WorldWideScience

Sample records for sterile connecting device

  1. Compodock, a new device for sterile docking

    NARCIS (Netherlands)

    van der Meer, P. F.; Biekart, F. T.; Pietersz, R. N.; Rebers, S. P.; Reesink, H. W.

    2000-01-01

    BACKGROUND: A new device for sterile docking, the Compodock (Fresenius NPBI Transfusion Technology), was developed for connecting PVC tubing for medical use while maintaining sterility. STUDY DESIGN AND METHODS: Sterility of the connections was assessed by welding tubing with a heavy exterior

  2. International Standards for Radiation Sterilization of Medical Devices

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    For a terminally sterilized medical device to be designated '' STERILE '', probability of finding the viable micro-organisms in the device shall be equal to or less than 1 x 10 -6 (EN 556-1:2001: Sterilization of medical devices - Requirements for medical devices to be designated '' STERILE '' - Part 1: Requirements for terminally sterilized medical devices). Author presents the main legal aspects of the international standards for radiation sterilization of medical devices

  3. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  4. Prospects of radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari

    1992-01-01

    Since radiation sterilization was first introduced in the United States in 1956 in the field of disposable medical devices, it has become an indispensable technique for sterilization because of the following reasons: (1) introduction into dialyzers, (2) introduction in medical device makers, (3) development of disposable medical devices associated with developing both high molecular chemistry and cool sterilization, (4) rationality of sterilization process, and (5) problems of sterilization with ethylene oxide gas. To promote the further development of radiation sterilization, the following items are considered necessary: (1) an increase in the number of facilities for radiation sterilization, (2) recommendation of the international standardization of sterilization method, (3) decrease in radiation doses associated with sterilization, (4) development of electron accelerators and bremsstrahlung equipments for radiation sources, and (5) simplification of sterilization process management. Factors precluding the development of radiation sterilization are: (1) development of other methods than radiation sterilization, (2) development of technique for sterile products, (3) high facility cost, (4) high irradiation cost, (5) benefits and limits of sterilization markets, and (6) influences of materials. (N.K.)

  5. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  6. Autoclave Sterilization of PEDOT:PSS Electrophysiology Devices.

    Science.gov (United States)

    Uguz, Ilke; Ganji, Mehran; Hama, Adel; Tanaka, Atsunori; Inal, Sahika; Youssef, Ahmed; Owens, Roisin M; Quilichini, Pascale P; Ghestem, Antoine; Bernard, Christophe; Dayeh, Shadi A; Malliaras, George G

    2016-12-01

    Autoclaving, the most widely available sterilization method, is applied to poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) electrophysiology devices. The process does not harm morphology or electrical properties, while it effectively kills E. coli intentionally cultured on the devices. This finding paves the way to widespread introduction of PEDOT:PSS electrophysiology devices to the clinic. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Intracavitary deposits on Essure® hysteroscopic sterilization devices : A case report

    OpenAIRE

    Maassen, L. W.; van Gastel, Maatje D A; Lentjes, E. G.W.M.; Bongers, M. Y.; Veersema, S.

    2017-01-01

    Objective: To study the composition of intracavitary deposits on Essure® hysteroscopic sterilization devices. Design: Case report. Setting: Reproductive Medicine and Gynecology department of a University Hospital. Patient(s): A 39 years old patient presenting with a request for surgical removal of Essure® sterilization devices. Diagnostic hysteroscopy showed a crystal like white deposit attached to one of the devices. Intervention: Diagnostic hysteroscopy and surgical removal of E...

  8. Thixotropic gel-like composition and sterile blood-collecting and separating device

    International Nuclear Information System (INIS)

    Semersky, F.E.

    1980-01-01

    A thixotropic gel-like composition comprising liquid polybutadiene and an inorganic inert filler dispersed therein is adapted for use as a sealing barrier between separated phases of differing densities of a fluid in which said composition has at rest a density intermediate said differing densities, said gel-like composition being substantially resistant to sterilizing radiation. There is also disclosed a pre-packaged blood collecting and separating device which contains a mixture of liquid polybutadiene and an inorganic, inert filler, such as silica, as a thixotropic gel adapted at rest to form a sealing barrier between separated blood phases. The device and gel are subjected to sterilizing radiation to form a substantially sterile device, substantially free of backflow contamination without degradation of the physical properties of the gel. (author)

  9. Sterilization of health care products - Radiation. Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2006-01-01

    A sterile medical device is one that is free of viable microorganisms. International Standards, which specify requirements for validation and routine control of sterilization processes, require, when it is necessary to supply a sterile medical device, that adventitious microbiological contamination of a medical device prior to sterilization be minimized. Even so, medical devices produced under standard manufacturing conditions in accordance with the requirements for quality management systems (see, for example, ISO 13485) may, prior to sterilization, have microorganisms on them, albeit in low numbers. Such medical devices are non-sterile. The purpose of sterilization is to inactivate the microbiological contaminants and thereby transform the nonsterile medical devices into sterile ones. The kinetics of inactivation of a pure culture of microorganisms by physical and/or chemical agents used to sterilize medical devices can generally best be described by an exponential relationship between the numbers of microorganisms surviving and the extent of treatment with the sterilizing agent; inevitably this means that there is always a finite probability that a microorganism may survive regardless of the extent of treatment applied. For a given treatment, the probability of survival is determined by the number and resistance of microorganisms and by the environment in which the organisms exist during treatment. It follows that the sterility of any one medical device in a population subjected to sterilization processing cannot be guaranteed and the sterility of a processed population is defined in terms of the probability of there being a viable microorganism present on a medical device. This part of ISO 11137 describes requirements that, if met, will provide a radiation sterilization process intended to sterilize medical devices, that has appropriate microbicidal activity. Furthermore, compliance with the requirements ensures that this activity is both reliable and

  10. Possibilities of radiation sterilization for re-usage of medical devices in the medical management

    International Nuclear Information System (INIS)

    Tabei, Masae; Kudo, Hisaaki; Katsumura, Yosuke

    2004-01-01

    The rule for re-usage of medical single-use devices was established in US in 2000 based on the concept of Managed Care (total management of medicare on cost, quality and patients' satisfaction) and 20-30% of those devices are re-used at present. The re-usage is conducted in not only US but also Canada, Denmark, UK, India, China etc. Standing on the viewpoint, this paper described and discussed the possibility of re-usage of the single-use devices now prohibited in Japan, possible re-sterilization, possible re-usage of hollow fiber-type hemodialyzer following γ-ray sterilization with consideration for D-values against bacteria and viruses, cost estimation of electron beam sterilization for re-usage, and radiation sterilization of waste water and plastic materials. Radiation sterilization for re-usage of medical devices was concluded possible if their materials and records for their usage processes are proper, and should be conducted in a large scale after sufficient examinations by industries/government/academia. (N.I.)

  11. Effects of Sterilization Cycles on PEEK for Medical Device Application

    Science.gov (United States)

    Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-01-01

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed. PMID:29466289

  12. Effects of Sterilization Cycles on PEEK for Medical Device Application.

    Science.gov (United States)

    Kumar, Amit; Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-02-21

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed.

  13. Development of a new water sterilization device with a 365 nm UV-LED.

    Science.gov (United States)

    Mori, Mirei; Hamamoto, Akiko; Takahashi, Akira; Nakano, Masayuki; Wakikawa, Noriko; Tachibana, Satoko; Ikehara, Toshitaka; Nakaya, Yutaka; Akutagawa, Masatake; Kinouchi, Yohsuke

    2007-12-01

    Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5 alpha, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device.

  14. Effects of sterilization on the mechanical properties of poly(methyl methacrylate) based personalized medical devices.

    Science.gov (United States)

    Münker, T J A G; van de Vijfeijken, S E C M; Mulder, C S; Vespasiano, V; Becking, A G; Kleverlaan, C J; Becking, A G; Dubois, L; Karssemakers, L H E; Milstein, D M J; van de Vijfeijken, S E C M; Depauw, P R A M; Hoefnagels, F W A; Vandertop, W P; Kleverlaan, C J; Münker, T J A G; Maal, T J J; Nout, E; Riool, M; Zaat, S A J

    2018-05-01

    Nowadays, personalized medical devices are frequently used for patients. Due to the manufacturing procedure sterilization is required. How different sterilization methods affect the mechanical behavior of these devices is largely unknown. Three poly(methyl methacrylate) (PMMA) based materials (Vertex Self-Curing, Palacos R+G, and NextDent C&B MFH) were sterilized with different sterilization methods: ethylene oxide, hydrogen peroxide gas plasma, autoclavation, and γ-irradiation. Mechanical properties were determined by testing the flexural strength, flexural modulus, fracture toughness, and impact strength. The flexural strength of all materials was significantly higher after γ-irradiation compared to the control and other sterilization methods, as tested in a wet environment. NextDent C&B MFH showed the highest flexural and impact strength, Palacos R+G showed the highest maximum stress intensity factor and total fracture work. Autoclave sterilization is not suitable for the sterilization of PMMA-based materials. Ethylene oxide, hydrogen peroxide gas plasma, and γ-irradiation appear to be suitable techniques to sterilize PMMA-based personalized medical devices. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Intracavitary deposits on Essure® hysteroscopic sterilization devices: A case report.

    Science.gov (United States)

    Maassen, L W; van Gastel, D M; Lentjes, E G W M; Bongers, M Y; Veersema, S

    2017-07-01

    To study the composition of intracavitary deposits on Essure® hysteroscopic sterilization devices. Case report. Reproductive Medicine and Gynecology department of a University Hospital. A 39 years old patient presenting with a request for surgical removal of Essure® sterilization devices. Diagnostic hysteroscopy showed a crystal like white deposit attached to one of the devices. Diagnostic hysteroscopy and surgical removal of Essure® devices was performed. The deposits were collected and infrared spectroscopy analysis was performed. Chemical composition of the deposits attached to the device. Infrared spectroscopy of the material showed patterns conclusive with calcite (calcium carbonate, CaCO 3 ). Until now, it is not clear if there is a relationship between reported complaints and formation of calcite deposits on Essure®. Infrared spectroscopy of deposits on Essure® devices showed a pattern conclusive with calcite. The relationship between reported complaints and the formation of calcite deposits on Essure® remains unclear.

  16. Evaluation of a new device for sterilizing dental high-speed handpieces

    DEFF Research Database (Denmark)

    Larsen, T; Andersen, H K; Fiehn, N E

    1997-01-01

    Dental high-speed turbines and handpieces can take up and expel microorganisms during operation and thus need regular sterilization. This study established a method for validating devices used to sterilize high-speed turbines and handpieces. The air and water channels and turbine chambers were...... contaminated with suspensions of Streptococcus salivarius or endospores of Bacillus stearothermophilus. The effect of flushing and/or autoclaving performed by a new device combining both procedures was evaluated by counting the number of viable bacteria recovered from these devices. Further, the effect...... on clinically used handpieces was evaluated. In an initial experiment, the device partially reduced S. salivarius, and the endospores survived. In a second experiment, a 5 to 6 log reduction of S. salivarius in air and water channels was obtained. No growth was observed in clinically used high-speed handpieces...

  17. Management of long-term and reversible hysteroscopic sterilization: a novel device with nickel-titanium shape memory alloy

    Science.gov (United States)

    2014-01-01

    Background Female sterilization is the second most commonly used method of contraception in the United States. Female sterilization can now be performed through laparoscopic, abdominal, or hysteroscopic approaches. The hysteroscopic sterilization may be a safer option than sterilization through laparoscopy or laparotomy because it avoids invading the abdominal cavity and undergoing general anaesthesia. Hysteroscopic sterilization mainly includes chemical agents and mechanical devices. Common issues related to the toxicity of the chemical agents used have raised concerns regarding this kind of contraception. The difficulty of the transcervical insertion of such mechanical devices into the fallopian tubes has increased the high incidence of device displacement or dislodgment. At present, Essure® is the only commercially available hysteroscopic sterilization device being used clinically. The system is irreversible and is not effective immediately. Presentation of the hypothesis Our new hysteroscopic sterility system consists of nickel-titanium (NiTi) shape memory alloy and a waterproof membrane. The NiTi alloy is covered with two coatings to avoid toxic Ni release and to prevent stimulation of epithelial tissue growth around the oviducts. Because of the shape memory effect of the NiTi alloy, the device works like an umbrella: it stays collapsed at low temperature before placement and opens by the force of shape memory activated by the body temperature after it is inserted hysteroscopically into the interstitial tubal lumen. The rim of the open device will incise into interstitial myometrium during the process of unfolding. Once the device is fixed, it blocks the tube completely. When the patient no longer wishes for sterilization, the device can be closed by perfusing liquid with low temperature into the uterine cavity, followed by prospective hysteroscopic removal. After the device removal, the fallopian tube will revert to its physiological functions. Testing the

  18. Practical problems in radiation sterilization of medical devices made from plasticized PVC

    International Nuclear Information System (INIS)

    Beenen, J.H.

    1990-01-01

    The following three methods for sterilizing medical devices made from plasticised PVC are used in the Netherlands. 1. sterilization by steam, steam-air or superheated water. 2. sterilization by electron beam or gamma irradiation. 3. ethylene oxide sterilization. IV-bags, blood bags and other bag types for similar applications made from plasticized PVC are mostly sterilized by steam-air or super heated water, especially when filled or partly filled containers are considered. More complicated products or products with components that cannot resist steam sterilization of 121 0 C are sterilized by ethylene oxide or irradiation. These last two methods also are favoured for sterilizing empty bags where sticking of the surfaces at the sterilization temperature creates a serious handicap. Moreover, steam sterilization may cause a permanent opacity of some plastics. However, we have to add that due to developments in formulations steam sterilization of empty bags is going to be of an increasing importance. proven carcinogenity of the gas ethylene oxide, difficult deaeration and retention of the gas in plasticized PVC has increased the demand for better radiation resistant plastics as an alternative for steam sterilization. (author)

  19. Device and Container for Reheating and Sterilization

    Science.gov (United States)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  20. Cybersecurity for Connected Diabetes Devices.

    Science.gov (United States)

    Klonoff, David C

    2015-04-16

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. © 2015 Diabetes Technology Society.

  1. Medicine Delivery Device with Integrated Sterilization and Detection

    Science.gov (United States)

    Shearn, Michael J.; Greer, Harold F.; Manohara, Harish

    2013-01-01

    Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. The application of semiconductor processing techniques and technologies to the problems of fluid manipulation and delivery has enabled the integration of chemical, electrical, and mechanical manipulation of samples all within a single microfluidic device. This approach has been successfully applied at JPL to the automated processing, detection, and analysis of minute quantities (parts per trillion level) of biomaterials to develop instruments for in situ exploration or extraterrestrial bodies. The same nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely high-surface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL's ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization

  2. Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2007-01-01

    This part of ISO 11135 describes requirements that, if met, will provide an ethylene oxide sterilization process intended to sterilize medical devices, which has appropriate microbicidal activity. Furthermore, compliance with the requirements ensures that this activity is both reliable and reproducible so that it can be predicted, with reasonable confidence, that there is a low level of probability of there being a viable microorganism present on product after sterilization. Specification of this probability is a matter for regulatory authorities and may vary from country to country. The paper provides information on scope, normative references, terms and definitions, quality management systems, sterilizing agent characterization, process and equipment characterization, product definition, process definition, validation, routine monitoring and control, product release from sterilization and maintaining process effectiveness followed by Annex A (Determination of lethal rate of the sterilization process - Biological indicator/bioburden approach), Annex B (Conservative determination of lethal rate of the sterilization process - Overkill approach, annex C (General guidance) and a bibliography.

  3. Microbiological Load Of Ethylene Oxide Sterilized Medical Devices And Its Elimination By Cobalt 60 Source

    International Nuclear Information System (INIS)

    Bashir, R.; Afroze, B.; Zulfiqar, H. F.; Saleem, R.; Saleem, F.; Aslam, F.; Naz, S.

    2016-01-01

    Objective: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. Study Design: Experimental study. Place and Duration of Study: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. Methodology: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). Result: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus and Bacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations Result showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. Conclusion: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices. (author)

  4. Intracavitary deposits on Essure® hysteroscopic sterilization devices : A case report

    NARCIS (Netherlands)

    Maassen, L. W.; van Gastel, Maatje D A; Lentjes, E. G.W.M.; Bongers, M. Y.; Veersema, S.

    2017-01-01

    Objective To study the composition of intracavitary deposits on Essure® hysteroscopic sterilization devices. Design Case report. Setting Reproductive Medicine and Gynecology department of a University Hospital. Patient(s) A 39 years old patient presenting with a request for surgical removal of

  5. Practical aspects during sterilization validation for medical devices at IRASM Microbiological Laboratory

    International Nuclear Information System (INIS)

    Trandafir, L.; Ene, M.; Alexandru, M.; Constantin, M.; Ionita, A.; Zorila, F.; Moise, I.V.

    2011-01-01

    Complete text of publication follows. The state of being free of living microorganisms is called sterility. The sterility state can be achieved by different means of sterilization. In practice the results of the process cannot be fully verified by tests, so the efficacy of the sterilization process must be validated. ISO 11137 established regulations for setting or substantiating the dose for achieving the desired sterility assurance level. The validation studies can be designed in particular for different types of product. Each product needs distinct protocol for bioburden determination and sterility testing. During time, the Microbiological Laboratories from Multipurpose Irradiation Center deals with different types of products, mainly for VD max 25 method. When it comes to microbiological evaluation the most challenging was cotton gauze. Special situation for establishing the sterilization validation method appears in cases of cotton, packed in large quantities. VD max 25 method can not be applied for items with average bioburden more than 1000 CFU / pack, no matter which is the weight of the package. This is a method limitation and implies increased costs for manufacturer, when choosing other method. For microbiological tests, culture condition should be selected in both cases the bioburden and sterility testing. These are time and money consuming. The costs can be reduced if taking into account some aspects. Reason for performing the bacteriostasis-fungistasis just for sterility testing will be given. The present study puts forward aspects during the validation studies for medical devices (cotton wool, cotton gauze, surgical sutures, dental screws), at IRASM Microbiological Laboratory.

  6. What do you mean you can't sterilize it? The reusable medical device matrix.

    Science.gov (United States)

    Stephens, Anne; Assang, AnnMarie

    2010-12-01

    Health Canada recommends that hospitals should have procedures in place to ensure Reusable Medical Devices (RMD) are cleaned, disinfected and sterilized according to the manufacturer's instructions. For the purpose of this paper, reusable medical devices will be referred to as RMDs and include all instrumentation and devices that the Central Processing Department (CPD) resterilizes for use in the hospital. Patient safety in surgery begins in CPD. Manufacturer recommendations for the decontamination and sterilization of surgical instrumentation are of utmost importance to Operating Room (OR) and CPD staff. With recommendations that are unclear, nonspecific or unattainable there was a need to define what it means institutionally to meet standards and provide safe patient care while continuing to support the advancement of surgical technology. The purpose of this paper is to describe the challenges faced by one multisite organization (The University Health Network) in managing the sterilization of surgical instrumentation. The development of The Guidance Matrix by the network's inter-professional Reusable Medical Device (RMD) Committee, will be discussed along with information about the elements of this tool and an illustration of how it is used. The key benefits of The Guidance Matrix, including how its use has facilitated transparent decision-making, communication and collaboration regarding sterilization issues across the sites, will be described. Sterilization processes in Central Processing Departments (CPD) include chemical indicators, dated load indicators, and tamperproof locks and filters. The lack of an indicator of sterilization can be a frustrating experience for an OR Nurse. But do we really understand the critical importance of all these indicators? The foundation of sterilizing reusable medical devices (RMDs) begins with proper processes, standards and subsequent scientific validation from the vendors. According to AORN, patient safety is vital and it

  7. Currently available devices for female sterilization.

    Science.gov (United States)

    Chapman, Lynne; Magos, Adam

    2005-09-01

    Sterilization is now the method of family planning most commonly used in the world. Over the last 150 years, research has evolved in the search for the ideal method of female sterilization. The procedure should ideally have high efficacy, be readily accessible and be personally and culturally acceptable. The method should be simple, quick, easily learned and be able to be performed in an outpatient setting without general anesthesia. The most common and effective method for sterilization has, thus far, been via the laparoscopic route. Hysteroscopic sterilization, however, potentially fulfills many of these ideal criteria, but until recently has remained more of a concept than a reality.

  8. Wireless device connection problems and design solutions

    Science.gov (United States)

    Song, Ji-Won; Norman, Donald; Nam, Tek-Jin; Qin, Shengfeng

    2016-09-01

    Users, especially the non-expert users, commonly experience problems when connecting multiple devices with interoperability. While studies on multiple device connections are mostly concentrated on spontaneous device association techniques with a focus on security aspects, the research on user interaction for device connection is still limited. More research into understanding people is needed for designers to devise usable techniques. This research applies the Research-through-Design method and studies the non-expert users' interactions in establishing wireless connections between devices. The "Learning from Examples" concept is adopted to develop a study focus line by learning from the expert users' interaction with devices. This focus line is then used for guiding researchers to explore the non-expert users' difficulties at each stage of the focus line. Finally, the Research-through-Design approach is used to understand the users' difficulties, gain insights to design problems and suggest usable solutions. When connecting a device, the user is required to manage not only the device's functionality but also the interaction between devices. Based on learning from failures, an important insight is found that the existing design approach to improve single-device interaction issues, such as improvements to graphical user interfaces or computer guidance, cannot help users to handle problems between multiple devices. This study finally proposes a desirable user-device interaction in which images of two devices function together with a system image to provide the user with feedback on the status of the connection, which allows them to infer any required actions.

  9. NF EN ISO 11137-1, July 2006. Sterilization of health care products - Irradiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2006-01-01

    This part of the ISO 11137 standard specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices. Although the scope of this part of the ISO 11137 standard is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other products and equipment. This part of the international standard covers radiation processes employing irradiators using the radionuclide 60 Co or 137 Cs, a beam from an electron generator or a beam from an X-ray generator. This part of the international standard does not: - specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease; - detail specified requirements for designating a medical device as sterile; - specify a quality management system for the control of all stages of production of medical devices; - specify requirements for occupational safety associated with the design and operation of irradiation facilities; - specify requirements for the sterilization of used or reprocessed devices

  10. Hysteroscopic sterilization of patient with intrauterine device Mirena®

    Science.gov (United States)

    Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Yatabe, Salete; Lopes, Reginaldo Guedes Coelho

    2013-01-01

    ABSTRACT Tubal sterilization is the definitive procedure most often used worldwide to control fecundity. Laparoscopic ligature is safe, but invasive and with possible surgical and anesthetic risks. The hysteroscopic approach enables tubal occlusion at outpatient's setting without the need of incisions or anesthesia. A microdevice (Essure®) is inserted directly into the tubes and its polyethelene fibers cause obstruction of tubes in about three months. During this period, it is recommended that patients continue the use of a temporary birth control method. Several women use the levonorgestrel-releasing intrauterine system, which is called in the market as Mirena®. This report evaluated the possibility of inserting Essure® without remove the intrauterine device; patient tolerance to the procedure was also assessed. The tubal device was successfully placed in the patient without the need to remove Mirena®. After three months the intrauterine device was removed with no intercurrent events. PMID:23579753

  11. Analysis of adverse events with Essure hysteroscopic sterilization reported to the Manufacturer and User Facility Device Experience database.

    Science.gov (United States)

    Al-Safi, Zain A; Shavell, Valerie I; Hobson, Deslyn T G; Berman, Jay M; Diamond, Michael P

    2013-01-01

    The Manufacturer and User Facility Device Experience database may be useful for clinicians using a Food and Drug Administration-approved medical device to identify the occurrence of adverse events and complications. We sought to analyze and investigate reports associated with the Essure hysteroscopic sterilization system (Conceptus Inc., Mountain View, CA) using this database. Retrospective review of the Manufacturer and User Facility Device Experience database for events related to Essure hysteroscopic sterilization from November 2002 to February 2012 (Canadian Task Force Classification III). Online retrospective review. Online reports of patients who underwent Essure tubal sterilization. Essure tubal sterilization. Four hundred fifty-seven adverse events were reported in the study period. Pain was the most frequently reported event (217 events [47.5%]) followed by delivery catheter malfunction (121 events [26.4%]). Poststerilization pregnancy was reported in 61 events (13.3%), of which 29 were ectopic pregnancies. Other reported events included perforation (90 events [19.7%]), abnormal bleeding (44 events [9.6%]), and microinsert malposition (33 events [7.2%]). The evaluation and management of these events resulted in an additional surgical procedure in 270 cases (59.1%), of which 44 were hysterectomies. Sixty-one unintended poststerilization pregnancies were reported in the study period, of which 29 (47.5%) were ectopic gestations. Thus, ectopic pregnancy must be considered if a woman becomes pregnant after Essure hysteroscopic sterilization. Additionally, 44 women underwent hysterectomy after an adverse event reported to be associated with the use of the device. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  12. Unilateral placement of the Adiana device after failed bilateral placement of the Essure device for hysteroscopic sterilization.

    Science.gov (United States)

    Gimpelson, Richard J; Wagner, Corey A

    2010-01-01

    This case report outlines the successful completion of hysteroscopic sterilization using the Adiana Permanent Contraception device (Hologic, Inc., Bedford, MA) after failure of multiple attempts to bilaterally place the Essure Permanent Birth Control system (Conceptus Inc., Mountain View, CA). The patient desired hysteroscopic sterilization using the Essure system. Although the first coil was easily placed in the right ostium, the second coil could not be passed beyond 2.4 cm into the left ostium. Inasmuch as the Adiana system needs to be passed only 1.4 cm into the ostium, this was found to be adequate for appropriate placement of the implant. Adiana may be an effective alternative to Essure, especially in patients in whom tubal stricture or spasm prevents Essure placement. Copyright © 2010 AAGL. Published by Elsevier Inc. All rights reserved.

  13. Ozone--the latest advance in sterilization of medical devices.

    Science.gov (United States)

    Murphy, Lorna

    2006-06-01

    How many times have procedures in your operating rooms been delayed because the instruments needed were still in the sterilizer? As Perioperative nurses you are likely to be quite familiar with the constant pressure to ensure that scarce instrumentation is available when needed. In 2003, a Canadian company developed a unique sterilization process employing ozone as the sterilizing agent. This technology is a safe, rapid and economical alternative to other low temperature sterilization modalities and may relieve some of the pressure experienced when instruments in short supply are in high demand. This article will discuss the principles of the sterilizer and the cycle and will explore the advantages of using this sterilization technology.

  14. Steam sterilization does not require saturated steam

    NARCIS (Netherlands)

    van Doornmalen Gomez Hoyos, J. P.C.M.; Paunovic, A.; Kopinga, K.

    2017-01-01

    The most commonly applied method to sterilize re-usable medical devices in hospitals is steam sterilization. The essential conditions for steam sterilization are derived from sterilization in water. Microbiological experiments in aqueous solutions have been used to calculate various time–temperature

  15. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to...

  16. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

    Science.gov (United States)

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter

    2015-01-01

    Objective To compare the safety and efficacy of hysteroscopic sterilization with the “Essure” device with laparoscopic sterilization in a large, all-inclusive, state cohort. Design Population based cohort study. Settings Outpatient interventional setting in New York State. Participants Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Main outcomes measures Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. Results We identified 8048 patients undergoing hysteroscopic sterilization and 44 278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Conclusions Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures

  17. [Hysteroscopic tubal sterilization with Essure® devices: a retrospective descriptive study and evaluation of hypnosis].

    Science.gov (United States)

    Gauchotte, E; Masias, C; Bogusz, N; Koebele, A

    2011-06-01

    The Essure(®) system is a hysteroscopic sterilization method. The aim of our study is to retrospectively evaluate the sterilization procedure with Essure(®) devices, with and without anesthesia, and in particular with hypnosis. The descriptive study includes all tubal sterilization with Essure(®) performed during the year 2009 at the Maternité régionale de Nancy. Hypnosis efficiency is retrospectively evaluated with Verbal Numeric Rating Scale (VNRS) for peroperative pain, and analgesic medication use for postoperative pain. Ninety-four sterilizations are performed, 85% (85/94) of them without anesthesia. The mean VNRS is 3.0. The mean operative time is 8.7 minutes, positively correlated with the VNRS (P=0.0005). The rate of successful insertion is 94%. At 3 months, 91% of the implants have a correct location. Inadequate locations are more frequent when anesthesia have been performed (37% vs 4%, P=0.016). There is no significant difference between groups with and without hypnosis for the VNRS, the failure rate and the use of analgesic medication. Tubal sterilization with the Essure(®) system is a quick and efficient method. Our study does not demonstrate efficiency of hypnosis in pain control. This remains to be explored with a prospective study, including others parameters, such as anxiety. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  18. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  19. Pre-sterilization contamination of disposable medical products and the choice of minimum sterilization dose

    International Nuclear Information System (INIS)

    Horakova, V.; Buriankova, E.

    1975-01-01

    The bacterial contamination was assessed on randomly taken samples of blood-transfusion devices, donor sets, intra-uterine contraceptive devices and inserters, surgical gloves and dressing material prior to sterilization. The quantitative and qualitative efficiency of six nutrient media was compared. The best results were obtained with the enriched ''Universal'' medium. It was confirmed that the contamination of plastic products was low compared with dressing material. Most frequently, Gram-positive aerobic spore-forming rods and Gram-positive cocci were found on non-sterile medical disposable products. A method was tested to obtain a general informative picture of the resistance of bacteria on products. The methods used for choosing the dose for radiation sterilization of medical products are discussed. (author)

  20. Gamma-ray irradiation, autoclave and ethylene oxide sterilization to thermosetting polyurethane: sterilization to polyurethane

    International Nuclear Information System (INIS)

    Hirata, Noriko; Matsumoto, Ken-Ichi; Inishita, Takashi; Takenaka, Yoshinori; Suma, Yasunori; Shintani, Hideharu; National Inst. of Health Sciences, Tokyo

    1995-01-01

    Thermosetting polyurethane (PU) is widely used in a large variety of medical devices. 4,4'-methylenedianiline (MDA) was produced from PU by sterilization and it was studied for the relationship between urethane components or polymer characteristics and formation of MDA upon sterilization, using the commercially available dialyzers fabricated with different combination of isocyanate and polyol. We confirmed that the molecular-weight of polyol influenced the production of MDA upon sterilization. (author)

  1. Radiosterilization and gas sterilization

    International Nuclear Information System (INIS)

    Schultz, H.A.; Gruenewald, T.

    1987-01-01

    The book presents a survey of the principles of cold sterilization by radiation or gas, and also of the problems involved. The reader who has to do with sterilization of some kind or other, as e.g. sterilization of medicaments, medical supplies, medical device, drugs, grafts, or food, will find comprehensive information on the various available methods and their effects, as well as on monitoring procedures and techniques, together with proposals for efficient documentation and validation of partial sterilization processes. The introduction summarizes the potentials of sterilization by radiation, and the subsequent by radiation, and the subsequent chapters explain the specific applicabilities of radiosterilization along with the most important criteria for evaluating the sterilizing efficiency. The information on the legal situation and requirements takes into account the second amendment of the Medical Preparations Act. With 38 figs., 14 tabs [de

  2. Modular ionizing sterilizer (MIS)

    International Nuclear Information System (INIS)

    Freijo, Jose L.

    1999-01-01

    A transportable device designed to sterilize medical material and wastes by gamma irradiation is described. The sterilizer is formed by three modules: one of the modules contains the gamma source and can be removed to transport and transfer the source, the other modules are designed to introduce and draw out the materials to be irradiated

  3. The effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices for dental implants

    Directory of Open Access Journals (Sweden)

    Ali Fayaz

    2014-01-01

    Full Text Available Background: Mechanical torque limiting devices (MTLDs are necessary tools to control a peak torque and achieving target values of screw component of dental implants. Due to probable effect of autoclaving and number of use on the accuracy of these devices, this study aimed to evaluate the effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices (F-S MTLDs in achieving their target torque values. Materials and Methods: Peak torque measurements of 15 new F-S MTLDs from three different manufacturers (Astra Tech, BioHorizons, Dr. Idhe were measured ten times before and after 100 steam sterilization using a digital torque gauge. To simulate the clinical situation of aging (number of use target torque application process was repeated 10 times after each sterilization cycle and the peak torque values were registered. Comparison of the mean differences with target torque in each cycle was performed using one sample t test. Considering the type of MTLDs as inter subject comparison, One-way repeated measure ANOVA was used to evaluate the absolute values of differences between devices of each manufacturer in each group (α = 0.05. Results: The results of this study in Dr. Idhe group showed that, mean of difference values significantly differed from the target torque (P = 0.002 until 75 cycles. In Astra Tech group, also mean of difference values with under estimation trend, showed a significant difference with the target torque (P < 0.001. Mean of difference values significantly differed from the target torque with under estimation trend during all the 100 cycles in BioHorizons group (P < 0.05. Conclusion: The torque output of each individual device stayed in 10% difference from target torque values before 100 sterilization cycles, but more than 10% difference from the target torque was seen in varying degrees during these consequent cycles.

  4. Cleaning, Disinfection, and Sterilization Protocols Employed for Customized Implant Abutments: An International Survey of 100 Universities Worldwide.

    Science.gov (United States)

    Canullo, Luigi; Tallarico, Marco; Chu, Stephen; Peñarrocha, David; Özcan, Mutlu; Pesce, Paolo

    American and European standards recommend sterilization of customized abutments before connecting them to implants, as customized abutments are considered semi-critical medical devices. Since standardized procedures could not be identified in the literature on implantology, this survey evaluated the protocols employed at different universities worldwide to clean, disinfect, and/or sterilize customized abutments before their connection to bone-level implants. The survey took place between October 2015 and January 2016. A single question acquiring information on how customized abutments were treated prior to connection to the implants was sent by email to researchers affiliated at 100 universities worldwide. To avoid any bias, the survey was kept rigorously anonymous. A total of 100 universities from Europe (56), USA and Canada (25), Latin America (9), South Africa (1), Asia (6), and Australia and New Zealand (3) were invited to participate in the survey. Altogether, 85 universities responded to the survey question, and 22 (25.9%) declared that no cleaning protocols were adopted. More than half of the respondents (n = 49, 57.6%) performed only one of the three procedures required by the standards (cleaning, disinfection, or sterilization). Twelve respondents (14.1%) adopted two procedures, and only two universities performed all three required procedures (2.4%). This survey indicated substantial heterogeneity in treating customized abutments before connecting them to implants. This study demonstrated that the majority of the universities applied either cleaning, disinfection, or sterilization which may not meet the prevailing standards.

  5. Development of atmospheric pressure plasma needle jet for sterilization applications

    Science.gov (United States)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Soon, Chin Fhong; Sahdan, Mohd Zainizan; Lias, Jais; Wibowo, Kusnanto Mukti; Bakar, Ahmad Shuhaimi Abu; Arshad, Mohd Khairuddin Md; Hashim, Uda; Nayan, Nafarizal

    2017-09-01

    Inactivation of bacteria or sterilization has been a major issue in the medical field, especially regarding of human safety, whereby, in a huge scenario fatality can be caused by hazardous bacteria. Often, E-coli as gram-negative bacteria are selected as a key indicator of proper sterilization process as E-coli is tough and dormant bacteria. The technology in sterilization has moved on from chemical, wet and irradiation sterilization to a high promising device such as atmospheric pressure plasma needle jet (APPNJ). It has been reported that atmospheric pressure plasma has provided bundle of advantages over earlier sterilization process. The APPNJ is developed in our lab using high frequency and high voltage neon transformer power supply connected to copper needle and copper sheet electrodes. The gas discharge is Ar gas flowing at 40 L/min through a quartz glass tube. The E-coli bacteria are self-cultured from waste water and then treated with APPNJ. The treatment processes are run into two difference gaps between the plasma orifice and sample with various treatment times. Only 40s is required by direct treatment to achieve 100% killing of E-coli. On the other hand, indirect treatment has inactivated 50% of the E-coli in 40s. In this study, direct and indirect effect of APPNJ to the E-coli can be observed which can be utilized into sterilization of bio-compatible material applications.

  6. Mobile medical device connectivity: real world solutions.

    Science.gov (United States)

    Pettus, Dan

    2004-01-01

    Mobile medical devices, such as infusion pumps, provide an important therapeutic function. They are also valuable sources of information about treatment patterns at the point of care. However, these mobile devices have been independent islands of valuable information, unable to share the data they gather with other hospital information resources on a real time basis. Although data from these devices can provide significant improvements for medical safety and vital information needed for clinical best practice development, gathering that data poses significant challenges when interfacing with hospital information systems. Mobile medical devices move from place to place as independent actors, raising a series of security and identification issues when they need to be disconnected and reconnected using traditional tethered cable connections. The continuing lack of accepted communications protocol standards, in spite of the concentrated efforts of organizations like the IEEE and the Medical Information Bus (IEEE 1073) to establish them, has made integration into the hospital information system a complex and non-standard task. The rapid spread in availability and adoption of high-speed 802.11 wireless systems in hospitals offers a realistic connectivity solution for mobile medical devices. Inspite of this, the 802.11 standard is still evolving, and current security methods designed for user-based products like PDAs and laptop computers are not ideal for unmanned mobile medical devices because they assume the availability of a human operator to authenticate a wireless session. In the absence of accepted standards, manufacturers have created practical and innovative solutions to support the collection of clinical data from mobile medical devices and the integration of that data with hospital information systems. This paper will explore the potential benefits of integrating mobile medical devices into the hospital information system, and describe the challenges in

  7. Radiation sterilization of medical products- current trends and future prospects

    International Nuclear Information System (INIS)

    Sharma, G.

    1997-01-01

    In medical practice use of sterile pharmaceuticals and single use disposable medical devices is steadily increasing. Sterile pharmaceuticals like injections and ophthalmic ointments are required for therapy. Medical devices are employed for diagnostic, drug administration or corrective purposes, and as implants for temporary, short term or long term residence in the human system. All these products are made available in sterile form by treating them to a suitable process of sterilization i.e. dry/wet heat, ethylene oxide (EtO) gas or ionizing radiation. In this paper current trends and future prospects of radiation sterilization of medical products are given in detail. 9 refs., 7 tabs

  8. Dynamic sterilization of titanium implants with ultraviolet light

    International Nuclear Information System (INIS)

    Singh, S.; Schaaf, N.G.

    1989-01-01

    All implantable devices must be sterile. However, autoclaves produce poor surface properties that jeopardize the integration process. The application of a modified ultraviolet light source has proven to enhance bioreactivity by controlling surface properties, but it lacks validation of its sterilization capabilities. Forty-eight titanium implants were contaminated with spores of the biological indicator Bacillus stearothermophilus and subjected to dynamic sterilization by ultraviolet light. Forty-seven of the implants were successfully sterilized, as indicated by not producing turbidity in a suitable growth medium. This sterilization technique only requires a 20-second exposure to achieve sterility

  9. Sterilization by ionizing radiation comparative evaluation

    International Nuclear Information System (INIS)

    Tata, A.; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 7 on beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems

  10. Sterilization validation for medical compresses at IRASM multipurpose irradiation facility

    International Nuclear Information System (INIS)

    Alexandru, Mioara; Ene, Mihaela

    2007-01-01

    In Romania, IRASM Radiation Processing Center is the unique supplier of radiation sterilization services-industrial scale (ISO 9001:2000 and ISO 13485:2003 certified). Its Laboratory of Microbiological Testing is the sole third party competent laboratory (GLPractice License, ISO 17025 certification in progress) for pharmaceutics and medical devices as well. We here refer to medical compresses as a distinct category of sterile products, made from different kind of hydrophilic materials (cotton, non-woven, polyurethane foam) with or without an impregnated ointment base (paraffin, plant extracts). These products are included in the class of medical devices, but for the sterilization validation, from microbiological point of view, there are important differences in testing method compared to the common medical devices (syringes, catheters, etc). In this paper, we present some results and practical solutions chosen to perform a sterilization validation, compliant with ISO 11137: 2006

  11. Challenges in validating radiation sterilization with low energy electron irradiation

    International Nuclear Information System (INIS)

    Miller, A.; Helt-Hansen, J.

    2011-01-01

    Complete text of publication follows. Low energy electron irradiation (80-300 keV) is used increasingly for sterilization or decontamination in connection with isolators for aseptic filling lines in the pharmaceutical industry. It is not defined how validation for this process shall be carried out. A method can be derived from the medical device standard for radiation sterilization, ISO 11137, because the principles described in this standard can be applied to almost any industrial irradiation process. The validations elements are: Process definition, concerning specification of the dose required for the process and the maximum acceptable dose for the product. Installation qualification, concerning acceptance the irradiation facility. Operational qualification, concerning characterization of the facility. Performance qualification, concerning setting up the process. Process control, concerning routine monitoring. The limited penetration of the low energy electrons leads to problems with respect to executing these validation steps. This paper discusses these problems, and shows with examples how they can be solved.

  12. Sterilization validation for medical devices at IRASM microbiological laboratory—Practical approaches

    International Nuclear Information System (INIS)

    Trandafir, Laura; Alexandru, Mioara; Constantin, Mihai; Ioniţă, Anca; Zorilă, Florina; Moise, Valentin

    2012-01-01

    EN ISO 11137 established regulations for setting or substantiating the dose for achieving the desired sterility assurance level. The validation studies can be designed in particular for different types of products. Each product needs distinct protocols for bioburden determination and sterility testing. The Microbiological Laboratory from Irradiation Processing Center (IRASM) deals with different types of products, mainly for the VD max 25 method. When it comes to microbiological evaluation the most challenging was cotton gauze. A special situation for establishing the sterilization validation method appears in cases of cotton packed in large quantities. The VD max 25 method cannot be applied for items with average bioburden more than 1000 CFU/pack, irrespective of the weight of the package. This is a method limitation and implies increased costs for the manufacturer when choosing other methods. For microbiological tests, culture condition should be selected in both cases of the bioburden and sterility testing. Details about choosing criteria are given. - Highlights: ► The paper presents aspects and results within the sterilization validation process. ► Critical aspects that can lead to the failure of the process were emphasized. ► Limitation methods were discussed.

  13. Insecure Network, Unknown Connection: Understanding Wi-Fi Privacy Assumptions of Mobile Device Users

    Directory of Open Access Journals (Sweden)

    Bram Bonné

    2017-07-01

    Full Text Available Smartphones and other mobile devices have proliferated in the past five years. The expectation of mobile device users to always be online has led to Wi-Fi networks being offered by a variety of providers. Using these networks introduces multiple security risks. In this work, we assess to what extent the privacy stance of mobile device users corresponds with their actual behavior by conducting a study with 108 participants. Our methodology consists of monitoring Wi-Fi networks that the participants’ devices connect to and the connections made by apps on these devices, for a period of 30 days. Afterwards, participants are surveyed about their awareness and privacy sensitiveness. We show that while a higher expertise in computer networks corresponds to more awareness about the connections made by apps, neither this expertise nor the actual privacy stance of the participant translates to better security habits. Moreover, participants in general were unaware about a significant part of connections made by apps on their devices, a matter that is worsened by the fact that one third of Wi-Fi networks that participants connect to do not have any security enabled. Based on our results, we provide recommendations to network providers, developers and users on how to improve Wi-Fi security for mobile devices.

  14. Radiation sterilization of some pharmaceutical preparations and medical products

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Makhkamov, Sh.M.; Urinov, Sh.S.; Turaev, A.S.; Sultanov, M.S.; Inagomov, Kh.S.

    2006-01-01

    Full text: In connection with intensive development of pharmacology and medical techniques, use of the products contacting to blood, with the internal environment of an organism, with wound surface, with mucous membranes and skin there were high requirements to sterility of pharmaceutical preparations and medical products. Traditional methods of sterilization (heat treatment, gas processing and processing the ferry) have some restrictions in application, and not insufficient degree of sterilization required for pharmaceutical preparations and medical products. Thermal processing can lead to degradation of structure (medicine), mechanical changes and loss of medical properties. Besides, it is impossible to carry out sterilization of many pharmaceutical preparations by a method of heat treatment. Sterilization of products in packing is very complicated, because sterilization temperature of packing and a product is different. Gas processing is basically applied to sterilization of medical products (syringes, bandage, cotton wools, etc.). However, the degree of sterility is low, because of rather low ability and heterogeneity of sterilizing substance. Sterilization in packing represents special difficulty and demands additional charges related with delivery of the purified gas from abroad. Last years alongside with known technological methods of sterilization of medical products and pharmaceutical preparations radiating methods of processing have found wide application. Use of electronic bunches with the moderate energy and various isotopes became a basis for formation and development of a new direction in the medicine, called by 'radiation sterilization'. The radiation technology is highly harmless and economic, not polluting substance and surrounding space. Unlike the specified traditional methods, radiating processing of products by the isotope 60 Co, radiating the gamma quantum, has unique opportunities - high penetrability in substance, providing uniformity of

  15. Sterilization validation for medical devices at IRASM microbiological laboratory—Practical approaches

    Science.gov (United States)

    Trandafir, Laura; Alexandru, Mioara; Constantin, Mihai; Ioniţă, Anca; Zorilă, Florina; Moise, Valentin

    2012-09-01

    EN ISO 11137 established regulations for setting or substantiating the dose for achieving the desired sterility assurance level. The validation studies can be designed in particular for different types of products. Each product needs distinct protocols for bioburden determination and sterility testing. The Microbiological Laboratory from Irradiation Processing Center (IRASM) deals with different types of products, mainly for the VDmax25 method. When it comes to microbiological evaluation the most challenging was cotton gauze. A special situation for establishing the sterilization validation method appears in cases of cotton packed in large quantities. The VDmax25 method cannot be applied for items with average bioburden more than 1000 CFU/pack, irrespective of the weight of the package. This is a method limitation and implies increased costs for the manufacturer when choosing other methods. For microbiological tests, culture condition should be selected in both cases of the bioburden and sterility testing. Details about choosing criteria are given.

  16. Sterilization, high-level disinfection, and environmental cleaning.

    Science.gov (United States)

    Rutala, William A; Weber, David J

    2011-03-01

    Failure to perform proper disinfection and sterilization of medical devices may lead to introduction of pathogens, resulting in infection. New techniques have been developed for achieving high-level disinfection and adequate environmental cleanliness. This article examines new technologies for sterilization and high-level disinfection of critical and semicritical items, respectively, and because semicritical items carry the greatest risk of infection, the authors discuss reprocessing semicritical items such as endoscopes and automated endoscope reprocessors, endocavitary probes, prostate biopsy probes, tonometers, laryngoscopes, and infrared coagulation devices. In addition, current issues and practices associated with environmental cleaning are reviewed. Copyright © 2011. Published by Elsevier Inc.

  17. "Forgotten" Chapters in the History of Transcervical Sterilization: Carl Clauberg and Hans-Joachim Lindemann.

    Science.gov (United States)

    Hildebrandt, Sabine; Benedict, Susan; Miller, Erin; Gaffney, Michael; Grodin, Michael A

    2017-07-01

    Transcervical sterilization is a non-surgical method of permanent female sterilization that is widely used and critically discussed. A review of the historiography of the method reveals that instances of its coercive use are not included in the historical account. This study offers a reexamination of the work of Carl Clauberg and Hans-Joachim Lindemann, to more deeply contextualize within the framework of current usage the coercive use of transcervical sterilization during the Third Reich and in postwar Germany. This inquiry is based on postwar criminal trial records on Clauberg, and on archival documents detailing Lindemann's activities in 1979. A comparative analysis examines arguments by medical historian Karl-Heinz Roth, and identifies shared characteristics and differences between Clauberg and Lindemann, their methods and scientific connections. The results demonstrate that the technique of transcervical sterilization has an abusive potential that may be explained as a function of the person of the physician, of the scientific method itself, and of societal and political influences. The analysis supports the argument that insights from the cases of Clauberg and Lindemann are transferrable geographically and over time, and have the potential to inform current medical practice, such as transcervical sterilization with the Essure device, whose historiographic exploration remains a desideratum. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus

    International Nuclear Information System (INIS)

    Chen Guochong; Liu Wen; Liu Qingfang

    2011-01-01

    The blood compatibility of the radiation sterilized disposable burette transfusion apparatus was investigated to provide evidence for the safety of radiation sterilized medical devices. The initial bacteria burden of the disposable burette transfusion apparatus was examined according to the ISO11737 standard, and the whole blood clotting time, prothrombin time, partial thromboplastin time and hemolysis rate of the samples were determined. There was no significant difference between the radiation sterilized samples and negative controls on WBCT, PT and PTT (p>0.05). Haemolysis test showed that the haemolysis rate of the sample sterilized by irradiation was 1.38%, which was coincidence with the criteria of the medical devices. After sterilization by irradiation, disposable burette transfusion apparatus show good blood compatibility, which could be considered that radiation sterilization is a biologically safe method for the medical apparatus. (authors)

  19. A randomized, controlled, multicenter contraceptive efficacy clinical trial of the intravas device, a nonocclusive surgical male sterilization

    Directory of Open Access Journals (Sweden)

    Wen-Hong Lu

    2014-06-01

    Full Text Available Because of unavoidable complications of vasectomy, this study was undertaken to assess the efficacy and safety of male sterilization with a nonobstructive intravas device (IVD implanted into the vas lumen by a mini-surgical method compared with no-scalpel vasectomy (NSV. IVDs were categorized into two types: IVD-B has a tail used for fixing to the vas deferens (fixed wing whereas IVD-A does not. A multicenter prospective randomized controlled clinical trial was conducted in China. The study was comprised of 1459 male volunteers seeking vasectomy who were randomly assigned to the IVD-A (n = 487, IVD-B (n = 485 or NSV (n = 487 groups and underwent operation. Follow-up included visits at the 3 rd -6 th and 12 th postoperative months. The assessments of the subjects involved regular physical examinations (including general and andrological examinations and semen analysis. The subjects' partners also underwent monitoring for pregnancy by monthly interviews regarding menstruation and if necessary, urine tests. There were no significant differences in pregnancy rates (0.65% for IVD-A, 0 for IVD-B and 0.21% for NSV among the three groups (P > 0.05. The cumulative rates of complications at the 12 th postoperative month were zero, 0.9% and 1.7% in the three groups, respectively. In conclusion, IVD male sterilization exhibits a low risk of long-term adverse events and was found to be effective as a male sterilization method, similar to the NSV technique. IVD male sterilization is expected to be a novel contraceptive method.

  20. A randomized, controlled, multicenter contraceptive efficacy clinical trial of the intravas device, a nonocclusive surgical male sterilization

    Science.gov (United States)

    Lu, Wen-Hong; Liang, Xiao-Wei; Gu, Yi-Qun; Wu, Wei-Xiong; Bo, Li-Wei; Zheng, Tian-Gui; Chen, Zhen-Wen

    2014-01-01

    Because of unavoidable complications of vasectomy, this study was undertaken to assess the efficacy and safety of male sterilization with a nonobstructive intravas device (IVD) implanted into the vas lumen by a mini-surgical method compared with no-scalpel vasectomy (NSV). IVDs were categorized into two types: IVD-B has a tail used for fixing to the vas deferens (fixed wing) whereas IVD-A does not. A multicenter prospective randomized controlled clinical trial was conducted in China. The study was comprised of 1459 male volunteers seeking vasectomy who were randomly assigned to the IVD-A (n = 487), IVD-B (n = 485) or NSV (n = 487) groups and underwent operation. Follow-up included visits at the 3rd–6th and 12th postoperative months. The assessments of the subjects involved regular physical examinations (including general and andrological examinations) and semen analysis. The subjects’ partners also underwent monitoring for pregnancy by monthly interviews regarding menstruation and if necessary, urine tests. There were no significant differences in pregnancy rates (0.65% for IVD-A, 0 for IVD-B and 0.21% for NSV) among the three groups (P > 0.05). The cumulative rates of complications at the 12th postoperative month were zero, 0.9% and 1.7% in the three groups, respectively. In conclusion, IVD male sterilization exhibits a low risk of long-term adverse events and was found to be effective as a male sterilization method, similar to the NSV technique. IVD male sterilization is expected to be a novel contraceptive method. PMID:24589454

  1. Improved Sterilization of Sensitive Biomaterials with Supercritical Carbon Dioxide at Low Temperature.

    Directory of Open Access Journals (Sweden)

    Anne Bernhardt

    Full Text Available The development of bio-resorbable implant materials is rapidly going on. Sterilization of those materials is inevitable to assure the hygienic requirements for critical medical devices according to the medical device directive (MDD, 93/42/EG. Biopolymer-containing biomaterials are often highly sensitive towards classical sterilization procedures like steam, ethylene oxide treatment or gamma irradiation. Supercritical CO₂ (scCO₂ treatment is a promising strategy for the terminal sterilization of sensitive biomaterials at low temperature. In combination with low amounts of additives scCO₂ treatment effectively inactivates microorganisms including bacterial spores. We established a scCO₂ sterilization procedure under addition of 0.25% water, 0.15% hydrogen peroxide and 0.5% acetic anhydride. The procedure was successfully tested for the inactivation of a wide panel of microorganisms including endospores of different bacterial species, vegetative cells of gram positive and negative bacteria including mycobacteria, fungi including yeast, and bacteriophages. For robust testing of the sterilization effect with regard to later application of implant materials sterilization all microorganisms were embedded in alginate/agarose cylinders that were used as Process Challenge Devices (PCD. These PCD served as surrogate models for bioresorbable 3D scaffolds. Furthermore, the impact of scCO₂ sterilization on mechanical properties of polysaccharide-based hydrogels and collagen-based scaffolds was analyzed. The procedure was shown to be less compromising on mechanical and rheological properties compared to established low-temperature sterilization methods like gamma irradiation and ethylene oxide exposure as well as conventional steam sterilization. Cytocompatibility of alginate gels and scaffolds from mineralized collagen was compared after sterilization with ethylene oxide, gamma irradiation, steam sterilization and scCO₂ treatment. Human

  2. Radiation sterilization of pharmaceuticals (eg chloramphenicol)

    International Nuclear Information System (INIS)

    Zeegers, F.; Tilquin, B.

    1991-01-01

    In connection with the ongoing world-wide application of irradiation as a new technology for sterilization, the identification of the drugs products is very important. Introduction of radiosterilization of pharmaceuticals is proceeding at a slower rate than that for disposable medical supplies; it is the responsibility of the manufacturer to prove that degradation of products is safe. Major advantages in the use of radiation as a sterilization procedure are high penetrating power, small temperature rise, ease of control and minimal degradation of irradiated solid drugs [fr

  3. Human Centred Design Considerations for Connected Health Devices for the Older Adult

    Directory of Open Access Journals (Sweden)

    Richard P. Harte

    2014-06-01

    Full Text Available Connected health devices are generally designed for unsupervised use, by non-healthcare professionals, facilitating independent control of the individuals own healthcare. Older adults are major users of such devices and are a population significantly increasing in size. This group presents challenges due to the wide spectrum of capabilities and attitudes towards technology. The fit between capabilities of the user and demands of the device can be optimised in a process called Human Centred Design. Here we review examples of some connected health devices chosen by random selection, assess older adult known capabilities and attitudes and finally make analytical recommendations for design approaches and design specifications.

  4. A Comparative Study of Ethylene Oxide and Radiation Sterilization of Medical Devices

    International Nuclear Information System (INIS)

    Brewer, J. H.; Keller, G. H.

    1967-01-01

    Both radiation and gas sterilization have been widely accepted for the ''cold'' sterilization of disposable medical supplies. Each of these methods offers certain advantages over the other but has characteristics which make it less satisfactory for specific items. This study is especially concerned with the effectiveness of various dosage levels and gassing cycles on known concentrations of test organisms, as well as similar studies on routine production lots on which presterilization counts were made. The experimental methods employ techniques which were developed for the National Aeronautics and Space Administration Planetary Quarantine Program and are now standard procedures for the sterilization and microbiological examination of space equipment. The results are much more meaningful than were obtained with techniques employed earlier. Good manufacturing practice and plant hygiene are essential for the practical application of both these sterilization methods in order that chosen dosage levels and cycles will ensure a factor of safety. Manufacturing methods to ensure a low microbiological count are described. Data is presented on the effect of composition of materials on retention and survival of contaminants and die-off of contaminants on handled materials and components before sterilization. Factors concerning the cost-effectiveness of the two methods and other engineering values are discussed. (author)

  5. [Importance of material logistics in the interface management of operation departments: is the supply of sterile equipment a new business area of operation room organization?].

    Science.gov (United States)

    Schmeck, J; Schmeck, S B; Kohnen, W; Werner, C; Schäfer, M; Gervais, H

    2008-08-01

    The implementation of diagnosis-related groups (DRGs) sharply increased economic pressure on hospitals. Hence, process optimization was focussed on cost-intensive areas, namely the operation room (OR) departments. Work-flow in the OR is characterized by a mandatory interlocking of the job functions of many different occupational groups and the availability of a variety of different materials. Alternatives for staff assignment optimization have been published in numerous publications dealing with the importance of OR management. In this connection the issue of material logistics in the context of OR management has not been frequently addressed. In order to perform a surgical procedure according to plan, one depends on personnel and on timely availability of the materials needed. Supply of sterilized materials is of utmost importance, because in most hospitals sterilized surgical devices constitute a critical resource. In order to coordinate the OR process with the production flow of sterilized materials, an organizational connection to the OR management makes sense. Hence, in a German university hospital the Department of Hospital Sterile Supplies was integrated into the OR management of the Department of Anesthesiology. This led to a close coordination of work-flow processes, and concomitantly a significant reduction of production costs of sterile supplies could be achieved by direct interaction with the OR. Thus, hospital sterile supplies can reasonably be integrated into an OR management representing a new interesting business area for OR organization.

  6. Small bowel obstruction and perforation after Essure sterilization: a case report.

    Science.gov (United States)

    Mantel, Hendrik T J; Wijma, Jacobus; Stael, Adrianus P M

    2013-01-01

    We present a rare but serious complication of Essure microinsert sterilization. Case report. A 42-year-old woman presented with nausea, vomiting, abdominal pain and abdominal distension 1 month after uncomplicated Essure sterilization. Abdominal X-ray showed small bowel obstruction. At subsequent laparotomy, a stretched Essure device was found ensnaring the terminal ileum. It had caused strangulation and local perforation of the bowel wall. The device was removed and an ileocecal resection with side-to-side ileocolostomy was performed. In retrospect, the aberrant location of the right Essure device near the ileocecal junction was noticed on the abdominal X-ray. This case illustrates that perforation of an Essure device can result in a serious complication leading to ileocecal resection. An abdominal X-ray with specific attention to the correct location of the Essure coils is advisable for patients presenting with small bowel obstruction after Essure sterilization. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. A Secure and Robust Connectivity Architecture for Smart Devices and Applications

    Directory of Open Access Journals (Sweden)

    Lee YangSun

    2011-01-01

    Full Text Available Convergence environments and technologies are urgently coming close to our life with various wireless communications and smart devices in order to provide many benefits such as connectivity, usability, mobility, portability, and flexibility as well as lower installation and maintenance costs. Convergence has brought important change not only in the way we live but also in the way we think. It is the progress towards the attempt to create and to evolve new valuable services through the device convergence and fusion of in-home, office, and various environments around the personal mobile apparatus. Based on the dynamic trends of convergence, it is widely argued that the increased requirements on secure and robust connectivity between a variety of mobile devices and their applications provide us the era of real pervasive computing environment. Thus, in this paper, we present a novel connectivity architecture using RF4CE-(Radio Frequency for Consumer Electronics- based wireless zero-configuration and enhanced key agreement approach. We analyze the security and performance of our proposed approach by the development of the prototype H/W and the construction of a testbed with CE and mobile devices.

  8. Converting from EtO to radiation sterilization: educating the medical supply industry

    Energy Technology Data Exchange (ETDEWEB)

    Bedward, D.A.; Brinston, R.M.; Kotler, J. [Nordion International Inc., Ontario (Canada)

    1995-10-01

    This paper examines some relevant factors influencing the conversion from ethylene oxide sterilization to gamma sterilization. Marketing tactics to promote and stimulate this activity are reviewed. TEAM GAMMA, an educational vehicle developed by Norion International Inc., is described from the concept acceptance to the very positive results obtained. The structure of this multi disciplinary team of consultants is described. Topics presented by this team include sterilization basics, material compatability, device design manufacturing and other aspects of the sterilization process. It is concluded that assisting in the education of the medical device manufacturers regarding the conversion from EtO to gamma processing provides payback for Nordion and the gamma processing industry. This assessment is based on the results of the ten seminars presented to date. (author).

  9. Converting from EtO to radiation sterilization: educating the medical supply industry

    International Nuclear Information System (INIS)

    Bedward, D.A.; Brinston, R.M.; Kotler, J.

    1995-01-01

    This paper examines some relevant factors influencing the conversion from ethylene oxide sterilization to gamma sterilization. Marketing tactics to promote and stimulate this activity are reviewed. TEAM GAMMA, an educational vehicle developed by Norion International Inc., is described from the concept acceptance to the very positive results obtained. The structure of this multi disciplinary team of consultants is described. Topics presented by this team include sterilization basics, material compatability, device design manufacturing and other aspects of the sterilization process. It is concluded that assisting in the education of the medical device manufacturers regarding the conversion from EtO to gamma processing provides payback for Nordion and the gamma processing industry. This assessment is based on the results of the ten seminars presented to date. (author)

  10. The processing technology of bread crumbs sterilization by irradiation

    International Nuclear Information System (INIS)

    Zhu Jiating; Li Zhengkui; Zhao Yongfu; Zhang Weidong; Jin Jie; Wu Lei; Wang Xinghai

    2003-01-01

    The processing technology of bread crumbs sterilization by irradiation was studied. The results demonstrated that dose heterogeneity had osculatory connection with pile height and turning, sterilization effect had positive correlation with the irradiation dose and negative correlation with colour. Compared with the CK, the content of crud protein, fat, carbohydrate, microelement and amino acid in irradiated bread crumbs had no obvious change. It is recommended that the range of best sterilization dose be 6-10 kGy and the shelf time of bread crumbs be extended to one year

  11. Struggling to Hear? Tiny Devices Can Keep You Connected

    Science.gov (United States)

    ... Human Services Search form Search Site Menu Home Latest Issue Past Issues Special Issues Subscribe May 2018 Print this issue Struggling to Hear? Tiny Devices Can Keep You Connected En español Send us ...

  12. A Collaborative Evaluation Framework for Biometric Connected Devices in Healthcare.

    Science.gov (United States)

    Farnia, Troskah; Jaulent, Marie Christine; Marchand, Guillaume; Yasini, Mobin

    2017-01-01

    A large number of biometric connected devices are currently available with a variety of designs. Healthcare users cannot easily choose the reliable ones that correspond the best to their healthcare problems. The existing evaluation methods do not consider at the same time aspects of connectivity and healthcare usage. In this study, a collaborative evaluation framework for biometric connected devices in healthcare usage is proposed. This framework contains six dimensions: medical validity, technical reliability, usability, ergonomy, legal compliance, and accuracy of measurements. In a first step, these dimensions were assessed by designing a self administered questionnaire answered by the stakeholders (patients, health professionals, payers, and manufacturers). A case study was then carried out in a second step to test this framework in a project of telemonitoring for heart failure patients. The results are in favor of the efficiency of the proposed framework as a decision making tool in healthcare usage.

  13. Dose setting for radiation sterilization of disposable medical device, (3)

    International Nuclear Information System (INIS)

    Iwasaki, Yoshio; Hosobuchi, Kazunari.

    1985-01-01

    The microbial burden and dose setting for radiation sterilization of tampon for menstrual hygiene were examined, and the following results were obtained. 1. The maximum and minimum contaminants per a tampon were 100 and 0, and the average was 46.1. 2. The 91.2 % of the 125 strains isolated from the tampon was identified as bacilli by the microbiological and biochemical activities, and Bacillus pumilus compried 35.2 % of the strains. B. pumilus and B. megaterium spores indicated the highest radioresistance among those contaminants and both D-values were 0.22 Mrad. 3. The difference in the D-value was not found for the radioresistance of standard strain carried on a tampon and a glass fiber filter. 4. The sterilization dose (SD) was calculated to be 1.10 Mrad by the formula SD = D x log (No/N), while the SD was 0.90 and 0.76 Mrad, respectively, for the microbial burden informations and steility tests. From above ressults, it is supposed that the sterility assurance level in 10 -3 can be achieved by irradiating the dose less than 1 Mrad. (author)

  14. Dosimetry intercomparisons in European medical device sterilization plants

    DEFF Research Database (Denmark)

    Miller, A.; Sharpe, P.H.G.

    2000-01-01

    Dosimetry intercomparisons have been carried out involving two-thirds of all European radiation sterilization facilities. Dosimeters for the intercomparisons were supplied by two accredited calibration laboratories. The results show good agreement, and indicate overall dosimetry accuracy of the o...... of the order of +/-5% (1 sigma) for both Co-60 and electron beam plants. (C) 2000 Elsevier Science Ltd. All rights reserved....

  15. Sterilization of instruments in solar ovens

    Energy Technology Data Exchange (ETDEWEB)

    Fjendbo Joergensen, A. [Odense Univ. Hospital, Dept. of Infectious Diseases, Odense (Denmark); Noehr, K. [Odense Technical College, Dept. of Metal, Odense (Denmark); Boisen, F. [The Danish Veterinary and Food Administration Funen, Dept. of Microbiology, Odense (Denmark)

    2000-07-01

    The sterilization of instruments in rural health clinics in less developed countries is an increasing problem because chemical methods can no longer be recommended and wood fuel is becoming more and more scarce. Thus, it seemed obvious to try to utilize solar energy for sterilization purposes. A solar oven was designed and manufactured using local materials and simple tools. The solar oven was tested by physical, chemical, and microbiological methods. A mathematical model for the sterilization effect was developed and programmed into a microprocessor that was connected to a thermocouple. The microprocessor switches on a green light when the sterilization is completed. After successful testing, the oven was built into the west-facing wall of a rural health clinic and used daily for sterilization. The oven was able to generate temperatures above 180 deg. C. On all days with direct sunlight the oven fulfilled the international recommendations for hot air sterilization because no growth could be detected from any of the test bacteria spores. The chemical indicators Brownes tubes types 3 and 5 also changed colours. The solar oven was easy to use for the clinic staff, but during the seasons with low sun position (in Tanzania, December and June) it was difficult to achieve a high enough temperature for sterilization. Therefore, if the method is to be used throughout the year the oven must be moved to collect the sun's rays from several directions, or the clinic must have more than one solar oven facing in different directions. We conclude that the solar oven is a realistic method for sterilization of instruments. (au)

  16. Bacterial spores survive treatment with commercial sterilants and disinfectants.

    Science.gov (United States)

    Sagripanti, J L; Bonifacino, A

    1999-09-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data obtained with a sensitive and quantitative test suggest that commercial liquid sterilants and disinfectants are less effective on contaminated surfaces than generally acknowledged.

  17. Measurement campaign on connectivity of mesh networks formed by mobile devices

    DEFF Research Database (Denmark)

    Pietrarca, Beatrice; Sasso, Giovanni; Perrucci, Gian Paolo

    2007-01-01

    This paper reports the results of a measurement campaign on the connectivity level of mobile devices using Bluetooth (BT) to form cooperative mobile mesh networks. Such mobile mesh networks composed of mobile devices are the basis for any peer-to-peer communication like wireless grids or social...

  18. International standard (ISO) of radiation sterilization and issues in the sterilization dose setting

    International Nuclear Information System (INIS)

    Takehisa, Masaaki

    1995-01-01

    The ISO dose setting method 1 uses bioburden and verification by sublethal sterility test. Current devices produced in clean environmental have low bioburden, however, sensitivity of verification test declines at low bioburden. Validation of verification in this region should be further studied. A dose setting using D 10 of bioburden isolates should be reevaluated and included in the ISO. (author)

  19. Excellent nonlinearity of a selection device based on anti-series connected Zener diodes for ultrahigh-density bipolar RRAM arrays

    International Nuclear Information System (INIS)

    Li, Yingtao; Li, Rongrong; Wang, Yang; Tao, Chunlan; Fu, Liping; Gao, Xiaoping

    2015-01-01

    A crossbar array is usually used for the high-density application of a resistive random access memory (RRAM) device. However, the cross-talk interference limits the increase in the integration density. In this paper, anti-series connected Zener diodes as a selection device are proposed for bipolar RRAM arrays. Simulation results show that, by using the anti-series connected Zener diodes as a selection device, the readout margin is sufficiently improved compared to that obtained without a selection device or with anti-parallel connected diodes as the selection device. The maximum size of the crossbar arrays with anti-series connected Zener diodes as a selection device over 1 TB is estimated by theoretical simulation. In addition, the feasibility of using the anti-series connected Zener diodes as a selection device for bipolar RRAM is demonstrated experimentally. These results indicate that anti-series connected Zener diodes as a selection device opens up great opportunities to realize ultrahigh-density bipolar RRAM arrays. (paper)

  20. Searching for a strategy to gamma-sterilize Portuguese cork stoppers - preliminary studies on bioburden, radioresistance and sterility assurance level

    International Nuclear Information System (INIS)

    Botelho, M.L.; Almeida-Vara, E.; Andrade, M.E.; Tenreiro, R.

    1988-01-01

    A gamma radiation plant will start running next year in Portugal, to sterilize medical devices and wine cork stoppers. As Portugal is the first world producer, manufacturer and exporter of wine cork stoppers, an efficient sterilizing procedure is required to overcome moulding from long term shipping. Preliminary research on cork stoppers bioburden and microflora radioresistance allowed to establish reliable D 10 and Sterility Assurance Level (SAL) values. Studied samples showed an initial average contamination of about 10 4 c.f.u. per cork stopper. The determined D 10 values for fungi were not higher than 2 kGy. In these conditions, a SAL of 10 -4 can be expected when the product is treated at a minimum absorbed dose of 15 kGy. (author)

  1. Sterilization of health care products - Radiation. Part 2: Establishing the sterilization dose

    International Nuclear Information System (INIS)

    2006-01-01

    devised specifically for substantiation of 25 kGy, Method VD max, was put forward by Kowalski and Tallentire (1999) [14]. Subsequent evaluations involving computational techniques demonstrated that the underlying principles were soundly based (Kowalski, Aoshuang and Tallentire, 2000) [13] and field trials confirmed that Method VD max is effective in substantiating 25 kGy for a wide variety of medical devices manufactured and assembled in different ways (Kowalski et al., 2002) [16]. A standardized procedure for the use of VD max for substantiation of a sterilization dose of 25 kGy has been published in the AAMI Technical Information Report Sterilization of health care products -- Radiation sterilization -- Substantiation of 25 kGy as a sterilization dose - Method VD max (AAMI TIR27:2001) [5], a text on which the method described herein is largely based. Method VD max is founded on dose setting Method 1 and, as such, it possesses the high level of conservativeness characteristic of Method 1. In a similar manner to the dose setting methods, it involves performance of tests of sterility on product items that have received a dose of radiation lower than the sterilization dose. The outcomes of these tests are used to substantiate that 25 kGy achieves an SAL of 10 -6 . To link the use of VD max for the substantiation of a particular preselected sterilization dose, the numerical value of the latter, expressed in kGy, is included as a superscript to the VD max symbol. Thus, for substantiation of a sterilization dose of 25 kGy the method is designated VD max 25 . Method VD max 15 is based on the same principles as Method VD max 25 described above. The test procedure is the same as Method VD max 25 , but VD max 15 is limited to product with average bioburden ≤ 1,5. The outcomes of these tests are used to substantiate that 15 kGy achieves a sterility assurance level of 10 -6 . This part of ISO 11137 also describes methods that may be used to carry out sterilization dose audits in

  2. In vitro study on the disinfectability of two split-septum needle-free connection devices using different disinfection procedures

    Directory of Open Access Journals (Sweden)

    Engelhart, Steffen

    2015-12-01

    Full Text Available This in vitro study investigated the external disinfection of two needle-free connection devices (NFC using Octeniderm (spraying and wiping technique vs. Descoderm pads (wiping technique. The split-septum membrane of the NFC was contaminated with >10 CFU . The efficacy of the disinfection at 30 sec. exposure time was controlled by taking a swab sample and by flushing the NFC with sterile 0.9% sodium chloride solution. Disinfection with octenidine dihydrochloride 0.1 g, 1-Propanol 30.0 g, and 2-Propanol 45.0 g in solution was highly effective (CFU reduction ≥4 log against both microorganisms, whereas the use of 63.1 g 2-Propanol in 100 ml solution led to residual contamination with . Our investigation underlines that (i in clinical practice disinfection of NFCs before use is mandatory, and that (ii details of disinfection technique are of utmost importance regarding their efficacy. Our investigation revealed no significant differences between both split-septum NFC types. Clinical studies are needed to confirm a possible superiority of disinfectants with long-lasting residual antimicrobial activity.

  3. Postpartum Sterilization

    Science.gov (United States)

    f AQ FREQUENTLY ASKED QUESTIONS FAQ052 CONTRACEPTION Postpartum Sterilization • What is sterilization? • What is postpartum sterilization? • How is postpartum sterilization performed? • What kind of anesthesia is used for postpartum sterilization? • How ...

  4. Proposed Philippine radiation-sterilization plant, and a survey of market potential

    International Nuclear Information System (INIS)

    Singson, C.C.; Ibe, L.D.

    1975-01-01

    The paper deals with a study to assess the market potential of radiation sterilization in the Philippines. A market survey conducted with the technical assistance of an IAEA expert from India shows that most of the pharmaceutical industries engaged in the manufacture of medical products unanimously agree that there is an urgent need for a centralized radiation sterilization plant to meet the demands of sterilization of most of their products and packaging materials. The authorities of the government and some of the private hospitals surveyed are also very keen for the establishment of a sterilization facility since most modern medical products and devices are made of heat-sensitive thermoplastics which cannot be heat or steam sterilized. Availability of sterile products will help improve the public health standards of the population. The scope of the utilization of a radiation-sterilization facility in Diliman Quezon City is also discussed. (author)

  5. Bacterial Spores Survive Treatment with Commercial Sterilants and Disinfectants

    OpenAIRE

    Sagripanti, Jose-Luis; Bonifacino, Aylin

    1999-01-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data ob...

  6. Hysteroscopic Sterilization

    Science.gov (United States)

    ... sterilization? Sterilization is a permanent form of birth control. What is tubal sterilization? Sterilization procedures for women are ... is quicker than from other types of sterilization. What are the risks of ... on for birth control. • There is a risk of injury to the ...

  7. Sterilization by oxygen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Adir Jose; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Silva Zambon, Luis da; Silva, Monica Valero da; Verdonck, Patrick Bernard

    2004-07-31

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  8. [Essure--a novel method of sterilization].

    Science.gov (United States)

    Revel, Ariel; Nadjary, Michel; Shushan, Asher

    2008-02-01

    Essure hysteroscopic sterilization is a minimally invasive, outpatient approach to female sterilization, which avoids the possible complications of laparoscopic sterilization. This procedure has been available since 2003 in both Europe and North America. We present our experience of the first 12 cases of the procedure performed in Israel. Women who have completed their family planning were offered to consider Essure as their permanent contraception. The procedure was performed without anesthesia by the vaginoscopic technique at the hospital's outpatient clinic. Patients completed a questionnaire and were discharged immediately following the procedure. A follow-up checkup was completed after three months including three dimensional sonography, abdominal X-ray and occasional hysterosalpingogram. Twelve patients participated in the pilot group at Hadassah. The average age was 40 years (34-45) and the average number of children was 5 (4-8). The average time for the procedure was under 8 minutes. Periostial adhesions required adhesiolysis prior to insertion of the device in one patient. All patients resumed their normal activity on the same day. Our patient satisfaction survey revealed that the procedure was associated with high satisfaction levels. Sonographic and radiographic studies confirmed the good placement of the device. The Essure procedure was well tolerated by patients. The limitation is probably going to be the price of Essure, as this procedure is not covered by the 'health basket' in Israel.

  9. Using Mobile Devices to Connect Teachers and Museum Educators

    Science.gov (United States)

    Delen, Ibrahim; Krajcik, Joseph

    2017-01-01

    The use of mobile devices is increasing rapidly as a potential tool for science teaching. In this study, five educators (three middle school teachers and two museum educators) used a mobile application that supported the development of a driving question. Previous studies have noted that teachers make little effort to connect learning experiences…

  10. Connecting device for external ends of steam generator anti-vibration bars

    International Nuclear Information System (INIS)

    Boula, G.; Roinjard, J.P.

    1990-01-01

    The connexion device comprises a support that is fixed over the external end of an antivibration bar with a tap aperture and a connexion arm fixed to it on one extremity and one the other end to a sleeve with a connecting screw. The connecting screw engages through the bore of the sleeve into an opening in the adjacent support fixed over a second antivibration bar [fr

  11. Development and testing of a new disposable sterile device for labelling white blood cells

    NARCIS (Netherlands)

    Signore, A.; Glaudemans, A. W. J. M.; Malviya, G.; Lazzeri, E.; Prandini, N.; Viglietti, A. L.; De Vries, E. F. J.; Dierckx, R. A. J. O.

    Aim. White blood cell (WBC) labelling requires isolation of cells from patient's blood under sterile conditions using sterile materials, buffers and disposables under good manufacturing practice (GMP) conditions. Till now, this limited the use of white blood cell scintigraphy (WBC-S) only to well

  12. Investigation of radiation gamma-sterilization effect on sodium alginate hydrogels

    International Nuclear Information System (INIS)

    Valueva, M.I.; Oltarzhevskaya, N.D.; Maksimova, Yu.S.; Fenin, A.A.

    2012-01-01

    The effect of gamma-radiation in doses ensuring materials sterility (6-15 kGy) on alginate hydrogels is studied. For conservation of polymer solutions viscosity after sterilization it is necessary to introduce in polymer matrix different additives inhibiting the radiolysis process. Substances-antioxidants (aqueous extracts of sea-buckthorn and blueberry), polyvinylpyrrolidone, pectin, polyethylene oxides with molecular mass from 400 to 40000 have been studied as the additives. The additives selected have the positive effect on the result of alginate hydrogels sterilization. It is established, that the problem of human tissue radiation protection is closely connected with the problem of biopolymer hydrogels radiation protection [ru

  13. The impact of European standards concerning radiation sterilization on the quality assurance of medical products in Poland

    International Nuclear Information System (INIS)

    Kaluska, I.; Zimek, Z.

    1999-01-01

    The ISO 11137 and EN 552 standards were issued in the mid-90's. These documents have been devoted to the requirements regarding the sterile medical devices offered on the market. The implementation of those standards by Polish manufacturers of medical devices is discussed in this paper. The currently introduced national regulations effectively stimulated this process. The activities of the Institute of Nuclear Chemistry and Technology (INCT) in the field of radiation sterilization standardization and its radiation sterilization commercial service are described. (author)

  14. Analysis of a carcinogen, 4,4'-methylenedianiline, from thermosetting polyurethane during sterilization.

    Science.gov (United States)

    Shintani, H; Nakamura, A

    1989-01-01

    Polyurethane (PU) is widely used in medical devices such as potting material in artificial dialysis devices, plasma separators, etc. Gamma-ray irradiation is frequently used for the sterilization of such devices. This paper reports that a carcinogen, 4,4'-methylenedianiline (MDA, p,p'-diaminodiphenylmethane), is produced from medical thermosetting PU by gamma-ray irradiation. Gamma-ray irradiated PU was immersed in methanol or equine serum. The serum was treated with a mixture of 5N HCIO4:acetonitrile (1:10) in order to deproteinate and recover MDA. It was found that MDA is formed from thermosetting PU at around a few ppm in the original sample. The production of MDA increased with increasing irradiation dose. The MDA amount formed was related to the irradiation dose by a second order equation. Results of methanol and serum extraction were similar. Pressurized steam (autoclave) sterilization in place of gamma-ray sterilization was also examined. MDA production was not found in autoclave sterilization procedures. Gel permeation chromatography (GPC) of methanol or N,N-dimethylformamide (DMF) extract of irradiated PU showed that the PU oligomers eluted. Time course of methanol extract of irradiated PU was detected at 245.5 nm. This showed an exponential decline regardless of doses of irradiation.

  15. Analysis of a carcinogen, 4,4'-methylenedianiline, from thermosetting polyurethane during sterilization

    International Nuclear Information System (INIS)

    Shintani, H.; Nakamura, A.

    1989-01-01

    Polyurethane (PU) is widely used in medical devices such as potting material in artificial dialysis devices, plasma separators, etc. Gamma-ray irradiation is frequently used for the sterilization of such devices. This paper reports that a carcinogen, 4,4'-methylenedianiline (MDA, p,p'-diaminodiphenylmethane), is produced from medical thermosetting PU by gamma-ray irradiation. Gamma-ray irradiated PU was immersed in methanol or equine serum. The serum was treated with a mixture of 5N HCIO4:acetonitrile (1:10) in order to deproteinate and recover MDA. It was found that MDA is formed from thermosetting PU at around a few ppm in the original sample. The production of MDA increased with increasing irradiation dose. The MDA amount formed was related to the irradiation dose by a second order equation. Results of methanol and serum extraction were similar. Pressurized steam (autoclave) sterilization in place of gamma-ray sterilization was also examined. MDA production was not found in autoclave sterilization procedures. Gel permeation chromatography (GPC) of methanol or N,N-dimethylformamide (DMF) extract of irradiated PU showed that the PU oligomers eluted. Time course of methanol extract of irradiated PU was detected at 245.5 nm. This showed an exponential decline regardless of doses of irradiation

  16. Trends in sterilization since the introduction of Essure hysteroscopic sterilization.

    Science.gov (United States)

    Shavell, Valerie I; Abdallah, Mazen E; Shade, George H; Diamond, Michael P; Berman, Jay M

    2009-01-01

    To investigate trends in sterilization in women at the Detroit Medical Center, Michigan (DMC), since the introduction of Essure hysteroscopic sterilization. Retrospective study (Canadian Task Force classification II-2). Outpatient surgery center and university teaching hospitals. Women who underwent interval sterilization procedures at the DMC (Hutzel Women's Hospital, Sinai-Grace Hospital, and the Berry Center) and postpartum sterilization procedures at Hutzel Women's Hospital between January 1, 2002, and December 31, 2007. Permanent sterilization procedures including minilaparotomy tubal ligation, laparoscopic sterilization, Essure hysteroscopic sterilization, and postpartum tubal ligation performed at the time of cesarean section or after vaginal delivery. In all, 5509 permanent sterilization procedures were performed in the 6 years between January 1, 2002, and December 31, 2007, at the DMC facilities analyzed: 2484 interval sterilization procedures at Hutzel Women's Hospital, Sinai-Grace Hospital, and the Berry Center, and 3025 postpartum tubal ligations at Hutzel Women's Hospital. From 2002 through 2007, the decrease in laparoscopic sterilizations from 97.9% to 48.5% of all interval sterilization procedures corresponded significantly with the increase in Essure hysteroscopic sterilizations from 0.0% to 51.3% (p Essure hysteroscopic sterilizations increased significantly from 0.0% to 51.3% of all procedures. Since the approval of Essure hysteroscopic sterilization in November 2002, this minimally invasive method of hysteroscopic sterilization has increased in popularity at the DMC.

  17. Control and Constraint for Low-Income Women Choosing Outpatient Sterilization

    Science.gov (United States)

    Leyser-Whalen, Ophra; Berenson, Abbey B.

    2012-01-01

    Little is known about Hispanics and their contraceptive choices in general, with some past studies detailing non-consensual sterilization. This article is based on interviews with a mostly Hispanic sample of 44 women being sterilized at a public clinic in southeast Texas with the Essure device, which entails a new outpatient sterilization procedure. These women cited relationship factors, wanting to better their and their children’s lives, and past reproductive histories as reasons for deciding on sterilization. They specifically chose Essure as a result of an apprehension of surgery and potential side effects from tubal ligation. Their choices, however, were limited by larger structural factors of work, family, the political economy, and the health care system. We conclude that this new sterilization technique provided more contraceptive choices for these women, yet more contraceptive decision making autonomy, as well as more equitable social structures, are still needed. PMID:23761929

  18. The Development of 1Balance: A Connected Medical Device for Measuring Human Balance

    Directory of Open Access Journals (Sweden)

    Heikki Sjöman

    2018-05-01

    Full Text Available Prototyping (iterative loops of design–build–test is a proven method of efficiently developing new products. Developing products not only quickly, but that are also fit for purpose, implies engaging the end users and iterating the technology at hand. However, there is currently little research on how engineering design can approach developing connected devices. The purpose of this paper is to distinguish and discuss design approaches that are suitable for connected devices. Internet of Things devices consist of both the physical products themselves and the data that is coming out of the products, which we define as the external and internal data, respectively. They both can be prototyped separately, but since the data acquired can influence the design of the device and vice versa, we propose to link these two together in the product development process. This issue becomes more apparent when designing networks of sensors, e.g., for complex artificial intelligence (AI databases. We explain the principle by describing the development of 1Balance through six different prototypes for human balance measurement. Technologically quantifying balance is an underused approach for objectively evaluating the state of a human’s performance. The authors have developed a mobile application for monitoring balance as a physiological signal (amount of sway via a compact wireless inertial measurement unit (IMU sensor strapped to the body of the subject for the duration of the measurement. We describe the design process for developing this connected medical device, as well as how the acquired data was used to improve the design of the product. In conclusion, we propose conceptually connecting the external and internal data prototyping loops.

  19. Utilization of ionizing radiation for the sterilization of membraneous connective tissue allografts. Part of a coordinated programme on radiation sterilization of medical products and biological tissues

    International Nuclear Information System (INIS)

    Triantafyllou, N.

    1978-05-01

    The work carried out, covered several aspects of radiation sterilization of membraneous allografts. In general the findings show that the sterilization of biological membranes with gamma irradiation using doses of up to 3 Mrads is a very satisfactory method for the sterilization of the material, since it does not seriously alter the biological properties of allografts. As for the changes of the mechanical properties, this is not considered to be a serious draw back, because the membraneous allografts cover surgical needs where the mechanical strength is not of paramount importance

  20. Cleaning, disinfection and sterilization of surface prion contamination.

    Science.gov (United States)

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. Analysis and protective measures of sharp instrument injury causes of sterilization and supply center

    Directory of Open Access Journals (Sweden)

    Hua YANG

    2014-11-01

    Full Text Available Objective: To analyze the causes of sharp injury in the sterilization and supply center, take protective measures, effectively avoid sharp instrument injury, and guarantee staff safety. Methods: Adopt a retrospective survey method, summarize sharp instrument injury data of sterilization and supply center in 2013, analyze the reasons of the occurrence of sharp instrument injury, and make protective countermeasures. Results: Sharp instrument injuries occurred mainly in the device classification, manual cleaning and device packaging process. Conclusion: Poor consciousness of occupational protection of the staff in the sterilization and supply center, nonstandard operation, and lack of training and supervision in place are the main reasons of occurrence of sharp instrument injury.

  2. Radiation sterilization and volatile matter used for medical devices touching to blood

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Akitada; Sato, Michio; Igarashi, Yoshiaki; Yagami, Takeshi [National Inst. of Health Sciences, Tokyo (Japan); Yoshii, Fumio

    1998-02-01

    In this study, it was conducted by using chemical analysis and cell toxic test if any volatile matter actually on radiation, if any matter could be detected when its generating, if it stayed to a safe volume range, and so forth. Objective materials of this study focus the elements used for medical devices always touching blood having large effect on human bodies. In this fiscal year, because of many cases of sterilization after filling water and necessary gas-liquid equilibrium for quantitative method using a head space when actually using the materials for dialyzer, irradiation was conducted after filling water into the material, comparison of gas volume and evaluation of safety with those of conventional experiments. As a result, by {gamma}-ray irradiation, various matters are formed, and some volatile matters less than some ng level in present volume could be detected. However, from a standpoint of safety data and forming volume of the cell toxic test results, there were no matter anxious to safety. Furthermore, the present dialyzer and others are washed before using chemically, and its safety seems to be fully held. (G.K.)

  3. Radiation sterilization and volatile matter used for medical devices touching to blood

    International Nuclear Information System (INIS)

    Nakamura, Akitada; Sato, Michio; Igarashi, Yoshiaki; Yagami, Takeshi; Yoshii, Fumio

    1998-01-01

    In this study, it was conducted by using chemical analysis and cell toxic test if any volatile matter actually on radiation, if any matter could be detected when its generating, if it stayed to a safe volume range, and so forth. Objective materials of this study focus the elements used for medical devices always touching blood having large effect on human bodies. In this fiscal year, because of many cases of sterilization after filling water and necessary gas-liquid equilibrium for quantitative method using a head space when actually using the materials for dialyzer, irradiation was conducted after filling water into the material, comparison of gas volume and evaluation of safety with those of conventional experiments. As a result, by γ-ray irradiation, various matters are formed, and some volatile matters less than some ng level in present volume could be detected. However, from a standpoint of safety data and forming volume of the cell toxic test results, there were no matter anxious to safety. Furthermore, the present dialyzer and others are washed before using chemically, and its safety seems to be fully held. (G.K.)

  4. Sensitivity of viruses to radiation sterilization

    International Nuclear Information System (INIS)

    Dziedzic Goclawska; A

    1999-01-01

    kGy, the reduction of 9 (6+3) log 10 units, or a dose of 36 kGy, would be required, and if D 10 is 5.6 kGy, than a dose >50 kGy would be needed to inactivate HIV (Conway and Tomford , CID 14: 978, 1992). These results are in agreement with data published by Fideler et al. (J Bone Jnt Surg.76A: 1032, 1994) who found that doses of 30-40 kGy are required to inactivate HIV in fresh frozen bone allografts. The doses cited above exceed the dose of 25 kGy currently recommended and commonly used by many tissue banks in the world with the exception of the Central Tissue Bank in Warsaw, where the dose of 33 kGy + 10% has been routinely used since 1963. Taking into consideration the results cited above it seems advisable to increase the sterilizing dose for tissue allografts at least up to 35 kGy. It should be kept in mind, however, that high doses of ionizing radiation can evoke numerous chemical and physical changes which may affect the quality of tissue allografts, such as the mechanical properties of bone or other connective tissue grafts or the osteoinductive capacity of bone allografts as well as their resorption rate. It has been observed, however, that radiation-induced changes in quality of tissue allografts depend on two groups of factors: i) conditions of irradiation (dose, temperature) and ii) the method of preservation (deep-freezing, lyophilization). These factors may dramatically influence the radiation damage of collagen a major constituent of connective tissue allografts. Further studies are needed on the effect of radiation sterilization conditions and preservation procedures on degradation of connective tissue allograft constituents

  5. Essure Microinsert Abdominal Migration after Hysteroscopic Tubal Sterilization of an Appropriately Placed Essure Device: Dual Case Reports and Review of the Literature.

    Science.gov (United States)

    Rezai, Shadi; LaBine, Meghan; Gomez Roberts, Hunter Azdel; Lora Alcantara, Isamarie; Henderson, Cassandra E; Elmadjian, Malvina; Nuritdinova, Dilfuza

    2015-01-01

    Background. The Essure device is a method of permanent sterilization widely used in the US that has proven to be safe and effective in most cases. However, there have been reports of device migration that have led to failed tubal occlusion as well as several other serious complications resulting from the presence of the device in the abdominal cavity. Case. This paper represents two cases of failed tubal occlusion by an appropriately placed Essure device without signs or symptoms of further complications related to device migration. Conclusion. Although there have only been 13 reported cases of abdominal device migration since November 2014, this case indicates that the actual number may be higher than reported since it is possible for migration to occur without additional complications. In the majority of reported cases of abdominal migration a major complication requiring surgical correction occurred, such as adhesions, small bowel obstruction, bowel perforation, or persistent pelvic pain. To avoid these complications it is recommended that migrating implants be removed; however, this case also represents an example of when a migrating device may remain in situ in an asymptomatic patient.

  6. Essure Microinsert Abdominal Migration after Hysteroscopic Tubal Sterilization of an Appropriately Placed Essure Device: Dual Case Reports and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Shadi Rezai

    2015-01-01

    Full Text Available Background. The Essure device is a method of permanent sterilization widely used in the US that has proven to be safe and effective in most cases. However, there have been reports of device migration that have led to failed tubal occlusion as well as several other serious complications resulting from the presence of the device in the abdominal cavity. Case. This paper represents two cases of failed tubal occlusion by an appropriately placed Essure device without signs or symptoms of further complications related to device migration. Conclusion. Although there have only been 13 reported cases of abdominal device migration since November 2014, this case indicates that the actual number may be higher than reported since it is possible for migration to occur without additional complications. In the majority of reported cases of abdominal migration a major complication requiring surgical correction occurred, such as adhesions, small bowel obstruction, bowel perforation, or persistent pelvic pain. To avoid these complications it is recommended that migrating implants be removed; however, this case also represents an example of when a migrating device may remain in situ in an asymptomatic patient.

  7. The sterile-male-release technique in Great Lakes sea lamprey management

    Science.gov (United States)

    Twohey, Michael B.; Heinrich, John W.; Seelye, James G.; Fredricks, Kim T.; Bergstedt, Roger A.; Kaye, Cheryl A.; Scholefield, Ron J.; McDonald, Rodney B.; Christie, Gavin C.

    2003-01-01

    The implementation of a sterile-male-release technique from 1991 through 1999 and evaluation of its effectiveness in the Great Lakes sea lamprey (Petromyzon marinus) management program is reviewed. Male sea lampreys were injected with the chemosterilant bisazir (P,P-bis(1-aziridinyl)-N-methylphosphinothioic amide) using a robotic device. Quality assurance testing indicated the device delivered a consistent and effective dose of bisazir. Viability of embryos in an untreated control group was 64% compared to 1% in a treatment group. A task force developed nine hypotheses to guide implementation and evaluation of the technique. An annual average of 26,000 male sea lampreys was harvested from as many as 17 Great Lakes tributaries for use in the technique. An annual average of 16,100 sterilized males was released into 33 tributaries of Lake Superior to achieve a theoretical 59% reduction in larval production during 1991 to 1996. The average number of sterile males released in the St. Marys River increased from 4,000 during 1991 to 1996 to 20,100 during 1997 to 1999. The theoretical reduc-stertion in reproduction when combined with trapping was 57% during 1991 to 1996 and 86% during 1997 to 1999. Evaluation studies demonstrated that sterilized males were competitive and reduced production of larvae in streams. Field studies and simulation models suggest reductions in reproduction will result in fewer recruits, but there is risk of periodic high recruitment events independent of sterile-male release. Strategies to reduce reproduction will be most reliable when low densities of reproducing females are achieved. Expansion of the technique is limited by access to additional males for sterilization. Sterile-male release and other alternative controls are important in delivering integrated pest management and in reducing reliance on pesticides.

  8. Effects of ethylene oxide sterilization on 82: 18 PLLA/PGA copolymer craniofacial fixation plates.

    Science.gov (United States)

    Pietrzak, William S

    2010-01-01

    Bioabsorbable devices are generally susceptible to some form of degradation or alteration of material properties in response to exposure to the terminal sterilization cycle. In addition to affecting the material strength, sterilization can also increase the rate of hydrolysis, both of which can impact clinical performance. The impact of sterilization on the material/device is unpredictable and must be empirically determined. This study examined the effects of ethylene oxide treatment on the material properties of LactoSorb 82:18 poly(L-lactic acid)-poly(glycolic acid) craniofacial plates. Compared with untreated control plates, there was no effect on the initial inherent viscosity (1.3 dL/g), the glass transition temperature (58 degrees C), or on the flexural mechanical properties. Furthermore, there was no effect on the in vitro rate of hydrolysis and mechanical strength loss profile. This provides evidence that the ethylene oxide sterilization cycle is compatible with these copolymer plates and that such treatment should not affect the clinical performance.

  9. Analysis and Tools for Improved Management of Connectionless and Connection-Oriented BLE Devices Coexistence.

    Science.gov (United States)

    Del Campo, Antonio; Cintioni, Lorenzo; Spinsante, Susanna; Gambi, Ennio

    2017-04-07

    With the introduction of low-power wireless technologies, like Bluetooth Low Energy (BLE), new applications are approaching the home automation, healthcare, fitness, automotive and consumer electronics markets. BLE devices are designed to maximize the battery life, i.e., to run for long time on a single coin-cell battery. In typical application scenarios of home automation and Ambient Assisted Living (AAL), the sensors that monitor relatively unpredictable and rare events should coexist with other sensors that continuously communicate health or environmental parameter measurements. The former usually work in connectionless mode, acting as advertisers, while the latter need a persistent connection, acting as slave nodes. The coexistence of connectionless and connection-oriented networks, that share the same central node, can be required to reduce the number of handling devices, thus keeping the network complexity low and limiting the packet's traffic congestion. In this paper, the medium access management, operated by the central node, has been modeled, focusing on the scheduling procedure in both connectionless and connection-oriented communication. The models have been merged to provide a tool supporting the configuration design of BLE devices, during the network design phase that precedes the real implementation. The results highlight the suitability of the proposed tool: the ability to set the device parameters to allow us to keep a practical discovery latency for event-driven sensors and avoid undesired overlaps between scheduled scanning and connection phases due to bad management performed by the central node.

  10. NF EN ISO 11137-1, July 2006. Sterilization of health care products - Irradiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices; NF EN ISO 11137-1, Juillet 2006. Sterilisation des produits de sante - Irradiation - Partie 1: exigences relatives a la mise au point, a la validation et au controle de routine d'un procede de sterilisation pour les dispositifs medicaux

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This part of the ISO 11137 standard specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices. Although the scope of this part of the ISO 11137 standard is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other products and equipment. This part of the international standard covers radiation processes employing irradiators using the radionuclide {sup 60}Co or {sup 137}Cs, a beam from an electron generator or a beam from an X-ray generator. This part of the international standard does not: - specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease; - detail specified requirements for designating a medical device as sterile; - specify a quality management system for the control of all stages of production of medical devices; - specify requirements for occupational safety associated with the design and operation of irradiation facilities; - specify requirements for the sterilization of used or reprocessed devices.

  11. Inactivation of animal and human prions by hydrogen peroxide gas plasma sterilization.

    Science.gov (United States)

    Rogez-Kreuz, C; Yousfi, R; Soufflet, C; Quadrio, I; Yan, Z-X; Huyot, V; Aubenque, C; Destrez, P; Roth, K; Roberts, C; Favero, M; Clayette, P

    2009-08-01

    Prions cause various transmissible spongiform encephalopathies. They are highly resistant to the chemical and physical decontamination and sterilization procedures routinely used in healthcare facilities. The decontamination procedures recommended for the inactivation of prions are often incompatible with the materials used in medical devices. In this study, we evaluated the use of low-temperature hydrogen peroxide gas plasma sterilization systems and other instrument-processing procedures for inactivating human and animal prions. We provide new data concerning the efficacy of hydrogen peroxide against prions from in vitro or in vivo tests, focusing on the following: the efficiency of hydrogen peroxide sterilization and possible interactions with enzymatic or alkaline detergents, differences in the efficiency of this treatment against different prion strains, and the influence of contaminating lipids. We found that gaseous hydrogen peroxide decreased the infectivity of prions and/or the level of the protease-resistant form of the prion protein on different surface materials. However, the efficiency of this treatment depended strongly on the concentration of hydrogen peroxide and the delivery system used in medical devices, because these effects were more pronounced for the new generation of Sterrad technology. The Sterrad NX sterilizer is 100% efficient (0% transmission and no protease-resistant form of the prion protein signal detected on the surface of the material for the mouse-adapted bovine spongiform encephalopathy 6PB1 strain and a variant Creutzfeldt-Jakob disease strain). Thus, gaseous or vaporized hydrogen peroxide efficiently inactivates prions on the surfaces of medical devices.

  12. Radiation sterilization

    International Nuclear Information System (INIS)

    Jacobs, G.P.

    1989-01-01

    In view of the application of ionizing radiation to sterilize pharmaceutical products, and the particular advantages of using this mode of sterilization for powders for injection, which cannot be sterilized by more conventional methods, it is important to recognise the possibility of modification of radiation response of bacteria when in close contact with various drug powders. For this study, bacterial spores, which lend themselves to dessication, and which can be dried onto an inert powder matrix, were chosen as the test system. The results of this work indicate that the additives tested have a modest protective effect on the spores. However, when considering a bacterial inactivation for sterilization purposes of between six and ten orders of magnitude, that is, a desired sterility assurance level of an expected maximum probability of a product item being non-sterile of 10 -6 , then the slight protective effect observed in this study approaches insignificance

  13. Prospects for radiation sterilization of medical products in Egypt

    International Nuclear Information System (INIS)

    Roushdy, H.M.

    1975-01-01

    The pharmaceutical industry in Egypt is continually expanding its activity and each year marks new accomplishments and additions which enable the companies to apply the most modern scientific means in the production of pharmaceutical preparations and consequently to improve their market potentialities. The certainty of expansion and the possibility of increasing exports of sterilized medical products, particularly to Arab and African countries, indicate a need for a gamma-sterilization plant. This technology permits the introduction of the latest practices with regard to used disposables, thus greatly reducing the chances of cross-contamination which usually results in serious complications enhanced by local environmental conditions. This paper reviews the current state and future prospects for radiation sterilization of medical products and biological tissues in connection with other related industrial radiation processings. Moreover, the paper reviews the Egyptian scientific and technical experience with irradiation facilities and the parameters underlying the choice of Egypt's first industrial gamma and electron-beam irradiators designed for more than a single-purpose use, with hygienic measures taken to avoid biological contamination of sterilized medical packages throughout the sterilization process. In addition, the paper deals with the policy set up for establishing the Egyptian National Centre for Radiation Technology with a view to introducing irradiation techniques in the sterilization of medical products, and to improving the properties and increasing the competitiveness of Egyptian fabrics. Apart from medical sterilization, certain industrial processes have been mentioned to show how a multi-purpose irradiation facility may be utilized in a developing country to justify significantly the large investment required. (author)

  14. The normal function of a speciation gene, Odysseus, and its hybrid sterility effect.

    Science.gov (United States)

    Sun, Sha; Ting, Chau-Ti; Wu, Chung-I

    2004-07-02

    To understand how postmating isolation is connected to the normal process of species divergence and why hybrid male sterility is often the first sign of speciation, we analyzed the Odysseus (OdsH) gene of hybrid male sterility in Drosophila. We carried out expression analysis, transgenic study, and gene knockout. The combined evidence suggests that the sterility phenotype represents a novel manifestation of the gene function rather than the reduction or loss of the normal one. The gene knockout experiment identified the normal function of OdsH as a modest enhancement of sperm production in young males. The implication of a weak effect of OdsH on the normal phenotype but a strong influence on hybrid male sterility is discussed in light of Haldane's rule of postmating isolation.

  15. Research on simulated devices for Solar photovoltaic grid-connected generation system

    Directory of Open Access Journals (Sweden)

    quan-zhu Zhang

    2017-01-01

    Full Text Available On the standpoint of energy conservation and emission reduction, one device simulated photovoltaic grid-connected generation system based on SPWM was designed in the paper. And DC/AC inverter could transduce efficiently direct current to alternating current. The MCU(Micro-Control-Unit, in this system could achieve the control method for maximum-power-point and tracking for frequency and phase. Moreover, the MCU could implement PWM (Plus-Width Modulating through programming. The system showed clearly the whole photovoltaic grid-connected generation system using simulated methods and ways.

  16. Sterile neutrino

    International Nuclear Information System (INIS)

    Anon.

    2007-01-01

    Paper deals with the information on the occurrence of the fields of the sterile neutrinos (the righthanded ones) mixed with the normal neutrinos (the lefthanded ones). Both the Max Plank Radioastronomy Institute and the Los Angeles University assumes that the occurrence of the keV mass sterile neutrinos may explain the dark matter nature, the fast rotation of the observed pulsars and the reionization processes. The issues associated with the possibility to record the sterile neutrinos were analyzed in the course of the Sterile Neutrinos in Astrophysics and Cosmology Workshop (Crans Montana, March 2006 [ru

  17. Gamma-sterilization

    International Nuclear Information System (INIS)

    Lindgren, E.

    1974-01-01

    The author makes a survey of his experience in sterilization and sterility control of medical products. At present three different methods are used, steamsterilization, gassterilizing and gammasterilizing. The investments and costs for gamma radiation is presented and a comparison of the costs for gamma- and gassterilization including sterility control is made. (M.S.)

  18. Genome-wide misexpression of X-linked versus autosomal genes associated with hybrid male sterility.

    Science.gov (United States)

    Lu, Xuemei; Shapiro, Joshua A; Ting, Chau-Ti; Li, Yan; Li, Chunyan; Xu, Jin; Huang, Huanwei; Cheng, Ya-Jen; Greenberg, Anthony J; Li, Shou-Hsien; Wu, Mao-Lien; Shen, Yang; Wu, Chung-I

    2010-08-01

    Postmating reproductive isolation is often manifested as hybrid male sterility, for which X-linked genes are overrepresented (the so-called large X effect). In contrast, X-linked genes are significantly under-represented among testis-expressing genes. This seeming contradiction may be germane to the X:autosome imbalance hypothesis on hybrid sterility, in which the X-linked effect is mediated mainly through the misexpression of autosomal genes. In this study, we compared gene expression in fertile and sterile males in the hybrids between two Drosophila species. These hybrid males differ only in a small region of the X chromosome containing the Ods-site homeobox (OdsH) (also known as Odysseus) locus of hybrid sterility. Of genes expressed in the testis, autosomal genes were, indeed, more likely to be misexpressed than X-linked genes under the sterilizing action of OdsH. Since this mechanism of X:autosome interaction is only associated with spermatogenesis, a connection between X:autosome imbalance and the high rate of hybrid male sterility seems plausible.

  19. Multiple matings among glossina and the sterile male technique

    International Nuclear Information System (INIS)

    Pinhao, R.C.

    1980-01-01

    The fact that multiple matings are a common phenomenon among glossina turns the sterile male technique into a competition not between adult insects but between two types of sperm, and the proportion of females inseminated with the one or the other is given by the binomial (p+q)sup(n), where p is the percentage of normal males, q the percentage of sterile males and n the average number of matings per female. However, multiple matings cannot damage the effectiveness of the technique unless two conditions are present either separately or simultaneously: precocious death of the spermatozoa and reduced inseminating potential among the sterile males. Study of the factors which can alter the inseminating potential is thus important for those who wish to use the sterile male technique. These factors are of three kinds: factors connected with quality, with quantity and with availability. The first are associated with the nature and intensity of the alterations brought about in the spermatozoa by the sterilizing agent, the second with possible variations in the amount of sperm reaching the spermotheca, the third with the behaviour of the sterile males in the nature - that is, the question whether sterilization has a favourable or unfavourable influence on their chances of mating with wild females. The author describes his observations of the quantity of sperm produced by Glossina morsitans submorsitans males from the colony reared at the Institute for Tropical Hygiene and Medicine in Lisbon, compares them with the observations of other authors and discusses their practical significance. Specific research is suggested. Advantages from assessing the behaviour of colonies not by female productivity but by male inseminating potential, and appropriate laboratory techniques

  20. Providing Re-Essure-ance to the Nickel-Allergic Patient Considering Hysteroscopic Sterilization.

    Science.gov (United States)

    Lane, Andrew; Tyson, Adam; Thurston, Erin

    2016-01-01

    Essure is a popular method of permanent sterilization that offers a minimally invasive approach that avoids the risks of traditional sterilization procedures in the operating room. Despite the rarity of complications, there has been concern in the popular media over the safety of Essure. We describe the third reported case of systemic contact dermatitis due to the nickel component of the device, with a resolution of symptoms following surgical removal of the inserts. Despite these cases, we believe that extremely rare complications such as this should not dissuade patients from choosing this safe, effective method of sterilization. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  1. A preliminary evaluation of a reusable digital sterilization indicator prototype.

    Science.gov (United States)

    Puttaiah, R; Griggs, J; D'Onofrio, M

    2014-09-01

    Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of sterilizers. Data loggers or independent digital parametric indicators are innovative devices that provide more information than various classes chemical indicators. In this study we evaluated a prototype of an independent digital parametric indicator's use in autoclaves. The purpose of this study was to evaluate the performance of an independent digital indicator/data logger prototype (DS1922F) that could be used for multiple cycles within an autoclave.MG Materials and methods: Three batches of the DS1922F (150 samples) were used in this study that was conducted in a series. The first batch was challenged with 300 sterilization cycles within an autoclave and the data loggers evaluated to study failures and the reason for failure, make corrections and improve the prototype design. After changes made based on studying the first batch, the second batch of the prototype (150 samples) were challenged once again with 300 sterilization cycles within an autoclave and failure studied again in further improvement of the prototype. The final batch (3rd batch) of the prototype (150 samples) was challenged again but with 600 cycles to see how long they would last. Kaplan-Meier survival analysis analyses of all three batches was conducted (α = 0.05) and failed samples qualitatively studied in understanding the variables involved in the failure of the prototype, and in improving quality. Each tested batch provided crucial information on device failure and helped in improvement of the prototype. Mean lifetime survival of the final batch (Batch 3) of prototype was 498 (480, 516) sterilization cycles

  2. Sterilization by ionizing radiation comparative evaluation; Sterilizzazione mediante radiazioni e confronto con le tecniche convenzionali

    Energy Technology Data Exchange (ETDEWEB)

    Tata, A. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dip. Innovazione; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 70 % by EtO, 27% by gamma-irradiation and 3% using accelerated beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems.

  3. The Use of Tygon Tubing Sterilized by Gamma Radiation in Heart-Lung By-Pass Machines

    Energy Technology Data Exchange (ETDEWEB)

    Alladine, M. F.; Gibbons, J. R. P. [London Chest Hospital, London (United Kingdom)

    1967-09-15

    Tygon tubing is a co-polymer polyvinyl chloride. This tubing is used throughout the circuit of our heart-lung by-pass machines and had been sterilized by autoclaving or exposure to ethylene oxide gas. Tubing sterilized by autoclaving was noted to have a decrease in tensile strength and the transparency of the tubing was affected. Sterilization by ethylene oxide had the disadvantage that gas was often present in the lumen of the tube when connected to the machine. Lengths of Tygon tubing were sterilized by gamma radiation at varying radiation levels and temperatures. Bacteriological studies were done on the tubing and estimation of tensile strength carried out. We have found that a level of radiation of 2. 5 to 3. 0 Mrad at 20°C produces little or no change in tensile strength and the tubing remains bacteriologically sterile. Tygon tubing sterilized in this way has now been used in over sixty heart-lung by-pass machine operations. (author)

  4. Energy monitoring device for 1.5-2.4 MeV electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Fuochi, P.G., E-mail: fuochi@isof.cnr.i [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Lavalle, M.; Martelli, A. [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Kovacs, A. [Institute of Isotopes, HAS, P.O.Box 77, H-1525 Budapest (Hungary); Mehta, K. [Arbeiterstrandbad Strasse 72, Vienna, A-1210 (Austria); Kuntz, F.; Plumeri, S. [Aerial, Parc d' Innovation Rue Laurent Fries F-67400 Illkirch (France)

    2010-03-11

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  5. Energy monitoring device for 1.5-2.4 MeV electron beams

    Science.gov (United States)

    Fuochi, P. G.; Lavalle, M.; Martelli, A.; Kovács, A.; Mehta, K.; Kuntz, F.; Plumeri, S.

    2010-03-01

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  6. Radiation as a microbiological contamination control of drugs, cosmetics and medical devices

    International Nuclear Information System (INIS)

    Ishizeki, Chuichi

    1985-01-01

    This paper deals with current status of radiation sterilization or disinfection of drugs, cosmetics, their materials, and medical devices, and with quality control as a tool for securing microbiological safety, especially current status of sterilization tests. Ointment containing tetracyclin, steroid hormones, gelatin, and enzymes are presented as drug samples to be irradiated, and explanations for radiation sterilization of these drugs are provided. An outline of the application of radiation in cosmetics and medical devices is given. Issues are also provided from the viewpoint of safey and effectiveness of radiation sterilization. (Namekawa, K.)

  7. [Assessment of disinfection and sterilization processes in dental practice as an important factors in prevention of infections].

    Science.gov (United States)

    Podgórska, Marta; Jakimiak, Bozenna; Röhm-Rodowald, Ewa; Chojecka, Agnieszka

    2009-01-01

    The dental health-care settings is an environment where disease transmission occurs easily. Prevention of cross infection is therefore a crucial aspect of dental practice and dental clinic stuffmust adopt certain basic routines while practicing. Infections may be transmitted in the dental operatory through direct contact with blood, oral fluids or other secretions; via indirect contact with contaminated instruments, equipment or environmental surfaces; or by contact with airborne contaminants present in either droplet splatter or aerosols of oral and respiratory fluids. Strategies to prevent dental patient infections have focused on disinfection and sterilization. This study evaluates basic routines in prevention of cross-infection in the dentistry. The sample comprised 100 dentists, who completed questionnaires. Based on inquires the conditions for disinfection and sterilization of medical devices were assessed. The following issues were taken into consideration: the way of disinfection and preparation of the disinfectants, the localization of disinfection, preparing to disinfection, washing and packing of dental devices, the frequency of disinfection, methods of sterilization and the monitoring system, type of sterilizers and the available cycles. The dental practices are well equiped to proceed the steam sterilization, but 33% of dentists don't know the available cycles in their autoclaves. Only 35% of them made sterilization process protocols. Very common are three failures of instruments disinfections: multiple use of disinfectant, adding of disinfectant, adding new instruments. There is still need for improvement in disinfection and sterilization in dental practice, especially including: monitoring and documentation of sterilization process, proper use of disinfectants according to manufactures instructions, frequent disinfection of surfaces which contact with patients. Dental stuff should take part in advanced training courses about disinfection and

  8. Low temperature gamma sterilization of a bioresorbable polymer, PLGA

    Science.gov (United States)

    Davison, Lisa; Themistou, Efrosyni; Buchanan, Fraser; Cunningham, Eoin

    2018-02-01

    Medical devices destined for insertion into the body must be sterilised before implantation to prevent infection or other complications. Emerging biomaterials, for example bioresorbable polymers, can experience changes in their properties due to standard industrial sterilization processes. Gamma irradiation is one of the most reliable, large scale sterilization methods, however it can induce chain scission, cross-linking or oxidation reactions in polymers. sterilization at low temperature or in an inert atmosphere has been reported to reduce the negative effects of gamma irradiation. The aim of this study was to investigate the impact of low temperature sterilization (at -80 °C) when compared to sterilization at ambient temperature (25 °C) both in inert atmospheric conditions of nitrogen gas, on poly(lactide co-glycolide) (PLGA). PLGA was irradiated at -80 and 25 °C at 40 kGy in a nitrogen atmosphere. Samples were characterised using differential scanning calorimetry (DSC), tensile test, Fourier transform infrared (FTIR) spectroscopy, proton nuclear magnetic resonance (1H NMR) spectroscopy and gel permeation chromatography (GPC). The results showed that the molecular weight was significantly reduced as was the glass transition temperature, an indication of chain scission. FTIR showed small changes in chemical structure in the methyl and carbonyl groups after irradiation. Glass transition temperature was significantly different between irradiation at -80 °C and irradiation at 25 °C, however this was a difference of only 1 °C. Ultimately, the results indicate that the sterilization temperature used does not affect PLGA when carried out in a nitrogen atmosphere.

  9. Research on Experiment of Islanding Protection Device of Grid-connected Photovoltaic System Based on RTDS

    Science.gov (United States)

    Zhou, Ning; Yang, Jia; Cheng, Zheng; Chen, Bo; Su, Yong Chun; Shu, Zhan; Zou, Jin

    2017-06-01

    Solar photovoltaic power generation is the power generation using solar cell module converting sunlight into DC electric energy. In the paper an equivalent model of solar photovoltaic power generation system is built in RTDS. The main circuit structure of the two-stage PV grid-connected system consists of the DC-DC, DC-AC circuit. The MPPT (Maximum Power Point Tracking) control of the PV array is controlled by adjusting the duty ratio of the DC-DC circuit. The proposed control strategy of constant voltage/constant reactive power (V/Q) control is successfully implemented grid-connected control of the inverter when grid-connected operation. The closed-loop experiment of islanding protection device of photovoltaic power plant on RTDS, verifies the correctness of the simulation model, and the experimental verification can be applied to this type of device.

  10. Device for welding a connection line to an electrode of a solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Lorans, D.Y.

    1976-08-05

    A method with associated device for welding connection lines to the electrodes of solar cells is described. To improve the weldability of the contacts usually consisting of silver, a weld-receiving device is vibrated with respect to the welding electrode, whereby disturbing surface layers are destroyed with a certain application pressure of the welding electrode. The method shows better results than, for example, a previous chemical cleaning of the contacts and is also more easy to handle.

  11. Radiation sterilization of livestock feeds

    International Nuclear Information System (INIS)

    Kawashima, Koji

    1984-01-01

    The radiation sterilization of livestock feeds is not much used presently because the process is not known well, and the cost is relatively high. However, its effect of sterilization is absolute, the radiation-sterilized feeds are safe in both nutrition and toxicity, and do not affect the appetite of livestocks, and the radiation energy required is small. In the future, as in the sterilization of medical supplies, feed radiation sterilization plants should be established, to stabilize livestock industry and to contribute to the health control of experimental animals. The following matters are described: radiation, comparison between radiation sterilization and other sterilization methods, the practice of feed radiation sterilization, the adverse effects of radiation sterilization, economic aspect, and the situation of feed radiation sterilization in various countries. (Mori, K.)

  12. Short Paper: Frequency Regulation Services from Connected Residential Devices: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Kyri; Jin, Xin; Vaidhynathan, Deepthi; Jones, Wesley; Christensen, Dane; Sparn, Bethany; Woods, Jason; Sorensen, Harry; Lunacek, Monte

    2017-01-01

    In this paper, we demonstrate the potential benefits that residential buildings can provide for frequency regulation services in the electric power grid. In a hardware-in-the- loop (HIL) implementation, simulated homes along with a physical laboratory home are coordinated via a grid aggregator, and it is shown that their aggregate response has the potential to follow the regulation signal on a timescale of seconds. Connected (communication-enabled), devices in the National Renewable Energy Laboratory's (NREL's) Energy Systems Integration Facility (ESIF) received demand response (DR) requests from a grid aggregator, and the devices responded accordingly to meet the signal while satisfying user comfort bounds and physical hardware limitations. Future research will address the issues of cybersecurity threats, participation rates, and reducing equipment wear-and-tear while providing grid services.

  13. Inherited sterility in insects

    International Nuclear Information System (INIS)

    Carpenter, J.E.; Marec, F.; Bloem, S.

    2005-01-01

    The unique genetic phenomena responsible for inherited sterility (IS) in Lepidoptera and some other arthropods, as compared with full sterility, provide advantages for pest control. Lepidopteran females are usually more sensitive to radiation than males of the same species. This allows the radiation dose to be adjusted to suit programme requirements. When partially sterile males mate with wild females, the radiation-induced deleterious effects are inherited by the F 1 generation. As a result, egg hatch is reduced and the resulting offspring are both highly sterile and predominately male. Compared with the high radiation required to achieve full sterility in Lepidoptera, the lower dose of radiation used to induce F 1 sterility increases the quality and competitiveness of the released insects as measured by improved dispersal after release, increased mating ability, and superior sperm competition. F 1 sterile progeny produced in the field enhance the efficacy of released partially sterile males, and improve compatibility with other pest control strategies. In addition, F 1 sterile progeny can be used to increase the production of natural enemies, and to study the potential host and geographical ranges of exotic lepidopteran pests. (author)

  14. Coupling active and sterile neutrinos in the cosmon plus seesaw framework

    International Nuclear Information System (INIS)

    Bernardini, A.E.

    2010-01-01

    The cosmological evolution of neutrino energy densities driven by cosmon-type field equations is introduced assuming that active and sterile neutrinos are intrinsically connected by cosmon fields through the seesaw mechanism. Interpreting sterile neutrinos as dark matter adiabatically coupled with dark energy results in a natural decoupling of (active) mass varying neutrino (MaVaN) equations. Identifying the dimensionless scale of the seesaw mechanism, m/M, with a power of the cosmological scale factor, a, allows for embedding the resulting masses into the generalized Chaplygin gas (GCG) scenario for the dark sector. Without additional assumptions, our findings establish a precise connection among three distinct frameworks: the cosmon field dynamics for MaVaN's, the seesaw mechanism for dynamical mass generation and the GCG scenario. Our results also corroborate with previous assertions that mass varying particles can be the right responsible for the stability issue and for the cosmic acceleration of the universe.

  15. Radiation sterilization of polymeric implant materials

    International Nuclear Information System (INIS)

    Bruck, S.D.; Mueller, E.P.

    1988-01-01

    High-energy irradiation sterilization of medical devices and implants composed of polymeric biomaterials that are in contact with tissue and/or blood, may adversely affect their long-term mechanical and/or biological performance (tissue and/or blood compatibility). Since many polymeric implants may contain trace quantities of catalysts and/or other additives, the effect of high-energy radiation on these additives, and possible synergistic effects with the polymer chains under the influence of high-energy radiation, must be considered. It is essential to indicate whether polymeric implants are used in short-term (acute) or long-term (chronic) applications. Relatively small changes in their physicochemical, mechanical, and biological properties may be tolerable in the short term, whereas similar changes may lead to catastrophic failures in long-term applications. Therefore, polymeric implants which are to be sterilized by high-energy irradiation should be carefully evaluated for long-term property changes which may be induced by the radiation

  16. Dose mapping for documentation of radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1999-01-01

    The radiation sterilization standards EN 552 and ISO 11137 require that dose mapping in real or simulated product be carried in connection with the process qualification. This paper reviews the recommendations given in the standards and discusses the difficulties and limitations of practical dose...... mapping. The paper further gives recommendations for effective dose mapping including traceable dosimetry, documented procedures for placement of dosimeters, and evaluation of measurement uncertainties. (C) 1999 Elsevier Science Ltd. All rights reserved....

  17. Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes.

    Science.gov (United States)

    Winter, S; Smith, A; Lappin, D; McDonagh, G; Kirk, B

    2017-12-01

    Dental handpieces are required to be sterilized between patient use. Vacuum steam sterilization processes with fractionated pre/post-vacuum phases or unique cycles for specified medical devices are required for hollow instruments with internal lumens to assure successful air removal. Entrapped air will compromise achievement of required sterilization conditions. Many countries and professional organizations still advocate non-vacuum sterilization processes for these devices. To investigate non-vacuum downward/gravity displacement, type-N steam sterilization of dental handpieces, using thermometric methods to measure time to achieve sterilization temperature at different handpiece locations. Measurements at different positions within air turbines were undertaken with thermocouples and data loggers. Two examples of widely used UK benchtop steam sterilizers were tested: a non-vacuum benchtop sterilizer (Little Sister 3; Eschmann, Lancing, UK) and a vacuum benchtop sterilizer (Lisa; W&H, Bürmoos, Austria). Each sterilizer cycle was completed with three handpieces and each cycle in triplicate. A total of 140 measurements inside dental handpiece lumens were recorded. The non-vacuum process failed (time range: 0-150 s) to reliably achieve sterilization temperatures within the time limit specified by the international standard (15 s equilibration time). The measurement point at the base of the handpiece failed in all test runs (N = 9) to meet the standard. No failures were detected with the vacuum steam sterilization type B process with fractionated pre-vacuum and post-vacuum phases. Non-vacuum downward/gravity displacement, type-N steam sterilization processes are unreliable in achieving sterilization conditions inside dental handpieces, and the base of the handpiece is the site most likely to fail. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Slide release mechanism. [for space shuttle orbiter/external tank connection device

    Science.gov (United States)

    Bunker, J. W.; Ritchie, R. S. (Inventor)

    1985-01-01

    A releasable support device is described which is comprised of a hollow body with a sleeve extending transversely there-through for receiving the end of a support shank. A slider-latch, optionally lubricated, extends through side recesses in the sleeve to straddle the shank, respectively, in latched and released positions. The slider-latch is slid from its latched to its unlatched position by a pressure squib whereupon a spring or other pressure means pushes the shank out of the sleeve. At the same time, a follower element is lodged in and closed the hole in the body wall from which the shank was discharged. The mechanism was designed for the shuttle orbiter/external tank connection device.

  19. [Connective tissue and inflammation].

    Science.gov (United States)

    Jakab, Lajos

    2014-03-23

    The author summarizes the structure of the connective tissues, the increasing motion of the constituents, which determine the role in establishing the structure and function of that. The structure and function of the connective tissue are related to each other in the resting as well as inflammatory states. It is emphasized that cellular events in the connective tissue are part of the defence of the organism, the localisation of the damage and, if possible, the maintenance of restitutio ad integrum. The organism responds to damage with inflammation, the non specific immune response, as well as specific, adaptive immunity. These processes are located in the connective tissue. Sterile and pathogenic inflammation are relatively similar processes, but inevitable differences are present, too. Sialic acids and glycoproteins containing sialic acids have important roles, and the role of Siglecs is also highlighted. Also, similarities and differences in damages caused by pathogens and sterile agents are briefly summarized. In addition, the roles of adhesion molecules linked to each other, and the whole event of inflammatory processes are presented. When considering practical consequences it is stressed that the structure (building up) of the organism and the defending function of inflammation both have fundamental importance. Inflammation has a crucial role in maintaining the integrity and the unimpaired somato-psychological state of the organism. Thus, inflammation serves as a tool of organism identical with the natural immune response, inseparably connected with the specific, adaptive immune response. The main events of the inflammatory processes take place in the connective tissue.

  20. [Sterilization and eugenics].

    Science.gov (United States)

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  1. Sharing Data between Mobile Devices, Connected Vehicles and Infrastructure Task 12 : D2X Hub Prototype Field Test, Evaluation Plan and Results.

    Science.gov (United States)

    2017-10-25

    Sharing Data between Mobile Devices, Connected Vehicles and Infrastructure was a U.S. DOT-sponsored research project to study the integration of mobile devices (such as smartphones) into the Connected Vehicle (CV) environment. Objectives includ...

  2. Reversibility of female sterilization.

    Science.gov (United States)

    Siegler, A M; Hulka, J; Peretz, A

    1985-04-01

    The discussion considers the current status of reversibility of sterilization in the US and describes clinical and experimental efforts for developing techniques designed for reversibility. It focuses on regret following sterilization, reversal potential of current sterilization techniques, patient selection, current reversal techniques, results of sterilization procedures, experimental approaches to reversal of current techniques of sterilization, and sterilization procedures devised for reversibility, in humans and in animals. Request is the 1st stage of reversal, but a request for sterilization reversal (SR) does not always mean regret for a decision made at the time. Frequently it is a wish to restore fertility because life circumstances have changed after a sterilization that was ppropriate at the time it was performed. Schwyhart and Kutner reviewed 22 studies published between 1949-69 in which they found that the percentage of patients regretting the procedure ranged from 1.3-15%. Requests for reversal remain low in most countries, but if sterilization becomes a more popular method of contraception, requests will also increase. The ideal operation considered as a reversaible method of sterilization should include an easy, reliable outpatient method of tubal occlusion with miniml risk or patient discomfort that subsequently could be reversed without the need for a major surgical intervention. Endoscopic methods have progressed toward the 1st objective. A recent search of the literature uncovered few series of SR of more than 50 cases. The 767 operations found were analyzed with regard to pregnancy outcome. The precent of live births varied from 74-78.8%, and the occurance of tubal pregnancies ranged from 1.7-6.5%. All of the confounding variables in patient selection and small numbers of reported procedures preclude any conclusion about the different techniques or the number of operations that give a surgeon a level of expertise. Few authors classify their

  3. [Current status of disinfection and sterilization for dental handpieces in the hospitals].

    Science.gov (United States)

    Deng, Xiao-hong; Sun, Zheng; Su, Jing

    2004-11-01

    To understand current status of the uses of dental handpieces, methods of disinfection and sterilization and their effectiveness in dental-care hospitals and out-patient departments of stomatology in general hospitals. Ten dental-care hospitals and departments of stomatology in general hospitals at varied levels were randomly sampled during 2000 to 2001 to investigate the uses of dental handpieces and means of their disinfection and sterilization. One used dental handpiece from each hospital or department of stomatology in general hospital selected was detected for possible contamination of bacteria by aerobic bacterial count and Coliform bacterial examinations and hepatitis B surface antigen (HBsAg) on it, based on "The Technical Standards for Disinfection" set by the Ministry of Health of China, and the effectiveness of its disinfection and sterilization was evaluated as well. Anti-suction handpieces were used only in 5.9% of the hospitals or departments, 94.1% of them without anti-suction devices. Cleansing disinfection was applied for used dental handpieces in 62.9% of the dental-care hospitals and the departments of stomatology, with an effective rate of 26.17%, immersing disinfection in 10.0%, with an effective rate of 55.88%, and autoclave in 27.1%, with an effective rate of 80.43%. Used dental handpieces in the hospitals and departments of stomatology in general hospitals were all contaminated by bacteria and HBsAg could be detected in 1.67% of them. Dental handpieces without anti-suction should be replaced soon by those with it or comprehensive dental unit with anti-suction device should be used. Used dental handpieces must be sterilized effectively before next use. Awareness on prevention from cross-infection should be improved for dental-care professional staff and operation of sterilization should be standardized.

  4. Radiation sterilization of medical products

    International Nuclear Information System (INIS)

    Khurshid, S.J.; Hussain, A.M.

    1989-01-01

    Radiation sterilization is the best method of sterilization, essentially for single use medical and surgical products. Pakistan has established a commercial gamma irradiation plant for this purpose. This article overviews the advantages and benefits of radiation sterilization to stimulate the interest of industrialists and the users in this technology. This technology can give a better medical care in the country and the growing demand can only be met by bulk sterilization. The radiation sterilized medical products can also compete well with the products sterilized by other methods in the international market, gamma sterilization is accepted internationally and if adopted it can boost our export of medical products. (author)

  5. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  6. Methods of sterilization and monitoring of sterilization across selected dental practices in karachi, pakistan

    International Nuclear Information System (INIS)

    Ahmed, H.

    2015-01-01

    To assess methods of sterilization in dental practices in Karachi and secondly to investigate methods of monitoring sterilization in dental practices in Karachi, Pakistan. Study Design: Cross-sectional, descriptive study. Place and Duration of Study: Dental colleges, hospitals and private clinics of Karachi, Pakistan, from January to March 2013. Methodology: A total of 251 questionnaires were obtained. Descriptive statistics were computed and differences between groups were assessed through chi-square test using Statistical Package for the Social Sciences (SPSS) version 16.0. P-value < 0.05 was taken as statistically significant. Results: Autoclave, used by 155 (61.8%) dentists was the most common method of sterilization followed by more than one method, 65 (25.9%); dry heat, 24 (9.6%); and cold sterilization, 7 (2.8%). Majority of dentists, 126 (50.1%), never monitored sterilization and those who did monitored mostly monthly. Statistically significant difference was found amongst the three groups of dentists monitoring sterilization (p=0.09) and methods of sterilization (p < 0.01). Conclusion: Statistically significant difference was found in infection control practices of specialists, postgraduate trainees and general dentists regarding method of monitoring sterilization with majority of dentists never monitoring sterilization. (author)

  7. Study of consumer attitudes towards connected reader devices in Japan based on the decomposed Theory of Planned Behavior

    OpenAIRE

    Koeder, Marco Josef; Mohammed, Upal; Sugai, Philip

    2011-01-01

    Some of the most interesting developments within mobile and wireless technologies have evolved from an enhancement of our daily life; creating objects and technologies that we can consume to hopefully increase our quality of life. Lately, a new (mobile) convergence is underway globally with new embedded connected devices entering the markets such as the iPad, the Galaxy tablet and dedicated connected reader devices such as Kindle, Librie and the biblio Leaf SP02 launched by KDDI in Japan. The...

  8. Mobile Device Applications for the Visualization of Functional Connectivity Networks and EEG electrodes: iBraiN and iBraiNEEG.

    Directory of Open Access Journals (Sweden)

    Gonzalo Mauricio Rojas

    2016-10-01

    Full Text Available Multiple fMRI-based functional connectivity networks were obtained by Yeo et al., and the visualization of these complex networks is a difficult task. Also, the combination of functional connectivity networks determined by fMRI with EEG data could be a very useful tool. Mobile devices are becoming increasingly common among users, and for this reason, we describe here two applications for Android and iOS mobile devices: one that shows in an interactive way the seven Yeo functional connectivity networks, and another application that shows the relative position of 10-20 EEG electrodes with Yeo’s seven functional connectivity networks.

  9. Mobile Device Applications for the Visualization of Functional Connectivity Networks and EEG Electrodes: iBraiN and iBraiNEEG.

    Science.gov (United States)

    Rojas, Gonzalo M; Fuentes, Jorge A; Gálvez, Marcelo

    2016-01-01

    Multiple functional MRI (fMRI)-based functional connectivity networks were obtained by Yeo et al. (2011), and the visualization of these complex networks is a difficult task. Also, the combination of functional connectivity networks determined by fMRI with electroencephalography (EEG) data could be a very useful tool. Mobile devices are becoming increasingly common among users, and for this reason, we describe here two applications for Android and iOS mobile devices: one that shows in an interactive way the seven Yeo functional connectivity networks, and another application that shows the relative position of 10-20 EEG electrodes with Yeo's seven functional connectivity networks.

  10. APSIC guidelines for disinfection and sterilization of instruments in health care facilities

    Directory of Open Access Journals (Sweden)

    Moi Lin Ling

    2018-02-01

    Full Text Available Abstract Background The Asia Pacific Society of Infection Control launched its revised Guidelines for Disinfection and Sterilization of Instruments in Health Care Facilities in February 2017. This document describes the guidelines and recommendations for the reprocessing of instruments in healthcare setting. It aims to highlight practical recommendations in a concise format designed to assist healthcare facilities at Asia Pacific region in achieving high standards in sterilization and disinfection. Method The guidelines were revised by an appointed workgroup comprising experts in the Asia Pacific region, following reviews of previously published guidelines and recommendations relevant to each section. Results It recommends the centralization of reprocessing, training of all staff with annual competency assessment, verification of cleaning, continual monitoring of reprocessing procedures to ensure their quality and a corporate strategy for dealing with single-use and single-patient use medical equipment/devices. Detailed recommendations are also given with respect to reprocessing of endoscopes. Close working with the Infection Prevention & Control department is also recommended where decisions related to reprocessing medical equipment/devices are to be made. Conclusions Sterilization facilities should aim for excellence in practices as this is part of patient safety. The guidelines that come with a checklist help service providers identify gaps for improvement to reach this goal.

  11. Audits of radiation sterilization facilities

    International Nuclear Information System (INIS)

    Kelkar, Prabhakar M.

    2001-01-01

    Johnson and Johnson is the world leader in sterilization science and technology. A special group of scientists and technologists are engaged in the development of new methods of sterilization, worldwide monitoring of sterilization processes, equipment and approvals for all types of sterilization processes. Kilmer Conference in the alternate year for the benefit of all those involved in improvement in sterilization science is held. Cobalt-60 gamma radiation for sterilization of medical products on commercial scale is used. This kind of mammoth task can only be achieved through systematic method of planning, auditing, expert review and approval of facilities

  12. Male and female sterility in Zambia

    Directory of Open Access Journals (Sweden)

    Athena Pantazis

    2014-02-01

    Full Text Available Background: Population measures of sterility are traditionally constructed for women, despite fertility and sterility being conditions of the couple. Estimates of male sterility provide insight into population-level sterility, and complement estimates based solely on women. Objective: This study seeks to estimate male sterility for the Gwembe Tonga of Zambia using male birth histories collected by the Gwembe Tonga Research Project from 1957 to 1995, while providing context by estimating female sterility for the Gwembe Tonga, as well as female sterility in all of Zambia, from Zambian DHS data (1992, 1997, 2001-02, and 2007. Methods: Sterility is measured using the Larson-Menken subsequently infertile indicator. Estimates are produced using discrete time event history analysis. Results: The odds of sterility were higher for women than men, though women's odds of sterility were only 1.5 times that of men's in the middle reproductive years. The odds of sterility increased steadily with age for both men and women, and across all datasets. However, women's sterility increased much more sharply with age than men's did, and women's odds of sterility were higher than men's at all reproductive ages.

  13. Laparoscopic female sterilization.

    Science.gov (United States)

    Filshie, G M

    1989-09-01

    An overview of laparoscopic sterilization techniques from a historical and practical viewpoint includes instrumentation, operative techniques, mechanical occlusive devices, anesthesia, failure rates, morbidity and mortality. Laparoscope was first reported in 1893, but was developed simultaneously in France, Great Britain, Canada and the US in the 1960s. There are smaller laparoscopes for double-puncture procedures, and larger, single-puncture laparoscopes. To use a ring or clip, a much larger operating channel, up to 8 mm is needed. Insufflating gas may be CO2, which does not support combustion, but is more uncomfortable, NO2, which is also an anesthetic, and room air often used in developing countries. Unipolar electrocautery is now rarely used, in fact most third party payers do not allow it. Bipolar cautery, thermal coagulation and laser photocoagulation are safer methods. Falope rings, Hulka-Clemens, Filshie, Bleier, Weck and Tupla clips are described and illustrated. General anesthesia, usually a short acting agent with a muscle relaxant, causes 33% of the mortality of laparoscope, often due to cardiac arrest and arrhythmias, preventable with atropine. Local anesthesia is safer and cheaper and often used in developing countries. Failure rates of the various laparoscopic tubal sterilization methods are reviewed: most result from fistula formation. Mortality and morbidity can be caused by bowel damage, injury or infection, pre- existing pelvic infection, hemorrhage, gas embolism (avoidable by the saline drip test), and other rare events.

  14. Radiation induced male sterility in Hevea brasiliensis (Willd. ex Adr. De Juss. ) muell. arg

    Energy Technology Data Exchange (ETDEWEB)

    Saraswathy Amma, C K; Panikkar, A O.N.; Sethuraj, M R [Rubber Research Inst. of India, Kottayam, Kerala (India). Botany Div.; Namboodiri, A N

    1990-12-01

    A plant exhibiting semi-dwarf stature was identified from a gamma ray induced VM{sub 7} population. Cytomixis was observed in 30 % of the meiocytes. Cytoplasmic connections were observed in all stages of PMCs ranging from early prophase stage to microspore stage. Movement of chromatin materials was also observed. A wide spectrum of cytokinetic aberrations was also noted. As a result of these abnormalities the plant showed total male sterility. In Hevea, male sterility can be exploited for the production of hybrid seeds and dwarf stature in breeding programme. (author).

  15. Radiation induced male sterility in Hevea brasiliensis (Willd. ex Adr. De Juss.) muell. arg

    International Nuclear Information System (INIS)

    Saraswathy Amma, C.K.; Panikkar, A.O.N.; Sethuraj, M.R.; Namboodiri, A.N.

    1990-01-01

    A plant exhibiting semi-dwarf stature was identified from a gamma ray induced VM 7 population. Cytomixis was observed in 30 % of the meiocytes. Cytoplasmic connections were observed in all stages of PMCs ranging from early prophase stage to microspore stage. Movement of chromatin materials was also observed. A wide spectrum of cytokinetic aberrations was also noted. As a result of these abnormalities the plant showed total male sterility. In Hevea, male sterility can be exploited for the production of hybrid seeds and dwarf stature in breeding programme. (author)

  16. The smart aerial release machine, a universal system for applying the sterile insect technique.

    Directory of Open Access Journals (Sweden)

    Ruben Leal Mubarqui

    Full Text Available Beyond insecticides, alternative methods to control insect pests for agriculture and vectors of diseases are needed. Management strategies involving the mass-release of living control agents have been developed, including genetic control with sterile insects and biological control with parasitoids, for which aerial release of insects is often required. Aerial release in genetic control programmes often involves the use of chilled sterile insects, which can improve dispersal, survival and competitiveness of sterile males. Currently available means of aerially releasing chilled fruit flies are however insufficiently precise to ensure homogeneous distribution at low release rates and no device is available for tsetse.Here we present the smart aerial release machine, a new design by the Mubarqui Company, based on the use of vibrating conveyors. The machine is controlled through Bluetooth by a tablet with Android Operating System including a completely automatic guidance and navigation system (MaxNav software. The tablet is also connected to an online relational database facilitating the preparation of flight schedules and automatic storage of flight reports. The new machine was compared with a conveyor release machine in Mexico using two fruit flies species (Anastrepha ludens and Ceratitis capitata and we obtained better dispersal homogeneity (% of positive traps, p<0.001 for both species and better recapture rates for Anastrepha ludens (p<0.001, especially at low release densities (<1500 per ha. We also demonstrated that the machine can replace paper boxes for aerial release of tsetse in Senegal.This technology limits damages to insects and allows a large range of release rates from 10 flies/km2 for tsetse flies up to 600,000 flies/km2 for fruit flies. The potential of this machine to release other species like mosquitoes is discussed. Plans and operating of the machine are provided to allow its use worldwide.

  17. Investigation of initial contamination for disposal medical infusion items and determination of sterilization dose

    International Nuclear Information System (INIS)

    Hu Jinhui; Xu Ziyan; Sun Naifeng; Yan Aoshuang; Gao Wei; Wang Binglin

    1993-01-01

    Statistical analyses on initial contamination of 624 disposal medical infusion items are made. The normal distribution of the initial contamination, the relation of initial contamination of inner and outer walls of disposal medical infusion items and the changes of initial contamination before irradiation are shown. The sterilized dose for disposal infusion is determined as 17.2 kGy using bioburden information. The SAL (sterility assurance level) dose is 10 6 . The SIP (device sample item proportion) is 1 and the average initial contamination is 7 CFU/item

  18. Assessment of Color Changes in Vita 3D-Master Shade Guide after Sterilization and Disinfection

    Directory of Open Access Journals (Sweden)

    Hossein Dashti

    2017-06-01

    Full Text Available Purpose:Dental shade guides are commonly used for color determination and should be disinfected and sterilized. The purpose of this study was to evaluate the color change of Vita 3D Master shade tabs after disinfection and sterilization. Material and methods:Overall, 98 samples (shade tabs were randomly selected from 14 new, unused Vita 3D sets, including the following shades: 2M1, 3L1.5, 3M1, 3M2, 3M3, 3R1.5 and 4M1. In each set, values of 2, 3 and 4, chroma of 1, 2 and 3 and hue were selected for the comparison of different shades. All tabs were measured using the Vita Easyshade device at baseline. The first group was disinfected with Deconex and the second group was sterilized by autoclaving in a simulated annual application. All the tabs were measured again using the same device. This process was repeated to simulate 2 and 3 years of usage. Statistical analysis was conducted by repeated measures analysis of variance (ANOVA and independent t-test and paired sample t-test. Results:In the disinfected group, we observed significant differences in value and chroma in all periods (p˂0.001. However, hue showed no significant difference after the first year of simulated treatment (p=0.527, though it was significantly different in the second and third simulations (p˂0.001. In the sterilized group, all variables showed a significant difference for each year (p˂0.05. Considering total color difference (ΔE, there was a significant difference between the two groups in the first, second and third simulated years; ΔE increased in the sterilized group more than in the disinfected samples (p˂0.001.  Conclusions:  The color change of shade tabs was significant both after disinfection by a chemical solution and by sterilization through autoclaving. However, although disinfectants may not have a clinically important effect, sterilization should be considered as an interfering factor during color-matching procedure.

  19. Dosimetric studies for gamma radiation validation of medical devices

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Beshir, W.B.; Abdel-Fattah, A.A.; Abdel-Rehim, F.

    2013-01-01

    The delivery and validation of a specified dose to medical devices are key concerns to operators of gamma radiation facilities. The objective of the present study was to characterize the industrial gamma radiation facility and map the dose distribution inside the product-loading pattern during the validation and routine control of the sterilization process using radiochromic films. Cardboard phantoms were designed to achieve the homogeneity of absorbed doses. The uncertainty of the dose delivered during validation of the sterilization process was assessed. - Highlights: ► Using γ-rays for sterilization of hollow fiber dialyzers and blood tubing sets according to ISO 11137, 2006. ► Dosimetry studies of validations of γ-irradiation facility and sterilized medical devices. ► Places of D min and D max have been determined using FWT-60 films. ► Determining the target minimum doses required to meet the desired SAL of 10 −6 for the two products.

  20. Development of Simulink-Based SiC MOSFET Modeling Platform for Series Connected Devices

    DEFF Research Database (Denmark)

    Tsolaridis, Georgios; Ilves, Kalle; Reigosa, Paula Diaz

    2016-01-01

    A new MATLAB/Simulink-based modeling platform has been developed for SiC MOSFET power modules. The modeling platform describes the electrical behavior f a single 1.2 kV/ 350 A SiC MOSFET power module, as well as the series connection of two of them. A fast parameter initialization is followed...... by an optimization process to facilitate the extraction of the model’s parameters in a more automated way relying on a small number of experimental waveforms. Through extensive experimental work, it is shown that the model accurately predicts both static and dynamic performances. The series connection of two Si......C power modules has been investigated through the validation of the static and dynamic conditions. Thanks to the developed model, a better understanding of the challenges introduced by uneven voltage balance sharing among series connected devices is possible....

  1. A pleural vacuum relief device for pleural drain unit use in the hyperbaric environment.

    Science.gov (United States)

    Gelsomino, Marco; Tsouras, Theo; Millar, Ian; Fock, Andrew

    2017-09-01

    When a standard water-seal pleural drain unit (PDU) is used under hyperbaric conditions there are scenarios where excessive negative intrapleural pressure (IPP) and/or fluid reflux can be induced, risking significant morbidity. We developed and tested a pleural vacuum relief (PVR) device which automatically manages these risks, whilst allowing more rapid hyperbaric pressure change rates. The custom-made PVR device consists of a one-way pressure relief valve connected in line with a sterile micro filter selected for its specific flow capacity. The PVR device is designed for connection to the patient side sampling port of a PDU system, allowing inflow of ambient air whenever negative pressure is present, creating a small, controlled air leak which prevents excessive negative pressure. The hyperbaric performance of a Pleur-Evac A-6000 intercostal drain was assessed with and without this added device by measuring simulated IPP with an electronic pressure monitor connected at the patient end of the PDU. IPP readings were taken at 10, 15, 20 and 30 cmH₂O of suction (set on the drain unit) at compression rates of 10, 30, 60, 80, 90 and 180 kPa·min⁻¹ to a pressure of 280 kPa. At any compression rate of > 10 kPa·min⁻¹, the negative IPP generated by the Pleur-Evac A-6000 alone was excessive and resulted in back flow through the PDU water seal. By adding the PVR device, the generated negative IPP remains within a clinically acceptable range, allowing compression rates of at least 30 kPa·min⁻¹ with suction settings up to -20 cmH₂O during all phases of hyperbaric treatment. The PDU PVR device we have developed works well, minimising attendant workload and automatically avoiding the excessive negative IPPs that can otherwise occur. This device should only be used with suction.

  2. Factors associated with sterilization use among women leaving a U.S. jail: a mixed methods study.

    Science.gov (United States)

    Ramaswamy, Megha; Kelly, Patricia J

    2014-07-31

    Despite the high rates of reported sterilization use among women who have spent time in correctional facilities, little is known about the context in which women in this population choose this option. The objective of our study was to use both quantitative and qualitative methods to understand factors associated with sterilization use among women leaving a U.S. jail. We administered a cross-sectional survey with 102 jailed women who were participating in a study about contraceptive use after release from jail, and then conducted semi-structured interviews with 29 of those women after their release from jail. We used logistic regression and analytic induction to assess factors associated with self-reported sterilization use. In our cross-sectional survey, one-third of our sample reported a history of sterilization use. Controlling for age and past pregnancies, the only factor associated with sterilization use was physical abuse history before age 16. In semi-structured interviews, we found that women's primary motivation for sterilization was the desire to limit childbearing permanently, in some cases where other contraceptive methods had failed them. The decision for sterilization was generally supported by family, partners, and providers. Many women who opted for sterilization expressed financial concern about supporting children and/or reported family histories of sterilization. The decision to use the permanent method of sterilization as a contraceptive method is a complex one. Results from this study suggest that while explicit coercion may not be a factor in women's choice for sterilization, interpersonal relationship histories, negative experiences with contraceptives, and structural constraints, such as financial concerns and ongoing criminal justice involvement, seem to influence sterilization use among the vulnerable group of women with criminal justice histories. Public health programs that connect women to reproductive health services should acknowledge

  3. High Speed Water Sterilization Using One-Dimensional Nanostructures

    KAUST Repository

    Schoen, David T.; Schoen, Alia P.; Hu, Liangbing; Kim, Han Sun; Heilshorn, Sarah C.; Cui, Yi

    2010-01-01

    The removal of bacteria and other organisms from water is an extremely important process, not only for drinking and sanitation but also industrially as biofouling is a commonplace and serious problem. We here present a textile based multiscale device for the high speed electrical sterilization of water using silver nanowires, carbon nanotubes, and cotton. This approach, which combines several materials spanning three very different length scales with simple dying based fabrication, makes a gravity fed device operating at 100000 L/(h m2) which can inactivate >98% of bacteria with only several seconds of total incubation time. This excellent performance is enabled by the use of an electrical mechanism rather than size exclusion, while the very high surface area of the device coupled with large electric field concentrations near the silver nanowire tips allows for effective bacterial inactivation. © 2010 American Chemical Society.

  4. High Speed Water Sterilization Using One-Dimensional Nanostructures

    KAUST Repository

    Schoen, David T.

    2010-09-08

    The removal of bacteria and other organisms from water is an extremely important process, not only for drinking and sanitation but also industrially as biofouling is a commonplace and serious problem. We here present a textile based multiscale device for the high speed electrical sterilization of water using silver nanowires, carbon nanotubes, and cotton. This approach, which combines several materials spanning three very different length scales with simple dying based fabrication, makes a gravity fed device operating at 100000 L/(h m2) which can inactivate >98% of bacteria with only several seconds of total incubation time. This excellent performance is enabled by the use of an electrical mechanism rather than size exclusion, while the very high surface area of the device coupled with large electric field concentrations near the silver nanowire tips allows for effective bacterial inactivation. © 2010 American Chemical Society.

  5. Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.

    Science.gov (United States)

    Mann, A; Kiefer, M; Leuenberger, H

    2001-03-01

    High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions.

  6. Nuclear reactor incorporating locking device for threaded bolt connections

    International Nuclear Information System (INIS)

    Blaushild, R.M.

    1987-01-01

    A nuclear reactor having a pressure vessel and a first element is described comprising a core barrel situated within the pressure vessel. The core barrel has a baffle former secured in and to the core barrel by bolted connections, and a second element comprising baffle plates secured to the inner surface of the baffle former by bolted connections, with a locking device to prevent loosening of bolted connections between the baffle former and at least one of the elements. The baffle former and at least one element are held together by a headed, threaded bolt engaged in a bore coaxially extending in the baffle former and at least one element and threadedly engaged in a threaded section in at least the baffle former. The threaded section has first threaded of a first direction, with the head of the bolt engaged with a shoulder about the bore in at least one element to hold the baffle formed and at least one element together, the head of the bolt having a first diameter and a cavity, having an unsymmetrical wall thereabout, in the end surface thereof. It comprises a recess in at least one element coaxial with the bore forming a wall thereabout and extending inwardly from the outer surface of at least one element, the recess having a second diameter greater than the first diameter, with at least one element having second threads in the wall of a direction opposite the direction of the first threads of the threaded bore; a locking nut having a base with a downwardly depending cylindrical wall thereabout

  7. Sterilization in Finland: from eugenics to contraception.

    Science.gov (United States)

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  8. Sterilization of space hardware.

    Science.gov (United States)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  9. Regret following female sterilization in Slovenia.

    Science.gov (United States)

    Becner, Anja; Turkanović, Anela Bečić; But, Igor

    2015-07-01

    To estimate the regret rate and risk factors for regret among women who have undergone sterilization. A retrospective study was conducted among all women who underwent a sterilization procedure at the University Medical Center Maribor, Maribor, Slovenia, in 2008-2012. Identified women were contacted and asked to complete an online questionnaire assessing regret and symptoms associated with depression. Among 714 identified women, 308 (43.1%) completed the questionnaire. Four (1.3%) participants reported regret, and 9 (2.9%) reported that they would not opt for sterilization again, all of whom had post-sterilization problems. Such problems were significantly associated with participants reporting that they would not opt for sterilization again (P=0.003). Additionally, women who would not choose sterilization again had significantly higher scores on the depressive scale used than did those who would undergo sterilization again (P=0.028). Few women report regret after tubal sterilization in Slovenia. However, an additional consultation on post-sterilization problems and depressive disorder before sterilization might minimize the risk of regret. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  10. Production of a sterile species via active-sterile mixing: An exactly solvable model

    Science.gov (United States)

    Boyanovsky, D.

    2007-11-01

    The production of a sterile species via active-sterile mixing in a thermal medium is studied in an exactly solvable model. The exact time evolution of the sterile distribution function is determined by the dispersion relations and damping rates Γ1,2 for the quasiparticle modes. These depend on γ˜=Γaa/2ΔE, with Γaa the interaction rate of the active species in absence of mixing and ΔE the oscillation frequency in the medium without damping. γ˜≪1, γ˜≫1 describe the weak and strong damping limits, respectively. For γ˜≪1, Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where θm is the mixing angle in the medium and the sterile distribution function does not obey a simple rate equation. For γ˜≫1, Γ1=Γaa and Γ2=Γaasin⁡22θm/4γ˜2, is the sterile production rate. In this regime sterile production is suppressed and the oscillation frequency vanishes at an Mikheyev-Smirnov-Wolfenstein (MSW) resonance, with a breakdown of adiabaticity. These are consequences of quantum Zeno suppression. For active neutrinos with standard model interactions the strong damping limit is only available near an MSW resonance if sin⁡2θ≪αw with θ the vacuum mixing angle. The full set of quantum kinetic equations for sterile production for arbitrary γ˜ are obtained from the quantum master equation. Cosmological resonant sterile neutrino production is quantum Zeno suppressed relieving potential uncertainties associated with the QCD phase transition.

  11. Cost-effectiveness analysis comparing the essure tubal sterilization procedure and laparoscopic tubal sterilization.

    Science.gov (United States)

    Thiel, John A; Carson, George D

    2008-07-01

    To analyze the financial implications of establishing a hysteroscopic sterilization program using the Essure micro-insert tubal sterilization system in an ambulatory clinic. A retrospective cohort study (Canadian Task Force classification Type II-2), in an ambulatory women's health clinic in a tertiary hospital, of 108 women undergoing Essure coil insertion between 2005 and 2006, and 104 women undergoing laparoscopic tubal sterilization for permanent sterilization between 2001 and 2004. The Essure procedures used a 4 mm single channel operative hysteroscope and conscious sedation (fentanyl and midazolam); the laparoscopic tubal sterilizations were completed under general anaesthesia with a 7 mm laparoscope and either bipolar cautery or Filshie clips. Costs associated with the procedure, follow-up, and management of any complications (including nursing, hospital charges, equipment, and disposables) were tabulated. The Essure coils were successfully placed on the first attempt in 103 of 108 women (95%). Three patients required a second attempt to complete placement and two patients required laparoscopic tubal sterilization after an unsuccessful Essure. All 104 laparoscopic tubals were completed on the first attempt with no complications reported. The total cost for the 108 Essure procedures, including follow-up evaluation, was $138,996 or $1287 per case. The total cost associated with the 104 laparoscopic tubal sterilization procedures was $148,227 or $1398 per case. The incremental cost-effectiveness ratio was $111. The Essure procedure in an ambulatory setting resulted in a statistically significant cost saving of $111 per sterilization procedure. Carrying out the Essure procedure in an ambulatory setting frees space in the operating room for other types of cases, improving access to care for more patients.

  12. 76 FR 13661 - In the Matter of Certain Connecting Devices (“Quick Clamps”) for Use With Modular Compressed Air...

    Science.gov (United States)

    2011-03-14

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-587] In the Matter of Certain Connecting Devices (``Quick Clamps'') for Use With Modular Compressed Air Conditioning Units, Including Filters... within the United States after importation of certain devices for modular compressed air conditioning...

  13. Predistortion control device and method, assembly including a predistortion control device

    NARCIS (Netherlands)

    Kokkeler, Andre B.J.

    2003-01-01

    A predistortion control device (1). The device has a first predistortion control input connectable to a power amplifier output (21); a second predistortion control input (11) connectable to a signal contact of a predistortion device; and a predistortion control output (12) connectable to a control

  14. Comparison of steam sterilization conditions efficiency in the treatment of Infectious Health Care Waste.

    Science.gov (United States)

    Maamari, Olivia; Mouaffak, Lara; Kamel, Ramza; Brandam, Cedric; Lteif, Roger; Salameh, Dominique

    2016-03-01

    Many studies show that the treatment of Infectious Health Care Waste (IHCW) in steam sterilization devices at usual operating standards does not allow for proper treatment of Infectious Health Care Waste (IHCW). Including a grinding component before sterilization allows better waste sterilization, but any hard metal object in the waste can damage the shredder. The first objective of the study is to verify that efficient IHCW treatment can occur at standard operating parameters defined by the contact time-temperature couple in steam treatment systems without a pre-mixing/fragmenting or pre-shredding step. The second objective is to establish scientifically whether the standard operation conditions for a steam treatment system including a step of pre-mixing/fragmenting were sufficient to destroy the bacterial spores in IHCW known to be the most difficult to treat. Results show that for efficient sterilization of dialysis cartridges in a pilot 60L steam treatment system, the process would require more than 20 min at 144°C without a pre-mixing/fragmenting step. In a 720L steam treatment system including pre-mixing/fragmenting paddles, only 10 min at 144°C are required to sterilize IHCW proved to be sterilization challenges such as dialysis cartridges and diapers in normal conditions of rolling. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Exploring factors in the decision to choose sterilization vs alternatives in rural El Salvador.

    Science.gov (United States)

    Cremer, Miriam L; Holland, Erica; Monterroza, Maritza; Duran, Sonia; Singh, Rameet; Terbell, Heather; Edelman, Alison

    2008-01-01

    To explore the factors that influence rural Salvadoran women to undergo tubal sterilization versus opting for alternative methods of family planning. A moderator fluent in English and Spanish conducted eleven 90-minute focus groups consisting of 5-10 women each. Eligible women in the municipality of San Pedro Perulapan, El Salvador, were identified and recruited by local health workers. Participant demographics and information about family planning decisions were collected through detailed notes and tape-recorded sessions. The tapes were transcribed verbatim, and all data were analyzed using grounded theory procedures to identify common themes. Eighty women aged 24-45 years who had previously been sterilized participated in the study. Three major themes influenced a woman's decision to undergo sterilization instead of opting for alternative forms of family planning: (1) availability: tubal sterilization is readily available, (2) fears about side effects of other methods: these women associated negative side effects with other forms of family planning, (3) effectiveness: the women in these focus groups thought sterilization was more effective than other forms of family planning. This study shows that there is a lack of information, and misinformation, about other effective methods of contraception, especially the intrauterine device and oral contraceptives. Reproductive health education projects, especially those providing services in locations similar to rural El Salvador, should focus on providing accurate information about all forms of contraception, including tubal sterilization.

  16. Multi-Device to Multi-Device (MD2MD Content-Centric Networking Based on Multi-RAT Device

    Directory of Open Access Journals (Sweden)

    Cheolhoon Kim

    2017-11-01

    Full Text Available This paper proposes a method whereby a device can transmit and receive information using a beacon, and also describes application scenarios for the proposed method. In a multi-device to multi-device (MD2MD content-centric networking (CCN environment, the main issue involves searching for and connecting to nearby devices. However, if a device can’t find another device that satisfies its requirements, the connection is delayed due to the repetition of processes. It is possible to rapidly connect to a device without repetition through the selection of the optimal device using the proposed method. Consequently, the proposed method and scenarios are advantageous in that they enable efficient content identification and delivery in a content-centric Internet of Things (IoT environment, in which multiple mobile devices coexist.

  17. Risk assessment of medical devices: evaluation of microbiological and toxicological safety

    International Nuclear Information System (INIS)

    Dorpema, J.W.

    1995-01-01

    Safety assessment of medical devices includes sterilization and biological evaluation or biocompatability testing. Sterilization by ETO gas is criticised for their carcinogenic potency or even banned. Mutual acceptance of biological evaluation test results is promoted by a laboratory accreditation and qualification program. (Author)

  18. Sterilizing insects with ionizing radiation

    International Nuclear Information System (INIS)

    Bakri, A.; Mehta, K.; Lance, D.R.

    2005-01-01

    Exposure to ionizing radiation is currently the method of choice for rendering insects reproductively sterile for area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Gamma radiation from isotopic sources (cobalt-60 or caesium-137) is most often used, but high-energy electrons and X-rays are other practical options. Insect irradiation is safe and reliable when established safety and quality-assurance guidelines are followed. The key processing parameter is absorbed dose, which must be tightly controlled to ensure that treated insects are sufficiently sterile in their reproductive cells and yet able to compete for mates with wild insects. To that end, accurate dosimetry (measurement of absorbed dose) is critical. Irradiation data generated since the 1950s, covering over 300 arthropod species, indicate that the dose needed for sterilization of arthropods varies from less than 5 Gy for blaberid cockroaches to 300 Gy or more for some arctiid and pyralid moths. Factors such as oxygen level, and insect age and stage during irradiation, and many others, influence both the absorbed dose required for sterilization and the viability of irradiated insects. Consideration of these factors in the design of irradiation protocols can help to find a balance between the sterility and competitiveness of insects produced for programmes that release sterile insects. Many programmes apply 'precautionary' radiation doses to increase the security margin of sterilization, but this overdosing often lowers competitiveness to the point where the overall induced sterility in the wild population is reduced significantly. (author)

  19. Eugenics and Involuntary Sterilization: 1907-2015.

    Science.gov (United States)

    Reilly, Philip R

    2015-01-01

    In England during the late nineteenth century, intellectuals, especially Francis Galton, called for a variety of eugenic policies aimed at ensuring the health of the human species. In the United States, members of the Progressive movement embraced eugenic ideas, especially immigration restriction and sterilization. Indiana enacted the first eugenic sterilization law in 1907, and the US Supreme Court upheld such laws in 1927. State programs targeted institutionalized, mentally disabled women. Beginning in the late 1930s, proponents rationalized involuntary sterilization as protecting vulnerable women from unwanted pregnancy. By World War II, programs in the United States had sterilized approximately 60,000 persons. After the horrific revelations concerning Nazi eugenics (German Hereditary Health Courts approved at least 400,000 sterilization operations in less than a decade), eugenic sterilization programs in the United States declined rapidly. Simplistic eugenic thinking has faded, but coerced sterilization remains widespread, especially in China and India. In many parts of the world, involuntary sterilization is still intermittently used against minority groups.

  20. Current status and future prospect of electron beam sterilization in Japan

    International Nuclear Information System (INIS)

    Katsura, Ichiro

    1998-01-01

    It seems that electron beam sterilization is being current topic among all applications in Japan and that this tendency will continue until when major companies interested in the technology complete introducing electron beam. Since the Ministry of Health and Welfare(MOHW) officially issued revised regulation on GMP for medical devices in 1995, EtO has become the method regarded as time and money consuming one. On the contrary, electron beam has become as relatively economical and desirable method to achieve same result by its characteristics such as high productivity, rather easy validation and consequent cost reduction, although less penetration limit the kind of products to be treated. Status and prospect of electron beam sterilization in Japan will be presented in the paper along with accelerator related technologies

  1. The smart aerial release machine, a universal system for applying the sterile insect technique: Manuscript Draft

    International Nuclear Information System (INIS)

    Mubarqui, Leal Ruben; Perez, Rene Cano; Klad, Roberto Angulo; Lopez, Jose L. Zavale; Parker, Andrew; Seck, Momar Talla; Sall, Baba; Bouyer, Jeremy

    2014-01-01

    Beyond insecticides, alternative methods to control insect pests for agriculture and vectors of diseases are needed. Management strategies involving the mass-release of living control agents have been developed, including genetic control with sterile insects and biological control with parasitoids, for which aerial release of insects is often required. Aerial release in genetic control programmes often involves the use of chilled sterile insects, which can improve dispersal, survival and competitiveness of sterile males. Currently available means of aerially releasing chilled fruit flies are however insufficiently precise to ensure homogeneous distribution at low release rates and no device is available for tsetse. Here we present the smart aerial release machine, a new design by the Mubarqui Company, based on the use of vibrating conveyors. The machine is controlled through Bluetooth by a tablet with Android Operating System including a completely automatic guidance and navigation system (MaxNav software). The tablet is also connected to an online relational database facilitating the preparation of flight schedules and automatic storage of flight reports. The new machine was compared with a conveyor release machine in Mexico using two fruit flies species (Anastrepha ludens and Ceratitis capitata) and we obtained better dispersal homogeneity (% of positive traps, p < 0.001) for both species and better recapture rates for Anastrepha ludens (p < 0.001), especially at low release densities (<1500 per ha). We also demonstrated that the machine can replace paper boxes for aerial release of tsetse in Senegal.This technology limits damages to insects and allows a large range of release rates from 10 flies/km"2 for tsetse flies up to 600 000 flies/km"2 for fruit flies. The potential of this machine to release other species like mosquitoes is discussed. Plans and operating of the machine are provided to allow its use worldwide.

  2. Comparison of two systems for rigidly connecting 2.0-mm bone screws to an implantable device : in vitro stability testing

    NARCIS (Netherlands)

    van Loon, JP; de Bont, LGM; Verkerke, GJ

    The stability of a screw-fixed implantable device can be improved by eliminating the freedom of movement between the screws and the device. Two systems have been developed for rigidly connecting 2.0-mm bone screws to an implantable device, and the aim of this study was to test and compare the

  3. Contraceptive behavior of couples undergoing sterilization in an Eastern State of India

    Directory of Open Access Journals (Sweden)

    Venkatarao Epari

    2017-01-01

    Full Text Available Background: As a part of a larger study for evaluating the effectiveness of a community-based family welfare program, this study assessed the contraceptive behavior of couples preceding sterilization and termination of pregnancies, if any during the interim period. Methods: During May–June 2013, a cross-sectional study was undertaken in three districts of Odisha, an eastern state of India with poor maternal health indicators. Using a 15 × 14 cluster design with probability proportionate to size sampling 15 village clusters from each district were selected. Seven beneficiaries from the catchment area of two Accredited Social Health Activist of the selected villages were interviewed (14 respondents from each village using a pretested predesigned questionnaire. Results: A total of 630 clients with either of the partner having undergone sterilization were interviewed. Male partner having undergone vasectomy was < 1% (n = 3. The mean age (standard error mean [SEM] of the respondent women was 34.54 ± 0.26 years. The mean age of the women at the time of sterilization was 27.12 (standard deviation [SD], 3.8, SEM 0.15 and median 26.83 years years. Women as young as 22 years had undergone sterilization. Average family size was 2.81 with about 29 respondents (4.5% having 5 or more children. The average duration between the last childbirth (LCB to the date of sterilization was 18.37 months (range: 1–142 months, SD: 24 months, SE: 10 months. Seventy-two percent of the respondents did not use any method of contraception during this period. Methods adopted for contraception among the users was pill (20% followed by condom (7%, and intrauterine contraceptive device (IUCD was least used (0.2%. Ten percent of the women had undergone abortion before sterilization either once (7.9% or more than once (2.1%. Conclusion: There was a gross delay in sterilization after LCB. Postpartum sterilization or IUCD were also not used frequently.

  4. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    International Nuclear Information System (INIS)

    Parker, A.; Mehta, K.

    2007-01-01

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discuss optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [es

  5. Pain Associated With Hysteroscopic Sterilization

    Science.gov (United States)

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  6. Women plan condom use after sterilization.

    Science.gov (United States)

    1998-12-01

    Sexual sterilization is highly effective in preventing pregnancy, but it does not protect against sexually transmitted diseases (STDs). People who accept sterilization as their method of family planning therefore need to be encouraged to protect themselves against HIV/AIDS and STDs even after they have been sterilized. Since women return less often to family planning providers following their sterilization procedure, they need to be advised to protect themselves against HIV and STDs before the sterilization is performed. 42% of the 2782 women who underwent tubal sterilizations at the Baylor College of Medicine in Houston during 1991-96 indicated their intention in a cross-sectional study to use condoms after sterilization. 20% of all respondents, aged 18-51 years, had a known risk factor for HIV, and almost 25% reported regular condom use for contraception or disease protection during the 3 months before sterilization. Planned condom use increased from 32% in 1991 to 51% in 1996, irrespective of age, marital status, or ethnic background. Of the 646 women who used condoms before being sterilized, almost half indicated no plans to do so after the procedure. The following factors were associated with condom use: relatively younger age, black ethnicity, unmarried status, history of previous STD, no steady partner, having a higher number of previous sex partners, past use of condoms to prevent disease transmission, and lack of partner involvement in the decision to undergo sterilization.

  7. Sterilization by gamma irradiation

    International Nuclear Information System (INIS)

    Reyes Frias, L.

    1992-01-01

    Since 1980 the National Institute of Nuclear Research counts with an Industrial Gamma Irradiator, for the sterilization of raw materials and finished products. Through several means has been promoted the use of this technology as alternative to conventional methods of sterilization as well as steam treatment and ethylene oxide. As a result of the made promotion this irradiator has come to its saturation limit being the sterilization irradiation one of the main services that National Institute of Nuclear Research offers to producer enterprises of disposable materials of medical use also of raw materials for the elaboration of cosmetic products and pharmaceuticals as well as dehydrated foods. It is presented the trend to the sterilization service by irradiation showed by the compilation data in a survey made by potential customers. (Author)

  8. Sterilization and reprocessing of materials and medical devices--reusability.

    Science.gov (United States)

    Jayabalan, M

    1995-07-01

    Problems associated with reprocessing of disposable medical devices such as hemodialysers with resterilization for reuse and changes in material properties with resterilization of polymeric (PVC, polypropylene, polyester, polycarbonate) materials intended for development of disposable devices are reviewed. Reprocessing of hospital supplies, polystyrene microtiter plate and angiographic catheter for reuse is also discussed.

  9. Male gametophytic sterility. 1 - Gametic sterilities and deletions in petunia

    Energy Technology Data Exchange (ETDEWEB)

    Cornu, A.; Maizonnier, D. (Station d' Amelioration des Plantes de l' I.N.R.A., Dijon (France))

    1982-01-01

    Terminal deletions induced by ionizing radiations in Petunia are not sexually transmitted. Cytogenetic study of plants with a heterozygous deletion and their progenies shows that this lack of transmission is accompanied by a gametic semi-sterility due to the fact that gametes carrying the deleted chromosome are not viable. The interest of such a male sterility with a gametophytic determinism for the study of sporophyte-gametophyte relationships is underlined.

  10. Health Care: Reprocessed Medical Single-Use Devices in DoD

    National Research Council Canada - National Science Library

    2002-01-01

    ... for decontamination and resterilization. The emergence of new materials and sterilization methods, and the increasing costs of health care, resulted in the development of medical single-use devices and the practice of reprocessing the devices...

  11. Sharing data between mobile devices, connected vehicles, and infrastructure task 3: system requirements specifications (SyRS) final.

    Science.gov (United States)

    2016-07-14

    This report describes the system requirements specifications (SyRS) for the use of mobile devices in a connected vehicle environment. Specifically, it defines the different types of requirements (functional, interface, performance, security, data, an...

  12. Lack of insurance and parity influence choice between long-acting reversible contraception and sterilization in women postpregnancy.

    Science.gov (United States)

    Baldwin, Maureen K; Rodriguez, Maria I; Edelman, Alison B

    2012-07-01

    Disparities in postpregnancy contraception utilization exist, with low-income women disproportionately undergoing sterilization. We assessed the impact of increased intrauterine device (IUD) availability on rates of female sterilization. Hospital billing records were used to identify women with an IUD placement or sterilization within 1 year of a pregnancy at a university hospital between Oct 2005 and Jun 2007. Demographic data were compared between women receiving either an IUD or sterilization. There were 365 sterilizations and 223 IUD placements during the study period. IUD placements doubled over the study period from 6% to 12% of all deliveries, while sterilizations remained stable at 11% (pwomen with either public or private insurance who had financial access to both sterilization (n=253) and IUD (n=223). Women receiving sterilization were slightly older (mean age 31 years versus 30 years, p=.03), of higher parity (median three versus two, pwomen who received IUD. Approximately 45% of women delivering in Oregon in 2007 were publicly insured (2010 Maternal and Child Health Update: States Make Progress Towards Improving Systems of Care. National Governor's Association, Table 6. Available at http://www.nga.org/files/live/sites/NGA/files/pdf/MCHUPDATE2010.PDF, accessed Nov 2011). After adjusting for age, parity and type of delivery, women choosing sterilization were more likely to have public insurance than women choosing IUD (odds ratio 8.4, 95% confidence interval 4.7-14.9, pWomen choosing sterilization are more likely to have public insurance than women choosing IUD and may represent a continued trend toward nonreversible contraception among women of lower socioeconomic status despite available long-acting reversible methods. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice.

    Science.gov (United States)

    El-Namaky, R; van Oort, P A J

    2017-12-01

    There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two EGMS lines tested here, it was not clear if one or more recessive gene(s) were causing male sterility. This was tested by studying sterility segregation of the F2 populations. Daylength (photoperiod) and minimum temperatures during the period from panicle initiation to flowering had significant effects on male sterility. Results clearly showed that only one recessive gene was involved in causing male sterility. The model was applied to determine the set of sowing dates of two different EGMS lines such that both would flower at the same time the pollen would be completely sterile. In the same time the local popular variety (Sahel 108, the male pollen donor) being sufficiently fertile to produce the hybrid seeds. The model was applied to investigate the viability of the two line breeding system in the same location with climate change (+2oC) and in two other potential locations: in M'Be in Ivory Coast and in the Nile delta in Egypt. Apart from giving new insights in the relation between environment and EGMS, this study shows that these insights can be used to assess safe sowing windows and assess the suitability of sterility and fertility period of different environments for a two line hybrid rice production system.

  14. Materials Surfaces and sterility

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R.

    2001-04-01

    A question of great interest in sterile and clean room technology is how can we devise a standard for the guarantee of sterility? Sterility is of widespread importance: it gives the life-time of our daily milk or yogurt, dominates the nature of food packing, and determines the feasibility of the miniaturization of biotechnology plants. All these phenomena are based on the principle of bioadhesion. Bioadhesion is also the basis of the biomimetic material technologies, like the attachment of selected protein layers that can be used for nanomasking. (orig.)

  15. Challenges to validation of a complex nonsterile medical device tray.

    Science.gov (United States)

    Prince, Daniel; Mastej, Jozef; Hoverman, Isabel; Chatterjee, Raja; Easton, Diana; Behzad, Daniela

    2014-01-01

    Validation by steam sterilization of reusable medical devices requires careful attention to many parameters that directly influence whether or not complete sterilization occurs. Complex implant/instrument tray systems have a variety of configurations and components. Geobacillus stearothermophilus biological indicators (BIs) are used in overkill cycles to to simulate worst case conditions and are intended to provide substantial sterilization assurance. Survival of G. stearothermophilus spores was linked to steam access and size of load in the chamber. By a small and reproducible margin, it was determined that placement of the trays in a rigid container into minimally loaded chambers were more difficult to completely sterilize than maximally loaded chambers.

  16. Thermalizing Sterile Neutrino Dark Matter.

    Science.gov (United States)

    Hansen, Rasmus S L; Vogl, Stefan

    2017-12-22

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  17. Thermalizing Sterile Neutrino Dark Matter

    Science.gov (United States)

    Hansen, Rasmus S. L.; Vogl, Stefan

    2017-12-01

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  18. Sharing data between mobile devices, connected vehicles and infrastructure - task 3: concept of operations : technical memorandum -final.

    Science.gov (United States)

    2016-07-13

    This report describes the concept of operation for the use of mobile devices in a connected vehicle environment. Specifically, it identifies the needs, conceptual system, and potential scenarios that serve as the basis for demonstrating both safety a...

  19. Sterile Endophthalmitis after Intravitreal Injections

    Directory of Open Access Journals (Sweden)

    Joaquín Marticorena

    2012-01-01

    Full Text Available Sterile endophthalmitis appears as an infrequent complication of intravitreal injections and seems to develop mainly in the context of the off-label use of drugs that have not been conceived for intravitreous administration. The aetiology of sterile endophthalmitis, independently of the administered drug, remains uncertain and a multifactorial origin cannot be discarded. Sterile inflammation secondary both to intravitreal triamcinolone acetonide and to intravitreal bevacizumab share many characteristics such as the acute and painless vision loss present in the big majority of the cases. Dense vitreous opacity is a common factor, while anterior segment inflammation appears to be mild to moderate. In eyes with sterile endophthalmitis, visual acuity improves progressively as the intraocular inflammation reduces without any specific treatment. If by any chance the ophthalmologist is not convinced by the sterile origin of the inflammation, this complication must be treated as an acute endophthalmitis because of the devastating visual prognosis of this intraocular infection in the absence of therapy.

  20. 21 CFR 522.1862 - Sterile pralidoxime chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile pralidoxime chloride. 522.1862 Section 522....1862 Sterile pralidoxime chloride. (a) Chemical name. 2-Formyl-1-methylpyridinium chloride oxime. (b) Specifications. Sterile pralidoxime chloride is packaged in vials. Each vial contains 1 gram of sterile...

  1. Food packaging and radiation sterilization

    International Nuclear Information System (INIS)

    Kawamura, Yoko

    1998-01-01

    Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The γ ray and an electron beam are commonly used in radiation sterilization. The γ ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing relatively thin materials and surface sterilization due to the weak transmission. A typical sterilization dose is approximately 10-30 kGy. Direct effects impacting packaging materials, particularly plastics, include scission of polymer links, cross-linkage between polymers, and generating radiolysis products such as hydrogen, methane, aliphatic hydrocarbons, etc. Furthermore, under the existence of oxygen, the oxygen radicals generated by the radiation will oxidize and peroxidize polymer chains and will generate alcohol and carbonyl groups, which shear polymer links, and generate oxygen containing low molecular compounds. As a result, degradation of physical strength such as elongation and seal strength, generating foreign odor, and an increase in global migration values shown in an elution test are sometimes evident. The food packages have different shapes, materials, additives, number of microorganisms and purpose. Therefor the effects of radiation, the optimum dose and so on must be investigated on the individual package. (J.P.N.)

  2. Seeking sterile neutrinos in Finslerian cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Deng [Nankai University, Theoretical Physics Division, Chern Institute of Mathematics, Tianjin (China); Meng, Xin-He [Nankai University, Department of Physics, Tianjin (China)

    2017-11-15

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H{sub 0} tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N{sub eff} = 3.237{sup +0.092}{sub -0.185}, which is consistent with ΔN{sub eff} > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N{sub eff} = 3.143{sup +0.064}{sub -0.066}, which favors ΔN{sub eff} > 0 at the 1.47σ CL, and m{sub ν,sterile}{sup eff} < 0.121 eV at the 2σ CL which is much tighter than the Planck results. This very tight restriction appears to indicate the massive sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration. (orig.)

  3. Documentation requirements for radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation for appr......Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation...... for approval of radiation sterilized products. The impact of these standards on the radiation sterilization is discussed, with special attention given to a few special issues, mainly traceability and uncertainty of measurement results....

  4. Plasma Sterilization: New Epoch in Medical Textiles

    Science.gov (United States)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  5. Sterilization can change properties of bioceramics

    International Nuclear Information System (INIS)

    Willmann, G.

    2003-01-01

    Bioceramics made of bioinert alumina or zirconia and bioactive hydroxyapatite are well established implant materials. Implants have to be cleaned and sterilized. When sterilized some bioceramics change their color. This may effect their properties. No decrease of mechanical strength is observed when sterilizing alumina and the novel ceramic biocomposite AMC (Alumina Matrix Composite) with steam or Co 60 Gamma irradiation. When sterilizing Y-TZP zirconia with steam a decrease of strength is observed. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [de

  6. Hysteroscopic Sterilization With Essure: Summary of the U.S. Food and Drug Administration Actions and Policy Implications for Postmarketing Surveillance.

    Science.gov (United States)

    Walter, Jessica R; Ghobadi, Comeron W; Hayman, Emily; Xu, Shuai

    2017-01-01

    In September 2015, the U.S. Food and Drug Administration (FDA) convened a meeting of the Obstetrics and Gynecology Advisory Board Committee to address the sudden increase of patient-reported adverse events surrounding Essure, a Class III device offering a less invasive method for permanent female sterilization. After a review of the premarketing and postmarketing data and existing scientific literature, the FDA concluded there was insufficient evidence to remove the device from the market. However, the FDA did release a new guidance document requiring a black box warning for the device and ordered a new postmarketing study comparing Essure's safety and efficacy with laparoscopic tubal sterilization. The device was first approved in 2002 based on nonrandomized, single-arm prospective clinical studies. Since its approval, the device has grown in popularity, particularly in the United States. The driving forces for the sudden increase in adverse event reporting starting in 2013 related to the device remain unclear. Until completion of the new postmarketing study, there will continue to be significant uncertainty of the technology's risk-benefit profile. The controversy with Essure underscores the need for obstetricians and gynecologists to be actively involved in the lifecycle of medical devices. This includes actively reporting adverse events associated with devices to the FDA, supporting the implementation of unique device identifiers enriched with clinical records and paired with insurance claims, and stewarding robust device-specific registries.

  7. Birth planning and sterilization in China.

    Science.gov (United States)

    Short, S E; Linmao, M; Wentao, Y

    2000-11-01

    Sterilization is the most prevalent method of contraception in China. Approximately half of all women of reproductive age report that they or their husbands are sterilized. Using data from the China Health and Nutrition Survey we describe patterns of sterilization in eight Chinese provinces. With a discrete-time event history model we investigate the link between characteristics of local birth planning policy and the risk of sterilization. After controlling for parity, the risk of sterilization is highest in communities where birth planning policy is least strong as measured by exceptions to the one-child policy. These results suggest that couples with more flexibility in family building may have less control over contraceptive method use. Other factors affecting the risk of sterilization are a woman's age, parity, and whether or not she has a son. Our results emphasize the importance of taking into account multiple dimensions of reproductive behaviour when assessing one-child policy changes.

  8. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene

    OpenAIRE

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-01-01

    Nuclear male sterility is common in flowering plants, but its application in hybrid breeding and seed production is limited because of the inability to propagate a pure male sterile line for commercial hybrid seed production. Here, we characterized a rice nuclear gene essential for sporophytic male fertility and constructed a male sterility system that can propagate the pure male sterile seeds on a large scale. This system is fundamentally advantageous over the current cytoplasmic male steril...

  9. Validation of radiation sterilization process

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    The standards for quality management systems recognize that, for certain processes used in manufacturing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product. Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of sterilization process is monitored routinely and the equipment is maintained according to ISO 13 485. Different aspects of this norm are presented

  10. The male gametophytic sterility. 1 - Gametic sterilities and deletions in petunia

    International Nuclear Information System (INIS)

    Cornu, A.; Maizonnier, D.

    1982-01-01

    Terminal deletions induced by ionizing radiations in Petunia are not sexually transmitted. Cytogenetic study of plants with a heterozygous deletion and their progenies shows that this lack of transmission is accompanied by a gametic semi-sterility due to the fact that gametes carrying the deleted chromosome are not viable. The interest of such a male sterility with a gametophytic determinism for the study of sporophyte-gametophyte relationships is underlined [fr

  11. Radiosterilization or sterilization by steam. Procedures for sterilization of spices

    International Nuclear Information System (INIS)

    Warmbold, J.

    1994-01-01

    The article compares two different methods for the sterilization of spices, namely radiosterilization and sterilization with steam. The first method applies ionizing radiation which can alter the chemical composition of the products. Tests have shown, however, that radiation doses up to 10 kGy will not induce the formation of carcinogenic agents in the foodstuffs, or of toxic substances, and thus are a wholesome method of preservation. Any modifications of taste, color or smell, or loss of vitamins, can be avoided by proper dose control and standard irradiation conditions. Sterilization by steam is a method achieving substantial suppression of the formation of germs, aerobic spores, yeasts, mould, and gramnegative germs, while preserving in most cases the essential oils. It may result in sensoric alterations, i.e affect the color, smell or taste, but in general the spices thus treated preserved their characteristic properties. The method is a good alternative to radiosterilization. The article adds some concluding information on mandatory labelling of irradiated food imported from third countries

  12. Efficacy of Essure hysteroscopic sterilization--5 years follow up of 1200 women.

    Science.gov (United States)

    Ríos-Castillo, José E; Velasco, Esther; Arjona-Berral, José E; Monserrat Jordán, José A; Povedano-Cañizares, Balbino; Castelo-Branco, Camil

    2013-06-01

    To assess the efficacy of the Essure hysteroscopic birth control device after 5 years follow up. Retrospective analysis of case series. Outpatient hysteroscopy facility in a large teaching hospital. One-thousand three-hundred and twenty-one women who underwent hysteroscopic sterilization with Essure device (Conceptus, Inc., Mountain View, CA) between January 2003 and May 2005. Hysteroscopic tubal sterilization using Essure system. Efficacy/effectiveness, failure rate. Satisfactory insertion was accomplished in the first attempt in 1166 women (97.16%). After the second attempt, successful insertion rate rise to 98.6%. (n = 31, 2.6%). Three pregnancies had been reported after 5 years follow up, which implies an overall absolute rate of 0.25%. This represents a Pearl index of 0.05 after 72,000 months of surveillance. All of them occurred in the first year of use of the microinsert. There has been no unintended pregnancy in the next 4 years. Essure has the lowest Pearl index never published being the most effective permanent birth control system to date. Unintended pregnancies tend to occur in the first year after the insertion, and can be avoided encouraging women to accomplish the protocol.

  13. [Legal statutes on sterilization].

    Science.gov (United States)

    Zupancic, K

    1980-01-01

    Sterilization in Yugoslavia is no population policy measure. Decision about the birth of children is free, a private problem of any individual, a basic right guaranteed by the Constitution. However, according to certain laws in Slovenia and Croatia, sterilization is allowed as a family planning method in persons over 35 year old. Only exceptionally can sterilization be applied in persons younger than 35 years: according to the Slovenian law, in cases when a person lacks the capacity of reasoning and also when there are medical indications, and according to the Croatian law, when there are medical and eugenic reasons (if the child is supposed to be born with negative congenital properties).

  14. NREL Topic 1 Final Report: Cohesive Application of Standards-Based Connected Devices to Enable Clean Energy Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Hudgins, Andrew P. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sparn, Bethany F. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jin, Xin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Seal, Brian [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States)

    2018-02-21

    This document is the final report of a two-year development, test, and demonstration project entitled 'Cohesive Application of Standards-Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL) Integrated Network Test-bed for Energy Grid Research and Technology (INTEGRATE) initiative. The Electric Power Research Institute (EPRI) and a team of partners were selected by NREL to carry out a project to develop and test how smart, connected consumer devices can act to enable the use of more clean energy technologies on the electric power grid. The project team includes a set of leading companies that produce key products in relation to achieving this vision: thermostats, water heaters, pool pumps, solar inverters, electric vehicle supply equipment, and battery storage systems. A key requirement of the project was open access at the device level - a feature seen as foundational to achieving a future of widespread distributed generation and storage. The internal intelligence, standard functionality and communication interfaces utilized in this project result in the ability to integrate devices at any level, to work collectively at the level of the home/business, microgrid, community, distribution circuit or other. Collectively, the set of products serve as a platform on which a wide range of control strategies may be developed and deployed.

  15. Genetic basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Robinson, A.S.

    2014-01-01

    The use of the sterile insect technique for insect control relies on the introduction of sterility in the females of the wild population. This sterility is produced following the mating of these females with released males carrying, in their sperm, dominant lethal mutations that have been induced by ionizing radiation. As well as radiation-induced sterility, natural mechanisms can be recruited, especially the use of hybrid sterility. Radiation is usually one of the last procedures that insects undergo before leaving mass-rearing facilities for release in the field. It is essential that the dosimetry of the radiation source be checked to ensure that all the insects receive the required minimum dose. A dose should be chosen that maximizes the level of introduced sterility in the wild females in the field. Irradiation in nitrogen can provide protection against the detrimental somatic effects of radiation. Currently, the development of molecular methods to sterilize pest insects in the field, by the release of fertile insects carrying trans genes, is very much in vogue. It is concluded that using a physical process, such as radiation, will always have significant advantages over genetic and other methods of sterilization for the large-scale application of the sterile insect technique. (author)

  16. Evaluation of composition of acai berry oil (Euterpe oleracea) submitted to sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Ana Carolina H.R.; Lugao, Ademar B.; Rogero, Sizue O.; Bustillos, Jose Oscar V.; Pires, Maria Aparecida F. [Instituto de Pesquisas Energeticas e Nucleares IPEN/CNEN-SP, Sao Paulo, SP (Brazil)]. E-mail: acmachado@ipen.br

    2007-07-01

    Acai berry (Euterpe oleracea) is a native palm of Brazil, distributed for the entire Amazonian basin. Rich in essentials fatty acids (mainly oleic acid and linoleic acid), the Acai oil prevents abnormal conditions of the skin, as dermatitis and drying, and assists in the regeneration of the epidermis. Therefore, it is proposed a more effective topical administration of the Acai oil by its immobilization in BandGel type hydrogels, which is crosslinked and sterilized by ionizing radiation. The objective of this work was to evaluate the composition of the oil when submitted to a sterilizing dose of ionizing radiation. The oil composition was determined by gas chromatography connected with mass spectrometry (GC-MS). The results showed a small decrease in the concentration of ester acids and increase of some main products, i.e., ethyl oleic and palmitic acids. (author)

  17. Evaluation of composition of acai berry oil (Euterpe oleracea) submitted to sterilization

    International Nuclear Information System (INIS)

    Machado, Ana Carolina H.R.; Lugao, Ademar B.; Rogero, Sizue O.; Bustillos, Jose Oscar V.; Pires, Maria Aparecida F.

    2007-01-01

    Acai berry (Euterpe oleracea) is a native palm of Brazil, distributed for the entire Amazonian basin. Rich in essentials fatty acids (mainly oleic acid and linoleic acid), the Acai oil prevents abnormal conditions of the skin, as dermatitis and drying, and assists in the regeneration of the epidermis. Therefore, it is proposed a more effective topical administration of the Acai oil by its immobilization in BandGel type hydrogels, which is crosslinked and sterilized by ionizing radiation. The objective of this work was to evaluate the composition of the oil when submitted to a sterilizing dose of ionizing radiation. The oil composition was determined by gas chromatography connected with mass spectrometry (GC-MS). The results showed a small decrease in the concentration of ester acids and increase of some main products, i.e., ethyl oleic and palmitic acids. (author)

  18. Electron sterilization validation techniques using the controlled depth of sterilization process

    International Nuclear Information System (INIS)

    Cleghorn, D.A.; Nablo, S.V.

    1990-01-01

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and X-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating X-ray dose ratios are possible for the application of the technique. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed. (author)

  19. [Assessment of decontamination processes: cleaning, disinfection and sterilization in dental practice in Poland in the years 2011-2012].

    Science.gov (United States)

    Röhm-Rodowald, Ewa; Jakimiak, Bozenna; Chojecka, Agnieszka; Zmuda-Baranowska, Magdalena; Kanclerski, Krzysztof

    2012-01-01

    Effective decontamination of instruments is a key element of infection control and the provision of high quality in dental care. The aim of the study was to evaluate the efficiency of decontamination procedures including cleaning, disinfection and sterilization of re-usable instruments in dental practices in Poland. The efficiency of disinfection and sterilization processes have been evaluated on the results of the questionnaires. The following information were taken into account: setting where disinfection and sterilization had been performed, preparation of dental equipment for sterilization (disinfection, washing and cleaning, packaging), the types of autoclaves and used types of sterilization cycles, routine monitoring and documentation of sterilization processes, treatment of handpieces and the frequency of surface decontamination. Data were collected from 43 dental practices (35 dental offices and 8 clinics). Disinfection and cleaning processes were performed manually in 63% of dental offices and ultrasonic baths were used in 53% of settings. Washer disinfectors were used in 23% of dental practices: in every researched clinic and in a few dental offices. All sterilization processes were performed in steam autoclaves, mainly in small steam sterilizers (81%). Dental handpieces were sterilized in 72% of practices, but only 33% of them performed sterilization in recommended cycle B. Sterilization processes were monitored with chemical indicators in 33% of practices. Biological monitoring of the processes was carried out at different intervals. Incorrect documentation of instruments and surfaces decontamination was recorded in several settings. There is still a need for improvement of decontamination processes in dental practice in Poland. Areas for improvement include: replacement of manual cleaning and disinfection processes with automatic processes, sterilization of dental handpieces after each patient, monitoring of a sterilization process with chemical and

  20. Male sterility in chestnuts

    International Nuclear Information System (INIS)

    Omura, Mitsuo; Akihama, Tomoya

    1982-01-01

    A tentative plan was proposed for chestnuts based on their pollination system, male sterility and restoration. The studies on the male sterility of 1,063 cultivars and clones suggested that there were three types of male sterility. The first type (S-1) was characterized by antherless florets. In the second type (S-2), the catkins fell before anthesis, and the third type (S-3) appeared to develop normally in gross floral morphology, but the pollen grains were abnormal in shape and did not have germinating power. In an interspecific hybrid clone CS which belonged to S-1, fertility was restored in an open pollinated progeny. The use of CS and CSO-3 with its restored fertility, permitted the planning of breeding the chestnut hybrid cultivars propagated by seeds. The inbred clones with either male sterility or restorer genes are first bred mainly by back crossing with parents with favorable pollen. The clones are selected individually for early bearing, wasp and disease resistance, and restoration. Then, the hybrid seedling lines between male sterile and restorer inbreds are evaluated for homogenity in nut characters and tree habits. Next, the hybrid seedling lines selected will be examined for crop yield, vigor and cross compatibility. The superior seedling lines are finally selected, and the parental inbreds are grafted to be propagated for seed production orchards. (Kaihara, S.)

  1. Gamma sterilization of disposable medical products (DMP's)

    International Nuclear Information System (INIS)

    Brinston, R.M.

    1990-01-01

    Ten million cubic meters (361 million cubic feet) of disposable medical products (DMP) and related health care items are estimated to be sterilized in the world. In this paper, current conditions and perspectives of gamma sterilization is discussed in comparison with ethylene oxide gas and electron beams. Of the total sterilization estimates for DMP, 2.8 million cubic meters (99 million cubic feet) are sterilized with gamma radiation, with a market share of 27%. Gamma radiation is becoming increased from both general market growth and the introduction of new products, as well as the conversion of product from ethylene oxide gas to cobalt-60. Regulatory pressures, legal considerations, and increasing publicity surrounding ethylene oxide usage are encouraging manufactures to switch to gamma radiation. Gamma's performance features include: no temperature change during the sterilization, high penetration, even through hermetically sealed packages, no residues, and no post-sterilization treatment or quarantine period. Gamma sterilization is economically beneficial in large volumes of product. Cost saving to the end user of gamma sterilization has meant lower minimum dose levels than 25 KGy. Despite of an increasingly accepted gamma radiation, there are still four factors to be considered, including cobalt-60 availability, price, transportation, and disposal. The price of cobalt-60 is based on neutron cost. In the future, cobalt-60 price is expected to be flat and enables gamma processing to become even more competitive with other sterilization methods. Gamma radiation using cobalt-60 has been proven as a safe, effective, and cost-competitive sterilization method for treating DMP and related health care items. It's wide use and many processing advantages will continue to make it a preferred sterilization method. (N.K.)

  2. Probabilistic model for sterilization of food

    International Nuclear Information System (INIS)

    Chepurko, V.V.; Malinovskij, O.V.

    1986-01-01

    The probabilistic model for radiation sterilization is proposed based on the followng suppositions: (1) initial contamination of a volume unit of the sterilized product m is described by the distribution of the probabilities q(m), (2) inactivation of the population from m of microorganisms is approximated by Bernoulli test scheme, and (3) contamination of unit of the sterilized product is independent. The possibility of approximation q(m) by Poisson distribution is demonstrated. The diagrams are presented permitting to evaluate the dose which provides the defined reliability of sterilization of food for chicken-gnotobionts

  3. Study of the effects of different sterilization methods on the properties of dense and porous silk fibroin membranes

    International Nuclear Information System (INIS)

    Weska, Raquel F.; Moraes, Mariana A. de; Beppu, Marisa M.

    2009-01-01

    Silk fibroin has been widely explored for many biomedical applications, due to its biocompatibility and biodegradability. Sterilization is a fundamental step in biomaterials processing, and it must not alter in a negative way the functionality of medical devices. The aim of this study was to analyze the influence of different sterilization methods in the physical and chemical characteristics of dense silk fibroin membranes. Dense fibroin membranes were sterilized by ultraviolet radiation, 70% ethanol, autoclave, ethylene oxide and gamma radiation, and were analyzed by SEM, FTIR-ATR and XRD. The results for sterilization indicated that the methods didn't cause degradation of the membranes, but the methods that used organic solvent, or increase of humidity and/or temperature (70% ethanol, autoclave and ethylene oxide) altered the molecular conformation of fibroin, increasing the proportion of β-sheet structure, what indicates an increase of crystallinity. This effect may be positive when a slower degradation of the membranes is desired, depending on the application as a bio material. (author)

  4. Voluntary sterilization in Serbia: Unmet need?

    Directory of Open Access Journals (Sweden)

    Rašević Mirjana M.

    2002-01-01

    Full Text Available Is voluntary sterilization as a birth control method accepted in Serbia? This is certainly a question that is being imposed for research, regardless of the fact that voluntary sterilization is neither accessible nor promoted. Most importantly because there is no understanding in the social nor political sphere for legalization of voluntary sterilization as a form of birth control, apart from the clear necessity for this, first, step. They are: the recognition that voluntary sterilization is an efficient and safe birth control method, respectability of basic human as well as sexual and reproductive rights, spreading of sterilization as a form of birth control among population of both developed and developing countries and an epidemic diffusion of repeated induced abortions in Serbia. Thus individual recognition of the advantages of relying on voluntary sterilization, in a non-encouraging atmosphere, certainly represents one more argument to enable couples to prevent conception by sterilization. Since it was impossible to carry out a representative research among the population of men and women who are at risk for conception, an attempt was made to obtain a reply to the set question among women who decided to induce abortion. It was done out of at least two reasons. The first being that women with induced abortion in their reproductive history were the target group for voluntary sterilization. The second reason was based on the assumption that bringing a decision on induced abortion is preceded by the reconsideration of an earlier adopted strategy regarding children, giving birth and contraception and thus its rational component is revealed more and therefore more easily measurable. The research was carried out in the University Clinic of Obstetrics and Gynecology 'Narodni front' in Belgrade from January 21st o March 1st 2002, and included 296 women. By comparing the social and demographic characteristics of the female respondents, as well as

  5. Forced sterilization of women as discrimination.

    Science.gov (United States)

    Patel, Priti

    2017-01-01

    There has been a long history of subjecting marginalized women to forced and coerced sterilization. In recent years, the practice has been documented in countries in North and South America, Europe, Asia, and Africa. It has targeted women who are ethnic and racial minorities, women with disabilities, women living with HIV, and poor women. A handful of courts have issued decisions on the recent forced sterilization of marginalized women finding that such actions violate the women's rights. However, they have all failed to address the women's claims of discrimination. The failure to acknowledge that forced sterilization is at its core a violation of the prohibition of discrimination undermines efforts to eradicate the practice. It further fails to recognize that coerced and forced sterilization fundamentally seeks to deny women deemed as "unworthy" the ability to procreate. Four key principles outlined in the human rights in patient care framework highlight the importance of a finding that the prohibition of discrimination was violated in cases of forced sterilization: the need to highlight the vulnerability of marginalized populations to discrimination in health care settings; the importance of the rights of medical providers; the role of the state in addressing systemic human rights violations in health care settings; and the application of human rights to patient care. Based on these principles, it is clear that finding a violation of the prohibition of discrimination in forced sterilization cases is critical in addressing the systemic nature of the practice, acknowledging the marginalization of specific groups and effectively ending forced sterilization through addressing the underlying purpose of the practice. If litigators, non-governmental organizations and judicial officers are mindful of these principles when dealing with cases of forced sterilization, it is likely that they will be better able to eradicate forced sterilization.

  6. Sterility induction in tsetse

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, C F [London School of Hygiene and Tropical Medicine (UK); Langley, P A [Bristol Univ. (UK)

    1982-01-01

    The first laboratory and field experiments on genetic control were with tsetse flies, and they made use of the sterility in crosses and hybrids between closely related species of the Glossina morsitans complex. Backcrosses indicate that there are two separate sterility mechanisms involved: (a) genetic incompatibility between a mother and the products of alien genes in the embryo or larva in the uterus; (b) inability of hybrid males to inseminate due to incompatibility of their X-chromosomes with an alien Y or autosomes. The two largest sterile male release programmes have been in Tanzania and Upper Volta, and have used irradiation at the pupal or adult stage, respectively, for the production of sterility. Male tsetse are remarkably resistant to radiosterilization and, with the doses required to induce dominant lethals in more than 95% of sperms, premature senescence and lethargic behaviour of the males tends to result. With G. morsitans irradiated at the puparial stage these effects can be alleviated by the use of a nitrogen atmosphere during irradiation. If the puparia are then transferred to air at 11/sup 0/C for transport to the release site, immediate emergence occurs on re-warming after arrival. This advantageous procedure was used for the releases in Tanzania. In addition to dominant lethals, irradiation also produces chromosome translocations which cause inherited partial sterility. A homozygous translocation line was selected but this example did not have sufficient fitness to be used in a mass rearing programme. Chemosterilants can be applied by pupal dipping, adult contact with deposits or in aerosols. Studies are now in progress on their use in association with odour-baited traps or pheromone-baited decoys as a means of sterilizing the wild population and thus avoiding the costly and difficult process of mass rearing tsetse.

  7. Connections for the Digital Age Multimedia Communications for Mobile, Nomadic and Fixed Devices

    CERN Document Server

    Carne, E Bryan

    2011-01-01

    Explores and analyzes past and current technologies and trends in multimedia communication Digital natives-those persons born in the digital age-have an ever-widening range of wireless-enabled devices at their disposal. They are the drivers of multimedia communications, continually seeking out the technologies and distribution channels that best match their needs. This book outlines the changes in telecommunications that are occurring to meet these needs. It addresses the continually increasing requirement to provide connections that make the electronic encounter as natural and convenient as p

  8. Sterile neutrino dark matter with supersymmetry

    Science.gov (United States)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  9. Genetic complexity underlying hybrid male sterility in Drosophila.

    Science.gov (United States)

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-02-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic basis of hybrid male sterility more complex than that of hybrid female sterility and inviability? To clarify this point, the D. simulans introgression of the cytological region 34D-36A to the D. melanogaster genome, which causes recessive male sterility, was dissected by recombination, deficiency, and complementation mapping. The 450-kb region between two genes, Suppressor of Hairless and snail, exhibited a strong effect on the sterility. Males are (semi-)sterile if this region of the introgression is made homozygous or hemizygous. But no genes in the region singly cause the sterility; this region has at least two genes, which in combination result in male sterility. Further, the males are less fertile when heterozygous with a larger introgression, which suggests that dominant modifiers enhance the effects of recessive genes of male sterility. Such an epistatic view, even in the less-related species, suggests that the genetic complexity is special to hybrid male sterility.

  10. Inheritance of sterility in Dysdercus koenigii F. (Hemiptera: Pyrrhocoridae)

    International Nuclear Information System (INIS)

    Harwalkar, M.R.; Rahalkar, G.W.

    1979-01-01

    It has been suggested that for the control of Lepidopterous populations, release of fully competitive partially sterile males would be more advantageous than the release of completely sterile males. This suggestion is based on the fact, elucidated in many studies, that partially sterilized males mated to normal females produce totally sterile or partially sterile progeny. In Hemiptera too, F 1 progeny of partially sterile males has been shown to inherit sterility. Individual impact of sterility inherited by either sex of the F 1 progeny on population growth has been studied in an hemipteran insect Dysdercus koenigii. A dose of 7 krad induces near-complete sterility in males. When males irradiated with substerilizing doses of 1,2 and 3 krad were crossed with normal females, F 1 progeny of both sexes was partially sterile : the female being more sterile than the males. When the F 1 progeny was intercrossed, there was enhanced reduction in progeny production. (auth.)

  11. Electrolytic silver ion cell sterilizes water supply

    Science.gov (United States)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  12. Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

    Science.gov (United States)

    Mora, Maria F.; Stockton, Amanda M.; Willis, Peter A.

    2013-01-01

    There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given

  13. Genomic networks of hybrid sterility.

    Science.gov (United States)

    Turner, Leslie M; White, Michael A; Tautz, Diethard; Payseur, Bret A

    2014-02-01

    Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities"). The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus) provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL). Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is applicable in a broad

  14. Radiation sterilization of skin allograft

    International Nuclear Information System (INIS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-01-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6 . The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2 . The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  15. Radiation sterilization of skin allograft

    Science.gov (United States)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  16. Why are rates of sterilization in decline? A pilot study designed to explore reasons for declining female sterilization in Scotland.

    Science.gov (United States)

    Chen, Zhong E; Glasier, Anna; Warner, Pamela

    2008-10-01

    In the last decade, female sterilization had been in decline throughout the UK. It is not clear whether fewer women are requesting sterilization or whether the universal enthusiasm for long-acting reversible methods is leading health professionals to discourage women from being sterilized. Since correct and consistent use of alternative, reversible contraceptive methods depends somewhat on their acceptability, it is important to determine whether women are being refused sterilization or whether they are freely choosing other methods. This study aims to explore whether female sterilization is being widely considered as a contraceptive method, the reasons for choosing or rejecting it, and whether women are being discouraged by health professionals from being sterilized. A self-completed questionnaire survey among 205 women aged 30 to 50 years who felt that their family was complete attending a family planning clinic in Scotland. Of the 203 women included in the study, 151 (74.4%) had heard of female sterilization, 90 had discussed it with someone (60%) and 87 (58%) had considered it as a contraceptive option. Of the 56 women who consulted their family doctor about sterilization, almost half (27; 48%) were not referred to a hospital and fewer than one (17, 30.4%) in three of them was eventually sterilized or had arrangements in place to get it done. Free-text comments from the women revealed a variety of reasons for not choosing female sterilization and suggested that some women are being deterred from sterilization. The study suggests that some women are being actively encouraged by health professionals to use long-acting reversible contraceptive methods and discouraged from choosing sterilization. However, other women recognize for themselves the wisdom of keeping their fertility options open.

  17. Cryoradiation sterilization - contemporary state and outlook

    International Nuclear Information System (INIS)

    Talrose, V.L.

    1995-01-01

    The new approach of radiation sterilization -cryoradiosterilization with programmed freezing - was developed for pharmaceutical solutions. Both scientific and technical problems are solved, the results are discussed. Programmed freezing of vials with the drug's solutions provides the high stability of soluted components with biological activity at sterilizing irradiation without significant change of sterilization doses. Physical, chemical, biological and pharmacological properties of a lot of drug solutions for injection satisfy official requirements after cryoradiation sterilization treatment. This method seems to be especially important for the protein systems which could be infected by dangerous viruses (VIH, hepatitis B): blood plasma, diagnostic sera, protein preparations manufactured from donor's blood, etc. (Author)

  18. Energy storage connection system

    Science.gov (United States)

    Benedict, Eric L.; Borland, Nicholas P.; Dale, Magdelena; Freeman, Belvin; Kite, Kim A.; Petter, Jeffrey K.; Taylor, Brendan F.

    2012-07-03

    A power system for connecting a variable voltage power source, such as a power controller, with a plurality of energy storage devices, at least two of which have a different initial voltage than the output voltage of the variable voltage power source. The power system includes a controller that increases the output voltage of the variable voltage power source. When such output voltage is substantially equal to the initial voltage of a first one of the energy storage devices, the controller sends a signal that causes a switch to connect the variable voltage power source with the first one of the energy storage devices. The controller then causes the output voltage of the variable voltage power source to continue increasing. When the output voltage is substantially equal to the initial voltage of a second one of the energy storage devices, the controller sends a signal that causes a switch to connect the variable voltage power source with the second one of the energy storage devices.

  19. MINOS Sterile Neutrino Search

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, David Jason [Univ. College London, Bloomsbury (United Kingdom)

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  20. Observations on female sterilization in Chile.

    Science.gov (United States)

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical

  1. Improvement of voltage stability in wind farm connection to distribution network using FACTS devices

    Energy Technology Data Exchange (ETDEWEB)

    Salehi, V.; Kahrobaee, S.; Afsharnia, S. [School of Electrical and Computer Engineering, ECE, University of Tehran (Iran)

    2006-07-01

    Increasing capacity of connected wind power generation to utilities brings new opportunities and also problems to the utilities and customers. Evolution and analyzing of the connection conditions and effects of wind farms especially on remote areas are the main aspects of developing wind power on the utilities. The problem is that these wind turbine that mostly uses induction generators, tend to drain large amounts of VARs from the grid, potentially causing low voltage and maybe voltage stability problems for the utility owner, especially in the case of large load variation on distribution feeder. To investigate the impact of large wind farms on power system voltage stability, one of the Iran's wind farms is modeled in DIgSILENT software and the simulation results shows the effect of using FACTS devices including SVC and STATCOM on power system performance. (orig.)

  2. Use of sterile insect technique in Brazil by the sterilization of Ceratitis capitata (Wied., 1824)

    International Nuclear Information System (INIS)

    Okeese, G.O.; Kitomer, T.J.; Gayaradus, L.B.; Etrigan, M.; Jansen, C.W.J.H.; Houlahar, H.L.

    2006-01-01

    The Sterile Insect Technique is a method of pest control allowed in Integrated Pest Management programs in fruit growing, where sterile insects released compete in mate process against fertile wild ones, generating a gradative population reduction. The most used sterilization method is using ionizing radiation from 60 Co or 137 Cs. For efficient application of SIT, an important item is the sterilizing dose. This must be as lower as possible in order to preserve insect behavior. In this work, it was studied the reproductive potential of fruit fly Ceratitis capitata, tsl VIENNA 8 strain, irradiated with different doses of gamma radiation. This strain has been used in population suppression programs at fruit-growing areas from Northeast of Brazil, through a partnership between CENA and Bio factory MOSCAMED Brazil, intending only sterile male releases. Radiation source used was a 60 Co irradiator, with 17.2 x 1012 Bq. Individualized couples were distributed in a randomized delineament with 10 replicates for each treatment and eggs were collected for fifteen days. With 9 and 10 days old, pupae were irradiated with doses ranging from 30 to 120 Gy. All averages of emerged adult's percentages were higher than 90%. In regards to fecundity, different doses did not affect the number of eggs laid, being the overall mean around 30 eggs/couple/day. Fertility data showed that as radiation dose increases, sterility increases. It was concluded that the dose of 90 Gy can be used in Brazil, since to SIT programs a dose is chosen witch prevents an egg hatch higher than 1%. (author)

  3. 1 1/2 years of experience with a 10 MeV self-shielded on-line e-beam sterilization system

    International Nuclear Information System (INIS)

    Lambert, Byron; Tang, Fuh-Wei; Riggs, Brian; Allen, Thomas; Williams, C.B.

    2000-01-01

    The Vascular Intervening Group of the Guidant Corporation (Guidant IV) has been operating a self-shielded, 10 MeV 4 kW, electron beam sterilization system since July of 1988. The system was designed, built and installed in a 70 square meter area in an existing Guidant manufacturing facility by Titan Scan Corporation and performance of the system was validated in conformance with 1S0-11137 standards. The goal of this on-site e-beam system was 'just in time' JIT, sterilization, i.e. the ability to manufacture, sterilize and ship, high intrinsic value medical devices in less than 24 hours. The benefits of moving from a long gas sterilization cycle of greater than one week to a JIT process were envisioned to be a) speed to market with innovated new products b) rapid response to customer requirements c) reduced inventory carrying costs and finally manufacturing and quality system efficiency. The ability of Guidant to realize these benefits depended upon the ability of the Guidant VI business units to adapt to the new sterilization modality and functionality and on the overall system reliability. This paper reviews the operating experience to date and the overall system reliability. (author)

  4. Sterilization of heparinized cuprophan hemodialysis membranes

    OpenAIRE

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated. Sterilization did not result in a release of heparin or heparin fragments from heparinized Cuprophan. Sterilization of heparinized Cuprophan by means of EtO exposure and gamma irradiation induced a slight, i...

  5. EB surface sterilization of food material

    International Nuclear Information System (INIS)

    Kaneko, H.; Mizutani, A.; Kato, K.; Nishikimi, T.; Taniguchi, S.

    2001-01-01

    In this paper, we introduce a food irradiation with low energetic, lower than 300keV, electrons (so-called SOFT ELECTRON) as a rather new method of food sterilization. It is also a physical sterilization method, and free from the problems mentioned above. Low energetic electrons have small penetration power (50-200micron) through raw materials, and by selecting a proper energy of electrons we can sterilize only the surfaces or skins of target materials

  6. Genetic basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Robinson, A.S.

    2005-01-01

    The use of the sterile insect technique (SIT) for insect control relies on the introduction of sterility in the females of the wild population. This sterility is produced following the mating of these females with released males carrying, in their sperm, dominant lethal mutations that have been induced by ionizing radiation. The reasons why the SIT can only be effective when the induced sterility in the released males is in the form of dominant lethal mutations, and not some form of sperm inactivation, are discussed, together with the relationship of dominant lethal mutations to dose, sex, developmental stage and the particular species. The combination of genetic sterility with that induced by radiation is also discussed in relation to the use of genetic sexing strains of the Mediterranean fruit fly Ceratitis capitata (Wiedemann) in area-wide integrated pest management (AW-IPM) programmes that integrate the SIT. A case is made to lower the radiation dose used in such programmes so as to produce a more competitive sterile insect. Increased competitiveness can also be achieved by using different radiation environments. As well as radiation-induced sterility, natural mechanisms can be recruited, especially the use of hybrid sterility exemplified by a successful field trial with tsetse flies Glossina spp. in the 1940s. Genetic transformation will make some impact on the SIT, especially regarding the introduction of markers for released flies, and the construction of genetic sexing strains. It is concluded that using a physical process, such as radiation, will always have significant advantages over genetic and other methods of sterilization for the large-scale application of the SIT. (author)

  7. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice

    NARCIS (Netherlands)

    El-Namaky, R.; Oort, van P.A.J.

    2017-01-01

    Background: There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two

  8. Genomic networks of hybrid sterility.

    Directory of Open Access Journals (Sweden)

    Leslie M Turner

    2014-02-01

    Full Text Available Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities". The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL. Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  9. Comparative mating and reproductive performance of radiation sterilized and radiation induced F1 sterile males of Earias vittella (Fabricius)

    International Nuclear Information System (INIS)

    Shantharam, K.; Tamhankar, A.J.; Harwalkar, M.R.

    1995-01-01

    Studies were conducted on mating behaviour and reproductive performance of a) Earias vittella (F.) males rendered sterile by exposing them to 300 Gy gamma rays and b) F 1 sterile males obtained by exposing parent male to 100 Gy gamma rays. For the study, males were allowed only one mating with a normal female. Results revealed that premating period, period in copula and per cent insects mating were not adversely affected in case of both types of sterile males and fecundity also remained unaffected. However, in both types of sterile males, incidence of spermatophore transfer without sperm was very large and such an occurrence (including reduced spermatophore transfer) was significantly higher in case of radiation sterilized males compared to the F 1 sterile males. Inability to produce and transfer spermatophore and/or sperm appeared to be a major cause behind the reduced mating competitiveness of both types of males. (author). 22 refs., 2 tabs

  10. Emerging materials and devices in spintronic integrated circuits for energy-smart mobile computing and connectivity

    International Nuclear Information System (INIS)

    Kang, S.H.; Lee, K.

    2013-01-01

    A spintronic integrated circuit (IC) is made of a combination of a semiconductor IC and a dense array of nanometer-scale magnetic tunnel junctions. This emerging field is of growing scientific and engineering interest, owing to its potential to bring disruptive device innovation to the world of electronics. This technology is currently being pursued not only for scalable non-volatile spin-transfer-torque magnetoresistive random access memory, but also for various forms of non-volatile logic (Spin-Logic). This paper reviews recent advances in spintronic IC. Key discoveries and breakthroughs in materials and devices are highlighted in light of the broader perspective of their application in low-energy mobile computing and connectivity systems, which have emerged as leading drivers for the prevailing electronics ecosystem

  11. PROCESS OF ELECTRICAL CONNECTION OF PHOTOVOLTAIC DEVICES

    DEFF Research Database (Denmark)

    2012-01-01

    A photovoltaic cell module comprising at least two serially connected photovoltaic cells on a common substrate, wherein the cells each comprise a first electrode layer, a first charge selective layer, a light harvesting layer which comprises an organic conjugated polymer, and a second charge...... of the pair, which connection is made through the light harvesting layer common to the at least one pair of cells, without forming an electrical connection with the first electrode of the first cell or the second charge selective layer of the second cell; and a method of making such a photovoltaic cell module....... selective layer is formed such that the second charge selective layer of one cell has no direct electrical connection to the second charge selective layer of any other cell, and wherein the light-harvesting layer is formed such that it is common to at least one pair of adjacent cells of the module; wherein...

  12. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene.

    Science.gov (United States)

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-12-06

    The breeding and large-scale adoption of hybrid seeds is an important achievement in agriculture. Rice hybrid seed production uses cytoplasmic male sterile lines or photoperiod/thermo-sensitive genic male sterile lines (PTGMS) as female parent. Cytoplasmic male sterile lines are propagated via cross-pollination by corresponding maintainer lines, whereas PTGMS lines are propagated via self-pollination under environmental conditions restoring male fertility. Despite huge successes, both systems have their intrinsic drawbacks. Here, we constructed a rice male sterility system using a nuclear gene named Oryza sativa No Pollen 1 (OsNP1). OsNP1 encodes a putative glucose-methanol-choline oxidoreductase regulating tapetum degeneration and pollen exine formation; it is specifically expressed in the tapetum and miscrospores. The osnp1 mutant plant displays normal vegetative growth but complete male sterility insensitive to environmental conditions. OsNP1 was coupled with an α-amylase gene to devitalize transgenic pollen and the red fluorescence protein (DsRed) gene to mark transgenic seed and transformed into the osnp1 mutant. Self-pollination of the transgenic plant carrying a single hemizygous transgene produced nontransgenic male sterile and transgenic fertile seeds in 1:1 ratio that can be sorted out based on the red fluorescence coded by DsRed Cross-pollination of the fertile transgenic plants to the nontransgenic male sterile plants propagated the male sterile seeds of high purity. The male sterile line was crossed with ∼1,200 individual rice germplasms available. Approximately 85% of the F1s outperformed their parents in per plant yield, and 10% out-yielded the best local cultivars, indicating that the technology is promising in hybrid rice breeding and production.

  13. Bladder perforation owing to a unipolar coagulating device.

    Science.gov (United States)

    Pakter, J; Budnick, L D

    1981-09-15

    A report on a patient who sustained a burn and perforation of the urinary bladder from visible sparks emanating from a unipolar coagulating device during the couse of laparoscopic sterilization is presented. It is the first report of urinary bladder burns using a unipolar coagulating device. A 24-year-old woman, gravida 10, para 3, abortus 7, underwent a laparoscopic sterilization with a unipolar coagulating device. As the physician was finishing the coagulation, a spark from the device caused a 1-2 cm burn with a central area of perforation into the urinary bladder. Conservative treatment was recommended, and consisted of Foley catheterization and drainage for 5 days. Initial urine culture revealed Klebsiella species, and oral ampicillin was prescribed. Hematuria was noted throughout the patient's hospitalization, and blood clots were present in the urine on Day 2 postoperation. The patient had no abdominal or flank pain, was afebrile, and had a stable hemoglobin level during the hospital stay. Cystography was performed on Day 5 postoperatively and demonstrated no perforation. Foley catheter was removed. Patient was discharged 2 days later and remains in good health 3 months postoperatively.

  14. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  15. Sterile neutrinos as dark matter

    International Nuclear Information System (INIS)

    Dodelson, S.; Widrow, L.M.

    1994-01-01

    The simplest model that can accommodate a viable nonbaryonic dark matter candidate is the standard electroweak theory with the addition of right-handed (sterile) neutrinos. We consider a single generation of neutrinos with a Dirac mass μ and a Majorana mass M for the right-handed component. If M much-gt μ (standard hot dark matter corresponds to M=0), then sterile neutrinos are produced via oscillations in the early Universe with energy density independent of M. However, M is crucial in determining the large scale structure of the Universe; for M∼100 eV, sterile neutrinos make an excellent warm dark matter candidate

  16. Radio sterilized human ligaments and their clinical application

    International Nuclear Information System (INIS)

    Luna Z, D.; Reyes F, M. L.; Diaz M, I.; Hernandez R, G.

    2009-10-01

    The ligaments are human tissues that are used in the transplantation area. A ligament is an anatomical structure in band form, composed by resistant fibers that connect the tissues that unite the bones with the articulations. In an articulation, the ligaments allow and facilitate the movement inside the natural anatomical directions, while it restricts those movements that are anatomically abnormal, impeding lesions that could arise of this type of movements. The kneecap ligament is a very important tissue in the knee mobility and of walking in the human beings. This ligament can injure it because of automobile accidents, for sport lesions or illnesses, and in many cases the only form of recovering the knee movement is carried out a transplant with the purpose of replacing the damage ligament by allo gen kneecap ligament processed in specialized Tissue Banks where the tissue is sterilized with gamma radiation of 60 Co at very low temperatures, obtaining high quality ligaments for clinical application in injured patients. The kneecap ligaments are processed in the Tissue Banks with a segment of kneecap bone, a segment of tibial bone, the contained ligament between both bones and in some cases a fraction of the quadriceps tendon. In this work is given a description of the selection method of the tissue that includes the donor's serologic control, the kneecap ligament processing in the Radio Sterilized Tissues Bank, its sterilization with gamma radiation of 60 Co, also it is indicated like the clinical application of the allo gen ligament was realized in a hasty patient and whose previous crossed ligament was injured. Finally the results are presented from the tissue obtaining until the clinical application of it is, and in this case is observed a favorable initial evolution of the transplantation patient. (Author)

  17. Exploiting novel sterilization techniques for porous polyurethane scaffolds.

    Science.gov (United States)

    Bertoldi, Serena; Farè, Silvia; Haugen, Håvard Jostein; Tanzi, Maria Cristina

    2015-05-01

    Porous polyurethane (PU) structures raise increasing interest as scaffolds in tissue engineering applications. Understanding the effects of sterilization on their properties is mandatory to assess their potential use in the clinical practice. The aim of this work is the evaluation of the effects of two innovative sterilization techniques (i.e. plasma, Sterrad(®) system, and ozone) on the morphological, chemico-physical and mechanical properties of a PU foam synthesized by gas foaming, using water as expanding agent. In addition, possible toxic effects of the sterilization were evaluated by in vitro cytotoxicity tests. Plasma sterilization did not affect the morphological and mechanical properties of the PU foam, but caused at some extent degradative phenomena, as detected by infrared spectroscopy. Ozone sterilization had a major effect on foam morphology, causing the formation of new small pores, and stronger degradation and oxidation on the structure of the material. These modifications affected the mechanical properties of the sterilized PU foam too. Even though, no cytotoxic effects were observed after both plasma and ozone sterilization, as confirmed by the good values of cell viability assessed by Alamar Blue assay. The results here obtained can help in understanding the effects of sterilization procedures on porous polymeric scaffolds, and how the scaffold morphology, in particular porosity, can influence the effects of sterilization, and viceversa.

  18. Twelve-year retrospective review of unintended pregnancies after Essure sterilization in the Netherlands.

    Science.gov (United States)

    Hitzerd, Emilie; Schreuder, Henk W R; Vleugels, Michel P H; Veersema, Sebastiaan

    2016-04-01

    To identify factors contributing to the occurrence of unintended pregnancies after Essure sterilization in the Netherlands. Even though Essure is a permanent method of contraception, unintended pregnancies have been reported. Retrospective case series analysis. Not applicable. Thirty-five pregnancies were reported in the Netherlands after Essure sterilization from 2002 through 2014 out of 27,346 placements. Data regarding Essure placement procedure, confirmation tests, and pregnancy outcome of the reported cases were obtained and analyzed to identify a possible cause of failure. Four causes of failure were identified: perforation (n = 10), expulsion (n = 7), unilateral placement (n = 7), and luteal pregnancy (n = 2). The occurrence of most pregnancies was related to physician noncompliance (n = 14). The other cases were associated with patient noncompliance (n = 5) or misinterpretation of the confirmation test (n = 9). Most pregnancies occurred within the first 24 months after the 3-month confirmation test (n = 23). The results of this study show that the incidence of pregnancies after Essure sterilization is low. Most pregnancies were related to incorrect positioning of a device or unilateral placement, and seem therefore preventable. Unilateral placement without prior history of salpingectomy should always be considered as unsuccessful sterilization. Furthermore, interpretation of the confirmation tests should be done by trained physicians, and with caution. We want to emphasize the importance of strictly adhering to placement and follow-up protocols. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  19. Hysteroscopic tubal sterilization: a health economic literature review.

    Science.gov (United States)

    2013-01-01

    fallopian tubes, preventing the egg from moving down the tube and the sperm from reaching the egg. Tubal ligation is a surgical procedure to tie or seal the fallopian tubes, and it usually requires general anesthesia. In contrast, hysteroscopic tubal sterilization can be performed in 10 minutes in an office setting without general or even local anesthesia. A tiny device called a microinsert is inserted into each fallopian tube through the vagina, cervix, and uterus without surgery. An instrument called a hysteroscope allows the doctor to see inside the body for the procedure. Once the microinserts are in place, scar tissue forms around them and blocks the fallopian tubes. Health Quality Ontario commissioned a systematic review of published economic literature to determine whether hysteroscopic sterilization is cost-effective compared to tubal ligation. This review did not find any studies that reported results in terms of both costs and effectiveness or costs and quality-adjusted life-years. We did find 3 costing studies and included them in our review. All of these studies found that when hysteroscopic sterilization was performed as an outpatient procedure, it was less expensive than tubal ligation due to a shorter recovery time. However, none of the studies apply directly to Ontario because of differences in our health care system compared to those in the studies.

  20. Application of radiation sterilization to bone allografts

    International Nuclear Information System (INIS)

    Li Youchen; Li Baoxing; Sun Shiquan

    2003-01-01

    With prominent features of high penetration, no temperature increases, no harm residues and easy dose control, radiation sterilization technology is widely used in the sterilization of bone allografts. During the radiation sterilization of bone allografts, the irradiation dose should be optimized to ensure sterilization of grafts and preservation of biological properties of bone. The immunogenicity of allografts is decreased by irradiation. IAEA devoted great efforts to generalization of the radiation sterilization of tissue allografts in developing countries since 1986. Tissue Bank of China Institute for Radiation Protection (CIRP) was initially established in 1988 with the support of IAEA, afterwards restructured into Shanxi Provincial Tissue Bank (SPTB). The SPTB, as the first manufacturer of the irradiated bone allografts in the country, was granted production license by the State Food and Drug Administration of China. The SPTB sponsored IAEA/RCA Training Courses, National Symposium on Bone Grafting, and National Training Course on Bone Banking. Technique of radiation sterilization for bone grafts has become popularized in China after these activities. (authors)

  1. Connected vehicle standards.

    Science.gov (United States)

    2016-01-01

    Connected vehicles have the potential to transform the way Americans travel by : allowing cars, buses, trucks, trains, traffic signals, smart phones, and other devices to : communicate through a safe, interoperable wireless network. A connected vehic...

  2. Radiation treatment for sterilization of packaging materials

    International Nuclear Information System (INIS)

    Haji-Saeid, Mohammad; Sampa, Maria Helena O.; Chmielewski, Andrzej G.

    2007-01-01

    Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology

  3. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    Science.gov (United States)

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs.

  4. [Determinants of sterilization among married couples in Korea].

    Science.gov (United States)

    Kim, Ju Hee; Chung, Woojin; Lee, Sunmi; Suh, Moonhee; Kang, Dae Ryong

    2007-11-01

    The purpose of this study was to examine the determinants of sterilization in South Korea. This study was based on the data from the Korea National Fertility Survey carried out in the year 2000 by the Korea Institute of Health and Social Affairs. The subjects of the analysis were 4,604 women and their husbands who were in their first marriage, in the age group of 15-49 years. The data were analyzed by multiple logistic regression analysis. Consistent with the findings of previous studies, the woman's age and the number of total children increased the likelihood of sterilization. In addition, the year of marriage had a strong positive association with sterilization. Interestingly, the number of surviving sons tended to increase the likelihood of sterilization, whereas the woman's education level and age at the time of marriage showed a negative association with sterilization. Religion, place of residence, son preference, and the husband's education level, age and type of occupation were not significant determinants of sterilization. The sex of previous children and lower level of education are distinct determinants of sterilization among women in South Korea. More studies are needed in order to determine the associations between sterilization rate and decreased fertility.

  5. Studies on induced mutation of sesame male sterility

    International Nuclear Information System (INIS)

    Li Yingde; Feng Xiangyun; Zhao Yingzhong

    2001-01-01

    The dry seeds of the high yielding cultivar, Yuzhi-4, were irradiated with 300, 500 and 700 Gy of 60 Co- gamma rays. 3277 M 1 plants were harvested separately as single plants and also in bulk, by doses. In M 2 , the single plant seeds were grown in progeny rows and the bulked seeds were grown as bulks. 25 male sterile plants were screened from M 2 . 10 of the 25 male sterile plants were from the progenies of the single plant seeds and 15 were from the progenies of the bulked seeds. In further genetic research of the 25 male sterile plants in M 3 and M 4 , 6 separate genic male sterile (GMS) lines were identified. Their male sterility was stable and was controlled by a pair of alleles, male fertility being dominant to sterility. (author)

  6. A see-saw mechanism with light sterile neutrinos

    International Nuclear Information System (INIS)

    McKellar, B.H.J.; Garbutt, M.; Stephenson, G.J.; Goldman, T.

    2001-01-01

    The usual see-saw mechanism for the generation of light neutrino masses is based on the assumption that all of the flavours of right-handed (more properly, sterile) neutrinos are heavy. If the sterile Majorana mass matrix is singular, one or more of the sterile neutrinos will have zero mass before mixing with the active (left-handed) neutrinos and be light after that mixing is introduced In particular, a rank 1 sterile mass matrix leads naturally to two pseudo-Dirac pairs, one very light active Majorana neutrino and one heavy sterile Majorana neutrino. For any pattern of Dirac masses, there exists a region of parameter space in which the two pseudo-Dirac pairs are nearly degenerate in mass. This, in turn, leads to large amplitude mixing of active states as well as mixing into sterile states

  7. Cosmology seeking friendship with sterile neutrinos

    International Nuclear Information System (INIS)

    Hamann, J.; Hannestad, S.; Raffelt, G.G.; Tamborra, I.; Wong, Y.Y.Y.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile neutrino states from the most recent cosmological data. Our results are compatible with the existence of one or perhaps two sterile neutrinos, as suggested by LSND and MiniBooNE, if ms is in the sub-eV range.

  8. Sterilization of solutions for parenterals products. Problem analysis

    Directory of Open Access Journals (Sweden)

    Yanelys Montes-González

    2017-09-01

    Full Text Available The solutions for the formulation of parenteral products must be sterile before the aseptic formulation process. For this reason, different methods of sterilization referred in the literature are analyzed. Thermodynamic criteria that rule the sterilization are presented. Furthermore, previous experiences in the sterilization of solutions for the formulation of parental products in an autoclave are analyzed, that take large time of processing and only low volumes of solution can be handled. Using jacketed stirred tanks for the sterilization may solve the problem and, therefore, criteria for the design of the later that allow to process high volumes of solution for the formulation of parenteral products are shown.

  9. Management of complications encountered with Essure hysteroscopic sterilization: a systematic review.

    Science.gov (United States)

    Adelman, Marisa R; Dassel, Mark W; Sharp, Howard T

    2014-01-01

    Essure hysteroscopic sterilization has been US Food and Drug Administration-approved in the United States since 2002. Complications associated with the Essure device include improper placement (malpositioning), unintended pregnancy, pain, infection, and nickel allergy. The rarity of complications, compounded by underreporting, makes it difficult to determine best practices insofar as management. This systematic review synthesizes the national and global experience with management of Essure-related complications and suggests treatment options when data allow. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  10. A novel steam explosion sterilization improving solid-state fermentation performance.

    Science.gov (United States)

    Zhao, Zhi-Min; Wang, Lan; Chen, Hong-Zhang

    2015-09-01

    Traditional sterilization of solid medium (SM) requires lengthy time, degrades nutrients, and even sterilizes inadequately compared with that of liquid medium due to its low thermal conductivity. A novel sterilization strategy, high-temperature and short-time steam explosion (SE), was exploited for SM sterilization in this study. Results showed that SE conditions for complete sterilization were 172 °C for 2 min and 128 °C for 5 min. Glucose and xylose contents in medium after SE sterilization increased by 157% and 93% respectively compared with those after conventional sterilization (121 °C, 20 min) while fermentation inhibitors were not detected. FTIR spectra revealed that the mild SE conditions helped to release monosaccharides from the polysaccharides. Bacillus subtilis fermentation productivity on medium after SE sterilization was 3.83 times of that after conventional sterilization. Therefore, SE shortened sterilization time and improved SM nutrition, which facilitated fermentability of SM and should promote economy of solid-state fermentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. profile of intrauterine contraceptive device acceptors at the university

    African Journals Online (AJOL)

    ANNALS

    Conclusion: The acceptors of intrauterine contraceptive devices in our center were ... Conclusion: Les accepteurs de la contraception de substances médicamentenses dans notre centre .... sterilization due to cultural reasons is very low,13 the.

  12. Gene, protein and network of male sterility in rice

    Directory of Open Access Journals (Sweden)

    Wang eKun

    2013-04-01

    Full Text Available Rice is one of the most important model crop plants whose heterosis has been well exploited in commercial hybrid seed production via a variety of types of male sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and proteins related to cytoplasmic male sterility, photoperiod sensitive male sterility, self-incompatibility and other types of microspores deterioration have been characterized through genetics or proteomics. Especially the latter, offers us a powerful and high throughput approach to discern the novel proteins involving in male-sterile pathways which may help us to breed artificial male-sterile system. This represents an alternative tool to meet the critical challenge of further development of hybrid rice. In this paper, we reviewed the recent developments in our understanding of male sterility in rice hybrid production across gene, protein and integrated network levels, and also, present a perspective on the engineering of male sterile lines for hybrid rice production.

  13. Sewage sterilization through gamma radiation

    International Nuclear Information System (INIS)

    Vieira, D.V.; Teixeira, W.M.S.; Silva, F.C.A. da

    2017-01-01

    Lack of sewage treatment and adequate sanitation conditions can contribute to the proliferation of numerous parasitic and infectious diseases in addition to water degradation. Approximately fifty types of infections can be transmitted from a sick to a healthy person through different pathways involving human excreta. Untreated sewage can contaminate water, food, hands, soil, etc. Epidemics of certain diseases such as typhoid, cholera, dysenteries, etc., and countless cases of worms are responsible for high mortality rates in third world countries. In the work the different techniques of sewage treatment by disinfestation and sterilization were analyzed, highlighting the use and the advantages of the gamma radiation as well as the aspects of the radiological protection involved. The technique of sewage sterilization using gamma radiation is a method of controlling bacteria and microorganisms. It is estimated that more than 200 large irradiators are in operation worldwide, of which 5 are in Brazil, for general sterilization use. These facilities use a large amount of radioactive material, in the order of millions of Becquerel, for sterilization with high doses of radiation, which can generate lethal doses in a few minutes. These industrial facilities use Cobalt-60, being classified by the International Atomic Energy Agency - IAEA as Category 1 of high risk, and must possess a high level of radiological protection to carry out the sterilization, standing out the defense in depth. Specific legislation on radiological protection should be drafted for safe work and avoid future radiation accidents

  14. Searching for Sterile Neutrinos with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Timmons, Ashley [Manchester U.

    2016-01-01

    This document presents the latest results for a 3+1 sterile neutrino search using the $10.56 \\times 10^{20}$ protons-on-target data set taken from 2005 - 2012. By searching for oscillations driven by a large mass splitting, MINOS is sensitive to the existence of sterile neutrinos through any energy dependent deviations using a charged current sample, as well as looking at any relative deficit between neutral current events between the far and near detectors. This document will discuss the novel analysis that enabled a search for sterile neutrinos setting a limit in the previously unexplored regions in the parameter space $\\{\\Delta m^{2}_{41}, \\sin^2\\theta_{24}\\}$. The results presented can be compared to the parameter space suggested by LSND and MiniBooNE and complements other previous experimental searches for sterile neutrinos in the electron neutrino appearance channel.

  15. Ionizing radiation for sterilization of medical products and biological tissues

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S K; Raghevendrarao, M K [Bhabha Atomic Research Centre, Bombay (India). Library and Technical Information Section

    1975-10-01

    The article reviews the deliberations of the International Symposium on Ionizing Radiation for Sterilization of Medical Products and Biological Tissues which was held during 9-13 December 1974 under the auspices of the IAEA at the Bhabha Atomic Research Centre, Bombay. 42 papers were presented in the following broad subject areas: (1) Microbiological Control aspects of radiation sterilization, (2) Dosimetry aspects of radiation sterilization practices, (3) Effects of sterilizing radiation dose on the constituents of medical products, (4) Application of radiation sterilization of medical products of biological origin, (5) Technological aspects of radiation sterilization facilities, (6) Radiation sterilization of pharmaceutical substances, (7) Reports on current status of radiation sterilization of medical products in IAEA member states and (8) Working group discussion on the revision of the IAEA recommended code of practice for radiation sterilization of medical products.

  16. Auditing radiation sterilization facilities

    Science.gov (United States)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  17. Reutilização simulada de produtos médico-hospitalares de uso único, submetidos à esterilização com óxido de etileno Simulated reuse of single use medical devices submitted to ethylene oxide sterilization

    Directory of Open Access Journals (Sweden)

    Mônica Valero da Silva

    2005-06-01

    bacterial endotoxin (200 EU/device. The B. subtilis contaminated specimen samples had been washed, rinsed, dried and sterilized with ETO/CFC 12:88. Those contaminated with bacterial endotoxin had been submitted to drying, repacking and sterilization. After each cycle, ten units, contaminated with B. subtilis, had been evaluated by microbial counting test, sterility test, in vitro cytotoxicity and scanning electron microscopy. Those contaminated with bacterial endotoxin, three units of each specimen sample, had been submitted to the turbidimetric test, after each cycle. Amongst the units challenged with B. subtilis, viable load of 10³cfu was verified, surface damages were noticed on the specimen samples after tenth reprocessing cycles, but no toxicity was observed. In the other challenge, a gradual increase in recovered percentage of bacterial endotoxin was verified. Taking into consideration the obtained results, we do not recommend reprocessing of single use medical devices.

  18. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by the...

  19. [Preliminary Study of Lonicera hypoglauca on Germination Conditions of Sand Culture Seeds and Sterilization Method of Sand Culture Seedling Sterilization].

    Science.gov (United States)

    Tan, Mu-xiu; Zeng, Wen-wen; Wei, Peng-xiao; Mo, Qiao-cheng; Pu, Zu-ning; Cen, Xiu-fen; Shi, Feng-hua

    2015-05-01

    To explore the germination conditions of Lonicera hypoglauca sand culture seeds and the effects of sand culture seedlings sterilization. 0.1% HgCl2 with different sterilization time, different illumination time and temperature culture condition were adopted to study the germination conditions of sand culture seeds. Different sterilization treatments and different hardening-seedling days were used to test the sterilization effect of sand culture seedlings. The sterilization effect of the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min on Lonicera hypoglauca seeds was the optimum,with the average pollution rate of 15.56%, and the average germination rate reached 51.11%. The combination of varied temperature-room temperature under light for 12 h/d was the best, with the average germination rate peaked at 75.49%, and the average germination potential reached 68.36%. The treatment of detergent liquor scrub-tap water wash on the part above the hypocotyl, which was sand cultured under the opening condition and had no root, showed the best sterilization effect, with the average pollution rate was zero, and the average survival rate peaked at 100.00%. The sterilization effect of sand culture seedlings, which was disinfected after cleaning by detergent liquor scrub-tap water wash after hardening-seeding for 30 days, was the best, with the average pollution rate of 50.00%, and the average survival rate of 100.00%. The best sterilization effect is the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min; Lighting for 12 h/d of varied temperature-room temperature is regarded as the optimum culture condition. The treatment of detergent liquor scrub-tap water wash treatment on the part above the hypocotyl,which is sand cultured under the opening condition and had no root, shows the best sterilization effect. For the sand culture seedlings, before inoculated in subculture medium, should be hardening-seedling for some days and sterilized after detergent liquor scrub-tap water wash.

  20. Endometrial preparation with desogestrel before Essure hysteroscopic sterilization: preliminary study.

    Science.gov (United States)

    Haimovich, Sergio; Mancebo, Gemma; Alameda, Francesc; Agramunt, Silvia; Hernández, José Luis; Carreras, Ramón

    2013-01-01

    To assess the effect of desogestrel on endometrial preparation for transcervical sterilization using the Essure device. Prospective nonrandomized clinical study (Canadian Task Force classification II-3). Acute-care university-affiliated hospital in Barcelona, Spain. Women undergoing sterilization using the Essure device between January 2010 and January 2011. Participants were offered desogestrel, 75 μg/d, for 6 weeks before the procedure. Sixteen who accepted were included in the desogestrel group, and 18 who refused were allocated to the no-treatment group. Endometrial biopsy samples were also obtained. In women who received desogestrel, decidual transformation was observed in eight, glandular atrophy in three, and proliferative endometrium in five. In the no-treatment group, two women had menstruation, nine had proliferative endometrium, and seven had secretory endometrium. In the desogestrel group, the procedure was successful in all women. In the no-treatment group, the procedure was cancelled in two women because of menstruation and in four women with secretory endometrium in whom the tubal ostia were difficult to visualize because of endometrial thickness and bleeding. The median (interquartile range, 25th-75th percentile) duration of the procedure was shorter in the desogestrel group than in the no-treatment group (7 [6-7] minutes vs 8 [7-12] minutes; p = .002). Desogestrel, 75 μg/d, could be an alternative to combined hormonal contraception before placement of Essure inserts, facilitating the procedure and serving as a contraceptive method during the following 12 weeks until occlusion of the tubes. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  1. Sharing Data between Mobile Devices, Connected Vehicles and Infrastructure Task 4 / Task 10 : System Architecture and Design Document (SA/DD).

    Science.gov (United States)

    2017-10-27

    This report describes the system architecture and design of the Experimental Prototype System (EPS) for the demonstration of the use of mobile devices in a connected vehicle environment. Specifically, it defines the system structure and behavior, the...

  2. Effectiveness of various sterilization methods of contaminated post-fitted molar band

    Directory of Open Access Journals (Sweden)

    Anggia Tridianti

    2013-06-01

    Full Text Available Background: Molar band as anchoring device may be contaminated during the fitting process. Thus, decontamination process is essential to prevent cross-infection between patients. Purpose: The objective of this research was to determine the amount of bacteria in molar band post-fitted on the patient teeth, after previously undergone pre-sterilization using alcohol and ultrasonic cleaning bath followed by sterilization using dry heat oven and steam autoclave, in order to find the best method in decontamination of post-fitted molar band. Methods: Four molar bands which already fitted on one patient then divided evenly into two groups. The first group was pre-sterilized using alcohol. One of the bands then sterilized using dry heat oven, while the other one was sterilized using steam autoclave. The second group was pre-sterilized using ultrasonic cleaning bath. One band from this group then sterilized using dry heat oven and the other was sterilized using steam autoclave. The next step was to immerse all the bands in a phosphate-buffered saline solution. Using micropipette, the solution was retrieved and dropped upon a petri dish containing Brain Heart Infusion broth. The dish was then stored in an incubator for 24 hours, prior to counting the number of bacteria existed. The same methods were used to the rest of the patients, with total 128 molar bands from 32 patients. Results: There was a profound difference in numbers of bacteria found between those methods of sterilization. However, there was a non significant difference between the two groups which were at the alcohol-steam autoclave group and at the ultrasonic cleaning bath-steam autoclave group. Conclusion: This study showed that steam autoclave is better than for sterilizing molar band, as it left the minimal amount of bacteria in post-fitted molar band.Latar belakang: Molar band merupakan suatu alat penjangkaran yang dapat mengalami kontaminasi selama proses fitting band, sehingga perlu

  3. Underwater running device

    International Nuclear Information System (INIS)

    Kogure, Sumio; Matsuo, Takashiro; Yoshida, Yoji

    1996-01-01

    An underwater running device for an underwater inspection device for detecting inner surfaces of a reactor or a water vessel has an outer frame and an inner frame, and both of them are connected slidably by an air cylinder and connected rotatably by a shaft. The outer frame has four outer frame legs, and each of the outer frame legs is equipped with a sucker at the top end. The inner frame has four inner frame legs each equipped with a sucker at the top end. The outer frame legs and the inner frame legs are each connected with the outer frame and the inner frame by the air cylinder. The outer and the inner frame legs can be elevated or lowered (or extended or contracted) by the air cylinder. The sucker is connected with a jet pump-type negative pressure generator. The device can run and move by repeating attraction and releasing of the outer frame legs and the inner frame legs alternately while maintaining the posture of the inspection device stably. (I.N.)

  4. Allelic interaction of F1 pollen sterility loci and abnormal chromosome behaviour caused pollen sterility in intersubspecific autotetraploid rice hybrids.

    Science.gov (United States)

    He, J H; Shahid, M Q; Li, Y J; Guo, H B; Cheng, X A; Liu, X D; Lu, Y G

    2011-08-01

    The intersubspecific hybrids of autotetraploid rice has many features that increase rice yield, but lower seed set is a major hindrance in its utilization. Pollen sterility is one of the most important factors which cause intersubspecific hybrid sterility. The hybrids with greater variation in seed set were used to study how the F(1) pollen sterile loci (S-a, S-b, and S-c) interact with each other and how abnormal chromosome behaviour and allelic interaction of F(1) sterility loci affect pollen fertility and seed set of intersubspecific autotetraploid rice hybrids. The results showed that interaction between pollen sterility loci have significant effects on the pollen fertility of autotetraploid hybrids, and pollen fertility further decreased with an increase in the allelic interaction of F(1) pollen sterility loci. Abnormal ultra-structure and microtubule distribution patterns during pollen mother cell (PMC) meiosis were found in the hybrids with low pollen fertility in interphase and leptotene, suggesting that the effect-time of pollen sterility loci interaction was very early. There were highly significant differences in the number of quadrivalents and bivalents, and in chromosome configuration among all the hybrids, and quadrivalents decreased with an increase in the seed set of autotetraploid hybrids. Many different kinds of chromosomal abnormalities, such as chromosome straggling, chromosome lagging, asynchrony of chromosome disjunction, and tri-fission were found during the various developmental stages of PMC meiosis. All these abnormalities were significantly higher in sterile hybrids than in fertile hybrids, suggesting that pollen sterility gene interactions tend to increase the chromosomal abnormalities which cause the partial abortion of male gametes and leads to the decline in the seed set of the autotetraploid rice hybrids. © 2011 The Author(s).

  5. Male sterility in plants. Induction, isolation and utilization

    International Nuclear Information System (INIS)

    Driscoll, C.J.; Barlow, K.K.

    1976-01-01

    Both induced and spontaneously arising male sterility mutants exist in a number of important plant species. These mutants are somewhat unique in that they effect procedures for breeding improved varieties. They allow for the possibility of easily obtaining large numbers of hybrids, population breeding systems and the production of hybrid varieties. These mutants are normally classified as cytoplasmic mutants or chromosomal mutants, the latter also being referred to as nuclear or genic mutants. Specific examples of these types of sterility are examined in relation to the breeding system of the species and their potential use for varietal development. Male sterility in diploid and polyploid species is compared, with reference to gene duplication in polyploids. The mechanism of male sterility is examined in the various species at the anatomical and biochemical levels. Methods of isolating male sterility mutants are compared and a specific example is outlined for hexaploid wheat. Future use of male sterility mutants for improving varieties of various crops is examined. (author)

  6. Evaluation of steam sterilization conditions for [18F]fludeoxyglucose

    International Nuclear Information System (INIS)

    Santos, Priscilla F.; Nascimento, Leonardo T.; Valente, Eduardo S.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z.

    2011-01-01

    [ 18 F]Flu deoxyglucose ( 18 FDG) is the most commonly used radiopharmaceutical for positron emission tomography. Sterile filtration of the final product into sterile vials using 0.22 μm filter membrane is usually adopted for 18 FDG. However, Good Manufacturing Practice (GMP) guidelines recommend heat sterilization as the method of choice to ensure sterility of pharmaceutical preparations. The aim of this study was to essay different steam sterilization conditions in order to choose the best one for 18 FDG. Three different sterilization conditions were essayed. The first one at 121 deg C for 15 minutes, the second one at 135 deg C for 3.5 minutes and the third one at 133 deg C for 2 minutes. 18 FDG pH-formulation was kept around 6.0. At the end of autoclave cycles, 18 FDG sterility was evaluated by direct inoculation of 18 FDG in culture media and radiochemical purity was determined by TLC and HPLC. Results demonstrated that all essayed conditions were able to ensure 18 FDG sterility, but caused a decrease in radiochemical purity of 18 FDG. Autoclave cycle at 133 deg C for 2 minutes was the best essayed condition for 18 FDG terminal sterilization, once it provided the greater radiochemical purity value and took less time. 18 FDG was able to meet specifications after autoclave cycles, what supports the application of steam sterilization in routine 18 FDG production, in compliance with GMP. (author)

  7. Degradation of chitosan-based materials after different sterilization treatments

    International Nuclear Information System (INIS)

    San Juan, A; Montembault, A; Royaud, I; David, L; Gillet, D; Say, J P; Rouif, S; Bouet, T

    2012-01-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  8. Determination of sterilizing dose of lincocine drug

    International Nuclear Information System (INIS)

    Adawi, M.A.; Shamma, M.; Al-Mousa, A.

    1998-01-01

    There are too many antibiotics that have been studied on their dry solid state to determine their safe sterilizing dose by decreasing their bio burden in order to reach the sterility assurance level (SAL) needed. The sterilizing radiating dose of lincocine was determined according to information about their bio burden and radiating sensitivity at the sterility assurance level 10-6. The study of bio burden has shown that the contamination was fungal (Pemicillium sp.) and by applying the same tests to the raw materials of lincocine it came out that the cause of contamination was bad storage and that the radiating dose required to decrease the bio burden was 5.5 kGy. (author)

  9. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period (minutes) Directions T303-b-1 10 lbs 20 Use 28″ vacuum. Steam sterilization is not practical for treatment...

  10. Color stability of shade guides after autoclave sterilization.

    Science.gov (United States)

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  11. Radio-sterilization and processing of frozen human skin

    International Nuclear Information System (INIS)

    Zarate S, Herman; Aguirre H, Paulina; Silva R, Samy; Hitschfeld G, Mario

    2006-01-01

    The Laboratory of Radio-sterilized Biological Tissues Processing (LPTR) belonging to the Chilean Commission of Nuclear Energy and the International Atomic Energy Agency have played a paramount role in our country, concerning the biological tissue processing, which can be radio-sterilized as human skin, pig skin, amniotic membrane, human bone and bovine bone. The frozen radio.-sterilized human skin processing began in 2001, by means of putting into practice the knowledge acquired in training courses through the IAEA and the experience transferred by experts who visited our laboratory. The human skin processing of dead donor can be divided into 6 stages: a) Profuse washing with physiological sterilized serum in to remove the microorganisms, chemical and pharmacological compounds; b) immersion in glycerol solution at 10% to better keep the stored tissues; c) packing, to avoid post manipulation of the sterilized tissue; d) microbiological controls which allow and guarantee a sterility assurance level of 10 6 ; e) radio-sterilization, technique that consists of exposing the grafts to electromagnetic gamma waves which eliminate the microorganisms of the tissue, f) and finally, dispatching and liberation of the frozen sterilized human skin for its clinical use in different centers that take care of burned people. The LPTR receives feedback from surgeons who have used these tissues in order to improve the processing stages based in an integral quality system ISO 9001.2000. The State Health System in our country counts on limited and scarce resources to implement synthetic substitutes that is why It is considered necessary to spread the use of these noble tissues which have sterility assurance and they are processed at low price

  12. The measurement, control, and validation of critical parameters in an electron beam sterilization facility

    International Nuclear Information System (INIS)

    Burns, P.; Drewell, N.H.; McKeown, J.

    1996-01-01

    The delivery and validation of a specified dose to a medical device are key concerns of operators of electron beam irradiation facilities. In an IMPELA-based irradiator, four of the parameters that directly influence the absorbed dose distribution in the product are controllable in real time - the electron energy, average beam current, scanned area, and the product exposure time. The 10 MeV accelerator operates at 50 kW with a stream of 200 μs wide, 100 mA pulses at a repetition rate of 250 Hz. The combination of short-term intra-pulse regulation with long-term pulse-to-pulse stability makes the IMPELA output attractive for the sterilization of medical products. The measurement and closed-loop control techniques used in the IMPELA design will be described with reference to facilitating compliance with medical sterilization standards. (orig.)

  13. Cosmology seeking friendship with sterile neutrinos

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, G.G.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile ...

  14. Male sterile mutant in Vigna radiata

    International Nuclear Information System (INIS)

    Pande, Kalpana; Raghuvanshi, S.S.

    1987-01-01

    Single and combined treatment of γ-rays and 0.25 per cent EMS were tried on Vigna radiata variety K851. A male sterile mutant was isolated in M 2 generation. Experiments indicated male sterility to be recessive and monogenic in nature. 6 figures. (author)

  15. Radiation: A means of sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, R N [International Atomic Energy Agency, Division of Life Sciences, Radiation Biology Section, Vienna (Austria)

    1975-12-15

    The sterilization of medical products by ionizing radiation is a well-established industrial process in a number of technologically advanced countries. It is indeed encouraging to note the rate of growth experienced during the past fifteen years. Starting with the first commercial plant in the early sixties in the USA there are to date more than sixty large facilities of this kind located in USA, Canada, Australia and the countries of Europe including USSR. The geographical distribution of these sterilization plants is rather unbalanced. In this respect Europe is far ahead of the other continents of the world, with about 65% of all sterilization plants, followed by North and South America with 17%, Asia with 8%, Australia and New Zealand with 9% and Africa with only 1%. During the last 10 years the IAEA has actively contributed to the development of radiation sterilization practices and technology in the Member States, with particular emphasis on the developing countries. Such promotional efforts have been made by (a) supporting co-ordinated research to accumulate relevant technical information, (b) organizing scientific meetings and training courses, (c) providing technical expertise in the form of fellowships and expert services, (d) providing technical assistance to conduct market surveys and economic feasibility assessment, (e) scientific publications, including technical manuals and proceedings reports, and (f) assistance in the formulation of an international 'Code of Practice' for standardization of the manufacturing practices for radiation sterilized medical products to meet the specified requirements of the various national Pharmacopoeias and of the international consumer market.

  16. Reionization in sterile neutrino cosmologies

    Science.gov (United States)

    Bose, Sownak; Frenk, Carlos S.; Hou, Jun; Lacey, Cedric G.; Lovell, Mark R.

    2016-12-01

    We investigate the process of reionization in a model in which the dark matter is a warm elementary particle such as a sterile neutrino. We focus on models that are consistent with the dark matter decay interpretation of the recently detected line at 3.5 keV in the X-ray spectra of galaxies and clusters. In warm dark matter models, the primordial spectrum of density perturbations has a cut-off on the scale of dwarf galaxies. Structure formation therefore begins later than in the standard cold dark matter (CDM) model and very few objects form below the cut-off mass scale. To calculate the number of ionizing photons, we use the Durham semi-analytic model of galaxy formation, GALFORM. We find that even the most extreme 7 keV sterile neutrino we consider is able to reionize the Universe early enough to be compatible with the bounds on the epoch of reionization from Planck. This, perhaps surprising, result arises from the rapid build-up of high redshift galaxies in the sterile neutrino models which is also reflected in a faster evolution of their far-UV luminosity function between 10 > z > 7 than in CDM. The dominant sources of ionizing photons are systematically more massive in the sterile neutrino models than in CDM. As a consistency check on the models, we calculate the present-day luminosity function of satellites of Milky Way-like galaxies. When the satellites recently discovered in the Dark Energy Survey are taken into account, strong constraints are placed on viable sterile neutrino models.

  17. Revisiting cosmological bounds on sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, Aaron C. [Institute for Particle Physics Phenomenology (IPPP), Department of Physics, Durham University, Durham DH1 3LE (United Kingdom); Martínez, Enrique Fernández [Departamento and Instituto de Física Teórica (IFT), UAM/CSIC, Universidad Autonoma de Madrid, C/ Nicolás Cabrera 13-15, E-28049 Cantoblanco, Madrid (Spain); Hernández, Pilar; Mena, Olga [Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Lattanzi, Massimiliano, E-mail: aaron.vincent@durham.ac.uk, E-mail: enrique.fernandez-martinez@uam.es, E-mail: m.pilar.hernandez@uv.es, E-mail: omena@ific.uv.es, E-mail: lattanzi@fe.infn.it [Dipartimento di Fisica e Science della Terra, Università di Ferrara and INFN, sezione di Ferrara, Polo Scientifico e Tecnologico, Edificio C Via Saragat, 1, I-44122 Ferrara (Italy)

    2015-04-01

    We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expected in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.

  18. Experiment for search for sterile neutrino at SM-3 reactor

    Science.gov (United States)

    Serebrov, A. P.; Ivochkin, V. G.; Samoylov, R. M.; Fomin, A. K.; Zinoviev, V. G.; Neustroev, P. V.; Golovtsov, V. L.; Gruzinsky, N. V.; Solovey, V. A.; Cherniy, A. V.; Zherebtsov, O. M.; Martemyanov, V. P.; Zinoev, V. G.; Tarasenkov, V. G.; Aleshin, V. I.; Petelin, A. L.; Pavlov, S. V.; Izhutov, A. L.; Sazontov, S. A.; Ryazanov, D. K.; Gromov, M. O.; Afanasiev, V. V.; Matrosov, L. N.; Matrosova, M. Yu.

    2016-11-01

    In connection with the question of possible existence of sterile neutrino the laboratory on the basis of SM-3 reactor was created to search for oscillations of reactor antineutrino. A prototype of a neutrino detector with scintillator volume of 400 l can be moved at the distance of 6-11 m from the reactor core. The measurements of background conditions have been made. It is shown that the main experimental problem is associated with cosmic radiation background. Test measurements of dependence of a reactor antineutrino flux on the distance from a reactor core have been made. The prospects of search for oscillations of reactor antineutrino at short distances are discussed.

  19. Comparison of postoperative surgical site infection after preoperative marking done with non-sterile stationary grade markers versus sterile surgical markers

    International Nuclear Information System (INIS)

    Mir, Z.A.

    2015-01-01

    Objectives: To compare the frequencies of post- operative surgical site infection after preoperative marking done with non-sterile stationary. grade markers versus sterile surgical markers in the same patient. Design: Randomized control trial. Place and Duration of Study: The department of Plastic surgery, Mayo hospital, Lahore from August 2013 to August 2014. Methods: This study was conducted after taking approval from the departmental ethical committee. Forty consecutive patients were included. A sterile surgical marker was used to mark one incision site while an alcohol based stationary grade marker was used to mark another incision site on the same patient. A standard preoperative, intraoperative and postoperative protocol was followed. Cultures were performed on swabs taken from the incision sites and surgical site infection was assessed for 30 days. Results: The study included 40 patients; 17 males and 23 females. The mean age of subjects was 25.32 ± 19.69 years with the minimum age being 2 years and the maximum being 63 years. No growth was seen in cultures taken from all the incision sites after skin preparation in the non sterile stationary grade marker group as well as the sterile surgical grade marker group. Also no surgical site infection appeared during the 30 day postoperative observation period in the non sterile stationary grade marker group as well as the sterile surgical grade marker group. (author)

  20. Light Sterile Neutrinos: A White Paper

    DEFF Research Database (Denmark)

    Abazajian, K. N.; Acero, M. A.; Agarwalla, S. K.

    2012-01-01

    This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.......This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data....

  1. Sterilization of fruit flies (Diptera: Tephritidae) with X-rays for sterile insect technique programs

    International Nuclear Information System (INIS)

    Mastrangelo, Thiago de Araujo

    2009-01-01

    Recent fear of acts of terrorism provoked an increase of delays and denials in the shipment of radioisotopes. This truly represented a menace to sterile insect production projects around the world. In order to validate the use of a new kind of low-energy Xray irradiator, a series of radiobiological studies on Ceratitis capitata (tsl-VIENNA 8 strain) (Wied., 1824) (Diptera: Tephritidae) and an Argentinean strain of Anastrepha fraterculus (Wied., 1830) (Diptera: Tephritidae) were carried out, also comparing biological effectiveness between X-rays and traditional γ radiation from 60 Co. Pupae 48- 24 h before adult emergence of C. capitata males and both sexes of A. fraterculus were irradiated with doses ranging from 15 to 120 Gy and 10 to 70 Gy respectively. Doses that induce 50, 90 and 99% of sterility were estimated and the hypothesis of Parallelism for the Probit equations was tested. Doses of 82.7 Gy of X-rays and 128.2 Gy of γ rays (thus, a RBE∼1.5) induced 99% sterility on medfly males. The fertility of A. fraterculus fertile females crossed with 41 Gy of X-rays and 62.7 Gy of γ rays decreased in 99% comparing with the control group (RBE∼1.5). 99% sterility of A. fraterculus irradiated females was achieved with 60-80 Gy (RBE∼0.7). The standard quality control parameters of fecundity, adult emergence, fliers and survival were not significantly affected by the two types of radiation (RBE∼1) either for medfly or A. fraterculus (p>0.01), being averages in conformity with the values required by FAO/IAEA/USDA. Only fecundity of irradiated A. fraterculus females was severely reduced with increasing doses and no egg was laid at 70 Gy of both radiations. There were no significant differences between X-rays and γ rays regarding mating indices (RSI for medfly, RII, ISI, MRPI and FRPI for A. fraterculus) (p>0.05), what indicated more random matings for fertile and sterile insects. The results demonstrated that no significant difference in biological

  2. Sterilization of Lung Matrices by Supercritical Carbon Dioxide.

    Science.gov (United States)

    Balestrini, Jenna L; Liu, Angela; Gard, Ashley L; Huie, Janet; Blatt, Kelly M S; Schwan, Jonas; Zhao, Liping; Broekelmann, Tom J; Mecham, Robert P; Wilcox, Elise C; Niklason, Laura E

    2016-03-01

    Lung engineering is a potential alternative to transplantation for patients with end-stage pulmonary failure. Two challenges critical to the successful development of an engineered lung developed from a decellularized scaffold include (i) the suppression of resident infectious bioburden in the lung matrix, and (ii) the ability to sterilize decellularized tissues while preserving the essential biological and mechanical features intact. To date, the majority of lungs are sterilized using high concentrations of peracetic acid (PAA) resulting in extracellular matrix (ECM) depletion. These mechanically altered tissues have little to no storage potential. In this study, we report a sterilizing technique using supercritical carbon dioxide (ScCO2) that can achieve a sterility assurance level 10(-6) in decellularized lung matrix. The effects of ScCO2 treatment on the histological, mechanical, and biochemical properties of the sterile decellularized lung were evaluated and compared with those of freshly decellularized lung matrix and with PAA-treated acellular lung. Exposure of the decellularized tissue to ScCO2 did not significantly alter tissue architecture, ECM content or organization (glycosaminoglycans, elastin, collagen, and laminin), observations of cell engraftment, or mechanical integrity of the tissue. Furthermore, these attributes of lung matrix did not change after 6 months in sterile buffer following sterilization with ScCO2, indicating that ScCO2 produces a matrix that is stable during storage. The current study's results indicate that ScCO2 can be used to sterilize acellular lung tissue while simultaneously preserving key biological components required for the function of the scaffold for regenerative medicine purposes.

  3. Radiation sterilization facility for melon fly

    International Nuclear Information System (INIS)

    Danno, A.

    1985-01-01

    The melon fly (Dacus cucurbitae Coquillett) has been observed in Amami Island since l975. Kagoshima Prefecture has had a melon fly eradication project underway since 1979. A mass-fearing facility and a radiation sterilization facility were constructed in Naze in March of l98l. In the early stages of the project, sterile insects were produced at the rate of 4 x l0/sup 6/ pupae/week. In the later stages, the activity of the project was enlarged by tenfold. The conditions for design of the radiation sterilization facility, which has been developed with a central control system for automated irradiation, are examined from an engineering standpoint

  4. Spore-Forming Bacteria that Resist Sterilization

    Science.gov (United States)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  5. Production of a sterile species: Quantum kinetics

    Science.gov (United States)

    Boyanovsky, D.; Ho, C. M.

    2007-10-01

    Production of a sterile species is studied within an effective model of active-sterile neutrino mixing in a medium in thermal equilibrium. The quantum kinetic equations for the distribution functions and coherences are obtained from two independent methods: the effective action and the quantum master equation. The decoherence time scale for active-sterile oscillations is τdec=2/Γaa, but the evolution of the distribution functions is determined by the two different time scales associated with the damping rates of the quasiparticle modes in the medium: Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where Γaa is the interaction rate of the active species in the absence of mixing and θm the mixing angle in the medium. These two time scales are widely different away from Mikheyev-Smirnov-Wolfenstein resonances and preclude the kinetic description of active-sterile production in terms of a simple rate equation. We give the complete set of quantum kinetic equations for the active and sterile populations and coherences and discuss in detail the various approximations. A generalization of the active-sterile transition probability in a medium is provided via the quantum master equation. We derive explicitly the usual quantum kinetic equations in terms of the “polarization vector” and show their equivalence to those obtained from the quantum master equation and effective action.

  6. Induction of male sterility in rice using chemical mutagens

    Energy Technology Data Exchange (ETDEWEB)

    Minocha, J L; Gupta, R K [Department of Genetics, Punjab Agricultural University, Ludhiana (India)

    1988-07-01

    Full text: To diversify the sources of cytoplasmic male sterility for hybrid seed production in rice (Oryza sativa L.) attempts were made to induce this character in a popular indica cultivar PR 106 through chemical mutagens. Seeds were treated with 0.4% ethidium bromide (EB) for 24 or 48h at 10 deg. C, with 0.4% ethyl methanesulphonate (EMS) for 24 or 48h at 10 deg. C for 16 hr at 20 deg. C or with 0.2% streptomycin sulphate (SM) for 24 or 48 hr at 10 deg. C. In M{sub 2} male sterile plants were detected in eleven different progenies, one from SM treatment and the remaining from EMS treatments. All the sterile plants had 100% non-stainable aborted pollen. Seed set upon open-pollination of the male sterile plants with the variety PR 106 ranged from 0.03 to 4.93 per cent whereas no seed formed in bagged panicles. In M{sub 3}, open-pollinated progenies of the male sterile plants and their fertile sibs were further studied. Two progenies segregated for male sterility, all others had only fertile plants. In one of the segregating progenies, five out of six and in the other nine out of fourteen plants were male sterile. The progenies of fertile sibs did not have any male sterile plant. The results indicate that sterility of cytoplasmic type has been induced by EMS. The parental variety PR 106 acts as the maintainer. (author)

  7. Induction of male sterility in rice using chemical mutagens

    International Nuclear Information System (INIS)

    Minocha, J.L.; Gupta, R.K.

    1988-01-01

    Full text: To diversify the sources of cytoplasmic male sterility for hybrid seed production in rice (Oryza sativa L.) attempts were made to induce this character in a popular indica cultivar PR 106 through chemical mutagens. Seeds were treated with 0.4% ethidium bromide (EB) for 24 or 48h at 10 deg. C, with 0.4% ethyl methanesulphonate (EMS) for 24 or 48h at 10 deg. C for 16 hr at 20 deg. C or with 0.2% streptomycin sulphate (SM) for 24 or 48 hr at 10 deg. C. In M 2 male sterile plants were detected in eleven different progenies, one from SM treatment and the remaining from EMS treatments. All the sterile plants had 100% non-stainable aborted pollen. Seed set upon open-pollination of the male sterile plants with the variety PR 106 ranged from 0.03 to 4.93 per cent whereas no seed formed in bagged panicles. In M 3 , open-pollinated progenies of the male sterile plants and their fertile sibs were further studied. Two progenies segregated for male sterility, all others had only fertile plants. In one of the segregating progenies, five out of six and in the other nine out of fourteen plants were male sterile. The progenies of fertile sibs did not have any male sterile plant. The results indicate that sterility of cytoplasmic type has been induced by EMS. The parental variety PR 106 acts as the maintainer. (author)

  8. Sterile insect supply, emergence, and release

    International Nuclear Information System (INIS)

    Dowell, R.V.; Worley, J.; Gomes, P.J.

    2005-01-01

    Insect mass-rearing for a sterile insect technique (SIT) programme is designed to move beyond the large-scale rearing of insects in a laboratory to the industrial production of consistently high-quality insects for sterilization and release. Each facility reflects the unique biology of the insect reared within it, but there are some generalities for all rearing facilities. Rearing insects in self-contained modules offers flexibility, and increased safety from catastrophic occurrences, compared with using a single building which houses all facets of the rearing process. Although mechanizing certain aspects of the rearing steps helps provide a consistently high-quality insect, successful mass-rearing and delivery depends largely upon the human component. Besides production in centralized facilities, insects can be produced from purchased eggs, or nowadays, adult insects are often obtained from specialized satellite emergence/collection facilities. Interest in commercializing insect production and release is increasing. Shipping sterile insects, sometimes over long distances, is now common practice. Procedures for handling and chilling adult insects, and providing food and water prior to release, are continually being improved. Sterile insects are released via static-release receptacles, ground-release systems, or most commonly from the air. The aerial release of chilled sterile insects is the most efficient method of release, especially when aircraft flight paths are guided by a Global Positioning System (GPS) linked to a computer-controlled release mechanism. (author)

  9. Sterilization and disinfection: the prevailing indifference

    International Nuclear Information System (INIS)

    Mirza, I.

    2007-01-01

    To evaluate the knowledge and attitude of health care professionals towards the process of sterilization and disinfection, and to check the adequacy of the reading material accessible to them. The study comprised of three components. In the first part, sections devoted to this subject in the popular books read by the students of operation theatre assistant course and students of diploma in general nursing were examined for adequacy and authenticity of information. In the second part, standard operating procedures were examined regarding sterilization of textile, rubber tubes of suction units and diathermy hand pieces of 20 operation theatres of three teaching hospital attached to undergraduate medical college of Punjab. In the third part of the study, working knowledge of 64 practicing operation theatre assistants and 57 practicing nurses was assessed through a questionnaire. It was found that popular books either did not contain the required information or the information provided was misleading or incorrect. Standard operating procedures for sterilization of selected items of all the operation theatres studied fell much below the standard of practice desired in the light of current knowledge and contemporary practices. Finally the working knowledge of the professionals studied was much below the bare minimum expected by the profession. There is a dire need for upgrading the knowledge and attitude of health care professionals regarding sterilization, besides improving the operation theatres sterilization procedures. (author)

  10. THE RATIONALE FOR THE USE OF TWO-PHASE SWITCHES FOR THREE-PHASE CONNECTIONS OF DISTRIBUTIVE DEVICE 27.5 KV

    Directory of Open Access Journals (Sweden)

    Yu. Ya. Sheika

    2008-12-01

    Full Text Available On the basis of materials of scientists of Moscow and Petersburg State Universities of C Ways and NIIEFAENERGO Ltd.» the author of this article with additions has considered a practical possibility of us bipolar switches on three-phase connections of distributive device 27,5 кV.

  11. Status of radiation sterilization of healthcare products in China

    International Nuclear Information System (INIS)

    Zhu Nankang; Wang Chunlei; Teng Weifang

    2004-01-01

    This paper describes the status of 60 Co radiation facilities both in service and under construction in China and examines the future market for radiation sterilization of healthcare products. Policies for developing the industry of radiation sterilization are also put forward; these include implementation of appropriate quality systems, scale-up and merging of existing radiation facilities, development of electron beam radiation for sterilization purposes and increasing awareness of the technology of radiation sterilization

  12. Sterilization processes. Meeting the demands of today's health care technology.

    Science.gov (United States)

    Crow, S

    1993-09-01

    Universal Precautions dictate sterilization for all invasive equipment that break the blood barrier; however, current methods of sterilization, such as steam and ethylene oxide gas (ETO), are not compatible with many of the delicate, heat-sensitive surgical instruments used in modern health care. In addition, traditional sterilization methods are often too time consuming for practical use in the operating room. Clearly, new sterilization processes need to be developed. In this article, the criteria modern sterilization processes must meet and how some manufacturers plan to meet this challenge are discussed. In addition, the pros and cons of using peracetic acid (the newest sterilization process currently available) are examined.

  13. Split ring containment attachment device

    International Nuclear Information System (INIS)

    Sammel, A.G.

    1996-01-01

    A containment attachment device is described for operatively connecting a glovebag to plastic sheeting covering hazardous material. The device includes an inner split ring member connected on one end to a middle ring member wherein the free end of the split ring member is inserted through a slit in the plastic sheeting to captively engage a generally circular portion of the plastic sheeting. A collar potion having an outer ring portion is provided with fastening means for securing the device together wherein the glovebag is operatively connected to the collar portion. 5 figs

  14. Control rod drive hydraulic device

    International Nuclear Information System (INIS)

    Takekawa, Toru.

    1994-01-01

    The device of the present invention can reliably prevent a possible erroneous withdrawal of control rod driving mechanism when the pressure of a coolant line is increased by isolation operation of hydraulic control units upon periodical inspection for a BWR type reactor. That is, a coolant line is connected to the downstream of a hydraulic supply device. The coolant line is connected to a hydraulic control unit. A coolant hydraulic detection device and a pressure setting device are disposed to the coolant line. A closing signal line and a returning signal line are disposed, which connect the hydraulic supply device and a flow rate control valve for the hydraulic setting device. In the device of the present invention, even if pressure of supplied coolants is elevated due to isolation of hydraulic control units, the elevation of the hydraulic pressure can be prevented. Accordingly, reliability upon periodical reactor inspection can be improved. Further, the facility is simplified and the installation to an existent facility is easy. (I.S.)

  15. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  16. Studies on the ecology of insects sterilized artificially (gamma radiation), 7

    International Nuclear Information System (INIS)

    Kiyoku, Masao; Tsukuda, Ritsuko

    1974-01-01

    Larvae of an oriental fruit fly line introduced, from Amami-Oshima island were reared using an artificial medium prepared with the base ingredient as corn-flour. When pupae were irradiated with a dose of 8 kR from the 137 Cs as gamma-rays source two days before emerging, both male and female adults emerged showed complete sterility. Percentage in emergence, however, was not significantly reduced. In an experiment that two hundred sterilized plus ten normal males were confined with ten normal females in a mating cage, the sterilized males were fully competitive with normal ones in mating to the normal females. Longevity of the sterilized adult males, however, tended to be slightly shorter than that of the normal ones when compared in the survival curves. When less than one hundred and fifty sterilized males were confined, however, few larvae were able to grow to adults. These progeny adult males and females showed the inherited sterility. When dose was 6 kR there was neither significant difference in the longevity between sterilized and normal adults, nor the complete sterility. Besides, the inherited sterility in offspring was not shown clearly. When more than two hundred sterilized plus ten normal males were combined with ten normal females, however, a considerable sterility was found. Causes of the sterility were investigated by dissection of the testes and spermathecae in females mated with 8 kR-sterilized males. (author)

  17. Current Sterilization Protocols-An Orthodontic Perspective

    Directory of Open Access Journals (Sweden)

    Abraham Vinod Korath

    2010-01-01

    Part I of this article focuses on the working principles of various methods of sterilization with an appraisalof their effects on orthodontic instruments. Additionally,contributory factors of instrument damage is enumerated to emphasis the importance of adhering to precise protocols and manufacturer recommendations as well as in alleviating some misconceptions about sterilization induced instrument damage.

  18. Applying the sterile insect technique to the control of insect pests

    International Nuclear Information System (INIS)

    LaChance, L.E.; Klassen, W.

    1991-01-01

    The sterile insect technique involves the mass-rearing of insects, which are sterilized by gamma rays from a 60 Co source before being released in a controlled fashion into nature. Matings between the sterile insects released and native insects produce no progeny, and so if enough of these matings occur the pest population can be controlled or even eradicated. A modification of the technique, especially suitable for the suppression of the moths and butterflies, is called the F, or inherited sterility method. In this, lower radiation doses are used such that the released males are only partially sterile (30-60%) and the females are fully sterile. When released males mate with native females some progeny are produced, but they are completely sterile. Thus, full expression of the sterility is delayed by one generation. This article describes the use of the sterile insect technique in controlling the screwworm fly, the tsetse fly, the medfly, the pink bollworm and the melon fly, and of the F 1 sterility method in the eradication of local gypsy moth infestations. 18 refs, 5 figs, 1 tab

  19. Present studies on the radio-sterilized drugs

    International Nuclear Information System (INIS)

    Marciniec, B.; Dettlaff, K.

    2007-01-01

    Lecture presents present status of radiosterilization of drugs and medical materials as compared to other sterilization methods. Literature review is shown on degradation of different kinds of drugs sterilized upon action of the sterilising doses of radiation

  20. Dark matter relic abundance and light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi-Lei [Center for High Energy Physics,Peking University, Beijing 100871 (China); Zhu, Shou-hua [Center for High Energy Physics,Peking University, Beijing 100871 (China); Institute of Theoretical Physics & State Key Laboratory of Nuclear Physics and Technology,Peking University, Beijing 100871 (China); Collaborative Innovation Center of Quantum Matter,Beijing 100871 (China)

    2017-01-09

    In this paper, we calculate the relic abundance of the dark matter particles when they can annihilate into sterile neutrinos with the mass ≲100 GeV in a simple model. Unlike the usual standard calculations, the sterile neutrino may fall out of the thermal equilibrium with the thermal bath before the dark matter freezes out. In such a case, if the Yukawa coupling y{sub N} between the Higgs and the sterile neutrino is small, this process gives rise to a larger Ω{sub DM}h{sup 2} so we need a larger coupling between the dark matter and the sterile neutrino for a correct relic abundance.

  1. submitter Prospects of Sterile Neutrino Search with the FCC-ee

    CERN Document Server

    Bay Nielsen, Sissel

    A proposed future circular e + e − collider, the FCC-ee, is suggested to search for sterile neutrinos. The Neutrino Minimal Standard Model, νMSM, is a model of sterile neutrinos, that accommodates explanations for several phenomena of physics beyond the Standard Model. This thesis presents an overview of the theoretical motivation for νMSM, an outline of the experimental conditions at the FCC-ee, and a review of previous accelerator bounds for sterile neutrinos. Two studies of sterile neutrinos with masses at the electroweak scale are introduced, an analysis of long lived sterile neutrinos, and an analysis of short lived sterile neutrinos. Both analyses include background studies and sensitivity estimates for the FCC-ee detector. The study of long lived sterile neutrinos is based on a search for detectable displaced vertices with 1012 Z decays, obtaining a search reach on the mixing angle |θ| 2 as small as 10−11. The study of short lived sterile neutrinos is a Monte Carlo study with a cut-based analysi...

  2. Thermonuclear device

    International Nuclear Information System (INIS)

    Oosaki, Osamu; Masuda, Kenju.

    1980-01-01

    Purpose: To provide excellent electric properties and high reliability in a thermonuclear device by improving a current collecting board connected to a coil device. Constitution: A current collecting board element perforated with an opening for enserting a connecting terminal is sized to be inserted into a plating tank, and is surface treated in the plating tank. Only the current collecting board element preferably surface treated is picked up. A plurality of such current collecting board elements are connected and welded to form a large current collecting board. In this manner, the current collecting board having several m 2 to several ten order m 2 in area can be obtained as preferably surface treated at the connecting terminal hole. The current collecting board element can be determined in shape with the existing facility without increasing the size of a surface treating tank. (Kamimura, M.)

  3. Eugenics in the community: gendered professions and eugenic sterilization in Alberta, 1928-1972.

    Science.gov (United States)

    Samson, Amy

    2014-01-01

    Scholarship on Alberta's Sexual Sterilization Act (1928-1972) has focused on the high-level politics behind the legislation, its main administrative body, the Eugenics Board, and its legal legacy, overlooking the largely female-dominated professions that were responsible for operating the program outside of the provincial mental health institutions. This paper investigates the relationship between eugenics and the professions of teaching, public health nursing, and social work. It argues that the Canadian mental hygiene and eugenics movements, which were fundamentally connected, provided these professions with an opportunity to maintain and extend their professional authority.

  4. Dark radiation sterile neutrino candidates after Planck data

    Energy Technology Data Exchange (ETDEWEB)

    Valentino, Eleonora Di; Melchiorri, Alessandro [Physics Department and INFN, Università di Roma ' ' La Sapienza' ' , Ple Aldo Moro 2, 00185, Rome (Italy); Mena, Olga, E-mail: eleonora.divalentino@roma1.infn.it, E-mail: alessandro.melchiorri@roma1.infn.it, E-mail: omena@ific.uv.es [IFIC, Universidad de Valencia-CSIC, 46071, Valencia (Spain)

    2013-11-01

    Recent Cosmic Microwave Background (CMB) results from the Planck satellite, combined with previous CMB data and Hubble constant measurements from the Hubble Space Telescope, provide a constraint on the effective number of relativistic degrees of freedom 3.62{sup +0.50}{sub −0.48} at 95% CL. New Planck data provide a unique opportunity to place limits on models containing relativistic species at the decoupling epoch. We present here the bounds on sterile neutrino models combining Planck data with galaxy clustering information. Assuming N{sub eff} active plus sterile massive neutrino species, in the case of a Planck+WP+HighL+HST analysis we find m{sub ν,} {sub sterile}{sup eff} < 0.36 eV and 3.14 < N{sub eff} < 4.15 at 95% CL, while using Planck+WP+HighL data in combination with the full shape of the galaxy power spectrum from the Baryon Oscillation Spectroscopic Survey BOSS Data Relase 9 measurements, we find that 3.30 < N{sub eff} < 4.43 and m{sub ν,} {sub sterile}{sup eff} < 0.33 eV both at 95% CL with the three active neutrinos having the minimum mass allowed in the normal hierarchy scheme, i.e. ∑m{sub ν} ∼ 0.06 eV. These values compromise the viability of the (3+2) massive sterile neutrino models for the parameter region indicated by global fits of neutrino oscillation data. Within the (3+1) massive sterile neutrino scenario, we find m{sub ν,} {sub sterile}{sup eff} < 0.34 eV at 95% CL. While the existence of one extra sterile massive neutrino state is compatible with current oscillation data, the values for the sterile neutrino mass preferred by oscillation analyses are significantly higher than the current cosmological bound. We review as well the bounds on extended dark sectors with additional light species based on the latest Planck CMB observations.

  5. Radiation sterilization: an industrial process

    International Nuclear Information System (INIS)

    Ley, F.J.

    1975-01-01

    A new dimension has been added to the use of radiation in the medical field with the introduction of radiation as a sterilizing agent. Its use in diagnosis through radioactive tracers or X-rays and in therapy administered with the most sophisticated of electrical machines or radioisotope units, is familiar in the hospital world, being well established therein. In contrast, the application of radiation sterilization is in industry where the installation of large radiation sources is already commonplace in many countries. The beginnings in the early 1950's centered on the Van de Graaff machine and linear accelerators and the pioneering efforts of Ethicon Inc. here in the United States must be recognized. However, although sterilization with electron beams is still current practice in a number of plants, the use of gamma rays from cobalt-60 is preferred. The first steps in this direction were taken by the U.K.A.E.A. which, in common with similar organizations elsewhere, was attempting to exploit the tremendous potential for cobalt-60 production arising through the rapid construction of nuclear reactors. The first full-scale commercial gamma plant was commissioned in the U.K. in 1960. It reached a loading of 500,000 curies before its demolition after twelve years of operation. The process gained rapid acceptance within industry and approval by health authorities because it provided a ''cold'' sterilization method combining the property of lethal effect with penetration. Its immediate impact occurred in the introduction of disposable products making it possible, for example, to use heat-labile plastics and new packaging materials and package designs. Certainly, the technique has proved complementary to sterilization methods based on heat and to the use of chemical agents, in particular ethylene oxide gas

  6. Sterile Neutrinos in Cold Climates

    International Nuclear Information System (INIS)

    Jones, Benjamin J.P.

    2015-01-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin 2 2θ 24 ≤ 0.02 at m 2 ~ 0.3 eV 2 , and the LSND and MiniBooNE allowed regions are excluded at

  7. Superbugs on Duodenoscopes: the Challenge of Cleaning and Disinfection of Reusable Devices.

    Science.gov (United States)

    Humphries, Romney M; McDonnell, Gerald

    2015-10-01

    Inadequate flexible endoscope reprocessing has been associated with infection outbreaks, most recently caused by carbapenem-resistant Enterobacteriaceae. Lapses in essential device reprocessing steps such as cleaning, disinfection/sterilization, and storage have been reported, but some outbreaks have occurred despite claimed adherence to established guidelines. Recommended changes in these guidelines include the use of sterilization instead of high-level disinfection or the use of routine microbial culturing to monitor efficacy of reprocessing. This review describes the current standards for endoscope reprocessing, associated outbreaks, and the complexities associated with both microbiological culture and sterilization approaches to mitigating the risk of infection associated with endoscopy. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  8. Effects of sterile neutrino and extra-dimension on big bang nucleosynthesis

    Science.gov (United States)

    Jang, Dukjae; Kusakabe, Motohiko; Cheoun, Myung-Ki

    2018-04-01

    We study effects of the sterile neutrino in the five-dimensional universe on the big bang nucleosynthesis (BBN). Since the five-dimensional universe model leads to an additional term in the Friedmann equation and the energy density of the sterile neutrino increases the total energy density, this model can affect the primordial abundance via changing the cosmic expansion rate. The energy density of the sterile neutrino can be determined by a rate equation for production of the sterile neutrino. We show that not only the mixing angle and the mass of the sterile neutrino, but also a resonant effect in the oscillation between sterile and active neutrinos is important to determine a relic abundance of the sterile neutrino. In this study, we also investigate how the sterile neutrino in extra-dimensional model can affect the BBN, and constrain the parameters related to the above properties of the sterile neutrino by using the observational primordial abundances of light elements.

  9. Comparative transcript profiling of fertile and sterile flower buds from multiple-allele-inherited male sterility in Chinese cabbage (Brassica campestris L. ssp. pekinensis).

    Science.gov (United States)

    Zhou, Xue; Liu, Zhiyong; Ji, Ruiqin; Feng, Hui

    2017-10-01

    We studied the underlying causes of multiple-allele-inherited male sterility in Chinese cabbage (Brassica campestris L. ssp. pekinensis) by identifying differentially expressed genes (DEGs) related to pollen sterility between fertile and sterile flower buds. In this work, we verified the stages of sterility microscopically and then performed transcriptome analysis of mRNA isolated from fertile and sterile buds using Illumina HiSeq 2000 platform sequencing. Approximately 80% of ~229 million high-quality paired-end reads were uniquely mapped to the reference genome. In sterile buds, 699 genes were significantly up-regulated and 4096 genes were down-regulated. Among the DEGs, 28 pollen cell wall-related genes, 54 transcription factor genes, 45 phytohormone-related genes, 20 anther and pollen-related genes, 212 specifically expressed transcripts, and 417 DEGs located on linkage group A07 were identified. Six transcription factor genes BrAMS, BrMS1, BrbHLH089, BrbHLH091, BrAtMYB103, and BrANAC025 were identified as putative sterility-related genes. The weak auxin signal that is regulated by BrABP1 may be one of the key factors causing pollen sterility observed here. Moreover, several significantly enriched GO terms such as "cell wall organization or biogenesis" (GO:0071554), "intrinsic to membrane" (GO:0031224), "integral to membrane" (GO:0016021), "hydrolase activity, acting on ester bonds" (GO:0016788), and one significantly enriched pathway "starch and sucrose metabolism" (ath00500) were identified in this work. qRT-PCR, PCR, and in situ hybridization experiments validated our RNA-seq transcriptome analysis as accurate and reliable. This study will lay the foundation for elucidating the molecular mechanism(s) that underly sterility and provide valuable information for studying multiple-allele-inherited male sterility in the Chinese cabbage line 'AB01'.

  10. Overview of FACTS devices for wind power plants directly connected to the transmission network

    DEFF Research Database (Denmark)

    Adamczyk, Andrzej Grzegorz; Teodorescu, Remus; Rodriguez, Pedro

    2010-01-01

    Growing number of wind turbines is changing electricity generation profile all over the world. This brings challenges for power system operation, which was designed and developed around conventional power plants with directly coupled synchronous generators. In result, safety and stability...... of the electrical network with high wind energy penetration might be compromised. For this reason transmission system operators (TSO) impose more stringent connection requirements on the wind power plant (WPP) owners. On the other hand flexible AC transmission systems (FACTS) devices offer enhancement of grid...... research in FACTS applicability for WPPs is summarized. Examples of few existing FACTS applications for wind farms are given....

  11. Endovascular Repair of Thoracoabdominal and Arch Aneurysms in Patients with Connective Tissue Disease Using Branched and Fenestrated Devices.

    Science.gov (United States)

    Clough, Rachel E; Martin-Gonzalez, Teresa; Van Calster, Katrien; Hertault, Adrien; Spear, Rafaëlle; Azzaoui, Richard; Sobocinski, Jonathan; Haulon, Stéphan

    2017-10-01

    Prophylactic open surgery is the standard practice in patients with connective tissue and thoracoabdominal aortic aneurysm (TAAA) and aortic arch disease. Branched and fenestrated devices offer a less invasive alternative but there are concerns regarding the durability of the repair and the effect of the stent graft on the fragile aortic wall. The aim of this study is to evaluate mid-term outcomes of fenestrated and/or branched endografting in patients with connective tissue disease. All patients with connective tissue disease who underwent TAAA or arch aneurysm repair using a fenestrated and/or branched endograft in a single, high-volume center between 2004 and 2015 were included. Ruptured aneurysms and acute aortic dissections were excluded from this study, but not chronic aortic dissections. In total, 427 (403 pararenal and TAAAs, and 24 arch aneurysms) endovascular interventions were performed during the study period. Of these, 17 patients (4%) (16 TAAAs, 1 arch) had connective tissue disease. All patients were classified as unfit for open repair. The mean age was 51 ± 8 years. Thirteen patients with TAAA were treated with a fenestrated, 1 with a branched, and 2 with a combined fenestrated/branch device. A double inner branch device was used to treat the arch aneurysm. The technical success rate was 100% with no incidence of early mortality, spinal cord ischemia, stroke, or further dissection. Postoperative deterioration in renal function was seen in 3 patients (18.8%) and no hemodialysis was required. The mean follow-up was 3.4 years (0.3-7.4). Aneurysm sac shrinkage was seen in 35% of patients (6/17) and the sac diameter remained stable in 65% of patients (11/17). No sac or sealing zone enlargement was observed in any of the patients and there were no conversions to open repair. Reintervention was required in 1 patient at 2 years for bilateral renal artery occlusion (successful fibrinolysis). One type II endoleak (lumbar) is under surveillance and 1 type

  12. Privacy and the Connected Society

    DEFF Research Database (Denmark)

    Sørensen, Lene Tolstrup; Khajuria, Samant; Skouby, Knud Erik

    The Vision of the 5G enabled connected society is highly based on the evolution and implementation of Internet of Things. This involves, amongst others, a significant raise in devices, sensors and communication in pervasive interconnections as well as cooperation amongst devices and entities across...... the society. Enabling the vision of the connected society, researchers point in the direction of security and privacy as areas to challenge the vision. By use of the Internet of Things reference model as well as the vision of the connected society, this paper identifies privacy of the individual with respect...... to three selected areas: Shopping, connected cars and online gaming. The paper concludes that privacy is a complexity within the connected society vision and that thee is a need for more privacy use cases to shed light on the challenge....

  13. Sterile Neutrino Search with MINOS

    International Nuclear Information System (INIS)

    Devan, Alena V.

    2015-01-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm 2 . An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, Δm s 2 ~ 1 eV 2 . The results of the 2013 sterile neutrino search are presented here.

  14. Genetically conditioned male sterility

    International Nuclear Information System (INIS)

    Gottschalk, W.

    1976-01-01

    A survey is given of two different types of genetically controlled male sterility in higher plants. 'Functional' male sterility is due to the action of mutated genes causing a misdifferentiation of the growing points in different specific ways. Under the influence of the genes of this group either the stamens or the archespore tissues are not differentiated. In other mutants functionable male germ cells are produced but cannot be used for fertilizing the egg cells because the anthers remain closed or anthers and stigma become spatially separated from each other. Other genes of the group are responsible for the transformation of stamens into carpels, i.e. for a change of the hermaphrodite flower into a unisexually female one. A second type of male sterility is due to the action of ms genes influencing the course of micro-sporogenesis directly. They cause the breakdown of this process in a specific meiotic stage characteristic for each gene of the group. This breakdown is introduced by the degeneration of PMCs, microspores, or pollen grains preventing the production of male germ cells. The female sex organs remain uninfluenced. (author)

  15. Radiation sterilization of traditional medicine drugs in Vietnam

    International Nuclear Information System (INIS)

    Hang, N.D.; Canh, T.T.; Thuy, T.T.

    1995-01-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author)

  16. Radiation sterilization of traditional medicine drugs in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Hang, N.D.; Canh, T.T.; Thuy, T.T. [Nuclear Research Inst., Da Lat (Viet Nam)

    1995-10-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author).

  17. Digital communication device

    DEFF Research Database (Denmark)

    2005-01-01

    The invention concerns a digital communication device like a hearing aid or a headset. The hearing aid or headset has a power supply, a signal processing device, means for receiving a wireless signal and a receiver or loudspeaker, which produces an audio signal based on a modulated pulsed signal...... point is provided which is in electrical contact with the metal of the metal box and whereby this third connection point is connected to the electric circuitry of the communication device at a point having a stable and well defined electrical potential. In this way the electro-and magnetic radiation...

  18. Nuclear-Cytoplasmic male-sterility in diploid dandelions

    NARCIS (Netherlands)

    van der Hulst, R.G.M.; Meirmans, P.; van Tienderen, P.H.; Van Damme, J.M.M.

    2004-01-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for

  19. Nuclear-cytoplasmic male-sterility in diploid dandelions

    NARCIS (Netherlands)

    van der Hulst, R.G.M.; Meirmans, P.G.; van Tienderen, P.H.; van Damme, J.M.M.

    2004-01-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for male

  20. Radioactive gaseous waste processing device

    International Nuclear Information System (INIS)

    Murakami, Kazuo.

    1997-01-01

    In a radioactive gaseous waste processing device, a dehumidifier in which a lot of hollow thread membranes are bundled and assembled is disposed instead of a dehumidifying cooling device and a dehumidifying tower. The dehumidifier comprises a main body, a great number of hollow thread membranes incorporated in the main body, a pair of fixing members for bundling and fixing both ends of the hollow thread membranes, a pair of caps for allowing the fixing members to pass through and fixing them on both ends of the main body, an off gas flowing pipe connected to one of the caps, a gas exhaustion pipe connected to the other end of the cap and a moisture removing pipeline connected to the main body. A flowrate control valve is connected to the moisture removing pipeline, and the other end of the moisture removing pipeline is connected between a main condensator and an air extraction device. Then, cooling and freezing devices using freon are no more necessary, and since the device uses the vacuum of the main condensator as a driving source and does not use dynamic equipments, labors for the maintenance is greatly reduced to improve economical property. The facilities are reduced in the size thereby enabling to use space effectively. (N.H.)

  1. Induced mutant for male sterility in niger

    International Nuclear Information System (INIS)

    Sujatha, M.

    2001-01-01

    Full text: Niger (Guizotia abyssinica Cass.), an important oilseed crop of the family Compositae is highly cross-pollinated due to the twin mechanisms of protandry and incompatibility. Studies revealed the functional nature of protandry and the breakdown of incompatibility with alteration in temperature. It has very small flowers (disc florets) arranged in a capitulum that open on 3-4 consecutive days which pose problems in emasculation for cross-breeding. To induce mutations, seeds of variety 'IGP-76' were irradiated with γ-rays 200 to 1000 Gy. All seeds of M 1 plants were sown separately in individual plant-to progeny rows. The results of screening of M 2 segregating material indicated that γ-ray treatment was effective in induction of male sterility. Frequency of visible mutations were higher in sibbed progeny as compared to open pollinated population and male sterile plants were observed only in sibbed population (1000 Gy). Male sterile plants could easily be identified at the flowering stage by their altered floral morphology (disc florets transformed into ligulate ray florets) and complete absence or presence of a rudimentary anther column. Seeds were collected following sib-mating with the fertile counterparts. Progeny segregated in a ration of 3 normal : 1 male sterile. Further work on the mechanism of sterility, maintenance and linkage relationships with associated characters is under progress. This is the first report of induction of male sterility in niger through the use of physical mutagens. The availability of this mutant will be of great value for exploitation of heterosis on commercial basis. (author)

  2. Evaluation of steam sterilization conditions for [{sup 18}F]fludeoxyglucose

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Priscilla F.; Nascimento, Leonardo T.; Valente, Eduardo S.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z., E-mail: somafe@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Unidade de Pesquisa e Producao de Radiofarmacos

    2011-07-01

    [{sup 18}F]Flu deoxyglucose ({sup 18}FDG) is the most commonly used radiopharmaceutical for positron emission tomography. Sterile filtration of the final product into sterile vials using 0.22 {mu}m filter membrane is usually adopted for {sup 18}FDG. However, Good Manufacturing Practice (GMP) guidelines recommend heat sterilization as the method of choice to ensure sterility of pharmaceutical preparations. The aim of this study was to essay different steam sterilization conditions in order to choose the best one for {sup 18}FDG. Three different sterilization conditions were essayed. The first one at 121 deg C for 15 minutes, the second one at 135 deg C for 3.5 minutes and the third one at 133 deg C for 2 minutes. {sup 18}FDG pH-formulation was kept around 6.0. At the end of autoclave cycles, {sup 18}FDG sterility was evaluated by direct inoculation of {sup 18}FDG in culture media and radiochemical purity was determined by TLC and HPLC. Results demonstrated that all essayed conditions were able to ensure {sup 18}FDG sterility, but caused a decrease in radiochemical purity of {sup 18}FDG. Autoclave cycle at 133 deg C for 2 minutes was the best essayed condition for {sup 18}FDG terminal sterilization, once it provided the greater radiochemical purity value and took less time. {sup 18}FDG was able to meet specifications after autoclave cycles, what supports the application of steam sterilization in routine {sup 18}FDG production, in compliance with GMP. (author)

  3. End-preparation assessments and tests for compounded sterile preparations.

    Science.gov (United States)

    McElhiney, Linda F

    2013-01-01

    Outsourcing has become a necessity to obtain sterile products that are currently on backorder. Because of the expense of outsourcing sterile compounding, pharmacy leadership in health systems are now considering the option of insourcing and batch preparing compounded sterile preparations, which can be a viable option for a health system. It can significantly decrease drug-spending costs, and the pharmacy has a complete record of the compounding process. The key to preparing high-quality, safe, sterile preparations and meeting United States Pharmacopeia standards is end-preparation assessments and tests.

  4. Protozoa and their bacterial prey colonize sterile soil fast

    DEFF Research Database (Denmark)

    Altenburger, Andreas; Ekelund, Flemming; Jacobsen, Carsten Suhr

    2010-01-01

    We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them to the at......We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them...

  5. Hybrid male sterility and genome-wide misexpression of male reproductive proteases.

    Science.gov (United States)

    Gomes, Suzanne; Civetta, Alberto

    2015-07-06

    Hybrid male sterility is a common barrier to gene flow between species. Previous studies have posited a link between misregulation of spermatogenesis genes in interspecies hybrids and sterility. However, in the absence of fully fertile control hybrids, it is impossible to differentiate between misregulation associated with sterility vs. fast male gene regulatory evolution. Here, we differentiate between these two possibilities using a D. pseudoobscura species pair that experiences unidirectional hybrid sterility. We identify genes uniquely misexpressed in sterile hybrid male reproductive tracts via RNA-seq. The sterile male hybrids had more misregulated and more over or under expressed genes relative to parental species than the fertile male hybrids. Proteases were the only gene ontology class overrepresented among uniquely misexpressed genes, with four located within a previously identified hybrid male sterility locus. This result highlights the potential role of a previously unexplored class of genes in interspecific hybrid male sterility and speciation.

  6. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    PRINCIPLES OF HEAT STERILIZATION. IN DENTAL PRACTICE. W.H. van Palenstein Helderman. Department of Community and Preventive Dentistry,. Faculty of Dentistry, Muhimbili University College of Health Sciences,. Dar es Salaam, Tanzania. Introduction. Sterilization is defined as the destruction of all forms of life ...

  7. Thermal design of an irradiation device with cobalt

    International Nuclear Information System (INIS)

    Parkansky, David; Halpert, Silvia G.; Vazquez, Luis A.

    1999-01-01

    The thermal behavior of a device to transport 60 Co rods has been calculated. The device has been designed to be also used to radio sterilize medical supplies and hospital wastes. The calculations show that, in normal conditions, the maximum temperature of the external surface of the device is 55 C and that of the shielding lead is 110 C. In fire conditions, without taking into account the radiation of heath to or from the combustion gases, the lead does not reach the melting point. If the gases are taken into account, only 6.3 % of the lead is melted down. The transport-irradiation device complies with the IAEA recommendations on the safe transport of radioactive material

  8. The effects of sterilization on the tensile strength of orthodontic wires.

    Science.gov (United States)

    Staggers, J A; Margeson, D

    1993-01-01

    The purpose of this study was to evaluate the effect of sterilization on the tensile strength of 0.016" beta-titanium, nickel titanium and stainless steel wires. Three common methods of sterilization--autoclaving, dry heat and ethylene oxide--were evaluated in three test trials involving zero, one and five sterilization cycles. For each of the test trials, five pieces each of 0.016" TMA, 0.016" Sentalloy and 0.016" Tru-chrome stainless steel wires were sterilized using a standard autoclave. Five other pieces of each of the same wires were sterilized in a dryclave, while an additional five pieces of each of the three wire types were sterilized using ethylene oxide. The ultimate tensile strengths of the wires were then determined using an Instron Universal Testing Machine. The data were compared for statistical differences using analysis of variance. The results showed that dry heat sterilization significantly increased the tensile strength of TMA wires after one cycle, but not after five cycles. Autoclaving and ethylene oxide sterilization did not significantly alter the tensile strength of TMA wires. Dry heat and autoclave sterilization also significantly increased the tensile strength of Sentalloy wires, but the mean strength after five sterilization cycles was not significantly different than after one cycle. Ethylene oxide sterilization of Sentalloy wires did not significantly alter the tensile strengths of that wire. There were no significant differences in the tensile strengths of the stainless steel wires following zero, one or five cycles for any of the sterilization methods.

  9. Gamma ray induced male sterility mutant in lentil

    International Nuclear Information System (INIS)

    Srivastava, A.; Yadav, A.K.

    2001-01-01

    Full text: Male sterility refers to the failure of pollen grains to bring about effective fertilization, either due to structural default or physiological disfunctioning and has special significance in hybridization programmes. Male steriles have been produced in a number of crop plants like red gram, pigeon pea, mung bean, khesari and lentil. A completely male sterile mutant was isolated in Lens culinaris Medik, after seed treatment with 100 Gy dose of gamma rays. The male sterile mutant showed 100% pollen sterility but was morphologically more vigorous than the parent plants. It showed more branches and its leaves were bigger, more oblong and dark green. The number of flowers borne by the mutant was significantly higher than any other plant of the treatment. The size of the flowers was also increased but the anthers were smaller in size. Pollen grains were few in number, round in shape but empty and did not take up any stain, indicating that normal microsporogenesis had not taken place. This male sterile mutant was used as the female parent and pollinated with pollen of a parent. Four pods with one seed in each were formed indicating that the mutant was female fertile. The seeds were smaller than those of the parent variety and also dark coloured. The mutant showed increased vigour and flower number as compared to parental plants. Lentil is an important pulse crop and induction of variability in its germplasm is necessary for its improvement. Male steriles can be used conveniently in lentil hybridization programmes. (author)

  10. Impact of moth suppression/eradication programmes using the sterile insect technique or inherited sterility

    International Nuclear Information System (INIS)

    Bloem, K.A.; Bloem, S.; Carpenter, J.E.

    2005-01-01

    Numerous lepidopteran species have been investigated as candidates for control using the sterile insect technique (SIT) or inherited sterility (IS). However to date only two programmes are operational - the pink bollworm containment programme in the San Joaquin Valley, California, USA, and the codling moth suppression programme in British Columbia, Canada. Both of these programmes have been highly successful in controlling the pest populations, reducing insecticide use, and improving interactions between growers and the general public. However, other benefits, including the positive economic impacts of these programmes, have not been fully quantified. Methods to reduce the cost of lepidopteran programmes might include combining the SIT/IS with other pest control tactics such as mating disruption or the release of natural enemies, the development of genetic sexing strains, or the application of molecular technologies to develop genetic markers and genetic sterility. In future the greatest potential for impact of lepidopteran SIT/IS programmes may be in combating key invasive threats such as the eradication of an outbreak of the painted apple moth in New Zealand. (author)

  11. Development of the microbiological control aspects of radiation sterilization of medical supplies. Part of a coordinated programme on radiation sterilization of medical and biological products

    International Nuclear Information System (INIS)

    Horakova, V.

    1978-06-01

    The variability and extent of microbial contamination of such medical supplies as hydrophilic gauze swabs and dermo-epidermal grafts were investigated. Gross bacterial contamination was observed in the swabs, with a relative absence of water. It was concluded that medical disposable products under dried aerobic conditions can be sterilized by a minimum dose of 25 kJ/kg/2.5 Mrad if the mean value of pre-sterilization bacterial counts does not exceed 100. Products contaminated by 10,000 or more bacteria prior to sterilization must be considered ''decontaminated'' after irradiation but as rather than ''sterile'', as accepted pharmaceutically. The author recommends that the efficacy of the sterilization dose used be evaluated, assuming the decrease in contaminated items to follow the exponential law, with constants estimated as n=1.98 and k=0.44, and that the sterilization process to be controlled dosimetrically. In general, sub-process doses should be used before actual sterilization by ionizing radiation, in order to estimate the constants characterizing the decrease in contamination under given conditions. In skin grafts a dose of 25 kJ/kg was found to give a high guarantee of sterility. A minimum sterilizing dose of 20 kJ/kg was recommended, provided the mean value of microorganisms on 1 cm 2 of the disinfected and freeze-dried skin grafts from human cadavres was 100, without exceeding an upper limit of 130

  12. Sterilization techniques without heating (ultraviolet ray, radiation and ozone)

    International Nuclear Information System (INIS)

    Ito, Hitoshi

    1991-01-01

    The recent demand of consumers for processed foods is characterized by the intention for health and nature, besides, the demand for low sweetness, salt reduction, no additive and freshness becomes strong. In view of the control of microorganisms in products, all these become the negative factors. Accordingly, in order to overcome them, it is urgently desired to develop new technology or to improve conventional methods. As to heating sterilization, the uniform temperature treatment to the inside of foods is difficult, and it cannot be applied to perishables. The high temperature sterilization above 120degC causes the change in nutrition composition and physical properties. Ultraviolet ray and ozone can be used for the sterilization of food surface and powder and liquid foods. Radiation treatment can be applied to packed foods and frozen foods as well as food surface. The principle and the fields of application of ultraviolet ray sterilization, radiation sterilization and ozone sterilization are reported. In the mechanism of these methods, the action to DNA and oxidation are common. (K.I.)

  13. Sterile Neutrino Search in the NOvA Far Detector

    Energy Technology Data Exchange (ETDEWEB)

    Edayath, Sijith [Cochin U.; Aurisano, Adam [Cincinnati U.; Sousa, Alexandre [Cincinnati U.; Davies, Gavin [Indiana U.; Suter, Louise [Fermilab; Yang, Shaokai [Cincinnati U.

    2017-10-03

    The majority of neutrino oscillation experiments have obtained evidence for neutrino oscillations that are compatible with the three-flavor model. Explaining anomalous results from short-baseline experiments, such as LSND and MiniBooNE, in terms of neutrino oscillations requires the existence of sterile neutrinos. The search for sterile neutrino mixing conducted in NOvA uses a long baseline of 810 km between Near Detector (ND) at Fermilab and Far Detector (FD) in Minnesota. The signal for sterile neutrino oscillations is a deficit of neutral-current neutrino interactions at the FD with respect to the ND prediction. In this document, We will present the analysis improvements that we are implementing for future NC sterile neutrino searches with NOvA. These include: improved modelling of our detector response; the inclusion of NC 2p2h interaction modelling; implementing a better energy reconstruction techniques; and including possible oscillation due to sterile neutrinos in the ND . This improvements enable us to do a simultaneous ND-FD shape fit of the NC energy spectrum covering a wider sterile mass range than previous analyses.

  14. 42 CFR 50.207 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207...

  15. [Characteristics and follow-up of sterilized women].

    Science.gov (United States)

    Molina, R; López, I

    1982-02-01

    In order to gain insight into the characteristics of sterilized women evaluating at the same time the effects of sterilization, 70 patients who underwent sterilization in an Obstetrics Unit were studied. The clinical records were analyzed and a questionnaire comprising general knowledge, attitudes, and conduct was applied. Women over 30 and with a parity of 4 or more predominated. There was a low frequency of abortions reported but this information is not reliable. The educational level was lower than the average for the Metropolitan Region and pointed to a more precocious initiation in sexual relationships than was found in a previous similar study. Religion proved to be no obstacle for sterilization nor was attendance to church subsequently diminished. A negative moral feeling towards the operation nearly disappeared following surgery. The fear of sexual dissatisfaction in husbands decreased following surgery and a similar effect was seen with regard to negative self-image. There were no changes in marital relations nor in their satisfaction. (author's modified)

  16. Reliability of Laparoscopic Compared With Hysteroscopic Sterilization at One Year: A Decision Analysis

    Science.gov (United States)

    Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.

    2011-01-01

    OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842

  17. Whole Mitochondrial Genome Sequencing and Re-Examination of a Cytoplasmic Male Sterility-Associated Gene in Boro-Taichung-Type Cytoplasmic Male Sterile Rice.

    Science.gov (United States)

    Kazama, Tomohiko; Toriyama, Kinya

    2016-01-01

    Nuclear genome substitutions between subspecies can lead to cytoplasmic male sterility (CMS) through incompatibility between nuclear and mitochondrial genomes. Boro-Taichung (BT)-type CMS rice was obtained by substituting the nuclear genome of Oryza sativa subsp. indica cultivar Chinsurah Boro II with that of Oryza sativa subsp. japonica cultivar Taichung 65. In BT-type CMS rice, the mitochondrial gene orf79 is associated with male sterility. A complete sequence of the Boro-type mitochondrial genome responsible for BT-type CMS has not been determined to date. Here, we used pyrosequencing to construct the Boro-type mitochondrial genome. The contiguous sequences were assembled into five circular DNA molecules, four of which could be connected into a single circle. The two resulting subgenomic circles were unable to form a reliable master circle, as recombination between them was scarcely detected. We also found an unequal abundance of DNA molecules for the two loci of atp6. These results indicate the presence of multi-partite DNA molecules in the Boro-type mitochondrial genome. Expression patterns were investigated for Boro-type mitochondria-specific orfs, which were not found in the mitochondria from the standard japonica cultivar Nipponbare. Restorer of fertility 1 (RF1)-dependent RNA processing has been observed in orf79-containing RNA but was not detected in other Boro-type mitochondria-specific orfs, supporting the conclusion that orf79 is a unique CMS-associated gene in Boro-type mitochondria.

  18. Sterile Neutrino Search with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Devan, Alena V. [College of William and Mary, Williamsburg, VA (United States)

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  19. Cytotoxicity of Pd nanostructures supported on PEN: Influence of sterilization on Pd/PEN interface

    Energy Technology Data Exchange (ETDEWEB)

    Polívková, M., E-mail: polivkoa@vscht.cz [Department of Solid State Engineering, University of Chemistry and Technology Prague, 166 28 Prague (Czech Republic); Siegel, J. [Department of Solid State Engineering, University of Chemistry and Technology Prague, 166 28 Prague (Czech Republic); Rimpelová, S. [Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, 166 28 Prague (Czech Republic); Hubáček, T. [Institute of Hydrobiology, Biology Centre of the AS CR, 370 05 Ceske Budejovice (Czech Republic); Kolská, Z. [Materials Centre of Usti n. L., J.E. Purkyne University, 400 96 Usti nad Labem (Czech Republic); Švorčík, V. [Department of Solid State Engineering, University of Chemistry and Technology Prague, 166 28 Prague (Czech Republic)

    2017-01-01

    Non-conventional antimicrobial agents, such as palladium nanostructures, have been increasingly used in the medicinal technology. However, experiences uncovering their harmful and damaging effects to human health have begun to appear. In this study, we have focused on in vitro cytotoxicity assessment of Pd nanostructures supported on a biocompatible polymer. Pd nanolayers of variable thicknesses (ranging from 1.1 to 22.4 nm) were sputtered on polyethylene naphthalate (PEN). These nanolayers were transformed by low-temperature post-deposition annealing into discrete nanoislands. Samples were characterized by AFM, XPS, ICP-MS and electrokinetic analysis before and after annealing. Sterilization of samples prior to cytotoxicity testing was done by UV irradiation, autoclave and/or ethanol. Among the listed sterilization techniques, we have chosen the gentlest one which had minimal impact on sample morphology, Pd dissolution and overall Pd/PEN interface quality. Cytotoxic response of Pd nanostructures was determined by WST-1 cell viability assay in vitro using three model cell lines: mouse macrophages (RAW 264.7) and two types of mouse embryonic fibroblasts (L929 and NIH 3T3). Finally, cell morphology in response to Pd/PEN was evaluated by means of fluorescence microscopy. - Highlights: • Annealing of Pd nanolayers on PEN resulted to Pd aggregation and formation of discrete nanoislands. • UV treatment was found as the gentlest sterilization method in term of physicochemical properties of Pd/PEN interface. • Autoclaving and chemical sterilization by ethanol resulted into remarkable changes of Pd/PEN interface. • Cytotoxicity of Pd samples was insignificant. • Pd nanostructures are potentially applicable as health-unobjectionable antibacterial coatings of medical devices.

  20. Study on the role of active radicals on plasma sterilization inside small diameter flexible polymeric tubes

    Science.gov (United States)

    Mstsuura, Hiroto; Fujiyama, Takatomo; Okuno, Yasuki; Furuta, Masakazu; Okuda, Shuichi; Takemura, Yuichiro

    2015-09-01

    Recently, atmospheric pressure discharge plasma has gathered attention in various fields. Among them, plasma sterilization with many types of plasma source has studied for decades and its mechanism is still an open question. If active radicals produced in plasma has main contribution of killing bacterias, direct contact of the so-called plasma flame might not be necessary. To confirm this, sterilization inside small diameter flexible polymeric tubes is studied in present work. DBD type plasma jet is produce by flowing helium gas in a glass tube. A long polymeric tube is connected and plasma jet is introduced into it. Plasma flame length depends on helium gas flow rate, but limited to about 10 cm in our experimental condition. E.colis set at the exit plasma source is easily killed during 10 min irradiation. At the tube end (about 20 cm away from plasma source exit), sterilization is possible with 30 min operation. This result shows that active radical is produced with helium plasma and mist contained in sample, and it can be transferred more than 20 cm during it life time. More plasma diagnostic data will also be shown at the conference. This work was partially supported by the ''ZE Research Program, IAE(ZE27B-4).

  1. Is parotid saliva sterile on entry to the oral cavity?

    DEFF Research Database (Denmark)

    Schrøder, Stine A; Bardow, Allan; Eickhardt-Dalbøge, Steffen

    2017-01-01

    CONCLUSION: The present study indicates that parotid saliva is sterile on entry to the oral cavity. OBJECTIVES: The objective was to investigate if parotid saliva is sterile on entry to the oral cavity and, thus, prior to contamination by oral bacteria. METHOD: Forty healthy volunteers were...... included in sterile parotid saliva collection. Parotid saliva was collected using a sterile Lashley cup, placed over the papilla of the Stensen´s duct, as well as sterile tubes and syringes for collection. All collections were followed by collection of a positive control sample where some of the sterile...... obtained parotid saliva had been exposed to the contralateral mucosal membranes. All samples parotid saliva, as well as the positive controls, were cultivated, and 10 randomly selected parotid saliva samples underwent polymerase chain reaction (PCR) analyses. RESULTS: In 33 of 40 parotid saliva samples...

  2. Reason behind wet pack after steam sterilization and its consequences: An overview from Central Sterile Supply Department of a cancer center in eastern India.

    Science.gov (United States)

    Basu, Debabrata

    Wet pack after steam sterilization process that means there are surely obtain millions of microorganisms that can breed and multiply rapidly and objects are unsterile and can never be used for further procedure. There are many reasons behind the wet pack occurrences after autoclaving like poor quality of wrapping materials, faulty valves of rigid container, faulty loading and packaging technique, poor steam quality, sterilizer malfunction and may be design related problems in CSSD sterile storage area. Cause of wet pack after steam sterilization processes may occur severe problems because of wasted time and effort, increased work load, increased cost, potentially contaminated instruments, infection risk to the patient, poor patient outcomes and delayed or cancellation of procedures. But such wet pack scenario can be avoided by various methods by using good steam (water) quality, performing periodic maintenance of the Autoclaves, avoidance of sterilizer overloading, allowing adequate post sterilization time to cool down the materials to room temperature, using good quality wrapping materials, properly maintain temperature and humidity of sterile storage area etc. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  3. Assessment of Non-Sterile Pharmaceutical Compounding Practices ...

    African Journals Online (AJOL)

    A descriptive cross-sectional survey was conducted to assess the practices of non-sterile pharmaceutical compounding in selected 42 community and 3 hospital pharmacies in Addis Ababa, Ethiopia from 01 April, 2016 to 15 May, 2016. The study revealed that the most commonly prescribed and compounded non-sterile ...

  4. Sodium hypochlorite sterilization of culture medium in ...

    African Journals Online (AJOL)

    With the purpose of finding an alternative to thermal sterilization, this research aimed at assessing the efficiency and ideal concentration of sodium hypochlorite for sterilization of culture media and glassware used during rooting of micropropagated Gerbera hybrida cv. Essandre. Two experiments were carried out. In the first ...

  5. Genetic expression of induced rice sterility under alien-cytoplasm

    International Nuclear Information System (INIS)

    Wang Naiyuan; Cai Zhijun; Liang Kangjing; Li Yu

    2005-01-01

    Rice restorer lines were treated with 60 Co γ-ray and 4 male sterile mutants obtained with the fertility of controlled by 4 non-allelic recessive genes, respectively. Sixty combinations were made by using male sterile plants/fertile plants as male parents, and 15 different cytoplasmic substitution lines of the same cell nucleus as female parents. The result showed that F 1 spikelets were normal and fertile, and different numbers of male sterile plants were segregated in F 2 . Complete fertility genotype was not found among interactions between induced male sterile genes and alien-cytoplasms. (authors)

  6. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Raquel Galante

    Full Text Available In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation, a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP hydrogel nanoparticles (CS-HNP, with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol. Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  7. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Science.gov (United States)

    Galante, Raquel; Rediguieri, Carolina F; Kikuchi, Irene Satiko; Vasquez, Pablo A S; Colaço, Rogério; Serro, Ana Paula; Pinto, Terezinha J A

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  8. Microbiological method for radiation sterilization (I). General knowledge and handling technique for bacterial identification

    International Nuclear Information System (INIS)

    Koshikawa, Tomihiko

    2004-01-01

    The part I in this title series describes the basic knowledge and technique for identification of bacteria in the radiation sterilization of medical devices, where the radiation dose can be decided from the number and radio-resistance of the bioburden (bacteria on the device). Four essential, actual technologies for identification are described: isolation and storage of bacteria; decision of bacterial natures, involving 3 Gram staining methods, morphology by microscopy and/or phase-contrast microscopy, spore-forming bacteria, and size measurement by micrometry; Other test items for identification of genus, involving motility, oxygen demand, catalase, oxidase, acid production from glucose, and OF (oxidation or fermentation for glucose degradation) test; and colony observation. Media, identification kits and record forms for these are presented. (N.I.)

  9. Radiation detection device

    International Nuclear Information System (INIS)

    Peschmann, Kristian.

    1982-01-01

    A radiation detector suitable for use in computer tomography device has an ionization chamber which comprises a high voltage electrode, a collector electrode, a high voltage source having two terminals, one connected to the high voltage electrode, current measuring means having two terminals, one connected to the high voltage source and the other to the collector electrode, and an auxilliary electrode near and parallel to the entrance window of the device, having one adjacent to the high voltage electrode and the other adjacent but not connected to the collector electrode. The auxilliary electrode is connected to the high voltage source. In this way the electric field between the high voltage and collector electrodes is made homogeneous in the vicinity of the auxilliary electrode, improving the measuring speed of the detector

  10. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  11. Sterile Neutrinos in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Benjamin J.P. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  12. A versatile nanotechnology to connect individual nano-objects for the fabrication of hybrid single-electron devices

    International Nuclear Information System (INIS)

    Bernand-Mantel, A; Bouzehouane, K; Seneor, P; Fusil, S; Deranlot, C; Petroff, F; Fert, A; Brenac, A; Notin, L; Morel, R

    2010-01-01

    We report on the high yield connection of single nano-objects as small as a few nanometres in diameter to separately elaborated metallic electrodes, using a 'table-top' nanotechnology. Single-electron transport measurements validate that transport occurs through a single nano-object. The vertical geometry of the device natively allows an independent choice of materials for each electrode and the nano-object. In addition ferromagnetic materials can be used without encountering oxidation problems. The possibility of elaborating such hybrid nanodevices opens new routes for the democratization of spintronic studies in low dimensions.

  13. Estimation of populations and sterility induction in Anastrepha ludens (Diptera: Tephritidae) fruit flies

    International Nuclear Information System (INIS)

    Flores, Salvador; Montoya, Pablo; Toledo, Jorge; Liedo, Pablo; Enkerlin, Walther

    2015-01-01

    The relationship between different release densities of sterile flies and fly trap captures, expressed as flies per trap per day, in the monitoring of Anastrepha ludens (Loew) populations was evaluated in mango orchards. The induction of sterility in fertile females was evaluated using different ratios of sterile: fertile males under field cage conditions. A direct relationship between recaptured flies and densities of release sterile flies was found. However, trap efficiency, expressed as percentage of recaptured flies, decreased as the density of released flies increased. Sterility induction was positively correlated to the ratio of sterile: fertile flies. A significant difference in egg fertility among treatments was observed. The trajectory of sterility induction slowed down after a sterile: wild ratio of 30:1, which suggests that this ratio could be appropriate in an sterile insect technique program with A. ludens. Sterility induction was greater when only sterile males were released than when releasing both sterile males and females, but the differences were not significant. Our findings contribute to a better interpretation of fly captures obtained from the field trapping networks, and to an improvement in the efficiency of sterile insect technique against A. ludens fruit flies, through the implementation of more rational sterile fly release densities. (author)

  14. Delay reduction in multi-hop device-to-device communication using network coding

    KAUST Repository

    Douik, Ahmed S.

    2015-08-12

    This paper considers the problem of reducing the broadcast delay of wireless networks using instantly decodable network coding (IDNC) based device-to-device (D2D) communications. In D2D-enabled networks, devices help hasten the recovery of the lost packets of devices in their transmission range by sending network coded packets. To solve the problem, the different events occurring at each device are identified so as to derive an expression for the probability distribution of the decoding delay. The joint optimization problem over the set of transmitting devices and the packet combinations of each is formulated. Due to the high complexity of finding the optimal solution, this paper focuses on cooperation without interference between the transmitting users. The optimal solution, in such interference-less scenario, is expressed using a graph theory approach by introducing the cooperation graph. Extensive simulations compare the decoding delay experienced in the Point to Multi-Point (PMP), the fully connected D2D (FC-D2D) and the more practical partially connected D2D (PC-D2D) configurations and suggest that the PC-D2D outperforms the FC-D2D in all situations and provides an enormous gain for poorly connected networks.

  15. Sterilization of Biofilm on a Titanium Surface Using a Combination of Nonthermal Plasma and Chlorhexidine Digluconate

    Directory of Open Access Journals (Sweden)

    Tripti Thapa Gupta

    2017-01-01

    Full Text Available Nosocomial infections caused by opportunistic bacteria pose major healthcare problem worldwide. Out of the many microorganisms responsible for such infections, Pseudomonas aeruginosa is a ubiquitous bacterium that accounts for 10–20% of hospital-acquired infections. These infections have mortality rates ranging from 18 to 60% and the cost of treatment ranges from $20,000 to $80,000 per infection. The formation of biofilms on medical devices and implants is responsible for the majority of those infections. Only limited progress has been made to prevent this issue in a safe and cost-effective manner. To address this, we propose employing jet plasma to break down and inactivate biofilms in vitro. Moreover, to improve the antimicrobial effect on the biofilm, a treatment method using a combination of jet plasma and a biocide known as chlorhexidine (CHX digluconate was investigated. We found that complete sterilization of P. aeruginosa biofilms can be achieved after combinatorial treatment using plasma and CHX. A decrease in biofilm viability was also observed using confocal laser scanning electron microscopy (CLSM. This treatment method sterilized biofilm-contaminated surfaces in a short treatment time, indicating it to be a potential tool for the removal of biofilms present on medical devices and implants.

  16. Radiating sterilization of fruits of the barberry ordinary berberis vulgaris L

    International Nuclear Information System (INIS)

    Abilova, I.E.

    2006-01-01

    Full text: The riches of flora of Azerbaijan with its specific saturation represent a huge raw-material base for a farmaceutical industry. In territory of republic 3 kinds of a barberry wildly grow, a perspective kind is the barberry ordinary Berberis vulgaris L.In the medical purposes leaves, a root, stalks and fruits of a barberry are applied. Berries as water tincture are applied at rheumatism, a malaria, a diabetes [I.A.Damirov and etn-tilde 1988; Hofbauer F., Askeril M, 2002, etc.], at diseases of a gastroenteric path, easy, at diseases of a mouth [Ikram M, 1975]. Biochemical processes in the collected raw material during first time proceed, as in an alive plant, that is synthesis of biologi-cally active substances prevails. On a measure natural losing water in connection with the termination of receipt of a moisture and nutrients, processes of an exchange are shifted aside disintegration that results in decrease of biologically active substances in vegetative raw material. However in some cases the processes proceeding in drying raw material result on the contrary, in increase in the maintenance of working substances. Therefore improvement of ways of drying and processing of medicinal raw material by influence of small dozes ? - radiations c the purpose of reception of the high-quality raw material, connected with growing need of a global farmaceutical industry for herbs and phitopreparats is an actual problem. As a result of experimental researches conditions of radiating sterilization of fruits of a barberry ?-radiation are picked up at small dozes and at different values ionizating radiations. Fruits of a barberry were irradiated with ?-radiation on radioisotope installation 60n-tildei-circumflex at values of a doze of an irradiation in limits from 1.0 up to 1.5eGr at duration of an irradiation till 30 minutes. The qualitative control were carried out chromatografic (thin layer chromatography) and spectral (UV-VIS and IR) methods later 6, 12 and 24 months

  17. Female sterilization in India : The quality and effect of an observed sterilization camp at The Methodist Public Health Centre, Mursan, India

    OpenAIRE

    Wikborg, Pia; Svensk, Marie

    2007-01-01

    Population growth is a big challenge for India, and family planning is highly prioritized by the Government of India. Sterilization is the most common voluntary contraceptive method in India and has for many years been performed in camps. This thesis is based on our observation of a sterilization camp at the Methodist Public Health Centre in Mursan, India and available literature on the subject. We have looked closer at the effect of female sterilization as a method of contraception and t...

  18. Influence of microwave sterilization on the cutting capacity of carbide burs.

    Science.gov (United States)

    Fais, Laiza Maria Grassi; Pinelli, Lígia Antunes Pereira; Adabo, Gelson Luis; Silva, Regina Helena Barbosa Tavares da; Marcelo, Caroline Canhizares; Guaglianoni, Dalton Geraldo

    2009-01-01

    This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control - no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 +/- 0.0627 g; G2 = 0.2077 +/- 0.0231 g; G3 = 0.1980 +/- 0.0326 g; G4 = 0.1203 +/- 0.0459 g; G5 = 0.2642 +/- 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.

  19. Objections to tubal sterilization: what reversibility can and cannot overcome.

    Science.gov (United States)

    Shain, R N

    1980-09-01

    In a study of 1074 women, 696 and 338 subjects would not seriously consider permanent and hypothetically reversible sterilization, respectively; they were asked to explain their feelings. The reason accounting for most objections to permanent sterilization (65%) was irreversibility and of the subjects who would not consider reversible sterilization or were unsure, 42.7% attributed their principal objection to unnecessary surgery, a factor at least currently intrinsic to the procedure and not readily overcome by education. Many of the remaining objections to both permanent and reversible sterilization may be amenable to change either through education or financial subsidies. In response to a question concerning female attractiveness subsequent to permanent sterilization, 3% of the sample felt attractiveness would decrease and 17.5% were unsure of the surgery's effect. Unsure responses were largely negative in character. This issue is important because of its relationship to intention to undergo sterilization. Upon consideration of reversible sterilization, negative and unsure responses significantly declined, even on the part of those women whose friends have had a poor experience with currently available procedures. Thus, whereas the option of reversibility cannot overcome objections to surgery, it does overcome those regarding permanency; moreover, the "temporary" character it bestows upon surgical sterilization appears to help certain individuals overcome their fears of losing their physical appeal as a result of such procedures.

  20. A simple genetic incompatibility causes hybrid male sterility in mimulus.

    Science.gov (United States)

    Sweigart, Andrea L; Fishman, Lila; Willis, John H

    2006-04-01

    Much evidence has shown that postzygotic reproductive isolation (hybrid inviability or sterility) evolves by the accumulation of interlocus incompatibilities between diverging populations. Although in theory only a single pair of incompatible loci is needed to isolate species, empirical work in Drosophila has revealed that hybrid fertility problems often are highly polygenic and complex. In this article we investigate the genetic basis of hybrid sterility between two closely related species of monkeyflower, Mimulus guttatus and M. nasutus. In striking contrast to Drosophila systems, we demonstrate that nearly complete hybrid male sterility in Mimulus results from a simple genetic incompatibility between a single pair of heterospecific loci. We have genetically mapped this sterility effect: the M. guttatus allele at the hybrid male sterility 1 (hms1) locus acts dominantly in combination with recessive M. nasutus alleles at the hybrid male sterility 2 (hms2) locus to cause nearly complete hybrid male sterility. In a preliminary screen to find additional small-effect male sterility factors, we identified one additional locus that also contributes to some of the variation in hybrid male fertility. Interestingly, hms1 and hms2 also cause a significant reduction in hybrid female fertility, suggesting that sex-specific hybrid defects might share a common genetic basis. This possibility is supported by our discovery that recombination is reduced dramatically in a cross involving a parent with the hms1-hms2 incompatibility.

  1. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Vijaya Krishnan

    2004-12-01

    Full Text Available Prior to early 1970s, traditional methods were the principal means of controlling the number and spacing of births. Today, an estimated 57 per cent of the world’s married women use contraceptives and half use modern methods such as medical sterilizations. Recent statistics suggest that Canada has the highest sterilization rate in the Western world. This paper presents findings of research examining sterilization trends in Canada with respect to changing patterns in the use of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995 General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligation and an increase in the use of hysterectomy over the period 1984-1995. Less educated women are more likely to be in the forefront of modern methods of contraception.

  2. Sterilization of the artificial blood circulation apparatus with ozone

    Energy Technology Data Exchange (ETDEWEB)

    Pisarevskii, A A; Korukhov, N I.U.; Brazhnikov, E M; Konstantinova, M L; Razumovskii, S D

    1982-01-01

    Presented in this paper is the sterilization method of the assisted circulation unit. The method has been approved by stand testing and then applied for sterilizing the unit Ae, yeK-5 m when experimental implanting artificial heart. According to the method, ozone in concentration of 5 x 10(-3) moles/1 and with flow rate of 0,5 1/min is passed through an internal circuit of the unit during I h and 15 min. Control wash-out samples from lines have demonstrated complete sterility of the internal circuit. The method makes the sterilization process of such units much easier and may be recommended for clinical application.

  3. Field evaluations of the VDmax approach for substantiation of a 25 kGy sterilization dose and its application to other preselected doses

    International Nuclear Information System (INIS)

    Kowalski, John B.; Herring, Craig; Baryschpolec, Lisa; Reger, John; Patel, Jay; Feeney, Mary; Tallentire, Alan

    2002-01-01

    The International and European standards for radiation sterilization require evidence of the effectiveness of a minimum sterilization dose of 25 kGy but do not provide detailed guidance on how this evidence can be generated. An approach, designated VD max , has recently been described and computer evaluated to provide safe and unambiguous substantiation of a 25 kGy sterilization dose. The approach has been further developed into a practical method, which has been subjected to field evaluations at three manufacturing facilities which produce different types of medical devices. The three facilities each used a different overall evaluation strategy: Facility A used VD max for quarterly dose audits; Facility B compared VD max and Method 1 in side-by-side parallel experiments; and Facility C, a new facility at start-up, used VD max for initial substantiation of 25 kGy and subsequent quarterly dose audits. A common element at all three facilities was the use of 10 product units for irradiation in the verification dose experiment. The field evaluations of the VD max method were successful at all three facilities; they included many different types of medical devices/product families with a wide range of average bioburden and sample item portion values used in the verification dose experiments. Overall, around 500 verification dose experiments were performed and no failures were observed. In the side-by-side parallel experiments, the outcomes of the VD max experiments were consistent with the outcomes observed with Method 1. The VD max approach has been extended to sterilization doses >25 and max method for doses other than 25 kGy must await controlled field evaluations and the development of appropriate specifications/standards

  4. Reliability assessment platform for the power semiconductor devices - Study case on 3-phase grid-connected inverter application

    DEFF Research Database (Denmark)

    Vernica, Ionut; Ma, Ke; Blaabjerg, Frede

    2017-01-01

    provide valuable reliability information based on given mission profiles and system specification is first developed and its main concept is presented. In order to facilitate the test and access to the loading and lifetime information of the power devices, a novel mission profile based stress emulator...... experimental setup is proposed and designed. The link between the stress emulator setup and the reliability tool software is highlighted. Finally, the reliability assessment platform is demonstrated on a 3-phase grid-connected inverter application study case....

  5. Glass bead sterilizer comprehensively defeats hot air oven in orthodontic clinic

    Directory of Open Access Journals (Sweden)

    Sanjeev Vasudev Jakati

    2015-01-01

    Full Text Available Background: It is necessary to ′try in′ several bands before the correct one is selected. A possible concern with re-using such bands is the lack of cross-infection control. Aim and Objectives: To determine whether such bands could be successfully decontaminated with Glass bead sterilization so that they could be re-used without a cross-infection risk. Materials: Custom made molar bands were taken and buccal tubes,lingual sheath and lingual cleat were welded under strict aseptic conditions. Methods: Samples were divided into 2 groups i.e. A and B, based on mode for sterilization. Sterilized attachments were placed in each of 2 conical flask. The bacteria spores were inoculated into both flask under strict aseptic conditions. Bacteria Bacillus subtillis and Staphylococcus albus species were allowed to multiply in individual flasks filled with BHI broth for 24 hours. Bands from 1st group were placed in a glass bead sterilizer. For the 2 nd group i.e. hot air oven group, all bands were placed together. After sterilization bands were removed and placed in freshly sterilized 500ml conical flask containing BHI broth for 24 hours in the incubator. The following day randomly 4 attachments were selected from each group and streaked on blood agar culture plates. Results: After sterilization and on further incubation in BHI broth for 24 and 48 hrs. Respectively no growth was seen. Conclusion: 1 hr. of Hot Air Oven sterilization (excluding pre sterilization heat up time and post sterilization cooling time at 190°C is as effective as 3 min of Chair side Glass Bead sterilization.

  6. Sterilization Monitoring management of the integration of the operating room with CSSD

    Directory of Open Access Journals (Sweden)

    Shu-yan XIA

    2014-08-01

    Full Text Available Objective: Explore the Sterilization Monitoring management of the integration of the operating room with CSSD. Methods: Compare sterilization process monitoring with biological monitoring and chemical monitoring. Results: The management in Biological monitoring, chemical monitoring and sterilization process monitoring is crucial. Conclusion: Sterilization monitoring is to ensure the safe use of sterile goods so as to protect the safety of surgical patients.

  7. Temperature Effects on Free Radicals in Gamma-sterilized Beef

    Science.gov (United States)

    Pramanik, S. I.; Jahan, M. S.

    1999-11-01

    Gamma irradiation has become the method of choice for sterilizing frozen meat and their products to reduce levels of food-borne pathogens and to extend shelf life. In this report we have employed ESR technique for detection of free radicals in sterilized and non-sterilized dry beef without bone. We have also determined the heating effects on free radicals at temperatures 176^°C and 250^°C. Meat samples were dried in a food dehydrator at 60^°C and were packaged in dry N_2. They were then sterilized by γ-irradiation (2.5 MRad), ground into powder, and placed in ESR sample tubes. Non-sterilized powder samples were used as control. While all powder samples, sterilized or not, produced a broad single line in the ESR spectra with (Δ H_pp ~ 9 G) and g = 2.013, the radical concentration in the sterilized samples increased by a factor of five. Heat treatment at 176^°C produced similar radicals. But, when samples were heated 250^°C different radical species were formed which are characterized by narrow width (Δ H_pp ~ 6 G) and lower g-value (g =2.010). In contrast with previous work, where free radicals in chicken bones were reduced by heating [1], we observed an increase in concentration. Results of structural analyses of the radicals will be presented. Ref.[1]: Radiat. Phys. Chem., 49, 477-481, 1997. Work supported by Grants from the University of Memphis

  8. Laboratory methods used for testing the effect of radiation sterilization and preservation procedures on bone allografts

    International Nuclear Information System (INIS)

    Dziedzic-Goclawska, A.

    1999-01-01

    Sterilization of tissue allografts with ionizing radiation introduced in the mid of 1950s is more and more frequently used in tissue banking practice. The dose of 25 kGy is currently recommended and commonly used by many tissue banks in the world with the exception of the Central Tissue Bank in Warsaw where the dose of 33 kGy + 10 % has been routinely used since 1963, and from 1997 the dose of 35 kGy + 10 % has been introduced. To study the effect of radiation-sterilization on bone allografts the interdisciplinary investigations have been undertaken and several techniques have been implemented in our tissue bank. The electron paramagnetic resonance (EPR) spectroscopy has been applied to investigate the amount, origin and stability of free radicals and other paramagnetic entities induced in radiation-sterilized bone allografts. This technique has been also utilized for quantitative evaluation of remodeling process of radiation-sterilized bone allografts and for estimation of the absorbed dose of ionizing radiation using bone tissue as a dosimeter. A model of heterotopically induced osteogenesis after transplantation of devitalized bone matrix into the muscle (described by Urist in 1965) is very useful in tissue banking practice. It allows one to determine the contribution the graft itself makes to osteogenesis. This model is routinely used in our tissue bank to evaluate the effect of various sterilization and preservation procedures on osteoinductive properties of bone allografts. The solubility in vitro of collagen - a carrier for bone morphogenetic proteins (BMPS) and a major constituent of bone and the other connective tissue grafts, has been studied by measuring the amount of extracted neutral, acid and total soluble collagen from bone grafts preserved by different methods at irradiated at vanous experimental conditions. A positive correlation between collagen solubility in vitro and the rate of graft resorption in vivo has been observed. The high doses of

  9. Intermediate-term and long-term outcome of piggyback drainage: connecting glaucoma drainage device to a device in-situ for improved intraocular pressure control.

    Science.gov (United States)

    Dervan, Edward; Lee, Edward; Giubilato, Antonio; Khanam, Tina; Maghsoudlou, Panayiotis; Morgan, William H

    2017-11-01

    This study provides results of a treatment option for patients with failed primary glaucoma drainage device. The study aimed to describe and evaluate the long-term intraocular pressure control and complications of a new technique joining a second glaucoma drainage device directly to an existing glaucoma drainage device termed 'piggyback drainage'. This is a retrospective, interventional cohort study. Eighteen eyes of 17 patients who underwent piggyback drainage between 2004 and 2013 inclusive have been studied. All patients had prior glaucoma drainage device with uncontrolled intraocular pressure. The piggyback technique involved suturing a Baerveldt (250 or 350 mm) or Molteno3 glaucoma drainage device to an unused scleral quadrant and connecting the silicone tube to the primary plate bleb. Failure of intraocular pressure control defined as an intraocular pressure greater than 21 mmHg on maximal therapy on two separate occasions or further intervention to control intraocular pressure. The intraocular pressure was controlled in seven eyes (39%) at last follow-up with a mean follow-up time of 74.2 months. The mean preoperative intraocular pressure was 27.1 mmHg (95% confidence interval 23.8-30.3) compared with 18.4 mmHg (95% confidence interval 13.9-22.8) at last follow-up. The mean time to failure was 57.1 months (95% confidence interval 32.2-82), and the mean time to further surgery was 72.3 months (95% confidence interval 49.9-94.7). Lower preoperative intraocular pressure was associated with longer duration of intraocular pressure control (P = 0.048). If the intraocular pressure was controlled over 2 years, it continued to be controlled over the long term. Two eyes (11%) experienced corneal decompensation. Piggyback drainage represents a viable surgical alternative for the treatment of patients with severe glaucoma with failing primary glaucoma drainage device, particularly in those at high risk of corneal decompensation. © 2017 Royal Australian and New Zealand

  10. Cosmological lepton asymmetry, primordial nucleosynthesis and sterile neutrinos

    Science.gov (United States)

    Abazajian, Kevork; Bell, Nicole F.; Fuller, George M.; Wong, Yvonne Y. Y.

    2005-09-01

    We study post weak decoupling coherent active-sterile and active-active matter-enhanced neutrino flavor transformation in the early Universe. We show that flavor conversion efficiency at Mikheyev-Smirnov-Wolfenstein resonances is likely to be high (adiabatic evolution) for relevant neutrino parameters and energies. However, we point out that these resonances cannot sweep smoothly and continuously with the expansion of the Universe. We show how neutrino flavor conversion in this way can leave both the active and sterile neutrinos with nonthermal energy spectra, and how, in turn, these distorted energy spectra can affect the neutron-to-proton ratio, primordial nucleosynthesis, and cosmological mass/closure constraints on sterile neutrinos. We demonstrate that the existence of a light sterile neutrino which mixes with active neutrinos can change fundamentally the relationship between the cosmological lepton numbers and the primordial nucleosynthesis He4 yield.

  11. Semiconductor sensor device, diagnostic instrument comprising such a device and method of manufacturing such a device

    NARCIS (Netherlands)

    2010-01-01

    The invention relates to a semiconductor sensor device (10) for sensing a substance comprising at least one mesa- shaped semiconductor region (11) which is formed on a surface of a semiconductor body (12) and which is connected at a first end to a first electrically conducting connection region (13)

  12. The genetics of hybrid male sterility between the allopatric species pair Drosophila persimilis and D. pseudoobscura bogotana: dominant sterility alleles in collinear autosomal regions.

    Science.gov (United States)

    Chang, Audrey S; Noor, Mohamed A F

    2007-05-01

    F(1) hybrid male sterility is thought to result from interactions between loci on the X chromosome and dominant-acting loci on the autosomes. While X-linked loci that contribute to hybrid male sterility have been precisely localized in many animal taxa, their dominant autosomal interactors have been more difficult to localize precisely and/or have been shown to be of relatively smaller effect. Here, we identified and mapped at least four dominant autosomal factors contributing to hybrid male sterility in the allopatric species pair Drosophila persimilis and D. pseudoobscura bogotana. Using these results, we tested predictions of reduced recombination models of speciation. Consistent with these models, three of the four QTL associated with hybrid male sterility occur in collinear (uninverted) regions of these genomes. Furthermore, these QTL do not contribute significantly to hybrid male sterility in crosses between the sympatric species D. persimilis and D. pseudoobscura pseudoobscura. The autosomal loci identified in this study provide the basis for introgression mapping and, ultimately, for molecular cloning of interacting genes that contribute to F(1) hybrid sterility.

  13. Unintended pregnancies after Essure sterilization in the Netherlands

    NARCIS (Netherlands)

    Veersema, S.; Vleugels, M.P.; Moolenaar, L.M.; Janssen, C.A.; Brölmann, H.A.M.

    2010-01-01

    Objective: To analyze the data of cases of unintended pregnancies after Essure sterilization. Design: Retrospective case series analysis. Setting: National multicenter. Patient(s): Ten cases of unintended pregnancies after Essure sterilization in the Netherlands were reported from August 2002

  14. Plasma Sterilizer with Ultrasonic Cavitation

    International Nuclear Information System (INIS)

    Krasnyj, V.V.; Klosovsky, A.V.; Panasko, T.A.; Shvets, O.M.; Semenova, O.T.; Taran, V.S.; Tereshin, V.I.

    2006-01-01

    A sterilizer consists of ozone generator based on a barrier glow discharge with the flat electrodes covered with dielectric with a high-voltage pulsed power supply of up to 250 W (1). The sterilization camera is equipped with ultrasonic source with the power of 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. Ozone concentration in the aqueous solution was 6 mg/liter with ozone concentration at the output of ozone generator 30 mg/liter. The complete inactivation of spores took 15 min

  15. Hysteroscopic tubal sterilization: a systematic review of the Essure system

    DEFF Research Database (Denmark)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika

    2010-01-01

    OBJECTIVE: To update the evidence of the efficacy and safety of the Essure system. Female sterilization has undergone changes in the last decade. Besides laparoscopic tubal occlusion, the Essure system is now a viable option, with about 200,000 women sterilized using this method. DESIGN: The review...... in ambulatory settings. However, sterilization is not immediate and women must use additional contraception for 3 months until permanent tubal occlusion is verified by transvaginal ultrasound, hysterosalpingosonography, hysterosalpingography, or pelvic radiography. The evidence on efficacy and safety is mainly...... sterilization, but more information on the total cost is needed. CONCLUSION(S): The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published...

  16. Microbiological aspects relating to the choice of radiation sterilization dose

    International Nuclear Information System (INIS)

    Whitby, J.L.

    1993-01-01

    Ionizing radiation is widely used for sterilization of single-use medical devices, and it is employed for its lethal effect on microbial life. Microbes are capable of regenerating from a single surviving cell, and individual cells of some microbial species are highly resistant to the lethal effects of radiation. It is necessary to employ radiation doses far in excess of those lethal to man or animals to ensure that no viable microbe remains to repopulate the device or the patient at the time that the device is used. Ionizations induce the production of short-lived free radicals that also induce lethal changes in cells. The sensitivity of microbial species to these changes varies markedly but since the changes are induced within the cell, each cell has to sustain the necessary amount of lethal damage before death will occur. Therefore the death of cells will occur in the exponential mode the surviving fraction decreasing with increasing dose. Using a semi-logarithmic plot, curves of three types may be generated, a simple exponential curve with a constant slope over the whole dose range, one where an initial shoulder is followed by a constant slope, and curves which are concave, and only seen in mixed bacterial populations of differing radiation resistance. (author)

  17. Post-sterilization autonomy among young mothers in South India.

    Science.gov (United States)

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  18. Research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang; Ouyang Qiongli

    2010-01-01

    Radiation sterilization is widely applied in food processing, pharmaceutical manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. There are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the restrictions of capacity and inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  19. Influence of microwave sterilization on the cutting capacity of carbide burs

    Directory of Open Access Journals (Sweden)

    Laiza Maria Grassi Fais

    2009-12-01

    Full Text Available OBJECTIVE: This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. MATERIAL AND METHODS: Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1, autoclave (G2, microwave irradiation (G3, glutaraldehyde (G4 or control - no sterilization (G5. The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5 following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. RESULTS: The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 ± 0.0627 g; G2 = 0.2077 ± 0.0231 g; G3 = 0.1980 ± 0.0326 g; G4 = 0.1203 ± 0.0459 g; G5 = 0.2642 ± 0.0359 g. There were statistically significant differences among the groups (p<0.05; only dry heat sterilization was similar to the control. CONCLUSION: Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.

  20. The context and limitations of female sterilization services in Pakistan.

    Science.gov (United States)

    Khan, Adnan Ahmad; Khan, Ayesha; Abbas, Khadija; Tirmizi, Syed Farhan Ali; ul Islam, Zia

    2013-04-01

    Female sterilization has long been the most popular method of family planning (FP) in Pakistan, and yet most public health experts feel it contributes little to controlling family size or to population welfare. We used Pakistan Demographic Health Survey (PDHS) data to understand the role female sterilization plays in the overall context of FP in Pakistan. We performed a secondary analysis of data from the PDHS 1990-1 and 2006-7 to study factors that lead to sterilization and trends in the use of the procedure. In addition, census data were multiplied by proportions from PDHS data to estimate the number of women availing sterilization services. Around 1.9 million women in Pakistan are currently sterilized--up from 0.55 million in 1990-1, and around 173,867 undergo the procedure, annually. Women usually receive sterilization after 30 years of age (mean = 39) and after six children. The probability of sterilization increases with age, family size, and urban residence, and is unaffected by poverty, province of residence, or the woman or her husband's education. Most sterilizationis conducted in public sector facilities. Sterilization in Pakistan may be common, but occurs too late to have any significant effect on family size or benefit public health. Future avenues to make this option more useful to women and society would be to improve the repertoire and access and quality of FP services that are available, and to address governance issues that limit the performance and utility of government facilities.

  1. Radiation Sterilization of Two Commonly Culture Media Used for Bacterial Growth

    International Nuclear Information System (INIS)

    El-Hifnawi, H.N.

    2008-01-01

    Radiation sterilization of culture media used for the cultivation of bacteria by Co-60 gamma ray was investigated. Nutrient agar and tryptone glucose yeast extract (TGY) media widely used for the propagation of bacteria were sterilized with 15 kGy dose gamma radiation. Seven different bacterial species were grown as well on the radiation sterilized media as on media sterilized by autoclaving in a conventional way

  2. Eugenics, sterilization, and historical memory in the United States

    Directory of Open Access Journals (Sweden)

    Alexandra Minna Stern

    Full Text Available Abstract From the 1920s to the 1950s, California sterilized approximately 20,000 people in state homes and hospitals based on a eugenic law that authorized medical superintendents to perform reproductive surgeries on patients deemed unfit and “suffering from a mental affliction likely to be inherited.” Working with a unique resource – a dataset created from 19,000 sterilization recommendations – my team and I have reconstructed patterns and experiences of institutionalization of sterilizations. This article presents several of our important initial findings related to ethnic and gender bias in sterilization policies, and reflects on the relevance of the history for contemporary issues in genomics and social justice.

  3. Gamma radiation sterilized amnion: use in ophthalmology

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Leon T, Y. [Hospital General Regional 220, IMSS, Paseo Tollocan No. 620, Col. Vertice, Toluca 50150, Estado de Mexico (Mexico); Vazquez M, L., E-mail: esther.martinez@inin.gob.m [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06720 Mexico D. F. (Mexico)

    2010-10-15

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with {sup 60}Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  4. Gamma radiation sterilized amnion: use in ophthalmology

    International Nuclear Information System (INIS)

    Martinez P, M. E.; Leon T, Y.; Vazquez M, L.

    2010-10-01

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with 60 Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  5. Radiation Fusion Technology for Sewage Sterilization

    International Nuclear Information System (INIS)

    Lee, M. J.; Kim, T. H.; Ryu, S. H.; Jung, I. H.; Lee, O. M.; Kim, T. H.

    2011-01-01

    Environmental regulation for effluent of sewage and wastewater treatment plant is going to be reinforced in terms of ecology toxicity and number of E.coli from 2011. Besides, it has been known that UV technology is not enough to be a sterilization tool due to regrowth of E.coli even after treatment with UV. Therefore it needs a novel technology for both restriction of E.coli regrowth and treatment of toxic materials in order to meet the environmental regulation being enforced. Electron beam has unique capabilities on destruction of chemicals and sterilization of microbial. In this study, field study on destruction of antibiotics and endocrine disruptors, reduction ecological toxicity and E.Coli regrowth was carried out using by mobile electron beam accelerator. Experimental results showed that irradiation on effluent could effectively reduce not only ecology toxicity but regrowth of E.coli by destruction of chemicals and complete sterilization

  6. Mating competitiveness of sterile male Anopheles coluzzii in large cages.

    Science.gov (United States)

    Maïga, Hamidou; Damiens, David; Niang, Abdoulaye; Sawadogo, Simon P; Fatherhaman, Omnia; Lees, Rosemary S; Roux, Olivier; Dabiré, Roch K; Ouédraogo, Georges A; Tripet, Fréderic; Diabaté, Abdoulaye; Gilles, Jeremie R L

    2014-11-26

    Understanding the factors that account for male mating competitiveness is critical to the development of the sterile insect technique (SIT). Here, the effects of partial sterilization with 90 Gy of radiation on sexual competitiveness of Anopheles coluzzii allowed to mate in different ratios of sterile to untreated males have been assessed. Moreover, competitiveness was compared between males allowed one versus two days of contact with females. Sterile and untreated males four to six days of age were released in large cages (~1.75 sq m) with females of similar age at the following ratios of sterile males: untreated males: untreated virgin females: 100:100:100, 300:100:100, 500:100:100 (three replicates of each) and left for two days. Competitiveness was determined by assessing the egg hatch rate and the insemination rate, determined by dissecting recaptured females. An additional experiment was conducted with a ratio of 500:100:100 and a mating period of either one or two days. Two controls of 0:100:100 (untreated control) and 100:0:100 (sterile control) were used in each experiment. When males and females consort for two days with different ratios, a significant difference in insemination rate was observed between ratio treatments. The competitiveness index (C) of sterile males compared to controls was 0.53. The number of days of exposure to mates significantly increased the insemination rate, as did the increased number of males present in the untreated: sterile male ratio treatments, but the number of days of exposure did not have any effect on the hatch rate. The comparability of the hatch rates between experiments suggest that An. coluzzii mating competitiveness experiments in large cages could be run for one instead of two days, shortening the required length of the experiment. Sterilized males were half as competitive as untreated males, but an effective release ratio of at least five sterile for one untreated male has the potential to impact the fertility of

  7. Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test.

    Science.gov (United States)

    Freitas, Raphael Ribeiro de Aquino; Tardelli, Maria Angela

    2016-05-24

    To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. G1 and G2 showed no bacterial growth when compared to conventional groups (pgrupos, sendo que o G1 (n=16) continha as ampolas e o G2 (n=16), os frascos-ampola. As apresentações convencionais foram distribuídas em dois grupos, a saber G3 (n=16) com as ampolas e G4 (n=16) com os frascos-ampola. As ampolas e os frascos-ampolas eram abertos e tinham seu conteúdo aspirado. Os frascos vazios eram, então, acondicionados em sacos plásticos estéreis e enviados para análise quanto à carga microbiana (bactérias e fungos), bem como para o teste de esterilidade. Os dados foram analisados por meio do teste χ2 com correção Yates com intervalo de confiança de 95%. Os grupos G1 e G2 não apresentaram crescimento bacteriano quando comparado aos grupos convencionais (pgrupos. O uso de embalagens estéreis (sterile pack) diminui a carga microbiana dos frascos de envasamentos, o que diminuiria a chance de exposição a uma potencial contaminação da solução anestésica.

  8. Electric dipole moments of charged leptons with sterile fermions

    International Nuclear Information System (INIS)

    Abada, Asmaa; Toma, Takashi

    2016-01-01

    We address the impact of sterile fermions on charged lepton electric dipole moments. Any experimental signal of these observables calls for scenarios of physics beyond the Standard Model providing new sources of CP violation. In this work, we consider a minimal extension of the Standard Model via the addition of sterile fermions which mix with active neutrinos and we derive the corresponding analytical expressions for the electric dipole moments of charged leptons at two-loop order. Our study reveals that, in order to have a non-vanishing contribution in this framework, the minimal extension necessitates the addition of at least 2 sterile fermion states to the Standard Model field content. Our conclusion is that sterile neutrinos can give significant contributions to the charged lepton electric dipole moments, some of them lying within present and future experimental sensitivity if the masses of the non-degenerate sterile states are both above the electroweak scale. The Majorana nature of neutrinos is also important in order to allow for significative contributions to the charged lepton electric dipole moments. In our analysis we impose all available experimental and observational constraints on sterile neutrinos and we further discuss the prospect of probing this scenario at low and high energy experiments.

  9. Electric dipole moments of charged leptons with sterile fermions

    Energy Technology Data Exchange (ETDEWEB)

    Abada, Asmaa; Toma, Takashi [Laboratoire de Physique Théorique, CNRS, University Paris-Sud, Université Paris-Saclay, 91405 Orsay (France)

    2016-02-26

    We address the impact of sterile fermions on charged lepton electric dipole moments. Any experimental signal of these observables calls for scenarios of physics beyond the Standard Model providing new sources of CP violation. In this work, we consider a minimal extension of the Standard Model via the addition of sterile fermions which mix with active neutrinos and we derive the corresponding analytical expressions for the electric dipole moments of charged leptons at two-loop order. Our study reveals that, in order to have a non-vanishing contribution in this framework, the minimal extension necessitates the addition of at least 2 sterile fermion states to the Standard Model field content. Our conclusion is that sterile neutrinos can give significant contributions to the charged lepton electric dipole moments, some of them lying within present and future experimental sensitivity if the masses of the non-degenerate sterile states are both above the electroweak scale. The Majorana nature of neutrinos is also important in order to allow for significative contributions to the charged lepton electric dipole moments. In our analysis we impose all available experimental and observational constraints on sterile neutrinos and we further discuss the prospect of probing this scenario at low and high energy experiments.

  10. 'More than two': integrating biological control and sterile insects, from factory to field, and the possibility of its implementation in Argentina

    International Nuclear Information System (INIS)

    Cladera, Jorge L.; Viscarret, Mariana M.; Carabajal Paladino, Leonela Z.; Pietrek, Alejandro; Soria, M. Alejandra; Ovruski, Sergio M.

    2006-01-01

    No single control measure is able to provide full control of a pest. Integration of techniques like the sterile insect (SIT) with biological control practices (BC) should be intensively sough for. This possibility is revised here in connection with the fruit fly pest problems in Argentina. Theoretical reasons as well as practical conveniences for this integration are reviewed in this paper, the intention of which is to promote a discussion on how to approach the experimental study of the SIT+CB integration problem, i.e. how to measure the effects of each separate control measure as well as that of both acting together, in a repeatable manner. Arguments are advanced in favor of the joint production and releases of sterile fruit flies and parasitoids. (author)

  11. Optical properties of electrically connected plasmonic nanoantenna dimer arrays

    Science.gov (United States)

    Zimmerman, Darin T.; Borst, Benjamin D.; Carrick, Cassandra J.; Lent, Joseph M.; Wambold, Raymond A.; Weisel, Gary J.; Willis, Brian G.

    2018-02-01

    We fabricate electrically connected gold nanoantenna arrays of homodimers and heterodimers on silica substrates and present a systematic study of their optical properties. Electrically connected arrays of plasmonic nanoantennas make possible the realization of novel photonic devices, including optical sensors and rectifiers. Although the plasmonic response of unconnected arrays has been studied extensively, the present study shows that the inclusion of nanowire connections modifies the device response significantly. After presenting experimental measurements of optical extinction for unconnected dimer arrays, we compare these to measurements of dimers that are interconnected by gold nanowire "busbars." The connected devices show the familiar dipole response associated with the unconnected dimers but also show a second localized surface plasmon resonance (LSPR) that we refer to as the "coupled-busbar mode." Our experimental study also demonstrates that the placement of the nanowire along the antenna modifies the LSPR. Using finite-difference time-domain simulations, we confirm the experimental results and investigate the variation of dimer gap and spacing. Changing the dimer gap in connected devices has a significantly smaller effect on the dipole response than it does in unconnected devices. On the other hand, both LSPR modes respond strongly to changing the spacing between devices in the direction along the interconnecting wires. We also give results for the variation of E-field strength in the dimer gap, which will be important for any working sensor or rectenna device.

  12. Informed consent needed for sterilization or research.

    Science.gov (United States)

    Barnett, B

    1998-01-01

    Informed choice involves enabling family planning clients to base their decisions about contraceptive use upon adequate information. It is a process in which clients give their permission to undergo a procedure, take a medication, or participate in a study after being fully informed. Informed consent protects an individual's freedom of choice, respects his or her autonomy, is important in both family planning programs and reproductive health research, and should always be available to clients seeking health services. Although written informed consent is not needed for most reproductive health services, it should be obtained from men and women who undergo sterilization, since that involves surgery and is considered permanent. In addition, people who volunteer to participate in contraceptive studies need to be fully informed of the risks and benefits of any new drugs or devices they receive. Volunteers should understand the potential effects of methods upon their physical health and other aspects of their lives. Ethical reviews need to be conducted before research begins.

  13. The role of packaging size on contamination rates during simulated presentation to a sterile field.

    Directory of Open Access Journals (Sweden)

    Tony Trier

    Full Text Available The objective of this study was to assess the impact of package size on the contact between medical devices and non-sterile surfaces (i.e. the hands of the practitioner and the outside of the package during aseptic presentation to a simulated sterile field. Rationale for this objective stems from the decades-long problem of hospital-acquired infections. This work approaches the problem from a unique perspective, namely packaging size.Randomized complete block design with subsampling.Research study conducted at professional conferences for surgical technologists and nursing professionals.Ninety-seven healthcare providers, primarily surgical technologists and nurses.Participants were gloved and asked to present the contents of six pouches of three different sizes to a simulated sterile field. The exterior of pouches and gloves of participants were coated with a simulated contaminant prior to each opening trial. After presentation to the simulated sterile field, the presence of the contaminant on package contents was recorded as indicative of contact with non-sterile surfaces and analyzed in a binary fashion using a generalized linear mixed model.Recruited subjects were 26-64 years of age (81 females, 16 males, with 2.5-44 years of professional experience. Results indicated a significant main effect of pouch size on contact rate of package contents (P = 0.0108, whereby larger pouches induced greater rates of contact than smaller pouches (estimates±SEM: 14.7±2.9% vs. 6.0±1.7%, respectively.This study utilized novel methodologies which simulate contamination in aseptic presentation. Results of this work indicate that increased contamination rates are associated with larger pouches when compared to smaller pouches. The results add to a growing body of research which investigate packaging's role in serving as a pathway for product contamination during aseptic presentation. Future work should investigate other packaging design factors (e

  14. Geographic Variation in Characteristics of Postpartum Women Using Female Sterilization.

    Science.gov (United States)

    White, Kari; Potter, Joseph E; Zite, Nikki

    2015-01-01

    Southern states have higher rates of female sterilization compared with other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women's contraceptive method use between 2006 and 2009. We categorized states according to geographic region: South, Midwest/West, and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. The percentage of postpartum women using sterilization ranged from 5.0% to 9.9% in the Northeast, 8.9% to 10.6% in the Midwest/West, and 11.6% to 22.4% in the South. Women in nearly all subgroups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no differences in the prevalence of sterilization for Blacks compared with Whites in the Northeast (0.76; 95% CI, 0.55-1.06), Midwest/West (0.91; 95% CI, 0.80-1.04), and South (0.96; 95% CI, 0.85-1.07). Women with Medicaid-paid deliveries (vs. private insurance) had a higher prevalence of sterilization in all regions (p sterilization at disproportionately higher rates compared with other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  15. Remodeling of ACL Allografts is Inhibited by Peracetic Acid Sterilization

    Science.gov (United States)

    Gonnermann, Johannes; Kamp, Julia; Przybilla, Dorothea; Pruss, Axel

    2008-01-01

    Sterilization of allografts for anterior cruciate ligament (ACL) reconstruction has become an important prerequisite to prevent disease transmission. However, current sterilization techniques impair the biological or mechanical properties of such treated grafts. Peracetic acid (PAA) has been successfully used to sterilize bone allografts without these disadvantages and does not impair the mechanical properties of soft tissue grafts in vitro. We asked whether PAA sterilization would influence recellularization, restoration of crimp length and pattern, and revascularization of ACL grafts during early healing. We used an in vivo sheep model for open ACL reconstruction. We also correlated the histologic findings with the restoration of anteroposterior stability and structural properties during load-to-failure testing. PAA slowed remodeling activity at 6 and 12 weeks compared to nonsterilized allografts and autografts. The mechanical properties of PAA grafts were also reduced compared to these control groups at both time points. We conclude PAA sterilization currently should not be used to sterilize soft tissue grafts typically used in ACL reconstruction. PMID:18491201

  16. Intracavitary deposits on Essure® hysteroscopic sterilization devices: A case report

    Directory of Open Access Journals (Sweden)

    L.W. Maassen

    2017-07-01

    Capsule: Infrared spectroscopy of deposits on Essure® devices showed a pattern conclusive with calcite. The relationship between reported complaints and the formation of calcite deposits on Essure® remains unclear.

  17. Electron beam sterilization of water discharged from sewage

    International Nuclear Information System (INIS)

    Miyata, Teijiro; Arai, Hidehiko; Tokunaga, Okihiro; Machi, Sueo; Kondo, Masaki; Minemura, Takashi; Nakao, Akio; Seike, Yasuhiko.

    1989-01-01

    At present, the water treated at city sewerages is discharged to rivers after the chlorine sterilization, but it was clarified recently that this chlorine treatment produces carcinogenic organic chlorine compounds, and residual chlorine exerts harmful effect to aquatics, therefore, it is desirable to develop the sterilization techniques substituting for chlorine treatment. Already many reports elucidated that irradiation is effective for the sterilization of the water discharged from sewerage. However, as the technical subject for putting radiation process in practical use, the treatment of large quantity was a problem. Recently by the progress of the technology of manufacturing electron accelerators, the equipment with large power output which can treat in large quantity was developed, and it has become applicable also to sewage treatment. Therefore, the authors examined the practicality of electron beam process as the substitute technology for chlorine sterilizaiton. In the case of using electron beam, though the power output of accelerators is large, the flight range of electron beam in water is short. The comparison of the sterilization effect of electron beam with that of Co-60 gamma ray, the effects of water depth, discharged water quality and water velocity on the sterilization effect and so on were experimentally examined. (K.I.)

  18. Sterilization of microbes by using various plasma jets

    Energy Technology Data Exchange (ETDEWEB)

    Uhm, Han S.; Choi, Eun H.; Cho, Guang S. [Kwangwoon University, Seoul (Korea, Republic of); Hong, Yong C. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2012-03-15

    Sterilization of various microbes was carried out by using several plasma jets. Argon plasma jets penetrate deep into ambient air and create a path for oxygen radicals to sterilize microbes including spores. A sterilization experiment with bacterial endospores indicates that an argon-oxygen plasma jet very effectively kills endospores of Bacillus atrophaeus (ATCC 9372), thereby demonstrating its capability to clean surfaces and its usefulness for reinstating contaminated equipment as free from toxic biological agents. The key element of the sterilization is oxygen radicals. The penciltype configuration produces a long, cold plasma jet capable of reaching 3.5 cm and having various excited plasma species shown through the optical emission spectrum. Operation of an air plasma jet at 2 W in a pencil-type electrode provides an excellent opportunity for sterilization of microbes. An electron microscope was used to observe the effects of the plasma on bacterial cell morphology. Transmission electron micrographs showed morphological changes in E. coli cells treated with an atmospheric plasma at 75 W for 2 min. The treated cells had severe cytoplasmic deformations and leakage of bacterial chromosome. The chromosomal DNA was either attached to the bacterial cells or released freely into the surrounding medium. The results clearly explain the loss of viability of bacterial cells after plasma treatment.

  19. Degradation and stability of polycarbonate sterilized by gamma rays

    International Nuclear Information System (INIS)

    Araujo, E.S.; Guedes, S.M.L.

    1995-01-01

    The purpose of this paper is to study the behavior of the polycarbonate (poly (bis phenol-A carbonate)) when it is sterilized by gamma rays because undesirable discoloration appears. Aromatic polycarbonates are amorphous polymers usually prepared from bis phenols and phosgene by interfacial polymerization. They are employed in medical applications, including blood filters, dialyzers, oxygenators and sterilizing equipment. At present, the best process for sterilization of medical supplies is present, the best process for sterilization of medical supplies is gamma irradiation. The two major effects of γ-radiation in polymers are crosslinking and main chain scission. Both effects coexist and either one may predominate depending on the chemical structure of the polymer and the conditions of irradiation. (author). 5 refs, 6 figs, 1 tab

  20. Guide for dosimetry for sterile insect release programs. 2. ed.

    International Nuclear Information System (INIS)

    2004-01-01

    This guide outlines dosimetric procedures to be followed for the radiation sterilization of live insects for use in pest management programs. The primary use of irradiated, reproductively sterile insects is in the Sterile Insect Technique, where large numbers of sterile insects are released into the field to mate with and thus control pest populations of the same species. A secondary use of sterile insects is as benign hosts for rearing insect parasitoids. The procedures outlined in this guide will help ensure that insects processed with ionizing radiation from gamma, electron, or X-ray sources receive absorbed doses within a predetermined range. Information on effective dose ranges for specific applications of insect sterilization, or on methodology for determining effective dose ranges, is not within the scope of this guide. Note: Dosimetry is only one component of a total quality control program to ensure that irradiated insects are adequately sterilized and sufficiently competitive or otherwise suitable for their intended purpose. This guide covers dosimetry in the irradiation of insects for these types of irradiators: self-contained dry-storage 137 Cs or 60 Co irradiators, large-scale gamma irradiators, and electron accelerators. Additional, detailed information on dosimetric procedures to be followed in installation qualification, operational qualification, performance qualification, and routine product processing can be found in ISO/ASTM Practices 51608 (X-ray [bremsstrahlung] facilities), 51649 (electron beam facilities), 51702 (large-scale gamma facilities), and ASTM Practice E 2116 (self-contained dry-storage gamma facilities). The absorbed dose for insect sterilization is typically within the range of 20 Gy to 600 Gy

  1. Hysteroscopic tubal sterilization: a systematic review of the Essure system.

    Science.gov (United States)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika; Grahn, Riitta; Kukkonen-Harjula, Katriina; Nord-Saari, Merja; Mäkelä, Marjukka

    2010-06-01

    To update the evidence of the efficacy and safety of the Essure system. Female sterilization has undergone changes in the last decade. Besides laparoscopic tubal occlusion, the Essure system is now a viable option, with about 200,000 women sterilized using this method. The review is based on the report of the Alberta Heritage Foundation for Medical Research and completed with systematic literature searches up to April 8, 2008. The Managed Uptake of Medical Methods program of the Finnish National Research and Development Center for Health and Welfare. Women over 30 years, who had been sterilized by the Essure method. Hysteroscopic tubal sterilization using Essure system. Efficacy/effectiveness, adverse events, costs. Sterilization by Essure can be performed under local anesthesia or with oral analgesics in ambulatory settings. However, sterilization is not immediate and women must use additional contraception for 3 months until permanent tubal occlusion is verified by transvaginal ultrasound, hysterosalpingosonography, hysterosalpingography, or pelvic radiography. The evidence on efficacy and safety is mainly available from short follow-up case series but shows good efficacy and safety of the Essure system. Only a few small risks are associated with the procedure. Two economic studies, one of which implemented Essure as an in-office procedure, suggest that Essure could be more cost-effective than laparoscopic sterilization, but more information on the total cost is needed. The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  2. Sterilized PP/HMSPP cushion foams for medical and food packaging applications

    International Nuclear Information System (INIS)

    Cardoso, Elisabeth C.L.; Lima, L. Filipe C.P.; Parra, Duclerc F.; Lugao, Ademar B.; Bueno, N.R.; Gasparin, Eleosmar

    2009-01-01

    Treatment with gamma radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in aseptic processing of foods and pharmaceuticals. Packaging materials may be irradiated either prior or after filling; the irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceuticals and medical devices. Cushion foams are used to help protect fragile items during moving transport. Shock, vibration and damage are avoided by the cushioning effect and chances of product damage are reduced. It is easy to use and perforated for easy tearing. Cushion foams are employed to wrap glasses, plates, crockery, lamps, electronics and other breakable items. This paper presents special cushion foams to be used for medical and food packaging applications; so, these foams will be gamma irradiated before getting in contact with these special articles. Foams were previously produced from a 50% blending Polypropylene homopolymer / High Melt Strength Polypropylene (HMSPP) thereof, that presented following results for properties assessed: melt flow index, 230 deg C - 3.67 g/10 minutes; crystallinity = 47%; melt strength, at 200 deg C = 7.3 cN. This admixture was further fed into the barrel of a single-screw extruder, Rheomex 332 p, equipped with 3:1,33 d screw and 19/33 special screw for foaming, with standard controller and monitored panel, temperature controller (2 channels), melt temperature (2 channels) and melt pressure (4 channels). By using a 175/200/210/220/165/25 (deg C) profile temperature, and after attaining a homogeneous melting, a given amount of physical blowing agent (nitrogen) was injected and mixed with the polymer melt stream to produce the foam. Foamed extrudate was subjected to sterilization radiation doses: 25, 50, 75 and 100 kGy and further evaluated as per: appearance (whiteness / yellowness) and temperature dependent oxidative-induction time (TOIT) tests, by comparing

  3. Radiation sterilization of hydrocortisone acetate

    International Nuclear Information System (INIS)

    Charef, A.; Boussaha, A.

    1989-09-01

    The feasibility of using high energy ionizing radiation for the sterilization of hydrocortisone acetate was investigated. Hydrocortisone acetate in the form of powder was exposed to different dose levels of gamma radiation using a Cobalt-60 source. The irradiated samples were examined by various physico-chemical techniques in order to detect possible radiolysis products. It was of interest to know if one could insure sterility and retain biological properties of the drug by suitable choice of radiation dose. The results showed that a 10 KGy radiation dose causes no change in the physico-chemical properties of the drug and is sufficient to obtain contaminant-free product

  4. Atmospheric-pressure plasma decontamination/sterilization chamber

    Science.gov (United States)

    Herrmann, Hans W.; Selwyn, Gary S.

    2001-01-01

    An atmospheric-pressure plasma decontamination/sterilization chamber is described. The apparatus is useful for decontaminating sensitive equipment and materials, such as electronics, optics and national treasures, which have been contaminated with chemical and/or biological warfare agents, such as anthrax, mustard blistering agent, VX nerve gas, and the like. There is currently no acceptable procedure for decontaminating such equipment. The apparatus may also be used for sterilization in the medical and food industries. Items to be decontaminated or sterilized are supported inside the chamber. Reactive gases containing atomic and metastable oxygen species are generated by an atmospheric-pressure plasma discharge in a He/O.sub.2 mixture and directed into the region of these items resulting in chemical reaction between the reactive species and organic substances. This reaction typically kills and/or neutralizes the contamination without damaging most equipment and materials. The plasma gases are recirculated through a closed-loop system to minimize the loss of helium and the possibility of escape of aerosolized harmful substances.

  5. Surface sterilization method for reducing microbial contamination of ...

    African Journals Online (AJOL)

    An effective disinfection method for strawberry (Fragaria x ananassa Duch.) cv. Senga Sengana micropropagation using runner tips and nodal segments as explants was developed. The explants were surface sterilized with different sterilants for different durations. The present studies on the effect of different regimes of ...

  6. Effect of gamma irradiation on fertility of potato tuber moth males and study of inherited sterility phenomena in partially sterile males

    International Nuclear Information System (INIS)

    Saour, G.; Makee, H.

    1996-01-01

    Newly emerged adult males (0-18 h) potato tuber moth (PTM) phthorimaea operculella (Zeller) (Lepidoptera: Gelechiidae) were irradiated with various doses of gamma irradiation ranging from 5 to 45 krad. Sterility in order of 91% was induced when males were irradiated with a dose of 45 Krad. Longevity of male PTM was not affected by the application of irradiation, while mating ability and frequency of mating of the males irradiated with 25, 35 and 45 Krad were decreased. The mean number of eggs laid by females mated with males irradiated at 35 and 45 Krad was lower than the control. When males PTM were irradiated with high doses their competitiveness values were reduced, while the competitiveness was increased when the sex ratio of irradiated males to normal males was increased, specially with ration 1 : 10 : 1 (Normal male: Irradiated males: Normal female). Application of 15 Krad dose permitted, the ability to obtain a desired level of male sterility with acceptable reduction in its competitiveness. The inherited sterility phenomena in partially sterile males irradiated with 10-15 and 20 Krad was studied. Sterility in F1 progeny was higher than that in their irradiated male parents. The sex ratio of F1 progeny was distorted in favour of the males. (author). 24 refs., 5 figs

  7. Effect of gamma irradiation on fertility of potato tuber moth males and study of inherited sterility phenomena in partially sterile males

    Energy Technology Data Exchange (ETDEWEB)

    Saour, G; Makee, H [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Radiation Agriculture

    1996-01-01

    Newly emerged adult males (0-18 h) potato tuber moth (PTM) phthorimaea operculella (Zeller) (Lepidoptera: Gelechiidae) were irradiated with various doses of gamma irradiation ranging from 5 to 45 krad. Sterility in order of 91% was induced when males were irradiated with a dose of 45 Krad. Longevity of male PTM was not affected by the application of irradiation, while mating ability and frequency of mating of the males irradiated with 25, 35 and 45 Krad were decreased. The mean number of eggs laid by females mated with males irradiated at 35 and 45 Krad was lower than the control. When males PTM were irradiated with high doses their competitiveness values were reduced, while the competitiveness was increased when the sex ratio of irradiated males to normal males was increased, specially with ration 1 : 10 : 1 (Normal male: Irradiated males: Normal female). Application of 15 Krad dose permitted, the ability to obtain a desired level of male sterility with acceptable reduction in its competitiveness. The inherited sterility phenomena in partially sterile males irradiated with 10-15 and 20 Krad was studied. Sterility in F1 progeny was higher than that in their irradiated male parents. The sex ratio of F1 progeny was distorted in favour of the males. (author). 24 refs., 5 figs.

  8. American Sterilization: The Racist Justifications for Sterilization in the United States

    OpenAIRE

    Trevor Price

    2016-01-01

    An investigative analysis into anthropometrics, sterilization, eugenics, and other forms of scientific racism used to justify white supremacy and racial thought in the 19th and 20th centuries in the United States. The Tuskegee syphilis study, Darwinistic ideals, and neo-Lamarckian thoughts are critically analyzed as justifications for institutional racism.

  9. The causes of genetic male sterility in 3 soybaen lines.

    Science.gov (United States)

    Rubaihayo, P R; Gumisiriza, G

    1978-11-01

    The cause of male sterility in 3 soybean lines, TGM 103-1, N-69-2774 and TGM 242-4 was studied. In TGM 103-1, which was both male and female sterile, two different abnormalities were associated with sterility. Precocious movement of a few chromosomes at the metaphase I stage resulted into the production of non-functional pollen while cells which underwent apparent normal meiotic division had disintergration of the tapetal cell wall immediately after the free microspore stage leading to the starvation and subsequent death of the developing microspores. In lines N-69-2774 and TGM 242-4, both of which were partially sterile, male sterility resulted from a failure of cytokinesis after the telophase II stage. Meiosis proceeded normally but the 4 microspores after telophase II failed to separate into pollen grains and degenerated thereafter.

  10. A research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang

    2010-01-01

    Radiation sterilization is widely applied in food processing, Pharmaceutical Manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. The output value of radiation sterilization industry reached 0.1% of the GDP in some advanced countries (America and Japan...), under this standard, its output value in Sichuan province would be RMB1.2 hundred million, but now our capacity and scale of this industry is less than RMB40million.Research shows: there are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the 'bottleneck' restrictions of capacity and Inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity for radiation sterilization, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  11. Device of connecting the metal sheet lining a concrete enclosure to a pipe opening inside the enclosure

    International Nuclear Information System (INIS)

    Petit, Guy.

    1975-01-01

    Said invention relates to a sealed device connecting a metal sheet anchored on the internal side of a concrete vessel containing a hot pressurized fluid, with a metallic pipe opening inside said vessel. It is intended for heat insulating structures so-called 'hot skin' used for the pressure vessels of some boiling water reactors. Said invention is intended for different types of said pipe such as: the penetrations for the inlets and outlets of the primary circuit, or anchoring cylindrical sheaths used as supports of components or other elements located inside said pressure vessel [fr

  12. Effect of fermentation and sterilization on anthocyanins in blueberry.

    Science.gov (United States)

    Nie, Qixing; Feng, Lei; Hu, Jielun; Wang, Sunan; Chen, Haihong; Huang, Xiaojun; Nie, Shaoping; Xiong, Tao; Xie, Mingyong

    2017-03-01

    Blueberry products have various health benefits due to their high content of dietary anthocyanins. The aim of this study was to investigate the impact of fermentation and sterilization on total anthocyanin content, composition and some quality attributes of blueberry puree. The blueberry puree used here was fermented for 40 h at 37 °C by Lactobacillus after sterilization. The method of ultra-performance liquid chromatography-mass spectrometry was optimized for the rapid analysis of anthocyanins. Quality attributes including pH, color, total soluble solids and viscosity were measured. A total of 21 anthocyanins and five anthocyanidins were quantified by ultra-performance liquid chromatography. Fermented blueberry had reduced total anthocyanin content (29%) and levels of individual anthocyanins compared with fresh blueberry. Total anthocyanin content was decreased 46% by sterilization, and different degradation behavior of individual anthocyanin was appeared between fermented and sterilized-fermented blueberry puree. Fermentation and sterilization decreased the total soluble solids and pH and changed color parameters, while minimally influencing viscosity. The loss of total anthocyanin content by fermentation was related to the unstable structure of blueberry anthocyanins. Anthocyanins are sensitive to temperature (>80 °C), and degradation of anthocyanins by sterilization in blueberry should be considered in the fermentation procedure. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  13. Gamma radiations an effective way of monoclonal antibodies sterilization

    International Nuclear Information System (INIS)

    Lenay Barrera Barroso, Lenay; Otero Abreu, Isabel; Rodriguez Napoles, Dania; Bulte Ocanna, Dubhe; Caballero, Idania

    2006-01-01

    The sterilization for radiations of pharmaceutical products is an effective, sure and reliable procedure; that it have been proving technically and grateful for different pharmacopoeia. The Monoclonal Antibodies (Acm) produced in the Center of Molecular Immunology (CIM) are products parenteral for the one which results indispensable that they complete the requirements of established sterility. The radio sterilization result the method more recommend for the sterilization of the Acm deep drying, due to the contained first floor of humidity remnant that minimizes the formation of sub-product that they affect their properties. With the objective of proposing a good dose of irradiation for the sterilization, we were carried out a study of the radius sensibility so much of the product like of the polluting of greater frequency of isolation of the clean area of the CIM. The characterization of the radius sensibility of the different micro- organisms was determined by D 10 characteristic of each isolated strains. From the developed studies the Gram-positive rods endospore-forming were the most resistant strains at the deep drying, the radiations and they were of the greater frequency of apparition in the carried out isolations. We could conclude that utilizing a dose of 10 kGy it is possible to eliminate of the pollution more radio resistant, assuring the sterility required in the product, and without inducing effects under desire radiolytic in the same

  14. Evaluation of Effects of Sterilization on Mechanical Properties of Orthodontic Wires

    Directory of Open Access Journals (Sweden)

    Sridhar Kannan

    2012-01-01

    Results: Dry heat sterilization, autoclave, 2% glutaraldehyde solution had no effect on ultimate tensile strength, 0.1% yield strength, modulus of elasticity and percentage elongation of stainless steel and elgiloy wires. Tensile strength and yield strength of Nitinol and b-titanium wires together with percentage elongation of b-titanium wires significantly increased following dry heat sterilization and autoclave. No detrimental effects on properties of wires were observed. These sterilization procedures could be safely recommended for sterilization of orthodontic wires.

  15. Gene, protein, and network of male sterility in rice

    OpenAIRE

    Wang, Kun; Peng, Xiaojue; Ji, Yanxiao; Yang, Pingfang; Zhu, Yingguo; Li, Shaoqing

    2013-01-01

    Rice is one of the most important model crop plants whose heterosis has been well-exploited in commercial hybrid seed production via a variety of types of male-sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and prot...

  16. Bidirectional current triggering in planar devices based on serially connected VO2 thin films using 965 nm laser diode.

    Science.gov (United States)

    Kim, Jihoon; Park, Kyongsoo; Kim, Bong-Jun; Lee, Yong Wook

    2016-08-08

    By incorporating a 965 nm laser diode, the bidirectional current triggering of up to 30 mA was demonstrated in a two-terminal planar device based on serially connected vanadium dioxide (VO2) thin films grown by pulsed laser deposition. The bidirectional current triggering was realized by using the focused beams of laser pulses through the photo-thermally induced phase transition of VO2. The transient responses of laser-triggered currents were also investigated when laser pulses excited the device at a variety of pulse widths and repetition rates of up to 4.0 Hz. A switching contrast between off- and on-state currents was obtained as ~8333, and rising and falling times were measured as ~39 and ~29 ms, respectively, for 50 ms laser pulses.

  17. Mechanisms of male sterility in higher plants

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Yasuo [Tsukuba Univ., Sakura, Ibaraki (Japan)

    1982-03-01

    The mechanisms causing male sterility in higher plants were classified into two major categories: genetic and non-genetic. The former was further divided into six classes: 1) Anomality in spindle mechanism during meiosis, 2) chromosomal anomality such as haploidy, polyploidy, aneuploidy, chromosome some deficiency, inversion and reciprocal translocation, 3) presence of male sterile genes, 4) cytoplasmic abnormality, 5) the combination of some specific cytoplasm with particular genes, and 6) infections of microorganisms or viruses. Each mechanism was briefly explained, and the methods for the maintenance of parent lines for heterosis breeding and hybrid seed production were described. The non-genetic male sterility was classified into four types, which are caused by 1) low or high temperature, 2) water deficiency, 3) application of chemicals, and 4) radiation, with a brief explanation given for each of them.

  18. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards...... and documented uncertainty limits of the dose measurements can be used to specify process control limits. This is also useful, for example, when dose setting experiments are carried out according to the methods described in ISO 11137, where product samples shall be irradiated within narrow limits......., the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  19. Do women's attitudes towards abortion and contraceptive methods influence their option for sterilization?

    Directory of Open Access Journals (Sweden)

    Elisabeth Meloni Vieira

    Full Text Available This paper analyzes the attitudes of low-income women towards abortion and contraception. A survey was conducted in 1992 with a total of 3,149 childbearing-age women living on the outskirts of the Greater Metropolitan São Paulo Area. The study focuses on a sub-sample of 583 women. Attitudes of sterilized and non-sterilized women are compared. Women, especially those sterilized, found the most important attribute of a contraceptive method to be its effectiveness. Women currently taking the pill were less likely than those sterilized to agree that sterilization was the best method because of its effectiveness. Sterilized women were less likely than non-sterilized women to trust the pill. Sterilized women were more likely than non-sterilized to have reported adverse effects from the pill. Most women found abortion unacceptable except in the case of risk to the woman's life. Women using more effective methods showed stronger negative attitudes towards abortion. The tendency to be sterilized while still young was associated with more negative attitudes towards abortion. Family planning activities in basic health care services should include individual counseling for contraceptive use.

  20. Do women's attitudes towards abortion and contraceptive methods influence their option for sterilization?

    Directory of Open Access Journals (Sweden)

    Vieira Elisabeth Meloni

    1999-01-01

    Full Text Available This paper analyzes the attitudes of low-income women towards abortion and contraception. A survey was conducted in 1992 with a total of 3,149 childbearing-age women living on the outskirts of the Greater Metropolitan São Paulo Area. The study focuses on a sub-sample of 583 women. Attitudes of sterilized and non-sterilized women are compared. Women, especially those sterilized, found the most important attribute of a contraceptive method to be its effectiveness. Women currently taking the pill were less likely than those sterilized to agree that sterilization was the best method because of its effectiveness. Sterilized women were less likely than non-sterilized women to trust the pill. Sterilized women were more likely than non-sterilized to have reported adverse effects from the pill. Most women found abortion unacceptable except in the case of risk to the woman's life. Women using more effective methods showed stronger negative attitudes towards abortion. The tendency to be sterilized while still young was associated with more negative attitudes towards abortion. Family planning activities in basic health care services should include individual counseling for contraceptive use.

  1. Identification of dominant male sterile mutants in rice (Oryza sativa L.)

    International Nuclear Information System (INIS)

    Zhu Xudong; Rutger, J.N.

    2000-01-01

    Genetic male sterile mutants 1783 and 1789 were selected from US variety Orion and Kaybonnet seeds treated by gamma irradiation. Investigation of fertility characterization of pollen and spikelets of these mutants were made by progeny tests in 1783 M 7 and 1789 M 6 generations. The results showed that genetic male sterile mutants 1783 and 1789 with the fertility segregating of 1 sterile: 1 fertile were controlled by a single dominant gene. The pollen staining of mutants characterized partial sterility. Open-pollinated seed set was about 30% and bagged seed set was only 0.3%-3.5%. It is concluded that dominant genetic male sterile is a useful tool in improvement of population for rice breeding

  2. Current systems of sterilization in the Philippines in both government and private hospitals

    International Nuclear Information System (INIS)

    Lim, L.E.

    1996-01-01

    In the Philippines, there are 1,700 registered hospitals, both private and government. There are 80,000 beds. The systems of sterilization are mainly using steam or to use ethylene oxide sterilization. Gamma ray sterilization is purely on experimental basis and very limited scale for industrial products. The author will trace the history of sterilization, practised since a century ago and trace back to the present system of sterilization. The principles applied, precautions and limitations or advantages of the different systems will be discussed particularly steam sterilization and ethylene oxide. Other forms of sterilization either chemical or physical will be discussed in passing. Experience in gamma ray sterilization in Japan and Australia will be presented when available data are obtained, to encourage local investors to engage in such venture. Philippines has been left behind by our neighbors. (author)

  3. Comparative evaluation of four different sterilization methods on contaminated endodontic files

    Directory of Open Access Journals (Sweden)

    Malathi Yenni

    2017-01-01

    Full Text Available Background: The reuse of instruments in the field of endodontics leads to cross infection due to contamination with microbes as the instruments come into direct contact with saliva, blood, and infected tissues. Since microbes are considered to be the major cause of endodontic failures, sterilization of endodontic instruments is mandatory for maintaining asepsis to prevent cross-contamination from one person to other. Hence, the present study was conducted to compare the effectiveness of four different methods of sterilizing contaminated endodontic files. Materials and Methods: A total of 48 stainless steel K files were divided into four groups based on the sterilization method followed – Group A: Autoclave, Group B: Glass bead sterilization, Group C: Glutaraldehyde, and Group D: Quitanet Plus (aldehyde-free solution. In all the tested groups, half of the files were contaminated with Escherichia coli and remaining with Enterococcus faecalis. Then, presterilization colony counts were recorded, followed by sterilization through respective methods. Later, the sterilized files were rinsed with distilled water and 100 ul of the diluted concentration was transferred and cultured onto the respective agar plates to determine the total microbial reduction. Results: Autoclave showed complete effectiveness in reducing the microbial count followed by Quitanet Plus, glass bead sterilizer, and glutaraldehyde. Conclusion: Autoclave is considered to be the best sterilization technique to prevent cross infection in endodontic therapy.

  4. Gamma-irradiation sterilization of lipases for cheese making

    Energy Technology Data Exchange (ETDEWEB)

    Umanskij, M S; Borovkova, Yu A; Odegov, N I [Vsesoyuznyj Nauchno-Issledovatel' skij Inst. Maslodel' noj i Syrodel' noj Promyshlennosti, Uglich (USSR)

    1979-03-01

    The possibility of sterilizing the enzyme compounds of lipases from Oospora fragrans strains by gamma irradiation was studied. The enzyme compounds were exposed to gamma irradiation at the doses from 0.1 to 0.8 Mrad with the discreteness of 0.1 Mrad and at the dose of 2.0 Mrad. After the radiation treatment the lipases were investigated for bacterial invasion by the cultivation method and for the lipolytic activity by the titrometrical method. It is shown that the sterilization effect is achieved without losses of lipase activity and the radiation dose necessary for sterilization depends on initial invasion levels in the enzyme compounds.

  5. Sterile Neutrino Search with the Double Chooz Experiment

    Science.gov (United States)

    Hellwig, D.; Matsubara, T.; Double Chooz Collaboration

    2017-09-01

    Double Chooz is a reactor antineutrino disappearance experiment located in Chooz, France. A far detector at a distance of about 1 km from reactor cores is operating since 2011; a near detector of identical design at a distance of about 400 m is operating since begin 2015. Beyond the precise measurement of θ 13, Double Chooz has a strong sensitivity to so called light sterile neutrinos. Sterile neutrinos are neutrino mass states not taking part in weak interactions, but may mix with known neutrino states. In this paper, we present an analysis method to search for sterile neutrinos and the expected sensitivity with the baselines of our detectors.

  6. Process variation in electron beam sterilization

    International Nuclear Information System (INIS)

    Beck, Jeffrey A.

    2012-01-01

    The qualification and control of electron beam sterilization can be improved by the application of proven statistical analysis techniques such as Analysis of Variance (ANOVA) and Statistical Tolerance Limits. These statistical techniques can be useful tools in: •Locating and quantifying the minimum and maximum absorbed dose in a product. •Estimating the expected process maximum dose, given a minimum sterilizing dose. •Setting a process minimum dose target, based on an allowance for random measurement and process variation. •Determining the dose relationship between a reference dosimeter and process minimum and maximum doses. This study investigates and demonstrates the application of these tools in qualifying electron beam sterilization, and compares the conclusions obtained with those obtained using practices recommended in Guide for Process Control in Radiation Sterilization. The study supports the following conclusions for electron beam processes: 1.ANOVA is a more effective tool for evaluating the equivalency of absorbed doses than methods suggested in . 2.Process limits computed using statistical tolerance limits more accurately reflect actual process variability than the AAMI method, which applies +/−2 sample standard deviations (s) regardless of sample size. 3.The use of reference dose ratios lends itself to qualification using statistical tolerance limits. The current AAMI recommended approach may result in an overly optimistic estimate of the reference dose adjustment factor, as it is based on application of +/−2(s) tolerances regardless of sample size.

  7. A White Paper on keV sterile neutrino Dark Matter

    Energy Technology Data Exchange (ETDEWEB)

    Adhikari, R. [Centre for Theoretical Physics, Jamia Millia Islamia (Central University), New Delhi-110025 (India); Agostini, M. [Gran Sasso Science Institute (INFN), L' Aquila (Italy); Ky, N. Anh [Institute of physics, Vietnam academy of science and technology, 10 Dao Tan, Ba Dinh, Hanoi (Viet Nam); Araki, T. [Department of physics, Saitama University, Shimo-Okubo 255, 338-8570 Saitama Sakura-ku (Japan); Archidiacono, M. [Department of Physics and Astronomy, University of Aarhus, DK-8000 Aarhus C (Denmark); Bahr, M. [University of California, Santa Barbara (United States); Baur, J. [Commissariat à l' énergie atomique et aux énergies alternatives, Centre de Saclay, DSM/IRFU, 91191 Gif-sur-Yvette (France); Behrens, J. [Westfälische Wilhelms Universität Münster, Institut für Kernphysik, Wilhelm Klemm-Str.9, D-48149 Münster (Germany); Bezrukov, F. [University of Connecticut (United States); Dev, P.S. Bhupal [Consortium for Fundamental Physics, School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); Borah, D. [Department of Physics, Indian Institute of Technology Guwahati, Assam-781039 (India); Boyarsky, A. [Universiteit Leiden - Instituut Lorentz for Theoretical Physics, P.O. Box 9506, NL-2300 RA Leiden, Netherlands (Netherlands); De Gouvea, A. [Northwestern University (United States); Pires, C.A. de S. [Departamento de Física, UFPB, Caixa Postal 5008, 58051-970, João Pessoa, PB (Brazil); De Vega, H.J. [CNRS LPTHE UPMC Univ P. et M. Curie Paris VI (France); and others

    2017-01-01

    We present a comprehensive review of keV-scale sterile neutrino Dark Matter, collecting views and insights from all disciplines involved—cosmology, astrophysics, nuclear, and particle physics—in each case viewed from both theoretical and experimental/observational perspectives. After reviewing the role of active neutrinos in particle physics, astrophysics, and cosmology, we focus on sterile neutrinos in the context of the Dark Matter puzzle. Here, we first review the physics motivation for sterile neutrino Dark Matter, based on challenges and tensions in purely cold Dark Matter scenarios. We then round out the discussion by critically summarizing all known constraints on sterile neutrino Dark Matter arising from astrophysical observations, laboratory experiments, and theoretical considerations. In this context, we provide a balanced discourse on the possibly positive signal from X-ray observations. Another focus of the paper concerns the construction of particle physics models, aiming to explain how sterile neutrinos of keV-scale masses could arise in concrete settings beyond the Standard Model of elementary particle physics. The paper ends with an extensive review of current and future astrophysical and laboratory searches, highlighting new ideas and their experimental challenges, as well as future perspectives for the discovery of sterile neutrinos.

  8. A search for sterile neutrinos with the latest cosmological observations

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Lu; Zhang, Jing-Fei [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Zhang, Xin [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Peking University, Center for High Energy Physics, Beijing (China)

    2017-06-15

    We report the result of a search for sterile neutrinos with the latest cosmological observations. Both cases of massless and massive sterile neutrinos are considered in the ΛCDM cosmology. The cosmological observations used in this work include the Planck 2015 temperature and polarization data, the baryon acoustic oscillation data, the Hubble constant direct measurement data, the Planck Sunyaev-Zeldovich cluster counts data, the Planck lensing data, and the cosmic shear data. We find that the current observational data give a hint of the existence of massless sterile neutrino (as dark radiation) at the 1.44σ level, and the consideration of an extra massless sterile neutrino can indeed relieve the tension between observations and improve the cosmological fit. For the case of massive sterile neutrino, the observations give a rather tight upper limit on the mass, which implies that actually a massless sterile neutrino is more favored. Our result is consistent with the recent result of neutrino oscillation experiment done by the Daya Bay and MINOS collaborations, as well as the recent result of cosmic ray experiment done by the IceCube collaboration. (orig.)

  9. Sterilizing elastomeric chains without losing mechanical properties. Is it possible?

    Directory of Open Access Journals (Sweden)

    Matheus Melo Pithon

    2015-06-01

    Full Text Available OBJECTIVE: To investigate the effects of different sterilization/disinfection methods on the mechanical properties of orthodontic elastomeric chains. METHODS: Segments of elastomeric chains with 5 links each were sent for sterilization by cobalt 60 (Co60 (20 KGy gamma ray technology. After the procedure, the elastomeric chains were contaminated with clinical samples of Streptococcus mutans. Subsequently, the elastomeric chains were submitted to sterilization/disinfection tests carried out by means of different methods, forming six study groups, as follows: Group 1 (control - without contamination, Group 2 (70°GL alcohol, Group 3 (autoclave, Group 4 (ultraviolet, Group 5 (peracetic acid and Group 6 (glutaraldehyde. After sterilization/disinfection, the effectiveness of these methods, by Colony forming units per mL (CFU/mL, and the mechanical properties of the material were assessed. Student's t-test was used to assess the number of CFUs while ANOVA and Tukey's test were used to assess elastic strength. RESULTS: Ultraviolet treatment was not completely effective for sterilization. No loss of mechanical properties occurred with the use of the different sterilization methods (p > 0.05. CONCLUSION: Biological control of elastomeric chains does not affect their mechanical properties.

  10. Genetic architecture of autosome-mediated hybrid male sterility in Drosophila.

    Science.gov (United States)

    Marín, I

    1996-04-01

    Several estimators have been developed for assessing the number of sterility factors in a chromosome based on the sizes of fertile and sterile introgressed fragments. Assuming that two factors are required for producing sterility, simulations show that one of these, twice the inverse of the relative size of the largest fertile fragment, provides good average approximations when as few as five fertile fragments are analyzed. The estimators have been used for deducing the number of factors from previous data on several pairs of species. A particular result contrasts with the authors' interpretations: instead of the high number of sterility factors suggested, only a few per autosome are estimated in both reciprocal crosses involving Drosophila buzzatii and D. koepferae. It has been possible to map these factors, between three and six per chromosome, in the autosomes 3 and 4 of these species. Out of 203 introgressions of different fragments or combinations of fragments, the outcome of at least 192 is explained by the mapped zones. These results suggest that autosome-mediated sterility in the male hybrids of these species is mediated by a few epistatic factors, similarly to X-mediated sterility in the hybrids of other Drosophila species.

  11. Handheld Devices with Wide-Area Wireless Connectivity: Applications in Astronomy Educational Technology and Remote Computational Control

    Science.gov (United States)

    Budiardja, R. D.; Lingerfelt, E. J.; Guidry, M. W.

    2003-05-01

    Wireless technology implemented with handheld devices has attractive features because of the potential to access large amounts of data and the prospect of on-the-fly computational analysis from a device that can be carried in a shirt pocket. We shall describe applications of such technology to the general paradigm of making digital wireless connections from the field to upload information and queries to network servers, executing (potentially complex) programs and controlling data analysis and/or database operations on fast network computers, and returning real-time information from this analysis to the handheld device in the field. As illustration, we shall describe several client/server programs that we have written for applications in teaching introductory astronomy. For example, one program allows static and dynamic properties of astronomical objects to be accessed in a remote observation laboratory setting using a digital cell phone or PDA. Another implements interactive quizzing over a cell phone or PDA using a 700-question introductory astronomy quiz database, thus permitting students to study for astronomy quizzes in any environment in which they have a few free minutes and a digital cell phone or wireless PDA. Another allows one to control and monitor a computation done on a Beowulf cluster by changing the parameters of the computation remotely and retrieving the result when the computation is done. The presentation will include hands-on demonstrations with real devices. *Managed by UT-Battelle, LLC, for the U.S. Department of Energy under contract DE-AC05-00OR22725.

  12. Sterilization of DACUS CUCUMIS FRENCH (DIPTERA:TEPHRITIDAE) by gamma radiation

    International Nuclear Information System (INIS)

    Hooper, G.H.S.

    1975-01-01

    The effect of gamma radiation administered to newly emerged adults of Dacus cucumis French on sterility and competitiveness was evaluated. A dose of 11 krad caused almost complete sterility in males while females given 6 krad were totally sterile, through infecundity. Sterilized males showed reduced competitiveness. In competitive mating tests a dose of 7 krad gave the lowest egg hatch and this hatch was significantly lower than that given by 9 and 11 krad. In a paired comparison mating test, 7 and 9 krad treated males mated significantly less frequently than untreated males, but the ability of 6 krad treated males was unimpared. (author)

  13. Supercritical Carbon Dioxide–Based Sterilization of Decellularized Heart Valves

    Directory of Open Access Journals (Sweden)

    Ryan S. Hennessy, MD

    2017-02-01

    Full Text Available Summary: Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid– and supercritical carbon dioxide–treated valves were found to be sterile using histology, microbe culture, and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide–treated valves were higher compared with valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Key Words: decellularized, decontamination, heart valve, tensile properties, tissue engineering

  14. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    International Nuclear Information System (INIS)

    Huang, Junting

    2015-01-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states v e , v μ and v τ . In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ 24 in the range of 10 -2 eV 2 < Δm 43 2 < 1 eV 2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  15. Benchmarking of Sterilizing grade filters with liposome Filtration.

    Science.gov (United States)

    Loewe, Thomas; Mundlamuri, Ramesh; Loewe, Thomas; Mundrigi, Ashok; Handt, Sebastian; Singh, Bhuwan

    2017-12-14

    Cytotoxic drugs can be encapsulated in liposomes vesicles, which act as drug delivery vehicles and reduce the risk of exposure of drug to healthy cells(1). The sterility of such liposome solutions is typically ensured using 0.2μm rated sterilizing grade membranes, but due to the high viscosity and low surface tension of these formulations, they can cause pre-mature blocking and increased risk of bacterial penetration through a 0.2μm sterilizing grade membrane(2). The low surface tension of liposome solutions affects the contact angle with membrane and reduces bubble point leading to bacterial penetration through the membrane. This poses a great challenge to select an appropriate sterilizing grade membrane for a given process and for filter manufacturers to develop a sterilizing grade membrane that specifically addresses these needs. In this study, the influence of different variables that could affect the total throughput and bacterial retention performance of different membranes types on processing of liposome solutions have been evaluated. Based on the results, we conclude that the membrane properties e.g., surface porosity, surface tension, pore size, symmetry/asymmetry, hydrophilicity and liposome properties e.g., composition, lipid size and concentration affect bacterial retention and total throughput capacity. Process parameters such as temperature, pressure and flow should also be optimized to improve process efficiency. Copyright © 2017, Parenteral Drug Association.

  16. Radiation sterilization of potato starch and Sedonik

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Ismatov, N.B.; Saidov, R.P. et al.

    2016-01-01

    The raw material of pharmaceutical preparations potato starch and sedative means of Sedonik are sterilized at the electron's accelerator Electronics U-003. It is established that at 20.3 kGy absorbed dose and electron's energy 3 - 5 MeV the results of microbiological analysis showed sterility of potato starch and Sedonik and correspondence of their physical-optical properties to the requirements of normative documents. (authors)

  17. Fuel inspection device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi.

    1990-01-01

    The fuel inspection device of the present invention has a feature of obtaining an optimum illumination upon fuel rod interval inspection operation in a fuel pool. That is, an illumination main body used underwater is connected to a cable which is led out on a floor. A light control device is attached to the other end of the cable and an electric power cable is connected to the light control device. A light source (for example, incandescent lamp) is incorporated in the casing of the illumination main body, and a diffusion plate is disposed at the front to provide a plane light source. The light control device has a light control knob capable of remote-controlling the brightness of the light of the illumination main body. In the fuel inspection device thus constituted, halation is scarcely caused on the image screen upon inspection of fuels by a submerged type television camera to facilitate control upon inspection. Accordingly, efficiency of the fuel inspection can be improved to shorten the operation time. (I.S.)

  18. Mass-rearing for sterile insect release

    International Nuclear Information System (INIS)

    Parker, A.G.

    2005-01-01

    As the sterile insect technique (SIT) relies upon released sterile male insects efficiently competing with wild males to mate with wild females, it follows that mass-rearing of insects is one of the principal steps in the process. Mass-rearing for the SIT presents both problems and opportunities due to the increased scale involved compared with rearing insects for most other purposes. This chapter discusses facility design, environmental concerns, strain management, quality control, automation, diet, sex separation, marking, and storage in relation to rearing for the SIT. (author)

  19. Multilevel Perspectives on Female Sterilization in Low-Income Communities in Mumbai, India.

    Science.gov (United States)

    Brault, Marie A; Schensul, Stephen L; Singh, Rajendra; Verma, Ravi K; Jadhav, Kalpita

    2016-09-01

    Surgical sterilization is the primary method of contraception among low-income women in India. This article, using qualitative analysis of key informant, in-depth interviews, and quantitative analyses, examines the antecedents, process, and outcomes of sterilization for women in a low-income area in Mumbai, India. Family planning policies, socioeconomic factors, and gender roles constrain women's reproductive choices. Procedures for sterilization rarely follow protocol, particularly during pre-procedure counseling and consent. Women who choose sterilization often marry early, begin conceiving soon after marriage, and reach or exceed ideal family size early due to problems in accessing reversible contraceptives. Despite these constraints, this study indicates that from the perspective of women, the decision to undergo sterilization is empowering, as they have fulfilled their reproductive duties and can effectively exercise control over their fertility and sexuality. This empowerment results in little post-sterilization regret, improved emotional health, and improved sexual relationships following sterilization. © The Author(s) 2015.

  20. Practices of radiation sterilization of medical products and pharmaceutical preparations: egyptian experience

    International Nuclear Information System (INIS)

    Roushdy, H.M.

    1992-01-01

    Radiation sterilization involves the application of sufficient ionizing energy furnished by either x-rays, gamma-rays or accelerated electron beams, to render an article free of viable micro-organisms. The method offers a number of advantages which makes it an attractive choice in a number of situations: It is a suitable means of sterilizing many many materials.. Radiation causes no significant temperature rise, thus permits sterilization of heat-sensitive drugs and low melting-point plastics. It is certainly the best, and often the only method of sterilizing biological tissues and preparations of biological origin. due to its high penetrating ability, gamma-radiation reaches all parts of the object to be sterilized. The radiation sterilized products are not subjected to touching or exposure to the outside environment except by the and users. The chemical reactivity of radiation is relatively low as compared with the highly reactive gases. Radiation can be easily adapted for continuous processing as compared with batch operations currently in use with gas sterilization. The radiation process is the most reliable of all competing sterilization methods due to the obsolete certainty that the radiation source emits radiation of known energy and power

  1. Practices of radiation sterilization of medical products and pharmaceutical preparations: egyptian experience

    Energy Technology Data Exchange (ETDEWEB)

    Roushdy, H M

    1993-12-31

    Radiation sterilization involves the application of sufficient ionizing energy furnished by either x-rays, gamma-rays or accelerated electron beams, to render an article free of viable micro-organisms. The method offers a number of advantages which makes it an attractive choice in a number of situations: It is a suitable means of sterilizing many many materials.. Radiation causes no significant temperature rise, thus permits sterilization of heat-sensitive drugs and low melting-point plastics. It is certainly the best, and often the only method of sterilizing biological tissues and preparations of biological origin. due to its high penetrating ability, gamma-radiation reaches all parts of the object to be sterilized. The radiation sterilized products are not subjected to touching or exposure to the outside environment except by the and users. The chemical reactivity of radiation is relatively low as compared with the highly reactive gases. Radiation can be easily adapted for continuous processing as compared with batch operations currently in use with gas sterilization. The radiation process is the most reliable of all competing sterilization methods due to the obsolete certainty that the radiation source emits radiation of known energy and power.

  2. Effect of sterilization on the properties of CDHA-OCP-beta-TCP biomaterial

    Directory of Open Access Journals (Sweden)

    Loreley Morejón-Alonso

    2007-03-01

    Full Text Available The effect of the method of sterilization on the physical, chemical and mechanical properties of a new bone repairing material was studied. The material was obtained by thermal hydrolysis of beta-tricalcium phosphate/orthophosphoric acid cement and was composed of calcium deficient hydroxyapatite, octacalcium phosphate (OCP, and beta-tricalcium phosphate. Partial decomposition of the OCP was observed after sterilization for the three methods. Decomposition increased to the following sequence of sterilization methods: ethylene oxide; autoclaving; dry oven. On the other hand, mechanical strength decreased with regard to non sterilized material in the sterilization sequence: ethylene oxide; dry oven; autoclaving. The compressive strength was 8.5 ± 1.0; 9.0 ± 1.2; 8.2 ± 0.8 and 6.5 ± 1.0 MPa, whereas diametral tensile strength was 2.1 ± 0.3; 2.5 ± 0.1; 1.9 ± 0.9 and 1.6 ± 0.3 for the material sterilized by ethylene oxide, dry oven, and autoclaving, respectively. Several compositional and microstuctural changes were detected after dry heat and autoclave sterilization. Ethylene oxide sterilization had lesser effect on the chemical composition and strength than dry heat and autoclaving.

  3. Segregation of male-sterility alleles across a species boundary.

    Science.gov (United States)

    Weller, S G; Sakai, A K; Culley, T M; Duong, L; Danielson, R E

    2014-02-01

    Hybrid zones may serve as bridges permitting gene flow between species, including alleles influencing the evolution of breeding systems. Using greenhouse crosses, we assessed the likelihood that a hybrid zone could serve as a conduit for transfer of nuclear male-sterility alleles between a gynodioecious species and a hermaphroditic species with very rare females in some populations. Segregation patterns in progeny of crosses between rare females of hermaphroditic Schiedea menziesii and hermaphroditic plants of gynodioecious Schiedea salicaria heterozygous at the male-sterility locus, and between female S. salicaria and hermaphroditic plants from the hybrid zone, were used to determine whether male-sterility was controlled at the same locus in the parental species and the hybrid zone. Segregations of females and hermaphrodites in approximately equal ratios from many of the crosses indicate that the same nuclear male-sterility allele occurs in the parent species and the hybrid zone. These rare male-sterility alleles in S. menziesii may result from gene flow from S. salicaria through the hybrid zone, presumably facilitated by wind pollination in S. salicaria. Alternatively, rare male-sterility alleles might result from a reversal from gynodioecy to hermaphroditism in S. menziesii, or possibly de novo evolution of male sterility. Phylogenetic analysis indicates that some species of Schiedea have probably evolved separate sexes independently, but not in the lineage containing S. salicaria and S. menziesii. High levels of selfing and expression of strong inbreeding depression in S. menziesii, which together should favour females in populations, argue against a reversal from gynodioecy to hermaphroditism in S. menziesii. © 2014 The Authors. Journal of Evolutionary Biology © 2014 European Society For Evolutionary Biology.

  4. Laparoscopic tubal sterilization reversal and fertility outcomes

    Directory of Open Access Journals (Sweden)

    K Jayakrishnan

    2011-01-01

    Full Text Available Purpose: The purpose of the study was two-fold. Firstly it was to assess the suitability for tubal recanalization and factors predicting successful laparoscopic recanalization. Secondly, it was to analyze the fertility outcomes and factors affecting the pregnancy rate following laparoscopic tubal recanalization. Materials and Methods: A retrospective chart review of prospectively followed-up 29 women at a tertiary care center seeking tubal sterilization reversal between May 2005 and February 2010 were included. Results: In 14 (48.3% women unilateral tubes were suitable and in only 3 women (10.3% bilateral tubes were suitable. All cases with laparoscopic tubal sterilization were suitable, whereas all cases with fimbriectomy were unsuitable for recanalization. In 6 (20.7% cases salphingostomy was performed as an alternative procedure to tubal reanastomosis. The overall pregnancy rate was 58.8%. In cases with sterilization by Pomeroy′s method, 4 out of 10 (40% conceived, whereas for laparoscopic tubal ligation cases 6 out of 7 (85.7% conceived (P=0.32. None of the patients with final tubal length <5 cm conceived (P=0.03. Comparing the age at recanalization, in women ≤30 years, 71.4% conceived, as compared with 50% when age of women was more than 30 years (P=0.37. Conclusions: The important factors determining the success of recanalization are technique of sterilization and the remaining length of the tube after recanalization. The gynecologist must use an effective technique of sterilization to minimize the failure rates, but at the same time, which causes minimal trauma, and aim at preserving the length of the tube so that reversal is more likely to be successful, should the patient′s circumstances change.

  5. Sterilization of Microorganisms by Ozone and Ultrasound

    Science.gov (United States)

    Krasnyj, V. V.; Klosovskij, A. V.; Panasko, T. A.; Shvets, O. M.; Semenova, O. T.; Taran, V. S.; Tereshin, V. I.

    2008-03-01

    The results of recent experimental methods of sterilization of microorganisms with the use of ozone and ultrasound are presented. The main aim was to optimize the process of sterilization in water solution taking into account the ozone concentration, the power of ultrasonic emitter and the temperature of water. In the present work, the ultrasonic cavitation with simultaneous ozone generation has been used. The high ozone concentration in water solution was achieved by two-barrier glow discharge generated at atmospheric pressure and a cooling thermo-electric module. Such a sterilizer consists of ozone generator in a shape of flat electrodes covered with dielectric material and a high-voltage pulsed power supply of 250 W. The sterilization camera was equipped with ultrasonic source operated at 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. The ozone concentration in the aqueous solution was 10 mg/1, whereas the ozone concentration at the output of ozone generator was 30 mg/1. The complete inactivation of spores took 15 min. Selection of the temperature of water, the ozone concentrations and ultrasonic power allowed to determine the time necessary for destroying the row of microorganisms.

  6. The influence of sterilization on nitrogen-included ultrananocrystalline diamond for biomedical applications

    International Nuclear Information System (INIS)

    Tong, Wei; Tran, Phong A.; Turnley, Ann M.; Aramesh, Morteza; Prawer, Steven; Brandt, Milan; Fox, Kate

    2016-01-01

    Diamond has shown great potential in different biomedical applications, but the effects of sterilization on its properties have not been investigated. Here, we studied the influence of five sterilization techniques (solvent cleaning, oxygen plasma, UV irradiation, autoclave and hydrogen peroxide) on nitrogen-included ultrananocrystalline diamond. The chemical modification of the diamond surface was evaluated using X-ray photoelectron spectroscopy and water contact angle measurements. Different degrees of surface oxidation and selective sp 2 bonded carbon etching were found following all sterilization techniques, resulting in an increase of hydrophilicity. Higher viabilities of in vitro mouse 3T3 fibroblasts and rat cortical neuron cells were observed on oxygen plasma, autoclave and hydrogen peroxide sterilized diamond, which correlated with their higher hydrophilicity. By examination of apatite formation in simulated body fluid, in vivo bioactivity was predicted to be best on those surfaces which have been oxygen plasma treated and lowest on those which have been exposed to UV irradiation. The charge injection properties were also altered by the sterilization process and there appears to be a correlation between these changes and the degree of oxygen termination of the surface. We find that the modification brought by autoclave, oxygen plasma and hydrogen peroxide were most consistent with the use of N-UNCD in biological applications as compared to samples sterilized by solvent cleaning or UV exposure or indeed non-sterilized. A two-step process of sterilization by hydrogen peroxide following oxygen plasma treatment was then suggested. However, the final choice of sterilization technique will depend on the intended end application. - Highlights: • We test for the first time the effect of 5 sterilization techniques on nitrogen included ultrananocrystalline diamond. • Different degrees of surface oxidation and selective sp 2 bonded carbon etching were found to

  7. The influence of sterilization on nitrogen-included ultrananocrystalline diamond for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Wei [School of Physics, University of Melbourne, Parkville, Victoria (Australia); Tran, Phong A. [Department of Chemical and Biomolecular Engineering, University of Melbourne, Parkville, Victoria (Australia); Institute of Health and Biomedical Innovation, Queensland University of Technology, Kelvin Grove, Queensland (Australia); Turnley, Ann M. [Department of Anatomy and Neuroscience, University of Melbourne, Parkville, Victoria (Australia); Aramesh, Morteza [School of Physics, University of Melbourne, Parkville, Victoria (Australia); School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Brisbane, Queensland (Australia); Prawer, Steven [School of Physics, University of Melbourne, Parkville, Victoria (Australia); Brandt, Milan [Centre for Additive Manufacturing, School of Aerospace, Mechanical and Manufacturing Engineering, RMIT University, Melbourne, Victoria (Australia); Fox, Kate, E-mail: kate.fox@rmit.edu.au [Centre for Additive Manufacturing, School of Aerospace, Mechanical and Manufacturing Engineering, RMIT University, Melbourne, Victoria (Australia)

    2016-04-01

    Diamond has shown great potential in different biomedical applications, but the effects of sterilization on its properties have not been investigated. Here, we studied the influence of five sterilization techniques (solvent cleaning, oxygen plasma, UV irradiation, autoclave and hydrogen peroxide) on nitrogen-included ultrananocrystalline diamond. The chemical modification of the diamond surface was evaluated using X-ray photoelectron spectroscopy and water contact angle measurements. Different degrees of surface oxidation and selective sp{sup 2} bonded carbon etching were found following all sterilization techniques, resulting in an increase of hydrophilicity. Higher viabilities of in vitro mouse 3T3 fibroblasts and rat cortical neuron cells were observed on oxygen plasma, autoclave and hydrogen peroxide sterilized diamond, which correlated with their higher hydrophilicity. By examination of apatite formation in simulated body fluid, in vivo bioactivity was predicted to be best on those surfaces which have been oxygen plasma treated and lowest on those which have been exposed to UV irradiation. The charge injection properties were also altered by the sterilization process and there appears to be a correlation between these changes and the degree of oxygen termination of the surface. We find that the modification brought by autoclave, oxygen plasma and hydrogen peroxide were most consistent with the use of N-UNCD in biological applications as compared to samples sterilized by solvent cleaning or UV exposure or indeed non-sterilized. A two-step process of sterilization by hydrogen peroxide following oxygen plasma treatment was then suggested. However, the final choice of sterilization technique will depend on the intended end application. - Highlights: • We test for the first time the effect of 5 sterilization techniques on nitrogen included ultrananocrystalline diamond. • Different degrees of surface oxidation and selective sp{sup 2} bonded carbon etching were

  8. Mechanisms of male sterility in higher plants

    International Nuclear Information System (INIS)

    Ohta, Yasuo

    1982-01-01

    The mechanisms causing male sterility in higher plants were classified into two major categories: genetic and non-genetic. The former was further divided into six classes: 1) Anomality in spindle mechanism during meiosis, 2) chromosomal anomality such as haploidy, polyploidy, aneuploidy, chromosome some deficiency, inversion and reciprocal translocation, 3) presence of male sterile genes, 4) cytoplasmic abnormality, 5) the combination of some specific cytoplasm with particular genes, and 6) infections of microorganisms or viruses. Each mechanism was briefly explained, and the methods for the maintenance of parent lines for heterosis breeding and hybrid seed production were described. The non-genetic male sterility was classified into four types, which are caused by 1) low or high temperature, 2) water deficiency, 3) application of chemicals, and 4) radiation, with a brief explanation given for each of them. (Kaihara, S.)

  9. Pipe connection for high pressure and temperature loads

    International Nuclear Information System (INIS)

    Haferkamp, D.; Hodzic, A.; Paetz, E.; Stach, H.

    1976-01-01

    The patent proposes an inprovement of the clamping device for a pipe joint connecting pipelines which are subject to high pressure and temperature loads, e.g. in a nuclear power plant. This clamping device may be tightened and loosened by remote control. The proposed clamping ring consists of several segments connected with each other by hinge-type guide pins and fishplates. (UWI) [de

  10. Formation and release of non-extractable 14C-Dicamba residues in soil under sterile and non-sterile regimes

    International Nuclear Information System (INIS)

    Gevao, Bondi; Jones, Kevin C.; Semple, Kirk T.

    2005-01-01

    The role of native soil microorganisms in the formation and release of non-extractable 14 C-residues, previously treated with 14 C-Dicamba, was investigated to examine their significance to the longer-term environmental effects on non-extractable pesticide residues. A 90 d study compared the fate of Dicamba under sterile and non-sterile regimes. In addition, soils were aged for 30 d and repeatedly extracted with a 0.01 M CaCl 2 solution, to an extraction end point, to produce non-extractable residues. The extracted soil containing non-extractable residues was mixed with clean soil that had been freshly spiked with non-labeled Dicamba at 0.2 mg kg -1 to increase the bulk volume of the soil and stimulate microbial activity. Sub-samples were then introduced into microcosms to compare the extent of microbially facilitated release and mineralisation with release rates in sterile microcosms. The results show that microorganisms play a significant role in the formation and release of non-extractable Dicamba residues. The release of 14 C-activity in sterile microcosms was linked to physical mixing of the extracted soil with field soil prior to the beginning of the incubations. The released 14 C-activity may be further mineralized, reincorporated into humus, or taken up by plants or other soil inhabiting biota

  11. Delayed pulsar kicks from the emission of sterile neutrinos

    International Nuclear Information System (INIS)

    Kusenko, Alexander; Mandal, Bhabani Prasad; Mukherjee, Alok

    2008-01-01

    The observed velocities of pulsars suggest the possibility that sterile neutrinos with mass of several keV are emitted from a cooling neutron star. The same sterile neutrinos could constitute all or part of cosmological dark matter. The neutrino-driven kicks can exhibit delays depending on the mass and the mixing angle, which can be compared with the pulsar data. We discuss the allowed ranges of sterile neutrino parameters, consistent with the latest cosmological and x-ray bounds, which can explain the pulsar kicks for different delay times

  12. Comparative Transcriptomes Profiling of Photoperiod-sensitive Male Sterile Rice Nongken 58S During the Male Sterility Transition between Short-day and Long-day

    Directory of Open Access Journals (Sweden)

    Zhu Yingguo

    2011-09-01

    Full Text Available Abstract Background Photoperiod-sensitive genic male sterile (PGMS rice, Nongken 58S, was discovered in 1973. It has been widely used for the production of hybrid rice, and great achievements have been made in improving rice yields. However, the mechanism of the male sterility transition in PGMS rice remains to be determined. Results To investigate the transcriptome during the male sterility transition in PGMS rice, the transcriptome of Nongken 58S under short-day (SD and long-day (LD at the glume primordium differentiation and pistil/stamen primordium forming stages was compared. Seventy-three and 128 differentially expressed genes (DEGs were identified at the glume primordium differentiation and pistil/stamen primordium forming stages, respectively. Five and 22 genes were markedly up-regulated (≥ 5-fold, and two and five genes were considerably down-regulated (≥ 5-fold under SD during the male sterility transition. Gene ontology annotation and pathway analysis revealed that four biological processes and the circadian rhythms and the flowering pathways coordinately regulated the male sterility transition. Further quantitative PCR analysis demonstrated that the circadian rhythms of OsPRR1, OsPRR37, OsGI, Hd1, OsLHY and OsDof in leaves were obviously different between Nongken 58S and Nongken 58 under LD conditions. Moreover, both OsPRR37 and Hd1 in the inflorescence displayed differences between Nongken 58S and Nongken 58 under both LD and SD conditions. Conclusion The results presented here indicate that the transcriptome in Nongken 58S was significantly suppressed under LD conditions. Among these DEGs, the circadian rhythm and the flowering pathway were involved in the male sterility transition. Furthermore, these pathways were coordinately involved in the male sterility transition in PGMS rice.

  13. Studies of Sterile Irradiation Effects on the White-striped Fruit Fly

    International Nuclear Information System (INIS)

    Limohpasmanee, Wanitch; Tannarin, Thodsapol; Khongratarpon, Titima; Segsarnviriya, Suchada

    2011-06-01

    Full text: In general, sterile irradiation can affect vigor and mating competitiveness of the fruit flies. The objective of the experiments was to study the effects of sterile irradiation on the white-striped oriental fruit fly, Bactrocera dorsalis (Hendel), developed for sterile fly detection. A day before adult emergence, the pupae were irradiated at the dose of 90 Grays. No effects on adult emergence and flight ability were observed. However, it induced complete sterility in both sexes. Also, it decreased male mating competitiveness significantly, while increasing sexual competitiveness significantly

  14. Tissue banking and clinical research on radiation and ethylene oxide sterilization of tissue grafts

    International Nuclear Information System (INIS)

    Pe Khin

    1987-06-01

    The research works carried out in Rangoon, Burma under the Agency supported project RC4420/RB have dealt with an elucidation of the radiation interaction(s) with the species of biomolecules such as proteins, lipids, collagens, connective tissues present in the cleaned and freeze-dried non-viable tissue grafts. Radiation as a cool process furthermore effectively helps to destroy the microbial bioburden as the undesirable contaminants which may associate the tissue grafts. Radiation also concomitantly helps to suppress the tissue-specific immunogenicity. All these attributes of radiation induced effects have proved successful towards the development of a sterilization process. A series of non-viable tissue grafts, such as bone, nerve, fascia, dura, cartilage, chorion-amnion (as dressings in burn wounds) and tympanic membrane have been successfully attempted in Burma and many more possibilities seem to still remain unexplored. Radiation sterilization modality has proved as a blessing for the promotion of clinical surgical applications of tissue allografts in the corrective/reconstructive surgery on the disability cases due to diseases which accompany tissue losses. The investigator in Burma has reported on the case histories where freeze dried radiation sterilized tissue allografts have been successfully used in the osteogenic inductions (bone grafts); midear tympanoplasty; partial recovery of nerve sensation throught nerve allografts; rapid healing of high degree burn wounds through the use of amnion dressings. Besides, there have been a widespread surgical use of radiation sterilized dura and fascia as allografts. A national tissue banking facility has been established in Burma surrounding the processing and clinical utilization of tissue allografts which has involved over ten hospital centres throughout the country. Radiation induced effects on the biomolecules of clinical significance in the tissue grafts have been researched to help gain insight into a better

  15. Bilateral cornual abscess after endometrial ablation following Essure sterilization.

    NARCIS (Netherlands)

    Jansen, N.E.; Vleugels, M.P.; Kluivers, K.B.; Vierhout, M.E.

    2007-01-01

    Endometrial ablation is used extensively to treat dysfunctional bleeding. Since the introduction of Essure tubal sterilization, this permanent contraception method has been widely used. Both endometrial ablation and Essure sterilization are procedures reported to have only a few complications. We

  16. Induced pollen sterility in petunia. Mode of inheritance and tapetal behavior

    International Nuclear Information System (INIS)

    Singh, I.S.

    1975-01-01

    A study was undertaken to investigate the characteristics of different mutants for induced pollen sterility in Petunia hybrida Hort. The F 1 hybrid zygotes (TL-h 1 #female# x Sf-la #male#) were exposed to a 0.2% solution of ethyl methane sulfonate and to 0.75kR of 60 Co gamma rays. Their seeds were sown and pollen sterile plants were observed in the M 1 . The pattern of inheritance in the F 2 and the backcrosses of some selected pollen sterile M 1 mutants showed that sterility mutations had been induced. Whether the mutations are recessive or dominant is not yet known, but it has been shown that they act through the sporophytic tissues. Morphological and cytological observations on four highly sterile M 1 plants showed a similar abnormal behavior of the tapetum. The tapetum of the pollen sterile anthers was thicker, more vacuolated and did persist until a later stage than those in fertile anthers. It is suggested that the persistence of the tapetum after a certain stage blocks the trophic process required for the development of the microspore into viable pollen, and the cause of pollen abortion is sporophytic even when no inheritance of the sterility is observed [fr

  17. Implantable photonic devices for improved medical treatments

    Science.gov (United States)

    Sheinman, Victor; Rudnitsky, Arkady; Toichuev, Rakhmanbek; Eshiev, Abdyrakhman; Abdullaeva, Svetlana; Egemkulov, Talantbek; Zalevsky, Zeev

    2014-10-01

    An evolving area of biomedical research is related to the creation of implantable units that provide various possibilities for imaging, measurement, and the monitoring of a wide range of diseases and intrabody phototherapy. The units can be autonomic or built-in in some kind of clinically applicable implants. Because of specific working conditions in the live body, such implants must have a number of features requiring further development. This topic can cause wide interest among developers of optical, mechanical, and electronic solutions in biomedicine. We introduce preliminary clinical trials obtained with an implantable pill and devices that we have developed. The pill and devices are capable of applying in-body phototherapy, low-level laser therapy, blue light (450 nm) for sterilization, and controlled injection of chemicals. The pill is also capable of communicating with an external control box, including the transmission of images from inside the patient's body. In this work, our pill was utilized for illumination of the sinus-carotid zone in dog and red light influence on arterial pressure and heart rate was demonstrated. Intrabody liver tissue laser ablation and nanoparticle-assisted laser ablation was investigated. Sterilization effect of intrabody blue light illumination was applied during a maxillofacial phlegmon treatment.

  18. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: An in vitro study

    Directory of Open Access Journals (Sweden)

    Venkatasubramanian R

    2010-03-01

    Full Text Available Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  19. 9. School of radiation sterilization and hygienization - Lectures

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9 School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  20. 9. School of radiation sterilization and hygienization - Presentations

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9. School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  1. Development and Validation of Sterility Systems for Trees

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, Steve; Shevchenko, Olga; Ma, Caiping (Cathleen)

    2007-03-30

    The overall goal of this project was to develop and validate sterility systems in poplar with the ultimate goal of fulfilling the basic requirements for commercial use. For this, sterility must be complete and stable over multiple growing seasons, cause no detrimental effects on vegetative growth, and successful transformation events must be identifiable via molecular tests when trees are still juvenile. Because of the inherent difficulties in achieving and demonstrating complete sterility in trees, our approach was to study alternate sterility systems in Arabidopsis and/or early-flowering tree systems. The public benefit from this work is the capacity for containment of genes or exotic forms of trees so they can be of benefit for industry for production of wood, energy, and renewable products, while having minimal impact on wild populations of trees. We tested three methods for engineering sterility: dominant negative mutant (DNM) proteins, floral tissue ablation, and RNA interference (RNAi) to suppress the expression of several floral regulatory genes. The ultimate goal of this work was to produce a number of transgenic poplars that could be outplanted to enable future assessments of the effectiveness of these transgenic sterility methods. Our attempts to produce ablation constructs that did not interfere with tree health were partially successful. Using the poplar LEAFY gene promoter and the barnase/barstar system, we were able to regenerate plants that grew well in the greenhouse, but they showed poor health in the field. Four of seven DNM genes tested were considered promising enough, based on results in Arabidopsis, to produce transgenic poplars. Single, double, and triple RNAi genes were produced and transformed into poplar. Over all, we produced 1,964 PCR-confirmed transgenic events with 19 different kinds of sterility genes and several kinds of control genes. We propagated 5,640, 6,820, and 7,055 trees for each of three test poplar genotypes, and field

  2. Continuously Connected With Mobile IP

    Science.gov (United States)

    2002-01-01

    Cisco Systems developed Cisco Mobile Networks, making IP devices mobile. With this innovation, a Cisco router and its connected IP devices can roam across network boundaries and connection types. Because a mobile user is able to keep the same IP address while roaming, a live IP connection can be maintained without interruption. Glenn Research Center jointly tested the technology with Cisco, and is working to use it on low-earth-orbiting research craft. With Cisco's Mobile Networks functionality now available in Cisco IOS Software release 12.2(4)T, the commercial advantages and benefits are numerous. The technology can be applied to public safety, military/homeland security, emergency management services, railroad and shipping systems, and the automotive industry. It will allow ambulances, police, firemen, and the U.S. Coast Guard to stay connected to their networks while on the move. In the wireless battlefield, the technology will provide rapid infrastructure deployment for U.S. national defense. Airline, train, and cruise passengers utilizing Cisco Mobile Networks can fly all around the world with a continuous Internet connection. Cisco IOS(R) Software is a registered trademark of Cisco Systems.

  3. 'More than two': integrating biological control and sterile insects, from factory to field, and the possibility of its implementation in Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Cladera, Jorge L.; Viscarret, Mariana M.; Carabajal Paladino, Leonela Z.; Pietrek, Alejandro [Instituto de Tecnologia Agropecuaria (INTA), Castelar (Argentina). Inst. de Genetica; Soria, M. Alejandra; Ovruski, Sergio M. [Consejo Nacional de Investigaciones Cientificas y Tecnicas (PROIMI/CONICET), Tucuman (Argentina). Planta Piloto de Procesos Industrials Microbiolo

    2006-07-01

    No single control measure is able to provide full control of a pest. Integration of techniques like the sterile insect (SIT) with biological control practices (BC) should be intensively sough for. This possibility is revised here in connection with the fruit fly pest problems in Argentina. Theoretical reasons as well as practical conveniences for this integration are reviewed in this paper, the intention of which is to promote a discussion on how to approach the experimental study of the SIT+CB integration problem, i.e. how to measure the effects of each separate control measure as well as that of both acting together, in a repeatable manner. Arguments are advanced in favor of the joint production and releases of sterile fruit flies and parasitoids. (author)

  4. Stability and inheritance of photoperiod-sensitive genic male sterility in rice

    International Nuclear Information System (INIS)

    Zhu, Y.G.; Yu, J.H.

    1990-01-01

    Full text: In 1973, a photoperiod-sensitive genic male-sterile plant was discovered in Nongken 58. It is male sterile under long day conditions and fertile under short day conditions. Under the natural photoperiod in Wuhan, plants heading before September 2 are male sterile, showing typical pollen abortion. The fertility is gradually restored after September 2. About 50% of pollen grains are normal after September 6. F 1 using 30 different varieties was fertile regardless of daylength, F 2 segregated into 3 fertile: 1 sterile types under long day condition in some crosses, less clearly in other crosses. It is concluded that photoperiod depending male sterility is monogenic recessive inherited with some influence of modifier genes. Any normal variety can be used as restorer, therefore strong heterosis combinations can easily be bred. (author)

  5. Current state of low energy EB devices and its application technology

    International Nuclear Information System (INIS)

    Kinoshita, Shinobu

    2000-01-01

    This paper introduced the current state of low energy type EB (electron beam) devices with an acceleration voltage of 300 kV or below and specific application examples. As for EB devices, it introduced the ultra-compact new EB device (microbeam LV), experimental devices, and the pilot/production devices which have been recently developed by the manufacturer to which the author belongs. As the applications of low energy EB devices, it specifically introduced curing, graft polymerization, crosslinking, and sterilization/disinfection with soft electrons: (1) examples of EB curing; antistatic agents in antibacterial/antifungal property imparting processing, hard coat, printing and topcoat, high gloss/pattern transfer processing, and metal vapor deposition film, (2) example of graft polymerization; barrier imparting films, and (3) examples of crosslinking; shrinking films/tubes and foamed sheets. (A.O.)

  6. Improving the sterile sperm identification method for its implementation in the area-wide sterile insect technique program against Ceratitis capitata (Diptera: Tephritidae) in Spain

    International Nuclear Information System (INIS)

    Juan-Blasco, M.; Urbaneja, A.; San Andrés, V.; Sabater-Muñoz, B.; Castañera, P.

    2014-01-01

    The success of sterile males in area-wide sterile insect technique (aw-SIT) programs against Ceratitis capitata (Wiedemann) is currently measured by using indirect methods as the wild: sterile male ratio captured in monitoring traps. In the past decade, molecular techniques have been used to improve these methods. The development of a polymerase chain reaction-restriction fragment-length polymorphism- based method to identify the transfer of sterile sperm to wild females, the target of SIT, was considered a significant step in this direction. This method relies on identification of sperm by detecting the presence of Y chromosomes in spermathecae DNA extract complemented by the identification of the genetic origin of this sperm: Vienna-8 males or wild haplotype. However, the application of this protocol to aw-SIT programs is limited by handling time and personnel cost. The objective of this work was to obtain a high-throughput protocol to facilitate the routine measurement in a pest population of sterile sperm presence in wild females. The polymerase chain reactionrestriction fragment-length polymorphism markers previously developed were validated in Mediterranean fruit by samples collected from various locations worldwide. A laboratory protocol previously published was modified to allow for the analysis of more samples at the same time. Preservation methods and preservation times commonly used for Mediterranean fruit by female samples were assessed for their influence on the correct molecular detection of sterile sperm. This high-throughput methodology, as well as the results of sample management presented here, provide a robust, efficient, fast, and economical sterile sperm identification method ready to be used in all Mediterranean fruit by SIT programs. (author)

  7. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Junting [Univ. of Texas, Austin, TX (United States)

    2015-05-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states ve, vμ and vτ. In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ24 in the range of 10-2 eV2 < Δm412 < 1 eV2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  8. Radiation sterilization of plastic packing materials and aseptic packaging

    International Nuclear Information System (INIS)

    Tokuoka, Keiko

    1986-01-01

    In the present day of 'satiation', quality, not quantity, is emphasized for foods, the consumers being oriented toward raw and healthy foodstuff. Aseptic Packaging is excellent means of conservation. While conventionally chemicals have been used for sterilization of packing materials for aseptic packaging, the sterilization by radiation is used in part recently. The following are described : history of aseptic packaging and its features, sterilization by radiation, γ-ray sterilization of large-sized containers, the development of an aseptic packaging system using electron rays, the occurrence of offensive odors from packing materials (comparison of odors from various materials, volatile substances occurring in irradiated polyethylene, influence of film grade upon the formation of carboxylic acid, influence of the irradiation conditions upon the occurrences of volatile substances, volatile substances occurring in the irradiation of bag-in-box packing materials), changes in properties of the packing materials. (Mori, K.)

  9. The role of meiotic drive in hybrid male sterility.

    Science.gov (United States)

    McDermott, Shannon R; Noor, Mohamed A F

    2010-04-27

    Meiotic drive causes the distortion of allelic segregation away from Mendelian expected ratios, often also reducing fecundity and favouring the evolution of drive suppressors. If different species evolve distinct drive-suppressor systems, then hybrid progeny may be sterile as a result of negative interactions of these systems' components. Although the hypothesis that meiotic drive may contribute to hybrid sterility, and thus species formation, fell out of favour early in the 1990s, recent results showing an association between drive and sterility have resurrected this previously controversial idea. Here, we review the different forms of meiotic drive and their possible roles in speciation. We discuss the recent empirical evidence for a link between drive and hybrid male sterility, also suggesting a possible mechanistic explanation for this link in the context of chromatin remodelling. Finally, we revisit the population genetics of drive that allow it to contribute to speciation.

  10. Red oak borers become sterile when reared under continuous light

    Science.gov (United States)

    Jimmy R. Galford

    1975-01-01

    Red oak borers, Enaphalodes rufulus (Haldeman), reared under continuous light for 12 weeks became sterile. Sterility is thought to have been caused by light destroying vitamins essential for fertility

  11. Proceedings of 3. autumn school of radiation sterilization of medical utensils and grafts; 3. jesiennea szkola sterylizacji radiacyjnej sprzetu medycznego i przeszczepow

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The Polish experience and review of worldwide development of radiation techniques and technologies have been presented and discussed in the field of radiation sterilization of medical supplies and grafts as well as for food processing. These problems have found now in Poland industrial or pilot plant solutions. Also some technologies connected with medical utensils production from with polymeric material resistant for radiation have been developed in Poland.

  12. Proceedings of 3. autumn school of radiation sterilization of medical utensils and grafts; 3. jesiennea szkola sterylizacji radiacyjnej sprzetu medycznego i przeszczepow

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The Polish experience and review of worldwide development of radiation techniques and technologies have been presented and discussed in the field of radiation sterilization of medical supplies and grafts as well as for food processing. These problems have found now in Poland industrial or pilot plant solutions. Also some technologies connected with medical utensils production from with polymeric material resistant for radiation have been developed in Poland.

  13. Sterilization of microorganisms by the supercritical carbon dioxide micro-bubble method.

    Science.gov (United States)

    Ishikawa, H; Shimoda, M; Shiratsuchi, H; Osajima, Y

    1995-10-01

    Lactobacillus brevis and Saccharomyces cerevisiae were completely sterilized by the supercritical (SC) CO2 micro-bubble method. Gaseous (G) and liquid (LQ) CO2 were used in a similar manner to compare the sterilizing effect. Among the three treatments, the microorganisms were only effectively sterilized by the SC CO2 treatment at 25 MPa and 35 degrees C.

  14. National connected vehicle field infrastructure footprint analysis.

    Science.gov (United States)

    2014-06-01

    The fundamental premise of the connected vehicle initiative is that enabling wireless connectivity among vehicles, the infrastructure, and mobile devices will bring about transformative changes in safety, mobility, and the environmental impacts in th...

  15. Periodontal instrumentation for the general dental practitioner: Pt. 2. Management maintenance and sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Touyz, L.Z.G. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Oral Medicine and Periodontology); De Waal, J.

    1983-03-01

    The purpose of this article is to describe the management, maintenance and sterilization of periodontal instrumentation used by the general dental practitioner. The pre-sterilization, decontamination and cleaning, the sharpening of instrumentation and the packaging, identification and grouping for sterilization are discussed. Attention is also given to various techniques of sterilization, including gamma radiation.

  16. Transcriptional regulation of male-sterility in 7B-1 male-sterile tomato mutant.

    Directory of Open Access Journals (Sweden)

    Vahid Omidvar

    Full Text Available The 7B-1 tomato (Solanum lycopersicum L. cv Rutgers is a male-sterile mutant with enhanced tolerance to abiotic stress, which makes it a potential candidate for hybrid seed breeding and stress engineering. To underline the molecular mechanism regulating the male-sterility in 7B-1, transcriptomic profiles of the 7B-1 male-sterile and wild type (WT anthers were studied using mRNA sequencing (RNA-Seq. In total, 768 differentially expressed genes (DEGs were identified, including 132 up-regulated and 636 down-regulated transcripts. Gene ontology (GO enrichment analysis of DEGs suggested a general impact of the 7B-1 mutation on metabolic processes, such as proteolysis and carbohydrate catabolic process. Sixteen candidates with key roles in regulation of anther development were subjected to further analysis using qRT-PCR and in situ hybridization. Cytological studies showed several defects associated with anther development in the 7B-1 mutant, including unsynchronized anther maturation, dysfunctional meiosis, arrested microspores, defect in callose degradation and abnormal tapetum development. TUNEL assay showed a defect in programmed cell death (PCD of tapetal cells in 7B-1 anthers. The present study provides insights into the transcriptome of the 7B-1 mutant. We identified several genes with altered expression level in 7B-1 (including beta-1,3 glucanase, GA2oxs, cystatin, cysteine protease, pectinesterase, TA29, and actin that could potentially regulate anther developmental processes, such as meiosis, tapetum development, and cell-wall formation/degradation.

  17. Resonant Production of Sterile Neutrinos in the Early Universe

    Science.gov (United States)

    Gilbert, Lauren; Grohs, Evan; Fuller, George M.

    2016-06-01

    This study examines the cosmological impacts of a light resonantly produced sterile neutrino in the early universe. Such a neutrino could be produced through lepton number-driven Mikheyev-Smirnov-Wolfenstein (MSW) conversion of active neutrinos around big bang nucleosynthesis (BBN), resulting in a non-thermal spectrum of both sterile and electron neutrinos. During BBN, the neutron-proton ratio depends sensitively on the electron neutrino flux. If electron neutrinos are being converted to sterile neutrinos, this makes the n/p ratio a probe of possible new physics. We use observations of primordial Yp and D/H to place limits on this process.

  18. Sterilization studies on the adult indian meal moth, plodia interpunctella (HUBNER)

    International Nuclear Information System (INIS)

    Boshra, S.A.; Hasaballa, Z.A.

    1993-01-01

    The effects of gamma radiation doses ranging between 10 and 65 krad on adult plodia interpunctella (Hubner) were studied. Irradiation of adult affected clearly the egg production and fertility of both sexes at different mating combinations. Females were more sensitive to the sterilizing effects of gamma radiation than males. Complete sterility of females and males was achieved at 50 and 65 krad, respectively. Replacing normal males by sterile ones in the normal population decreased the egg hatch ability when compared with the control population. Newly emerged unmated females laid completely infertile eggs when confined with irradiated (65 krad) males, whether mating occurred on the day of treatment or 2 days after treatment. Sterilized males were able to compete with normal ones in a population at the highest flooding ratios. Adding sterile females to this competing population gave excellent results.5 tab

  19. Sterile neutrino search with the Double Chooz experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hellwig, Denise; Bekman, Ilja; Kampmann, Philipp; Schoppmann, Stefan; Soiron, Michael; Stahl, Achim; Wiebusch, Christopher [III. Physikalisches Institut B, RWTH Aachen (Germany)

    2016-07-01

    The Double Chooz experiment is a reactor neutrino disappearance experiment located at the Chooz nuclear power plant, France. It measures the electron-antineutrino flux of the two nuclear reactors with two detectors of identical design. A far detector at a distance of about 1 km is operating since 2011; a near detector at a distance of about 400 m is operating since the end of 2014. The combination of the two detectors offers sensitivity to sterile neutrino mixing parameters. Sterile neutrinos are neutrino mass states not taking part in weak interactions, but may mix with known neutrino states. This induces additional mixing angles and mass differences. This talk describes the search for sterile neutrinos and the sensitivity of Double Chooz to the mixing angle θ{sub 14}.

  20. Biological basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Lance, D.R.; McInnis, D.O.

    2005-01-01

    In principle, the sterile insect technique (SIT) is applicable to controlling a wide variety of insect pests, but biological factors, interacting with socio-economic and political forces, restrict its practical use to a narrower set of pest species and situations. This chapter reviews how the biology and ecology of a given pest affect the feasibility and logistics of developing and using the SIT against that pest insect. The subjects of pest abundance, distribution, and population dynamics are discussed in relation to producing and delivering sufficient sterile insects to control target populations. Pest movement and distribution are considered as factors that influence the feasibility and design of SIT projects, including the need for population- or area-wide management approaches. Biological characteristics, that affect the ability of sterile insects to interact with wild populations, are presented, including the nature of mating systems of pests, behavioural and physiological consequences of mass production and sterilization, and mechanisms that males use to block a female's acquisition and/or use of sperm from other males. An adequate knowledge of the biology of the pest species and potential target populations is needed, both for making sound decisions on whether integration of the SIT into an area-wide integrated pest management (AW-IPM) programme is appropriate, and for the efficient and effective application of the technique. (author)