WorldWideScience

Sample records for sterile cross-clade protection

  1. MVA-based H5N1 vaccine affords cross-clade protection in mice against influenza A/H5N1 viruses at low doses and after single immunization.

    Directory of Open Access Journals (Sweden)

    Joost H C M Kreijtz

    Full Text Available Human infections with highly pathogenic avian influenza viruses of the H5N1 subtype, frequently reported since 2003, result in high morbidity and mortality. It is feared that these viruses become pandemic, therefore the development of safe and effective vaccines is desirable. MVA-based H5N1 vaccines already proved to be effective when two immunizations with high doses were used. Dose-sparing strategies would increase the number of people that can be vaccinated when the amount of vaccine preparations that can be produced is limited. Furthermore, protective immunity is induced ideally after a single immunization. Therefore the minimal requirements for induction of protective immunity with a MVA-based H5N1 vaccine were assessed in mice. To this end, mice were vaccinated once or twice with descending doses of a recombinant MVA expressing the HA gene of influenza virus A/Vietnam/1194/04. The protective efficacy was determined after challenge infection with the homologous clade 1 virus and a heterologous virus derived from clade 2.1, A/Indonesia/5/05 by assessing weight loss, virus replication and histopathological changes. It was concluded that MVA-based vaccines allowed significant dose-sparing and afford cross-clade protection, also after a single immunization, which are favorable properties for an H5N1 vaccine candidate.

  2. A replicating modified vaccinia tiantan strain expressing an avian-derived influenza H5N1 hemagglutinin induce broadly neutralizing antibodies and cross-clade protective immunity in mice.

    Directory of Open Access Journals (Sweden)

    Haixia Xiao

    Full Text Available To combat the possibility of a zoonotic H5N1 pandemic in a timely fashion, it is necessary to develop a vaccine that would confer protection against homologous and heterologous human H5N1 influenza viruses. Using a replicating modified vaccinia virus Tian Tan strain (MVTT as a vaccine vector, we constructed MVTTHA-QH and MVTTHA-AH, which expresses the H5 gene of a goose-derived Qinghai strain A/Bar-headed Goose/Qinghai/1/2005 or human-derived Anhui Strain A/Anhui/1/2005. The immunogenicity profiles of both vaccine candidates were evaluated. Vaccination with MVTTHA-QH induced a significant level of neutralizing antibodies (Nabs against a homologous strain and a wide range of H5N1 pseudoviruses (clades 1, 2.1, 2.2, 2.3.2, and 2.3.4. Neutralization tests (NT and Haemagglutination inhibition (HI antibodies inhibit the live autologous virus as well as a homologous A/Xingjiang/1/2006 and a heterologous A/Vietnam/1194/2004, representing two human isolates from clade 2.2 and clade 1, respectively. Importantly, mice vaccinated with intranasal MVTTHA-QH were completely protected from challenge with lethal dosages of A/Bar-headed Goose/Qinghai/1/2005 and the A/Viet Nam/1194/2004, respectively, but not control mice that received a mock MVTTS vaccine. However, MVTTHA-AH induced much lower levels of NT against its autologous strain. Our results suggest that it is feasible to use the H5 gene from A/Bar-headed Goose/Qinghai/1/2005 to construct an effective vaccine, when using MVTT as a vector, to prevent infections against homologous and genetically divergent human H5N1 influenza viruses.

  3. Analysis and protective measures of sharp instrument injury causes of sterilization and supply center

    Directory of Open Access Journals (Sweden)

    Hua YANG

    2014-11-01

    Full Text Available Objective: To analyze the causes of sharp injury in the sterilization and supply center, take protective measures, effectively avoid sharp instrument injury, and guarantee staff safety. Methods: Adopt a retrospective survey method, summarize sharp instrument injury data of sterilization and supply center in 2013, analyze the reasons of the occurrence of sharp instrument injury, and make protective countermeasures. Results: Sharp instrument injuries occurred mainly in the device classification, manual cleaning and device packaging process. Conclusion: Poor consciousness of occupational protection of the staff in the sterilization and supply center, nonstandard operation, and lack of training and supervision in place are the main reasons of occurrence of sharp instrument injury.

  4. Adjustable sterile lead apron for radiation protection during angiography

    Energy Technology Data Exchange (ETDEWEB)

    Grollman, J.H. Jr.; Sanchez, J.L.

    1979-08-01

    A simple sterile lead apron can be mounted directly on any vertical-beam image-intensifier housing and readjusted by the angiographer to shield himself from scatter during fluoroscopy and cineangiocardiography, even if the image intensifier is tilted in the longitudinal plane. Properly placed, the apron effectively reduces exposure due to scatter.

  5. Touch sensitivity with sterile standard surgical gloves and single-use protective gloves.

    Science.gov (United States)

    Tiefenthaler, W; Gimpl, S; Wechselberger, G; Benzer, A

    2006-10-01

    The purpose of this study was to evaluate touch sensitivity and static two-point discrimination of the dominant index and middle finger in 20 anaesthetists wearing no gloves, single-use protective gloves or sterile standard surgical gloves. Semmes-Weinstein filaments were used to measure cutaneous pressure thresholds, and a Two-Point-Discriminator to estimate static two-point discrimination. Wearing gloves significantly reduced touch sensitivity (p gloves. The results of our study suggest that the additional cost of sterile standard surgical gloves can not be justified in terms of touch sensitivity.

  6. A nonintegrative lentiviral vector-based vaccine provides long-term sterile protection against malaria.

    Directory of Open Access Journals (Sweden)

    Frédéric Coutant

    Full Text Available Trials testing the RTS,S candidate malaria vaccine and radiation-attenuated sporozoites (RAS have shown that protective immunity against malaria can be induced and that an effective vaccine is not out of reach. However, longer-term protection and higher protection rates are required to eradicate malaria from the endemic regions. It implies that there is still a need to explore new vaccine strategies. Lentiviral vectors are very potent at inducing strong immunological memory. However their integrative status challenges their safety profile. Eliminating the integration step obviates the risk of insertional oncogenesis. Providing they confer sterile immunity, nonintegrative lentiviral vectors (NILV hold promise as mass pediatric vaccine by meeting high safety standards. In this study, we have assessed the protective efficacy of NILV against malaria in a robust pre-clinical model. Mice were immunized with NILV encoding Plasmodium yoelii Circumsporozoite Protein (Py CSP and challenged with sporozoites one month later. In two independent protective efficacy studies, 50% (37.5-62.5 of the animals were fully protected (p = 0.0072 and p = 0.0008 respectively when compared to naive mice. The remaining mice with detectable parasitized red blood cells exhibited a prolonged patency and reduced parasitemia. Moreover, protection was long-lasting with 42.8% sterile protection six months after the last immunization (p = 0.0042. Post-challenge CD8+ T cells to CSP, in contrast to anti-CSP antibodies, were associated with protection (r = -0.6615 and p = 0.0004 between the frequency of IFN-g secreting specific T cells in spleen and parasitemia. However, while NILV and RAS immunizations elicited comparable immunity to CSP, only RAS conferred 100% of sterile protection. Given that a better protection can be anticipated from a multi-antigen vaccine and an optimized vector design, NILV appear as a promising malaria vaccine.

  7. Radiation sterilization

    International Nuclear Information System (INIS)

    Jacobs, G.P.

    1989-01-01

    In view of the application of ionizing radiation to sterilize pharmaceutical products, and the particular advantages of using this mode of sterilization for powders for injection, which cannot be sterilized by more conventional methods, it is important to recognise the possibility of modification of radiation response of bacteria when in close contact with various drug powders. For this study, bacterial spores, which lend themselves to dessication, and which can be dried onto an inert powder matrix, were chosen as the test system. The results of this work indicate that the additives tested have a modest protective effect on the spores. However, when considering a bacterial inactivation for sterilization purposes of between six and ten orders of magnitude, that is, a desired sterility assurance level of an expected maximum probability of a product item being non-sterile of 10 -6 , then the slight protective effect observed in this study approaches insignificance

  8. Atomic force microscopy imaging reveals the formation of ASIC/ENaC cross-clade ion channels

    International Nuclear Information System (INIS)

    Jeggle, Pia; Smith, Ewan St. J.; Stewart, Andrew P.; Haerteis, Silke; Korbmacher, Christoph; Edwardson, J. Michael

    2015-01-01

    ASIC and ENaC are co-expressed in various cell types, and there is evidence for a close association between them. Here, we used atomic force microscopy (AFM) to determine whether ASIC1a and ENaC subunits are able to form cross-clade hybrid ion channels. ASIC1a and ENaC could be co-isolated from detergent extracts of tsA 201 cells co-expressing the two subunits. Isolated proteins were incubated with antibodies against ENaC and Fab fragments against ASIC1a. AFM imaging revealed proteins that were decorated by both an antibody and a Fab fragment with an angle of ∼120° between them, indicating the formation of ASIC1a/ENaC heterotrimers. - Highlights: • There is evidence for a close association between ASIC and ENaC. • We used AFM to test whether ASIC1a and ENaC subunits form cross-clade ion channels. • Isolated proteins were incubated with subunit-specific antibodies and Fab fragments. • Some proteins were doubly decorated at ∼120° by an antibody and a Fab fragment. • Our results indicate the formation of ASIC1a/ENaC heterotrimers

  9. Atomic force microscopy imaging reveals the formation of ASIC/ENaC cross-clade ion channels

    Energy Technology Data Exchange (ETDEWEB)

    Jeggle, Pia; Smith, Ewan St. J.; Stewart, Andrew P. [Department of Pharmacology, University of Cambridge, Tennis Court Road, Cambridge CB2 1PD (United Kingdom); Haerteis, Silke; Korbmacher, Christoph [Institut für Zelluläre und Molekulare Physiologie, Friedrich-Alexander-Universität Erlangen-Nürnberg, Waldstrasse 6, 91054 Erlangen (Germany); Edwardson, J. Michael, E-mail: jme1000@cam.ac.uk [Department of Pharmacology, University of Cambridge, Tennis Court Road, Cambridge CB2 1PD (United Kingdom)

    2015-08-14

    ASIC and ENaC are co-expressed in various cell types, and there is evidence for a close association between them. Here, we used atomic force microscopy (AFM) to determine whether ASIC1a and ENaC subunits are able to form cross-clade hybrid ion channels. ASIC1a and ENaC could be co-isolated from detergent extracts of tsA 201 cells co-expressing the two subunits. Isolated proteins were incubated with antibodies against ENaC and Fab fragments against ASIC1a. AFM imaging revealed proteins that were decorated by both an antibody and a Fab fragment with an angle of ∼120° between them, indicating the formation of ASIC1a/ENaC heterotrimers. - Highlights: • There is evidence for a close association between ASIC and ENaC. • We used AFM to test whether ASIC1a and ENaC subunits form cross-clade ion channels. • Isolated proteins were incubated with subunit-specific antibodies and Fab fragments. • Some proteins were doubly decorated at ∼120° by an antibody and a Fab fragment. • Our results indicate the formation of ASIC1a/ENaC heterotrimers.

  10. Atomic force microscopy imaging reveals the formation of ASIC/ENaC cross-clade ion channels.

    Science.gov (United States)

    Jeggle, Pia; Smith, Ewan St J; Stewart, Andrew P; Haerteis, Silke; Korbmacher, Christoph; Edwardson, J Michael

    2015-08-14

    ASIC and ENaC are co-expressed in various cell types, and there is evidence for a close association between them. Here, we used atomic force microscopy (AFM) to determine whether ASIC1a and ENaC subunits are able to form cross-clade hybrid ion channels. ASIC1a and ENaC could be co-isolated from detergent extracts of tsA 201 cells co-expressing the two subunits. Isolated proteins were incubated with antibodies against ENaC and Fab fragments against ASIC1a. AFM imaging revealed proteins that were decorated by both an antibody and a Fab fragment with an angle of ∼120° between them, indicating the formation of ASIC1a/ENaC heterotrimers. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Protection of protein A-sepharose columns irradiated to sterilization doses

    International Nuclear Information System (INIS)

    Moore, J.S.; Power, D.M.; Tallentire, A.

    1996-01-01

    The effects of ionizing radiation on protein A-sepharose mini columns have been investigated. Radiolysis to a dose of 25 kGy is accompanied by a 55% loss of binding capacity to IgG. Various OH· radical scavengers have been used to render them radiation resistantat the high doses commonly used for the purpose of sterilization. Inclusion of mannitol at high concentrations (1 mol dm -3 ) partially protects the columns as does ascorbate (10 - 2 mol dm -3 ), the loss of binding being only ∼ 15% at 25 kGy. The mixture of mannitol (1 mol dm -3 ) and ascorbate (10 -2 mol dm -3 ) however protects to ∼5% decomposition. This value is not affected by the presence of oxygen at the beginning of irradiation. (Author)

  12. Phi ({Phi}) and psi ({Psi}) angles involved in malarial peptide bonds determine sterile protective immunity

    Energy Technology Data Exchange (ETDEWEB)

    Patarroyo, Manuel E., E-mail: mepatarr@gmail.com [Fundacion Instituto de Inmunologia de Colombia (FIDIC), Bogota (Colombia); Universidad Nacional de Colombia, Bogota (Colombia); Moreno-Vranich, Armando; Bermudez, Adriana [Fundacion Instituto de Inmunologia de Colombia (FIDIC), Bogota (Colombia)

    2012-12-07

    Highlights: Black-Right-Pointing-Pointer Phi ({Phi}) and psi ({Psi}) angles determine sterile protective immunity. Black-Right-Pointing-Pointer Modified peptide's tendency to assume a regular conformation related to a PPII{sub L}. Black-Right-Pointing-Pointer Structural modifications in mHABPs induce Ab and protective immunity. Black-Right-Pointing-Pointer mHABP backbone atom's interaction with HLA-DR{beta}1{sup Asterisk-Operator} is stabilised by H-bonds. -- Abstract: Modified HABP (mHABP) regions interacting with HLA-DR{beta}1{sup Asterisk-Operator} molecules have a more restricted conformation and/or sequence than other mHABPs which do not fit perfectly into their peptide binding regions (PBR) and do not induce an acceptable immune response due to the critical role of their {Phi} and {Psi} torsion angles. These angle's critical role was determined in such highly immunogenic, protection-inducing response against experimental malaria using the conformers (mHABPs) obtained by {sup 1}H-NMR and superimposed into HLA-DR{beta}1{sup Asterisk-Operator }-like Aotus monkey molecules; their phi ({Phi}) and psi ({Psi}) angles were measured and the H-bond formation between these molecules was evaluated. The aforementioned mHABP propensity to assume a regular conformation similar to a left-handed polyproline type II helix (PPII{sub L}) led to suggesting that favouring these conformations according to their amino acid sequence would lead to high antibody titre production and sterile protective immunity induction against malaria, thereby adding new principles or rules for vaccine development, malaria being one of them.

  13. Synchronous separation, seaming, sealing and sterilization (S4) using brazing for sample containerization and planetary protection

    Science.gov (United States)

    Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart; Bao, Xiaoqi; Lindsey, Cameron; Kutzer, Thomas; Salazar, Eduardo

    2018-03-01

    The return of samples back to Earth in future missions would require protection of our planet from the risk of bringing uncontrolled biological materials back with the samples. This protection would require "breaking the chain of contact (BTC)", where any returned material reaching Earth for further analysis would have to be sealed inside a container with extremely high confidence. Therefore, the acquired samples would need to be contained while destroying any potential biological materials that may contaminate the external surface of the container. A novel process that could be used to contain returning samples has been developed and demonstrated in a quarter scale size. The process consists of brazing using non-contact induction heating that synchronously separates, seams, seals and sterilizes (S4) the container. The use of brazing involves melting at temperatures higher than 500°C and this level of heating assures sterilization of the exposed areas since all carbon bonds (namely, organic materials) are broken at this temperature. The mechanism consists of a double wall container with inner and outer shells having Earth-clean interior surfaces. The process consists of two-steps, Step-1: the double wall container halves are fabricated and brazed (equivalent to production on Earth); and Step-2 is the S4 process and it is the equivalent to the execution on-orbit around Mars. In a potential future mission, the double wall container would be split into two halves and prepared on Earth. The potential on-orbit execution would consist of inserting the orbiting sample (OS) container into one of the halves and then mated to the other half and brazed. The latest results of this effort will be described and discussed in this manuscript.

  14. Phi (Φ) and psi (Ψ) angles involved in malarial peptide bonds determine sterile protective immunity.

    Science.gov (United States)

    Patarroyo, Manuel E; Moreno-Vranich, Armando; Bermúdez, Adriana

    2012-12-07

    Modified HABP (mHABP) regions interacting with HLA-DRβ1(∗) molecules have a more restricted conformation and/or sequence than other mHABPs which do not fit perfectly into their peptide binding regions (PBR) and do not induce an acceptable immune response due to the critical role of their Φ and Ψ torsion angles. These angle's critical role was determined in such highly immunogenic, protection-inducing response against experimental malaria using the conformers (mHABPs) obtained by (1)H-NMR and superimposed into HLA-DRβ1(∗)-like Aotus monkey molecules; their phi (Φ) and psi (Ψ) angles were measured and the H-bond formation between these molecules was evaluated. The aforementioned mHABP propensity to assume a regular conformation similar to a left-handed polyproline type II helix (PPII(L)) led to suggesting that favouring these conformations according to their amino acid sequence would lead to high antibody titre production and sterile protective immunity induction against malaria, thereby adding new principles or rules for vaccine development, malaria being one of them. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Postpartum Sterilization

    Science.gov (United States)

    f AQ FREQUENTLY ASKED QUESTIONS FAQ052 CONTRACEPTION Postpartum Sterilization • What is sterilization? • What is postpartum sterilization? • How is postpartum sterilization performed? • What kind of anesthesia is used for postpartum sterilization? • How ...

  16. Hysteroscopic Sterilization

    Science.gov (United States)

    ... sterilization? Sterilization is a permanent form of birth control. What is tubal sterilization? Sterilization procedures for women are ... is quicker than from other types of sterilization. What are the risks of ... on for birth control. • There is a risk of injury to the ...

  17. Sterile protection against Plasmodium knowlesi in rhesus monkeys from a malaria vaccine: comparison of heterologous prime boost strategies.

    Directory of Open Access Journals (Sweden)

    George Jiang

    Full Text Available Using newer vaccine platforms which have been effective against malaria in rodent models, we tested five immunization regimens against Plasmodium knowlesi in rhesus monkeys. All vaccines included the same four P. knowlesi antigens: the pre-erythrocytic antigens CSP, SSP2, and erythrocytic antigens AMA1, MSP1. We used four vaccine platforms for prime or boost vaccinations: plasmids (DNA, alphavirus replicons (VRP, attenuated adenovirus serotype 5 (Ad, or attenuated poxvirus (Pox. These four platforms combined to produce five different prime/boost vaccine regimens: Pox alone, VRP/Pox, VRP/Ad, Ad/Pox, and DNA/Pox. Five rhesus monkeys were immunized with each regimen, and five Control monkeys received a mock vaccination. The time to complete vaccinations was 420 days. All monkeys were challenged twice with 100 P. knowlesi sporozoites given IV. The first challenge was given 12 days after the last vaccination, and the monkeys receiving the DNA/Pox vaccine were the best protected, with 3/5 monkeys sterilely protected and 1/5 monkeys that self-cured its parasitemia. There was no protection in monkeys that received Pox malaria vaccine alone without previous priming. The second sporozoite challenge was given 4 months after the first. All 4 monkeys that were protected in the first challenge developed malaria in the second challenge. DNA, VRP and Ad5 vaccines all primed monkeys for strong immune responses after the Pox boost. We discuss the high level but short duration of protection in this experiment and the possible benefits of the long interval between prime and boost.

  18. A sterile sperm caste protects brother fertile sperm from female-mediated death in Drosophila pseudoobscura

    DEFF Research Database (Denmark)

    Holman, Luke; Snook, Rhonda R

    2008-01-01

    antispermicidal mechanisms have been definitively identified. One such adaptation may be the enigmatic infertile sperm morphs or "parasperm" produced by many species, which have been hypothesized to protect their fertile brother "eusperm" from spermicide [2, 3]. Here, we show that female Drosophila pseudoobscura...

  19. Evolution of Neutralization Response in HIV-1 Subtype C-Infected Individuals Exhibiting Broad Cross-Clade Neutralization of HIV-1 Strains

    Directory of Open Access Journals (Sweden)

    Narayanaiah Cheedarla

    2018-03-01

    Full Text Available Strain-specific neutralizing antibodies develop in all human immunodeficiency virus type 1 (HIV-1-infected individuals. However, only 10–30% of infected individuals produce broadly neutralizing antibodies (bNAbs. Identification and characterization of these bNAbs and understanding their evolution dynamics are critical for obtaining useful clues for the development of an effective HIV vaccine. Very recently, we published a study in which we identified 12 HIV-1 subtype C-infected individuals from India whose plasma showed potent and broad cross-clade neutralization (BCN ability (1. In the present study, we report our findings on the evolution of host bNAb response over a period of 4 years in a subset of these individuals. Three of the five individuals (NAB033, NAB059, and NAB065 demonstrated a significant increase (p < 0.05 in potency. Interestingly, two of the three samples also showed a significant increase in CD4 binding site-specific antibody response, maintained stable CD4+ T cell counts (>350 cells/mm3 and continued to remain ART-naïve for more than 10 years after initial diagnosis, implying a strong clinical correlation with the development and evolution of broadly neutralizing antibody response against HIV-1.

  20. Sterile neutrino

    International Nuclear Information System (INIS)

    Anon.

    2007-01-01

    Paper deals with the information on the occurrence of the fields of the sterile neutrinos (the righthanded ones) mixed with the normal neutrinos (the lefthanded ones). Both the Max Plank Radioastronomy Institute and the Los Angeles University assumes that the occurrence of the keV mass sterile neutrinos may explain the dark matter nature, the fast rotation of the observed pulsars and the reionization processes. The issues associated with the possibility to record the sterile neutrinos were analyzed in the course of the Sterile Neutrinos in Astrophysics and Cosmology Workshop (Crans Montana, March 2006 [ru

  1. Radiation sterilization of vitamins - studies on the radiolysis and radiation protection of vitamins in aqueous systems and the solid state

    International Nuclear Information System (INIS)

    Rao, K.N.; Moorthy, P.N.; Kishore, K.

    1978-01-01

    Radiation sterilization of pharmaceutical products may cause their radiation degradation and loss in their potency. Radiation degradation may even give rise to new products whose effects on the organisms could be different from the parent substances. Extent of radiolytic decomposition of vitamins thiamine, nicotinamide, riboflavine and pyridoxine was studied under controlled conditions so that either only the hydrated electrons (esub(aq)) or only hydrogen atom (H) and hydroxyl radical react with these molecules. Experiments were also conducted in which scavengers for these species were added to reduce radiolytic degradation of the vitamins. It was found that irradiation of vitamins in the frozen aqueous state and with addition of glucose reduces radiolytic degradation and their irradiation in dry solid state causes no detectable damage. The last finding indicates that the best method for radiation sterilization of vitamin preparations may be to irradiate the components in the dry solid state and then compound them together. (M.G.B.)

  2. DNA prime/Adenovirus boost malaria vaccine encoding P. falciparum CSP and AMA1 induces sterile protection associated with cell-mediated immunity.

    Directory of Open Access Journals (Sweden)

    Ilin Chuang

    Full Text Available BACKGROUND: Gene-based vaccination using prime/boost regimens protects animals and humans against malaria, inducing cell-mediated responses that in animal models target liver stage malaria parasites. We tested a DNA prime/adenovirus boost malaria vaccine in a Phase 1 clinical trial with controlled human malaria infection. METHODOLOGY/PRINCIPAL FINDINGS: The vaccine regimen was three monthly doses of two DNA plasmids (DNA followed four months later by a single boost with two non-replicating human serotype 5 adenovirus vectors (Ad. The constructs encoded genes expressing P. falciparum circumsporozoite protein (CSP and apical membrane antigen-1 (AMA1. The regimen was safe and well-tolerated, with mostly mild adverse events that occurred at the site of injection. Only one AE (diarrhea, possibly related to immunization, was severe (Grade 3, preventing daily activities. Four weeks after the Ad boost, 15 study subjects were challenged with P. falciparum sporozoites by mosquito bite, and four (27% were sterilely protected. Antibody responses by ELISA rose after Ad boost but were low (CSP geometric mean titer 210, range 44-817; AMA1 geometric mean micrograms/milliliter 11.9, range 1.5-102 and were not associated with protection. Ex vivo IFN-γ ELISpot responses after Ad boost were modest (CSP geometric mean spot forming cells/million peripheral blood mononuclear cells 86, range 13-408; AMA1 348, range 88-1270 and were highest in three protected subjects. ELISpot responses to AMA1 were significantly associated with protection (p = 0.019. Flow cytometry identified predominant IFN-γ mono-secreting CD8+ T cell responses in three protected subjects. No subjects with high pre-existing anti-Ad5 neutralizing antibodies were protected but the association was not statistically significant. SIGNIFICANCE: The DNA/Ad regimen provided the highest sterile immunity achieved against malaria following immunization with a gene-based subunit vaccine (27%. Protection

  3. Women plan condom use after sterilization.

    Science.gov (United States)

    1998-12-01

    Sexual sterilization is highly effective in preventing pregnancy, but it does not protect against sexually transmitted diseases (STDs). People who accept sterilization as their method of family planning therefore need to be encouraged to protect themselves against HIV/AIDS and STDs even after they have been sterilized. Since women return less often to family planning providers following their sterilization procedure, they need to be advised to protect themselves against HIV and STDs before the sterilization is performed. 42% of the 2782 women who underwent tubal sterilizations at the Baylor College of Medicine in Houston during 1991-96 indicated their intention in a cross-sectional study to use condoms after sterilization. 20% of all respondents, aged 18-51 years, had a known risk factor for HIV, and almost 25% reported regular condom use for contraception or disease protection during the 3 months before sterilization. Planned condom use increased from 32% in 1991 to 51% in 1996, irrespective of age, marital status, or ethnic background. Of the 646 women who used condoms before being sterilized, almost half indicated no plans to do so after the procedure. The following factors were associated with condom use: relatively younger age, black ethnicity, unmarried status, history of previous STD, no steady partner, having a higher number of previous sex partners, past use of condoms to prevent disease transmission, and lack of partner involvement in the decision to undergo sterilization.

  4. Sterilization Monitoring management of the integration of the operating room with CSSD

    Directory of Open Access Journals (Sweden)

    Shu-yan XIA

    2014-08-01

    Full Text Available Objective: Explore the Sterilization Monitoring management of the integration of the operating room with CSSD. Methods: Compare sterilization process monitoring with biological monitoring and chemical monitoring. Results: The management in Biological monitoring, chemical monitoring and sterilization process monitoring is crucial. Conclusion: Sterilization monitoring is to ensure the safe use of sterile goods so as to protect the safety of surgical patients.

  5. Sewage sterilization through gamma radiation

    International Nuclear Information System (INIS)

    Vieira, D.V.; Teixeira, W.M.S.; Silva, F.C.A. da

    2017-01-01

    Lack of sewage treatment and adequate sanitation conditions can contribute to the proliferation of numerous parasitic and infectious diseases in addition to water degradation. Approximately fifty types of infections can be transmitted from a sick to a healthy person through different pathways involving human excreta. Untreated sewage can contaminate water, food, hands, soil, etc. Epidemics of certain diseases such as typhoid, cholera, dysenteries, etc., and countless cases of worms are responsible for high mortality rates in third world countries. In the work the different techniques of sewage treatment by disinfestation and sterilization were analyzed, highlighting the use and the advantages of the gamma radiation as well as the aspects of the radiological protection involved. The technique of sewage sterilization using gamma radiation is a method of controlling bacteria and microorganisms. It is estimated that more than 200 large irradiators are in operation worldwide, of which 5 are in Brazil, for general sterilization use. These facilities use a large amount of radioactive material, in the order of millions of Becquerel, for sterilization with high doses of radiation, which can generate lethal doses in a few minutes. These industrial facilities use Cobalt-60, being classified by the International Atomic Energy Agency - IAEA as Category 1 of high risk, and must possess a high level of radiological protection to carry out the sterilization, standing out the defense in depth. Specific legislation on radiological protection should be drafted for safe work and avoid future radiation accidents

  6. Laying-up of sterile instruments in the operating theatre: equal or superior protection by using a horizontal unidirectional air flow system.

    Science.gov (United States)

    Traversari, A A L; Goedhart, C A; Dusseldorp, E; Bode, A; Keuning, F; Pelk, M S J; Vos, M C

    2013-10-01

    A system for the preparation of sterilized instruments with unidirectional horizontal air flow (UDHF) has several advantages over a unidirectional down flow system (UDDF). The advantages are based on the installation of the system being more flexible and easier to use, no cooling of the air flow being necessary and less air being needed for circulation, resulting in reduced energy use. The objective of this study was to determine whether a system with UDHF performs equal or superior to a system with UDDF in terms of prevention of contamination of the air (the presence of particles and micro-organisms) during the laying-up process. The degree of protection (DP) offered by two UDHF system variants and two UDDF system variants was determined for several static set-ups and a dynamic simulation of the process. In addition to determining the level of protection for several categories of particle size, colony-forming units (CFU) were also measured during process simulations. When maximum protection (no particles present) is considered, the UDHF systems performed significantly better than the UDDF systems for particles ≥2.5μm. When particles were present, there was no significant difference between systems for particles ≥0.3 and ≥0.5μm. However, the performance of the UDHF system was superior to that of the UDDF system (DP) for particles ≥1.0μm representing the bacteria-carrying particles. During the process measurements, no CFU were found with the UDDF system in 64% of the measurements, compared with 90% for the UDHF system (P = 0.012). The UDHF system offers equal or superior protection to the UDDF system against contamination of the clean area within which the laying up takes place. Despite our finding that the differences did not always reach statistical significance (due to low background concentrations), there is a clear trend, from the small-sized particles (≥1.0μm) up to the largest sizes considered, including bacteria-carrying particles, that

  7. Genetic basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Robinson, A.S.

    2014-01-01

    The use of the sterile insect technique for insect control relies on the introduction of sterility in the females of the wild population. This sterility is produced following the mating of these females with released males carrying, in their sperm, dominant lethal mutations that have been induced by ionizing radiation. As well as radiation-induced sterility, natural mechanisms can be recruited, especially the use of hybrid sterility. Radiation is usually one of the last procedures that insects undergo before leaving mass-rearing facilities for release in the field. It is essential that the dosimetry of the radiation source be checked to ensure that all the insects receive the required minimum dose. A dose should be chosen that maximizes the level of introduced sterility in the wild females in the field. Irradiation in nitrogen can provide protection against the detrimental somatic effects of radiation. Currently, the development of molecular methods to sterilize pest insects in the field, by the release of fertile insects carrying trans genes, is very much in vogue. It is concluded that using a physical process, such as radiation, will always have significant advantages over genetic and other methods of sterilization for the large-scale application of the sterile insect technique. (author)

  8. Gamma-sterilization

    International Nuclear Information System (INIS)

    Lindgren, E.

    1974-01-01

    The author makes a survey of his experience in sterilization and sterility control of medical products. At present three different methods are used, steamsterilization, gassterilizing and gammasterilizing. The investments and costs for gamma radiation is presented and a comparison of the costs for gamma- and gassterilization including sterility control is made. (M.S.)

  9. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  10. Eugenics and Involuntary Sterilization: 1907-2015.

    Science.gov (United States)

    Reilly, Philip R

    2015-01-01

    In England during the late nineteenth century, intellectuals, especially Francis Galton, called for a variety of eugenic policies aimed at ensuring the health of the human species. In the United States, members of the Progressive movement embraced eugenic ideas, especially immigration restriction and sterilization. Indiana enacted the first eugenic sterilization law in 1907, and the US Supreme Court upheld such laws in 1927. State programs targeted institutionalized, mentally disabled women. Beginning in the late 1930s, proponents rationalized involuntary sterilization as protecting vulnerable women from unwanted pregnancy. By World War II, programs in the United States had sterilized approximately 60,000 persons. After the horrific revelations concerning Nazi eugenics (German Hereditary Health Courts approved at least 400,000 sterilization operations in less than a decade), eugenic sterilization programs in the United States declined rapidly. Simplistic eugenic thinking has faded, but coerced sterilization remains widespread, especially in China and India. In many parts of the world, involuntary sterilization is still intermittently used against minority groups.

  11. Radiosterilization and gas sterilization

    International Nuclear Information System (INIS)

    Schultz, H.A.; Gruenewald, T.

    1987-01-01

    The book presents a survey of the principles of cold sterilization by radiation or gas, and also of the problems involved. The reader who has to do with sterilization of some kind or other, as e.g. sterilization of medicaments, medical supplies, medical device, drugs, grafts, or food, will find comprehensive information on the various available methods and their effects, as well as on monitoring procedures and techniques, together with proposals for efficient documentation and validation of partial sterilization processes. The introduction summarizes the potentials of sterilization by radiation, and the subsequent by radiation, and the subsequent chapters explain the specific applicabilities of radiosterilization along with the most important criteria for evaluating the sterilizing efficiency. The information on the legal situation and requirements takes into account the second amendment of the Medical Preparations Act. With 38 figs., 14 tabs [de

  12. Sterile Neutrinos in Cold Climates

    International Nuclear Information System (INIS)

    Jones, Benjamin J.P.

    2015-01-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin 2 2θ 24 ≤ 0.02 at m 2 ~ 0.3 eV 2 , and the LSND and MiniBooNE allowed regions are excluded at

  13. Inherited sterility in insects

    International Nuclear Information System (INIS)

    Carpenter, J.E.; Marec, F.; Bloem, S.

    2005-01-01

    The unique genetic phenomena responsible for inherited sterility (IS) in Lepidoptera and some other arthropods, as compared with full sterility, provide advantages for pest control. Lepidopteran females are usually more sensitive to radiation than males of the same species. This allows the radiation dose to be adjusted to suit programme requirements. When partially sterile males mate with wild females, the radiation-induced deleterious effects are inherited by the F 1 generation. As a result, egg hatch is reduced and the resulting offspring are both highly sterile and predominately male. Compared with the high radiation required to achieve full sterility in Lepidoptera, the lower dose of radiation used to induce F 1 sterility increases the quality and competitiveness of the released insects as measured by improved dispersal after release, increased mating ability, and superior sperm competition. F 1 sterile progeny produced in the field enhance the efficacy of released partially sterile males, and improve compatibility with other pest control strategies. In addition, F 1 sterile progeny can be used to increase the production of natural enemies, and to study the potential host and geographical ranges of exotic lepidopteran pests. (author)

  14. Reversibility of female sterilization.

    Science.gov (United States)

    Siegler, A M; Hulka, J; Peretz, A

    1985-04-01

    The discussion considers the current status of reversibility of sterilization in the US and describes clinical and experimental efforts for developing techniques designed for reversibility. It focuses on regret following sterilization, reversal potential of current sterilization techniques, patient selection, current reversal techniques, results of sterilization procedures, experimental approaches to reversal of current techniques of sterilization, and sterilization procedures devised for reversibility, in humans and in animals. Request is the 1st stage of reversal, but a request for sterilization reversal (SR) does not always mean regret for a decision made at the time. Frequently it is a wish to restore fertility because life circumstances have changed after a sterilization that was ppropriate at the time it was performed. Schwyhart and Kutner reviewed 22 studies published between 1949-69 in which they found that the percentage of patients regretting the procedure ranged from 1.3-15%. Requests for reversal remain low in most countries, but if sterilization becomes a more popular method of contraception, requests will also increase. The ideal operation considered as a reversaible method of sterilization should include an easy, reliable outpatient method of tubal occlusion with miniml risk or patient discomfort that subsequently could be reversed without the need for a major surgical intervention. Endoscopic methods have progressed toward the 1st objective. A recent search of the literature uncovered few series of SR of more than 50 cases. The 767 operations found were analyzed with regard to pregnancy outcome. The precent of live births varied from 74-78.8%, and the occurance of tubal pregnancies ranged from 1.7-6.5%. All of the confounding variables in patient selection and small numbers of reported procedures preclude any conclusion about the different techniques or the number of operations that give a surgeon a level of expertise. Few authors classify their

  15. Modular ionizing sterilizer (MIS)

    International Nuclear Information System (INIS)

    Freijo, Jose L.

    1999-01-01

    A transportable device designed to sterilize medical material and wastes by gamma irradiation is described. The sterilizer is formed by three modules: one of the modules contains the gamma source and can be removed to transport and transfer the source, the other modules are designed to introduce and draw out the materials to be irradiated

  16. Comprehensive Cross-Clade Characterization of Antibody-Mediated Recognition, Complement-Mediated Lysis, and Cell-Mediated Cytotoxicity of HIV-1 Envelope-Specific Antibodies toward Eradication of the HIV-1 Reservoir.

    Science.gov (United States)

    Mujib, Shariq; Liu, Jun; Rahman, A K M Nur-Ur; Schwartz, Jordan A; Bonner, Phil; Yue, Feng Yun; Ostrowski, Mario A

    2017-08-15

    Immunotherapy with passive administration of broadly neutralizing HIV-1 envelope-specific antibodies (bnAbs) in the setting of established infection in vivo has yielded mixed results. The contribution of different antibodies toward the direct elimination of infected cells is poorly understood. In this study, we determined the ability of 12 well-characterized anti-HIV-1 neutralizing antibodies to recognize and eliminate primary CD4 T cells infected with HIV-1 belonging to clades A, B, C, and D, via antibody-dependent complement-mediated lysis (ADCML) and antibody-dependent cell-mediated cytotoxicity (ADCC), in vitro We further tested unique combinations of these antibodies to determine the optimal antibody cocktails to be tested in future clinical trials. We report that antibody binding to infected CD4 T cells is highly variable and correlates with ADCML and ADCC processes. Particularly, antibodies targeting the envelope glycan shield (2G12) and V1/V2 site (PG9, PG16, and PGT145) are best at recognizing HIV-1-infected CD4 T cells. However, only PG9 and PG16 and their combinations with other bnAbs sufficiently induced the elimination of HIV-1-infected CD4 T cells by ADCML, ADCC, or both. Notably, CD4 binding site antibodies VRC01, 3BNC117, and NIH45-46 G54W did not exhibit recognition of infected cells and were unable to induce their killing. Future trials geared toward the development of a cure for HIV/AIDS should incorporate V1/V2 antibodies for maximal clearance of infected cells. With the use of only primary immune cells, we conducted a comprehensive cross-clade physiological analysis to aid the direction of antibodies as therapeutics toward the development of a cure for HIV/AIDS. IMPORTANCE Several antibodies capable of neutralizing the majority of circulating HIV-1 strains have been identified to date and have been shown to prevent infection in animal models. However, the use of combinations of such broadly neutralizing antibodies (bnAbs) for the treatment and

  17. Protection of macaques with diverse MHC genotypes against a heterologous SIV by vaccination with a deglycosylated live-attenuated SIV.

    Directory of Open Access Journals (Sweden)

    Chie Sugimoto

    Full Text Available HIV vaccine development has been hampered by issues such as undefined correlates of protection and extensive diversity of HIV. We addressed these issues using a previously established SIV-macaque model in which SIV mutants with deletions of multiple gp120 N-glycans function as potent live attenuated vaccines to induce near-sterile immunity against the parental pathogenic SIVmac239. In this study, we investigated the protective efficacy of these mutants against a highly pathogenic heterologous SIVsmE543-3 delivered intravenously to rhesus macaques with diverse MHC genotypes. All 11 vaccinated macaques contained the acute-phase infection with blood viral loads below the level of detection between 4 and 10 weeks postchallenge (pc, following a transient but marginal peak of viral replication at 2 weeks in only half of the challenged animals. In the chronic phase, seven vaccinees contained viral replication for over 80 weeks pc, while four did not. Neutralizing antibodies against challenge virus were not detected. Although overall levels of SIV specific T cell responses did not correlate with containment of acute and chronic viral replication, a critical role of cellular responses in the containment of viral replication was suggested. Emergence of viruses with altered fitness due to recombination between the vaccine and challenge viruses and increased gp120 glycosylation was linked to the failure to control SIV. These results demonstrate the induction of effective protective immune responses in a significant number of animals against heterologous virus by infection with deglycosylated attenuated SIV mutants in macaques with highly diverse MHC background. These findings suggest that broad HIV cross clade protection is possible, even in hosts with diverse genetic backgrounds. In summary, results of this study indicate that deglycosylated live-attenuated vaccines may provide a platform for the elucidation of correlates of protection needed for a

  18. [Sterilization and eugenics].

    Science.gov (United States)

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  19. [Legal statutes on sterilization].

    Science.gov (United States)

    Zupancic, K

    1980-01-01

    Sterilization in Yugoslavia is no population policy measure. Decision about the birth of children is free, a private problem of any individual, a basic right guaranteed by the Constitution. However, according to certain laws in Slovenia and Croatia, sterilization is allowed as a family planning method in persons over 35 year old. Only exceptionally can sterilization be applied in persons younger than 35 years: according to the Slovenian law, in cases when a person lacks the capacity of reasoning and also when there are medical indications, and according to the Croatian law, when there are medical and eugenic reasons (if the child is supposed to be born with negative congenital properties).

  20. Materials Surfaces and sterility

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R.

    2001-04-01

    A question of great interest in sterile and clean room technology is how can we devise a standard for the guarantee of sterility? Sterility is of widespread importance: it gives the life-time of our daily milk or yogurt, dominates the nature of food packing, and determines the feasibility of the miniaturization of biotechnology plants. All these phenomena are based on the principle of bioadhesion. Bioadhesion is also the basis of the biomimetic material technologies, like the attachment of selected protein layers that can be used for nanomasking. (orig.)

  1. Application of radiation sterilization to bone allografts

    International Nuclear Information System (INIS)

    Li Youchen; Li Baoxing; Sun Shiquan

    2003-01-01

    With prominent features of high penetration, no temperature increases, no harm residues and easy dose control, radiation sterilization technology is widely used in the sterilization of bone allografts. During the radiation sterilization of bone allografts, the irradiation dose should be optimized to ensure sterilization of grafts and preservation of biological properties of bone. The immunogenicity of allografts is decreased by irradiation. IAEA devoted great efforts to generalization of the radiation sterilization of tissue allografts in developing countries since 1986. Tissue Bank of China Institute for Radiation Protection (CIRP) was initially established in 1988 with the support of IAEA, afterwards restructured into Shanxi Provincial Tissue Bank (SPTB). The SPTB, as the first manufacturer of the irradiated bone allografts in the country, was granted production license by the State Food and Drug Administration of China. The SPTB sponsored IAEA/RCA Training Courses, National Symposium on Bone Grafting, and National Training Course on Bone Banking. Technique of radiation sterilization for bone grafts has become popularized in China after these activities. (authors)

  2. Transgenic Parasites Stably Expressing Full-Length Plasmodium falciparum Circumsporozoite Protein as a Model for Vaccine Down-Selection in Mice Using Sterile Protection as an Endpoint

    Science.gov (United States)

    Porter, Michael D.; Nicki, Jennifer; Pool, Christopher D.; DeBot, Margot; Illam, Ratish M.; Brando, Clara; Bozick, Brooke; De La Vega, Patricia; Angra, Divya; Spaccapelo, Roberta; Crisanti, Andrea; Murphy, Jittawadee R.; Bennett, Jason W.; Schwenk, Robert J.; Ockenhouse, Christian F.

    2013-01-01

    Circumsporozoite protein (CSP) of Plasmodium falciparum is a protective human malaria vaccine candidate. There is an urgent need for models that can rapidly down-select novel CSP-based vaccine candidates. In the present study, the mouse-mosquito transmission cycle of a transgenic Plasmodium berghei malaria parasite stably expressing a functional full-length P. falciparum CSP was optimized to consistently produce infective sporozoites for protection studies. A minimal sporozoite challenge dose was established, and protection was defined as the absence of blood-stage parasites 14 days after intravenous challenge. The specificity of protection was confirmed by vaccinating mice with multiple CSP constructs of differing lengths and compositions. Constructs that induced high NANP repeat-specific antibody titers in enzyme-linked immunosorbent assays were protective, and the degree of protection was dependent on the antigen dose. There was a positive correlation between antibody avidity and protection. The antibodies in the protected mice recognized the native CSP on the parasites and showed sporozoite invasion inhibitory activity. Passive transfer of anti-CSP antibodies into naive mice also induced protection. Thus, we have demonstrated the utility of a mouse efficacy model to down-select human CSP-based vaccine formulations. PMID:23536694

  3. Sterilization of space hardware.

    Science.gov (United States)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  4. Sterilization by gamma irradiation

    International Nuclear Information System (INIS)

    Reyes Frias, L.

    1992-01-01

    Since 1980 the National Institute of Nuclear Research counts with an Industrial Gamma Irradiator, for the sterilization of raw materials and finished products. Through several means has been promoted the use of this technology as alternative to conventional methods of sterilization as well as steam treatment and ethylene oxide. As a result of the made promotion this irradiator has come to its saturation limit being the sterilization irradiation one of the main services that National Institute of Nuclear Research offers to producer enterprises of disposable materials of medical use also of raw materials for the elaboration of cosmetic products and pharmaceuticals as well as dehydrated foods. It is presented the trend to the sterilization service by irradiation showed by the compilation data in a survey made by potential customers. (Author)

  5. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  6. Auditing radiation sterilization facilities

    Science.gov (United States)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  7. Trends in sterilization since the introduction of Essure hysteroscopic sterilization.

    Science.gov (United States)

    Shavell, Valerie I; Abdallah, Mazen E; Shade, George H; Diamond, Michael P; Berman, Jay M

    2009-01-01

    To investigate trends in sterilization in women at the Detroit Medical Center, Michigan (DMC), since the introduction of Essure hysteroscopic sterilization. Retrospective study (Canadian Task Force classification II-2). Outpatient surgery center and university teaching hospitals. Women who underwent interval sterilization procedures at the DMC (Hutzel Women's Hospital, Sinai-Grace Hospital, and the Berry Center) and postpartum sterilization procedures at Hutzel Women's Hospital between January 1, 2002, and December 31, 2007. Permanent sterilization procedures including minilaparotomy tubal ligation, laparoscopic sterilization, Essure hysteroscopic sterilization, and postpartum tubal ligation performed at the time of cesarean section or after vaginal delivery. In all, 5509 permanent sterilization procedures were performed in the 6 years between January 1, 2002, and December 31, 2007, at the DMC facilities analyzed: 2484 interval sterilization procedures at Hutzel Women's Hospital, Sinai-Grace Hospital, and the Berry Center, and 3025 postpartum tubal ligations at Hutzel Women's Hospital. From 2002 through 2007, the decrease in laparoscopic sterilizations from 97.9% to 48.5% of all interval sterilization procedures corresponded significantly with the increase in Essure hysteroscopic sterilizations from 0.0% to 51.3% (p Essure hysteroscopic sterilizations increased significantly from 0.0% to 51.3% of all procedures. Since the approval of Essure hysteroscopic sterilization in November 2002, this minimally invasive method of hysteroscopic sterilization has increased in popularity at the DMC.

  8. Radiation sterilization of medical products

    International Nuclear Information System (INIS)

    Khurshid, S.J.; Hussain, A.M.

    1989-01-01

    Radiation sterilization is the best method of sterilization, essentially for single use medical and surgical products. Pakistan has established a commercial gamma irradiation plant for this purpose. This article overviews the advantages and benefits of radiation sterilization to stimulate the interest of industrialists and the users in this technology. This technology can give a better medical care in the country and the growing demand can only be met by bulk sterilization. The radiation sterilized medical products can also compete well with the products sterilized by other methods in the international market, gamma sterilization is accepted internationally and if adopted it can boost our export of medical products. (author)

  9. STERILIZATION AND DISINFECTION IN A PRIVATE CLINIC

    African Journals Online (AJOL)

    Oral examination is done with a mirror and probe. The mirror is then washed under the tap water and disinfected in 'V3 sterilizing' fluid concentrate. The probe is placed in a tray with ... Protective glasses are worn additionally to the gloves and facemask, when cavity preparation. is being performed. The handpiece is wiped.

  10. Radiation sterilization of livestock feeds

    International Nuclear Information System (INIS)

    Kawashima, Koji

    1984-01-01

    The radiation sterilization of livestock feeds is not much used presently because the process is not known well, and the cost is relatively high. However, its effect of sterilization is absolute, the radiation-sterilized feeds are safe in both nutrition and toxicity, and do not affect the appetite of livestocks, and the radiation energy required is small. In the future, as in the sterilization of medical supplies, feed radiation sterilization plants should be established, to stabilize livestock industry and to contribute to the health control of experimental animals. The following matters are described: radiation, comparison between radiation sterilization and other sterilization methods, the practice of feed radiation sterilization, the adverse effects of radiation sterilization, economic aspect, and the situation of feed radiation sterilization in various countries. (Mori, K.)

  11. Sterile Neutrinos in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Benjamin J.P. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  12. Radiation sterilization of pharmaceuticals and biomedical products

    International Nuclear Information System (INIS)

    Blackburn, R.; Iddon, B.; Moore, J.S.; Phillips, G.O.; Power, D.M.; Woodward, T.W.

    1975-01-01

    Sterilization of pharmaceuticals by radiation is accompanied by chemical degradation which must be eliminated or minimised if the method is to be successfully applied. In order to devise ways in which the pharmaceutical can be protected it is necessary to know the yield and nature of the decomposition products, the mechanisms by which degradation occurs, and the rate constants for the reactions involved. We have obtained such data for a variety of pharmaceutical compounds, viz. vitamin B12, benzyl penicillin, sulphonamides, indoles, heparin, alginates and phenylmercurics, both in the solid state and in aqueous solution. The scope and limitations of radiation sterilization are discussed in the light of these results. (author)

  13. Male sterility in chestnuts

    International Nuclear Information System (INIS)

    Omura, Mitsuo; Akihama, Tomoya

    1982-01-01

    A tentative plan was proposed for chestnuts based on their pollination system, male sterility and restoration. The studies on the male sterility of 1,063 cultivars and clones suggested that there were three types of male sterility. The first type (S-1) was characterized by antherless florets. In the second type (S-2), the catkins fell before anthesis, and the third type (S-3) appeared to develop normally in gross floral morphology, but the pollen grains were abnormal in shape and did not have germinating power. In an interspecific hybrid clone CS which belonged to S-1, fertility was restored in an open pollinated progeny. The use of CS and CSO-3 with its restored fertility, permitted the planning of breeding the chestnut hybrid cultivars propagated by seeds. The inbred clones with either male sterility or restorer genes are first bred mainly by back crossing with parents with favorable pollen. The clones are selected individually for early bearing, wasp and disease resistance, and restoration. Then, the hybrid seedling lines between male sterile and restorer inbreds are evaluated for homogenity in nut characters and tree habits. Next, the hybrid seedling lines selected will be examined for crop yield, vigor and cross compatibility. The superior seedling lines are finally selected, and the parental inbreds are grafted to be propagated for seed production orchards. (Kaihara, S.)

  14. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Science.gov (United States)

    Galante, Raquel; Rediguieri, Carolina F; Kikuchi, Irene Satiko; Vasquez, Pablo A S; Colaço, Rogério; Serro, Ana Paula; Pinto, Terezinha J A

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  15. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Raquel Galante

    Full Text Available In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation, a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP hydrogel nanoparticles (CS-HNP, with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol. Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  16. Audits of radiation sterilization facilities

    International Nuclear Information System (INIS)

    Kelkar, Prabhakar M.

    2001-01-01

    Johnson and Johnson is the world leader in sterilization science and technology. A special group of scientists and technologists are engaged in the development of new methods of sterilization, worldwide monitoring of sterilization processes, equipment and approvals for all types of sterilization processes. Kilmer Conference in the alternate year for the benefit of all those involved in improvement in sterilization science is held. Cobalt-60 gamma radiation for sterilization of medical products on commercial scale is used. This kind of mammoth task can only be achieved through systematic method of planning, auditing, expert review and approval of facilities

  17. Sterility induction in tsetse

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, C F [London School of Hygiene and Tropical Medicine (UK); Langley, P A [Bristol Univ. (UK)

    1982-01-01

    The first laboratory and field experiments on genetic control were with tsetse flies, and they made use of the sterility in crosses and hybrids between closely related species of the Glossina morsitans complex. Backcrosses indicate that there are two separate sterility mechanisms involved: (a) genetic incompatibility between a mother and the products of alien genes in the embryo or larva in the uterus; (b) inability of hybrid males to inseminate due to incompatibility of their X-chromosomes with an alien Y or autosomes. The two largest sterile male release programmes have been in Tanzania and Upper Volta, and have used irradiation at the pupal or adult stage, respectively, for the production of sterility. Male tsetse are remarkably resistant to radiosterilization and, with the doses required to induce dominant lethals in more than 95% of sperms, premature senescence and lethargic behaviour of the males tends to result. With G. morsitans irradiated at the puparial stage these effects can be alleviated by the use of a nitrogen atmosphere during irradiation. If the puparia are then transferred to air at 11/sup 0/C for transport to the release site, immediate emergence occurs on re-warming after arrival. This advantageous procedure was used for the releases in Tanzania. In addition to dominant lethals, irradiation also produces chromosome translocations which cause inherited partial sterility. A homozygous translocation line was selected but this example did not have sufficient fitness to be used in a mass rearing programme. Chemosterilants can be applied by pupal dipping, adult contact with deposits or in aerosols. Studies are now in progress on their use in association with odour-baited traps or pheromone-baited decoys as a means of sterilizing the wild population and thus avoiding the costly and difficult process of mass rearing tsetse.

  18. Heat sterilization of wood

    Science.gov (United States)

    Xiping Wang

    2010-01-01

    Two important questions should be considered in heat sterilizing solid wood materials: First, what temperature–time regime is required to kill a particular pest? Second, how much time is required to heat the center of any wood configuration to the kill temperature? The entomology research on the first question has facilitated the development of international standards...

  19. MINOS Sterile Neutrino Search

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, David Jason [Univ. College London, Bloomsbury (United Kingdom)

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  20. Immunization with a Novel Human type 5 Adenovirus-Vectored Vaccine Expressing the Premembrane and Envelope Proteins of Zika Virus Provides Consistent and Sterilizing Protection in Multiple Immunocompetent and Immunocompromised Animal Models.

    Science.gov (United States)

    Guo, Qiang; Chan, Jasper Fuk-Woo; Poon, Vincent Kwok-Man; Wu, Shipo; Chan, Chris Chung-Sing; Hou, Lihua; Yip, Cyril Chik-Yan; Ren, Changpeng; Cai, Jian-Piao; Zhao, Mengsu; Zhang, Anna Jinxia; Song, Xiaohong; Chan, Kwok-Hung; Wang, Busen; Kok, Kin-Hang; Wen, Yanbo; Yuen, Kwok-Yung; Chen, Wei

    2018-03-29

    Zika virus (ZIKV) infection may be associated with severe complications and disseminated via both vector-borne and non-vector-borne routes. Adenovirus-vectored vaccines represent a favorable controlling measure for the ZIKV epidemic as they have been shown to be safe, immunogenic, and rapidly generable for other emerging viral infections. Evaluations of two previously reported adenovirus-vectored ZIKV vaccines were performed using non-lethal animal models and/or non-epidemic ZIKV strain. We constructed and evaluated two human adenovirus-5-vectored vaccines containing the ZIKV premembrane-envelope(Ad5-Sig-prM-Env) and envelope(Ad5-Env) proteins, respectively, in multiple non-lethal and lethal animal models using epidemic ZIKV strains. Both vaccines elicited robust humoral and cellular immune responses in immunocompetent BALB/c mice. Dexamethasone-immunosuppressed mice vaccinated with either vaccine demonstrated robust and durable antibody responses and significantly lower blood/tissue viral loads than controls(Panimal models, Ad5-Sig-prM-Env-vaccinated mice had significantly(P<0.05) higher titers of anti-ZIKV-specific neutralizing antibody titers and lower(undetectable) viral loads than Ad5-Env-vaccinated mice. The close correlation between the neutralizing antibody titer and viral load helped to explain the better protective effect of Ad5-Sig-prM-Env than Ad5-Env. Anamnestic response was absent in Ad5-Sig-prM-Env-vaccinated A129 mice. Ad5-Sig-prM-Env provided sterilizing protection against ZIKV infection in mice.

  1. STAT3, a Key Parameter of Cytokine-driven Tissue Protection During Sterile Inflammation – the Case of Experimental Acetaminophen (Paracetamol-induced Liver Damage

    Directory of Open Access Journals (Sweden)

    Heiko eMühl

    2016-05-01

    Full Text Available Acetaminophen (APAP, N-acetyl-p-aminophenol, or paracetamol overdosing is a prevalent cause of acute liver injury. While clinical disease is initiated by overt parenchymal hepatocyte necrosis in response to the analgetic, course of intoxication is substantially influenced by associated activation of innate immunity. This process is supposed to be set in motion by release of danger associated molecular patterns (DAMPs from dying hepatocytes and is accompanied by an inflammatory cytokine response. Murine models of APAP-induced liver injury emphasize the complex role that DAMPs and cytokines play in promoting either hepatic pathogenesis or resolution and recovery from intoxication. Whereas the function of key inflammatory cytokines is controversially discussed, a subclass of specific cytokines capable of efficiently activating the hepatocyte signal transducer and activator of transcription (STAT-3 pathway stands out as being consistently protective in murine models of APAP intoxication. Those include foremost interleukin (IL-6, IL-11, IL-13, and IL-22. Above all, activation of STAT3 under the influence of these cytokines has the capability to drive hepatocyte compensatory proliferation, a key principle of the regenerating liver. Herein, the role of these specific cytokines during experimental APAP-induced liver injury is highlighted and discussed in a broader perspective. In hard-to-treat or at-risk patients standard therapy may fail and APAP intoxication can proceed towards a fatal condition. Focused administration of recombinant STAT3-activating cytokines may evolve as novel therapeutic approach under those ill-fated conditions.

  2. Genetically conditioned male sterility

    International Nuclear Information System (INIS)

    Gottschalk, W.

    1976-01-01

    A survey is given of two different types of genetically controlled male sterility in higher plants. 'Functional' male sterility is due to the action of mutated genes causing a misdifferentiation of the growing points in different specific ways. Under the influence of the genes of this group either the stamens or the archespore tissues are not differentiated. In other mutants functionable male germ cells are produced but cannot be used for fertilizing the egg cells because the anthers remain closed or anthers and stigma become spatially separated from each other. Other genes of the group are responsible for the transformation of stamens into carpels, i.e. for a change of the hermaphrodite flower into a unisexually female one. A second type of male sterility is due to the action of ms genes influencing the course of micro-sporogenesis directly. They cause the breakdown of this process in a specific meiotic stage characteristic for each gene of the group. This breakdown is introduced by the degeneration of PMCs, microspores, or pollen grains preventing the production of male germ cells. The female sex organs remain uninfluenced. (author)

  3. Sterilization by oxygen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Adir Jose; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Silva Zambon, Luis da; Silva, Monica Valero da; Verdonck, Patrick Bernard

    2004-07-31

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  4. Validation of radiation sterilization process

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    The standards for quality management systems recognize that, for certain processes used in manufacturing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product. Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of sterilization process is monitored routinely and the equipment is maintained according to ISO 13 485. Different aspects of this norm are presented

  5. Sterilizing insects with ionizing radiation

    International Nuclear Information System (INIS)

    Bakri, A.; Mehta, K.; Lance, D.R.

    2005-01-01

    Exposure to ionizing radiation is currently the method of choice for rendering insects reproductively sterile for area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Gamma radiation from isotopic sources (cobalt-60 or caesium-137) is most often used, but high-energy electrons and X-rays are other practical options. Insect irradiation is safe and reliable when established safety and quality-assurance guidelines are followed. The key processing parameter is absorbed dose, which must be tightly controlled to ensure that treated insects are sufficiently sterile in their reproductive cells and yet able to compete for mates with wild insects. To that end, accurate dosimetry (measurement of absorbed dose) is critical. Irradiation data generated since the 1950s, covering over 300 arthropod species, indicate that the dose needed for sterilization of arthropods varies from less than 5 Gy for blaberid cockroaches to 300 Gy or more for some arctiid and pyralid moths. Factors such as oxygen level, and insect age and stage during irradiation, and many others, influence both the absorbed dose required for sterilization and the viability of irradiated insects. Consideration of these factors in the design of irradiation protocols can help to find a balance between the sterility and competitiveness of insects produced for programmes that release sterile insects. Many programmes apply 'precautionary' radiation doses to increase the security margin of sterilization, but this overdosing often lowers competitiveness to the point where the overall induced sterility in the wild population is reduced significantly. (author)

  6. A research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang

    2010-01-01

    Radiation sterilization is widely applied in food processing, Pharmaceutical Manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. The output value of radiation sterilization industry reached 0.1% of the GDP in some advanced countries (America and Japan...), under this standard, its output value in Sichuan province would be RMB1.2 hundred million, but now our capacity and scale of this industry is less than RMB40million.Research shows: there are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the 'bottleneck' restrictions of capacity and Inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity for radiation sterilization, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  7. Laparoscopic female sterilization.

    Science.gov (United States)

    Filshie, G M

    1989-09-01

    An overview of laparoscopic sterilization techniques from a historical and practical viewpoint includes instrumentation, operative techniques, mechanical occlusive devices, anesthesia, failure rates, morbidity and mortality. Laparoscope was first reported in 1893, but was developed simultaneously in France, Great Britain, Canada and the US in the 1960s. There are smaller laparoscopes for double-puncture procedures, and larger, single-puncture laparoscopes. To use a ring or clip, a much larger operating channel, up to 8 mm is needed. Insufflating gas may be CO2, which does not support combustion, but is more uncomfortable, NO2, which is also an anesthetic, and room air often used in developing countries. Unipolar electrocautery is now rarely used, in fact most third party payers do not allow it. Bipolar cautery, thermal coagulation and laser photocoagulation are safer methods. Falope rings, Hulka-Clemens, Filshie, Bleier, Weck and Tupla clips are described and illustrated. General anesthesia, usually a short acting agent with a muscle relaxant, causes 33% of the mortality of laparoscope, often due to cardiac arrest and arrhythmias, preventable with atropine. Local anesthesia is safer and cheaper and often used in developing countries. Failure rates of the various laparoscopic tubal sterilization methods are reviewed: most result from fistula formation. Mortality and morbidity can be caused by bowel damage, injury or infection, pre- existing pelvic infection, hemorrhage, gas embolism (avoidable by the saline drip test), and other rare events.

  8. A novel H6N1 virus-like particle vaccine induces long-lasting cross-clade antibody immunity against human and avian H6N1 viruses.

    Science.gov (United States)

    Yang, Ji-Rong; Chen, Chih-Yuan; Kuo, Chuan-Yi; Cheng, Chieh-Yu; Lee, Min-Shiuh; Cheng, Ming-Chu; Yang, Yu-Chih; Wu, Chia-Ying; Wu, Ho-Sheng; Liu, Ming-Tsan; Hsiao, Pei-Wen

    2016-02-01

    Avian influenza A(H6N1) virus is one of the most common viruses isolated from migrating birds and domestic poultry in many countries. The first and only known case of human infection by H6N1 virus in the world was reported in Taiwan in 2013. This led to concern that H6N1 virus may cause a threat to public health. In this study, we engineered a recombinant H6N1 virus-like particle (VLP) and investigated its vaccine effectiveness compared to the traditional egg-based whole inactivated virus (WIV) vaccine. The H6N1-VLPs exhibited similar morphology and functional characteristics to influenza viruses. Prime-boost intramuscular immunization in mice with unadjuvanted H6N1-VLPs were highly immunogenic and induced long-lasting antibody immunity. The functional activity of the VLP-elicited IgG antibodies was proved by in vitro seroprotective hemagglutination inhibition and microneutralization titers against the homologous human H6N1 virus, as well as in vivo viral challenge analyses which showed H6N1-VLP immunization significantly reduced viral load in the lung, and protected against human H6N1 virus infection. Of particular note, the H6N1-VLPs but not the H6N1-WIVs were able to confer cross-reactive humoral immunity; antibodies induced by H6N1-VLP vaccine robustly inhibited the hemagglutination activities and in vitro replication of distantly-related heterologous avian H6N1 viruses. Furthermore, the H6N1-VLPs were found to elicit significantly greater anti-HA2 antibody responses in immunized mice than H6N1-WIVs. Collectively, we demonstrated for the first time a novel H6N1-VLP vaccine that effectively provides broadly protective immunity against both human and avian H6N1 viruses. These results, which uncover the underlying mechanisms for induction of wide-range immunity against influenza viruses, may be useful for future influenza vaccine development. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Electrolytic silver ion cell sterilizes water supply

    Science.gov (United States)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  10. Thermalizing Sterile Neutrino Dark Matter.

    Science.gov (United States)

    Hansen, Rasmus S L; Vogl, Stefan

    2017-12-22

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  11. Thermalizing Sterile Neutrino Dark Matter

    Science.gov (United States)

    Hansen, Rasmus S. L.; Vogl, Stefan

    2017-12-01

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  12. Sterile Endophthalmitis after Intravitreal Injections

    Directory of Open Access Journals (Sweden)

    Joaquín Marticorena

    2012-01-01

    Full Text Available Sterile endophthalmitis appears as an infrequent complication of intravitreal injections and seems to develop mainly in the context of the off-label use of drugs that have not been conceived for intravitreous administration. The aetiology of sterile endophthalmitis, independently of the administered drug, remains uncertain and a multifactorial origin cannot be discarded. Sterile inflammation secondary both to intravitreal triamcinolone acetonide and to intravitreal bevacizumab share many characteristics such as the acute and painless vision loss present in the big majority of the cases. Dense vitreous opacity is a common factor, while anterior segment inflammation appears to be mild to moderate. In eyes with sterile endophthalmitis, visual acuity improves progressively as the intraocular inflammation reduces without any specific treatment. If by any chance the ophthalmologist is not convinced by the sterile origin of the inflammation, this complication must be treated as an acute endophthalmitis because of the devastating visual prognosis of this intraocular infection in the absence of therapy.

  13. Conditional sterility in plants

    Science.gov (United States)

    Meagher, Richard B.; McKinney, Elizabeth; Kim, Tehryung

    2010-02-23

    The present disclosure provides methods, recombinant DNA molecules, recombinant host cells containing the DNA molecules, and transgenic plant cells, plant tissue and plants which contain and express at least one antisense or interference RNA specific for a thiamine biosynthetic coding sequence or a thiamine binding protein or a thiamine-degrading protein, wherein the RNA or thiamine binding protein is expressed under the regulatory control of a transcription regulatory sequence which directs expression in male and/or female reproductive tissue. These transgenic plants are conditionally sterile; i.e., they are fertile only in the presence of exogenous thiamine. Such plants are especially appropriate for use in the seed industry or in the environment, for example, for use in revegetation of contaminated soils or phytoremediation, especially when those transgenic plants also contain and express one or more chimeric genes which confer resistance to contaminants.

  14. The Sterile Insect Technique

    International Nuclear Information System (INIS)

    Kiragu, J.

    2006-01-01

    Insect pests have caused an increasing problem in agriculture and human health through crop losses and disease transmission to man and livestock. Intervention to ensure food security and human health has relied on Integrated Pest Management (IPM) strategies to keep the pests population below economic injury levels. IPM integrate a variety of methods, but there has been over-reliance on chemical control following the discovery of insecticidal properties of DDT. It is now realized that, maintaining pest populations at controlled levels is unsustainable and eradication options is now being considered. Although the Sterile Insect Technique(SIT) could be used for insect suppression, it is gaining favour in the elimination (eradication) of the target pest population through Areawide-based IPM (Author)

  15. Sterile neutrino dark matter

    CERN Document Server

    Merle, Alexander

    2017-01-01

    This book is a new look at one of the hottest topics in contemporary science, Dark Matter. It is the pioneering text dedicated to sterile neutrinos as candidate particles for Dark Matter, challenging some of the standard assumptions which may be true for some Dark Matter candidates but not for all. So, this can be seen either as an introduction to a specialized topic or an out-of-the-box introduction to the field of Dark Matter in general. No matter if you are a theoretical particle physicist, an observational astronomer, or a ground based experimentalist, no matter if you are a grad student or an active researcher, you can benefit from this text, for a simple reason: a non-standard candidate for Dark Matter can teach you a lot about what we truly know about our standard picture of how the Universe works.

  16. Pain Associated With Hysteroscopic Sterilization

    Science.gov (United States)

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  17. Sterile neutrinos as dark matter

    International Nuclear Information System (INIS)

    Dodelson, S.; Widrow, L.M.

    1994-01-01

    The simplest model that can accommodate a viable nonbaryonic dark matter candidate is the standard electroweak theory with the addition of right-handed (sterile) neutrinos. We consider a single generation of neutrinos with a Dirac mass μ and a Majorana mass M for the right-handed component. If M much-gt μ (standard hot dark matter corresponds to M=0), then sterile neutrinos are produced via oscillations in the early Universe with energy density independent of M. However, M is crucial in determining the large scale structure of the Universe; for M∼100 eV, sterile neutrinos make an excellent warm dark matter candidate

  18. Male gametophytic sterility. 1 - Gametic sterilities and deletions in petunia

    Energy Technology Data Exchange (ETDEWEB)

    Cornu, A.; Maizonnier, D. (Station d' Amelioration des Plantes de l' I.N.R.A., Dijon (France))

    1982-01-01

    Terminal deletions induced by ionizing radiations in Petunia are not sexually transmitted. Cytogenetic study of plants with a heterozygous deletion and their progenies shows that this lack of transmission is accompanied by a gametic semi-sterility due to the fact that gametes carrying the deleted chromosome are not viable. The interest of such a male sterility with a gametophytic determinism for the study of sporophyte-gametophyte relationships is underlined.

  19. Food irradiation and sterilization

    Science.gov (United States)

    Josephson, Edward S.

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25-70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning is achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70-80°C (bacon to 53°C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40°C to -20°C). Radappertozed foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for "wholesomeness" (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effecys of radappertization on the "wholesomeness" characteristics of these foods.

  20. Food irradiation and sterilization

    International Nuclear Information System (INIS)

    Josephson, E.S.

    1981-01-01

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25 to 70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning in achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70 to 80 0 C (bacon to 53 0 C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurrence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40 0 C to -20 0 C). Radappertized foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for 'wholesomeness' (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effects of radappertization on the 'wholesomeness' characteristics of these foods. (author)

  1. Portable Decontamination and Sterilization System

    National Research Council Canada - National Science Library

    Bell, William; Smerjac, Suzanne; Smith, Bryan

    2004-01-01

    TDA Research, Inc., (TDA) is developing a portable system to generate chlorine dioxide, which can be used for biodecontamination of small items and to sterilize medical and dental instruments in austere environments...

  2. Documentation requirements for radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation for appr......Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation...... for approval of radiation sterilized products. The impact of these standards on the radiation sterilization is discussed, with special attention given to a few special issues, mainly traceability and uncertainty of measurement results....

  3. Steam sterilization does not require saturated steam

    NARCIS (Netherlands)

    van Doornmalen Gomez Hoyos, J. P.C.M.; Paunovic, A.; Kopinga, K.

    2017-01-01

    The most commonly applied method to sterilize re-usable medical devices in hospitals is steam sterilization. The essential conditions for steam sterilization are derived from sterilization in water. Microbiological experiments in aqueous solutions have been used to calculate various time–temperature

  4. Food packaging and radiation sterilization

    International Nuclear Information System (INIS)

    Kawamura, Yoko

    1998-01-01

    Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The γ ray and an electron beam are commonly used in radiation sterilization. The γ ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing relatively thin materials and surface sterilization due to the weak transmission. A typical sterilization dose is approximately 10-30 kGy. Direct effects impacting packaging materials, particularly plastics, include scission of polymer links, cross-linkage between polymers, and generating radiolysis products such as hydrogen, methane, aliphatic hydrocarbons, etc. Furthermore, under the existence of oxygen, the oxygen radicals generated by the radiation will oxidize and peroxidize polymer chains and will generate alcohol and carbonyl groups, which shear polymer links, and generate oxygen containing low molecular compounds. As a result, degradation of physical strength such as elongation and seal strength, generating foreign odor, and an increase in global migration values shown in an elution test are sometimes evident. The food packages have different shapes, materials, additives, number of microorganisms and purpose. Therefor the effects of radiation, the optimum dose and so on must be investigated on the individual package. (J.P.N.)

  5. Radiation sterilization of skin allograft

    Science.gov (United States)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  6. Radiation sterilization of skin allograft

    International Nuclear Information System (INIS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-01-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6 . The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2 . The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  7. Genomic networks of hybrid sterility.

    Directory of Open Access Journals (Sweden)

    Leslie M Turner

    2014-02-01

    Full Text Available Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities". The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL. Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  8. Genomic networks of hybrid sterility.

    Science.gov (United States)

    Turner, Leslie M; White, Michael A; Tautz, Diethard; Payseur, Bret A

    2014-02-01

    Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities"). The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus) provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL). Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is applicable in a broad

  9. Sterilization in Finland: from eugenics to contraception.

    Science.gov (United States)

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  10. Radiation: A means of sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, R N [International Atomic Energy Agency, Division of Life Sciences, Radiation Biology Section, Vienna (Austria)

    1975-12-15

    The sterilization of medical products by ionizing radiation is a well-established industrial process in a number of technologically advanced countries. It is indeed encouraging to note the rate of growth experienced during the past fifteen years. Starting with the first commercial plant in the early sixties in the USA there are to date more than sixty large facilities of this kind located in USA, Canada, Australia and the countries of Europe including USSR. The geographical distribution of these sterilization plants is rather unbalanced. In this respect Europe is far ahead of the other continents of the world, with about 65% of all sterilization plants, followed by North and South America with 17%, Asia with 8%, Australia and New Zealand with 9% and Africa with only 1%. During the last 10 years the IAEA has actively contributed to the development of radiation sterilization practices and technology in the Member States, with particular emphasis on the developing countries. Such promotional efforts have been made by (a) supporting co-ordinated research to accumulate relevant technical information, (b) organizing scientific meetings and training courses, (c) providing technical expertise in the form of fellowships and expert services, (d) providing technical assistance to conduct market surveys and economic feasibility assessment, (e) scientific publications, including technical manuals and proceedings reports, and (f) assistance in the formulation of an international 'Code of Practice' for standardization of the manufacturing practices for radiation sterilized medical products to meet the specified requirements of the various national Pharmacopoeias and of the international consumer market.

  11. Prospects of radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari

    1992-01-01

    Since radiation sterilization was first introduced in the United States in 1956 in the field of disposable medical devices, it has become an indispensable technique for sterilization because of the following reasons: (1) introduction into dialyzers, (2) introduction in medical device makers, (3) development of disposable medical devices associated with developing both high molecular chemistry and cool sterilization, (4) rationality of sterilization process, and (5) problems of sterilization with ethylene oxide gas. To promote the further development of radiation sterilization, the following items are considered necessary: (1) an increase in the number of facilities for radiation sterilization, (2) recommendation of the international standardization of sterilization method, (3) decrease in radiation doses associated with sterilization, (4) development of electron accelerators and bremsstrahlung equipments for radiation sources, and (5) simplification of sterilization process management. Factors precluding the development of radiation sterilization are: (1) development of other methods than radiation sterilization, (2) development of technique for sterile products, (3) high facility cost, (4) high irradiation cost, (5) benefits and limits of sterilization markets, and (6) influences of materials. (N.K.)

  12. The Sterile Insect Technique as a method of pest control

    International Nuclear Information System (INIS)

    Argiles Herrero, R.

    2011-01-01

    In the Valencia community is doing one of the most ambitious project in the field of plant protection at European level: the fight against fruit fly, one of the most damaging pests of citrus and fruit; by Insect Technique Sterile. This technique consists of laboratory breeding and release into the fields of huge quantities of insects of the pest species that have previously been sterilized. Sterile insect looking for wild individuals of the same species to mate with them and the result is a clutch of viable eggs, causing a decrease in pest populations. After three years of application of the technique on an area of 150,000 hectares, the pest populations have been reduced by 90%. Other benefits have been the reduced used of insecticides and improved the quality of exported fruit. (Author)

  13. Induction of Male sterile mutants in vegetable crops

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Nobuhiko [Hokkaido National Agricultural Experiment Station, Sapporo (Japan)

    1982-03-01

    The cultivars of vegetable crops in Japan are almost all F/sub 1/ hybrid lines. These hybrid cultivars are superior in yield, quality and uniformity by heterosis, and play an important role in the protection of breeder's rights. Utilization of male sterile mutants has such advantages as the reduction of cost for F/sub 1/ production by saving labor, production of better seeds, that is, pollination without emasculation and avoidance of contamination caused by self pollination. Male sterility must be used for some species in which seed production is difficult because of tiny flowers and meager seed production by artificial crossing such as carrot and onion, and those in which pollination by bag or emasculation is expensive such as tomato, and sweet pepper. However, for vegetable crop breeeding, the induction and use of genetic male sterility are more difficult than for other crops, considering the economy and efficiency of research because the type of cultivars needed changes rapidly.

  14. Induction of Male sterile mutants in vegetable crops

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Nobuhiko (Hokkaido National Agricultural Experiment Station, Sapporo (Japan))

    1982-03-01

    The cultivars of vegetable crops in Japan are almost all F/sub 1/ hybrid lines. These hybrid cultivars are superior in yield, quality and uniformity by heterosis, and play an important role in the protection of breeder's rights. Utilization of male sterile mutants has such advantages as the reduction of cost for F/sub 1/ production by saving labor, production of better seeds, that is, pollination without emasculation and avoidance of contamination caused by self pollination. Male sterility must be used for some species in which seed production is difficult because of tiny flowers and meager seed production by artificial crossing such as carrot and onion, and those in which pollination by bag or emasculation is expensive such as tomato, and sweet pepper. However, for vegetable crop breeeding, the induction and use of genetic male sterility are more difficult than for other crops, considering the economy and efficiency of research because the type of cultivars needed changes rapidly.

  15. Induction of Male sterile mutants in vegetable crops

    International Nuclear Information System (INIS)

    Nagata, Nobuhiko

    1982-01-01

    The cultivars of vegetable crops in Japan are almost all F 1 hybrid lines. These hybrid cultivars are superior in yield, quality and uniformity by heterosis, and play an important role in the protection of breeder's rights. Utilization of male sterile mutants has such advantages as the reduction of cost for F 1 production by saving labor, production of better seeds, that is, pollination without emasculation and avoidance of contamination caused by self pollination. Male sterility must be used for some species in which seed production is difficult because of tiny flowers and meager seed production by artificial crossing such as carrot and onion, and those in which pollination by bag or emasculation is expensive such as tomato, and sweet pepper. However, for vegetable crop breeeding, the induction and use of genic male sterility are more difficult than for other crops, considering the economy and efficiency of research because the type of cultivars needed changes rapidly. (Kaihara, S.)

  16. Investigation of radiation gamma-sterilization effect on sodium alginate hydrogels

    International Nuclear Information System (INIS)

    Valueva, M.I.; Oltarzhevskaya, N.D.; Maksimova, Yu.S.; Fenin, A.A.

    2012-01-01

    The effect of gamma-radiation in doses ensuring materials sterility (6-15 kGy) on alginate hydrogels is studied. For conservation of polymer solutions viscosity after sterilization it is necessary to introduce in polymer matrix different additives inhibiting the radiolysis process. Substances-antioxidants (aqueous extracts of sea-buckthorn and blueberry), polyvinylpyrrolidone, pectin, polyethylene oxides with molecular mass from 400 to 40000 have been studied as the additives. The additives selected have the positive effect on the result of alginate hydrogels sterilization. It is established, that the problem of human tissue radiation protection is closely connected with the problem of biopolymer hydrogels radiation protection [ru

  17. Research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang; Ouyang Qiongli

    2010-01-01

    Radiation sterilization is widely applied in food processing, pharmaceutical manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. There are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the restrictions of capacity and inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  18. Radiation sterilization of hydrocortisone acetate

    International Nuclear Information System (INIS)

    Charef, A.; Boussaha, A.

    1989-09-01

    The feasibility of using high energy ionizing radiation for the sterilization of hydrocortisone acetate was investigated. Hydrocortisone acetate in the form of powder was exposed to different dose levels of gamma radiation using a Cobalt-60 source. The irradiated samples were examined by various physico-chemical techniques in order to detect possible radiolysis products. It was of interest to know if one could insure sterility and retain biological properties of the drug by suitable choice of radiation dose. The results showed that a 10 KGy radiation dose causes no change in the physico-chemical properties of the drug and is sufficient to obtain contaminant-free product

  19. Plasma Sterilizer with Ultrasonic Cavitation

    International Nuclear Information System (INIS)

    Krasnyj, V.V.; Klosovsky, A.V.; Panasko, T.A.; Shvets, O.M.; Semenova, O.T.; Taran, V.S.; Tereshin, V.I.

    2006-01-01

    A sterilizer consists of ozone generator based on a barrier glow discharge with the flat electrodes covered with dielectric with a high-voltage pulsed power supply of up to 250 W (1). The sterilization camera is equipped with ultrasonic source with the power of 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. Ozone concentration in the aqueous solution was 6 mg/liter with ozone concentration at the output of ozone generator 30 mg/liter. The complete inactivation of spores took 15 min

  20. Male and female sterility in Zambia

    Directory of Open Access Journals (Sweden)

    Athena Pantazis

    2014-02-01

    Full Text Available Background: Population measures of sterility are traditionally constructed for women, despite fertility and sterility being conditions of the couple. Estimates of male sterility provide insight into population-level sterility, and complement estimates based solely on women. Objective: This study seeks to estimate male sterility for the Gwembe Tonga of Zambia using male birth histories collected by the Gwembe Tonga Research Project from 1957 to 1995, while providing context by estimating female sterility for the Gwembe Tonga, as well as female sterility in all of Zambia, from Zambian DHS data (1992, 1997, 2001-02, and 2007. Methods: Sterility is measured using the Larson-Menken subsequently infertile indicator. Estimates are produced using discrete time event history analysis. Results: The odds of sterility were higher for women than men, though women's odds of sterility were only 1.5 times that of men's in the middle reproductive years. The odds of sterility increased steadily with age for both men and women, and across all datasets. However, women's sterility increased much more sharply with age than men's did, and women's odds of sterility were higher than men's at all reproductive ages.

  1. Establishment of a sterilization dose

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    Factors that impact on product bioburden (population of diable microorganisms on or in product and/or sterile barrier system) are: Raw materials, components, product design and size, manufacturing process, manufacturing equipment, manufacturing environment and manufacturing location. Presented lecture describes all these factors in details

  2. Sterile neutrino constraints from cosmology

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, Georg G.

    2012-01-01

    The presence of light particles beyond the standard model's three neutrino species can profoundly impact the physics of decoupling and primordial nucleosynthesis. I review the observational signatures of extra light species, present constraints from recent data, and discuss the implications of po...... of possible sterile neutrinos with O(eV)-masses for cosmology....

  3. Sterile Neutrino Search with MINOS

    International Nuclear Information System (INIS)

    Devan, Alena V.

    2015-01-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm 2 . An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, Δm s 2 ~ 1 eV 2 . The results of the 2013 sterile neutrino search are presented here.

  4. Sterility test by radiometric technique

    International Nuclear Information System (INIS)

    Faruq, Muhammad

    1980-01-01

    Sterility test of pharmaceuticals can be carried out by the application of pharmacopoeia and radiometric technique. In Indonesia the application of pharmacopoeia technique is carried out through liquid germination for aerobacteria and for fungus and yeast. Radiometric technique is applied to autotrop and heterotrop bacteria. (SMN)

  5. Sterile Neutrino Search with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Devan, Alena V. [College of William and Mary, Williamsburg, VA (United States)

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  6. Sterilization can change properties of bioceramics

    International Nuclear Information System (INIS)

    Willmann, G.

    2003-01-01

    Bioceramics made of bioinert alumina or zirconia and bioactive hydroxyapatite are well established implant materials. Implants have to be cleaned and sterilized. When sterilized some bioceramics change their color. This may effect their properties. No decrease of mechanical strength is observed when sterilizing alumina and the novel ceramic biocomposite AMC (Alumina Matrix Composite) with steam or Co 60 Gamma irradiation. When sterilizing Y-TZP zirconia with steam a decrease of strength is observed. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [de

  7. Radiation sterilization: an industrial process

    International Nuclear Information System (INIS)

    Ley, F.J.

    1975-01-01

    A new dimension has been added to the use of radiation in the medical field with the introduction of radiation as a sterilizing agent. Its use in diagnosis through radioactive tracers or X-rays and in therapy administered with the most sophisticated of electrical machines or radioisotope units, is familiar in the hospital world, being well established therein. In contrast, the application of radiation sterilization is in industry where the installation of large radiation sources is already commonplace in many countries. The beginnings in the early 1950's centered on the Van de Graaff machine and linear accelerators and the pioneering efforts of Ethicon Inc. here in the United States must be recognized. However, although sterilization with electron beams is still current practice in a number of plants, the use of gamma rays from cobalt-60 is preferred. The first steps in this direction were taken by the U.K.A.E.A. which, in common with similar organizations elsewhere, was attempting to exploit the tremendous potential for cobalt-60 production arising through the rapid construction of nuclear reactors. The first full-scale commercial gamma plant was commissioned in the U.K. in 1960. It reached a loading of 500,000 curies before its demolition after twelve years of operation. The process gained rapid acceptance within industry and approval by health authorities because it provided a ''cold'' sterilization method combining the property of lethal effect with penetration. Its immediate impact occurred in the introduction of disposable products making it possible, for example, to use heat-labile plastics and new packaging materials and package designs. Certainly, the technique has proved complementary to sterilization methods based on heat and to the use of chemical agents, in particular ethylene oxide gas

  8. Reionization in sterile neutrino cosmologies

    Science.gov (United States)

    Bose, Sownak; Frenk, Carlos S.; Hou, Jun; Lacey, Cedric G.; Lovell, Mark R.

    2016-12-01

    We investigate the process of reionization in a model in which the dark matter is a warm elementary particle such as a sterile neutrino. We focus on models that are consistent with the dark matter decay interpretation of the recently detected line at 3.5 keV in the X-ray spectra of galaxies and clusters. In warm dark matter models, the primordial spectrum of density perturbations has a cut-off on the scale of dwarf galaxies. Structure formation therefore begins later than in the standard cold dark matter (CDM) model and very few objects form below the cut-off mass scale. To calculate the number of ionizing photons, we use the Durham semi-analytic model of galaxy formation, GALFORM. We find that even the most extreme 7 keV sterile neutrino we consider is able to reionize the Universe early enough to be compatible with the bounds on the epoch of reionization from Planck. This, perhaps surprising, result arises from the rapid build-up of high redshift galaxies in the sterile neutrino models which is also reflected in a faster evolution of their far-UV luminosity function between 10 > z > 7 than in CDM. The dominant sources of ionizing photons are systematically more massive in the sterile neutrino models than in CDM. As a consistency check on the models, we calculate the present-day luminosity function of satellites of Milky Way-like galaxies. When the satellites recently discovered in the Dark Energy Survey are taken into account, strong constraints are placed on viable sterile neutrino models.

  9. Lessons from the recent rise in use of female sterilization in Malawi.

    Science.gov (United States)

    Jacobstein, Roy

    2013-03-01

    Although female sterilization is the most widely used modern contraceptive method in the world, most family planning programs in Africa have had difficulty providing it. Malawi, however, despite daunting constraints, has made female sterilization widely and equitably accessible, thereby increasing method choice and helping its citizens better meet their reproductive intentions. Ten percent of currently married Malawian women of reproductive age rely on female sterilization for contraceptive protection, compared with less than 2 percent across Africa, and demand to limit births now exceeds demand to space births. Malawi's female sterilization prevalence surpasses that of some high-resource countries. Key service-delivery factors enabling this achievement include supportive policies, strong public-private partnerships, and mobile services delivered at no cost by dedicated providers. Challenges remain, but Malawi's achievement offers lessons for other countries with low availability of female sterilization and similar resource constraints. © 2013 The Population Council, Inc.

  10. Compodock, a new device for sterile docking

    NARCIS (Netherlands)

    van der Meer, P. F.; Biekart, F. T.; Pietersz, R. N.; Rebers, S. P.; Reesink, H. W.

    2000-01-01

    BACKGROUND: A new device for sterile docking, the Compodock (Fresenius NPBI Transfusion Technology), was developed for connecting PVC tubing for medical use while maintaining sterility. STUDY DESIGN AND METHODS: Sterility of the connections was assessed by welding tubing with a heavy exterior

  11. Informed consent needed for sterilization or research.

    Science.gov (United States)

    Barnett, B

    1998-01-01

    Informed choice involves enabling family planning clients to base their decisions about contraceptive use upon adequate information. It is a process in which clients give their permission to undergo a procedure, take a medication, or participate in a study after being fully informed. Informed consent protects an individual's freedom of choice, respects his or her autonomy, is important in both family planning programs and reproductive health research, and should always be available to clients seeking health services. Although written informed consent is not needed for most reproductive health services, it should be obtained from men and women who undergo sterilization, since that involves surgery and is considered permanent. In addition, people who volunteer to participate in contraceptive studies need to be fully informed of the risks and benefits of any new drugs or devices they receive. Volunteers should understand the potential effects of methods upon their physical health and other aspects of their lives. Ethical reviews need to be conducted before research begins.

  12. Model business plan for a sterile insect production facility

    International Nuclear Information System (INIS)

    2008-01-01

    For over 50 years the sterile insect technique (SIT) is a pest control strategy which has been used for eradication, and more recently for suppression, containment and prevention, of unwanted insect pest populations. Examples of successful applications of SIT, almost always applied in conjunction with other control methods in an area-wide integrated approach, are available from around the world. The development and application of SIT has relied overwhelmingly on public or donor initiative and funding throughout its history, although the private sector has always been involved as participants, cooperators or partners in funding. The demand for SIT, and therefore the market for sterile insects, has increased in recent years. This increase coincides with the introduction of new pests through the expansion of global trade and, at the same time, widespread pressure to find alternatives to pesticides. Recent improvements in the technology supporting SIT facilitate its application and suggest lower costs can be achieved. The conditions are therefore met for a greater commercialization of the technique to bring it in line with other pest control approaches that are fully integrated into a market approach. Several challenges arise, however, in pursuing sterile insect production as a commercial venture, ranging from intellectual property protection to pricing of the product. Routine insurance requirements, for instance, are complicated by the biological aspects of the business. This report is aimed at facilitating private sector involvement in the production of sterile insects for use in pest control. It provides guidelines and tools to support the development of specific business plans for a new SIT venture. By providing an international perspective on such issues as initial capital costs and recurring operational expenditures for a sterile insect facility, it may be used to evaluate the feasibility of proceeding with the construction or expansion of a sterile insect

  13. Radiosterilization or sterilization by steam. Procedures for sterilization of spices

    International Nuclear Information System (INIS)

    Warmbold, J.

    1994-01-01

    The article compares two different methods for the sterilization of spices, namely radiosterilization and sterilization with steam. The first method applies ionizing radiation which can alter the chemical composition of the products. Tests have shown, however, that radiation doses up to 10 kGy will not induce the formation of carcinogenic agents in the foodstuffs, or of toxic substances, and thus are a wholesome method of preservation. Any modifications of taste, color or smell, or loss of vitamins, can be avoided by proper dose control and standard irradiation conditions. Sterilization by steam is a method achieving substantial suppression of the formation of germs, aerobic spores, yeasts, mould, and gramnegative germs, while preserving in most cases the essential oils. It may result in sensoric alterations, i.e affect the color, smell or taste, but in general the spices thus treated preserved their characteristic properties. The method is a good alternative to radiosterilization. The article adds some concluding information on mandatory labelling of irradiated food imported from third countries

  14. Dosimetry for electron beam sterilization

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    According to ISO 11137-1 (sect 4.3.4) dosimetry used in the development, validation and routine control of the sterilization process shall have measurement traceability to national or international standards and shall have a known level of uncertainty. It can only be obtained through calibration of the dosimeters. In presented lecture different types of dosimeter systems for electron beams (calorimeters, radiochromic film dosimeters, alanine / EPR) and their calibration are described

  15. Mirror model for sterile neutrinos

    International Nuclear Information System (INIS)

    Berezinsky, Veniamin; Narayan, Mohan; Vissani, Francesco

    2003-01-01

    Sterile neutrinos are studied as subdominant contribution to solar neutrino physics. The mirror-matter neutrinos are considered as sterile neutrinos. We use the symmetric mirror model with gravitational communication between mirror and visible sectors. This communication term provides mixing between visible and mirror neutrinos with the basic scale μ=v EW 2 /M Pl =2.5x10 -6 eV, where v EW =174 GeV is the vacuum expectation value of the standard electroweak group and M Pl is the Planckian mass. It is demonstrated that each mass eigenstate of active neutrinos splits into two states separated by small Δm 2 . Unsuppressed oscillations between active and sterile neutrinos (ν a ↔ν s ) occur only in transitions between each of these close pairs ('windows'). These oscillations are characterized by very small Δm 2 and can suppress the flux and distort spectrum of pp-neutrinos in detectable way. The other observable effect is anomalous seasonal variation of neutrino flux, which appears in LMA solution. The considered subdominant neutrino oscillations ν a ↔ν s can reveal itself as big effects in observations of supernova neutrinos and high-energy (HE) neutrinos. In the case of HE neutrinos they can provide a very large diffuse flux of active neutrinos unconstrained by the e-m cascade upper limit

  16. The problem of sterility in men and women after wide area sub-diaphragmatic irradiation

    International Nuclear Information System (INIS)

    Dana, M.; Weisgerber, C.; Teillet, F.; Desprez-Curely, J.P.; Goguel, A.; Chotin, G.; Bernard, J.

    1976-01-01

    Sub-diaphragmatic irradiation in an upside down Y pattern for Hodgkin's disease results in sterility in the woman. Protection consists of irradiating the lumbar chain only when possible or by displacement of the ovary before irradiation, and laterally for preference. Although subsequent pregnancy is then possible, the genetic risk remains. In the male, Y irradiation results in prolonged virtually complete azoospermia. Associated chemotherapy also causes definitive sterility in the male. Collection for a sperm bank before treatment is advised [fr

  17. Protective

    Directory of Open Access Journals (Sweden)

    Wessam M. Abdel-Wahab

    2013-10-01

    Full Text Available Many active ingredients extracted from herbal and medicinal plants are extensively studied for their beneficial effects. Antioxidant activity and free radical scavenging properties of thymoquinone (TQ have been reported. The present study evaluated the possible protective effects of TQ against the toxicity and oxidative stress of sodium fluoride (NaF in the liver of rats. Rats were divided into four groups, the first group served as the control group and was administered distilled water whereas the NaF group received NaF orally at a dose of 10 mg/kg for 4 weeks, TQ group was administered TQ orally at a dose of 10 mg/kg for 5 weeks, and the NaF-TQ group was first given TQ for 1 week and was secondly administered 10 mg/kg/day NaF in association with 10 mg/kg TQ for 4 weeks. Rats intoxicated with NaF showed a significant increase in lipid peroxidation whereas the level of reduced glutathione (GSH and the activity of superoxide dismutase (SOD, catalase (CAT, glutathione S-transferase (GST and glutathione peroxidase (GPx were reduced in hepatic tissues. The proper functioning of the liver was also disrupted as indicated by alterations in the measured liver function indices and biochemical parameters. TQ supplementation counteracted the NaF-induced hepatotoxicity probably due to its strong antioxidant activity. In conclusion, the results obtained clearly indicated the role of oxidative stress in the induction of NaF toxicity and suggested hepatoprotective effects of TQ against the toxicity of fluoride compounds.

  18. Plasma Sterilization: New Epoch in Medical Textiles

    Science.gov (United States)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  19. Regret following female sterilization in Slovenia.

    Science.gov (United States)

    Becner, Anja; Turkanović, Anela Bečić; But, Igor

    2015-07-01

    To estimate the regret rate and risk factors for regret among women who have undergone sterilization. A retrospective study was conducted among all women who underwent a sterilization procedure at the University Medical Center Maribor, Maribor, Slovenia, in 2008-2012. Identified women were contacted and asked to complete an online questionnaire assessing regret and symptoms associated with depression. Among 714 identified women, 308 (43.1%) completed the questionnaire. Four (1.3%) participants reported regret, and 9 (2.9%) reported that they would not opt for sterilization again, all of whom had post-sterilization problems. Such problems were significantly associated with participants reporting that they would not opt for sterilization again (P=0.003). Additionally, women who would not choose sterilization again had significantly higher scores on the depressive scale used than did those who would undergo sterilization again (P=0.028). Few women report regret after tubal sterilization in Slovenia. However, an additional consultation on post-sterilization problems and depressive disorder before sterilization might minimize the risk of regret. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  20. The Effect of Two Different Sterilization Methods on The Surface Topography and Microbial Contamination of Different Types of Endodontic Files

    International Nuclear Information System (INIS)

    Yousri, H.R.M.

    2014-01-01

    Sterilization is an integral part of the dental field. Sterilization should be used for instruments, surgical gloves and other items that come in direct contact with the blood stream or normally sterile tissues. Because sterilization is a process, not a single event, all components must be carried out correctly for sterilization to occur. To be effective, sterilization requires time, contact, temperature and with steam sterilization, high pressure. The effectiveness of any method of sterilization is also dependent upon four other factors: The type of microorganism present, the number of microorganisms present, the amount and type of organic material that protects the microorganisms and the number of cracks and crevices on an instrument that might harbor microorganisms. The most commonly used and standard methods of sterilization is the steam under pressure method using the autoclaves. However, it's not free from drawbacks; where it is not suitable for the heat sensitive equipment's such as the plastics, rubber. Also repeated autoclaving can cause pitting and dulling of cutting edges of instruments which might affect their clinical performance. Another alternative method of sterilization is by gamma rays which have been introduced for the sterilization of heat sensitive equipment's. Therefore conducting a study to investigate the effect of repeated sterilization cycles by either steam under pressure or gamma radiation on the surface topography of root canal enlarging instruments was thought to be valuable. The null hypothesis tested is that there is no difference in the effect of repeated sterilization by either steam under pressure or gamma radiation on the surface topography of root canal enlarging instruments

  1. Birth planning and sterilization in China.

    Science.gov (United States)

    Short, S E; Linmao, M; Wentao, Y

    2000-11-01

    Sterilization is the most prevalent method of contraception in China. Approximately half of all women of reproductive age report that they or their husbands are sterilized. Using data from the China Health and Nutrition Survey we describe patterns of sterilization in eight Chinese provinces. With a discrete-time event history model we investigate the link between characteristics of local birth planning policy and the risk of sterilization. After controlling for parity, the risk of sterilization is highest in communities where birth planning policy is least strong as measured by exceptions to the one-child policy. These results suggest that couples with more flexibility in family building may have less control over contraceptive method use. Other factors affecting the risk of sterilization are a woman's age, parity, and whether or not she has a son. Our results emphasize the importance of taking into account multiple dimensions of reproductive behaviour when assessing one-child policy changes.

  2. Sterilization of heparinized cuprophan hemodialysis membranes

    OpenAIRE

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated. Sterilization did not result in a release of heparin or heparin fragments from heparinized Cuprophan. Sterilization of heparinized Cuprophan by means of EtO exposure and gamma irradiation induced a slight, i...

  3. EB surface sterilization of food material

    International Nuclear Information System (INIS)

    Kaneko, H.; Mizutani, A.; Kato, K.; Nishikimi, T.; Taniguchi, S.

    2001-01-01

    In this paper, we introduce a food irradiation with low energetic, lower than 300keV, electrons (so-called SOFT ELECTRON) as a rather new method of food sterilization. It is also a physical sterilization method, and free from the problems mentioned above. Low energetic electrons have small penetration power (50-200micron) through raw materials, and by selecting a proper energy of electrons we can sterilize only the surfaces or skins of target materials

  4. Cryoradiation sterilization - contemporary state and outlook

    International Nuclear Information System (INIS)

    Talrose, V.L.

    1995-01-01

    The new approach of radiation sterilization -cryoradiosterilization with programmed freezing - was developed for pharmaceutical solutions. Both scientific and technical problems are solved, the results are discussed. Programmed freezing of vials with the drug's solutions provides the high stability of soluted components with biological activity at sterilizing irradiation without significant change of sterilization doses. Physical, chemical, biological and pharmacological properties of a lot of drug solutions for injection satisfy official requirements after cryoradiation sterilization treatment. This method seems to be especially important for the protein systems which could be infected by dangerous viruses (VIH, hepatitis B): blood plasma, diagnostic sera, protein preparations manufactured from donor's blood, etc. (Author)

  5. Probabilistic model for sterilization of food

    International Nuclear Information System (INIS)

    Chepurko, V.V.; Malinovskij, O.V.

    1986-01-01

    The probabilistic model for radiation sterilization is proposed based on the followng suppositions: (1) initial contamination of a volume unit of the sterilized product m is described by the distribution of the probabilities q(m), (2) inactivation of the population from m of microorganisms is approximated by Bernoulli test scheme, and (3) contamination of unit of the sterilized product is independent. The possibility of approximation q(m) by Poisson distribution is demonstrated. The diagrams are presented permitting to evaluate the dose which provides the defined reliability of sterilization of food for chicken-gnotobionts

  6. Sterile neutrino dark matter with supersymmetry

    Science.gov (United States)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  7. Currently available devices for female sterilization.

    Science.gov (United States)

    Chapman, Lynne; Magos, Adam

    2005-09-01

    Sterilization is now the method of family planning most commonly used in the world. Over the last 150 years, research has evolved in the search for the ideal method of female sterilization. The procedure should ideally have high efficacy, be readily accessible and be personally and culturally acceptable. The method should be simple, quick, easily learned and be able to be performed in an outpatient setting without general anesthesia. The most common and effective method for sterilization has, thus far, been via the laparoscopic route. Hysteroscopic sterilization, however, potentially fulfills many of these ideal criteria, but until recently has remained more of a concept than a reality.

  8. MR imaging of ''sterilized'' lymphoma

    International Nuclear Information System (INIS)

    Zerhouni, E.A.; Fishman, E.K.; Jones, R.; Siegelman, S.S.; Soulen, R.L.

    1986-01-01

    Residual masses are commonly observed after effective therapy in patients with lymphoma. These masses may be sterile but their presence poses a management problem, inasmuch as there is no adequate means of distinguishing sterile from active masses. The potential role of MR imaging in this context was evaluated by studying a group of 15 patients with stable, residual, presumably inactive masses (as determined from CT) and comparing the MR imaging findings in patients with newly diagnosed, untreated or recently treated lymphoma. All patients underwent an MR imaging examination consisting of one short repetition time (TR), short echo time (TE) (T1-weighted) sequence and one long TR, long TE(T2-weighted) sequence. The signal intensity of the masses was compared with that of fat in each patient, for each sequence. In selected patients, sequential examinations showed a progressive evolution toward the inactive pattern over a period of several weeks. Active and inactive disease are well depicted on T1-weighted sequences but are not distinguishable from each other. On T2-weighted sequences active disease is poorly demonstrated because the lesions are isointense with fat, whereas inactive masses remain clearly identifiable because they are of much lower signal intensity than fat

  9. Gamma sterilization of disposable medical products (DMP's)

    International Nuclear Information System (INIS)

    Brinston, R.M.

    1990-01-01

    Ten million cubic meters (361 million cubic feet) of disposable medical products (DMP) and related health care items are estimated to be sterilized in the world. In this paper, current conditions and perspectives of gamma sterilization is discussed in comparison with ethylene oxide gas and electron beams. Of the total sterilization estimates for DMP, 2.8 million cubic meters (99 million cubic feet) are sterilized with gamma radiation, with a market share of 27%. Gamma radiation is becoming increased from both general market growth and the introduction of new products, as well as the conversion of product from ethylene oxide gas to cobalt-60. Regulatory pressures, legal considerations, and increasing publicity surrounding ethylene oxide usage are encouraging manufactures to switch to gamma radiation. Gamma's performance features include: no temperature change during the sterilization, high penetration, even through hermetically sealed packages, no residues, and no post-sterilization treatment or quarantine period. Gamma sterilization is economically beneficial in large volumes of product. Cost saving to the end user of gamma sterilization has meant lower minimum dose levels than 25 KGy. Despite of an increasingly accepted gamma radiation, there are still four factors to be considered, including cobalt-60 availability, price, transportation, and disposal. The price of cobalt-60 is based on neutron cost. In the future, cobalt-60 price is expected to be flat and enables gamma processing to become even more competitive with other sterilization methods. Gamma radiation using cobalt-60 has been proven as a safe, effective, and cost-competitive sterilization method for treating DMP and related health care items. It's wide use and many processing advantages will continue to make it a preferred sterilization method. (N.K.)

  10. Cosmology seeking friendship with sterile neutrinos

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, G.G.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile ...

  11. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    PRINCIPLES OF HEAT STERILIZATION. IN DENTAL PRACTICE. W.H. van Palenstein Helderman. Department of Community and Preventive Dentistry,. Faculty of Dentistry, Muhimbili University College of Health Sciences,. Dar es Salaam, Tanzania. Introduction. Sterilization is defined as the destruction of all forms of life ...

  12. Current Sterilization Protocols-An Orthodontic Perspective

    Directory of Open Access Journals (Sweden)

    Abraham Vinod Korath

    2010-01-01

    Part I of this article focuses on the working principles of various methods of sterilization with an appraisalof their effects on orthodontic instruments. Additionally,contributory factors of instrument damage is enumerated to emphasis the importance of adhering to precise protocols and manufacturer recommendations as well as in alleviating some misconceptions about sterilization induced instrument damage.

  13. Light Sterile Neutrinos: A White Paper

    DEFF Research Database (Denmark)

    Abazajian, K. N.; Acero, M. A.; Agarwalla, S. K.

    2012-01-01

    This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.......This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data....

  14. Male sterile mutant in Vigna radiata

    International Nuclear Information System (INIS)

    Pande, Kalpana; Raghuvanshi, S.S.

    1987-01-01

    Single and combined treatment of γ-rays and 0.25 per cent EMS were tried on Vigna radiata variety K851. A male sterile mutant was isolated in M 2 generation. Experiments indicated male sterility to be recessive and monogenic in nature. 6 figures. (author)

  15. Sodium hypochlorite sterilization of culture medium in ...

    African Journals Online (AJOL)

    With the purpose of finding an alternative to thermal sterilization, this research aimed at assessing the efficiency and ideal concentration of sodium hypochlorite for sterilization of culture media and glassware used during rooting of micropropagated Gerbera hybrida cv. Essandre. Two experiments were carried out. In the first ...

  16. International Standards for Radiation Sterilization of Medical Devices

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    For a terminally sterilized medical device to be designated '' STERILE '', probability of finding the viable micro-organisms in the device shall be equal to or less than 1 x 10 -6 (EN 556-1:2001: Sterilization of medical devices - Requirements for medical devices to be designated '' STERILE '' - Part 1: Requirements for terminally sterilized medical devices). Author presents the main legal aspects of the international standards for radiation sterilization of medical devices

  17. Infection Risk in Sterile Operative Procedures.

    Science.gov (United States)

    Tacconelli, Evelina; Müller, Niklas F; Lemmen, Sebastian; Mutters, Nico T; Hagel, Stefan; Meyer, Elisabeth

    2016-04-22

    The main objective of hospital hygiene and infection prevention is to protect patients from preventable nosocomial infections. It was recently stated that the proper goal should be for zero infection rates in sterile surgical procedures. In this article, we attempt to determine whether this demand is supported by the available literature. We systematically searched the Medline and EMBASE databases for studies published in the last 10 years on the efficacy of infection control measures and carried out a meta-analysis according to the PRISMA tool. We used the following search terms: "aseptic surgery," "intervention," "surgical site infection," "nosocomial infection," "intervention," and "prevention." 2277 articles were retrieved, of which 204 were acquired in full text and analyzed. The quantitative analysis included 7 prospective cohort studies on the reduction of nosocomial infection rates after aseptic surgery. The measures used included training sessions, antibiotic prophylaxis, and operative-site disinfection and cleaning techniques. These interventions succeeded in reducing postoperative wound infections (relative risk (RR] 0.99 [0.98; 1.00]). Subgroup analyses on antibiotic prophylaxis (RR 0.99 [0.98; 1.01]) and noncontrolled trials (RR 0.97 [0.92; 1.02]) revealed small, insignificant effects. A multimodal approach with the participation of specialists from various disciplines can further reduce the rate of postoperative infection. A reduction to zero is not realistic and is not supported by available evidence.

  18. Development of sterilization and storage processes of Xeno-skins by gamma irradiation for the Industrialization as dressing materials

    International Nuclear Information System (INIS)

    Choi, Jong Il; Lee, Ju Woon; Kim, Jae Hun; Song, Beom Seok; Kim, Jae Kyung; Park, Jong Hum; Sung, Nak Yun; Jo, Eu Ri; Kim, Jeong Soo

    2011-08-01

    Allografts have been increased in concerns as treatment methods to be use in replacement and reconstruction procedures of tissue. The major concern about tissue and bone transplantation is the risk of transferring bacteria, viruses from recipient to the donors, especially from different species. To avoid these risks, tissue and bone banks use many different sterilization methods such as a deep-frozenness, freeze-drying ethylene oxide-sterilization and gamma-irradiation. Among these methods, gamma-irradiation has been widely used to sterilize the tissue for allograft and xenograft safety. Gamma irradiation could be an effective method for sterilization of soft tissue for the development of xenografts. Also, this study suggests the potential of development as tissue graft with the improved mechanical property of the structural stability and protection of tissue materials by antioxidant on porcine skin irradiated for sterilization and storage process

  19. Conflict over reproduction in an ant-plant symbiosis: why Allomerus octoarticulatus ants sterilize Cordia nodosa trees.

    Science.gov (United States)

    Frederickson, Megan E

    2009-05-01

    The evolutionary stability of mutualism is thought to depend on how well the fitness interests of partners are aligned. Because most ant-myrmecophyte mutualisms are persistent and horizontally transmitted, partners share an interest in growth but not in reproduction. Resources invested in reproduction are unavailable for growth, giving rise to a conflict of interest between partners. I investigated whether this explains why Allomerus octoarticulatus ants sterilize Cordia nodosa trees. Allomerus octoarticulatus nests in the hollow stem domatia of C. nodosa. Workers protect C. nodosa leaves against herbivores but destroy inflorescences. Using C. nodosa trees with Azteca ants, which do not sterilize their hosts, I cut inflorescences off trees to simulate sterilization by A. octoarticulatus. Sterilized C. nodosa grew faster than control trees, providing evidence for a trade-off between growth and reproduction. Allomerus octoarticulatus manipulates this trade-off to its advantage; sterilized trees produce more domatia and can house larger, more fecund colonies.

  20. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    Science.gov (United States)

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs.

  1. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

    Science.gov (United States)

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter

    2015-01-01

    Objective To compare the safety and efficacy of hysteroscopic sterilization with the “Essure” device with laparoscopic sterilization in a large, all-inclusive, state cohort. Design Population based cohort study. Settings Outpatient interventional setting in New York State. Participants Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Main outcomes measures Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. Results We identified 8048 patients undergoing hysteroscopic sterilization and 44 278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Conclusions Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures

  2. Seeking sterile neutrinos in Finslerian cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Deng [Nankai University, Theoretical Physics Division, Chern Institute of Mathematics, Tianjin (China); Meng, Xin-He [Nankai University, Department of Physics, Tianjin (China)

    2017-11-15

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H{sub 0} tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N{sub eff} = 3.237{sup +0.092}{sub -0.185}, which is consistent with ΔN{sub eff} > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N{sub eff} = 3.143{sup +0.064}{sub -0.066}, which favors ΔN{sub eff} > 0 at the 1.47σ CL, and m{sub ν,sterile}{sup eff} < 0.121 eV at the 2σ CL which is much tighter than the Planck results. This very tight restriction appears to indicate the massive sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration. (orig.)

  3. Forced sterilization of women as discrimination.

    Science.gov (United States)

    Patel, Priti

    2017-01-01

    There has been a long history of subjecting marginalized women to forced and coerced sterilization. In recent years, the practice has been documented in countries in North and South America, Europe, Asia, and Africa. It has targeted women who are ethnic and racial minorities, women with disabilities, women living with HIV, and poor women. A handful of courts have issued decisions on the recent forced sterilization of marginalized women finding that such actions violate the women's rights. However, they have all failed to address the women's claims of discrimination. The failure to acknowledge that forced sterilization is at its core a violation of the prohibition of discrimination undermines efforts to eradicate the practice. It further fails to recognize that coerced and forced sterilization fundamentally seeks to deny women deemed as "unworthy" the ability to procreate. Four key principles outlined in the human rights in patient care framework highlight the importance of a finding that the prohibition of discrimination was violated in cases of forced sterilization: the need to highlight the vulnerability of marginalized populations to discrimination in health care settings; the importance of the rights of medical providers; the role of the state in addressing systemic human rights violations in health care settings; and the application of human rights to patient care. Based on these principles, it is clear that finding a violation of the prohibition of discrimination in forced sterilization cases is critical in addressing the systemic nature of the practice, acknowledging the marginalization of specific groups and effectively ending forced sterilization through addressing the underlying purpose of the practice. If litigators, non-governmental organizations and judicial officers are mindful of these principles when dealing with cases of forced sterilization, it is likely that they will be better able to eradicate forced sterilization.

  4. Genetic basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Robinson, A.S.

    2005-01-01

    The use of the sterile insect technique (SIT) for insect control relies on the introduction of sterility in the females of the wild population. This sterility is produced following the mating of these females with released males carrying, in their sperm, dominant lethal mutations that have been induced by ionizing radiation. The reasons why the SIT can only be effective when the induced sterility in the released males is in the form of dominant lethal mutations, and not some form of sperm inactivation, are discussed, together with the relationship of dominant lethal mutations to dose, sex, developmental stage and the particular species. The combination of genetic sterility with that induced by radiation is also discussed in relation to the use of genetic sexing strains of the Mediterranean fruit fly Ceratitis capitata (Wiedemann) in area-wide integrated pest management (AW-IPM) programmes that integrate the SIT. A case is made to lower the radiation dose used in such programmes so as to produce a more competitive sterile insect. Increased competitiveness can also be achieved by using different radiation environments. As well as radiation-induced sterility, natural mechanisms can be recruited, especially the use of hybrid sterility exemplified by a successful field trial with tsetse flies Glossina spp. in the 1940s. Genetic transformation will make some impact on the SIT, especially regarding the introduction of markers for released flies, and the construction of genetic sexing strains. It is concluded that using a physical process, such as radiation, will always have significant advantages over genetic and other methods of sterilization for the large-scale application of the SIT. (author)

  5. Inheritance of sterility in Dysdercus koenigii F. (Hemiptera: Pyrrhocoridae)

    International Nuclear Information System (INIS)

    Harwalkar, M.R.; Rahalkar, G.W.

    1979-01-01

    It has been suggested that for the control of Lepidopterous populations, release of fully competitive partially sterile males would be more advantageous than the release of completely sterile males. This suggestion is based on the fact, elucidated in many studies, that partially sterilized males mated to normal females produce totally sterile or partially sterile progeny. In Hemiptera too, F 1 progeny of partially sterile males has been shown to inherit sterility. Individual impact of sterility inherited by either sex of the F 1 progeny on population growth has been studied in an hemipteran insect Dysdercus koenigii. A dose of 7 krad induces near-complete sterility in males. When males irradiated with substerilizing doses of 1,2 and 3 krad were crossed with normal females, F 1 progeny of both sexes was partially sterile : the female being more sterile than the males. When the F 1 progeny was intercrossed, there was enhanced reduction in progeny production. (auth.)

  6. Radiation sterilization facility for melon fly

    International Nuclear Information System (INIS)

    Danno, A.

    1985-01-01

    The melon fly (Dacus cucurbitae Coquillett) has been observed in Amami Island since l975. Kagoshima Prefecture has had a melon fly eradication project underway since 1979. A mass-fearing facility and a radiation sterilization facility were constructed in Naze in March of l98l. In the early stages of the project, sterile insects were produced at the rate of 4 x l0/sup 6/ pupae/week. In the later stages, the activity of the project was enlarged by tenfold. The conditions for design of the radiation sterilization facility, which has been developed with a central control system for automated irradiation, are examined from an engineering standpoint

  7. Cosmology seeking friendship with sterile neutrinos

    International Nuclear Information System (INIS)

    Hamann, J.; Hannestad, S.; Raffelt, G.G.; Tamborra, I.; Wong, Y.Y.Y.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile neutrino states from the most recent cosmological data. Our results are compatible with the existence of one or perhaps two sterile neutrinos, as suggested by LSND and MiniBooNE, if ms is in the sub-eV range.

  8. Observations on female sterilization in Chile.

    Science.gov (United States)

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical

  9. Spore-Forming Bacteria that Resist Sterilization

    Science.gov (United States)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  10. The development of new radiation protocols for insect sterilization using long wavelength x-rays

    Science.gov (United States)

    Urquidi, Jacob; Brar, Ramaninder K.; Rodriguez, Stacy; Hansen, Immo

    2015-07-01

    Control of insect species for the protection of crops, livestock, and prevention of disease such as dengue fever and malaria is a high priority in today's global economy. Traditional methods such as pesticides have fallen out of favor because its effects are indiscriminate as well as adverse and unpredictable impacts on the environment. Modern novel techniques such as genetic modification have had trouble gaining traction due to ethics concerns and the potential for unforeseen side effects. One approach that has gained traction and has proven its efficacy is the use of ionizing radiation to affect sterility in insect species in order to scale back their population. Known as Sterile Insect Technique (SIT), it has proven very effective in eradicating certain dipteran insect populations. However, when standard sterilization methods developed for dipertans are applied to mosquito populations significant complications arise, such as an inability to compete with non-irradiated males and high mortality rates. We have investigated the effect of treatment with x-rays of different wavelengths on x-ray sterilized mosquito males. Our results have demonstrated that longer wavelength x-rays have a significant effect on the outcome of the sterile males' longevity as well as an increase on the efficacy of sterilization while employing a substantially lower dose.

  11. The development of new radiation protocols for insect sterilization using long wavelength x-rays

    International Nuclear Information System (INIS)

    Urquidi, Jacob; Brar, Ramaninder K.; Rodriguez, Stacy; Hansen, Immo

    2015-01-01

    Control of insect species for the protection of crops, livestock, and prevention of disease such as dengue fever and malaria is a high priority in today’s global economy. Traditional methods such as pesticides have fallen out of favor because its effects are indiscriminate as well as adverse and unpredictable impacts on the environment. Modern novel techniques such as genetic modification have had trouble gaining traction due to ethics concerns and the potential for unforeseen side effects. One approach that has gained traction and has proven its efficacy is the use of ionizing radiation to affect sterility in insect species in order to scale back their population. Known as Sterile Insect Technique (SIT), it has proven very effective in eradicating certain dipteran insect populations. However, when standard sterilization methods developed for dipertans are applied to mosquito populations significant complications arise, such as an inability to compete with non-irradiated males and high mortality rates. We have investigated the effect of treatment with x-rays of different wavelengths on x-ray sterilized mosquito males. Our results have demonstrated that longer wavelength x-rays have a significant effect on the outcome of the sterile males’ longevity as well as an increase on the efficacy of sterilization while employing a substantially lower dose

  12. The development of new radiation protocols for insect sterilization using long wavelength x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Urquidi, Jacob, E-mail: jurquidi@nmsu.edu; Brar, Ramaninder K. [X-ray and Neutron Science Laboratory, Department of Physics, New Mexico State University, Las Cruces, NM (United States); Rodriguez, Stacy; Hansen, Immo [Molecular Vector Physiology Lab, Department of Biology, New Mexico State University, Las Cruces, NM (United States)

    2015-07-23

    Control of insect species for the protection of crops, livestock, and prevention of disease such as dengue fever and malaria is a high priority in today’s global economy. Traditional methods such as pesticides have fallen out of favor because its effects are indiscriminate as well as adverse and unpredictable impacts on the environment. Modern novel techniques such as genetic modification have had trouble gaining traction due to ethics concerns and the potential for unforeseen side effects. One approach that has gained traction and has proven its efficacy is the use of ionizing radiation to affect sterility in insect species in order to scale back their population. Known as Sterile Insect Technique (SIT), it has proven very effective in eradicating certain dipteran insect populations. However, when standard sterilization methods developed for dipertans are applied to mosquito populations significant complications arise, such as an inability to compete with non-irradiated males and high mortality rates. We have investigated the effect of treatment with x-rays of different wavelengths on x-ray sterilized mosquito males. Our results have demonstrated that longer wavelength x-rays have a significant effect on the outcome of the sterile males’ longevity as well as an increase on the efficacy of sterilization while employing a substantially lower dose.

  13. Influence of autoclave sterilization on the surface parameters and mechanical properties of six orthodontic wires.

    Science.gov (United States)

    Pernier, C; Grosgogeat, B; Ponsonnet, L; Benay, G; Lissac, M

    2005-02-01

    Orthodontic wires are frequently packaged in individual sealed bags in order to avoid cross-contamination. The instructions on the wrapper generally advise autoclave sterilization of the package and its contents if additional protection is desired. However, sterilization can modify the surface parameters and the mechanical properties of many types of material. The aim of this research was to determine the influence of one of the most widely used sterilization processes, autoclaving (18 minutes at 134 degrees C, as recommended by the French Ministry of Health), on the surface parameters and mechanical properties of six wires currently used in orthodontics (one stainless steel alloy: Tru-Chrome RMO; two nickel-titanium shape memory alloys: Neo Sentalloy and Neo Sentalloy with Ionguard GAC; and three titanium-molybdenum alloys: TMA(R) and Low Friction TMA Ormco and Resolve GAC). The alloys were analysed on receipt and after sterilization, using surface structure observation techniques, including optical, scanning electron and atomic force microscopy and profilometry. The mechanical properties were assessed by three-point bending tests. The results showed that autoclave sterilization had no adverse effects on the surface parameters or on the selected mechanical properties. This supports the possibility for practitioners to systematically sterilize wires before placing them in the oral environment.

  14. Microscope sterility during spine surgery.

    Science.gov (United States)

    Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J

    2012-04-01

    Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact

  15. Gamma-ray irradiation, autoclave and ethylene oxide sterilization to thermosetting polyurethane: sterilization to polyurethane

    International Nuclear Information System (INIS)

    Hirata, Noriko; Matsumoto, Ken-Ichi; Inishita, Takashi; Takenaka, Yoshinori; Suma, Yasunori; Shintani, Hideharu; National Inst. of Health Sciences, Tokyo

    1995-01-01

    Thermosetting polyurethane (PU) is widely used in a large variety of medical devices. 4,4'-methylenedianiline (MDA) was produced from PU by sterilization and it was studied for the relationship between urethane components or polymer characteristics and formation of MDA upon sterilization, using the commercially available dialyzers fabricated with different combination of isocyanate and polyol. We confirmed that the molecular-weight of polyol influenced the production of MDA upon sterilization. (author)

  16. A review: radiation sterilization of pharmaceuticals

    International Nuclear Information System (INIS)

    Jacobs, G.P.

    1985-01-01

    The literature on the effects of γ-radiation on drugs, relevant to their sterilization or decontamination, is reviewed. This literature survey essentially covers the past 7 yr, although relevant reports not covered in previous reviews have been included. (author)

  17. Radiation sterilization of animal farm sewage

    International Nuclear Information System (INIS)

    Rosiak, J.; Perkowski, J.; Pekala, W.

    1984-01-01

    Influence of irradiation on organisms appearing in farm sewage has been discussed. Practical examples of employing the radiation to sterilization of municipal wastes and liquid sewage from the industrial swine farms have been presented. (author)

  18. Determination of sterilizing dose of lincocine drug

    International Nuclear Information System (INIS)

    Adawi, M.A.; Shamma, M.; Al-Mousa, A.

    1998-01-01

    There are too many antibiotics that have been studied on their dry solid state to determine their safe sterilizing dose by decreasing their bio burden in order to reach the sterility assurance level (SAL) needed. The sterilizing radiating dose of lincocine was determined according to information about their bio burden and radiating sensitivity at the sterility assurance level 10-6. The study of bio burden has shown that the contamination was fungal (Pemicillium sp.) and by applying the same tests to the raw materials of lincocine it came out that the cause of contamination was bad storage and that the radiating dose required to decrease the bio burden was 5.5 kGy. (author)

  19. Searching for Sterile Neutrinos with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Timmons, Ashley [Manchester U.

    2016-01-01

    This document presents the latest results for a 3+1 sterile neutrino search using the $10.56 \\times 10^{20}$ protons-on-target data set taken from 2005 - 2012. By searching for oscillations driven by a large mass splitting, MINOS is sensitive to the existence of sterile neutrinos through any energy dependent deviations using a charged current sample, as well as looking at any relative deficit between neutral current events between the far and near detectors. This document will discuss the novel analysis that enabled a search for sterile neutrinos setting a limit in the previously unexplored regions in the parameter space $\\{\\Delta m^{2}_{41}, \\sin^2\\theta_{24}\\}$. The results presented can be compared to the parameter space suggested by LSND and MiniBooNE and complements other previous experimental searches for sterile neutrinos in the electron neutrino appearance channel.

  20. Methods of sterilization and monitoring of sterilization across selected dental practices in karachi, pakistan

    International Nuclear Information System (INIS)

    Ahmed, H.

    2015-01-01

    To assess methods of sterilization in dental practices in Karachi and secondly to investigate methods of monitoring sterilization in dental practices in Karachi, Pakistan. Study Design: Cross-sectional, descriptive study. Place and Duration of Study: Dental colleges, hospitals and private clinics of Karachi, Pakistan, from January to March 2013. Methodology: A total of 251 questionnaires were obtained. Descriptive statistics were computed and differences between groups were assessed through chi-square test using Statistical Package for the Social Sciences (SPSS) version 16.0. P-value < 0.05 was taken as statistically significant. Results: Autoclave, used by 155 (61.8%) dentists was the most common method of sterilization followed by more than one method, 65 (25.9%); dry heat, 24 (9.6%); and cold sterilization, 7 (2.8%). Majority of dentists, 126 (50.1%), never monitored sterilization and those who did monitored mostly monthly. Statistically significant difference was found amongst the three groups of dentists monitoring sterilization (p=0.09) and methods of sterilization (p < 0.01). Conclusion: Statistically significant difference was found in infection control practices of specialists, postgraduate trainees and general dentists regarding method of monitoring sterilization with majority of dentists never monitoring sterilization. (author)

  1. 21 CFR 522.1862 - Sterile pralidoxime chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile pralidoxime chloride. 522.1862 Section 522....1862 Sterile pralidoxime chloride. (a) Chemical name. 2-Formyl-1-methylpyridinium chloride oxime. (b) Specifications. Sterile pralidoxime chloride is packaged in vials. Each vial contains 1 gram of sterile...

  2. Sterilization of instruments in solar ovens

    Energy Technology Data Exchange (ETDEWEB)

    Fjendbo Joergensen, A. [Odense Univ. Hospital, Dept. of Infectious Diseases, Odense (Denmark); Noehr, K. [Odense Technical College, Dept. of Metal, Odense (Denmark); Boisen, F. [The Danish Veterinary and Food Administration Funen, Dept. of Microbiology, Odense (Denmark)

    2000-07-01

    The sterilization of instruments in rural health clinics in less developed countries is an increasing problem because chemical methods can no longer be recommended and wood fuel is becoming more and more scarce. Thus, it seemed obvious to try to utilize solar energy for sterilization purposes. A solar oven was designed and manufactured using local materials and simple tools. The solar oven was tested by physical, chemical, and microbiological methods. A mathematical model for the sterilization effect was developed and programmed into a microprocessor that was connected to a thermocouple. The microprocessor switches on a green light when the sterilization is completed. After successful testing, the oven was built into the west-facing wall of a rural health clinic and used daily for sterilization. The oven was able to generate temperatures above 180 deg. C. On all days with direct sunlight the oven fulfilled the international recommendations for hot air sterilization because no growth could be detected from any of the test bacteria spores. The chemical indicators Brownes tubes types 3 and 5 also changed colours. The solar oven was easy to use for the clinic staff, but during the seasons with low sun position (in Tanzania, December and June) it was difficult to achieve a high enough temperature for sterilization. Therefore, if the method is to be used throughout the year the oven must be moved to collect the sun's rays from several directions, or the clinic must have more than one solar oven facing in different directions. We conclude that the solar oven is a realistic method for sterilization of instruments. (au)

  3. Radiation sterilization of potato starch and Sedonik

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Ismatov, N.B.; Saidov, R.P. et al.

    2016-01-01

    The raw material of pharmaceutical preparations potato starch and sedative means of Sedonik are sterilized at the electron's accelerator Electronics U-003. It is established that at 20.3 kGy absorbed dose and electron's energy 3 - 5 MeV the results of microbiological analysis showed sterility of potato starch and Sedonik and correspondence of their physical-optical properties to the requirements of normative documents. (authors)

  4. Production of a sterile species: Quantum kinetics

    Science.gov (United States)

    Boyanovsky, D.; Ho, C. M.

    2007-10-01

    Production of a sterile species is studied within an effective model of active-sterile neutrino mixing in a medium in thermal equilibrium. The quantum kinetic equations for the distribution functions and coherences are obtained from two independent methods: the effective action and the quantum master equation. The decoherence time scale for active-sterile oscillations is τdec=2/Γaa, but the evolution of the distribution functions is determined by the two different time scales associated with the damping rates of the quasiparticle modes in the medium: Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where Γaa is the interaction rate of the active species in the absence of mixing and θm the mixing angle in the medium. These two time scales are widely different away from Mikheyev-Smirnov-Wolfenstein resonances and preclude the kinetic description of active-sterile production in terms of a simple rate equation. We give the complete set of quantum kinetic equations for the active and sterile populations and coherences and discuss in detail the various approximations. A generalization of the active-sterile transition probability in a medium is provided via the quantum master equation. We derive explicitly the usual quantum kinetic equations in terms of the “polarization vector” and show their equivalence to those obtained from the quantum master equation and effective action.

  5. Design of good manufacturing facility for sterile radioactive pharmaceuticals

    International Nuclear Information System (INIS)

    Shin, B.C.; Choung, W.M.; Park, S.H.; Lee, K.I.; Park, J.H.; Park, K.B.

    2002-01-01

    Based on the GMP codes for radiopharmaceuticals in U.K. and some advanced countries, suitable guidelines for the production facility have been established and followed them up. The facility designs were fairly modified to maintain cleanliness criteria for installation in the existing radioisotope production facilities which are installed only in radiation safety points of view. Detailed design brief was drawn up by the Hyundai Engineering staffs, on the basis of initial planning and conceptual design was carried out by authors. Hot cells were installed in preparation room for radioactive handling. As hot cells under negative air pressure are not properly airtight, the surrounding environment was designed to keep less than class 10,000. Hot cells were designed to maintain less than class 1 0,000 and partially less than class 1 00 for production of sterile products. Final products will be autoclaved for sterilization after filling. To avoid contamination by microorganisms and particles of surrounding area, air curtain with vertical laminar flow will be installed between anteroom and corridor. In a pharmaceutical environment, the main consideration is the protection of the product. Thus, work station is held above ambient pressure. However, when handling radioactive materials, air pressure for work station should be lower than in surrounding areas to protect the operators and the remainder of the facility from airborne radioactive contamination. As Radiopharmaceuticals are radioactive materials for medical use, changing room could be held higher pressure than any other zones. It is expected that the facility will be effectively used for both routine preparation and research for sterile radiopharmaceuticals. (Author)

  6. Voluntary sterilization in Serbia: Unmet need?

    Directory of Open Access Journals (Sweden)

    Rašević Mirjana M.

    2002-01-01

    Full Text Available Is voluntary sterilization as a birth control method accepted in Serbia? This is certainly a question that is being imposed for research, regardless of the fact that voluntary sterilization is neither accessible nor promoted. Most importantly because there is no understanding in the social nor political sphere for legalization of voluntary sterilization as a form of birth control, apart from the clear necessity for this, first, step. They are: the recognition that voluntary sterilization is an efficient and safe birth control method, respectability of basic human as well as sexual and reproductive rights, spreading of sterilization as a form of birth control among population of both developed and developing countries and an epidemic diffusion of repeated induced abortions in Serbia. Thus individual recognition of the advantages of relying on voluntary sterilization, in a non-encouraging atmosphere, certainly represents one more argument to enable couples to prevent conception by sterilization. Since it was impossible to carry out a representative research among the population of men and women who are at risk for conception, an attempt was made to obtain a reply to the set question among women who decided to induce abortion. It was done out of at least two reasons. The first being that women with induced abortion in their reproductive history were the target group for voluntary sterilization. The second reason was based on the assumption that bringing a decision on induced abortion is preceded by the reconsideration of an earlier adopted strategy regarding children, giving birth and contraception and thus its rational component is revealed more and therefore more easily measurable. The research was carried out in the University Clinic of Obstetrics and Gynecology 'Narodni front' in Belgrade from January 21st o March 1st 2002, and included 296 women. By comparing the social and demographic characteristics of the female respondents, as well as

  7. Field trials in South China to control the diamondback moth, Plutella xylostella (Lepidoptera: Plutellidae) using radiation-induced sterility

    International Nuclear Information System (INIS)

    Yang, R.; Xia, D.; Gu, W.; Zhang, Y.

    2002-01-01

    This paper discusses the control of the diamondback moth, Plutella xylostella by the sterile insect technique (SIT). Our studies included mating characteristics, sterility of the F 1 generation, dispersal and recapture of irradiated moths, as well as control of DBM using SIT and F 1 sterility, and an economic evaluation of F 1 sterility to protect cabbage. Male DBM mated an average of 16 times and female DBM mated an average of 4 times. However, irradiated male DBM only mated an average of 7.2 times. Seventy percent of matings occurred from 18:00-24:00 h with an average duration of 80 min. Irradiated male moths and untreated male moths exhibited the same attraction to female moths. After 10 days, most (94.2%) of the released, sterile DBM were recaptured within 40 m of the release site. Only one DBM was recaptured at 120 m from the release site. The area of dispersal was calculated to be 696 m 2 during the first three days. In a field study to control DBM by releases of irradiated insects, the ratio of sterile to wild DBM was 4.7:1. During this study, the egg sterility in the F 1 and F 2 generations was 79.0% and 81.7%, respectively. The developmental times for the F 1 and F 2 generations were 4 and 12 days longer, respectively, than for DBM in the control area. Thus, the number of DBM generations was reduced in the treated field. With successive releases over two generations, the control effectiveness was 80.8% in the F 1 generation and 79.1% in the F 2 generation. The cost of using F 1 sterility to control DBM in a small field was similar to the cost of using pesticides. Therefore, the use of F 1 sterility should be an economically viable control strategy for DBM that also would help protect the environment from the overuse of pesticides. (author)

  8. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene

    OpenAIRE

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-01-01

    Nuclear male sterility is common in flowering plants, but its application in hybrid breeding and seed production is limited because of the inability to propagate a pure male sterile line for commercial hybrid seed production. Here, we characterized a rice nuclear gene essential for sporophytic male fertility and constructed a male sterility system that can propagate the pure male sterile seeds on a large scale. This system is fundamentally advantageous over the current cytoplasmic male steril...

  9. Better health care: Ghana uses radiation technology to sterilize medical items

    International Nuclear Information System (INIS)

    Dixit, Aabha

    2015-01-01

    Infections acquired from improperly sterilized equipment are recognized as a major impediment to safe health care delivery, with consequences that are often deadly for patients. Radiation technology plays a major role in many countries in making medical equipment safer. “The use of nuclear applications, such as exposing medical items to gamma radiation, helps Ghana protect its people from avoidable sicknesses that can occur if items like syringes are not properly sterilized,” said Abraham Adu-Gyamfi, Manager of the Radiation Technology Centre of the Ghana Atomic Energy Commission’s Biotechnology and Nuclear Agriculture Research Institute in Accra.

  10. Sterility and property of norecoverable medical items from non-woven fabric

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Ismatov, N.B.; Makhkamov, Sh.M.; Saidov, R.P.; Abdulmanov, R.G.

    2014-01-01

    Full text: The purpose of present study is determination of the sterilization dose of surgery coat and sheet from spanbond-meltbond-spanbond material with minimum deviation of initial strength value. All seams of this surgery coat are sewed by dual insertion and soldered by ultrasonic solder for strenthening of the protective-barrier properties. It is established that after the radiation sterilization of disposable surgery coat at dose 20 kGy the breaking load of material lengthwise and width corresponds to permissible standards

  11. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice

    NARCIS (Netherlands)

    El-Namaky, R.; Oort, van P.A.J.

    2017-01-01

    Background: There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two

  12. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice.

    Science.gov (United States)

    El-Namaky, R; van Oort, P A J

    2017-12-01

    There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two EGMS lines tested here, it was not clear if one or more recessive gene(s) were causing male sterility. This was tested by studying sterility segregation of the F2 populations. Daylength (photoperiod) and minimum temperatures during the period from panicle initiation to flowering had significant effects on male sterility. Results clearly showed that only one recessive gene was involved in causing male sterility. The model was applied to determine the set of sowing dates of two different EGMS lines such that both would flower at the same time the pollen would be completely sterile. In the same time the local popular variety (Sahel 108, the male pollen donor) being sufficiently fertile to produce the hybrid seeds. The model was applied to investigate the viability of the two line breeding system in the same location with climate change (+2oC) and in two other potential locations: in M'Be in Ivory Coast and in the Nile delta in Egypt. Apart from giving new insights in the relation between environment and EGMS, this study shows that these insights can be used to assess safe sowing windows and assess the suitability of sterility and fertility period of different environments for a two line hybrid rice production system.

  13. Sterile insect supply, emergence, and release

    International Nuclear Information System (INIS)

    Dowell, R.V.; Worley, J.; Gomes, P.J.

    2005-01-01

    Insect mass-rearing for a sterile insect technique (SIT) programme is designed to move beyond the large-scale rearing of insects in a laboratory to the industrial production of consistently high-quality insects for sterilization and release. Each facility reflects the unique biology of the insect reared within it, but there are some generalities for all rearing facilities. Rearing insects in self-contained modules offers flexibility, and increased safety from catastrophic occurrences, compared with using a single building which houses all facets of the rearing process. Although mechanizing certain aspects of the rearing steps helps provide a consistently high-quality insect, successful mass-rearing and delivery depends largely upon the human component. Besides production in centralized facilities, insects can be produced from purchased eggs, or nowadays, adult insects are often obtained from specialized satellite emergence/collection facilities. Interest in commercializing insect production and release is increasing. Shipping sterile insects, sometimes over long distances, is now common practice. Procedures for handling and chilling adult insects, and providing food and water prior to release, are continually being improved. Sterile insects are released via static-release receptacles, ground-release systems, or most commonly from the air. The aerial release of chilled sterile insects is the most efficient method of release, especially when aircraft flight paths are guided by a Global Positioning System (GPS) linked to a computer-controlled release mechanism. (author)

  14. Gamma radiation sterilized amnion: use in ophthalmology

    International Nuclear Information System (INIS)

    Martinez P, M. E.; Leon T, Y.; Vazquez M, L.

    2010-10-01

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with 60 Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  15. Gamma radiation sterilized amnion: use in ophthalmology

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Leon T, Y. [Hospital General Regional 220, IMSS, Paseo Tollocan No. 620, Col. Vertice, Toluca 50150, Estado de Mexico (Mexico); Vazquez M, L., E-mail: esther.martinez@inin.gob.m [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06720 Mexico D. F. (Mexico)

    2010-10-15

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with {sup 60}Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  16. Sterilization and disinfection: the prevailing indifference

    International Nuclear Information System (INIS)

    Mirza, I.

    2007-01-01

    To evaluate the knowledge and attitude of health care professionals towards the process of sterilization and disinfection, and to check the adequacy of the reading material accessible to them. The study comprised of three components. In the first part, sections devoted to this subject in the popular books read by the students of operation theatre assistant course and students of diploma in general nursing were examined for adequacy and authenticity of information. In the second part, standard operating procedures were examined regarding sterilization of textile, rubber tubes of suction units and diathermy hand pieces of 20 operation theatres of three teaching hospital attached to undergraduate medical college of Punjab. In the third part of the study, working knowledge of 64 practicing operation theatre assistants and 57 practicing nurses was assessed through a questionnaire. It was found that popular books either did not contain the required information or the information provided was misleading or incorrect. Standard operating procedures for sterilization of selected items of all the operation theatres studied fell much below the standard of practice desired in the light of current knowledge and contemporary practices. Finally the working knowledge of the professionals studied was much below the bare minimum expected by the profession. There is a dire need for upgrading the knowledge and attitude of health care professionals regarding sterilization, besides improving the operation theatres sterilization procedures. (author)

  17. Revisiting cosmological bounds on sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, Aaron C. [Institute for Particle Physics Phenomenology (IPPP), Department of Physics, Durham University, Durham DH1 3LE (United Kingdom); Martínez, Enrique Fernández [Departamento and Instituto de Física Teórica (IFT), UAM/CSIC, Universidad Autonoma de Madrid, C/ Nicolás Cabrera 13-15, E-28049 Cantoblanco, Madrid (Spain); Hernández, Pilar; Mena, Olga [Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Lattanzi, Massimiliano, E-mail: aaron.vincent@durham.ac.uk, E-mail: enrique.fernandez-martinez@uam.es, E-mail: m.pilar.hernandez@uv.es, E-mail: omena@ific.uv.es, E-mail: lattanzi@fe.infn.it [Dipartimento di Fisica e Science della Terra, Università di Ferrara and INFN, sezione di Ferrara, Polo Scientifico e Tecnologico, Edificio C Via Saragat, 1, I-44122 Ferrara (Italy)

    2015-04-01

    We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expected in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.

  18. Ionizing radiation for sterilization of medical products and biological tissues

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S K; Raghevendrarao, M K [Bhabha Atomic Research Centre, Bombay (India). Library and Technical Information Section

    1975-10-01

    The article reviews the deliberations of the International Symposium on Ionizing Radiation for Sterilization of Medical Products and Biological Tissues which was held during 9-13 December 1974 under the auspices of the IAEA at the Bhabha Atomic Research Centre, Bombay. 42 papers were presented in the following broad subject areas: (1) Microbiological Control aspects of radiation sterilization, (2) Dosimetry aspects of radiation sterilization practices, (3) Effects of sterilizing radiation dose on the constituents of medical products, (4) Application of radiation sterilization of medical products of biological origin, (5) Technological aspects of radiation sterilization facilities, (6) Radiation sterilization of pharmaceutical substances, (7) Reports on current status of radiation sterilization of medical products in IAEA member states and (8) Working group discussion on the revision of the IAEA recommended code of practice for radiation sterilization of medical products.

  19. Testing sterile neutrino extensions of the Standard Model at future lepton colliders

    Science.gov (United States)

    Antusch, Stefan; Fischer, Oliver

    2015-05-01

    Extending the Standard Model (SM) with sterile ("right-handed") neutrinos is one of the best motivated ways to account for the observed neutrino masses. We discuss the expected sensitivity of future lepton collider experiments for probing such extensions. An interesting testable scenario is given by "symmetry protected seesaw models", which theoretically allow for sterile neutrino masses around the electroweak scale with up to order one mixings with the light (SM) neutrinos. In addition to indirect tests, e.g. via electroweak precision observables, sterile neutrinos with masses around the electroweak scale can also be probed by direct searches, e.g. via sterile neutrino decays at the Z pole, deviations from the SM cross section for four lepton final states at and beyond the WW threshold and via Higgs boson decays. We study the present bounds on sterile neutrino properties from LEP and LHC as well as the expected sensitivities of possible future lepton colliders such as ILC, CEPC and FCC-ee (TLEP).

  20. Radiation Fusion Technology for Sewage Sterilization

    International Nuclear Information System (INIS)

    Lee, M. J.; Kim, T. H.; Ryu, S. H.; Jung, I. H.; Lee, O. M.; Kim, T. H.

    2011-01-01

    Environmental regulation for effluent of sewage and wastewater treatment plant is going to be reinforced in terms of ecology toxicity and number of E.coli from 2011. Besides, it has been known that UV technology is not enough to be a sterilization tool due to regrowth of E.coli even after treatment with UV. Therefore it needs a novel technology for both restriction of E.coli regrowth and treatment of toxic materials in order to meet the environmental regulation being enforced. Electron beam has unique capabilities on destruction of chemicals and sterilization of microbial. In this study, field study on destruction of antibiotics and endocrine disruptors, reduction ecological toxicity and E.Coli regrowth was carried out using by mobile electron beam accelerator. Experimental results showed that irradiation on effluent could effectively reduce not only ecology toxicity but regrowth of E.coli by destruction of chemicals and complete sterilization

  1. Mechanisms of male sterility in higher plants

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Yasuo [Tsukuba Univ., Sakura, Ibaraki (Japan)

    1982-03-01

    The mechanisms causing male sterility in higher plants were classified into two major categories: genetic and non-genetic. The former was further divided into six classes: 1) Anomality in spindle mechanism during meiosis, 2) chromosomal anomality such as haploidy, polyploidy, aneuploidy, chromosome some deficiency, inversion and reciprocal translocation, 3) presence of male sterile genes, 4) cytoplasmic abnormality, 5) the combination of some specific cytoplasm with particular genes, and 6) infections of microorganisms or viruses. Each mechanism was briefly explained, and the methods for the maintenance of parent lines for heterosis breeding and hybrid seed production were described. The non-genetic male sterility was classified into four types, which are caused by 1) low or high temperature, 2) water deficiency, 3) application of chemicals, and 4) radiation, with a brief explanation given for each of them.

  2. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards...... and documented uncertainty limits of the dose measurements can be used to specify process control limits. This is also useful, for example, when dose setting experiments are carried out according to the methods described in ISO 11137, where product samples shall be irradiated within narrow limits......., the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  3. Mechanisms of male sterility in higher plants

    International Nuclear Information System (INIS)

    Ohta, Yasuo

    1982-01-01

    The mechanisms causing male sterility in higher plants were classified into two major categories: genetic and non-genetic. The former was further divided into six classes: 1) Anomality in spindle mechanism during meiosis, 2) chromosomal anomality such as haploidy, polyploidy, aneuploidy, chromosome some deficiency, inversion and reciprocal translocation, 3) presence of male sterile genes, 4) cytoplasmic abnormality, 5) the combination of some specific cytoplasm with particular genes, and 6) infections of microorganisms or viruses. Each mechanism was briefly explained, and the methods for the maintenance of parent lines for heterosis breeding and hybrid seed production were described. The non-genetic male sterility was classified into four types, which are caused by 1) low or high temperature, 2) water deficiency, 3) application of chemicals, and 4) radiation, with a brief explanation given for each of them. (Kaihara, S.)

  4. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Vijaya Krishnan

    2004-12-01

    Full Text Available Prior to early 1970s, traditional methods were the principal means of controlling the number and spacing of births. Today, an estimated 57 per cent of the world’s married women use contraceptives and half use modern methods such as medical sterilizations. Recent statistics suggest that Canada has the highest sterilization rate in the Western world. This paper presents findings of research examining sterilization trends in Canada with respect to changing patterns in the use of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995 General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligation and an increase in the use of hysterectomy over the period 1984-1995. Less educated women are more likely to be in the forefront of modern methods of contraception.

  5. Ozone--the latest advance in sterilization of medical devices.

    Science.gov (United States)

    Murphy, Lorna

    2006-06-01

    How many times have procedures in your operating rooms been delayed because the instruments needed were still in the sterilizer? As Perioperative nurses you are likely to be quite familiar with the constant pressure to ensure that scarce instrumentation is available when needed. In 2003, a Canadian company developed a unique sterilization process employing ozone as the sterilizing agent. This technology is a safe, rapid and economical alternative to other low temperature sterilization modalities and may relieve some of the pressure experienced when instruments in short supply are in high demand. This article will discuss the principles of the sterilizer and the cycle and will explore the advantages of using this sterilization technology.

  6. Sterilization processes. Meeting the demands of today's health care technology.

    Science.gov (United States)

    Crow, S

    1993-09-01

    Universal Precautions dictate sterilization for all invasive equipment that break the blood barrier; however, current methods of sterilization, such as steam and ethylene oxide gas (ETO), are not compatible with many of the delicate, heat-sensitive surgical instruments used in modern health care. In addition, traditional sterilization methods are often too time consuming for practical use in the operating room. Clearly, new sterilization processes need to be developed. In this article, the criteria modern sterilization processes must meet and how some manufacturers plan to meet this challenge are discussed. In addition, the pros and cons of using peracetic acid (the newest sterilization process currently available) are examined.

  7. Dynamic sterilization of titanium implants with ultraviolet light

    International Nuclear Information System (INIS)

    Singh, S.; Schaaf, N.G.

    1989-01-01

    All implantable devices must be sterile. However, autoclaves produce poor surface properties that jeopardize the integration process. The application of a modified ultraviolet light source has proven to enhance bioreactivity by controlling surface properties, but it lacks validation of its sterilization capabilities. Forty-eight titanium implants were contaminated with spores of the biological indicator Bacillus stearothermophilus and subjected to dynamic sterilization by ultraviolet light. Forty-seven of the implants were successfully sterilized, as indicated by not producing turbidity in a suitable growth medium. This sterilization technique only requires a 20-second exposure to achieve sterility

  8. Induced mutant for male sterility in niger

    International Nuclear Information System (INIS)

    Sujatha, M.

    2001-01-01

    Full text: Niger (Guizotia abyssinica Cass.), an important oilseed crop of the family Compositae is highly cross-pollinated due to the twin mechanisms of protandry and incompatibility. Studies revealed the functional nature of protandry and the breakdown of incompatibility with alteration in temperature. It has very small flowers (disc florets) arranged in a capitulum that open on 3-4 consecutive days which pose problems in emasculation for cross-breeding. To induce mutations, seeds of variety 'IGP-76' were irradiated with γ-rays 200 to 1000 Gy. All seeds of M 1 plants were sown separately in individual plant-to progeny rows. The results of screening of M 2 segregating material indicated that γ-ray treatment was effective in induction of male sterility. Frequency of visible mutations were higher in sibbed progeny as compared to open pollinated population and male sterile plants were observed only in sibbed population (1000 Gy). Male sterile plants could easily be identified at the flowering stage by their altered floral morphology (disc florets transformed into ligulate ray florets) and complete absence or presence of a rudimentary anther column. Seeds were collected following sib-mating with the fertile counterparts. Progeny segregated in a ration of 3 normal : 1 male sterile. Further work on the mechanism of sterility, maintenance and linkage relationships with associated characters is under progress. This is the first report of induction of male sterility in niger through the use of physical mutagens. The availability of this mutant will be of great value for exploitation of heterosis on commercial basis. (author)

  9. Mass-rearing for sterile insect release

    International Nuclear Information System (INIS)

    Parker, A.G.

    2005-01-01

    As the sterile insect technique (SIT) relies upon released sterile male insects efficiently competing with wild males to mate with wild females, it follows that mass-rearing of insects is one of the principal steps in the process. Mass-rearing for the SIT presents both problems and opportunities due to the increased scale involved compared with rearing insects for most other purposes. This chapter discusses facility design, environmental concerns, strain management, quality control, automation, diet, sex separation, marking, and storage in relation to rearing for the SIT. (author)

  10. Radiation sterilization of pharmaceuticals (eg chloramphenicol)

    International Nuclear Information System (INIS)

    Zeegers, F.; Tilquin, B.

    1991-01-01

    In connection with the ongoing world-wide application of irradiation as a new technology for sterilization, the identification of the drugs products is very important. Introduction of radiosterilization of pharmaceuticals is proceeding at a slower rate than that for disposable medical supplies; it is the responsibility of the manufacturer to prove that degradation of products is safe. Major advantages in the use of radiation as a sterilization procedure are high penetrating power, small temperature rise, ease of control and minimal degradation of irradiated solid drugs [fr

  11. Nurses and the sterilization experiments of Auschwitz: a postmodernist perspective.

    Science.gov (United States)

    Benedict, Susan; Georges, Jane M

    2006-12-01

    The medical experiments conducted on non-consenting prisoners of Nazi concentration camps during World War II necessitated the codification of principles to protect human subjects of research. Auschwitz was the largest and one of the most infamous of the camps and the site of numerous 'medical' experiments. This historical study uses primary source documents obtained from archives in England and Germany to describe one type of experiment carried out at Auschwitz - the sterilization experiments. The purpose of these experiments was to perfect a technique in which non-Aryans could be prevented from reproducing while still being able to work as slave laborers. These narratives regarding the sterilization experiments at Auschwitz are remarkable in that they contain previously undocumented information regarding the voluntary and involuntary involvement of nurses. Following these narratives, a discussion of ethics in relation to the Holocaust is presented with a specific focus on the work of Agamben. Implications of the Auschwitz narratives for the application of codes of ethical principles and contemporary nursing are discussed from a postmodernist perspective.

  12. Present studies on the radio-sterilized drugs

    International Nuclear Information System (INIS)

    Marciniec, B.; Dettlaff, K.

    2007-01-01

    Lecture presents present status of radiosterilization of drugs and medical materials as compared to other sterilization methods. Literature review is shown on degradation of different kinds of drugs sterilized upon action of the sterilising doses of radiation

  13. Unintended pregnancies after Essure sterilization in the Netherlands

    NARCIS (Netherlands)

    Veersema, S.; Vleugels, M.P.; Moolenaar, L.M.; Janssen, C.A.; Brölmann, H.A.M.

    2010-01-01

    Objective: To analyze the data of cases of unintended pregnancies after Essure sterilization. Design: Retrospective case series analysis. Setting: National multicenter. Patient(s): Ten cases of unintended pregnancies after Essure sterilization in the Netherlands were reported from August 2002

  14. Bilateral cornual abscess after endometrial ablation following Essure sterilization.

    NARCIS (Netherlands)

    Jansen, N.E.; Vleugels, M.P.; Kluivers, K.B.; Vierhout, M.E.

    2007-01-01

    Endometrial ablation is used extensively to treat dysfunctional bleeding. Since the introduction of Essure tubal sterilization, this permanent contraception method has been widely used. Both endometrial ablation and Essure sterilization are procedures reported to have only a few complications. We

  15. Red oak borers become sterile when reared under continuous light

    Science.gov (United States)

    Jimmy R. Galford

    1975-01-01

    Red oak borers, Enaphalodes rufulus (Haldeman), reared under continuous light for 12 weeks became sterile. Sterility is thought to have been caused by light destroying vitamins essential for fertility

  16. Biological basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Lance, D.R.; McInnis, D.O.

    2005-01-01

    In principle, the sterile insect technique (SIT) is applicable to controlling a wide variety of insect pests, but biological factors, interacting with socio-economic and political forces, restrict its practical use to a narrower set of pest species and situations. This chapter reviews how the biology and ecology of a given pest affect the feasibility and logistics of developing and using the SIT against that pest insect. The subjects of pest abundance, distribution, and population dynamics are discussed in relation to producing and delivering sufficient sterile insects to control target populations. Pest movement and distribution are considered as factors that influence the feasibility and design of SIT projects, including the need for population- or area-wide management approaches. Biological characteristics, that affect the ability of sterile insects to interact with wild populations, are presented, including the nature of mating systems of pests, behavioural and physiological consequences of mass production and sterilization, and mechanisms that males use to block a female's acquisition and/or use of sperm from other males. An adequate knowledge of the biology of the pest species and potential target populations is needed, both for making sound decisions on whether integration of the SIT into an area-wide integrated pest management (AW-IPM) programme is appropriate, and for the efficient and effective application of the technique. (author)

  17. Gamma radiation sterilization of Bactrocera invadens (Diptera ...

    African Journals Online (AJOL)

    The African invader fly, Bactrocera invadens, an invasive pest in Africa since 2003, causes damage and poses a threat to the mango and horticultural industry. Its control is therefore needed. Sterilization of males using gamma radiation doses (25, 50 and 75 Gy) as a means of population control was investigated. Irradiation ...

  18. Sterilization of heparinized cuprophan hemodialysis membranes

    NARCIS (Netherlands)

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated.

  19. Heat sterilization times of five hardwood species

    Science.gov (United States)

    William T. Simpson; Xiping Wang; John W. Forsman; John R. Erickson

    2005-01-01

    Heat sterilization of lumber, timbers, and pallets is currently used to kill insects, thus preventing their transfer between countries in international trade. An important factor in this treatment is the time required for the center of any wood configuration to reach the temperature necessary to kill the insect. This study explored the effect of size (1-, 1.5-, and 2.0...

  20. Sterilization of spices through ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Heins, H G; Ulmann, R M

    1971-10-01

    Sterilization of spices is discussed in relation to other methods. Efficiency, organoleptic inspection and costs of the treatment are considered. It is concluded that the irradiation method is feasible and acceptable with respect to taste and juridicial requirements. (G.J.P.). 12 refs.; 1 figure; 4 tabs.

  1. Perspectives: Eugenics and Sterilization in the Heartland.

    Science.gov (United States)

    Wehmeyer, Michael L.

    2003-01-01

    Noting the Governor of Virginia's recent apology for his state's participation in eugenics, this article reviews the history of the sterilization of people with epilepsy and mental retardation in several states, and the importance of the Buck v. Bell (1927) Supreme Court decision in the promotion of eugenics. (Contains references.) (CR)

  2. Utilization of male sterility in forage crops

    International Nuclear Information System (INIS)

    Suginobu, Ken-ichi

    1982-01-01

    The genetic nature of male sterility in forage crops was reviewed. Many workers have suggested that hybrids in forage crops are quite promising. First, the selection of the most desirable parental genotype from a large original population is improtant in heterosis breeding programs. After the more promising inbreds or clones have been selected on the basis of good general combining ability, it is necessary to identify the particular single, three-way or double cross that will produce the highest yields. A high seed yield potential is also important in a new variety so that the seeds can be sold at lower prices than other varieties. A tentative scheme for hybrid seed production by using inbred lines of male sterile or normal parents is proposed. At a breeding station, the seeds for male sterile F 1 (AB), maintainer S 1 (C-S 1 ) and either maintainer or restorer S 1 s(D-S 1 , E-S 1 ) are produced from the parental clones. At a seed increase agency, the seeds for male sterile F 1 (ABC) and either maintainer or restorer S 2 (D-S 2 ) are produced. In the case that D-S 2 seed production is difficult, maintainer or restorer F 1 (DE) should be produced from D-S 1 x E-S 1 . These seeds are used for commercial seed production. Seeds of hybrid F 1 (ABCD) or hybrid F 1 (ABCDE) are for practical use. (Kaihara, S.)

  3. Process variation in electron beam sterilization

    International Nuclear Information System (INIS)

    Beck, Jeffrey A.

    2012-01-01

    The qualification and control of electron beam sterilization can be improved by the application of proven statistical analysis techniques such as Analysis of Variance (ANOVA) and Statistical Tolerance Limits. These statistical techniques can be useful tools in: •Locating and quantifying the minimum and maximum absorbed dose in a product. •Estimating the expected process maximum dose, given a minimum sterilizing dose. •Setting a process minimum dose target, based on an allowance for random measurement and process variation. •Determining the dose relationship between a reference dosimeter and process minimum and maximum doses. This study investigates and demonstrates the application of these tools in qualifying electron beam sterilization, and compares the conclusions obtained with those obtained using practices recommended in Guide for Process Control in Radiation Sterilization. The study supports the following conclusions for electron beam processes: 1.ANOVA is a more effective tool for evaluating the equivalency of absorbed doses than methods suggested in . 2.Process limits computed using statistical tolerance limits more accurately reflect actual process variability than the AAMI method, which applies +/−2 sample standard deviations (s) regardless of sample size. 3.The use of reference dose ratios lends itself to qualification using statistical tolerance limits. The current AAMI recommended approach may result in an overly optimistic estimate of the reference dose adjustment factor, as it is based on application of +/−2(s) tolerances regardless of sample size.

  4. Sterilization of Microorganisms by Ozone and Ultrasound

    Science.gov (United States)

    Krasnyj, V. V.; Klosovskij, A. V.; Panasko, T. A.; Shvets, O. M.; Semenova, O. T.; Taran, V. S.; Tereshin, V. I.

    2008-03-01

    The results of recent experimental methods of sterilization of microorganisms with the use of ozone and ultrasound are presented. The main aim was to optimize the process of sterilization in water solution taking into account the ozone concentration, the power of ultrasonic emitter and the temperature of water. In the present work, the ultrasonic cavitation with simultaneous ozone generation has been used. The high ozone concentration in water solution was achieved by two-barrier glow discharge generated at atmospheric pressure and a cooling thermo-electric module. Such a sterilizer consists of ozone generator in a shape of flat electrodes covered with dielectric material and a high-voltage pulsed power supply of 250 W. The sterilization camera was equipped with ultrasonic source operated at 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. The ozone concentration in the aqueous solution was 10 mg/1, whereas the ozone concentration at the output of ozone generator was 30 mg/1. The complete inactivation of spores took 15 min. Selection of the temperature of water, the ozone concentrations and ultrasonic power allowed to determine the time necessary for destroying the row of microorganisms.

  5. Whey powder sterilization by ionizing irradiation

    International Nuclear Information System (INIS)

    Todorovic, M.; Salatic, Z.; Markov, S.

    1988-01-01

    Whey powder was sterilized by gamma waves application. As a source of irridiation isotope 60Co was used in Institute of Nuclear sciences B oris Kidrich , Vincha-Belgrade (Yugoslavia). The applied doses were: a, b, c, d, and e Kgy. The dose d was radappertization. After whey powder irradiation no adverse changes of organoleptic properties were noticed

  6. Methods of medical sterilization; Metody sterylizacji medycznej

    Energy Technology Data Exchange (ETDEWEB)

    Stachowicz, W [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    Broad review of different (physical, chemical and mechanical) methods commonly used for medical materials sterilization have been performed. Among them the special attention have been played on radiosterilization. The advantages and weaknesses each of the presented method have been pointed out. 1 fig.

  7. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    International Nuclear Information System (INIS)

    Parker, A.; Mehta, K.

    2007-01-01

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discuss optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [es

  8. Status of radiation sterilization of healthcare products in China

    International Nuclear Information System (INIS)

    Zhu Nankang; Wang Chunlei; Teng Weifang

    2004-01-01

    This paper describes the status of 60 Co radiation facilities both in service and under construction in China and examines the future market for radiation sterilization of healthcare products. Policies for developing the industry of radiation sterilization are also put forward; these include implementation of appropriate quality systems, scale-up and merging of existing radiation facilities, development of electron beam radiation for sterilization purposes and increasing awareness of the technology of radiation sterilization

  9. Laparoscopic tubal sterilization reversal and fertility outcomes

    Directory of Open Access Journals (Sweden)

    K Jayakrishnan

    2011-01-01

    Full Text Available Purpose: The purpose of the study was two-fold. Firstly it was to assess the suitability for tubal recanalization and factors predicting successful laparoscopic recanalization. Secondly, it was to analyze the fertility outcomes and factors affecting the pregnancy rate following laparoscopic tubal recanalization. Materials and Methods: A retrospective chart review of prospectively followed-up 29 women at a tertiary care center seeking tubal sterilization reversal between May 2005 and February 2010 were included. Results: In 14 (48.3% women unilateral tubes were suitable and in only 3 women (10.3% bilateral tubes were suitable. All cases with laparoscopic tubal sterilization were suitable, whereas all cases with fimbriectomy were unsuitable for recanalization. In 6 (20.7% cases salphingostomy was performed as an alternative procedure to tubal reanastomosis. The overall pregnancy rate was 58.8%. In cases with sterilization by Pomeroy′s method, 4 out of 10 (40% conceived, whereas for laparoscopic tubal ligation cases 6 out of 7 (85.7% conceived (P=0.32. None of the patients with final tubal length <5 cm conceived (P=0.03. Comparing the age at recanalization, in women ≤30 years, 71.4% conceived, as compared with 50% when age of women was more than 30 years (P=0.37. Conclusions: The important factors determining the success of recanalization are technique of sterilization and the remaining length of the tube after recanalization. The gynecologist must use an effective technique of sterilization to minimize the failure rates, but at the same time, which causes minimal trauma, and aim at preserving the length of the tube so that reversal is more likely to be successful, should the patient′s circumstances change.

  10. Device and Container for Reheating and Sterilization

    Science.gov (United States)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  11. Production of a sterile species via active-sterile mixing: An exactly solvable model

    Science.gov (United States)

    Boyanovsky, D.

    2007-11-01

    The production of a sterile species via active-sterile mixing in a thermal medium is studied in an exactly solvable model. The exact time evolution of the sterile distribution function is determined by the dispersion relations and damping rates Γ1,2 for the quasiparticle modes. These depend on γ˜=Γaa/2ΔE, with Γaa the interaction rate of the active species in absence of mixing and ΔE the oscillation frequency in the medium without damping. γ˜≪1, γ˜≫1 describe the weak and strong damping limits, respectively. For γ˜≪1, Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where θm is the mixing angle in the medium and the sterile distribution function does not obey a simple rate equation. For γ˜≫1, Γ1=Γaa and Γ2=Γaasin⁡22θm/4γ˜2, is the sterile production rate. In this regime sterile production is suppressed and the oscillation frequency vanishes at an Mikheyev-Smirnov-Wolfenstein (MSW) resonance, with a breakdown of adiabaticity. These are consequences of quantum Zeno suppression. For active neutrinos with standard model interactions the strong damping limit is only available near an MSW resonance if sin⁡2θ≪αw with θ the vacuum mixing angle. The full set of quantum kinetic equations for sterile production for arbitrary γ˜ are obtained from the quantum master equation. Cosmological resonant sterile neutrino production is quantum Zeno suppressed relieving potential uncertainties associated with the QCD phase transition.

  12. Cost-effectiveness analysis comparing the essure tubal sterilization procedure and laparoscopic tubal sterilization.

    Science.gov (United States)

    Thiel, John A; Carson, George D

    2008-07-01

    To analyze the financial implications of establishing a hysteroscopic sterilization program using the Essure micro-insert tubal sterilization system in an ambulatory clinic. A retrospective cohort study (Canadian Task Force classification Type II-2), in an ambulatory women's health clinic in a tertiary hospital, of 108 women undergoing Essure coil insertion between 2005 and 2006, and 104 women undergoing laparoscopic tubal sterilization for permanent sterilization between 2001 and 2004. The Essure procedures used a 4 mm single channel operative hysteroscope and conscious sedation (fentanyl and midazolam); the laparoscopic tubal sterilizations were completed under general anaesthesia with a 7 mm laparoscope and either bipolar cautery or Filshie clips. Costs associated with the procedure, follow-up, and management of any complications (including nursing, hospital charges, equipment, and disposables) were tabulated. The Essure coils were successfully placed on the first attempt in 103 of 108 women (95%). Three patients required a second attempt to complete placement and two patients required laparoscopic tubal sterilization after an unsuccessful Essure. All 104 laparoscopic tubals were completed on the first attempt with no complications reported. The total cost for the 108 Essure procedures, including follow-up evaluation, was $138,996 or $1287 per case. The total cost associated with the 104 laparoscopic tubal sterilization procedures was $148,227 or $1398 per case. The incremental cost-effectiveness ratio was $111. The Essure procedure in an ambulatory setting resulted in a statistically significant cost saving of $111 per sterilization procedure. Carrying out the Essure procedure in an ambulatory setting frees space in the operating room for other types of cases, improving access to care for more patients.

  13. The male gametophytic sterility. 1 - Gametic sterilities and deletions in petunia

    International Nuclear Information System (INIS)

    Cornu, A.; Maizonnier, D.

    1982-01-01

    Terminal deletions induced by ionizing radiations in Petunia are not sexually transmitted. Cytogenetic study of plants with a heterozygous deletion and their progenies shows that this lack of transmission is accompanied by a gametic semi-sterility due to the fact that gametes carrying the deleted chromosome are not viable. The interest of such a male sterility with a gametophytic determinism for the study of sporophyte-gametophyte relationships is underlined [fr

  14. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period (minutes) Directions T303-b-1 10 lbs 20 Use 28″ vacuum. Steam sterilization is not practical for treatment...

  15. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to...

  16. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by the...

  17. Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.

    Science.gov (United States)

    Mann, A; Kiefer, M; Leuenberger, H

    2001-03-01

    High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions.

  18. Sterilization of solutions for parenterals products. Problem analysis

    Directory of Open Access Journals (Sweden)

    Yanelys Montes-González

    2017-09-01

    Full Text Available The solutions for the formulation of parenteral products must be sterile before the aseptic formulation process. For this reason, different methods of sterilization referred in the literature are analyzed. Thermodynamic criteria that rule the sterilization are presented. Furthermore, previous experiences in the sterilization of solutions for the formulation of parental products in an autoclave are analyzed, that take large time of processing and only low volumes of solution can be handled. Using jacketed stirred tanks for the sterilization may solve the problem and, therefore, criteria for the design of the later that allow to process high volumes of solution for the formulation of parenteral products are shown.

  19. Radiation sterilization of medical products- current trends and future prospects

    International Nuclear Information System (INIS)

    Sharma, G.

    1997-01-01

    In medical practice use of sterile pharmaceuticals and single use disposable medical devices is steadily increasing. Sterile pharmaceuticals like injections and ophthalmic ointments are required for therapy. Medical devices are employed for diagnostic, drug administration or corrective purposes, and as implants for temporary, short term or long term residence in the human system. All these products are made available in sterile form by treating them to a suitable process of sterilization i.e. dry/wet heat, ethylene oxide (EtO) gas or ionizing radiation. In this paper current trends and future prospects of radiation sterilization of medical products are given in detail. 9 refs., 7 tabs

  20. Genetic complexity underlying hybrid male sterility in Drosophila.

    Science.gov (United States)

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-02-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic basis of hybrid male sterility more complex than that of hybrid female sterility and inviability? To clarify this point, the D. simulans introgression of the cytological region 34D-36A to the D. melanogaster genome, which causes recessive male sterility, was dissected by recombination, deficiency, and complementation mapping. The 450-kb region between two genes, Suppressor of Hairless and snail, exhibited a strong effect on the sterility. Males are (semi-)sterile if this region of the introgression is made homozygous or hemizygous. But no genes in the region singly cause the sterility; this region has at least two genes, which in combination result in male sterility. Further, the males are less fertile when heterozygous with a larger introgression, which suggests that dominant modifiers enhance the effects of recessive genes of male sterility. Such an epistatic view, even in the less-related species, suggests that the genetic complexity is special to hybrid male sterility.

  1. A search for sterile neutrinos in MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Osiecki, Thomas Henry [Univ. of Texas, Austin, TX (United States)

    2007-01-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining Δm$2\\atop{23}$ and θ23 through the disappearance of vμ, MINOS is able to measure vμ → vsterile by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS.

  2. Energy analysis in sterilization process of food

    International Nuclear Information System (INIS)

    Lee, Dong Sun; Pyun, Yu Ryang

    1986-01-01

    A procedure was developed for predicting energy consumption of batch type thermal processing of food. From mass and energy balance equations various energy usages or losses were estimated for steam sterilization of model food system in No.301-7 can (Φ74.1 x 113.0mm) at three different temperatures. Selected models were 5 % bentonite solution for conductive food and tap water for convective food. Total steam or energy consumption was higher at 110 deg C than at two other higher temperatures (121 deg C and 130 deg C). High energy consumption at low sterilization temperature was mainly due to high bleeding steam energy and convective and radiative heat losses. Thermal energy efficiency was also disscussed. (Author)

  3. Radiation sterilization of pharmaceuticals and polymers

    International Nuclear Information System (INIS)

    Gopal, N.G.S.

    1978-01-01

    Radiation, in the form of high energy electrons as well as gamma radiation, has featured in the last 15 yr as a promising sterilization agent for many heat sensitive and ethylene oxide incompatible pharmaceuticals and polymers of medical usage. This article deals with (i) a comparison of the various methods of sterilization and their shortcomings, (ii) modes of interaction of radiation with matter, (iii) the types of radiation sources in common use, (iv) dosimetry, (v) dose rate effect, (vi) a literature survey of the radiation effect on pharmaceuticals in solid form as well as in aqueous solution and on polymers in the form of plastic medical products and (vii) the evaluation of the irradiated products. The effect of dose rate on the stability of these materials is emphasized. Either very little work has been done on the dose rate effect or the published information is scanty. The literature survey covers the recent period of 5 to 6 years. (author)

  4. A search for sterile neutrinos in MINOS

    International Nuclear Information System (INIS)

    Osiecki, Thomas Henry

    2007-01-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining Δm 23 2 and θ 23 through the disappearance of ν μ , MINOS is able to measure ν μ → ν sterile by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS

  5. Radiation sterilization of triple sugar iron agar

    International Nuclear Information System (INIS)

    Altmann, G.; Eisenberg, E.; Bogokowsky, B.

    1979-01-01

    Triple sugar iron agar (TSI), a medium used for the identification of enteric bacteria, was sterilized by gamma radiation using radiation doses of 750-2000 krad. The radio-sterilized medium, slightly modified by increasing its Phenol Red content, performed well when tested with different enterobacteriaceae and other gram negative bacteria. Growth, change of indicator reaction in slant and butt and formation of gas and H 2 S were equal in irradiated and autoclaved TSI. Slants of irradiated TSI in stoppered plastic tubes kept their diagnostic properties during storage for at least 4 months. Gamma irradiation appears to be an attractive and economical method of sterilising nutrient media in sealed tubes or other containers, avoiding the risk of contamination during processing. (author)

  6. Radiation Sterilization of Naturual Rubber Examination Gloves

    International Nuclear Information System (INIS)

    Jetawattana, S.; Na-Ranong, N.; Kajornchaiyakul, V.

    1998-01-01

    The sterilization dose setting by ISO 11137 method 1 was conducted for natural rubber examination gloves provided by a local factory. The suitable sterilization dose for an average product bioburden falls between 20 - 25 kilogray. Maximum dose of 25 or 50 kilogray results in no changes of tensile s and elongation at break. Samples of examination glove were irradiated using various doses between 10 - 50 kilogray. Analysis of soluble protein content using modified Lowry method was carried out and the results revealed that irradiation did not affect the decrement of soluble protein content in this case. However, thin film samples were prepared in laboratory and treated in the same procedure. The results were also the same. The results did not show any correlation. Two factors are possibly presumed : un consistency of samples and the irradiation of finished products could not affect those soluble proteins in rubber gloves

  7. Surgical sterilization of free-ranging wolves.

    Science.gov (United States)

    Spence, C E; Kenyon, J E; Smith, D R; Hayes, R D; Baer, A M

    1999-02-01

    The objective of the study was to determine whether surgical sterilization of both males and females in wolf pairs alters basic wolf social and territorial behaviors. Wolves were located from the air by snow-tracking methods and were tranquilizer-darted from a helicopter. Surgeries were performed either in a tent at the capture site or in a heated building in a nearby village. Six vasectomies and seven uterine horn ligations were performed in January and February of 1996 and 1997. Two females died: one likely related to the capture procedure, the other of a peritonitis unrelated to the surgery. One wolf had a litter. None of the wolves have shown changes in behavioral patterns. Surgical sterilization can be effective, but other, less invasive, fertility control techniques should be investigated.

  8. Theoretical approach to the destruction or sterilization of drugs in aqueous solution

    International Nuclear Information System (INIS)

    Slegers, Catherine; Tilquin, Bernard

    2005-01-01

    Two novel applications in the radiation processing of aqueous solutions of drugs are the sterilization of injectable drugs and the decontamination of hospital wastewaters by ionizing radiation. The parameters influencing the destruction of the drug in aqueous solutions are studied with a computer simulation program. This theoretical approach has revealed that the dose rate is the most important parameter that can be easily varied in order to optimize the destruction or the protection of the drug

  9. Utilization of male sterility in forage crops

    Energy Technology Data Exchange (ETDEWEB)

    Suginobu, Ken-ichi [National Grassland Research Inst., Nishinasuno, Tochigi (Japan)

    1982-03-01

    The genetic nature of male sterility in forage crops was reviewed. Many workers have suggested that hybrids in forage crops are quite promising. First, the selection of the most desirable parental genotype from a large original population is improtant in heterosis breeding programs. After the more promising inbreds or clones have been selected on the basis of good general combining ability, it is necessary to identify the particular single, three-way or double cross that will produce the highest yields. A high seed yield potential is also important in a new variety so that the seeds can be sold at lower prices than other varieties. A tentative scheme for hybrid seed production by using inbred lines of male sterile or normal parents is proposed. At a breeding station, the seeds for male sterile F/sub 1/(AB), maintainer S/sub 1/(C-S/sub 1/) and either maintainer or restorer S/sub 1/s(D-S/sub 1/, E-S/sub 1/) are produced from the parental clones. At a seed increase agency, the seeds for male sterile F/sub 1/(ABC) and either maintainer or restorer S/sub 2/(D-S/sub 2/) are produced. In the case that D-S/sub 2/ seed production is difficult, maintainer or restorer F/sub 1/(DE) should be produced from D-S/sub 1/ x E-S/sub 1/. These seeds are used for commercial seed production. Seeds of hybrid F/sub 1/(ABCD) or hybrid F/sub 1/(ABCDE) are for practical use.

  10. Thermal In-Pouch Microwave Sterilization

    Science.gov (United States)

    2012-01-09

    straints for heat-sterilized ( retort ) packaging materials. Table 1: Functional Contributions of Materials in Foil Laminations MATERIAL FUNCTIONS...shelf life of the packaged entree items through temperature and humidity changes typically seen throughout the extended shelf life of the items. 15...Barber Industrial Ct.. Villa Rica. GA 30180. Final Scientific Report Light Barrier for Non-Foil Packaging Contract No. W911QY-08-C-0132 Thermal In

  11. Sterile neutrinos in the early universe

    Energy Technology Data Exchange (ETDEWEB)

    Malaney, R.A. (Lawrence Livermore National Lab., CA (USA)); Fuller, G.M. (California Univ., San Diego, La Jolla, CA (USA). Dept. of Physics)

    1990-11-14

    We discuss the role played by right-handed sterile neutrinos in the early universe. We show how well known {sup 4}He constraint on the number of relativistic degrees of freedom at early times limits the equilibration of the right handed neutrino sea with the background plasma. We discuss how this allows interesting constraints to be placed on neutrino properties. In particular, a new limit on the Dirac mass of the neutrino is presented. 12 refs.

  12. Sterilization: new method options, failure rate info.

    Science.gov (United States)

    1998-01-01

    This article discusses new sterilization methods for tubal ligation, failure rates, and risks for ectopic pregnancy in the US. The Filshie clip, which was developed by Femcare, Ltd. in Nottingham, England, and is distributed by Avalon Medical Corp of Vermont, was approved by the US Food and Drug Administration in September 1996. The company has provided training sessions at major universities nationwide and exhibited at national professional association meetings. A training video and two more films will be available in 1998. The new clip is considered a more modern approach to a tubal occlusion method, which relies on newer materials and solves prior problems. Physicians usually used Falope rings, which had better failure rates than the Hulka clip and bipolar coagulation methods. There is a need for more long-term and large scale information exchange about the new Filshie clip. Some physicians still use the Falope ring because it is cost effective and well-studied. Physicians are warned to continue to advise women about the potential failure rates up to 10 years after sterilization and the 1 in 3 risk of ectopic pregnancy. Counseling about failure rates and the risk of ectopic pregnancy should target women under 30 years old, who have the highest failure rates, and women 30-34 years old. All sterilized women should be advised to seek a provider immediately if they have pregnancy symptoms following sterilization. Counseling should include the issue of "regrets," since it is a permanent method. All women should know about nonpermanent methods and experience a basic informed consent process. Young women and newly divorced women are particularly vulnerable to the "regrets" syndrome.

  13. Irradiation sterilization of semi-crystalline polymers

    International Nuclear Information System (INIS)

    Williams, J.; Dunn, T.; Stannett, V.

    1978-01-01

    A semi-crystalline polymer such as polypropylene, is sterilized by high energy irradiation, with the polymer containing a non-crystalline mobilizing additive which increases the free volume of the polymer, to prevent embrittlement of the polymer during and subsequent to the irradiation. The additive has a density of from 0.6 to 1.9 g/cm 3 and a molecular weight from 100 to 10,000 g/mole

  14. Dose mapping for documentation of radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1999-01-01

    The radiation sterilization standards EN 552 and ISO 11137 require that dose mapping in real or simulated product be carried in connection with the process qualification. This paper reviews the recommendations given in the standards and discusses the difficulties and limitations of practical dose...... mapping. The paper further gives recommendations for effective dose mapping including traceable dosimetry, documented procedures for placement of dosimeters, and evaluation of measurement uncertainties. (C) 1999 Elsevier Science Ltd. All rights reserved....

  15. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  16. Sterilization by ionizing radiation comparative evaluation

    International Nuclear Information System (INIS)

    Tata, A.; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 7 on beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems

  17. Counselling women considering or seeking sterilization.

    Science.gov (United States)

    Jackson, T

    1980-12-01

    The view of counseling as assessment and advice-giving places unrealistic and unnecessary stresses on both counselor and client. The counselor-doctor feels responsible for client's subsequent happiness in life and feels guilty if his advice leads to future unhappiness for her. The client feels powerless in the decision-making process and has less incentive to take full responsibility for the direction of her life. A review of studies of emotional adjustment to sterilization revealed a lack of clearly defined goals for preoperative counseling and the failure to test in any way the effect of different models of counseling on client outcome. Issues which might be raised with a woman considering sterilization may be grouped into 4: 1) the woman's life situation; 2) her reasons for considering sterilization; 3) timing; and 4) ambivalence. Counselors should be prepared for and comfortable with the expression of emotion in counseling sessions. Counselors who themselves are unable to cope with expression of intense emotion will send conflicting messages to clients, both giving permission for and disapproving of exploration of certain levels of feeling. The concept of 'regret' as an outcome measure should be refined.

  18. [Essure--a novel method of sterilization].

    Science.gov (United States)

    Revel, Ariel; Nadjary, Michel; Shushan, Asher

    2008-02-01

    Essure hysteroscopic sterilization is a minimally invasive, outpatient approach to female sterilization, which avoids the possible complications of laparoscopic sterilization. This procedure has been available since 2003 in both Europe and North America. We present our experience of the first 12 cases of the procedure performed in Israel. Women who have completed their family planning were offered to consider Essure as their permanent contraception. The procedure was performed without anesthesia by the vaginoscopic technique at the hospital's outpatient clinic. Patients completed a questionnaire and were discharged immediately following the procedure. A follow-up checkup was completed after three months including three dimensional sonography, abdominal X-ray and occasional hysterosalpingogram. Twelve patients participated in the pilot group at Hadassah. The average age was 40 years (34-45) and the average number of children was 5 (4-8). The average time for the procedure was under 8 minutes. Periostial adhesions required adhesiolysis prior to insertion of the device in one patient. All patients resumed their normal activity on the same day. Our patient satisfaction survey revealed that the procedure was associated with high satisfaction levels. Sonographic and radiographic studies confirmed the good placement of the device. The Essure procedure was well tolerated by patients. The limitation is probably going to be the price of Essure, as this procedure is not covered by the 'health basket' in Israel.

  19. Sterilization of health care products - Radiation. Part 2: Establishing the sterilization dose

    International Nuclear Information System (INIS)

    2006-01-01

    This part of ISO 11137 describes methods that may be used to establish the sterilization dose in accordance with one of the two approaches specified in 8.2 of ISO 11137-1:2006. The methods used in these approaches are: a) dose setting to obtain a product-specific dose; b) dose substantiation to verify a preselected dose of 25 kGy or 15 kGy. The basis of the dose setting methods described in this part of ISO 11137 (Methods 1 and 2) owe much to the ideas first propounded by Tallentire (Tallentire, 1973 [17]; Tallentire, Dwyer and Ley, 1971 [18]; Tallentire and Khan, 1978 [19]). Subsequently, standardized protocols were developed (Davis et al., 1981 [8]; Davis, Strawderman and Whitby, 1984 [9]) which formed the basis of the dose setting methods detailed in the AAMI Recommended Practice for Sterilization by Gamma Radiation (AAMI 1984, 1991 [4], [6]). Methods 1 and 2 and the associated sterilization dose audit procedures use data derived from the inactivation of the microbial population in its natural state on product. The methods are based on a probability model for the inactivation of microbial populations. The probability model, as applied to bioburden made up of a mixture of various microbial species, assumes that each such species has its own unique D 10 value. In the model, the probability that an item will possess a surviving microorganism after exposure to a given dose of radiation is defined in terms of the initial number of microorganisms on the item prior to irradiation and the D 10 values of the microorganisms. The methods involve performance of tests of sterility on product items that have received doses of radiation lower than the sterilization dose. The outcome of these tests is used to predict the dose needed to achieve a predetermined sterility assurance level, SAL. Methods 1 and 2 may also be used to substantiate 25 kGy if, on performing a dose setting exercise, the derived sterilization dose for an SAL of 10 -6 is u ≤25 kGy. The basis of the method

  20. Pink bollworm integrated management using sterile insects under field trial conditions, Imperial Valley, California

    International Nuclear Information System (INIS)

    Walters, M.L.; Staten, R.T.; Roberson, R.C.

    2000-01-01

    The pink bollworm moth (Pectinophora gossypiella Saunders) feeds almost exclusively on cotton (Gossypium spp.) and causes economic loss (Pfadt 1978). The pink bollworm (PBW) is often the key pest of cotton in Arizona, southern California, and northwestern Mexico. The larvae (immature stages) bore into the developing cotton fruit, where they feed on the cotton lint and seeds, causing significant damage and dramatically reducing the yield of cotton lint (Pfadt 1978). The PBW is difficult to control with conventional means (insecticides) because it spends the destructive larval phase inside the cotton boll where it is well protected from control measures. Cultural controls, such as a short growing season, have successfully decreased the population in the Imperial Valley (Chu et al. 1992) to the point where eradication may be possible using sterile insects and genetically engineered cotton. Because the PBW is an introduced insect, with few plant hosts other than cultivated cotton, its eradication from continental USA is a desirable and economically attractive alternative to the continued use of pesticides and/or further loss to the pest. Mass releases of sterile insects began in earnest in 1970 in the San Joaquin Valley, California, in order to inhibit normal reproduction and to eradicate the pest in an environmentally responsible manner. Sterile release involves mass production and sexual sterilisation using irradiation (20 krad for PBW adults). This was accomplished by building a rearing facility in Phoenix, AZ. The facility has 6,410 square metres of permanent laboratories, rearing and irradiation chambers and insect packing rooms. The facility operates the year round but with a variable production rate, that is, maximal during the cotton growing season (May through September). Sterile insect technology is based on the monitoring of the native and sterile populations in the field and the subsequent release of appropriate numbers of sterile insects in order to

  1. Risk analysis of sterile production plants: a new and simple, workable approach.

    Science.gov (United States)

    Gapp, Guenther; Holzknecht, Peter

    2011-01-01

    regard to sterility, it is assessed with the prime rating of 1. If the topic is not satisfactory and very weak, the response is 5. Risk numbers from 2 to 4 are for intermediate situations. Because each unit of the production process could have a different type of impact of varying severity on the total product sterility, the average of the answers regarding the unit (e.g., 1, 2) is multiplied by the risk emphasis factor, which could be 1, 3, or 5. To make the rating even more distinct, colors are assigned from green (very good) through orange to red (very weak). There are currently three different risk analyses available for three different production processes. The results provide the users, that is, production personnel and quality assurance personnel, valuable feedback about the risk for possible non-sterility in their process as well as sound arguments to present to management defending upgrades of their production line and control systems in the case of high numbers and red colors. Three years of implementation have demonstrated that this new risk analysis approach works and is very useful in identifying potentially risky components of a production process, thus preventing in advance the production of non-sterile product batches for the market, and finally protecting the patient from hazardous products.

  2. Sensitivity of viruses to radiation sterilization

    International Nuclear Information System (INIS)

    Dziedzic Goclawska; A

    1999-01-01

    The hazard of infectious disease transmission with tissue allografts is a major concern in tissue banking practice. Microorganisms can be introduced into grafts during tissue collection, processing and storage, but even when all these procedures are performed under a septic conditions, the possibility of fungal, bacterial or viral disease transmission of donor origin can not be excluded. Therefore, in order to minimize the risk of infectious disease transmission, several steps should be undertaken, including a careful donor screening, proper tissue processing and sterilization of tissue allografts. The risk of transmission of viral infections such as hepatitis B, C, other viruses and particularly HIV with tissue allografts is of great significance and the search for sterilizing methods which inactivate and/or highly reduce viral infectivity continues. Sterilization of tissue allografts with ionizing radiation (introduced in the mid of 1950s) is increasingly used in tissue banking practice. The effectiveness of the radiation-sterilization procedure depends on the amount of energy transferred, the number of contaminating microorganisms and their resistance to ionizing radiation (initial contamination, bioburden). Usually, spores are more resistant than vegetative forms of bacteria, some fungi may be as resistant as bacterial spores, and viruses are, in general, more resistant than bacteria. Dita concerning effectiveness of ionizing radiation to inactivate viruses (e.g. such as HBV, HCV or HIV) in tissue allografts collected from cadavers are scarce. It has been found that the dose of irradiation needed to reduce HIV load by I log10 unit (D10) is about 4.0 kGy or even 5.6 kGy. The level of infectious HIV in plasma is usually evaluated by titration of tissue culture infective dose (TCID50/ml). Taking into consideration the recommended sterility assurance level (SAL) 10-6, assuming the HIV bioburden to be 103 TCID50/ml for the state of acute infection and D10 value of 4

  3. Pre-sterilization contamination of disposable medical products and the choice of minimum sterilization dose

    International Nuclear Information System (INIS)

    Horakova, V.; Buriankova, E.

    1975-01-01

    The bacterial contamination was assessed on randomly taken samples of blood-transfusion devices, donor sets, intra-uterine contraceptive devices and inserters, surgical gloves and dressing material prior to sterilization. The quantitative and qualitative efficiency of six nutrient media was compared. The best results were obtained with the enriched ''Universal'' medium. It was confirmed that the contamination of plastic products was low compared with dressing material. Most frequently, Gram-positive aerobic spore-forming rods and Gram-positive cocci were found on non-sterile medical disposable products. A method was tested to obtain a general informative picture of the resistance of bacteria on products. The methods used for choosing the dose for radiation sterilization of medical products are discussed. (author)

  4. Evaluation of steam sterilization conditions for [18F]fludeoxyglucose

    International Nuclear Information System (INIS)

    Santos, Priscilla F.; Nascimento, Leonardo T.; Valente, Eduardo S.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z.

    2011-01-01

    [ 18 F]Flu deoxyglucose ( 18 FDG) is the most commonly used radiopharmaceutical for positron emission tomography. Sterile filtration of the final product into sterile vials using 0.22 μm filter membrane is usually adopted for 18 FDG. However, Good Manufacturing Practice (GMP) guidelines recommend heat sterilization as the method of choice to ensure sterility of pharmaceutical preparations. The aim of this study was to essay different steam sterilization conditions in order to choose the best one for 18 FDG. Three different sterilization conditions were essayed. The first one at 121 deg C for 15 minutes, the second one at 135 deg C for 3.5 minutes and the third one at 133 deg C for 2 minutes. 18 FDG pH-formulation was kept around 6.0. At the end of autoclave cycles, 18 FDG sterility was evaluated by direct inoculation of 18 FDG in culture media and radiochemical purity was determined by TLC and HPLC. Results demonstrated that all essayed conditions were able to ensure 18 FDG sterility, but caused a decrease in radiochemical purity of 18 FDG. Autoclave cycle at 133 deg C for 2 minutes was the best essayed condition for 18 FDG terminal sterilization, once it provided the greater radiochemical purity value and took less time. 18 FDG was able to meet specifications after autoclave cycles, what supports the application of steam sterilization in routine 18 FDG production, in compliance with GMP. (author)

  5. Degradation of chitosan-based materials after different sterilization treatments

    International Nuclear Information System (INIS)

    San Juan, A; Montembault, A; Royaud, I; David, L; Gillet, D; Say, J P; Rouif, S; Bouet, T

    2012-01-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  6. Use of sterile insect technique in Brazil by the sterilization of Ceratitis capitata (Wied., 1824)

    International Nuclear Information System (INIS)

    Okeese, G.O.; Kitomer, T.J.; Gayaradus, L.B.; Etrigan, M.; Jansen, C.W.J.H.; Houlahar, H.L.

    2006-01-01

    The Sterile Insect Technique is a method of pest control allowed in Integrated Pest Management programs in fruit growing, where sterile insects released compete in mate process against fertile wild ones, generating a gradative population reduction. The most used sterilization method is using ionizing radiation from 60 Co or 137 Cs. For efficient application of SIT, an important item is the sterilizing dose. This must be as lower as possible in order to preserve insect behavior. In this work, it was studied the reproductive potential of fruit fly Ceratitis capitata, tsl VIENNA 8 strain, irradiated with different doses of gamma radiation. This strain has been used in population suppression programs at fruit-growing areas from Northeast of Brazil, through a partnership between CENA and Bio factory MOSCAMED Brazil, intending only sterile male releases. Radiation source used was a 60 Co irradiator, with 17.2 x 1012 Bq. Individualized couples were distributed in a randomized delineament with 10 replicates for each treatment and eggs were collected for fifteen days. With 9 and 10 days old, pupae were irradiated with doses ranging from 30 to 120 Gy. All averages of emerged adult's percentages were higher than 90%. In regards to fecundity, different doses did not affect the number of eggs laid, being the overall mean around 30 eggs/couple/day. Fertility data showed that as radiation dose increases, sterility increases. It was concluded that the dose of 90 Gy can be used in Brazil, since to SIT programs a dose is chosen witch prevents an egg hatch higher than 1%. (author)

  7. Sterilization Resistance of Bacterial Spores Explained with Water Chemistry.

    Science.gov (United States)

    Friedline, Anthony W; Zachariah, Malcolm M; Middaugh, Amy N; Garimella, Ravindranath; Vaishampayan, Parag A; Rice, Charles V

    2015-11-05

    Bacterial spores can survive for long periods without nutrients and in harsh environmental conditions. This survival is influenced by the structure of the spore, the presence of protective compounds, and water retention. These compounds, and the physical state of water in particular, allow some species of bacterial spores to survive sterilization schemes with hydrogen peroxide and UV light. The chemical nature of the spore core and its water has been a subject of some contention and the chemical environment of the water impacts resistance paradigms. Either the spore has a glassy core, where water is immobilized along with other core components, or the core is gel-like with mobile water diffusion. These properties affect the movement of peroxide and radical species, and hence resistance. Deuterium solid-state NMR experiments are useful for examining the nature of the water inside the spore. Previous work in our lab with spores of Bacillus subtilis indicate that, for spores, the core water is in a more immobilized state than expected for the gel-like core theory, suggesting a glassy core environment. Here, we report deuterium solid-state NMR observations of the water within UV- and peroxide-resistant spores from Bacillus pumilus SAFR-032. Variable-temperature NMR experiments indicate no change in the line shape after heating to 50 °C, but an overall decrease in signal after heating to 100 °C. These results show glass-like core dynamics within B. pumilus SAFR-032 that may be the potential source of its known UV-resistance properties. The observed NMR traits can be attributed to the presence of an exosporium containing additional labile deuterons that can aid in the deactivation of sterilizing agents.

  8. Is parotid saliva sterile on entry to the oral cavity?

    DEFF Research Database (Denmark)

    Schrøder, Stine A; Bardow, Allan; Eickhardt-Dalbøge, Steffen

    2017-01-01

    CONCLUSION: The present study indicates that parotid saliva is sterile on entry to the oral cavity. OBJECTIVES: The objective was to investigate if parotid saliva is sterile on entry to the oral cavity and, thus, prior to contamination by oral bacteria. METHOD: Forty healthy volunteers were...... included in sterile parotid saliva collection. Parotid saliva was collected using a sterile Lashley cup, placed over the papilla of the Stensen´s duct, as well as sterile tubes and syringes for collection. All collections were followed by collection of a positive control sample where some of the sterile...... obtained parotid saliva had been exposed to the contralateral mucosal membranes. All samples parotid saliva, as well as the positive controls, were cultivated, and 10 randomly selected parotid saliva samples underwent polymerase chain reaction (PCR) analyses. RESULTS: In 33 of 40 parotid saliva samples...

  9. Studies on induced mutation of sesame male sterility

    International Nuclear Information System (INIS)

    Li Yingde; Feng Xiangyun; Zhao Yingzhong

    2001-01-01

    The dry seeds of the high yielding cultivar, Yuzhi-4, were irradiated with 300, 500 and 700 Gy of 60 Co- gamma rays. 3277 M 1 plants were harvested separately as single plants and also in bulk, by doses. In M 2 , the single plant seeds were grown in progeny rows and the bulked seeds were grown as bulks. 25 male sterile plants were screened from M 2 . 10 of the 25 male sterile plants were from the progenies of the single plant seeds and 15 were from the progenies of the bulked seeds. In further genetic research of the 25 male sterile plants in M 3 and M 4 , 6 separate genic male sterile (GMS) lines were identified. Their male sterility was stable and was controlled by a pair of alleles, male fertility being dominant to sterility. (author)

  10. Radiation sterilization of some pharmaceutical preparations and medical products

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Makhkamov, Sh.M.; Urinov, Sh.S.; Turaev, A.S.; Sultanov, M.S.; Inagomov, Kh.S.

    2006-01-01

    Full text: In connection with intensive development of pharmacology and medical techniques, use of the products contacting to blood, with the internal environment of an organism, with wound surface, with mucous membranes and skin there were high requirements to sterility of pharmaceutical preparations and medical products. Traditional methods of sterilization (heat treatment, gas processing and processing the ferry) have some restrictions in application, and not insufficient degree of sterilization required for pharmaceutical preparations and medical products. Thermal processing can lead to degradation of structure (medicine), mechanical changes and loss of medical properties. Besides, it is impossible to carry out sterilization of many pharmaceutical preparations by a method of heat treatment. Sterilization of products in packing is very complicated, because sterilization temperature of packing and a product is different. Gas processing is basically applied to sterilization of medical products (syringes, bandage, cotton wools, etc.). However, the degree of sterility is low, because of rather low ability and heterogeneity of sterilizing substance. Sterilization in packing represents special difficulty and demands additional charges related with delivery of the purified gas from abroad. Last years alongside with known technological methods of sterilization of medical products and pharmaceutical preparations radiating methods of processing have found wide application. Use of electronic bunches with the moderate energy and various isotopes became a basis for formation and development of a new direction in the medicine, called by 'radiation sterilization'. The radiation technology is highly harmless and economic, not polluting substance and surrounding space. Unlike the specified traditional methods, radiating processing of products by the isotope 60 Co, radiating the gamma quantum, has unique opportunities - high penetrability in substance, providing uniformity of

  11. A see-saw mechanism with light sterile neutrinos

    International Nuclear Information System (INIS)

    McKellar, B.H.J.; Garbutt, M.; Stephenson, G.J.; Goldman, T.

    2001-01-01

    The usual see-saw mechanism for the generation of light neutrino masses is based on the assumption that all of the flavours of right-handed (more properly, sterile) neutrinos are heavy. If the sterile Majorana mass matrix is singular, one or more of the sterile neutrinos will have zero mass before mixing with the active (left-handed) neutrinos and be light after that mixing is introduced In particular, a rank 1 sterile mass matrix leads naturally to two pseudo-Dirac pairs, one very light active Majorana neutrino and one heavy sterile Majorana neutrino. For any pattern of Dirac masses, there exists a region of parameter space in which the two pseudo-Dirac pairs are nearly degenerate in mass. This, in turn, leads to large amplitude mixing of active states as well as mixing into sterile states

  12. Male sterility in plants. Induction, isolation and utilization

    International Nuclear Information System (INIS)

    Driscoll, C.J.; Barlow, K.K.

    1976-01-01

    Both induced and spontaneously arising male sterility mutants exist in a number of important plant species. These mutants are somewhat unique in that they effect procedures for breeding improved varieties. They allow for the possibility of easily obtaining large numbers of hybrids, population breeding systems and the production of hybrid varieties. These mutants are normally classified as cytoplasmic mutants or chromosomal mutants, the latter also being referred to as nuclear or genic mutants. Specific examples of these types of sterility are examined in relation to the breeding system of the species and their potential use for varietal development. Male sterility in diploid and polyploid species is compared, with reference to gene duplication in polyploids. The mechanism of male sterility is examined in the various species at the anatomical and biochemical levels. Methods of isolating male sterility mutants are compared and a specific example is outlined for hexaploid wheat. Future use of male sterility mutants for improving varieties of various crops is examined. (author)

  13. Mars Technology Program: Planetary Protection Technology Development

    Science.gov (United States)

    Lin, Ying

    2006-01-01

    This slide presentation reviews the development of Planetary Protection Technology in the Mars Technology Program. The goal of the program is to develop technologies that will enable NASA to build, launch, and operate a mission that has subsystems with different Planetary Protection (PP) classifications, specifically for operating a Category IVb-equivalent subsystem from a Category IVa platform. The IVa category of planetary protection requires bioburden reduction (i.e., no sterilization is required) The IVb category in addition to IVa requirements: (i.e., terminal sterilization of spacecraft is required). The differences between the categories are further reviewed.

  14. Plant's sterilization rule for fertile women cited.

    Science.gov (United States)

    1979-01-01

    The American Cyanamid Corporation has been cited by the Occupational Safety and Health Administration (OSHA) for violating federal law by requiring female employees of childbearing age to be sterilized in order to continue working in areas of the plant where they would be exposed to high levels of airborne lead. High levels of airborne lead can cause damage to workers' reproductive systems and be responsible for birth defects in fetuses. The OSHA charged that American Cyanamid's policy constituted a "willful violation" of the 1970 Occupational Safety and Health Act. The Act requires employers to provide employment that is free from recognized hazards likely to cause death or physical harm. According to OSHA, the Act does not allow an employer to eliminate the hazard by compelling employees to choose between losing their jobs and undergoing sterilization. The reproductive health of workers is considered a valid part of OSHA's regulatory concern. The citation, which carries a $10,000 fine, grew out of a complaint that was filed by the Oil, Chemical and Atomic Workers Union on behalf of 5 female workers working in the lead pigment division of the company's Willow Island, West Virginia plant. The 5 employees alleged that they had themselves sterilized to avoid being transferred to other and possibly lower paying janitorial jobs or losing thier jobs completely. The company is appealing the citation. The union has also filed a complaint with the Equal Employment Opportunity Commission charging American Cyanamid with sex discrimination, since only the women workers are at risk of being transferred to lower paying jobs.

  15. A standardized and safe method of sterile field maintenance during intra-operative horizontal plane fluoroscopy

    Directory of Open Access Journals (Sweden)

    Kaska Serge C

    2010-12-01

    Full Text Available Abstract Background Intra-operative fluoroscopy for orthopaedic procedures frequently involves imaging in the horizontal plane, which requires the lower portion of the C-arm (x-ray tube to be rotated from an unsterile zone (beneath the table into the sterile field. To protect the integrity of the sterile field the C-arm must be draped repeatedly throughout the surgical case. The current, un-standardized, practice employs draping procedures which violate the Association of peri-Operative Registered Nurses (AORN Standards and Recommended Practices, waste time and material, and pose an increased risk for surgical site infection. Presentation of the hypothesis Use of a novel sterile C-arm drape (C-armor that maintains the integrity of the sterile field, will improve operating room efficiency and reduce surgical site infection risk factors. This reduction in risk factors may potentially reduce surgical site infections in orthopaedic surgical cases requiring repeated horizontal x-ray imaging. Testing the Hypothesis Savings in time and material and the reduction in surgical site infection risk factors afforded by using C-armor are intuitive to those skilled in the practice of orthopaedic surgery. Testing for a reduction in the number of microorganisms introduced to the surgical site by improved C-arm draping would be challenging due to the multiple confounding factors during a surgical operation. Determination of an absolute reduction in surgical site infections may be possible, but will require accounting for many confounding variables and a large study sample in order to achieve statistical significance. Implications of the Hypothesis Improved intraoperative workflow, healthcare savings and a reduction in surgical site infection risk factors will be achieved by utilizing a standardized and safe method of sterile field maintenance during intra-operative horizontal plane fluoroscopy.

  16. Gene, protein, and network of male sterility in rice

    OpenAIRE

    Wang, Kun; Peng, Xiaojue; Ji, Yanxiao; Yang, Pingfang; Zhu, Yingguo; Li, Shaoqing

    2013-01-01

    Rice is one of the most important model crop plants whose heterosis has been well-exploited in commercial hybrid seed production via a variety of types of male-sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and prot...

  17. Cross-cultural attitudes toward voluntary sterilization.

    Science.gov (United States)

    Hong, S

    1985-06-01

    The degree to which voluntary sterilization (VS) is accepted as a form of fertility control throughout the world was assessed by examining the prevalence and legal status of VS in all countries for which information was available and by examining current religious and traditional attitudes toward VS. Information on VS prevalence for 73 countries indicates that in 28 countries, 10% of all eligible couples rely on VS. In a number of countries, including Korea, New Zealand, Panama, US, and Puerto Rico, 25% or more of all currently married women of reproductive age rely on VS. VS prevalence rates tend to be higher in Asian countries than in African, Latin American, and Middle Eastern countries. In a number of countries, the average age and family size of VS acceptors is declining. Information on the legal status of VS for 124 countries indicates that 22 countries have laws which permit or encourage VS. These countries contain 13.4% of the world's population. In 54 countries, representing 60% of the world's population, there are no laws restricting VS, and VS is generally assumed to be legal. In 29 countries, representing 14% of world's population, the legal status of VS is unclear. In the remaining 29 countries, sterilization is forbidden except for medical or eugenic reasons. The degree to which these laws actually restrict VS varies from country to country. For example in Indonesia VS is illegal but widely practiced. Although some religious teachings discourage sterilization, the impact of religion on VS varies considerably from country to country. In the Catholic countries of Panama, Dominican Republic, and Philippines the prevalence of VS is high, and in the Catholic countries of Argentina, Bolivia, and Uruguay the prevalence of VS is low. VS prevalence is generally low in Muslim countries, but high in the Muslim countries of Tunisia, Indonesia, and Bangladesh. VS prevalence is high in the Buddhist country of Thailand but low in the Buddhist country of Burma

  18. Search for sterile neutrinos at RENO

    Science.gov (United States)

    Yeo, In Sung; RENO Collaboration

    2017-09-01

    The RENO experiment was designed to measure a neutrino mixing angle, θ13, by detecting electron antineutrinos emitted from the Hanbit nuclear reactors in Korea, and succeeded to measure θ13 from the disappearance mode in three neutrino frame. We investigate the possibility of sterile neutrinos existence at RENO experiment and compare data with Monte Carlo generated in four neutrino frame. In this talk, we present some recent results using chi-square analysis method. The probability deficit curve as a function of an effective baseline and the excluded contour plot in sin2(2 θ14) - Δ(m41)2 space will be shown.

  19. Processing laboratory of radio sterilized biological tissues

    International Nuclear Information System (INIS)

    Aguirre H, Paulina; Zarate S, Herman; Silva R, Samy; Hitschfeld, Mario

    2005-01-01

    The nuclear development applications have also reached those areas related to health. The risk of getting contagious illnesses through applying biological tissues has been one of the paramount worries to be solved since infectious illnesses might be provoked by virus, fungis or bacterias coming from donors or whether they have been introduced by means of intermediate stages before the use of these tissues. Therefore it has been concluded that the tissue allografts must be sterilized. The sterilization of medical products has been one of the main applications of the ionizing radiations and that it is why the International Organization of Atomic Energy began in the 70s promoting works related to the biological tissue sterilization and pharmaceutical products. The development of different tissue preservation methods has made possible the creation of tissue banks in different countries, to deal with long-term preservation. In our country, a project was launched in 1998, 'Establishment of a Tissue Bank in Latino america', this project was supported by the OIEA through the project INT/ 6/ 049, and was the starting of the actual Processing Laboratory of Radioesterilized Biological Tissues (LPTR), leaded by the Chilean Nuclear Energy Commission (CCHEN). This first organization is part of a number of entities compounding the Tissue Bank in Chile, organizations such as the Transplantation Promotion Corporation hospitals and the LPTR. The working system is carried out by means of the interaction between the hospitals and the laboratory. The medical professionals perform the procuring of tissues in the hospitals, then send them to the LPTR where they are processed and sterilized with ionizing radiation. The cycle ends up with the tissues return released to the hospitals, where they are used, and then the result information is sent to the LPTR as a form of feedback. Up to now, human skin has been processed (64 donors), amniotic membranes (35 donors) and pig skin (175 portions

  20. Basic radiation sterilization properties of packaging materials

    International Nuclear Information System (INIS)

    Zouharova, A.; Kolarova, J.; Olbrichova, D.

    1984-01-01

    The foils of various materials were irradiated with 60 Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.)

  1. Environment and the sterile insect technique

    International Nuclear Information System (INIS)

    Nagel, P.; Peveling, R.

    2005-01-01

    The sterile insect technique (SIT) is an exceptionally promising pest control method in terms of efficacy and environmental compatibility. Assessments of environmental risks vary according to the status and origin of the target pests. The suppression or eradication of exotic pest populations with the SIT raises few environmental concerns, and these are related mainly to pre-release suppression techniques. However, the elimination of native species, or at least populations of native species, requires more detailed and complex assessments of ecological effects and consequences for biodiversity conservation. Eradication programmes provide opportunities to study these topics within the scope of both environmental impact assessments and operational monitoring programmes. (author)

  2. Proton decay and light sterile neutrinos

    Science.gov (United States)

    Helo, Juan C.; Hirsch, Martin; Ota, Toshihiko

    2018-06-01

    Within the standard model, non-renormalizable operators at dimension six ( d = 6) violate baryon and lepton number by one unit and thus lead to proton decay. Here, we point out that the proton decay mode with a charged pion and missing energy can be a characteristic signature of d = 6 operators containing a light sterile neutrino, if it is not accompanied by the standard π0 e + final state. We discuss this effect first at the level of effective operators and then provide a concrete model with new physics at the TeV scale, in which the lightness of the active neutrinos and the stability of the proton are related.

  3. Sterile searches with Liquid Argon at FNAL

    CERN Document Server

    Raselli, Gian Luca

    2017-01-01

    A new Short Baseline Neutrino (SBN) experiment is in preparation at FNAL to definitely prove or exclude the existence of non-standard neutrino oscillations into sterile states. The program foresees the deployment along the Booster Neutrino Beam (BNB) of three detectors, all based on the liquid-argon time projection chamber technique. This technology has been taken to full maturity with ICARUS T600, which will act as far detector after the completion of the overhauling at CERN and its transportation to FNAL. The program foresees the data taking for three years.

  4. Surgical sterilization of free-ranging wolves.

    OpenAIRE

    Spence, C E; Kenyon, J E; Smith, D R; Hayes, R D; Baer, A M

    1999-01-01

    The objective of the study was to determine whether surgical sterilization of both males and females in wolf pairs alters basic wolf social and territorial behaviors. Wolves were located from the air by snow-tracking methods and were tranquilizer-darted from a helicopter. Surgeries were performed either in a tent at the capture site or in a heated building in a nearby village. Six vasectomies and seven uterine horn ligations were performed in January and February of 1996 and 1997. Two females...

  5. Electron sterilization validation techniques using the controlled depth of sterilization process

    International Nuclear Information System (INIS)

    Cleghorn, D.A.; Nablo, S.V.

    1990-01-01

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and X-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating X-ray dose ratios are possible for the application of the technique. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed. (author)

  6. American Sterilization: The Racist Justifications for Sterilization in the United States

    OpenAIRE

    Trevor Price

    2016-01-01

    An investigative analysis into anthropometrics, sterilization, eugenics, and other forms of scientific racism used to justify white supremacy and racial thought in the 19th and 20th centuries in the United States. The Tuskegee syphilis study, Darwinistic ideals, and neo-Lamarckian thoughts are critically analyzed as justifications for institutional racism.

  7. International standard (ISO) of radiation sterilization and issues in the sterilization dose setting

    International Nuclear Information System (INIS)

    Takehisa, Masaaki

    1995-01-01

    The ISO dose setting method 1 uses bioburden and verification by sublethal sterility test. Current devices produced in clean environmental have low bioburden, however, sensitivity of verification test declines at low bioburden. Validation of verification in this region should be further studied. A dose setting using D 10 of bioburden isolates should be reevaluated and included in the ISO. (author)

  8. Dark matter relic abundance and light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi-Lei [Center for High Energy Physics,Peking University, Beijing 100871 (China); Zhu, Shou-hua [Center for High Energy Physics,Peking University, Beijing 100871 (China); Institute of Theoretical Physics & State Key Laboratory of Nuclear Physics and Technology,Peking University, Beijing 100871 (China); Collaborative Innovation Center of Quantum Matter,Beijing 100871 (China)

    2017-01-09

    In this paper, we calculate the relic abundance of the dark matter particles when they can annihilate into sterile neutrinos with the mass ≲100 GeV in a simple model. Unlike the usual standard calculations, the sterile neutrino may fall out of the thermal equilibrium with the thermal bath before the dark matter freezes out. In such a case, if the Yukawa coupling y{sub N} between the Higgs and the sterile neutrino is small, this process gives rise to a larger Ω{sub DM}h{sup 2} so we need a larger coupling between the dark matter and the sterile neutrino for a correct relic abundance.

  9. Exploiting novel sterilization techniques for porous polyurethane scaffolds.

    Science.gov (United States)

    Bertoldi, Serena; Farè, Silvia; Haugen, Håvard Jostein; Tanzi, Maria Cristina

    2015-05-01

    Porous polyurethane (PU) structures raise increasing interest as scaffolds in tissue engineering applications. Understanding the effects of sterilization on their properties is mandatory to assess their potential use in the clinical practice. The aim of this work is the evaluation of the effects of two innovative sterilization techniques (i.e. plasma, Sterrad(®) system, and ozone) on the morphological, chemico-physical and mechanical properties of a PU foam synthesized by gas foaming, using water as expanding agent. In addition, possible toxic effects of the sterilization were evaluated by in vitro cytotoxicity tests. Plasma sterilization did not affect the morphological and mechanical properties of the PU foam, but caused at some extent degradative phenomena, as detected by infrared spectroscopy. Ozone sterilization had a major effect on foam morphology, causing the formation of new small pores, and stronger degradation and oxidation on the structure of the material. These modifications affected the mechanical properties of the sterilized PU foam too. Even though, no cytotoxic effects were observed after both plasma and ozone sterilization, as confirmed by the good values of cell viability assessed by Alamar Blue assay. The results here obtained can help in understanding the effects of sterilization procedures on porous polymeric scaffolds, and how the scaffold morphology, in particular porosity, can influence the effects of sterilization, and viceversa.

  10. Induction of male sterility in rice using chemical mutagens

    Energy Technology Data Exchange (ETDEWEB)

    Minocha, J L; Gupta, R K [Department of Genetics, Punjab Agricultural University, Ludhiana (India)

    1988-07-01

    Full text: To diversify the sources of cytoplasmic male sterility for hybrid seed production in rice (Oryza sativa L.) attempts were made to induce this character in a popular indica cultivar PR 106 through chemical mutagens. Seeds were treated with 0.4% ethidium bromide (EB) for 24 or 48h at 10 deg. C, with 0.4% ethyl methanesulphonate (EMS) for 24 or 48h at 10 deg. C for 16 hr at 20 deg. C or with 0.2% streptomycin sulphate (SM) for 24 or 48 hr at 10 deg. C. In M{sub 2} male sterile plants were detected in eleven different progenies, one from SM treatment and the remaining from EMS treatments. All the sterile plants had 100% non-stainable aborted pollen. Seed set upon open-pollination of the male sterile plants with the variety PR 106 ranged from 0.03 to 4.93 per cent whereas no seed formed in bagged panicles. In M{sub 3}, open-pollinated progenies of the male sterile plants and their fertile sibs were further studied. Two progenies segregated for male sterility, all others had only fertile plants. In one of the segregating progenies, five out of six and in the other nine out of fourteen plants were male sterile. The progenies of fertile sibs did not have any male sterile plant. The results indicate that sterility of cytoplasmic type has been induced by EMS. The parental variety PR 106 acts as the maintainer. (author)

  11. Genetic expression of induced rice sterility under alien-cytoplasm

    International Nuclear Information System (INIS)

    Wang Naiyuan; Cai Zhijun; Liang Kangjing; Li Yu

    2005-01-01

    Rice restorer lines were treated with 60 Co γ-ray and 4 male sterile mutants obtained with the fertility of controlled by 4 non-allelic recessive genes, respectively. Sixty combinations were made by using male sterile plants/fertile plants as male parents, and 15 different cytoplasmic substitution lines of the same cell nucleus as female parents. The result showed that F 1 spikelets were normal and fertile, and different numbers of male sterile plants were segregated in F 2 . Complete fertility genotype was not found among interactions between induced male sterile genes and alien-cytoplasms. (authors)

  12. Protozoa and their bacterial prey colonize sterile soil fast

    DEFF Research Database (Denmark)

    Altenburger, Andreas; Ekelund, Flemming; Jacobsen, Carsten Suhr

    2010-01-01

    We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them to the at......We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them...

  13. Gene, protein and network of male sterility in rice

    Directory of Open Access Journals (Sweden)

    Wang eKun

    2013-04-01

    Full Text Available Rice is one of the most important model crop plants whose heterosis has been well exploited in commercial hybrid seed production via a variety of types of male sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and proteins related to cytoplasmic male sterility, photoperiod sensitive male sterility, self-incompatibility and other types of microspores deterioration have been characterized through genetics or proteomics. Especially the latter, offers us a powerful and high throughput approach to discern the novel proteins involving in male-sterile pathways which may help us to breed artificial male-sterile system. This represents an alternative tool to meet the critical challenge of further development of hybrid rice. In this paper, we reviewed the recent developments in our understanding of male sterility in rice hybrid production across gene, protein and integrated network levels, and also, present a perspective on the engineering of male sterile lines for hybrid rice production.

  14. End-preparation assessments and tests for compounded sterile preparations.

    Science.gov (United States)

    McElhiney, Linda F

    2013-01-01

    Outsourcing has become a necessity to obtain sterile products that are currently on backorder. Because of the expense of outsourcing sterile compounding, pharmacy leadership in health systems are now considering the option of insourcing and batch preparing compounded sterile preparations, which can be a viable option for a health system. It can significantly decrease drug-spending costs, and the pharmacy has a complete record of the compounding process. The key to preparing high-quality, safe, sterile preparations and meeting United States Pharmacopeia standards is end-preparation assessments and tests.

  15. Sterilization of the artificial blood circulation apparatus with ozone

    Energy Technology Data Exchange (ETDEWEB)

    Pisarevskii, A A; Korukhov, N I.U.; Brazhnikov, E M; Konstantinova, M L; Razumovskii, S D

    1982-01-01

    Presented in this paper is the sterilization method of the assisted circulation unit. The method has been approved by stand testing and then applied for sterilizing the unit Ae, yeK-5 m when experimental implanting artificial heart. According to the method, ozone in concentration of 5 x 10(-3) moles/1 and with flow rate of 0,5 1/min is passed through an internal circuit of the unit during I h and 15 min. Control wash-out samples from lines have demonstrated complete sterility of the internal circuit. The method makes the sterilization process of such units much easier and may be recommended for clinical application.

  16. Induction of male sterility in rice using chemical mutagens

    International Nuclear Information System (INIS)

    Minocha, J.L.; Gupta, R.K.

    1988-01-01

    Full text: To diversify the sources of cytoplasmic male sterility for hybrid seed production in rice (Oryza sativa L.) attempts were made to induce this character in a popular indica cultivar PR 106 through chemical mutagens. Seeds were treated with 0.4% ethidium bromide (EB) for 24 or 48h at 10 deg. C, with 0.4% ethyl methanesulphonate (EMS) for 24 or 48h at 10 deg. C for 16 hr at 20 deg. C or with 0.2% streptomycin sulphate (SM) for 24 or 48 hr at 10 deg. C. In M 2 male sterile plants were detected in eleven different progenies, one from SM treatment and the remaining from EMS treatments. All the sterile plants had 100% non-stainable aborted pollen. Seed set upon open-pollination of the male sterile plants with the variety PR 106 ranged from 0.03 to 4.93 per cent whereas no seed formed in bagged panicles. In M 3 , open-pollinated progenies of the male sterile plants and their fertile sibs were further studied. Two progenies segregated for male sterility, all others had only fertile plants. In one of the segregating progenies, five out of six and in the other nine out of fourteen plants were male sterile. The progenies of fertile sibs did not have any male sterile plant. The results indicate that sterility of cytoplasmic type has been induced by EMS. The parental variety PR 106 acts as the maintainer. (author)

  17. Comparative mating and reproductive performance of radiation sterilized and radiation induced F1 sterile males of Earias vittella (Fabricius)

    International Nuclear Information System (INIS)

    Shantharam, K.; Tamhankar, A.J.; Harwalkar, M.R.

    1995-01-01

    Studies were conducted on mating behaviour and reproductive performance of a) Earias vittella (F.) males rendered sterile by exposing them to 300 Gy gamma rays and b) F 1 sterile males obtained by exposing parent male to 100 Gy gamma rays. For the study, males were allowed only one mating with a normal female. Results revealed that premating period, period in copula and per cent insects mating were not adversely affected in case of both types of sterile males and fecundity also remained unaffected. However, in both types of sterile males, incidence of spermatophore transfer without sperm was very large and such an occurrence (including reduced spermatophore transfer) was significantly higher in case of radiation sterilized males compared to the F 1 sterile males. Inability to produce and transfer spermatophore and/or sperm appeared to be a major cause behind the reduced mating competitiveness of both types of males. (author). 22 refs., 2 tabs

  18. Why are rates of sterilization in decline? A pilot study designed to explore reasons for declining female sterilization in Scotland.

    Science.gov (United States)

    Chen, Zhong E; Glasier, Anna; Warner, Pamela

    2008-10-01

    In the last decade, female sterilization had been in decline throughout the UK. It is not clear whether fewer women are requesting sterilization or whether the universal enthusiasm for long-acting reversible methods is leading health professionals to discourage women from being sterilized. Since correct and consistent use of alternative, reversible contraceptive methods depends somewhat on their acceptability, it is important to determine whether women are being refused sterilization or whether they are freely choosing other methods. This study aims to explore whether female sterilization is being widely considered as a contraceptive method, the reasons for choosing or rejecting it, and whether women are being discouraged by health professionals from being sterilized. A self-completed questionnaire survey among 205 women aged 30 to 50 years who felt that their family was complete attending a family planning clinic in Scotland. Of the 203 women included in the study, 151 (74.4%) had heard of female sterilization, 90 had discussed it with someone (60%) and 87 (58%) had considered it as a contraceptive option. Of the 56 women who consulted their family doctor about sterilization, almost half (27; 48%) were not referred to a hospital and fewer than one (17, 30.4%) in three of them was eventually sterilized or had arrangements in place to get it done. Free-text comments from the women revealed a variety of reasons for not choosing female sterilization and suggested that some women are being deterred from sterilization. The study suggests that some women are being actively encouraged by health professionals to use long-acting reversible contraceptive methods and discouraged from choosing sterilization. However, other women recognize for themselves the wisdom of keeping their fertility options open.

  19. When Eggs Don't Hatch. The Benefits of the Sterile Insect Technique

    International Nuclear Information System (INIS)

    Kilian, Lizette

    2012-01-01

    Insect pests, such as the medfly, tsetse flies and carob moth can devastate crops and infect herds, causing severe economic hardship. To suppress the insect pest population and protect their livestock and crops, farmers usually use large quantities of pesticides. However, these pesticides are expensive, a risk to public health and cause environmental damage. Another technique, however, can reduce the insect pest population using natural means that do not require toxic chemicals: the sterile insect technique, or SIT. When female insect pests mate with male partners that have been radiation sterilized, the insemination produces eggs that cannot hatch. Since mating does not produce offspring, the insect population decreases naturally. The pest population can be suppressed with little or no use of pesticides. With the help of the IAEA, farmers have applied SIT successfully in over 20 countries on five continents, for over 15 insect species worldwide.

  20. Sterilization of biological tissues with ionizing radiation

    International Nuclear Information System (INIS)

    Reyes F, M.L.; Martinez P, M.E.; Luna Z, D.

    1997-01-01

    On June 1994, the National Institute of Nuclear Research (ININ) and the South Central Hospital for High Specialty of PEMEX (HCSAE) began a joint work with the finality to obtain radio sterilized amniotic membranes for to be used as cover (biological bandage) in burnt patients. Subsequently the Chemistry Faculty of UNAM and the National Institute of Cardiology began to collaborate this last with interest on cardiac valves for graft. Starting from 1997, the International Atomic Energy Agency (IAEA) supports this project (MEX/7/008) whose main objective is to set up the basis to establish in Mexico a Radio sterilized Tissue Bank (amniotic membranes, skin, bones, tendons, cardiac valves, etc.) to be used with therapeutic purposes (grafts). The IAEA support has consisted in the equipment acquisition which is fundamental for the Tissue Bank performance such as an experimental irradiator, laminar flow bell, lyophilizer, vacuum sealer and special knives for tissues. Also visits to Mexico of experts have been authorized with the aim of advising to the personnel which participate in the project and scientific visits of this personnel to another tissue banks (Sri Lanka and Argentine). The establishment in Mexico of a Tissue bank will be a great benefit because it will have availability of distinct tissues for grafts and it will reduce the synthetic materials importation which is very expensive. (Author)

  1. Radiation sterilization of polymeric implant materials

    International Nuclear Information System (INIS)

    Bruck, S.D.; Mueller, E.P.

    1988-01-01

    High-energy irradiation sterilization of medical devices and implants composed of polymeric biomaterials that are in contact with tissue and/or blood, may adversely affect their long-term mechanical and/or biological performance (tissue and/or blood compatibility). Since many polymeric implants may contain trace quantities of catalysts and/or other additives, the effect of high-energy radiation on these additives, and possible synergistic effects with the polymer chains under the influence of high-energy radiation, must be considered. It is essential to indicate whether polymeric implants are used in short-term (acute) or long-term (chronic) applications. Relatively small changes in their physicochemical, mechanical, and biological properties may be tolerable in the short term, whereas similar changes may lead to catastrophic failures in long-term applications. Therefore, polymeric implants which are to be sterilized by high-energy irradiation should be carefully evaluated for long-term property changes which may be induced by the radiation

  2. Sterilization of fruit flies (Diptera: Tephritidae) with X-rays for sterile insect technique programs

    International Nuclear Information System (INIS)

    Mastrangelo, Thiago de Araujo

    2009-01-01

    Recent fear of acts of terrorism provoked an increase of delays and denials in the shipment of radioisotopes. This truly represented a menace to sterile insect production projects around the world. In order to validate the use of a new kind of low-energy Xray irradiator, a series of radiobiological studies on Ceratitis capitata (tsl-VIENNA 8 strain) (Wied., 1824) (Diptera: Tephritidae) and an Argentinean strain of Anastrepha fraterculus (Wied., 1830) (Diptera: Tephritidae) were carried out, also comparing biological effectiveness between X-rays and traditional γ radiation from 60 Co. Pupae 48- 24 h before adult emergence of C. capitata males and both sexes of A. fraterculus were irradiated with doses ranging from 15 to 120 Gy and 10 to 70 Gy respectively. Doses that induce 50, 90 and 99% of sterility were estimated and the hypothesis of Parallelism for the Probit equations was tested. Doses of 82.7 Gy of X-rays and 128.2 Gy of γ rays (thus, a RBE∼1.5) induced 99% sterility on medfly males. The fertility of A. fraterculus fertile females crossed with 41 Gy of X-rays and 62.7 Gy of γ rays decreased in 99% comparing with the control group (RBE∼1.5). 99% sterility of A. fraterculus irradiated females was achieved with 60-80 Gy (RBE∼0.7). The standard quality control parameters of fecundity, adult emergence, fliers and survival were not significantly affected by the two types of radiation (RBE∼1) either for medfly or A. fraterculus (p>0.01), being averages in conformity with the values required by FAO/IAEA/USDA. Only fecundity of irradiated A. fraterculus females was severely reduced with increasing doses and no egg was laid at 70 Gy of both radiations. There were no significant differences between X-rays and γ rays regarding mating indices (RSI for medfly, RII, ISI, MRPI and FRPI for A. fraterculus) (p>0.05), what indicated more random matings for fertile and sterile insects. The results demonstrated that no significant difference in biological

  3. 9. School of radiation sterilization and hygienization - Lectures

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9 School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  4. Female sterilization by tubal ligation at caesarean section in Makurdi ...

    African Journals Online (AJOL)

    Background: Female sterilization is an important tool in reducing unplanned pregnancy and maternal mortality in our environment. The aim of this study was to determine the incidence, sociodemographic characteristics, technique, effectiveness and complications associated with female sterilization by bilateral tubal ligation ...

  5. Objections to tubal sterilization: what reversibility can and cannot overcome.

    Science.gov (United States)

    Shain, R N

    1980-09-01

    In a study of 1074 women, 696 and 338 subjects would not seriously consider permanent and hypothetically reversible sterilization, respectively; they were asked to explain their feelings. The reason accounting for most objections to permanent sterilization (65%) was irreversibility and of the subjects who would not consider reversible sterilization or were unsure, 42.7% attributed their principal objection to unnecessary surgery, a factor at least currently intrinsic to the procedure and not readily overcome by education. Many of the remaining objections to both permanent and reversible sterilization may be amenable to change either through education or financial subsidies. In response to a question concerning female attractiveness subsequent to permanent sterilization, 3% of the sample felt attractiveness would decrease and 17.5% were unsure of the surgery's effect. Unsure responses were largely negative in character. This issue is important because of its relationship to intention to undergo sterilization. Upon consideration of reversible sterilization, negative and unsure responses significantly declined, even on the part of those women whose friends have had a poor experience with currently available procedures. Thus, whereas the option of reversibility cannot overcome objections to surgery, it does overcome those regarding permanency; moreover, the "temporary" character it bestows upon surgical sterilization appears to help certain individuals overcome their fears of losing their physical appeal as a result of such procedures.

  6. 9. School of radiation sterilization and hygienization - Presentations

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9. School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  7. Comparison of Sterile and Clean Dressing Techniques in Post ...

    African Journals Online (AJOL)

    Comparison of Sterile and Clean Dressing Techniques in Post-operative Surgical Wound Infection in a Chinese Healthcare Facility. ... of sterile and clean dressing techniques on wound management in a Chinese hospital, and to compare their impact on wound healing and the cost of the dressing materials with respect to ...

  8. Assessment of Non-Sterile Pharmaceutical Compounding Practices ...

    African Journals Online (AJOL)

    A descriptive cross-sectional survey was conducted to assess the practices of non-sterile pharmaceutical compounding in selected 42 community and 3 hospital pharmacies in Addis Ababa, Ethiopia from 01 April, 2016 to 15 May, 2016. The study revealed that the most commonly prescribed and compounded non-sterile ...

  9. Thermalisation of light sterile neutrinos in the early universe

    DEFF Research Database (Denmark)

    Hannestad, Steen; Tamborra, Irene; Tram, Thomas

    2012-01-01

    on the current cosmological data have been derived using simplified assumptions about thermalisation of the sterile neutrino at the Big Bang Nucleosynthesis (BBN) epoch. These assumptions are not necessarily justified and here we solve the full quantum kinetic equations in the (1 active + 1 sterile) scenario...

  10. Surface sterilization method for reducing microbial contamination of ...

    African Journals Online (AJOL)

    An effective disinfection method for strawberry (Fragaria x ananassa Duch.) cv. Senga Sengana micropropagation using runner tips and nodal segments as explants was developed. The explants were surface sterilized with different sterilants for different durations. The present studies on the effect of different regimes of ...

  11. 42 CFR 50.207 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207...

  12. Efficacy of gamma sterilization technique for biofertilizer carrier production

    International Nuclear Information System (INIS)

    Rallos, Roland V.; Rivera, Faye G.; Anarna, Julie A.; Rojales, Jacqueline S.

    2013-01-01

    Th use of gamma irradiation as sterilization technique for biofertilizer carrier is very efficient and practical especially in large scale production. The results of this study on the efficacy of gamma sterilization justify research on the effects of established doses of gamma irradiation on the physico-chemical properties of the clay-charcoal mixture

  13. The context and limitations of female sterilization services in Pakistan.

    Science.gov (United States)

    Khan, Adnan Ahmad; Khan, Ayesha; Abbas, Khadija; Tirmizi, Syed Farhan Ali; ul Islam, Zia

    2013-04-01

    Female sterilization has long been the most popular method of family planning (FP) in Pakistan, and yet most public health experts feel it contributes little to controlling family size or to population welfare. We used Pakistan Demographic Health Survey (PDHS) data to understand the role female sterilization plays in the overall context of FP in Pakistan. We performed a secondary analysis of data from the PDHS 1990-1 and 2006-7 to study factors that lead to sterilization and trends in the use of the procedure. In addition, census data were multiplied by proportions from PDHS data to estimate the number of women availing sterilization services. Around 1.9 million women in Pakistan are currently sterilized--up from 0.55 million in 1990-1, and around 173,867 undergo the procedure, annually. Women usually receive sterilization after 30 years of age (mean = 39) and after six children. The probability of sterilization increases with age, family size, and urban residence, and is unaffected by poverty, province of residence, or the woman or her husband's education. Most sterilizationis conducted in public sector facilities. Sterilization in Pakistan may be common, but occurs too late to have any significant effect on family size or benefit public health. Future avenues to make this option more useful to women and society would be to improve the repertoire and access and quality of FP services that are available, and to address governance issues that limit the performance and utility of government facilities.

  14. Nuclear-Cytoplasmic male-sterility in diploid dandelions

    NARCIS (Netherlands)

    van der Hulst, R.G.M.; Meirmans, P.; van Tienderen, P.H.; Van Damme, J.M.M.

    2004-01-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for

  15. Nuclear-cytoplasmic male-sterility in diploid dandelions

    NARCIS (Netherlands)

    van der Hulst, R.G.M.; Meirmans, P.G.; van Tienderen, P.H.; van Damme, J.M.M.

    2004-01-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for male

  16. A simple genetic incompatibility causes hybrid male sterility in mimulus.

    Science.gov (United States)

    Sweigart, Andrea L; Fishman, Lila; Willis, John H

    2006-04-01

    Much evidence has shown that postzygotic reproductive isolation (hybrid inviability or sterility) evolves by the accumulation of interlocus incompatibilities between diverging populations. Although in theory only a single pair of incompatible loci is needed to isolate species, empirical work in Drosophila has revealed that hybrid fertility problems often are highly polygenic and complex. In this article we investigate the genetic basis of hybrid sterility between two closely related species of monkeyflower, Mimulus guttatus and M. nasutus. In striking contrast to Drosophila systems, we demonstrate that nearly complete hybrid male sterility in Mimulus results from a simple genetic incompatibility between a single pair of heterospecific loci. We have genetically mapped this sterility effect: the M. guttatus allele at the hybrid male sterility 1 (hms1) locus acts dominantly in combination with recessive M. nasutus alleles at the hybrid male sterility 2 (hms2) locus to cause nearly complete hybrid male sterility. In a preliminary screen to find additional small-effect male sterility factors, we identified one additional locus that also contributes to some of the variation in hybrid male fertility. Interestingly, hms1 and hms2 also cause a significant reduction in hybrid female fertility, suggesting that sex-specific hybrid defects might share a common genetic basis. This possibility is supported by our discovery that recombination is reduced dramatically in a cross involving a parent with the hms1-hms2 incompatibility.

  17. Cleaning, disinfection and sterilization of surface prion contamination.

    Science.gov (United States)

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. [Determinants of sterilization among married couples in Korea].

    Science.gov (United States)

    Kim, Ju Hee; Chung, Woojin; Lee, Sunmi; Suh, Moonhee; Kang, Dae Ryong

    2007-11-01

    The purpose of this study was to examine the determinants of sterilization in South Korea. This study was based on the data from the Korea National Fertility Survey carried out in the year 2000 by the Korea Institute of Health and Social Affairs. The subjects of the analysis were 4,604 women and their husbands who were in their first marriage, in the age group of 15-49 years. The data were analyzed by multiple logistic regression analysis. Consistent with the findings of previous studies, the woman's age and the number of total children increased the likelihood of sterilization. In addition, the year of marriage had a strong positive association with sterilization. Interestingly, the number of surviving sons tended to increase the likelihood of sterilization, whereas the woman's education level and age at the time of marriage showed a negative association with sterilization. Religion, place of residence, son preference, and the husband's education level, age and type of occupation were not significant determinants of sterilization. The sex of previous children and lower level of education are distinct determinants of sterilization among women in South Korea. More studies are needed in order to determine the associations between sterilization rate and decreased fertility.

  19. History of the sterile insect technique

    International Nuclear Information System (INIS)

    Klassen, W.; Curtis, C.F.

    2005-01-01

    During the 1930s and 1940s the idea of releasing insects of pest species to introduce sterility (sterile insect technique or SIT) into wild populations, and thus control them, was independently conceived in three extremely diverse intellectual environments. The key researchers were A. S. Serebrovskii at Moscow State University, F. L. Vanderplank at a tsetse field research station in rural Tanganyika (now Tanzania), and E. F. Knipling of the United States Department of Agriculture. Serebrovskii's work on chromosomal translocations for pest population suppression could not succeed in the catastrophic conditions in the USSR during World War II, after which he died. Vanderplank used hybrid sterility to suppress a tsetse population in a large field experiment, but lacked the resources to develop this method further. Knipling and his team exploited H. J. Muller's discovery that ionizing radiation can induce dominant lethal mutations, and after World War II this approach was applied on an area-wide basis to eradicate the New World screwworm Cochliomyia hominivorax (Coquerel) in the USA, Mexico, and Central America. Since then very effective programmes integrating the SIT have been mounted against tropical fruit flies, some species of tsetse flies Glossina spp., the pink bollworm Pectinophora gossypiella (Saunders), and the codling moth Cydia pomonella (L.). In non-isolated onion fields in the Netherlands, the onion maggot Delia antiqua (Meigen) has since 1981 been suppressed by the SIT. In the 1970s there was much research conducted on mosquito SIT, which then went into 'eclipse', but now appears to be reviving. Development of the SIT for use against the boll weevil Anthonomus grandis grandis Boheman and the gypsy moth Lymantria dispar (L.) has ended, but it is in progress for two sweetpotato weevil species, Cylas formicarius (F.) and Euscepes postfasciatus (Fairmaire), the false codling moth Cryptophlebia leucotreta (Meyrick), the carob moth Ectomyelois ceratoniae

  20. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Krishnan, Vijaya

    2004-01-01

    Full Text Available EnglishPrior to early 1970s, traditional methods were the principal means ofcontrolling the number and spacing of births. Today, an estimated 57 per cent of the world's marriedwomen use contraceptives and half use modern methods such as medical sterilizations. Recent statisticssuggest that Canada has the highest sterilization rate in the Western world. This paper presentsfindings of research examining sterilization trends in Canada with respect to changing patterns in theuse of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligationand an increase in the use of hysterectomy over the period 1984-1995. Less educated women are morelikely to be in the forefront of modern methdos of contraception.FrenchAvant les années 1970, les méthodes traditionnelles représentaient le principalmoyen de contrôler et d’espacer le nombre de naissances. De nos jours, onestime que 57 pour cent des femmes mariées dans le monde entier utilisent unmoyen contraceptif et la moitié utilise des méthodes modernes telles que lastérilisation. Les dernières statistiques indiquent que le Canada compte le tauxde stérilisations le plus élevé dans le monde occidental. Cet article présente lesconclusions de recherches portant sur les tendances en matière de stérilisation auCanada en ce qui concerne les modèles changeants d’utilisation de moyens decontraception modernes et ce, à partir de données de l’Enquête canadienne sur lafécondité de 1984 et de l’Enquête sociale générale (ESG de 1995. La principaleconclusion qui en est ressortie est une réduction de la ligature des trompes etune augmentation du nombre d’hystérectomies de 1984 à 1995. Les femmesmoins éduquées sont plus portées à se trouver au premier plan des méthodes decontraception modernes.

  1. Portable Chemical Sterilizer for Microbial Decontamination of Surgical Instruments, Fruits and Vegetables, and Field Feeding Equipment

    National Research Council Canada - National Science Library

    Doona, C. J; Feeherry, F. E; Kustin, K; Curtin, M. A; Baer, D. G

    2006-01-01

    The Portable Chemical Sterilizer (PCS) is a revolutionary biomedical sterilization technology that provides the capability for portable, power-free, point-of-use sterilization to meet the Army's Far-Forward Surgical Teams (FSTs...

  2. The causes of genetic male sterility in 3 soybaen lines.

    Science.gov (United States)

    Rubaihayo, P R; Gumisiriza, G

    1978-11-01

    The cause of male sterility in 3 soybean lines, TGM 103-1, N-69-2774 and TGM 242-4 was studied. In TGM 103-1, which was both male and female sterile, two different abnormalities were associated with sterility. Precocious movement of a few chromosomes at the metaphase I stage resulted into the production of non-functional pollen while cells which underwent apparent normal meiotic division had disintergration of the tapetal cell wall immediately after the free microspore stage leading to the starvation and subsequent death of the developing microspores. In lines N-69-2774 and TGM 242-4, both of which were partially sterile, male sterility resulted from a failure of cytokinesis after the telophase II stage. Meiosis proceeded normally but the 4 microspores after telophase II failed to separate into pollen grains and degenerated thereafter.

  3. Hysteroscopic tubal sterilization: a systematic review of the Essure system

    DEFF Research Database (Denmark)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika

    2010-01-01

    OBJECTIVE: To update the evidence of the efficacy and safety of the Essure system. Female sterilization has undergone changes in the last decade. Besides laparoscopic tubal occlusion, the Essure system is now a viable option, with about 200,000 women sterilized using this method. DESIGN: The review...... in ambulatory settings. However, sterilization is not immediate and women must use additional contraception for 3 months until permanent tubal occlusion is verified by transvaginal ultrasound, hysterosalpingosonography, hysterosalpingography, or pelvic radiography. The evidence on efficacy and safety is mainly...... sterilization, but more information on the total cost is needed. CONCLUSION(S): The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published...

  4. Color stability of shade guides after autoclave sterilization.

    Science.gov (United States)

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  5. Post-sterilization autonomy among young mothers in South India.

    Science.gov (United States)

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  6. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  7. Methane potential of sterilized solid slaughterhouse wastes.

    Science.gov (United States)

    Pitk, Peep; Kaparaju, Prasad; Vilu, Raivo

    2012-07-01

    The aim of the current study was to determine chemical composition and methane potential of Category 2 and 3 solid slaughterhouse wastes rendering products (SSHWRP) viz. melt, decanter sludge, meat and bone meal (MBM), technical fat and flotation sludge from wastewater treatment. Chemical analyses showed that SSHWRP were high in protein and lipids with total solids (TS) content of 96-99%. Methane yields of the SSHWRP were between 390 and 978 m(3) CH(4)/t volatile solids (VS)(added). Based on batch experiments, anaerobic digestion of SSHWRP from the dry rendering process could recover 4.6 times more primary energy than the energy required for the rendering process. Estonia has technological capacity to sterilize all the produced Category 2 and 3 solid slaughterhouse wastes (SSHW) and if separated from Category 1 animal by-products (ABP), it could be further utilized as energy rich input material for anaerobic digestion. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Pressure-assisted thermal sterilization of soup

    Science.gov (United States)

    Shibeshi, Kidane; Farid, Mohammed M.

    2010-12-01

    The overall efficiency of an existing scale-up pressure-assisted thermal sterilization (PATS) unit was investigated with regards to inactivation of Geobacillus stearothermophilus spores suspended in pumpkin soup. The PATS unit is a double pipe heat exchanger in which the soup is pumped into its inner high pressure tube and constrained by two high pressure valves, while steam is continuously passed through the annular region to heat the content. The technology is based on pressure generation by thermal expansion of the liquid in an enclosure. In this work, the addition of an air line to push the treated liquid food out of the existing PATS unit has improved the overall quality of the treated samples, as evidenced by achieving higher log reduction of the spores. Compared with thermal processing, the application of PATS shows the potential for lowering the thermal treatment temperature, offering improved food quality.

  9. Twenty years of radiation sterilization in Croatia

    Science.gov (United States)

    Ražem, Dus̆an

    2004-09-01

    The development of radiation processing in Croatia is described from its inception 20 years ago up to the present time. Annual throughputs of treated materials are given by the categories of materials and pertaining volumes. The pasteurization of hard gelatine capsules occured during the early stages, while sterilization of disposable medical supplies has been dominant in the later stages. Irradiation of foods and of cosmetics and toiletries has been a minor fraction of the total throughput. Since the recovery of everyday life and economy of the country after the war, the total throughput has increased steadily to reach 13,000 m 3 kGy in 2002, 90% of which are medical supplies. Estimates of the present maximum capacity of 30,000 m 3 kGy and of future needs indicate that the present rate of growth could be sustained for the next several years only, unless a major upgrading is undertaken. An estimate of potential future needs is made.

  10. [The psychosocial background of sterile patients].

    Science.gov (United States)

    Pusch, H H; Urdl, W; Walcher, W

    1989-01-01

    The psychosocial background of 300 childless couples from the Infertility Clinic of the Department of Gynecology and Obstetrics, University of Graz, was evaluated by means of a questionnaire and statistical analysis of data from their files. Points of special interest were problems such as interactions of the couple, motivations for the desire of children, psychosomatics, andrological investigation within the gynecological department, sexual habits and motivation and compliance concerning investigations and treatment. 72% of the questionnaires were returned. 50% of the sterile couples preferred to attend the infertility clinic together. 26% felt restrictions in their sexual behaviour due to the unrealized desire of children, 48% expected improvements in their partnership if they could have children. Compliance of male partners concerning the regular intake of prescribed medicaments was 83%, 63% accepted to stop smoking in cases of pathospermia.

  11. Twenty years of radiation sterilization in Croatia

    International Nuclear Information System (INIS)

    Razem, Dusan

    2004-01-01

    The development of radiation processing in Croatia is described from its inception 20 years ago up to the present time. Annual throughputs of treated materials are given by the categories of materials and pertaining volumes. The pasteurization of hard gelatine capsules occured during the early stages, while sterilization of disposable medical supplies has been dominant in the later stages. Irradiation of foods and of cosmetics and toiletries has been a minor fraction of the total throughput. Since the recovery of everyday life and economy of the country after the war, the total throughput has increased steadily to reach 13,000 m 3 kGy in 2002, 90% of which are medical supplies. Estimates of the present maximum capacity of 30,000 m 3 kGy and of future needs indicate that the present rate of growth could be sustained for the next several years only, unless a major upgrading is undertaken. An estimate of potential future needs is made

  12. Heavy Sterile Neutrino in Dark Matter Searches

    Directory of Open Access Journals (Sweden)

    Paraskevi C. Divari

    2018-01-01

    Full Text Available Sterile neutrinos are possible dark matter candidates. We examine here possible detection mechanisms, assuming that the neutrino has a mass of about 50 keV and couples to the ordinary neutrino. Even though this neutrino is quite heavy, it is nonrelativistic with a maximum kinetic energy of 0.1 eV. Thus new experimental techniques are required for its detection. We estimate the expected event rate in the following cases: (i measuring electron recoil in the case of materials with very low electron binding; (ii low temperature crystal bolometers; (iii spin induced atomic excitations at very low temperatures, leading to a characteristic photon spectrum; (iv observation of resonances in antineutrino absorption by a nucleus undergoing electron capture; (v neutrino induced electron events beyond the end point energy of beta decaying systems, for example, in the tritium decay studied by KATRIN.

  13. Radiation treatment for sterilization of packaging materials

    International Nuclear Information System (INIS)

    Haji-Saeid, Mohammad; Sampa, Maria Helena O.; Chmielewski, Andrzej G.

    2007-01-01

    Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology

  14. [Mechanisms of urinary tract sterility maintenance].

    Science.gov (United States)

    Okrągła, Emilia; Szychowska, Katarzyna; Wolska, Lidia

    2014-06-02

    Physiologically, urine and the urinary tract are maintained sterile because of physical and chemical properties of urine and the innate immune system's action. The urinary tract is constantly exposed to the invasion of microorganisms from the exterior environment, also because of the anatomical placement of the urethra, in the vicinity of the rectum. Particularly vulnerable to urinary tract infections (UTI) are women (an additional risk factor is pregnancy), but also the elderly and children. The main pathogens causing UTI are bacteria; in 70-95% of cases it is the bacterium Escherichia coli. Infections caused by viruses and fungi are less common and are associated with decreased immunity, pharmacotherapy, or some diseases. Bacteria have evolved a number of factors that facilitate the colonization of the urinary tract: the cover and cell membrane antigens O and K1, lipopolysaccharide (LPS), fimbriae, pile and cilia. On the other hand, the human organism has evolved mechanisms to hinder colonization of the urinary tract: mechanisms arising from the anatomical structure of the urinary tract, the physicochemical properties of the urine and the activity of the innate immune system, also known as non-specific, which isolates and destroys pathogens using immunological processes, and the mechanisms for release of antimicrobial substances such as Tamm-Horsfall protein, mucopolysaccharides, immunoglobulins IgA and IgG, lactoferrin, lipocalin, neutrophils, cytokines and antimicrobial peptides. This review aims to analyze the state of knowledge on the mechanisms to maintain the sterility of the urinary tract used by the human organism and bacterial virulence factors to facilitate the colonization of the urinary tract.

  15. Mechanisms of urinary tract sterility maintenance

    Directory of Open Access Journals (Sweden)

    Emilia Okrągła

    2014-06-01

    Full Text Available Physiologically, urine and the urinary tract are maintained sterile because of physical and chemical properties of urine and the innate immune system’s action. The urinary tract is constantly exposed to the invasion of microorganisms from the exterior environment, also because of the anatomical placement of the urethra, in the vicinity of the rectum. Particularly vulnerable to urinary tract infections (UTI are women (an additional risk factor is pregnancy, but also the elderly and children. The main pathogens causing UTI are bacteria; in 70-95% of cases it is the bacterium Escherichia coli. Infections caused by viruses and fungi are less common and are associated with decreased immunity, pharmacotherapy, or some diseases. Bacteria have evolved a number of factors that facilitate the colonization of the urinary tract: the cover and cell membrane antigens O and K1, lipopolysaccharide (LPS, fimbriae, pile and cilia. On the other hand, the human organism has evolved mechanisms to hinder colonization of the urinary tract: mechanisms arising from the anatomical structure of the urinary tract, the physicochemical properties of the urine and the activity of the innate immune system, also known as non-specific, which isolates and destroys pathogens using immunological processes, and the mechanisms for release of antimicrobial substances such as Tamm-Horsfall protein, mucopolysaccharides, immunoglobulins IgA and IgG, lactoferrin, lipocalin, neutrophils, cytokines and antimicrobial peptides. This review aims to analyze the state of knowledge on the mechanisms to maintain the sterility of the urinary tract used by the human organism and bacterial virulence factors to facilitate the colonization of the urinary tract.

  16. Sterile neutrino search in the STEREO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Christian; Lindner, Manfred; Roca, Christian [MPIK (Germany)

    2016-07-01

    In neutrino oscillations, a canonical understanding has been established during the last decades after the measurement of the mixing angles θ{sub 12}, θ{sub 23}, θ{sub 13} via solar, atmospheric and, most recently, reactor neutrinos. However, the re-evaluation of the reactor neutrino theoretical flux has forced a re-analysis of most reactor neutrino measurements at short distances. This has led to an unexpected experimental deficit of neutrinos with respect to the theory that needs to be accommodated, commonly known as the ''reactor neutrino anomaly''. This deficit can be interpreted as the existence of a light sterile neutrino state into which reactor neutrinos oscillate at very short distances. The STEREO experiment aims to find an evidence of such oscillations. The ILL research reactor in Grenoble (France) operates at a power of 58MW and provides a large flux of electron antineutrinos with an energy range of a few MeV. These neutrinos will be detected in a 2000 liter organic liquid scintillator detector doped with Gadolinium and consisting of 6 cells stacked along the direction of the core. Given the proximity of the detector, neutrinos will only travel a few meters until they interact with the scintillator. The detector will be placed about 10 m from the reactor core, allowing STEREO to be sensitive to oscillations into the above mentioned neutrino sterile state. The project presents a high potential for a discovery that would impact deeply the paradigms of neutrino oscillations and in consequence the current understanding of particle physics and cosmology.

  17. Impact of moth suppression/eradication programmes using the sterile insect technique or inherited sterility

    International Nuclear Information System (INIS)

    Bloem, K.A.; Bloem, S.; Carpenter, J.E.

    2005-01-01

    Numerous lepidopteran species have been investigated as candidates for control using the sterile insect technique (SIT) or inherited sterility (IS). However to date only two programmes are operational - the pink bollworm containment programme in the San Joaquin Valley, California, USA, and the codling moth suppression programme in British Columbia, Canada. Both of these programmes have been highly successful in controlling the pest populations, reducing insecticide use, and improving interactions between growers and the general public. However, other benefits, including the positive economic impacts of these programmes, have not been fully quantified. Methods to reduce the cost of lepidopteran programmes might include combining the SIT/IS with other pest control tactics such as mating disruption or the release of natural enemies, the development of genetic sexing strains, or the application of molecular technologies to develop genetic markers and genetic sterility. In future the greatest potential for impact of lepidopteran SIT/IS programmes may be in combating key invasive threats such as the eradication of an outbreak of the painted apple moth in New Zealand. (author)

  18. Sewage sterilization through gamma radiation; Esterilização de esgoto através da radiação gama

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, D.V.; Teixeira, W.M.S. [Faculdade Casa Branca, SP (Brazil). Pós-Graduação de Proteção Radiológica em Aplicações Médicas, Industriais e Nucleares; Lima, C.M.A. [MAXIM Cursos, Rio de Janeiro-RJ (Brazil); Silva, F.C.A. da, E-mail: franciscodasilva13uk@gmail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Riode Janeiro, RJ (Brazil)

    2017-07-01

    Lack of sewage treatment and adequate sanitation conditions can contribute to the proliferation of numerous parasitic and infectious diseases in addition to water degradation. Approximately fifty types of infections can be transmitted from a sick to a healthy person through different pathways involving human excreta. Untreated sewage can contaminate water, food, hands, soil, etc. Epidemics of certain diseases such as typhoid, cholera, dysenteries, etc., and countless cases of worms are responsible for high mortality rates in third world countries. In the work the different techniques of sewage treatment by disinfestation and sterilization were analyzed, highlighting the use and the advantages of the gamma radiation as well as the aspects of the radiological protection involved. The technique of sewage sterilization using gamma radiation is a method of controlling bacteria and microorganisms. It is estimated that more than 200 large irradiators are in operation worldwide, of which 5 are in Brazil, for general sterilization use. These facilities use a large amount of radioactive material, in the order of millions of Becquerel, for sterilization with high doses of radiation, which can generate lethal doses in a few minutes. These industrial facilities use Cobalt-60, being classified by the International Atomic Energy Agency - IAEA as Category 1 of high risk, and must possess a high level of radiological protection to carry out the sterilization, standing out the defense in depth. Specific legislation on radiological protection should be drafted for safe work and avoid future radiation accidents.

  19. What do you mean you can't sterilize it? The reusable medical device matrix.

    Science.gov (United States)

    Stephens, Anne; Assang, AnnMarie

    2010-12-01

    begins with proper cleaning and processing of the surgical instruments. Surgical site infections can increase the length of stay and the cost of the patients' hospitalization, as well as increased risk, morbidity and even mortality. 1 Today's patients are far more informed than they were in the past. They can gather information from the internet as well as from television, radio, and print media. This knowledge empowers the patient to expect that their healthcare providers are practicing due diligence. It is the ethical duty and responsibility of nurses to provide safe, competent care while protecting the rights of the patient and being accountable to the professional governing bodies. In other words, we are advocates for both our patients and the healthcare system.2 Using both new and innovative instruments in the OR was, in the past, as simple as a surgeon requesting an instrument, the perioperative nurse ordering the instrument and CPD processing it for use in the OR. That is no longer the case. With a wide range of more complex instrumentation and an increasing focus on sterilization strategies, healthcare facilities have had to adopt a more rigorous approach. There are many challenges in the world of sterile processing. A common one, faced on a regular basis, is the provision of vague, inaccurate reprocessing recommendations from the medical device manufacturer. Canadian centres are not able to meet European standards for reprocessing. European cycles, often referred to as "Fractionated Steam Cycles", are different than the pre-vacuum steam cycles run in Canada.

  20. Use of sterile male technique for insects to eradicate red palm weevil

    International Nuclear Information System (INIS)

    Al-Turaihi, E.H.

    2012-01-01

    The date palm plantations in the Middle East countries are infested by a devastating insect which is called red palm weevil originally from India and spread firstly into the Arab Gulf countries through imported palm trees. Red palm weevil is mainly controlled by using synthetic chemical pesticides and aggregative pheromone traps. Use of chemical pesticides has dramatically increased during recent years and posed many poisoning cases, pollution of environment, killed beneficial and non-target insects. The aim of this study is to highlight the application of Sterile Insect Technique to suppress or eradicate red palm weevil. The results revealed that the application of Sterile Insect Technique to control cotton boll weevil (Anthonomus grandis) in USA could be considered as an ideal example to apply the Sterile Insect Technique against red palm weevil because both species have similarities such as : both are exotic pests; have protected larval and pupal stages; have limited hosts; have economic importance; have an aggregative pheromone that attracts males and females; that can be used for detection and survey; and finally both insects are Coleopterans belonging to the same family.

  1. Gamma ray induced male sterility mutant in lentil

    International Nuclear Information System (INIS)

    Srivastava, A.; Yadav, A.K.

    2001-01-01

    Full text: Male sterility refers to the failure of pollen grains to bring about effective fertilization, either due to structural default or physiological disfunctioning and has special significance in hybridization programmes. Male steriles have been produced in a number of crop plants like red gram, pigeon pea, mung bean, khesari and lentil. A completely male sterile mutant was isolated in Lens culinaris Medik, after seed treatment with 100 Gy dose of gamma rays. The male sterile mutant showed 100% pollen sterility but was morphologically more vigorous than the parent plants. It showed more branches and its leaves were bigger, more oblong and dark green. The number of flowers borne by the mutant was significantly higher than any other plant of the treatment. The size of the flowers was also increased but the anthers were smaller in size. Pollen grains were few in number, round in shape but empty and did not take up any stain, indicating that normal microsporogenesis had not taken place. This male sterile mutant was used as the female parent and pollinated with pollen of a parent. Four pods with one seed in each were formed indicating that the mutant was female fertile. The seeds were smaller than those of the parent variety and also dark coloured. The mutant showed increased vigour and flower number as compared to parental plants. Lentil is an important pulse crop and induction of variability in its germplasm is necessary for its improvement. Male steriles can be used conveniently in lentil hybridization programmes. (author)

  2. Radio-sterilization and processing of frozen human skin

    International Nuclear Information System (INIS)

    Zarate S, Herman; Aguirre H, Paulina; Silva R, Samy; Hitschfeld G, Mario

    2006-01-01

    The Laboratory of Radio-sterilized Biological Tissues Processing (LPTR) belonging to the Chilean Commission of Nuclear Energy and the International Atomic Energy Agency have played a paramount role in our country, concerning the biological tissue processing, which can be radio-sterilized as human skin, pig skin, amniotic membrane, human bone and bovine bone. The frozen radio.-sterilized human skin processing began in 2001, by means of putting into practice the knowledge acquired in training courses through the IAEA and the experience transferred by experts who visited our laboratory. The human skin processing of dead donor can be divided into 6 stages: a) Profuse washing with physiological sterilized serum in to remove the microorganisms, chemical and pharmacological compounds; b) immersion in glycerol solution at 10% to better keep the stored tissues; c) packing, to avoid post manipulation of the sterilized tissue; d) microbiological controls which allow and guarantee a sterility assurance level of 10 6 ; e) radio-sterilization, technique that consists of exposing the grafts to electromagnetic gamma waves which eliminate the microorganisms of the tissue, f) and finally, dispatching and liberation of the frozen sterilized human skin for its clinical use in different centers that take care of burned people. The LPTR receives feedback from surgeons who have used these tissues in order to improve the processing stages based in an integral quality system ISO 9001.2000. The State Health System in our country counts on limited and scarce resources to implement synthetic substitutes that is why It is considered necessary to spread the use of these noble tissues which have sterility assurance and they are processed at low price

  3. Geographic Variation in Characteristics of Postpartum Women Using Female Sterilization.

    Science.gov (United States)

    White, Kari; Potter, Joseph E; Zite, Nikki

    2015-01-01

    Southern states have higher rates of female sterilization compared with other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women's contraceptive method use between 2006 and 2009. We categorized states according to geographic region: South, Midwest/West, and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. The percentage of postpartum women using sterilization ranged from 5.0% to 9.9% in the Northeast, 8.9% to 10.6% in the Midwest/West, and 11.6% to 22.4% in the South. Women in nearly all subgroups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no differences in the prevalence of sterilization for Blacks compared with Whites in the Northeast (0.76; 95% CI, 0.55-1.06), Midwest/West (0.91; 95% CI, 0.80-1.04), and South (0.96; 95% CI, 0.85-1.07). Women with Medicaid-paid deliveries (vs. private insurance) had a higher prevalence of sterilization in all regions (p sterilization at disproportionately higher rates compared with other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  4. Gamma-irradiation sterilization of lipases for cheese making

    Energy Technology Data Exchange (ETDEWEB)

    Umanskij, M S; Borovkova, Yu A; Odegov, N I [Vsesoyuznyj Nauchno-Issledovatel' skij Inst. Maslodel' noj i Syrodel' noj Promyshlennosti, Uglich (USSR)

    1979-03-01

    The possibility of sterilizing the enzyme compounds of lipases from Oospora fragrans strains by gamma irradiation was studied. The enzyme compounds were exposed to gamma irradiation at the doses from 0.1 to 0.8 Mrad with the discreteness of 0.1 Mrad and at the dose of 2.0 Mrad. After the radiation treatment the lipases were investigated for bacterial invasion by the cultivation method and for the lipolytic activity by the titrometrical method. It is shown that the sterilization effect is achieved without losses of lipase activity and the radiation dose necessary for sterilization depends on initial invasion levels in the enzyme compounds.

  5. Sterility and meeting competitiveness of medfly, Ceratitis Capitata (Wiedemann)

    International Nuclear Information System (INIS)

    Taein-Tun; Molly-Maung-Maung

    2001-01-01

    The basic methodology in the determination of sterilising dosage in male med flies and mating competitiveness with the normal males was carried out in the laboratory. Application of the Sterile Insect Technique (S.I.T.) by three irradiation dosages on Seib-6096 pupae results in sterility when dosage increased. A lower mating competitiveness was observed with the increase in sterility value. This value was determined from the corrected egg hatch percent. The resulting data showed that irradiation dosage of γ 10.0 Krad gave a good advantage to suppress the population in the next generation. The method suggested a good application in the control and eradication of fruit flies. (author)

  6. Sterile Neutrino Search with the Double Chooz Experiment

    Science.gov (United States)

    Hellwig, D.; Matsubara, T.; Double Chooz Collaboration

    2017-09-01

    Double Chooz is a reactor antineutrino disappearance experiment located in Chooz, France. A far detector at a distance of about 1 km from reactor cores is operating since 2011; a near detector of identical design at a distance of about 400 m is operating since begin 2015. Beyond the precise measurement of θ 13, Double Chooz has a strong sensitivity to so called light sterile neutrinos. Sterile neutrinos are neutrino mass states not taking part in weak interactions, but may mix with known neutrino states. In this paper, we present an analysis method to search for sterile neutrinos and the expected sensitivity with the baselines of our detectors.

  7. Sterile neutrinos as the origin of dark and baryonic matter.

    Science.gov (United States)

    Canetti, Laurent; Drewes, Marco; Shaposhnikov, Mikhail

    2013-02-08

    We demonstrate for the first time that three sterile neutrinos alone can simultaneously explain neutrino oscillations, the observed dark matter, and the baryon asymmetry of the Universe without new physics above the Fermi scale. The key new point of our analysis is leptogenesis after sphaleron freeze-out, which leads to resonant dark matter production, evading thus the constraints on sterile neutrino dark matter from structure formation and x-ray searches. We identify the range of sterile neutrino properties that is consistent with all known constraints. We find a domain of parameters where the new particles can be found with present day experimental techniques, using upgrades to existing experimental facilities.

  8. Resonant Production of Sterile Neutrinos in the Early Universe

    Science.gov (United States)

    Gilbert, Lauren; Grohs, Evan; Fuller, George M.

    2016-06-01

    This study examines the cosmological impacts of a light resonantly produced sterile neutrino in the early universe. Such a neutrino could be produced through lepton number-driven Mikheyev-Smirnov-Wolfenstein (MSW) conversion of active neutrinos around big bang nucleosynthesis (BBN), resulting in a non-thermal spectrum of both sterile and electron neutrinos. During BBN, the neutron-proton ratio depends sensitively on the electron neutrino flux. If electron neutrinos are being converted to sterile neutrinos, this makes the n/p ratio a probe of possible new physics. We use observations of primordial Yp and D/H to place limits on this process.

  9. Bacterial spores survive treatment with commercial sterilants and disinfectants.

    Science.gov (United States)

    Sagripanti, J L; Bonifacino, A

    1999-09-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data obtained with a sensitive and quantitative test suggest that commercial liquid sterilants and disinfectants are less effective on contaminated surfaces than generally acknowledged.

  10. Use of radioimmunoassay to diagnose some forms of endocrine sterility

    International Nuclear Information System (INIS)

    Balabolkin, M.I.; Gerasimov, G.A.

    1984-01-01

    The possibility is considered of using a metoclopramide test combined with radioimmunoassay for determing prolactin in the blood to diagnose some forms of endocrine sterility Of 17 women examined 5 are practically healthy, sterility of 6 women is caused by tumor of hypophysis verified by X-rayograms, 6 women suffered from disorderded prolactin secretion and sterility without roentgenologic signs of disordered sella turcica. Metoclopramide has been injected intravenously in the 10 mm dose. A series of advantages is noted of the metoclopramide sample characteristic of high availability of the preparation and practically complete absence of side-effects

  11. Delayed pulsar kicks from the emission of sterile neutrinos

    International Nuclear Information System (INIS)

    Kusenko, Alexander; Mandal, Bhabani Prasad; Mukherjee, Alok

    2008-01-01

    The observed velocities of pulsars suggest the possibility that sterile neutrinos with mass of several keV are emitted from a cooling neutron star. The same sterile neutrinos could constitute all or part of cosmological dark matter. The neutrino-driven kicks can exhibit delays depending on the mass and the mixing angle, which can be compared with the pulsar data. We discuss the allowed ranges of sterile neutrino parameters, consistent with the latest cosmological and x-ray bounds, which can explain the pulsar kicks for different delay times

  12. The processing technology of bread crumbs sterilization by irradiation

    International Nuclear Information System (INIS)

    Zhu Jiating; Li Zhengkui; Zhao Yongfu; Zhang Weidong; Jin Jie; Wu Lei; Wang Xinghai

    2003-01-01

    The processing technology of bread crumbs sterilization by irradiation was studied. The results demonstrated that dose heterogeneity had osculatory connection with pile height and turning, sterilization effect had positive correlation with the irradiation dose and negative correlation with colour. Compared with the CK, the content of crud protein, fat, carbohydrate, microelement and amino acid in irradiated bread crumbs had no obvious change. It is recommended that the range of best sterilization dose be 6-10 kGy and the shelf time of bread crumbs be extended to one year

  13. Allelic interaction of F1 pollen sterility loci and abnormal chromosome behaviour caused pollen sterility in intersubspecific autotetraploid rice hybrids.

    Science.gov (United States)

    He, J H; Shahid, M Q; Li, Y J; Guo, H B; Cheng, X A; Liu, X D; Lu, Y G

    2011-08-01

    The intersubspecific hybrids of autotetraploid rice has many features that increase rice yield, but lower seed set is a major hindrance in its utilization. Pollen sterility is one of the most important factors which cause intersubspecific hybrid sterility. The hybrids with greater variation in seed set were used to study how the F(1) pollen sterile loci (S-a, S-b, and S-c) interact with each other and how abnormal chromosome behaviour and allelic interaction of F(1) sterility loci affect pollen fertility and seed set of intersubspecific autotetraploid rice hybrids. The results showed that interaction between pollen sterility loci have significant effects on the pollen fertility of autotetraploid hybrids, and pollen fertility further decreased with an increase in the allelic interaction of F(1) pollen sterility loci. Abnormal ultra-structure and microtubule distribution patterns during pollen mother cell (PMC) meiosis were found in the hybrids with low pollen fertility in interphase and leptotene, suggesting that the effect-time of pollen sterility loci interaction was very early. There were highly significant differences in the number of quadrivalents and bivalents, and in chromosome configuration among all the hybrids, and quadrivalents decreased with an increase in the seed set of autotetraploid hybrids. Many different kinds of chromosomal abnormalities, such as chromosome straggling, chromosome lagging, asynchrony of chromosome disjunction, and tri-fission were found during the various developmental stages of PMC meiosis. All these abnormalities were significantly higher in sterile hybrids than in fertile hybrids, suggesting that pollen sterility gene interactions tend to increase the chromosomal abnormalities which cause the partial abortion of male gametes and leads to the decline in the seed set of the autotetraploid rice hybrids. © 2011 The Author(s).

  14. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene.

    Science.gov (United States)

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-12-06

    The breeding and large-scale adoption of hybrid seeds is an important achievement in agriculture. Rice hybrid seed production uses cytoplasmic male sterile lines or photoperiod/thermo-sensitive genic male sterile lines (PTGMS) as female parent. Cytoplasmic male sterile lines are propagated via cross-pollination by corresponding maintainer lines, whereas PTGMS lines are propagated via self-pollination under environmental conditions restoring male fertility. Despite huge successes, both systems have their intrinsic drawbacks. Here, we constructed a rice male sterility system using a nuclear gene named Oryza sativa No Pollen 1 (OsNP1). OsNP1 encodes a putative glucose-methanol-choline oxidoreductase regulating tapetum degeneration and pollen exine formation; it is specifically expressed in the tapetum and miscrospores. The osnp1 mutant plant displays normal vegetative growth but complete male sterility insensitive to environmental conditions. OsNP1 was coupled with an α-amylase gene to devitalize transgenic pollen and the red fluorescence protein (DsRed) gene to mark transgenic seed and transformed into the osnp1 mutant. Self-pollination of the transgenic plant carrying a single hemizygous transgene produced nontransgenic male sterile and transgenic fertile seeds in 1:1 ratio that can be sorted out based on the red fluorescence coded by DsRed Cross-pollination of the fertile transgenic plants to the nontransgenic male sterile plants propagated the male sterile seeds of high purity. The male sterile line was crossed with ∼1,200 individual rice germplasms available. Approximately 85% of the F1s outperformed their parents in per plant yield, and 10% out-yielded the best local cultivars, indicating that the technology is promising in hybrid rice breeding and production.

  15. Belgian experience with radiation technologies for sterilization

    International Nuclear Information System (INIS)

    Bonet, H.; Dardenne, P.; Herier, A.

    1998-01-01

    Belgium pioneered in non energetic applications of nuclear science. In 1970, the National Institute for Radioisotopes (IRE) was founded on the ground of the experience acquired at the CEN/SCK, for developing nuclear techniques oriented to the well-being of population. In 1978 IRE started operation of 2 γ-irradiation units with a 2.25 million Ci Co 60 , source having a capacity for sterilization of more than 100 m 3 of product per day. this installation is currently operated by Griffith-Mediris (Group Griffith Micro Science) and has accumulated 20 years of experience for irradiation of foodstuffs, medical appliances and pharmaceuticals. In 1986, IRE was producing radioisotopes from accelerators and joined UCL for founding Ion Beam Applications (IBA) company which shortly became the world leader for design and delivery of cyclotrons. More recently, on the basis of French CEA patent, IBA developed the Rhodotron, an e-beam accelerator, with an X-ray option, which is now facing commercial success i area of ionization of food and medical appliances. IRE developed also expertise for the back-end of these activities i.e. final disposal of radioactive sealed source and dismantling of the installations. (author)

  16. Twenty years of radiation sterilization in Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Razem, Dusan E-mail: razem@irb.hr

    2004-10-01

    The development of radiation processing in Croatia is described from its inception 20 years ago up to the present time. Annual throughputs of treated materials are given by the categories of materials and pertaining volumes. The pasteurization of hard gelatine capsules occured during the early stages, while sterilization of disposable medical supplies has been dominant in the later stages. Irradiation of foods and of cosmetics and toiletries has been a minor fraction of the total throughput. Since the recovery of everyday life and economy of the country after the war, the total throughput has increased steadily to reach 13,000 m{sup 3} kGy in 2002, 90% of which are medical supplies. Estimates of the present maximum capacity of 30,000 m{sup 3} kGy and of future needs indicate that the present rate of growth could be sustained for the next several years only, unless a major upgrading is undertaken. An estimate of potential future needs is made.

  17. Transcriptional regulation of male-sterility in 7B-1 male-sterile tomato mutant.

    Directory of Open Access Journals (Sweden)

    Vahid Omidvar

    Full Text Available The 7B-1 tomato (Solanum lycopersicum L. cv Rutgers is a male-sterile mutant with enhanced tolerance to abiotic stress, which makes it a potential candidate for hybrid seed breeding and stress engineering. To underline the molecular mechanism regulating the male-sterility in 7B-1, transcriptomic profiles of the 7B-1 male-sterile and wild type (WT anthers were studied using mRNA sequencing (RNA-Seq. In total, 768 differentially expressed genes (DEGs were identified, including 132 up-regulated and 636 down-regulated transcripts. Gene ontology (GO enrichment analysis of DEGs suggested a general impact of the 7B-1 mutation on metabolic processes, such as proteolysis and carbohydrate catabolic process. Sixteen candidates with key roles in regulation of anther development were subjected to further analysis using qRT-PCR and in situ hybridization. Cytological studies showed several defects associated with anther development in the 7B-1 mutant, including unsynchronized anther maturation, dysfunctional meiosis, arrested microspores, defect in callose degradation and abnormal tapetum development. TUNEL assay showed a defect in programmed cell death (PCD of tapetal cells in 7B-1 anthers. The present study provides insights into the transcriptome of the 7B-1 mutant. We identified several genes with altered expression level in 7B-1 (including beta-1,3 glucanase, GA2oxs, cystatin, cysteine protease, pectinesterase, TA29, and actin that could potentially regulate anther developmental processes, such as meiosis, tapetum development, and cell-wall formation/degradation.

  18. Radiation sterilization of traditional medicine drugs in Vietnam

    International Nuclear Information System (INIS)

    Hang, N.D.; Canh, T.T.; Thuy, T.T.

    1995-01-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author)

  19. Radiation sterilization of plastic packing materials and aseptic packaging

    International Nuclear Information System (INIS)

    Tokuoka, Keiko

    1986-01-01

    In the present day of 'satiation', quality, not quantity, is emphasized for foods, the consumers being oriented toward raw and healthy foodstuff. Aseptic Packaging is excellent means of conservation. While conventionally chemicals have been used for sterilization of packing materials for aseptic packaging, the sterilization by radiation is used in part recently. The following are described : history of aseptic packaging and its features, sterilization by radiation, γ-ray sterilization of large-sized containers, the development of an aseptic packaging system using electron rays, the occurrence of offensive odors from packing materials (comparison of odors from various materials, volatile substances occurring in irradiated polyethylene, influence of film grade upon the formation of carboxylic acid, influence of the irradiation conditions upon the occurrences of volatile substances, volatile substances occurring in the irradiation of bag-in-box packing materials), changes in properties of the packing materials. (Mori, K.)

  20. Radiation sterilization of traditional medicine drugs in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Hang, N.D.; Canh, T.T.; Thuy, T.T. [Nuclear Research Inst., Da Lat (Viet Nam)

    1995-10-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author).

  1. Possibilities of sterilizing nutrient media used to grow tissue cultures

    International Nuclear Information System (INIS)

    Veber, P.; Leshko, Ya.; Gana, L.; Yankovicheva, T.; Yurmanova, K.

    1976-01-01

    Effects of radiosterilization on the properties of liquid and powdery Eagle's media and on inactivated calf and horse sera are described. It is shown that radiosterilization may be employed to sterilize biological agents required for in vitro cell cultivation. (author)

  2. Sterilization validation for medical compresses at IRASM multipurpose irradiation facility

    International Nuclear Information System (INIS)

    Alexandru, Mioara; Ene, Mihaela

    2007-01-01

    In Romania, IRASM Radiation Processing Center is the unique supplier of radiation sterilization services-industrial scale (ISO 9001:2000 and ISO 13485:2003 certified). Its Laboratory of Microbiological Testing is the sole third party competent laboratory (GLPractice License, ISO 17025 certification in progress) for pharmaceutics and medical devices as well. We here refer to medical compresses as a distinct category of sterile products, made from different kind of hydrophilic materials (cotton, non-woven, polyurethane foam) with or without an impregnated ointment base (paraffin, plant extracts). These products are included in the class of medical devices, but for the sterilization validation, from microbiological point of view, there are important differences in testing method compared to the common medical devices (syringes, catheters, etc). In this paper, we present some results and practical solutions chosen to perform a sterilization validation, compliant with ISO 11137: 2006

  3. Eugenics, sterilization, and historical memory in the United States

    Directory of Open Access Journals (Sweden)

    Alexandra Minna Stern

    Full Text Available Abstract From the 1920s to the 1950s, California sterilized approximately 20,000 people in state homes and hospitals based on a eugenic law that authorized medical superintendents to perform reproductive surgeries on patients deemed unfit and “suffering from a mental affliction likely to be inherited.” Working with a unique resource – a dataset created from 19,000 sterilization recommendations – my team and I have reconstructed patterns and experiences of institutionalization of sterilizations. This article presents several of our important initial findings related to ethnic and gender bias in sterilization policies, and reflects on the relevance of the history for contemporary issues in genomics and social justice.

  4. Steam sterilization costs: a guide for the central service manager.

    Science.gov (United States)

    O'Shaughnessy, K L

    1993-07-01

    The Nassau County Medical Center CS department, East Meadow, New York, was faced with a staff layoff and an increased workload. With some hard thinking and strong staff support, new processes/systems were designed to save time and money. These included outsourcing the sterilization of "easy" trays, instituting a case cart program and developing custom packs. In order to determine where savings could be had, it was first important to examine current costs. By breaking the costs of sterilization processing down into an average cost per load, a formula was developed that helped determine many additional cost comparisons for the department. For example, the cost analysis formula could be used by CS departments to determine the cost-effectiveness of off-site sterilization, to compare using disposable vs. reusable items and to determine costs for EtO sterilization and aeration.

  5. Clean Air Act Standards and Guidelines for Sterilizers

    Science.gov (United States)

    This page contains the stationary sources of air pollution for the sterilizer industries, and their corresponding air pollution regulations. To learn more about the regulations for each industry, just click on the links below.

  6. Cosmological lepton asymmetry, primordial nucleosynthesis and sterile neutrinos

    Science.gov (United States)

    Abazajian, Kevork; Bell, Nicole F.; Fuller, George M.; Wong, Yvonne Y. Y.

    2005-09-01

    We study post weak decoupling coherent active-sterile and active-active matter-enhanced neutrino flavor transformation in the early Universe. We show that flavor conversion efficiency at Mikheyev-Smirnov-Wolfenstein resonances is likely to be high (adiabatic evolution) for relevant neutrino parameters and energies. However, we point out that these resonances cannot sweep smoothly and continuously with the expansion of the Universe. We show how neutrino flavor conversion in this way can leave both the active and sterile neutrinos with nonthermal energy spectra, and how, in turn, these distorted energy spectra can affect the neutron-to-proton ratio, primordial nucleosynthesis, and cosmological mass/closure constraints on sterile neutrinos. We demonstrate that the existence of a light sterile neutrino which mixes with active neutrinos can change fundamentally the relationship between the cosmological lepton numbers and the primordial nucleosynthesis He4 yield.

  7. Postpartum Sterilization Choices Made by HIV-Infected Women

    Directory of Open Access Journals (Sweden)

    Gretchen S. Stuart

    2005-01-01

    Full Text Available Objective. To assess if HIV-infected women made different choices for postpartum sterilization after implementation of the Pediatric AIDS Clinical Trials Group protocol 076 (November 1, 1994 compared to before implementation.

  8. Design, Construction and Evaluation of a Dry Solar Sterilizer

    International Nuclear Information System (INIS)

    Hernández Fereira, Arcelio A.

    2017-01-01

    The objective of the work was the search of an alternative for sterilization using solar energy. For such purposes, a dry solar sterilizer of 4276 cm3 capacity was designed, constructed and evaluated. Potential users would be rural medical posts in areas without electricity, health posts in military units under field conditions, and experimental microbiology stations. The evaluation included the determination of the energy efficiency of the sterilizer, the economic evaluation against other variants and the biological safety assessment. The developed equipment reached the sterilization temperature for levels of the direct component of the solar radiation higher than 300 W/m2 in 14 minutes, corresponding to an average heating rate of 13 0C/minute, higher than that of an electric furnace. Its energy efficiency with direct solar radiation of 310.5 W/m2 was 53.79%. The equipment is of easy construction, simple operation and very low cost. (author)

  9. Degradation and stability of polycarbonate sterilized by gamma rays

    International Nuclear Information System (INIS)

    Araujo, E.S.; Guedes, S.M.L.

    1995-01-01

    The purpose of this paper is to study the behavior of the polycarbonate (poly (bis phenol-A carbonate)) when it is sterilized by gamma rays because undesirable discoloration appears. Aromatic polycarbonates are amorphous polymers usually prepared from bis phenols and phosgene by interfacial polymerization. They are employed in medical applications, including blood filters, dialyzers, oxygenators and sterilizing equipment. At present, the best process for sterilization of medical supplies is present, the best process for sterilization of medical supplies is gamma irradiation. The two major effects of γ-radiation in polymers are crosslinking and main chain scission. Both effects coexist and either one may predominate depending on the chemical structure of the polymer and the conditions of irradiation. (author). 5 refs, 6 figs, 1 tab

  10. The role of meiotic drive in hybrid male sterility.

    Science.gov (United States)

    McDermott, Shannon R; Noor, Mohamed A F

    2010-04-27

    Meiotic drive causes the distortion of allelic segregation away from Mendelian expected ratios, often also reducing fecundity and favouring the evolution of drive suppressors. If different species evolve distinct drive-suppressor systems, then hybrid progeny may be sterile as a result of negative interactions of these systems' components. Although the hypothesis that meiotic drive may contribute to hybrid sterility, and thus species formation, fell out of favour early in the 1990s, recent results showing an association between drive and sterility have resurrected this previously controversial idea. Here, we review the different forms of meiotic drive and their possible roles in speciation. We discuss the recent empirical evidence for a link between drive and hybrid male sterility, also suggesting a possible mechanistic explanation for this link in the context of chromatin remodelling. Finally, we revisit the population genetics of drive that allow it to contribute to speciation.

  11. Mating competitiveness of sterile male Anopheles coluzzii in large cages.

    Science.gov (United States)

    Maïga, Hamidou; Damiens, David; Niang, Abdoulaye; Sawadogo, Simon P; Fatherhaman, Omnia; Lees, Rosemary S; Roux, Olivier; Dabiré, Roch K; Ouédraogo, Georges A; Tripet, Fréderic; Diabaté, Abdoulaye; Gilles, Jeremie R L

    2014-11-26

    Understanding the factors that account for male mating competitiveness is critical to the development of the sterile insect technique (SIT). Here, the effects of partial sterilization with 90 Gy of radiation on sexual competitiveness of Anopheles coluzzii allowed to mate in different ratios of sterile to untreated males have been assessed. Moreover, competitiveness was compared between males allowed one versus two days of contact with females. Sterile and untreated males four to six days of age were released in large cages (~1.75 sq m) with females of similar age at the following ratios of sterile males: untreated males: untreated virgin females: 100:100:100, 300:100:100, 500:100:100 (three replicates of each) and left for two days. Competitiveness was determined by assessing the egg hatch rate and the insemination rate, determined by dissecting recaptured females. An additional experiment was conducted with a ratio of 500:100:100 and a mating period of either one or two days. Two controls of 0:100:100 (untreated control) and 100:0:100 (sterile control) were used in each experiment. When males and females consort for two days with different ratios, a significant difference in insemination rate was observed between ratio treatments. The competitiveness index (C) of sterile males compared to controls was 0.53. The number of days of exposure to mates significantly increased the insemination rate, as did the increased number of males present in the untreated: sterile male ratio treatments, but the number of days of exposure did not have any effect on the hatch rate. The comparability of the hatch rates between experiments suggest that An. coluzzii mating competitiveness experiments in large cages could be run for one instead of two days, shortening the required length of the experiment. Sterilized males were half as competitive as untreated males, but an effective release ratio of at least five sterile for one untreated male has the potential to impact the fertility of

  12. Periodontal instrumentation for the general dental practitioner: Pt. 2. Management maintenance and sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Touyz, L.Z.G. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Oral Medicine and Periodontology); De Waal, J.

    1983-03-01

    The purpose of this article is to describe the management, maintenance and sterilization of periodontal instrumentation used by the general dental practitioner. The pre-sterilization, decontamination and cleaning, the sharpening of instrumentation and the packaging, identification and grouping for sterilization are discussed. Attention is also given to various techniques of sterilization, including gamma radiation.

  13. Guide for dosimetry for sterile insect release programs. 2. ed.

    International Nuclear Information System (INIS)

    2004-01-01

    This guide outlines dosimetric procedures to be followed for the radiation sterilization of live insects for use in pest management programs. The primary use of irradiated, reproductively sterile insects is in the Sterile Insect Technique, where large numbers of sterile insects are released into the field to mate with and thus control pest populations of the same species. A secondary use of sterile insects is as benign hosts for rearing insect parasitoids. The procedures outlined in this guide will help ensure that insects processed with ionizing radiation from gamma, electron, or X-ray sources receive absorbed doses within a predetermined range. Information on effective dose ranges for specific applications of insect sterilization, or on methodology for determining effective dose ranges, is not within the scope of this guide. Note: Dosimetry is only one component of a total quality control program to ensure that irradiated insects are adequately sterilized and sufficiently competitive or otherwise suitable for their intended purpose. This guide covers dosimetry in the irradiation of insects for these types of irradiators: self-contained dry-storage 137 Cs or 60 Co irradiators, large-scale gamma irradiators, and electron accelerators. Additional, detailed information on dosimetric procedures to be followed in installation qualification, operational qualification, performance qualification, and routine product processing can be found in ISO/ASTM Practices 51608 (X-ray [bremsstrahlung] facilities), 51649 (electron beam facilities), 51702 (large-scale gamma facilities), and ASTM Practice E 2116 (self-contained dry-storage gamma facilities). The absorbed dose for insect sterilization is typically within the range of 20 Gy to 600 Gy

  14. Sterilization of Lung Matrices by Supercritical Carbon Dioxide.

    Science.gov (United States)

    Balestrini, Jenna L; Liu, Angela; Gard, Ashley L; Huie, Janet; Blatt, Kelly M S; Schwan, Jonas; Zhao, Liping; Broekelmann, Tom J; Mecham, Robert P; Wilcox, Elise C; Niklason, Laura E

    2016-03-01

    Lung engineering is a potential alternative to transplantation for patients with end-stage pulmonary failure. Two challenges critical to the successful development of an engineered lung developed from a decellularized scaffold include (i) the suppression of resident infectious bioburden in the lung matrix, and (ii) the ability to sterilize decellularized tissues while preserving the essential biological and mechanical features intact. To date, the majority of lungs are sterilized using high concentrations of peracetic acid (PAA) resulting in extracellular matrix (ECM) depletion. These mechanically altered tissues have little to no storage potential. In this study, we report a sterilizing technique using supercritical carbon dioxide (ScCO2) that can achieve a sterility assurance level 10(-6) in decellularized lung matrix. The effects of ScCO2 treatment on the histological, mechanical, and biochemical properties of the sterile decellularized lung were evaluated and compared with those of freshly decellularized lung matrix and with PAA-treated acellular lung. Exposure of the decellularized tissue to ScCO2 did not significantly alter tissue architecture, ECM content or organization (glycosaminoglycans, elastin, collagen, and laminin), observations of cell engraftment, or mechanical integrity of the tissue. Furthermore, these attributes of lung matrix did not change after 6 months in sterile buffer following sterilization with ScCO2, indicating that ScCO2 produces a matrix that is stable during storage. The current study's results indicate that ScCO2 can be used to sterilize acellular lung tissue while simultaneously preserving key biological components required for the function of the scaffold for regenerative medicine purposes.

  15. How self-interactions can reconcile sterile neutrinos with cosmology.

    Science.gov (United States)

    Hannestad, Steen; Hansen, Rasmus Sloth; Tram, Thomas

    2014-01-24

    Short baseline neutrino oscillation experiments have shown hints of the existence of additional sterile neutrinos in the eV mass range. However, such neutrinos seem incompatible with cosmology because they have too large of an impact on cosmic structure formation. Here we show that new interactions in the sterile neutrino sector can prevent their production in the early Universe and reconcile short baseline oscillation experiments with cosmology.

  16. Pharmaceutical aerosols. Study of their gamma radiation sterilization

    International Nuclear Information System (INIS)

    Sebert, P.

    1984-10-01

    The gamma radiation sterilization of pharmaceutical aerosols was studied. The following topics were investigated: radiosterilization of nitrogen protoxide used as a propellant; radiosterilization of packaging materials (aluminium containers, plastics valves); radio-sterilization of excipients and active ingredients. Most of the investigated materials proved to be stable to irradiation (2,5 Mrads) from pharmacopoeial aspect. Stability tests of the preparations packaged showed no change in the parameters investigated [fr

  17. Hysteroscopic tubal sterilization: a systematic review of the Essure system.

    Science.gov (United States)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika; Grahn, Riitta; Kukkonen-Harjula, Katriina; Nord-Saari, Merja; Mäkelä, Marjukka

    2010-06-01

    To update the evidence of the efficacy and safety of the Essure system. Female sterilization has undergone changes in the last decade. Besides laparoscopic tubal occlusion, the Essure system is now a viable option, with about 200,000 women sterilized using this method. The review is based on the report of the Alberta Heritage Foundation for Medical Research and completed with systematic literature searches up to April 8, 2008. The Managed Uptake of Medical Methods program of the Finnish National Research and Development Center for Health and Welfare. Women over 30 years, who had been sterilized by the Essure method. Hysteroscopic tubal sterilization using Essure system. Efficacy/effectiveness, adverse events, costs. Sterilization by Essure can be performed under local anesthesia or with oral analgesics in ambulatory settings. However, sterilization is not immediate and women must use additional contraception for 3 months until permanent tubal occlusion is verified by transvaginal ultrasound, hysterosalpingosonography, hysterosalpingography, or pelvic radiography. The evidence on efficacy and safety is mainly available from short follow-up case series but shows good efficacy and safety of the Essure system. Only a few small risks are associated with the procedure. Two economic studies, one of which implemented Essure as an in-office procedure, suggest that Essure could be more cost-effective than laparoscopic sterilization, but more information on the total cost is needed. The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  18. Bacterial Spores Survive Treatment with Commercial Sterilants and Disinfectants

    OpenAIRE

    Sagripanti, Jose-Luis; Bonifacino, Aylin

    1999-01-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data ob...

  19. Genetic complexity underlying hybrid male sterility in Drosophila.

    OpenAIRE

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-01-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic b...

  20. Evaluation of surgical gloves for radiation protection

    International Nuclear Information System (INIS)

    Antolin, E.; Rot, M.J.; Ordonez, J.; Arranz, L.; Sastre, J.M.; Ferrer, N.; Andres, J.C. de

    2006-01-01

    Full text of publication follows: Accumulated doses in hands during interventionist cardiology and radiological procedures can reach high values, and even go beyond legal limits for exposed professionals after years of work, unless they use specific radiation protection methods. An important protection mean for hands is the use of surgical gloves that attenuate the radiation while maintaining the tactile sensitivity demanded by physicians.There is a wide variety of commercialized gloves for radiation protection, with different advantages and disadvantages for various uses. In this paper nine different models of gloves have been evaluated for testing its attenuation capacity for several voltages, the maintenance of tactile sensitivity, its resistance to elongation, and the apparition of pores after successive sterilizing processes. It is very important that they do not lose its initial characteristics after processes of sterilization in order to optimize the product effective cost. The attenuation values have been measured under the voltages of 60, 70, 80 and 90 KVp obtaining very different values at each voltage with different gloves. The values measured range between 34 % before any supplementary sterilization with one model of glove (for 90 KVp), and 57 % after four sterilization processes with another glove (for 60 KVp). Some gloves lose its attenuation capacity after successive sterilizations, having not been found an y significant relation with their composition. The tactile sensitivity, a decisive factor for its users, decreases as its attenuation capacity increases, and remains mostly constant after being sterilized. The tests performed allow to conclude a set of fi nal results that can facilitate the choice of the most suitable gloves according to the practical applications (the priorities being the radiation protection and the tactile sensitivity)

  1. Gamma radiations an effective way of monoclonal antibodies sterilization

    International Nuclear Information System (INIS)

    Lenay Barrera Barroso, Lenay; Otero Abreu, Isabel; Rodriguez Napoles, Dania; Bulte Ocanna, Dubhe; Caballero, Idania

    2006-01-01

    The sterilization for radiations of pharmaceutical products is an effective, sure and reliable procedure; that it have been proving technically and grateful for different pharmacopoeia. The Monoclonal Antibodies (Acm) produced in the Center of Molecular Immunology (CIM) are products parenteral for the one which results indispensable that they complete the requirements of established sterility. The radio sterilization result the method more recommend for the sterilization of the Acm deep drying, due to the contained first floor of humidity remnant that minimizes the formation of sub-product that they affect their properties. With the objective of proposing a good dose of irradiation for the sterilization, we were carried out a study of the radius sensibility so much of the product like of the polluting of greater frequency of isolation of the clean area of the CIM. The characterization of the radius sensibility of the different micro- organisms was determined by D 10 characteristic of each isolated strains. From the developed studies the Gram-positive rods endospore-forming were the most resistant strains at the deep drying, the radiations and they were of the greater frequency of apparition in the carried out isolations. We could conclude that utilizing a dose of 10 kGy it is possible to eliminate of the pollution more radio resistant, assuring the sterility required in the product, and without inducing effects under desire radiolytic in the same

  2. A search for sterile neutrinos with the latest cosmological observations

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Lu; Zhang, Jing-Fei [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Zhang, Xin [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Peking University, Center for High Energy Physics, Beijing (China)

    2017-06-15

    We report the result of a search for sterile neutrinos with the latest cosmological observations. Both cases of massless and massive sterile neutrinos are considered in the ΛCDM cosmology. The cosmological observations used in this work include the Planck 2015 temperature and polarization data, the baryon acoustic oscillation data, the Hubble constant direct measurement data, the Planck Sunyaev-Zeldovich cluster counts data, the Planck lensing data, and the cosmic shear data. We find that the current observational data give a hint of the existence of massless sterile neutrino (as dark radiation) at the 1.44σ level, and the consideration of an extra massless sterile neutrino can indeed relieve the tension between observations and improve the cosmological fit. For the case of massive sterile neutrino, the observations give a rather tight upper limit on the mass, which implies that actually a massless sterile neutrino is more favored. Our result is consistent with the recent result of neutrino oscillation experiment done by the Daya Bay and MINOS collaborations, as well as the recent result of cosmic ray experiment done by the IceCube collaboration. (orig.)

  3. Development of atmospheric pressure plasma needle jet for sterilization applications

    Science.gov (United States)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Soon, Chin Fhong; Sahdan, Mohd Zainizan; Lias, Jais; Wibowo, Kusnanto Mukti; Bakar, Ahmad Shuhaimi Abu; Arshad, Mohd Khairuddin Md; Hashim, Uda; Nayan, Nafarizal

    2017-09-01

    Inactivation of bacteria or sterilization has been a major issue in the medical field, especially regarding of human safety, whereby, in a huge scenario fatality can be caused by hazardous bacteria. Often, E-coli as gram-negative bacteria are selected as a key indicator of proper sterilization process as E-coli is tough and dormant bacteria. The technology in sterilization has moved on from chemical, wet and irradiation sterilization to a high promising device such as atmospheric pressure plasma needle jet (APPNJ). It has been reported that atmospheric pressure plasma has provided bundle of advantages over earlier sterilization process. The APPNJ is developed in our lab using high frequency and high voltage neon transformer power supply connected to copper needle and copper sheet electrodes. The gas discharge is Ar gas flowing at 40 L/min through a quartz glass tube. The E-coli bacteria are self-cultured from waste water and then treated with APPNJ. The treatment processes are run into two difference gaps between the plasma orifice and sample with various treatment times. Only 40s is required by direct treatment to achieve 100% killing of E-coli. On the other hand, indirect treatment has inactivated 50% of the E-coli in 40s. In this study, direct and indirect effect of APPNJ to the E-coli can be observed which can be utilized into sterilization of bio-compatible material applications.

  4. Sterilizing elastomeric chains without losing mechanical properties. Is it possible?

    Directory of Open Access Journals (Sweden)

    Matheus Melo Pithon

    2015-06-01

    Full Text Available OBJECTIVE: To investigate the effects of different sterilization/disinfection methods on the mechanical properties of orthodontic elastomeric chains. METHODS: Segments of elastomeric chains with 5 links each were sent for sterilization by cobalt 60 (Co60 (20 KGy gamma ray technology. After the procedure, the elastomeric chains were contaminated with clinical samples of Streptococcus mutans. Subsequently, the elastomeric chains were submitted to sterilization/disinfection tests carried out by means of different methods, forming six study groups, as follows: Group 1 (control - without contamination, Group 2 (70°GL alcohol, Group 3 (autoclave, Group 4 (ultraviolet, Group 5 (peracetic acid and Group 6 (glutaraldehyde. After sterilization/disinfection, the effectiveness of these methods, by Colony forming units per mL (CFU/mL, and the mechanical properties of the material were assessed. Student's t-test was used to assess the number of CFUs while ANOVA and Tukey's test were used to assess elastic strength. RESULTS: Ultraviolet treatment was not completely effective for sterilization. No loss of mechanical properties occurred with the use of the different sterilization methods (p > 0.05. CONCLUSION: Biological control of elastomeric chains does not affect their mechanical properties.

  5. Remodeling of ACL Allografts is Inhibited by Peracetic Acid Sterilization

    Science.gov (United States)

    Gonnermann, Johannes; Kamp, Julia; Przybilla, Dorothea; Pruss, Axel

    2008-01-01

    Sterilization of allografts for anterior cruciate ligament (ACL) reconstruction has become an important prerequisite to prevent disease transmission. However, current sterilization techniques impair the biological or mechanical properties of such treated grafts. Peracetic acid (PAA) has been successfully used to sterilize bone allografts without these disadvantages and does not impair the mechanical properties of soft tissue grafts in vitro. We asked whether PAA sterilization would influence recellularization, restoration of crimp length and pattern, and revascularization of ACL grafts during early healing. We used an in vivo sheep model for open ACL reconstruction. We also correlated the histologic findings with the restoration of anteroposterior stability and structural properties during load-to-failure testing. PAA slowed remodeling activity at 6 and 12 weeks compared to nonsterilized allografts and autografts. The mechanical properties of PAA grafts were also reduced compared to these control groups at both time points. We conclude PAA sterilization currently should not be used to sterilize soft tissue grafts typically used in ACL reconstruction. PMID:18491201

  6. Effects of Sterilization Cycles on PEEK for Medical Device Application

    Science.gov (United States)

    Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-01-01

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed. PMID:29466289

  7. Effect of fermentation and sterilization on anthocyanins in blueberry.

    Science.gov (United States)

    Nie, Qixing; Feng, Lei; Hu, Jielun; Wang, Sunan; Chen, Haihong; Huang, Xiaojun; Nie, Shaoping; Xiong, Tao; Xie, Mingyong

    2017-03-01

    Blueberry products have various health benefits due to their high content of dietary anthocyanins. The aim of this study was to investigate the impact of fermentation and sterilization on total anthocyanin content, composition and some quality attributes of blueberry puree. The blueberry puree used here was fermented for 40 h at 37 °C by Lactobacillus after sterilization. The method of ultra-performance liquid chromatography-mass spectrometry was optimized for the rapid analysis of anthocyanins. Quality attributes including pH, color, total soluble solids and viscosity were measured. A total of 21 anthocyanins and five anthocyanidins were quantified by ultra-performance liquid chromatography. Fermented blueberry had reduced total anthocyanin content (29%) and levels of individual anthocyanins compared with fresh blueberry. Total anthocyanin content was decreased 46% by sterilization, and different degradation behavior of individual anthocyanin was appeared between fermented and sterilized-fermented blueberry puree. Fermentation and sterilization decreased the total soluble solids and pH and changed color parameters, while minimally influencing viscosity. The loss of total anthocyanin content by fermentation was related to the unstable structure of blueberry anthocyanins. Anthocyanins are sensitive to temperature (>80 °C), and degradation of anthocyanins by sterilization in blueberry should be considered in the fermentation procedure. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  8. Sterile Neutrino Search in the NOvA Far Detector

    Energy Technology Data Exchange (ETDEWEB)

    Edayath, Sijith [Cochin U.; Aurisano, Adam [Cincinnati U.; Sousa, Alexandre [Cincinnati U.; Davies, Gavin [Indiana U.; Suter, Louise [Fermilab; Yang, Shaokai [Cincinnati U.

    2017-10-03

    The majority of neutrino oscillation experiments have obtained evidence for neutrino oscillations that are compatible with the three-flavor model. Explaining anomalous results from short-baseline experiments, such as LSND and MiniBooNE, in terms of neutrino oscillations requires the existence of sterile neutrinos. The search for sterile neutrino mixing conducted in NOvA uses a long baseline of 810 km between Near Detector (ND) at Fermilab and Far Detector (FD) in Minnesota. The signal for sterile neutrino oscillations is a deficit of neutral-current neutrino interactions at the FD with respect to the ND prediction. In this document, We will present the analysis improvements that we are implementing for future NC sterile neutrino searches with NOvA. These include: improved modelling of our detector response; the inclusion of NC 2p2h interaction modelling; implementing a better energy reconstruction techniques; and including possible oscillation due to sterile neutrinos in the ND . This improvements enable us to do a simultaneous ND-FD shape fit of the NC energy spectrum covering a wider sterile mass range than previous analyses.

  9. Sterilization techniques without heating (ultraviolet ray, radiation and ozone)

    International Nuclear Information System (INIS)

    Ito, Hitoshi

    1991-01-01

    The recent demand of consumers for processed foods is characterized by the intention for health and nature, besides, the demand for low sweetness, salt reduction, no additive and freshness becomes strong. In view of the control of microorganisms in products, all these become the negative factors. Accordingly, in order to overcome them, it is urgently desired to develop new technology or to improve conventional methods. As to heating sterilization, the uniform temperature treatment to the inside of foods is difficult, and it cannot be applied to perishables. The high temperature sterilization above 120degC causes the change in nutrition composition and physical properties. Ultraviolet ray and ozone can be used for the sterilization of food surface and powder and liquid foods. Radiation treatment can be applied to packed foods and frozen foods as well as food surface. The principle and the fields of application of ultraviolet ray sterilization, radiation sterilization and ozone sterilization are reported. In the mechanism of these methods, the action to DNA and oxidation are common. (K.I.)

  10. Effects of Sterilization Cycles on PEEK for Medical Device Application.

    Science.gov (United States)

    Kumar, Amit; Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-02-21

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed.

  11. Electric dipole moments of charged leptons with sterile fermions

    International Nuclear Information System (INIS)

    Abada, Asmaa; Toma, Takashi

    2016-01-01

    We address the impact of sterile fermions on charged lepton electric dipole moments. Any experimental signal of these observables calls for scenarios of physics beyond the Standard Model providing new sources of CP violation. In this work, we consider a minimal extension of the Standard Model via the addition of sterile fermions which mix with active neutrinos and we derive the corresponding analytical expressions for the electric dipole moments of charged leptons at two-loop order. Our study reveals that, in order to have a non-vanishing contribution in this framework, the minimal extension necessitates the addition of at least 2 sterile fermion states to the Standard Model field content. Our conclusion is that sterile neutrinos can give significant contributions to the charged lepton electric dipole moments, some of them lying within present and future experimental sensitivity if the masses of the non-degenerate sterile states are both above the electroweak scale. The Majorana nature of neutrinos is also important in order to allow for significative contributions to the charged lepton electric dipole moments. In our analysis we impose all available experimental and observational constraints on sterile neutrinos and we further discuss the prospect of probing this scenario at low and high energy experiments.

  12. Electric dipole moments of charged leptons with sterile fermions

    Energy Technology Data Exchange (ETDEWEB)

    Abada, Asmaa; Toma, Takashi [Laboratoire de Physique Théorique, CNRS, University Paris-Sud, Université Paris-Saclay, 91405 Orsay (France)

    2016-02-26

    We address the impact of sterile fermions on charged lepton electric dipole moments. Any experimental signal of these observables calls for scenarios of physics beyond the Standard Model providing new sources of CP violation. In this work, we consider a minimal extension of the Standard Model via the addition of sterile fermions which mix with active neutrinos and we derive the corresponding analytical expressions for the electric dipole moments of charged leptons at two-loop order. Our study reveals that, in order to have a non-vanishing contribution in this framework, the minimal extension necessitates the addition of at least 2 sterile fermion states to the Standard Model field content. Our conclusion is that sterile neutrinos can give significant contributions to the charged lepton electric dipole moments, some of them lying within present and future experimental sensitivity if the masses of the non-degenerate sterile states are both above the electroweak scale. The Majorana nature of neutrinos is also important in order to allow for significative contributions to the charged lepton electric dipole moments. In our analysis we impose all available experimental and observational constraints on sterile neutrinos and we further discuss the prospect of probing this scenario at low and high energy experiments.

  13. Radiating sterilization of the venom of snake

    International Nuclear Information System (INIS)

    Abiyev, H.A.; Topchiyeva, Sh.A.; Rustamov, V.R.

    2006-01-01

    Full text: Water solutions of venoms are unstable and they lose toxicity in some day. Snake venoms inactivate under action of some physical factors: the UV-irradiation, x-rays beams. The purpose of the present work was sterilization of venom Vipera lebetina obtusa under influence of small dozes γ-radiations. Object of research was integral venom of adult individuals. Transcaucasian viper, and also the water solutions of venom irradiated with small dozes scale of radiation. An irradiation of venom carried out to radioisotope installation 60NI. For experiment tests of dry venom, and also their water solutions have been taken. Water solutions of venom have been subjected -radiation up to dozes 1.35, 2.7, 4.05, 5.4 kGr simultaneously dry venom of vipers was exposed -radiation before absorption of a doze 5.4 kGr. In comparative aspect action scale of radiation on ultra-violet spectra of absorption of venom was studied. Ultra-violet spectra venom have been taken off on device Specord UV-VIS. In 12 months after an irradiation spectra of absorption of venom have been repeatedly taken off. In spectra irradiated dry and solutions of venom new maxima of absorption have been revealed in the field of 285 nm and 800 nm describing change of toxicity. It is shown, that the increase in absorption of a doze of radiation occurs decrease of intensity of strips of absorption reduction of intensity of absorption.It is revealed at 260 and 300 nm testifying to course of biochemical reactions of separate enzymes zootoxins. It is necessary to note, that at comparison of intensity of absorption of control samples of poison with irradiated up to dozes 1.35 kGr it has not been revealed essential changes. The subsequent increase in a doze scale of radiation up to 2.7, 4.05, 5.4 kGr promotes proportional reduction of intensity of the absorption, describing toxicity of snake venom. At repeated (later 12 months) measurement of the irradiated water solutions of venom are not revealed changes in

  14. Radiation sterilization of harmful algae in water

    International Nuclear Information System (INIS)

    Byung Chull An; Jae-Sung Kim; Seung Sik Lee; Shyamkumar Barampuram; Eun Mi Lee; Byung Yeoup Chung

    2007-01-01

    Complete text of publication follows. Objective: Drinking water, water used in food production and for irrigation, water for fish farming, waste water, surface water, and recreational water have been recently recognized as a vector for the transmission of harmful micro-organisms. The human and animal harmful algae is a waterborne risk to public health and economy because the algae are ubiquitous and persistent in water and wastewater, not completely removed by physical-chemical treatment processes, and relatively resistant to chemical disinfection. Gamma and electron beam radiation technology is of growing in the water industry since it was demonstrated that gamma and electron beam radiation is very effective against harmful algae. Materials and Methods: Harmful algae (Scenedesmus quadricauda(Turpin) Brebisson 1835 (AG10003), Chlorella vulgaris Beijerinck 1896 (AG30007) and Chlamydomonas sp. (AG10061)) were distributed from Korean collection for type cultures (KCTC). Strains were cultured aerobically in Allen's medium at 25□ and 300 umol/m2s for 1 week using bioreactor. We investigated the disinfection efficiency of harmful algae irradiated with gamma (0.05 to 10 kGy for 30 min) and electron beam (1 to 19 kGy for 5 sec) rays. Results and Conclusion: We investigated the disinfection efficiency of harmful algae irradiated with gamma and electron beam rays of 50 to 19000 Gy. We established the optimum sterilization condition which use the gamma and electron beam radiation. Gamma ray disinfected harmful algae at 400 Gy for 30 min. Also, electron beam disinfected at 1000 Gy for 5 sec. This alternative disinfection practice had powerful disinfection efficiency. Hence, the multi-barrier approach for drinking water treatment in which a combination of various disinfectants and filtration technologies are applied for removal and inactivation of different microbial pathogens will guarantee a lower risk of microbial contamination.

  15. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: An in vitro study

    Directory of Open Access Journals (Sweden)

    Venkatasubramanian R

    2010-03-01

    Full Text Available Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  16. Reliability of Laparoscopic Compared With Hysteroscopic Sterilization at One Year: A Decision Analysis

    Science.gov (United States)

    Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.

    2011-01-01

    OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842

  17. Prospects for radiation sterilization of medical products in Egypt

    International Nuclear Information System (INIS)

    Roushdy, H.M.

    1975-01-01

    The pharmaceutical industry in Egypt is continually expanding its activity and each year marks new accomplishments and additions which enable the companies to apply the most modern scientific means in the production of pharmaceutical preparations and consequently to improve their market potentialities. The certainty of expansion and the possibility of increasing exports of sterilized medical products, particularly to Arab and African countries, indicate a need for a gamma-sterilization plant. This technology permits the introduction of the latest practices with regard to used disposables, thus greatly reducing the chances of cross-contamination which usually results in serious complications enhanced by local environmental conditions. This paper reviews the current state and future prospects for radiation sterilization of medical products and biological tissues in connection with other related industrial radiation processings. Moreover, the paper reviews the Egyptian scientific and technical experience with irradiation facilities and the parameters underlying the choice of Egypt's first industrial gamma and electron-beam irradiators designed for more than a single-purpose use, with hygienic measures taken to avoid biological contamination of sterilized medical packages throughout the sterilization process. In addition, the paper deals with the policy set up for establishing the Egyptian National Centre for Radiation Technology with a view to introducing irradiation techniques in the sterilization of medical products, and to improving the properties and increasing the competitiveness of Egyptian fabrics. Apart from medical sterilization, certain industrial processes have been mentioned to show how a multi-purpose irradiation facility may be utilized in a developing country to justify significantly the large investment required. (author)

  18. Multiple matings among glossina and the sterile male technique

    International Nuclear Information System (INIS)

    Pinhao, R.C.

    1980-01-01

    The fact that multiple matings are a common phenomenon among glossina turns the sterile male technique into a competition not between adult insects but between two types of sperm, and the proportion of females inseminated with the one or the other is given by the binomial (p+q)sup(n), where p is the percentage of normal males, q the percentage of sterile males and n the average number of matings per female. However, multiple matings cannot damage the effectiveness of the technique unless two conditions are present either separately or simultaneously: precocious death of the spermatozoa and reduced inseminating potential among the sterile males. Study of the factors which can alter the inseminating potential is thus important for those who wish to use the sterile male technique. These factors are of three kinds: factors connected with quality, with quantity and with availability. The first are associated with the nature and intensity of the alterations brought about in the spermatozoa by the sterilizing agent, the second with possible variations in the amount of sperm reaching the spermotheca, the third with the behaviour of the sterile males in the nature - that is, the question whether sterilization has a favourable or unfavourable influence on their chances of mating with wild females. The author describes his observations of the quantity of sperm produced by Glossina morsitans submorsitans males from the colony reared at the Institute for Tropical Hygiene and Medicine in Lisbon, compares them with the observations of other authors and discusses their practical significance. Specific research is suggested. Advantages from assessing the behaviour of colonies not by female productivity but by male inseminating potential, and appropriate laboratory techniques

  19. Segregation of male-sterility alleles across a species boundary.

    Science.gov (United States)

    Weller, S G; Sakai, A K; Culley, T M; Duong, L; Danielson, R E

    2014-02-01

    Hybrid zones may serve as bridges permitting gene flow between species, including alleles influencing the evolution of breeding systems. Using greenhouse crosses, we assessed the likelihood that a hybrid zone could serve as a conduit for transfer of nuclear male-sterility alleles between a gynodioecious species and a hermaphroditic species with very rare females in some populations. Segregation patterns in progeny of crosses between rare females of hermaphroditic Schiedea menziesii and hermaphroditic plants of gynodioecious Schiedea salicaria heterozygous at the male-sterility locus, and between female S. salicaria and hermaphroditic plants from the hybrid zone, were used to determine whether male-sterility was controlled at the same locus in the parental species and the hybrid zone. Segregations of females and hermaphrodites in approximately equal ratios from many of the crosses indicate that the same nuclear male-sterility allele occurs in the parent species and the hybrid zone. These rare male-sterility alleles in S. menziesii may result from gene flow from S. salicaria through the hybrid zone, presumably facilitated by wind pollination in S. salicaria. Alternatively, rare male-sterility alleles might result from a reversal from gynodioecy to hermaphroditism in S. menziesii, or possibly de novo evolution of male sterility. Phylogenetic analysis indicates that some species of Schiedea have probably evolved separate sexes independently, but not in the lineage containing S. salicaria and S. menziesii. High levels of selfing and expression of strong inbreeding depression in S. menziesii, which together should favour females in populations, argue against a reversal from gynodioecy to hermaphroditism in S. menziesii. © 2014 The Authors. Journal of Evolutionary Biology © 2014 European Society For Evolutionary Biology.

  20. Temperature Effects on Free Radicals in Gamma-sterilized Beef

    Science.gov (United States)

    Pramanik, S. I.; Jahan, M. S.

    1999-11-01

    Gamma irradiation has become the method of choice for sterilizing frozen meat and their products to reduce levels of food-borne pathogens and to extend shelf life. In this report we have employed ESR technique for detection of free radicals in sterilized and non-sterilized dry beef without bone. We have also determined the heating effects on free radicals at temperatures 176^°C and 250^°C. Meat samples were dried in a food dehydrator at 60^°C and were packaged in dry N_2. They were then sterilized by γ-irradiation (2.5 MRad), ground into powder, and placed in ESR sample tubes. Non-sterilized powder samples were used as control. While all powder samples, sterilized or not, produced a broad single line in the ESR spectra with (Δ H_pp ~ 9 G) and g = 2.013, the radical concentration in the sterilized samples increased by a factor of five. Heat treatment at 176^°C produced similar radicals. But, when samples were heated 250^°C different radical species were formed which are characterized by narrow width (Δ H_pp ~ 6 G) and lower g-value (g =2.010). In contrast with previous work, where free radicals in chicken bones were reduced by heating [1], we observed an increase in concentration. Results of structural analyses of the radicals will be presented. Ref.[1]: Radiat. Phys. Chem., 49, 477-481, 1997. Work supported by Grants from the University of Memphis

  1. [Preliminary Study of Lonicera hypoglauca on Germination Conditions of Sand Culture Seeds and Sterilization Method of Sand Culture Seedling Sterilization].

    Science.gov (United States)

    Tan, Mu-xiu; Zeng, Wen-wen; Wei, Peng-xiao; Mo, Qiao-cheng; Pu, Zu-ning; Cen, Xiu-fen; Shi, Feng-hua

    2015-05-01

    To explore the germination conditions of Lonicera hypoglauca sand culture seeds and the effects of sand culture seedlings sterilization. 0.1% HgCl2 with different sterilization time, different illumination time and temperature culture condition were adopted to study the germination conditions of sand culture seeds. Different sterilization treatments and different hardening-seedling days were used to test the sterilization effect of sand culture seedlings. The sterilization effect of the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min on Lonicera hypoglauca seeds was the optimum,with the average pollution rate of 15.56%, and the average germination rate reached 51.11%. The combination of varied temperature-room temperature under light for 12 h/d was the best, with the average germination rate peaked at 75.49%, and the average germination potential reached 68.36%. The treatment of detergent liquor scrub-tap water wash on the part above the hypocotyl, which was sand cultured under the opening condition and had no root, showed the best sterilization effect, with the average pollution rate was zero, and the average survival rate peaked at 100.00%. The sterilization effect of sand culture seedlings, which was disinfected after cleaning by detergent liquor scrub-tap water wash after hardening-seeding for 30 days, was the best, with the average pollution rate of 50.00%, and the average survival rate of 100.00%. The best sterilization effect is the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min; Lighting for 12 h/d of varied temperature-room temperature is regarded as the optimum culture condition. The treatment of detergent liquor scrub-tap water wash treatment on the part above the hypocotyl,which is sand cultured under the opening condition and had no root, shows the best sterilization effect. For the sand culture seedlings, before inoculated in subculture medium, should be hardening-seedling for some days and sterilized after detergent liquor scrub-tap water wash.

  2. Vasectomy occlusion techniques for male sterilization.

    Science.gov (United States)

    Cook, L A; Vliet, H; Pun, A; Gallo, M F

    2004-01-01

    Vasectomy is an increasingly popular and effective family planning method. A variety of vasectomy techniques are used worldwide including various vas occlusion techniques (excision and ligation, thermal or electrocautery, and mechanical and chemical occlusion methods), vas irrigation and fascial interposition. Vasectomy guidelines largely rely on information from observational studies. Ideally, the choice of vasectomy techniques should be based on the best available evidence from randomized controlled trials. The objective of this review was to compare the effectiveness, safety, acceptability and costs of vasectomy techniques for male sterilization. We searched the computerized databases the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Popline and LILACS. In addition, we searched the reference lists of relevant articles and book chapters. We included randomized controlled trials and controlled clinical trials comparing vasectomy techniques. We assessed all titles and abstracts located in the literature searches and two reviewers independently extracted articles identified for inclusion. Data were presented in the text of the review. Outcome measures include contraceptive efficacy, safety, discontinuation, and acceptability. Two trials compared vas occlusion with clips versus a conventional vasectomy technique; both were of poor quality. Neither trial found a difference between the two groups with regard to the primary outcome of failure to reach azoospermia. Four trials examined vas irrigation: three compared water irrigation with no irrigation and one compared water irrigation with euflavine. All of the trials were of poor quality. None of the trials found a significant difference between the groups with respect to the primary outcome of time to azoospermia. However, one trial found that the median number of ejaculations to azoospermia was significantly lower in the euflavine group compared to the water irrigation group. The one trial

  3. Application of electron beam radiation for peat sterilization and suppression of microbe contaminants

    International Nuclear Information System (INIS)

    Tsai, David

    2006-01-01

    Inoculation of root nodule bacteria into legume seeds such as soybean [Glycine max. (L.)], common bean (Phaseolus vulgaris L.) and forage pasture has been effective and convenient as this simple procedure may introduce effective strains of Bradyrhizobium/Rhizobium into agricultural soils without a past history of successful cropping systems with the legume hosts. Peat-based substrates previously sterilized have been used for decades as bacteria carrier, protecting them from the prevailing harsh conditions in tropical soils and ensuring their survival with nutrient and protection against the soil antagonists. The Brazilian Government requires that all peat-based substrates must be gamma-sterilized from a cobalt-60 ( 60 Co) source, prior the introduction of the root nodule bacteria into the package. The recommendation is for a dose up to 50 kGy for an effective suppression of pathogens and saprophytes, in order to avoid competition among the substrate microbiota. Recently, the use of the electron beam (EB) accelerator has shown to be a new alternative for peat pre-sterilization, as this technique may promote reactive free-radicals which are efficient to suppress microbial contaminants. This fast technology is considered more environment and ecology friendly-sound than gamma radiation (γ). The disadvantage of not reaching higher depth than gamma rays from 60 Co must be considered, and attempts of optimizing the technique are crucial. This study compared both methods by using increasing rates of radiation by 60 Co by the EB method - O, 10, 20, 30, 40 e 50 kGy in a commercial peat used for inoculants. Experimental data from days 7, 14, 21 and 28 days (growth period) and 150, 180 and 210 days (storage period) indicated high numbers of the strain Rhizobium tropici CM-01, labelled with gusA + (Study 1) and celB + (Study 2) from both eat-sterilizing techniques, reaching values above the minimum of 1x10 8 cells g -1 peat. At high rates, above 40 kGy, and after long

  4. A preliminary evaluation of a reusable digital sterilization indicator prototype.

    Science.gov (United States)

    Puttaiah, R; Griggs, J; D'Onofrio, M

    2014-09-01

    Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of sterilizers. Data loggers or independent digital parametric indicators are innovative devices that provide more information than various classes chemical indicators. In this study we evaluated a prototype of an independent digital parametric indicator's use in autoclaves. The purpose of this study was to evaluate the performance of an independent digital indicator/data logger prototype (DS1922F) that could be used for multiple cycles within an autoclave.MG Materials and methods: Three batches of the DS1922F (150 samples) were used in this study that was conducted in a series. The first batch was challenged with 300 sterilization cycles within an autoclave and the data loggers evaluated to study failures and the reason for failure, make corrections and improve the prototype design. After changes made based on studying the first batch, the second batch of the prototype (150 samples) were challenged once again with 300 sterilization cycles within an autoclave and failure studied again in further improvement of the prototype. The final batch (3rd batch) of the prototype (150 samples) was challenged again but with 600 cycles to see how long they would last. Kaplan-Meier survival analysis analyses of all three batches was conducted (α = 0.05) and failed samples qualitatively studied in understanding the variables involved in the failure of the prototype, and in improving quality. Each tested batch provided crucial information on device failure and helped in improvement of the prototype. Mean lifetime survival of the final batch (Batch 3) of prototype was 498 (480, 516) sterilization cycles

  5. Dark radiation sterile neutrino candidates after Planck data

    Energy Technology Data Exchange (ETDEWEB)

    Valentino, Eleonora Di; Melchiorri, Alessandro [Physics Department and INFN, Università di Roma ' ' La Sapienza' ' , Ple Aldo Moro 2, 00185, Rome (Italy); Mena, Olga, E-mail: eleonora.divalentino@roma1.infn.it, E-mail: alessandro.melchiorri@roma1.infn.it, E-mail: omena@ific.uv.es [IFIC, Universidad de Valencia-CSIC, 46071, Valencia (Spain)

    2013-11-01

    Recent Cosmic Microwave Background (CMB) results from the Planck satellite, combined with previous CMB data and Hubble constant measurements from the Hubble Space Telescope, provide a constraint on the effective number of relativistic degrees of freedom 3.62{sup +0.50}{sub −0.48} at 95% CL. New Planck data provide a unique opportunity to place limits on models containing relativistic species at the decoupling epoch. We present here the bounds on sterile neutrino models combining Planck data with galaxy clustering information. Assuming N{sub eff} active plus sterile massive neutrino species, in the case of a Planck+WP+HighL+HST analysis we find m{sub ν,} {sub sterile}{sup eff} < 0.36 eV and 3.14 < N{sub eff} < 4.15 at 95% CL, while using Planck+WP+HighL data in combination with the full shape of the galaxy power spectrum from the Baryon Oscillation Spectroscopic Survey BOSS Data Relase 9 measurements, we find that 3.30 < N{sub eff} < 4.43 and m{sub ν,} {sub sterile}{sup eff} < 0.33 eV both at 95% CL with the three active neutrinos having the minimum mass allowed in the normal hierarchy scheme, i.e. ∑m{sub ν} ∼ 0.06 eV. These values compromise the viability of the (3+2) massive sterile neutrino models for the parameter region indicated by global fits of neutrino oscillation data. Within the (3+1) massive sterile neutrino scenario, we find m{sub ν,} {sub sterile}{sup eff} < 0.34 eV at 95% CL. While the existence of one extra sterile massive neutrino state is compatible with current oscillation data, the values for the sterile neutrino mass preferred by oscillation analyses are significantly higher than the current cosmological bound. We review as well the bounds on extended dark sectors with additional light species based on the latest Planck CMB observations.

  6. Radiation protection aspects of dismantling and decommissioning of Uranium Mining of Andujar (Spain)

    International Nuclear Information System (INIS)

    Ortiz Ramis, M.T.; Garcia-Bermejo Fernandez, R.; Martin Palomo, N.

    1995-01-01

    This study analyzes the radiation protection aspects during the decommissioning and dismantling of uranium mining in Andujar (Spain). The application during dismantling's mining, the transfer factor of natural radioactive isotopes and the application during the sterile movements are presented

  7. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  8. Sterilization of microbes by using various plasma jets

    Energy Technology Data Exchange (ETDEWEB)

    Uhm, Han S.; Choi, Eun H.; Cho, Guang S. [Kwangwoon University, Seoul (Korea, Republic of); Hong, Yong C. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2012-03-15

    Sterilization of various microbes was carried out by using several plasma jets. Argon plasma jets penetrate deep into ambient air and create a path for oxygen radicals to sterilize microbes including spores. A sterilization experiment with bacterial endospores indicates that an argon-oxygen plasma jet very effectively kills endospores of Bacillus atrophaeus (ATCC 9372), thereby demonstrating its capability to clean surfaces and its usefulness for reinstating contaminated equipment as free from toxic biological agents. The key element of the sterilization is oxygen radicals. The penciltype configuration produces a long, cold plasma jet capable of reaching 3.5 cm and having various excited plasma species shown through the optical emission spectrum. Operation of an air plasma jet at 2 W in a pencil-type electrode provides an excellent opportunity for sterilization of microbes. An electron microscope was used to observe the effects of the plasma on bacterial cell morphology. Transmission electron micrographs showed morphological changes in E. coli cells treated with an atmospheric plasma at 75 W for 2 min. The treated cells had severe cytoplasmic deformations and leakage of bacterial chromosome. The chromosomal DNA was either attached to the bacterial cells or released freely into the surrounding medium. The results clearly explain the loss of viability of bacterial cells after plasma treatment.

  9. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    International Nuclear Information System (INIS)

    Huang, Junting

    2015-01-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states v e , v μ and v τ . In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ 24 in the range of 10 -2 eV 2 < Δm 43 2 < 1 eV 2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  10. In vitro sterilization technique on embryo of black Toraja rice

    Science.gov (United States)

    Haring, F.; Riadi, M.; Rafiuddin; Sjahril, R.; Muchlis, A. R.

    2018-05-01

    Toraja black rice has a high anthocyanin content, a water-soluble pigments, with antioxidant activity. Toraja black rice has a variety of seeds colour in one panicles such as full black (the outside and inside the rice), medium black (the outside and slightly inside rice) and a little black (only the outside of rice). Embryo culture in vitro is one way to grow plants in sterile conditions. The presence of contamination and the death of the embryo require in vitro embryo culture. The sterilization technique is a very important first step to eliminate contamination and the death of embryos. This research aims to determine the right material composition for sterilization of black rice’s embryo. The experiment was done by growing black rice on half strength MS media with the treatment of three method of sterilization, i.e.: S1 (70% alcohol for 5 minutes, 3% and 2% Chlorox each for 10 minutes,), S2 (70% alcohol for 3 minutes, 2% Clorox for 10 minutes) and S3 (70% alcohol for 3 minutes and 1% Clorox for 15 minutes). The materials used are rice seedlings that have been cut in two and opened the pericarp of paddy grain, leaving a piece of rice that has a complete embryo. The best sterilization for Toraja black rice embryo culture was using the S3 composition. Best germination was seen on the seeds with full and medium black color.

  11. Electron beam sterilization of water discharged from sewage

    International Nuclear Information System (INIS)

    Miyata, Teijiro; Arai, Hidehiko; Tokunaga, Okihiro; Machi, Sueo; Kondo, Masaki; Minemura, Takashi; Nakao, Akio; Seike, Yasuhiko.

    1989-01-01

    At present, the water treated at city sewerages is discharged to rivers after the chlorine sterilization, but it was clarified recently that this chlorine treatment produces carcinogenic organic chlorine compounds, and residual chlorine exerts harmful effect to aquatics, therefore, it is desirable to develop the sterilization techniques substituting for chlorine treatment. Already many reports elucidated that irradiation is effective for the sterilization of the water discharged from sewerage. However, as the technical subject for putting radiation process in practical use, the treatment of large quantity was a problem. Recently by the progress of the technology of manufacturing electron accelerators, the equipment with large power output which can treat in large quantity was developed, and it has become applicable also to sewage treatment. Therefore, the authors examined the practicality of electron beam process as the substitute technology for chlorine sterilizaiton. In the case of using electron beam, though the power output of accelerators is large, the flight range of electron beam in water is short. The comparison of the sterilization effect of electron beam with that of Co-60 gamma ray, the effects of water depth, discharged water quality and water velocity on the sterilization effect and so on were experimentally examined. (K.I.)

  12. Search for heavy sterile neutrinos in trileptons at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Claudio O. [Univ. Tecnica Federico Santa Maria, Valparaiso (Chile). CCTVal y Dept. of Physics; Kim, C.S. [Yonsei Univ., Seoul (Korea, Republic of). Dept. of Physics and IPAP; Wang, Kechen [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Chinese Academy of Sciences, Beijing (China). Center for Future High Energy Physics

    2017-03-15

    We present a search strategy for both Dirac and Majorana sterile neutrinos from the purely leptonic decays of W{sup ±}→e{sup ±}e{sup ±}μ{sup -+}ν and μ{sup ±}μ{sup ±}e{sup -+}ν at the 14 TeV LHC. The discovery and exclusion limits for sterile neutrinos are shown using both the Cut-and-Count (CC) and Multi-Variate Analysis (MVA) methods. We also discriminate between Dirac and Majorana sterile neutrinos by exploiting a set of kinematic observables which differ between the Dirac and Majorana cases. We find that the MVA method, compared to the more common CC method, can greatly enhance the discovery and discrimination limits. Two benchmark points with sterile neutrino mass m{sub N}=20 GeV and 50 GeV are tested. For an integrated luminosity of 3000 fb{sup -1}, sterile neutrinos can be found with 5σ significance if heavy-to-light neutrino mixings vertical stroke U{sub Ne} vertical stroke {sup 2}∝ vertical stroke U{sub Nμ} vertical stroke {sup 2}∝10{sup -6}, while Majorana vs. Dirac discrimination can be reached if at least one of the mixings is of order 10{sup -5}.

  13. Population suppression in support of the sterile insect technique

    International Nuclear Information System (INIS)

    Mangan, R.L.

    2005-01-01

    Suppression or eradication of insect pest populations by the release of sterile insects is often dependent on supplementary methods of pest reduction to levels where the target pest population can be overflooded with sterile insects. Population suppression activities take place in advance of, or coincide with, the production of sterile insects. Supplementary methods to remove breeding opportunities, or management methods that prevent access of pests to the hosts, may reduce the population or prevent damage. Insecticides have been used widely in direct applications or applied as baits, in traps, or on specific sites where the pest makes contact or reproduces. As sterile insect release does not kill the pest, adult biting pests or fertile mated females of the pests will continue to attack hosts after the release of sterile insects. Thus supplementary pest suppression programmes and quarantine measures are essential to prevent damage or the spread of disease. Eradication or effective pest management requires that the entire population of the pest be treated, or that the programme apply immigration barriers. When supplementary pest control activities benefit the human population in areas being treated, such as in mosquito or screwworm eradication programmes, these activities are usually acceptable to the public, but when the public receives no direct benefit from supplementary control activities such as in fruit fly programmes, social resistance may develop. (author)

  14. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Junting [Univ. of Texas, Austin, TX (United States)

    2015-05-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states ve, vμ and vτ. In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ24 in the range of 10-2 eV2 < Δm412 < 1 eV2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  15. Search for heavy sterile neutrinos in trileptons at the LHC

    International Nuclear Information System (INIS)

    Dib, Claudio O.; Kim, C.S.; Wang, Kechen; Chinese Academy of Sciences, Beijing

    2017-03-01

    We present a search strategy for both Dirac and Majorana sterile neutrinos from the purely leptonic decays of W"±→e"±e"±μ"-"+ν and μ"±μ"±e"-"+ν at the 14 TeV LHC. The discovery and exclusion limits for sterile neutrinos are shown using both the Cut-and-Count (CC) and Multi-Variate Analysis (MVA) methods. We also discriminate between Dirac and Majorana sterile neutrinos by exploiting a set of kinematic observables which differ between the Dirac and Majorana cases. We find that the MVA method, compared to the more common CC method, can greatly enhance the discovery and discrimination limits. Two benchmark points with sterile neutrino mass m_N=20 GeV and 50 GeV are tested. For an integrated luminosity of 3000 fb"-"1, sterile neutrinos can be found with 5σ significance if heavy-to-light neutrino mixings vertical stroke U_N_e vertical stroke "2∝ vertical stroke U_N_μ vertical stroke "2∝10"-"6, while Majorana vs. Dirac discrimination can be reached if at least one of the mixings is of order 10"-"5.

  16. Benchmarking of Sterilizing grade filters with liposome Filtration.

    Science.gov (United States)

    Loewe, Thomas; Mundlamuri, Ramesh; Loewe, Thomas; Mundrigi, Ashok; Handt, Sebastian; Singh, Bhuwan

    2017-12-14

    Cytotoxic drugs can be encapsulated in liposomes vesicles, which act as drug delivery vehicles and reduce the risk of exposure of drug to healthy cells(1). The sterility of such liposome solutions is typically ensured using 0.2μm rated sterilizing grade membranes, but due to the high viscosity and low surface tension of these formulations, they can cause pre-mature blocking and increased risk of bacterial penetration through a 0.2μm sterilizing grade membrane(2). The low surface tension of liposome solutions affects the contact angle with membrane and reduces bubble point leading to bacterial penetration through the membrane. This poses a great challenge to select an appropriate sterilizing grade membrane for a given process and for filter manufacturers to develop a sterilizing grade membrane that specifically addresses these needs. In this study, the influence of different variables that could affect the total throughput and bacterial retention performance of different membranes types on processing of liposome solutions have been evaluated. Based on the results, we conclude that the membrane properties e.g., surface porosity, surface tension, pore size, symmetry/asymmetry, hydrophilicity and liposome properties e.g., composition, lipid size and concentration affect bacterial retention and total throughput capacity. Process parameters such as temperature, pressure and flow should also be optimized to improve process efficiency. Copyright © 2017, Parenteral Drug Association.

  17. Effects of sterile neutrino and extra-dimension on big bang nucleosynthesis

    Science.gov (United States)

    Jang, Dukjae; Kusakabe, Motohiko; Cheoun, Myung-Ki

    2018-04-01

    We study effects of the sterile neutrino in the five-dimensional universe on the big bang nucleosynthesis (BBN). Since the five-dimensional universe model leads to an additional term in the Friedmann equation and the energy density of the sterile neutrino increases the total energy density, this model can affect the primordial abundance via changing the cosmic expansion rate. The energy density of the sterile neutrino can be determined by a rate equation for production of the sterile neutrino. We show that not only the mixing angle and the mass of the sterile neutrino, but also a resonant effect in the oscillation between sterile and active neutrinos is important to determine a relic abundance of the sterile neutrino. In this study, we also investigate how the sterile neutrino in extra-dimensional model can affect the BBN, and constrain the parameters related to the above properties of the sterile neutrino by using the observational primordial abundances of light elements.

  18. Estimation of populations and sterility induction in Anastrepha ludens (Diptera: Tephritidae) fruit flies

    International Nuclear Information System (INIS)

    Flores, Salvador; Montoya, Pablo; Toledo, Jorge; Liedo, Pablo; Enkerlin, Walther

    2015-01-01

    The relationship between different release densities of sterile flies and fly trap captures, expressed as flies per trap per day, in the monitoring of Anastrepha ludens (Loew) populations was evaluated in mango orchards. The induction of sterility in fertile females was evaluated using different ratios of sterile: fertile males under field cage conditions. A direct relationship between recaptured flies and densities of release sterile flies was found. However, trap efficiency, expressed as percentage of recaptured flies, decreased as the density of released flies increased. Sterility induction was positively correlated to the ratio of sterile: fertile flies. A significant difference in egg fertility among treatments was observed. The trajectory of sterility induction slowed down after a sterile: wild ratio of 30:1, which suggests that this ratio could be appropriate in an sterile insect technique program with A. ludens. Sterility induction was greater when only sterile males were released than when releasing both sterile males and females, but the differences were not significant. Our findings contribute to a better interpretation of fly captures obtained from the field trapping networks, and to an improvement in the efficiency of sterile insect technique against A. ludens fruit flies, through the implementation of more rational sterile fly release densities. (author)

  19. Sterile neutrinos, lepton asymmetries, primordial elements: How much of each?

    International Nuclear Information System (INIS)

    Chu Yizen; Cirelli, Marco

    2006-01-01

    We investigate quantitatively the extent to which having a primordial leptonic asymmetry (n ν ≠n ν ) relaxes the bounds on light sterile neutrinos imposed by BBN and LSS. We adopt a few assumptions that allow us to solve the neutrino evolution equations over a broad range of mixing parameters and asymmetries. For the general cases of sterile mixing with the electron or muon neutrino, we identify the regions that can be reopened. For the particular case of a LSND-like sterile neutrino, soon to be rejected or confirmed by MiniBooNE, we find that an asymmetry of the order of 10 -4 is needed to lift the conflicts with cosmology

  20. Displaced vertex searches for sterile neutrinos at future lepton colliders

    Energy Technology Data Exchange (ETDEWEB)

    Antusch, Stefan [Department of Physics, University of Basel, Klingelbergstr. 82, CH-4056 Basel (Switzerland); Max-Planck-Institut für Physik (Werner-Heisenberg-Institut),Föhringer Ring 6, D-80805 München (Germany); Cazzato, Eros; Fischer, Oliver [Department of Physics, University of Basel, Klingelbergstr. 82, CH-4056 Basel (Switzerland)

    2016-12-02

    We investigate the sensitivity of future lepton colliders to displaced vertices from the decays of long-lived heavy (almost sterile) neutrinos with electroweak scale masses and detectable time of flight. As future lepton colliders we consider the FCC-ee, the CEPC, and the ILC, searching at the Z-pole and at the center-of-mass energies of 240, 350 and 500 GeV. For a realistic discussion of the detector response to the displaced vertex signal and the Standard Model background we consider the ILC’s Silicon Detector (SiD) as benchmark for the future lepton collider detectors. We find that displaced vertices constitute a powerful search channel for sterile neutrinos, sensitive to squared active-sterile mixing angles as small as 10{sup −11}.

  1. Sterile neutrino search with the Double Chooz experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hellwig, Denise; Bekman, Ilja; Kampmann, Philipp; Schoppmann, Stefan; Soiron, Michael; Stahl, Achim; Wiebusch, Christopher [III. Physikalisches Institut B, RWTH Aachen (Germany)

    2016-07-01

    The Double Chooz experiment is a reactor neutrino disappearance experiment located at the Chooz nuclear power plant, France. It measures the electron-antineutrino flux of the two nuclear reactors with two detectors of identical design. A far detector at a distance of about 1 km is operating since 2011; a near detector at a distance of about 400 m is operating since the end of 2014. The combination of the two detectors offers sensitivity to sterile neutrino mixing parameters. Sterile neutrinos are neutrino mass states not taking part in weak interactions, but may mix with known neutrino states. This induces additional mixing angles and mass differences. This talk describes the search for sterile neutrinos and the sensitivity of Double Chooz to the mixing angle θ{sub 14}.

  2. Histopathologic changes in fallopian tubes subsequent to sterilization procedures.

    Science.gov (United States)

    Stock, R J

    1983-01-01

    Longitudinal serial and serial step sections of fallopian tubes from more than 100 patients, subsequent to tubal sterilization procedures, were examined. Thirteen of these patients had pregnancies following their sterilizations. The histologic findings at the previous surgical sites were compatible with what would be expected for a normal healing process. Evidence for a unique tubal epithelial process, as suggested by the terms "endosalpingiosis" or "recanalization," was lacking. Likewise, the author found no evidence of tuboperitoneal fistula formation and/or the subsequent occurrence of pregnancy secondary to localized endometriosis. The histologic notations of proximal luminal dilatation, plical attenuation, chronic inflammatory infiltrates with pseudopolyp formation, and the findings of plical thickening in the distal segment of remaining tube after an interruption type of procedure seem to be associated with the length of time from the sterilization procedure. These may be factors related to the apparent reduced success rate, with time, of microsurgical reanastomotic procedures.

  3. Toxicity of methods of implant material sterilization on corneal endothelium

    Energy Technology Data Exchange (ETDEWEB)

    Singh, G.; Boehnke, Mv.; von Domarus, D.; Draeger, J.

    1985-11-01

    The toxicity of different procedures utilized for the sterilization of intraocular implant material was assessed on the endothelium of organ-cultured porcine corneas. Polymethylmethacrylate lenses sterilized by treatment with sodium hydroxide (NaOH), ethylene oxide, formaldehyde, and gamma radiation were added to a culture medium containing normal porcine corneas. Considering the viability of endothelial cells, appearance of intracellular degenerative vacuoles, and denudation of corneal Descemet's membrane as criterion for the evaluation of toxicity of different methods of sterilization, the NaOH-treated lenses were found to be the least toxic to porcine corneal endothelium. Phase-contrast microscopy and vital staining of the endothelium permitted direct viewing of the endothelium aiding in the assessment of toxicity.

  4. Improved determination of sterile neutrino dark matter spectrum

    International Nuclear Information System (INIS)

    Ghiglieri, J.; Laine, M.

    2015-01-01

    The putative recent indication of an unidentified 3.55 keV X-ray line in certain astrophysical sources is taken as a motivation for an improved theoretical computation of the cosmological abundance of 7.1 keV sterile neutrinos. If the line is interpreted as resulting from the decay of Warm Dark Matter, the mass and mixing angle of the sterile neutrino are known. Our computation then permits for a determination of the lepton asymmetry that is needed for producing the correct abundance via the Shi-Fuller mechanism, as well as for an estimate of the non-equilibrium spectrum of the sterile neutrinos. The latter plays a role in structure formation simulations. Results are presented for different flavour structures of the neutrino Yukawa couplings and for different types of pre-existing lepton asymmetries, accounting properly for the charge neutrality of the plasma and incorporating approximately hadronic contributions.

  5. Sterilization of Turmeric by Atmospheric Pressure Dielectric Barrier Discharge Plasma

    International Nuclear Information System (INIS)

    Salarieh Setareh; Dorranian Davoud

    2013-01-01

    In this study atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed for sterilizing dry turmeric powders. A 6 kV, 6 kHz frequency generator was used to generate plasma with Ar, Ar/O 2 , He, and He/O 2 gases between the 5 mm gap of two quartz covered electrodes. The complete sterilization time of samples due to plasma treatment was measured. The most important contaminant of turmeric is bacillus subtilis. The results show that the shortest sterilization time of 15 min is achieved by exposing the samples to Ar/O 2 plasma. Survival curves of samples are exponential functions of time and the addition of oxygen to plasma leads to a significant increase of the absolute value of time constant of the curves. Magnitudes of protein and DNA in treated samples were increased to a similar value for all samples. Taste, color, and solubility of samples were not changed after the plasma treatment

  6. Sterilization of Turmeric by Atmospheric Pressure Dielectric Barrier Discharge Plasma

    Science.gov (United States)

    Setareh, Salarieh; Davoud, Dorranian

    2013-11-01

    In this study atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed for sterilizing dry turmeric powders. A 6 kV, 6 kHz frequency generator was used to generate plasma with Ar, Ar/O2, He, and He/O2 gases between the 5 mm gap of two quartz covered electrodes. The complete sterilization time of samples due to plasma treatment was measured. The most important contaminant of turmeric is bacillus subtilis. The results show that the shortest sterilization time of 15 min is achieved by exposing the samples to Ar/O2 plasma. Survival curves of samples are exponential functions of time and the addition of oxygen to plasma leads to a significant increase of the absolute value of time constant of the curves. Magnitudes of protein and DNA in treated samples were increased to a similar value for all samples. Taste, color, and solubility of samples were not changed after the plasma treatment.

  7. The nutritonal value of protein in radiation sterilized fish meal

    International Nuclear Information System (INIS)

    Harmuth-Hoene, A.E.; Partmann, W.

    1976-01-01

    Investigations of four samples of fish flour from various countries which had been sterilized by radiation (5 Mrad) did not show any evidence of radiation-induced changes in crude protein content as well as protein digestibility by enzymatic hydrolysis. Of the 16 amino acids studied only serine suffered a mean loss of 16% while the remaining amino acids showed only slight changes after irradiation. In all four samples we noticed a mean loss of 9% in available lysine. The sterilization of fish flour by irradiation does not diminish the nutritional value of fish protein to any significant extent and, should be given preference over sterilization by heat which reduces the protein quality of fumigation by heat which leaves residues. (orig.) [de

  8. Searches for light sterile neutrinos with multitrack displaced vertices

    Science.gov (United States)

    Cottin, Giovanna; Helo, Juan Carlos; Hirsch, Martin

    2018-03-01

    We study discovery prospects for long-lived sterile neutrinos at the LHC with multitrack displaced vertices, with masses below the electroweak scale. We reinterpret current displaced vertex searches making use of publicly available, parametrized selection efficiencies for modeling the detector response to displaced vertices. We focus on the production of right-handed WR bosons and neutrinos N in a left-right symmetric model, and find poor sensitivity. After proposing a different trigger strategy (considering the prompt lepton accompanying the neutrino displaced vertex) and optimized cuts in the invariant mass and track multiplicity of the vertex, we find that the LHC with √{s }=13 TeV and 300 fb-1 is able to probe sterile neutrino masses between 10 GeV right-handed gauge boson mass of 2 TeV work joins other efforts in motivating dedicated experimental searches to target this low sterile neutrino mass region.

  9. Study on the sterilization of egg white powder by irradiation

    International Nuclear Information System (INIS)

    Fu Lixin; Meng Lifen; Zhao Xiaonan; Xu Dechun; Hu Shaoxin; Chen Changdong; Wang Zhidong

    2013-01-01

    The sterilizing effect, influence on main essential nutrient and sensory qualities of egg white powder treated with 60 Co γ-ray irradiation were studied. The microorganism index of egg white powder samples treated with 4 kGy irradiation could meet the government food sanitation standard, and the sterilization rate could reach 100%. The irradiation doses from 4 to 10 kGy had little influence on egg white powder protein, crude fiber and amino acidscontent, and the sensory quality such as color, luster, and scent changed little below 6 kGy irradiation. Considering the result of this study, the optimal irradiation dose for egg white powder sterilization was 4 to 6 kGy. (authors)

  10. Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2007-01-01

    This part of ISO 11135 describes requirements that, if met, will provide an ethylene oxide sterilization process intended to sterilize medical devices, which has appropriate microbicidal activity. Furthermore, compliance with the requirements ensures that this activity is both reliable and reproducible so that it can be predicted, with reasonable confidence, that there is a low level of probability of there being a viable microorganism present on product after sterilization. Specification of this probability is a matter for regulatory authorities and may vary from country to country. The paper provides information on scope, normative references, terms and definitions, quality management systems, sterilizing agent characterization, process and equipment characterization, product definition, process definition, validation, routine monitoring and control, product release from sterilization and maintaining process effectiveness followed by Annex A (Determination of lethal rate of the sterilization process - Biological indicator/bioburden approach), Annex B (Conservative determination of lethal rate of the sterilization process - Overkill approach, annex C (General guidance) and a bibliography.

  11. Contraception or eugenics? Sterilization and "mental retardation" in the 1970s and 1980s.

    Science.gov (United States)

    Ladd-Taylor, Molly

    2014-01-01

    Nonconsensual sterilization is usually seen as the by-product of a classist and racist society; disability is ignored. This article examines the 1973 sterilization of two young black girls from Alabama and other precedent-setting court cases involving the sterilization of "mentally retarded" white women to make disability more central to the historical analysis of sterilization. It analyzes the concept of mental retardation and the appeal of a surgical solution to birth control, assesses judicial deliberations over the "right to choose" contraceptive sterilization when the capacity to consent is in doubt, and reflects on the shadow of eugenics that hung over the sterilization debate in the 1970s and 1980s.

  12. Low temperature gamma sterilization of a bioresorbable polymer, PLGA

    Science.gov (United States)

    Davison, Lisa; Themistou, Efrosyni; Buchanan, Fraser; Cunningham, Eoin

    2018-02-01

    Medical devices destined for insertion into the body must be sterilised before implantation to prevent infection or other complications. Emerging biomaterials, for example bioresorbable polymers, can experience changes in their properties due to standard industrial sterilization processes. Gamma irradiation is one of the most reliable, large scale sterilization methods, however it can induce chain scission, cross-linking or oxidation reactions in polymers. sterilization at low temperature or in an inert atmosphere has been reported to reduce the negative effects of gamma irradiation. The aim of this study was to investigate the impact of low temperature sterilization (at -80 °C) when compared to sterilization at ambient temperature (25 °C) both in inert atmospheric conditions of nitrogen gas, on poly(lactide co-glycolide) (PLGA). PLGA was irradiated at -80 and 25 °C at 40 kGy in a nitrogen atmosphere. Samples were characterised using differential scanning calorimetry (DSC), tensile test, Fourier transform infrared (FTIR) spectroscopy, proton nuclear magnetic resonance (1H NMR) spectroscopy and gel permeation chromatography (GPC). The results showed that the molecular weight was significantly reduced as was the glass transition temperature, an indication of chain scission. FTIR showed small changes in chemical structure in the methyl and carbonyl groups after irradiation. Glass transition temperature was significantly different between irradiation at -80 °C and irradiation at 25 °C, however this was a difference of only 1 °C. Ultimately, the results indicate that the sterilization temperature used does not affect PLGA when carried out in a nitrogen atmosphere.

  13. The Rise of Female Sterilization: A Closer Look at Colombia.

    Science.gov (United States)

    Folch, Beatriz M; Betstadt, Sarah; Li, Dongmei; Whaley, Natalie

    2017-09-01

    Objective In the 1970s, OCPs and IUDs were the most popular contraceptive methods in Colombia. According to data from the most recent Demographic and Health Survey (DHS), sterilization has become the most common form of birth control in Colombia. This study aims to examine the characteristics of Colombian women desiring long-acting contraception. Methods This study uses the 2005 and 2010 Colombian DHS dataset. Women who choose long-acting contraception were divided into those using female sterilization and those using long-acting reversible contraception (LARC). A multivariate logistic regression model was used to compare demographic and social determinants of contraceptive choice among reproductive age women seeking long-acting contraception between the years 2005 and 2010. Results Among women using a long-acting contraceptive method in 2010, compared to 2005, women were significantly more likely to be sterilized (1.14 OR, 95% CI 1.09-1.18) and less likely to use LARC (0.88 OR, 95% CI 0.85-0.92). Of women seeking long-acting contraception, those exposed to a family planning provider were less likely to undergo sterilization (0.54 OR, 95% CI 0.51-0.58) and more likely to use LARC (1.84 OR, 95% CI 1.73-1.96). When compared to all contraceptive users, younger women and women with less than two children were more likely to use LARC than sterilization. Conclusion Between 2005 and 2010, an increase in the proportion of contracepting women being sterilized in Colombia occurred. Our findings suggest that exposure to a family planning provider and appropriate contraceptive counseling appears to be key determinants of long-acting contraceptive choice. To improve use of long-acting, effective contraception, efforts should be made to increase access to family planning providers.

  14. Ar + NO microwave plasmas for Escherichia coli sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Hueso, Jose L; Rico, Victor J; Cotrino, Jose; Gonzalez-Elipe, Agustin R [Instituto de Ciencia de Materiales de Sevilla, Centro Mixto CSIC-Universidad de Sevilla, Centro de Investigaciones Cientificas Isla de la Cartuja, Avda. Americo Vespucio 49, 41092 Sevilla (Spain); Frias, Jose E [Instituto de BioquImica Vegetal y FotosIntesis (IBVF-CSIC). Centro de Investigaciones CientIficas Isla de la Cartuja. Avda Americo Vespucio, 49, 41092 Sevilla (Spain)], E-mail: jhueso@icmse.csic.es

    2008-05-07

    Ar + NO microwave discharges are used for sterilization and the results are compared with additional experiments with Ar, O{sub 2} and N{sub 2}-O{sub 2} plasma mixtures. The NO{sup *} species produced in the Ar-NO mixtures remain up to long distances from the source, thus improving the sterilization efficiency of the process. E. coli individuals exposed to the Ar + NO plasma undergo morphological damage and cell lysis. Combined effects of etching (by O{sup *} and Ar{sup *} species) and UV radiation (from deactivation of NO{sup *} species) are responsible for the higher activity found for this plasma mixture. (fast track communication)

  15. Effect of sterilization on mineralization of straw and black carbon

    OpenAIRE

    Bobul'ská, Lenka; Bruun, Sander; Fazekašová, Danica

    2013-01-01

    The study was aimed at investigating the role of microorganisms in the degradation of BC (black carbon). CO evolution was measured under sterilized and non-sterilized soil using BC and straw amendments. Black carbon and straw were produced from homogenously C labelled roots of barley (Hordeum vulgare) with a specific activity 2.9 MBq g C. Production of BC was implemented at 300 °C for 24 h in a muffle oven, incubated in soil and C in the evolved CO was measured after 0.5, 1, 2, 4, 8, 16, 26 a...

  16. Insect population control by the sterile-male technique

    Energy Technology Data Exchange (ETDEWEB)

    Lindquist, A W

    1963-10-01

    The successful use of the sterile male technique to eradicate the screw worm fly from the Southeastern part of the United States showed that a new biological method using radiation-sterilized insects could not only control but also eradicate harmful insect pests. A panel of experts met at the IAEA in Vienna in October 1962 to discuss the various aspects and applications of this new technique and to assess its usefulness and limitations. This report summarizes the panel proceedings. 42 refs, 18 figs, 1 tab.

  17. Insect population control by the sterile-male technique

    International Nuclear Information System (INIS)

    Lindquist, A.W.

    1963-01-01

    The successful use of the sterile male technique to eradicate the screw worm fly from the Southeastern part of the United States showed that a new biological method using radiation-sterilized insects could not only control but also eradicate harmful insect pests. A panel of experts met at the IAEA in Vienna in October 1962 to discuss the various aspects and applications of this new technique and to assess its usefulness and limitations. This report summarizes the panel proceedings. 42 refs, 18 figs, 1 tab

  18. Control of anoplophora glabripennis by releasing sterile insects

    International Nuclear Information System (INIS)

    Liu Xiaohui; Li Yongjun; Zhang Shuyong; Wang Endong; Lu Daguang

    2003-01-01

    An experiment to evaluate the effect of released sterile insects on reproduction of natural A. glabripennis population was conducted at a 30-hectare poplar tree forest in Ying County of Shanxi Province from July 10 to August 29, 2001. Though the releasing ratio was only about 2-5, results from different methods showed that the reproduction of natural A. glabripennis population was suppressed effectively by releasing sterile insects, and that hatch ratio of eggs laid by parent generation was about 20% and survival ratio of F1 progeny about 27%. (authors)

  19. Searching for sterile neutrinos in dynamical dark energy cosmologies

    Science.gov (United States)

    Feng, Lu; Zhang, Jing-Fei; Zhang, Xin

    2018-05-01

    We investigate how the dark energy properties change the cosmological limits on sterile neutrino parameters by using recent cosmological observations. We consider the simplest dynamical dark energy models, the wCDM model and the holographic dark energy (HDE) model, to make an analysis. The cosmological observations used in this work include the Planck 2015 CMB temperature and polarization data, the baryon acoustic oscillation data, the type Ia supernova data, the Hubble constant direct measurement data, and the Planck CMB lensing data. We find that, m v,terile ff energy properties could significantly influence the constraint limits of sterile neutrino parameters.

  20. Economical aspects of radiation sterilization with electron beam

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.

    1998-01-01

    Radiation sterilization has been introduced in Poland in the early seventies. Since then continuous progress is observed in quantity of sterilized products. The commercial irradiation facility was built in 1993 to fulfill growing demands for radiation service. The real costs of running this plant were shown. The share of the cost of investment and the cost of maintenance and spare parts in accelerator exploitation, as well as the cost of one hour accelerator exploitation against time of one year accelerator exploitation were taken into account

  1. Sterilization of sera and vaccines by cobalt gamma radiation

    International Nuclear Information System (INIS)

    Guidolin, R.; Morais, J.F.; Higashi, H.G.; Correa, A.; Cicarelli, R.M.B.; Previde, E.

    1988-01-01

    Diphtheria, tetanus, anti-snake venom sera and Diphtheria-Pertussis-Tetanus vaccine were submitted to different intensities of gamma radiation, in order to: verify the resistance of their specific activities to the action of gamma rays; evaluate the possibility of using this type of energy to sterilize some heterogeneous hyper immune sera and vaccines commonly utilized in Public Health. The results, according to the range employed, show the possibility of sterilizing the products tested, without any alteration to specific biological and chemical properties. (author)

  2. Ar + NO microwave plasmas for Escherichia coli sterilization

    International Nuclear Information System (INIS)

    Hueso, Jose L; Rico, Victor J; Cotrino, Jose; Gonzalez-Elipe, Agustin R; Frias, Jose E

    2008-01-01

    Ar + NO microwave discharges are used for sterilization and the results are compared with additional experiments with Ar, O 2 and N 2 -O 2 plasma mixtures. The NO * species produced in the Ar-NO mixtures remain up to long distances from the source, thus improving the sterilization efficiency of the process. E. coli individuals exposed to the Ar + NO plasma undergo morphological damage and cell lysis. Combined effects of etching (by O * and Ar * species) and UV radiation (from deactivation of NO * species) are responsible for the higher activity found for this plasma mixture. (fast track communication)

  3. Implication of sterile fermions in particle physics and cosmology

    International Nuclear Information System (INIS)

    Lucente, M.

    2015-01-01

    The Ph.D. thesis work summarised in this manuscript was dedicated to studying several aspects of the phenomenology of Standard Model (SM) extensions by sterile fermions, in particular their impact for particle and astro-particle physics. An important part of the work is dedicated to a class of SM extensions which allow to explain the smallness of the observed neutrino masses (as well as their mixings) by linking them to the breaking of total lepton number, in the framework of the so-called Inverse seesaw mechanism (ISS). The work described in the thesis addresses the role of these sterile states in providing a satisfactory explanation to 3 open observational problems of the SM: the generation of neutrino masses and mixings, a viable dark matter candidate, and the dynamical generation of the baryon asymmetry of the Universe. We identified the minimal ISS realisation accounting for the observed neutrino data while at the same time complying with all available experimental and observational constraints. This study was based on a perturbative approach to the diagonalization of the neutrino mass matrix, which allowed to identify the number of states associated with the different mass scales. Our study revealed that, depending on the number of additional sterile fermion fields, the ISS can accommodate both a 3-flavour mixing scheme and a 3+more mixing scheme. The potential role of these sterile states as dark matter (DM) candidates led us to carry a dedicated study of the viability of the sterile fermion dark matter hypothesis in a minimal ISS realisation (in which the SM is extended by 2 right-handed neutrinos and 3 additional sterile fermion fields). The degeneracy in the sterile neutrino mass spectrum - which is characteristic of low scale seesaw models with approximate lepton number conservation - can play a relevant role in cosmology, since it allows us to explain the observed baryon asymmetry of the Universe via lepto-genesis. We identified different lepton number

  4. Radiation sterilization of pharmaceuticals: An overview of the literature

    International Nuclear Information System (INIS)

    Razem, D.

    2008-01-01

    Radiation sterilization of pharmaceuticals has never stopped attracting the attention of researchers. In this first as yet unfinished decade of the twenty-first century, the number of relevant papers seems to be on the rise again. In developing radiation sterilization of pharmaceuticals and searching for innovative applications, it is important to understand the end users, i.e. the pharmaceutical and medical professions. Mutual understanding between professions has already resulted in a plethora of products for enhancing, preserving and curing health, and many more are waiting to be discovered

  5. Nanomaterials for fresh-keeping and sterilization in food preservation.

    Science.gov (United States)

    Liu, Dongfang; Gu, Ning

    2009-06-01

    Food sterilizing and antistaling technologies are very important to the public's health and safety and have been attracting more and more attentions. In the past several years, new development chance was created by the introduction of nanomaterials to this critical field. Nanomaterials possess lots of outstanding properties, such as unique quantum size effect, large surface area and catalytic properties, which jointly facilitate high effective fresh-keeping, and thus were considered as promising materials in food sterilization and antistale. This review article focuses on the patented applications of nanomaterials as food biocidal agents, bacteriostatic agents, catalysts and carriers for antistaling agents.

  6. Recurrent population improvement of rice breeding facilitated with male sterility

    International Nuclear Information System (INIS)

    Fujimaki, Hiroshi

    1982-01-01

    A new rice breeding system has been developed, making use of genic male sterility to utilize diverse breeding materials and to promote genetic recombination. In this system, recurrent selection technique and introgressive hybridization were used to increase the frequencies of producing desired genotypes and to improve the population in succession. To promote genetic recombination by the recurrent selection technique, intermating within the population is necessary, and to introduce useful germ plasms by the introgressive hybridization, back crossing with new genetic material is necessary. These can be done efficiently by using the recessive alleles for male sterility, and the representative models for thisF type of breeding were presented. (Kaihara, S.)

  7. Sterilization, high-level disinfection, and environmental cleaning.

    Science.gov (United States)

    Rutala, William A; Weber, David J

    2011-03-01

    Failure to perform proper disinfection and sterilization of medical devices may lead to introduction of pathogens, resulting in infection. New techniques have been developed for achieving high-level disinfection and adequate environmental cleanliness. This article examines new technologies for sterilization and high-level disinfection of critical and semicritical items, respectively, and because semicritical items carry the greatest risk of infection, the authors discuss reprocessing semicritical items such as endoscopes and automated endoscope reprocessors, endocavitary probes, prostate biopsy probes, tonometers, laryngoscopes, and infrared coagulation devices. In addition, current issues and practices associated with environmental cleaning are reviewed. Copyright © 2011. Published by Elsevier Inc.

  8. New Orf virus (Parapoxvirus) recombinant expressing H5 hemagglutinin protects mice against H5N1 and H1N1 influenza A virus.

    Science.gov (United States)

    Rohde, Jörg; Amann, Ralf; Rziha, Hanns-Joachim

    2013-01-01

    Previously we demonstrated the versatile utility of the Parapoxvirus Orf virus (ORFV) as a vector platform for the development of potent recombinant vaccines. In this study we present the generation of new ORFV recombinants expressing the hemagglutinin (HA) or nucleoprotein (NP) of the highly pathogenic avian influenza virus (HPAIV) H5N1. Correct foreign gene expression was examined in vitro by immunofluorescence, Western blotting and flow cytometry. The protective potential of both recombinants was evaluated in the mouse challenge model. Despite adequate expression of NP, the recombinant D1701-V-NPh5 completely failed to protect mice from lethal challenge. However, the H5 HA-expressing recombinant D1701-V-HAh5n mediated solid protection in a dose-dependent manner. Two intramuscular (i.m.) injections of the HA-expressing recombinant protected all animals from lethal HPAIV infection without loss of body weight. Notably, the immunized mice resisted cross-clade H5N1 and heterologous H1N1 (strain PR8) influenza virus challenge. In vivo antibody-mediated depletion of CD4-positive and/or CD8-posititve T-cell subpopulations during immunization and/or challenge infection implicated the relevance of CD4-positive T-cells for induction of protective immunity by D1701-V-HAh5n, whereas the absence of CD8-positive T-cells did not significantly influence protection. In summary, this study validates the potential of the ORFV vectored vaccines also to combat HPAIV.

  9. Searching for a strategy to gamma-sterilize Portuguese cork stoppers - preliminary studies on bioburden, radioresistance and sterility assurance level

    International Nuclear Information System (INIS)

    Botelho, M.L.; Almeida-Vara, E.; Andrade, M.E.; Tenreiro, R.

    1988-01-01

    A gamma radiation plant will start running next year in Portugal, to sterilize medical devices and wine cork stoppers. As Portugal is the first world producer, manufacturer and exporter of wine cork stoppers, an efficient sterilizing procedure is required to overcome moulding from long term shipping. Preliminary research on cork stoppers bioburden and microflora radioresistance allowed to establish reliable D 10 and Sterility Assurance Level (SAL) values. Studied samples showed an initial average contamination of about 10 4 c.f.u. per cork stopper. The determined D 10 values for fungi were not higher than 2 kGy. In these conditions, a SAL of 10 -4 can be expected when the product is treated at a minimum absorbed dose of 15 kGy. (author)

  10. Studies on the ecology of insects sterilized artificially (gamma radiation), 7

    International Nuclear Information System (INIS)

    Kiyoku, Masao; Tsukuda, Ritsuko

    1974-01-01

    Larvae of an oriental fruit fly line introduced, from Amami-Oshima island were reared using an artificial medium prepared with the base ingredient as corn-flour. When pupae were irradiated with a dose of 8 kR from the 137 Cs as gamma-rays source two days before emerging, both male and female adults emerged showed complete sterility. Percentage in emergence, however, was not significantly reduced. In an experiment that two hundred sterilized plus ten normal males were confined with ten normal females in a mating cage, the sterilized males were fully competitive with normal ones in mating to the normal females. Longevity of the sterilized adult males, however, tended to be slightly shorter than that of the normal ones when compared in the survival curves. When less than one hundred and fifty sterilized males were confined, however, few larvae were able to grow to adults. These progeny adult males and females showed the inherited sterility. When dose was 6 kR there was neither significant difference in the longevity between sterilized and normal adults, nor the complete sterility. Besides, the inherited sterility in offspring was not shown clearly. When more than two hundred sterilized plus ten normal males were combined with ten normal females, however, a considerable sterility was found. Causes of the sterility were investigated by dissection of the testes and spermathecae in females mated with 8 kR-sterilized males. (author)

  11. Sterile insect technique. Principles and practice in area-wide integrated pest management

    International Nuclear Information System (INIS)

    Dyck, V.A.; Hendrichs, J.; Robinson, A.S.

    2005-01-01

    For several major insect pests, the environment-friendly sterile insect technique (SIT) is being applied as a component of area-wide integrated pest management (AW-IPM) programmes. This technology, using radiation to sterilize insects, was first developed in the USA, and is currently applied on six continents. For four decades it has been a major subject for research and development in the Joint FAO/IAEA Programme on Nuclear Techniques in Food and Agriculture, involving both research and the transfer of this technology to Member States so that they can benefit from improved plant, animal and human health, cleaner environments, increased production of plants and animals in agricultural systems, and accelerated economic development. The socio-economic impacts of AW-IPM programmes that integrate the SIT have confirmed the usefulness of this technology. Numerous publications related to the integration of the SIT in pest management programmes, arising from research, coordinated research projects, field projects, symposia, meetings, and training activities have already provided much information to researchers, pest-control practitioners, programme managers, plant protection and animal health officers, and policy makers. However, by bringing together and presenting in a generic fashion the principles, practice, and global application of the SIT, this book will be a major reference source for all current and future users of the technology. The book will also serve as a textbook for academic courses on integrated pest management. Fifty subject experts from 19 countries contributed to the chapters, which were all peer reviewed before final editing

  12. Sterilized PP/HMSPP cushion foams for medical and food packaging applications

    International Nuclear Information System (INIS)

    Cardoso, Elisabeth C.L.; Lima, L. Filipe C.P.; Parra, Duclerc F.; Lugao, Ademar B.; Bueno, N.R.; Gasparin, Eleosmar

    2009-01-01

    Treatment with gamma radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in aseptic processing of foods and pharmaceuticals. Packaging materials may be irradiated either prior or after filling; the irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceuticals and medical devices. Cushion foams are used to help protect fragile items during moving transport. Shock, vibration and damage are avoided by the cushioning effect and chances of product damage are reduced. It is easy to use and perforated for easy tearing. Cushion foams are employed to wrap glasses, plates, crockery, lamps, electronics and other breakable items. This paper presents special cushion foams to be used for medical and food packaging applications; so, these foams will be gamma irradiated before getting in contact with these special articles. Foams were previously produced from a 50% blending Polypropylene homopolymer / High Melt Strength Polypropylene (HMSPP) thereof, that presented following results for properties assessed: melt flow index, 230 deg C - 3.67 g/10 minutes; crystallinity = 47%; melt strength, at 200 deg C = 7.3 cN. This admixture was further fed into the barrel of a single-screw extruder, Rheomex 332 p, equipped with 3:1,33 d screw and 19/33 special screw for foaming, with standard controller and monitored panel, temperature controller (2 channels), melt temperature (2 channels) and melt pressure (4 channels). By using a 175/200/210/220/165/25 (deg C) profile temperature, and after attaining a homogeneous melting, a given amount of physical blowing agent (nitrogen) was injected and mixed with the polymer melt stream to produce the foam. Foamed extrudate was subjected to sterilization radiation doses: 25, 50, 75 and 100 kGy and further evaluated as per: appearance (whiteness / yellowness) and temperature dependent oxidative-induction time (TOIT) tests, by comparing

  13. Studies of soy sauce sterilization and its special flavour improvement by gamma-ray irradiation

    International Nuclear Information System (INIS)

    Yang Jingtian; Jin Xinhua; Gu Guoxing; Yun Guichun

    1988-01-01

    Experimental studies for sterilizing 12 kinds of soy sauce with gamma-ray irradiation showed that both sterilization and improvements in flavour and quality of soy sauce were obtained simultaneously. (author)

  14. Present studies on the radio-sterilized drugs; Aktualny stan badan nad lekami sterylizowanymi radiacyjnie

    Energy Technology Data Exchange (ETDEWEB)

    Marciniec, B; Dettlaff, K [Department of Pharmaceutical Chemistry, Poznan University of Medical Sciences, Poznan (Poland)

    2007-07-01

    Lecture presents present status of radiosterilization of drugs and medical materials as compared to other sterilization methods. Literature review is shown on degradation of different kinds of drugs sterilized upon action of the sterilising doses of radiation.

  15. FUNCTIONAL MALE STERILITY AND ITS USE IN BREEDING OF VEGETABLE AND MELON CROPS

    Directory of Open Access Journals (Sweden)

    A. N. Bocharnikov

    2014-01-01

    Full Text Available The article describes the manifestation of functional male sterility and its importance in the breeding of melons. Utilization of functional male sterility allows solving the problem effective hybrid seed production.

  16. Current systems of sterilization in the Philippines in both government and private hospitals

    International Nuclear Information System (INIS)

    Lim, L.E.

    1996-01-01

    In the Philippines, there are 1,700 registered hospitals, both private and government. There are 80,000 beds. The systems of sterilization are mainly using steam or to use ethylene oxide sterilization. Gamma ray sterilization is purely on experimental basis and very limited scale for industrial products. The author will trace the history of sterilization, practised since a century ago and trace back to the present system of sterilization. The principles applied, precautions and limitations or advantages of the different systems will be discussed particularly steam sterilization and ethylene oxide. Other forms of sterilization either chemical or physical will be discussed in passing. Experience in gamma ray sterilization in Japan and Australia will be presented when available data are obtained, to encourage local investors to engage in such venture. Philippines has been left behind by our neighbors. (author)

  17. Effectiveness and feasibility of hysteroscopic sterilization techniques: a systematic review and meta-analysis

    NARCIS (Netherlands)

    la Chapelle, C.F.; Veersema, S.; Brölmann, H.A.M.; Jansen, F.W.

    2015-01-01

    Objective To assess whether hysteroscopic sterilization is feasible and effective in preventing pregnancy. Secondarily, to identify risk factors for failure of hysteroscopic sterilization. Design A systematic review and meta-analysis. Setting Not applicable. Patient(s) Women undergoing hysteroscopic

  18. FUNCTIONAL MALE STERILITY AND ITS USE IN BREEDING OF VEGETABLE AND MELON CROPS

    OpenAIRE

    A. N. Bocharnikov

    2014-01-01

    The article describes the manifestation of functional male sterility and its importance in the breeding of melons. Utilization of functional male sterility allows solving the problem effective hybrid seed production.

  19. Hybrid male sterility and genome-wide misexpression of male reproductive proteases.

    Science.gov (United States)

    Gomes, Suzanne; Civetta, Alberto

    2015-07-06

    Hybrid male sterility is a common barrier to gene flow between species. Previous studies have posited a link between misregulation of spermatogenesis genes in interspecies hybrids and sterility. However, in the absence of fully fertile control hybrids, it is impossible to differentiate between misregulation associated with sterility vs. fast male gene regulatory evolution. Here, we differentiate between these two possibilities using a D. pseudoobscura species pair that experiences unidirectional hybrid sterility. We identify genes uniquely misexpressed in sterile hybrid male reproductive tracts via RNA-seq. The sterile male hybrids had more misregulated and more over or under expressed genes relative to parental species than the fertile male hybrids. Proteases were the only gene ontology class overrepresented among uniquely misexpressed genes, with four located within a previously identified hybrid male sterility locus. This result highlights the potential role of a previously unexplored class of genes in interspecific hybrid male sterility and speciation.

  20. Laparoscopic Filshie clip sterilization and selective use of the methylene blue dye test.

    Science.gov (United States)

    Karoshi, Mahantesh; Yoong, Wai

    2004-01-01

    In laparoscopic Filshie clip sterilization, difficulties may arise in identifying the length of the fallopian tube, with the possibility of failure of sterilization. This article describes a novel intraoperative method of demonstrating adequate tubal closure.

  1. Sterilization plants equipped with the isotopic gamma radiation sources

    International Nuclear Information System (INIS)

    Mehta, K.; Chmielewski, A.G.

    2007-01-01

    Presentation describes different isotopic gamma radiation sources applicable for sterilization of food and medical materials. Certain gamma pallet irradiators, mini gamma irradiators and different scale gamma tote irradiators are presented. It is concluded, that about two hundreds plants with gamma radiation sources operates in different countries. However, industrially developed countries must construct much more plants than operates now

  2. Spikelet sterility in rice genotypes affected by temperature at microsporogenesis

    Directory of Open Access Journals (Sweden)

    Natalia M. de Souza

    Full Text Available ABSTRACT This study evaluated the effect of temperatures during the phase of microsporogenesis on spikelet sterility of paddy rice and identified genotypes tolerant to low temperatures at this growth stage. The inbreds SC681, SC491, and SC676 and the cultivars Epagri 109 and SCS116 Satoru were assessed. The genotypes were submitted for three days in a growth chamber to five temperatures at microsporogenesis: 9, 12, 15, 18, and 21 oC. For each tested temperature, a control was kept in the greenhouse under environmental conditions. After harvest, full and empty spikelets were counted and weighed and the percentage of spikelet sterility was determined. Data were evaluated by variance analysis using the F test. Averages were compared by Tukey’s test and regression analysis. The highest spikelet sterilities were observed when the genotypes were exposed to the temperatures of 9 and 12 oC. Genotype spikelet sterility was similar to that of the control at 21 ºC. The inbred SC 676 presented higher tolerance to lower temperatures is therefore potentially suited to generate a cultivar with adequate agronomic performance in rice growing areas prone to cold conditions at microsporogenesis.

  3. Surface sterilization and duration of seed storage influenced ...

    African Journals Online (AJOL)

    The effects of factorial combinations of four storage duration (in days after seed extraction) and surface sterilization with three dilution levels of sodium hypochlorite on seedling emergence and seedling quality of African breadfruit were studied. Storage duration significantly influenced days to seedling emergence, ...

  4. Microbicidal effectiveness of X-rays used for sterilization purposes

    DEFF Research Database (Denmark)

    Tallentire, Alan; Miller, Arne

    2015-01-01

    The radiation response of spores of Bacillus pumilus was examined for irradiation with 5–7 MeV X-ray at commercial sterilization facilities. The response was found to be the same as that for irradiation with cobalt 60 photons, 10 MeV electrons and low energy electrons at 100 and 80 keV....

  5. Characterization of Prdm9 in equids and sterility in mules.

    Directory of Open Access Journals (Sweden)

    Cynthia C Steiner

    Full Text Available Prdm9 (Meisetz is the first speciation gene discovered in vertebrates conferring reproductive isolation. This locus encodes a meiosis-specific histone H3 methyltransferase that specifies meiotic recombination hotspots during gametogenesis. Allelic differences in Prdm9, characterized for a variable number of zinc finger (ZF domains, have been associated with hybrid sterility in male house mice via spermatogenic failure at the pachytene stage. The mule, a classic example of hybrid sterility in mammals also exhibits a similar spermatogenesis breakdown, making Prdm9 an interesting candidate to evaluate in equine hybrids. In this study, we characterized the Prdm9 gene in all species of equids by analyzing sequence variation of the ZF domains and estimating positive selection. We also evaluated the role of Prdm9 in hybrid sterility by assessing allelic differences of ZF domains in equine hybrids. We found remarkable variation in the sequence and number of ZF domains among equid species, ranging from five domains in the Tibetan kiang and Asiatic wild ass, to 14 in the Grevy's zebra. Positive selection was detected in all species at amino acid sites known to be associated with DNA-binding specificity of ZF domains in mice and humans. Equine hybrids, in particular a quartet pedigree composed of a fertile mule showed a mosaic of sequences and number of ZF domains suggesting that Prdm9 variation does not seem by itself to contribute to equine hybrid sterility.

  6. Experimental study on lyophilized irradiation sterilized nerve allografts in rabbits

    International Nuclear Information System (INIS)

    Yang Zhiyuan; Sun Shiquan; Liu Hechen

    1991-01-01

    Lyophilized irradiation sterilized nerve grafts in rabbits were used in allogeneic nerve transplantation. The result show that about 76% of experimental rabbits had fairly well morphologic (microscopic and electron microscopic) and electrophysiological recovery 3 month after operation. Preservation of neurilemmal tubes in nerve grafts, repopulation of Schwann cells in this tube and suppression of immune rejection are the key points in allogeneic nerve transplantation

  7. Surgical sterilization of the African giant pouched rats | Werema ...

    African Journals Online (AJOL)

    ... to all principles of surgery. This study has demonstrated the three surgical procedures for African Giant pouched rats as being useful to veterinarians in public/private practice and/or in biomedical research facilities. Keywords: Surgical sterilization, ovariectomy, ovariohysterectomy, orchidectomy, African giant pouched rats ...

  8. Effect of delayed sterilization on the production of intravenous fluids ...

    African Journals Online (AJOL)

    % (w/v) dextrose solution was studied. The 5% (w/v) dextrose was prepared with distilled water. The solution was inoculated with a laboratory isolate of Escherichia coli and thereafter divided into two: Solutions A and B. Sample A was sterilized ...

  9. Feasibility of sterilizing traditional Chinese medicines by gamma-irradiation

    International Nuclear Information System (INIS)

    Fang Xingwang; Wu Jilan

    1998-01-01

    The feasibility of sterilizing traditional Chinese medicines (TCMs) by γ-irradiation has been systematically evaluated by the biological, toxicological and physicochemical tests on irradiated hundreds of TCMs. Those TCMs investigated in general show no significant biological or toxicological changes after irradiation, yet physicochemical changes are detectable in some irradiated TCMs, and water in TCMs enhances the effects. Those results obtained from radiolysis of some major effective components of TCMs in aqueous or ethanolic solutions reveal that the site selection of radiolytically generated radicals follows the example of simple compounds with same function groups. Wholesomeness and chemical clearance present a bright future to sterilizing TCMs by γ irradiation, however, some important measures and steps should be adopted: (1) The producers must strictly execute manufacturing procedure to reduce microbiological contamination thus lower the applied dose for sterilization which is recommended to be controlled under 5, 7 or 10 kGy for dry herb, 7 kGy for herbal medicine and 5 kGy for some special herbal medicine; (2) Herb to be sterilized by γ-irradiation should exist in possible dry state; (3) Powder TCMs is recommended to mix with honey forming bolus, which can minimize the decomposition of herb

  10. Search for heavy sterile neutrinos with SHiP

    CERN Document Server

    Jacobsson, Richard

    Invited contribution to the White Paper on keV sterile neutrino Dark Matter as proceedings of the v-Dark 2015 international workshop which was held at the Institute for Advanced Study of the Technical University of Munich, Garching, Germany, 7 - 9 December 2015. White Paper will be submitted to JCAP.

  11. Assessing genetic variability in male sterile and low fertile citrus ...

    African Journals Online (AJOL)

    Yomi

    2012-01-24

    Jan 24, 2012 ... male sterile types, with old scattered resources; Iran has obvious diversity of citrus materials. ... From each accession, four young leaves were taken and total genomic DNA was ..... sexual reproduction and recombination are disabled in detecting such mutations in asexually propagated species. Therefore ...

  12. Radio-sterilization effects on adult males of Glossina tachinoides ...

    African Journals Online (AJOL)

    Induced sterility of adult males of Glossina tachiniodes irradiated with gamma doses of 130, 150 and 160 Gy, respectively, in air was investigated. The flies were irradiated at horizontal distances of 50 cm and 70 cm, respectively from the Gamma Facility. The mean percentage insemination of spermathecae ranged between ...

  13. Dosimetry intercomparisons in European medical device sterilization plants

    DEFF Research Database (Denmark)

    Miller, A.; Sharpe, P.H.G.

    2000-01-01

    Dosimetry intercomparisons have been carried out involving two-thirds of all European radiation sterilization facilities. Dosimeters for the intercomparisons were supplied by two accredited calibration laboratories. The results show good agreement, and indicate overall dosimetry accuracy of the o...... of the order of +/-5% (1 sigma) for both Co-60 and electron beam plants. (C) 2000 Elsevier Science Ltd. All rights reserved....

  14. Influence of heat sterilization on the organoleptic quality of spices

    NARCIS (Netherlands)

    Maarse, H.; Nijssen, L.M.; Nowak, M.

    1982-01-01

    Heat sterilization and storage of food products containing spices often results in a change of their organoleptic quality. Our knowledge about the stability of individual spices, however, is low. Therefore the heat stability of 8 different spices most frequently used has been investigated: cinnamon,

  15. Sterile neutrinos with secret interactions—lasting friendship with cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Xiaoyong [International Center for Theoretical Physics, Strada Costiera 11, Trieste, 34014 Italy (Italy); Dasgupta, Basudeb [Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai, 400005 India (India); Kopp, Joachim, E-mail: xchu@ictp.it, E-mail: bdasgupta@theory.tifr.res.in, E-mail: jkopp@uni-mainz.de [PRISMA Cluster of Excellence and Mainz Institute for Theoretical Physics, Johannes Gutenberg University, Staudingerweg 7, Mainz, 55128 Germany (Germany)

    2015-10-01

    Sterile neutrinos with mass ≅ 1 eV and order 10% mixing with active neutrinos have been proposed as a solution to anomalies in neutrino oscillation data, but are tightly constrained by cosmological limits. It was recently shown that these constraints are avoided if sterile neutrinos couple to a new MeV-scale gauge boson A'. However, even this scenario is restricted by structure formation constraints when A'-mediated collisional processes lead to efficient active-to-sterile neutrino conversion after neutrinos have decoupled. In view of this, we reevaluate in this paper the viability of sterile neutrinos with such ''secret'' interactions. We carefully dissect their evolution in the early Universe, including the various production channels and the expected modifications to large scale structure formation. We argue that there are two regions in parameter space—one at very small A' coupling, one at relatively large A' coupling—where all constraints from big bang nucleosynthesis (BBN), cosmic microwave background (CMB), and large scale structure (LSS) data are satisfied. Interestingly, the large A' coupling region is precisely the region that was previously shown to have potentially important consequences for the small scale structure of dark matter halos if the A' boson couples also to the dark matter in the Universe.

  16. Sterile neutrinos with secret interactions — lasting friendship with cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Xiaoyong [International Center for Theoretical Physics,Strada Costiera 11, Trieste, 34014 (Italy); Dasgupta, Basudeb [Tata Institute of Fundamental Research,Homi Bhabha Road, Mumbai, 400005 (India); Kopp, Joachim [PRISMA Cluster of Excellence and Mainz Institute for Theoretical Physics,Johannes Gutenberg University, Staudingerweg 7, Mainz, 55128 (Germany)

    2015-10-06

    Sterile neutrinos with mass ≃1 eV and order 10% mixing with active neutrinos have been proposed as a solution to anomalies in neutrino oscillation data, but are tightly constrained by cosmological limits. It was recently shown that these constraints are avoided if sterile neutrinos couple to a new MeV-scale gauge boson A{sup ′}. However, even this scenario is restricted by structure formation constraints when A{sup ′}-mediated collisional processes lead to efficient active-to-sterile neutrino conversion after neutrinos have decoupled. In view of this, we reevaluate in this paper the viability of sterile neutrinos with such “secret” interactions. We carefully dissect their evolution in the early Universe, including the various production channels and the expected modifications to large scale structure formation. We argue that there are two regions in parameter space — one at very small A{sup ′} coupling, one at relatively large A{sup ′} coupling — where all constraints from big bang nucleosynthesis (BBN), cosmic microwave background (CMB), and large scale structure (LSS) data are satisfied. Interestingly, the large A{sup ′} coupling region is precisely the region that was previously shown to have potentially important consequences for the small scale structure of dark matter halos if the A{sup ′} boson couples also to the dark matter in the Universe.

  17. Sterile neutrinos in lepton number and lepton flavor violating decays

    International Nuclear Information System (INIS)

    Helo, Juan Carlos; Kovalenko, Sergey; Schmidt, Ivan

    2011-01-01

    We study the contribution of massive dominantly sterile neutrinos, N, to the lepton number and lepton flavor violating semileptonic decays of τ and B, D, K-mesons. We focus on special domains of sterile neutrino masses m N where it is close to its mass-shell. This leads to an enormous resonant enhancement of the decay rates of these processes. This allows us to derive stringent limits on the sterile neutrino mass m N and its mixing U αN with active flavors. We apply a joint analysis of the existing experimental bounds on the decay rates of the studied processes. In contrast to other approaches in the literature our limits are free from ad hoc assumptions on the relative size of the sterile neutrino mixing parameters. We analyze the impact of this sort of assumptions on the extraction of the limits on m N and U αN , and discuss the effect of finite detector size. Special attention was paid to the limits on meson decays with e ± e ± in final state, derived from non-observation of 0νββ-decay. We point out that observation of these decays may, in particular, shed light on the Majorana phases of the neutrino mixing matrix.

  18. [Characteristics and follow-up of sterilized women].

    Science.gov (United States)

    Molina, R; López, I

    1982-02-01

    In order to gain insight into the characteristics of sterilized women evaluating at the same time the effects of sterilization, 70 patients who underwent sterilization in an Obstetrics Unit were studied. The clinical records were analyzed and a questionnaire comprising general knowledge, attitudes, and conduct was applied. Women over 30 and with a parity of 4 or more predominated. There was a low frequency of abortions reported but this information is not reliable. The educational level was lower than the average for the Metropolitan Region and pointed to a more precocious initiation in sexual relationships than was found in a previous similar study. Religion proved to be no obstacle for sterilization nor was attendance to church subsequently diminished. A negative moral feeling towards the operation nearly disappeared following surgery. The fear of sexual dissatisfaction in husbands decreased following surgery and a similar effect was seen with regard to negative self-image. There were no changes in marital relations nor in their satisfaction. (author's modified)

  19. Sterilization Effect of Wet Oxygen Plasma in the Bubbling Method.

    Science.gov (United States)

    Tamazawa, Kaoru; Shintani, Hideharu; Tamazawa, Yoshinori; Shimauchi, Hidetoshi

    2015-01-01

    A new low-temperature sterilization method to replace the ethylene oxide gas sterilization is needed. Strong bactericidal effects of OH and O2H radicals are well known. The purpose of this study was to evaluate the sterilization effect of wet oxygen ("O2+H2O") plasma in the bubbling method, confirming the effect of humidity. Sterility assurance was confirmed by using a biological indicator (Geobacillus stearothermophilus ATCC7953, Namsa, USA). One hundred and eight samples (10(5) spores/carrier) were divided into three groups of 36 in each for treatment with a different type of gas (O2, O2+H2O, Air+H2O). Plasma processing was conducted using a plasma ashing apparatus (13.56 MHz, PACK-3(®), Y. A. C., Japan) under various gas pressures (13, 25, 50 Pa) and gas flows (50, 100, 200 sccm). Fixed plasma treatment parameters were power at 150 W, temperature of 60 ℃, treatment time of 10 min. The samples after treatment were incubated in trypticase soy broth at 58 ℃ for 72 h. The negative culture rate in the "O2+H2O" group was significantly (Mantel-Haenszel procedure, pbubbling method which is the method of introducing vapor into the chamber. The bubbling method seems able to generate OH and O2H radicals in a stable way.

  20. Revision of the ISO and EN radiation sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.; Hansen, J.

    2002-01-01

    The radiation sterilization standards, ISO 11137 and EN 552, are now being revised under "ISO lead", with the aim of producing only one international standard, although in four parts: (1) requirements. (2) dose-setting methods, (3) dose-substantiation methods and (4) dosimetry. Several aspects...

  1. Microbial Evaluation of Some Non-sterile Pharmaceutical ...

    African Journals Online (AJOL)

    Purpose: To determine the type and incidence of predominant microorganisms in certain non-sterile pharmaceuticals immediately after collection and one year later. Methods: All pharmaceutical samples were subjected to the following examinations: total bacterial count and presence of microbial pathogens, using ...

  2. Field dosimetry on sterilization area of medical-hospitable materials

    International Nuclear Information System (INIS)

    Mariano, C.S.T.P.; Campos, L.L.

    1992-01-01

    The calcium sulfate doped with dysprosium, used in high dose dosimetry by electron paramagnetic resonance (EPR), is studied on field dosimetry for medical-hospitable materials sterilization. The calibration curves of EPR signal in function of absorbed dose in air and the thermal decay of EPR signal at room temperature are also presented. (C.G.C)

  3. Radiation sterilization of medical products in the Philippines

    Science.gov (United States)

    Singson, C.; Carmona, C.; de Guzman, Z.; Barrun, W.; Lanuza, L.

    This paper presents the results of a comprehensive investigation of the biological, microbiological, physico-chemical, and dosimetry aspects of using gamma irradiation for the sterilization of locally manufactured medical products and pharmaceuticals. The objective of this study is to determine the technological feasibility of radiation sterilization for the said products in the Philippines. Hence, the materials used were directly obtained from local manufacturers. They are polyvinyl chloride or polyethylene based medical plastic disposables namely: absorbent cotton, surgical gauze, bandage, visceral packs, and some antibiotics and opthalmic ointments. The gamma facility of the Philippine Atomic Energy Commission was used for the irradiation. Result of biological studies indicate no signs of toxicity on experimental mice injected with extracts from irradiated samples. The contaminants are identified as Pseudomonas Sp. Staphyloccocus Aureus and Bacillus Subtilis. The D 10 values of survivors of higher doses ranged below 0.235 Megarad suggesting that these contaminants can be eliminated by the generally used sterilizing dose of 2.5 Mrads. The physico-chemical tests did not indicate any significant degradation of the irradiated products. Opthalmic and topical antibiotic ointments showed no marked decrease in potency. Fading tests on dosimeters used showed that red perspex is a more efficient dosimeter than clear perspex when irradiation time is prolonged. These studies indicated that radiation sterilization is technically feasible for locally manufactured medical products.

  4. Comparison of Sterile and Clean Dressing Techniques in Post ...

    African Journals Online (AJOL)

    Pharmacotherapy Group, Faculty of Pharmacy, University of Benin, Benin City, ... Chinese hospital, and to compare their impact on wound healing and the cost of the ... up to the time of their discharge. Results: Twelve (18.5 %) patients out of those who received sterile or clean .... identified using automated means [13,14].

  5. The use of sterilized mosquito nets for hernioplasty

    DEFF Research Database (Denmark)

    Sørensen, C G; Rosenberg, J

    2012-01-01

    Hernia repair is among the most frequent surgeries performed. Surgeons prefer the tension-free mesh repair, but in large parts of the world, commercial meshes are unavailable or unaffordable. Consequently, surgeons have been experimenting with insertion of inexpensive non-commercial meshes, the m......, the most common being a non-impregnated, sterilized mosquito net....

  6. Characterization of Prdm9 in equids and sterility in mules.

    Science.gov (United States)

    Steiner, Cynthia C; Ryder, Oliver A

    2013-01-01

    Prdm9 (Meisetz) is the first speciation gene discovered in vertebrates conferring reproductive isolation. This locus encodes a meiosis-specific histone H3 methyltransferase that specifies meiotic recombination hotspots during gametogenesis. Allelic differences in Prdm9, characterized for a variable number of zinc finger (ZF) domains, have been associated with hybrid sterility in male house mice via spermatogenic failure at the pachytene stage. The mule, a classic example of hybrid sterility in mammals also exhibits a similar spermatogenesis breakdown, making Prdm9 an interesting candidate to evaluate in equine hybrids. In this study, we characterized the Prdm9 gene in all species of equids by analyzing sequence variation of the ZF domains and estimating positive selection. We also evaluated the role of Prdm9 in hybrid sterility by assessing allelic differences of ZF domains in equine hybrids. We found remarkable variation in the sequence and number of ZF domains among equid species, ranging from five domains in the Tibetan kiang and Asiatic wild ass, to 14 in the Grevy's zebra. Positive selection was detected in all species at amino acid sites known to be associated with DNA-binding specificity of ZF domains in mice and humans. Equine hybrids, in particular a quartet pedigree composed of a fertile mule showed a mosaic of sequences and number of ZF domains suggesting that Prdm9 variation does not seem by itself to contribute to equine hybrid sterility.

  7. Current status of backcross sterility in Heliothis virescens (F.)

    International Nuclear Information System (INIS)

    Hardee, D.D.; Laster, M.L.

    1996-01-01

    Because of insecticide resistance, high cost of controls and the need to reduce pesticide use, attempts have been made to manage Heliothis virescens with non-insecticidal techniques. One such approach has been the use of sterile male interspecific hybrids produced from crosses between males of H. virescens and females of H. subflexa

  8. The sterile immune response during hepatic ischemia/reperfusion

    NARCIS (Netherlands)

    van Golen, Rowan F.; van Gulik, Thomas M.; Heger, Michal

    2012-01-01

    Hepatic ischemia and reperfusion elicits an immune response that lacks a microbial constituent yet poses a potentially lethal threat to the host. In this sterile setting, the immune system is alarmed by endogenous danger signals that are release by stressed and dying liver cells. The detection of

  9. 21 CFR 522.1881 - Sterile prednisolone acetate aqueous suspension.

    Science.gov (United States)

    2010-04-01

    ... and for various stress conditions when corticosteroids are required while the animal is being treated... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.1881 Sterile prednisolone acetate aqueous suspension. (a) Specifications. Each...

  10. Proteomic Analysis of Pachytene Spermatocytes of Sterile Hybrid Male Mice.

    Science.gov (United States)

    Wang, Lu; Guo, Yueshuai; Liu, Wenjing; Zhao, Weidong; Song, Gendi; Zhou, Tao; Huang, Hefeng; Guo, Xuejiang; Sun, Fei

    2016-09-01

    Incompatibilities in interspecific hybrids, such as reduced hybrid fertility and lethality, are common features resulting from reproductive isolation that lead to speciation. Subspecies crosses of house mice produce offspring in which one sex is infertile or absent, yet the molecular mechanisms of hybrid sterility are poorly understood. In this study, we observed extensive asynapsis of chromosomes and disturbance of the sex body in pachytene spermatocytes of sterile F1 males (PWK/Ph female × C57BL/6J male). We report the high-confidence identification of 4005 proteins in the pachytene spermatocytes of fertile F1 males (PWK/Ph male × C57BL/6J female) and sterile F1 males (PWK/Ph female × C57BL/6J male), of which 215 were upregulated and 381 were downregulated. Bioinformatics analysis of the proteome led to the identification of 43 and 59 proteins known to be essential for male meiosis and spermatogenesis in mice, respectively. Characterization of the proteome of pachytene spermatocytes associated with hybrid male sterility provides an inventory of proteins that is useful for understanding meiosis and the mechanisms of hybrid male infertility. © 2016 by the Society for the Study of Reproduction, Inc.

  11. Mechanisms Underlying Mammalian Hybrid Sterility in Two Feline Interspecies Models.

    Science.gov (United States)

    Davis, Brian W; Seabury, Christopher M; Brashear, Wesley A; Li, Gang; Roelke-Parker, Melody; Murphy, William J

    2015-10-01

    The phenomenon of male sterility in interspecies hybrids has been observed for over a century, however, few genes influencing this recurrent phenotype have been identified. Genetic investigations have been primarily limited to a small number of model organisms, thus limiting our understanding of the underlying molecular basis of this well-documented "rule of speciation." We utilized two interspecies hybrid cat breeds in a genome-wide association study employing the Illumina 63 K single-nucleotide polymorphism array. Collectively, we identified eight autosomal genes/gene regions underlying associations with hybrid male sterility (HMS) involved in the function of the blood-testis barrier, gamete structural development, and transcriptional regulation. We also identified several candidate hybrid sterility regions on the X chromosome, with most residing in close proximity to complex duplicated regions. Differential gene expression analyses revealed significant chromosome-wide upregulation of X chromosome transcripts in testes of sterile hybrids, which were enriched for genes involved in chromatin regulation of gene expression. Our expression results parallel those reported in Mus hybrids, supporting the "Large X-Effect" in mammalian HMS and the potential epigenetic basis for this phenomenon. These results support the value of the interspecies feline model as a powerful tool for comparison to rodent models of HMS, demonstrating unique aspects and potential commonalities that underpin mammalian reproductive isolation. © The Author 2015. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Genetics and evolution of hybrid male sterility in house mice.

    Science.gov (United States)

    White, Michael A; Stubbings, Maria; Dumont, Beth L; Payseur, Bret A

    2012-07-01

    Comparative genetic mapping provides insights into the evolution of the reproductive barriers that separate closely related species. This approach has been used to document the accumulation of reproductive incompatibilities over time, but has only been applied to a few taxa. House mice offer a powerful system to reconstruct the evolution of reproductive isolation between multiple subspecies pairs. However, studies of the primary reproductive barrier in house mice-hybrid male sterility-have been restricted to a single subspecies pair: Mus musculus musculus and Mus musculus domesticus. To provide a more complete characterization of reproductive isolation in house mice, we conducted an F(2) intercross between wild-derived inbred strains from Mus musculus castaneus and M. m. domesticus. We identified autosomal and X-linked QTL associated with a range of hybrid male sterility phenotypes, including testis weight, sperm density, and sperm morphology. The pseudoautosomal region (PAR) was strongly associated with hybrid sterility phenotypes when heterozygous. We compared QTL found in this cross with QTL identified in a previous F(2) intercross between M. m. musculus and M. m. domesticus and found three shared autosomal QTL. Most QTL were not shared, demonstrating that the genetic basis of hybrid male sterility largely differs between these closely related subspecies pairs. These results lay the groundwork for identifying genes responsible for the early stages of speciation in house mice.

  13. Gamma irradiation for food preservation and sterilization of medical supplies

    International Nuclear Information System (INIS)

    Syed Abid Husain; Mohammad Said Kadis

    1981-01-01

    A new technology in food preservation by using gamma irradiation was introduced and its advantages over a number of conventional processes were discussed. The new technique is also applicable in the sterilization of medical supplies. It is relatively simple and does not require very highly skilled manpower

  14. Development and Validation of Sterility Systems for Trees

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, Steve; Shevchenko, Olga; Ma, Caiping (Cathleen)

    2007-03-30

    The overall goal of this project was to develop and validate sterility systems in poplar with the ultimate goal of fulfilling the basic requirements for commercial use. For this, sterility must be complete and stable over multiple growing seasons, cause no detrimental effects on vegetative growth, and successful transformation events must be identifiable via molecular tests when trees are still juvenile. Because of the inherent difficulties in achieving and demonstrating complete sterility in trees, our approach was to study alternate sterility systems in Arabidopsis and/or early-flowering tree systems. The public benefit from this work is the capacity for containment of genes or exotic forms of trees so they can be of benefit for industry for production of wood, energy, and renewable products, while having minimal impact on wild populations of trees. We tested three methods for engineering sterility: dominant negative mutant (DNM) proteins, floral tissue ablation, and RNA interference (RNAi) to suppress the expression of several floral regulatory genes. The ultimate goal of this work was to produce a number of transgenic poplars that could be outplanted to enable future assessments of the effectiveness of these transgenic sterility methods. Our attempts to produce ablation constructs that did not interfere with tree health were partially successful. Using the poplar LEAFY gene promoter and the barnase/barstar system, we were able to regenerate plants that grew well in the greenhouse, but they showed poor health in the field. Four of seven DNM genes tested were considered promising enough, based on results in Arabidopsis, to produce transgenic poplars. Single, double, and triple RNAi genes were produced and transformed into poplar. Over all, we produced 1,964 PCR-confirmed transgenic events with 19 different kinds of sterility genes and several kinds of control genes. We propagated 5,640, 6,820, and 7,055 trees for each of three test poplar genotypes, and field

  15. Evaluation of Effects of Sterilization on Mechanical Properties of Orthodontic Wires

    Directory of Open Access Journals (Sweden)

    Sridhar Kannan

    2012-01-01

    Results: Dry heat sterilization, autoclave, 2% glutaraldehyde solution had no effect on ultimate tensile strength, 0.1% yield strength, modulus of elasticity and percentage elongation of stainless steel and elgiloy wires. Tensile strength and yield strength of Nitinol and b-titanium wires together with percentage elongation of b-titanium wires significantly increased following dry heat sterilization and autoclave. No detrimental effects on properties of wires were observed. These sterilization procedures could be safely recommended for sterilization of orthodontic wires.

  16. Radiation Sterilization of Two Commonly Culture Media Used for Bacterial Growth

    International Nuclear Information System (INIS)

    El-Hifnawi, H.N.

    2008-01-01

    Radiation sterilization of culture media used for the cultivation of bacteria by Co-60 gamma ray was investigated. Nutrient agar and tryptone glucose yeast extract (TGY) media widely used for the propagation of bacteria were sterilized with 15 kGy dose gamma radiation. Seven different bacterial species were grown as well on the radiation sterilized media as on media sterilized by autoclaving in a conventional way

  17. Haldaneovo pravidlo a mechanismy hybridní sterility samic u ptáků

    OpenAIRE

    Baránková, Lucie

    2017-01-01

    Hybrid sterility is one of the mechanisms of intrinsic postzygotic reproduction barriers between species and plays a key role in the process of speciation, which is emergence of new species. In accordance with Haldane's rule, hybrid sterility affects preferably the heterogametic sex, which means that in organisms with XY chromosomes, such as mammals or drosophila, male sterility will be affected by sterility of hybrid offspring, while organisms with ZW chromosomes such as birds or butterflies...

  18. Disinfection/sterilization of extracted teeth for dental student use.

    Science.gov (United States)

    Dominici, J T; Eleazer, P D; Clark, S J; Staat, R H; Scheetz, J P

    2001-11-01

    Extracted human teeth are used in many preclinical courses. While there has been no report of disease transmission with extracted teeth, sterilization of teeth used in the teaching laboratory should be a concern. The purpose of this study was to determine the effectiveness of different sterilization/disinfection methods of extracted human teeth using Bacillus stearothermophilus, a bacteria resistant to heat and frequently used to test sterilizers. In this study, 110 extracted molars with no carious lesions were collected and stored in buffered saline. An endodontic occlusal access preparation was cut into the pulp chamber of each tooth. Pulp tissue in the chamber was removed with a broach. Approximately 1 x 10(5) B. stearothermophilus endospores in culture medium were injected into the pulp chamber, sealed with Cavit G, and then placed in sterile saline for twelve hours. Ten teeth were placed into each of eleven groups. Seven groups were immersed for one week in one of the following solutions: a) sterile saline (control group), b) 5.25% NaOCl, c) 2.6% NaOCl, d) 1% NaOCl, e) 10% buffered formalin, f) 2% gluteraldehyde, g) 0.28% quaternary ammonium. Four additional groups were treated by h) 10% formalin for two days, i) 10% formalin for four days, j) autoclaving at 240 degrees F and 20 psi for twenty minutes, and k) autoclaving at 240 degrees F and twenty psi for forty minutes. Each tooth was then aseptically split and placed in an individual test tube with growth medium. Samples were examined for evidence of growth (turbidity) at forty-eight hours. Only autoclaving for forty minutes at 240 degrees F and 20 psi or soaking in 10 percent formalin for one week were 100 percent effective in preventing growth. A chi-square analysis of the data indicates these two methods were significantly better than all other methods (p<0.001).

  19. Acute sterile endophthalmitis following intravitreal bevacizumab: case series

    Science.gov (United States)

    Orozco-Hernández, Axel; Ortega-Larrocea, Ximena; Sánchez-Bermúdez, Gustavo; García-Aguirre, Gerardo; Cantón, Virgilio Morales; Velez-Montoya, Raul

    2014-01-01

    Background Since the ophthalmological community adopted the use of intravitreal bevacizumab as an accepted off-label treatment for neovascular diseases, the amount of knowledge regarding its effects and properties has been increasing continually. In the last few years, there have been an increasing number of reports about sterile intraocular inflammation and intraocular pressure elevations after intravitreal bevacizumab. In the following case series, we describe the clinical presentation and outcomes of ten consecutive cases of patients developing mild-to-severe sterile intraocular inflammation after intravitreal bevacizumab and their management. Methods This report presents a retrospective case series. We reviewed the medical records of ten consecutive patients from a group of 46, in whom repackaged bevacizumab in individual aliquots from two vials from the same batch were used. All surgical procedures were performed using standard sterile techniques in the operating room. At each follow-up visit, patients underwent a complete ophthalmological examination including visual acuity assessment, intraocular pressure, biomicroscopy, and posterior fundus examination. Results Ten patients presented sterile endophthalmitis with an onset time of 3.5±1.95 days. The clinical characteristics were mild pain, slight visual loss, conjunctival hyperemia, and various degrees of intraocular inflammation with microhypopyon. All cultures were negative. All patients were managed with topical steroids and antibiotics, except two, in whom, due to severe vitreous cells, intravitreal antibiotics were used. Three patients showed a transient elevation of intraocular pressure. Only 50% of the patients regained a visual acuity equal or better to the baseline visual acuity on file. Conclusion The increasing number of intravitreal injections of bevacizumab applied every day, due to its widespread acceptance, might be one reason why the number of cases of sterile endophthalmitis is rising. Fast

  20. The effects of inbreeding and heat stress on male sterility in Drosophila melanogaster

    DEFF Research Database (Denmark)

    Pedersen, Louise Dybdahl; Pedersen, Asger Roer; Bijlsma, Kuke

    2011-01-01

    in benign and stressful environments using Drosophila melanogaster as a model organism. Male sterility was compared in 21 inbred lines and five non-inbred control lines at 25.0 and 29.0 °C. The effect of inbreeding on sterility was significant only at 29.0 °C. This stress-induced increase in sterility...

  1. Practical problems in radiation sterilization of medical devices made from plasticized PVC

    International Nuclear Information System (INIS)

    Beenen, J.H.

    1990-01-01

    The following three methods for sterilizing medical devices made from plasticised PVC are used in the Netherlands. 1. sterilization by steam, steam-air or superheated water. 2. sterilization by electron beam or gamma irradiation. 3. ethylene oxide sterilization. IV-bags, blood bags and other bag types for similar applications made from plasticized PVC are mostly sterilized by steam-air or super heated water, especially when filled or partly filled containers are considered. More complicated products or products with components that cannot resist steam sterilization of 121 0 C are sterilized by ethylene oxide or irradiation. These last two methods also are favoured for sterilizing empty bags where sticking of the surfaces at the sterilization temperature creates a serious handicap. Moreover, steam sterilization may cause a permanent opacity of some plastics. However, we have to add that due to developments in formulations steam sterilization of empty bags is going to be of an increasing importance. proven carcinogenity of the gas ethylene oxide, difficult deaeration and retention of the gas in plasticized PVC has increased the demand for better radiation resistant plastics as an alternative for steam sterilization. (author)

  2. Sterilization by Gamma-Radiation of the Sodium Salt of p-Amino-Salicylic Acid

    International Nuclear Information System (INIS)

    Bellion, B.; Denti, E.; Massagli, A.

    1963-01-01

    Sodium p-amino-salicylate cannot be sterilized thermally. During manufacture or packing for medical purposes it must therefore be handled under sterilized conditions, with all the difficulties which this involves. The paper quotes experimental data to show that, using gamma irradiation, the product may be sterilized without damage and without the formation of substances harmful from the medical standpoint. (author) [fr

  3. Sterilization of microorganisms by the supercritical carbon dioxide micro-bubble method.

    Science.gov (United States)

    Ishikawa, H; Shimoda, M; Shiratsuchi, H; Osajima, Y

    1995-10-01

    Lactobacillus brevis and Saccharomyces cerevisiae were completely sterilized by the supercritical (SC) CO2 micro-bubble method. Gaseous (G) and liquid (LQ) CO2 were used in a similar manner to compare the sterilizing effect. Among the three treatments, the microorganisms were only effectively sterilized by the SC CO2 treatment at 25 MPa and 35 degrees C.

  4. Degradation testing of Mg alloys in Dulbecco's modified eagle medium: Influence of medium sterilization.

    Science.gov (United States)

    Marco, Iñigo; Feyerabend, Frank; Willumeit-Römer, Regine; Van der Biest, Omer

    2016-05-01

    This work studies the in vitro degradation of Mg alloys for bioabsorbable implant applications under near physiological conditions. For this purpose, the degradation behaviour of Mg alloys in Dulbecco's modified eagle medium (DMEM) which is a commonly used cell culture medium is analysed. Unfortunately, DMEM can be contaminated by microorganisms, acidifying the medium and accelerating the Mg degradation process by dissolution of protective degradation layers, such as (Mgx,Cay)(PO4)z. In this paper the influence of sterilization by applying UV-C radiation and antibiotics (penicillin/streptomycin) is analysed with two implant material candidates: Mg-Gd and Mg-Ag alloys; and pure magnesium as well as Mg-4Y-3RE as a reference. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Female sterilization in India : The quality and effect of an observed sterilization camp at The Methodist Public Health Centre, Mursan, India

    OpenAIRE

    Wikborg, Pia; Svensk, Marie

    2007-01-01

    Population growth is a big challenge for India, and family planning is highly prioritized by the Government of India. Sterilization is the most common voluntary contraceptive method in India and has for many years been performed in camps. This thesis is based on our observation of a sterilization camp at the Methodist Public Health Centre in Mursan, India and available literature on the subject. We have looked closer at the effect of female sterilization as a method of contraception and t...

  6. Priming of innate antimycobacterial immunity by heat-killed Listeria monocytogenes induces sterilizing response in the adult zebrafish tuberculosis model

    Directory of Open Access Journals (Sweden)

    Hanna Luukinen

    2018-01-01

    Full Text Available Mycobacterium tuberculosis remains one of the most problematic infectious agents, owing to its highly developed mechanisms to evade host immune responses combined with the increasing emergence of antibiotic resistance. Host-directed therapies aiming to optimize immune responses to improve bacterial eradication or to limit excessive inflammation are a new strategy for the treatment of tuberculosis. In this study, we have established a zebrafish-Mycobacterium marinum natural host-pathogen model system to study induced protective immune responses in mycobacterial infection. We show that priming adult zebrafish with heat-killed Listeria monocytogenes (HKLm at 1 day prior to M. marinum infection leads to significantly decreased mycobacterial loads in the infected zebrafish. Using rag1−/− fish, we show that the protective immunity conferred by HKLm priming can be induced through innate immunity alone. At 24 h post-infection, HKLm priming leads to a significant increase in the expression levels of macrophage-expressed gene 1 (mpeg1, tumor necrosis factor α (tnfa and nitric oxide synthase 2b (nos2b, whereas superoxide dismutase 2 (sod2 expression is downregulated, implying that HKLm priming increases the number of macrophages and boosts intracellular killing mechanisms. The protective effects of HKLm are abolished when the injected material is pretreated with nucleases or proteinase K. Importantly, HKLm priming significantly increases the frequency of clearance of M. marinum infection by evoking sterilizing immunity (25 vs 3.7%, P=0.0021. In this study, immune priming is successfully used to induce sterilizing immunity against mycobacterial infection. This model provides a promising new platform for elucidating the mechanisms underlying sterilizing immunity and to develop host-directed treatment or prevention strategies against tuberculosis. This article has an associated First Person interview with the first author of the paper.

  7. Development of the microbiological control aspects of radiation sterilization of medical supplies. Part of a coordinated programme on radiation sterilization of medical and biological products

    International Nuclear Information System (INIS)

    Horakova, V.

    1978-06-01

    The variability and extent of microbial contamination of such medical supplies as hydrophilic gauze swabs and dermo-epidermal grafts were investigated. Gross bacterial contamination was observed in the swabs, with a relative absence of water. It was concluded that medical disposable products under dried aerobic conditions can be sterilized by a minimum dose of 25 kJ/kg/2.5 Mrad if the mean value of pre-sterilization bacterial counts does not exceed 100. Products contaminated by 10,000 or more bacteria prior to sterilization must be considered ''decontaminated'' after irradiation but as rather than ''sterile'', as accepted pharmaceutically. The author recommends that the efficacy of the sterilization dose used be evaluated, assuming the decrease in contaminated items to follow the exponential law, with constants estimated as n=1.98 and k=0.44, and that the sterilization process to be controlled dosimetrically. In general, sub-process doses should be used before actual sterilization by ionizing radiation, in order to estimate the constants characterizing the decrease in contamination under given conditions. In skin grafts a dose of 25 kJ/kg was found to give a high guarantee of sterility. A minimum sterilizing dose of 20 kJ/kg was recommended, provided the mean value of microorganisms on 1 cm 2 of the disinfected and freeze-dried skin grafts from human cadavres was 100, without exceeding an upper limit of 130

  8. Validation of the sterile manufacture of the AAEC MARK III molybdenum-99/techtnetium-99m generator

    International Nuclear Information System (INIS)

    Saunders, M.T.; Drummond, C.M.; Harrison, M.A.

    1982-07-01

    The Mark II molybdenum-99/technetium-99m generator now supplied to hospitals by the Australian Atomic Energy Commission is a non-sterile elution system. The Mark III version will be supplied as a sterile elution system. A validation study has been undertaken to assess the capability of the new production facility, to evaluate up-to-date procedures for manufacturing sterile generators and to demonstrate that a sterile radionuclide generator can be made. Generator manufacturing procedures and a time study of the validation are described. Microbiological methods for monitoring in-process aspects of manufacture, disinfectant efficacy and generator sterility are defined

  9. Application of capacitively coupled rf discharge plasma for sterilization of polymer materials used in ophthalmology

    International Nuclear Information System (INIS)

    Abdullin, I.Sh.; Avetisov, S.E.; Lipatov, D.V.; Rybakova, E.G.; Bragin, V.E.; Bykanov, A.N.; Kamarentsev, E.N.

    1996-01-01

    The sterilization effect of capacitively coupled rf discharge plasma treatment of contact lenses was investigated. There were used two types of polymer: highly hydrophilic polymer with water content 76% (Navelen-76) and poly-methylmethacrylate (PMMA). There was demonstrated the possibility of effective sterilization by RF discharge plasma of a set of polymer materials used in ophthalmology. The best results were obtained for hard contact lenses. There was perfect sterilization in this case. There were not perfect sterilization in some cases of soft contact lenses treatment. It may be caused by porous structure of the external layers of this material and limited thickness of the sterilization layer. (author)

  10. Radiation protection and the female worker

    International Nuclear Information System (INIS)

    Folsom, S.C.

    1983-01-01

    An influx of young women into industrial occupations has resulted in a reexamination of policy regarding fetal protection. Each of the Environmental Protection Agency's four alternatives, as listed in Federal Radiation Protection Guidance for Occupational Exposures, is examined and given a critique: voluntary limitation of radiation exposure to the unborn, voluntary sterilization by women, exclusion of child-bearing-age women from occupational tasks resulting in possible fetal exposure, and limiting the mandatory exposure limit for all workers. The author lists employers and women employees responsibilities in considering occupations with radiation risks. 1 reference

  11. Proposed Philippine radiation-sterilization plant, and a survey of market potential

    International Nuclear Information System (INIS)

    Singson, C.C.; Ibe, L.D.

    1975-01-01

    The paper deals with a study to assess the market potential of radiation sterilization in the Philippines. A market survey conducted with the technical assistance of an IAEA expert from India shows that most of the pharmaceutical industries engaged in the manufacture of medical products unanimously agree that there is an urgent need for a centralized radiation sterilization plant to meet the demands of sterilization of most of their products and packaging materials. The authorities of the government and some of the private hospitals surveyed are also very keen for the establishment of a sterilization facility since most modern medical products and devices are made of heat-sensitive thermoplastics which cannot be heat or steam sterilized. Availability of sterile products will help improve the public health standards of the population. The scope of the utilization of a radiation-sterilization facility in Diliman Quezon City is also discussed. (author)

  12. Multilevel Perspectives on Female Sterilization in Low-Income Communities in Mumbai, India.

    Science.gov (United States)

    Brault, Marie A; Schensul, Stephen L; Singh, Rajendra; Verma, Ravi K; Jadhav, Kalpita

    2016-09-01

    Surgical sterilization is the primary method of contraception among low-income women in India. This article, using qualitative analysis of key informant, in-depth interviews, and quantitative analyses, examines the antecedents, process, and outcomes of sterilization for women in a low-income area in Mumbai, India. Family planning policies, socioeconomic factors, and gender roles constrain women's reproductive choices. Procedures for sterilization rarely follow protocol, particularly during pre-procedure counseling and consent. Women who choose sterilization often marry early, begin conceiving soon after marriage, and reach or exceed ideal family size early due to problems in accessing reversible contraceptives. Despite these constraints, this study indicates that from the perspective of women, the decision to undergo sterilization is empowering, as they have fulfilled their reproductive duties and can effectively exercise control over their fertility and sexuality. This empowerment results in little post-sterilization regret, improved emotional health, and improved sexual relationships following sterilization. © The Author(s) 2015.

  13. Using gamma irradiation to improve sterile turf and forage bermudagrasses

    International Nuclear Information System (INIS)

    Burton, G.W.; Georgia Univ., Tifton

    1976-01-01

    The widely-used Tif-series of turf bermudagrasses - Tifgreen, Tifway, and Tifdwarf - are vegetatively propagated sterile triploids that cannot be improved by conventional breeding methods. Dormant stolons, washed free of soil and cut into one-or two-node sections were treated with varying dosages of EMS (ethyl methane sulfonate) and gamma irradiation ranging from 7 to 12 kR. EMS failed to produce noticeable variants but gamma irradiation from a Cobalt 60 source created 158 mutants. These mutants differed in many characters such as leaf size, hairiness, stem diameter, internode length, basic plant color, herbicide tolerance, spreading rate, and nematode resistance. Attempts to improve the winterhardiness of tetraploid sterile Coastcross-1 forage bermudagrass by exposing over 1,400,000 sprigs (vegetative stems) to 7 kR of gamma rays gave chlorophyll deficient mutants but progress in increasing winterhardiness has not been established. (author)

  14. Role of population genetics in the sterile insect technique

    International Nuclear Information System (INIS)

    Krafsur, E.S.

    2005-01-01

    The detection and analysis of genetic variation in natural and laboratory populations are reviewed. The application of population genetic methods and theory can help to plan and evaluate the implementation of area-wide integrated pest management (AW-IPM) programmes that use the sterile insect technique (SIT). Population genetic studies can play an important role in estimating dispersal rates and thus gene flow among target populations, determining if sibling species exist, establishing the origin of outbreaks or reintroductions, and supporting the quality control of mass-reared colonies. The target's population history may be examined, in terms of 'bottlenecks', range fragmentations, and expansions. Genetic methods can be helpful in distinguishing wild insects from released sterile or substerile ones, and in ascertaining, together with mating cross-compatibility studies, the compatibility of mass-reared colonies with target wild insects. (author)

  15. Suppressing Resistance to Bt Cotton with Sterile Insect Releases

    Energy Technology Data Exchange (ETDEWEB)

    Tabashnik, B E [Department of Entomology, University of Arizona, Tucson, AZ (United States); Sisterson, M S [USDA-ARS, San Joaquin Valley Agricultural Sciences Center, Parlier, CA (United States); Ellsworth, P C [Department of Entomology, University of Arizona, Maricopa Agricultural Center, Maricopa, AZ (United States)

    2011-01-15

    Genetically engineered crops that produce insecticidal toxins from Bacillus thuringiensis (Bt) are grown widely for pest control. However, insect adaptation can reduce the toxins' efficacy. The predominant strategy for delaying pest resistance to Bt crops requires refuges of non-Bt host plants to provide susceptible insects to mate with resistant insects. Variable farmer compliance is one of the limitations of this approach. Here we report the benefits of an alternative strategy where sterile insects are released to mate with resistant insects and refuges are scarce or absent. Computer simulations show that this approach works in principle against pests with recessive or dominant inheritance of resistance. During a largescale, four-year field deployment of this strategy in Arizona, resistance of pink bollworm (Pectinophora gossypiella) to Bt cotton did not increase. A multitactic eradication program that included the release of sterile moths reduced pink bollworm abundance by >99%, while eliminating insecticide sprays against this key invasive pest. (author)

  16. [Juvenile sterile granulomatous dermatitis and lymphadenitis in the dog].

    Science.gov (United States)

    Weingart, C; Eule, C; Welle, M; Kohn, B

    2011-04-01

    Juvenile sterile granulomatous dermatitis and lymphadenitis is a rare immune-mediated skin disease in young dogs. History, signalment, diagnostics, treatment, and outcome in 10 dogs are described. The age ranged from 8 - 36 weeks. The lymph nodes were enlarged in all dogs, especially the mandibular and prescapular lymph nodes. Systemic signs including fever were present in 8 dogs. Seven dogs suffered from blepharitis and painful edema of the muzzle with hemorrhagic discharge, pustules and papules. Cytology of pustules and lymph node aspirates revealed a pyogranulomatous inflammation. In 7 cases the diagnosis of juvenile sterile granulomatous dermatitis and lymphadenitis was confirmed by histology. Nine dogs were treated with prednisolone (0.5 - 1.25 mg/kg BID), H2-receptor antagonists and analgetics; all dogs were treated with antibiotics. Four dogs were treated with eye ointment containing antibiotics and glucocorticoids. The prednisolone dosage was tapered over 3 - 8 weeks. One dog had a relapse.

  17. Search for sterile neutrino mixing using ICAL detector at INO

    International Nuclear Information System (INIS)

    Behera, S.P.; Mohanty, A.K.; Mishra, D.K.; Datar, V.M.; Ghosh, Anushree; Uma Sankar, S.

    2014-01-01

    The phenomena of neutrino (ν) oscillation among three active neutrino flavors (ν e , ν μ , ν τ ) has been established by several neutrino experiments e.g., solar, atmospheric, reactor and accelerator experiments beyond any doubt. However, the results, obtained from the short-baseline experiments, namely LSND, MiniBooNE indicate the possible existence of new kind of ν, different from the three active flavors. Their results cannot be explained within the standard three active ν oscillation formalism and require additional νs with masses at the eV scale. Such νs cannot participate in the weak interaction due to the constraint on invisible width of the Z boson and are therefore called sterile νs. There have been several attempts to interpret the results of LSND and MiniBooNE in terms of 3+N ν oscillation models involving three active νs and N additional sterile νs

  18. Radiation sterilization of enzyme hybrids with biodegradable polymers

    International Nuclear Information System (INIS)

    Furuta, Masakazu; Oka, Masahito; Hayashi, Toshio

    2002-01-01

    Ionizing radiations, which have already been utilized for the sterilization of medical supplies as well as gas fumigation, should be the final candidate to decontaminate 'hybrid' biomaterials containing bio-active materials including enzymes because irradiation induces neither heat nor substances affecting the quality of the materials and our health. In order to check the feasibility of 60 Co-gamma rays on these materials, we selected commercial proteases including papain and bromelain hybridized with commercial activated chitosan beads and demonstrated that these enzyme-hybrids suspended in water showed the significant radiation durability of more than twice as much as free enzyme solution at 25-kGy irradiation. Enhanced thermal and storage stability of the enzyme hybrids were not affected by the same dose level of irradiation, either, indicating that commercial irradiation sterilization method is applicable to enzyme hybrids without modification

  19. Cosmological imprints of frozen-in light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Roland, Samuel B.; Shakya, Bibhushan, E-mail: rolandsa@umich.edu, E-mail: bshakya@umich.edu [Michigan Center for Theoretical Physics, University of Michigan, Ann Arbor, MI 48109 (United States)

    2017-05-01

    We investigate observable cosmological aspects of sterile neutrino dark matter produced via the freeze-in mechanism. The study is performed in a framework that admits many cosmologically interesting variations: high temperature production via annihilation processes from higher dimensional operators or low temperature production from decays of a scalar, with the decaying scalar in or out of equilibrium with the thermal bath, in supersymmetric or non-supersymmetric setups, thus allowing us to both extract generic properties and highlight features unique to particular variations. We find that while such sterile neutrinos are generally compatible with all cosmological constraints, interesting scenarios can arise where dark matter is cold, warm, or hot, has nontrivial momentum distributions, or provides contributions to the effective number of relativistic degrees of freedom N {sub eff} during Big Bang nucleosynthesis large enough to be probed by future measurements.

  20. Ionization radiation in sterilization of the tissue transplants

    International Nuclear Information System (INIS)

    Uhrynowska-Tyszkiewicz, I.; Kaminski, A.

    2007-01-01

    Established in 1963, the Central Tissue Bank in Warsaw is a multi-tissue bank located in the Department of Transplantology of the Medical University in Warsaw. Allografts such as bone, cartilage, tendons, ligaments, sclera, skin and amnion are preserved mainly by deep-freezing and/or lyophilization and subsequently radiation-sterilized with a dose of 35 kGy with gamma rays in a 60 Co source (at the Institute of Applied Radiation Chemistry in Lodz) or with electron beam 10 MeV accelerator (at the Institute of Nuclear Chemistry and Technology in Warsaw). This is the oldest working tissue bank in the world, which for almost 40 years now has routinely used ionizing radiation for sterilization of tissue allografts