family planning were offered to consider Essure as their permanent contraception. The procedure was performed without anesthesia by the vaginoscopic technique at the hospital's outpatient clinic. Patients completed a questionnaire and were discharged immediately following the procedure. A follow-up checkup was completed after three months including three dimensional sonography, abdominal X-ray and occasional hysterosalpingogram. Twelve patients participated in the pilot group at Hadassah. The average age was 40 years (34-45) and the average number of children was 5 (4-8). The average time for the procedure was under 8 minutes. Periostial adhesions required adhesiolysis prior to insertion of the device in one patient. All patients resumed their normal activity on the same day. Our patient satisfaction survey revealed that the procedure was associated with high satisfaction levels. Sonographic and radiographic studies confirmed the good placement of the device. The Essure procedure was well tolerated by patients. The limitation is probably going to be the price of Essure, as this procedure is not covered by the 'health basket' in Israel.

  20. Development of hydroponic system using agricultural waste. 2. Utilization of ozone for sterilization of nutrient solution; Suiko saibai ni okeru haikibutsu riyo gijutsu no kaihatsu. 2. Ozone ni yoru baiyoeki sakkin ni kansuru kento

    Energy Technology Data Exchange (ETDEWEB)

    Terazoe, H; Yoshihara, T; Nakaya, K [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1995-08-01

    Discussions were given on a sterilizing effect of ozone on Fusarium bacteria in hydroponic culture, and its effect on components in the culture solution. In an experiment, dry air with O3 concentration of 3.5 ppm was sent into aqueous solution inoculated with Fusarium bacteria at a flow rate of 5 liters per minute. The Fusarium bacteria was sterilized nearly completely in about five minutes. No change was observed in pH, EC and dissolved oxygen concentration of the O3-treated culture solution. However, iron and manganese among the soluble components have been oxidized by O3 and precipitated, hence these components must be added after the O3 treatment. In spinach culture performed on a culture medium inoculated with Fusarium bacteria, ozone water containing dissolved O3 at 0.8 ppm was flown into a urethane foam medium and vegetable roots. This treatment has resulted in reduction of the number of strains occurred with a wilt symptom below that in the section flown with distilled water. The spinach has grown normally without showing an effect of the ozone water. 15 refs., 10 figs., 3 tabs.

  1. Sterilization of health care products - Radiation. Part 2: Establishing the sterilization dose

    International Nuclear Information System (INIS)

    2006-01-01

    This part of ISO 11137 describes methods that may be used to establish the sterilization dose in accordance with one of the two approaches specified in 8.2 of ISO 11137-1:2006. The methods used in these approaches are: a) dose setting to obtain a product-specific dose; b) dose substantiation to verify a preselected dose of 25 kGy or 15 kGy. The basis of the dose setting methods described in this part of ISO 11137 (Methods 1 and 2) owe much to the ideas first propounded by Tallentire (Tallentire, 1973 [17]; Tallentire, Dwyer and Ley, 1971 [18]; Tallentire and Khan, 1978 [19]). Subsequently, standardized protocols were developed (Davis et al., 1981 [8]; Davis, Strawderman and Whitby, 1984 [9]) which formed the basis of the dose setting methods detailed in the AAMI Recommended Practice for Sterilization by Gamma Radiation (AAMI 1984, 1991 [4], [6]). Methods 1 and 2 and the associated sterilization dose audit procedures use data derived from the inactivation of the microbial population in its natural state on product. The methods are based on a probability model for the inactivation of microbial populations. The probability model, as applied to bioburden made up of a mixture of various microbial species, assumes that each such species has its own unique D 10 value. In the model, the probability that an item will possess a surviving microorganism after exposure to a given dose of radiation is defined in terms of the initial number of microorganisms on the item prior to irradiation and the D 10 values of the microorganisms. The methods involve performance of tests of sterility on product items that have received doses of radiation lower than the sterilization dose. The outcome of these tests is used to predict the dose needed to achieve a predetermined sterility assurance level, SAL. Methods 1 and 2 may also be used to substantiate 25 kGy if, on performing a dose setting exercise, the derived sterilization dose for an SAL of 10 -6 is u ≤25 kGy. The basis of the method

  2. [Assessment of disinfection and sterilization processes in dental practice as an important factors in prevention of infections].

    Science.gov (United States)

    Podgórska, Marta; Jakimiak, Bozenna; Röhm-Rodowald, Ewa; Chojecka, Agnieszka

    2009-01-01

    The dental health-care settings is an environment where disease transmission occurs easily. Prevention of cross infection is therefore a crucial aspect of dental practice and dental clinic stuffmust adopt certain basic routines while practicing. Infections may be transmitted in the dental operatory through direct contact with blood, oral fluids or other secretions; via indirect contact with contaminated instruments, equipment or environmental surfaces; or by contact with airborne contaminants present in either droplet splatter or aerosols of oral and respiratory fluids. Strategies to prevent dental patient infections have focused on disinfection and sterilization. This study evaluates basic routines in prevention of cross-infection in the dentistry. The sample comprised 100 dentists, who completed questionnaires. Based on inquires the conditions for disinfection and sterilization of medical devices were assessed. The following issues were taken into consideration: the way of disinfection and preparation of the disinfectants, the localization of disinfection, preparing to disinfection, washing and packing of dental devices, the frequency of disinfection, methods of sterilization and the monitoring system, type of sterilizers and the available cycles. The dental practices are well equiped to proceed the steam sterilization, but 33% of dentists don't know the available cycles in their autoclaves. Only 35% of them made sterilization process protocols. Very common are three failures of instruments disinfections: multiple use of disinfectant, adding of disinfectant, adding new instruments. There is still need for improvement in disinfection and sterilization in dental practice, especially including: monitoring and documentation of sterilization process, proper use of disinfectants according to manufactures instructions, frequent disinfection of surfaces which contact with patients. Dental stuff should take part in advanced training courses about disinfection and

  3. Risk analysis of sterile production plants: a new and simple, workable approach.

    Science.gov (United States)

    Gapp, Guenther; Holzknecht, Peter

    2011-01-01

    A sterile active ingredient plant and a sterile finished dosage filling plant both comprise very complex production processes and systems. The sterility of the final product cannot be assured solely by sterility testing, in-process controls, environmental monitoring of cleanrooms, and media fill validations. Based on more than 15 years experience, 4 years ago the authors created a new but very simple approach to the risk analysis of sterile plants. This approach is not a failure mode and effects analysis and therefore differs from the PDA Technical Report 44 Quality Risk Management for Aseptic Processes of 2008. The principle involves specific questions, which have been defined in the risk analysis questionnaire in advance, to be answered by an expert team. If the questionnaire item is dealt with appropriately, the answer is assigned a low-risk number (1) and if very weak or deficient it gets a high-risk number (5). In addition to the numbers, colors from green (not problematic) through orange to red (very problematic) are attributed to make the results more striking. Because the individual units of each production plant have a defined and different impact on the overall sterility of the final product, different risk emphasis factors have to be taken into account (impact factor 1, 3, or 5). In a well run cleanroom, the cleanroom operators have a lower impact than other units with regard to the contamination risk. The resulting number of the analyzed production plant and the diagram of the assessment subsequently offers very important and valuable information about a) the risk for microbiological contamination (sterility/endotoxins) of the product, and b) the compliance status of the production plant and the risk of failing lots, as well as probable observations of upcoming regulatory agency audits. Both items above are highly important for the safety of the patient. It is also an ideal tool to identify deficient or weak systems requiring improvement and upgrade

  4. A satisfação com o serviço de esterilização cirúrgica entre os usuários do sistema único de saúde em um município paulista The satisfaction with surgical sterilization provision among the users of the unified health system in a city of São Paulo state

    Directory of Open Access Journals (Sweden)

    Elisabeth Meloni Vieira

    2011-12-01

    Full Text Available OBJETIVO: Avaliar a satisfação dos usuários com a esterilização cirúrgica realizada pelo Sistema Único de Saúde (SUS e detectar fatores que possam influenciar a escolha entre laqueadura e vasectomia. MÉTODOS: Foram entrevistados 235 mulheres e 78 homens esterilizados em um período de cinco anos. As variáveis estudadas incluíram as características sociodemográficas, os motivos para esterilizar-se, a facilidade para a obtenção do procedimento, o aconselhamento, a assistência hospitalar e a satisfação com a esterilização. RESULTADOS: A maioria dos entrevistados era casada ou coabitava com um companheiro(a e tinha em média 3,4 filhos vivos. Frequentaram a escola por 6,7 anos em média e declararam renda familiar per capita média de R$ 212,81 mensais, pertenciam à categoria social C, eram brancos e católicos. Consideraram fácil obter a cirurgia e adequado o tempo de espera, ficaram satisfeitos com o aconselhamento e com a esterilização. No entanto, cerca de um quarto ainda pensava, equivocadamente, ser a esterilização de fácil reversão. Estudando-se os casais, observaram-se diferenças importantes na escolha de vasectomia e laqueadura. CONCLUSÕES: Os resultados apontam para a necessidade de melhoria na informação fornecida aos candidatos ao procedimento que, embora estejam satisfeitos no momento, poderão não estar no futuro. A avaliação realizada na perspectiva do usuário deve levar em consideração não apenas a sua opinião, mas também seus interesses.OBJECTIVES: To evaluate the satisfaction with the surgical sterilization performed by Unified Health System (SUS and to detect factors that can influence the choice between tubal ligation and vasectomy. METHODS: A total of 235 women and 78 men who were sterilized in a five years time period were interviewed. The studied variables included their socio-demographic features, their reason for sterilization, their opinion on the access to the surgery, the

  5. One-step formation and sterilization of gellan and hyaluronan nanohydrogels using autoclave.

    Science.gov (United States)

    Montanari, Elita; De Rugeriis, Maria Cristina; Di Meo, Chiara; Censi, Roberta; Coviello, Tommasina; Alhaique, Franco; Matricardi, Pietro

    2015-01-01

    The sterilization of nanoparticles for biomedical applications is one of the challenges that must be faced in the development of nanoparticulate systems. Usually, autoclave sterilization cannot be applied because of stability concerns when polymeric nanoparticles are involved. This paper describes an innovative method which allows to obtain, using a single step autoclave procedure, the preparation and, at the same time, the sterilization of self-assembling nanohydrogels (NHs) obtained with cholesterol-derivatized gellan and hyaluronic acid. Moreover, by using this approach, NHs, while formed in the autoclave, can be easily loaded with drugs. The obtained NHs dispersion can be lyophilized in the presence of a cryoprotectant, leading to the original NHs after re-dispersion in water.

  6. Essure hysteroscopic sterilization versus interval laparoscopic bilateral tubal ligation: a comparative effectiveness review.

    Science.gov (United States)

    Ouzounelli, Myrsini; Reaven, Nancy L

    2015-01-01

    A comparative effectiveness analysis was performed to examine the risks and benefits of laparoscopic bilateral tubal ligation compared with hysteroscopic sterilization using the Essure Permanent Birth Control System (Bayer HealthCare AG, Whippany, NJ). Existing evidence shows that both LBTL and Essure are safe and effective methods of female sterilization. Both have high rates of efficacy and low rates of complications although when complications do occur, those related to the Essure procedure are more likely to be minor in nature. The analysis was limited by the restricted number of studies involving head-to-head comparisons of the 2 approaches. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  7. Sensitivity of viruses to radiation sterilization

    International Nuclear Information System (INIS)

    Dziedzic Goclawska; A

    1999-01-01

    The hazard of infectious disease transmission with tissue allografts is a major concern in tissue banking practice. Microorganisms can be introduced into grafts during tissue collection, processing and storage, but even when all these procedures are performed under a septic conditions, the possibility of fungal, bacterial or viral disease transmission of donor origin can not be excluded. Therefore, in order to minimize the risk of infectious disease transmission, several steps should be undertaken, including a careful donor screening, proper tissue processing and sterilization of tissue allografts. The risk of transmission of viral infections such as hepatitis B, C, other viruses and particularly HIV with tissue allografts is of great significance and the search for sterilizing methods which inactivate and/or highly reduce viral infectivity continues. Sterilization of tissue allografts with ionizing radiation (introduced in the mid of 1950s) is increasingly used in tissue banking practice. The effectiveness of the radiation-sterilization procedure depends on the amount of energy transferred, the number of contaminating microorganisms and their resistance to ionizing radiation (initial contamination, bioburden). Usually, spores are more resistant than vegetative forms of bacteria, some fungi may be as resistant as bacterial spores, and viruses are, in general, more resistant than bacteria. Dita concerning effectiveness of ionizing radiation to inactivate viruses (e.g. such as HBV, HCV or HIV) in tissue allografts collected from cadavers are scarce. It has been found that the dose of irradiation needed to reduce HIV load by I log10 unit (D10) is about 4.0 kGy or even 5.6 kGy. The level of infectious HIV in plasma is usually evaluated by titration of tissue culture infective dose (TCID50/ml). Taking into consideration the recommended sterility assurance level (SAL) 10-6, assuming the HIV bioburden to be 103 TCID50/ml for the state of acute infection and D10 value of 4

  8. Pre-sterilization contamination of disposable medical products and the choice of minimum sterilization dose

    International Nuclear Information System (INIS)

    Horakova, V.; Buriankova, E.

    1975-01-01

    The bacterial contamination was assessed on randomly taken samples of blood-transfusion devices, donor sets, intra-uterine contraceptive devices and inserters, surgical gloves and dressing material prior to sterilization. The quantitative and qualitative efficiency of six nutrient media was compared. The best results were obtained with the enriched ''Universal'' medium. It was confirmed that the contamination of plastic products was low compared with dressing material. Most frequently, Gram-positive aerobic spore-forming rods and Gram-positive cocci were found on non-sterile medical disposable products. A method was tested to obtain a general informative picture of the resistance of bacteria on products. The methods used for choosing the dose for radiation sterilization of medical products are discussed. (author)

  9. Evaluation of steam sterilization conditions for [18F]fludeoxyglucose

    International Nuclear Information System (INIS)

    Santos, Priscilla F.; Nascimento, Leonardo T.; Valente, Eduardo S.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z.

    2011-01-01

    [ 18 F]Flu deoxyglucose ( 18 FDG) is the most commonly used radiopharmaceutical for positron emission tomography. Sterile filtration of the final product into sterile vials using 0.22 μm filter membrane is usually adopted for 18 FDG. However, Good Manufacturing Practice (GMP) guidelines recommend heat sterilization as the method of choice to ensure sterility of pharmaceutical preparations. The aim of this study was to essay different steam sterilization conditions in order to choose the best one for 18 FDG. Three different sterilization conditions were essayed. The first one at 121 deg C for 15 minutes, the second one at 135 deg C for 3.5 minutes and the third one at 133 deg C for 2 minutes. 18 FDG pH-formulation was kept around 6.0. At the end of autoclave cycles, 18 FDG sterility was evaluated by direct inoculation of 18 FDG in culture media and radiochemical purity was determined by TLC and HPLC. Results demonstrated that all essayed conditions were able to ensure 18 FDG sterility, but caused a decrease in radiochemical purity of 18 FDG. Autoclave cycle at 133 deg C for 2 minutes was the best essayed condition for 18 FDG terminal sterilization, once it provided the greater radiochemical purity value and took less time. 18 FDG was able to meet specifications after autoclave cycles, what supports the application of steam sterilization in routine 18 FDG production, in compliance with GMP. (author)

  10. Degradation of chitosan-based materials after different sterilization treatments

    International Nuclear Information System (INIS)

    San Juan, A; Montembault, A; Royaud, I; David, L; Gillet, D; Say, J P; Rouif, S; Bouet, T

    2012-01-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  11. Use of sterile insect technique in Brazil by the sterilization of Ceratitis capitata (Wied., 1824)

    International Nuclear Information System (INIS)

    Okeese, G.O.; Kitomer, T.J.; Gayaradus, L.B.; Etrigan, M.; Jansen, C.W.J.H.; Houlahar, H.L.

    2006-01-01

    The Sterile Insect Technique is a method of pest control allowed in Integrated Pest Management programs in fruit growing, where sterile insects released compete in mate process against fertile wild ones, generating a gradative population reduction. The most used sterilization method is using ionizing radiation from 60 Co or 137 Cs. For efficient application of SIT, an important item is the sterilizing dose. This must be as lower as possible in order to preserve insect behavior. In this work, it was studied the reproductive potential of fruit fly Ceratitis capitata, tsl VIENNA 8 strain, irradiated with different doses of gamma radiation. This strain has been used in population suppression programs at fruit-growing areas from Northeast of Brazil, through a partnership between CENA and Bio factory MOSCAMED Brazil, intending only sterile male releases. Radiation source used was a 60 Co irradiator, with 17.2 x 1012 Bq. Individualized couples were distributed in a randomized delineament with 10 replicates for each treatment and eggs were collected for fifteen days. With 9 and 10 days old, pupae were irradiated with doses ranging from 30 to 120 Gy. All averages of emerged adult's percentages were higher than 90%. In regards to fecundity, different doses did not affect the number of eggs laid, being the overall mean around 30 eggs/couple/day. Fertility data showed that as radiation dose increases, sterility increases. It was concluded that the dose of 90 Gy can be used in Brazil, since to SIT programs a dose is chosen witch prevents an egg hatch higher than 1%. (author)

  12. Sterilization and decontamination of surfaces using atmospheric pressure plasma discharges

    Energy Technology Data Exchange (ETDEWEB)

    Garate, E.; Gornostaeva, O.; Alexeff, I.; Kang, W.L.

    1999-07-01

    The goal of the program is to demonstrate that an atmospheric pressure plasma discharge can rapidly and effectively sterilize or decontaminate surfaces that are contaminated with model biological and chemical warfare agents. The plasma is produced by corona discharge from an array of pins and a ground plane. The array is constructed so that various gases, like argon or helium, can be flowed past the pins where the discharge is initiated. The pin array can be biased using either DC. AC or pulsed discharges. the work done to date has focused on the sterilization of aluminum, polished steel and tantalum foil metal coupons, about 2 cm on a side and 2 mm thick, which have been inoculated with up to 10{sup 6} spores per coupon of Bacillus subtilis var niger or Bascillus stearothermorphilus. Results indicate that 5 minute exposures to the atmospheric pressure plasma discharge can reduce the viable spore count by 4 orders of magnitude. The atmospheric pressure discharge is also effective in decomposing organic phosphate compounds that are stimulants for chemical warfare agents. Details of the decomposition chemistry, by-product formation, and electrical energy consumption of the system will be discussed.

  13. Natural convection heating of liquids, with reference to sterilization of canned food

    NARCIS (Netherlands)

    Hiddink, J.

    1975-01-01

    In a model system the physical transport phenomena that occur during the sterilization of a canned liquid food were investigated. Flow phenomena and heat transfer were studied experimentally as well as theoretically. Experiments on flow patterns and temperature profiles revealed a boundary

  14. Is parotid saliva sterile on entry to the oral cavity?

    DEFF Research Database (Denmark)

    Schrøder, Stine A; Bardow, Allan; Eickhardt-Dalbøge, Steffen

    2017-01-01

    CONCLUSION: The present study indicates that parotid saliva is sterile on entry to the oral cavity. OBJECTIVES: The objective was to investigate if parotid saliva is sterile on entry to the oral cavity and, thus, prior to contamination by oral bacteria. METHOD: Forty healthy volunteers were...... included in sterile parotid saliva collection. Parotid saliva was collected using a sterile Lashley cup, placed over the papilla of the Stensen´s duct, as well as sterile tubes and syringes for collection. All collections were followed by collection of a positive control sample where some of the sterile...... obtained parotid saliva had been exposed to the contralateral mucosal membranes. All samples parotid saliva, as well as the positive controls, were cultivated, and 10 randomly selected parotid saliva samples underwent polymerase chain reaction (PCR) analyses. RESULTS: In 33 of 40 parotid saliva samples...

  15. Studies on induced mutation of sesame male sterility

    International Nuclear Information System (INIS)

    Li Yingde; Feng Xiangyun; Zhao Yingzhong

    2001-01-01

    The dry seeds of the high yielding cultivar, Yuzhi-4, were irradiated with 300, 500 and 700 Gy of 60 Co- gamma rays. 3277 M 1 plants were harvested separately as single plants and also in bulk, by doses. In M 2 , the single plant seeds were grown in progeny rows and the bulked seeds were grown as bulks. 25 male sterile plants were screened from M 2 . 10 of the 25 male sterile plants were from the progenies of the single plant seeds and 15 were from the progenies of the bulked seeds. In further genetic research of the 25 male sterile plants in M 3 and M 4 , 6 separate genic male sterile (GMS) lines were identified. Their male sterility was stable and was controlled by a pair of alleles, male fertility being dominant to sterility. (author)

  16. Radiation sterilization of some pharmaceutical preparations and medical products

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Makhkamov, Sh.M.; Urinov, Sh.S.; Turaev, A.S.; Sultanov, M.S.; Inagomov, Kh.S.

    2006-01-01

    Full text: In connection with intensive development of pharmacology and medical techniques, use of the products contacting to blood, with the internal environment of an organism, with wound surface, with mucous membranes and skin there were high requirements to sterility of pharmaceutical preparations and medical products. Traditional methods of sterilization (heat treatment, gas processing and processing the ferry) have some restrictions in application, and not insufficient degree of sterilization required for pharmaceutical preparations and medical products. Thermal processing can lead to degradation of structure (medicine), mechanical changes and loss of medical properties. Besides, it is impossible to carry out sterilization of many pharmaceutical preparations by a method of heat treatment. Sterilization of products in packing is very complicated, because sterilization temperature of packing and a product is different. Gas processing is basically applied to sterilization of medical products (syringes, bandage, cotton wools, etc.). However, the degree of sterility is low, because of rather low ability and heterogeneity of sterilizing substance. Sterilization in packing represents special difficulty and demands additional charges related with delivery of the purified gas from abroad. Last years alongside with known technological methods of sterilization of medical products and pharmaceutical preparations radiating methods of processing have found wide application. Use of electronic bunches with the moderate energy and various isotopes became a basis for formation and development of a new direction in the medicine, called by 'radiation sterilization'. The radiation technology is highly harmless and economic, not polluting substance and surrounding space. Unlike the specified traditional methods, radiating processing of products by the isotope 60 Co, radiating the gamma quantum, has unique opportunities - high penetrability in substance, providing uniformity of

  17. A see-saw mechanism with light sterile neutrinos

    International Nuclear Information System (INIS)

    McKellar, B.H.J.; Garbutt, M.; Stephenson, G.J.; Goldman, T.

    2001-01-01

    The usual see-saw mechanism for the generation of light neutrino masses is based on the assumption that all of the flavours of right-handed (more properly, sterile) neutrinos are heavy. If the sterile Majorana mass matrix is singular, one or more of the sterile neutrinos will have zero mass before mixing with the active (left-handed) neutrinos and be light after that mixing is introduced In particular, a rank 1 sterile mass matrix leads naturally to two pseudo-Dirac pairs, one very light active Majorana neutrino and one heavy sterile Majorana neutrino. For any pattern of Dirac masses, there exists a region of parameter space in which the two pseudo-Dirac pairs are nearly degenerate in mass. This, in turn, leads to large amplitude mixing of active states as well as mixing into sterile states

  18. Acute cardiovascular toxicity of sterilizers, PHMG, and PGH: severe inflammation in human cells and heart failure in zebrafish.

    Science.gov (United States)

    Kim, Jae-Yong; Kim, Hak Hyeon; Cho, Kyung-Hyun

    2013-06-01

    In 2011, dozens of children and pregnant women in Korea died by exposure to sterilizer for household humidifier, such as Oxy(®) and Cefu(®). Until now, however, it remains unknown how the sterilizer affect the human health to cause the acute deaths. To find its toxicity for organ, we investigated the putative toxicity of the sterilizer in the cardiovascular system. The sterilizers, polyhexamethylene guanidine phosphate (PHMG, Cefu(®)), and oligo-[2-(2-ethoxy)-ethoxyethyl)-guanidinium-chloride (PGH, Oxy(®)) were treated to human lipoproteins, macrophages, and dermal fibroblast cells. The PGH and PHMG at normal dosages caused severe atherogenic process in human macrophages, cytotoxic effect, and aging in human dermal cell. Zebrafish embryos, which were exposed to the sterilizer, showed early death with acute inflammation and attenuated developmental speed. All zebrafish exposed to the working concentration of PHMG (final 0.3 %) and PGH (final 10 mM) died within 70 min and displayed acute increases in serum triacylglycerol level and fatty liver induction. The dead zebrafish showed severe accumulation of fibrous collagen in the bulbous artery of the heart with elevation of reactive oxygen species. In conclusion, the sterilizers showed acute toxic effect in blood circulation system, causing by severe inflammation, atherogenesis, and aging, with embryo toxicity.

  19. Efficient transformation of Kalanchoe blossfeldiana and production of male-sterile plants by engineered anther ablation.

    Science.gov (United States)

    García-Sogo, Begoña; Pineda, Benito; Castelblanque, Lourdes; Antón, Teresa; Medina, Mónica; Roque, Edelín; Torresi, Claudia; Beltrán, José Pío; Moreno, Vicente; Cañas, Luis Antonio

    2010-01-01

    Engineered male sterility in ornamental plants has many applications such as facilitate hybrid seed production, eliminate pollen allergens, reduce the need for deadheading to extend the flowering period, redirect resources from seeds to vegetative growth, increase flower longevity and prevent gene flow between genetically modified and related native plants. We have developed a reliable and efficient Agrobacterium-mediated protocol for the genetic transformation of different Kalanchoe blossfeldiana commercial cultivars. Transformation efficiency for cv. 'Hillary' was 55.3% whereas that of cv. 'Tenorio' reached 75.8%. Selection was carried out with the nptII gene and increasing the kanamycin concentration from 25 to 100 mg l(-1) allowed to reduced escapes from 50 to 60% to virtually 0%. This method was used to produce male-sterile plants through engineered anther ablation. In our approach, we tested a male sterility chimaeric gene construct (PsEND1::barnase) to evaluate its effectiveness and effect on phenotype. No significant differences were found in the growth patterns between the transgenic lines and the wild-type plants. No viable pollen grains were observed in the ablated anthers of any of the lines carrying the PsEND1::barnase construct, indicating that the male sterility was complete. In addition, seed set was completely abolished in all the transgenic plants obtained. Our engineered male-sterile approach could be used, alone or in combination with a female-sterility system, to reduce the invasive potential of new ornamentals, which has become an important environmental problem in many countries.

  20. Gene, protein, and network of male sterility in rice

    OpenAIRE

    Wang, Kun; Peng, Xiaojue; Ji, Yanxiao; Yang, Pingfang; Zhu, Yingguo; Li, Shaoqing

    2013-01-01

    Rice is one of the most important model crop plants whose heterosis has been well-exploited in commercial hybrid seed production via a variety of types of male-sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and prot...

  1. Search for sterile neutrinos at RENO

    Science.gov (United States)

    Yeo, In Sung; RENO Collaboration

    2017-09-01

    The RENO experiment was designed to measure a neutrino mixing angle, θ13, by detecting electron antineutrinos emitted from the Hanbit nuclear reactors in Korea, and succeeded to measure θ13 from the disappearance mode in three neutrino frame. We investigate the possibility of sterile neutrinos existence at RENO experiment and compare data with Monte Carlo generated in four neutrino frame. In this talk, we present some recent results using chi-square analysis method. The probability deficit curve as a function of an effective baseline and the excluded contour plot in sin2(2 θ14) - Δ(m41)2 space will be shown.

  2. Basic radiation sterilization properties of packaging materials

    International Nuclear Information System (INIS)

    Zouharova, A.; Kolarova, J.; Olbrichova, D.

    1984-01-01

    The foils of various materials were irradiated with 60 Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.)

  3. Environment and the sterile insect technique

    International Nuclear Information System (INIS)

    Nagel, P.; Peveling, R.

    2005-01-01

    The sterile insect technique (SIT) is an exceptionally promising pest control method in terms of efficacy and environmental compatibility. Assessments of environmental risks vary according to the status and origin of the target pests. The suppression or eradication of exotic pest populations with the SIT raises few environmental concerns, and these are related mainly to pre-release suppression techniques. However, the elimination of native species, or at least populations of native species, requires more detailed and complex assessments of ecological effects and consequences for biodiversity conservation. Eradication programmes provide opportunities to study these topics within the scope of both environmental impact assessments and operational monitoring programmes. (author)

  4. Proton decay and light sterile neutrinos

    Science.gov (United States)

    Helo, Juan C.; Hirsch, Martin; Ota, Toshihiko

    2018-06-01

    Within the standard model, non-renormalizable operators at dimension six ( d = 6) violate baryon and lepton number by one unit and thus lead to proton decay. Here, we point out that the proton decay mode with a charged pion and missing energy can be a characteristic signature of d = 6 operators containing a light sterile neutrino, if it is not accompanied by the standard π0 e + final state. We discuss this effect first at the level of effective operators and then provide a concrete model with new physics at the TeV scale, in which the lightness of the active neutrinos and the stability of the proton are related.

  5. Sterile searches with Liquid Argon at FNAL

    CERN Document Server

    Raselli, Gian Luca

    2017-01-01

    A new Short Baseline Neutrino (SBN) experiment is in preparation at FNAL to definitely prove or exclude the existence of non-standard neutrino oscillations into sterile states. The program foresees the deployment along the Booster Neutrino Beam (BNB) of three detectors, all based on the liquid-argon time projection chamber technique. This technology has been taken to full maturity with ICARUS T600, which will act as far detector after the completion of the overhauling at CERN and its transportation to FNAL. The program foresees the data taking for three years.

  6. Surgical sterilization of free-ranging wolves.

    OpenAIRE

    Spence, C E; Kenyon, J E; Smith, D R; Hayes, R D; Baer, A M

    1999-01-01

    The objective of the study was to determine whether surgical sterilization of both males and females in wolf pairs alters basic wolf social and territorial behaviors. Wolves were located from the air by snow-tracking methods and were tranquilizer-darted from a helicopter. Surgeries were performed either in a tent at the capture site or in a heated building in a nearby village. Six vasectomies and seven uterine horn ligations were performed in January and February of 1996 and 1997. Two females...

  7. Ozone-mist spray sterilization for pest control in agricultural management

    Science.gov (United States)

    Ebihara, Kenji; Mitsugi, Fumiaki; Ikegami, Tomoaki; Nakamura, Norihito; Hashimoto, Yukio; Yamashita, Yoshitaka; Baba, Seiji; Stryczewska, Henryka D.; Pawlat, Joanna; Teii, Shinriki; Sung, Ta-Lun

    2013-02-01

    We developed a portable ozone-mist sterilization system to exterminate pests (harmful insects) in agricultural field and greenhouse. The system is composed of an ozone generator, an ozone-mist spray and a small container of ozone gas. The ozone generator can supply highly concentrated ozone using the surface dielectric barrier discharge. Ozone-mist is produced using a developed nozzle system. We studied the effects of ozone-mist spray sterilization on insects and agricultural plants. The sterilization conditions are estimated by monitoring the behavior of aphids and observing the damage of the plants. It was shown that aphids were exterminated in 30 s without noticeable damages of the plant leaves. The reactive radicals with strong oxidation potential such as hydroxyl radical (*OH), hydroperoxide radical (*HO2), the superoxide ion radical (*O2‒) and ozonide radical ion (*O3‒) can increase the sterilization rate for aphids. Contribution to the Topical Issue "13th International Symposium on High Pressure Low Temperature Plasma Chemistry (Hakone XIII)", Edited by Nicolas Gherardi, Henryca Danuta Stryczewska and Yvan Ségui.

  8. Electron sterilization validation techniques using the controlled depth of sterilization process

    International Nuclear Information System (INIS)

    Cleghorn, D.A.; Nablo, S.V.

    1990-01-01

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and X-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating X-ray dose ratios are possible for the application of the technique. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed. (author)

  9. American Sterilization: The Racist Justifications for Sterilization in the United States

    OpenAIRE

    Trevor Price

    2016-01-01

    An investigative analysis into anthropometrics, sterilization, eugenics, and other forms of scientific racism used to justify white supremacy and racial thought in the 19th and 20th centuries in the United States. The Tuskegee syphilis study, Darwinistic ideals, and neo-Lamarckian thoughts are critically analyzed as justifications for institutional racism.

  10. International standard (ISO) of radiation sterilization and issues in the sterilization dose setting

    International Nuclear Information System (INIS)

    Takehisa, Masaaki

    1995-01-01

    The ISO dose setting method 1 uses bioburden and verification by sublethal sterility test. Current devices produced in clean environmental have low bioburden, however, sensitivity of verification test declines at low bioburden. Validation of verification in this region should be further studied. A dose setting using D 10 of bioburden isolates should be reevaluated and included in the ISO. (author)

  11. Dark matter relic abundance and light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi-Lei [Center for High Energy Physics,Peking University, Beijing 100871 (China); Zhu, Shou-hua [Center for High Energy Physics,Peking University, Beijing 100871 (China); Institute of Theoretical Physics & State Key Laboratory of Nuclear Physics and Technology,Peking University, Beijing 100871 (China); Collaborative Innovation Center of Quantum Matter,Beijing 100871 (China)

    2017-01-09

    In this paper, we calculate the relic abundance of the dark matter particles when they can annihilate into sterile neutrinos with the mass ≲100 GeV in a simple model. Unlike the usual standard calculations, the sterile neutrino may fall out of the thermal equilibrium with the thermal bath before the dark matter freezes out. In such a case, if the Yukawa coupling y{sub N} between the Higgs and the sterile neutrino is small, this process gives rise to a larger Ω{sub DM}h{sup 2} so we need a larger coupling between the dark matter and the sterile neutrino for a correct relic abundance.

  12. Induction of male sterility in rice using chemical mutagens

    Energy Technology Data Exchange (ETDEWEB)

    Minocha, J L; Gupta, R K [Department of Genetics, Punjab Agricultural University, Ludhiana (India)

    1988-07-01

    Full text: To diversify the sources of cytoplasmic male sterility for hybrid seed production in rice (Oryza sativa L.) attempts were made to induce this character in a popular indica cultivar PR 106 through chemical mutagens. Seeds were treated with 0.4% ethidium bromide (EB) for 24 or 48h at 10 deg. C, with 0.4% ethyl methanesulphonate (EMS) for 24 or 48h at 10 deg. C for 16 hr at 20 deg. C or with 0.2% streptomycin sulphate (SM) for 24 or 48 hr at 10 deg. C. In M{sub 2} male sterile plants were detected in eleven different progenies, one from SM treatment and the remaining from EMS treatments. All the sterile plants had 100% non-stainable aborted pollen. Seed set upon open-pollination of the male sterile plants with the variety PR 106 ranged from 0.03 to 4.93 per cent whereas no seed formed in bagged panicles. In M{sub 3}, open-pollinated progenies of the male sterile plants and their fertile sibs were further studied. Two progenies segregated for male sterility, all others had only fertile plants. In one of the segregating progenies, five out of six and in the other nine out of fourteen plants were male sterile. The progenies of fertile sibs did not have any male sterile plant. The results indicate that sterility of cytoplasmic type has been induced by EMS. The parental variety PR 106 acts as the maintainer. (author)

  13. Genetic expression of induced rice sterility under alien-cytoplasm

    International Nuclear Information System (INIS)

    Wang Naiyuan; Cai Zhijun; Liang Kangjing; Li Yu

    2005-01-01

    Rice restorer lines were treated with 60 Co γ-ray and 4 male sterile mutants obtained with the fertility of controlled by 4 non-allelic recessive genes, respectively. Sixty combinations were made by using male sterile plants/fertile plants as male parents, and 15 different cytoplasmic substitution lines of the same cell nucleus as female parents. The result showed that F 1 spikelets were normal and fertile, and different numbers of male sterile plants were segregated in F 2 . Complete fertility genotype was not found among interactions between induced male sterile genes and alien-cytoplasms. (authors)

  14. Protozoa and their bacterial prey colonize sterile soil fast

    DEFF Research Database (Denmark)

    Altenburger, Andreas; Ekelund, Flemming; Jacobsen, Carsten Suhr

    2010-01-01

    We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them to the at......We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them...

  15. Sterilization of the artificial blood circulation apparatus with ozone

    Energy Technology Data Exchange (ETDEWEB)

    Pisarevskii, A A; Korukhov, N I.U.; Brazhnikov, E M; Konstantinova, M L; Razumovskii, S D

    1982-01-01

    Presented in this paper is the sterilization method of the assisted circulation unit. The method has been approved by stand testing and then applied for sterilizing the unit Ae, yeK-5 m when experimental implanting artificial heart. According to the method, ozone in concentration of 5 x 10(-3) moles/1 and with flow rate of 0,5 1/min is passed through an internal circuit of the unit during I h and 15 min. Control wash-out samples from lines have demonstrated complete sterility of the internal circuit. The method makes the sterilization process of such units much easier and may be recommended for clinical application.

  16. Induction of male sterility in rice using chemical mutagens

    International Nuclear Information System (INIS)

    Minocha, J.L.; Gupta, R.K.

    1988-01-01

    Full text: To diversify the sources of cytoplasmic male sterility for hybrid seed production in rice (Oryza sativa L.) attempts were made to induce this character in a popular indica cultivar PR 106 through chemical mutagens. Seeds were treated with 0.4% ethidium bromide (EB) for 24 or 48h at 10 deg. C, with 0.4% ethyl methanesulphonate (EMS) for 24 or 48h at 10 deg. C for 16 hr at 20 deg. C or with 0.2% streptomycin sulphate (SM) for 24 or 48 hr at 10 deg. C. In M 2 male sterile plants were detected in eleven different progenies, one from SM treatment and the remaining from EMS treatments. All the sterile plants had 100% non-stainable aborted pollen. Seed set upon open-pollination of the male sterile plants with the variety PR 106 ranged from 0.03 to 4.93 per cent whereas no seed formed in bagged panicles. In M 3 , open-pollinated progenies of the male sterile plants and their fertile sibs were further studied. Two progenies segregated for male sterility, all others had only fertile plants. In one of the segregating progenies, five out of six and in the other nine out of fourteen plants were male sterile. The progenies of fertile sibs did not have any male sterile plant. The results indicate that sterility of cytoplasmic type has been induced by EMS. The parental variety PR 106 acts as the maintainer. (author)

  17. Comparative mating and reproductive performance of radiation sterilized and radiation induced F1 sterile males of Earias vittella (Fabricius)

    International Nuclear Information System (INIS)

    Shantharam, K.; Tamhankar, A.J.; Harwalkar, M.R.

    1995-01-01

    Studies were conducted on mating behaviour and reproductive performance of a) Earias vittella (F.) males rendered sterile by exposing them to 300 Gy gamma rays and b) F 1 sterile males obtained by exposing parent male to 100 Gy gamma rays. For the study, males were allowed only one mating with a normal female. Results revealed that premating period, period in copula and per cent insects mating were not adversely affected in case of both types of sterile males and fecundity also remained unaffected. However, in both types of sterile males, incidence of spermatophore transfer without sperm was very large and such an occurrence (including reduced spermatophore transfer) was significantly higher in case of radiation sterilized males compared to the F 1 sterile males. Inability to produce and transfer spermatophore and/or sperm appeared to be a major cause behind the reduced mating competitiveness of both types of males. (author). 22 refs., 2 tabs

  18. Why are rates of sterilization in decline? A pilot study designed to explore reasons for declining female sterilization in Scotland.

    Science.gov (United States)

    Chen, Zhong E; Glasier, Anna; Warner, Pamela

    2008-10-01

    In the last decade, female sterilization had been in decline throughout the UK. It is not clear whether fewer women are requesting sterilization or whether the universal enthusiasm for long-acting reversible methods is leading health professionals to discourage women from being sterilized. Since correct and consistent use of alternative, reversible contraceptive methods depends somewhat on their acceptability, it is important to determine whether women are being refused sterilization or whether they are freely choosing other methods. This study aims to explore whether female sterilization is being widely considered as a contraceptive method, the reasons for choosing or rejecting it, and whether women are being discouraged by health professionals from being sterilized. A self-completed questionnaire survey among 205 women aged 30 to 50 years who felt that their family was complete attending a family planning clinic in Scotland. Of the 203 women included in the study, 151 (74.4%) had heard of female sterilization, 90 had discussed it with someone (60%) and 87 (58%) had considered it as a contraceptive option. Of the 56 women who consulted their family doctor about sterilization, almost half (27; 48%) were not referred to a hospital and fewer than one (17, 30.4%) in three of them was eventually sterilized or had arrangements in place to get it done. Free-text comments from the women revealed a variety of reasons for not choosing female sterilization and suggested that some women are being deterred from sterilization. The study suggests that some women are being actively encouraged by health professionals to use long-acting reversible contraceptive methods and discouraged from choosing sterilization. However, other women recognize for themselves the wisdom of keeping their fertility options open.

  19. Sterilization Monitoring management of the integration of the operating room with CSSD

    Directory of Open Access Journals (Sweden)

    Shu-yan XIA

    2014-08-01

    Full Text Available Objective: Explore the Sterilization Monitoring management of the integration of the operating room with CSSD. Methods: Compare sterilization process monitoring with biological monitoring and chemical monitoring. Results: The management in Biological monitoring, chemical monitoring and sterilization process monitoring is crucial. Conclusion: Sterilization monitoring is to ensure the safe use of sterile goods so as to protect the safety of surgical patients.

  20. Sterilization of biological tissues with ionizing radiation

    International Nuclear Information System (INIS)

    Reyes F, M.L.; Martinez P, M.E.; Luna Z, D.

    1997-01-01

    On June 1994, the National Institute of Nuclear Research (ININ) and the South Central Hospital for High Specialty of PEMEX (HCSAE) began a joint work with the finality to obtain radio sterilized amniotic membranes for to be used as cover (biological bandage) in burnt patients. Subsequently the Chemistry Faculty of UNAM and the National Institute of Cardiology began to collaborate this last with interest on cardiac valves for graft. Starting from 1997, the International Atomic Energy Agency (IAEA) supports this project (MEX/7/008) whose main objective is to set up the basis to establish in Mexico a Radio sterilized Tissue Bank (amniotic membranes, skin, bones, tendons, cardiac valves, etc.) to be used with therapeutic purposes (grafts). The IAEA support has consisted in the equipment acquisition which is fundamental for the Tissue Bank performance such as an experimental irradiator, laminar flow bell, lyophilizer, vacuum sealer and special knives for tissues. Also visits to Mexico of experts have been authorized with the aim of advising to the personnel which participate in the project and scientific visits of this personnel to another tissue banks (Sri Lanka and Argentine). The establishment in Mexico of a Tissue bank will be a great benefit because it will have availability of distinct tissues for grafts and it will reduce the synthetic materials importation which is very expensive. (Author)

  1. Radiation sterilization of polymeric implant materials

    International Nuclear Information System (INIS)

    Bruck, S.D.; Mueller, E.P.

    1988-01-01

    High-energy irradiation sterilization of medical devices and implants composed of polymeric biomaterials that are in contact with tissue and/or blood, may adversely affect their long-term mechanical and/or biological performance (tissue and/or blood compatibility). Since many polymeric implants may contain trace quantities of catalysts and/or other additives, the effect of high-energy radiation on these additives, and possible synergistic effects with the polymer chains under the influence of high-energy radiation, must be considered. It is essential to indicate whether polymeric implants are used in short-term (acute) or long-term (chronic) applications. Relatively small changes in their physicochemical, mechanical, and biological properties may be tolerable in the short term, whereas similar changes may lead to catastrophic failures in long-term applications. Therefore, polymeric implants which are to be sterilized by high-energy irradiation should be carefully evaluated for long-term property changes which may be induced by the radiation

  2. Inactivation of animal and human prions by hydrogen peroxide gas plasma sterilization.

    Science.gov (United States)

    Rogez-Kreuz, C; Yousfi, R; Soufflet, C; Quadrio, I; Yan, Z-X; Huyot, V; Aubenque, C; Destrez, P; Roth, K; Roberts, C; Favero, M; Clayette, P

    2009-08-01

    Prions cause various transmissible spongiform encephalopathies. They are highly resistant to the chemical and physical decontamination and sterilization procedures routinely used in healthcare facilities. The decontamination procedures recommended for the inactivation of prions are often incompatible with the materials used in medical devices. In this study, we evaluated the use of low-temperature hydrogen peroxide gas plasma sterilization systems and other instrument-processing procedures for inactivating human and animal prions. We provide new data concerning the efficacy of hydrogen peroxide against prions from in vitro or in vivo tests, focusing on the following: the efficiency of hydrogen peroxide sterilization and possible interactions with enzymatic or alkaline detergents, differences in the efficiency of this treatment against different prion strains, and the influence of contaminating lipids. We found that gaseous hydrogen peroxide decreased the infectivity of prions and/or the level of the protease-resistant form of the prion protein on different surface materials. However, the efficiency of this treatment depended strongly on the concentration of hydrogen peroxide and the delivery system used in medical devices, because these effects were more pronounced for the new generation of Sterrad technology. The Sterrad NX sterilizer is 100% efficient (0% transmission and no protease-resistant form of the prion protein signal detected on the surface of the material for the mouse-adapted bovine spongiform encephalopathy 6PB1 strain and a variant Creutzfeldt-Jakob disease strain). Thus, gaseous or vaporized hydrogen peroxide efficiently inactivates prions on the surfaces of medical devices.

  3. Hysteroscopic sterilization of patient with intrauterine device Mirena®

    Science.gov (United States)

    Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Yatabe, Salete; Lopes, Reginaldo Guedes Coelho

    2013-01-01

    ABSTRACT Tubal sterilization is the definitive procedure most often used worldwide to control fecundity. Laparoscopic ligature is safe, but invasive and with possible surgical and anesthetic risks. The hysteroscopic approach enables tubal occlusion at outpatient's setting without the need of incisions or anesthesia. A microdevice (Essure®) is inserted directly into the tubes and its polyethelene fibers cause obstruction of tubes in about three months. During this period, it is recommended that patients continue the use of a temporary birth control method. Several women use the levonorgestrel-releasing intrauterine system, which is called in the market as Mirena®. This report evaluated the possibility of inserting Essure® without remove the intrauterine device; patient tolerance to the procedure was also assessed. The tubal device was successfully placed in the patient without the need to remove Mirena®. After three months the intrauterine device was removed with no intercurrent events. PMID:23579753

  4. Ciprofloxacin in imaging of infective versus sterile inflammation

    International Nuclear Information System (INIS)

    Gano, L.; Patricio, L.; Cantinho, G.; Pena, H.; Martins, T.; Marques, E.

    1998-01-01

    Ciprofloxacin (CIP) was labelled with 99 Tc m . The radiolabelled efficiency monitored by ITLC and HPLC was higher than 95%. The 99 Tc m -CIP complex analyzed by those systems have shown that inactive and labelled CIP exhibit different chromatographic behavior. This finding together with octanol/saline partition coefficients determination indicated that CIP and 99 Tc m -CIP correspond to different chemical structure. Biodistribution studies in inflamed mice shown that 99 Tc m -CIP is rapidly distributed after i. v. administration with a predominant renal clearance. The radioactive preparation is able to localize bacterial and sterile inflammations induced by Staphylococcus aureus, Escherichia coli and turpentine, which suggest that its accumulation is due to increased blood flow together with enhanced vascular permeability as also postulated to other non-specific radiopharmaceuticals. (author)

  5. Fieldbus: technology application in a 60Co sterilization plant

    International Nuclear Information System (INIS)

    Karam, D.; Sampa, M.H.O.; Rela, P.R.

    2000-01-01

    Process instrumentation was made by pressure signals in the 1940s. In the 1960s, 4-20 mA analogue signals were introduced. The development of digital processors in the 1970s sparked the use of computers to monitor and control instruments from a central point. In the 1980s smart sensors were developed and implemented in digital control, microprocessor environments. Fieldbus is a generic-term that describes a new digital communications network. The network is a digital, bi-directional, multidrop, serial-bus, and communications network used to link isolated field devices, such as controllers, transducers, actuators and sensors. Fieldbus technology may improve quality, reduce costs and increase efficiency because information is transmitted digitally without analog to digital or digital to analog converters, which also minimizes hardware errors. Fieldbus communication is based on two-wire communication, interconnecting all the components in the system. This paper introduces Fieldbus technology in a 60 Co sterilization plant

  6. Expression of a pathogen-induced cysteine protease (AdCP) in tapetum results in male sterility in transgenic tobacco.

    Science.gov (United States)

    Shukla, Pawan; Singh, Naveen Kumar; Kumar, Dilip; Vijayan, Sambasivam; Ahmed, Israr; Kirti, Pulugurtha Bharadwaja

    2014-06-01

    Usable male sterility systems have immense potential in developing hybrid varieties in crop plants, which can also be used as a biological safety containment to prevent horizontal transgene flow. Barnase-Barstar system developed earlier was the first approach to engineer male sterility in plants. In an analogous situation, we have evolved a system of inducing pollen abortion and male sterility in transgenic tobacco by expressing a plant gene coding for a protein with known developmental function in contrast to the Barnase-Barstar system, which deploys genes of prokaryotic origin, i.e., from Bacillus amyloliquefaciens. We have used a plant pathogen-induced gene, cysteine protease for inducing male sterility. This gene was identified in the wild peanut, Arachis diogoi differentially expressed when it was challenged with the late leaf spot pathogen, Phaeoisariopsis personata. Arachis diogoi cysteine protease (AdCP) was expressed under the strong tapetum-specific promoter (TA29) and tobacco transformants were generated. Morphological and histological analysis of AdCP transgenic plants showed ablated tapetum and complete pollen abortion in three transgenic lines. Furthermore, transcript analysis displayed the expression of cysteine protease in these male sterile lines and the expression of the protein was identified in western blot analysis using its polyclonal antibody raised in the rabbit system.

  7. Sterilization of fruit flies (Diptera: Tephritidae) with X-rays for sterile insect technique programs

    International Nuclear Information System (INIS)

    Mastrangelo, Thiago de Araujo

    2009-01-01

    Recent fear of acts of terrorism provoked an increase of delays and denials in the shipment of radioisotopes. This truly represented a menace to sterile insect production projects around the world. In order to validate the use of a new kind of low-energy Xray irradiator, a series of radiobiological studies on Ceratitis capitata (tsl-VIENNA 8 strain) (Wied., 1824) (Diptera: Tephritidae) and an Argentinean strain of Anastrepha fraterculus (Wied., 1830) (Diptera: Tephritidae) were carried out, also comparing biological effectiveness between X-rays and traditional γ radiation from 60 Co. Pupae 48- 24 h before adult emergence of C. capitata males and both sexes of A. fraterculus were irradiated with doses ranging from 15 to 120 Gy and 10 to 70 Gy respectively. Doses that induce 50, 90 and 99% of sterility were estimated and the hypothesis of Parallelism for the Probit equations was tested. Doses of 82.7 Gy of X-rays and 128.2 Gy of γ rays (thus, a RBE∼1.5) induced 99% sterility on medfly males. The fertility of A. fraterculus fertile females crossed with 41 Gy of X-rays and 62.7 Gy of γ rays decreased in 99% comparing with the control group (RBE∼1.5). 99% sterility of A. fraterculus irradiated females was achieved with 60-80 Gy (RBE∼0.7). The standard quality control parameters of fecundity, adult emergence, fliers and survival were not significantly affected by the two types of radiation (RBE∼1) either for medfly or A. fraterculus (p>0.01), being averages in conformity with the values required by FAO/IAEA/USDA. Only fecundity of irradiated A. fraterculus females was severely reduced with increasing doses and no egg was laid at 70 Gy of both radiations. There were no significant differences between X-rays and γ rays regarding mating indices (RSI for medfly, RII, ISI, MRPI and FRPI for A. fraterculus) (p>0.05), what indicated more random matings for fertile and sterile insects. The results demonstrated that no significant difference in biological

  8. 9. School of radiation sterilization and hygienization - Lectures

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9 School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  9. Female sterilization by tubal ligation at caesarean section in Makurdi ...

    African Journals Online (AJOL)

    Background: Female sterilization is an important tool in reducing unplanned pregnancy and maternal mortality in our environment. The aim of this study was to determine the incidence, sociodemographic characteristics, technique, effectiveness and complications associated with female sterilization by bilateral tubal ligation ...

  10. Objections to tubal sterilization: what reversibility can and cannot overcome.

    Science.gov (United States)

    Shain, R N

    1980-09-01

    In a study of 1074 women, 696 and 338 subjects would not seriously consider permanent and hypothetically reversible sterilization, respectively; they were asked to explain their feelings. The reason accounting for most objections to permanent sterilization (65%) was irreversibility and of the subjects who would not consider reversible sterilization or were unsure, 42.7% attributed their principal objection to unnecessary surgery, a factor at least currently intrinsic to the procedure and not readily overcome by education. Many of the remaining objections to both permanent and reversible sterilization may be amenable to change either through education or financial subsidies. In response to a question concerning female attractiveness subsequent to permanent sterilization, 3% of the sample felt attractiveness would decrease and 17.5% were unsure of the surgery's effect. Unsure responses were largely negative in character. This issue is important because of its relationship to intention to undergo sterilization. Upon consideration of reversible sterilization, negative and unsure responses significantly declined, even on the part of those women whose friends have had a poor experience with currently available procedures. Thus, whereas the option of reversibility cannot overcome objections to surgery, it does overcome those regarding permanency; moreover, the "temporary" character it bestows upon surgical sterilization appears to help certain individuals overcome their fears of losing their physical appeal as a result of such procedures.

  11. 9. School of radiation sterilization and hygienization - Presentations

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9. School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  12. Comparison of Sterile and Clean Dressing Techniques in Post ...

    African Journals Online (AJOL)

    Comparison of Sterile and Clean Dressing Techniques in Post-operative Surgical Wound Infection in a Chinese Healthcare Facility. ... of sterile and clean dressing techniques on wound management in a Chinese hospital, and to compare their impact on wound healing and the cost of the dressing materials with respect to ...

  13. Assessment of Non-Sterile Pharmaceutical Compounding Practices ...

    African Journals Online (AJOL)

    A descriptive cross-sectional survey was conducted to assess the practices of non-sterile pharmaceutical compounding in selected 42 community and 3 hospital pharmacies in Addis Ababa, Ethiopia from 01 April, 2016 to 15 May, 2016. The study revealed that the most commonly prescribed and compounded non-sterile ...

  14. Thermalisation of light sterile neutrinos in the early universe

    DEFF Research Database (Denmark)

    Hannestad, Steen; Tamborra, Irene; Tram, Thomas

    2012-01-01

    on the current cosmological data have been derived using simplified assumptions about thermalisation of the sterile neutrino at the Big Bang Nucleosynthesis (BBN) epoch. These assumptions are not necessarily justified and here we solve the full quantum kinetic equations in the (1 active + 1 sterile) scenario...

  15. Surface sterilization method for reducing microbial contamination of ...

    African Journals Online (AJOL)

    An effective disinfection method for strawberry (Fragaria x ananassa Duch.) cv. Senga Sengana micropropagation using runner tips and nodal segments as explants was developed. The explants were surface sterilized with different sterilants for different durations. The present studies on the effect of different regimes of ...

  16. 42 CFR 50.207 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207...

  17. Efficacy of gamma sterilization technique for biofertilizer carrier production

    International Nuclear Information System (INIS)

    Rallos, Roland V.; Rivera, Faye G.; Anarna, Julie A.; Rojales, Jacqueline S.

    2013-01-01

    Th use of gamma irradiation as sterilization technique for biofertilizer carrier is very efficient and practical especially in large scale production. The results of this study on the efficacy of gamma sterilization justify research on the effects of established doses of gamma irradiation on the physico-chemical properties of the clay-charcoal mixture

  18. The context and limitations of female sterilization services in Pakistan.

    Science.gov (United States)

    Khan, Adnan Ahmad; Khan, Ayesha; Abbas, Khadija; Tirmizi, Syed Farhan Ali; ul Islam, Zia

    2013-04-01

    Female sterilization has long been the most popular method of family planning (FP) in Pakistan, and yet most public health experts feel it contributes little to controlling family size or to population welfare. We used Pakistan Demographic Health Survey (PDHS) data to understand the role female sterilization plays in the overall context of FP in Pakistan. We performed a secondary analysis of data from the PDHS 1990-1 and 2006-7 to study factors that lead to sterilization and trends in the use of the procedure. In addition, census data were multiplied by proportions from PDHS data to estimate the number of women availing sterilization services. Around 1.9 million women in Pakistan are currently sterilized--up from 0.55 million in 1990-1, and around 173,867 undergo the procedure, annually. Women usually receive sterilization after 30 years of age (mean = 39) and after six children. The probability of sterilization increases with age, family size, and urban residence, and is unaffected by poverty, province of residence, or the woman or her husband's education. Most sterilizationis conducted in public sector facilities. Sterilization in Pakistan may be common, but occurs too late to have any significant effect on family size or benefit public health. Future avenues to make this option more useful to women and society would be to improve the repertoire and access and quality of FP services that are available, and to address governance issues that limit the performance and utility of government facilities.

  19. Nuclear-Cytoplasmic male-sterility in diploid dandelions

    NARCIS (Netherlands)

    van der Hulst, R.G.M.; Meirmans, P.; van Tienderen, P.H.; Van Damme, J.M.M.

    2004-01-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for

  20. Nuclear-cytoplasmic male-sterility in diploid dandelions

    NARCIS (Netherlands)

    van der Hulst, R.G.M.; Meirmans, P.G.; van Tienderen, P.H.; van Damme, J.M.M.

    2004-01-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for male

  1. Cleaning, disinfection and sterilization of surface prion contamination.

    Science.gov (United States)

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. [Determinants of sterilization among married couples in Korea].

    Science.gov (United States)

    Kim, Ju Hee; Chung, Woojin; Lee, Sunmi; Suh, Moonhee; Kang, Dae Ryong

    2007-11-01

    The purpose of this study was to examine the determinants of sterilization in South Korea. This study was based on the data from the Korea National Fertility Survey carried out in the year 2000 by the Korea Institute of Health and Social Affairs. The subjects of the analysis were 4,604 women and their husbands who were in their first marriage, in the age group of 15-49 years. The data were analyzed by multiple logistic regression analysis. Consistent with the findings of previous studies, the woman's age and the number of total children increased the likelihood of sterilization. In addition, the year of marriage had a strong positive association with sterilization. Interestingly, the number of surviving sons tended to increase the likelihood of sterilization, whereas the woman's education level and age at the time of marriage showed a negative association with sterilization. Religion, place of residence, son preference, and the husband's education level, age and type of occupation were not significant determinants of sterilization. The sex of previous children and lower level of education are distinct determinants of sterilization among women in South Korea. More studies are needed in order to determine the associations between sterilization rate and decreased fertility.

  3. History of the sterile insect technique

    International Nuclear Information System (INIS)

    Klassen, W.; Curtis, C.F.

    2005-01-01

    During the 1930s and 1940s the idea of releasing insects of pest species to introduce sterility (sterile insect technique or SIT) into wild populations, and thus control them, was independently conceived in three extremely diverse intellectual environments. The key researchers were A. S. Serebrovskii at Moscow State University, F. L. Vanderplank at a tsetse field research station in rural Tanganyika (now Tanzania), and E. F. Knipling of the United States Department of Agriculture. Serebrovskii's work on chromosomal translocations for pest population suppression could not succeed in the catastrophic conditions in the USSR during World War II, after which he died. Vanderplank used hybrid sterility to suppress a tsetse population in a large field experiment, but lacked the resources to develop this method further. Knipling and his team exploited H. J. Muller's discovery that ionizing radiation can induce dominant lethal mutations, and after World War II this approach was applied on an area-wide basis to eradicate the New World screwworm Cochliomyia hominivorax (Coquerel) in the USA, Mexico, and Central America. Since then very effective programmes integrating the SIT have been mounted against tropical fruit flies, some species of tsetse flies Glossina spp., the pink bollworm Pectinophora gossypiella (Saunders), and the codling moth Cydia pomonella (L.). In non-isolated onion fields in the Netherlands, the onion maggot Delia antiqua (Meigen) has since 1981 been suppressed by the SIT. In the 1970s there was much research conducted on mosquito SIT, which then went into 'eclipse', but now appears to be reviving. Development of the SIT for use against the boll weevil Anthonomus grandis grandis Boheman and the gypsy moth Lymantria dispar (L.) has ended, but it is in progress for two sweetpotato weevil species, Cylas formicarius (F.) and Euscepes postfasciatus (Fairmaire), the false codling moth Cryptophlebia leucotreta (Meyrick), the carob moth Ectomyelois ceratoniae

  4. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Krishnan, Vijaya

    2004-01-01

    Full Text Available EnglishPrior to early 1970s, traditional methods were the principal means ofcontrolling the number and spacing of births. Today, an estimated 57 per cent of the world's marriedwomen use contraceptives and half use modern methods such as medical sterilizations. Recent statisticssuggest that Canada has the highest sterilization rate in the Western world. This paper presentsfindings of research examining sterilization trends in Canada with respect to changing patterns in theuse of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligationand an increase in the use of hysterectomy over the period 1984-1995. Less educated women are morelikely to be in the forefront of modern methdos of contraception.FrenchAvant les années 1970, les méthodes traditionnelles représentaient le principalmoyen de contrôler et d’espacer le nombre de naissances. De nos jours, onestime que 57 pour cent des femmes mariées dans le monde entier utilisent unmoyen contraceptif et la moitié utilise des méthodes modernes telles que lastérilisation. Les dernières statistiques indiquent que le Canada compte le tauxde stérilisations le plus élevé dans le monde occidental. Cet article présente lesconclusions de recherches portant sur les tendances en matière de stérilisation auCanada en ce qui concerne les modèles changeants d’utilisation de moyens decontraception modernes et ce, à partir de données de l’Enquête canadienne sur lafécondité de 1984 et de l’Enquête sociale générale (ESG de 1995. La principaleconclusion qui en est ressortie est une réduction de la ligature des trompes etune augmentation du nombre d’hystérectomies de 1984 à 1995. Les femmesmoins éduquées sont plus portées à se trouver au premier plan des méthodes decontraception modernes.

  5. Portable Chemical Sterilizer for Microbial Decontamination of Surgical Instruments, Fruits and Vegetables, and Field Feeding Equipment

    National Research Council Canada - National Science Library

    Doona, C. J; Feeherry, F. E; Kustin, K; Curtin, M. A; Baer, D. G

    2006-01-01

    The Portable Chemical Sterilizer (PCS) is a revolutionary biomedical sterilization technology that provides the capability for portable, power-free, point-of-use sterilization to meet the Army's Far-Forward Surgical Teams (FSTs...

  6. The causes of genetic male sterility in 3 soybaen lines.

    Science.gov (United States)

    Rubaihayo, P R; Gumisiriza, G

    1978-11-01

    The cause of male sterility in 3 soybean lines, TGM 103-1, N-69-2774 and TGM 242-4 was studied. In TGM 103-1, which was both male and female sterile, two different abnormalities were associated with sterility. Precocious movement of a few chromosomes at the metaphase I stage resulted into the production of non-functional pollen while cells which underwent apparent normal meiotic division had disintergration of the tapetal cell wall immediately after the free microspore stage leading to the starvation and subsequent death of the developing microspores. In lines N-69-2774 and TGM 242-4, both of which were partially sterile, male sterility resulted from a failure of cytokinesis after the telophase II stage. Meiosis proceeded normally but the 4 microspores after telophase II failed to separate into pollen grains and degenerated thereafter.

  7. Post-sterilization autonomy among young mothers in South India.

    Science.gov (United States)

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  8. Genetic architecture of hybrid male sterility in Drosophila: analysis of intraspecies variation for interspecies isolation.

    Directory of Open Access Journals (Sweden)

    Laura K Reed

    Full Text Available BACKGROUND: The genetic basis of postzygotic isolation is a central puzzle in evolutionary biology. Evolutionary forces causing hybrid sterility or inviability act on the responsible genes while they still are polymorphic, thus we have to study these traits as they arise, before isolation is complete. METHODOLOGY/PRINCIPAL FINDINGS: Isofemale strains of D. mojavensis vary significantly in their production of sterile F(1 sons when females are crossed to D. arizonae males. We took advantage of the intraspecific polymorphism, in a novel design, to perform quantitative trait locus (QTL mapping analyses directly on F(1 hybrid male sterility itself. We found that the genetic architecture of the polymorphism for hybrid male sterility (HMS in the F(1 is complex, involving multiple QTL, epistasis, and cytoplasmic effects. CONCLUSIONS/SIGNIFICANCE: The role of extensive intraspecific polymorphism, multiple QTL, and epistatic interactions in HMS in this young species pair shows that HMS is arising as a complex trait in this system. Directional selection alone would be unlikely to maintain polymorphism at multiple loci, thus we hypothesize that directional selection is unlikely to be the only evolutionary force influencing postzygotic isolation.

  9. Surgical infection in a videolaparoscopic cholecystectomy when using peracetic acid for the sterilization of instruments.

    Science.gov (United States)

    de Melo, Edluza Maria Viana Bezerra; Leão, Cristiano de Souza; Andreto, Luciana Marques; de Mello, Maria Júlia Gonçalves

    2013-01-01

    To determine the frequency of surgical site infection in patients undergoing laparoscopic cholecystectomy with instruments sterilized by peracetic acid. We conducted a retrospective, cohort, descriptive, cross-sectional study. Peracetic acid has been used for sterilization following the protocol recommended by the manufacturer. We observed the criteria and indicators of process and structure for preventing surgical site infection pre and intraoperatively. For epidemiological surveillance, outpatient visits were scheduled for the 15th and between the 30th and 45th days after discharge. Among the 247 patients, there were two cases of surgical site infection (0.8%). One patient was readmitted to systemic antibiotic therapy and percutaneous puncture; in the other the infection was superficial and followed at the clinic. Ethical issues prevent the conduction of a prospective study because of peracetic acid have been banned for the sterilization of instruments that penetrate organs and cavities. Nevertheless, these results encourage prospective case-control studies comparing its use (historical control) with ethylene oxide sterilization.

  10. Improving hybrid seed production in corn with glyphosate-mediated male sterility.

    Science.gov (United States)

    Feng, Paul C C; Qi, Youlin; Chiu, Tommy; Stoecker, Martin A; Schuster, Christopher L; Johnson, Scott C; Fonseca, Augustine E; Huang, Jintai

    2014-02-01

    Hybrid corn varieties exhibit benefits associated with heterosis and account for most of the corn acreage in the USA. Hybrid seed corn is produced by crossing a female parent which is male-sterile and therefore incapable of self-pollination with a male parent as the pollen donor. The majority of hybrid seed corn is produced by mechanical detasseling which involves physically removing the tassel, a process that is laborious and costly. Glyphosate-resistant corn was developed via expression of a glyphosate insensitive 5-enolpyruvyl-shikimate 3-phosphate synthase enzyme (CP4-EPSPS). Experimentation with molecular expression elements resulted in selective reduction of CP4-EPSPS expression in male reproductive tissues. The resulting plant demonstrated sterile tassel following glyphosate application with little to no injury to the rest of the plant. Using (14)C-glyphosate as a marker, we also examined the translocation of glyphosate to the tassel via spray application in a track sprayer to simulate field application. The results allowed optimization of spray parameters such as dose, spray timing and target to maximize tassel delivery of glyphosate for efficient sterilization. The Roundup hybridization system (RHS) is a novel process for hybrid seed production based on glyphosate-mediated male sterility. RHS replaces mechanical detasseling with glyphosate spray and greatly simplifies the process of hybrid seed corn production. © 2013 Society of Chemical Industry.

  11. Genetic architecture of hybrid male sterility in Drosophila: analysis of intraspecies variation for interspecies isolation.

    Science.gov (United States)

    Reed, Laura K; LaFlamme, Brooke A; Markow, Therese A

    2008-08-27

    The genetic basis of postzygotic isolation is a central puzzle in evolutionary biology. Evolutionary forces causing hybrid sterility or inviability act on the responsible genes while they still are polymorphic, thus we have to study these traits as they arise, before isolation is complete. Isofemale strains of D. mojavensis vary significantly in their production of sterile F(1) sons when females are crossed to D. arizonae males. We took advantage of the intraspecific polymorphism, in a novel design, to perform quantitative trait locus (QTL) mapping analyses directly on F(1) hybrid male sterility itself. We found that the genetic architecture of the polymorphism for hybrid male sterility (HMS) in the F(1) is complex, involving multiple QTL, epistasis, and cytoplasmic effects. The role of extensive intraspecific polymorphism, multiple QTL, and epistatic interactions in HMS in this young species pair shows that HMS is arising as a complex trait in this system. Directional selection alone would be unlikely to maintain polymorphism at multiple loci, thus we hypothesize that directional selection is unlikely to be the only evolutionary force influencing postzygotic isolation.

  12. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  13. Methane potential of sterilized solid slaughterhouse wastes.

    Science.gov (United States)

    Pitk, Peep; Kaparaju, Prasad; Vilu, Raivo

    2012-07-01

    The aim of the current study was to determine chemical composition and methane potential of Category 2 and 3 solid slaughterhouse wastes rendering products (SSHWRP) viz. melt, decanter sludge, meat and bone meal (MBM), technical fat and flotation sludge from wastewater treatment. Chemical analyses showed that SSHWRP were high in protein and lipids with total solids (TS) content of 96-99%. Methane yields of the SSHWRP were between 390 and 978 m(3) CH(4)/t volatile solids (VS)(added). Based on batch experiments, anaerobic digestion of SSHWRP from the dry rendering process could recover 4.6 times more primary energy than the energy required for the rendering process. Estonia has technological capacity to sterilize all the produced Category 2 and 3 solid slaughterhouse wastes (SSHW) and if separated from Category 1 animal by-products (ABP), it could be further utilized as energy rich input material for anaerobic digestion. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Pressure-assisted thermal sterilization of soup

    Science.gov (United States)

    Shibeshi, Kidane; Farid, Mohammed M.

    2010-12-01

    The overall efficiency of an existing scale-up pressure-assisted thermal sterilization (PATS) unit was investigated with regards to inactivation of Geobacillus stearothermophilus spores suspended in pumpkin soup. The PATS unit is a double pipe heat exchanger in which the soup is pumped into its inner high pressure tube and constrained by two high pressure valves, while steam is continuously passed through the annular region to heat the content. The technology is based on pressure generation by thermal expansion of the liquid in an enclosure. In this work, the addition of an air line to push the treated liquid food out of the existing PATS unit has improved the overall quality of the treated samples, as evidenced by achieving higher log reduction of the spores. Compared with thermal processing, the application of PATS shows the potential for lowering the thermal treatment temperature, offering improved food quality.

  15. Twenty years of radiation sterilization in Croatia

    Science.gov (United States)

    Ražem, Dus̆an

    2004-09-01

    The development of radiation processing in Croatia is described from its inception 20 years ago up to the present time. Annual throughputs of treated materials are given by the categories of materials and pertaining volumes. The pasteurization of hard gelatine capsules occured during the early stages, while sterilization of disposable medical supplies has been dominant in the later stages. Irradiation of foods and of cosmetics and toiletries has been a minor fraction of the total throughput. Since the recovery of everyday life and economy of the country after the war, the total throughput has increased steadily to reach 13,000 m 3 kGy in 2002, 90% of which are medical supplies. Estimates of the present maximum capacity of 30,000 m 3 kGy and of future needs indicate that the present rate of growth could be sustained for the next several years only, unless a major upgrading is undertaken. An estimate of potential future needs is made.

  16. [The psychosocial background of sterile patients].

    Science.gov (United States)

    Pusch, H H; Urdl, W; Walcher, W

    1989-01-01

    The psychosocial background of 300 childless couples from the Infertility Clinic of the Department of Gynecology and Obstetrics, University of Graz, was evaluated by means of a questionnaire and statistical analysis of data from their files. Points of special interest were problems such as interactions of the couple, motivations for the desire of children, psychosomatics, andrological investigation within the gynecological department, sexual habits and motivation and compliance concerning investigations and treatment. 72% of the questionnaires were returned. 50% of the sterile couples preferred to attend the infertility clinic together. 26% felt restrictions in their sexual behaviour due to the unrealized desire of children, 48% expected improvements in their partnership if they could have children. Compliance of male partners concerning the regular intake of prescribed medicaments was 83%, 63% accepted to stop smoking in cases of pathospermia.

  17. Informed consent needed for sterilization or research.

    Science.gov (United States)

    Barnett, B

    1998-01-01

    Informed choice involves enabling family planning clients to base their decisions about contraceptive use upon adequate information. It is a process in which clients give their permission to undergo a procedure, take a medication, or participate in a study after being fully informed. Informed consent protects an individual's freedom of choice, respects his or her autonomy, is important in both family planning programs and reproductive health research, and should always be available to clients seeking health services. Although written informed consent is not needed for most reproductive health services, it should be obtained from men and women who undergo sterilization, since that involves surgery and is considered permanent. In addition, people who volunteer to participate in contraceptive studies need to be fully informed of the risks and benefits of any new drugs or devices they receive. Volunteers should understand the potential effects of methods upon their physical health and other aspects of their lives. Ethical reviews need to be conducted before research begins.

  18. Twenty years of radiation sterilization in Croatia

    International Nuclear Information System (INIS)

    Razem, Dusan

    2004-01-01

    The development of radiation processing in Croatia is described from its inception 20 years ago up to the present time. Annual throughputs of treated materials are given by the categories of materials and pertaining volumes. The pasteurization of hard gelatine capsules occured during the early stages, while sterilization of disposable medical supplies has been dominant in the later stages. Irradiation of foods and of cosmetics and toiletries has been a minor fraction of the total throughput. Since the recovery of everyday life and economy of the country after the war, the total throughput has increased steadily to reach 13,000 m 3 kGy in 2002, 90% of which are medical supplies. Estimates of the present maximum capacity of 30,000 m 3 kGy and of future needs indicate that the present rate of growth could be sustained for the next several years only, unless a major upgrading is undertaken. An estimate of potential future needs is made

  19. Radiation treatment for sterilization of packaging materials

    International Nuclear Information System (INIS)

    Haji-Saeid, Mohammad; Sampa, Maria Helena O.; Chmielewski, Andrzej G.

    2007-01-01

    Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology

  20. Sterile neutrino search in the STEREO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Christian; Lindner, Manfred; Roca, Christian [MPIK (Germany)

    2016-07-01

    In neutrino oscillations, a canonical understanding has been established during the last decades after the measurement of the mixing angles θ{sub 12}, θ{sub 23}, θ{sub 13} via solar, atmospheric and, most recently, reactor neutrinos. However, the re-evaluation of the reactor neutrino theoretical flux has forced a re-analysis of most reactor neutrino measurements at short distances. This has led to an unexpected experimental deficit of neutrinos with respect to the theory that needs to be accommodated, commonly known as the ''reactor neutrino anomaly''. This deficit can be interpreted as the existence of a light sterile neutrino state into which reactor neutrinos oscillate at very short distances. The STEREO experiment aims to find an evidence of such oscillations. The ILL research reactor in Grenoble (France) operates at a power of 58MW and provides a large flux of electron antineutrinos with an energy range of a few MeV. These neutrinos will be detected in a 2000 liter organic liquid scintillator detector doped with Gadolinium and consisting of 6 cells stacked along the direction of the core. Given the proximity of the detector, neutrinos will only travel a few meters until they interact with the scintillator. The detector will be placed about 10 m from the reactor core, allowing STEREO to be sensitive to oscillations into the above mentioned neutrino sterile state. The project presents a high potential for a discovery that would impact deeply the paradigms of neutrino oscillations and in consequence the current understanding of particle physics and cosmology.

  1. Impact of moth suppression/eradication programmes using the sterile insect technique or inherited sterility

    International Nuclear Information System (INIS)

    Bloem, K.A.; Bloem, S.; Carpenter, J.E.

    2005-01-01

    Numerous lepidopteran species have been investigated as candidates for control using the sterile insect technique (SIT) or inherited sterility (IS). However to date only two programmes are operational - the pink bollworm containment programme in the San Joaquin Valley, California, USA, and the codling moth suppression programme in British Columbia, Canada. Both of these programmes have been highly successful in controlling the pest populations, reducing insecticide use, and improving interactions between growers and the general public. However, other benefits, including the positive economic impacts of these programmes, have not been fully quantified. Methods to reduce the cost of lepidopteran programmes might include combining the SIT/IS with other pest control tactics such as mating disruption or the release of natural enemies, the development of genetic sexing strains, or the application of molecular technologies to develop genetic markers and genetic sterility. In future the greatest potential for impact of lepidopteran SIT/IS programmes may be in combating key invasive threats such as the eradication of an outbreak of the painted apple moth in New Zealand. (author)

  2. Fish culture data - Assessment of Normal Gonadal Differentiation and Development of Novel Approaches to Control Sex and Induce Reproductive Sterility in Sablefish

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Methods for reproductive sterilization are needed for marine aquaculture due to biosafety concerns associated with escapement of cultured fish from net pen systems...

  3. Sex control experiments - Assessment of Normal Gonadal Differentiation and Development of Novel Approaches to Control Sex and Induce Reproductive Sterility in Sablefish

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Methods for reproductive sterilization are needed for marine aquaculture due to biosafety concerns associated with escapement of cultured fish from net pen systems...

  4. Gene expression data - Assessment of Normal Gonadal Differentiation and Development of Novel Approaches to Control Sex and Induce Reproductive Sterility in Sablefish

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Methods for reproductive sterilization are needed for marine aquaculture due to biosafety concerns associated with escapement of cultured fish from net pen systems...

  5. Growth data - Assessment of Normal Gonadal Differentiation and Development of Novel Approaches to Control Sex and Induce Reproductive Sterility in Sablefish

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Methods for reproductive sterilization are needed for marine aquaculture due to biosafety concerns associated with escapement of cultured fish from net pen systems...

  6. A research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang

    2010-01-01

    Radiation sterilization is widely applied in food processing, Pharmaceutical Manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. The output value of radiation sterilization industry reached 0.1% of the GDP in some advanced countries (America and Japan...), under this standard, its output value in Sichuan province would be RMB1.2 hundred million, but now our capacity and scale of this industry is less than RMB40million.Research shows: there are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the 'bottleneck' restrictions of capacity and Inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity for radiation sterilization, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  7. Gamma ray induced male sterility mutant in lentil

    International Nuclear Information System (INIS)

    Srivastava, A.; Yadav, A.K.

    2001-01-01

    Full text: Male sterility refers to the failure of pollen grains to bring about effective fertilization, either due to structural default or physiological disfunctioning and has special significance in hybridization programmes. Male steriles have been produced in a number of crop plants like red gram, pigeon pea, mung bean, khesari and lentil. A completely male sterile mutant was isolated in Lens culinaris Medik, after seed treatment with 100 Gy dose of gamma rays. The male sterile mutant showed 100% pollen sterility but was morphologically more vigorous than the parent plants. It showed more branches and its leaves were bigger, more oblong and dark green. The number of flowers borne by the mutant was significantly higher than any other plant of the treatment. The size of the flowers was also increased but the anthers were smaller in size. Pollen grains were few in number, round in shape but empty and did not take up any stain, indicating that normal microsporogenesis had not taken place. This male sterile mutant was used as the female parent and pollinated with pollen of a parent. Four pods with one seed in each were formed indicating that the mutant was female fertile. The seeds were smaller than those of the parent variety and also dark coloured. The mutant showed increased vigour and flower number as compared to parental plants. Lentil is an important pulse crop and induction of variability in its germplasm is necessary for its improvement. Male steriles can be used conveniently in lentil hybridization programmes. (author)

  8. Canine sterile nodular panniculitis: a retrospective study of 39 dogs.

    Science.gov (United States)

    Contreary, Caitlin L; Outerbridge, Catherine A; Affolter, Verena K; Kass, Philip H; White, Stephen D

    2015-12-01

    Canine sterile nodular panniculitis (SNP) is an inflammatory disease of the panniculus that is typically managed with immunomodulatory or immunosuppressive treatments. It has been reported to be a cutaneous marker of an underlying systemic disease. To assess the presence or absence of concurrent systemic diseases associated with canine SNP and to document breed predispositions. Thirty nine dogs presented to a veterinary teaching hospital from 1990 to 2012 which met inclusion criteria. Inclusion in this retrospective study required a diagnosis of SNP via histopathological analysis and negative special stains for infectious organisms. Breed distributions of affected dogs were compared to all other dogs examined at this hospital during the study period. Correlations between the histological pattern of panniculitis and the histological presence of dermatitis, clinical presentation of lesions, dog breed and therapeutic outcomes were assessed. Australian shepherd dogs, Brittany spaniels, Dalmatians, Pomeranians and Chihuahuas were significantly over-represented, but correlations between inflammatory patterns of panniculitis and other histological and clinical factors were not identified. Based on the information available in medical records, 32 dogs (82.1%) had no concurrent systemic diseases identified. Four dogs had concurrent polyarthritis, which may be related to SNP through unknown mechanisms. This study identified several novel breed predilections for SNP; it failed to find any clear correlations with associated systemic diseases other than polyarthritis. The histological inflammatory pattern of SNP does not predict therapeutic outcome. © 2015 ESVD and ACVD.

  9. Gamma-irradiation sterilization of lipases for cheese making

    Energy Technology Data Exchange (ETDEWEB)

    Umanskij, M S; Borovkova, Yu A; Odegov, N I [Vsesoyuznyj Nauchno-Issledovatel' skij Inst. Maslodel' noj i Syrodel' noj Promyshlennosti, Uglich (USSR)

    1979-03-01

    The possibility of sterilizing the enzyme compounds of lipases from Oospora fragrans strains by gamma irradiation was studied. The enzyme compounds were exposed to gamma irradiation at the doses from 0.1 to 0.8 Mrad with the discreteness of 0.1 Mrad and at the dose of 2.0 Mrad. After the radiation treatment the lipases were investigated for bacterial invasion by the cultivation method and for the lipolytic activity by the titrometrical method. It is shown that the sterilization effect is achieved without losses of lipase activity and the radiation dose necessary for sterilization depends on initial invasion levels in the enzyme compounds.

  10. Sterility and meeting competitiveness of medfly, Ceratitis Capitata (Wiedemann)

    International Nuclear Information System (INIS)

    Taein-Tun; Molly-Maung-Maung

    2001-01-01

    The basic methodology in the determination of sterilising dosage in male med flies and mating competitiveness with the normal males was carried out in the laboratory. Application of the Sterile Insect Technique (S.I.T.) by three irradiation dosages on Seib-6096 pupae results in sterility when dosage increased. A lower mating competitiveness was observed with the increase in sterility value. This value was determined from the corrected egg hatch percent. The resulting data showed that irradiation dosage of γ 10.0 Krad gave a good advantage to suppress the population in the next generation. The method suggested a good application in the control and eradication of fruit flies. (author)

  11. Sterile Neutrino Search with the Double Chooz Experiment

    Science.gov (United States)

    Hellwig, D.; Matsubara, T.; Double Chooz Collaboration

    2017-09-01

    Double Chooz is a reactor antineutrino disappearance experiment located in Chooz, France. A far detector at a distance of about 1 km from reactor cores is operating since 2011; a near detector of identical design at a distance of about 400 m is operating since begin 2015. Beyond the precise measurement of θ 13, Double Chooz has a strong sensitivity to so called light sterile neutrinos. Sterile neutrinos are neutrino mass states not taking part in weak interactions, but may mix with known neutrino states. In this paper, we present an analysis method to search for sterile neutrinos and the expected sensitivity with the baselines of our detectors.

  12. Sterile neutrinos as the origin of dark and baryonic matter.

    Science.gov (United States)

    Canetti, Laurent; Drewes, Marco; Shaposhnikov, Mikhail

    2013-02-08

    We demonstrate for the first time that three sterile neutrinos alone can simultaneously explain neutrino oscillations, the observed dark matter, and the baryon asymmetry of the Universe without new physics above the Fermi scale. The key new point of our analysis is leptogenesis after sphaleron freeze-out, which leads to resonant dark matter production, evading thus the constraints on sterile neutrino dark matter from structure formation and x-ray searches. We identify the range of sterile neutrino properties that is consistent with all known constraints. We find a domain of parameters where the new particles can be found with present day experimental techniques, using upgrades to existing experimental facilities.

  13. Resonant Production of Sterile Neutrinos in the Early Universe

    Science.gov (United States)

    Gilbert, Lauren; Grohs, Evan; Fuller, George M.

    2016-06-01

    This study examines the cosmological impacts of a light resonantly produced sterile neutrino in the early universe. Such a neutrino could be produced through lepton number-driven Mikheyev-Smirnov-Wolfenstein (MSW) conversion of active neutrinos around big bang nucleosynthesis (BBN), resulting in a non-thermal spectrum of both sterile and electron neutrinos. During BBN, the neutron-proton ratio depends sensitively on the electron neutrino flux. If electron neutrinos are being converted to sterile neutrinos, this makes the n/p ratio a probe of possible new physics. We use observations of primordial Yp and D/H to place limits on this process.

  14. Bacterial spores survive treatment with commercial sterilants and disinfectants.

    Science.gov (United States)

    Sagripanti, J L; Bonifacino, A

    1999-09-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data obtained with a sensitive and quantitative test suggest that commercial liquid sterilants and disinfectants are less effective on contaminated surfaces than generally acknowledged.

  15. Use of radioimmunoassay to diagnose some forms of endocrine sterility

    International Nuclear Information System (INIS)

    Balabolkin, M.I.; Gerasimov, G.A.

    1984-01-01

    The possibility is considered of using a metoclopramide test combined with radioimmunoassay for determing prolactin in the blood to diagnose some forms of endocrine sterility Of 17 women examined 5 are practically healthy, sterility of 6 women is caused by tumor of hypophysis verified by X-rayograms, 6 women suffered from disorderded prolactin secretion and sterility without roentgenologic signs of disordered sella turcica. Metoclopramide has been injected intravenously in the 10 mm dose. A series of advantages is noted of the metoclopramide sample characteristic of high availability of the preparation and practically complete absence of side-effects

  16. Delayed pulsar kicks from the emission of sterile neutrinos

    International Nuclear Information System (INIS)

    Kusenko, Alexander; Mandal, Bhabani Prasad; Mukherjee, Alok

    2008-01-01

    The observed velocities of pulsars suggest the possibility that sterile neutrinos with mass of several keV are emitted from a cooling neutron star. The same sterile neutrinos could constitute all or part of cosmological dark matter. The neutrino-driven kicks can exhibit delays depending on the mass and the mixing angle, which can be compared with the pulsar data. We discuss the allowed ranges of sterile neutrino parameters, consistent with the latest cosmological and x-ray bounds, which can explain the pulsar kicks for different delay times

  17. The processing technology of bread crumbs sterilization by irradiation

    International Nuclear Information System (INIS)

    Zhu Jiating; Li Zhengkui; Zhao Yongfu; Zhang Weidong; Jin Jie; Wu Lei; Wang Xinghai

    2003-01-01

    The processing technology of bread crumbs sterilization by irradiation was studied. The results demonstrated that dose heterogeneity had osculatory connection with pile height and turning, sterilization effect had positive correlation with the irradiation dose and negative correlation with colour. Compared with the CK, the content of crud protein, fat, carbohydrate, microelement and amino acid in irradiated bread crumbs had no obvious change. It is recommended that the range of best sterilization dose be 6-10 kGy and the shelf time of bread crumbs be extended to one year

  18. Allelic interaction of F1 pollen sterility loci and abnormal chromosome behaviour caused pollen sterility in intersubspecific autotetraploid rice hybrids.

    Science.gov (United States)

    He, J H; Shahid, M Q; Li, Y J; Guo, H B; Cheng, X A; Liu, X D; Lu, Y G

    2011-08-01

    The intersubspecific hybrids of autotetraploid rice has many features that increase rice yield, but lower seed set is a major hindrance in its utilization. Pollen sterility is one of the most important factors which cause intersubspecific hybrid sterility. The hybrids with greater variation in seed set were used to study how the F(1) pollen sterile loci (S-a, S-b, and S-c) interact with each other and how abnormal chromosome behaviour and allelic interaction of F(1) sterility loci affect pollen fertility and seed set of intersubspecific autotetraploid rice hybrids. The results showed that interaction between pollen sterility loci have significant effects on the pollen fertility of autotetraploid hybrids, and pollen fertility further decreased with an increase in the allelic interaction of F(1) pollen sterility loci. Abnormal ultra-structure and microtubule distribution patterns during pollen mother cell (PMC) meiosis were found in the hybrids with low pollen fertility in interphase and leptotene, suggesting that the effect-time of pollen sterility loci interaction was very early. There were highly significant differences in the number of quadrivalents and bivalents, and in chromosome configuration among all the hybrids, and quadrivalents decreased with an increase in the seed set of autotetraploid hybrids. Many different kinds of chromosomal abnormalities, such as chromosome straggling, chromosome lagging, asynchrony of chromosome disjunction, and tri-fission were found during the various developmental stages of PMC meiosis. All these abnormalities were significantly higher in sterile hybrids than in fertile hybrids, suggesting that pollen sterility gene interactions tend to increase the chromosomal abnormalities which cause the partial abortion of male gametes and leads to the decline in the seed set of the autotetraploid rice hybrids. © 2011 The Author(s).

  19. Management of long-term and reversible hysteroscopic sterilization: a novel device with nickel-titanium shape memory alloy

    Science.gov (United States)

    2014-01-01

    Background Female sterilization is the second most commonly used method of contraception in the United States. Female sterilization can now be performed through laparoscopic, abdominal, or hysteroscopic approaches. The hysteroscopic sterilization may be a safer option than sterilization through laparoscopy or laparotomy because it avoids invading the abdominal cavity and undergoing general anaesthesia. Hysteroscopic sterilization mainly includes chemical agents and mechanical devices. Common issues related to the toxicity of the chemical agents used have raised concerns regarding this kind of contraception. The difficulty of the transcervical insertion of such mechanical devices into the fallopian tubes has increased the high incidence of device displacement or dislodgment. At present, Essure® is the only commercially available hysteroscopic sterilization device being used clinically. The system is irreversible and is not effective immediately. Presentation of the hypothesis Our new hysteroscopic sterility system consists of nickel-titanium (NiTi) shape memory alloy and a waterproof membrane. The NiTi alloy is covered with two coatings to avoid toxic Ni release and to prevent stimulation of epithelial tissue growth around the oviducts. Because of the shape memory effect of the NiTi alloy, the device works like an umbrella: it stays collapsed at low temperature before placement and opens by the force of shape memory activated by the body temperature after it is inserted hysteroscopically into the interstitial tubal lumen. The rim of the open device will incise into interstitial myometrium during the process of unfolding. Once the device is fixed, it blocks the tube completely. When the patient no longer wishes for sterilization, the device can be closed by perfusing liquid with low temperature into the uterine cavity, followed by prospective hysteroscopic removal. After the device removal, the fallopian tube will revert to its physiological functions. Testing the

  20. Belgian experience with radiation technologies for sterilization

    International Nuclear Information System (INIS)

    Bonet, H.; Dardenne, P.; Herier, A.

    1998-01-01

    Belgium pioneered in non energetic applications of nuclear science. In 1970, the National Institute for Radioisotopes (IRE) was founded on the ground of the experience acquired at the CEN/SCK, for developing nuclear techniques oriented to the well-being of population. In 1978 IRE started operation of 2 γ-irradiation units with a 2.25 million Ci Co 60 , source having a capacity for sterilization of more than 100 m 3 of product per day. this installation is currently operated by Griffith-Mediris (Group Griffith Micro Science) and has accumulated 20 years of experience for irradiation of foodstuffs, medical appliances and pharmaceuticals. In 1986, IRE was producing radioisotopes from accelerators and joined UCL for founding Ion Beam Applications (IBA) company which shortly became the world leader for design and delivery of cyclotrons. More recently, on the basis of French CEA patent, IBA developed the Rhodotron, an e-beam accelerator, with an X-ray option, which is now facing commercial success i area of ionization of food and medical appliances. IRE developed also expertise for the back-end of these activities i.e. final disposal of radioactive sealed source and dismantling of the installations. (author)

  1. Infection Risk in Sterile Operative Procedures.

    Science.gov (United States)

    Tacconelli, Evelina; Müller, Niklas F; Lemmen, Sebastian; Mutters, Nico T; Hagel, Stefan; Meyer, Elisabeth

    2016-04-22

    The main objective of hospital hygiene and infection prevention is to protect patients from preventable nosocomial infections. It was recently stated that the proper goal should be for zero infection rates in sterile surgical procedures. In this article, we attempt to determine whether this demand is supported by the available literature. We systematically searched the Medline and EMBASE databases for studies published in the last 10 years on the efficacy of infection control measures and carried out a meta-analysis according to the PRISMA tool. We used the following search terms: "aseptic surgery," "intervention," "surgical site infection," "nosocomial infection," "intervention," and "prevention." 2277 articles were retrieved, of which 204 were acquired in full text and analyzed. The quantitative analysis included 7 prospective cohort studies on the reduction of nosocomial infection rates after aseptic surgery. The measures used included training sessions, antibiotic prophylaxis, and operative-site disinfection and cleaning techniques. These interventions succeeded in reducing postoperative wound infections (relative risk (RR] 0.99 [0.98; 1.00]). Subgroup analyses on antibiotic prophylaxis (RR 0.99 [0.98; 1.01]) and noncontrolled trials (RR 0.97 [0.92; 1.02]) revealed small, insignificant effects. A multimodal approach with the participation of specialists from various disciplines can further reduce the rate of postoperative infection. A reduction to zero is not realistic and is not supported by available evidence.

  2. Twenty years of radiation sterilization in Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Razem, Dusan E-mail: razem@irb.hr

    2004-10-01

    The development of radiation processing in Croatia is described from its inception 20 years ago up to the present time. Annual throughputs of treated materials are given by the categories of materials and pertaining volumes. The pasteurization of hard gelatine capsules occured during the early stages, while sterilization of disposable medical supplies has been dominant in the later stages. Irradiation of foods and of cosmetics and toiletries has been a minor fraction of the total throughput. Since the recovery of everyday life and economy of the country after the war, the total throughput has increased steadily to reach 13,000 m{sup 3} kGy in 2002, 90% of which are medical supplies. Estimates of the present maximum capacity of 30,000 m{sup 3} kGy and of future needs indicate that the present rate of growth could be sustained for the next several years only, unless a major upgrading is undertaken. An estimate of potential future needs is made.

  3. Transcriptional regulation of male-sterility in 7B-1 male-sterile tomato mutant.

    Directory of Open Access Journals (Sweden)

    Vahid Omidvar

    Full Text Available The 7B-1 tomato (Solanum lycopersicum L. cv Rutgers is a male-sterile mutant with enhanced tolerance to abiotic stress, which makes it a potential candidate for hybrid seed breeding and stress engineering. To underline the molecular mechanism regulating the male-sterility in 7B-1, transcriptomic profiles of the 7B-1 male-sterile and wild type (WT anthers were studied using mRNA sequencing (RNA-Seq. In total, 768 differentially expressed genes (DEGs were identified, including 132 up-regulated and 636 down-regulated transcripts. Gene ontology (GO enrichment analysis of DEGs suggested a general impact of the 7B-1 mutation on metabolic processes, such as proteolysis and carbohydrate catabolic process. Sixteen candidates with key roles in regulation of anther development were subjected to further analysis using qRT-PCR and in situ hybridization. Cytological studies showed several defects associated with anther development in the 7B-1 mutant, including unsynchronized anther maturation, dysfunctional meiosis, arrested microspores, defect in callose degradation and abnormal tapetum development. TUNEL assay showed a defect in programmed cell death (PCD of tapetal cells in 7B-1 anthers. The present study provides insights into the transcriptome of the 7B-1 mutant. We identified several genes with altered expression level in 7B-1 (including beta-1,3 glucanase, GA2oxs, cystatin, cysteine protease, pectinesterase, TA29, and actin that could potentially regulate anther developmental processes, such as meiosis, tapetum development, and cell-wall formation/degradation.

  4. Radiation sterilization of traditional medicine drugs in Vietnam

    International Nuclear Information System (INIS)

    Hang, N.D.; Canh, T.T.; Thuy, T.T.

    1995-01-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author)

  5. Radiation sterilization of traditional medicine drugs in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Hang, N.D.; Canh, T.T.; Thuy, T.T. [Nuclear Research Inst., Da Lat (Viet Nam)

    1995-10-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author).

  6. Possibilities of sterilizing nutrient media used to grow tissue cultures

    International Nuclear Information System (INIS)

    Veber, P.; Leshko, Ya.; Gana, L.; Yankovicheva, T.; Yurmanova, K.

    1976-01-01

    Effects of radiosterilization on the properties of liquid and powdery Eagle's media and on inactivated calf and horse sera are described. It is shown that radiosterilization may be employed to sterilize biological agents required for in vitro cell cultivation. (author)

  7. Sterilization validation for medical compresses at IRASM multipurpose irradiation facility

    International Nuclear Information System (INIS)

    Alexandru, Mioara; Ene, Mihaela

    2007-01-01

    In Romania, IRASM Radiation Processing Center is the unique supplier of radiation sterilization services-industrial scale (ISO 9001:2000 and ISO 13485:2003 certified). Its Laboratory of Microbiological Testing is the sole third party competent laboratory (GLPractice License, ISO 17025 certification in progress) for pharmaceutics and medical devices as well. We here refer to medical compresses as a distinct category of sterile products, made from different kind of hydrophilic materials (cotton, non-woven, polyurethane foam) with or without an impregnated ointment base (paraffin, plant extracts). These products are included in the class of medical devices, but for the sterilization validation, from microbiological point of view, there are important differences in testing method compared to the common medical devices (syringes, catheters, etc). In this paper, we present some results and practical solutions chosen to perform a sterilization validation, compliant with ISO 11137: 2006

  8. Eugenics, sterilization, and historical memory in the United States

    Directory of Open Access Journals (Sweden)

    Alexandra Minna Stern

    Full Text Available Abstract From the 1920s to the 1950s, California sterilized approximately 20,000 people in state homes and hospitals based on a eugenic law that authorized medical superintendents to perform reproductive surgeries on patients deemed unfit and “suffering from a mental affliction likely to be inherited.” Working with a unique resource – a dataset created from 19,000 sterilization recommendations – my team and I have reconstructed patterns and experiences of institutionalization of sterilizations. This article presents several of our important initial findings related to ethnic and gender bias in sterilization policies, and reflects on the relevance of the history for contemporary issues in genomics and social justice.

  9. Clean Air Act Standards and Guidelines for Sterilizers

    Science.gov (United States)

    This page contains the stationary sources of air pollution for the sterilizer industries, and their corresponding air pollution regulations. To learn more about the regulations for each industry, just click on the links below.

  10. Cosmological lepton asymmetry, primordial nucleosynthesis and sterile neutrinos

    Science.gov (United States)

    Abazajian, Kevork; Bell, Nicole F.; Fuller, George M.; Wong, Yvonne Y. Y.

    2005-09-01

    We study post weak decoupling coherent active-sterile and active-active matter-enhanced neutrino flavor transformation in the early Universe. We show that flavor conversion efficiency at Mikheyev-Smirnov-Wolfenstein resonances is likely to be high (adiabatic evolution) for relevant neutrino parameters and energies. However, we point out that these resonances cannot sweep smoothly and continuously with the expansion of the Universe. We show how neutrino flavor conversion in this way can leave both the active and sterile neutrinos with nonthermal energy spectra, and how, in turn, these distorted energy spectra can affect the neutron-to-proton ratio, primordial nucleosynthesis, and cosmological mass/closure constraints on sterile neutrinos. We demonstrate that the existence of a light sterile neutrino which mixes with active neutrinos can change fundamentally the relationship between the cosmological lepton numbers and the primordial nucleosynthesis He4 yield.

  11. Postpartum Sterilization Choices Made by HIV-Infected Women

    Directory of Open Access Journals (Sweden)

    Gretchen S. Stuart

    2005-01-01

    Full Text Available Objective. To assess if HIV-infected women made different choices for postpartum sterilization after implementation of the Pediatric AIDS Clinical Trials Group protocol 076 (November 1, 1994 compared to before implementation.

  12. Design, Construction and Evaluation of a Dry Solar Sterilizer

    International Nuclear Information System (INIS)

    Hernández Fereira, Arcelio A.

    2017-01-01

    The objective of the work was the search of an alternative for sterilization using solar energy. For such purposes, a dry solar sterilizer of 4276 cm3 capacity was designed, constructed and evaluated. Potential users would be rural medical posts in areas without electricity, health posts in military units under field conditions, and experimental microbiology stations. The evaluation included the determination of the energy efficiency of the sterilizer, the economic evaluation against other variants and the biological safety assessment. The developed equipment reached the sterilization temperature for levels of the direct component of the solar radiation higher than 300 W/m2 in 14 minutes, corresponding to an average heating rate of 13 0C/minute, higher than that of an electric furnace. Its energy efficiency with direct solar radiation of 310.5 W/m2 was 53.79%. The equipment is of easy construction, simple operation and very low cost. (author)

  13. Degradation and stability of polycarbonate sterilized by gamma rays

    International Nuclear Information System (INIS)

    Araujo, E.S.; Guedes, S.M.L.

    1995-01-01

    The purpose of this paper is to study the behavior of the polycarbonate (poly (bis phenol-A carbonate)) when it is sterilized by gamma rays because undesirable discoloration appears. Aromatic polycarbonates are amorphous polymers usually prepared from bis phenols and phosgene by interfacial polymerization. They are employed in medical applications, including blood filters, dialyzers, oxygenators and sterilizing equipment. At present, the best process for sterilization of medical supplies is present, the best process for sterilization of medical supplies is gamma irradiation. The two major effects of γ-radiation in polymers are crosslinking and main chain scission. Both effects coexist and either one may predominate depending on the chemical structure of the polymer and the conditions of irradiation. (author). 5 refs, 6 figs, 1 tab

  14. Use of geoprocessing tools in uranium mining: volume estimation of sterile piles from the Osamu Utsumi Mine of INB / Caldas

    International Nuclear Information System (INIS)

    Ferreira, A.M.; Menezes, P.H.B.J.; Alberti, H.L.C.; Silva, N.C. da; Goda, R.T.

    2017-01-01

    The determination of the volumes of the sterile piles generated in the uranium mining and their respective characterization is of extreme importance for the management of mining wastes and future decommissioning actions of a nuclear facility. With the development of information technology, it becomes possible to simulate different scenarios in a computational environment, being able to store, represent and process data from existing information. In the industrial mining context, the sterile is represented with rocky materials of different granulometries and with ore content below the cut content determined by the industrial process. In this sense, the present work has the objective of calculating the volume of the sterile stacks of the Osamu Utsumi uranium mine of INB - Nuclear Industries of Brazil / Caldas. The MOU was officially inaugurated in 1977 and operated until 1995, where 1,200 tons of U 2 O 3 were produced generating about 94.5 x 106 tons of sterile material containing low levels of radioactive material and pyrite. The methodology for the development of this work initially involves integration approaches between the Geographic Information System (GIS) and terrain modeling for the sterile piles called BF4 and BF8. The results obtained were compared with the existing literature, translating the importance of GIS as a tool in the management of wastes

  15. Mating competitiveness of sterile male Anopheles coluzzii in large cages.

    Science.gov (United States)

    Maïga, Hamidou; Damiens, David; Niang, Abdoulaye; Sawadogo, Simon P; Fatherhaman, Omnia; Lees, Rosemary S; Roux, Olivier; Dabiré, Roch K; Ouédraogo, Georges A; Tripet, Fréderic; Diabaté, Abdoulaye; Gilles, Jeremie R L

    2014-11-26

    Understanding the factors that account for male mating competitiveness is critical to the development of the sterile insect technique (SIT). Here, the effects of partial sterilization with 90 Gy of radiation on sexual competitiveness of Anopheles coluzzii allowed to mate in different ratios of sterile to untreated males have been assessed. Moreover, competitiveness was compared between males allowed one versus two days of contact with females. Sterile and untreated males four to six days of age were released in large cages (~1.75 sq m) with females of similar age at the following ratios of sterile males: untreated males: untreated virgin females: 100:100:100, 300:100:100, 500:100:100 (three replicates of each) and left for two days. Competitiveness was determined by assessing the egg hatch rate and the insemination rate, determined by dissecting recaptured females. An additional experiment was conducted with a ratio of 500:100:100 and a mating period of either one or two days. Two controls of 0:100:100 (untreated control) and 100:0:100 (sterile control) were used in each experiment. When males and females consort for two days with different ratios, a significant difference in insemination rate was observed between ratio treatments. The competitiveness index (C) of sterile males compared to controls was 0.53. The number of days of exposure to mates significantly increased the insemination rate, as did the increased number of males present in the untreated: sterile male ratio treatments, but the number of days of exposure did not have any effect on the hatch rate. The comparability of the hatch rates between experiments suggest that An. coluzzii mating competitiveness experiments in large cages could be run for one instead of two days, shortening the required length of the experiment. Sterilized males were half as competitive as untreated males, but an effective release ratio of at least five sterile for one untreated male has the potential to impact the fertility of

  16. Periodontal instrumentation for the general dental practitioner: Pt. 2. Management maintenance and sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Touyz, L.Z.G. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Oral Medicine and Periodontology); De Waal, J.

    1983-03-01

    The purpose of this article is to describe the management, maintenance and sterilization of periodontal instrumentation used by the general dental practitioner. The pre-sterilization, decontamination and cleaning, the sharpening of instrumentation and the packaging, identification and grouping for sterilization are discussed. Attention is also given to various techniques of sterilization, including gamma radiation.

  17. Guide for dosimetry for sterile insect release programs. 2. ed.

    International Nuclear Information System (INIS)

    2004-01-01

    This guide outlines dosimetric procedures to be followed for the radiation sterilization of live insects for use in pest management programs. The primary use of irradiated, reproductively sterile insects is in the Sterile Insect Technique, where large numbers of sterile insects are released into the field to mate with and thus control pest populations of the same species. A secondary use of sterile insects is as benign hosts for rearing insect parasitoids. The procedures outlined in this guide will help ensure that insects processed with ionizing radiation from gamma, electron, or X-ray sources receive absorbed doses within a predetermined range. Information on effective dose ranges for specific applications of insect sterilization, or on methodology for determining effective dose ranges, is not within the scope of this guide. Note: Dosimetry is only one component of a total quality control program to ensure that irradiated insects are adequately sterilized and sufficiently competitive or otherwise suitable for their intended purpose. This guide covers dosimetry in the irradiation of insects for these types of irradiators: self-contained dry-storage 137 Cs or 60 Co irradiators, large-scale gamma irradiators, and electron accelerators. Additional, detailed information on dosimetric procedures to be followed in installation qualification, operational qualification, performance qualification, and routine product processing can be found in ISO/ASTM Practices 51608 (X-ray [bremsstrahlung] facilities), 51649 (electron beam facilities), 51702 (large-scale gamma facilities), and ASTM Practice E 2116 (self-contained dry-storage gamma facilities). The absorbed dose for insect sterilization is typically within the range of 20 Gy to 600 Gy

  18. Sterilization of Lung Matrices by Supercritical Carbon Dioxide.

    Science.gov (United States)

    Balestrini, Jenna L; Liu, Angela; Gard, Ashley L; Huie, Janet; Blatt, Kelly M S; Schwan, Jonas; Zhao, Liping; Broekelmann, Tom J; Mecham, Robert P; Wilcox, Elise C; Niklason, Laura E

    2016-03-01

    Lung engineering is a potential alternative to transplantation for patients with end-stage pulmonary failure. Two challenges critical to the successful development of an engineered lung developed from a decellularized scaffold include (i) the suppression of resident infectious bioburden in the lung matrix, and (ii) the ability to sterilize decellularized tissues while preserving the essential biological and mechanical features intact. To date, the majority of lungs are sterilized using high concentrations of peracetic acid (PAA) resulting in extracellular matrix (ECM) depletion. These mechanically altered tissues have little to no storage potential. In this study, we report a sterilizing technique using supercritical carbon dioxide (ScCO2) that can achieve a sterility assurance level 10(-6) in decellularized lung matrix. The effects of ScCO2 treatment on the histological, mechanical, and biochemical properties of the sterile decellularized lung were evaluated and compared with those of freshly decellularized lung matrix and with PAA-treated acellular lung. Exposure of the decellularized tissue to ScCO2 did not significantly alter tissue architecture, ECM content or organization (glycosaminoglycans, elastin, collagen, and laminin), observations of cell engraftment, or mechanical integrity of the tissue. Furthermore, these attributes of lung matrix did not change after 6 months in sterile buffer following sterilization with ScCO2, indicating that ScCO2 produces a matrix that is stable during storage. The current study's results indicate that ScCO2 can be used to sterilize acellular lung tissue while simultaneously preserving key biological components required for the function of the scaffold for regenerative medicine purposes.

  19. How self-interactions can reconcile sterile neutrinos with cosmology.

    Science.gov (United States)

    Hannestad, Steen; Hansen, Rasmus Sloth; Tram, Thomas

    2014-01-24

    Short baseline neutrino oscillation experiments have shown hints of the existence of additional sterile neutrinos in the eV mass range. However, such neutrinos seem incompatible with cosmology because they have too large of an impact on cosmic structure formation. Here we show that new interactions in the sterile neutrino sector can prevent their production in the early Universe and reconcile short baseline oscillation experiments with cosmology.

  20. Pharmaceutical aerosols. Study of their gamma radiation sterilization

    International Nuclear Information System (INIS)

    Sebert, P.

    1984-10-01

    The gamma radiation sterilization of pharmaceutical aerosols was studied. The following topics were investigated: radiosterilization of nitrogen protoxide used as a propellant; radiosterilization of packaging materials (aluminium containers, plastics valves); radio-sterilization of excipients and active ingredients. Most of the investigated materials proved to be stable to irradiation (2,5 Mrads) from pharmacopoeial aspect. Stability tests of the preparations packaged showed no change in the parameters investigated [fr

  1. Bacterial Spores Survive Treatment with Commercial Sterilants and Disinfectants

    OpenAIRE

    Sagripanti, Jose-Luis; Bonifacino, Aylin

    1999-01-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data ob...

  2. Genetic complexity underlying hybrid male sterility in Drosophila.

    OpenAIRE

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-01-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic b...

  3. Gamma radiations an effective way of monoclonal antibodies sterilization

    International Nuclear Information System (INIS)

    Lenay Barrera Barroso, Lenay; Otero Abreu, Isabel; Rodriguez Napoles, Dania; Bulte Ocanna, Dubhe; Caballero, Idania

    2006-01-01

    The sterilization for radiations of pharmaceutical products is an effective, sure and reliable procedure; that it have been proving technically and grateful for different pharmacopoeia. The Monoclonal Antibodies (Acm) produced in the Center of Molecular Immunology (CIM) are products parenteral for the one which results indispensable that they complete the requirements of established sterility. The radio sterilization result the method more recommend for the sterilization of the Acm deep drying, due to the contained first floor of humidity remnant that minimizes the formation of sub-product that they affect their properties. With the objective of proposing a good dose of irradiation for the sterilization, we were carried out a study of the radius sensibility so much of the product like of the polluting of greater frequency of isolation of the clean area of the CIM. The characterization of the radius sensibility of the different micro- organisms was determined by D 10 characteristic of each isolated strains. From the developed studies the Gram-positive rods endospore-forming were the most resistant strains at the deep drying, the radiations and they were of the greater frequency of apparition in the carried out isolations. We could conclude that utilizing a dose of 10 kGy it is possible to eliminate of the pollution more radio resistant, assuring the sterility required in the product, and without inducing effects under desire radiolytic in the same

  4. A search for sterile neutrinos with the latest cosmological observations

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Lu; Zhang, Jing-Fei [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Zhang, Xin [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Peking University, Center for High Energy Physics, Beijing (China)

    2017-06-15

    We report the result of a search for sterile neutrinos with the latest cosmological observations. Both cases of massless and massive sterile neutrinos are considered in the ΛCDM cosmology. The cosmological observations used in this work include the Planck 2015 temperature and polarization data, the baryon acoustic oscillation data, the Hubble constant direct measurement data, the Planck Sunyaev-Zeldovich cluster counts data, the Planck lensing data, and the cosmic shear data. We find that the current observational data give a hint of the existence of massless sterile neutrino (as dark radiation) at the 1.44σ level, and the consideration of an extra massless sterile neutrino can indeed relieve the tension between observations and improve the cosmological fit. For the case of massive sterile neutrino, the observations give a rather tight upper limit on the mass, which implies that actually a massless sterile neutrino is more favored. Our result is consistent with the recent result of neutrino oscillation experiment done by the Daya Bay and MINOS collaborations, as well as the recent result of cosmic ray experiment done by the IceCube collaboration. (orig.)

  5. Development of atmospheric pressure plasma needle jet for sterilization applications

    Science.gov (United States)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Soon, Chin Fhong; Sahdan, Mohd Zainizan; Lias, Jais; Wibowo, Kusnanto Mukti; Bakar, Ahmad Shuhaimi Abu; Arshad, Mohd Khairuddin Md; Hashim, Uda; Nayan, Nafarizal

    2017-09-01

    Inactivation of bacteria or sterilization has been a major issue in the medical field, especially regarding of human safety, whereby, in a huge scenario fatality can be caused by hazardous bacteria. Often, E-coli as gram-negative bacteria are selected as a key indicator of proper sterilization process as E-coli is tough and dormant bacteria. The technology in sterilization has moved on from chemical, wet and irradiation sterilization to a high promising device such as atmospheric pressure plasma needle jet (APPNJ). It has been reported that atmospheric pressure plasma has provided bundle of advantages over earlier sterilization process. The APPNJ is developed in our lab using high frequency and high voltage neon transformer power supply connected to copper needle and copper sheet electrodes. The gas discharge is Ar gas flowing at 40 L/min through a quartz glass tube. The E-coli bacteria are self-cultured from waste water and then treated with APPNJ. The treatment processes are run into two difference gaps between the plasma orifice and sample with various treatment times. Only 40s is required by direct treatment to achieve 100% killing of E-coli. On the other hand, indirect treatment has inactivated 50% of the E-coli in 40s. In this study, direct and indirect effect of APPNJ to the E-coli can be observed which can be utilized into sterilization of bio-compatible material applications.

  6. Sterilizing elastomeric chains without losing mechanical properties. Is it possible?

    Directory of Open Access Journals (Sweden)

    Matheus Melo Pithon

    2015-06-01

    Full Text Available OBJECTIVE: To investigate the effects of different sterilization/disinfection methods on the mechanical properties of orthodontic elastomeric chains. METHODS: Segments of elastomeric chains with 5 links each were sent for sterilization by cobalt 60 (Co60 (20 KGy gamma ray technology. After the procedure, the elastomeric chains were contaminated with clinical samples of Streptococcus mutans. Subsequently, the elastomeric chains were submitted to sterilization/disinfection tests carried out by means of different methods, forming six study groups, as follows: Group 1 (control - without contamination, Group 2 (70°GL alcohol, Group 3 (autoclave, Group 4 (ultraviolet, Group 5 (peracetic acid and Group 6 (glutaraldehyde. After sterilization/disinfection, the effectiveness of these methods, by Colony forming units per mL (CFU/mL, and the mechanical properties of the material were assessed. Student's t-test was used to assess the number of CFUs while ANOVA and Tukey's test were used to assess elastic strength. RESULTS: Ultraviolet treatment was not completely effective for sterilization. No loss of mechanical properties occurred with the use of the different sterilization methods (p > 0.05. CONCLUSION: Biological control of elastomeric chains does not affect their mechanical properties.

  7. Remodeling of ACL Allografts is Inhibited by Peracetic Acid Sterilization

    Science.gov (United States)

    Gonnermann, Johannes; Kamp, Julia; Przybilla, Dorothea; Pruss, Axel

    2008-01-01

    Sterilization of allografts for anterior cruciate ligament (ACL) reconstruction has become an important prerequisite to prevent disease transmission. However, current sterilization techniques impair the biological or mechanical properties of such treated grafts. Peracetic acid (PAA) has been successfully used to sterilize bone allografts without these disadvantages and does not impair the mechanical properties of soft tissue grafts in vitro. We asked whether PAA sterilization would influence recellularization, restoration of crimp length and pattern, and revascularization of ACL grafts during early healing. We used an in vivo sheep model for open ACL reconstruction. We also correlated the histologic findings with the restoration of anteroposterior stability and structural properties during load-to-failure testing. PAA slowed remodeling activity at 6 and 12 weeks compared to nonsterilized allografts and autografts. The mechanical properties of PAA grafts were also reduced compared to these control groups at both time points. We conclude PAA sterilization currently should not be used to sterilize soft tissue grafts typically used in ACL reconstruction. PMID:18491201

  8. Effects of Sterilization Cycles on PEEK for Medical Device Application

    Science.gov (United States)

    Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-01-01

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed. PMID:29466289

  9. Effect of fermentation and sterilization on anthocyanins in blueberry.

    Science.gov (United States)

    Nie, Qixing; Feng, Lei; Hu, Jielun; Wang, Sunan; Chen, Haihong; Huang, Xiaojun; Nie, Shaoping; Xiong, Tao; Xie, Mingyong

    2017-03-01

    Blueberry products have various health benefits due to their high content of dietary anthocyanins. The aim of this study was to investigate the impact of fermentation and sterilization on total anthocyanin content, composition and some quality attributes of blueberry puree. The blueberry puree used here was fermented for 40 h at 37 °C by Lactobacillus after sterilization. The method of ultra-performance liquid chromatography-mass spectrometry was optimized for the rapid analysis of anthocyanins. Quality attributes including pH, color, total soluble solids and viscosity were measured. A total of 21 anthocyanins and five anthocyanidins were quantified by ultra-performance liquid chromatography. Fermented blueberry had reduced total anthocyanin content (29%) and levels of individual anthocyanins compared with fresh blueberry. Total anthocyanin content was decreased 46% by sterilization, and different degradation behavior of individual anthocyanin was appeared between fermented and sterilized-fermented blueberry puree. Fermentation and sterilization decreased the total soluble solids and pH and changed color parameters, while minimally influencing viscosity. The loss of total anthocyanin content by fermentation was related to the unstable structure of blueberry anthocyanins. Anthocyanins are sensitive to temperature (>80 °C), and degradation of anthocyanins by sterilization in blueberry should be considered in the fermentation procedure. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  10. Sterile Neutrino Search in the NOvA Far Detector

    Energy Technology Data Exchange (ETDEWEB)

    Edayath, Sijith [Cochin U.; Aurisano, Adam [Cincinnati U.; Sousa, Alexandre [Cincinnati U.; Davies, Gavin [Indiana U.; Suter, Louise [Fermilab; Yang, Shaokai [Cincinnati U.

    2017-10-03

    The majority of neutrino oscillation experiments have obtained evidence for neutrino oscillations that are compatible with the three-flavor model. Explaining anomalous results from short-baseline experiments, such as LSND and MiniBooNE, in terms of neutrino oscillations requires the existence of sterile neutrinos. The search for sterile neutrino mixing conducted in NOvA uses a long baseline of 810 km between Near Detector (ND) at Fermilab and Far Detector (FD) in Minnesota. The signal for sterile neutrino oscillations is a deficit of neutral-current neutrino interactions at the FD with respect to the ND prediction. In this document, We will present the analysis improvements that we are implementing for future NC sterile neutrino searches with NOvA. These include: improved modelling of our detector response; the inclusion of NC 2p2h interaction modelling; implementing a better energy reconstruction techniques; and including possible oscillation due to sterile neutrinos in the ND . This improvements enable us to do a simultaneous ND-FD shape fit of the NC energy spectrum covering a wider sterile mass range than previous analyses.

  11. Sterilization techniques without heating (ultraviolet ray, radiation and ozone)

    International Nuclear Information System (INIS)

    Ito, Hitoshi

    1991-01-01

    The recent demand of consumers for processed foods is characterized by the intention for health and nature, besides, the demand for low sweetness, salt reduction, no additive and freshness becomes strong. In view of the control of microorganisms in products, all these become the negative factors. Accordingly, in order to overcome them, it is urgently desired to develop new technology or to improve conventional methods. As to heating sterilization, the uniform temperature treatment to the inside of foods is difficult, and it cannot be applied to perishables. The high temperature sterilization above 120degC causes the change in nutrition composition and physical properties. Ultraviolet ray and ozone can be used for the sterilization of food surface and powder and liquid foods. Radiation treatment can be applied to packed foods and frozen foods as well as food surface. The principle and the fields of application of ultraviolet ray sterilization, radiation sterilization and ozone sterilization are reported. In the mechanism of these methods, the action to DNA and oxidation are common. (K.I.)

  12. Effects of Sterilization Cycles on PEEK for Medical Device Application.

    Science.gov (United States)

    Kumar, Amit; Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-02-21

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed.

  13. Electric dipole moments of charged leptons with sterile fermions

    International Nuclear Information System (INIS)

    Abada, Asmaa; Toma, Takashi

    2016-01-01

    We address the impact of sterile fermions on charged lepton electric dipole moments. Any experimental signal of these observables calls for scenarios of physics beyond the Standard Model providing new sources of CP violation. In this work, we consider a minimal extension of the Standard Model via the addition of sterile fermions which mix with active neutrinos and we derive the corresponding analytical expressions for the electric dipole moments of charged leptons at two-loop order. Our study reveals that, in order to have a non-vanishing contribution in this framework, the minimal extension necessitates the addition of at least 2 sterile fermion states to the Standard Model field content. Our conclusion is that sterile neutrinos can give significant contributions to the charged lepton electric dipole moments, some of them lying within present and future experimental sensitivity if the masses of the non-degenerate sterile states are both above the electroweak scale. The Majorana nature of neutrinos is also important in order to allow for significative contributions to the charged lepton electric dipole moments. In our analysis we impose all available experimental and observational constraints on sterile neutrinos and we further discuss the prospect of probing this scenario at low and high energy experiments.

  14. Electric dipole moments of charged leptons with sterile fermions

    Energy Technology Data Exchange (ETDEWEB)

    Abada, Asmaa; Toma, Takashi [Laboratoire de Physique Théorique, CNRS, University Paris-Sud, Université Paris-Saclay, 91405 Orsay (France)

    2016-02-26

    We address the impact of sterile fermions on charged lepton electric dipole moments. Any experimental signal of these observables calls for scenarios of physics beyond the Standard Model providing new sources of CP violation. In this work, we consider a minimal extension of the Standard Model via the addition of sterile fermions which mix with active neutrinos and we derive the corresponding analytical expressions for the electric dipole moments of charged leptons at two-loop order. Our study reveals that, in order to have a non-vanishing contribution in this framework, the minimal extension necessitates the addition of at least 2 sterile fermion states to the Standard Model field content. Our conclusion is that sterile neutrinos can give significant contributions to the charged lepton electric dipole moments, some of them lying within present and future experimental sensitivity if the masses of the non-degenerate sterile states are both above the electroweak scale. The Majorana nature of neutrinos is also important in order to allow for significative contributions to the charged lepton electric dipole moments. In our analysis we impose all available experimental and observational constraints on sterile neutrinos and we further discuss the prospect of probing this scenario at low and high energy experiments.

  15. Feasibility Study on Sterilization of Badge using Radiation and Cultivation by Nano-bubble Water for Matsutake Mushroom Cultivation

    International Nuclear Information System (INIS)

    Jung, Inha

    2013-12-01

    This report on the 'Sterilization of Badge using Radiation and Cultivation by Nano-bubble Water for Matsutake Mushroom Cultivation' is belonged to the final report on the preliminary study of the first subject in 2013 for civilian project. This was complimented on the responsible of the Korea Atomic Energy Research Institute for 1 st of June 2013 to 30 th of November 2013. We are going to make sterilization the badge using the gamma ray and supplying the oxygen by nano-bubble oxygen rich water for cultivating the Matsutake Mushroom, instead of the conventional process of sterilization of the badge by hot steam over 120 .deg. C consuming over 8 hours and expensive ventilation system for supplying the fresh air for delivering the oxygen

  16. Feasibility Study on Sterilization of Badge using Radiation and Cultivation by Nano-bubble Water for Matsutake Mushroom Cultivation

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Inha

    2013-12-15

    This report on the 'Sterilization of Badge using Radiation and Cultivation by Nano-bubble Water for Matsutake Mushroom Cultivation' is belonged to the final report on the preliminary study of the first subject in 2013 for civilian project. This was complimented on the responsible of the Korea Atomic Energy Research Institute for 1{sup st} of June 2013 to 30{sup th} of November 2013. We are going to make sterilization the badge using the gamma ray and supplying the oxygen by nano-bubble oxygen rich water for cultivating the Matsutake Mushroom, instead of the conventional process of sterilization of the badge by hot steam over 120 .deg. C consuming over 8 hours and expensive ventilation system for supplying the fresh air for delivering the oxygen.

  17. Development of quality control procedures for mass produced and released Bactrocera Philippinensis (Diptera: Tephritidae) for sterile insect technique programs

    International Nuclear Information System (INIS)

    Resilva, S.; Obra, G.; Zamora, N.; Gaitan, E.

    2007-01-01

    Quality control procedures for Bactrocera philippinensis Drew and Hancock 1994 (Diptera: Tephritidae) used in sterile insect technique (SIT) programs were established in the mass rearing facility at the Philippine Nuclear Research Institute. Basic studies on pupal irradiation, holding/packaging systems, shipping procedures, longevity, sterility studies, and pupal eye color determination in relation to physiological development at different temperature regimes were investigated. These studies will provide baseline data for the development of quality control protocols for an expansion of B. philippinensis field programs with an SIT component in the future. (author) [es

  18. What do you mean you can't sterilize it? The reusable medical device matrix.

    Science.gov (United States)

    Stephens, Anne; Assang, AnnMarie

    2010-12-01

    begins with proper cleaning and processing of the surgical instruments. Surgical site infections can increase the length of stay and the cost of the patients' hospitalization, as well as increased risk, morbidity and even mortality. 1 Today's patients are far more informed than they were in the past. They can gather information from the internet as well as from television, radio, and print media. This knowledge empowers the patient to expect that their healthcare providers are practicing due diligence. It is the ethical duty and responsibility of nurses to provide safe, competent care while protecting the rights of the patient and being accountable to the professional governing bodies. In other words, we are advocates for both our patients and the healthcare system.2 Using both new and innovative instruments in the OR was, in the past, as simple as a surgeon requesting an instrument, the perioperative nurse ordering the instrument and CPD processing it for use in the OR. That is no longer the case. With a wide range of more complex instrumentation and an increasing focus on sterilization strategies, healthcare facilities have had to adopt a more rigorous approach. There are many challenges in the world of sterile processing. A common one, faced on a regular basis, is the provision of vague, inaccurate reprocessing recommendations from the medical device manufacturer. Canadian centres are not able to meet European standards for reprocessing. European cycles, often referred to as "Fractionated Steam Cycles", are different than the pre-vacuum steam cycles run in Canada.

  19. Radiating sterilization of the venom of snake

    International Nuclear Information System (INIS)

    Abiyev, H.A.; Topchiyeva, Sh.A.; Rustamov, V.R.

    2006-01-01

    Full text: Water solutions of venoms are unstable and they lose toxicity in some day. Snake venoms inactivate under action of some physical factors: the UV-irradiation, x-rays beams. The purpose of the present work was sterilization of venom Vipera lebetina obtusa under influence of small dozes γ-radiations. Object of research was integral venom of adult individuals. Transcaucasian viper, and also the water solutions of venom irradiated with small dozes scale of radiation. An irradiation of venom carried out to radioisotope installation 60NI. For experiment tests of dry venom, and also their water solutions have been taken. Water solutions of venom have been subjected -radiation up to dozes 1.35, 2.7, 4.05, 5.4 kGr simultaneously dry venom of vipers was exposed -radiation before absorption of a doze 5.4 kGr. In comparative aspect action scale of radiation on ultra-violet spectra of absorption of venom was studied. Ultra-violet spectra venom have been taken off on device Specord UV-VIS. In 12 months after an irradiation spectra of absorption of venom have been repeatedly taken off. In spectra irradiated dry and solutions of venom new maxima of absorption have been revealed in the field of 285 nm and 800 nm describing change of toxicity. It is shown, that the increase in absorption of a doze of radiation occurs decrease of intensity of strips of absorption reduction of intensity of absorption.It is revealed at 260 and 300 nm testifying to course of biochemical reactions of separate enzymes zootoxins. It is necessary to note, that at comparison of intensity of absorption of control samples of poison with irradiated up to dozes 1.35 kGr it has not been revealed essential changes. The subsequent increase in a doze scale of radiation up to 2.7, 4.05, 5.4 kGr promotes proportional reduction of intensity of the absorption, describing toxicity of snake venom. At repeated (later 12 months) measurement of the irradiated water solutions of venom are not revealed changes in

  20. Responses to gamma radiation of selected microorganisms in sterile water and bovine muscle

    International Nuclear Information System (INIS)

    Dempster, J.F.; Halls, N.A.

    1986-01-01

    The responses to gamma-radiation of a number of food-associated microorganisms (Staphylococcus aureus, Yersinia enterocolitica, Pseudomonas putrefaciens) were studied in sterile distilled water and sterile bovine muscle slurry. Surviving cells were grown aerobically at room temperature on yeast extract dextrose tryptone agar (PCA, Oxoid). The D 1 0 of the Pseudomonas sp. was 27 Gy in water and the D 1 0 of the Yersinia sp. in water was 32 Gy. In the slurry resistance increased markedly; the Pseudomonas sp. was ten times more resistant (D 1 0 260 Gy) and the Yersinia sp. was seven times more resistant (D 1 0226 Gy). The Staph. aureus was equally sensitive in both systems (author)

  1. Ancient microbes from halite fluid inclusions: optimized surface sterilization and DNA extraction.

    Science.gov (United States)

    Sankaranarayanan, Krithivasan; Timofeeff, Michael N; Spathis, Rita; Lowenstein, Tim K; Lum, J Koji

    2011-01-01

    Fluid inclusions in evaporite minerals (halite, gypsum, etc.) potentially preserve genetic records of microbial diversity and changing environmental conditions of Earth's hydrosphere for nearly one billion years. Here we describe a robust protocol for surface sterilization and retrieval of DNA from fluid inclusions in halite that, unlike previously published methods, guarantees removal of potentially contaminating surface-bound DNA. The protocol involves microscopic visualization of cell structures, deliberate surface contamination followed by surface sterilization with acid and bleach washes, and DNA extraction using Amicon centrifugal filters. Methods were verified on halite crystals of four different ages from Saline Valley, California (modern, 36 ka, 64 ka, and 150 ka), with retrieval of algal and archaeal DNA, and characterization of the algal community using ITS1 sequences. The protocol we developed opens up new avenues for study of ancient microbial ecosystems in fluid inclusions, understanding microbial evolution across geological time, and investigating the antiquity of life on earth and other parts of the solar system.

  2. Radiation sterilization of harmful algae in water

    International Nuclear Information System (INIS)

    Byung Chull An; Jae-Sung Kim; Seung Sik Lee; Shyamkumar Barampuram; Eun Mi Lee; Byung Yeoup Chung

    2007-01-01

    Complete text of publication follows. Objective: Drinking water, water used in food production and for irrigation, water for fish farming, waste water, surface water, and recreational water have been recently recognized as a vector for the transmission of harmful micro-organisms. The human and animal harmful algae is a waterborne risk to public health and economy because the algae are ubiquitous and persistent in water and wastewater, not completely removed by physical-chemical treatment processes, and relatively resistant to chemical disinfection. Gamma and electron beam radiation technology is of growing in the water industry since it was demonstrated that gamma and electron beam radiation is very effective against harmful algae. Materials and Methods: Harmful algae (Scenedesmus quadricauda(Turpin) Brebisson 1835 (AG10003), Chlorella vulgaris Beijerinck 1896 (AG30007) and Chlamydomonas sp. (AG10061)) were distributed from Korean collection for type cultures (KCTC). Strains were cultured aerobically in Allen's medium at 25□ and 300 umol/m2s for 1 week using bioreactor. We investigated the disinfection efficiency of harmful algae irradiated with gamma (0.05 to 10 kGy for 30 min) and electron beam (1 to 19 kGy for 5 sec) rays. Results and Conclusion: We investigated the disinfection efficiency of harmful algae irradiated with gamma and electron beam rays of 50 to 19000 Gy. We established the optimum sterilization condition which use the gamma and electron beam radiation. Gamma ray disinfected harmful algae at 400 Gy for 30 min. Also, electron beam disinfected at 1000 Gy for 5 sec. This alternative disinfection practice had powerful disinfection efficiency. Hence, the multi-barrier approach for drinking water treatment in which a combination of various disinfectants and filtration technologies are applied for removal and inactivation of different microbial pathogens will guarantee a lower risk of microbial contamination.

  3. Proteomic analysis reveals strong mitochondrial involvement in cytoplasmic male sterility of pepper (Capsicum annuum L.).

    Science.gov (United States)

    Guo, Jinju; Wang, Peng; Cheng, Qing; Sun, Limin; Wang, Hongyu; Wang, Yutong; Kao, Lina; Li, Yanan; Qiu, Tuoyu; Yang, Wencai; Shen, Huolin

    2017-09-25

    Although cytoplasmic male sterility (CMS) is widely used for developing pepper hybrids, its molecular mechanism remains unclear. In this study, we used a high-throughput proteomics method called label-free to compare protein abundance across a pepper CMS line (A-line) and its isogenic maintainer line (B-line). Data are available via ProteomeXchange with identifier PXD006104. Approximately 324 differentially abundant protein species were identified and quantified; among which, 47 were up-accumulated and 140 were down-accumulated in the A-line; additionally, 75 and 62 protein species were specifically accumulated in the A-line and B-line, respectively. Protein species involved in pollen exine formation, pyruvate metabolic processes, the tricarboxylic acid cycle, the mitochondrial electron transport chain, and oxidative stress response were observed to be differentially accumulated between A-line and B-line, suggesting their potential roles in the regulation of pepper pollen abortion. Based on our data, we proposed a potential regulatory network for pepper CMS that unifies these processes. Artificial emasculation is a major obstacle in pepper hybrid breeding for its high labor cost and poor seed purity. While the use of cytoplasmic male sterility (CMS) in hybrid system is seriously frustrated because a long time is needed to cultivate male sterility line and its isogenic restore line. Transgenic technology is an effective and rapid method to obtain male sterility lines and its widely application has very important significance in speeding up breeding process in pepper. Although numerous studies have been conducted to select the genes related to male sterility, the molecular mechanism of cytoplasmic male sterility in pepper remains unknown. In this study, we used the high-throughput proteomic method called "label-free", coupled with liquid chromatography-quadrupole mass spectrometry (LC-MS/MS), to perform a novel comparison of expression profiles in a CMS pepper line

  4. Vitrification of human pronuclear oocytes by direct plunging into cooling agent: Non sterile liquid nitrogen vs. sterile liquid air.

    Science.gov (United States)

    Isachenko, Vladimir; Todorov, Plamen; Seisenbayeva, Akerke; Toishibekov, Yerzhan; Isachenko, Evgenia; Rahimi, Gohar; Mallmann, Peter; Foth, Dolores; Merzenich, Markus

    2018-02-01

    In fact, a full sterilization of commercially-produced liquid nitrogen contaminated with different pathogens is not possible. The aim of this study was to compare the viability of human pronuclear oocytes subjected to cooling by direct submerging of open carrier in liquid nitrogen versus submerging in clean liquid air (aseptic system). One- and three-pronuclei stage embryos (n = 444) were cryopreserved by direct plunging into liquid nitrogen (vitrified) in ethylene glycol (15%), dimethylsulphoxide (15%) and 0.2M sucrose. Oocytes were exposed in 20, 33, 50 and 100% vitrification solution for 2, 1 and 1 min, and 30-50 s, respectively at room temperature. Then first part of oocytes (n = 225) were directly plunged into liquid nitrogen, and second part of oocytes (n = 219) into liquid air. Oocytes were thawed rapidly at a speed of 20,000 °C/min and then subsequently were placed into a graded series of sucrose solutions (0.5, 0.25, 0.12 and 0.06M) at 2.5 min intervals and cultured in vitro for 3 days. In both groups, the rate of high-quality embryos (Grade 6A: 6 blastomeres, no fragmentation; Grade 8A: 8 blastomeres, no fragmentation; Grade 8A compacting: 8 blastomeres, beginning of compacting) was noted. The rates of high-quality embryos developed from one-pronuclear oocytes vitrified by cooling in liquid nitrogen and liquid air were: 39.4% ± 0.6 and 38.7% ± 0.8, respectively (P > 0.1). These rates for three-pronuclear oocytes were: 45.8 ± 0.8% and 52.0 ± 0.7%, respectively (P liquid air (aseptic system) is a good alternative for using of not sterile liquid nitrogen. Copyright © 2017. Published by Elsevier Inc.

  5. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: An in vitro study

    Directory of Open Access Journals (Sweden)

    Venkatasubramanian R

    2010-03-01

    Full Text Available Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  6. Reliability of Laparoscopic Compared With Hysteroscopic Sterilization at One Year: A Decision Analysis

    Science.gov (United States)

    Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.

    2011-01-01

    OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842

  7. Prospects for radiation sterilization of medical products in Egypt

    International Nuclear Information System (INIS)

    Roushdy, H.M.

    1975-01-01

    The pharmaceutical industry in Egypt is continually expanding its activity and each year marks new accomplishments and additions which enable the companies to apply the most modern scientific means in the production of pharmaceutical preparations and consequently to improve their market potentialities. The certainty of expansion and the possibility of increasing exports of sterilized medical products, particularly to Arab and African countries, indicate a need for a gamma-sterilization plant. This technology permits the introduction of the latest practices with regard to used disposables, thus greatly reducing the chances of cross-contamination which usually results in serious complications enhanced by local environmental conditions. This paper reviews the current state and future prospects for radiation sterilization of medical products and biological tissues in connection with other related industrial radiation processings. Moreover, the paper reviews the Egyptian scientific and technical experience with irradiation facilities and the parameters underlying the choice of Egypt's first industrial gamma and electron-beam irradiators designed for more than a single-purpose use, with hygienic measures taken to avoid biological contamination of sterilized medical packages throughout the sterilization process. In addition, the paper deals with the policy set up for establishing the Egyptian National Centre for Radiation Technology with a view to introducing irradiation techniques in the sterilization of medical products, and to improving the properties and increasing the competitiveness of Egyptian fabrics. Apart from medical sterilization, certain industrial processes have been mentioned to show how a multi-purpose irradiation facility may be utilized in a developing country to justify significantly the large investment required. (author)

  8. Multiple matings among glossina and the sterile male technique

    International Nuclear Information System (INIS)

    Pinhao, R.C.

    1980-01-01

    The fact that multiple matings are a common phenomenon among glossina turns the sterile male technique into a competition not between adult insects but between two types of sperm, and the proportion of females inseminated with the one or the other is given by the binomial (p+q)sup(n), where p is the percentage of normal males, q the percentage of sterile males and n the average number of matings per female. However, multiple matings cannot damage the effectiveness of the technique unless two conditions are present either separately or simultaneously: precocious death of the spermatozoa and reduced inseminating potential among the sterile males. Study of the factors which can alter the inseminating potential is thus important for those who wish to use the sterile male technique. These factors are of three kinds: factors connected with quality, with quantity and with availability. The first are associated with the nature and intensity of the alterations brought about in the spermatozoa by the sterilizing agent, the second with possible variations in the amount of sperm reaching the spermotheca, the third with the behaviour of the sterile males in the nature - that is, the question whether sterilization has a favourable or unfavourable influence on their chances of mating with wild females. The author describes his observations of the quantity of sperm produced by Glossina morsitans submorsitans males from the colony reared at the Institute for Tropical Hygiene and Medicine in Lisbon, compares them with the observations of other authors and discusses their practical significance. Specific research is suggested. Advantages from assessing the behaviour of colonies not by female productivity but by male inseminating potential, and appropriate laboratory techniques

  9. Temperature Effects on Free Radicals in Gamma-sterilized Beef

    Science.gov (United States)

    Pramanik, S. I.; Jahan, M. S.

    1999-11-01

    Gamma irradiation has become the method of choice for sterilizing frozen meat and their products to reduce levels of food-borne pathogens and to extend shelf life. In this report we have employed ESR technique for detection of free radicals in sterilized and non-sterilized dry beef without bone. We have also determined the heating effects on free radicals at temperatures 176^°C and 250^°C. Meat samples were dried in a food dehydrator at 60^°C and were packaged in dry N_2. They were then sterilized by γ-irradiation (2.5 MRad), ground into powder, and placed in ESR sample tubes. Non-sterilized powder samples were used as control. While all powder samples, sterilized or not, produced a broad single line in the ESR spectra with (Δ H_pp ~ 9 G) and g = 2.013, the radical concentration in the sterilized samples increased by a factor of five. Heat treatment at 176^°C produced similar radicals. But, when samples were heated 250^°C different radical species were formed which are characterized by narrow width (Δ H_pp ~ 6 G) and lower g-value (g =2.010). In contrast with previous work, where free radicals in chicken bones were reduced by heating [1], we observed an increase in concentration. Results of structural analyses of the radicals will be presented. Ref.[1]: Radiat. Phys. Chem., 49, 477-481, 1997. Work supported by Grants from the University of Memphis

  10. Atmospheric Pressure Plasma Induced Sterilization and Chemical Neutralization

    Science.gov (United States)

    Garate, Eusebio; Evans, Kirk; Gornostaeva, Olga; Alexeff, Igor; Lock Kang, Weng; Wood, Thomas K.

    1998-11-01

    We are studying chemical neutralization and surface decontamination using atmospheric pressure plasma discharges. The plasma is produced by corona discharge from an array of pins and a ground plane. The array is constructed so that various gases, like argon or helium, can be flowed past the pins where the discharge is initiated. The pin array can be biased using either DC, AC or pulsed discharges. Results indicate that the atmospheric plasma is effective in sterilizing surfaces with biological contaminants like E-coli and bacillus subtilus cells. Exposure times of less than four minutes in an air plasma result in a decrease in live colony counts by six orders of magnitude. Greater exposure times result in a decrease of live colony counts of up to ten orders of magnitude. The atmospheric pressure discharge is also effective in decomposing organic phosphate compounds that are simulants for chemical warfare agents. Details of the decomposition chemistry, by-product formation, and electrical energy consumption of the system will be discussed.

  11. [Preliminary Study of Lonicera hypoglauca on Germination Conditions of Sand Culture Seeds and Sterilization Method of Sand Culture Seedling Sterilization].

    Science.gov (United States)

    Tan, Mu-xiu; Zeng, Wen-wen; Wei, Peng-xiao; Mo, Qiao-cheng; Pu, Zu-ning; Cen, Xiu-fen; Shi, Feng-hua

    2015-05-01

    To explore the germination conditions of Lonicera hypoglauca sand culture seeds and the effects of sand culture seedlings sterilization. 0.1% HgCl2 with different sterilization time, different illumination time and temperature culture condition were adopted to study the germination conditions of sand culture seeds. Different sterilization treatments and different hardening-seedling days were used to test the sterilization effect of sand culture seedlings. The sterilization effect of the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min on Lonicera hypoglauca seeds was the optimum,with the average pollution rate of 15.56%, and the average germination rate reached 51.11%. The combination of varied temperature-room temperature under light for 12 h/d was the best, with the average germination rate peaked at 75.49%, and the average germination potential reached 68.36%. The treatment of detergent liquor scrub-tap water wash on the part above the hypocotyl, which was sand cultured under the opening condition and had no root, showed the best sterilization effect, with the average pollution rate was zero, and the average survival rate peaked at 100.00%. The sterilization effect of sand culture seedlings, which was disinfected after cleaning by detergent liquor scrub-tap water wash after hardening-seeding for 30 days, was the best, with the average pollution rate of 50.00%, and the average survival rate of 100.00%. The best sterilization effect is the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min; Lighting for 12 h/d of varied temperature-room temperature is regarded as the optimum culture condition. The treatment of detergent liquor scrub-tap water wash treatment on the part above the hypocotyl,which is sand cultured under the opening condition and had no root, shows the best sterilization effect. For the sand culture seedlings, before inoculated in subculture medium, should be hardening-seedling for some days and sterilized after detergent liquor scrub-tap water wash.

  12. Vasectomy occlusion techniques for male sterilization.

    Science.gov (United States)

    Cook, L A; Vliet, H; Pun, A; Gallo, M F

    2004-01-01

    Vasectomy is an increasingly popular and effective family planning method. A variety of vasectomy techniques are used worldwide including various vas occlusion techniques (excision and ligation, thermal or electrocautery, and mechanical and chemical occlusion methods), vas irrigation and fascial interposition. Vasectomy guidelines largely rely on information from observational studies. Ideally, the choice of vasectomy techniques should be based on the best available evidence from randomized controlled trials. The objective of this review was to compare the effectiveness, safety, acceptability and costs of vasectomy techniques for male sterilization. We searched the computerized databases the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Popline and LILACS. In addition, we searched the reference lists of relevant articles and book chapters. We included randomized controlled trials and controlled clinical trials comparing vasectomy techniques. We assessed all titles and abstracts located in the literature searches and two reviewers independently extracted articles identified for inclusion. Data were presented in the text of the review. Outcome measures include contraceptive efficacy, safety, discontinuation, and acceptability. Two trials compared vas occlusion with clips versus a conventional vasectomy technique; both were of poor quality. Neither trial found a difference between the two groups with regard to the primary outcome of failure to reach azoospermia. Four trials examined vas irrigation: three compared water irrigation with no irrigation and one compared water irrigation with euflavine. All of the trials were of poor quality. None of the trials found a significant difference between the groups with respect to the primary outcome of time to azoospermia. However, one trial found that the median number of ejaculations to azoospermia was significantly lower in the euflavine group compared to the water irrigation group. The one trial

  13. A preliminary evaluation of a reusable digital sterilization indicator prototype.

    Science.gov (United States)

    Puttaiah, R; Griggs, J; D'Onofrio, M

    2014-09-01

    Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of sterilizers. Data loggers or independent digital parametric indicators are innovative devices that provide more information than various classes chemical indicators. In this study we evaluated a prototype of an independent digital parametric indicator's use in autoclaves. The purpose of this study was to evaluate the performance of an independent digital indicator/data logger prototype (DS1922F) that could be used for multiple cycles within an autoclave.MG Materials and methods: Three batches of the DS1922F (150 samples) were used in this study that was conducted in a series. The first batch was challenged with 300 sterilization cycles within an autoclave and the data loggers evaluated to study failures and the reason for failure, make corrections and improve the prototype design. After changes made based on studying the first batch, the second batch of the prototype (150 samples) were challenged once again with 300 sterilization cycles within an autoclave and failure studied again in further improvement of the prototype. The final batch (3rd batch) of the prototype (150 samples) was challenged again but with 600 cycles to see how long they would last. Kaplan-Meier survival analysis analyses of all three batches was conducted (α = 0.05) and failed samples qualitatively studied in understanding the variables involved in the failure of the prototype, and in improving quality. Each tested batch provided crucial information on device failure and helped in improvement of the prototype. Mean lifetime survival of the final batch (Batch 3) of prototype was 498 (480, 516) sterilization cycles

  14. Sterile Neutrino Searches in MiniBooNE and MicroBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Ignarra, Christina M. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2014-09-01

    Tension among recent short baseline neutrino experiments has pointed toward the possible need for the addition of one or more sterile (non-interacting) neutrino states into the existing neutrino oscillation framework. This thesis first presents the motivation for sterile neutrino models by describing the short-baseline anomalies that can be addressed with them. This is followed by a discussion of the phenomenology of these models. The MiniBooNE experiment and results are then described in detail, particularly the most recent antineutrino analysis. This will be followed by a discussion of global fits to world data, including the anomalous data sets. Lastly, future experiments will be addressed, especially focusing on the MicroBooNE experiment and light collection studies. In particular, understanding the degradation source of TPB, designing the TPB-coated plates for MicroBooNE and developing lightguide collection systems will be discussed. We find an excess of events in the MiniBooNE antineutrino mode results consistent with the LSND anomaly, but one that has a different energy dependence than the low-energy excess reported in neutrino mode. This disagreement creates tension within global fits which include up to three sterile neutrinos. The low-energy excess will be addressed by the MicroBooNE experiment, which is expected to start taking data in early 2015. Tension among existing experiments calls for additional, more decisive future experiments.

  15. Sterile Neutrino Searches in MiniBooNE and MicroBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Ignarra, Christina M. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2014-09-01

    Tension among recent short baseline neutrino experiments has pointed toward the possible need for the addition of one or more sterile (non-interacting) neutrino states into the existing neutrino oscillation framework. This thesis fi rst presents the motivation for sterile neutrino models by describing the short-baseline anomalies that can be addressed with them. This is followed by a discussion of the phenomenology of these models. The MiniBooNE experiment and results are then described in detail, particularly the most recent antineutrino analysis. This will be followed by a discussion of global fits to world data, including the anomalous data sets. Lastly, future experiments will be addressed, especially focusing on the MicroBooNE experiment and light collection studies. In particular, understanding the degradation source of TPB, designing the TPB-coated plates for MicroBooNE and developing lightguide collection systems will be discussed. We find an excess of events in the MiniBooNE antineutrino mode results consistent with the LSND anomaly, but one that has a di fferent energy dependence than the low-energy excess reported in neutrino mode. This disagreement creates tension within global fi ts which include up to three sterile neutrinos. The low-energy excess will be addressed by the MicroBooNE experiment, which is expected to start taking data in early 2015. Tension among existing experiments calls for additional, more decisive future experiments.

  16. A Novel Technique for Sterilization Using a Power Self-Regulated Single-Mode Microwave Cavity.

    Science.gov (United States)

    Reverte-Ors, Juan D; Pedreño-Molina, Juan L; Fernández, Pablo S; Lozano-Guerrero, Antonio J; Periago, Paula M; Díaz-Morcillo, Alejandro

    2017-06-07

    In this paper, a novel technique to achieve precise temperatures in food sterilization has been proposed. An accurate temperature profile is needed in order to reach a commitment between the total removal of pathogens inside the product and the preservation of nutritional and organoleptic characteristics. The minimal variation of the target temperature in the sample by means of a monitoring and control software platform, allowing temperature stabilization over 100 °C, is the main goal of this work. A cylindrical microwave oven, under pressure conditions and continuous control of the microwave supply power as function of the final temperature inside the sample, has been designed and developed with conditions of single-mode resonance. The uniform heating in the product is achieved by means of sample movement and the self-regulated power control using the measured temperature. Finally, for testing the sterilization of food with this technology, specific biological validation based on Bacillus cereus as a biosensor of heat inactivation has been incorporated as a distribution along the sample in the experimental process to measure the colony-forming units (CFUs) for different food samples (laboratory medium, soup, or fish-based animal by-products). The obtained results allow the validation of this new technology for food sterilization with precise control of the microwave system to ensure the uniform elimination of pathogens using high temperatures.

  17. A Novel Technique for Sterilization Using a Power Self-Regulated Single-Mode Microwave Cavity

    Directory of Open Access Journals (Sweden)

    Juan D. Reverte-Ors

    2017-06-01

    Full Text Available In this paper, a novel technique to achieve precise temperatures in food sterilization has been proposed. An accurate temperature profile is needed in order to reach a commitment between the total removal of pathogens inside the product and the preservation of nutritional and organoleptic characteristics. The minimal variation of the target temperature in the sample by means of a monitoring and control software platform, allowing temperature stabilization over 100 °C, is the main goal of this work. A cylindrical microwave oven, under pressure conditions and continuous control of the microwave supply power as function of the final temperature inside the sample, has been designed and developed with conditions of single-mode resonance. The uniform heating in the product is achieved by means of sample movement and the self-regulated power control using the measured temperature. Finally, for testing the sterilization of food with this technology, specific biological validation based on Bacillus cereus as a biosensor of heat inactivation has been incorporated as a distribution along the sample in the experimental process to measure the colony-forming units (CFUs for different food samples (laboratory medium, soup, or fish-based animal by-products. The obtained results allow the validation of this new technology for food sterilization with precise control of the microwave system to ensure the uniform elimination of pathogens using high temperatures.

  18. Hybrid male sterility in Mimulus (Phrymaceae) is associated with a geographically restricted mitochondrial rearrangement.

    Science.gov (United States)

    Case, Andrea L; Willis, John H

    2008-05-01

    Cytoplasmic male sterility (CMS) and nuclear fertility restoration (Rf) involves intergenomic coevolution. Although male-sterile phenotypes are rarely expressed in natural populations of angiosperms, CMS genes are thought to be common. The evolutionary dynamics of CMS/Rf systems are poorly understood, leaving gaps in our understanding of mechanisms and consequences of cytonuclear interactions. We characterized the molecular basis and geographic distribution of a CMS gene in Mimulus guttatus. We used outcrossing M. guttatus (with CMS and Rf) to self-fertilizing M. nasutus (lacking CMS and Rf) to generate hybrids segregating for CMS. Mitochondrial transcripts containing an essential gene (nad6) were perfectly associated with male sterility. The CMS mitotype was completely absent in M. nasutus, present in all genotypes collected from the original collection site, but in only two individuals from 34 other M. guttatus populations. This pattern suggests that the CMS likely originated at a single locality, spread to fixation within the population, but has not spread to other populations, indicating possible ecological or genetic constraints on dispersal of this CMS mitotype between populations. Extreme localization may be characteristic of CMS in hermaphroditic species, in contrast to geographically widespread mitotypes commonly found in gynodioecious species, and could directly contribute to hybrid incompatibilities in nature.

  19. Asymmetry and polymorphism of hybrid male sterility during the early stages of speciation in house mice.

    Science.gov (United States)

    Good, Jeffrey M; Handel, Mary Ann; Nachman, Michael W

    2008-01-01

    House mice offer a powerful system for dissecting the genetic basis of phenotypes that isolate species in the early stages of speciation. We used a series of reciprocal crosses between wild-derived strains of Mus musculus and M. domesticus to examine F(1) hybrid male sterility, one of the primary phenotypes thought to isolate these species. We report four main results. First, we found significantly smaller testes and fewer sperm in hybrid male progeny of most crosses. Second, in some crosses hybrid male sterility was asymmetric and depended on the species origin of the X chromosome. These observations confirm and extend previous findings, underscoring the central role that the M. musculus X chromosome plays in reproductive isolation. Third, comparisons among reciprocal crosses revealed polymorphism at one or more hybrid incompatibilities within M. musculus. Fourth, the spermatogenic phenotype of this polymorphic interaction appears distinct from previously described hybrid incompatibilities between these species. These data build on previous studies of speciation in house mice and show that the genetic basis of hybrid male sterility is fairly complex, even at this early stage of divergence.

  20. Dark radiation sterile neutrino candidates after Planck data

    Energy Technology Data Exchange (ETDEWEB)

    Valentino, Eleonora Di; Melchiorri, Alessandro [Physics Department and INFN, Università di Roma ' ' La Sapienza' ' , Ple Aldo Moro 2, 00185, Rome (Italy); Mena, Olga, E-mail: eleonora.divalentino@roma1.infn.it, E-mail: alessandro.melchiorri@roma1.infn.it, E-mail: omena@ific.uv.es [IFIC, Universidad de Valencia-CSIC, 46071, Valencia (Spain)

    2013-11-01

    Recent Cosmic Microwave Background (CMB) results from the Planck satellite, combined with previous CMB data and Hubble constant measurements from the Hubble Space Telescope, provide a constraint on the effective number of relativistic degrees of freedom 3.62{sup +0.50}{sub −0.48} at 95% CL. New Planck data provide a unique opportunity to place limits on models containing relativistic species at the decoupling epoch. We present here the bounds on sterile neutrino models combining Planck data with galaxy clustering information. Assuming N{sub eff} active plus sterile massive neutrino species, in the case of a Planck+WP+HighL+HST analysis we find m{sub ν,} {sub sterile}{sup eff} < 0.36 eV and 3.14 < N{sub eff} < 4.15 at 95% CL, while using Planck+WP+HighL data in combination with the full shape of the galaxy power spectrum from the Baryon Oscillation Spectroscopic Survey BOSS Data Relase 9 measurements, we find that 3.30 < N{sub eff} < 4.43 and m{sub ν,} {sub sterile}{sup eff} < 0.33 eV both at 95% CL with the three active neutrinos having the minimum mass allowed in the normal hierarchy scheme, i.e. ∑m{sub ν} ∼ 0.06 eV. These values compromise the viability of the (3+2) massive sterile neutrino models for the parameter region indicated by global fits of neutrino oscillation data. Within the (3+1) massive sterile neutrino scenario, we find m{sub ν,} {sub sterile}{sup eff} < 0.34 eV at 95% CL. While the existence of one extra sterile massive neutrino state is compatible with current oscillation data, the values for the sterile neutrino mass preferred by oscillation analyses are significantly higher than the current cosmological bound. We review as well the bounds on extended dark sectors with additional light species based on the latest Planck CMB observations.

  1. Linezolid Dose That Maximizes Sterilizing Effect While Minimizing Toxicity and Resistance Emergence for Tuberculosis.

    Science.gov (United States)

    Srivastava, Shashikant; Magombedze, Gesham; Koeuth, Thearith; Sherman, Carleton; Pasipanodya, Jotam G; Raj, Prithvi; Wakeland, Edward; Deshpande, Devyani; Gumbo, Tawanda

    2017-08-01

    Linezolid has an excellent sterilizing effect in tuberculosis patients but high adverse event rates. The dose that would maximize efficacy and minimize toxicity is unknown. We performed linezolid dose-effect and dose-scheduling studies in the hollow fiber system model of tuberculosis (HFS-TB) for sterilizing effect. HFS-TB units were treated with several doses to mimic human-like linezolid intrapulmonary pharmacokinetics and repetitively sampled for drug concentration, total bacterial burden, linezolid-resistant subpopulations, and RNA sequencing over 2 months. Linezolid-resistant isolates underwent whole-genome sequencing. The expression of genes encoding efflux pumps in the first 1 to 2 weeks revealed the same exposure-response patterns as the linezolid-resistant subpopulation. Linezolid-resistant isolates from the 2nd month of therapy revealed mutations in several efflux pump/transporter genes and a LuxR-family transcriptional regulator. Linezolid sterilizing effect was linked to the ratio of unbound 0- to 24-h area under the concentration-time curve (AUC 0-24 ) to MIC. Optimal microbial kill was achieved at an AUC 0-24 /MIC ratio of 119. The optimal sterilizing effect dose for clinical use was identified using Monte Carlo simulations. Clinical doses of 300 and 600 mg/day (or double the dose every other day) achieved this target in 87% and >99% of 10,000 patients, respectively. The susceptibility breakpoint identified was 2 mg/liter. The simulations identified that a 300-mg/day dose did not achieve AUC 0-24 s associated with linezolid toxicity, while 600 mg/day achieved those AUC 0-24 s in linezolid dose of 300 mg/day performed well and should be compared to 600 mg/day or 1,200 mg every other day in clinical trials. Copyright © 2017 Srivastava et al.

  2. Assessing anti-T. cruzi candidates in vitro for sterile cidality

    Directory of Open Access Journals (Sweden)

    Monica Cal

    2016-12-01

    Full Text Available Total clearance of the T. cruzi infection – referred to herein as “sterile cure” – seems to be a critical prerequisite for new drug candidates for Chagas disease, ensuring long-term beneficial effects for patients in the chronic indeterminate stage. This requirement is notably supported by the recent findings of clinical studies involving posaconazole and fosravuconazole, where the majority of patients treated eventually relapsed after an apparent clearance of parasitaemia at the end of treatment. We have adapted an in vitro system to predict the ability of a compound to deliver sterile cure. It relies on mouse peritoneal macrophages as host cells for Trypanosoma cruzi amastigotes. The macrophages do not proliferate, allowing for long-term testing and wash-out experiments. Giemsa staining followed by microscopy provides a highly sensitive and specific tool to quantify the numbers of infected host cells. Combining macrophages as host cells and Giemsa staining as the read-out, we demonstrate that posaconazole and other CYP51 inhibitors are unable to achieve complete clearance of an established T. cruzi infection in vitro in spite of the fact that these compounds are active at significantly lower concentrations than the reference drugs benznidazole and nifurtimox. Indeed, a few macrophages remained infected after 96 h of drug incubation in the presence of CYP51 inhibitors–albeit at a very low parasite load. These residual T. cruzi amastigotes were shown to be viable and infective, as demonstrated by wash-out experiments. We advocate characterizing any new anti-T. cruzi early stage candidates for sterile cidality early in the discovery cascade, as a surrogate for delivery of sterile cure in vivo.

  3. Mechanisms of Transmission Ratio Distortion at Hybrid Sterility Loci Within and Between Mimulus Species

    Directory of Open Access Journals (Sweden)

    Rachel E. Kerwin

    2017-11-01

    Full Text Available Hybrid incompatibilities are a common correlate of genomic divergence and a potentially important contributor to reproductive isolation. However, we do not yet have a detailed understanding of how hybrid incompatibility loci function and evolve within their native species, or why they are dysfunctional in hybrids. Here, we explore these issues for a well-studied, two-locus hybrid incompatibility between hybrid male sterility 1 (hms1 and hybrid male sterility 2 (hms2 in the closely related yellow monkeyflower species Mimulus guttatus and M. nasutus. By performing reciprocal backcrosses with introgression lines (ILs, we find evidence for gametic expression of the hms1-hms2 incompatibility. Surprisingly, however, hybrid transmission ratios at hms1 do not reflect this incompatibility, suggesting that additional mechanisms counteract the effects of gametic sterility. Indeed, our backcross experiment shows hybrid transmission bias toward M. guttatus through both pollen and ovules, an effect that is particularly strong when hms2 is homozygous for M. nasutus alleles. In contrast, we find little evidence for hms1 transmission bias in crosses within M. guttatus, providing no indication of selfish evolution at this locus. Although we do not yet have sufficient genetic resolution to determine if hybrid sterility and transmission ratio distortion (TRD map to the same loci, our preliminary fine-mapping uncovers a genetically independent hybrid lethality system involving at least two loci linked to hms1. This fine-scale dissection of TRD at hms1 and hms2 provides insight into genomic differentiation between closely related Mimulus species and reveals multiple mechanisms of hybrid dysfunction.

  4. Mechanisms of Transmission Ratio Distortion at Hybrid Sterility Loci Within and Between Mimulus Species.

    Science.gov (United States)

    Kerwin, Rachel E; Sweigart, Andrea L

    2017-11-06

    Hybrid incompatibilities are a common correlate of genomic divergence and a potentially important contributor to reproductive isolation. However, we do not yet have a detailed understanding of how hybrid incompatibility loci function and evolve within their native species, or why they are dysfunctional in hybrids. Here, we explore these issues for a well-studied, two-locus hybrid incompatibility between hybrid male sterility 1 ( hms1 ) and hybrid male sterility 2 ( hms2 ) in the closely related yellow monkeyflower species Mimulus guttatus and M. nasutus By performing reciprocal backcrosses with introgression lines (ILs), we find evidence for gametic expression of the hms1-hms2 incompatibility. Surprisingly, however, hybrid transmission ratios at hms1 do not reflect this incompatibility, suggesting that additional mechanisms counteract the effects of gametic sterility. Indeed, our backcross experiment shows hybrid transmission bias toward M. guttatus through both pollen and ovules, an effect that is particularly strong when hms2 is homozygous for M. nasutus alleles. In contrast, we find little evidence for hms1 transmission bias in crosses within M. guttatus , providing no indication of selfish evolution at this locus. Although we do not yet have sufficient genetic resolution to determine if hybrid sterility and transmission ratio distortion (TRD) map to the same loci, our preliminary fine-mapping uncovers a genetically independent hybrid lethality system involving at least two loci linked to hms1 This fine-scale dissection of TRD at hms1 and hms2 provides insight into genomic differentiation between closely related Mimulus species and reveals multiple mechanisms of hybrid dysfunction. Copyright © 2017 Kerwin and Sweigart.

  5. Mating competitiveness of sterile genetic sexing strain males (GAMA) under laboratory and semi-field conditions: Steps towards the use of the Sterile Insect Technique to control the major malaria vector Anopheles arabiensis in South Africa.

    Science.gov (United States)

    Munhenga, Givemore; Brooke, Basil D; Gilles, Jeremie R L; Slabbert, Kobus; Kemp, Alan; Dandalo, Leonard C; Wood, Oliver R; Lobb, Leanne N; Govender, Danny; Renke, Marius; Koekemoer, Lizette L

    2016-03-02

    Anopheles arabiensis Patton is primarily responsible for malaria transmission in South Africa after successful suppression of other major vector species using indoor spraying of residual insecticides. Control of An. arabiensis using current insecticide based approaches is proving difficult owing to the development of insecticide resistance, and variable feeding and resting behaviours. The use of the sterile insect technique as an area-wide integrated pest management system to supplement the control of An. arabiensis was proposed for South Africa and is currently under investigation. The success of this technique is dependent on the ability of laboratory-reared sterile males to compete with wild males for mates. As part of the research and development of the SIT technique for use against An. arabiensis in South Africa, radio-sensitivity and mating competitiveness of a local An. arabiensis sexing strain were assessed. The optimal irradiation dose inducing male sterility without compromising mating vigour was tested using Cobalt 60 irradiation doses ranging from 70-100 Gy. Relative mating competitiveness of sterile laboratory-reared males (GAMA strain) compared to fertile wild-type males (AMAL strain) for virgin wild-type females (AMAL) was investigated under laboratory and semi-field conditions using large outdoor cages. Three different sterile male to fertile male to wild-type female ratios were evaluated [1:1:1, 5:1:1 and 10:1:1 (sterile males: fertile, wild-type males: fertile, wild-type females)]. Irradiation at the doses tested did not affect adult emergence but had a moderate effect on adult survivorship and mating vigour. A dose of 75 Gy was selected for the competitiveness assays. Mating competitiveness experiments showed that irradiated GAMA male mosquitoes are a third as competitive as their fertile AMAL counterparts under semi-field conditions. However, they were not as competitive under laboratory conditions. An inundative ratio of 10:1 induced the

  6. Sterile insect technique: new technology to control fruit flies, Ceratitis capitata, in the Lower Basin of the Sao Francisco Valley

    International Nuclear Information System (INIS)

    Paranhos, Beatriz Aguiar Jordao; Barbosa, Flavia Rabelo; Nascimento, Antonio Souza do; Viana, Rodrigo; Malavasi, Aldo; Sampaio, Raimundo; Walder, Julio Marcos Melges

    2008-01-01

    The SIT is the creation, on a large scale, the insect-pest to be controlled and weekly release of these insects sterilized in the field.The sterile insects copulate with the wild, but do not generate descendants. The basic premises for the use of SIT in insect control are: the reproduction is through sexual intercourse, the female copulate preferably only once there is ease of creation of the plague in industrial scale in artificial diet. The efficiency of the SIT may be greater when only the males are released in the field because they increase the probability of copulating with wild females only, with reductions in the cost of production and release. In the case of fruit-flies, sterile females continue doing puncture in the fruits, which decreases the quality for export. To be able to release only males in the field, in 1980s, was developed a mutant strain, whose females emerge from pupae white, thus being able to discard the white ones, keeping the pupae Brown for the release of sterile males. Ten years after, to save on the industrial scale production system, was obtained a mutant whose females possess lethal temperature sensitivity of 34 deg C, still in the embryo stage. Then the eggs are placed on artificial diet, and when they arrive at the pupa stage, they are all brown and males. Forty-eight to 24 hours before the emergence of adults, the pupae are painted with fluorescent powder paint, bagged and irradiated with gamma radiation of 95Gy of Co-60 or X-ray. As soon as the males emerge, are marked with fluorescent ink and when they reach 3 to 5 days old, are released into the field. Thus, when monitoring is done in Jackson traps in the field, it is possible to distinguish wild male sterile under black light or epifluorescence microscope with males, because the sterile are fluorescent. On application of the SIT to Moscamed, sterile males are released in the field must display good dispersibility, good survival and good sexual performance. The efficiency and

  7. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  8. Sterilization of microbes by using various plasma jets

    Energy Technology Data Exchange (ETDEWEB)

    Uhm, Han S.; Choi, Eun H.; Cho, Guang S. [Kwangwoon University, Seoul (Korea, Republic of); Hong, Yong C. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2012-03-15

    Sterilization of various microbes was carried out by using several plasma jets. Argon plasma jets penetrate deep into ambient air and create a path for oxygen radicals to sterilize microbes including spores. A sterilization experiment with bacterial endospores indicates that an argon-oxygen plasma jet very effectively kills endospores of Bacillus atrophaeus (ATCC 9372), thereby demonstrating its capability to clean surfaces and its usefulness for reinstating contaminated equipment as free from toxic biological agents. The key element of the sterilization is oxygen radicals. The penciltype configuration produces a long, cold plasma jet capable of reaching 3.5 cm and having various excited plasma species shown through the optical emission spectrum. Operation of an air plasma jet at 2 W in a pencil-type electrode provides an excellent opportunity for sterilization of microbes. An electron microscope was used to observe the effects of the plasma on bacterial cell morphology. Transmission electron micrographs showed morphological changes in E. coli cells treated with an atmospheric plasma at 75 W for 2 min. The treated cells had severe cytoplasmic deformations and leakage of bacterial chromosome. The chromosomal DNA was either attached to the bacterial cells or released freely into the surrounding medium. The results clearly explain the loss of viability of bacterial cells after plasma treatment.

  9. Research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang; Ouyang Qiongli

    2010-01-01

    Radiation sterilization is widely applied in food processing, pharmaceutical manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. There are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the restrictions of capacity and inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  10. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    International Nuclear Information System (INIS)

    Huang, Junting

    2015-01-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states v e , v μ and v τ . In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ 24 in the range of 10 -2 eV 2 < Δm 43 2 < 1 eV 2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  11. In vitro sterilization technique on embryo of black Toraja rice

    Science.gov (United States)

    Haring, F.; Riadi, M.; Rafiuddin; Sjahril, R.; Muchlis, A. R.

    2018-05-01

    Toraja black rice has a high anthocyanin content, a water-soluble pigments, with antioxidant activity. Toraja black rice has a variety of seeds colour in one panicles such as full black (the outside and inside the rice), medium black (the outside and slightly inside rice) and a little black (only the outside of rice). Embryo culture in vitro is one way to grow plants in sterile conditions. The presence of contamination and the death of the embryo require in vitro embryo culture. The sterilization technique is a very important first step to eliminate contamination and the death of embryos. This research aims to determine the right material composition for sterilization of black rice’s embryo. The experiment was done by growing black rice on half strength MS media with the treatment of three method of sterilization, i.e.: S1 (70% alcohol for 5 minutes, 3% and 2% Chlorox each for 10 minutes,), S2 (70% alcohol for 3 minutes, 2% Clorox for 10 minutes) and S3 (70% alcohol for 3 minutes and 1% Clorox for 15 minutes). The materials used are rice seedlings that have been cut in two and opened the pericarp of paddy grain, leaving a piece of rice that has a complete embryo. The best sterilization for Toraja black rice embryo culture was using the S3 composition. Best germination was seen on the seeds with full and medium black color.

  12. Electron beam sterilization of water discharged from sewage

    International Nuclear Information System (INIS)

    Miyata, Teijiro; Arai, Hidehiko; Tokunaga, Okihiro; Machi, Sueo; Kondo, Masaki; Minemura, Takashi; Nakao, Akio; Seike, Yasuhiko.

    1989-01-01

    At present, the water treated at city sewerages is discharged to rivers after the chlorine sterilization, but it was clarified recently that this chlorine treatment produces carcinogenic organic chlorine compounds, and residual chlorine exerts harmful effect to aquatics, therefore, it is desirable to develop the sterilization techniques substituting for chlorine treatment. Already many reports elucidated that irradiation is effective for the sterilization of the water discharged from sewerage. However, as the technical subject for putting radiation process in practical use, the treatment of large quantity was a problem. Recently by the progress of the technology of manufacturing electron accelerators, the equipment with large power output which can treat in large quantity was developed, and it has become applicable also to sewage treatment. Therefore, the authors examined the practicality of electron beam process as the substitute technology for chlorine sterilizaiton. In the case of using electron beam, though the power output of accelerators is large, the flight range of electron beam in water is short. The comparison of the sterilization effect of electron beam with that of Co-60 gamma ray, the effects of water depth, discharged water quality and water velocity on the sterilization effect and so on were experimentally examined. (K.I.)

  13. Search for heavy sterile neutrinos in trileptons at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Claudio O. [Univ. Tecnica Federico Santa Maria, Valparaiso (Chile). CCTVal y Dept. of Physics; Kim, C.S. [Yonsei Univ., Seoul (Korea, Republic of). Dept. of Physics and IPAP; Wang, Kechen [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Chinese Academy of Sciences, Beijing (China). Center for Future High Energy Physics

    2017-03-15

    We present a search strategy for both Dirac and Majorana sterile neutrinos from the purely leptonic decays of W{sup ±}→e{sup ±}e{sup ±}μ{sup -+}ν and μ{sup ±}μ{sup ±}e{sup -+}ν at the 14 TeV LHC. The discovery and exclusion limits for sterile neutrinos are shown using both the Cut-and-Count (CC) and Multi-Variate Analysis (MVA) methods. We also discriminate between Dirac and Majorana sterile neutrinos by exploiting a set of kinematic observables which differ between the Dirac and Majorana cases. We find that the MVA method, compared to the more common CC method, can greatly enhance the discovery and discrimination limits. Two benchmark points with sterile neutrino mass m{sub N}=20 GeV and 50 GeV are tested. For an integrated luminosity of 3000 fb{sup -1}, sterile neutrinos can be found with 5σ significance if heavy-to-light neutrino mixings vertical stroke U{sub Ne} vertical stroke {sup 2}∝ vertical stroke U{sub Nμ} vertical stroke {sup 2}∝10{sup -6}, while Majorana vs. Dirac discrimination can be reached if at least one of the mixings is of order 10{sup -5}.

  14. Population suppression in support of the sterile insect technique

    International Nuclear Information System (INIS)

    Mangan, R.L.

    2005-01-01

    Suppression or eradication of insect pest populations by the release of sterile insects is often dependent on supplementary methods of pest reduction to levels where the target pest population can be overflooded with sterile insects. Population suppression activities take place in advance of, or coincide with, the production of sterile insects. Supplementary methods to remove breeding opportunities, or management methods that prevent access of pests to the hosts, may reduce the population or prevent damage. Insecticides have been used widely in direct applications or applied as baits, in traps, or on specific sites where the pest makes contact or reproduces. As sterile insect release does not kill the pest, adult biting pests or fertile mated females of the pests will continue to attack hosts after the release of sterile insects. Thus supplementary pest suppression programmes and quarantine measures are essential to prevent damage or the spread of disease. Eradication or effective pest management requires that the entire population of the pest be treated, or that the programme apply immigration barriers. When supplementary pest control activities benefit the human population in areas being treated, such as in mosquito or screwworm eradication programmes, these activities are usually acceptable to the public, but when the public receives no direct benefit from supplementary control activities such as in fruit fly programmes, social resistance may develop. (author)

  15. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Junting [Univ. of Texas, Austin, TX (United States)

    2015-05-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states ve, vμ and vτ. In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ24 in the range of 10-2 eV2 < Δm412 < 1 eV2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  16. Search for heavy sterile neutrinos in trileptons at the LHC

    International Nuclear Information System (INIS)

    Dib, Claudio O.; Kim, C.S.; Wang, Kechen; Chinese Academy of Sciences, Beijing

    2017-03-01

    We present a search strategy for both Dirac and Majorana sterile neutrinos from the purely leptonic decays of W"±→e"±e"±μ"-"+ν and μ"±μ"±e"-"+ν at the 14 TeV LHC. The discovery and exclusion limits for sterile neutrinos are shown using both the Cut-and-Count (CC) and Multi-Variate Analysis (MVA) methods. We also discriminate between Dirac and Majorana sterile neutrinos by exploiting a set of kinematic observables which differ between the Dirac and Majorana cases. We find that the MVA method, compared to the more common CC method, can greatly enhance the discovery and discrimination limits. Two benchmark points with sterile neutrino mass m_N=20 GeV and 50 GeV are tested. For an integrated luminosity of 3000 fb"-"1, sterile neutrinos can be found with 5σ significance if heavy-to-light neutrino mixings vertical stroke U_N_e vertical stroke "2∝ vertical stroke U_N_μ vertical stroke "2∝10"-"6, while Majorana vs. Dirac discrimination can be reached if at least one of the mixings is of order 10"-"5.

  17. Benchmarking of Sterilizing grade filters with liposome Filtration.

    Science.gov (United States)

    Loewe, Thomas; Mundlamuri, Ramesh; Loewe, Thomas; Mundrigi, Ashok; Handt, Sebastian; Singh, Bhuwan

    2017-12-14

    Cytotoxic drugs can be encapsulated in liposomes vesicles, which act as drug delivery vehicles and reduce the risk of exposure of drug to healthy cells(1). The sterility of such liposome solutions is typically ensured using 0.2μm rated sterilizing grade membranes, but due to the high viscosity and low surface tension of these formulations, they can cause pre-mature blocking and increased risk of bacterial penetration through a 0.2μm sterilizing grade membrane(2). The low surface tension of liposome solutions affects the contact angle with membrane and reduces bubble point leading to bacterial penetration through the membrane. This poses a great challenge to select an appropriate sterilizing grade membrane for a given process and for filter manufacturers to develop a sterilizing grade membrane that specifically addresses these needs. In this study, the influence of different variables that could affect the total throughput and bacterial retention performance of different membranes types on processing of liposome solutions have been evaluated. Based on the results, we conclude that the membrane properties e.g., surface porosity, surface tension, pore size, symmetry/asymmetry, hydrophilicity and liposome properties e.g., composition, lipid size and concentration affect bacterial retention and total throughput capacity. Process parameters such as temperature, pressure and flow should also be optimized to improve process efficiency. Copyright © 2017, Parenteral Drug Association.

  18. Effects of sterile neutrino and extra-dimension on big bang nucleosynthesis

    Science.gov (United States)

    Jang, Dukjae; Kusakabe, Motohiko; Cheoun, Myung-Ki

    2018-04-01

    We study effects of the sterile neutrino in the five-dimensional universe on the big bang nucleosynthesis (BBN). Since the five-dimensional universe model leads to an additional term in the Friedmann equation and the energy density of the sterile neutrino increases the total energy density, this model can affect the primordial abundance via changing the cosmic expansion rate. The energy density of the sterile neutrino can be determined by a rate equation for production of the sterile neutrino. We show that not only the mixing angle and the mass of the sterile neutrino, but also a resonant effect in the oscillation between sterile and active neutrinos is important to determine a relic abundance of the sterile neutrino. In this study, we also investigate how the sterile neutrino in extra-dimensional model can affect the BBN, and constrain the parameters related to the above properties of the sterile neutrino by using the observational primordial abundances of light elements.

  19. Estimation of populations and sterility induction in Anastrepha ludens (Diptera: Tephritidae) fruit flies

    International Nuclear Information System (INIS)

    Flores, Salvador; Montoya, Pablo; Toledo, Jorge; Liedo, Pablo; Enkerlin, Walther

    2015-01-01

    The relationship between different release densities of sterile flies and fly trap captures, expressed as flies per trap per day, in the monitoring of Anastrepha ludens (Loew) populations was evaluated in mango orchards. The induction of sterility in fertile females was evaluated using different ratios of sterile: fertile males under field cage conditions. A direct relationship between recaptured flies and densities of release sterile flies was found. However, trap efficiency, expressed as percentage of recaptured flies, decreased as the density of released flies increased. Sterility induction was positively correlated to the ratio of sterile: fertile flies. A significant difference in egg fertility among treatments was observed. The trajectory of sterility induction slowed down after a sterile: wild ratio of 30:1, which suggests that this ratio could be appropriate in an sterile insect technique program with A. ludens. Sterility induction was greater when only sterile males were released than when releasing both sterile males and females, but the differences were not significant. Our findings contribute to a better interpretation of fly captures obtained from the field trapping networks, and to an improvement in the efficiency of sterile insect technique against A. ludens fruit flies, through the implementation of more rational sterile fly release densities. (author)

  20. Map-based cloning and characterization of Zea mays male sterility33 (ZmMs33) gene, encoding a glycerol-3-phosphate acyltransferase.

    Science.gov (United States)

    Xie, Ke; Wu, Suowei; Li, Ziwen; Zhou, Yan; Zhang, Danfeng; Dong, Zhenying; An, Xueli; Zhu, Taotao; Zhang, Simiao; Liu, Shuangshuang; Li, Jinping; Wan, Xiangyuan

    2018-06-01

    Map-based cloning of maize ms33 gene showed that ZmMs33 encodes a sn-2 glycerol-3-phosphate acyltransferase, the ortholog of rice OsGPAT3, and it is essential for male fertility in maize. Genetic male sterility has been widely studied for its biological significance and commercial value in hybrid seed production. Although many male-sterile mutants have been identified in maize (Zea mays L.), it is likely that most genes that cause male sterility are unknown. Here, we report a recessive genetic male-sterile mutant, male sterility33 (ms33), which displays small, pale yellow anthers, and complete male sterility. Using a map-based cloning approach, maize GRMZM2G070304 was identified as the ms33 gene (ZmMs33). ZmMs33 encodes a novel sn-2 glycerol-3-phosphate acyltransferase (GPAT) in maize. A functional complementation experiment showed that GRMZM2G070304 can rescue the male-sterile phenotype of the ms33-6029 mutant. GRMZM2G070304 was further confirmed to be the ms33 gene via targeted knockouts induced by the clustered regularly interspersed short palindromic repeats (CRISPR)/Cas9 system. ZmMs33 is preferentially expressed in the immature anther from the quartet to early-vacuolate microspore stages and in root tissues at the fifth leaf growth stage. Phylogenetic analysis indicated that ZmMs33 and OsGPAT3 are evolutionarily conserved for anther and pollen development in monocot species. This study reveals that the monocot-specific GPAT3 protein plays an important role in male fertility in maize, and ZmMs33 and mutants in this gene may have value in maize male-sterile line breeding and hybrid seed production.