  1. Stereotactic IMRT using a MMLC

    International Nuclear Information System (INIS)

    Hoban, P.; Short, R.; Biggs, D.; Rose, A.; Smee, R.; Schneider, M.

    2001-01-01

    Full text: The leaf width of the multileaf collimator (MLC) used for intensity modulated radiotherapy (IMRT ) largely determines the resolution of the intensity maps that define the entire profile of each beam. In turn it is this resolution, and consequently the achievable degree of beam modulation, that determines the ability to conform the 3D dose distribution to complex target volumes. As such, the leaf width is of more importance than in fixed-field MLC treatments where only the beam edges are affected.A Radionics micro-multileaf collimator (MMLC) with 4 mm leaf width, attached to a Siemens Primus linear accelerator, is in use for stereotactic IMRT at PbWH. Treatment planning is performed with the XPlan system including an integrated IMRT module. Cases treated have so far been with conventional fractionation, including both malignant and benign cranial lesions. Meningiomas in particular often require a complex dose distribution because of their en-plaque nature and/or proximity to the brainstem. Stereotactic localisation and fixation is with the Gill-Thomas-Cosman head-ring or Head and Neck localiser. Cases are typically planned both for fixed-field treatment and IMRT, with IMRT being used if significant benefit is seen. IMRT treatment with the Siemens MLC is also an option. A quality assurance system has been set up, including a flowchart/checklist and phantom dosimetry using TLDs. As expected, treatment plans show IMRT with the MMLC to consistently be the best option dosimetrically. In particular, for a given target coverage there is always better sparing of nearby organs at risk (OARs) with MMLC rather than MLC-based IMRT. Adjustments such as the inclusion of a margin around the target volume or an increase in the penalty for target underdosage improve coverage for MLC plans but generally at the expense of increased OAR involvement. MMLC IMRT treatments commonly require 30-50 fields and can be delivered in approximately 10-15 minutes using an autosequence

  2. Definitive Upfront Stereotactic Ablative Radiotherapy Combined with Image-Guided, Intensity Modulated Radiotherapy (IG-IMRT or IG-IMRT Alone for Locally Advanced Non-Small Cell Lung Cancer.

    Directory of Open Access Journals (Sweden)

    Alexander Chi

    Full Text Available Image-guided (IG intensity-modulated radiotherapy (IMRT enables maximal tumor margin reduction for the sparing of organs at risk (OARs when used to treat locally advanced non-small cell lung cancer (NSCLC with definitive chemo-radiation. It also allows for the incorporation of stereotactic ablative radiotherapy (SABR into the treatment regimen. Here, we describe our initial experience in combining definitive upfront SABR to the primary lesion with chemo-radiation delivered with conventionally fractionated IG-IMRT to the remaining regional disease; along with clinical outcome following chemo-radiation with conventionally fractionated IG-IMRT alone in the treatment of locally advanced NSCLC.The clinical outcome of 29 patients with locally advanced NSCLC who underwent conventionally fractionated IG-IMRT, or definitive upfront SABR followed by IG-IMRT combined with chemotherapy (induction, concurrent, or both was retrospectively reviewed.After a median follow up of 23.7 months, the median overall survival (OS and progression-free survival (PFS were 19.8 and 11.3 months, respectively. The 2 year local, regional, and distant control was 60%, 62%, and 38%, respectively. No local failure was observed in 3 patients following SABR + IG-IMRT while 6/26 patients failed locally following IG-IMRT alone. SABR + IG-IMRT was well tolerated. No ≥ grade 3 radiation-related toxicity was observed.Definitive upfront SABR followed by IG-IMRT in selected patients with locally advanced NSCLC warrants further investigation in future clinical trials, while chemo-radiation with IG-IMRT alone was well tolerated.

  3. SU-E-T-338: Dosimetric Study of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) for Stereotactic Body Radiation Therapy (SBRT) in Early Stage Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, I; Quinn, K; Seebach, A; Wang, H [OSF Saint Anthony Medical Center, Rockford, IL (United States); Yah, R [University of Illinois College of Medicine at Rockford, Rockford, IL (United States)

    2015-06-15

    Purpose: This study evaluates the dosimetric differences using volumetric modulated arc therapy (VMAT) in patients previously treated with intensity modulated radiation therapy IMRT for stereotactic body radiotherapy (SBRT) in early stage lung cancer. Methods: We evaluated 9 consecutive medically inoperable lung cancer patients at the start of the SBRT program who were treated with IMRT from November 2010 to October 2011. These patients were treated using 6 MV energy. The 9 cases were then re-planned with VMAT performed with arc therapy using 6 MV flattening filter free (FFF) energy with the same organs at risk (OARS) constraints. Data collected for the treatment plans included target coverage, beam on time, dose to OARS and gamma pass rate. Results: Five patients were T1N0 and four patients were T2N0 with all tumors less than 5 cm. The average GTV was 13.02 cm3 (0.83–40.87) and average PTV was 44.65 cm3 (14.06–118.08). The IMRT plans had a mean of 7.2 angles (6–9) and 5.4 minutes (3.6–11.1) per plan. The VMAT plans had a mean of 2.8 arcs (2–3) and 4.0 minutes (2.2–6.0) per plan. VMAT had slightly more target coverage than IMRT with average increase in D95 of 2.68% (1.24–5.73) and D99 of 3.65% (0.88–8.77). VMAT produced lower doses to all OARs. The largest reductions were in maximum doses to the spinal cord with an average reduction of 24.1%, esophagus with an average reduction of 22.1%, and lung with an average reduction in the V20 of 16.3% The mean gamma pass rate was 99.8% (99.2–100) at 3 mm and 3% for VMAT with comparable values for IMRT. Conclusion: These findings suggest that using VMAT for SBRT in early stage lung cancer is superior to IMRT in terms of dose coverage, OAR dose and a lower treatment delivery time with a similar gamma pass rate.

  4. AP-PA field orientation followed by IMRT reduces lung exposure in comparison to conventional 3D conformal and sole IMRT in centrally located lung tumors

    Directory of Open Access Journals (Sweden)

    Soyfer Viacheslav

    2012-02-01

    Full Text Available Abstract Little attention has been paid to the fact that intensity modulated radiation therapy (IMRT techniques do not easily enable treatment with opposed beams. Three treatment plans (3 D conformal, IMRT, and combined (anterior-posterior-posterio-anterior (AP-PA + IMRT of 7 patients with centrally-located lung cancer were compared for exposure of lung, spinal cord and esophagus. Combined IMRT and AP-PA techniques offer better lung tissue sparing compared to plans predicated solely on IMRT for centrally-located lung tumors.

  5. Stereotactic intensity-modulated radiation therapy (IMRT) and inverse treatment planning for advanced pleural mesothelioma. Feasibility and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Muenter, M.W.; Thilmann, C.; Hof, H.; Debus, J. [Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (dkfz), Heidelberg (Germany); Nill, S.; Hoess, A.; Partridge, M. [Dept. of Medical Physics, German Cancer Research Center (dkfz), Heidelberg (Germany); Haering, P. [Dept. of Central Dosimetry, German Cancer Research Center (dkfz), Heidelberg (Germany); Manegold, C. [Dept. of Medical Oncology/Internal Medicine, Thoraxklinik Heidelberg gGmbH, Heidelberg (Germany); Wannenmacher, M. [Dept. of Clinical Radiology, Univ. of Heidelberg, Heidelberg (Germany)

    2003-08-01

    Background and Purpose: Complex-shaped malignant pleural mesotheliomas (MPMs) with challenging volumes are extremely difficult to treat by conventional radiotherapy due to tolerance doses of the surrounding normal tissue. In a feasibility study, we evaluated if inversely planned stereotactic intensity-modulated radiation therapy (IMRT) could be applied in the treatment of MPM. Patients and Methods: Eight patients with unresectable lesions were treated after failure of chemotherapy. All patients were positioned using noninvasive patient fixation techniques which can be attached to the applied extracranial stereotactic system. Due to craniocaudal extension of the tumor, it was necessary to develop a special software attached to the inverse planning program KonRad, which can connect two inverse treatment plans and consider the applied dose of the first treatment plan in the area of the matchline of the second treatment plan. Results: Except for one patient, in whom radiotherapy was canceled due to abdominal metastasis, treatment could be completed in all patients and was well tolerated. Median survival after diagnosis was 20 months and after IMRT 6.5 months. Therefore, both the 1-year actuarial overall survival from the start of radiotherapy and the 2-year actuarial overall survival since diagnosis were 28%. IMRT did not result in clinically significant acute side effects. By using the described inverse planning software, over- or underdosage in the region of the field matchline could be prevented. Pure treatment time ranged between 10 and 21 min. Conclusion: This study showed that IMRT is feasible in advanced unresectable MPM. The presented possibilities of stereotactic IMRT in the treatment of MPM will justify the evaluation of IMRT in early-stage pleural mesothelioma combined with chemotherapy in a study protocol, in order to improve the outcome of these patients. Furthermore, dose escalation should be possible by using IMRT. (orig.)

  6. Optimization of the primary collimator settings for fractionated IMRT stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Tobler, Matt; Leavitt, Dennis D.; Watson, Gordon

    2004-01-01

    Advances in field-shaping techniques for stereotactic radiosurgery/radiotherapy have allowed dynamic adjustment of field shape with gantry rotation (dynamic conformal arc) in an effort to minimize dose to critical structures. Recent work evaluated the potential for increased sparing of dose to normal tissues when the primary collimator setting is optimized to only the size necessary to cover the largest shape of the dynamic micro multi leaf field. Intensity-modulated radiotherapy (IMRT) is now a treatment option for patients receiving stereotactic radiotherapy treatments. This multisegmentation of the dose delivered through multiple fixed treatment fields provides for delivery of uniform dose to the tumor volume while allowing sparing of critical structures, particularly for patients whose tumor volumes are less suited for rotational treatment. For these segmented fields, the total number of monitor units (MUs) delivered may be much greater than the number of MUs required if dose delivery occurred through an unmodulated treatment field. As a result, undesired dose delivered, as leakage through the leaves to tissues outside the area of interest, will be proportionally increased. This work will evaluate the role of optimization of the primary collimator setting for these IMRT treatment fields, and compare these results to treatment fields where the primary collimator settings have not been optimized

  7. Esophagus and contralateral lung-sparing IMRT for locally advanced lung cancer in the community hospital setting

    Directory of Open Access Journals (Sweden)

    Johnny eKao

    2015-06-01

    Full Text Available Background: The optimal technique for performing lung IMRT remains poorly defined. We hypothesize that improved dose distributions associated with normal tissue sparing IMRT can allow for safe dose escalation resulting in decreased acute and late toxicity. Methods: We performed a retrospective analysis of 82 consecutive lung cancer patients treated with curative intent from 1/10 to 9/14. From 1/10 to 4/12, 44 patients were treated with the community standard of 3-dimensional conformal radiotherapy or IMRT without specific esophagus or contralateral lung constraints (standard RT. From 5/12 to 9/14, 38 patients were treated with normal tissue-sparing IMRT with selective sparing of contralateral lung and esophagus. The study endpoints were dosimetry, toxicity and overall survival.Results: Despite higher mean prescribed radiation doses in the normal tissue-sparing IMRT cohort (64.5 Gy vs. 60.8 Gy, p=0.04, patients treated with normal tissue-sparing IMRT had significantly lower lung V20, V10, V5, mean lung, maximum esophagus and mean esophagus doses compared to patients treated with standard RT (p≤0.001. Patients in the normal tissue-sparing IMRT group had reduced acute grade ≥3 esophagitis (0% vs. 11%, p<0.001, acute grade ≥2 weight loss (2% vs. 16%, p=0.04, late grade ≥2 pneumonitis (7% vs. 21%, p=0.02. The 2-year overall survival was 52% with normal tissue-sparing IMRT arm compared to 28% for standard RT (p=0.015.Conclusion: These data provide proof of principle that suboptimal radiation dose distributions are associated with significant acute and late lung and esophageal toxicity that may result in hospitalization or even premature mortality. Strict attention to contralateral lung and esophageal dose volume constraints are feasible in the community hospital setting without sacrificing disease control.

  8. Hypofractionated stereotactic radiotherapy for malignant tumors of the lung

    Directory of Open Access Journals (Sweden)

    О. Ю. Аникеева

    2015-10-01

    Full Text Available Hypofractionated stereotactic radiotherapy was used for 26 patients at medically inoperable stage I of non-small cell lung cancer with dose escalation of 48-54 Gy prescribed at 90 or 95% isodose level in 3-4 fractions. Nine-months local control and cancer-specific survival were 82.0 and 66.8% respectively, with minimal toxicity. For metastatic lung tumors local control was obtained in 92% cases. Hypofractionated stereotactic radiation therapy (SBRT is safe and feasible for the treatment of inoperable primary lung cancer and single lung metastasis.

  9. Does the IMRT technique allow improvement of treatment plans (e.g. lung sparing) for lung cancer patients with small lung volume: a planning study

    International Nuclear Information System (INIS)

    Komosinska, K.; Kepka, L.; Gizynska, M.; Zawadzka, A.

    2008-01-01

    Aim: We evaluated whether intensity-modulated radiation therapy (IMRT) may offer any advantages in comparison with three-dimensional conformal radiotherapy (3D-CRT) for patients with small lung volume (SLV). Methods: Treatment planning was performed for 10 NSCLC patients with the smallest lung volume (mean: 2241 cc) among 200 patients from our database. For each patient 3D-CRT and IMRT plans were prepared. The goal was to deliver 66 Gy/33 fractions, with dose constraints: mean lung dose (MLD) < 20 Gy, V20 < 35%; spinal cord - Dmax < 45 Gy. When the plan could not meet these criteria, total dose was reduced. The 3D-CRT and IMRT plans were compared. We investigated: prescribed dose, coverage and conformity indices, MLD, V5-V65 in the lung. Results: In 4 out of 10 plans, 3D-CRT did not allow 66 Gy to be delivered, because of predicted pulmonary toxicity. These 4 cases included 3 for which we did not reach 66 Gy with IMRT; still, for these 3 plans the total dose was increased by an average of 9 Gy with IMRT in comparison with 3D-CRT. Coverage indices were similar for both techniques. Conformity indices were better for IMRT plans. MLD was lower in five IMRT and two 3D-CRT plans if equal doses were delivered. The decrease in MLD was seen for cases with large PTV and high PTV/lung volume ratio. Lung V5 was lower for all 3D-CRT plans, 47% vs. 57% for IMRT; V15 and above were larger for 3D-CRT Conclusion: In the planning study, IMRT seems to be a promising technique for cases with SLV, especially when associated with large PT V. (authors)

  10. Multiple fields may offer better esophagus sparing without increased probability of lung toxicity in optimized IMRT of lung tumors

    International Nuclear Information System (INIS)

    Chapet, Olivier; Fraass, Benedick A.; Haken, Randall K. ten

    2006-01-01

    Purpose: To evaluate whether increasing numbers of intensity-modulated radiation therapy (IMRT) fields enhance lung-tumor dose without additional predicted toxicity for difficult planning geometries. Methods and Materials: Data from 8 previous three dimensional conformal radiation therapy (3D-CRT) patients with tumors located in various regions of each lung, but with planning target volumes (PTVs) overlapping part of the esophagus, were used as input. Four optimized-beamlet IMRT plans (1 plan that used the 3D-CRT beam arrangement and 3 plans with 3, 5, or 7 axial, but predominantly one-sided, fields) were compared. For IMRT, the equivalent uniform dose (EUD) in the whole PTV was optimized simultaneously with that in a reduced PTV exclusive of the esophagus. Normal-tissue complication probability-based costlets were used for the esophagus, heart, and lung. Results: Overall, IMRT plans (optimized by use of EUD to judiciously allow relaxed PTV dose homogeneity) result in better minimum PTV isodose surface coverage and better average EUD values than does conformal planning; dose generally increases with the number of fields. Even 7-field plans do not significantly alter normal-lung mean-dose values or lung volumes that receive more than 13, 20, or 30 Gy. Conclusion: Optimized many-field IMRT plans can lead to escalated lung-tumor dose in the special case of esophagus overlapping PTV, without unacceptable alteration in the dose distribution to normal lung

  11. Superior sulcus non-small cell lung carcinoma: A comparison of IMRT and 3D-RT dosimetry.

    Science.gov (United States)

    Truntzer, Pierre; Antoni, Delphine; Santelmo, Nicola; Schumacher, Catherine; Falcoz, Pierre-Emmanuel; Quoix, Elisabeth; Massard, Gilbert; Noël, Georges

    2016-01-01

    A dosimetric study comparing intensity modulated radiotherapy (IMRT) by TomoTherapy to conformational 3D radiotherapy (3D-RT) in patients with superior sulcus non-small cell lung cancer (NSCLC). IMRT became the main technique in modern radiotherapy. However it was not currently used for lung cancers. Because of the need to increase the dose to control lung cancers but because of the critical organs surrounding the tumors, the gains obtainable with IMRT is not still demonstrated. A dosimetric comparison of the planned target and organs at risk parameters between IMRT and 3D-RT in eight patients who received preoperative or curative intent irradiation. In the patients who received at least 66 Gy, the mean V95% was significantly better with IMRT than 3D-RT (p = 0.043). IMRT delivered a lower D2% compared to 3D-RT (p = 0.043). The IH was significantly better with IMRT (p = 0.043). The lung V 5 Gy and V 13 Gy were significantly higher in IMRT than 3D-RT (p = 0.043), while the maximal dose (D max) to the spinal cord was significantly lower in IMRT (p = 0.043). The brachial plexus D max was significantly lower in IMRT than 3D-RT (p = 0.048). For patients treated with 46 Gy, no significant differences were found. Our study showed that IMRT is relevant for SS-NSCLC. In patients treated with a curative dose, it led to a reduction of the exposure of critical organs, allowing a better dose distribution in the tumor. For the patients treated with a preoperative schedule, our results provide a basis for future controlled trials to improve the histological complete response by increasing the radiation dose.

  12. Effective avoidance of a functional spect-perfused lung using intensity modulated radiotherapy (IMRT) for non-small cell lung cancer (NSCLC): An update of a planning study

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Singh, Shalini; Christian, Judith A.; Partridge, Mike; Nioutsikou, Elena; Cook, Gary; Bedford, James L.; Brada, Michael

    2009-01-01

    IMRT and 3-dimensional conformal radiotherapy (3-DCRT) plans of 25 patients with non-small cell lung (NSCLC) were compared in terms of planning target volume (PTV) coverage and sparing of functional lung (FL) defined by a SPECT perfusion scan. IMRT resulted in significant reduction of functional V 20 and mean lung dose in stage III patients with inhomogeneous hypoperfusion. If the dose to FL is shown to be the determinant of lung toxicity, IMRT would allow for effective dose escalation by specific avoidance of functional lung.

  13. Radiobiological impact of dose calculation algorithms on biologically optimized IMRT lung stereotactic body radiation therapy plans

    International Nuclear Information System (INIS)

    Liang, X.; Penagaricano, J.; Zheng, D.; Morrill, S.; Zhang, X.; Corry, P.; Griffin, R. J.; Han, E. Y.; Hardee, M.; Ratanatharathom, V.

    2016-01-01

    The aim of this study is to evaluate the radiobiological impact of Acuros XB (AXB) vs. Anisotropic Analytic Algorithm (AAA) dose calculation algorithms in combined dose-volume and biological optimized IMRT plans of SBRT treatments for non-small-cell lung cancer (NSCLC) patients. Twenty eight patients with NSCLC previously treated SBRT were re-planned using Varian Eclipse (V11) with combined dose-volume and biological optimization IMRT sliding window technique. The total dose prescribed to the PTV was 60 Gy with 12 Gy per fraction. The plans were initially optimized using AAA algorithm, and then were recomputed using AXB using the same MUs and MLC files to compare with the dose distribution of the original plans and assess the radiobiological as well as dosimetric impact of the two different dose algorithms. The Poisson Linear-Quadatric (PLQ) and Lyman-Kutcher-Burman (LKB) models were used for estimating the tumor control probability (TCP) and normal tissue complication probability (NTCP), respectively. The influence of the model parameter uncertainties on the TCP differences and the NTCP differences between AAA and AXB plans were studied by applying different sets of published model parameters. Patients were grouped into peripheral and centrally-located tumors to evaluate the impact of tumor location. PTV dose was lower in the re-calculated AXB plans, as compared to AAA plans. The median differences of PTV(D 95% ) were 1.7 Gy (range: 0.3, 6.5 Gy) and 1.0 Gy (range: 0.6, 4.4 Gy) for peripheral tumors and centrally-located tumors, respectively. The median differences of PTV(mean) were 0.4 Gy (range: 0.0, 1.9 Gy) and 0.9 Gy (range: 0.0, 4.3 Gy) for peripheral tumors and centrally-located tumors, respectively. TCP was also found lower in AXB-recalculated plans compared with the AAA plans. The median (range) of the TCP differences for 30 month local control were 1.6 % (0.3 %, 5.8 %) for peripheral tumors and 1.3 % (0.5 %, 3.4 %) for centrally located tumors. The lower

  14. WE-AB-202-04: Statistical Evaluation of Lung Function Using 4DCT Ventilation Imaging: Proton Therapy VS IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Q; Zhang, M; Chen, T; Yue, N; Zou, J [Rutgers University, New Brunswick, NJ (United States)

    2016-06-15

    Purpose: Variation in function of different lung regions has been ignored so far for conventional lung cancer treatment planning, which may lead to higher risk of radiation induced lung disease. 4DCT based lung ventilation imaging provides a novel yet convenient approach for lung functional imaging as 4DCT is taken as routine for lung cancer treatment. Our work aims to evaluate the impact of accounting for spatial heterogeneity in lung function using 4DCT based lung ventilation imaging for proton and IMRT plans. Methods: Six patients with advanced stage lung cancer of various tumor locations were retrospectively evaluated for the study. Proton and IMRT plans were designed following identical planning objective and constrains for each patient. Ventilation images were calculated from patients’ 4DCT using deformable image registration implemented by Velocity AI software based on Jacobian-metrics. Lung was delineated into two function level regions based on ventilation (low and high functional area). High functional region was defined as lung ventilation greater than 30%. Dose distribution and statistics in different lung function area was calculated for patients. Results: Variation in dosimetric statistics of different function lung region was observed between proton and IMRT plans. In all proton plans, high function lung regions receive lower maximum dose (100.2%–108.9%), compared with IMRT plans (106.4%–119.7%). Interestingly, three out of six proton plans gave higher mean dose by up to 2.2% than IMRT to high function lung region. Lower mean dose (lower by up to 14.1%) and maximum dose (lower by up to 9%) were observed in low function lung for proton plans. Conclusion: A systematic approach was developed to generate function lung ventilation imaging and use it to evaluate plans. This method hold great promise in function analysis of lung during planning. We are currently studying more subjects to evaluate this tool.

  15. Intrafraction Motion in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer: Intensity Modulated Radiation Therapy Versus Volumetric Modulated Arc Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Maddalena M.G.; Peulen, Heike M.U.; Belderbos, Josè S.A.; Sonke, Jan-Jakob, E-mail: j.sonke@nki.nl

    2016-06-01

    Purpose: Stereotactic body radiation therapy (SBRT) for early-stage inoperable non-small cell lung cancer (NSCLC) patients delivers high doses that require high-precision treatment. Typically, image guidance is used to minimize day-to-day target displacement, but intrafraction position variability is often not corrected. Currently, volumetric modulated arc therapy (VMAT) is replacing intensity modulated radiation therapy (IMRT) in many departments because of its shorter delivery time. This study aimed to evaluate whether intrafraction variation in VMAT patients is reduced in comparison with patients treated with IMRT. Methods and Materials: NSCLC patients (197 IMRT and 112 VMAT) treated with a frameless SBRT technique to a prescribed dose of 3 × 18 Gy were evaluated. Image guidance for both techniques was identical: pretreatment cone beam computed tomography (CBCT) (CBCT{sub precorr}) for setup correction followed immediately before treatment by postcorrection CBCT (CBCT{sub postcorr}) for verification. Then, after either a noncoplanar IMRT technique or a VMAT technique, a posttreatment (CBCT{sub postRT}) scan was acquired. The CBCT{sub postRT} and CBCT{sub postcorr} scans were then used to evaluate intrafraction motion. Treatment delivery times, systematic (Σ) and random (σ) intrafraction variations, and associated planning target volume (PTV) margins were calculated. Results: The median treatment delivery time was significantly reduced by 20 minutes (range, 32-12 minutes) using VMAT compared with noncoplanar IMRT. Intrafraction tumor motion was significantly larger for IMRT in all directions up to 0.5 mm systematic (Σ) and 0.7 mm random (σ). The required PTV margins for IMRT and VMAT differed by less than 0.3 mm. Conclusion: VMAT-based SBRT for NSCLC was associated with significantly shorter delivery times and correspondingly smaller intrafraction motion compared with noncoplanar IMRT. However, the impact on the required PTV margin was small.

  16. Dose distribution of IMRT and 3D-CRT on treating central non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Zhu Xiaoyang; Yu Guangwei

    2010-01-01

    3D-CRT and IMRT were used in the radiation therapy of Central Non-small-cell lung cancer (NSCLC), and the dose difference of the methods was estimated. Thirty-two patients suffering with II class NSCLC were selected. Based on CT images, each patient was given 1 3D-CRT (3 dimensional conformal radiotherapy) and 2 IMRT(intensity modulated radiation therapy) treatment plans (5 fields and 7 fields), respectively, and the dose distribution was evaluated too. The results showed that PTVD mean and the PTV max , PTVD max (%) and CI of IMRT were both higher than those of 3D-CRT, but the uniformity was not as good as 3D-CRT. All indexes of lung and spinal cord treated with IMRT were lower than that treated with 3D-CRT. Moreover, there was no significance of the difference between 5 fields and 7 fields. In a conclusion, IMRT could not only decrease the target dose of NSCLC, but it can protect normal tissue from radiation damage effectively. And when IMRT was used, 5 fields might be enough. (authors)

  17. Radiochromic film for individual patient QA in extracranial stereotactic lung radiotherapy

    International Nuclear Information System (INIS)

    Kron, T.; Clements, N.; Aarons, Y.; Dunn, L.; Chesson, B.; Miller, J.; Roozen, K.; Ball, D.

    2011-01-01

    Introduction: Modern radiotherapy is characterised by increasingly complex radiation delivery such as Intensity Modulated Radiation Therapy (IMRT) or extracranial stereotactic radiotherapy (ESR). It has become common practice to verify the delivery for each patient in IMRT, however, no such methods have been defined to date for ESR. It was the aim of the present work to develop a method to verify the dose distribution for ESR in a moving phantom using radiochromic film. Methods: Radiochromic film (ISP EBT2) was used in a cylindrical film cassette fitted into a QUASAR phantom (Modus Medical). The cassette can be moved forwards and backwards with motion patterns that can mimic the breathing of individual patients. The radiotherapy treatment plans of four patients were re-planned for the phantom. Between 8 and 10 radiation fields of 6 MV photons from a Varian Trilogy linear accelerator were used to deliver target doses between 18 and 26 Gy per fraction. In order to allow for measurements with EBT2 film all monitor units were divided by 3 or 4 resulting in maximum doses not exceeding 10 Gy. The film was evaluated using a transmission scan on an Epson Perfection V700 scanner with 50 dpi spatial resolution (3 colors, 48bit). A calibration curve was used to convert either the red or green component of the scan to dose. Results: Qualitative film analysis found no discernible discrepancies from planned isodose distributions in the stationary images. The dose distribution in the moving phantom was used successfully to confirm the appropriateness of the ITV construction in the planning process. Conclusions: We have developed a QA procedure that accounts for breathing patterns of individual patients in ESR for lung cancer. Radiochromic film was found to be easy to adapt to this process.

  18. Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: Effect on target and normal-structure dose-volume metrics

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Mara W. [Broad Institute of MIT and Harvard, Cambridge, MA (United States); Department of Physics, Brandeis University, Waltham, MA (United States); Kato, Catherine M. [Macalester College, St. Paul, MN (United States); Carson, Kelly M.P. [The University of North Carolina, Chapel Hill, NC (United States); Matsunaga, Nathan M. [Santa Clara University, Santa Clara, CA (United States); Arao, Robert F. [Department of Public Health and Preventive Medicine, Oregon Health and Science University, Portland, OR (United States); Doss, Emily J. [Department of Internal Medicine, Providence St. Vincent Medical Center, Portland, OR (United States); McCracken, Charles L. [Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States); Meng, Lu Z. [Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, CA (United States); Chen, Yiyi [Department of Public Health and Preventive Medicine, Oregon Health and Science University, Portland, OR (United States); Laub, Wolfram U.; Fuss, Martin [Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States); Department of Nuclear Engineering and Radiation Health Physics, Oregon State University, Corvallis, OR (United States); Tanyi, James A., E-mail: tanyij@ohsu.edu [Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States); Department of Nuclear Engineering and Radiation Health Physics, Oregon State University, Corvallis, OR (United States)

    2013-01-01

    To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non–small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: IMRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60 Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose ∼ 150% PD) for a 6-MV photon beam. Plan conformality, R{sub 50} (ratio of volume circumscribed by the 50% isodose line and the PTV), and D{sub 2} {sub cm} (D{sub max} at a distance ≥2 cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD]) and percent V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} Gy were assessed. Spinal cord and esophagus D{sub max} and D{sub 5}/D{sub 50} were computed. Chest wall (CW) D{sub max} and absolute V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} {sub Gy} were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and V{sub 10}/V{sub 5} {sub Gy}, as well as contralateral CW D{sub max} and V{sub 10}/V{sub 5} {sub Gy} (all p < 0.001). Nominal reductions of D{sub max} and D{sub 5}/D{sub 50} for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, R{sub 50} significantly improved with IMRT

  19. Proton beam therapy in non-small cell lung cancer: state of the art

    Directory of Open Access Journals (Sweden)

    Harada H

    2017-08-01

    Full Text Available Hideyuki Harada, Shigeyuki Murayama Radiation and Proton Therapy Center, Shizuoka Cancer Center Hospital, Nagaizumi, Shizuoka, Japan Abstract: This review summarizes the past and present status of proton beam therapy (PBT for lung cancer. PBT has a unique characteristic called the Bragg peak that enables a reduction in the dose of normal tissue around the tumor, but is sensitive to the uncertainties of density changes. The heterogeneity in electron density for thoracic lesions, such as those in the lung and mediastinum, and tumor movement according to respiration necessitates respiratory management for PBT to be applied in lung cancer patients. There are two types of PBT – a passively scattered approach and a scanning approach. Typically, a passively scattered approach is more robust for respiratory movement and a scanning approach could result in a more conformal dose distribution even when the tumor shape is complex. Large tumors of centrally located lung cancer may be more suitably irradiated than with intensity-modulated radiotherapy (IMRT or stereotactic body radiotherapy (SBRT. For a locally advanced lung cancer, PBT can spare the lung and heart more than photon IMRT. However, no randomized controlled trial has reported differences between PBT and IMRT or SBRT for early-stage and locally advanced lung cancers. Therefore, a well-designed controlled trial is warranted. Keywords: proton beam therapy, non-small cell lung cancer, survival, SBRT, IMRT

  20. Time evolution of regional CT density changes in normal lung after IMRT for NSCLC

    International Nuclear Information System (INIS)

    Bernchou, Uffe; Schytte, Tine; Bertelsen, Anders; Bentzen, Søren M.; Hansen, Olfred; Brink, Carsten

    2013-01-01

    Purpose: This study investigates the clinical radiobiology of radiation induced lung disease in terms of regional computed tomography (CT) density changes following intensity modulated radiotherapy (IMRT) for non-small-cell lung cancer (NSCLC). Methods: A total of 387 follow-up CT scans in 131 NSCLC patients receiving IMRT to a prescribed dose of 60 or 66 Gy in 2 Gy fractions were analyzed. The dose-dependent temporal evolution of the density change was analyzed using a two-component model, a superposition of an early, transient component and a late, persistent component. Results: The CT density of healthy lung tissue was observed to increase significantly (p 12 months. Conclusions: The radiobiology of lung injury may be analyzed in terms of CT density change. The initial transient change in density is consistent with radiation pneumonitis, while the subsequent stabilization of the density is consistent with pulmonary fibrosis

  1. SU-C-BRA-07: Virtual Bronchoscopy-Guided IMRT Planning for Mapping and Avoiding Radiation Injury to the Airway Tree in Lung SAbR

    Energy Technology Data Exchange (ETDEWEB)

    Sawant, A; Modiri, A; Bland, R; Yan, Y; Ahn, C; Timmerman, R [University of Texas SouthWestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: Post-treatment radiation injury to central and peripheral airways is a potentially important, yet under-investigated determinant of toxicity in lung stereotactic ablative radiotherapy (SAbR). We integrate virtual bronchoscopy technology into the radiotherapy planning process to spatially map and quantify the radiosensitivity of bronchial segments, and propose novel IMRT planning that limits airway dose through non-isotropic intermediate- and low-dose spillage. Methods: Pre- and ∼8.5 months post-SAbR diagnostic-quality CT scans were retrospectively collected from six NSCLC patients (50–60Gy in 3–5 fractions). From each scan, ∼5 branching levels of the bronchial tree were segmented using LungPoint, a virtual bronchoscopic navigation system. The pre-SAbR CT and the segmented bronchial tree were imported into the Eclipse treatment planning system and deformably registered to the planning CT. The five-fraction equivalent dose from the clinically-delivered plan was calculated for each segment using the Universal Survival Curve model. The pre- and post-SAbR CTs were used to evaluate radiation-induced segmental collapse. Two of six patients exhibited significant segmental collapse with associated atelectasis and fibrosis, and were re-planned using IMRT. Results: Multivariate stepwise logistic regression over six patients (81 segments) showed that D0.01cc (minimum point dose within the 0.01cc receiving highest dose) was a significant independent factor associated with collapse (odds-ratio=1.17, p=0.010). The D0.01cc threshold for collapse was 57Gy, above which, collapse rate was 45%. In the two patients exhibiting segmental collapse, 22 out of 32 segments showed D0.01cc >57Gy. IMRT re-planning reduced D0.01cc below 57Gy in 15 of the 22 segments (68%) while simultaneously achieving the original clinical plan objectives for PTV coverage and OAR-sparing. Conclusion: Our results indicate that the administration of lung SAbR can Result in significant injury to

  2. Clinical outcomes of a phase I/II study of 48 Gy of stereotactic body radiotherapy in 4 fractions for primary lung cancer using a stereotactic body frame

    International Nuclear Information System (INIS)

    Nagata, Yasushi; Takayama, Kenji; Matsuo, Yukinori; Norihisa, Yoshiki; Mizowaki, Takashi; Sakamoto, Takashi; Sakamoto, Masato; Mitsumori, Michihide; Shibuya, Keiko; Araki, Norio; Yano, Shinsuke; Hiraoka, Masahiro

    2005-01-01

    Purpose: To evaluate the clinical outcomes of 48 Gy of three-dimensional stereotactic radiotherapy in four fractions for treating Stage I lung cancer using a stereotactic body frame. Methods and Materials: Forty-five patients who were treated between September 1998 and February 2004 were included in this study. Thirty-two patients had Stage IA lung cancer, and the other 13 had Stage IB lung cancer where tumor size was less than 4 cm in diameter. Three-dimensional treatment planning using 6-10 noncoplanar beams was performed to maintain the target dose homogeneity and to decrease the irradiated lung volume >20 Gy. All patients were irradiated using a stereotactic body frame and received four single 12 Gy high doses of radiation at the isocenter over 5-13 (median = 12) days. Results: Seven tumors (16%) completely disappeared after treatment (CR) and 38 tumors (84%) decreased in size by 30% or more (PR). Therefore, all tumors showed local response. During the follow-up of 6-71 (median = 30) months, no pulmonary complications greater than an National Cancer Institute-Common Toxicity Criteria of Grade 3 were noted. No other vascular, cardiac, esophageal, or neurologic toxicities were encountered. Forty-four (98%) of 45 tumors were locally controlled during the follow-up period. However, regional recurrences and distant metastases occurred in 3 and 5 of T1 patients and zero and 4 of T2 patients, respectively. For Stage IA lung cancer, the disease-free survival and overall survival rates after 1 and 3 years were 80% and 72%, and 92% and 83%, respectively, whereas for Stage IB lung cancer, the disease-free survival and overall survival rates were 92% and 71%, and 82% and 72%, respectively. Conclusion: Forty-eight Gy of 3D stereotactic radiotherapy in 4 fractions using a stereotactic body frame is useful for the treatment of Stage I lung tumors

  3. Primary lung sarcoma treated with stereotactic ablative radiotherapy: a case report

    Directory of Open Access Journals (Sweden)

    Yeo SG

    2017-07-01

    Full Text Available Seung-Gu Yeo Department of Radiation Oncology, Soonchunhyang University College of Medicine, Soonchunhyang University Hospital, Cheonan, Republic of Korea Abstract: Primary lung sarcoma (PLS is an extremely rare, very aggressive malignancy. Surgical removal is considered the treatment of choice, and patients who have been given conventional radiotherapy have had inferior outcomes. This study is the first describing a case of PLS treated with stereotactic ablative radiotherapy (SABR, which precisely targets a small tumor with a markedly higher biologically effective dose than conventional radiotherapy. The patient was an 82-year-old man who was diagnosed with primary lung leiomyosarcoma based on radiology, pathology, and immunohistochemical examinations. The PLS was located in the right lower lobe and measured 2.5 cm. No regional nodal or distant organ metastasis was observed. He was inoperable medically. The SABR was performed using volumetric modulated arc therapy and a dose of 56 Gy in four fractions. Follow-up computed tomography 2 months after SABR revealed a complete tumor response. The toxicity was limited to mild respiratory symptoms. The patient is alive and has had no evidence of disease for 2 years. This study suggests that SABR can be a safe and effective treatment option for PLS. Keywords: primary lung sarcoma, leiomyosarcoma, stereotactic ablative radiotherapy, stereotactic body radiotherapy, radiation therapy, sarcoma 

  4. SU-F-T-356: DosimetricComparison of VMAT Vs Step and Shoot IMRT Plans for Stage III Lung CancerPatients with Mediastinal Involvement

    Energy Technology Data Exchange (ETDEWEB)

    Pearson, D; Bogue, J [University of Toledo, Toledo, OH (United States)

    2016-06-15

    Purpose: For Stage III lung cancers that entail treatment of some or all of the mediastinum, anterior-posterior focused Step and Shoot IMRT (SS-IMRT) and VMAT plans have been clinically used to deliver the prescribed dose while working to minimize lung dose and avoid other critical structures. A comparison between the two planning methods was completed to see which treatment method is superior and minimizes dose to healthy lung tissue. Methods: Ten patients who were recently treated with SS-IMRT or VMAT plans for Stage III lung cancer with mediastinal involvement were selected. All patients received a simulation CT for treatment planning, as well as a 4D CT and PET/CT fusion for target delineation. Plans were prescribed 6250 cGy in 25 fractions and normalized such that 100% of the prescription dose covered 95% of the PTV. Clinically approved SS-IMRT or VMAT plans were then copied and planned using the alternative modality with identical optimization criteria. SS-IMRT plans utilized seven to nine beams distributed around the patient while the VMAT plans consisted of two full 360 degree arcs. Plans were compared for the lung volume receiving 20 Gy (V20). Results: Both SS-IMRT and VMAT can be used to achieve clinical treatment plans for patients with Stage III Lung cancer with targets encompassing the mediastinum. VMAT plans produced an average V20 of 23.0+/−8.3% and SS-IMRT produced an average of 24.2+/−10.0%. Conclusion: Results indicate that either method can achieve comparable dose distributions, however, VMAT can allow the optimizer to distribute dose over paths of minimal lung tissue and reduce the V20. Therefore, creating a VMAT with constraints identical to an SS-IMRT plan could help to reduce the V20 in clinical treatment plans.

  5. SU-F-T-356: DosimetricComparison of VMAT Vs Step and Shoot IMRT Plans for Stage III Lung CancerPatients with Mediastinal Involvement

    International Nuclear Information System (INIS)

    Pearson, D; Bogue, J

    2016-01-01

    Purpose: For Stage III lung cancers that entail treatment of some or all of the mediastinum, anterior-posterior focused Step and Shoot IMRT (SS-IMRT) and VMAT plans have been clinically used to deliver the prescribed dose while working to minimize lung dose and avoid other critical structures. A comparison between the two planning methods was completed to see which treatment method is superior and minimizes dose to healthy lung tissue. Methods: Ten patients who were recently treated with SS-IMRT or VMAT plans for Stage III lung cancer with mediastinal involvement were selected. All patients received a simulation CT for treatment planning, as well as a 4D CT and PET/CT fusion for target delineation. Plans were prescribed 6250 cGy in 25 fractions and normalized such that 100% of the prescription dose covered 95% of the PTV. Clinically approved SS-IMRT or VMAT plans were then copied and planned using the alternative modality with identical optimization criteria. SS-IMRT plans utilized seven to nine beams distributed around the patient while the VMAT plans consisted of two full 360 degree arcs. Plans were compared for the lung volume receiving 20 Gy (V20). Results: Both SS-IMRT and VMAT can be used to achieve clinical treatment plans for patients with Stage III Lung cancer with targets encompassing the mediastinum. VMAT plans produced an average V20 of 23.0+/−8.3% and SS-IMRT produced an average of 24.2+/−10.0%. Conclusion: Results indicate that either method can achieve comparable dose distributions, however, VMAT can allow the optimizer to distribute dose over paths of minimal lung tissue and reduce the V20. Therefore, creating a VMAT with constraints identical to an SS-IMRT plan could help to reduce the V20 in clinical treatment plans.

  6. A review of stereotactic body radiotherapy – is volumetric modulated arc therapy the answer?

    International Nuclear Information System (INIS)

    Sapkaroski, Daniel; Osborne, Catherine; Knight, Kellie A

    2015-01-01

    Stereotactic body radiotherapy (SBRT) is a high precision radiotherapy technique used for the treatment of small to moderate extra-cranial tumours. Early studies utilising SBRT have shown favourable outcomes. However, major disadvantages of static field SBRT include long treatment times and toxicity complications. Volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT) may potentially mitigate these disadvantages. This review aims to assess the feasibility of emerging VMAT and IMRT-based SBRT treatment techniques and qualify which offers the best outcome for patients, whilst identifying any emerging and advantageous SBRT planning trends. A review and synthesis of data from current literature up to September 2013 was conducted on EMBASE, Medline, PubMed, Science Direct, Proquest central, Google Scholar and the Cochrane Database of Systematic reviews. Only full text papers comparing VMAT and or IMRT and or Static SBRT were included. Ten papers were identified that evaluated the results of VMAT/IMRT SBRT. Five related to medically inoperable stage 1 and 2 non-small-cell lung cancer (NSCLC), three to spinal metastasis, one related to abdominal lymph node malignancies, with the final one looking at pancreatic adenocarcinoma. Overall treatment times with VMAT were reduced by 66–70% for lung, 46–58% for spine, 42% and 21% for lymph node and pancreatic metastasis respectively, planning constraints were met with several studies showing improved organs at risk sparing with IMRT/VMAT to static SBRT. Both IMRT and VMAT were able to meet all planning constraints in the studies reviewed, with VMAT offering the greatest treatment efficiency. Early clinical outcomes with VMAT and IMRT SBRT have demonstrated excellent local control and favourable survival outcomes

  7. A review of stereotactic body radiotherapy – is volumetric modulated arc therapy the answer?

    Energy Technology Data Exchange (ETDEWEB)

    Sapkaroski, Daniel, E-mail: daniel.sapkaroski@gmail.com; Osborne, Catherine; Knight, Kellie A [Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, School of Biomedical Sciences, Monash University, Clayton, Vic. (Australia)

    2015-06-15

    Stereotactic body radiotherapy (SBRT) is a high precision radiotherapy technique used for the treatment of small to moderate extra-cranial tumours. Early studies utilising SBRT have shown favourable outcomes. However, major disadvantages of static field SBRT include long treatment times and toxicity complications. Volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT) may potentially mitigate these disadvantages. This review aims to assess the feasibility of emerging VMAT and IMRT-based SBRT treatment techniques and qualify which offers the best outcome for patients, whilst identifying any emerging and advantageous SBRT planning trends. A review and synthesis of data from current literature up to September 2013 was conducted on EMBASE, Medline, PubMed, Science Direct, Proquest central, Google Scholar and the Cochrane Database of Systematic reviews. Only full text papers comparing VMAT and or IMRT and or Static SBRT were included. Ten papers were identified that evaluated the results of VMAT/IMRT SBRT. Five related to medically inoperable stage 1 and 2 non-small-cell lung cancer (NSCLC), three to spinal metastasis, one related to abdominal lymph node malignancies, with the final one looking at pancreatic adenocarcinoma. Overall treatment times with VMAT were reduced by 66–70% for lung, 46–58% for spine, 42% and 21% for lymph node and pancreatic metastasis respectively, planning constraints were met with several studies showing improved organs at risk sparing with IMRT/VMAT to static SBRT. Both IMRT and VMAT were able to meet all planning constraints in the studies reviewed, with VMAT offering the greatest treatment efficiency. Early clinical outcomes with VMAT and IMRT SBRT have demonstrated excellent local control and favourable survival outcomes.

  8. A potential to reduce pulmonary toxicity: The use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Christian, Judith A.; Partridge, Mike; Niotsikou, Elena; Cook, Gary; Parker, Michelle; Bedford, James L.; Brada, Michael

    2007-01-01

    Background and purpose: The study aimed to examine specific avoidance of functional lung (FL) defined by a single photon emission computerized tomography (SPECT) lung perfusion scan, using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3-DCRT) in patients with non-small cell lung cancer (NSCLC). Materials and methods: Patients with NSCLC underwent planning computerized tomography (CT) and lung perfusion SPECT scan in the treatment position using fiducial markers to allow co-registration in the treatment planning system. Radiotherapy (RT) volumes were delineated on the CT scan. FL was defined using co-registered SPECT images. Two inverse coplanar RT plans were generated for each patient: 4-field 3-DCRT and 5-field step-and-shoot IMRT. 3-DCRT plans were created using automated AutoPlan optimisation software, and IMRT plans were generated employing Pinnacle 3 treatment planning system (Philips Radiation Oncology Systems). All plans were prescribed to 64 Gy in 32 fractions using data for the 6 MV beam from an Elekta linear accelerator. The objectives for both plans were to minimize the volume of FL irradiated to 20 Gy (fV 20 ) and dose variation within the planning target volume (PTV). A spinal cord dose was constrained to 46 Gy. Volume of PTV receiving 90% of the prescribed dose (PTV 90 ), fV 20 , and functional mean lung dose (fMLD) were recorded. The PTV 90 /fV 20 ratio was used to account for variations in both measures, where a higher value represented a better plan. Results: Thirty-four RT plans of 17 patients with stage I-IIIB NSCLC suitable for radical RT were analysed. In 6 patients with stage I-II disease there was no improvement in PTV 90 , fV 20 , PTV/fV 20 ratio and fMLD using IMRT compared to 3-DCRT. In 11 patients with stage IIIA-B disease, the PTV was equally well covered with IMRT and 3-DCRT plans, with IMRT producing better PTV 90 /fV 20 ratio (mean ratio - 7.2 vs. 5.3, respectively, p = 0.001) and reduced f

  9. Stereotactic radiotherapy for non-small cell lung cancer: From concept to clinical reality. 2011 update

    International Nuclear Information System (INIS)

    Girard, N.; Mornex, F.

    2011-01-01

    Only 60% of patients with early-stage non-small cell lung cancer (NSCLC), a priori bearing a favorable prognosis, undergo radical resection because of the very frequent co-morbidities occurring in smokers, precluding surgery to be safely performed. Stereotactic radiotherapy consists of the use of multiple radiation micro-beams, allowing high doses of radiation to be delivered to the tumour (ranging from 7.5 to 20 Gy per fraction) in a small number of fractions (one to eight on average). Several studies with long-term follow-up are now available, showing the effectiveness of stereotactic radiotherapy to control stage I/II non-small cell lung cancer in medically inoperable patients. Local control rates are consistently reported to be above 95% with a median survival of 34 to 45 months. Because of these excellent results, stereotactic radiation therapy is now being evaluated in operable patients in several randomized trials with a surgical arm. Ultimately, the efficacy of stereotactic radiotherapy in early-stage tumours leads to hypothesize that it may represent an opportunity for locally-advanced tumors. The specific toxicities of stereotactic radiotherapy mostly correspond to radiation-induced chest wall side effects, especially for peripheral tumours. The use of adapted fractionation schemes has made feasible the use of stereotactic radiotherapy to treat proximal tumours. Overall, from a technical concept to the availability of specific treatment devices and the publication of clinical results, stereotactic radiotherapy represents a model of implementation in thoracic oncology. (authors)

  10. A dose planning study on applicator guided stereotactic IMRT boost in combination with 3D MRI based brachytherapy in locally advanced cervical cancer

    International Nuclear Information System (INIS)

    Assenholt, Marianne S.; Petersen, Joergen B.; Nielsen, Soeren K.; Lindegaard, Jacob C.; Tanderup, Kari

    2008-01-01

    Purpose. Locally advanced cervical cancer is usually treated with external beam radiotherapy followed by brachytherapy (BT). However, if response or tumour topography is unfavourable it may be difficult to reach a sufficient BT dose. The purpose of this study was to explore whether an applicator guided stereotactic IMRT boost could be combined with brachytherapy to improve dose volume parameters. Material and methods. Dose plans of 6 patients with HR CTV volumes of 31-100cc at the time of BT were analysed. MRI was performed with a combined intracavitary (IC)-interstitial (IS) ring applicator in situ. A radiotherapy schedule consisting of 45Gy (1.8Gyx25) IMRT followed by boost of 28Gy (7Gyx4fx) was modelled. Four different boost techniques were evaluated: IC-BT, IC/IS-BT, IC-BT+IMRT and IMRT. Dose plans were optimised for maximal tumour dose (D90) and coverage (V85Gy) while respecting DVH constraints in organs at risk: D2cc <75Gy in rectum and sigmoid and <90Gy in bladder (EQD2). In combined BT+IMRT dose plans, the IMRT plan was optimised on top of the BT dose distribution. Volumes irradiated to more than 60 Gy EQD2 (V60Gy) were evaluated. Results. Median dose coverage in IC plans was 74% [66-93%]. By using IC/IS or IC-BT+IMRT boost, the median coverage was improved to 95% [78-99%], and to 96% [69-99%] respectively. For IMRT alone, a median coverage of 98% [90-100%] was achieved, but V60Gy volumes were significantly increased by a median factor of 2.0 [1.4-2.3] as compared to IC/IS. It depended on the individual tumour topography whether IC/IS-BT or IC-BT+IMRT boost was the most favourable technique. Conclusion. It is technically possible to create dose plans that combine image guided BT and IMRT. In this study the dose coverage could be significantly increased by adding IS-BT or IMRT boost to the intracavitary dose. Using IMRT alone for boost cannot be advocated since this results in a significant increase of the volume irradiated to 60Gy

  11. Investigating the impact of treatment delivery uncertainties on treatment effectiveness for lung SABR

    DEFF Research Database (Denmark)

    Blake, Samuel J.; Arumugam, Sankar; Holloway, Lois

    2017-01-01

    To quantify the impact of treatment delivery uncertainties on lung stereotactic ablative body radiotherapy (SABR) plans for step-and-shoot intensity-modulated radiotherapy (ssIMRT) and volumetric modulated arc therapy (VMAT). Baseline ssIMRT and VMAT treatment plans were generated for a cohort...... of 18 lung SABR patients. Modified plans were generated for each baseline plan by systematically varying gantry and collimator angles between − 5 and + 5 degrees, as well as multi-leaf collimator (MLC) leaf position errors of magnitude between 1 and 5 mm in both directions (i.e. leaf banks shifted...... either in the same (Type 1) or opposite (Type 2) directions). Planning target volume (PTV), spinal cord and healthy lung dose-volume histogram (DVH) metrics were compared between the modified and baseline plans. Collimator and gantry angle uncertainties did not significantly impact any of the PTV DVH...

  12. Stereotactic body radiotherapy in lung cancer: an update

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Carlos Eduardo Cintra Vita; Ferreira, Paula Pratti Rodrigues; Moraes, Fabio Ynoe de; Neves Junior, Wellington Furtado Pimenta; Carvalho, Heloisa de Andrade, E-mail: heloisa.carvalho@hc.fm.usp.br [Hospital Sirio-Libanes, Sao Paulo, SP (Brazil). Departamento de Radioterapia; Gadia, Rafael [Hospital Sirio-Libanes, Brasilia, DF (Brazil). Departamento de Radioterapia; Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Departamento de Radiologia e Oncologia. Servico de Radioterapia

    2015-07-15

    For early-stage lung cancer, the treatment of choice is surgery. In patients who are not surgical candidates or are unwilling to undergo surgery, radiotherapy is the principal treatment option. Here, we review stereotactic body radiotherapy, a technique that has produced quite promising results in such patients and should be the treatment of choice, if available. We also present the major indications, technical aspects, results, and special situations related to the technique. (author)

  13. Complications from Stereotactic Body Radiotherapy for Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kylie H. [School of Medicine, Case Western Reserve University, Cleveland, OH 44106 (United States); Okoye, Christian C.; Patel, Ravi B. [Department of Radiation Oncology, University Hospitals Seidman Cancer Center, Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106 (United States); Siva, Shankar [Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne, Victoria 3002 (Australia); Biswas, Tithi; Ellis, Rodney J.; Yao, Min; Machtay, Mitchell; Lo, Simon S., E-mail: Simon.Lo@uhhospitals.org [Department of Radiation Oncology, University Hospitals Seidman Cancer Center, Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106 (United States)

    2015-06-15

    Stereotactic body radiotherapy (SBRT) has become a standard treatment option for early stage, node negative non-small cell lung cancer (NSCLC) in patients who are either medically inoperable or refuse surgical resection. SBRT has high local control rates and a favorable toxicity profile relative to other surgical and non-surgical approaches. Given the excellent tumor control rates and increasing utilization of SBRT, recent efforts have focused on limiting toxicity while expanding treatment to increasingly complex patients. We review toxicities from SBRT for lung cancer, including central airway, esophageal, vascular (e.g., aorta), lung parenchyma (e.g., radiation pneumonitis), and chest wall toxicities, as well as radiation-induced neuropathies (e.g., brachial plexus, vagus nerve and recurrent laryngeal nerve). We summarize patient-related, tumor-related, dosimetric characteristics of these toxicities, review published dose constraints, and propose strategies to reduce such complications.

  14. Complications from Stereotactic Body Radiotherapy for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kylie H. Kang

    2015-06-01

    Full Text Available Stereotactic body radiotherapy (SBRT has become a standard treatment option for early stage, node negative non-small cell lung cancer (NSCLC in patients who are either medically inoperable or refuse surgical resection. SBRT has high local control rates and a favorable toxicity profile relative to other surgical and non-surgical approaches. Given the excellent tumor control rates and increasing utilization of SBRT, recent efforts have focused on limiting toxicity while expanding treatment to increasingly complex patients. We review toxicities from SBRT for lung cancer, including central airway, esophageal, vascular (e.g., aorta, lung parenchyma (e.g., radiation pneumonitis, and chest wall toxicities, as well as radiation-induced neuropathies (e.g., brachial plexus, vagus nerve and recurrent laryngeal nerve. We summarize patient-related, tumor-related, dosimetric characteristics of these toxicities, review published dose constraints, and propose strategies to reduce such complications.

  15. Stability of percutaneously implanted markers for lung stereotactic radiotherapy

    DEFF Research Database (Denmark)

    Persson, Gitte Bjørnsen Fredberg; Josipovic, Mirjana; Von Der Recke, Peter

    2013-01-01

    The purpose of this study was to evaluate the stability of complex markers implanted into lung tumors throughout a course of stereotactic body radiotherapy (SBRT). Fifteen patients referred for lung SBRT were prospectively included. Radio-opaque markers were implanted percutaneously, guided...... mm in one or more registrations throughout the SBRT course. This is the first study to evaluate stability of complex markers implanted percutaneously into lung tumors for image guidance in SBRT. We conclude that the observed stability of marker position within the tumor indicates that complex markers...... can be used as surrogates for tumor position during a short course of SBRT as long as the uncertainties related to their position within the tumor are incorporated into the planning target volume....

  16. Restricted Field IMRT Dramatically Enhances IMRT Planning for Mesothelioma

    International Nuclear Information System (INIS)

    Allen, Aaron M.; Schofield, Deborah; Hacker, Fred; Court, Laurence E.; Czerminska, Maria M.S.

    2007-01-01

    Purpose: To improve the target coverage and normal tissue sparing of intensity-modulated radiotherapy (IMRT) for mesothelioma after extrapleural pneumonectomy. Methods and Materials: Thirteen plans from patients previously treated with IMRT for mesothelioma were replanned using a restricted field technique. This technique was novel in two ways. It limited the entrance beams to 200 o around the target and three to four beams per case had their field apertures restricted down to the level of the heart or liver to further limit the contralateral lung dose. New constraints were added that included a mean lung dose of <9.5 Gy and volume receiving ≥5 Gy of <55%. Results: In all cases, the planning target volume coverage was excellent, with an average of 97% coverage of the planning target volume by the target dose. No change was seen in the target coverage with the new technique. The heart, kidneys, and esophagus were all kept under tolerance in all cases. The average mean lung dose, volume receiving ≥20 Gy, and volume receiving ≥5 Gy with the new technique was 6.6 Gy, 3.0%, and 50.8%, respectively, compared with 13.8 Gy, 15%, and 90% with the previous technique (p < 0.0001 for all three comparisons). The maximal value for any case in the cohort was 8.0 Gy, 7.3%, and 57.5% for the mean lung dose, volume receiving ≥20 Gy, and volume receiving ≥5 Gy, respectively. Conclusion: Restricted field IMRT provides an improved method to deliver IMRT to a complex target after extrapleural pneumonectomy. An upcoming Phase I trial will provide validation of these results

  17. Dosimetric impact of interplay effect in lung IMRT and VMAT treatment using in-house dynamic thorax phantom

    International Nuclear Information System (INIS)

    Mukhlisin; Pawiro, S A

    2016-01-01

    Tumor motion due to patient's respiratory is a significant problem in radiotherapy treatment of lung cancer. The purpose of this project is to study the interplay effect through dosimetry verification between the calculated and delivered dose, as well as the dosimetric impact of leaf interplay with breathing-induced tumor motion in IMRT and VMAT treatment. In this study, a dynamic thorax phantom was designed and constructed for dosimetry measurement. The phantom had a linear sinusoidal tumor motion toward superior-inferior direction with variation of amplitudes and periods. TLD-100 LiF:Mg,Ti and Gafchromic EBT2 film were used to measure dose in the midpoint target and the spinal cord. The IMRT and VMAT treatment had prescription dose of 200 cGy per fraction. The dosimetric impact due to interplay effect during IMRT and VMAT treatment were resulted in the range of 0.5% to -6.6% and 0.9% to -5.3% of target dose reduction, respectively. Meanwhile, mean dose deviation of spinal cord in IMRT and VMAT treatment were around 1.0% to -6.9% and 0.9% to -6.3%, respectively. The results showed that if respiratory management technique were not implemented, the presence of lung tumor motion during dose delivery in IMRT and VMAT treatment causes dose discrepancies inside tumor volume. (paper)

  18. Stereotactic Body Radiotherapy for Oligometastatic Lung Tumors

    International Nuclear Information System (INIS)

    Norihisa, Yoshiki; Nagata, Yasushi; Takayama, Kenji; Matsuo, Yukinori; Sakamoto, Takashi; Sakamoto, Masato; Mizowaki, Takashi; Yano, Shinsuke; Hiraoka, Masahiro

    2008-01-01

    Purpose: Since 1998, we have treated primary and oligometastatic lung tumors with stereotactic body radiotherapy (SBRT). The term 'oligometastasis' is used to indicate a small number of metastases limited to an organ. We evaluated our clinical experience of SBRT for oligometastatic lung tumors. Methods and Materials: A total of 34 patients with oligometastatic lung tumors were included in this study. The primary involved organs were the lung (n = 15), colorectum (n = 9), head and neck (n = 5), kidney (n = 3), breast (n = 1), and bone (n = 1). Five to seven, noncoplanar, static 6-MV photon beams were used to deliver 48 Gy (n = 18) or 60 Gy (n = 16) at the isocenter, with 12 Gy/fraction within 4-18 days (median, 12 days). Results: The overall survival rate, local relapse-free rate, and progression-free rate at 2 years was 84.3%, 90.0%, and 34.8%, respectively. No local progression was observed in tumors irradiated with 60 Gy. SBRT-related pulmonary toxicities were observed in 4 (12%) Grade 2 cases and 1 (3%) Grade 3 case. Patients with a longer disease-free interval had a greater overall survival rate. Conclusion: The clinical result of SBRT for oligometastatic lung tumors in our institute was comparable to that after surgical metastasectomy; thus, SBRT could be an effective treatment of pulmonary oligometastases

  19. SU-F-T-416: Dosimetric Comparison of Coplanar and Non-Coplanar IMRT Plans for Peripheral Lung Lesion

    International Nuclear Information System (INIS)

    Kang, J; Zhang, S; Philbrook, S; Paul, S; Wang, B

    2016-01-01

    Purpose: The purpose of this study was to compare dosimetric parameters of treatment plans between coplanar and non-coplanar techniques for treating peripheral lung lesions. Methods: The planning CT scans of 6 patients in supine positions were used in this study. The size of the PTV ranges from 163 c.c. to 782 c.c.. The locations of PTV are mostly at the peripheral of Lung, some spreading to the mediastinum. For each patient, we generated two IMRT plans, one with and the other without non-coplanar beams. The non-coplanar beams were carefully selected so that the beams would never exit patient bodies through the contralateral lung. The IMRT plans were generated with Pinnacle 9.8 treatment planning software. The IMRT optimization objectives were kept the same for the corresponding pairs of plans. All plans were normalized such that 95% of PTV receives the prescription dose (full dose). Results: The conformity index (mean±standard deviation of the mean) is 1.49±0.14 and 1.58±0.23 for the coplanar and noncoplanar plans, respectively. The heterogeneity index (mean±standard deviation of the mean) is 7.74 ±2.33 and 6.34±1.40 for the coplanar and non-coplanar plans, respectively. The maximum heart dose is 60.94±6.22 and 60.42±7.21 Gy, and mean heart dose is 10.22 ±7.57, 9.07 ±6.32 Gy, for the coplanar and non-coplanar plans, respectively. The ipsilateral lung V20 is 48.0%±2.4% and 47.5%±3.3%, and V5 is 68.2%±10.0% and 69.1%±7.3%, for the coplanar and noncoplanar plans, respectively. Furthermore, with the non-coplanar beam arrangement, the contralateral lung V20 was reduced from 3.3%±3.7% to 1.3%±0.8%, and the contralateral Lung V5 is reduced significantly from 65.6%±9.3% to 33.5%±20.9% (p value =0.008). Conclusion: The IMRT plans with non-coplanar beam arrangement could reduce the exit dose to the contralateral lung, and therefore reduce the contralateral lung V5 significantly. This method is especially helpful while the lung lesion doesn’t have a

  20. Stereotactic Body Radiotherapy for Centrally Located Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yuming WAN

    2018-05-01

    Full Text Available A few study has proven that about 90% of local control rates might be benefit from stereotactic body radiotherapy (SBRT for patients with medically inoperable stage I non-small cell lung cancer (NSCLC, it is reported SBRT associated overall survival and tumor specific survival is comparable with those treated with surgery. SBRT has been accepted as the first line treatment for inoperable patients with peripheral located stage I NSCLC. However, the role of SBRT in centrally located lesions is controversial for potential toxic effects from the adjacent anatomical structure. This paper will review the definition, indication, dose regimens, dose-volume constraints for organs at risk, radiation technology, treatment side effect of centrally located NSCLC treated with SBRT and stereotactic body proton therapy.

  1. CBCT-Guided Rapid Arc for stereotactic ablative radiotherapy (SABR) in lung tumors

    Energy Technology Data Exchange (ETDEWEB)

    Fandino, J. M.; Silva, M. C.; Izquierdo, P.; Candal, A.; Diaz, I.; Fernandez, C.; Gesto, C.; Poncet, M.; Soto, M.; Triana, G.; Losada, C.; Marino, A.

    2013-07-01

    Stereotactic ablative radiotherapy has emerged as a standard treatment option for stage I non-small cell lung cancer in patients unfit for surgery, or who refuse surgery. An increasing number of prospective phase I/II trials, as well as large single and multicenter studies have reported local control rates to be in excess of 85% for early stage non-small cell lung cancer. Volumetric arc therapy RapidArc with tumor-based image guidance technique will be presented as well as our preliminary observations. (Author)

  2. SU-F-T-352: Development of a Knowledge Based Automatic Lung IMRT Planning Algorithm with Non-Coplanar Beams

    International Nuclear Information System (INIS)

    Zhu, W; Wu, Q; Yuan, L

    2016-01-01

    Purpose: To improve the robustness of a knowledge based automatic lung IMRT planning method and to further validate the reliability of this algorithm by utilizing for the planning of clinical cases with non-coplanar beams. Methods: A lung IMRT planning method which automatically determines both plan optimization objectives and beam configurations with non-coplanar beams has been reported previously. A beam efficiency index map is constructed to guide beam angle selection in this algorithm. This index takes into account both the dose contributions from individual beams and the combined effect of multiple beams which is represented by a beam separation score. We studied the effect of this beam separation score on plan quality and determined the optimal weight for this score.14 clinical plans were re-planned with the knowledge-based algorithm. Significant dosimetric metrics for the PTV and OARs in the automatic plans are compared with those in the clinical plans by the two-sample t-test. In addition, a composite dosimetric quality index was defined to obtain the relationship between the plan quality and the beam separation score. Results: On average, we observed more than 15% reduction on conformity index and homogeneity index for PTV and V_4_0, V_6_0 for heart while an 8% and 3% increase on V_5, V_2_0 for lungs, respectively. The variation curve of the composite index as a function of angle spread score shows that 0.6 is the best value for the weight of the beam separation score. Conclusion: Optimal value for beam angle spread score in automatic lung IMRT planning is obtained. With this value, model can result in statistically the “best” achievable plans. This method can potentially improve the quality and planning efficiency for IMRT plans with no-coplanar angles.

  3. Respiratory gating during stereotactic body radiotherapy for lung cancer reduces tumor position variability.

    Science.gov (United States)

    Saito, Tetsuo; Matsuyama, Tomohiko; Toya, Ryo; Fukugawa, Yoshiyuki; Toyofuku, Takamasa; Semba, Akiko; Oya, Natsuo

    2014-01-01

    We evaluated the effects of respiratory gating on treatment accuracy in lung cancer patients undergoing lung stereotactic body radiotherapy by using electronic portal imaging device (EPID) images. Our study population consisted of 30 lung cancer patients treated with stereotactic body radiotherapy (48 Gy/4 fractions/4 to 9 days). Of these, 14 were treated with- (group A) and 16 without gating (group B); typically the patients whose tumors showed three-dimensional respiratory motion ≧5 mm were selected for gating. Tumor respiratory motion was estimated using four-dimensional computed tomography images acquired during treatment simulation. Tumor position variability during all treatment sessions was assessed by measuring the standard deviation (SD) and range of tumor displacement on EPID images. The two groups were compared for tumor respiratory motion and position variability using the Mann-Whitney U test. The median three-dimensional tumor motion during simulation was greater in group A than group B (9 mm, range 3-30 mm vs. 2 mm, range 0-4 mm; psimulation, tumor position variability in the EPID images was low and comparable to patients treated without gating. This demonstrates the benefit of respiratory gating.

  4. Stereotactic radiation therapy: a second gold standard in the treatment of early-stage lung cancer?

    International Nuclear Information System (INIS)

    Santini B, Alejandro; Valdez C, Cristian; Sepulveda A, Veronica; Baeza L, Ricardo; Bustos, Sergio

    2016-01-01

    Lung cancer is still the leading cause of cancer death in the world. Although in Chile this is not the case, the northern regions of the country show higher incidence and mortality rates than the other Chilean regions. In recent years screening guides for lung cancer with low-dose scanner have begun to be established, and most of the medical societies involved in this subject have already settled the selection criteria. At the same time new techniques of treatment for these patients have developed, with highly sophisticated radiotherapy such as SBRT (Stereotactic Body Radiotherapy) and SBART (Stereotactic ablative body radiation therapy) that are revealing extremely encouraging results and augur significant changes in the coming years. In the present review we analyze the current work, their results, and the future of this treatment modality

  5. Critical structure sparing in stereotactic ablative radiotherapy for central lung lesions: helical tomotherapy vs. volumetric modulated arc therapy.

    Directory of Open Access Journals (Sweden)

    Alexander Chi

    Full Text Available BACKGROUND: Helical tomotherapy (HT and volumetric modulated arc therapy (VMAT are both advanced techniques of delivering intensity-modulated radiotherapy (IMRT. Here, we conduct a study to compare HT and partial-arc VMAT in their ability to spare organs at risk (OARs when stereotactic ablative radiotherapy (SABR is delivered to treat centrally located early stage non-small-cell lung cancer or lung metastases. METHODS: 12 patients with centrally located lung lesions were randomly chosen. HT, 2 & 8 arc (Smart Arc, Pinnacle v9.0 plans were generated to deliver 70 Gy in 10 fractions to the planning target volume (PTV. Target and OAR dose parameters were compared. Each technique's ability to meet dose constraints was further investigated. RESULTS: HT and VMAT plans generated essentially equivalent PTV coverage and dose conformality indices, while a trend for improved dose homogeneity by increasing from 2 to 8 arcs was observed with VMAT. Increasing the number of arcs with VMAT also led to some improvement in OAR sparing. After normalizing to OAR dose constraints, HT was found to be superior to 2 or 8-arc VMAT for optimal OAR sparing (meeting all the dose constraints (p = 0.0004. All dose constraints were met in HT plans. Increasing from 2 to 8 arcs could not help achieve optimal OAR sparing for 4 patients. 2/4 of them had 3 immediately adjacent structures. CONCLUSION: HT appears to be superior to VMAT in OAR sparing mainly in cases which require conformal dose avoidance of multiple immediately adjacent OARs. For such cases, increasing the number of arcs in VMAT cannot significantly improve OAR sparing.

  6. An open source solution for an in-house built dynamic platform for the validation of stereotactic ablative body radiotherapy for VMAT and IMRT.

    Science.gov (United States)

    Munoz, Luis; Ziebell, Amy; Morton, Jason; Bhat, Madhava

    2016-12-01

    An in-house solution for the verification of dose delivered to a moving phantom as required for the clinical implementation of lung stereotactic ablative body radiation therapy was developed. The superior-inferior movement required to simulate tumour motion during a normal breathing cycle was achieved via the novel use of an Arduino Uno™, a low-cost open-source microcontroller board connected to a high torque servo motor. Slow CT imaging was used to acquire the image set and a 4D cone beam CT (4D-CBCT) verified the efficacy of contoured margins before treatment on the moving phantom. Treatment fields were delivered to a section of a CIRS™ anthropomorphic phantom. Dose verification to the dynamic phantom with Gafchromic EBT3 film using 3 %-1 mm gamma analysis acceptance criteria registered an absolute dose pass rate for IMRT and VMAT of 98 and 96.6 %, respectively. It was verified that 100 % of the PTV received the prescribed dose of 12 Gy per fraction using the dynamic phantom, and no major discrepancy between planned and measured results due to interplay between multileaf collimator sequences and target motion was observed. This study confirmed that the use of an in-house solution using open source hardware and software with existing quality assurance equipment was appropriate in validating a new treatment technique.

  7. Patient-reported quality of life after stereotactic ablative radiotherapy for early-stage lung cancer

    NARCIS (Netherlands)

    Lagerwaard, F.J.; Aaronson, N.K.; Gundy, C.M.; Haasbeek, C.J.A.; Slotman, B.J.; Senan, S.

    2012-01-01

    Background: Deterioration in health-related quality of life (HRQOL) is frequently observed after surgery for stage I non-small-cell lung cancer. As stereotactic ablative radiotherapy (SABR) can result in local control percentages exceeding 90%, we studied baseline and post-treatment HRQOL in SABR

  8. Optimization of Stereotactic Radiotherapy Treatment Delivery Technique for Base-Of-Skull Meningiomas

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Candish, Charles; Vollans, Emily; Gete, Ermias; Lee, Richard; Martin, Monty; Ma, Roy; McKenzie, Michael

    2008-01-01

    This study compares static conformal field (CF), intensity modulated radiotherapy (IMRT), and dynamic arcs (DA) for the stereotactic radiotherapy of base-of-skull meningiomas. Twenty-one cases of base-of-skull meningioma (median planning target volume [PTV] = 21.3 cm 3 ) previously treated with stereotactic radiotherapy were replanned with each technique. The plans were compared for Radiation Therapy Oncology Group conformity index (CI) and homogeneity index (HI), and doses to normal structures at 6 dose values from 50.4 Gy to 5.6 Gy. The mean CI was 1.75 (CF), 1.75 (DA), and 1.66 (IMRT) (p 3 , the CI (IMRT) was always superior to CI (DA) and CI (CF). At PTV sizes below 25 cm 3 , there was no significant difference in CI between each technique. There was no significant difference in HI between plans. The total volume of normal tissue receiving 50.4, 44.8, and 5.6 Gy was significantly lower when comparing IMRT to CF and DA plans (p 3 , due to improved conformity and normal tissue sparing, in particular for the brain stem and ipsilateral temporal lobe

  9. Quality of Life After Stereotactic Radiotherapy for Stage I Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Voort van Zyp, Noelle C. van der; Prevost, Jean-Briac; Holt, Bronno van der; Braat, Cora; Klaveren, Robertus J. van; Pattynama, Peter M.; Levendag, Peter C.; Nuyttens, Joost J.

    2010-01-01

    Purpose: To determine the impact of stereotactic radiotherapy on the quality of life of patients with inoperable early-stage non-small-cell lung cancer (NSCLC). Overall survival, local tumor control, and toxicity were also evaluated in this prospective study. Methods and Materials: From January 2006 to February 2008, quality of life, overall survival, and local tumor control were assessed in 39 patients with pathologically confirmed T1 to 2N0M0 NSCLC. These patients were treated with stereotactic radiotherapy. The European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ) C30 and the QLQ LC13 lung cancer-specific questionnaire were used to investigate changes in quality of life. Assessments were done before treatment, at 3 weeks, and at 2, 4, 6, 9, and 12 months after treatment, until death or progressive disease. Toxicity was evaluated using common terminology criteria for adverse events version 3.0. Results: Emotional functioning improved significantly after treatment. Other function scores and QLQ C30 and QLQ LC13 lung symptoms (such as dyspnea and coughing) showed no significant changes. The overall 2-year survival rate was 62%. After a median follow-up of 17 months, 1 patient had a local recurrence (3%). No grade 4 or 5 treatment-related toxicity occurred. Grade 3 toxicity consisted of thoracic pain, which occurred in 1 patient within 4 months of treatment, while it occurred thereafter in 2 patients. Conclusions: Quality of life was maintained, and emotional functioning improved significantly after stereotactic radiotherapy for stage I NSCLC, while survival was acceptable, local tumor control was high, and toxicity was low.

  10. Lung Volume Reduction After Stereotactic Ablative Radiation Therapy of Lung Tumors: Potential Application to Emphysema

    Energy Technology Data Exchange (ETDEWEB)

    Binkley, Michael S. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Shrager, Joseph B. [Division of Thoracic Surgery, Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Leung, Ann N. [Department of Radiology, Stanford University School of Medicine, Stanford, California (United States); Popat, Rita [Department of Health Research and Policy, Stanford University School of Medicine, Stanford, California (United States); Trakul, Nicholas [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Department of Radiation Oncology, University of Southern California Keck School of Medicine, Los Angeles, California (United States); Atwood, Todd F.; Chaudhuri, Aadel [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Diehn, Maximilian, E-mail: Diehn@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Institute for Stem Cell Biology and Regenerative Medicine, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2014-09-01

    Purpose: Lung volume reduction surgery (LVRS) improves dyspnea and other outcomes in selected patients with severe emphysema, but many have excessive surgical risk for LVRS. We analyzed the dose-volume relationship for lobar volume reduction after stereotactic ablative radiation therapy (SABR) of lung tumors, hypothesizing that SABR could achieve therapeutic volume reduction if applied in emphysema. Methods and Materials: We retrospectively identified patients treated from 2007 to 2011 who had SABR for 1 lung tumor, pre-SABR pulmonary function testing, and ≥6 months computed tomographic (CT) imaging follow-up. We contoured the treated lobe and untreated adjacent lobe(s) on CT before and after SABR and calculated their volume changes relative to the contoured total (bilateral) lung volume (TLV). We correlated lobar volume reduction with the volume receiving high biologically effective doses (BED, α/β = 3). Results: 27 patients met the inclusion criteria, with a median CT follow-up time of 14 months. There was no grade ≥3 toxicity. The median volume reduction of the treated lobe was 4.4% of TLV (range, −0.4%-10.8%); the median expansion of the untreated adjacent lobe was 2.6% of TLV (range, −3.9%-11.6%). The volume reduction of the treated lobe was positively correlated with the volume receiving BED ≥60 Gy (r{sup 2}=0.45, P=.0001). This persisted in subgroups determined by high versus low pre-SABR forced expiratory volume in 1 second, treated lobe CT emphysema score, number of fractions, follow-up CT time, central versus peripheral location, and upper versus lower lobe location, with no significant differences in effect size between subgroups. Volume expansion of the untreated adjacent lobe(s) was positively correlated with volume reduction of the treated lobe (r{sup 2}=0.47, P<.0001). Conclusions: We identified a dose-volume response for treated lobe volume reduction and adjacent lobe compensatory expansion after lung tumor SABR, consistent across

  11. Dosimetric impact of a frame-based strategy in stereotactic radiotherapy of lung tumors

    International Nuclear Information System (INIS)

    Waldeland, Einar; Ramberg, Christina; Arnesen, Marius Roethe; Helland, Aaslaug; Brustugun, Odd Terje; Malinen, Eirik

    2012-01-01

    Introduction. Technological innovations have taken stereotactic body radiotherapy (SBRT) from frame-based strategies to image-guided strategies. In this study, cone beam computed tomography (CBCT) images acquired prior to SBRT of patients with lung tumors was used to study the dosimetric impact of a pure frame-based strategy. Material and methods. Thirty patients with inoperable lung tumors were retrospectively analyzed. All patients had received CBCT-guided SBRT with 3 fractions of 15 Gy to the planning target volume (PTV) margin including immobilization in a stereotactic body frame (SBF). Using the set-up corrections from the co-registration of the CBCT with the planning CT, all individual dose plans were recalculated with an isocenter position equal to the initial set-up position. Dose Volume Histogram (DVH) parameters of the recalculated dose plans were then analyzed. Results. The simulated plans showed that 88% of all fractions resulted in minimum 14.5 Gy to the internal target volume (ITV). For the simulated summed treatment (3 fractions per patient), 83% of the patients would minimum receive the prescription dose (45 Gy) to 100% of the ITV and all except one would receive the prescription dose to more than 90% of the ITV. Conclusions. SBRT including SBF, but without image guidance, results in appropriate dose coverage in most cases, using the current margins. With image guidance, margins for SBRT of lung tumors could possibly be reduced

  12. Treatment of Sarcoma Lung Metastases with Stereotactic Body Radiotherapy

    Directory of Open Access Journals (Sweden)

    Adam D. Lindsay

    2018-01-01

    Full Text Available Background. The most common site of sarcoma metastasis is the lung. Surgical resection of pulmonary metastases and chemotherapy are treatment options that have been employed, but many patients are poor candidates for these treatments for multiple host or tumor-related reasons. In this group of patients, radiation might provide a less morbid treatment alternative. We sought to evaluate the efficacy of radiotherapy in the treatment of metastatic sarcoma to the lung. Methods. Stereotactic body radiotherapy (SBRT was used to treat 117 pulmonary metastases in 44 patients. Patients were followed with serial computed tomography imaging of the chest. The primary endpoint was failure of control of a pulmonary lesion as measured by continued growth. Radiation-associated complications were recorded. Results. The majority of patients (84% received a total dose of 50 Gy per metastatic nodule utilizing an image-guided SBRT technique. The median interval follow-up was 14.2 months (range 1.6–98.6 months. Overall survival was 82% at two years and 50% at five years. Of 117 metastatic nodules treated, six nodules showed failure of treatment (95% control rate. Twenty patients (27% developed new metastatic lesions and underwent further SBRT. The side effects of SBRT included transient radiation pneumonitis n=6, cough n=2, rib fracture n=1, chronic pain n=1, dermatitis n=1, and dyspnea n=1. Conclusion. Stereotactic body radiotherapy is an effective and safe treatment for the ablation of pulmonary metastasis from sarcoma. Further work is needed to evaluate the optimal role of SBRT relative to surgery or chemotherapy for treatment of metastatic sarcoma.

  13. Lung deformations and radiation-induced regional lung collapse in patients treated with stereotactic body radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Diot, Quentin, E-mail: quentin.diot@ucdenver.edu; Kavanagh, Brian; Vinogradskiy, Yevgeniy; Gaspar, Laurie; Miften, Moyed [Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado 80045 (United States); Garg, Kavita [Department of Radiology, University of Colorado School of Medicine, Aurora, Colorado 80045 (United States)

    2015-11-15

    Purpose: To differentiate radiation-induced fibrosis from regional lung collapse outside of the high dose region in patients treated with stereotactic body radiation therapy (SBRT) for lung tumors. Methods: Lung deformation maps were computed from pre-treatment and post-treatment computed tomography (CT) scans using a point-to-point translation method. Fifty anatomical landmarks inside the lung (vessel or airway branches) were matched on planning and follow-up scans for the computation process. Two methods using the deformation maps were developed to differentiate regional lung collapse from fibrosis: vector field and Jacobian methods. A total of 40 planning and follow-ups CT scans were analyzed for 20 lung SBRT patients. Results: Regional lung collapse was detected in 15 patients (75%) using the vector field method, in ten patients (50%) using the Jacobian method, and in 12 patients (60%) by radiologists. In terms of sensitivity and specificity the Jacobian method performed better. Only weak correlations were observed between the dose to the proximal airways and the occurrence of regional lung collapse. Conclusions: The authors presented and evaluated two novel methods using anatomical lung deformations to investigate lung collapse and fibrosis caused by SBRT treatment. Differentiation of these distinct physiological mechanisms beyond what is usually labeled “fibrosis” is necessary for accurate modeling of lung SBRT-induced injuries. With the help of better models, it becomes possible to expand the therapeutic benefits of SBRT to a larger population of lung patients with large or centrally located tumors that were previously considered ineligible.

  14. Current Status of Stereotactic Ablative Radiotherapy (SABR for Early-stage 
Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Anhui SHI

    2016-06-01

    Full Text Available High level evidence from randomized studies comparing stereotactic ablative radiotherapy (SABR to surgery is lacking. Although the results of pooled analysis of two randomized trials for STARS and ROSEL showed that SABR is better tolerated and might lead to better overall survival than surgery for operable clinical stage I non-small cell lung cancer (NSCLC, SABR, however, is only recommended as a preferred treatment option for early stage NSCLC patients who cannot or will not undergo surgery. We, therefore, are waiting for the results of the ongoing randomized studies [Veterans affairs lung cancer surgery or stereotactic radiotherapy in the US (VALOR and the SABRTooth study in the United Kingdom (SABRTooths]. Many retrospective and case control studies showed that SABR is safe and effective (local control rate higher than 90%, 5 years survival rate reached 70%, but there are considerable variations in the definitions and staging of lung cancer, operability determination, and surgical approaches to operable lung cancer (open vs video-assisted. Therefore, it is difficult to compare the superiority of radiotherapy and surgery in the treatment of early staged lung cancer. Most studies demonstrated that the efficacy of the two modalities for early staged lung cancer is equivalent; however, due to the limited data, the conclusions from those studies are difficult to be evidence based. Therefore, the controversies will be focusing on the safety and invasiveness of the two treatment modalities. This article will review the ongoing debate in light of these goals.

  15. Factors affecting the local control of stereotactic body radiotherapy for lung tumors including primary lung cancer and metastatic lung tumors

    International Nuclear Information System (INIS)

    Hamamoto, Yasushi; Kataoka, Masaaki; Yamashita, Motohiro

    2012-01-01

    The purpose of this study was to identify factors affecting local control of stereotactic body radiotherapy (SBRT) for lung tumors including primary lung cancer and metastatic lung tumors. Between June 2006 and June 2009, 159 lung tumors in 144 patients (primary lung cancer, 128; metastatic lung tumor, 31) were treated with SBRT with 48-60 Gy (mean 50.1 Gy) in 4-5 fractions. Higher doses were given to larger tumors and metastatic tumors in principle. Assessed factors were age, gender, tumor origin (primary vs. metastatic), histological subtype, tumor size, tumor appearance (solid vs. ground glass opacity), maximum standardized uptake value of positron emission tomography using 18 F-fluoro-2-deoxy-D-glucose, and SBRT doses. Follow-up time was 1-60 months (median 18 months). The 1-, 2-, and 3-year local failure-free rates of all lesions were 90, 80, and 77%, respectively. On univariate analysis, metastatic tumors (p<0.0001), solid tumors (p=0.0246), and higher SBRT doses (p=0.0334) were the statistically significant unfavorable factors for local control. On multivariate analysis, only tumor origin was statistically significant (p=0.0027). The 2-year local failure-free rates of primary lung cancer and metastatic lung tumors were 87 and 50%, respectively. A metastatic tumor was the only independently significant unfavorable factor for local control after SBRT. (author)

  16. Feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in lung cancer treatment planning

    International Nuclear Information System (INIS)

    Xiao Jianghong; Zhang Hong; Gong Youling; Fu Yuchuan; Tang Bin; Wang Shichao; Jiang Qingfeng; Li Ping

    2010-01-01

    Background and purpose: To investigate the feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in 3-dimensional conformal radiotherapy (3D-CRT), stereotactic body radiation therapy (SBRT) and intensity-modulated radiotherapy (IMRT) treatment planning for lung cancers, respectively. Materials and methods: Twelve patients with bulky lung tumors and 14 patients with small lung tumors were retrospectively analyzed. Each patient took two sets of CT in the same position with active breathing control (ABC) technique before and after intravenous contrast agent (CA) injections. Bulky tumors were planned with 3D-CRT, while SBRT plans were generated for patients with small tumors based on CT scans with intravenous CA. In addition, IMRT plans were generated for patients with bulky tumors to continue on a planning study. All plans were copied and replaced on the scans without intravenous CA. The radiation doses calculated from the two sets of CTs were compared with regard to planning volumes (PTV), the organ at-risk (OAR) and the lungs using Wilcoxon's signed rank test. Results: In comparisons for 3D-CRT plans, CT scans with intravenous CA reduced the mean dose and the maximum dose of PTV with significant differences (p 95 ) for targets, respectively (p < 0.05). There was no statistical significance for lung parameters between two sets of scans in SBRT plans and IMRT plans. Conclusions: The enhanced CT scans can be used for both target delineation and treatment planning in 3D-CRT. The dose difference caused by intravenous CA is small. But for SBRT and IMRT, the minimum irradiation dose in targets may be estimated to be increased up to 2.71% while the maximum dose may be estimated to be decreased up to 1.36%. However, the difference in dose distribution in most cases were found to be clinical tolerable.

  17. Image-Guided Radiotherapy via Daily Online Cone-Beam CT Substantially Reduces Margin Requirements for Stereotactic Lung Radiotherapy

    International Nuclear Information System (INIS)

    Grills, Inga S.; Hugo, Geoffrey; Kestin, Larry L.; Galerani, Ana Paula; Chao, K. Kenneth; Wloch, Jennifer; Yan Di

    2008-01-01

    Purpose: To determine treatment accuracy and margins for stereotactic lung radiotherapy with and without cone-beam CT (CBCT) image guidance. Methods and Materials: Acquired for the study were 308 CBCT of 24 patients with solitary peripheral lung tumors treated with stereotactic radiotherapy. Patients were immobilized in a stereotactic body frame (SBF) or alpha-cradle and treated with image guidance using daily CBCT. Four (T1) or five (T2/metastatic) 12-Gy fractions were prescribed to the planning target volume (PTV) edge. The PTV margin was ≥5 mm depending on a pretreatment estimate of tumor excursion. Initial daily setup was according to SBF coordinates or tattoos for alpha-cradle cases. A CBCT was performed and registered to the planning CT using soft tissue registration of the target. The initial setup error/precorrection position, was recorded for the superior-inferior, anterior-posterior, and medial-lateral directions. The couch was adjusted to correct the tumor positional error. A second CBCT verified tumor position after correction. Patients were treated in the corrected position after the residual errors were ≤2 mm. A final CBCT after treatment assessed intrafraction tumor displacement. Results: The precorrection systematic (Σ) and random errors (σ) for the population ranged from 2-3 mm for SBF and 2-6 mm for alpha-cradle patients; postcorrection errors ranged from 0.4-1.0 mm. Calculated population margins were 9 to 13 mm (SBF) and 10-14 mm (cradle) precorrection, 1-2 mm (SBF), and 2-3 mm (cradle) postcorrection, and 2-4 mm (SBF) and 2-5 mm (cradle) posttreatment. Conclusions: Setup for stereotactic lung radiotherapy using a SBF or alpha-cradle alone is suboptimal. CBCT image guidance significantly improves target positioning and substantially reduces required target margins and normal tissue irradiation

  18. Stereotactic Ablative Body Radiation Therapy for Octogenarians With Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Atsuya; Sanuki, Naoko; Eriguchi, Takahisa [Radiation Oncology Center, Ofuna Chuo Hospital, Kanagawa (Japan); Kaneko, Takeshi [Respiratory Disease Center, Yokohama City University Medical Center, Kanagawa (Japan); Department of Respirology, Ofuna Chuo Hospital, Kanagawa (Japan); Morita, Satoshi [Department of Biostatistics and Epidemiology, Graduate School of Medicine, Yokohama City University, Kanagawa (Japan); Handa, Hiroshi [Respiratory Disease Center, Yokohama City University Medical Center, Kanagawa (Japan); Division of Respiratory and Infectious Diseases, Department of Internal Medicine, St. Marianna University School of Medicine, Kanagawa (Japan); Aoki, Yousuke; Oku, Yohei [Radiation Oncology Center, Ofuna Chuo Hospital, Kanagawa (Japan); Kunieda, Etsuo, E-mail: kunieda-mi@umin.ac.jp [Department of Radiation Oncology, Tokai University, Kanagawa (Japan)

    2013-06-01

    Purpose: To retrospectively investigate treatment outcomes of stereotactic ablative body radiation therapy (SABR) for octogenarians with non-small cell lung cancer (NSCLC). Methods and Materials: Between 2005 and 2012, 109 patients aged ≥80 years with T1-2N0M0 NSCLC were treated with SABR: 47 patients had histology-unproven lung cancer; 62 patients had pathologically proven NSCLC. The prescribed doses were either 50 Gy/5 fractions for peripheral tumors or 40 Gy/5 fractions for centrally located tumors. The treatment outcomes, toxicities, and the correlating factors for overall survival (OS) were evaluated. Results: The median follow-up duration after SABR was 24.2 (range, 3.0-64.6) months. Only limited toxicities were observed, except for 1 grade 5 radiation pneumonitis. The 3-year local, regional, and distant metastasis-free survival rates were 82.3%, 90.1%, and 76.8%, respectively. The OS and lung cancer-specific survival rates were 53.7% and 70.8%, respectively. Multivariate analysis revealed that medically inoperable, low body mass index, high T stage, and high C-reactive protein were the predictors for short OS. The OS for the operable octogenarians was significantly better than that for inoperable (P<.01). Conclusions: Stereotactic ablative body radiation therapy for octogenarians was feasible, with excellent OS. Multivariate analysis revealed that operability was one of the predictors for OS. For medically operable octogenarians with early-stage NSCLC, SABR should be prospectively compared with resection.

  19. Development and evaluation of a clinical model for lung cancer patients using stereotactic body radiotherapy (SBRT) within a knowledge-based algorithm for treatment planning.

    Science.gov (United States)

    Chin Snyder, Karen; Kim, Jinkoo; Reding, Anne; Fraser, Corey; Gordon, James; Ajlouni, Munther; Movsas, Benjamin; Chetty, Indrin J

    2016-11-08

    The purpose of this study was to describe the development of a clinical model for lung cancer patients treated with stereotactic body radiotherapy (SBRT) within a knowledge-based algorithm for treatment planning, and to evaluate the model performance and applicability to different planning techniques, tumor locations, and beam arrangements. 105 SBRT plans for lung cancer patients previously treated at our institution were included in the development of the knowledge-based model (KBM). The KBM was trained with a combination of IMRT, VMAT, and 3D CRT techniques. Model performance was validated with 25 cases, for both IMRT and VMAT. The full KBM encompassed lesions located centrally vs. peripherally (43:62), upper vs. lower (62:43), and anterior vs. posterior (60:45). Four separate sub-KBMs were created based on tumor location. Results were compared with the full KBM to evaluate its robustness. Beam templates were used in conjunction with the optimizer to evaluate the model's ability to handle suboptimal beam placements. Dose differences to organs-at-risk (OAR) were evaluated between the plans gener-ated by each KBM. Knowledge-based plans (KBPs) were comparable to clinical plans with respect to target conformity and OAR doses. The KBPs resulted in a lower maximum spinal cord dose by 1.0 ± 1.6 Gy compared to clinical plans, p = 0.007. Sub-KBMs split according to tumor location did not produce significantly better DVH estimates compared to the full KBM. For central lesions, compared to the full KBM, the peripheral sub-KBM resulted in lower dose to 0.035 cc and 5 cc of the esophagus, both by 0.4Gy ± 0.8Gy, p = 0.025. For all lesions, compared to the full KBM, the posterior sub-KBM resulted in higher dose to 0.035 cc, 0.35 cc, and 1.2 cc of the spinal cord by 0.2 ± 0.4Gy, p = 0.01. Plans using template beam arrangements met target and OAR criteria, with an increase noted in maximum heart dose (1.2 ± 2.2Gy, p = 0.01) and GI (0.2 ± 0.4, p = 0.01) for the nine

  20. Patient reported outcomes following stereotactic ablative radiotherapy or surgery for stage IA non-small-cell lung cancer : Results from the ROSEL multicenter randomized trial

    NARCIS (Netherlands)

    Louie, Alexander V.; van Werkhoven, Erik; Chen, Hanbo; Smit, Egbert F.; Paul, Marinus A.; Widder, Joachim; Groen, Harry J. M.; van den Borne, Ben E. E. M.; De Jaeger, Katrien; Slotman, Ben J.; Senan, Suresh

    2015-01-01

    We report quality of life and indirect costs from patient reported outcomes from the ROSEL randomized control trial comparing stereotactic ablative radiotherapy (SABR, also known as stereotactic body radiotherapy or SBRT) versus surgical resection for medically operable stage IA non-small cell lung

  1. Salvage surgery for local failures after stereotactic ablative radiotherapy for early stage non-small cell lung cancer

    NARCIS (Netherlands)

    N. Verstegen (Naomi); A.W.P.M. Maat (Alex); F.J. Lagerwaard (Frank); M.A. Paul (Marinus); M. Versteegh (Michel); J.J. Joosten (Joris); W. Lastdrager (Willem); E.F. Smit (Egbert); B.J. Slotman (Ben); J.J.M.E. Nuyttens (Joost); S. Senan (Suresh)

    2016-01-01

    markdownabstract__Introduction:__ The literature on surgical salvage, i.e. lung resections in patients who develop a local recurrence following stereotactic ablative radiotherapy (SABR), is limited. We describe our experience with salvage surgery in nine patients who developed a local recurrence

  2. Dosimetric evaluation of a moving tumor target in intensity-modulated radiation therapy (IMRT) for lung cancer patients

    Science.gov (United States)

    Kim, Sung Kyu; Kang, Min Kyu; Yea, Ji Woon; Oh, Se An

    2013-07-01

    Immobilization plays an important role in intensity-modulated radiation therapy (IMRT). The application of IMRT in lung cancer patients is very difficult due to the movement of the tumor target. Patient setup in radiation treatment demands high accuracy because IMRT employs a treatment size of a 1mm pixel unit. Hence, quality assurance of the dose delivered to patients must be at its highest. The radiation dose was evaluated for breathing rates of 9, 14, and 18 breaths per minute (bpm) for tumor targets moving up and down by 1.0 cm and 1.5 cm. The dose of the moving planned target volume (PTV) was measured by using a thermo-luminescent dosimeter (TLD) and Gafchromic™ EBT film. The measurement points were 1.0 cm away from the top, the bottom and the left and the right sides of the PTV center. The evaluated dose differences ranged from 94.2 to 103.8%, from 94.4 to 105.4%, and from 90.7 to 108.5% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.0 cm. The mean values of the doses were 101.4, 99.9, and 99.5% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.0 cm. Meanwhile, the evaluated dose differences ranged from 93.6 to 105.8%, from 95.9 to 111.5%, and from 96.2 to 111.7% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.5 cm. The mean values of the doses were 102.3, 103.4, and 103.1% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.5 cm. Therefore, we suggest that IMRT can be used in the treatment of lung cancer patients with vertical target movements within the range of 1.0 to 1.5 cm.

  3. SU-E-P-47: Evaluation of Improvement of Esophagus Sparing in SBRT Lung Patients with Biologically Based IMRT Optimization

    International Nuclear Information System (INIS)

    Liang, X; Penagaricano, J; Paudel, N; Zhang, X; Morrill, S; Corry, P; Han, E; Hardee, M; Ratanatharathorn, V

    2015-01-01

    Purpose: To study the potential of improving esophageal sparing for stereotactic body radiation therapy (SBRT) lung cancer patients by using biological optimization (BO) compared to conventional dose-volume based optimization (DVO) in treatment planning. Methods: Three NSCLC patients (PTV (62.3cc, 65.1cc, and 125.1cc) adjacent to the heart) previously treated with SBRT were re-planned using Varian Eclipse TPS (V11) using DVO and BO. The prescription dose was 60 Gy in 5 fractions normalized to 95% of the PTV volume. Plans were evaluated by comparing esophageal maximum doses, PTV heterogeneity (HI= D5%/D95%), and Paddick’s conformity (CI) indices. Quality of the plans was assessed by clinically-used IMRT QA procedures. Results: By using BO, the maximum dose to the esophagus was decreased 1384 cGy (34.6%), 502 cGy (16.5%) and 532 cGy (16.2%) in patient 1, 2 and 3 respectively. The maximum doses to spinal cord and the doses to 1000 cc and 1500 cc of normal lung were comparable in both plans. The mean doses (Dmean-hrt) and doses to 15cc of the heart (V15-hrt) were comparable for patient 1 and 2. However for patient 3, with the largest PTV, Dmean-hrt and V15-hrt increased by 62.2 cGy (18.3%) and 549.9 cGy (24.9%) respectively for the BO plans. The mean target HI of BO plans (1.13) was inferior to the DVO plans (1.07). The same trend was also observed for mean CI in BO plans (0.77) versus DVO plans (0.83). The QA pass rates (3%, 3mm) were comparable for both plans. Conclusion: This study demonstrated that the use of biological models in treatment planning optimization can substantially improve esophageal sparing without compromising spinal cord and normal lung doses. However, for the large PTV case (125.1cc) we studied here, Dmean-hrt and V15-hrt increased substantially. The target HI and CI were inferior in the BO plans

  4. Dose profile measurements during respiratory-gated lung stereotactic radiotherapy: A phantom study

    International Nuclear Information System (INIS)

    Jong, W L; Ung, N M; Wong, J H D; Ng, K H

    2016-01-01

    During stereotactic body radiotherapy, high radiation dose (∼60 Gy) is delivered to the tumour in small fractionation regime. In this study, the dosimetric characteristics were studied using radiochromic film during respiratory-gated and non-gated lung stereotactic body radiotherapy (SBRT). Specifically, the effect of respiratory cycle and amplitude, as well as gating window on the dosimetry were studied. In this study, the dose profiles along the irradiated area were measured. The dose profiles for respiratory-gated radiation delivery with different respiratory or tumour motion amplitudes, gating windows and respiratory time per cycle were in agreement with static radiation delivery. The respiratory gating system was able to deliver the radiation dose accurately (±1.05 mm) in the longitudinal direction. Although the treatment time for respiratory-gated SBRT was prolonged, this approach can potentially reduce the margin for internal tumour volume without compromising the tumour coverage. In addition, the normal tissue sparing effect can be improved. (paper)

  5. Hypofractionated Stereotactic Radiosurgery in a Large Bilateral Thalamic and Basal Ganglia Arteriovenous Malformation

    Directory of Open Access Journals (Sweden)

    Janet Lee

    2013-01-01

    Full Text Available Purpose. Arteriovenous malformations (AVMs in the basal ganglia and thalamus have a more aggressive natural history with a higher morbidity and mortality than AVMs in other locations. Optimal treatment—complete obliteration without new neurological deficits—is often challenging. We present a patient with a large bilateral basal ganglia and thalamic AVM successfully treated with hypofractionated stereotactic radiosurgery (HFSRS with intensity modulated radiotherapy (IMRT. Methods. The patient was treated with hypofractionated stereotactic radiosurgery to 30 Gy at margin in 5 fractions of 9 static fields with a minimultileaf collimator and intensity modulated radiotherapy. Results. At 10 months following treatment, digital subtraction angiography showed complete obliteration of the AVM. Conclusions. Large bilateral thalamic and basal ganglia AVMs can be successfully treated with complete obliteration by HFSRS with IMRT with relatively limited toxicity. Appropriate caution is recommended.

  6. Multifractionated image-guided and stereotactic intensity-modulated radiotherapy of paraspinal tumors: A preliminary report

    International Nuclear Information System (INIS)

    Yamada, Yoshiya; Lovelock, D. Michael; Yenice, Kamil M.; Bilsky, Mark H.; Hunt, Margaret A.; Zatcky, Joan; Leibel, Steven A.

    2005-01-01

    Purpose: The use of image-guided and stereotactic intensity-modulated radiotherapy (IMRT) techniques have made the delivery of high-dose radiation to lesions within close proximity to the spinal cord feasible. This report presents clinical and physical data regarding the use of IMRT coupled with noninvasive body frames (stereotactic and image-guided) for multifractionated radiotherapy. Methods and Materials: The Memorial Sloan-Kettering Cancer Center (Memorial) stereotactic body frame (MSBF) and Memorial body cradle (MBC) have been developed as noninvasive immobilizing devices for paraspinal IMRT using stereotactic (MSBF) and image-guided (MBC) techniques. Patients were either previously irradiated or prescribed doses beyond spinal cord tolerance (54 Gy in standard fractionation) and had unresectable gross disease involving the spinal canal. The planning target volume (PTV) was the gross tumor volume with a 1 cm margin. The PTV was not allowed to include the spinal cord contour. All treatment planning was performed using software developed within the institution. Isocenter verification was performed with an in-room computed tomography scan (MSBF) or electronic portal imaging devices, or both. Patients were followed up with serial magnetic resonance imaging every 3-4 months, and no patients were lost to follow-up. Kaplan-Meier statistics were used for analysis of clinical data. Results: Both the MSBF and MBC were able to provide setup accuracy within 2 mm. With a median follow-up of 11 months, 35 patients (14 primary and 21 secondary malignancies) underwent treatment. The median dose previously received was 3000 cGy in 10 fractions. The median dose prescribed for these patients was 2000 cGy/5 fractions (2000-3000 cGy), which provided a median PTV V100 of 88%. In previously unirradiated patients, the median prescribed dose was 7000 cGy (5940-7000 cGy) with a median PTV V100 of 90%. The median Dmax to the cord was 34% and 68% for previously irradiated and never

  7. Comparison of forward planning with automated inverse planning for three-dimensional conformal radiotherapy of non-small cell lung cancer without IMRT

    International Nuclear Information System (INIS)

    Mendes, Ruheena; Lavrenkov, Konstantin; Bedford, James L.; Henrys, Anthony; Ashley, Sue; Brada, Michael

    2006-01-01

    The forward and inverse treatment plans of 10 patients with lung cancer were compared in terms of PTV coverage, sparing of normal lung and time required to generate a plan. The inverse planning produced as good treatment plans as an experienced dosimetrist with considerable reduction in staff time. When translated to other complex sites, inverse non-IMRT planning may have considerable impact on manpower requirements

  8. Stereotactic Image-Guided Intensity Modulated Radiotherapy Using the HI-ART II Helical Tomotherapy System

    International Nuclear Information System (INIS)

    Holmes, Timothy W.; Hudes, Richard; Dziuba, Sylwester; Kazi, Abdul; Hall, Mark; Dawson, Dana

    2008-01-01

    The highly integrated adaptive radiation therapy (HI-ART II) helical tomotherapy unit is a new radiotherapy machine designed to achieve highly precise and accurate treatments at all body sites. The precision and accuracy of the HI-ART II is similar to that provided by stereotactic radiosurgery systems, hence the historical distinction between external beam radiotherapy and stereotactic procedures based on differing precision requirements is removed for this device. The objectives of this work are: (1) to describe stereotactic helical tomotherapy processes (SRS, SBRT); (2) to show that the precision and accuracy of the HI-ART meet the requirements defined for SRS and SBRT; and (3) to describe the clinical implementation of a stereotactic image-guided intensity modulated radiation therapy (IG-IMRT) system that incorporates optical motion management

  9. SU-C-207A-07: Cumulative 18F-FDG Uptake Histogram Relative to Radiation Dose Volume Histogram of Lung After IMRT Or PSPT and Their Association with Radiation Pneumonitis

    International Nuclear Information System (INIS)

    Shusharina, N; Choi, N; Bortfeld, T; Liao, Z; Mohan, R

    2016-01-01

    Purpose: To determine whether the difference in cumulative 18F-FDG uptake histogram of lung treated with either IMRT or PSPT is associated with radiation pneumonitis (RP) in patients with inoperable stage II and III NSCLC. Methods: We analyzed 24 patients from a prospective randomized trial to compare IMRT (n=12) with vs. PSPT (n=12) for inoperable NSCLC. All patients underwent PET-CT imaging between 35 and 88 days post-therapy. Post-treatment PET-CT was aligned with planning 4D CT to establish a voxel-to-voxel correspondence between post-treatment PET and planning dose images. 18F-FDG uptake as a function of radiation dose to normal lung was obtained for each patient. Distribution of the standard uptake value (SUV) was analyzed using a volume histogram method. The image quantitative characteristics and DVH measures were correlated with clinical symptoms of pneumonitis. Results: Patients with RP were present in both groups: 5 in the IMRT and 6 in the PSPT. The analysis of cumulative SUV histograms showed significantly higher relative volumes of the normal lung having higher SUV uptake in the PSPT patients for both symptomatic and asymptomatic cases (VSUV=2: 10% for IMRT vs 16% for proton RT and VSUV=1: 10% for IMRT vs 23% for proton RT). In addition, the SUV histograms for symptomatic cases in PSPT patients exhibited a significantly longer tail at the highest SUV. The absolute volume of the lung receiving the dose >70 Gy was larger in the PSPT patients. Conclusion: 18F-FDG uptake – radiation dose response correlates with RP in both groups of patients by means of the linear regression slope. SUV is higher for the PSPT patients for both symptomatic and asymptomatic cases. Higher uptake after PSPT patients is explained by larger volumes of the lung receiving high radiation dose.

  10. Phantom-to-clinic development of hypofractionated stereotactic body radiotherapy for early-stage glottic laryngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Chuxiong [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Chun, Stephen G. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Sumer, Baran D. [Department of Otolaryngology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Nedzi, Lucien A.; Abdulrahman, Ramzi E. [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Yordy, John S. [Valley Radiation Therapy Center, Anchorage, AK (United States); Lee, Pam; Hrycushko, Brian [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Solberg, Timothy D. [Department of Radiation Oncology, Abramson Comprehensive Cancer Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA (United States); Ahn, Chul [Department of Clinical Sciences, University of Texas Southwestern Medical Center, Dallas, TX (United States); Timmerman, Robert D. [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Schwartz, David L., E-mail: david.schwartz214@gmail.com [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States)

    2017-07-01

    The purpose of this study was to commission and clinically test a robotic stereotactic delivery system (CyberKnife, Sunnyvale, CA) to treat early-stage glottic laryngeal cancer. We enrolled 15 patients with cTis-T2N0M0 carcinoma of the glottic larynx onto an institutional review board (IRB)-approved clinical trial. Stereotactic body radiotherapy (SBRT) plans prescribed 45 Gy/10 fractions to the involved hemilarynx. SBRT dosimetry was compared with (1) standard carotid-sparing laryngeal intensity-modulated radiation therapy (IMRT) and (2) selective hemilaryngeal IMRT. Our results demonstrate that SBRT plans improved sparing of the contralateral arytenoid (mean 20.0 Gy reduction, p <0.001), ipsilateral carotid D{sub max} (mean 20.6 Gy reduction, p <0.001), contralateral carotid D{sub max} (mean 28.1 Gy reduction, p <0.001), and thyroid D{sub mean} (mean 15.0 Gy reduction, p <0.001) relative to carotid-sparing IMRT. SBRT also modestly improved dose sparing to the contralateral arytenoid (mean 4.8 Gy reduction, p = 0.13) and spinal cord D{sub max} (mean 4.9 Gy reduction, p = 0.015) relative to selective hemilaryngeal IMRT plans. This “phantom-to-clinic” feasibility study confirmed that hypofractionated SBRT treatment for early-stage laryngeal cancer can potentially spare dose to adjacent normal tissues relative to current IMRT standards. Clinical efficacy and toxicity correlates continue to be collected through an ongoing prospective trial.

  11. 4D imaging for target definition in stereotactic radiotherapy for lung cancer.

    Science.gov (United States)

    Slotman, Ben J; Lagerwaard, Frank J; Senan, Suresh

    2006-01-01

    Stereotactic radiotherapy of Stage I lung tumors has been reported to result in high local control rates that are far superior to those obtained with conventional radiotherapy techniques, and which approach those achieved with primary surgery. Breathing-induced motion of tumor and target tissues is an important issue in this technique and careful attention should be paid to the contouring and the generation of individualized margins. We describe our experience with the use of 4DCT scanning for this group of patients, the use of post-processing tools and the potential benefits of respiratory gating.

  12. [Comparison of dose calculation algorithms in stereotactic radiation therapy in lung].

    Science.gov (United States)

    Tomiyama, Yuki; Araki, Fujio; Kanetake, Nagisa; Shimohigashi, Yoshinobu; Tominaga, Hirofumi; Sakata, Jyunichi; Oono, Takeshi; Kouno, Tomohiro; Hioki, Kazunari

    2013-06-01

    Dose calculation algorithms in radiation treatment planning systems (RTPSs) play a crucial role in stereotactic body radiation therapy (SBRT) in the lung with heterogeneous media. This study investigated the performance and accuracy of dose calculation for three algorithms: analytical anisotropic algorithm (AAA), pencil beam convolution (PBC) and Acuros XB (AXB) in Eclipse (Varian Medical Systems), by comparison against the Voxel Monte Carlo algorithm (VMC) in iPlan (BrainLab). The dose calculations were performed with clinical lung treatments under identical planning conditions, and the dose distributions and the dose volume histogram (DVH) were compared among algorithms. AAA underestimated the dose in the planning target volume (PTV) compared to VMC and AXB in most clinical plans. In contrast, PBC overestimated the PTV dose. AXB tended to slightly overestimate the PTV dose compared to VMC but the discrepancy was within 3%. The discrepancy in the PTV dose between VMC and AXB appears to be due to differences in physical material assignments, material voxelization methods, and an energy cut-off for electron interactions. The dose distributions in lung treatments varied significantly according to the calculation accuracy of the algorithms. VMC and AXB are better algorithms than AAA for SBRT.

  13. Prospective study on stereotactic radiotherapy of limited-stage non-small-cell lung cancer

    DEFF Research Database (Denmark)

    Høyer, Morten; Roed, Henrik; Hansen, Anders Traberg

    2006-01-01

    Purpose: To test the effect of stereotactic body radiotherapy (SBRT) in       the treatment of medically inoperable patients with limited-stage       non-small-cell lung cancer (NSCLC) in a Phase II trial. Methods and       Materials: Forty patients with Stage I NSCLC were treated with SBRT...... resulted in a high       probability of local control and a promising survival rate. The toxicity       after SBRT of lung tumors was moderate. However, deterioration in       performance status, respiratory insufficiency, and other side effects were       observed...

  14. A Method for Correcting IMRT Optimizer Heterogeneity Dose Calculations

    International Nuclear Information System (INIS)

    Zacarias, Albert S.; Brown, Mellonie F.; Mills, Michael D.

    2010-01-01

    Radiation therapy treatment planning for volumes close to the patient's surface, in lung tissue and in the head and neck region, can be challenging for the planning system optimizer because of the complexity of the treatment and protected volumes, as well as striking heterogeneity corrections. Because it is often the goal of the planner to produce an isodose plan with uniform dose throughout the planning target volume (PTV), there is a need for improved planning optimization procedures for PTVs located in these anatomical regions. To illustrate such an improved procedure, we present a treatment planning case of a patient with a lung lesion located in the posterior right lung. The intensity-modulated radiation therapy (IMRT) plan generated using standard optimization procedures produced substantial dose nonuniformity across the tumor caused by the effect of lung tissue surrounding the tumor. We demonstrate a novel iterative method of dose correction performed on the initial IMRT plan to produce a more uniform dose distribution within the PTV. This optimization method corrected for the dose missing on the periphery of the PTV and reduced the maximum dose on the PTV to 106% from 120% on the representative IMRT plan.

  15. Evaluation of heterogeneity corrections in stereotactic body radiation therapy for the lung

    International Nuclear Information System (INIS)

    Matsuo, Yukinori; Narita, Yuichiro; Nakata, Manabu

    2008-01-01

    The purpose was to evaluate impact of heterogeneity corrections on dose distributions for stereotactic body radiation therapy (SBRT) for the lung. This study was conducted with the treatment plans of 28 cases in which we performed SBRT for solitary lung tumors with 48 Gy in 12-Gy fractions at the isocenter. The treatment plans were recalculated under three conditions of heterogeneity correction as follows: pencil beam convolution with Batho power law correction (PBC-BPL), pencil beam convolution with no correction (PBC-NC), and anisotropic analytical algorithm with heterogeneity correction (AAA). Dose-volumetric data were compared among the three conditions. Heterogeneity corrections had a significant impact on all dose-volumetric parameters. Means of isocenter dose were 48.0 Gy, 44.6 Gy, and 48.4 Gy in PBC-BPL, PBC-NC, and AAA, respectively. PTV D95 were 45.2 Gy, 41.1 Gy, and 42.1 Gy, and V20 of the lung were 4.1%, 3.7%, and 3.9%, respectively. Significant differences in dose distribution were observed among heterogeneity corrections. Attention needs to be paid to the differences. (author)

  16. EF5 PET of Tumor Hypoxia: A Predictive Imaging Biomarker of Response to Stereotactic Ablative Radiotherapy (SABR) for Early Lung Cancer

    Science.gov (United States)

    2017-11-01

    SABR) for Early Lung Cancer PRINCIPAL INVESTIGATOR: Billy W Loo Jr, MD PhD CONTRACTING ORGANIZATION: The Leland Stanford Junior University...Response to Stereotactic Ablative Radiotherapy (SABR) for Early Lung Cancer 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Billy W Loo Jr, MD...for early stage lung cancer in patients who are not candidates for surgery because of excessive surgical risk, and will be an important treatment option

  17. Adaptive Stereotactic Body Radiation Therapy Planning for Lung Cancer

    International Nuclear Information System (INIS)

    Qin, Yujiao; Zhang, Fan; Yoo, David S.; Kelsey, Chris R.; Yin, Fang-Fang; Cai, Jing

    2013-01-01

    Purpose: To investigate the dosimetric effects of adaptive planning on lung stereotactic body radiation therapy (SBRT). Methods and Materials: Forty of 66 consecutive lung SBRT patients were selected for a retrospective adaptive planning study. CBCT images acquired at each fraction were used for treatment planning. Adaptive plans were created using the same planning parameters as the original CT-based plan, with the goal to achieve comparable comformality index (CI). For each patient, 2 cumulative plans, nonadaptive plan (P NON ) and adaptive plan (P ADP ), were generated and compared for the following organs-at-risks (OARs): cord, esophagus, chest wall, and the lungs. Dosimetric comparison was performed between P NON and P ADP for all 40 patients. Correlations were evaluated between changes in dosimetric metrics induced by adaptive planning and potential impacting factors, including tumor-to-OAR distances (d T-OAR ), initial internal target volume (ITV 1 ), ITV change (ΔITV), and effective ITV diameter change (Δd ITV ). Results: 34 (85%) patients showed ITV decrease and 6 (15%) patients showed ITV increase throughout the course of lung SBRT. Percentage ITV change ranged from −59.6% to 13.0%, with a mean (±SD) of −21.0% (±21.4%). On average of all patients, P ADP resulted in significantly (P=0 to .045) lower values for all dosimetric metrics. Δd ITV /d T-OAR was found to correlate with changes in dose to 5 cc (ΔD5cc) of esophagus (r=0.61) and dose to 30 cc (ΔD30cc) of chest wall (r=0.81). Stronger correlations between Δd ITV /d T-OAR and ΔD30cc of chest wall were discovered for peripheral (r=0.81) and central (r=0.84) tumors, respectively. Conclusions: Dosimetric effects of adaptive lung SBRT planning depend upon target volume changes and tumor-to-OAR distances. Adaptive lung SBRT can potentially reduce dose to adjacent OARs if patients present large tumor volume shrinkage during the treatment

  18. Adaptive Stereotactic Body Radiation Therapy Planning for Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Qin, Yujiao [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Zhang, Fan [Occupational and Environmental Safety Office, Duke University Medical Center, Durham, North Carolina (United States); Yoo, David S.; Kelsey, Chris R. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Yin, Fang-Fang [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Cai, Jing, E-mail: jing.cai@duke.edu [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States)

    2013-09-01

    Purpose: To investigate the dosimetric effects of adaptive planning on lung stereotactic body radiation therapy (SBRT). Methods and Materials: Forty of 66 consecutive lung SBRT patients were selected for a retrospective adaptive planning study. CBCT images acquired at each fraction were used for treatment planning. Adaptive plans were created using the same planning parameters as the original CT-based plan, with the goal to achieve comparable comformality index (CI). For each patient, 2 cumulative plans, nonadaptive plan (P{sub NON}) and adaptive plan (P{sub ADP}), were generated and compared for the following organs-at-risks (OARs): cord, esophagus, chest wall, and the lungs. Dosimetric comparison was performed between P{sub NON} and P{sub ADP} for all 40 patients. Correlations were evaluated between changes in dosimetric metrics induced by adaptive planning and potential impacting factors, including tumor-to-OAR distances (d{sub T-OAR}), initial internal target volume (ITV{sub 1}), ITV change (ΔITV), and effective ITV diameter change (Δd{sub ITV}). Results: 34 (85%) patients showed ITV decrease and 6 (15%) patients showed ITV increase throughout the course of lung SBRT. Percentage ITV change ranged from −59.6% to 13.0%, with a mean (±SD) of −21.0% (±21.4%). On average of all patients, P{sub ADP} resulted in significantly (P=0 to .045) lower values for all dosimetric metrics. Δd{sub ITV}/d{sub T-OAR} was found to correlate with changes in dose to 5 cc (ΔD5cc) of esophagus (r=0.61) and dose to 30 cc (ΔD30cc) of chest wall (r=0.81). Stronger correlations between Δd{sub ITV}/d{sub T-OAR} and ΔD30cc of chest wall were discovered for peripheral (r=0.81) and central (r=0.84) tumors, respectively. Conclusions: Dosimetric effects of adaptive lung SBRT planning depend upon target volume changes and tumor-to-OAR distances. Adaptive lung SBRT can potentially reduce dose to adjacent OARs if patients present large tumor volume shrinkage during the treatment.

  19. (18)F-FDG PET during stereotactic body radiotherapy for stage I lung tumours cannot predict outcome : a pilot study

    NARCIS (Netherlands)

    Wiegman, Erwin M.; Pruim, Jan; Ubbels, Jan F.; Groen, Harry J. M.; Langendijk, Johannes A.; Widder, Joachim

    (18)F-Fluorodeoxyglucose positron emission tomography (FDG PET) has been used to assess metabolic response several months after stereotactic body radiotherapy (SBRT) for early-stage non-small cell lung cancer. However, whether a metabolic response can be observed already during treatment and thus

  20. Hybrid IMRT plans-concurrently treating conventional and IMRT beams for improved breast irradiation and reduced planning time

    International Nuclear Information System (INIS)

    Mayo, Charles S.; Urie, Marcia M.; Fitzgerald, Thomas J.

    2005-01-01

    Purpose: To evaluate a hybrid intensity modulated radiation therapy (IMRT) technique as a class solution for treatment of the intact breast. Methods and materials: The following five plan techniques were compared for 10 breast patients using dose-volume histogram analysis: conventional wedged-field tangents (Tangents), forward-planned field-within-a-field tangents (FIF), IMRT-only tangents (IMRT tangents), conventional open plus IMRT tangents (4-field hybrid), and conventional open plus IMRT tangents with 2 anterior oblique IMRT beams (6-field hybrid). Results: The 4-field hybrid and FIF achieved dose distributions better than Tangents and IMRT tangents. The volume of tissue outside the planning target volume receiving ≥110% of prescribed dose was largest for IMRT tangents (average 158 cc) and least for 6-field hybrid (average 1 cc); the FIF and 4-field hybrid were comparable (average 15 cc). Heart volume ≥30 Gy averaged 13 cc for all techniques, except Tangents, for which it was 32 cc. Average total lung volume ≥20 Gy was 7% for all. Contralateral breast doses were < 3% for all. Planning time for hybrid techniques was significantly less than for conventional FIF technique. Conclusions: The 4-field hybrid technique is a viable class solution. The 6-field hybrid technique creates the most conformal dose distribution at the expense of more normal tissue receiving low dose

  1. TH-EF-204-04: Experience of IMRT and Other Conformal Techniques in Russia

    International Nuclear Information System (INIS)

    Krylova, T.

    2016-01-01

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  2. TH-EF-204-04: Experience of IMRT and Other Conformal Techniques in Russia

    Energy Technology Data Exchange (ETDEWEB)

    Krylova, T. [Russian Research Cancer Center (Russian Federation)

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  3. Dosimetric Comparison of Real-Time MRI-Guided Tri-Cobalt-60 Versus Linear Accelerator-Based Stereotactic Body Radiation Therapy Lung Cancer Plans.

    Science.gov (United States)

    Wojcieszynski, Andrzej P; Hill, Patrick M; Rosenberg, Stephen A; Hullett, Craig R; Labby, Zacariah E; Paliwal, Bhudatt; Geurts, Mark W; Bayliss, R Adam; Bayouth, John E; Harari, Paul M; Bassetti, Michael F; Baschnagel, Andrew M

    2017-06-01

    Magnetic resonance imaging-guided radiation therapy has entered clinical practice at several major treatment centers. Treatment of early-stage non-small cell lung cancer with stereotactic body radiation therapy is one potential application of this modality, as some form of respiratory motion management is important to address. We hypothesize that magnetic resonance imaging-guided tri-cobalt-60 radiation therapy can be used to generate clinically acceptable stereotactic body radiation therapy treatment plans. Here, we report on a dosimetric comparison between magnetic resonance imaging-guided radiation therapy plans and internal target volume-based plans utilizing volumetric-modulated arc therapy. Ten patients with early-stage non-small cell lung cancer who underwent radiation therapy planning and treatment were studied. Following 4-dimensional computed tomography, patient images were used to generate clinically deliverable plans. For volumetric-modulated arc therapy plans, the planning tumor volume was defined as an internal target volume + 0.5 cm. For magnetic resonance imaging-guided plans, a single mid-inspiratory cycle was used to define a gross tumor volume, then expanded 0.3 cm to the planning tumor volume. Treatment plan parameters were compared. Planning tumor volumes trended larger for volumetric-modulated arc therapy-based plans, with a mean planning tumor volume of 47.4 mL versus 24.8 mL for magnetic resonance imaging-guided plans ( P = .08). Clinically acceptable plans were achievable via both methods, with bilateral lung V20, 3.9% versus 4.8% ( P = .62). The volume of chest wall receiving greater than 30 Gy was also similar, 22.1 versus 19.8 mL ( P = .78), as were all other parameters commonly used for lung stereotactic body radiation therapy. The ratio of the 50% isodose volume to planning tumor volume was lower in volumetric-modulated arc therapy plans, 4.19 versus 10.0 ( P guided tri-cobalt-60 radiation therapy is capable of delivering lung high

  4. 4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

    International Nuclear Information System (INIS)

    Dong, Peng; Lee, Percy; Ruan, Dan; Long, Troy; Romeijn, Edwin; Low, Daniel A.; Kupelian, Patrick; Abraham, John; Yang, Yingli; Sheng, Ke

    2013-01-01

    Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R 50 was reduced by more than 50%. Lung V 20 , V 10 , and V 5 were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and

  5. 4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Peng; Lee, Percy; Ruan, Dan [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Long, Troy; Romeijn, Edwin [Department of Industrial and Operations Engineering, University of Michigan, Ann Arbor, Michigan (United States); Low, Daniel A.; Kupelian, Patrick; Abraham, John; Yang, Yingli [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Sheng, Ke, E-mail: ksheng@mednet.ucla.edu [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States)

    2013-07-01

    Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R{sub 50} was reduced by more than 50%. Lung V{sub 20}, V{sub 10}, and V{sub 5} were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor

  6. Stereotactic body radiation therapy (S.B.R.T.) for early-stage lung cancer

    International Nuclear Information System (INIS)

    Hiraok, M.; Matsuo, Y.; Nagata, Y.

    2007-01-01

    Stereotactic body radiation therapy (SBRT) is a new treatment modality for early stage non-small-cell lung cancer, and has been developed in the United States, the European Union, and Japan. We started a feasibility study of this therapy in July 1998, using a stereotactic body frame. The eligibility criteria for primary lung cancer were: 1) solitary tumor less than 4 cm (T1-3NOM); 2) inoperable, or the patient refused operation; 3) no necessity for oxygen support; 4) performance status equal to or less than 2; 5) the peripheral tumor which dose constraints of mediastinal organs are maintained. A total dose of 48 Gy was delivered in four fractions in 2 weeks in most patients. Lung toxicity was minimal. No grade II toxicities for spinal cord, bronchus, pulmonary artery, or esophagus were observed. The 3 years overall survival for 32 patients with stage IA, and 13 patients with stage IB were 83% and 72%, respectively. Only one local recurrence was observed in a follow-up of 6 1 months. We retrospectively analyzed 241 patients from 13 Japanese institutions. The local recurrence rate was 20% when the biological equivalent dose (BED) was less than 100 Gy, and 6.5% when the BED was over 100 Gy. Overall survival at 3 years was 42% when the BED was less than 100 Gy, and 46% when it was over 100 Gy. In tumors, which received a BED of more than 100 Gy, overall survival at 3 years was 91% for operable patients, and 50% for inoperable patients. Long-term results, in terms of local control, regional recurrence, survival, and complications, are not yet evaluated. However, this treatment modality is highly expected to be a standard treatment for inoperable patients, and it may be an alternative to lobectomy for operative patients. A prospective trial, which is now ongoing, will, answer these questions. (author)

  7. SU-E-T-49: Automatic Beam Angle Determination for Lung IMRT Planning Using a Beam Configuration Atlas

    International Nuclear Information System (INIS)

    Yuan, L; Yin, F; Sheng, Y; Wu, Q J.; Ge, Y; Li, Y

    2014-01-01

    Purpose: To present a technique to automatically determine beam angle configurations for lung IMRT planning based on the patient-specific anatomy and tumor geometry. Methods: The relationship between individual patient anatomy and proper beam configurations was learned from high quality clinical plans in three steps. First, a beam configuration atlas was obtained by classifying 60 lung IMRT plans into 6 beam configuration clusters based on a dissimilarity measure defined between different beam configurations. A beam configuration template was extracted from each cluster to form an atlas. Second, a beam efficiency index map (EI map) was constructed to characterize the geometry of the tumor relative to the lungs, the body and other OARs along each candidate beam direction. Finally, the EI maps of the clinical cases and the cluster assignments of their beam configurations were paired to train a Bayesian classification model. This technique was validated by leave-one-out cross validation with 16 cases randomly selected from the original dataset. An IMRT plan (autobeam plan) for each test case was generated using the beam configuration template according to the cluster assignment given by the model and was compared with the corresponding clinical plan. Results: The dosimetric parameters (mean±S.D. in percentage of prescription dose) in the auto-beam plans and in the clinical plans, respectively, and the p-values by a paired ttest (in parenthesis) are: lung Dmean: 16.3±9.3, 18.6±7.4 (0.48), esophagus Dmean: 28.4±18, 30.7±19.3 (0.02), Heart Dmean: 21.5±17.5,21.1±17.2 (0.76), Spinal Cord D2%: 48±23, 51.2±21.8 (0.01), PTV dose homogeneity (D2%–D99%): 22±27.4, 20.4±12.8 (0.10).The dose reductions by the autobeam plans in esophagus Dmean and cord D02 are statistically significant but the differences (<4%) may not be clinically significant. The other dosimetric parameters are not statistically different. Conclusion: Plans generated by the automatic beam angle

  8. Clinical characteristics and outcome of pneumothorax after stereotactic body radiotherapy for lung tumors.

    Science.gov (United States)

    Asai, Kaori; Nakamura, Katsumasa; Shioyama, Yoshiyuki; Sasaki, Tomonari; Matsuo, Yoshio; Ohga, Saiji; Yoshitake, Tadamasa; Terashima, Kotaro; Shinoto, Makoto; Matsumoto, Keiji; Hirata, Hidenari; Honda, Hiroshi

    2015-12-01

    We retrospectively investigated the clinical characteristics and outcome of pneumothorax after stereotactic body radiotherapy (SBRT) for lung tumors. Between April 2003 and July 2012, 473 patients with lung tumors were treated with SBRT. We identified 12 patients (2.5 %) with pneumothorax caused by SBRT, and evaluated the clinical features of pneumothorax. All of the tumors were primary lung cancers. The severity of radiation pneumonitis was grade 1 in 10 patients and grade 2 in two patients. Nine patients had emphysema. The planning target volume and pleura overlapped in 11 patients, and the tumors were attached to the pleura in 7 patients. Rib fractures were observed in three patients before or at the same time as the diagnosis of pneumothorax. The median time to onset of pneumothorax after SBRT was 18.5 months (4-84 months). The severity of pneumothorax was grade 1 in 11 patients and grade 3 in one patient. Although pneumothorax was a relatively rare late adverse effect after SBRT, some patients demonstrated pneumothorax after SBRT for peripheral lung tumors. Although most pneumothorax was generally tolerable and self-limiting, careful follow-up is needed.

  9. Tumor Volume-Adapted Dosing in Stereotactic Ablative Radiotherapy of Lung Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Trakul, Nicholas; Chang, Christine N.; Harris, Jeremy [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Chapman, Christopher [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of Michigan School of Medicine, Ann Arbor, MI (United States); Rao, Aarti [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of California, Davis, School of Medicine, Davis, CA (United States); Shen, John [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of California, Irvine, School of Medicine, Irvine, CA (United States); Quinlan-Davidson, Sean [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Department of Radiation Oncology, McMaster University, Juravinski Cancer Centre, Hamilton, Ontario (Canada); Filion, Edith J. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Departement de Medecine, Service de Radio-Oncologie, Centre Hospitalier de l' Universite de Montreal, Montreal, Quebec (Canada); Wakelee, Heather A.; Colevas, A. Dimitrios [Department of Medicine, Division of Oncology, Stanford University School of Medicine, Stanford, CA (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, CA (United States); Whyte, Richard I. [Department of Cardiothoracic Surgery, Division of General Thoracic Surgery, Stanford University School of Medicine, Stanford, CA (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, CA (United States); and others

    2012-09-01

    Purpose: Current stereotactic ablative radiotherapy (SABR) protocols for lung tumors prescribe a uniform dose regimen irrespective of tumor size. We report the outcomes of a lung tumor volume-adapted SABR dosing strategy. Methods and Materials: We retrospectively reviewed the outcomes in 111 patients with a total of 138 primary or metastatic lung tumors treated by SABR, including local control, regional control, distant metastasis, overall survival, and treatment toxicity. We also performed subset analysis on 83 patients with 97 tumors treated with a volume-adapted dosing strategy in which small tumors (gross tumor volume <12 mL) received single-fraction regimens with biologically effective doses (BED) <100 Gy (total dose, 18-25 Gy) (Group 1), and larger tumors (gross tumor volume {>=}12 mL) received multifraction regimens with BED {>=}100 Gy (total dose, 50-60 Gy in three to four fractions) (Group 2). Results: The median follow-up time was 13.5 months. Local control for Groups 1 and 2 was 91.4% and 92.5%, respectively (p = 0.24) at 12 months. For primary lung tumors only (excluding metastases), local control was 92.6% and 91.7%, respectively (p = 0.58). Regional control, freedom from distant metastasis, and overall survival did not differ significantly between Groups 1 and 2. Rates of radiation pneumonitis, chest wall toxicity, and esophagitis were low in both groups, but all Grade 3 toxicities developed in Group 2 (p = 0.02). Conclusion: A volume-adapted dosing approach for SABR of lung tumors seems to provide excellent local control for both small- and large-volume tumors and may reduce toxicity.

  10. Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT and Arc technique for esophageal carcinoma

    International Nuclear Information System (INIS)

    Martin, Spencer; Chen, Jeff Z.; Rashid Dar, A.; Yartsev, Slav

    2011-01-01

    Purpose: To compare radiotherapy treatment plans for mid- and distal-esophageal cancer with primary involvement of the gastroesophageal (GE) junction using a novel IMRT and Arc technique (IMRT and Arc), helical tomotherapy (HT), and RapidArc (RA1 and RA2). Methods and materials: Eight patients treated on HT for locally advanced esophageal cancer with radical intent were re-planned for RA and IMRT and Arc. RA plans employed single and double arcs (RA1 and RA2, respectively), while IMRT and Arc plans had four fixed-gantry IMRT fields and a conformal arc. Dose-volume histogram statistics, dose uniformity, and dose homogeneity were analyzed to compare treatment plans. Results: RA2 plans showed significant improvement over RA1 plans in terms of OAR dose and PTV dose uniformity and homogeneity. HT plan provided best dose uniformity (p = 0.001) and dose homogeneity (p = 0.002) to planning target volume (PTV), while IMRT and Arc and RA2 plans gave lowest dose to lungs among four radiotherapy techniques with acceptable PTV dose coverage. Mean V 10 of the lungs was significantly reduced by the RA2 plans compared to IMRT and Arc (40.3%, p = 0.001) and HT (66.2%, p 15 of the lungs for the RA2 plans also showed significant improvement over the IMRT and Arc (25.2%, p = 0.042) and HT (34.8%, p = 0.027) techniques. These improvements came at the cost of higher doses to the heart volume compared to HT and IMRT and Arc techniques. Mean lung dose (MLD) for the IMRT and Arc technique (21.2 ± 5.0% of prescription dose) was significantly reduced compared to HT (26.3%, p = 0.004), RA1 (23.3%, p = 0.028), and RA2 (23.2%, p = 0.017) techniques. Conclusion: The IMRT and Arc technique is a good option for treating esophageal cancer with thoracic involvement. It achieved optimal low dose to the lungs and heart with acceptable PTV coverage. HT is a good option for treating esophageal cancer with little thoracic involvement as it achieves superior dose conformality and uniformity. The RA2

  11. Effect of image-guided hypofractionated stereotactic radiotherapy on peripheral non-small-cell lung cancer

    Directory of Open Access Journals (Sweden)

    Wang SW

    2016-08-01

    Full Text Available Shu-wen Wang,1 Juan Ren,1 Yan-li Yan,2 Chao-fan Xue,2 Li Tan,2 Xiao-wei Ma2 1Department of Radiotherapy, First Affiliated Hospital of Xian Jiaotong University, 2Medical School of Xian Jiaotong University, Xi’an, Shaanxi, People’s Republic of China Abstract: The objective of this study was to compare the effects of image-guided hypofractionated radiotherapy and conventional fractionated radiotherapy on non-small-cell lung cancer (NSCLC. Fifty stage- and age-matched cases with NSCLC were randomly divided into two groups (A and B. There were 23 cases in group A and 27 cases in group B. Image-guided radiotherapy (IGRT and stereotactic radiotherapy were conjugately applied to the patients in group A. Group A patients underwent hypofractionated radiotherapy (6–8 Gy/time three times per week, with a total dose of 64–66 Gy; group B received conventional fractionated radiotherapy, with a total dose of 68–70 Gy five times per week. In group A, 1-year and 2-year local failure survival rate and 1-year local failure-free survival rate were significantly higher than in group B (P<0.05. The local failure rate (P<0.05 and distant metastasis rate (P>0.05 were lower in group A than in group B. The overall survival rate of group A was significantly higher than that of group B (P=0.03, and the survival rate at 1 year was 87% vs 63%, (P<0.05. The median survival time of group A was longer than that of group B. There was no significant difference in the incidence of complications between the two groups (P>0.05. Compared with conventional fractionated radiation therapy, image-guided hypofractionated stereotactic radiotherapy in NSCLC received better treatment efficacy and showed good tolerability. Keywords: non-small-cell lung cancer, hypofractionated radiotherapy, stereotactic radiotherapy, segmentation, intensity-modulated radiotherapy, image-guided radiation therapy technology

  12. Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysis

    International Nuclear Information System (INIS)

    McGrath, Samuel D.; Matuszak, Martha M.; Yan Di; Kestin, Larry L.; Martinez, Alvaro A.; Grills, Inga S.

    2010-01-01

    Purpose/objective(s): Volumetric modulated arc therapy (VMAT) allows for intensity-modulated radiation delivery during gantry rotation with dynamic MLC motion, variable dose rates and gantry speed modulation. We compared VMAT plans with 3D-CRT for hypofractionated lung radiotherapy. Materials/methods: Twenty-one 3D-CRT plans for Stage IA lung cancer previously treated stereotactically were selected. VMAT plans were generated by optimizing machine aperture shape and radiation intensity at 10 deg. intervals. A partial arc range of 180 deg. was manually selected to coincide with tumor location. The arc was resampled down to 5 deg. intervals to ensure dose calculation accuracy. Identical planning objectives were used for VMAT/3D-CRT. Parameters assessed included dose to PTV and organs-at-risk (OAR), monitor units, and multiple conformity and homogeneity indices. Plans were delivered to a phantom for time comparison. Results: Lung V 20/12.5/10/5 were less with VMAT (relative reduction 4.5%, p = .02; 3.2%, p = .01; 2.6%, p = .01; 4.2%, p = .03, respectively). Mean/maximum-doses to PTV, dose to additional OARs, 95% isodose line conformity, and target volume homogeneity were equivalent. VMAT improved conformity at both the 80% (1.87 vs. 1.93, p = .08) and 50% isodose lines (5.19 vs. 5.65, p = .01). Treatment times were reduced significantly with VMAT (mean 6.1 vs. 11.9 min, p < .01). Conclusions: Single arc VMAT planning achieves highly conformal dose distributions while controlling dose to critical structures, including significant reduction in lung dose volume parameters. Employing a VMAT technique decreases treatment times by 37-63%, reducing the chance of error introduced by intrafraction variation. The quality and efficiency of VMAT is ideally suited for stereotactic lung radiotherapy delivery.

  13. Radical stereotactic radiosurgery with real-time tumor motion tracking in the treatment of small peripheral lung tumors

    Directory of Open Access Journals (Sweden)

    Chang Thomas

    2007-10-01

    Full Text Available Abstract Background Recent developments in radiotherapeutic technology have resulted in a new approach to treating patients with localized lung cancer. We report preliminary clinical outcomes using stereotactic radiosurgery with real-time tumor motion tracking to treat small peripheral lung tumors. Methods Eligible patients were treated over a 24-month period and followed for a minimum of 6 months. Fiducials (3–5 were placed in or near tumors under CT-guidance. Non-isocentric treatment plans with 5-mm margins were generated. Patients received 45–60 Gy in 3 equal fractions delivered in less than 2 weeks. CT imaging and routine pulmonary function tests were completed at 3, 6, 12, 18, 24 and 30 months. Results Twenty-four consecutive patients were treated, 15 with stage I lung cancer and 9 with single lung metastases. Pneumothorax was a complication of fiducial placement in 7 patients, requiring tube thoracostomy in 4. All patients completed radiation treatment with minimal discomfort, few acute side effects and no procedure-related mortalities. Following treatment transient chest wall discomfort, typically lasting several weeks, developed in 7 of 11 patients with lesions within 5 mm of the pleura. Grade III pneumonitis was seen in 2 patients, one with prior conventional thoracic irradiation and the other treated with concurrent Gefitinib. A small statistically significant decline in the mean % predicted DLCO was observed at 6 and 12 months. All tumors responded to treatment at 3 months and local failure was seen in only 2 single metastases. There have been no regional lymph node recurrences. At a median follow-up of 12 months, the crude survival rate is 83%, with 3 deaths due to co-morbidities and 1 secondary to metastatic disease. Conclusion Radical stereotactic radiosurgery with real-time tumor motion tracking is a promising well-tolerated treatment option for small peripheral lung tumors.

  14. In vivo portal dosimetry for head-and-neck VMAT and lung IMRT: Linking γ-analysis with differences in dose–volume histograms of the PTV

    International Nuclear Information System (INIS)

    Rozendaal, Roel Arthur; Mijnheer, Ben J.; Herk, Marcel van; Mans, Anton

    2014-01-01

    Purpose: To relate the results of γ-analysis and dose–volume histogram (DVH) analysis of the PTV for detecting dose deviations with in vivo dosimetry for two treatment sites. Methods and materials: In vivo 3D dose distributions were reconstructed for 722 fractions of 200 head-and-neck (H and N) VMAT treatments and 183 fractions of 61 lung IMRT plans. The reconstructed and planned dose distributions in the PTV were compared using (a) the γ-distribution and (b) the differences in D2, D50 and D98 between the two dose distributions. Using pre-defined tolerance levels, all fractions were classified as deviating or not deviating by both methods. The mutual agreement, the sensitivity and the specificity of the two methods were compared. Results: For lung IMRT, the classification of the fractions was nearly identical for γ- and DVH-analyses of the PTV (94% agreement) and the sensitivity and specificity were comparable for both methods. Less agreement (80%) was found for H and N VMAT, while γ-analysis was both less sensitive and less specific. Conclusions: DVH- and γ-analyses perform nearly equal in finding dose deviations in the PTV for lung IMRT treatments; for H and N VMAT treatments, DVH-analysis is preferable. As a result of this study, a smooth transition to using DVH-analysis clinically for detecting in vivo dose deviations in the PTV is within reach

  15. The clinical results of stereotactic irradiation for stage IA non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Matsuura, Kanji; Kodama, Hisayuki; Murakami, Yuji; Kenjo, Masahiro; Kaneyasu, Yuko; Wadasaki, Koichi; Ito, Katsuhide; Kimura, Tomoki; Akagi, Yukio

    2006-01-01

    Discussed are the results in the title in authors' hospital. Subjects are 15 patients with the stage IA non-small cell lung cancer (10 males and 5 females; median age, 77 y; 11 cases of adenocarcinoma and 4 of squamous cell carcinoma), whose progress could be followed for 6 months or longer after the stereotactic irradiation during the period of July 1999 to 2006. The 8-9-gated irradiation therapy on the primary cancer alone was conducted with Varian Clinac 2300 (6MV-Xray) with the 3D planning equipment of PHILIPS Pinnacle. For some patients, the spirometer was used to monitor the voluntary breath-hold and body was fixed by vacuum fixer. Doses were 56 (4 Gy x 14) Gy in 3 cases, 60 (7.5 Gy x 8) Gy in 2, 50 (10 Gy x 5) Gy in 1 and 48 (12 Gy x 4) Gy in 9. Kaplan-Meier method was used for calculating the local control and survival rates. The former was 93% and the latter, 86% (1 year), 78% (2 y) and 39% (3 y). Three-year survival rate was 100% in 5 cases without other cancer and 18% in 10 with the cancers. Recurrence was seen in 3 cases and remote metastases, 7. Pneumonitis less than Grade 2 was in 11 cases. The stereotactic irradiation was thus found safe and effective in the stage IA non-small cell lung cancer. (T.I.)

  16. Target migration from re-inflation of adjacent atelectasis during lung stereotactic body radiotherapy.

    Science.gov (United States)

    Mao, Bijing; Verma, Vivek; Zheng, Dandan; Zhu, Xiaofeng; Bennion, Nathan R; Bhirud, Abhijeet R; Poole, Maria A; Zhen, Weining

    2017-06-10

    Stereotactic body radiotherapy (SBRT) is a widely accepted option for the treatment of medically inoperable early-stage non-small cell lung cancer (NSCLC). Herein, we highlight the importance of interfraction image guidance during SBRT. We describe a case of early-stage NSCLC associated with segmental atelectasis that translocated 15 mm anteroinferiorly due to re-expansion of the adjacent segmental atelectasis following the first fraction. The case exemplifies the importance of cross-sectional image-guided radiotherapy that shows the intended target, as opposed to aligning based on rigid anatomy alone, especially in cases associated with potentially "volatile" anatomic areas.

  17. Reducing dose to the lungs through loosing target dose homogeneity requirement for radiotherapy of non small cell lung cancer.

    Science.gov (United States)

    Miao, Junjie; Yan, Hui; Tian, Yuan; Ma, Pan; Liu, Zhiqiang; Li, Minghui; Ren, Wenting; Chen, Jiayun; Zhang, Ye; Dai, Jianrong

    2017-11-01

    It is important to minimize lung dose during intensity-modulated radiation therapy (IMRT) of nonsmall cell lung cancer (NSCLC). In this study, an approach was proposed to reduce lung dose by relaxing the constraint of target dose homogeneity during treatment planning of IMRT. Ten NSCLC patients with lung tumor on the right side were selected. The total dose for planning target volume (PTV) was 60 Gy (2 Gy/fraction). For each patient, two IMRT plans with six beams were created in Pinnacle treatment planning system. The dose homogeneity of target was controlled by constraints on the maximum and uniform doses of target volume. One IMRT plan was made with homogeneous target dose (the resulting target dose was within 95%-107% of the prescribed dose), while another IMRT plan was made with inhomogeneous target dose (the resulting target dose was more than 95% of the prescribed dose). During plan optimization, the dose of cord and heart in two types of IMRT plans were kept nearly the same. The doses of lungs, PTV and organs at risk (OARs) between two types of IMRT plans were compared and analyzed quantitatively. For all patients, the lung dose was decreased in the IMRT plans with inhomogeneous target dose. On average, the mean dose, V5, V20, and V30 of lung were reduced by 1.4 Gy, 4.8%, 3.7%, and 1.7%, respectively, and the dose to normal tissue was also reduced. These reductions in DVH values were all statistically significant (P target dose could protect lungs better and may be considered as a choice for treating NSCLC. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  18. A Phase 1 Trial of an Immune Checkpoint Inhibitor plus Stereotactic Ablative Radiotherapy in Patients with Inoperable Stage I Non-Small Cell Lung Cancer

    Science.gov (United States)

    2017-10-01

    with Inoperable Stage I Non-Small Cell Lung Cancer PRINCIPAL INVESTIGATOR: Karen Kelly, MD CONTRACTING ORGANIZATION: University of California...Inhibitor plus Stereotactic Ablative Radiotherapy in Patients with Inoperable Stage I Non-Small Cell Lung Cancer 5b. GRANT NUMBER W81XWH-15-2-0063...immune checkpoint inhibitor MPDL3280A (atezolizumab) in early stage inoperable non-small cell lung cancer . The trial is comprised of a traditional 3 + 3

  19. Tumor Volume-Adapted Dosing in Stereotactic Ablative Radiotherapy of Lung Tumors

    International Nuclear Information System (INIS)

    Trakul, Nicholas; Chang, Christine N.; Harris, Jeremy; Chapman, Christopher; Rao, Aarti; Shen, John; Quinlan-Davidson, Sean; Filion, Edith J.; Wakelee, Heather A.; Colevas, A. Dimitrios; Whyte, Richard I.

    2012-01-01

    Purpose: Current stereotactic ablative radiotherapy (SABR) protocols for lung tumors prescribe a uniform dose regimen irrespective of tumor size. We report the outcomes of a lung tumor volume-adapted SABR dosing strategy. Methods and Materials: We retrospectively reviewed the outcomes in 111 patients with a total of 138 primary or metastatic lung tumors treated by SABR, including local control, regional control, distant metastasis, overall survival, and treatment toxicity. We also performed subset analysis on 83 patients with 97 tumors treated with a volume-adapted dosing strategy in which small tumors (gross tumor volume <12 mL) received single-fraction regimens with biologically effective doses (BED) <100 Gy (total dose, 18–25 Gy) (Group 1), and larger tumors (gross tumor volume ≥12 mL) received multifraction regimens with BED ≥100 Gy (total dose, 50–60 Gy in three to four fractions) (Group 2). Results: The median follow-up time was 13.5 months. Local control for Groups 1 and 2 was 91.4% and 92.5%, respectively (p = 0.24) at 12 months. For primary lung tumors only (excluding metastases), local control was 92.6% and 91.7%, respectively (p = 0.58). Regional control, freedom from distant metastasis, and overall survival did not differ significantly between Groups 1 and 2. Rates of radiation pneumonitis, chest wall toxicity, and esophagitis were low in both groups, but all Grade 3 toxicities developed in Group 2 (p = 0.02). Conclusion: A volume-adapted dosing approach for SABR of lung tumors seems to provide excellent local control for both small- and large-volume tumors and may reduce toxicity.

  20. Stereotactic ablative radiotherapy versus lobectomy for operable stage I non-small-cell lung cancer : a pooled analysis of two randomised trials

    NARCIS (Netherlands)

    Chang, Joe Y.; Senan, Suresh; Paul, Marinus A.; Mehran, Reza J.; Louie, Alexander V.; Balter, Peter; Groen, Harry; McRae, Stephen E.; Widder, Joachim; Feng, Lei; van den Borne, Ben E. E. M.; Munsell, Mark F.; Hurkmans, Coen; Berry, Donald A.; van Werkhoven, Erik; Kresl, John J.; Dingemans, Anne-Marie; Dawood, Omar; Haasbeek, Cornelis J. A.; Carpenter, Larry S.; De Jaeger, Katrien; Komaki, Ritsuko; Slotman, Ben J.; Smit, Egbert F.; Roth, Jack A.

    Background The standard of care for operable, stage I, non-small-cell lung cancer (NSCLC) is lobectomy with mediastinal lymph node dissection or sampling. Stereotactic ablative radiotherapy (SABR) for inoperable stage I NSCLC has shown promising results, but two independent, randomised, phase 3

  1. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    International Nuclear Information System (INIS)

    Nambu, Atsushi; Tominaga, Lichto; Maehata, Yoshiyasu; Sawada, Eiichi; Araki, Tsutomu; Onishi, Hiroshi; Aoki, Shinichi; Koshiishi, Tsuyota; Kuriyama, Kengo; Komiyama, Takafumi; Marino, Kan; Araya, Masayuki; Saito, Ryo

    2011-01-01

    Chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT), appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Rib fracture was identified on follow-up CT in 41 patients (23.2%). Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months). Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%), of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present

  2. Minimizing Late Effects for Patients With Mediastinal Hodgkin Lymphoma: Deep Inspiration Breath-Hold, IMRT, or Both?

    Energy Technology Data Exchange (ETDEWEB)

    Aznar, Marianne C., E-mail: marianne.camille.aznar@regionh.dk [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Faculty of Sciences, Niels Bohr Institute, and Faculty of Health Sciences, University of Copenhagen, Copenhagen (Denmark); Maraldo, Maja V.; Schut, Deborah A. [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Lundemann, Michael [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Faculty of Sciences, Niels Bohr Institute, and Faculty of Health Sciences, University of Copenhagen, Copenhagen (Denmark); Brodin, N Patrik [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Institute of Onco-Physics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States); Vogelius, Ivan R. [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Berthelsen, Anne K. [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Specht, Lena; Petersen, Peter M. [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2015-05-01

    Purpose: Hodgkin lymphoma (HL) survivors have an increased risk of cardiovascular disease (CD), lung cancer, and breast cancer. We investigated the risk for the development of CD and secondary lung, breast, and thyroid cancer after radiation therapy (RT) delivered with deep inspiration breath-hold (DIBH) compared with free-breathing (FB) using 3-dimensional conformal RT (3DCRT) and intensity modulated RT (IMRT). The aim of this study was to determine which treatment modality best reduced the combined risk of life-threatening late effects in patients with mediastinal HL. Methods and Materials: Twenty-two patients with early-stage mediastinal HL were eligible for the study. Treatment plans were calculated with both 3DCRT and IMRT on both DIBH and FB planning computed tomographic scans. We reported the estimated dose to the heart, lung, female breasts, and thyroid and calculated the estimated life years lost attributable to CD and to lung, breast, and thyroid cancer. Results: DIBH lowered the estimated dose to heart and lung regardless of delivery technique (P<.001). There was no significant difference between IMRT-FB and 3DCRT-DIBH in mean heart dose, heart V20Gy, and lung V20Gy. The mean breast dose was increased with IMRT regardless of breathing technique. Life years lost was lowest with DIBH and highest with FB. Conclusions: In this cohort, 3DCRT-DIBH resulted in lower estimated doses and lower lifetime excess risks than did IMRT-FB. Combining IMRT and DIBH could be beneficial for a subgroup of patients.

  3. Lung Density Changes After Stereotactic Radiotherapy: A Quantitative Analysis in 50 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Palma, David A., E-mail: david.palma@uwo.ca [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Soernsen de Koste, John van; Verbakel, Wilko F.A.R. [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Vincent, Andrew [Department of Biometrics, Netherlands Cancer Institute, Amsterdam (Netherlands); Senan, Suresh [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands)

    2011-11-15

    Purpose: Radiologic lung density changes are observed in more than 50% of patients after stereotactic body radiotherapy (SBRT) for lung cancer. We studied the relationship between SBRT dose and posttreatment computed tomography (CT) density changes, a surrogate for lung injury. Methods and Materials: The SBRT fractionation schemes used to treat Stage I lung cancer with RapidArc were three fractions of 18 Gy, five fractions of 11 Gy, or eight fractions of 7.5 Gy, prescribed at the 80% isodose. Follow-up CT scans performed at less than 6 months (n = 50) and between 6 and 9 months (n = 30) after SBRT were reviewed. Posttreatment scans were coregistered with baseline scans using a B-spline deformable registration algorithm. Voxel-Hounsfield unit histograms were created for doses between 0.5 and 50 Gy. Linear mixed effects models were used to assess the effects of SBRT dose on CT density, and the influence of possible confounders was tested. Results: Increased CT density was associated with higher dose, increasing planning target volume size, and increasing time after SBRT (all p < 0.0001). Density increases were apparent in areas receiving >6 Gy, were most prominent in areas receiving >20 Gy, and seemed to plateau above 40 Gy. In regions receiving >36 Gy, the reduction in air-filled fraction of lung after treatment was up to 18%. No increase in CT density was observed in the contralateral lung receiving {>=}3 Gy. Conclusions: A dose-response relationship exists for quantitative CT density changes after SBRT. A threshold of effect is seen at low doses, and a plateau at highest doses.

  4. Planning issues for IMRT

    International Nuclear Information System (INIS)

    Hoban, P.; Schneider, M.; Smee, R.

    2001-01-01

    Full text: Despite the 'inverse planning' stage of an intensity modulated radiotherapy (IMRT) treatment there remains a large number of variables that can, and must, be set manually. These variables can significantly affect the quality of the dose distribution arrived at by the optimisation. Clinical IMRT planning with the Radionics XPlan system for micro-multileaf collimator (MMLC) delivery has allowed for important lessons to be learned regarding the best beam and organ configurations prior to optimisation of beamlet weights. Important user-definable variables are beam directions, organ parameters (dose goals/penalties), and the margin (if any) around the planning target volume (PTV) used to aid coverage. Conventional stereotactic radiotherapy (SRT) treatments typically involve non-coplanar beams since there is often an advantage in terms of cranial organ at risk (OAR) sparing. IMRT can also benefit from such a configuration. The balance between target coverage and OAR sparing is largely controlled by user-defined goal doses and penalties. Once optimisation has been performed, intensity maps can be discretised into a selected number of levels. Less levels means less field segments and thus a shorter treatment time. Although IMRT beams attempt to spare structures which are in the 'beam's eye view' (BEV) of the target volume, sparing is greater if beams which minimise the involvement of OARs in their view are used. It has been found that the use of a margin is an effective way to ensure adequate PTV coverage. Alternatively the PTV penalties can be made larger. The best result is often obtained by the use of a 3-4 mm margin, whose penalty for underdosage is somewhat less than that for the PTV. Discretising the intensity maps to 4 or 5 levels is typically a good balance between shortening treatment time and not overly degrading the dose distribution. Beam configuration is still an important step in IMRT planning, even though optimisation of intensity maps is

  5. Converging stereotactic radiotherapy using kilovoltage X-rays: experimental irradiation of normal rabbit lung and dose-volume analysis with Monte Carlo simulation.

    Science.gov (United States)

    Kawase, Takatsugu; Kunieda, Etsuo; Deloar, Hossain M; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-10-01

    To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  6. Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose-Volume Analysis With Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Kawase, Takatsugu; Kunieda, Etsuo; Deloar, Hossain M.; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N.; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-01-01

    Purpose: To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. Methods and Materials: A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. Results: A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. Conclusions: A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  7. Pulmonary Function Testing After Stereotactic Body Radiotherapy to the Lung

    International Nuclear Information System (INIS)

    Bishawi, Muath; Kim, Bong; Moore, William H.; Bilfinger, Thomas V.

    2012-01-01

    Purpose: Surgical resection remains the standard of care for operable early-stage non–small-cell lung cancer (NSCLC). However, some patients are not fit for surgery because of comorbidites such as chronic obstructive pulmonary disease (COPD) and other medical conditions. We aimed to evaluate pulmonary function and tumor volume before and after stereotactic body radiotherapy (SBRT) for patients with and without COPD in early-stage lung cancer. Methods and Materials: A review of prospectively collected data of Stage I and II lung cancers, all treated with SBRT, was performed. The total SBRT treatment was 60 Gy administered in three 20 Gy fractions. The patients were analyzed based on their COPD status, using their pretreatment pulmonary function test cutoffs as established by the American Thoracic Society guidelines (forced expiratory volume [FEV]% ≤50% predicted, FEV%/forced vital capacity [FVC]% ≤70%). Changes in tumor volume were also assessed by computed tomography. Results: Of a total of 30 patients with Stage I and II lung cancer, there were 7 patients in the COPD group (4 men, 3 women), and 23 in t he No-COPD group (9 men, 14 women). At a mean follow-up time of 4 months, for the COPD and No-COPD patients, pretreatment and posttreatment FEV% was similar: 39 ± 5 vs. 40 ± 9 (p = 0.4) and 77 ± 0.5 vs. 73 ± 24 (p = 0.9), respectively. The diffusing capacity of the lungs for carbon monoxide (DL CO ) did significantly increase for the No-COPD group after SBRT treatment: 60 ± 24 vs. 69 ± 22 (p = 0.022); however, DL CO was unchanged for the COPD group: 49 ± 13 vs. 50 ± 14 (p = 0.8). Although pretreatment tumor volume was comparable for both groups, tumor volume significantly shrank in the No-COPD group from 19 ± 24 to 9 ± 16 (p 1 and FVC, but it shrank tumor volume and improved DL CO for patients without COPD.

  8. Stereotactic body radiotherapy for lung cancer: how much does it really cost?

    Science.gov (United States)

    Lievens, Yolande; Obyn, Caroline; Mertens, Anne-Sophie; Van Halewyck, Dries; Hulstaert, Frank

    2015-03-01

    Despite the lack of randomized evidence, stereotactic body radiotherapy (SBRT) is being accepted as superior to conventional radiotherapy for patients with T1-2N0 non-small-cell lung cancer in the periphery of the lung and unfit or unwilling to undergo surgery. To introduce SBRT in a system of coverage with evidence development, a correct financing had to be determined. A time-driven activity-based costing model for radiotherapy was developed. Resource cost calculation of all radiotherapy treatments, standard and innovative, was conducted in 10 Belgian radiotherapy centers in the second half of 2012. The average cost of lung SBRT across the 10 centers (6221&OV0556;) is in the range of the average costs of standard fractionated 3D-conformal radiotherapy (5919&OV0556;) and intensity-modulated radiotherapy (7379&OV0556;) for lung cancer. Hypofractionated 3D-conformal radiotherapy and intensity-modulated radiotherapy schemes are less costly (3993&OV0556; respectively 4730&OV0556;). The SBRT cost increases with the number of fractions and is highly dependent of personnel and equipment use. SBRT cost varies more by centre than conventional radiotherapy cost, reflecting different technologies, stages in the learning curve and a lack of clear guidance in this field. Time-driven activity-based costing of radiotherapy is feasible in a multicentre setup, resulting in real-life resource costs that can form the basis for correct reimbursement schemes, supporting an early yet controlled introduction of innovative radiotherapy techniques in clinical practice.

  9. Computed Tomography Assessment of Ablation Zone Enhancement in Patients With Early-Stage Lung Cancer After Stereotactic Ablative Radiotherapy.

    Science.gov (United States)

    Moore, William; Chaya, Yair; Chaudhry, Ammar; Depasquale, Britney; Glass, Samantha; Lee, Susan; Shin, James; Mikhail, George; Bhattacharji, Priya; Kim, Bong; Bilfinger, Thomas

    2015-01-01

    Stereotactic ablative radiotherapy (SABR) offers a curative treatment for lung cancer in patients who are marginal surgical candidates. However, unlike traditional surgery the lung cancer remains in place after treatment. Thus, imaging follow-up for evaluation of recurrence is of paramount importance. In this retrospective designed Institutional Review Board-approved study, follow-up contrast-enhanced computed tomography (CT) exams were performed on sixty one patients to evaluate enhancement pattern in the ablation zone at 1, 3, 6, and 12 months after SABR. Eleven patients had recurrence within the ablation zone after SABR. The postcontrast enhancement in the recurrence group showed a washin and washout phenomenon, whereas the radiation-induced lung injury group showed continuous enhancement suggesting an inflammatory process. The textural feature of the ablation zone of enhancement and perfusion as demonstrated in computed tomography nodule enhancement may allow early differentiation of recurrence from radiation-induced lung injury in patients' status after SABR or primary lung cancer.

  10. Evaluation of intrafraction patient movement for CNS and head and neck IMRT

    International Nuclear Information System (INIS)

    Kim, Siyong; Akpati, Hilary C.; Kielbasa, Jerrold E.; Li, Jonathan G.; Liu, Chihray; Amdur, Robert J.; Palta, Jatinder R.

    2004-01-01

    Intrafraction patient motion is much more likely in intensity-modulated radiation therapy (IMRT) than in conventional radiotherapy primarily due to longer beam delivery times in IMRT treatment. In this study, we evaluated the uncertainty of intrafraction patient displacement in CNS and head and neck IMRT patients. Immobilization is performed in three steps: (1) the patient is immobilized with thermoplastic facemask, (2) the patient displacement is monitored using a commercial stereotactic infrared IR camera (ExacTrac, BrainLab) during treatment, and (3) repositioning is carried out as needed. The displacement data were recorded during beam-on time for the entire treatment duration for 5 patients using the camera system. We used the concept of cumulative time versus patient position uncertainty, referred to as an uncertainty time histogram (UTH), to analyze the data. UTH is a plot of the accumulated time during which a patient stays within the corresponding movement uncertainty. The University of Florida immobilization procedure showed an effective immobilization capability for CNS and head and neck IMRT patients by keeping the patient displacement less than 1.5 mm for 95% of treatment time (1.43 mm for 1, and 1.02 mm for 1, and less than 1.0 mm for 3 patients). The maximum displacement was 2.0 mm

  11. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    Directory of Open Access Journals (Sweden)

    Saito Ryo

    2011-10-01

    Full Text Available Abstract Background Chest wall injury after stereotactic radiotherapy (SRT for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT, appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT for primary lung cancer Materials and methods A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Results Rib fracture was identified on follow-up CT in 41 patients (23.2%. Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months. Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%, of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Conclusion Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present.

  12. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    Science.gov (United States)

    2011-01-01

    Background Chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT), appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer Materials and methods A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Results Rib fracture was identified on follow-up CT in 41 patients (23.2%). Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months). Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%), of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Conclusion Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present. PMID:21995807

  13. Effect of stereotactic dosimetric end points on overall survival for Stage I non–small cell lung cancer: A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Mulryan, Kathryn; Leech, Michelle; Forde, Elizabeth, E-mail: eforde@tcd.ie

    2015-01-01

    Stereotactic body radiation therapy (SBRT) delivers a high biologically effective dose while minimizing toxicities to surrounding tissues. Within the scope of clinical trials and local practice, there are inconsistencies in dosimetrics used to evaluate plan quality. The purpose of this critical review was to determine if dosimetric parameters used in SBRT plans have an effect on local control (LC), overall survival (OS), and toxicities. A database of relevant trials investigating SBRT for patients with early-stage non–small cell lung cancer was compiled, and a table of dosimetric variables used was created. These parameters were compared and contrasted for LC, OS, and toxicities. Dosimetric end points appear to have no effect on OS or LC. Incidences of rib fractures correlate with a lack of dose-volume constraints (DVCs) reported. This review highlights the great disparity present in clinical trials reporting dosimetrics, DVCs, and toxicities for lung SBRT. Further evidence is required before standard DVCs guidelines can be introduced. Dosimetric end points specific to stereotactic treatment planning have been proposed but require further investigation before clinical implementation.

  14. Dosimetric effect of intrafraction tumor motion in phase gated lung stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Zhao Bo; Yang Yong; Li Tianfang; Li Xiang; Heron, Dwight E.; Huq, M. Saiful

    2012-01-01

    Purpose: A major concern for lung intensity modulated radiation therapy delivery is the deviation of actually delivered dose distribution from the planned one due to simultaneous movements of multileaf collimator (MLC) leaves and tumor. For gated lung stereotactic body radiotherapy treatment (SBRT), the situation becomes even more complicated because of SBRT's characteristics such as fewer fractions, smaller target volume, higher dose rate, and extended fractional treatment time. The purpose of this work is to investigate the dosimetric effect of intrafraction tumor motion during gated lung SBRT delivery by reconstructing the delivered dose distribution with real-time tumor motion considered. Methods: The tumor motion data were retrieved from six lung patients. Each of them received three fractions of stereotactic radiotherapy treatments with Cyberknife Synchrony (Accuray, Sunnyvale, CA). Phase gating through an external surrogate was simulated with a gating window of 5 mm. The resulting residual tumor motion curves during gating (beam-on) were retrieved. Planning target volume (PTV) was defined as physician-contoured clinical target volume (CTV) surrounded by an isotropic 5 mm margin. Each patient was prescribed with 60 Gy/3 fractions. The authors developed an algorithm to reconstruct the delivered dose with tumor motion. The DMLC segments, mainly leaf position and segment weighting factor, were recalculated according to the probability density function of tumor motion curve. The new DMLC sequence file was imported back to treatment planning system to reconstruct the dose distribution. Results: Half of the patients in the study group experienced PTV D95% deviation up to 26% for fractional dose and 14% for total dose. CTV mean dose dropped by 1% with tumor motion. Although CTV is almost covered by prescribed dose with 5 mm margin, qualitative comparison on the dose distributions reveals that CTV is on the verge of underdose. The discrepancy happens due to tumor

  15. An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors

    International Nuclear Information System (INIS)

    Wu Jianzhou; Li Huiling; Shekhar, Raj; Suntharalingam, Mohan; D'Souza, Warren

    2008-01-01

    Purpose: To evaluate four planning techniques for stereotactic body radiation therapy (SBRT) in lung tumors. Methods and materials: Four SBRT plans were performed for 12 patients with stage I/II non-small-cell lung cancer under the following conditions: (1) conventional margins on free-breathing CT (plan 1), (2) generation of an internal target volume (ITV) using 4DCT with beam delivery under free-breathing conditions (plan 2), (3) gating at end-exhale (plan 3), and (4) gating at end-inhale (plan 4). Planning was performed following the RTOG 0236 protocol with a prescription dose of 54 Gy (3 fractions). For each plan 4D dose was calculated using deformable-image registration. Results: There was no significant difference in tumor dose delivered by the 4 plans. However, compared with plan 1, plans 2-4 reduced total lung BED by 1.9 ± 1.2, 3.1 ± 1.6 and 3.5 ± 2.1 Gy, reduced mean lung dose by 0.8 ± 0.5, 1.5 ± 0.8, and 1.6 ± 1.0 Gy, reduced V20 by 1.5 ± 1.0%, 2.7 ± 1.4%, and 2.8 ± 1.8%, respectively, with p < 0.01. Compared with plan 2, plans 3-4 reduced lung BED by 1.2 ± 1.0 and 1.6 ± 1.5 Gy, reduced mean lung dose by 0.6 ± 0.5 and 0.8 ± 0.7 Gy, reduced V20 by 1.2 ± 1.1% and 1.3 ± 1.5%, respectively, with p < 0.01. The differences in lung BED, mean dose and V20 of plan 4 compared with plan 3 were insignificant. Conclusions: Tumor dose coverage was statistically insignificant between all plans. However, compared with plan 1, plans 2-4 significantly reduced lung doses. Compared with plan 2, plan 3-4 also reduced lung toxicity. The difference in lung doses between plan 3 and plan 4 was not significant

  16. Compton scatter imaging: A promising modality for image guidance in lung stereotactic body radiation therapy.

    Science.gov (United States)

    Redler, Gage; Jones, Kevin C; Templeton, Alistair; Bernard, Damian; Turian, Julius; Chu, James C H

    2018-03-01

    Lung stereotactic body radiation therapy (SBRT) requires delivering large radiation doses with millimeter accuracy, making image guidance essential. An approach to forming images of patient anatomy from Compton-scattered photons during lung SBRT is presented. To investigate the potential of scatter imaging, a pinhole collimator and flat-panel detector are used for spatial localization and detection of photons scattered during external beam therapy using lung SBRT treatment conditions (6 MV FFF beam). MCNP Monte Carlo software is used to develop a model to simulate scatter images. This model is validated by comparing experimental and simulated phantom images. Patient scatter images are then simulated from 4DCT data. Experimental lung tumor phantom images have sufficient contrast-to-noise to visualize the tumor with as few as 10 MU (0.5 s temporal resolution). The relative signal intensity from objects of different composition as well as lung tumor contrast for simulated phantom images agree quantitatively with experimental images, thus validating the Monte Carlo model. Scatter images are shown to display high contrast between different materials (lung, water, bone). Simulated patient images show superior (~double) tumor contrast compared to MV transmission images. Compton scatter imaging is a promising modality for directly imaging patient anatomy during treatment without additional radiation, and it has the potential to complement existing technologies and aid tumor tracking and lung SBRT image guidance. © 2018 American Association of Physicists in Medicine.

  17. SU-E-T-542: Comparison of Stereotactic Radiosurgery (SRS) of Brain Lesions Using Gamma Knife, VMAT, IMRT, and Conformal Arcs

    International Nuclear Information System (INIS)

    Li, S; Charpentier, P; Chan, P; Neicu, T; Miyamoto, C

    2014-01-01

    Purpose: To compare dose distributions in stereotactic radiation surgery of brain lesions using gamma Knife, VMAT, conformal arcs, and IMRT in order to provide an optimal treatment. Methods: Dose distributions from single shot of 4C model of Gamma Knife at the helmet collimation sizes of 4, 8, 14, and 18 mm in diameter were compared with full arcs with the square shapes of 4×4 (or 5×5), 8×8 (or 10×10), and spherical shapes of 16 or 20 mm in diameter using EDR3 films in the same gamma knife QA phantom. Plans for ten SRS cases with single and multiple lesions were created in gamma knife plans and Pinnacle plans. The external beam plans had enlarged field size by 2-mm and used single conformal full circle arc for solitary lesion and none coplanar arcs/beams for multiple lesions. Coverage, conformity index, dose to critical organs, and integral dose to the brain and nearby critical structures were compared on all plans. Structures and dose matrices were registered in a Velocity deformable image registration system. Results: Single full circle arc from Elekta beam-modulate MLC (4-mm leaf thickness) and agility MLC (5-mm leaf thickness) have larger penumbra and less flatness than that of Gamma Knife single shot. None-coplanar arcs or beams were required to achieve similar dose distribution. In general, Gamma Knife plans provided significant less integral dose than that of linac-based plans. Benefits of IMRT and VMAT versus gamma Knife and conformal arcs were not significant. Conclusion: Our dose measurement and treatment planning evaluation clearly demonstrated dose distribution differences amount current popular SRS modalities for small solitary and multiple brain lesions. The trend of using MLC shape beams or arcs to replace conventional cones should be revisited in order to keep lower integral dose if the late correlates with some radiation-induced side effects. Pilot grant from Elekta LLC

  18. Comparison of dose distribution between 3DCRT and IMRT in middle thoracic and under thoracic esophageal carcinoma

    International Nuclear Information System (INIS)

    Li Dingjie; Liu Hailong; Mao Ronghu; Liu Ru; Guo Xiaoqi; Lei Hongchang; Wang Jianhua

    2011-01-01

    Objective: To compare the dose distribution between three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) in treating esophageal carcinoma (middle thoracic section and under thoracic section) and to select reasonable treatment methods for esophagus cancer. Methods: Ten cases with cancer of the middle thoracic section and under thoracic section esophagus were chosen for a retrospective treatment-planning study. 3DCRT and IMRT plans were created for each patient: Some critical indicators were evolved in evaluating the treatment plans of IMRT (5B and 7B) and 3DCRT (3B), such as, PTV coverage and dose-volumes to irradiated normal structures. Evaluation indicators: prescription of 50 Gy. total lung volume (V5, V10, V20), mean lung dose (MLD), spinal cord (Dmax), heart (V40) and conformality index (CI). Each plan was evaluated with respect to dose distribution,dose-volume histograms (DVHs), and additional dosimetric endpoints described below. Results: There is no significance of CRT and IMRT technique in protection of total lung volume,mean lung dose, spinal cord (Dmax), target, CI and heart. Conclusion: As To radiotherapy of esophagus cancer of the middle thoracic section and under thoracic section, IMRT has no advantage compared with 3DCRT, the selection of plan should be adapted to the situations of every patient. (authors)

  19. Stereotactic body radiotherapy (SBRT) for oligometastatic lung tumors from colorectal cancer and other primary cancers in comparison with primary lung cancer

    International Nuclear Information System (INIS)

    Takeda, Atsuya; Kunieda, Etsuo; Ohashi, Toshio; Aoki, Yousuke; Koike, Naoyoshi; Takeda, Toshiaki

    2011-01-01

    Purpose: To analyze local control of oligometastatic lung tumors (OLTs) compared with that of primary lung cancer after stereotactic body radiotherapy (SBRT). Materials and methods: Retrospective record review of patients with OLTs who received SBRT with 50 Gy in 5 fractions. Local control rates (LCRs), toxicities, and factors of prognostic significance were assessed. Results: Twenty-one colorectal OLTs, 23 OLTs from other origins, and 188 primary lung cancers were included. Multivariate analysis revealed only tumor origin was prognostically significant (p < 0.05). The 1-year/2-year LCRs in colorectal OLTs and OLTs from other origins were 80%/72% and 94%/94%, respectively. The LCR in colorectal OLTs was significantly worse than that in OLTs from the other origins and primary lung cancers with pathological and clinical diagnosis (p < 0.05, p < 0.0001 and p < 0.005). Among 44 OLT patients, Grades 2 and 3 radiation pneumonitis were identified in 2 and 1 patients, respectively. No other toxicities of more than Grade 3 occurred. Conclusion: SBRT for OLTs is tolerable. The LCR for OLTs from origins other than colorectal cancer is excellent. However, LCR for colorectal OLTs is worse than that from other origins. Therefore dose escalation should be considered to achieve good local control for colorectal OLTs.

  20. Residual F-18-FDG-PET Uptake 12 Weeks After Stereotactic Ablative Radiotherapy for Stage I Non-Small-Cell Lung Cancer Predicts Local Control

    NARCIS (Netherlands)

    Bollineni, Vikram Rao; Widder, Joachim; Pruim, Jan; Langendijk, Johannes A.; Wiegman, Erwin M.

    2012-01-01

    Purpose: To investigate the prognostic value of [F-18]fluorodeoxyglucose positron emission tomography (FDG-PET) uptake at 12 weeks after stereotactic ablative radiotherapy (SABR) for stage I non-small-cell lung cancer (NSCLC). Methods and Materials: From November 2006 to February 2010, 132 medically

  1. Outcome of four-dimensional stereotactic radiotherapy for centrally located lung tumors

    International Nuclear Information System (INIS)

    Nuyttens, Joost J.; Voort van Zyp, Noelle C. van der; Praag, John; Aluwini, Shafak; Klaveren, Rob J. van; Verhoef, Cornelis; Pattynama, Peter M.; Hoogeman, Mischa S.

    2012-01-01

    Purpose: To assess local control, overall survival, and toxicity of four-dimensional, risk-adapted stereotactic body radiotherapy (SBRT) delivered while tracking respiratory motion in patients with primary and metastatic lung cancer located in the central chest. Methods: Fifty-eight central lesions of 56 patients (39 with primary, 17 with metastatic tumors) were treated. Fifteen tumors located near the esophagus were treated with 6 fractions of 8 Gy. Other tumors were treated according to the following dose escalation scheme: 5 fractions of 9 Gy (n = 6), then 5 fractions of 10 Gy (n = 15), and finally 5 fractions of 12 Gy (n = 22). Results: Dose constraints for critical structures were generally achieved; in 21 patients the coverage of the PTV was reduced below 95% to protect adjacent organs at risk. At a median follow-up of 23 months, the actuarial 2-years local tumor control was 85% for tumors treated with a BED >100 Gy compared to 60% for tumors treated with a BED ⩽100 Gy. No grade 4 or 5 toxicity was observed. Acute grade 1–2 esophagitis was observed in 11% of patients. Conclusion: SBRT of central lung lesions can be safely delivered, with promising early tumor control in patients many of whom have severe comorbid conditions.

  2. Safety and Efficacy of Intensity-Modulated Stereotactic Body Radiotherapy Using Helical Tomotherapy for Lung Cancer and Lung Metastasis

    Directory of Open Access Journals (Sweden)

    Aiko Nagai

    2014-01-01

    Full Text Available Stereotactic body radiotherapy (SBRT proved to be an effective treatment with acceptable toxicity for lung tumors. However, the use of helical intensity-modulated (IM SBRT is controversial. We investigated the outcome of lung tumor patients treated by IMSBRT using helical tomotherapy with a Japanese standard fractionation schedule of 48 Gy in 4 fractions (n=37 or modified protocols of 50–60 Gy in 5–8 fractions (n=35. Median patient’s age was 76 years and median follow-up period for living patients was 20 months (range, 6–46. The median PTV was 6.9 cc in the 4-fraction group and 14 cc in the 5- to 8-fraction group (P=0.001. Grade 2 radiation pneumonitis was seen in 2 of 37 patients in the 4-fraction group and in 2 of 35 patients in the 5- to 8-fraction group (log-rank P=0.92. Other major complications were not observed. The LC rates at 2 years were 87% in the 4-fraction group and 83% in the 5- to 8-fraction group. Helical IMSBRT for lung tumors is safe and effective. Patients with a high risk of developing severe complications may also be safely treated using 5–8 fractions. The results of the current study warrant further studies of helical IMSBRT.

  3. Radiosensitivity of Colon and Rectal Lung Oligometastasis Treated With Stereotactic Ablative Radiotherapy.

    Science.gov (United States)

    Kinj, Rémy; Bondiau, Pierre-Yves; François, Eric; Gérard, Jean-Pierre; Naghavi, Arash O; Leysalle, Axel; Chamorey, Emmanuel; Evesque, Ludovic; Padovani, Bernard; Ianessi, Antoine; Benezery, Karen; Doyen, Jérôme

    2017-09-01

    Patients with metastatic colorectal cancer (CRC) may present with oligometastatic lung lesions for which stereotactic ablative radiotherapy (SABR) can be utilized. This study aims to report efficacy and prognostic factors associated with colorectal lung metastases treated with SABR. This is a retrospective study including patients who presented with lung oligometastasis from CRC treated with SABR from September 2007 to November 2014. We identified 53 oligometastatic patients with 87 lung lesions. The median prescription dose was 60 Gy in 3 fractions (median biological effective dose of 180 Gy). The median follow up was 33 months. The 1- and 2-year local control, metastasis-free survival, and overall survival were 79.8% and 78.2%, 29.2% and 16.2%, and 83.8% and 69.3%, respectively. On multivariate analysis, rectal primary site (P = .001) and > 2 metastases (P = .02) were significantly associated with a lower local control rate. Rectal lesions were associated with higher radiation dose (169.3 Gy vs. 153.3 Gy; P = .01) and higher rate of KRAS mutations (73.3% vs. 40.4%; P = .02). KRAS mutation did not predict for local control, but predicted for a 1-year metastasis-free survival detriment (0% vs. 37.5%; P = .04), when compared with KRAS wild-type. On multivariate analysis, there is an overall survival detriment associated with gross tumor volume ≥ 3266 mm 3 (P = .03) and > 2 metastases (P = .04). In CRC, oligometastatic lung lesions treated with SABR had a worse outcome in patients presenting with a rectal primary, > 2 metastases, or treated with a larger gross tumor volume. More aggressive treatment may be considered in this subset of patients to improve outcome. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. The variability of tumor motion and respiration pattern in Stereotactic Body RadioTherapy(SBRT) for Lung cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Joon; Bae, Sun Myeong; Baek, Geum Mun; Kang, Tae Young; Seo, Dong Rin [Dept. of Radiation Oncology, ASAN Medical Center, Seoul (Korea, Republic of)

    2016-06-15

    The purpose of this study is to evaluate the variability of tumor motion and respiration pattern in lung cancer patients undergoing Stereotactic Body RadioTherapy(SBRT) by using On-Board imager (OBI) system and Real-time Position Management (RPM) System. This study population consisted of 60 lung cancer patient treated with stereotactic body radiotherapy (48 Gy / 4 fractions). Of these, 30 were treated with gating (group 1) and 30 without gating(group2): typically the patients whose tumors showed three-dimensional respiratory motion > 10 mm were selected for gating. 4-dimensional Computed Tomography (4DCT). Cone Beam CT (CBCT) and Fluoroscopy images were used to measure the tumor motion. RPM system was used to evaluate the variability of respiration pattern on SBRT for group1. The mean difference of tumor motion among 4DCT, CBCT and Fluoroscopy images in the cranio-caudal direction was 2.3 mm in group 1, 2. The maximum difference was 12.5 mm in the group 1 and 8.5 mm in group 2. The number of treatment fractions that patient's respiration pattern was within Upper-Lower threshold on SBRT in group 2 was 31 fractions. A patient who exhibited the most unstable pattern exceeded 108 times in a fraction. Although many patients in group 1 and 2 kept the reproducibility of tumor motion within 5 mm during their treatment, some patients exhibited variability of tumor motion in the CBCT and Fluoroscopy images. It was possible to improve the accuracy of dose delivery in SBRT without gating for lung cancer patient by using RPM system.

  5. Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study

    International Nuclear Information System (INIS)

    Hurkmans, Coen W; Cuijpers, Johan P; Lagerwaard, Frank J; Widder, Joachim; Heide, Uulke A van der; Schuring, Danny; Senan, Suresh

    2009-01-01

    A phase III multi-centre randomised trial (ROSEL) has been initiated to establish the role of stereotactic radiotherapy in patients with operable stage IA lung cancer. Due to rapid changes in radiotherapy technology and evolving techniques for image-guided delivery, guidelines had to be developed in order to ensure uniformity in implementation of stereotactic radiotherapy in this multi-centre study. A Quality Assurance Working Party was formed by radiation oncologists and clinical physicists from both academic as well as non-academic hospitals that had already implemented stereotactic radiotherapy for lung cancer. A literature survey was conducted and consensus meetings were held in which both the knowledge from the literature and clinical experience were pooled. In addition, a planning study was performed in 26 stage I patients, of which 22 were stage 1A, in order to develop and evaluate the planning guidelines. Plans were optimised according to parameters adopted from RTOG trials using both an algorithm with a simple homogeneity correction (Type A) and a more advanced algorithm (Type B). Dose conformity requirements were then formulated based on these results. Based on current literature and expert experience, guidelines were formulated for this phase III study of stereotactic radiotherapy versus surgery. These guidelines can serve to facilitate the design of future multi-centre clinical trials of stereotactic radiotherapy in other patient groups and aid a more uniform implementation of this technique outside clinical trials

  6. Pulmonary Function Testing After Stereotactic Body Radiotherapy to the Lung

    Energy Technology Data Exchange (ETDEWEB)

    Bishawi, Muath [Division of Cardiothoracic Surgery, Stony Brook University Medical Center, Stony Brook, NY (United States); Kim, Bong [Division of Radiology, Stony Brook University Medical Center, Stony Brook, NY (United States); Moore, William H. [Division of Radiation Oncology, Stony Brook University, Stony Brook, NY (United States); Bilfinger, Thomas V., E-mail: Thomas.bilfinger@stonybrook.edu [Division of Cardiothoracic Surgery, Stony Brook University Medical Center, Stony Brook, NY (United States)

    2012-01-01

    Purpose: Surgical resection remains the standard of care for operable early-stage non-small-cell lung cancer (NSCLC). However, some patients are not fit for surgery because of comorbidites such as chronic obstructive pulmonary disease (COPD) and other medical conditions. We aimed to evaluate pulmonary function and tumor volume before and after stereotactic body radiotherapy (SBRT) for patients with and without COPD in early-stage lung cancer. Methods and Materials: A review of prospectively collected data of Stage I and II lung cancers, all treated with SBRT, was performed. The total SBRT treatment was 60 Gy administered in three 20 Gy fractions. The patients were analyzed based on their COPD status, using their pretreatment pulmonary function test cutoffs as established by the American Thoracic Society guidelines (forced expiratory volume [FEV]% {<=}50% predicted, FEV%/forced vital capacity [FVC]% {<=}70%). Changes in tumor volume were also assessed by computed tomography. Results: Of a total of 30 patients with Stage I and II lung cancer, there were 7 patients in the COPD group (4 men, 3 women), and 23 in t he No-COPD group (9 men, 14 women). At a mean follow-up time of 4 months, for the COPD and No-COPD patients, pretreatment and posttreatment FEV% was similar: 39 {+-} 5 vs. 40 {+-} 9 (p = 0.4) and 77 {+-} 0.5 vs. 73 {+-} 24 (p = 0.9), respectively. The diffusing capacity of the lungs for carbon monoxide (DL{sub CO}) did significantly increase for the No-COPD group after SBRT treatment: 60 {+-} 24 vs. 69 {+-} 22 (p = 0.022); however, DL{sub CO} was unchanged for the COPD group: 49 {+-} 13 vs. 50 {+-} 14 (p = 0.8). Although pretreatment tumor volume was comparable for both groups, tumor volume significantly shrank in the No-COPD group from 19 {+-} 24 to 9 {+-} 16 (p < 0.001), and there was a trend in the COPD patients from 12 {+-} 9 to 6 {+-} 5 (p = 0.06). Conclusion: SBRT did not seem to have an effect on FEV{sub 1} and FVC, but it shrank tumor volume and

  7. SU-E-T-500: Initial Implementation of GPU-Based Particle Swarm Optimization for 4D IMRT Planning in Lung SBRT

    International Nuclear Information System (INIS)

    Modiri, A; Hagan, A; Gu, X; Sawant, A

    2015-01-01

    Purpose 4D-IMRT planning, combined with dynamic MLC tracking delivery, utilizes the temporal dimension as an additional degree of freedom to achieve improved OAR-sparing. The computational complexity for such optimization increases exponentially with increase in dimensionality. In order to accomplish this task in a clinically-feasible time frame, we present an initial implementation of GPU-based 4D-IMRT planning based on particle swarm optimization (PSO). Methods The target and normal structures were manually contoured on ten phases of a 4DCT scan of a NSCLC patient with a 54cm3 right-lower-lobe tumor (1.5cm motion). Corresponding ten 3D-IMRT plans were created in the Eclipse treatment planning system (Ver-13.6). A vendor-provided scripting interface was used to export 3D-dose matrices corresponding to each control point (10 phases × 9 beams × 166 control points = 14,940), which served as input to PSO. The optimization task was to iteratively adjust the weights of each control point and scale the corresponding dose matrices. In order to handle the large amount of data in GPU memory, dose matrices were sparsified and placed in contiguous memory blocks with the 14,940 weight-variables. PSO was implemented on CPU (dual-Xeon, 3.1GHz) and GPU (dual-K20 Tesla, 2496 cores, 3.52Tflops, each) platforms. NiftyReg, an open-source deformable image registration package, was used to calculate the summed dose. Results The 4D-PSO plan yielded PTV coverage comparable to the clinical ITV-based plan and significantly higher OAR-sparing, as follows: lung Dmean=33%; lung V20=27%; spinal cord Dmax=26%; esophagus Dmax=42%; heart Dmax=0%; heart Dmean=47%. The GPU-PSO processing time for 14940 variables and 7 PSO-particles was 41% that of CPU-PSO (199 vs. 488 minutes). Conclusion Truly 4D-IMRT planning can yield significant OAR dose-sparing while preserving PTV coverage. The corresponding optimization problem is large-scale, non-convex and computationally rigorous. Our initial results

  8. SU-E-T-500: Initial Implementation of GPU-Based Particle Swarm Optimization for 4D IMRT Planning in Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Modiri, A; Hagan, A; Gu, X; Sawant, A [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose 4D-IMRT planning, combined with dynamic MLC tracking delivery, utilizes the temporal dimension as an additional degree of freedom to achieve improved OAR-sparing. The computational complexity for such optimization increases exponentially with increase in dimensionality. In order to accomplish this task in a clinically-feasible time frame, we present an initial implementation of GPU-based 4D-IMRT planning based on particle swarm optimization (PSO). Methods The target and normal structures were manually contoured on ten phases of a 4DCT scan of a NSCLC patient with a 54cm3 right-lower-lobe tumor (1.5cm motion). Corresponding ten 3D-IMRT plans were created in the Eclipse treatment planning system (Ver-13.6). A vendor-provided scripting interface was used to export 3D-dose matrices corresponding to each control point (10 phases × 9 beams × 166 control points = 14,940), which served as input to PSO. The optimization task was to iteratively adjust the weights of each control point and scale the corresponding dose matrices. In order to handle the large amount of data in GPU memory, dose matrices were sparsified and placed in contiguous memory blocks with the 14,940 weight-variables. PSO was implemented on CPU (dual-Xeon, 3.1GHz) and GPU (dual-K20 Tesla, 2496 cores, 3.52Tflops, each) platforms. NiftyReg, an open-source deformable image registration package, was used to calculate the summed dose. Results The 4D-PSO plan yielded PTV coverage comparable to the clinical ITV-based plan and significantly higher OAR-sparing, as follows: lung Dmean=33%; lung V20=27%; spinal cord Dmax=26%; esophagus Dmax=42%; heart Dmax=0%; heart Dmean=47%. The GPU-PSO processing time for 14940 variables and 7 PSO-particles was 41% that of CPU-PSO (199 vs. 488 minutes). Conclusion Truly 4D-IMRT planning can yield significant OAR dose-sparing while preserving PTV coverage. The corresponding optimization problem is large-scale, non-convex and computationally rigorous. Our initial results

  9. Automated selection of beam orientations and segmented intensity-modulated radiotherapy (IMRT) for treatment of oesophagus tumors

    International Nuclear Information System (INIS)

    Woudstra, Evert; Heijmen, Ben J.M.; Storchi, Pascal R.M.

    2005-01-01

    Background and purpose: For some treatment sites, there is evidence in the literature that five to nine equiangular input beam directions are enough for generating IMRT plans. For oesophagus cancer, there is a report showing that going from four to nine beams may even result in lower quality plans. In this paper, our previously published algorithm for automated beam angle selection (Cycle) has been extended to include segmented IMRT. For oesophagus cancer patients, we have investigated whether automated orientation selection from a large number of equiangular input beam directions (up to thirty-six) for IMRT optimisation can result in improved lung sparing. Materials and methods: CT-data from five oesophagus patients treated recently in our institute were used for this study. For a prescribed mean PTV dose of 55 Gy, Cycle was used in an iterative procedure to minimise the mean lung dose under the following hard constraints: standard deviation for PTV dose inhomogeneity 2% (1,1 Gy), maximum spinal cord dose 45 Gy. Conformal radiotherapy (CFRT) and IMRT plans for a standard four field oesophagus beam configuration were compared with IMRT plans generated by automated selection from nine or thirty-six equiangular input beam orientations. Comparisons were also made with dose distributions generated with our commercial treatment planning system (TPS), and with observations in the literature. Results: Using Cycle, automated orientation selection from nine or thirty-six input beam directions resulted in improved lung sparing compared to the four field set-ups. Compared to selection from nine input orientations, selection from thirty-six directions did always result in lower mean lung doses, sometimes with even fewer non-zero weight beams. On average only seven beams with a non-zero weight were enough for obtaining the lowest mean lung dose, yielding clinically feasible plans even in case of thirty-six input directions for the optimisation process. With our commercial TPS

  10. Stereotactic body radiation therapy for early-stage non-small-cell lung cancer. The Japanese experience

    International Nuclear Information System (INIS)

    Hiraoka, Masahiro; Nagata, Yasushi

    2004-01-01

    Stereotactic body radiation therapy is a new treatment modality for early-stage non-small-cell lung cancer, and is being intensively investigated in the United States, the European Union, and Japan. We started a feasibility study of this therapy in July 1998, using a stereotactic body frame. The eligibility criteria for primary lung cancer were: solitary tumor less than 4 cm; inoperable, or the patient refused operation; histologically confirmed malignancy; no necessity for oxygen support; performance status equal to or less than 2, and the tumor was not close to the spinal cord. A total dose of 48 Gy was delivered in four fractions in 2 weeks in most patients. Lung toxicity was minimal. No grade II toxicities for spinal cord, bronchus, pulmonary artery, or esophagus were observed. Overall survival for 29 patients with stage IA, and 14 patients with stage IB disease was 87% and 80%, respectively. No local recurrence was observed in a follow-up of 3-50 months. Regional lymph node recurrence developed in 1 patient, and distant metastases developed in 4 patients. We retrospectively analyzed 241 patients from 13 Japanese institutions. The local recurrence rate was 20% when the biological equivalent dose (BED) was less than 100 Gy, and 6.5% when the BED was over 100 Gy. Overall survival at 3 years was 42% when the BED was less than 100 Gy, and 46% when it was over 100 Gy. In tumors which received a BED of more than 100 Gy, overall survival at 3 years was 91% for operable patients, and 50% for inoperable patients. Long-term results, in terms of local control, regional recurrence, survival, and complications, are not yet evaluated. However, this treatment modality is highly expected to be a standard treatment for inoperable patients, and it may be an alternative to lobectomy for operative patients. A prospective trial, which is now ongoing, will, answer these questions. (author)

  11. Stereotactic ablative radiotherapy after concomitant chemoradiotherapy in non-small cell lung cancer: A TITE-CRM phase 1 trial.

    Science.gov (United States)

    Doyen, Jérôme; Poudenx, Michel; Gal, Jocelyn; Otto, Josiane; Guerder, Caroline; Naghavi, Arash O; Gérard, Anais; Leysalle, Axel; Cohen, Charlotte; Padovani, Bernard; Ianessi, Antoine; Schiappa, Renaud; Chamorey, Emmanuel; Bondiau, Pierre-Yves

    2018-05-01

    Platinum based chemoradiotherapy is the standard of care for inoperable non-small cell lung cancer (NSCLC). With evidence that NSCLC can have a dose dependent response with stereotactic ablative radiotherapy (SABR), we hypothesize that a SABR boost on residual tumor treated with chemoradiotherapy could increase treatment efficacy. The purpose of this study was to determine feasibility of such an approach. A prospective phase I trial was performed including 26 patients. Time-to-event continual reassessment method (TITE-CRM) was used for dose escalation which ranged from 3 × 7 to 3 × 12 Gy for the stereotactic boost, after 46 Gy (2 Gy per day) of chemoradiotherapy. Median follow-up was of 37.1 months (1.7-60.7), and 3, 4, 3, 3, 9 and 4 patients were included at the dose levels 1, 2, 3, 4, 5 and 6, respectively. During chemoradiotherapy, 9 patients experienced grade 3 toxicity. After stereotactic radiotherapy, 1 patient experienced an esophageal fistula (with local relapse) at the 3 × 11 Gy level, and 1 patient died from hemoptysis at the 3 × 12 Gy level. The 2-year rate of local control, locoregional free survival, metastasis-free survival, and overall survival was 70.3%, 55.5%, 44.5% and 50.8%, respectively. In the treatment of NSCLC with chemoradiotherapy followed by a stereotactic boost, the safe recommended dose in our protocol was a boost dose of 3 × 11 Gy. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Stereotactic Body Radiation Therapy Delivery in a Genetically Engineered Mouse Model of Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Du, Shisuo; Lockamy, Virginia [Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Zhou, Lin [Department of Thoracic Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan (China); Xue, Christine; LeBlanc, Justin [Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Glenn, Shonna [Xstrahl, Inc, Suwanee, Georgia (United States); Shukla, Gaurav; Yu, Yan; Dicker, Adam P.; Leeper, Dennis B. [Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Lu, You [Department of Thoracic Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan (China); Lu, Bo, E-mail: bo.lu@jefferson.edu [Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania (United States)

    2016-11-01

    Purpose: To implement clinical stereotactic body radiation therapy (SBRT) using a small animal radiation research platform (SARRP) in a genetically engineered mouse model of lung cancer. Methods and Materials: A murine model of multinodular Kras-driven spontaneous lung tumors was used for this study. High-resolution cone beam computed tomography (CBCT) imaging was used to identify and target peripheral tumor nodules, whereas off-target lung nodules in the contralateral lung were used as a nonirradiated control. CBCT imaging helps localize tumors, facilitate high-precision irradiation, and monitor tumor growth. SBRT planning, prescription dose, and dose limits to normal tissue followed the guidelines set by RTOG protocols. Pathologic changes in the irradiated tumors were investigated using immunohistochemistry. Results: The image guided radiation delivery using the SARRP system effectively localized and treated lung cancer with precision in a genetically engineered mouse model of lung cancer. Immunohistochemical data confirmed the precise delivery of SBRT to the targeted lung nodules. The 60 Gy delivered in 3 weekly fractions markedly reduced the proliferation index, Ki-67, and increased apoptosis per staining for cleaved caspase-3 in irradiated lung nodules. Conclusions: It is feasible to use the SARRP platform to perform dosimetric planning and delivery of SBRT in mice with lung cancer. This allows for preclinical studies that provide a rationale for clinical trials involving SBRT, especially when combined with immunotherapeutics.

  13. Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer

    International Nuclear Information System (INIS)

    Yang, Yun; Catalano, Suzanne; Kelsey, Chris R.; Yoo, David S.; Yin, Fang-Fang; Cai, Jing

    2014-01-01

    To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V 100% ), max PTV dose (PTV D max ), percentage prescription dose to 0.35 cc of cord (cord D 0.35 cc ), percentage prescription dose to 0.35 cc and 5 cc of esophagus (esophagus D 0.35 cc and D 5 cc ), and volume of the lungs receiving at least 20 Gy (lung V 20 ). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were 100% , PTV D max , cord D 0.35 cc , esophagus D 0.35 cc , esophagus D 5 cc , and lung V 20 was − 8.36%, − 6.06%, 11.96%, 8.66%, 6.02%, and − 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R 2 range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5° in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets

  14. Comparison of dose evaluation index by pencil beam convolution and anisotropic analytical algorithm in stereotactic radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Tachibana, Masayuki; Noguchi, Yoshitaka; Fukunaga, Jyunichi; Hirano, Naomi; Yoshidome, Satoshi; Hirose, Takaaki

    2009-01-01

    We previously studied dose distributions of stereotactic radiotherapy (SRT) for lung cancer. Our aim is to compare in combination pencil beam convolution with the inhomogeneity correction algorithm of Batho power low [PBC (BPL)] to the anisotropic analytical algorithm (AAA) by using the dose evaluation indexes. There were significant differences in D95, planning target volume (PTV) mean dose, homogeneity index, and conformity index, V10, and V5. The dose distributions inside the PTV calculated by PBC (BPL) were more uniform than those of AAA. There were no significant differences in V20 and mean dose of total lung. There was no large difference for the whole lung. However, the surrounding high-dose region of PTV became smaller in AAA. The difference in dose evaluation indexes extended between PBC (BPL) and AAA that as many as low CT value of lung. When the dose calculation algorithm is changed, it is necessary to consider difference dose distributions compared with those of established practice. (author)

  15. Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver

    International Nuclear Information System (INIS)

    Wulf, Joern; Haedinger, Ulrich; Oppitz, Ulrich; Thiele, Wibke; Flentje, Michael

    2003-01-01

    Background and purpose: Previous analyses of target reproducibility in extracranial stereotactic radiotherapy have revealed standard security margins for planning target volume (PTV) definition of 5 mm in axial and 5-10 mm in longitudinal direction. In this study the reproducibility of the clinical target volume (CTV) of lung and liver tumors within the PTV over the complete course of hypofractionated treatment is evaluated. The impact of target mobility on dose to the CTV is assessed by dose-volume histograms (DVH). Materials and methods: Twenty-two pulmonary and 21 hepatic targets were treated with three stereotactic fractions of 10 Gy to the PTV-enclosing 100%-isodose with normalization to 150% at the isocenter. A conformal dose distribution was related to the PTV, which was defined by margins of 5-10 mm added to the CTV. Prior to each fraction a computed tomography (CT)-simulation over the complete target volume was performed resulting in a total of 60 CT-simulations for lung and 58 CT-simulations for hepatic targets. The CTV from each CT-simulation was segmented and matched with the CT-study used for treatment planning. A DVH of the simulated CTV was calculated for each fraction. The target coverage (TC) of dose to the simulated CTV was defined as the proportion of the CTV receiving at least the reference dose (100%). Results: A decrease of TC to 3 . Conclusions: Target reproducibility was precise within the reference isodose in 91% of lung and 81% of liver tumors with a TC of the complete CTV ≥95% at each fraction of treatment. Pulmonary targets with increased breathing mobility and liver tumors >100 cm 3 are at risk for target deviation exceeding the standard security margins for PTV-definition at least for one fraction and require individual evaluation of sufficient margins

  16. Impact of intensity-modulated radiation therapy as a boost treatment on the lung-dose distributions for non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Choi, Youngmin; Kim, Jeung Kee; Lee, Hyung Sik; Hur, Won Joo; Chai, Gyu Young; Kang, Ki Mun

    2005-01-01

    Purpose: To investigate the feasibility of intensity-modulated radiotherapy (IMRT) as a method of boost radiotherapy after the initial irradiation by the conventional anterior/posterior opposed beams for centrally located non-small-cell lung cancer through the evaluation of dose distributions according to the various boost methods. Methods and Materials: Seven patients with T3 or T4 lung cancer and mediastinal node enlargement who previously received radiotherapy were studied. All patients underwent virtual simulation retrospectively with the previous treatment planning computed tomograms. Initial radiotherapy plans were designed to deliver 40 Gy to the primary tumor and involved nodal regions with the conventional anterior/posterior opposed beams. Two radiation dose levels, 24 and 30 Gy, were used for the boost radiotherapy plans, and four different boost methods (a three-dimensional conformal radiotherapy [3DCRT], five-, seven-, and nine-beam IMRT) were applied to each dose level. The goals of the boost plans were to deliver the prescribed radiation dose to 95% of the planning target volume (PTV) and minimize the volumes of the normal lungs and spinal cord irradiated above their tolerance doses. Dose distributions in the PTVs and lungs, according to the four types of boost plans, were compared in the boost and sum plans, respectively. Results: The percentage of lung volumes irradiated >20 Gy (V20) was reduced significantly in the IMRT boost plans compared with the 3DCRT boost plans at the 24- and 30-Gy dose levels (p 0.007 and 0.0315 respectively). Mean lung doses according to the boost methods were not different in the 24- and 30-Gy boost plans. The conformity indexes (CI) of the IMRT boost plans were lower than those of the 3DCRT plans in the 24- and 30-Gy plans (p = 0.001 in both). For the sum plans, there was no difference of the dose distributions in the PTVs and lungs according to the boost methods. Conclusions: In the boost plans the V20s and CIs were

  17. MO-F-CAMPUS-T-04: Development and Evaluation of a Knowledge-Based Model for Treatment Planning of Lung Cancer Patients Using Stereotactic Body Radiotherapy (SBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, K; Kim, J; Reding, A; Fraser, C; Lu, S; Gordon, J; Ajlouni, M; Movsas, B; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2015-06-15

    Purpose: To describe the development of a knowledge-based treatment planning model for lung cancer patients treated with SBRT, and to evaluate the model performance and applicability to different planning techniques and tumor locations. Methods: 105 lung SBRT plans previously treated at our institution were included in the development of the model using Varian’s RapidPlan DVH estimation algorithm. The model was trained with a combination of IMRT, VMAT, and 3D–CRT techniques. Tumor locations encompassed lesions located centrally vs peripherally (43:62), upper vs lower (62:43), and anterior vs posterior lobes (60:45). The model performance was validated with 25 cases independent of the training set, for both IMRT and VMAT. Model generated plans were created with only one optimization and no planner intervention. The original, general model was also divided into four separate models according to tumor location. The model was also applied using different beam templates to further improve workflow. Dose differences to targets and organs-at-risk were evaluated. Results: IMRT and VMAT RapidPlan generated plans were comparable to clinical plans with respect to target coverage and several OARs. Spinal cord dose was lowered in the model-based plans by 1Gy compared to the clinical plans, p=0.008. Splitting the model according to tumor location resulted in insignificant differences in DVH estimation. The peripheral model decreased esophagus dose to the central lesions by 0.5Gy compared to the original model, p=0.025, and the posterior model increased dose to the spinal cord by 1Gy compared to the anterior model, p=0.001. All template beam plans met OAR criteria, with 1Gy increases noted in maximum heart dose for the 9-field plans, p=0.04. Conclusion: A RapidPlan knowledge-based model for lung SBRT produces comparable results to clinical plans, with increased consistency and greater efficiency. The model encompasses both IMRT and VMAT techniques, differing tumor locations

  18. Stereotactic body radiation therapy versus conventional radiation therapy in patients with early stage non-small cell lung cancer

    DEFF Research Database (Denmark)

    Jeppesen, Stefan Starup; Schytte, Tine; Jensen, Henrik R

    2013-01-01

    Abstract Introduction. Stereotactic body radiation therapy (SBRT) for early stage non-small cell lung cancer (NSCLC) is now an accepted and patient friendly treatment, but still controversy exists about its comparability to conventional radiation therapy (RT). The purpose of this single...... and SBRT predicted improved prognosis. However, staging procedure, confirmation procedure of recurrence and technical improvements of radiation treatment is likely to influence outcomes. However, SBRT seems to be as efficient as conventional RT and is a more convenient treatment for the patients....

  19. Comparative dosimetric analysis of IMRT and VMAT (RapidArc in brain, head and neck, breast and prostate malignancies

    Directory of Open Access Journals (Sweden)

    Mirza Athar Ali

    2015-03-01

    Full Text Available Purpose: Intensity modulated radiotherapy (IMRT in the recent past has established itself as a gold standard for organs at risk (OAR sparing, target coverage and dose conformity. With the advent of a rotational treatment technology such as volumetric modulated arc therapy (VMAT, an inter-comparison is warranted to address the advantages and disadvantages of each technique. Methods: Twenty patients were selected retrospectively from our patient database. Sites included were brain, head and neck, chest wall, and prostate, with five patients for each site. For all the selected patients, both the IMRT and VMAT treatment plans were generated. Plan comparison was done in terms of OAR dose, dose homogeneity index (HI, dose conformity index (CI, target coverage, low isodose volumes, monitor units (MUs, and treatment time.Results: The VMAT showed better sparing of “parotids minus planning target volume (PTV”, spinal cord and head of femur as compared to the IMRT. The lung V40 for VMAT was lower, whereas the lung V10, contralateral lung mean dose, contralateral breast mean dose and mean body dose were lower with IMRT for chest wall cases. Both the VMAT and IMRT achieved comparable HI except for the brain site, where IMRT scored over VMAT. The CI achieved by the IMRT and VMAT were similar except for chest wall cases, whereas the VMAT achieved better dose conformity. The target coverage was comparable with both the plans. The VMAT clearly scored over IMRT in terms of average MUs (486 versus 812 respectively and average treatment time (2.54 minutes versus 5.54 minutes per treatment session. Conclusion: The VMAT (RapidArc has a potential to generate treatment plans for various anatomical sites which are comparable with the corresponding IMRT plans in terms of OAR sparing and plan quality parameters. The VMAT significantly reduces treatment time as compared to the IMRT, thus VMAT can increase the throughput of a busy radiotherapy department.

  20. Clinical outcome of stereotactic body radiotherapy of 54 Gy in nine fractions for patients with localized lung tumor using a custom-made immobilization system

    International Nuclear Information System (INIS)

    Aoki, Masahiko; Abe, Yoshinao; Kondo, Hidehiro

    2007-01-01

    The aim of this study was to investigate the clinical outcome of stereotactic body radiotherapy (SBRT) of 54 Gy in nine fractions for patients with localized lung tumor using a custom-made immobilization system. The subjects were 19 patients who had localized lung tumor (11 primaries, 8 metastases) between May 2003 and October 2005. Treatment was conducted on 19 lung tumors by fixed multiple noncoplanar conformal beams with a standard linear accelerator. The isocentric dose was 54 Gy in nine fractions. The median overall treatment time was 15 days (range 11-22 days). All patients were immobilized by a thermo-shell and a custom-made headrest during the treatment. The crude local tumor control rate was 95% during the follow-up of 9.4-39.5 (median 17.7) months. In-field recurrence was noted in only one patient at the last follow-up. The Kaplan-Meier overall survival rate at 2 years was 89.5%. Grade 1 radiation pneumonia and grade 1 radiation fibrosis were observed in 12 of the 19 patients. Treatment-related severe early and late complications were not observed in this series. The stereotactic body radiotherapy of 54 Gy in nine fractions achieved acceptable tumor control without any severe complications. The results suggest that SBRT can be one of the alternatives for patients with localized lung tumors. (author)

  1. Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Simeonova-Chergou, Anna; Jahnke, Anika; Siebenlist, Kerstin; Stieler, Florian; Mai, Sabine; Boda-Heggemann, Judit; Wenz, Frederik; Lohr, Frank; Jahnke, Lennart [University Medical Center Mannheim, University of Heidelberg, Department of Radiotherapy and Oncology, Mannheim (Germany)

    2016-03-15

    High-dose radiotherapy of lung cancer is challenging. Tumors may move by up to 2 cm in craniocaudal and anteroposterior directions as a function of breathing cycle. Tumor displacement increases with treatment time, which consequentially increases the treatment uncertainty. This study analyzed whether automatically gated cone-beam-CT (CBCT)-controlled intensity modulated fast deep inspiration breath hold (DIBH) stereotactic body radiation therapy (SBRT) in flattening filter free (FFF) technique and normofractionated lung DIBH intensity-modulated radiotherapy (IMRT)/volumetric-modulated arc therapy (VMAT) treatments delivered with a flattening filter can be applied with sufficient accuracy within a clinically acceptable timeslot. Plans of 34 patients with lung tumors were analyzed. Of these patients, 17 received computer-controlled fast DIBH SBRT with a dose of 60 Gy (5 fractions of 12 Gy or 12 fractions of 5 Gy) in an FFF VMAT technique (FFF-SBRT) every other day and 17 received conventional VMAT with a flattening filter (conv-VMAT) and 2-Gy daily fractional doses (cumulative dose 50-70 Gy). FFF-SBRT plans required more monitor units (MU) than conv-VMAT plans (2956.6 ± 885.3 MU for 12 Gy/fraction and 1148.7 ± 289.2 MU for 5 Gy/fraction vs. 608.4 ± 157.5 MU for 2 Gy/fraction). Total treatment and net beam-on times were shorter for FFF-SBRT plans than conv-VMAT plans (268.0 ± 74.4 s vs. 330.2 ± 93.6 s and 85.8 ± 25.3 s vs. 117.2 ± 29.6 s, respectively). Total slot time was 13.0 min for FFF-SBRT and 14.0 min for conv-VMAT. All modalities could be delivered accurately despite multiple beam-on/-off cycles and were robust against multiple interruptions. Automatically gated CBCT-controlled fast DIBH SBRT in VMAT FFF technique and normofractionated lung DIBH VMAT can be applied with a low number of breath-holds in a short timeslot, with excellent dosimetric accuracy. In clinical routine, these approaches combine optimally reduced lung tissue irradiation with maximal

  2. Definition of stereotactic body radiotherapy. Principles and practice for the treatment of stage I non-small cell lung cancer

    International Nuclear Information System (INIS)

    Guckenberger, M.; Sauer, O.; Andratschke, N.; Alheit, H.; Holy, R.; Moustakis, C.; Nestle, U.

    2014-01-01

    This report from the Stereotactic Radiotherapy Working Group of the German Society of Radiation Oncology (Deutschen Gesellschaft fuer Radioonkologie, DEGRO) provides a definition of stereotactic body radiotherapy (SBRT) that agrees with that of other international societies. SBRT is defined as a method of external beam radiotherapy (EBRT) that accurately delivers a high irradiation dose to an extracranial target in one or few treatment fractions. Detailed recommendations concerning the principles and practice of SBRT for early stage non-small cell lung cancer (NSCLC) are given. These cover the entire treatment process; from patient selection, staging, treatment planning and delivery to follow-up. SBRT was identified as the method of choice when compared to best supportive care (BSC), conventionally fractionated radiotherapy and radiofrequency ablation. Based on current evidence, SBRT appears to be on a par with sublobar resection and is an effective treatment option in operable patients who refuse lobectomy. (orig.) [de

  3. The impact of technology on the changing practice of lung SBRT

    NARCIS (Netherlands)

    M.C. Aznar (Marianne C.); Warren, S. (Samantha); M.S. Hoogeman (Mischa); M. Josipovic (Mirjana)

    2018-01-01

    textabstractStereotactic body radiotherapy (SBRT) for lung tumours has been gaining wide acceptance in lung cancer. Here, we review the technological evolution of SBRT delivery in lung cancer, from the first treatments using the stereotactic body frame in the 1990's to modern developments in image

  4. Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yun; Catalano, Suzanne; Kelsey, Chris R.; Yoo, David S.; Yin, Fang-Fang; Cai, Jing, E-mail: jing.cai@duke.edu

    2014-04-01

    To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V{sub 100%}), max PTV dose (PTV D{sub max}), percentage prescription dose to 0.35 cc of cord (cord D{sub 0.35} {sub cc}), percentage prescription dose to 0.35 cc and 5 cc of esophagus (esophagus D{sub 0.35} {sub cc} and D{sub 5} {sub cc}), and volume of the lungs receiving at least 20 Gy (lung V{sub 20}). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were < 1% or < 1 Gy. Of all rotational offsets, largest change in PTV V{sub 100%}, PTV D{sub max}, cord D{sub 0.35} {sub cc}, esophagus D{sub 0.35} {sub cc}, esophagus D{sub 5} {sub cc}, and lung V{sub 20} was − 8.36%, − 6.06%, 11.96%, 8.66%, 6.02%, and − 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R{sup 2} range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5° in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets.

  5. Stereotactic radiotherapy for non-small cell lung cancer: From concept to clinical reality. 2011 update; Radiotherapie stereotaxique des cancers broncho-pulmonaires non a petites cellules: d'un concept a une realite clinique. Actualites en 2011

    Energy Technology Data Exchange (ETDEWEB)

    Girard, N. [Service de pneumologie, hopital Louis-Pradel, hospices civils de Lyon, 28, avenue du Doyen-Jean-Lepine, 69500 Bron (France); UMR 754, universite Claude-Bernard Lyon 1, 43, boulevard du 11-Novembre-1918, 69622 Villeurbanne cedex (France); Mornex, F. [Departement de radiotherapie oncologie, centre hospitalier Lyon-Sud, 165, chemin du Grand-Revoyet, 69495 Pierre-Benite cedex (France); EA 37-38, universite Claude-Bernard Lyon 1, 43, boulevard du 11-Novembre-1918, 69622 Villeurbanne cedex (France)

    2011-10-15

    Only 60% of patients with early-stage non-small cell lung cancer (NSCLC), a priori bearing a favorable prognosis, undergo radical resection because of the very frequent co-morbidities occurring in smokers, precluding surgery to be safely performed. Stereotactic radiotherapy consists of the use of multiple radiation micro-beams, allowing high doses of radiation to be delivered to the tumour (ranging from 7.5 to 20 Gy per fraction) in a small number of fractions (one to eight on average). Several studies with long-term follow-up are now available, showing the effectiveness of stereotactic radiotherapy to control stage I/II non-small cell lung cancer in medically inoperable patients. Local control rates are consistently reported to be above 95% with a median survival of 34 to 45 months. Because of these excellent results, stereotactic radiation therapy is now being evaluated in operable patients in several randomized trials with a surgical arm. Ultimately, the efficacy of stereotactic radiotherapy in early-stage tumours leads to hypothesize that it may represent an opportunity for locally-advanced tumors. The specific toxicities of stereotactic radiotherapy mostly correspond to radiation-induced chest wall side effects, especially for peripheral tumours. The use of adapted fractionation schemes has made feasible the use of stereotactic radiotherapy to treat proximal tumours. Overall, from a technical concept to the availability of specific treatment devices and the publication of clinical results, stereotactic radiotherapy represents a model of implementation in thoracic oncology. (authors)

  6. Treatment of Early Stage Non-Small Cell Lung Cancer: Surgery or Stereotactic Ablative Radiotherapy?

    Directory of Open Access Journals (Sweden)

    Esengül Koçak Uzel

    2015-03-01

    Full Text Available The management of early-stage Non-small Cell Lung Cancer (NSCLC has improved recently due to advances in surgical and radiation modalities. Minimally-invasive procedures like Video-assisted thoracoscopic surgery (VATS lobectomy decreases the morbidity of surgery, while the numerous methods of staging the mediastinum such as endobronchial and endoscopic ultrasound-guided biopsies are helping to achieve the objectives much more effectively. Stereotactic Ablative Radiotherapy (SABR has become the frontrunner as the standard of care in medically inoperable early stage NSCLC patients, and has also been branded as tolerable and highly effective. Ongoing researches using SABR are continuously validating the optimal dosing and fractionation schemes, while at the same time instituting its role for both inoperable and operable patients.

  7. Risk factors for radiation pneumonitis after stereotactic radiation therapy for lung tumours: clinical usefulness of the planning target volume to total lung volume ratio.

    Science.gov (United States)

    Ueyama, Tomoko; Arimura, Takeshi; Takumi, Koji; Nakamura, Fumihiko; Higashi, Ryutaro; Ito, Soichiro; Fukukura, Yoshihiko; Umanodan, Tomokazu; Nakajo, Masanori; Koriyama, Chihaya; Yoshiura, Takashi

    2018-06-01

    To identify risk factors for symptomatic radiation pneumonitis (RP) after stereotactic radiation therapy (SRT) for lung tumours. We retrospectively evaluated 68 lung tumours in 63 patients treated with SRT between 2011 and 2015. RP was graded according to the National Cancer Institute-Common Terminology Criteria for Adverse Events version 4.0. SRT was delivered at 7.0-12.0 Gy per each fraction, once daily, to a total of 48-64 Gy (median, 50 Gy). Univariate analysis was performed to assess patient- and treatment-related factors, including age, sex, smoking index (SI), pulmonary function, tumour location, serum Krebs von den Lungen-6 value (KL-6), dose-volume metrics (V5, V10, V20, V30, V40 and VS5), homogeneity index of the planning target volume (PTV), PTV dose, mean lung dose (MLD), contralateral MLD and V2, PTV volume, lung volume and the PTV/lung volume ratio (PTV/Lung). Performance of PTV/Lung in predicting symptomatic RP was also analysed using receiver operating characteristic (ROC) analysis. The median follow-up period was 21 months. 10 of 63 patients (15.9%) developed symptomatic RP after SRT. On univariate analysis, V10, V20, PTV volume and PTV/Lung were significantly associated with occurrence of RP  ≥Grade 2. ROC curves indicated that symptomatic RP could be predicted using PTV/Lung [area under curve (AUC): 0.88, confidence interval (CI: 0.78-0.95), cut-off value: 1.09, sensitivity: 90.0% and specificity: 72.4%]. PTV/Lung is a good predictor of symptomatic RP after SRT. Advances in knowledge: The cases with high PTV/Lung should be carefully monitored with caution for the occurrence of RP after SRT.

  8. Stereotactic body radiotherapy for lung metastases as oligo-recurrence: a single institutional study.

    Science.gov (United States)

    Aoki, Masahiko; Hatayama, Yoshiomi; Kawaguchi, Hideo; Hirose, Katsumi; Sato, Mariko; Akimoto, Hiroyoshi; Miura, Hiroyuki; Ono, Shuichi; Takai, Yoshihiro

    2016-01-01

    The purpose of this study was to investigate clinical outcomes following stereotactic body radiotherapy (SBRT) for lung metastases as oligo-recurrence. From May 2003 to June 2014, records for 66 patients with 76 oligo-recurrences in the lungs treated with SBRT were retrospectively reviewed. Oligo-recurrence primary sites and patient numbers were as follows: lungs, 31; colorectal, 13; head and neck, 10; esophagus, 3; uterus, 3; and others, 6. The median SBRT dose was 50 Gy (range, 45-60 Gy) administered in a median of 5 (range, 5-9) fractions. All patients received SBRT, with no acute toxicity. Surviving patients had a median follow-up time of 36.5 months. The 3-year rates of local control, overall survival and disease-free survival were 90.6%, 76.0% and 53.7%, respectively. Longer disease-free interval from initial treatment to SBRT, and non-colorectal cancer were both associated with favorable outcomes. Disease progression after SBRT occurred in 31 patients, most with distant metastases (n = 24) [among whom, 87.5% (n = 21) had new lung metastases]. Among these 21 patients, 12 were judged as having a second oligo-recurrence. Additional SBRT was performed for these 12 patients, and all 12 tumors were controlled without disease progression. Three patients (4.5%) developed Grade 2 radiation pneumonitis. No other late adverse events of Grade ≥2 were identified. Thus, SBRT for oligo-recurrence achieved acceptable tumor control, with additional SBRT also effective for selected patients with a second oligo-recurrence after primary SBRT. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  9. Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans

    International Nuclear Information System (INIS)

    Kroon, Petra S; Hol, Sandra; Essers, Marion

    2013-01-01

    The main aim of the current study was to assess the dosimetric accuracy and clinical quality of volumetric modulated arc therapy (VMAT) plans for stereotactic (stage I) and conventional (stage III) lung cancer treatments planned with Eclipse version 10.0 Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) algorithm. The dosimetric impact of using AAA instead of AXB, and grid size 2.5 mm instead of 1.0 mm for VMAT treatment plans was evaluated. The clinical plan quality of AXB VMAT was assessed using 45 stage I and 73 stage III patients, and was compared with published results, planned with VMAT and hybrid-VMAT techniques. The dosimetric impact on near-minimum PTV dose (D 98% ) using AAA instead of AXB was large (underdose up to 12.3%) for stage I and very small (underdose up to 0.8%) for stage III lung treatments. There were no significant differences for dose volume histogram (DVH) values between grid sizes. The calculation time was significantly higher for AXB grid size 1.0 than 2.5 mm (p < 0.01). The clinical quality of the VMAT plans was at least comparable with clinical qualities given in literature of lung treatment plans with VMAT and hybrid-VMAT techniques. The average mean lung dose (MLD), lung V 20Gy and V 5Gy in this study were respectively 3.6 Gy, 4.1% and 15.7% for 45 stage I patients and 12.4 Gy, 19.3% and 46.6% for 73 stage III lung patients. The average contra-lateral lung dose V 5Gy-cont was 35.6% for stage III patients. For stereotactic and conventional lung treatments, VMAT calculated with AXB grid size 2.5 mm resulted in accurate dose calculations. No hybrid technique was needed to obtain the dose constraints. AXB is recommended instead of AAA for avoiding serious overestimation of the minimum target doses compared to the actual delivered dose

  10. TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Goetsch, S. [San Diego Medical Physics (United States)

    2016-06-15

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  11. TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

    International Nuclear Information System (INIS)

    Goetsch, S.

    2016-01-01

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  12. Maximizing Benefits from Maintenance Pemetrexed with Stereotactic Ablative Radiotherapy in Oligoprogressive Non-Squamous Non-Small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Shao-Lun Lu

    2016-08-01

    Full Text Available Maintenance pemetrexed offers survival benefit with well-tolerated toxicities for advanced non-squamous non-small cell lung cancer (NSCLC. We present 3 consecutively enrolled patients with advanced non-squamous NSCLC, receiving stereotactic ablative radiotherapy (SABR for oligoprogressive disease during maintenance pemetrexed. All of them had sustained local control of thoracic oligoprogression after the SABR, while maintenance pemetrexed were kept for additionally long progression-free interval. SABR targeting oligoprogression with continued pemetrexed is an effective and safe approach to extend exposure of maintenance pemetrexed, thus maximizing the benefit from it.

  13. Proton-Based Stereotactic Ablative Radiotherapy in Early-Stage Non-Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Jonathan D. Grant

    2014-01-01

    Full Text Available Stereotactic ablative radiotherapy (SABR, a recent implementation in the practice of radiation oncology, has been shown to confer high rates of local control in the treatment of early stage non-small-cell lung cancer (NSCLC. This technique, which involves limited invasive procedures and reduced treatment intervals, offers definitive treatment for patients unable or unwilling to undergo an operation. The use of protons in SABR delivery confers the added physical advantage of normal tissue sparing due to the absence of collateral radiation dose delivered to regions distal to the target. This may translate into clinical benefit and a decreased risk of clinical toxicity in patients with nearby critical structures or limited pulmonary reserve. In this review, we present the rationale for proton-based SABR, principles relating to the delivery and planning of this modality, and a summary of published clinical studies.

  14. The Confluence of Stereotactic Ablative Radiotherapy and Tumor Immunology

    Directory of Open Access Journals (Sweden)

    Steven Eric Finkelstein

    2011-01-01

    Full Text Available Stereotactic radiation approaches are gaining more popularity for the treatment of intracranial as well as extracranial tumors in organs such as the liver and lung. Technology, rather than biology, is driving the rapid adoption of stereotactic body radiation therapy (SBRT, also known as stereotactic ablative radiotherapy (SABR, in the clinic due to advances in precise positioning and targeting. Dramatic improvements in tumor control have been demonstrated; however, our knowledge of normal tissue biology response mechanisms to large fraction sizes is lacking. Herein, we will discuss how SABR can induce cellular expression of MHC I, adhesion molecules, costimulatory molecules, heat shock proteins, inflammatory mediators, immunomodulatory cytokines, and death receptors to enhance antitumor immune responses.

  15. Potentially curative stereotactic body radiation therapy (SBRT) for single or oligometastasis to the lung.

    Science.gov (United States)

    Oh, Dongryul; Ahn, Yong Chan; Seo, Jeong Min; Shin, Eun Hyuk; Park, Hee Chul; Lim, Do Hoon; Pyo, Hongryull

    2012-05-01

    To analyze the treatment outcomes of a potentially curative therapy, stereotactic body radiation therapy (SBRT), for patients with single or oligometastasis to the lungs. Sixty-seven metastatic lung lesions in 57 patients were treated with SBRT between September 2001 and November 2010. All patients had single or oligo-metastasis to the lungs following a meticulous clinical work-up, including PET-CT scans. The lungs were the most common primary organ (33 lesions, 49.3%), followed by the head and neck (11 lesions, 16.4%), the liver (nine lesions, 13.5%), the colorectum (seven lesions, 10.4%), and other organs (seven lesions, 10.4%). Three different fractionation schedules were used: 50 Gy/5 fractions to four lesions (6.0%); 60 Gy/5 fractions to 44 lesions (65.7%); and 60 Gy/4 fractions to 19 lesions (28.3%). Local tumor progression occurred in three lesions (4.5%). The three-year actuarial local control rate was 94.5%. Tumors larger than or equal to 2.5 cm showed poorer local control (98.3% vs. 77.8%, p <0.01). Metastatic tumors from the liver and colorectum showed lower local control rates than those from other organs (77.8%, 85.7%, and 100%, p =0.04). The two-year overall survival rate was 57.2%. Patients with tumors smaller than 2.5 cm had more favorable survival rates (64.0% vs. 38.9% at two-year, p =0.032). Patients with extrathoracic disease had poorer survival rates (66.1% vs. 0% at two-year, p =0.003). Patients with disease-free intervals longer than two years showed a trend toward good prognosis (71.1% vs. 51.1% at two-year, p =0.106). Grade 2 lung toxicity occurred in four patients (6.0%). One patient experienced Grade 5 lung toxicity following SBRT. SBRT for single or oligo-metastasis to the lung seems quite effective and safe. Tumor size, disease-free interval, and presence of extrathoracic disease are prognosticators for survival.

  16. Potentially curative stereotactic body radiation therapy (SBRT) for single or oligometastasis to the lung

    International Nuclear Information System (INIS)

    Oh, Dongryul; Ahn, Yong Chan; Park, Hee Chul; Lim, Do Hoon; Pyo, Hongryull; Seo, Jeong Min; Shin, Eun Hyuk

    2012-01-01

    Background. To analyze the treatment outcomes of a potentially curative therapy, stereotactic body radiation therapy (SBRT), for patients with single or oligometastasis to the lungs. Material and methods. Sixty-seven metastatic lung lesions in 57 patients were treated with SBRT between September 2001 and November 2010. All patients had single or oligo-metastasis to the lungs following a meticulous clinical work-up, including PET-CT scans. The lungs were the most common primary organ (33 lesions, 49.3%), followed by the head and neck (11 lesions, 16.4%), the liver (nine lesions, 13.5%), the colorectum (seven lesions, 10.4%), and other organs (seven lesions, 10.4%). Three different fractionation schedules were used: 50 Gy/5 fractions to four lesions (6.0%); 60 Gy/5 fractions to 44 lesions (65.7%); and 60 Gy/4 fractions to 19 lesions (28.3%). Results. Local tumor progression occurred in three lesions (4.5%). The three-year actuarial local control rate was 94.5%. Tumors larger than or equal to 2.5 cm showed poorer local control (98.3% vs. 77.8%, p <0.01). Metastatic tumors from the liver and colorectum showed lower local control rates than those from other organs (77.8%, 85.7%, and 100%, p =0.04). The two-year overall survival rate was 57.2%. Patients with tumors smaller than 2.5 cm had more favorable survival rates (64.0% vs. 38.9% at two-year, p =0.032). Patients with extrathoracic disease had poorer survival rates (66.1% vs. 0% at two-year, p =0.003). Patients with disease-free intervals longer than two years showed a trend toward good prognosis (71.1% vs. 51.1% at two-year, p =0.106). Grade 2 lung toxicity occurred in four patients (6.0%). One patient experienced Grade 5 lung toxicity following SBRT. Conclusion. SBRT for single or oligo-metastasis to the lung seems quite effective and safe. Tumor size, disease-free interval, and presence of extrathoracic disease are prognosticators for survival

  17. Potentially curative stereotactic body radiation therapy (SBRT) for single or oligometastasis to the lung

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Dongryul; Ahn, Yong Chan; Park, Hee Chul; Lim, Do Hoon; Pyo, Hongryull [Dept. of Radiation Oncology, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)], Email: ahnyc@skku.edu; Seo, Jeong Min [Dept. of Nuclear Engineering, Hanyang Univ., Seoul (Korea, Republic of); Dept. of Radiological Science, Daewon Univ. College, Jecheon (Korea, Republic of); Shin, Eun Hyuk [Dept. of Radiation Oncology, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of); Dept. of Nuclear Engineering, Hanyang Univ., Seoul (Korea, Republic of)

    2012-05-15

    Background. To analyze the treatment outcomes of a potentially curative therapy, stereotactic body radiation therapy (SBRT), for patients with single or oligometastasis to the lungs. Material and methods. Sixty-seven metastatic lung lesions in 57 patients were treated with SBRT between September 2001 and November 2010. All patients had single or oligo-metastasis to the lungs following a meticulous clinical work-up, including PET-CT scans. The lungs were the most common primary organ (33 lesions, 49.3%), followed by the head and neck (11 lesions, 16.4%), the liver (nine lesions, 13.5%), the colorectum (seven lesions, 10.4%), and other organs (seven lesions, 10.4%). Three different fractionation schedules were used: 50 Gy/5 fractions to four lesions (6.0%); 60 Gy/5 fractions to 44 lesions (65.7%); and 60 Gy/4 fractions to 19 lesions (28.3%). Results. Local tumor progression occurred in three lesions (4.5%). The three-year actuarial local control rate was 94.5%. Tumors larger than or equal to 2.5 cm showed poorer local control (98.3% vs. 77.8%, p <0.01). Metastatic tumors from the liver and colorectum showed lower local control rates than those from other organs (77.8%, 85.7%, and 100%, p =0.04). The two-year overall survival rate was 57.2%. Patients with tumors smaller than 2.5 cm had more favorable survival rates (64.0% vs. 38.9% at two-year, p =0.032). Patients with extrathoracic disease had poorer survival rates (66.1% vs. 0% at two-year, p =0.003). Patients with disease-free intervals longer than two years showed a trend toward good prognosis (71.1% vs. 51.1% at two-year, p =0.106). Grade 2 lung toxicity occurred in four patients (6.0%). One patient experienced Grade 5 lung toxicity following SBRT. Conclusion. SBRT for single or oligo-metastasis to the lung seems quite effective and safe. Tumor size, disease-free interval, and presence of extrathoracic disease are prognosticators for survival.

  18. SU-E-T-643: Pure Alanine Dosimeter for Verification Dosimetry in IMRT

    International Nuclear Information System (INIS)

    Al-Karmi, Anan M.; Zraiqat, Fadi

    2015-01-01

    Purpose: The objective of this study was evaluation of accuracy of pure alanine dosimeters measuring intensity-modulated radiation therapy (IMRT) dose distributions in a thorax phantom. Methods: Alanine dosimeters were prepared in the form of 110 mg pure L-α-alanine powder filled into clear tissue-equivalent polymethylmethacrylate (PMMA) plastic tubes with the dimensions 25 mm length, 3 mm inner diameter, and 1 mm wall thickness. A dose-response calibration curve was established for the alanine by placing the dosimeters at 1.5 cm depth in a 30×30×30 cm 3 solid water phantom and then irradiating on a linac with 6 MV photon beam at 10×10 cm 2 field size to doses ranging from 1 to 5 Gy. Electron paramagnetic resonance (EPR) spectroscopy was used to determine the absorbed dose in alanine. An IMRT treatment plan was designed for a commercial heterogeneous CIRS thorax phantom and the dose values were calculated at three different points located in tissue, lung, and bone equivalent materials. A set of dose measurements was carried out to compare measured and calculated dose values by placing the alanine dosimeters at those selected locations inside the thorax phantom and delivering the IMRT to the phantom. Results: The alanine dose measurements and the IMRT plan dose calculations were found to be in agreement within ±2%. Specifically, the deviations were −0.5%, 1.3%, and −1.7% for tissue, lung, and bone; respectively. The slightly large deviations observed for lung and bone may be attributed to tissue inhomogeneity, steep dose gradients in these regions, and uncontrollable changes in spectrometer conditions. Conclusion: The results described herein confirmed that pure alanine dosimeter was suitable for in-phantom dosimetry of IMRT beams because of its high sensitivity and acceptable accuracy. This makes the dosimeter a promising option for quality control of the therapeutic beams, complementing the commonly used ionization chambers, TLDs, and films

  19. Stereotactic body radiotherapy (sbrt) in lung oligometastatic patients: role of local treatments

    International Nuclear Information System (INIS)

    Navarria, Pierina; Tozzi, Angelo; Reggiori, Giacomo; Fogliata, Antonella; Scorsetti, Marta; Ascolese, Anna Maria; Tomatis, Stefano; Cozzi, Luca; De Rose, Fiorenza; Mancosu, Pietro; Alongi, Filippo; Clerici, Elena; Lobefalo, Francesca

    2014-01-01

    Data in the literature suggest the existence of oligometastatic disease, a state in which metastases are limited in number and site. Different kinds of local therapies have been used for the treatment of limited metastases and in the recent years reports on the use of Stereotactic Ablative radiotherapy (SABR) are emerging and the early results on local control are promising. From October 2010 to February 2012, 76 consecutive patients for 118 lung lesions were treated. SABR was performed in case of controlled primary tumor, long-term of progression disease, exclusion of surgery, and number of metastatic sites ≤ 5. Different kinds of primary tumors were treated, the most common were lung and colon-rectal cancer. The total dose prescribed varied according to tumor site and maximum diameter. Dose prescription was 48 Gy in 4 fractions for peripheral lesions, 60 Gy in 8 fractions for central lesions and 60 Gy in 3 fractions for peripheral lesions with diameter ≤ 2 cm. Dosimetric planning objectives were met for the cohort of patients with in particular V98% = 98.1 ± 3.4% for the CTV and mean lung dose of 3.7 ± 3.8 Gy. Radiological response was obtained in the vast majority of patients. The local control at 1, 2 and 3 years was 95%, 89% and 89% respectively. No major pulmonary toxicity, chest pain or rib fracture occurred. The median follow up was 20 months (range 6–45 months). Overall Survival (OS) at 1, 2 and 3 years was 84.1%, 73% and 73% respectively. SABR is feasible with limited morbidity and promising results in terms of local contro, survival and toxicity

  20. Efficient and accurate stereotactic radiotherapy using flattening filter free beams and HexaPOD robotic tables

    DEFF Research Database (Denmark)

    Nielsen, Morten; Hansen, C. R.; Brink, C.

    2016-01-01

    Flattening filter free (FFF) high dose rate beam technique was introduced for brain stereotactic radiosurgery (SRS) and lung Stereotactic Body Radiotherapy (SBRT). Furthermore, a HexaPOD treatment table was introduced for the brain SRS to enable correction of rotational setup errors. 19 filter fl...

  1. Fractionated stereotactic radiotherapy in brain tumors and cervical region. Experience of the Dean Funes Medical Center, first experience in stereotactic radiotherapy and radiosurgery inside the country

    International Nuclear Information System (INIS)

    Castro Vita, H.; Brunetto, M.; Derechinsky, V; Derechinsky, G.; Derechinsky, M.; Gonzalez, S.; Marinello, A.

    2004-01-01

    Purpose: A retrospective study to analyze the results of 53 patients treated with stereotactic radiotherapy in 'Centro Medico Dean Funes' was performed. The patients had brain and head and neck tumors. Patients and methods: From November 1997 to March 2003, 53 patients were treated with stereotactic radiotherapy in 'Centro Medico Dean Funes'. The daily dose administered varied from 1.8 to 2 Gy and the total dose from 30 to 70 Gy. The minimal follow up was 2 months, and the medium follow up 32 months. Local control and survival were analyzed in all patients, as well as tolerance and the complications of the treatment. Results: Since these series represented a very heterogeneous group of patients, the final results were very difficult to compare with other alternative treatments. However, an excellent tolerance to therapy was observed. Some subsets of patients had good results to treatment: patients with metastasis to the orbit, patients with lesions to the sellar and parasellar regions and some who relapsed following conventional radiotherapy, mainly lymphomas. Conclusions: Stereotactic radiotherapy is a valid therapeutic method to treat tumors of the brain and head and neck, as long as the tumor has a moderate size (6 cm. or less) and the shape is cylindrical or ellipsoid. Stereotactic radiation improves the therapeutic ratio as compared with the conventional radiotherapy. It has advantages over the 3D technique, and could compete with IMRT (Intensity modulated radiation therapy). (author) [es

  2. Stereotactic Body Radiotherapy (SBRT) for Operable Stage I Non-Small-Cell Lung Cancer: Can SBRT Be Comparable to Surgery?

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Hiroshi, E-mail: honishi@yamanashi.ac.jp [School of Medicine, Yamanashi University, Yamanashi (Japan); Shirato, Hiroki [School of Medicine, Hokkaido University, Sapporo (Japan); Nagata, Yasushi [School of Medicine, Hiroshima University, Hiroshima (Japan); Hiraoka, Masahiro [School of Medicine, Kyoto University, Kyoto (Japan); Fujino, Masaharu [School of Medicine, Hokkaido University, Sapporo (Japan); School of Medicine, Yamanashi University, Yamanashi (Japan); Gomi, Kotaro [Cancer Institute Suwa Red-Cross Hospital, Suwa (Japan); Karasawa, Katsuyuki [Tokyo Metropolitan Komagome Hospital, Tokyo (Japan); Hayakawa, Kazushige; Niibe, Yuzuru [Kitasato University, Kanagawa (Japan); Takai, Yoshihiro [School of Medicine, Hirosaki University, Hirosaki (Japan); Kimura, Tomoki [School of Medicine, Kagawa University, Hiroshima (Japan); Takeda, Atsuya [Ofuna Chuo Hospital, Kanagawa (Japan); Ouchi, Atsushi [Keijinkai Hospital, Sapporo (Japan); Hareyama, Masato [Sapporo Medical University, Sapporo (Japan); Kokubo, Masaki [Institute of Biomedical Research and Innovation, Kobe (Japan); Kozuka, Takuyo [School of Cancer Institute Ariake Hospital, Tokyo (Japan); Arimoto, Takuro [Kitami Red Cross Hospital, Kitami (Japan); Hara, Ryusuke [National Institute of Radiological Science, Chiba (Japan); Itami, Jun [National Cancer Center, Tokyo (Japan); Araki, Tsutomu [School of Medicine, Yamanashi University, Yamanashi (Japan)

    2011-12-01

    Purpose: To review treatment outcomes for stereotactic body radiotherapy (SBRT) in medically operable patients with Stage I non-small-cell lung cancer (NSCLC), using a Japanese multi-institutional database. Patients and Methods: Between 1995 and 2004, a total of 87 patients with Stage I NSCLC (median age, 74 years; T1N0M0, n = 65; T2N0M0, n = 22) who were medically operable but refused surgery were treated using SBRT alone in 14 institutions. Stereotactic three-dimensional treatment was performed using noncoplanar dynamic arcs or multiple static ports. Total dose was 45-72.5 Gy at the isocenter, administered in 3-10 fractions. Median calculated biological effective dose was 116 Gy (range, 100-141 Gy). Data were collected and analyzed retrospectively. Results: During follow-up (median, 55 months), cumulative local control rates for T1 and T2 tumors at 5 years after SBRT were 92% and 73%, respectively. Pulmonary complications above Grade 2 arose in 1 patient (1.1%). Five-year overall survival rates for Stage IA and IB subgroups were 72% and 62%, respectively. One patient who developed local recurrences safely underwent salvage surgery. Conclusion: Stereotactic body radiotherapy is safe and promising as a radical treatment for operable Stage I NSCLC. The survival rate for SBRT is potentially comparable to that for surgery.

  3. Stereotactic Body Radiotherapy (SBRT) for Operable Stage I Non–Small-Cell Lung Cancer: Can SBRT Be Comparable to Surgery?

    International Nuclear Information System (INIS)

    Onishi, Hiroshi; Shirato, Hiroki; Nagata, Yasushi; Hiraoka, Masahiro; Fujino, Masaharu; Gomi, Kotaro; Karasawa, Katsuyuki; Hayakawa, Kazushige; Niibe, Yuzuru; Takai, Yoshihiro; Kimura, Tomoki; Takeda, Atsuya; Ouchi, Atsushi; Hareyama, Masato; Kokubo, Masaki; Kozuka, Takuyo; Arimoto, Takuro; Hara, Ryusuke; Itami, Jun; Araki, Tsutomu

    2011-01-01

    Purpose: To review treatment outcomes for stereotactic body radiotherapy (SBRT) in medically operable patients with Stage I non–small-cell lung cancer (NSCLC), using a Japanese multi-institutional database. Patients and Methods: Between 1995 and 2004, a total of 87 patients with Stage I NSCLC (median age, 74 years; T1N0M0, n = 65; T2N0M0, n = 22) who were medically operable but refused surgery were treated using SBRT alone in 14 institutions. Stereotactic three-dimensional treatment was performed using noncoplanar dynamic arcs or multiple static ports. Total dose was 45–72.5 Gy at the isocenter, administered in 3–10 fractions. Median calculated biological effective dose was 116 Gy (range, 100–141 Gy). Data were collected and analyzed retrospectively. Results: During follow-up (median, 55 months), cumulative local control rates for T1 and T2 tumors at 5 years after SBRT were 92% and 73%, respectively. Pulmonary complications above Grade 2 arose in 1 patient (1.1%). Five-year overall survival rates for Stage IA and IB subgroups were 72% and 62%, respectively. One patient who developed local recurrences safely underwent salvage surgery. Conclusion: Stereotactic body radiotherapy is safe and promising as a radical treatment for operable Stage I NSCLC. The survival rate for SBRT is potentially comparable to that for surgery.

  4. Differences in pulmonary function before vs. 1 year after hypofractionated stereotactic radiotherapy for small peripheral lung tumors

    International Nuclear Information System (INIS)

    Ohashi, Toshio; Takeda, Atsuya; Shigematsu, Naoyuki; Kunieda, Etsuo; Ishizaka, Akitoshi; Fukada, Junichi; Deloar, Hossain M.; Kawaguchi, Osamu; Takeda, Toshiaki; Takemasa, Kazuhiko; Isobe, Kouichi; Kubo, Atsushi

    2005-01-01

    Purpose: To evaluate long-term pulmonary toxicity of stereotactic radiotherapy (SRT) by pulmonary function tests (PFTs) performed before and after SRT for small peripheral lung tumors. Methods and Materials: A total of 17 lesions in 15 patients with small peripheral lung tumors, who underwent SRT between February 2000 and April 2003, were included in this study. Twelve patients had primary lung cancer, and 3 patients had metastatic lung cancer. Primary lung cancer was T1-2N0M0 in all cases. Smoking history was assessed by the Brinkman index (number of cigarettes smoked per day multiplied by number of years of smoking). Prescribed radiation doses at the 80% isodose line were 40-60 Gy in 5-8 fractions. PFTs were performed immediately before SRT and 1 year after SRT. Test parameters included total lung capacity (TLC), vital capacity (VC), forced expiratory volume in 1 s (FEV1.0), and diffusing capacity of lung for carbon monoxide (DLCO). PFT changes were evaluated in relation to patient- and treatment-related factors, including age, the Brinkman index, internal target volume, the percentages of lung volume irradiated with >15, 20, 25, and 30 Gy (V15, V20, V25, and V30, respectively), and mean lung dose. Results: There were no significant changes in TLC, VC, or FEV1.0 before vs. after SRT. The mean percent change from baseline in DLCO was significantly increased by 128.2%. Univariate and multivariate analyses revealed a correlation between DLCO and the Brinkman index. Conclusions: One year after SRT as compared with before SRT, there were no declines in TLC, VC, and FEV1.0. DLCO improved in patients who had been heavy smokers before SRT, suggesting a correlation between DLCO and smoking cessation. SRT seems to be tolerable in view of long-term lung function

  5. Extracranial stereotactic radiotherapy: Evaluation of PTV coverage and dose conformity

    International Nuclear Information System (INIS)

    Haedinger, U.; Thiele, W.; Wulf, J.

    2002-01-01

    During the past few years the concept of cranial sterotactic radiotherapy has been successfully extended to extracranial tumoral targets. In our department, hypofractionated treatment of tumours in lung, liver, abdomen, and pelvis is performed in the Stereotactic Body Frame (ELEKTA Instrument AB) since 1997. We present the evaluation of 63 consecutively treated targets (22 lung, 21 liver, 20 abdomen/pelvis) in 58 patients with respect to dose coverage of the planning target volume (PTV) as well as conformity of the dose distribution. The mean PTV coverage was found to be 96.3%±2.3% (lung), 95.0%±4.5% (liver), and 92.1%±5.2% (abdomen/pelvis). For the so-called conformation number we obtained values of 0.73±0.09 (lung), 0.77±0.10 (liver), and 0.70±0.08 (abdomen/pelvis). The results show that highly conformal treatment techniques can be applied also in extracranial stereotactic radiotherapy. This is primarily due to the relatively simple geometrical shape of most of the targets. Especially lung and liver targets turned out to be approximately spherically/cylindrically shaped, so that the dose distribution can be easily tailored by rotational fields. (orig.) [de

  6. Lung tumor motion change during stereotactic body radiotherapy (SBRT): an evaluation using MRI

    Science.gov (United States)

    Olivier, Kenneth R.; Li, Jonathan G.; Liu, Chihray; Newlin, Heather E.; Schmalfuss, Ilona; Kyogoku, Shinsuke; Dempsey, James F.

    2014-01-01

    The purpose of this study is to investigate changes in lung tumor internal target volume during stereotactic body radiotherapy treatment (SBRT) using magnetic resonance imaging (MRI). Ten lung cancer patients (13 tumors) undergoing SBRT (48 Gy over four consecutive days) were evaluated. Each patient underwent three lung MRI evaluations: before SBRT (MRI‐1), after fraction 3 of SBRT (MRI‐3), and three months after completion of SBRT (MRI‐3m). Each MRI consisted of T1‐weighted images in axial plane through the entire lung. A cone‐beam CT (CBCT) was taken before each fraction. On MRI and CBCT taken before fractions 1 and 3, gross tumor volume (GTV) was contoured and differences between the two volumes were compared. Median tumor size on CBCT before fractions 1 (CBCT‐1) and 3 (CBCT‐3) was 8.68 and 11.10 cm3, respectively. In 12 tumors, the GTV was larger on CBCT‐3 compared to CBCT‐1 (median enlargement, 1.56 cm3). Median tumor size on MRI‐1, MRI‐3, and MRI‐3m was 7.91, 11.60, and 3.33 cm3, respectively. In all patients, the GTV was larger on MRI‐3 compared to MRI‐1 (median enlargement, 1.54 cm3). In all patients, GTV was smaller on MRI‐3m compared to MRI‐1 (median shrinkage, 5.44 cm3). On CBCT and MRI, all patients showed enlargement of the GTV during the treatment week of SBRT, except for one patient who showed minimal shrinkage (0.86 cm3). Changes in tumor volume are unpredictable; therefore, motion and breathing must be taken into account during treatment planning, and image‐guided methods should be used, when treating with large fraction sizes. PACS number: 87.53.Ly PMID:24892328

  7. Domestic comparison of radiation treatment techniques for breast cancer: 3D-CRT, IMRT and VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bo Ram; Yoon, Myong Geun [Dept. of Bio-convergence Engineering, College of Health Science, Korea University, Seoul (Korea, Republic of); Lee, Sun Young [Dept. of Radiation Oncology, Yusung Sun Medical Center, Daejeon (Korea, Republic of)

    2013-09-15

    The purpose of this study is to compare method in the treatment of breast cancer using dose index. And, it is to find the optimized treatment technique to the patient. The phantom filled with tissue-equivalent material were used simulation and treatment as techniques of 3D-CRT, IMRT, VMAT was planned using Eclipse v10. By using HI(homogeneity index), CI(Conformity index), OE (Organ equivalent dose), EAR(Excess Absolute Risk), were assessed for each treatment plans. HI and CI of 3D-CRT, IMRT, VMAT were calculated 16.89, 11.21, 9.55 and 0.59, 0.61, 0.83. The organ average doses of Lt lung, Rt lung, liver, heart, esophagus, cord, Lt breast, trachea and stomach were 0.01 ∼ 2.02 Gy, 0.36 ∼ 5.01 Gy, 0.25 ∼ 2.49 Gy, 0.14 ∼ 6.92 Gy, 0.03 ∼ 2.02 Gy, 0.01 ∼ 1.06 Gy, 0.25 ∼ 6.08 Gy, 0.08 ∼ 0.59 Gy, 0.01 ∼ 1.34 Gy, respectively. The OED, EAR of the IMRT and VMAT show higher than 3D-CRT. As the result of this study, we could confirm being higher dose index(HI, CI) in IMRT and VMAT than 3D-CRT, but doses of around normal organs was higher IMRT, VMAT than 3D-CRT.

  8. TH-A-BRC-03: AAPM TG218: Measurement Methods and Tolerance Levels for Patient-Specific IMRT Verification QA

    Energy Technology Data Exchange (ETDEWEB)

    Miften, M. [University of Colorado School of Medicine (United States)

    2016-06-15

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  9. TH-A-BRC-03: AAPM TG218: Measurement Methods and Tolerance Levels for Patient-Specific IMRT Verification QA

    International Nuclear Information System (INIS)

    Miften, M.

    2016-01-01

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  10. A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware.

    Science.gov (United States)

    Rosca, Florin

    2012-06-01

    To present a mixed electron and photon IMRT planning technique using electron beams with an energy range of 6-22 MeV and standard hardware that minimizes integral dose to patients for targets as deep as 7.5 cm. Ten brain cases, two lung, a thyroid, an abdominal, and a parotid case were planned using two planning techniques: a photon-only IMRT (IMRT) versus a mixed modality treatment (E+IMRT) that includes an enface electron beam and a photon IMRT portion that ensures a uniform target coverage. The electron beam is delivered using a regular cutout placed in an electron cone. The electron energy was chosen to provide a good trade-off between minimizing integral dose and generating a uniform, deliverable plan. The authors choose electron energies that cover the deepest part of PTV with the 65%-70% isodose line. The normal tissue integral dose, the dose for ring structures around the PTV, and the volumes of the 75%, 50%, and 25% isosurfaces were used to compare the dose distributions generated by the two planning techniques. The normal tissue integral dose was lowered by about 20% by the E+IMRT plans compared to the photon-only IMRT ones for most studied cases. With the exception of lungs, the dose reduction associated to the E+IMRT plans was more pronounced further away from the target. The average dose ratio delivered to the 0-2 cm and the 2-4 cm ring structures for brain patients for the two planning techniques were 89.6% and 70.8%, respectively. The enhanced dose sparing away from the target for the brain patients can also be observed in the ratio of the 75%, 50%, and 25% isodose line volumes for the two techniques, which decreases from 85.5% to 72.6% and further to 65.1%, respectively. For lungs, the lateral electron beams used in the E+IMRT plans were perpendicular to the mostly anterior/posterior photon beams, generating much more conformal plans. The authors proved that even using the existing electron delivery hardware, a mixed electron/photon planning

  11. Chest Wall Volume Receiving >30 Gy Predicts Risk of Severe Pain and/or Rib Fracture After Lung Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Dunlap, Neal E.; Cai, Jing; Biedermann, Gregory B.; Yang, Wensha; Benedict, Stanley H.; Sheng Ke; Schefter, Tracey E.; Kavanagh, Brian D.; Larner, James M.

    2010-01-01

    Purpose: To identify the dose-volume parameters that predict the risk of chest wall (CW) pain and/or rib fracture after lung stereotactic body radiotherapy. Methods and Materials: From a combined, larger multi-institution experience, 60 consecutive patients treated with three to five fractions of stereotactic body radiotherapy for primary or metastatic peripheral lung lesions were reviewed. CW pain was assessed using the Common Toxicity Criteria for pain. Peripheral lung lesions were defined as those located within 2.5 cm of the CW. A minimal point dose of 20 Gy to the CW was required. The CW volume receiving ≥20, ≥30, ≥40, ≥50, and ≥60 Gy was determined and related to the risk of CW toxicity. Results: Of the 60 patients, 17 experienced Grade 3 CW pain and five rib fractures. The median interval to the onset of severe pain and/or fracture was 7.1 months. The risk of CW toxicity was fitted to the median effective concentration dose-response model. The CW volume receiving 30 Gy best predicted the risk of severe CW pain and/or rib fracture (R 2 = 0.9552). A volume threshold of 30 cm 3 was observed before severe pain and/or rib fracture was reported. A 30% risk of developing severe CW toxicity correlated with a CW volume of 35 cm 3 receiving 30 Gy. Conclusion: The development of CW toxicity is clinically relevant, and the CW should be considered an organ at risk in treatment planning. The CW volume receiving 30 Gy in three to five fractions should be limited to 3 , if possible, to reduce the risk of toxicity without compromising tumor coverage.

  12. Analysis of the impact of chest wall constraints on eligibility for a randomized trial of stereotactic body radiotherapy of peripheral stage 1 non-small cell lung cancer

    International Nuclear Information System (INIS)

    Siva, Shankar; Shaw, Mark; Gill, Suki; David, Ball; Chesson, Brent

    2012-01-01

    Chest wall toxicities are recognized complications of stereotactic radiotherapy (SBRT) in non-small cell lung cancer. To minimize toxicity, the Trans-Tasman Radiation Oncology Group (TROG) 09.02 ‘CHISEL’ study protocol excluded patients with tumours within 1cm of the chest wall. The purpose of this study is to evaluate the implication of chest wall proximity constraints on patient eligibility, toxicity and potential accrual. Exclusion zones of 1cm beyond the mediastinum and 2cm beyond the bifurcation of the lobar bronchi were incorporated into the CHISEL credentialing CT dataset. Volumes of lung within which tumours varying from 1cm to 5cm in diameter may occupy and remain eligible for the CHISEL study were calculated. These volumes were compared to a hypothetical model in which the 1cm chest wall proximity restriction was removed. The percentage of lung area in which a tumour mass can occupy and be suitable for CHISEL in the left and right lung were 54% and 60% respectively. Removing the constraint increased the percentage of available lung to 83% and 87% respectively. Considering a 2cm spherical tumour, only 21% and 31% of tumours in the left and right lung would be eligible with the chest wall constraint, whilst 39% and 50% respectively would be eligible without the constraint. The exclusion of tumours less than 1cm to chest wall significantly reduces the proportion of patients eligible for the CHISEL protocol. A review of the literature pertaining to chest wall toxicity after stereotactic radiotherapy supports a change in chest wall exclusion criteria for the CHISEL study.

  13. Statistical analysis of target motion in gated lung stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Zhao Bo; Yang Yong; Li Tianfang; Li Xiang; Heron, Dwight E; Huq, M Saiful

    2011-01-01

    An external surrogate-based respiratory gating technique is a useful method to reduce target margins for the treatment of a moving lung tumor. The success of this technique relies on a good correlation between the motion of the external markers and the internal tumor as well as the repeatability of the respiratory motion. In gated lung stereotactic body radiation therapy (SBRT), the treatment time for each fraction could exceed 30 min due to large fractional dose. Tumor motion may experience pattern changes such as baseline shift during such extended treatment time. The purpose of this study is to analyze tumor motion traces in actual treatment situations and to evaluate the effect of the target baseline shift in gated lung SBRT treatment. Real-time motion data for both the external markers and tumors from 51 lung SBRT treatments with Cyberknife Synchrony technology were analyzed in this study. The treatment time is typically greater than 30 min. The baseline shift was calculated with a rolling average window equivalent to ∼20 s and subtracted from that at the beginning. The magnitude of the baseline shift and its relationship with treatment time were investigated. Phase gating simulation was retrospectively performed on 12 carefully selected treatments with respiratory amplitude larger than 5 mm and regular phases. A customized gating window was defined for each individual treatment. It was found that the baseline shifts are specific to each patient and each fraction. Statistical analysis revealed that more than 69% treatments exhibited increased baseline shifts with the lapse of treatment time. The magnitude of the baseline shift could reach 5.3 mm during a 30 min treatment. Gating simulation showed that tumor excursion was caused mainly by the uncertainties in phase gating simulation and baseline shift, the latter being the primary factor. With a 5 mm gating window, 2 out of 12 treatments in the study group showed significant tumor excursion. Baseline shifts

  14. Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver.

    Science.gov (United States)

    Wulf, Jörn; Hädinger, Ulrich; Oppitz, Ulrich; Thiele, Wibke; Flentje, Michael

    2003-02-01

    Previous analyses of target reproducibility in extracranial stereotactic radiotherapy have revealed standard security margins for planning target volume (PTV) definition of 5mm in axial and 5-10mm in longitudinal direction. In this study the reproducibility of the clinical target volume (CTV) of lung and liver tumors within the PTV over the complete course of hypofractionated treatment is evaluated. The impact of target mobility on dose to the CTV is assessed by dose-volume histograms (DVH). Twenty-two pulmonary and 21 hepatic targets were treated with three stereotactic fractions of 10 Gy to the PTV-enclosing 100%-isodose with normalization to 150% at the isocenter. A conformal dose distribution was related to the PTV, which was defined by margins of 5-10mm added to the CTV. Prior to each fraction a computed tomography (CT)-simulation over the complete target volume was performed resulting in a total of 60 CT-simulations for lung and 58 CT-simulations for hepatic targets. The CTV from each CT-simulation was segmented and matched with the CT-study used for treatment planning. A DVH of the simulated CTV was calculated for each fraction. The target coverage (TC) of dose to the simulated CTV was defined as the proportion of the CTV receiving at least the reference dose (100%). A decrease of TC to or=95% at each fraction of treatment. Pulmonary targets with increased breathing mobility and liver tumors >100 cm(3) are at risk for target deviation exceeding the standard security margins for PTV-definition at least for one fraction and require individual evaluation of sufficient margins.

  15. Outcomes of Stereotactic Body Radiotherapy (SBRT) treatment of multiple synchronous and recurrent lung nodules

    International Nuclear Information System (INIS)

    Owen, Dawn; Olivier, Kenneth R; Mayo, Charles S; Miller, Robert C; Nelson, Kathryn; Bauer, Heather; Brown, Paul D; Park, Sean S; Ma, Daniel J; Garces, Yolanda I

    2015-01-01

    Stereotactic body radiotherapy (SBRT) is evolving into a standard of care for unresectable lung nodules. Local control has been shown to be in excess of 90% at 3 years. However, some patients present with synchronous lung nodules in the ipsilateral or contralateral lobe or metasynchronous disease. In these cases, patients may receive multiple courses of lung SBRT or a single course for synchronous nodules. The toxicity of such treatment is currently unknown. Between 2006 and 2012, 63 subjects with 128 metasynchronous and synchronous lung nodules were treated at the Mayo Clinic with SBRT. Demographic patient data and dosimetric data regarding SBRT treatments were collected. Acute toxicity (defined as toxicity < 90 days) and late toxicity (defined as toxicity > = 90 days) were reported and graded as per standardized CTCAE 4.0 criteria. Local control, progression free survival and overall survival were also described. The median age of patients treated was 73 years. Sixty five percent were primary or recurrent lung cancers with the remainder metastatic lung nodules of varying histologies. Of 63 patients, 18 had prior high dose external beam radiation to the mediastinum or chest. Dose and fractionation varied but the most common prescriptions were 48 Gy/4 fractions, 54 Gy/3 fractions, and 50 Gy/5 fractions. Only 6 patients demonstrated local recurrence. With a median follow up of 12.6 months, median SBRT specific overall survival and progression free survival were 35.7 months and 10.7 months respectively. Fifty one percent (32/63 patients) experienced acute toxicity, predominantly grade 1 and 2 fatigue. One patient developed acute grade 3 radiation pneumonitis at 75 days. Forty six percent (29/63 patients) developed late effects. Most were grade 1 dyspnea. There was one patient with grade 5 pneumonitis. Multiple courses of SBRT and SBRT delivery after external beam radiotherapy appear to be feasible and safe. Most toxicity was grade 1 and 2 but the risk was

  16. Influence of rotational setup error on tumor shift in bony anatomy matching measured with pulmonary point registration in stereotactic body radiotherapy for early lung cancer

    International Nuclear Information System (INIS)

    Suzuki, Osamu; Nishiyama, Kinji; Ueda, Yoshihiro; Miyazaki, Masayoshi; Tsujii, Katsutomo

    2012-01-01

    The objective of this study was to examine the correlation between the patient rotational error measured with pulmonary point registration and tumor shift after bony anatomy matching in stereotactic body radiotherapy for lung cancer. Twenty-six patients with lung cancer who underwent stereotactic body radiotherapy were the subjects. On 104 cone-beam computed tomography measurements performed prior to radiation delivery, rotational setup errors were measured with point registration using pulmonary structures. Translational registration using bony anatomy matching was done and the three-dimensional vector of tumor displacement was measured retrospectively. Correlation among the three-dimensional vector and rotational error and vertebra-tumor distance was investigated quantitatively. The median and maximum rotational errors of the roll, pitch and yaw were 0.8, 0.9 and 0.5, and 6.0, 4.5 and 2.5, respectively. Bony anatomy matching resulted in a 0.2-1.6 cm three-dimensional vector of tumor shift. The shift became larger as the vertebra-tumor distance increased. Multiple regression analysis for the three-dimensional vector indicated that in the case of bony anatomy matching, tumor shifts of 5 and 10 mm were expected for vertebra-tumor distances of 4.46 and 14.1 cm, respectively. Using pulmonary point registration, it was found that the rotational setup error influences the tumor shift. Bony anatomy matching is not appropriate for hypofractionated stereotactic body radiotherapy with a tight margin. (author)

  17. Evaluation and performance of arccheck and film using gamma criteria in pre-treatment quality assurance of stereotactic ablative radiotherapy

    Directory of Open Access Journals (Sweden)

    Prabhakar Ramachandran

    2017-01-01

    Full Text Available Aim: The aim of this study is to assess the use of ArcCHECK (AC as an alternative method to replace film dosimetry for pre-treatment quality assurance (QA of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy (IMRT, and volumetric-modulated arc therapy (VMAT stereotactic ablative radiotherapy (SABR treatment plans. Materials and Methods: Twenty-five patients with a varied diagnosis of lung, spine, sacrum, sternum, ribs, scapula, and femur undergoing SABR were selected for this study. Pre-treatment QA was performed for all the patients using ionization chamber and film dosimetry. Measurements were also carried out on an AC phantom. The planned and measured doses from the AC device and EBT3 films were compared using four different gamma criteria: 2%/2 mm, 3%/2 mm, 3%/1 mm, and 3%/3 mm. Results: The mean gamma passing rates at 3%/3 mm for all non-spine SABR cases were 98.79 ± 0.96 and 99.27 ± 1.03 with AC and films, respectively. The mean passing rates at 3%/2 mm for AC and films were 98.76 ± 0.42 and 99.43 ± 0.27 respectively for spine VMAT SABR, and 87.15 ± 2.45 and 99.79 ± 0.14 respectively for spine IMRT SABR. In the case of spine tumors, the gamma criterion was tightened due to the proximity of spinal cord to the planning target volume. Our results show that AC provides good results for all VMAT SABR plans. Conclusion: The AC results at 3%/3 mm were in good agreement with film dosimetry for most cases. We observed a significant reduction in QA time on using AC for SABR QA. This study showed that AC results are comparable to film dosimetry for all studied sites except for spine IMRT SABR.

  18. Cardiac dose-sparing effects of deep-inspiration breath-hold in left breast irradiation. Is IMRT more beneficial than VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Sakka, Mazen; Grabenbauer, Gerhard G. [Coburg Cancer Center, Department of Radiation Oncology, Coburg (Germany); Friedrich-Alexander University of Erlangen-Nuernberg, Faculty of Medicine, Erlangen (Germany); Kunzelmann, Leonie; Metzger, Martin [Coburg Cancer Center, Department of Radiation Oncology, Coburg (Germany)

    2017-10-15

    Given the reduction in death from breast cancer, as well as improvements in overall survival, adjuvant radiotherapy is considered the standard treatment for breast cancer. However, left-sided breast irradiation was associated with an increased rate of fatal cardiovascular events due to incidental irradiation of the heart. Recently, considerable efforts have been made to minimize cardiac toxicity of left-sided breast irradiation by new treatment methods such as deep-inspiration breath-hold (DIBH) and new radiation techniques, particularly intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). The primary aim of this study was to evaluate the effect of DIBH irradiation on cardiac dose compared with free-breathing (FB) irradiation, while the secondary objective was to compare the advantages of IMRT versus VMAT plans in both the FB and the DIBH position for left-sided breast cancer. In all, 25 consecutive left-sided breast cancer patients underwent CT simulation in the FB and DIBH position. Five patients were excluded with no cardiac displacement following DIBH-CT simulation. The other 20 patients were irradiated in the DIBH position using respiratory gating. Four different treatment plans were generated for each patient, an IMRT and a VMAT plan in the DIBH and in the FB position, respectively. The following parameters were used for plan comparison: dose to the heart, left anterior descending coronary artery (mean dose, maximum dose, D25% and D45%), ipsilateral, contralateral lung (mean dose, D20%, D30%) and contralateral breast (mean dose). The percentage in dose reduction for organs at risk achieved by DIBH for both IMRT and VMAT plans was calculated and compared for each patient by each treatment plan. DIBH irradiation significantly reduced mean dose to the heart and left anterior descending coronary artery (LADCA) using both IMRT (heart -20%; p = 0.0002, LADCA -9%; p = 0.001) and VMAT (heart -23%; p = 0.00003, LADCA -16%; p = 0

  19. Dose impact of a carbon fiber couch for stereotactic body radiation therapy of lung tumors

    International Nuclear Information System (INIS)

    Tominaga, Hirofumi; Kanetake, Nagisa; Kawasaki, Keiichi; Iwashita, Yuki; Sakata, Junichi; Okuda, Tomoko; Araki, Fujio; Shimohigashi, Yoshinobu; Tomiyama, Yuki

    2013-01-01

    The aim of this study was to measure the dose attenuation caused by a carbon fiber radiation therapy table (Imaging Couch Top; ICT, BrainLab) and to evaluate the dosimetric impact of ICT during stereotactic body radiation therapy (SBRT) in lung tumors. The dose attenuation of ICT was measured using an ionization chamber and modeled by means of a treatment planning system (TPS). SBRT was planned with and without ICT in a lung tumor phantom and ten cases of clinical lung tumors. The results were analyzed from isocenter doses and a dose-volume histogram (DVH): D 95 , D mean , V 20 , V 5 , homogeneity index (HI), and conformity index (CI). The dose attenuation of the ICT modeled with TPS agreed to within ±1% of the actually measured values. The isocenter doses, D 95 and D mean with and without ICT showed differences of 4.1-5% for posterior single field and three fields in the phantom study, and differences of 0.6-2.4% for five fields and rotation in the phantom study and six fields in ten clinical cases. The dose impact of ICT was not significant for five or more fields in SBRT. It is thus possible to reduce the dose effect of ICT by modifying the beam angle and beam weight in the treatment plan. (author)

  20. Stereotactic body radiotherapy for centrally located early-stage non-small cell lung cancer or lung metastases from the RSSearch® patient registry

    International Nuclear Information System (INIS)

    Davis, Joanne N.; Medbery, Clinton; Sharma, Sanjeev; Pablo, John; Kimsey, Frank; Perry, David; Muacevic, Alexander; Mahadevan, Anand

    2015-01-01

    The purpose of this study was to evaluate treatment patterns and outcomes of stereotactic body radiotherapy (SBRT) for centrally located primary non-small cell lung cancer (NSCLC) or lung metastases from the RSSearch ® Patient Registry, an international, multi-center patient registry dedicated to radiosurgery and SBRT. Eligible patients included those with centrally located lung tumors clinically staged T1-T2 N0, M0, biopsy-confirmed NSCLC or lung metastases treated with SBRT between November 2004 and January 2014. Descriptive analysis was used to report patient demographics and treatment patterns. Overall survival (OS) and local control (LC) were determined using Kaplan-Meier method. Toxicity was reported using the Common Terminology Criteria for Adverse Events version 3.0. In total, 111 patients with 114 centrally located lung tumors (48 T1-T2,N0,M0 NSCLC and 66 lung metastases) were treated with SBRT at 19 academic and community-based radiotherapy centers in the US and Germany. Median follow-up was 17 months (range, 1–72). Median age was 74 years for primary NSCLC patients and 65 years for lung metastases patients (p < 0.001). SBRT dose varied from 16 – 60 Gy (median 48 Gy) delivered in 1–5 fractions (median 4 fractions). Median dose to centrally located primary NSCLC was 48 Gy compared to 37.5 Gy for lung metastases (p = 0.0001) and median BED 10 was 105.6 Gy for primary NSCLC and 93.6 Gy for lung metastases (p = 0.0005). Two-year OS for T1N0M0 and T2N0M0 NSCLC was 79 and 32.1 %, respectively (p = 0.009) and 2-year OS for lung metastases was 49.6 %. Two-year LC was 76.4 and 69.8 % for primary NSCLC and lung metastases, respectively. Toxicity was low with no Grade 3 or higher acute or late toxicities. Overall, patients with centrally located primary NSCLC were older and received higher doses of SBRT than those with lung metastases. Despite these differences, LC and OS was favorable for patients with central lung tumors treated with SBRT. Reported toxicity

  1. Cardiac dose-sparing effects of deep-inspiration breath-hold in left breast irradiation : Is IMRT more beneficial than VMAT?

    Science.gov (United States)

    Sakka, Mazen; Kunzelmann, Leonie; Metzger, Martin; Grabenbauer, Gerhard G

    2017-10-01

    Given the reduction in death from breast cancer, as well as improvements in overall survival, adjuvant radiotherapy is considered the standard treatment for breast cancer. However, left-sided breast irradiation was associated with an increased rate of fatal cardiovascular events due to incidental irradiation of the heart. Recently, considerable efforts have been made to minimize cardiac toxicity of left-sided breast irradiation by new treatment methods such as deep-inspiration breath-hold (DIBH) and new radiation techniques, particularly intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). The primary aim of this study was to evaluate the effect of DIBH irradiation on cardiac dose compared with free-breathing (FB) irradiation, while the secondary objective was to compare the advantages of IMRT versus VMAT plans in both the FB and the DIBH position for left-sided breast cancer. In all, 25 consecutive left-sided breast cancer patients underwent CT simulation in the FB and DIBH position. Five patients were excluded with no cardiac displacement following DIBH-CT simulation. The other 20 patients were irradiated in the DIBH position using respiratory gating. Four different treatment plans were generated for each patient, an IMRT and a VMAT plan in the DIBH and in the FB position, respectively. The following parameters were used for plan comparison: dose to the heart, left anterior descending coronary artery (mean dose, maximum dose, D25% and D45%), ipsilateral, contralateral lung (mean dose, D20%, D30%) and contralateral breast (mean dose). The percentage in dose reduction for organs at risk achieved by DIBH for both IMRT and VMAT plans was calculated and compared for each patient by each treatment plan. DIBH irradiation significantly reduced mean dose to the heart and left anterior descending coronary artery (LADCA) using both IMRT (heart -20%; p = 0.0002, LADCA -9%; p = 0.001) and VMAT (heart -23%; p = 0.00003, LADCA -16%; p = 0

  2. Evaluating proton stereotactic body radiotherapy to reduce chest wall dose in the treatment of lung cancer

    International Nuclear Information System (INIS)

    Welsh, James; Amini, Arya; Ciura, Katherine; Nguyen, Ngoc; Palmer, Matt; Soh, Hendrick; Allen, Pamela K.; Paolini, Michael; Liao, Zhongxing; Bluett, Jaques; Mohan, Radhe; Gomez, Daniel; Cox, James D.; Komaki, Ritsuko; Chang, Joe Y.

    2013-01-01

    Stereotactic body radiotherapy (SBRT) can produce excellent local control of several types of solid tumor; however, toxicity to nearby critical structures is a concern. We found previously that in SBRT for lung cancer, the chest wall (CW) volume receiving 20, 30, or 40 Gy (V 20 , V 30 , or V 40 ) was linked with the development of neuropathy. Here we sought to determine whether the dosimetric advantages of protons could produce lower CW doses than traditional photon-based SBRT. We searched an institutional database to identify patients treated with photon SBRT for lung cancer with tumors within 20 was 364.0 cm 3 and 160.0 cm 3 (p 30 was 144.6 cm 3 vs 77.0 cm 3 (p = 0.0012), V 35 was 93.9 cm 3 vs 57.9 cm 3 (p = 0.005), V 40 was 66.5 cm 3 vs 45.4 cm 3 (p = 0.0112), and mean lung dose was 5.9 Gy vs 3.8 Gy (p = 0.0001) for photons and protons, respectively. Coverage of the planning target volume (PTV) was comparable between the 2 sets of plans (96.4% for photons and 97% for protons). From a dosimetric standpoint, proton SBRT can achieve the same coverage of the PTV while significantly reducing the dose to the CW and lung relative to photon SBRT and therefore may be beneficial for the treatment of lesions closer to critical structures

  3. A national survey of the availability of intensity-modulated radiation therapy and stereotactic radiosurgery in Canada

    International Nuclear Information System (INIS)

    AlDuhaiby, Eman Z; Breen, Stephen; Bissonnette, Jean-Pierre; Sharpe, Michael; Mayhew, Linda; Tyldesley, Scott; Wilke, Derek R; Hodgson, David C

    2012-01-01

    The timely and appropriate adoption of new radiation therapy (RT) technologies is a challenge both in terms of providing of optimal patient care and managing health care resources. Relatively little is known regarding the rate at which new RT technologies are adopted in different jurisdictions, and the barriers to implementation of these technologies. Surveys were sent to all radiation oncology department heads in Canada regarding the availability of RT equipment from 2006 to 2010. Data were collected concerning the availability and use of Intensity Modulated Radiation Therapy (IMRT) and stereotactic radiosurgery (SRS), and the obstacles to implementation of these technologies. IMRT was available in 37% of responding centers in 2006, increasing to 87% in 2010. In 2010, 72% of centers reported that IMRT was available for all patients who might benefit, and 37% indicated that they used IMRT for 'virtually all' head and neck patients. SRS availability increased from 26% in 2006 to 42.5% in 2010. Eighty-two percent of centers reported that patients had access to SRS either directly or by referral. The main barriers for IMRT implementation included the need to train or hire treatment planning staff, whereas barriers to SRS implementation mostly included the need to purchase and/or upgrade existing planning software and equipment. The survey showed a growing adoption of IMRT and SRS in Canada, although the latter was available in less than half of responding centers. Barriers to implementation differed for IMRT compared to SRS. Enhancing human resources is an important consideration in the implementation of new RT technologies, due to the multidisciplinary nature of the planning and treatment process

  4. WE-G-BRD-07: Investigation of Distal Lung Atelectasis Following Stereotactic Body Radiation Therapy Using Regional Lung Volume Changes Between Pre- and Post- Treatment CT Scans

    Energy Technology Data Exchange (ETDEWEB)

    Diot, Q; Kavanagh, B; Miften, M [University of Colorado School of Medicine, Aurora, CO (United States)

    2014-06-15

    Purpose: To propose a quantitative method using lung deformations to differentiate between radiation-induced fibrosis and potential airway stenosis with distal atelectasis in patients treated with stereotactic body radiation therapy (SBRT) for lung tumors. Methods: Twenty-four lung patients with large radiation-induced density increases outside the high dose region had their pre- and post-treatment CT scans manually registered. They received SBRT treatments at our institution between 2002 and 2009 in 3 or 5 fractions, to a median total dose of 54Gy (range, 30–60). At least 50 anatomical landmarks inside the lung (airway branches) were paired for the pre- and post-treatment scans to guide the deformable registration of the lung structure, which was then interpolated to the whole lung using splines. Local volume changes between the planning and follow-up scans were calculated using the deformation field Jacobian. Hyperdense regions were classified as atelectatic or fibrotic based on correlations between regional density increases and significant volume contractions compared to the surrounding tissues. Results: Out of 24 patients, only 7 demonstrated a volume contraction that was at least one σ larger than the remaining lung average. Because they did not receive high doses, these shrunk hyperdense regions were likely showing distal atelectasis resulting from radiation-induced airway stenosis rather than conventional fibrosis. On average, the hyperdense regions extended 9.2 cm farther than the GTV contours but not significantly more than 8.6 cm for the other patients (p>0.05), indicating that a large offset between the radiation and hyperdense region centers is not a good surrogate for atelectasis. Conclusion: A method based on the relative comparison of volume changes between different dates was developed to identify potential lung regions experiencing distal atelectasis. Such a tool is essential to study which lung structures need to be avoided to prevent

  5. Impact of low skeletal muscle mass on non-lung cancer mortality after stereotactic body radiotherapy for patients with stage I non-small cell lung cancer.

    Science.gov (United States)

    Matsuo, Yukinori; Mitsuyoshi, Takamasa; Shintani, Takashi; Iizuka, Yusuke; Mizowaki, Takashi

    2018-05-17

    The purpose of the present study was to retrospectively evaluate impact of pre-treatment skeletal muscle mass (SMM) on overall survival and non-lung cancer mortality after stereotactic body radiotherapy (SBRT) for patients with stage I non-small cell lung cancer (NSCLC). One-hundred and eighty-six patients whose abdominal CT before the treatment was available were enrolled into this study. The patients were divided into two groups of SMM according to gender-specific thresholds for unilateral psoas area. Operability was judged by the treating physician or thoracic surgeon after discussion in a multi-disciplinary tumor board. Patients with low SMM tended to be elderly and underweight in body mass index compared with the high SMM. Overall survival in patients with the low SMM tended to be worse than that in the high SMM (41.1% and 55.9% at 5 years, P = 0.115). Cumulative incidence of non-lung cancer death was significantly worse in the low SMM (31.3% at 5 years compared with 9.7% in the high SMM, P = 0.006). Multivariate analysis identified SMM and operability as significant factors for non-lung cancer mortality. Impact of SMM on lung cancer death was not significant. No difference in rate of severe treatment-related toxicity was observed between the SMM groups. Low SMM is a significant risk factor for non-lung cancer death, which might lead to worse overall survival, after SBRT for stage I NSCLC. However, the low SMM does not increase lung cancer death or severe treatment-related toxicity. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Intensity modulated radiotherapy (IMRT in the treatment of children and Adolescents - a single institution's experience and a review of the literature

    Directory of Open Access Journals (Sweden)

    Huber Peter

    2009-09-01

    Full Text Available Abstract Background While IMRT is widely used in treating complex oncological cases in adults, it is not commonly used in pediatric radiation oncology for a variety of reasons. This report evaluates our 9 year experience using stereotactic-guided, inverse planned intensity-modulated radiotherapy (IMRT in children and adolescents in the context of the current literature. Methods Between 1999 and 2008 thirty-one children and adolescents with a mean age of 14.2 years (1.5 - 20.5 were treated with IMRT in our department. This heterogeneous group of patients consisted of 20 different tumor entities, with Ewing's sarcoma being the largest (5 patients, followed by juvenile nasopharyngeal fibroma, esthesioneuroblastoma and rhabdomyosarcoma (3 patients each. In addition a review of the available literature reporting on technology, quality, toxicity, outcome and concerns of IMRT was performed. Results With IMRT individualized dose distributions and excellent sparing of organs at risk were obtained in the most challenging cases. This was achieved at the cost of an increased volume of normal tissue receiving low radiation doses. Local control was achieved in 21 patients. 5 patients died due to progressive distant metastases. No severe acute or chronic toxicity was observed. Conclusion IMRT in the treatment of children and adolescents is feasible and was applied safely within the last 9 years at our institution. Several reports in literature show the excellent possibilities of IMRT in selective sparing of organs at risk and achieving local control. In selected cases the quality of IMRT plans increases the therapeutic ratio and outweighs the risk of potentially increased rates of secondary malignancies by the augmented low dose exposure.

  7. Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung

    International Nuclear Information System (INIS)

    Worm, Esben S.; Hansen, Anders T.; Petersen, Joergen B.; Muren, Ludvig P.; Praestegaard, Lars H.; Hoeyer, Morten

    2010-01-01

    Background. Localisation errors in cone-beam CT (CBCT) guided stereotactic body radiation therapy (SBRT) were evaluated and compared to positioning using the external coordinates of a stereotactic body frame (SBF) alone. Possible correlations to patient- or treatment-specific factors such as body mass index (BMI), planning time, treatment delivery time, and distance between tumour and spinal cord were explored to determine whether they influenced on the benefit of image-guidance. Material and methods. A total of 34 patients received SBRT (3 fractions) for tumours in the liver (15 patients) or the lung (19 patients). Immobilisation and positioning was obtained with a SBF. Pre- and post-treatment CBCT scans were registered with the bony anatomy of the planning CT to find inter- and intrafractional patient positioning errors (PPE). For lung tumour patients, matching was also performed on the tumours to find the tumour positioning errors (TPE) and baseline shifts relative to bony anatomy. Results. The mean inter- and intrafractional 3D vector PPE was 4.5 ± 2.7 mm (average ± SD) and 1.5 ± 0.6 mm, respectively, for the combined group of patients. For lung tumours, the interfractional misalignment was 5.6 ± 1.8 mm. The baseline shift was 3.9 ± 2.0 mm. Intrafractional TPE and baseline shifts were 2.1 ± 0.7 mm and 1.9 ± 0.6 mm, respectively. The magnitude of interfractional baseline shift was closely correlated with the distance between the tumour and the spinal cord. Intrafractional errors were independent of patient BMI, age or gender. Conclusion. Image-guidance reduced setup errors considerably. The study demonstrated the benefit of CBCT-guidance regardless of patient specific factors such as BMI, age or gender. Protection of the spinal cord was facilitated by the correlation between the tumour position relative to the spinal cord and the magnitude of baseline shift.

  8. Pathological vertebral fracture after stereotactic body radiation therapy for lung metastases. Case report and literature review.

    Directory of Open Access Journals (Sweden)

    Rodríguez-Ruiz María

    2012-03-01

    Full Text Available Abstract Background Stereotactic body radiation therapy (SBRT is a radiation technique used in patients with oligometastatic lung disease. Lung and chest wall toxicities have been described in the patients but pathological vertebral fracture is an adverse effect no reported in patients treated with SBRT for lung metastases. Case presentation A 68-year-old woman with the diagnosis of a recurrence of a single lung metastatic nodule of urothelial carcinoma after third line of chemotherapy. The patient received a hypo-fractionated course of SBRT.A 3D-conformal multifield technique was used with six coplanar and one non-coplanar statics beams. A total dose of 48 Gy in three fractions over six days was prescribed to the 95% of the CTV. Ten months after the SBRT procedure, a CT scan showed complete response of the metastatic disease without signs of radiation pneumonitis. However, rib and vertebral bone toxicities were observed with the fracture-collapse of the 7th and 8th vertebral bodies and a fracture of the 7th and 8th left ribs. We report a unique case of pathological vertebral fracture appearing ten months after SBRT for an asymptomatic growing lung metastases of urothelial carcinoma. Conclusion Though SBRT allows for minimization of normal tissue exposure to high radiation doses SBRT tolerance for vertebral bone tissue has been poorly evaluated in patients with lung tumors. Oncologists should be alert to the potential risk of fatal bone toxicity caused by this novel treatment. We recommend BMD testing in all woman over 65 years old with clinical risk factors that could contribute to low BMD. If low BMD is demonstrated, we should carefully restrict the maximum radiation dose in the vertebral body in order to avoid intermediate or low radiation dose to the whole vertebral body.

  9. Dosimetric selection for helical tomotherapy based stereotactic ablative radiotherapy for early-stage non-small cell lung cancer or lung metastases.

    Directory of Open Access Journals (Sweden)

    Alexander Chi

    Full Text Available BACKGROUND: No selection criteria for helical tomotherapy (HT based stereotactic ablative radiotherapy (SABR to treat early stage non-small cell lung cancer (NSCLC or solitary lung metastases has been established. In this study, we investigate the dosimetric selection criteria for HT based SABR delivering 70 Gy in 10 fractions to avoid severe toxicity in the treatment of centrally located lesions when adequate target dose coverage is desired. MATERIALS AND METHODS: 78 HT-SABR plans for solitary lung lesions were created to prescribe 70 Gy in 10 fractions to the planning target volume (PTV. The PTV was set to have ≥95% PTV receiving 70 Gy in each case. The cases for which dose constraints for ≥1 OAR could not be met without compromising the target dose coverage were compared with cases for which all target and OAR dose constraints were met. RESULTS: There were 23 central lesions for which OAR dose constraints could not be met without compromising PTV dose coverage. Comparing to cases for which optimal HT-based SABR plans were generated, they were associated with larger tumor size (5.72±1.96 cm vs. 3.74±1.49 cm, p<0.0001, higher lung dose, increased number of immediately adjacent OARs ( 3.45±1.34 vs. 1.66±0.81, p<0.0001, and shorter distance to the closest OARs (GTV: 0.26±0.22 cm vs. 0.88±0.54 cm, p<0.0001; PTV 0.19±0.18 cm vs. 0.48±0.36 cm, p = 0.0001. CONCLUSION: Delivery of 70 Gy in 10 fractions with HT to meet all the given OAR and PTV dose constraints are most likely when the following parameters are met: lung lesions ≤3.78 cm (11.98 cc, ≤2 immediately adjacent OARs which are ≥0.45 cm from the gross lesion and ≥0.21 cm from the PTV.

  10. Stereotactic body radiotherapy for Stage I lung cancer with chronic obstructive pulmonary disease. Special reference to survival and radiation-induced pneumonitis

    International Nuclear Information System (INIS)

    Inoue, Toshihiko; Shiomi, Hiroya; Oh, Ryoong-Jin

    2015-01-01

    This retrospective study aimed to evaluate radiation-induced pneumonitis (RIP) and a related condition that we define in this report — prolonged minimal RIP (pmRIP) — after stereotactic body radiotherapy (SBRT) for Stage I primary lung cancer in patients with chronic obstructive pulmonary disease (COPD). We assessed 136 Stage I lung cancer patients with COPD who underwent SBRT. Airflow limitation on spirometry was classified into four Global Initiative for Chronic Obstructive Lung Disease (GOLD) grades, with minor modifications: GOLD 1 (mild), GOLD 2 (moderate), GOLD 3 (severe) and GOLD 4 (very severe). On this basis, we defined two subgroups: COPD-free (COPD -) and COPD-positive (COPD +). There was no significant difference in overall survival or cause-specific–survival between these groups. Of the 136 patients, 44 (32%) had pmRIP. Multivariate analysis showed that COPD and the Brinkman index were statistically significant risk factors for the development of pmRIP. COPD and the Brinkman index were predictive factors for pmRIP, although our findings also indicate that SBRT can be tolerated in early lung cancer patients with COPD. (author)

  11. Feasibility of using intensity-modulated radiotherapy to improve lung sparing in treatment planning for distal esophageal cancer

    International Nuclear Information System (INIS)

    Chandra, Anurag; Guerrero, Thomas M.; Liu, H. Helen; Tucker, Susan L.; Liao Zhongxing; Wang Xiaochun; Murshed, Hasan; Bonnen, Mark D.; Garg, Amit K.; Stevens, Craig W.; Chang, Joe Y.; Jeter, Melinda D.; Mohan, Radhe; Cox, James D.; Komaki, Ritsuko

    2005-01-01

    Background and purpose: To evaluate the feasibility whether intensity-modulated radiotherapy (IMRT) can be used to reduce doses to normal lung than three-dimensional conformal radiotherapy (3DCRT) in treating distal esophageal malignancies. Patients and methods: Ten patient cases with cancer of the distal esophagus were selected for a retrospective treatment-planning study. IMRT plans using four, seven, and nine beams (4B, 7B, and 9B) were developed for each patient and compared with the 3DCRT plan used clinically. IMRT and 3DCRT plans were evaluated with respect to PTV coverage and dose-volumes to irradiated normal structures, with statistical comparison made between the two types of plans using the Wilcoxon matched-pair signed-rank test. Results: IMRT plans (4B, 7B, 9B) reduced total lung volume treated above 10 Gy (V 1 ), 20 Gy (V 2 ), mean lung dose (MLD), biological effective volume (V eff ), and lung integral dose (P 1 , 5% for V 2 , and 2.5 Gy for MLD. IMRT improved the PTV heterogeneity (P<0.05), yet conformity was better with 7B-9B IMRT plans. No clinically meaningful differences were observed with respect to the irradiated volumes of spinal cord, heart, liver, or total body integral doses. Conclusions: Dose-volume of exposed normal lung can be reduced with IMRT, though clinical investigations are warranted to assess IMRT treatment outcome of esophagus cancers

  12. Multiple brain metastases irradiation with Eleka Axesse stereotactic system

    Science.gov (United States)

    Filatov, P. V.; Polovnikov, E. S.; Orlov, K. Yu.; Krutko, A. V.; Kirilova, I. A.; Moskalev, A. V.; Filatova, E. V.; Zheravin, A. A.

    2017-09-01

    Brain metastases are one of the factors complicating the treatment of a malignant tumor. Radiation therapy, especially radiosurgery, plays an important role in the modern treatment practice. During 2011-2016, 32 patients (from 29 to 67 years old) with multiple brain metastases underwent the treatment with SRS or SRT in our center. The number of secondary lesions varied from 2 to 11. Eight patients underwent microsurgery resection. Seven patients had recurrence after whole brain radiotherapy. Thirty patient underwent single fraction SRS and two patients with large metastases (bigger than 3 cm) underwent fractionated SRT. The treatment was done with dedicated linear accelerator stereotactic system Elekta Axesse (Elekta AB, Stockholm, Sweden). Different stereotactic fixation devices were used, namely, Leksell G frame, non-invasive HeadFIX frame, and reinforced thermoplastic mask (IMRT perforation). All treatments included a volumetric modulated arc therapy (VMAT) technique and of Inage Guided Radiation Therapy (IGRT) technique. All lesions were treated from a single isocenter, which allowed reducing the treatment time and overall dose to the patient's body. All patients suffered the treatment satisfactorily. No adverse reactions or complications were met in any case during or right after the treatment. Different stereotactic fixation devices and modern treatment techniques allowed creating an optimal, safe and comfortable way for patient treatment. The treatment time was from 15 to 50 minutes. Patient position verification after or during the treatment demonstrated good accuracy for all fixation types and low level of intrafraction motion.

  13. Stereotactic ablative body radiotherapy for non-small-cell lung cancer: setup reproducibility with novel arms-down immobilization.

    Science.gov (United States)

    Moore, Karen; Paterson, Claire; Hicks, Jonathan; Harrow, Stephen; McJury, Mark

    2016-12-01

    A clinical evaluation of the intrafraction and interfraction setup accuracy of a novel thermoplastic mould immobilization device and patient position in early-stage lung cancer being treated with stereotactic radiotherapy at the Beatson West of Scotland Cancer Centre, Glasgow, UK. 35 patients were immobilized in a novel, arms-down position, with a four-point Klarity ™ (Klarity Medical Products, Ohio, US) clear thermoplastic mould fixed to a SinMed (CIVCO Medical solutions, lowa, US) head and neck board. A knee support was also used for patient comfort and support. Pre- and post-treatment kilovoltage cone beam CT (CBCT) images were fused with the planning CT scan to determine intra- and interfraction motion. A total of 175 CBCT scans were analysed in the longitudinal, vertical and lateral directions. The mean intrafraction errors were 0.05 ± 0.77 mm (lateral), 0.44 ± 1.2 mm (superior-inferior) and -1.44 ± 1.35 mm (anteroposterior), respectively. Mean composite three-dimensional displacement vector was 2.14 ± 1.2 mm. Interfraction errors were -0.66 ± 2.35 mm (lateral), -0.13 ± 3.11 mm (superior-inferior) and 0.00 ± 2.94 mm (anteroposterior), with three-dimensional vector 4.08 ± 2.73 mm. Setup accuracy for lung image-guided stereotactic ablative radiotherapy using a unique immobilization device, where patients have arms by their sides, has been shown to be safe and favourably comparable to other published setup data where more complex and cumbersome devices were utilised. There was no arm toxicity reported and low arm doses. Advances in knowledge: We report on the accuracy of a novel patient immobilization device.

  14. Volumetric modulated arc therapy for lung stereotactic radiation therapy can achieve high local control rates.

    Science.gov (United States)

    Yamashita, Hideomi; Haga, Akihiro; Takahashi, Wataru; Takenaka, Ryousuke; Imae, Toshikazu; Takenaka, Shigeharu; Nakagawa, Keiichi

    2014-11-11

    The aim of this study was to report the outcome of primary or metastatic lung cancer patients undergoing volumetric modulated arc therapy for stereotactic body radiation therapy (VMAT-SBRT). From October 2010 to December 2013, consecutive 67 lung cancer patients received single-arc VMAT-SBRT using an Elekta-synergy system. All patients were treated with an abdominal compressor. The gross tumor volumes were contoured on 10 respiratory phases computed tomography (CT) datasets from 4-dimensional (4D) CT and merged into internal target volumes (ITVs). The planning target volume (PTV) margin was isotropically taken as 5 mm. Treatment was performed with a D95 prescription of 50 Gy (43 cases) or 55 Gy (12 cases) in 4 fractions for peripheral tumor or 56 Gy in 7 fractions (12 cases) for central tumor. Among the 67 patients, the median age was 73 years (range, 59-95 years). Of the patients, male was 72% and female 28%. The median Karnofsky performance status was 90-100% in 39 cases (58%) and 80-90% in 20 cases (30%). The median follow-up was 267 days (range, 40-1162 days). Tissue diagnosis was performed in 41 patients (61%). There were T1 primary lung tumor in 42 patients (T1a in 28 patients, T1b in 14 patients), T2 in 6 patients, three T3 in 3 patients, and metastatic lung tumor in 16 patients. The median mean lung dose was 6.87 Gy (range, 2.5-15 Gy). Six patients (9%) developed radiation pneumonitis required by steroid administration. Actuarial local control rate were 100% and 100% at 1 year, 92% and 75% at 2 years, and 92% and 75% at 3 years in primary and metastatic lung cancer, respectively (p =0.59). Overall survival rate was 83% and 84% at 1 year, 76% and 53% at 2 years, and 46% and 20% at 3 years in primary and metastatic lung cancer, respectively (p =0.12). Use of VMAT-based delivery of SBRT in primary in metastatic lung tumors demonstrates high local control rates and low risk of normal tissue complications.

  15. Volumetric modulated arc therapy for lung stereotactic radiation therapy can achieve high local control rates

    International Nuclear Information System (INIS)

    Yamashita, Hideomi; Haga, Akihiro; Takahashi, Wataru; Takenaka, Ryousuke; Imae, Toshikazu; Takenaka, Shigeharu; Nakagawa, Keiichi

    2014-01-01

    The aim of this study was to report the outcome of primary or metastatic lung cancer patients undergoing volumetric modulated arc therapy for stereotactic body radiation therapy (VMAT-SBRT). From October 2010 to December 2013, consecutive 67 lung cancer patients received single-arc VMAT-SBRT using an Elekta-synergy system. All patients were treated with an abdominal compressor. The gross tumor volumes were contoured on 10 respiratory phases computed tomography (CT) datasets from 4-dimensional (4D) CT and merged into internal target volumes (ITVs). The planning target volume (PTV) margin was isotropically taken as 5 mm. Treatment was performed with a D95 prescription of 50 Gy (43 cases) or 55 Gy (12 cases) in 4 fractions for peripheral tumor or 56 Gy in 7 fractions (12 cases) for central tumor. Among the 67 patients, the median age was 73 years (range, 59–95 years). Of the patients, male was 72% and female 28%. The median Karnofsky performance status was 90-100% in 39 cases (58%) and 80-90% in 20 cases (30%). The median follow-up was 267 days (range, 40–1162 days). Tissue diagnosis was performed in 41 patients (61%). There were T1 primary lung tumor in 42 patients (T1a in 28 patients, T1b in 14 patients), T2 in 6 patients, three T3 in 3 patients, and metastatic lung tumor in 16 patients. The median mean lung dose was 6.87 Gy (range, 2.5-15 Gy). Six patients (9%) developed radiation pneumonitis required by steroid administration. Actuarial local control rate were 100% and 100% at 1 year, 92% and 75% at 2 years, and 92% and 75% at 3 years in primary and metastatic lung cancer, respectively (p = 0.59). Overall survival rate was 83% and 84% at 1 year, 76% and 53% at 2 years, and 46% and 20% at 3 years in primary and metastatic lung cancer, respectively (p = 0.12). Use of VMAT-based delivery of SBRT in primary in metastatic lung tumors demonstrates high local control rates and low risk of normal tissue complications

  16. Single-Arc IMRT?

    International Nuclear Information System (INIS)

    Bortfeld, Thomas; Webb, Steve

    2009-01-01

    The idea of delivering intensity-modulated radiation therapy (IMRT) with a multileaf collimator in a continuous dynamic mode during a single rotation of the gantry has recently gained momentum both in research and industry. In this note we investigate the potential of this Single-Arc IMRT technique at a conceptual level. We consider the original theoretical example case from Brahme et al that got the field of IMRT started. Using analytical methods, we derive deliverable intensity 'landscapes' for Single-Arc as well as standard IMRT and Tomotherapy. We find that Tomotherapy provides the greatest flexibility in shaping intensity landscapes and that it allows one to deliver IMRT in a way that comes close to the ideal case in the transverse plane. Single-Arc and standard IMRT make compromises in different areas. Only in relatively simple cases that do not require substantial intensity modulation will Single-Arc be dosimetrically comparable to Tomotherapy. Compared with standard IMRT, Single-Arc could be dosimetrically superior in certain cases if one is willing to accept the spreading of low dose values over large volumes of normal tissue. In terms of treatment planning, Single-Arc poses a more challenging optimization problem than Tomotherapy or standard IMRT. We conclude that Single-Arc holds potential as an efficient IMRT technique especially for relatively simple cases. In very complex cases, Single-Arc may unduly compromise the quality of the dose distribution, if one tries to keep the treatment time below 2 min or so. As with all IMRT techniques, it is important to explore the tradeoff between plan quality and the efficiency of its delivery carefully for each individual case. (note)

  17. Toxic risk of stereotactic body radiotherapy and concurrent helical tomotherapy followed by erlotinib for non-small-cell lung cancer treatment - case report

    International Nuclear Information System (INIS)

    Hsieh, Chen-Hsi; Chen, Chun-Yi; Shueng, Pei-Wei; Chang, Hou-Tai; Lin, Shih-Chiang; Chen, Yu-Jen; Wang, Li-Ying; Hsieh, Yen-Ping; Chen, Chien-An; Chong, Ngot-Swan; Lin, Shoei Long

    2010-01-01

    Stereotactic body radiation therapy (SBRT) applied by helical tomotherapy (HT) is feasible for lung cancer in clinical. Using SBRT concurrently with erlotinib for non-small cell lung cancer (NSCLC) is not reported previously. A 77-year-old man with stage III NSCLC, received erlotinib 150 mg/day, combined with image-guided SBRT via HT. A total tumor dose of 54 Gy/9 fractions was delivered to the tumor bed. The tumor responded dramatically and the combined regimen was well tolerated. After concurrent erlotinib-SBRT, erlotinib was continued as maintenance therapy. The patient developed dyspnea three months after the combined therapy and radiation pneumonitis with interstitial lung disease was suspected. Combination SBRT, HT, and erlotinib therapy provided effective anti-tumor results. Nonetheless, the potential risks of enhanced adverse effects between radiation and erlotinib should be monitored closely, especially when SBRT is part of the regimen

  18. Stereotactic Body Radiation Therapy for Oligometastases to the Lung: A Phase 2 Study

    Energy Technology Data Exchange (ETDEWEB)

    Nuyttens, Joost J., E-mail: j.nuyttens@erasmusmc.nl [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Voort van Zyp, Noëlle C.M.G. van der [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Verhoef, Cornelis [Department of Surgical Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Maat, A. [Department of Cardiothoracic Surgery, Erasmus MC, Rotterdam (Netherlands); Klaveren, Robertus J. van [Department of Pulmonology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Holt, Bronno van der [Clinical Trial Center, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Aerts, Joachim [Department of Pulmonology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Hoogeman, Mischa [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands)

    2015-02-01

    Purpose: To assess, in a phase 2 study, the efficacy and toxicity of stereotactic body radiation therapy for oligometastases to the lung in inoperable patients. Methods and Materials: Patients with lung metastases were included in this study if (1) the primary tumor was controlled; (2) patients were ineligible for or refused surgery and chemotherapy; and (3) patients had 5 or fewer metastatic lesions in no more than 2 organs. Large peripheral tumors were treated with a dose of 60 Gy (3 fractions), small peripheral tumors with 30 Gy (1 fraction), central tumors received 60 Gy (5 fractions), and mediastinal tumors or tumors close to the esophagus received 56 Gy (7 fractions). Results: Thirty patients with 57 metastatic lung tumors from various primary cancers were analyzed. The median follow-up was 36 months (range, 4-60 months). At 2 years, local control for the 11 central tumors was 100%, for the 23 peripheral tumors treated to 60 Gy it was 91%, and for the 23 tumors treated in a single 30-Gy fraction it was 74% (P=.13). This resulted in an overall local control rate at 1 year of 79%, with a 2-sided 80% confidence interval of 67% to 87%. Because the hypothesized value of 70% lies within the confidence interval, we cannot reject the hypothesis that the true local control rate at 1 year is ≤70%, and therefore we did not achieve the goal of the study: an actuarial local control of the treated lung lesions at 1 year of 90%. The 4-year overall survival rate was 38%. Grade 3 acute toxicity occurred in 5 patients. Three patients complained of chronic grade 3 toxicity, including pain, fatigue, and pneumonitis, and 3 patients had rib fractures. Conclusions: The local control was promising, and the 4-year overall survival rate was 38%. The treatment was well tolerated, even for central lesions.

  19. Stereotactic Body Radiation Therapy for Oligometastases to the Lung: A Phase 2 Study

    International Nuclear Information System (INIS)

    Nuyttens, Joost J.; Voort van Zyp, Noëlle C.M.G. van der; Verhoef, Cornelis; Maat, A.; Klaveren, Robertus J. van; Holt, Bronno van der; Aerts, Joachim; Hoogeman, Mischa

    2015-01-01

    Purpose: To assess, in a phase 2 study, the efficacy and toxicity of stereotactic body radiation therapy for oligometastases to the lung in inoperable patients. Methods and Materials: Patients with lung metastases were included in this study if (1) the primary tumor was controlled; (2) patients were ineligible for or refused surgery and chemotherapy; and (3) patients had 5 or fewer metastatic lesions in no more than 2 organs. Large peripheral tumors were treated with a dose of 60 Gy (3 fractions), small peripheral tumors with 30 Gy (1 fraction), central tumors received 60 Gy (5 fractions), and mediastinal tumors or tumors close to the esophagus received 56 Gy (7 fractions). Results: Thirty patients with 57 metastatic lung tumors from various primary cancers were analyzed. The median follow-up was 36 months (range, 4-60 months). At 2 years, local control for the 11 central tumors was 100%, for the 23 peripheral tumors treated to 60 Gy it was 91%, and for the 23 tumors treated in a single 30-Gy fraction it was 74% (P=.13). This resulted in an overall local control rate at 1 year of 79%, with a 2-sided 80% confidence interval of 67% to 87%. Because the hypothesized value of 70% lies within the confidence interval, we cannot reject the hypothesis that the true local control rate at 1 year is ≤70%, and therefore we did not achieve the goal of the study: an actuarial local control of the treated lung lesions at 1 year of 90%. The 4-year overall survival rate was 38%. Grade 3 acute toxicity occurred in 5 patients. Three patients complained of chronic grade 3 toxicity, including pain, fatigue, and pneumonitis, and 3 patients had rib fractures. Conclusions: The local control was promising, and the 4-year overall survival rate was 38%. The treatment was well tolerated, even for central lesions

  20. Stereotactic ablative radiotherapy for small lung tumors with a moderate dose. Favorable results and low toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Duncker-Rohr, V.; Nestle, U. [Universitaetsklinikum Freiburg (Germany); Momm, F. [Ortenau Klinikum Offenburg (Germany)] [and others

    2013-01-15

    Background: Stereotactic ablative body radiotherapy (SBRT, SABR) is being increasingly applied because of its high local efficacy, e.g., for small lung tumors. However, the optimum dosage is still under discussion. Here, we report data on 45 lung lesions [non-small cell lung cancer (NSCLC) or metastases] in 39 patients treated between 2009 and 2010 by SABR. Patients and methods: SABR was performed with total doses of 35 Gy (5 fractions) or 37.5 Gy (3 fractions) prescribed to the 60% isodose line encompassing the planning target volume. Three-monthly follow-up CT scans were supplemented by FDG-PET/CT if clinically indicated. Results: The median follow-up was 17 months. Local progression-free survival rates were 90.5% (all patients), 95.0% (NSCLC), and 81.8% (metastases) at 1 year. At 2 years, the respective local progression-free survival rates were 80.5%, 95.0%, and 59.7%. Overall survival rates were 71.1% (all patients), 65.4% (NSCLC), and 83.3% (metastases) at 1 year. Overall survival rates at 2 years were 52.7%, 45.9%, and 66.7%, respectively. Acute side effects were mild. Conclusion: With the moderate dose schedule used, well-tolerated SABR led to favorable local tumor control as in other published series. Standardization in reporting the dose prescription for SABR is needed to allow comparison of different series in order to determine optimum dosage. (orig.)

  1. Intensity-Modulated Radiotherapy for Locally Advanced Non-Small-Cell Lung Cancer: A Dose-Escalation Planning Study

    International Nuclear Information System (INIS)

    Lievens, Yolande; Nulens, An; Gaber, Mousa Amr; Defraene, Gilles; De Wever, Walter; Stroobants, Sigrid; Van den Heuvel, Frank

    2011-01-01

    Purpose: To evaluate the potential for dose escalation with intensity-modulated radiotherapy (IMRT) in positron emission tomography-based radiotherapy planning for locally advanced non-small-cell lung cancer (LA-NSCLC). Methods and Materials: For 35 LA-NSCLC patients, three-dimensional conformal radiotherapy and IMRT plans were made to a prescription dose (PD) of 66 Gy in 2-Gy fractions. Dose escalation was performed toward the maximal PD using secondary endpoint constraints for the lung, spinal cord, and heart, with de-escalation according to defined esophageal tolerance. Dose calculation was performed using the Eclipse pencil beam algorithm, and all plans were recalculated using a collapsed cone algorithm. The normal tissue complication probabilities were calculated for the lung (Grade 2 pneumonitis) and esophagus (acute toxicity, grade 2 or greater, and late toxicity). Results: IMRT resulted in statistically significant decreases in the mean lung (p <.0001) and maximal spinal cord (p = .002 and 0005) doses, allowing an average increase in the PD of 8.6-14.2 Gy (p ≤.0001). This advantage was lost after de-escalation within the defined esophageal dose limits. The lung normal tissue complication probabilities were significantly lower for IMRT (p <.0001), even after dose escalation. For esophageal toxicity, IMRT significantly decreased the acute NTCP values at the low dose levels (p = .0009 and p <.0001). After maximal dose escalation, late esophageal tolerance became critical (p <.0001), especially when using IMRT, owing to the parallel increases in the esophageal dose and PD. Conclusion: In LA-NSCLC, IMRT offers the potential to significantly escalate the PD, dependent on the lung and spinal cord tolerance. However, parallel increases in the esophageal dose abolished the advantage, even when using collapsed cone algorithms. This is important to consider in the context of concomitant chemoradiotherapy schedules using IMRT.

  2. SU-F-P-23: Setup Uncertainties for the Lung Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Q; Vigneri, P; Madu, C; Potters, L [Northwell Health, New Hyde Park, NY (United States); Cao, Y; Jamshidi, A [Northwell Health, Lake Success, NY (United States); Klein, E [Long Island Jewish Medical Center, Lake Success, NY (United States)

    2016-06-15

    Purpose: The Exactrack X-ray system with six degree-of-freedom (6DoF) adjustment ability can be used for setup of lung stereotactic body radiation therapy. The setup uncertainties from ExacTrack 6D system were analyzed. Methods: The Exactrack X-ray 6D image guided radiotherapy system is used in our clinic. The system is an integration of 2 subsystems: (1): an infrared based optical position system and (2) a radiography kV x-ray imaging system. The infrared system monitors reflective body markers on the patient’s skin to assistant in the initial setup. The radiographic kV devices were used for patient positions verification and adjustment. The position verification was made by fusing the radiographs with the digitally reconstructed radiograph (DRR) images generated by simulation CT images using 6DoF fusion algorithms. Those results were recorded in our system. Gaussian functions were used to fit the data. Results: For 37 lung SBRT patients, the image registration results for the initial setup by using surface markers and for the verifications, were measured. The results were analyzed for 143 treatments. The mean values for the lateral, longitudinal, vertical directions were 0.1, 0.3 and 0.3mm, respectively. The standard deviations for the lateral, longitudinal and vertical directions were 0.62, 0.78 and 0.75mm respectively. The mean values for the rotations around lateral, longitudinal and vertical directions were 0.1, 0.2 and 0.4 degrees respectively, with standard deviations of 0.36, 0.34, and 0.42 degrees. Conclusion: The setup uncertainties for the lung SBRT cases by using Exactrack 6D system were analyzed. The standard deviations of the setup errors were within 1mm for all three directions, and the standard deviations for rotations were within 0.5 degree.

  3. SU-F-P-23: Setup Uncertainties for the Lung Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Zhang, Q; Vigneri, P; Madu, C; Potters, L; Cao, Y; Jamshidi, A; Klein, E

    2016-01-01

    Purpose: The Exactrack X-ray system with six degree-of-freedom (6DoF) adjustment ability can be used for setup of lung stereotactic body radiation therapy. The setup uncertainties from ExacTrack 6D system were analyzed. Methods: The Exactrack X-ray 6D image guided radiotherapy system is used in our clinic. The system is an integration of 2 subsystems: (1): an infrared based optical position system and (2) a radiography kV x-ray imaging system. The infrared system monitors reflective body markers on the patient’s skin to assistant in the initial setup. The radiographic kV devices were used for patient positions verification and adjustment. The position verification was made by fusing the radiographs with the digitally reconstructed radiograph (DRR) images generated by simulation CT images using 6DoF fusion algorithms. Those results were recorded in our system. Gaussian functions were used to fit the data. Results: For 37 lung SBRT patients, the image registration results for the initial setup by using surface markers and for the verifications, were measured. The results were analyzed for 143 treatments. The mean values for the lateral, longitudinal, vertical directions were 0.1, 0.3 and 0.3mm, respectively. The standard deviations for the lateral, longitudinal and vertical directions were 0.62, 0.78 and 0.75mm respectively. The mean values for the rotations around lateral, longitudinal and vertical directions were 0.1, 0.2 and 0.4 degrees respectively, with standard deviations of 0.36, 0.34, and 0.42 degrees. Conclusion: The setup uncertainties for the lung SBRT cases by using Exactrack 6D system were analyzed. The standard deviations of the setup errors were within 1mm for all three directions, and the standard deviations for rotations were within 0.5 degree.

  4. Pareto front analysis of 6 and 15 MV dynamic IMRT for lung cancer using pencil beam, AAA and Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Ottosson, R O; Karlsson, A; Behrens, C F, E-mail: riolot01@heh.regionh.d [Department of Oncology (R), Division of Radiophysics (52AA), Copenhagen University Hospital Herlev, Herlev Ringvej 75, DK-2730 Herlev (Denmark)

    2010-08-21

    The pencil beam dose calculation method is frequently used in modern radiation therapy treatment planning regardless of the fact that it is documented inaccurately for cases involving large density variations. The inaccuracies are larger for higher beam energies. As a result, low energy beams are conventionally used for lung treatments. The aim of this study was to analyze the advantages and disadvantages of dynamic IMRT treatment planning for high and low photon energy in order to assess if deviating from the conventional low energy approach could be favorable in some cases. Furthermore, the influence of motion on the dose distribution was investigated. Four non-small cell lung cancer cases were selected for this study. Inverse planning was conducted using Varian Eclipse. A total number of 31 dynamic IMRT plans, distributed amongst the four cases, were created ranging from PTV conformity weighted to normal tissue sparing weighted. All optimized treatment plans were calculated using three different calculation algorithms (PBC, AAA and MC). In order to study the influence of motion, two virtual lung phantoms were created. The idea was to mimic two different situations: one where the GTV is located centrally in the PTV and another where the GTV was close to the edge of the PTV. PBC is in poor agreement with MC and AAA for all cases and treatment plans. AAA overestimates the dose, compared to MC. This effect is more pronounced for 15 than 6 MV. AAA and MC both predict similar perturbations in dose distributions when moving the GTV to the edge of the PTV. PBC, however, predicts results contradicting those of AAA and MC. This study shows that PB-based dose calculation algorithms are clinically insufficient for patient geometries involving large density inhomogeneities. AAA is in much better agreement with MC, but even a small overestimation of the dose level by the algorithm might lead to a large part of the PTV being underdosed. It is advisable to use low energy as a

  5. Pareto front analysis of 6 and 15 MV dynamic IMRT for lung cancer using pencil beam, AAA and Monte Carlo.

    Science.gov (United States)

    Ottosson, R O; Karlsson, A; Behrens, C F

    2010-08-21

    The pencil beam dose calculation method is frequently used in modern radiation therapy treatment planning regardless of the fact that it is documented inaccurately for cases involving large density variations. The inaccuracies are larger for higher beam energies. As a result, low energy beams are conventionally used for lung treatments. The aim of this study was to analyze the advantages and disadvantages of dynamic IMRT treatment planning for high and low photon energy in order to assess if deviating from the conventional low energy approach could be favorable in some cases. Furthermore, the influence of motion on the dose distribution was investigated. Four non-small cell lung cancer cases were selected for this study. Inverse planning was conducted using Varian Eclipse. A total number of 31 dynamic IMRT plans, distributed amongst the four cases, were created ranging from PTV conformity weighted to normal tissue sparing weighted. All optimized treatment plans were calculated using three different calculation algorithms (PBC, AAA and MC). In order to study the influence of motion, two virtual lung phantoms were created. The idea was to mimic two different situations: one where the GTV is located centrally in the PTV and another where the GTV was close to the edge of the PTV. PBC is in poor agreement with MC and AAA for all cases and treatment plans. AAA overestimates the dose, compared to MC. This effect is more pronounced for 15 than 6 MV. AAA and MC both predict similar perturbations in dose distributions when moving the GTV to the edge of the PTV. PBC, however, predicts results contradicting those of AAA and MC. This study shows that PB-based dose calculation algorithms are clinically insufficient for patient geometries involving large density inhomogeneities. AAA is in much better agreement with MC, but even a small overestimation of the dose level by the algorithm might lead to a large part of the PTV being underdosed. It is advisable to use low energy as a

  6. Pareto front analysis of 6 and 15 MV dynamic IMRT for lung cancer using pencil beam, AAA and Monte Carlo

    International Nuclear Information System (INIS)

    Ottosson, R O; Karlsson, A; Behrens, C F

    2010-01-01

    The pencil beam dose calculation method is frequently used in modern radiation therapy treatment planning regardless of the fact that it is documented inaccurately for cases involving large density variations. The inaccuracies are larger for higher beam energies. As a result, low energy beams are conventionally used for lung treatments. The aim of this study was to analyze the advantages and disadvantages of dynamic IMRT treatment planning for high and low photon energy in order to assess if deviating from the conventional low energy approach could be favorable in some cases. Furthermore, the influence of motion on the dose distribution was investigated. Four non-small cell lung cancer cases were selected for this study. Inverse planning was conducted using Varian Eclipse. A total number of 31 dynamic IMRT plans, distributed amongst the four cases, were created ranging from PTV conformity weighted to normal tissue sparing weighted. All optimized treatment plans were calculated using three different calculation algorithms (PBC, AAA and MC). In order to study the influence of motion, two virtual lung phantoms were created. The idea was to mimic two different situations: one where the GTV is located centrally in the PTV and another where the GTV was close to the edge of the PTV. PBC is in poor agreement with MC and AAA for all cases and treatment plans. AAA overestimates the dose, compared to MC. This effect is more pronounced for 15 than 6 MV. AAA and MC both predict similar perturbations in dose distributions when moving the GTV to the edge of the PTV. PBC, however, predicts results contradicting those of AAA and MC. This study shows that PB-based dose calculation algorithms are clinically insufficient for patient geometries involving large density inhomogeneities. AAA is in much better agreement with MC, but even a small overestimation of the dose level by the algorithm might lead to a large part of the PTV being underdosed. It is advisable to use low energy as a

  7. Intrafraction Variation of Mean Tumor Position During Image-Guided Hypofractionated Stereotactic Body Radiotherapy for Lung Cancer

    International Nuclear Information System (INIS)

    Shah, Chirag; Grills, Inga S.; Kestin, Larry L.; McGrath, Samuel; Ye Hong; Martin, Shannon K.; Yan Di

    2012-01-01

    Purpose: Prolonged delivery times during daily cone-beam computed tomography (CBCT)-guided lung stereotactic body radiotherapy (SBRT) introduce concerns regarding intrafraction variation (IFV) of the mean target position (MTP). The purpose of this study was to evaluate the magnitude of the IFV-MTP and to assess target margins required to compensate for IFV and postonline CBCT correction residuals. Patient, treatment, and tumor characteristics were analyzed with respect to their impact on IFV-MTP. Methods and Materials: A total of 126 patients with 140 tumors underwent 659 fractions of lung SBRT. Dose prescribed was 48 or 60 Gy in 12 Gy fractions. Translational target position correction of the MTP was performed via onboard CBCT. IFV-MTP was measured as the difference in MTP between the postcorrection CBCT and the posttreatment CBCT excluding residual error. Results: IFV-MTP was 0.2 ± 1.8 mm, 0.1 ± 1.9 mm, and 0.01 ± 1.5 mm in the craniocaudal, anteroposterior, and mediolateral dimensions and the IFV-MTP vector was 2.3 ± 2.1 mm. Treatment time and excursion were found to be significant predictors of IFV-MTP. An IFV-MTP vector greater than 2 and 5 mm was seen in 40.8% and 7.2% of fractions, respectively. IFV-MTP greater than 2 mm was seen in heavier patients with larger excursions and longer treatment times. Significant differences in IFV-MTP were seen between immobilization devices. The stereotactic frame immobilization device was found to be significantly less likely to have an IFV-MTP vector greater than 2 mm compared with the alpha cradle, BodyFIX, and hybrid immobilization devices. Conclusions: Treatment time and respiratory excursion are significantly associated with IFV-MTP. Significant differences in IFV-MTP were found between immobilization devices. Target margins for IFV-MTP plus post-correction residuals are dependent on immobilization device with 5-mm uniform margins being acceptable for the frame immobilization device.

  8. The Comparison of Stereotactic Body Radiation Therapy (SBRT andIntensity Modulated Radiation Therapy (IMRT for prostate cancer byNCCN risk groups

    Directory of Open Access Journals (Sweden)

    Anthony Ricco

    2016-08-01

    Full Text Available OBJECTIVES: The primary objective of this study is to compare freedom from biochemical failure (FFBF between SBRT and IMRT for patients with organ confined prostate cancer treated between 2007 through 2012 utilizing the 2015 National Comprehensive Cancer Network (NCCN risk stratification guidelines. A secondary objective is to compare our updated toxicity at last follow up compared to pretreatment with respect to bowel, bladder, sexual functioning, and need for invasive procedures between the two groups.METHODS: We retrospectively reviewed 270 consecutive men treated with either SBRT (n=150 or IMRT (120 at a community hospital with two distinct radiation departments and referral patterns. Charts were reviewed for pretreatment and treatment factors including race, age, clinical T stage, initial PSA, Gleason score, use of androgen deprivation therapy (ADT, treatment with SBRT vs. IMRT as well as stratification by 2015 NCCN guidelines. Kaplan Meier (KM methodology was used to estimate freedom from biochemical failure, with statistical comparisons accomplished using log rank tests. Multivariable Cox proportional hazard modeling was used to establish independent factors prognostic of biochemical failure. Descriptive statistics were used to describe toxicity graded by a modified RTOG late radiation morbidity scoring system. RESULTS: Significant prognostic factors in univariate analysis for FFBF included NCCN risk groups (p=0.0032, grade (p=0.019, and PSA (p=0.008. There was no significant difference in FFBF between SBRT vs. IMRT (p=0.46 with 6 year actuarial FFBF of 91.9% for SBRT and 88.9% for IMRT. Multivariable analysis revealed only the NCCN risk stratification to be significant predictor for FFBF (p=0.04. 4 year actuarial FFBF by NCCN risk stratification was 100% very low risk, 100% low risk, 96.5% intermediate risk, 94.5% high risk, and 72.7% very high risk. There were no grade 3 gastrointestinal (GI or genitourinary (GU toxicities for either

  9. The management of tumor motions in the stereotactic irradiation to lung cancer under the use of Abches to control active breathing

    Energy Technology Data Exchange (ETDEWEB)

    Tarohda, Tohru I.; Ishiguro, Mitsuru; Hasegawa, Kouhei; Kohda, Yukihiko; Onishi, Hiroaki; Aoki, Tetsuya; Takanaka, Tsuyoshi [Department of Radiology, Asanogawa General Hospital, 83 Kosaka-naka, Kanazawa 920-8621 (Japan); Department of Neurosurgery, Asanogawa General Hospital, 83 Kosaka-naka, Kanazawa 920-8621 (Japan); Naruwa Clinic, 1-16-6 Naruwa, Kanazawa 920-0818 (Japan); Department of Radiation Therapy, Kanazawa University, 13-1 Takaramachi, Kanazawa 920-8641 (Japan)

    2011-07-15

    Purpose: Breathing control is crucial to ensuring the accuracy of stereotactic irradiation for lung cancer. This study monitored respiration in patients with inoperable nonsmall-cell lung cancer using a respiration-monitoring apparatus, Abches, and investigated the reproducibility of tumor position in these patients. Methods: Subjects comprised 32 patients with nonsmall-cell lung cancer who were administered stereotactic radiotherapy under breath-holding conditions monitored by Abches. Computed tomography (CT) was performed under breath-holding conditions using Abches (Abches scan) for treatment planning. A free-breathing scan was performed to determine the range of tumor motions in a given position. After the free-breathing scan, Abches scan was repeated and the tumor position thus defined was taken as the intrafraction tumor position. Abches scan was also performed just before treatment, and the tumor position thus defined was taken as the interfraction tumor position. To calculate the errors, tumor positions were compared based on Abches scan for the initial treatment plan. The error in tumor position was measured using the BrainSCAN treatment-planning device, then compared for each lung lobe. Results: Displacements in tumor position were calculated in three dimensions (i.e., superior-inferior (S-I), left-right (L-R), and anterior-posterior (A-P) dimensions) and recorded as absolute values. For the whole lung, average intrafraction tumor displacement was 1.1 mm (L-R), 1.9 mm (A-P), and 2.0 mm (S-I); the average interfraction tumor displacement was 1.1 mm (L-R), 2.1 mm (A-P), and 2.0 mm (S-I); and the average free-breathing tumor displacement was 2.3 mm (L-R), 3.5 mm (A-P), and 7.9 mm (S-I). The difference between using Abches and free breathing could be reduced from approximately 20 mm at the maximum to approximately 3 mm in the S-I direction for both intrafraction and interfraction positions in the lower lobe. In addition, maximum intrafraction tumor

  10. Study of the absorbed dose in small fields with absence of lateral electronic balance in stereotactic radiosurgery and radiotherapy with modulated intensity

    International Nuclear Information System (INIS)

    Vargas V, M. X.

    2013-01-01

    In this thesis we develop and experimental and theoretical study, using semi analytical techniques of the physical dosimetry for small and nonstandard fields for stereotactic radiosurgery (Srs) and intensity modulated radiation therapy (IMRT), with high energy photon beams from a BrainLAB system with cones at Instituto del Cancer SOLCA (Ecuador) and a Tomo Therapy Hi-Art system at Centro Oncologico de Chihuahua (Mexico). (Author)

  11. Superiority of conventional intensity-modulated radiotherapy over helical tomotherapy in locally advanced non-small cell lung cancer. A comparative plan analysis

    Energy Technology Data Exchange (ETDEWEB)

    Song, C. [National Cancer Center, Research Institute and Hospital, Goyang (Korea, Republic of). Proton Therapy Center; Seoul National Univ. College of Medicine (Korea, Republic of). Dept. of Radiation Oncology; Pyo, H.; Kim, J. [Sungkyunkwan Univ. School of Medicine, Samsung Medical Center, Seoul (Korea, Republic of). Dept. of Radiation Oncology; Lim, Y.K.; Kim, D.W.; Cho, K.H. [National Cancer Center, Research Institute and Hospital, Goyang (Korea, Republic of). Proton Therapy Center; Kim, W.C. [Inha Univ. School of Medicine, Incheon (Korea, Republic of). Dept. of Radiation Oncology; Kim, H.J. [Seoul National Univ. College of Medicine (Korea, Republic of). Dept. of Radiation Oncology

    2012-10-15

    Purpose: To compare helical tomotherapy (HT) and conventional intensity-modulated radiotherapy (IMRT) using a variety of dosimetric and radiobiologic indexes in patients with locally advanced non-small cell lung cancer (LA-NSCLC). Patients and methods: A total of 20 patients with LA-NSCLC were enrolled. IMRT plans with 4-6 coplanar beams and HT plans were generated for each patient. Dose distributions and dosimetric indexes for the tumors and critical structures were computed for both plans and compared. Results: Both modalities created highly conformal plans. They did not differ in the volumes of lung exposed to > 20 Gy of radiation. The average mean lung dose, volume receiving {>=} 30 Gy, and volume receiving {>=} 10 Gy in HT planning were 18.3 Gy, 18.5%, and 57.1%, respectively, compared to 19.4 Gy, 25.4%, and 48.9%, respectively, with IMRT (p = 0.004, p < 0.001, and p < 0.001). The differences between HT and IMRT in lung volume receiving {>=} 10-20 Gy increased significantly as the planning target volume (PTV) increased. For 6 patients who had PTV greater than 700 cm{sup 3}, IMRT was superior to HT for 5 patients in terms of lung volume receiving {>=} 5-20 Gy. The integral dose to the entire thorax in HT plans was significantly higher than in IMRT plans. Conclusion: HT gave significantly better control of mean lung dose and volume receiving {>=} 30-40 Gy, whereas IMRT provided better control of the lung volume receiving {>=} 5-15 Gy and the integral dose to entire thorax. In most patients with PTV greater than 700 cm{sup 3}, IMRT was superior to HT in terms of lung volume receiving {>=} 5-20 Gy. It is therefore advised that caution should be exercised when planning LA-NSCLC using HT. (orig.)

  12. Preserving Functional Lung Using Perfusion Imaging and Intensity-Modulated Radiation Therapy for Advanced-Stage Non-Small Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shioyama, Yoshiyuki; Jang, Si Young; Liu, H. Helen; Guerrero, Thomas; Wang, Xuanmin; Gayed, Isis W.; Erwin, William D.; Liao, Zhongxing; Chang, Joe Y.; Jeter, Melenda; Yaremko, Brian P.; Borghero, Yerko O.; Cox, James D.; Komaki, Ritsuko; Mohan, Radhe

    2007-01-01

    Purpose: To assess quantitatively the impact of incorporating functional lung imaging into intensity-modulated radiation therapy planning for locally advanced non-small cell lung cancer (NSCLC). Methods and Materials: Sixteen patients with advanced-stage NSCLC who underwent radiotherapy were included in this study. Before radiotherapy, each patient underwent lung perfusion imaging with single-photon-emission computed tomography and X-ray computed tomography (SPECT-CT). The SPECT-CT was registered with simulation CT and was used to segment the 50- and 90-percentile hyperperfusion lung (F50 lung and F90 lung). Two IMRT plans were designed and compared in each patient: an anatomic plan using simulation CT alone and a functional plan using SPECT-CT in addition to the simulation CT. Dosimetric parameters of the two types of plans were compared in terms of tumor coverage and avoidance of normal tissues. Results: In incorporating perfusion information in IMRT planning, the median reductions in the mean doses to the F50 and F90 lung in the functional plan were 2.2 and 4.2 Gy, respectively, compared with those in the anatomic plans. The median reductions in the percentage of volume irradiated with >5 Gy, >10 Gy, and >20 Gy in the functional plans were 7.1%, 6.0%, and 5.1%, respectively, for F50 lung, and 11.7%, 12.0%, and 6.8%, respectively, for F90 lung. A greater degree of sparing of the functional lung was achieved for patients with large perfusion defects compared with those with relatively uniform perfusion distribution. Conclusion: Function-guided IMRT planning appears to be effective in preserving functional lung in locally advanced-stage NSCLC patients

  13. Functional Image-Guided Radiotherapy Planning in Respiratory-Gated Intensity-Modulated Radiotherapy for Lung Cancer Patients With Chronic Obstructive Pulmonary Disease

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Tomoki, E-mail: tkkimura@hiroshima-u.ac.jp [Department of Radiation Oncology, Hiroshima University, Graduate School of Biomedical Sciences, Hiroshima City (Japan); Nishibuchi, Ikuno; Murakami, Yuji; Kenjo, Masahiro; Kaneyasu, Yuko; Nagata, Yasushi [Department of Radiation Oncology, Hiroshima University, Graduate School of Biomedical Sciences, Hiroshima City (Japan)

    2012-03-15

    Purpose: To investigate the incorporation of functional lung image-derived low attenuation area (LAA) based on four-dimensional computed tomography (4D-CT) into respiratory-gated intensity-modulated radiotherapy (IMRT) or volumetric modulated arc therapy (VMAT) in treatment planning for lung cancer patients with chronic obstructive pulmonary disease (COPD). Methods and Materials: Eight lung cancer patients with COPD were the subjects of this study. LAA was generated from 4D-CT data sets according to CT values of less than than -860 Hounsfield units (HU) as a threshold. The functional lung image was defined as the area where LAA was excluded from the image of the total lung. Two respiratory-gated radiotherapy plans (70 Gy/35 fractions) were designed and compared in each patient as follows: Plan A was an anatomical IMRT or VMAT plan based on the total lung; Plan F was a functional IMRT or VMAT plan based on the functional lung. Dosimetric parameters (percentage of total lung volume irradiated with {>=}20 Gy [V20], and mean dose of total lung [MLD]) of the two plans were compared. Results: V20 was lower in Plan F than in Plan A (mean 1.5%, p = 0.025 in IMRT, mean 1.6%, p = 0.044 in VMAT) achieved by a reduction in MLD (mean 0.23 Gy, p = 0.083 in IMRT, mean 0.5 Gy, p = 0.042 in VMAT). No differences were noted in target volume coverage and organ-at-risk doses. Conclusions: Functional IGRT planning based on LAA in respiratory-guided IMRT or VMAT appears to be effective in preserving a functional lung in lung cancer patients with COPD.

  14. Toxic risk of stereotactic body radiotherapy and concurrent helical tomotherapy followed by erlotinib for non-small-cell lung cancer treatment - case report

    Directory of Open Access Journals (Sweden)

    Chen Chien-An

    2010-12-01

    Full Text Available Abstract Background Stereotactic body radiation therapy (SBRT applied by helical tomotherapy (HT is feasible for lung cancer in clinical. Using SBRT concurrently with erlotinib for non-small cell lung cancer (NSCLC is not reported previously. Case Presentation A 77-year-old man with stage III NSCLC, received erlotinib 150 mg/day, combined with image-guided SBRT via HT. A total tumor dose of 54 Gy/9 fractions was delivered to the tumor bed. The tumor responded dramatically and the combined regimen was well tolerated. After concurrent erlotinib-SBRT, erlotinib was continued as maintenance therapy. The patient developed dyspnea three months after the combined therapy and radiation pneumonitis with interstitial lung disease was suspected. Conclusions Combination SBRT, HT, and erlotinib therapy provided effective anti-tumor results. Nonetheless, the potential risks of enhanced adverse effects between radiation and erlotinib should be monitored closely, especially when SBRT is part of the regimen.

  15. Whole brain radiotherapy with adjuvant or concomitant boost in brain metastasis: dosimetric comparison between helical and volumetric IMRT technique.

    Science.gov (United States)

    Borghetti, Paolo; Pedretti, Sara; Spiazzi, Luigi; Avitabile, Rossella; Urpis, Mauro; Foscarini, Federica; Tesini, Giulia; Trevisan, Francesca; Ghirardelli, Paolo; Pandini, Sara Angela; Triggiani, Luca; Magrini, Stefano Maria; Buglione, Michela

    2016-04-19

    To compare and evaluate the possible advantages related to the use of VMAT and helical IMRT and two different modalities of boost delivering, adjuvant stereotactic boost (SRS) or simultaneous integrated boost (SIB), in the treatment of brain metastasis (BM) in RPA classes I-II patients. Ten patients were treated with helical IMRT, 5 of them with SRS after whole brain radiotherapy (WBRT) and 5 with SIB. MRI co-registration with planning CT was mandatory and prescribed doses were 30 Gy in 10 fractions (fr) for WBRT and 15Gy/1fr or 45Gy/10fr in SRS or SIB, respectively. For each patient, 4 "treatment plans" (VMAT SRS and SIB, helical IMRT SRS and SIB) were calculated and accepted if PTV boost was included in 95 % isodose and dose constraints of the main organs at risk were respected without major deviations. Homogeneity Index (HI), Conformal Index (CI) and Conformal Number (CN) were considered to compare the different plans. Moreover, time of treatment delivery was calculated and considered in the analysis. Volume of brain metastasis ranged between 1.43 and 51.01 cc (mean 12.89 ± 6.37 ml) and 3 patients had double lesions. V95% resulted over 95 % in the average for each kind of technique, but the "target coverage" was inadequate for VMAT planning with two sites. The HI resulted close to the ideal value of zero in all cases; VMAT-SIB, VMAT-SRS, Helical IMRT-SIB and Helical IMRT-SRS showed mean CI of 2.15, 2.10, 2.44 and 1.66, respectively (optimal range: 1.5-2.0). Helical IMRT-SRS was related to the best and reliable finding of CN (0.66). The mean of treatment time was 210 s, 467 s, 440 s, 1598 s, respectively, for VMAT-SIB, VMAT-SRS, Helical IMRT-SIB and Helical IMRT-SRS. This dosimetric comparison show that helical IMRT obtain better target coverage and respect of CI and CN; VMAT could be acceptable in solitary metastasis. SIB modality can be considered as a good choice for clinical and logistic compliance; literature's preliminary data are confirming also a

  16. Acute exacerbation of subclinical idiopathic pulmonary fibrosis triggered by hypofractionated stereotactic body radiotherapy in a patient with primary lung cancer and slightly focal honeycombing

    International Nuclear Information System (INIS)

    Takeda, Atsuya; Sanuki, Naoko; Enomoto, Tatsuji; Takeda, Toshiaki; Kunieda, Etsuo; Nakajima, Takeshi; Sayama, Koichi

    2008-01-01

    Hypofractionated stereotactic body radiotherapy (SBRT) for pulmonary lesions provides a high local control rate, allows completely painless ambulatory treatment, and is not associated with adverse reactions in most cases. Here we report a 70-year-old lung cancer patient with slight focal pulmonary honeycombing in whom subclinical idiopathic pulmonary fibrosis was exacerbated by SBRT. This experience has important implications for the development of selection criteria prior to SBRT for pulmonary lesions. For SBRT candidates with lung tumors, attention must be paid to the presence of co-morbid interstitial pneumonia even if findings are minimal. Such patients must be informed of potential risks, and careful decision-making must take place when SBRT is being considered. (author)

  17. Computer-aided beam arrangement based on similar cases in radiation treatment-planning databases for stereotactic lung radiation therapy

    International Nuclear Information System (INIS)

    Magome, Taiki; Shioyama, Yoshiyuki; Arimura, Hidetaka

    2013-01-01

    The purpose of this study was to develop a computer-aided method for determination of beam arrangements based on similar cases in a radiotherapy treatment-planning database for stereotactic lung radiation therapy. Similar-case-based beam arrangements were automatically determined based on the following two steps. First, the five most similar cases were searched, based on geometrical features related to the location, size and shape of the planning target volume, lung and spinal cord. Second, five beam arrangements of an objective case were automatically determined by registering five similar cases with the objective case, with respect to lung regions, by means of a linear registration technique. For evaluation of the beam arrangements five treatment plans were manually created by applying the beam arrangements determined in the second step to the objective case. The most usable beam arrangement was selected by sorting the five treatment plans based on eight plan evaluation indices, including the D95, mean lung dose and spinal cord maximum dose. We applied the proposed method to 10 test cases, by using an RTP database of 81 cases with lung cancer, and compared the eight plan evaluation indices between the original treatment plan and the corresponding most usable similar-case-based treatment plan. As a result, the proposed method may provide usable beam arrangements, which have no statistically significant differences from the original beam arrangements (P>0.05) in terms of the eight plan evaluation indices. Therefore, the proposed method could be employed as an educational tool for less experienced treatment planners. (author)

  18. Inverse planning IMRT

    International Nuclear Information System (INIS)

    Rosenwald, J.-C.

    2008-01-01

    The lecture addressed the following topics: Optimizing radiotherapy dose distribution; IMRT contributes to optimization of energy deposition; Inverse vs direct planning; Main steps of IMRT; Background of inverse planning; General principle of inverse planning; The 3 main components of IMRT inverse planning; The simplest cost function (deviation from prescribed dose); The driving variable : the beamlet intensity; Minimizing a 'cost function' (or 'objective function') - the walker (or skier) analogy; Application to IMRT optimization (the gradient method); The gradient method - discussion; The simulated annealing method; The optimization criteria - discussion; Hard and soft constraints; Dose volume constraints; Typical user interface for definition of optimization criteria; Biological constraints (Equivalent Uniform Dose); The result of the optimization process; Semi-automatic solutions for IMRT; Generalisation of the optimization problem; Driving and driven variables used in RT optimization; Towards multi-criteria optimization; and Conclusions for the optimization phase. (P.A.)

  19. TH-A-9A-02: BEST IN PHYSICS (THERAPY) - 4D IMRT Planning Using Highly- Parallelizable Particle Swarm Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Modiri, A; Gu, X; Sawant, A [UT Southwestern Medical Center, Dallas, TX (United States)

    2014-06-15

    Purpose: We present a particle swarm optimization (PSO)-based 4D IMRT planning technique designed for dynamic MLC tracking delivery to lung tumors. The key idea is to utilize the temporal dimension as an additional degree of freedom rather than a constraint in order to achieve improved sparing of organs at risk (OARs). Methods: The target and normal structures were manually contoured on each of the ten phases of a 4DCT scan acquired from a lung SBRT patient who exhibited 1.5cm tumor motion despite the use of abdominal compression. Corresponding ten IMRT plans were generated using the Eclipse treatment planning system. These plans served as initial guess solutions for the PSO algorithm. Fluence weights were optimized over the entire solution space i.e., 10 phases × 12 beams × 166 control points. The size of the solution space motivated our choice of PSO, which is a highly parallelizable stochastic global optimization technique that is well-suited for such large problems. A summed fluence map was created using an in-house B-spline deformable image registration. Each plan was compared with a corresponding, internal target volume (ITV)-based IMRT plan. Results: The PSO 4D IMRT plan yielded comparable PTV coverage and significantly higher dose—sparing for parallel and serial OARs compared to the ITV-based plan. The dose-sparing achieved via PSO-4DIMRT was: lung Dmean = 28%; lung V20 = 90%; spinal cord Dmax = 23%; esophagus Dmax = 31%; heart Dmax = 51%; heart Dmean = 64%. Conclusion: Truly 4D IMRT that uses the temporal dimension as an additional degree of freedom can achieve significant dose sparing of serial and parallel OARs. Given the large solution space, PSO represents an attractive, parallelizable tool to achieve globally optimal solutions for such problems. This work was supported through funding from the National Institutes of Health and Varian Medical Systems. Amit Sawant has research funding from Varian Medical Systems, VisionRT Ltd. and Elekta.

  20. GPU-Monte Carlo based fast IMRT plan optimization

    Directory of Open Access Journals (Sweden)

    Yongbao Li

    2014-03-01

    Full Text Available Purpose: Intensity-modulated radiation treatment (IMRT plan optimization needs pre-calculated beamlet dose distribution. Pencil-beam or superposition/convolution type algorithms are typically used because of high computation speed. However, inaccurate beamlet dose distributions, particularly in cases with high levels of inhomogeneity, may mislead optimization, hindering the resulting plan quality. It is desire to use Monte Carlo (MC methods for beamlet dose calculations. Yet, the long computational time from repeated dose calculations for a number of beamlets prevents this application. It is our objective to integrate a GPU-based MC dose engine in lung IMRT optimization using a novel two-steps workflow.Methods: A GPU-based MC code gDPM is used. Each particle is tagged with an index of a beamlet where the source particle is from. Deposit dose are stored separately for beamlets based on the index. Due to limited GPU memory size, a pyramid space is allocated for each beamlet, and dose outside the space is neglected. A two-steps optimization workflow is proposed for fast MC-based optimization. At first step, a rough dose calculation is conducted with only a few number of particle per beamlet. Plan optimization is followed to get an approximated fluence map. In the second step, more accurate beamlet doses are calculated, where sampled number of particles for a beamlet is proportional to the intensity determined previously. A second-round optimization is conducted, yielding the final result.Results: For a lung case with 5317 beamlets, 105 particles per beamlet in the first round, and 108 particles per beam in the second round are enough to get a good plan quality. The total simulation time is 96.4 sec.Conclusion: A fast GPU-based MC dose calculation method along with a novel two-step optimization workflow are developed. The high efficiency allows the use of MC for IMRT optimizations.--------------------------------Cite this article as: Li Y, Tian Z

  1. Using gEUD based plan analysis method to evaluate proton vs. photon plans for lung cancer radiation therapy.

    Science.gov (United States)

    Xiao, Zhiyan; Zou, Wei J; Chen, Ting; Yue, Ning J; Jabbour, Salma K; Parikh, Rahul; Zhang, Miao

    2018-03-01

    The goal of this study was to exam the efficacy of current DVH based clinical guidelines draw from photon experience for lung cancer radiation therapy on proton therapy. Comparison proton plans and IMRT plans were generated for 10 lung patients treated in our proton facility. A gEUD based plan evaluation method was developed for plan evaluation. This evaluation method used normal lung gEUD(a) curve in which the model parameter "a" was sampled from the literature reported value. For all patients, the proton plans delivered lower normal lung V 5 Gy with similar V 20 Gy and similar target coverage. Based on current clinical guidelines, proton plans were ranked superior to IMRT plans for all 10 patients. However, the proton and IMRT normal lung gEUD(a) curves crossed for 8 patients within the tested range of "a", which means there was a possibility that proton plan would be worse than IMRT plan for lung sparing. A concept of deficiency index (DI) was introduced to quantify the probability of proton plans doing worse than IMRT plans. By applying threshold on DI, four patients' proton plan was ranked inferior to the IMRT plan. Meanwhile if a threshold to the location of curve crossing was applied, 6 patients' proton plan was ranked inferior to the IMRT plan. The contradictory ranking results between the current clinical guidelines and the gEUD(a) curve analysis demonstrated there is potential pitfalls by applying photon experience directly to the proton world. A comprehensive plan evaluation based on radio-biological models should be carried out to decide if a lung patient would really be benefit from proton therapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  2. Phase II study to assess the efficacy of conventionally fractionated radiotherapy followed by a stereotactic radiosurgery boost in patients with locally advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Koong, Albert C.; Christofferson, Erin; Le, Quynh-Thu; Goodman, Karyn A.; Ho, Anthony; Kuo, Timothy; Ford, James M.; Fisher, George A.; Greco, Ralph; Norton, Jeffrey; Yang, George P.

    2005-01-01

    Purpose: To determine the efficacy of concurrent 5-fluorouracil (5-FU) and intensity-modulated radiotherapy (IMRT) followed by body stereotactic radiosurgery (SRS) in patients with locally advanced pancreatic cancer. Methods and Materials: In this prospective study, all patients (19) had pathologically confirmed adenocarcinoma and were uniformly staged. Our treatment protocol consisted of 45 Gy IMRT with concurrent 5-FU followed by a 25 Gy SRS boost to the primary tumor. Results: Sixteen patients completed the planned therapy. Two patients experienced Grade 3 toxicity (none had more than Grade 3 toxicity). Fifteen of these 16 patients were free from local progression until death. Median overall survival was 33 weeks. Conclusions: Concurrent IMRT and 5-FU followed by SRS in patients with locally advanced pancreatic cancer results in excellent local control, but does not improve overall survival and is associated with more toxicity than SRS, alone

  3. Quality assurance for respiratory-gated stereotactic body radiation therapy in lung using real-time position management system

    International Nuclear Information System (INIS)

    Nakaguchi, Yuji; Maruyama, Masato; Araki, Fujio; Kouno, Tomohiro

    2012-01-01

    In this study, we investigated comprehensive quality assurance (QA) for respiratory-gated stereotactic body radiation therapy (SBRT) in the lungs using a real-time position management system (RPM). By using the phantom study, we evaluated dose liberality and reproducibility, and dose distributions for low monitor unite (MU), and also checked the absorbed dose at isocenter and dose profiles for the respiratory-gated exposure using RPM. Furthermore, we evaluated isocenter dose and dose distributions for respiratory-gated SBRT plans in the lungs using RPM. The maximum errors for the dose liberality were 4% for 2 MU, 1% for 4-10 MU, and 0.5% for 15 MU and 20 MU. The dose reproducibility was 2% for 1 MU and within 0.1% for 5 MU or greater. The accuracy for dose distributions was within 2% for 2 MU or greater. The dose error along a central axis for respiratory cycles of 2, 4, and 6 sec was within 1%. As for geometric accuracy, 90% and 50% isodose areas for the respiratory-gated exposure became almost 1 mm and 2 mm larger than without gating, respectively. For clinical lung-SBRT plans, the point dose at isocenter agreed within 2.1% with treatment planning system (TPS). And the pass rates of all plans for TPS were more than 96% in the gamma analysis (3 mm/3%). The geometrical accuracy and the dose accuracy of TPS calculation algorithm are more important for the dose evaluation at penumbra region for respiratory-gated SBRT in lung using RPM. (author)

  4. EPID-based in vivo dosimetry for stereotactic body radiotherapy of non-small cell lung tumors: Initial clinical experience.

    Science.gov (United States)

    Consorti, R; Fidanzio, A; Brainovich, V; Mangiacotti, F; De Spirito, M; Mirri, M A; Petrucci, A

    2017-10-01

    EPID-based in vivo dosimetry (IVD) has been implemented for stereotactic body radiotherapy treatments of non-small cell lung cancer to check both isocenter dose and the treatment reproducibility comparing EPID portal images. 15 patients with lung tumors of small dimensions and treated with volumetric modulated arc therapy were enrolled for this initial experience. IVD tests supplied ratios R between in vivo reconstructed and planned isocenter doses. Moreover a γ-like analysis between daily EPID portal images and a reference one, in terms of percentage of points with γ-value smaller than 1, P γlevels of 5% for R ratio, P γlevel, and an average P γ90%. Paradigmatic discrepancies were observed in three patients: a set-up error and a patient morphological change were identified thanks to CBCT image analysis whereas the third discrepancy was not fully justified. This procedure can provide improved patient safety as well as a first step to integrate IVD and CBCT dose recalculation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Emerging radiotherapy technology in a developing country: A single Brazilian institution assessment of stereotactic body radiotherapy application

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Fabio Ynoe; Bonifacio, Lorine Arias; Neves-Junior, Wellington Pimenta; Hanna, Samir Abdallah; Abreu, Carlos Eduardo Cintra Vita; Arruda, Fernando Freire; Silva, Joao Luis Fernandes; Carvalho, Heloisa Andrade, E-mail: fymoraes@gmail.com [Hospital Sirio-Libanes, Sao Paulo, SP(Brazil)

    2016-11-15

    Objective: To provide a quantitative profile of the indications and use of stereotactic body radiotherapy (SBRT) in a developing country oncology-based institution. In addition, to describe the patient and treatment characteristics, and to provide a temporal analysis. Method: SBRT patients treated from 2007 to 2015 were retrospectively evaluated by two independently investigators. Data were stratified and compared in two periods: first experience (FE) (May 2007 to April 2011), and following experience (FollowE) (May 2011 to April 2015). The following parameters were compared between the groups: total number of treated patients and lesions, treatment site, additional image fusion used, formal protocol adoption, and SBRT planning technique. Results: One hundred and seventy-six (176) patients with 191 lesions were treated: 34 (18%) lesions in the FE and 157 (82%) lesions in FollowE. The majority of lesions were metastases (60.3%), and lung (60.2%) was the most common treatment site, followed by spine (31%), and others (8.8%). An average of 1.4 (±0.6) additional imaging exams for delineation was performed. Conformal 3D radiotherapy planning technique was used in 64.4%, and intensity modulated radiotherapy (IMRT) or volumetric-modulated arc therapy (VMAT) in the remaining 35.6% (p=0.0001). Higher rates of curative treatments were observed in FE, as well as more lung lesions, patients ≥ 70 years, 3D conformal, number of additional images and ECOG 0, and all presented p<0.05. The global rate of protocol statement was 79%, lung treatment being the most stated. Conclusion: SBRT application is rapidly increasing in our setting. Treatment sites and planning techniques are becoming more diversified and complex. (author)

  6. Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Kwang-Ho; Kang, Sei-Kwon; Lee, MeYeon; Kim, Su SSan; Park, SoAh; Hwang, Tae-Jin; Kim, Kyoung Ju; Oh, Do Hoon; Bae, Hoonsik; Suh, Tae-Suk [Department of Radiation Oncology, Hallym University College of Medicine, Seoul, 431070 (Korea, Republic of) and Department of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul 137701 (Korea, Republic of); Department of Radiation Oncology, Hallym University College of Medicine, Seoul 431070 (Korea, Republic of); Department of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul 137701 (Korea, Republic of)

    2010-03-15

    Purpose: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. Methods: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. Results: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within {+-}2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within {+-}0.5 MU regardless of dose rate and duty cycle. Conclusions: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.

  7. Lung stereotactic body radiotherapy using a coplanar versus a non-coplanar beam technique: a comparison of clinical outcomes

    Science.gov (United States)

    Stauder, Michael C.; Miller, Robert C.; Garces, Yolanda I.; Foote, Robert L.; Sarkaria, Jann N.; Bauer, Heather J.; Mayo, Charles S.; Olivier, Kenneth R.

    2013-01-01

    Objectives To determine if lung stereotactic body radiotherapy (SBRT) using a coplanar beam technique was associated with similar outcomes as lung SBRT using a non-coplanar beam technique. Methods A retrospective review was performed of patients undergoing lung SBRT between January 2008 and April 2011. SBRT was initially delivered with multiple non-coplanar, non-overlapping beams; however, starting in December 2009, SBRT was delivered predominantly with all coplanar beams in order to reduce treatment time and complexity. Results This analysis included 149 patients; the median follow-up was 21 months. SBRT was delivered for primary (n = 90) or recurrent (n = 17) non-small cell lung cancer, or lung oligometastasis (n = 42). The most common dose (Gy)/fraction (fx) regimens were 48 Gy/4 fx (39%), 54 Gy/3 fx (37%), and 50 Gy/5 fx (17%). The beam arrangement was coplanar in 61 patients (41%) and non-coplanar in 88 patients (59%). In patients treated with 54 Gy/3 fx, the mean treatment times per fraction for the coplanar and non-coplanar cohorts were 10 and 14 minutes (p < 0.0001). Kaplan-Meier 2-year estimates of overall survival (OS), progression-free survival, and local control (LC) for the coplanar and non-coplanar cohorts were 65% vs. 56% (p = 0.30), 47% vs. 39% (p = 0.71), and 92% and 92% (p = 0.94), respectively. The 1-year estimates of grade 2-5 pulmonary toxicity for the coplanar and non-coplanar cohorts were 11% and 17%, respectively (p = 0.30). On multivariate analysis, beam arrangement was not significantly associated with OS, LC or pulmonary toxicity. Conclusions Patients treated with lung SBRT using a coplanar technique had similar outcomes as those treated with a non-coplanar technique. PMID:29296365

  8. Dose–Response for Stereotactic Body Radiotherapy in Early-Stage Non–Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Olsen, Jeffrey R.; Robinson, Clifford G.; El Naqa, Issam; Creach, Kimberly M.; Drzymala, Robert E.; Bloch, Charles; Parikh, Parag J.; Bradley, Jeffrey D.

    2011-01-01

    Purpose: To compare the efficacy of three lung stereotactic body radiotherapy (SBRT) regimens in a large institutional cohort. Methods: Between 2004 and 2009, 130 patients underwent definitive lung cancer SBRT to a single lesion at the Mallinckrodt Institute of Radiology. We delivered 18 Gy × 3 fractions for peripheral tumors (n = 111) and either 9 Gy × 5 fractions (n = 8) or 10 Gy × 5 fractions (n = 11) for tumors that were central or near critical structures. Univariate and multivariate analysis of prognostic factors was performed using the Cox proportional hazard model. Results: Median follow-up was 11, 16, and 13 months for the 9 Gy × 5, 10 Gy × 5, and 18 Gy × 3 groups, respectively. Local control statistics for Years 1 and 2 were, respectively, 75% and 50% for 9 Gy × 5, 100% and 100% for 10 Gy × 5, and 99% and 91% for 18 Gy × 3. Median overall survival was 14 months, not reached, and 34 months for the 9 Gy × 5, 10 Gy × 5, and 18 Gy × 3 treatments, respectively. No difference in local control or overall survival was found between the 10 Gy × 5 and 18 Gy × 3 groups on log–rank test, but both groups had improved local control and overall survival compared with 9 Gy × 5. Treatment with 9 Gy × 5 was the only independent prognostic factor for reduced local control on multivariate analysis, and increasing age, increasing tumor volume, and poor performance status predicted independently for reduced overall survival. Conclusion: Treatment regimens of 10 Gy × 5 and 18 Gy × 3 seem to be efficacious for lung cancer SBRT and provide superior local control and overall survival compared with 9 Gy × 5.

  9. The influence of target and patient characteristics on the volume obtained from cone beam CT in lung stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Liu, Hong-Wei; Khan, Rao; D’Ambrosi, Rafael; Krobutschek, Krista; Nugent, Zoann; Lau, Harold

    2013-01-01

    Purpose: To investigate the influence of tumor and patient characteristics on the target volume obtained from cone beam CT (CBCT) in lung stereotactic body radiation therapy (SBRT). Materials and methods: For a given cohort of 71 patients, the internal target volume (ITV) in CBCT obtained from four different datasets was compared with a reference ITV drawn on a four-dimensional CT (4DCT). The significance of the tumor size, location, relative target motion (RM) and patient’s body mass index (BMI) and gender on the adequacy of ITV obtained from CBCT was determined. Results: The median ITV-CBCT was found to be smaller than the ITV-4DCT by 11.8% (range: −49.8 to +24.3%, P < 0.001). Small tumors located in the lower lung were found to have a larger RM than large tumors in the upper lung. Tumors located near the central lung had high CT background which reduced the target contrast near the edges. Tumor location close to center vs. periphery was the only significant factor (P = 0.046) causing underestimation of ITV in CBCT, rather than RM (P = 0.323) and other factors. Conclusions: The current clinical study has identified that the location of tumor is a major source of discrepancy between ITV-CBCT and ITV-4DCT for lung SBRT

  10. Automated Volumetric Modulated Arc Therapy Treatment Planning for Stage III Lung Cancer: How Does It Compare With Intensity-Modulated Radio Therapy?

    Energy Technology Data Exchange (ETDEWEB)

    Quan, Enzhuo M. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Chang, Joe Y.; Liao Zhongxing [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Xia Tingyi [Department of Radiation Oncology, Beijing 301 Hospital, Beijing (China); Yuan Zhiyong [Department of Radiation Oncology, Tianjin Medical University Cancer Hospital and Institute, Tianjin (China); Liu Hui [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Radiation Oncology, Zhongshan University Hospital, Guangzhou (China); Li, Xiaoqiang; Wages, Cody A.; Mohan, Radhe [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Zhang Xiaodong, E-mail: xizhang@mdanderson.org [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2012-09-01

    Purpose: To compare the quality of volumetric modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) plans generated by an automated inverse planning system with that of dosimetrist-generated IMRT treatment plans for patients with stage III lung cancer. Methods and Materials: Two groups of 8 patients with stage III lung cancer were randomly selected. For group 1, the dosimetrists spent their best effort in designing IMRT plans to compete with the automated inverse planning system (mdaccAutoPlan); for group 2, the dosimetrists were not in competition and spent their regular effort. Five experienced radiation oncologists independently blind-reviewed and ranked the three plans for each patient: a rank of 1 was the best and 3 was the worst. Dosimetric measures were also performed to quantitatively evaluate the three types of plans. Results: Blind rankings from different oncologists were generally consistent. For group 1, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.6, 2.13, and 2.18, respectively. The auto-VMAT plans in group 1 had 10% higher planning tumor volume (PTV) conformality and 24% lower esophagus V70 (the volume receiving 70 Gy or more) than the manual IMRT plans; they also resulted in more than 20% higher complication-free tumor control probability (P+) than either type of IMRT plans. The auto- and manual IMRT plans in this group yielded generally comparable dosimetric measures. For group 2, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.55, 1.75, and 2.75, respectively. Compared to the manual IMRT plans in this group, the auto-VMAT plans and auto-IMRT plans showed, respectively, 17% and 14% higher PTV dose conformality, 8% and 17% lower mean lung dose, 17% and 26% lower mean heart dose, and 36% and 23% higher P+. Conclusions: mdaccAutoPlan is capable of generating high-quality VMAT and IMRT treatment plans for stage III lung cancer. Manual IMRT plans could achieve quality

  11. Automated Volumetric Modulated Arc Therapy Treatment Planning for Stage III Lung Cancer: How Does It Compare With Intensity-Modulated Radio Therapy?

    International Nuclear Information System (INIS)

    Quan, Enzhuo M.; Chang, Joe Y.; Liao Zhongxing; Xia Tingyi; Yuan Zhiyong; Liu Hui; Li, Xiaoqiang; Wages, Cody A.; Mohan, Radhe; Zhang Xiaodong

    2012-01-01

    Purpose: To compare the quality of volumetric modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) plans generated by an automated inverse planning system with that of dosimetrist-generated IMRT treatment plans for patients with stage III lung cancer. Methods and Materials: Two groups of 8 patients with stage III lung cancer were randomly selected. For group 1, the dosimetrists spent their best effort in designing IMRT plans to compete with the automated inverse planning system (mdaccAutoPlan); for group 2, the dosimetrists were not in competition and spent their regular effort. Five experienced radiation oncologists independently blind-reviewed and ranked the three plans for each patient: a rank of 1 was the best and 3 was the worst. Dosimetric measures were also performed to quantitatively evaluate the three types of plans. Results: Blind rankings from different oncologists were generally consistent. For group 1, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.6, 2.13, and 2.18, respectively. The auto-VMAT plans in group 1 had 10% higher planning tumor volume (PTV) conformality and 24% lower esophagus V70 (the volume receiving 70 Gy or more) than the manual IMRT plans; they also resulted in more than 20% higher complication-free tumor control probability (P+) than either type of IMRT plans. The auto- and manual IMRT plans in this group yielded generally comparable dosimetric measures. For group 2, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.55, 1.75, and 2.75, respectively. Compared to the manual IMRT plans in this group, the auto-VMAT plans and auto-IMRT plans showed, respectively, 17% and 14% higher PTV dose conformality, 8% and 17% lower mean lung dose, 17% and 26% lower mean heart dose, and 36% and 23% higher P+. Conclusions: mdaccAutoPlan is capable of generating high-quality VMAT and IMRT treatment plans for stage III lung cancer. Manual IMRT plans could achieve quality

  12. Interpreting survival data from clinical trials of surgery versus stereotactic body radiation therapy in operable Stage I non-small cell lung cancer patients.

    Science.gov (United States)

    Samson, Pamela; Keogan, Kathleen; Crabtree, Traves; Colditz, Graham; Broderick, Stephen; Puri, Varun; Meyers, Bryan

    2017-01-01

    To identify the variability of short- and long-term survival outcomes among closed Phase III randomized controlled trials with small sample sizes comparing SBRT (stereotactic body radiation therapy) and surgical resection in operable clinical Stage I non-small cell lung cancer (NSCLC) patients. Clinical Stage I NSCLC patients who underwent surgery at our institution meeting the inclusion/exclusion criteria for STARS (Randomized Study to Compare CyberKnife to Surgical Resection in Stage I Non-small Cell Lung Cancer), ROSEL (Trial of Either Surgery or Stereotactic Radiotherapy for Early Stage (IA) Lung Cancer), or both were identified. Bootstrapping analysis provided 10,000 iterations to depict 30-day mortality and three-year overall survival (OS) in cohorts of 16 patients (to simulate the STARS surgical arm), 27 patients (to simulate the pooled surgical arms of STARS and ROSEL), and 515 (to simulate the goal accrual for the surgical arm of STARS). From 2000 to 2012, 749/873 (86%) of clinical Stage I NSCLC patients who underwent resection were eligible for STARS only, ROSEL only, or both studies. When patients eligible for STARS only were repeatedly sampled with a cohort size of 16, the 3-year OS rates ranged from 27 to 100%, and 30-day mortality varied from 0 to 25%. When patients eligible for ROSEL or for both STARS and ROSEL underwent bootstrapping with n=27, the 3-year OS ranged from 46 to 100%, while 30-day mortality varied from 0 to 15%. Finally, when patients eligible for STARS were repeatedly sampled in groups of 515, 3-year OS narrowed to 70-85%, with 30-day mortality varying from 0 to 4%. Short- and long-term survival outcomes from trials with small sample sizes are extremely variable and unreliable for extrapolation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. An Approach for Practical Multiobjective IMRT Treatment Planning

    International Nuclear Information System (INIS)

    Craft, David; Halabi, Tarek; Shih, Helen A.; Bortfeld, Thomas

    2007-01-01

    Purpose: To introduce and demonstrate a practical multiobjective treatment planning procedure for intensity-modulated radiation therapy (IMRT) planning. Methods and Materials: The creation of a database of Pareto optimal treatment plans proceeds in two steps. The first step solves an optimization problem that finds a single treatment plan which is close to a set of clinical aspirations. This plan provides an example of what is feasible, and is then used to determine mutually satisfiable hard constraints for the subsequent generation of the plan database. All optimizations are done using linear programming. Results: The two-step procedure is applied to a brain, a prostate, and a lung case. The plan databases created allow for the selection of a final treatment plan based on the observed tradeoffs between the various organs involved. Conclusions: The proposed method reduces the human iteration time common in IMRT treatment planning. Additionally, the database of plans, when properly viewed, allows the decision maker to make an informed final plan selection

  14. Stereotactic Radiotherapy in the Treatment of Lung Metastases from Bone and Soft-tissue Sarcomas.

    Science.gov (United States)

    Frakulli, Rezarta; Salvi, Fabrizio; Balestrini, Damiano; Parisi, Alessandro; Palombarini, Marcella; Cammelli, Silvia; Rocca, Michele; Salone, Mariacristina; Longhi, Alessandra; Ferrari, Stefano; Morganti, Alessio G; Frezza, Giovanni

    2015-10-01

    The purpose of this study was to evaluate local control and toxicity in a group of patients treated with stereotactic body radiotherapy (SBRT) for lung metastases (LM) from bone and soft tissue sarcomas. From October 2010 to July 2014, patients with LM from sarcomas not suitable for surgery were treated with daily cone-beam computed tomography-guided SBRT. The dose administered ranged from 30 to 60 Gy in 3-8 fractions. Acute and late toxicity were scored according to Common Terminology Criteria for Adverse Events version 4.0. A total of 24 patients with 68 LM from sarcomas were treated with SBRT. The median follow-up after SBRT was 17 months (range=11-51 months). Two-year actuarial lesion local control and overall survival were 85.9% and 66.4%, respectively. No G3 or greater acute and late toxicities were observed. SBRT is a safe and effective treatment for LM from sarcoma and might be used as an alternative option in patients unfit for surgery. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  15. Whole brain radiotherapy with adjuvant or concomitant boost in brain metastasis: dosimetric comparison between helical and volumetric IMRT technique

    International Nuclear Information System (INIS)

    Borghetti, Paolo; Pedretti, Sara; Spiazzi, Luigi; Avitabile, Rossella; Urpis, Mauro; Foscarini, Federica; Tesini, Giulia; Trevisan, Francesca; Ghirardelli, Paolo; Pandini, Sara Angela; Triggiani, Luca; Magrini, Stefano Maria; Buglione, Michela

    2016-01-01

    To compare and evaluate the possible advantages related to the use of VMAT and helical IMRT and two different modalities of boost delivering, adjuvant stereotactic boost (SRS) or simultaneous integrated boost (SIB), in the treatment of brain metastasis (BM) in RPA classes I-II patients. Ten patients were treated with helical IMRT, 5 of them with SRS after whole brain radiotherapy (WBRT) and 5 with SIB. MRI co-registration with planning CT was mandatory and prescribed doses were 30 Gy in 10 fractions (fr) for WBRT and 15Gy/1fr or 45Gy/10fr in SRS or SIB, respectively. For each patient, 4 “treatment plans” (VMAT SRS and SIB, helical IMRT SRS and SIB) were calculated and accepted if PTV boost was included in 95 % isodose and dose constraints of the main organs at risk were respected without major deviations. Homogeneity Index (HI), Conformal Index (CI) and Conformal Number (CN) were considered to compare the different plans. Moreover, time of treatment delivery was calculated and considered in the analysis. Volume of brain metastasis ranged between 1.43 and 51.01 cc (mean 12.89 ± 6.37 ml) and 3 patients had double lesions. V95% resulted over 95 % in the average for each kind of technique, but the “target coverage” was inadequate for VMAT planning with two sites. The HI resulted close to the ideal value of zero in all cases; VMAT-SIB, VMAT-SRS, Helical IMRT-SIB and Helical IMRT-SRS showed mean CI of 2.15, 2.10, 2.44 and 1.66, respectively (optimal range: 1.5–2.0). Helical IMRT-SRS was related to the best and reliable finding of CN (0.66). The mean of treatment time was 210 s, 467 s, 440 s, 1598 s, respectively, for VMAT-SIB, VMAT-SRS, Helical IMRT-SIB and Helical IMRT-SRS. This dosimetric comparison show that helical IMRT obtain better target coverage and respect of CI and CN; VMAT could be acceptable in solitary metastasis. SIB modality can be considered as a good choice for clinical and logistic compliance; literature’s preliminary data are confirming

  16. Stereotactic Radiotherapy of Primary Lung Cancer and Other Targets: Results of Consultant Meeting of the International Atomic Energy Agency

    International Nuclear Information System (INIS)

    Nagata, Yasushi; Wulf, Joern; Lax, Ingmar; Timmerman, Robert; Zimmermann, Frank; Stojkovski, Igor; Jeremic, Branislav

    2011-01-01

    To evaluate the current status of stereotactic body radiotherapy (SBRT) and identify both advantages and disadvantages of its use in developing countries, a meeting composed of consultants of the International Atomic Energy Agency was held in Vienna in November 2006. Owing to continuous developments in the field, the meeting was extended by subsequent discussions and correspondence (2007-2010), which led to the summary presented here. The advantages and disadvantages of SBRT expected to be encountered in developing countries were identified. The definitions, typical treatment courses, and clinical results were presented. Thereafter, minimal methodology/technology requirements for SBRT were evaluated. Finally, characteristics of SBRT for developing countries were recommended. Patients for SBRT should be carefully selected, because single high-dose radiotherapy may cause serious complications in some serial organs at risk. Clinical experiences have been reported in some populations of lung cancer, lung oligometastases, liver cancer, pancreas cancer, and kidney cancer. Despite the disadvantages expected to be experienced in developing countries, SBRT using fewer fractions may be useful in selected patients with various extracranial cancers with favorable outcome and low toxicity.

  17. Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments.

    Science.gov (United States)

    Tyler, Madelaine K

    2016-01-08

    This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5-30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ± 2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ± 15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ± 3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI.

  18. Normal liver tissue sparing by intensity-modulated proton stereotactic body radiotherapy for solitary liver tumours

    International Nuclear Information System (INIS)

    Petersen, Joergen B. B.; Hansen, Anders T.; Lassen, Yasmin; Grau, Cai; Hoeyer, Morten; Muren, Ludvig P.

    2011-01-01

    Background. Stereotactic body radiotherapy (SBRT) is often the preferred treatment for the advanced liver tumours which owing to tumour distribution, size and multi-focality are out of range of surgical resection or radiofrequency ablation. However, only a minority of patients with liver tumours may be candidates for conventional SBRT because of the limited radiation tolerance of normal liver, intestine and other normal tissues. Due to the favourable depth-dose characteristics of protons, intensity-modulated proton therapy (IMPT) may be a superior alternative to photon-based SBRT. The purpose of this treatment planning study was therefore to investigate the potential sparing of normal liver by IMPT compared to photon-based intensity-modulated radiotherapy (IMRT) for solitary liver tumours. Material and methods. Ten patients with solitary liver metastasis treated at our institution with multi-field SBRT were retrospectively re-planned with IMRT and proton pencil beam scanning techniques. For the proton plans, two to three coplanar fields were used in contrast to five to six coplanar and non-coplanar photon fields. The same planning objectives were used for both techniques. A risk adapted dose prescription to the PTV surface of 12.5-16.75 Gy x 3 was used. Results. The spared liver volume for IMPT was higher compared to IMRT in all 10 patients. At the highest prescription dose level, the median liver volume receiving less than 15 Gy was 1411 cm 3 for IMPT and 955 cm 3 for IMRT (p D 15 Gy > 700 cm 3 constraint. For the D mean = 15 Gy constraint, nine of 10 cases could be treated at the highest dose level using IMPT whereas with IMRT, only two cases met this constraint at the highest dose level and six at the lowest dose level. Conclusion. A considerable sparing of normal liver tissue can be obtained using proton-based SBRT for solitary liver tumours

  19. 4D-CT-based target volume definition in stereotactic radiotherapy of lung tumours: Comparison with a conventional technique using individual margins

    International Nuclear Information System (INIS)

    Hof, Holger; Rhein, Bernhard; Haering, Peter; Kopp-Schneider, Annette; Debus, Juergen; Herfarth, Klaus

    2009-01-01

    Purpose: To investigate the dosimetric benefit of integration of 4D-CT in the planning target volume (PTV) definition process compared to conventional PTV definition using individual margins in stereotactic body radiotherapy (SBRT) of lung tumours. Material and methods: Two different PTVs were defined: PTV conv consisting of the helical-CT-based clinical target volume (CTV) enlarged isotropically for each spatial direction by the individually measured amount of motion in the 4D-CT, and PTV 4D encompassing the CTVs defined in the 4D-CT phases displaying the extremes of the tumour position. Tumour motion as well as volumetric and dosimetric differences and relations of both PTVs were evaluated. Results: Volumetric examinations revealed a significant reduction of the mean PTV by 4D-CT from 57.7 to 40.7 cm 3 (31%) (p 4D in PTV conv (r = -0.69, 90% confidence limits: -0.87 and -0.34, p = 0.007). Mean lung dose (MLD) was decreased significantly by 17% (p < 0.001). Conclusions: In SBRT of lung tumours the mere use of individual margins for target volume definition cannot compensate for the additional effects that the implementation of 4D-CT phases can offer.

  20. Influence of intra-fractional breathing movement in step-and-shoot IMRT

    International Nuclear Information System (INIS)

    Schaefer, M; Muenter, M W; Thilmann, C; Sterzing, F; Haering, P; Combs, S E; Debus, J

    2004-01-01

    Efforts have been made to extend the application of intensity-modulated radiotherapy to a variety of organs. One of the unanswered questions is whether breathing-induced organ motion may lead to a relevant over- or underdosage, e.g., in treatment plans for the irradiation of lung cancer. Theoretical considerations have been made concerning the different kinds of IMRT but there is still a lack of experimental data. We examined 18 points in a fraction of a clinical treatment plan of a NSCLC delivered in static IMRT with a new phantom and nine ionization chambers. Measurements were performed at a speed of 12 and 16 breathing cycles per minute. The dose differences between static points and moving target points ranged between -2.4% and +5.5% (mean: +0.2%, median: -0.1%) when moving with 12 cycles min -1 and between -3.6% and +5.0% (mean: -0.4%, median: -0.6%) when moving with 16 cycles min -1 . All differences of measurements with and without movements were below 5%, with one exception. In conclusion, our results underline that at least in static IMRT breathing effects (concerning target dose coverage) due to interplay effects between collimator leaf movement and target movement are of secondary importance and will not reduce the clinical value of IMRT in the step-and-shoot technique for irradiation of thoracic targets. (note)

  1. Evaluation of the Delta4 phantom for IMRT and VMAT verification

    International Nuclear Information System (INIS)

    Bedford, James L; Lee, Young K; Wai, Philip; South, Christopher P; Warrington, Alan P

    2009-01-01

    The Delta 4 diode array phantom (Scandidos, Uppsala, Sweden) was evaluated for verification of segmental intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) on an Elekta linear accelerator (Crawley UK). The device was tested for angular sensitivity by irradiating it from 36 different gantry angles, and the responses of the device to various step-and-shoot segment doses and dose rates were evaluated using an ionization chamber as a comparison. The phantom was then compared with ionization chamber and film results for two prostate and pelvic nodes IMRT plans, two head and neck IMRT plans and two lung VMAT plans. These plans were calculated using Pinnacle 3 (Philips Radiation Oncology Systems, Madison, WI). The uniformity of angular response was better than 0.5% over the range of gantry angles. The uniformity of response of the Delta 4 to different segment monitor units and dose rates was better than 0.5%. The assessment of the IMRT and VMAT plans showed that the Delta 4 measured a dose within 2.5% of the ionization chamber, and compared to film recorded a slightly larger region (range -2% to +7%) agreeing with the planned dose to within 3% and 3 mm. The Delta 4 is a complex device and requires careful benchmarking, but following the successful completion of these measurements, the Delta 4 has been introduced into clinical use. (note)

  2. Computational model to simulate the interplay effect in dynamic IMRT delivery

    International Nuclear Information System (INIS)

    Yoganathan, S A; Maria Das, K J; Kumar, Shaleen

    2014-01-01

    The purpose of this study was to develop and experimentally verify a patient specific model for simulating the interplay effect in a DMLC based IMRT delivery. A computational model was developed using MATLAB program to incorporate the interplay effect in a 2D beams eye view fluence of dynamic IMRT fields. To simulate interplay effect, the model requires two inputs: IMRT field (DMLC file with dose rate and MU) and the patient specific respiratory motion. The interplay between the DMLC leaf motion and target was simulated for three lung patients. The target trajectory data was acquired using RPM system during the treatment simulation. The model was verified experimentally for the same patients using Imatrix 2D array device placed over QUASAR motion platform in CL2100 linac. The simulated fluences and measured fluences were compared with the TPS generated static fluence (no motion) using an in-house developed gamma evaluation program (2%/2mm). The simulated results were well within agreement with the measured. Comparison of the simulated and measured fluences with the TPS static fluence resulted 55.3% and 58.5% pixels passed the gamma criteria. A patient specific model was developed and validated for simulating the interplay effect in the dynamic IMRT delivery. This model can be clinically used to quantify the dosimetric uncertainty due to the interplay effect prior to the treatment delivery.

  3. Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, Jeffrey D. [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Lawrence, Yaacov R. [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Appel, Sarit; Landau, Efrat; Ben-David, Merav A.; Rabin, Tatiana; Benayun, Maoz; Dubinski, Sergey; Weizman, Noam; Alezra, Dror; Gnessin, Hila; Goldstein, Adam M.; Baidun, Khader [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Segel, Michael J.; Peled, Nir [Department of Pulmonary Medicine, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Symon, Zvi, E-mail: symonz@sheba.health.gov.il [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel)

    2015-10-01

    Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm{sup 3} and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.

  4. Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

    International Nuclear Information System (INIS)

    Goldstein, Jeffrey D.; Lawrence, Yaacov R.; Appel, Sarit; Landau, Efrat; Ben-David, Merav A.; Rabin, Tatiana; Benayun, Maoz; Dubinski, Sergey; Weizman, Noam; Alezra, Dror; Gnessin, Hila; Goldstein, Adam M.; Baidun, Khader; Segel, Michael J.; Peled, Nir; Symon, Zvi

    2015-01-01

    Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm 3 and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy

  5. Management of early-stage non-small cell lung cancer using stereotactic ablative radiotherapy: Controversies, insights, and changing horizons

    International Nuclear Information System (INIS)

    Louie, Alexander V.; Palma, David A.; Dahele, Max; Rodrigues, George B.; Senan, Suresh

    2015-01-01

    The use of stereotactic ablative radiotherapy (SABR) for early-stage non-small cell lung cancer is growing rapidly, particularly since it has become the recommended therapy for unfit patients in current European and North American guidelines. As three randomized trials comparing surgery and SABR closed prematurely because of poor accrual, clinicians are faced with a dilemma in individual patient decision-making. Radiation oncologists, in particular, should be aware of the data from comparative effectiveness studies that suggest similar survival outcomes irrespective of local treatment modality. The necessity of obtaining a pathological diagnosis, particularly in frail patients prior to treatment remains a challenge, and this topic was addressed in recent European recommendations. Awareness of the high incidence of a second primary lung cancer in survivors, as well as other competing causes of mortality, is needed. The challenges in distinguishing focal scarring from recurrence after SABR also need to be appreciated by multidisciplinary tumor boards. With a shift in focus toward patient-centered decision-making, clinicians will need to be aware of these new developments and communicate effectively with patients, to ensure that treatment decisions are reflective of patient preferences. Priorities for additional research in the area are proposed

  6. Implementation of IMRT in a real case of breast cancer radiotherapy in the 'Hospital Hermanos Ameijeiras' Service

    International Nuclear Information System (INIS)

    Rodriguez Zayas, Michael; Correa Pablos, Tamara; Perez Guevara, Adrian; Gonzalez Perez, Yelina; Sola Rodriguez, Yeline; Reyes Gonzalez, Tommy; Caballero, Roberto; Del Castillo Carrillo, Concepcion; Mena Huerta, Yailen

    2009-01-01

    Patients with left breast cancer suggest a clinical challenge because it radiates significantly heart, lung and contralateral breast with tangential beam techniques. We performed a study to: (1) design a plan using intensity modulated radiation therapy (IMRT), (2) compare IMRT plan with a plan of 3DCRT beam shear, (3) quantify the benefits of a treatment modality over another. A case diagnosed with breast cancer and treated with IMRT planned. The planning is done with the TPS Precise Plan version 2.16, with the inverse method based on openings, the treatment is carried out by way of step and shoot in the Elekta Precise Linac model with nominal energy of photons 6mV (TPR20, 10 = 0.681). (Author)

  7. Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Ding, George X.; Duggan, Dennis M.; Lu Bo; Hallahan, Dennis E.; Cmelak, Anthony; Malcolm, Arnold; Newton, Jared; Deeley, Matthew; Coffey, Charles W.

    2007-01-01

    The purpose of this study is to assess the real target dose coverage when radiation treatments were delivered to lung cancer patients based on treatment planning according to the RTOG-0236 Protocol. We compare calculated dosimetric results between the more accurate anisotropic analytical algorithm (AAA) and the pencil beam algorithm for stereotactic body radiation therapy treatment planning in lung cancer. Ten patients with non-small cell lung cancer were given 60 Gy in three fractions using 6 and 10 MV beams with 8-10 fields. The patients were chosen in accordance with the lung RTOG-0236 protocol. The dose calculations were performed using the pencil beam algorithm with no heterogeneity corrections (PB-NC) and then recalculated with the pencil beam with modified Batho heterogeneity corrections (PB-MB) and the AAA using an identical beam setup and monitor units. The differences in calculated dose to 95% or 99% of the PTV, between using the PB-NC and the AAA, were within 10% of prescribed dose (60 Gy). However, the minimum dose to 95% and 99% of PTV calculated using the PB-MB were consistently overestimated by up to 40% and 36% of the prescribed dose, respectively, compared to that calculated by the AAA. Using the AAA as reference, the calculated maximum doses were underestimated by up to 27% using the PB-NC and overestimated by 19% using the PB-MB. The calculations of dose to lung from PB-NC generally agree with that of AAA except in the small high-dose region where PB-NC underestimates. The calculated dose distributions near the interface using the AAA agree with those from Monte Carlo calculations as well as measured values. This study indicates that the real minimum PTV dose coverage cannot be guaranteed when the PB-NC is used to calculate the monitor unit settings in dose prescriptions

  8. Is it sufficient to repeat LINEAR accelerator stereotactic radiosurgery in choroidal melanoma?

    Science.gov (United States)

    Furdova, A; Horkovicova, K; Justusova, P; Sramka, M

    One day session LINAC based stereotactic radiosurgery (SRS) at LINAC accelerator is a method of "conservative" attitude to treat the intraocular malignant uveal melanoma. We used model Clinac 600 C/D Varian (system Aria, planning system Corvus version 6.2 verification IMRT OmniPro) with 6 MeV X by rigid immobilization of the eye to the Leibinger frame. The stereotactic treatment planning after fusion of CT and MRI was optimized according to the critical structures (lens, optic nerve, also lens and optic nerve at the contralateral side, chiasm). The first plan was compared and the best plan was applied for therapy at C LINAC accelerator. The planned therapeutic dose was 35.0 Gy by 99 % of DVH (dose volume histogram). In our clinical study in the group of 125 patients with posterior uveal melanoma treated with SRS, in 2 patients (1.6 %) was repeated SRS indicated. Patient age of the whole group ranged from 25 to 81 years with a median of 54 TD was 35.0 Gy. In 2 patients after 5 year interval after stereotactic radiosurgery for uveal melanoma stage T1, the tumor volume increased to 50 % of the primary tumor volume and repeated SRS was necessary. To find out the changes in melanoma characteristics after SRS in long term interval after irradiation is necessary to follow up the patient by an ophthalmologist regularly. One step LINAC based stereotactic radiosurgery with a single dose 35.0 Gy is one of treatment options to treat T1 to T3 stage posterior uveal melanoma and to preserve the eye globe. In some cases it is possible to repeat the SRS after more than 5 year interval (Fig. 8, Ref. 23).

  9. Potential for Interfraction Motion to Increase Esophageal Toxicity in Lung SBRT

    OpenAIRE

    Pham, Anthony Hoai-Nam; Yorke, Ellen; Rimner, Andreas; Wu, Abraham Jing-Ching

    2017-01-01

    Purpose: To characterize the effect of the relative motion of esophagus and tumor on radiation doses to the esophagus in patients treated with stereotactic body radiation therapy for central lung tumors. Methods and Materials: Fifty fractions of stereotactic body radiation therapy in 10 patients with lung tumors within 2.5 cm of the esophagus were reviewed. The esophagus was delineated on each treatment’s cone-beam computed tomography scan and compared to its position on the planning scan. Do...

  10. Enable dosimetric of the Stereotactic Body Frame from Elekta in treatment planning systems for Radiotherapy

    International Nuclear Information System (INIS)

    Gonzalez Perez, Y.; Caballero Pinelo, R.; Alfonso Laguardia, R.

    2015-01-01

    The purpose of this study is to evaluate the commissioning of a stereotactic body frame (SBF ® , Elekta) professional treatment planning systems (TPS) model Elekta's PrecisePlan ® and ERGO++®, for highly foxused delivery of megavoltage photon beams intended for treating tumors located in the thorax and abdominal region. For this purpose we applicated a dedicate stereotactic body frame (SBF ® , Elekta) intended for high precision radiotherapy in extra-cranial located tumors was studied. Issues associated with their implementation in the TPSs were evaluated comparing the dose calculations in two studies of CT under different conditions. an anthropomorphic thorax phantom, model CIRS Thorax IMRT ® , was used in designing several test cases. Ion chamber measurement was permormed in selected points in the phantom, for comparison purposes with dose calculated by the treatment planning systems. The commissioning of the stereotactic body frame (SBF ® , Elekta) and the stereotactic localization was verified, including the dose calculation verification in presence the SBF. The attenuation factors measured for the SBF were obtained and corrected in the TPS PrecisePlan ® , the biggest discrepancies obtained were ∼5% for the oblique sectors (inferior corners), because the minimum permissible value for the software is 0.95 while the real value measured was 0.898. It was studied the SBF, their components and their interference in depth with the photon beams and their implementation in the TPS. The introduction of the correction factors demonstrated to be effective to reduce the eventual errors of dose calculation in the TPS . (Author)

  11. SU-F-J-64: Comparison of Dosimetric Robustness Between Proton Therapy and IMRT Plans Following Tumor Regression for Locally Advanced Non-Small Cell Lung Cancer (NSCLC)

    Energy Technology Data Exchange (ETDEWEB)

    Teng, C; Ainsley, C; Teo, B; Burgdorf, B; Berman, A; Levin, W; Xiao, Y; Lin, L; Simone, C; Solberg, T [University of Pennsylvania, Philadelphia, PA (United States); Janssens, G [IBA, Louvain-la-Neuve (Belgium)

    2016-06-15

    Purpose: In the light of tumor regression and normal tissue changes, dose distributions can deviate undesirably from what was planned. As a consequence, replanning is sometimes necessary during treatment to ensure continued tumor coverage or to avoid overdosing organs at risk (OARs). Proton plans are generally thought to be less robust than photon plans because of the proton beam’s higher sensitivity to changes in tissue composition, suggesting also a higher likely replanning rate due to tumor regression. The purpose of this study is to compare dosimetric deviations between forward-calculated double scattering (DS) proton plans with IMRT plans upon tumor regression, and assesses their impact on clinical replanning decisions. Methods: Ten consecutive locally advanced NSCLC patients whose tumors shrank > 50% in volume and who received four or more CT scans during radiotherapy were analyzed. All the patients received proton radiotherapy (6660 cGy, 180 cGy/fx). Dosimetric robustness during therapy was characterized by changes in the planning objective metrics as well as by point-by-point root-mean-squared differences for the entire PTV, ITV, and OARs (heart, cord, esophagus, brachial plexus and lungs) DVHs. Results: Sixty-four pairs of DVHs were reviewed by three clinicians, who requested a replanning rate of 16.7% and 18.6% for DS and IMRT plans, respectively, with a high agreement between providers. Robustness of clinical indicators was found to depend on the beam orientation and dose level on the DVH curve. Proton dose increased most in OARs distal to the PTV along the beam path, but these changes were primarily in the mid to low dose levels. In contrast, the variation in IMRT plans occurred primarily in the high dose region. Conclusion: Robustness of clinical indicators depends where on the DVH curves comparisons are made. Similar replanning rates were observed for DS and IMRT plans upon large tumor regression.

  12. Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions.

    Science.gov (United States)

    Vergote, Koen; De Deene, Yves; Claus, Filip; De Gersem, Werner; Van Duyse, Bart; Paelinck, Leen; Achten, Eric; De Neve, Wilfried; De Wagter, Carlos

    2003-04-01

    When planning an intensity-modulated radiation therapy (IMRT) treatment in a heterogeneous region (e.g. the thorax), the dose computation algorithm of a treatment planning system may need to account for these inhomogeneities in order to obtain a reliable prediction of the dose distribution. An accurate dose verification technique such as monomer/polymer gel dosimetry is suggested to verify the outcome of the planning system. The effects of low-density structures: (a) on narrow high-energy (18 MV) photon beams; and (b) on a class-solution IMRT treatment delivered to a thorax phantom have been examined using gel dosimetry. The used phantom contained air cavities that could be filled with water to simulate a homogeneous or heterogeneous configuration. The IMRT treatment for centrally located lung tumors was delivered on both cases, and gel derived dose maps were compared with computations by both the GRATIS and Helax-TMS planning system. Dose rebuildup due to electronic disequilibrium in a narrow photon beam is demonstrated. The gel measurements showed good agreement with diamond detector measurements. Agreement between measured IMRT dose maps and dose computations was demonstrated by several quantitative techniques. An underdosage of the planning target volume (PTV) was revealed. The homogeneity of the phantom had only a minor influence on the dose distribution in the PTV. An expansion of low-level isodoses in the lung volume was predicted by collapsed cone computations in the heterogeneous case. For the class-solution described, the dose in centrally located mediastinal tumors can be computed with sufficient accuracy, even when neglecting the lower lung density. Polymer gel dosimetry proved to be a valuable technique to verify dose calculation algorithms for IMRT in 3D in heterogeneous configurations.

  13. Early prediction of lung cancer recurrence after stereotactic radiotherapy using second order texture statistics

    Science.gov (United States)

    Mattonen, Sarah A.; Palma, David A.; Haasbeek, Cornelis J. A.; Senan, Suresh; Ward, Aaron D.

    2014-03-01

    Benign radiation-induced lung injury is a common finding following stereotactic ablative radiotherapy (SABR) for lung cancer, and is often difficult to differentiate from a recurring tumour due to the ablative doses and highly conformal treatment with SABR. Current approaches to treatment response assessment have shown limited ability to predict recurrence within 6 months of treatment. The purpose of our study was to evaluate the accuracy of second order texture statistics for prediction of eventual recurrence based on computed tomography (CT) images acquired within 6 months of treatment, and compare with the performance of first order appearance and lesion size measures. Consolidative and ground-glass opacity (GGO) regions were manually delineated on post-SABR CT images. Automatic consolidation expansion was also investigated to act as a surrogate for GGO position. The top features for prediction of recurrence were all texture features within the GGO and included energy, entropy, correlation, inertia, and first order texture (standard deviation of density). These predicted recurrence with 2-fold cross validation (CV) accuracies of 70-77% at 2- 5 months post-SABR, with energy, entropy, and first order texture having leave-one-out CV accuracies greater than 80%. Our results also suggest that automatic expansion of the consolidation region could eliminate the need for manual delineation, and produced reproducible results when compared to manually delineated GGO. If validated on a larger data set, this could lead to a clinically useful computer-aided diagnosis system for prediction of recurrence within 6 months of SABR and allow for early salvage therapy for patients with recurrence.

  14. Megavoltage conebeam CT cine as final verification of treatment plan in lung stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Kudithipudi, Vijay; Gayou, Olivier; Colonias, Athanasios

    2016-01-01

    To analyse the clinical impact of megavoltage conebeam computed tomography (MV-CBCT) cine on internal target volume (ITV) coverage in lung stereotactic body radiotherapy (SBRT). One hundred and six patients received lung SBRT. All underwent 4D computed tomography simulation followed by treatment via image guided 3D conformal or intensity modulated radiation. Prior to SBRT, all patients underwent MV-CBCT cine, in which raw projections are displayed as beam's-eye-view fluoroscopic series with the planning target volume (PTV) projected onto each image, enabling verification of tumour motion relative to the PTV and assessment of adequacy of treatment margin. Megavoltage conebeam computed tomography cine was completed 1–2 days prior to SBRT. Four patients (3.8%) had insufficient ITV coverage inferiorly at cine review. All four plans were changed by adding 5 mm on the PTV margin inferiorly. The mean change in PTV volumes was 3.9 cubic centimetres (cc) (range 1.85–6.32 cc). Repeat cine was performed after plan modification to ensure adequate PTV coverage in the modified plans. PTV margin was adequate in the majority of patients with this technique. MV-CBCT cine did show insufficient coverage in a small subset of patients. Insufficient PTV margins may be a function of 4D CT simulation inadequacies or deficiencies in visualizing the ITV inferior border in the full-inhale phase. MV-CBCT cine is a valuable tool for final verification of PTV margins.

  15. Stereotactic radiotherapy of histologically proven inoperable stage I non-small cell lung cancer: Patterns of failure

    International Nuclear Information System (INIS)

    Andratschke, Nicolaus; Zimmermann, Frank; Boehm, Eva; Schill, Sabine; Schoenknecht, Christine; Thamm, Reinhard; Molls, Michael; Nieder, Carsten; Geinitz, Hans

    2011-01-01

    Background and purpose: To report patterns of failure of stereotactic body radiation therapy (SBRT) in inoperable patients with histologically confirmed stage I NSCLC. Materials and methods: Ninety-two inoperable patients (median age: 75 years) with clinically staged, histologically proven T1 (n = 31) or T2 (n = 61), N0, M0 non-small cell lung cancer (NSCLC) were included in this study. Treatment consisted of 3–5 fractions with 7–15 Gy per fraction prescribed to the 60% isodose. Results: Freedom from local recurrence at 1, 3 and 5 years was 89%, 83% and 83%, respectively. All 10 local failures were observed in patients with T2 tumors. Isolated regional recurrence was observed in 7.6%. The crude rate of distant progression was 20.7%. Overall survival at 1, 3, and 5 years was 79%, 38% and 17% with a median survival of 29 months. Disease specific survival at 1, 3, and 5 years was 93%, 64% and 48%. Karnofsky performance status, T stage, gross tumor volume and tumor location had no significant impact on overall and disease specific survival. SBRT was generally well tolerated and all patients completed therapy as planned. Conclusion: SBRT for stage I lung cancer is very well tolerated in this patient cohort with significant cardiopulmonal comorbidity and results in excellent local control rates, although a considerable portion develops regional and distant metastases.

  16. Dosimetric Impact of the Interplay Effect During Stereotactic Lung Radiation Therapy Delivery Using Flattening Filter-Free Beams and Volumetric Modulated Arc Therapy

    International Nuclear Information System (INIS)

    Ong, Chin Loon; Dahele, Max; Slotman, Ben J.; Verbakel, Wilko F.A.R.

    2013-01-01

    Purpose: We investigated the dosimetric impact of the interplay effect during RapidArc stereotactic body radiation therapy for lung tumors using flattening filter-free (FFF) beams with different dose rates. Methods and Materials: Seven tumors with motion ≤20 mm, treated with 10-MV FFF RapidArc, were analyzed. A programmable phantom with sinusoidal longitudinal motion (30-mm diameter “tumor” insert; period = 5 s; individualized amplitude from planning 4-dimensional computed tomography) was used for dynamic dose measurements. Measurements were made with GafChromic EBT III films. Plans delivered the prescribed dose to 95% of the planning target volume, created by a 5-mm expansion of the internal target volume. They comprised 2 arcs and maximum dose rates of 400 and 2400 MU/min. For 2400 MU/min plans, measurements were repeated at 3 different initial breathing phases to model interplay over 2 to 3 fractions. For 3 cases, 2 extra plans were created using 1 full rotational arc (with contralateral lung avoidance sector) and 1 partial arc of 224° to 244°. Dynamic and convolved static measurements were compared by use of gamma analysis of 3% dose difference and 1 mm distance-to-agreement. Results: For 2-arc 2400 MU/min plans, maximum dose deviation of 9.4% was found in a single arc; 7.4% for 2 arcs (single fraction) and 99% of the area within the region of interest passed the gamma criteria when all 3 measurements with different initial phases were combined. Single-fraction single-arc plans showed higher dose deviations, which diminished when dose distributions were summed over 2 fractions. All 400 MU/min plans showed good agreement in a single fraction measurement. Conclusion: Under phantom conditions, single-arc and single-fraction 2400 MU/min FFF RapidArc lung stereotactic body radiation therapy is susceptible to interplay. Two arcs and ≥2 fractions reduced the effect to a level that appeared unlikely to be clinically significant

  17. Cine Computed Tomography Without Respiratory Surrogate in Planning Stereotactic Radiotherapy for Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Riegel, Adam C. B.A.; Chang, Joe Y.; Vedam, Sastry S.; Johnson, Valen; Chi, Pai-Chun Melinda; Pan, Tinsu

    2009-01-01

    Purpose: To determine whether cine computed tomography (CT) can serve as an alternative to four-dimensional (4D)-CT by providing tumor motion information and producing equivalent target volumes when used to contour in radiotherapy planning without a respiratory surrogate. Methods and Materials: Cine CT images from a commercial CT scanner were used to form maximum intensity projection and respiratory-averaged CT image sets. These image sets then were used together to define the targets for radiotherapy. Phantoms oscillating under irregular motion were used to assess the differences between contouring using cine CT and 4D-CT. We also retrospectively reviewed the image sets for 26 patients (27 lesions) at our institution who had undergone stereotactic radiotherapy for Stage I non-small-cell lung cancer. The patients were included if the tumor motion was >1 cm. The lesions were first contoured using maximum intensity projection and respiratory-averaged CT image sets processed from cine CT and then with 4D-CT maximum intensity projection and 10-phase image sets. The mean ratios of the volume magnitude were compared with intraobserver variation, the mean centroid shifts were calculated, and the volume overlap was assessed with the normalized Dice similarity coefficient index. Results: The phantom studies demonstrated that cine CT captured a greater extent of irregular tumor motion than did 4D-CT, producing a larger tumor volume. The patient studies demonstrated that the gross tumor defined using cine CT imaging was similar to, or slightly larger than, that defined using 4D-CT. Conclusion: The results of our study have shown that cine CT is a promising alternative to 4D-CT for stereotactic radiotherapy planning

  18. SU-F-T-212: A Comparison of Treatment Strategies for Intracranial Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Lamberton, T; Slater, J; Wroe, A

    2016-01-01

    Purpose: Stereotactic radiosurgery is an effective and noninvasive treatment for intracranial lesions that uses highly focused radiation beams in a single treatment fraction. The purpose of this study is to investigate the dosimetric differences between the treatment brain metastasis with a proton beam vs. intensity modulated radiation therapy (IMRT). Methods: Ten separate brain metastasis targets where chosen and treatment plans were created for each, using three different strategies: custom proton beam shaping devices, standardized proton beam shaping devices, and IMRT. Each plan was required to satisfy set parameters for providing adequate coverage and minimizing risk to adjacent tissues. The effectiveness of each plan was calculated by comparing the homogeneity index, conformity index, and V12 for each target using a paired one tailed T-test (α=0.05). Specific comparison of the conformity indices was also made using a subcategory containing targets with volume>1cc. Results: There was no significant difference between the homogeneity indices of the three plans (p>0.05), showing that each plan has the capability of adequately covering the targets. There was a statistically significant difference (p 1cc) there was no statistical difference between the proton plans and the IMRT treatment for the conformity index. Conclusion: A custom proton plan is the recommended treatment explored in this study as it is the most reliable way of effectively treating the target while sparing the maximum amount of normal tissue.

  19. Functional image-based radiotherapy planning for non-small cell lung cancer: A simulation study

    International Nuclear Information System (INIS)

    Bates, Emma L.; Bragg, Christopher M.; Wild, Jim M.; Hatton, Matthew Q.F.; Ireland, Rob H.

    2009-01-01

    Background and purpose: To investigate the incorporation of data from single-photon emission computed tomography (SPECT) or hyperpolarized helium-3 magnetic resonance imaging ( 3 He-MRI) into intensity-modulated radiotherapy (IMRT) planning for non-small cell lung cancer (NSCLC). Material and methods: Seven scenarios were simulated that represent cases of NSCLC with significant functional lung defects. Two independent IMRT plans were produced for each scenario; one to minimise total lung volume receiving ≥20 Gy (V 20 ), and the other to minimise only the functional lung volume receiving ≥20 Gy (FV 20 ). Dose-volume characteristics and a plan quality index related to planning target volume coverage by the 95% isodose (V PTV95 /FV 20 ) were compared between anatomical and functional plans using the Wilcoxon signed ranks test. Results: Compared to anatomical IMRT plans, functional planning reduced FV 20 (median 2.7%, range 0.6-3.5%, p = 0.02), and total lung V 20 (median 1.5%, 0.5-2.7%, p = 0.02), with a small reduction in mean functional lung dose (median 0.4 Gy, 0-0.7 Gy, p = 0.03). There were no significant differences in target volume coverage or organ-at-risk doses. Plan quality index was improved for functional plans (median increase 1.4, range 0-11.8, p = 0.02). Conclusions: Statistically significant reductions in FV 20 , V 20 and mean functional lung dose are possible when IMRT planning is supplemented by functional information derived from SPECT or 3 He-MRI.

  20. Delayed esophageal perforation from stereotactic body radiation therapy for locally recurrent central nonsmall cell lung cancer

    Directory of Open Access Journals (Sweden)

    Sandeep Sainathan

    2014-01-01

    Full Text Available Stereotactic body radiation therapy (SBRT is a novel form of external beam radiation therapy. It is used to treat early and locally recurrent nonsmall cell lung cancer (NSLC in medically inoperable patients. It uses high dose, hypofractionated radiotherapy, with targeting of the tumor by precise spatial localization, thus minimizing injury to surrounding tissues. It can be safely used to ablate NSLC in both central and peripheral locations. We present two cases of delayed esophageal perforation after SBRT for locally recurrent central NSLC. The perforations occurred several months after the therapy. They were treated with covered esophageal stents, with mortality, due to the perforation in one of the patients. SBRT should be judiciously used to ablate centrally located NSLC and patients who develop episodes of esophagitis during or after SBRT, need to be closely followed with endoscopy to look for esophageal ulcerations. These ulcers should be closely followed for healing as these may degenerate into full thickness perforations several months after SBRT.

  1. Quality assurance device for four-dimensional IMRT or SBRT and respiratory gating using patient-specific intrafraction motion kernels.

    Science.gov (United States)

    Nelms, Benjamin E; Ehler, Eric; Bragg, Henry; Tomé, Wolfgang A

    2007-09-17

    Emerging technologies such as four-dimensional computed tomography (4D CT) and implanted beacons are expected to allow clinicians to accurately model intrafraction motion and to quantitatively estimate internal target volumes (ITVs) for radiation therapy involving moving targets. In the case of intensity-modulated (IMRT) and stereotactic body radiation therapy (SBRT) delivery, clinicians must consider the interplay between the temporal nature of the modulation and the target motion within the ITV. A need exists for a 4D IMRT/SBRT quality assurance (QA) device that can incorporate and analyze customized intrafraction motion as it relates to dose delivery and respiratory gating. We built a 4D IMRT/SBRT prototype device and entered (X, Y, Z)(T) coordinates representing a motion kernel into a software application that 1. transformed the kernel into beam-specific two-dimensional (2D) motion "projections," 2. previewed the motion in real time, and 3. drove a recision X-Y motorized device that had, atop it, a mounted planar IMRT QA measurement device. The detectors that intersected the target in the beam's-eye-view of any single phase of the breathing cycle (a small subset of all the detectors) were defined as "target detectors" to be analyzed for dose uniformity between multiple fractions. Data regarding the use of this device to quantify dose variation fraction-to-fraction resulting from target motion (for several delivery modalities and with and without gating) have been recently published. A combined software and hardware solution for patient-customized 4D IMRT/SBRT QA is an effective tool for assessing IMRT delivery under conditions of intrafraction motion. The 4D IMRT QA device accurately reproduced the projected motion kernels for all beam's-eye-view motion kernels. This device has been proved to, effectively quantify the degradation in dose uniformity resulting from a moving target within a static planning target volume, and, integrate with a commercial

  2. Quality assurance device for four‐dimensional IMRT or SBRT and respiratory gating using patient‐specific intrafraction motion kernels

    Science.gov (United States)

    Ehler, Eric; Bragg, Henry; Tomé, Wolfgang A.

    2007-01-01

    Emerging technologies such as four‐dimensional computed tomography (4D CT) and implanted beacons are expected to allow clinicians to accurately model intrafraction motion and to quantitatively estimate internal target volumes (ITVs) for radiation therapy involving moving targets. In the case of intensity‐modulated (IMRT) and stereotactic body radiation therapy (SBRT) delivery, clinicians must consider the interplay between the temporal nature of the modulation and the target motion within the ITV. A need exists for a 4D IMRT/SBRT quality assurance (QA) device that can incorporate and analyze customized intrafraction motion as it relates to dose delivery and respiratory gating. We built a 4D IMRT/SBRT prototype device and entered (X, Y, Z)(T) coordinates representing a motion kernel into a software application that transformed the kernel into beam‐specific two‐dimensional (2D) motion “projections,”previewed the motion in real time, anddrove a precision X–Y motorized device that had, atop it, a mounted planar IMRT QA measurement device. The detectors that intersected the target in the beam's‐eye‐view of any single phase of the breathing cycle (a small subset of all the detectors) were defined as “target detectors” to be analyzed for dose uniformity between multiple fractions. Data regarding the use of this device to quantify dose variation fraction‐to‐fraction resulting from target motion (for several delivery modalities and with and without gating) have been recently published. A combined software and hardware solution for patient‐customized 4D IMRT/ SBRT QA is an effective tool for assessing IMRT delivery under conditions of intrafraction motion. The 4D IMRT QA device accurately reproduced the projected motion kernels for all beam's‐eye‐view motion kernels. This device has been proved to • effectively quantify the degradation in dose uniformity resulting from a moving target within a static planning target volume, and • integrate

  3. SU-E-T-551: Monitor Unit Optimization in Stereotactic Body Radiation Therapy for Stage I Lung Cancer

    International Nuclear Information System (INIS)

    Huang, B-T; Lu, J-Y

    2015-01-01

    Purpose: The study aims to reduce the monitor units (MUs) in the stereotactic body radiation therapy (SBRT) treatment for lung cancer by adjusting the optimizing parameters. Methods: Fourteen patients suffered from stage I Non-Small Cell Lung Cancer (NSCLC) were enrolled. Three groups of parameters were adjusted to investigate their effects on MU numbers and organs at risk (OARs) sparing: (1) the upper objective of planning target volume (UOPTV); (2) strength setting in the MU constraining objective; (3) max MU setting in the MU constraining objective. Results: We found that the parameters in the optimizer influenced the MU numbers in a priority, strength and max MU dependent manner. MU numbers showed a decreasing trend with the UOPTV increasing. MU numbers with low, medium and high priority for the UOPTV were 428±54, 312±48 and 258±31 MU/Gy, respectively. High priority for UOPTV also spared the heart, cord and lung while maintaining comparable PTV coverage than the low and medium priority group. It was observed that MU numbers tended to decrease with the strength increasing and max MU setting decreasing. With maximum strength, the MU numbers reached its minimum while maintaining comparable or improved dose to the normal tissues. It was also found that the MU numbers continued to decline at 85% and 75% max MU setting but no longer to decrease at 50% and 25%. Combined with high priority for UOPTV and MU constraining objectives, the MU numbers can be decreased as low as 223±26 MU/Gy. Conclusion:: The priority of UOPTV, MU constraining objective in the optimizer impact on the MU numbers in SBRT treatment for lung cancer. Giving high priority to the UOPTV, setting the strength to maximum value and the max MU to 50% in the MU objective achieves the lowest MU numbers while maintaining comparable or improved OAR sparing

  4. Implementation of a lung radiosurgery program: technical considerations and quality assurance in an Australian institution

    International Nuclear Information System (INIS)

    Siva, Shankar; MacManus, Michael; Ball, David; Chesson, Brent; Aarons, Yolanda; Clements, Natalie; Kron, Tomas

    2012-01-01

    The Peter MacCallum Cancer Centre has established a stereotactic lung radiosurgery program for the treatment of isolated lung metastases. The aim of this study was to critically assess the technical feasibility of performing stereotactic lung radiosurgery in an Australian institution. A single 26-Gy fraction of radiotherapy was delivered to patients with positron emission tomography (PET) staged solitary lung metastases. Motion management was addressed using four-dimensional computed tomographic simulation, and cone beam CT (CBCT) online soft-tissue matching. Treatments were with multiple coplanar and non-coplanar asymmetric beams. Patients were immobilised in a dedicated stereotactic body cradle. Quality assurance (QA) of treatment plans with both ion chamber and film measurements was performed accounting for patient-specific respiratory motion. Between February 2010 and February 2011, nine patients received stereotactic lung radiosurgery. One grade 1 toxicity and one grade 2 toxicity were recorded after treatment. The mean planning target volume was 22.6 cc. A median of eight beams were delivered per treatment plan (range 7–10) with a median of two non-coplanar beams (range 0–6). At treatment plan QA, the difference between planned and delivered dose was ≤1.76% in all static and dynamic ion chamber recordings. A mid-treatment CBCT was performed at a median time of 21 min, with the mean displacement discrepancy from initial set-up being 0.4 mm (range 0–2 mm). Stereotactic radiosurgery to the lung was both feasible and tolerable at our institution. Intrafractional immobilisation within 2 mm was reproducible. Excellent concordance between planned and delivered treatments was achieved in the phantom QA.

  5. Dosimetric comparison between helical tomotherapy and intensity-modulated radiation therapy plans for non-small cell lung cancer.

    Science.gov (United States)

    Meng, Ling-Ling; Feng, Lin-Chun; Wang, Yun-Lai; Dai, Xiang-Kun; Xie, Chuan-Bin

    2011-06-01

    Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformity, dose gradients, and protection for the lung than IMRT plan. We compared the dosimetric characteristics of HT for NSCLC with those of conventional IMRT to observe the superiority of HT. There was a comparative case series comprising 10 patients with NSCLC. Computed tomographic (CT) images of delineated targets were transferred to the PrecisePlan planning system (IMRT) and Tomo planning system (HT). The prescription doses were 70 Gy/33F for the gross tumor volume (GTV) and the visible lymph nodes (GTVnd), and 60 Gy/33F for the clinical target volume (CTV) and the clinical target volume of the visible lymph nodes (CTVnd). The dose restrictions for organs at risk were as follows: the maximum dose to spinal cord ≤ 45 Gy, V20 to the total lungs 0.05). The maximum doses to the spinal cord, heart, esophagus and trachea in the HT plan were lower than those in the IMRT plan, but the differences were not statistically significant. The HT plan provids better dose uniformity, dose gradients, and protection for the organs at risk. It can reduce the high-dose radiation volume for lung and the MLD, but may deliver a larger lung volume of low-dose radiation.

  6. Is IMRT Superior or Inferior to 3DCRT in Radiotherapy for NSCLC? A Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Xingsheng Hu

    Full Text Available There are no adequate data to determine whether intensity-modulated radiotherapy (IMRT is superior to three-dimensional conformal radiotherapy (3DCRT in the treatment of non-small cell lung cancer (NSCLC. This meta-analysis was conducted to compare the clinical outcomes of IMRT and 3DCRT in the treatment of NSCLC.No exclusions were made based on types of study design. We performed a literature search in PubMed, EMBASE and the Cochrane library databases from their inceptions to April 30, 2015. The overall survival (OS and relative risk (RR of radiation pneumonitis and radiation oesophagitis were evaluated. Two authors independently assessed the methodological quality and extracted data. Publication bias was evaluated by funnel plot using Egger's test results.From the literature search, 10 retrospective studies were collected, and of those, 5 (12,896 patients were selected for OS analysis, 4 (981 patients were selected for radiation pneumonitis analysis, and 4 (1339 patients were selected for radiation oesophagitis analysis. Cox multivariate proportional hazards models revealed that 3DCRT and IMRT had similar OS (HR = 0.96, P = 0.477 but that IMRT reduced the incidence of grade 2 radiation pneumonitis (RR = 0.74, P = 0.009 and increased the incidence of grade 3 radiation oesophagitis (RR = 2.47, P = 0.000.OS of IMRT for NSCLC is not inferior to that of 3DCRT, but IMRT significantly reduces the risk of radiation pneumonitis and increases the risk of radiation oesophagitis compared to 3DCRT.

  7. Stereotactic body radiotherapy for stage I lung cancer and small lung metastasis: evaluation of an immobilization system for suppression of respiratory tumor movement and preliminary results

    Directory of Open Access Journals (Sweden)

    Ayakawa Shiho

    2009-05-01

    Full Text Available Abstract Background In stereotactic body radiotherapy (SBRT for lung tumors, reducing tumor movement is necessary. In this study, we evaluated changes in tumor movement and percutaneous oxygen saturation (SpO2 levels, and preliminary clinical results of SBRT using the BodyFIX immobilization system. Methods Between 2004 and 2006, 53 consecutive patients were treated for 55 lesions; 42 were stage I non-small cell lung cancer (NSCLC, 10 were metastatic lung cancers, and 3 were local recurrences of NSCLC. Tumor movement was measured with fluoroscopy under breath holding, free breathing on a couch, and free breathing in the BodyFIX system. SpO2 levels were measured with a finger pulseoximeter under each condition. The delivered dose was 44, 48 or 52 Gy, depending on tumor diameter, in 4 fractions over 10 or 11 days. Results By using the BodyFIX system, respiratory tumor movements were significantly reduced compared with the free-breathing condition in both craniocaudal and lateral directions, although the amplitude of reduction in the craniocaudal direction was 3 mm or more in only 27% of the patients. The average SpO2 did not decrease by using the system. At 3 years, the local control rate was 80% for all lesions. Overall survival was 76%, cause-specific survival was 92%, and local progression-free survival was 76% at 3 years in primary NSCLC patients. Grade 2 radiation pneumonitis developed in 7 patients. Conclusion Respiratory tumor movement was modestly suppressed by the BodyFIX system, while the SpO2 level did not decrease. It was considered a simple and effective method for SBRT of lung tumors. Preliminary results were encouraging.

  8. IMRT plan verification in radiotherapy

    International Nuclear Information System (INIS)

    Vlk, P.

    2006-01-01

    This article describes the procedure for verification of IMRT (Intensity modulated radiation therapy) plan, which is used in the Oncological Institute of St. Elisabeth in Bratislava. It contains basic description of IMRT technology and developing a deployment plan for IMRT planning system CORVUS 6.0, the device Mimic (Multilammelar intensity modulated collimator) and the overall process of verifying the schedule created. The aim of verification is particularly good control of the functions of MIMIC and evaluate the overall reliability of IMRT planning. (author)

  9. Prognostic indices in stereotactic radiotherapy of brain metastases of non-small cell lung cancer.

    Science.gov (United States)

    Kaul, David; Angelidis, Alexander; Budach, Volker; Ghadjar, Pirus; Kufeld, Markus; Badakhshi, Harun

    2015-11-26

    Our purpose was to analyze the long-term clinical outcome and to identify prognostic factors after Linac-based stereotactic radiosurgery (SRS) or fractionated stereotactic radiotherapy (FSRT) on patients with brain metastases (BM) from non-small cell lung cancer (NSCLC). We performed a retrospective analysis of survival on 90 patients who underwent SRS or FSRT of intracranial NSCLC metastases between 04/2004 and 05/2014 that had not undergone prior surgery or whole brain radiotherapy (WBRT) for BM. Follow-up data was analyzed until May 2015. Potential prognostic factors were examined in univariable and multivariable analyses. The Golden Grading System (GGS), the disease-specific graded prognostic assessment (DS-GPA), the RADES II prognostic index as well as the NSCLC-specific index proposed by Rades et al. in 2013 (NSCLC-RADES) were calculated and their predictive values were tested in univariable analysis. The median follow-up time of the surviving patients was 14 months. The overall survival (OS) rate was 51 % after 6 months and 29.9 % after 12 months. Statistically significant factors of better OS after univariable analysis were lower International Union Against Cancer (UICC) stage at first diagnosis, histology of adenocarcinoma, prior surgery of the primary tumor and lower total BM volume. After multivariable analysis adenocarcinoma histology remained a significant factor; higher Karnofsky Performance Score (KPS) and the presence of extracranial metastases (ECM) were also significant. The RADES II and the NSCLC-RADES indices were significant predictors of OS. However, the NSCLC-RADES failed to differentiate between intermediate- and low-risk patients. The DS-GPA and GGS were not statistically significant predictors of survival in univariable analysis. The ideal prognostic index has not been defined yet. We believe that more specific indices will be developed in the future. Our results indicate that the histologic subtype of NSCLC could add to the prognostic

  10. Influence on dose calculation by difference of dose calculation algorithms in stereotactic lung irradiation. Comparison of pencil beam convolution (inhomogeneity correction: batho power law) and analytical anisotropic algorithm

    International Nuclear Information System (INIS)

    Tachibana, Masayuki; Noguchi, Yoshitaka; Fukunaga, Jyunichi; Hirano, Naomi; Yoshidome, Satoshi; Hirose, Takaaki

    2009-01-01

    The monitor unit (MU) was calculated by pencil beam convolution (inhomogeneity correction algorithm: batho power law) [PBC (BPL)] which is the dose calculation algorithm based on measurement in the past in the stereotactic lung irradiation study. The recalculation was done by analytical anisotropic algorithm (AAA), which is the dose calculation algorithm based on theory data. The MU calculated by PBC (BPL) and AAA was compared for each field. In the result of the comparison of 1031 fields in 136 cases, the MU calculated by PBC (BPL) was about 2% smaller than that calculated by AAA. This depends on whether one does the calculation concerning the extension of the second electrons. In particular, the difference in the MU is influenced by the X-ray energy. With the same X-ray energy, when the irradiation field size is small, the lung pass length is long, the lung pass length percentage is large, and the CT value of the lung is low, and the difference of MU is increased. (author)

  11. The use of IMRT in Germany

    International Nuclear Information System (INIS)

    Frenzel, Thorsten; Kruell, Andreas

    2015-01-01

    Intensity modulated radiotherapy (IMRT) is frequently used, but there are no data about current frequency regarding specific tumor sites and equipment used for quality assurance (QA). An online survey about IMRT was executed from April to October 2014 by the collaborative IMRT working group (AK IMRT) of the German Association of Medical Physicists (DGMP). A total of 23 German institutions took part in the survey. Most reports came from users working with Elekta, Varian, and Siemens treatment machines, but also from TomoTherapy and BrainLab. Most frequent IMRT technology was volumetric modulated arc therapy (58.37 %: VMAT/''rapid arc''), followed by step-and-shoot IMRT (14.66 %), dynamic MLC (dMLC: 14.53 %), TomoTherapy (9.25 %), and 3.2 % other techniques. Different commercial hard- and software solutions are available for QA, whereas many institutes still develop their own phantoms. Data of 26,779 patients were included in the survey; 44 % were treated using IMRT techniques. IMRT was most frequently used for anal cancer, (whole) craniospinal irradiation, head and neck cancer, prostate cancer, other tumors in the pelvic region, gynecological tumors (except for breast cancer), and brain tumors. An estimated 10 % of all patients treated in 2014 with radiation in Germany were included in the survey. It is representative for the members of the AK IMRT. IMRT may be on the way to replace other treatment techniques. However, many scientific questions are still open. In particular, it is unclear when the IMRT technique should not be used. (orig.) [de

  12. Immune Responses following Stereotactic Body Radiotherapy for Stage I Primary Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yoshiyasu Maehata

    2013-01-01

    Full Text Available Purpose. Immune responses following stereotactic body radiotherapy (SBRT for stage I non-small cell lung cancer (NSCLC were examined from the point of view of lymphocyte subset counts and natural killer cell activity (NKA. Patients and Methods. Peripheral blood samples were collected from 62 patients at 4 time points between pretreatment and 4 weeks post-treatment for analysis of the change of total lymphocyte counts (TLC and lymphocyte subset counts of CD3+, CD4+, CD8+, CD19+, CD56+, and NKA. In addition, the changes of lymphocyte subset counts were compared between patients with or without relapse. Further, the correlations between SBRT-related parameters and immune response were analyzed for the purpose of revealing the mechanisms of the immune response. Results. All lymphocyte subset counts and NKA at post-treatment and 1 week post-treatment were significantly lower than pre-treatment (P<0.01. No significant differences in the changes of lymphocyte subset counts were observed among patients with or without relapse. The volume of the vertebral body receiving radiation doses of 3 Gy or more (VV3 significantly correlated with the changes of nearly all lymphocyte subset counts. Conclusions. SBRT for stage I NSCLC induced significant immune suppression, and the decrease of lymphocyte subset counts may be associated with exposure of the vertebral bone marrow.

  13. Inter- and intrafractional movement of the tumour in extracranial stereotactic radiotherapy of NSCLC

    DEFF Research Database (Denmark)

    Jensen, Henrik R; Hansen, Olfred; Hjelm-Hansen, Mogens

    2008-01-01

    where given a stereotactic treatment. The patients were scanned with normal and uncoached respiration without use of abdominal compression. Each patient had CT-scans performed at four occasions throughout the treatment: As part of the CT-simulation and before the three radiotherapy treatments. At every...... frame were LR: 1.5 mm, AP: 1.1 mm and CC: 1.7 mm (1 SD). DISCUSSION AND CONCLUSIONS: Consecutive CT scans can be used to evaluate the respiration induced tumour movement. For patients immobilized in a stereotactic body frame, large movements of the tumour are rarely seen within the lung...

  14. Stereotactic radiosurgery with an upper partial denture

    International Nuclear Information System (INIS)

    Tayama, Shusaku; Kunieda, Etsuo; Takeda, Atsushi; Takeda, Toshiaki; Oku, Yohei

    2009-01-01

    A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed. (author)

  15. Evaluating proton stereotactic body radiotherapy to reduce chest wall dose in the treatment of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Welsh, James, E-mail: jwelsh@mdanderson.org [Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Amini, Arya [Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, TX (United States); UC Irvine School of Medicine, Irvine, CA (United States); Ciura, Katherine; Nguyen, Ngoc; Palmer, Matt [Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Soh, Hendrick [Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Department of Radiation Physics, The University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Allen, Pamela K.; Paolini, Michael; Liao, Zhongxing [Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Bluett, Jaques; Mohan, Radhe [Department of Radiation Physics, The University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Gomez, Daniel; Cox, James D.; Komaki, Ritsuko; Chang, Joe Y. [Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, TX (United States)

    2013-01-01

    Stereotactic body radiotherapy (SBRT) can produce excellent local control of several types of solid tumor; however, toxicity to nearby critical structures is a concern. We found previously that in SBRT for lung cancer, the chest wall (CW) volume receiving 20, 30, or 40 Gy (V{sub 20}, V{sub 30}, or V{sub 40}) was linked with the development of neuropathy. Here we sought to determine whether the dosimetric advantages of protons could produce lower CW doses than traditional photon-based SBRT. We searched an institutional database to identify patients treated with photon SBRT for lung cancer with tumors within < 2.5 cm of the CW. We found 260 cases; of these, chronic grade ≥ 2 CW pain was identified in 23 patients. We then selected 10 representative patients from this group and generated proton SBRT treatment plans, using the identical dose of 50 Gy in 4 fractions, and assessed potential differences in CW dose between the 2 plans. The proton SBRT plans reduced the CW doses at all dose levels measured. The median CW V{sub 20} was 364.0 cm{sup 3} and 160.0 cm{sup 3} (p < 0.0001), V{sub 30} was 144.6 cm{sup 3}vs 77.0 cm{sup 3} (p = 0.0012), V{sub 35} was 93.9 cm{sup 3}vs 57.9 cm{sup 3} (p = 0.005), V{sub 40} was 66.5 cm{sup 3}vs 45.4 cm{sup 3} (p = 0.0112), and mean lung dose was 5.9 Gy vs 3.8 Gy (p = 0.0001) for photons and protons, respectively. Coverage of the planning target volume (PTV) was comparable between the 2 sets of plans (96.4% for photons and 97% for protons). From a dosimetric standpoint, proton SBRT can achieve the same coverage of the PTV while significantly reducing the dose to the CW and lung relative to photon SBRT and therefore may be beneficial for the treatment of lesions closer to critical structures.

  16. Reirradiation of recurrent node-positive non-small cell lung cancer after previous stereotactic radiotherapy for stage I disease. A multi-institutional treatment recommendation

    International Nuclear Information System (INIS)

    Nieder, Carsten; Ruysscher, Dirk de; Gaspar, Laurie E.; Guckenberger, Matthias; Mehta, Minesh P.; Cheung, Patrick; Sahgal, Arjun

    2017-01-01

    Practice guidelines have been developed for early-stage and locally advanced non-small cell lung cancer (NSCLC). However, many common clinical scenarios still require individualized decision making. This is true for locoregional relapse after initial stereotactic radiotherapy (stereotactic body radiation therapy or stereotactic ablative radiotherapy; SBRT or SABR), an increasingly utilized curative treatment option for stage I NSCLC. A consortium of expert radiation oncologists was established with the aim of providing treatment recommendations. In this scenario, a case was distributed to six radiation oncologists who provided their institutions' treatment recommendations. In this case, a patient developed local and mediastinal relapse after SABR (45 Gy, 3 fractions), comparable to the tumor burden in de novo stage IIIA NSCLC. Treatment recommendations were tabulated and a consensus conclusion was developed. Three institutions recommended evaluation for surgery. If the patient was not a surgical candidate, and/or refused surgery, definitive chemoradiation was recommended, including retreating the primary to full dose. European participants were more in favor of a non-surgical approach. None of the participants were reluctant to prescribe reirradiation, but two institutions prescribed doses lower than 60 Gy. Platinum-based doublets together with intensity-modulated radiotherapy were preferred. The institutional recommendations reflect the questions and uncertainties discussed in current stage III guidelines. All institutions agreed that previous SABR is not a contraindication for salvage chemoradiation. In the absence of high-quality prospective trials for recurrent NSCLC, all treatment options recommended in current guidelines for stage III disease can be considered in clinical scenarios such as this. (orig.) [de

  17. A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals

    International Nuclear Information System (INIS)

    Woerner, Andrew; Roeske, John C.; Harkenrider, Matthew M.; Campana, Maria; Surucu, Murat; Fan, John; Aydogan, Bulent; Koshy, Matthew; Laureckas, Robert; Vali, Faisal

    2015-01-01

    Purpose: A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. Methods: A total of 300 patients receiving lung SBRT treatments in four different institutions were retrospectively reviewed. The treatments were delivered using Linac based SBRT (160 patients) or image guided robotic radiosurgery (140). Most tumors were located peripherally (250/300). Median fractional doses and ranges were 18 Gy (8–20 Gy), 12 Gy (6–15 Gy), and 10 Gy (5–12 Gy) for three, four, and five fraction treatments, respectively. The following planning criteria derived from RTOG trials and the literature were used to evaluate the treatment plans: planning target volumes, PTV_V _1_0_0 ≥ 95% and PTV_V _9_5 ≥ 99%; conformality indices, CI_1_0_0_% < 1.2 and CI_5_0_% range of 2.9–5.9 dependent on PTV; total lung-ITV: V_2_0_G_y < 10%, V_1_2_._5_G_y < 15%, and V_5_G_y < 37%; contralateral lung V_5_G_y < 26%; and maximum doses for spinal cord, esophagus, trachea/bronchus, and heart and great vessels. Populations were grouped by number of fractions, and dosimetric criteria satisfaction rates (CSRs) were reported. Results: Five fraction regimens were the most common lung SBRT fractionation (46%). The median PTV was 27.2 cm"3 (range: 3.8–419.5 cm"3). For all plans: mean PTV_V _1_0_0 was 94.5% (±5.6%, planning CSR: 69.8%), mean PTV_V _9_5 was 98.1% (±4.1%, CSR: 69.5%), mean CI_1_0_0_% was 1.14 (±0.21, CSR: 79.1%, and 16.5% within minor deviation), and mean CI_5_0_% was 5.63 (±2.8, CSR: 33.0%, and 28.0% within minor deviation). When comparing plans based on location, peripherally located tumors displayed higher PTV_V _1_0_0 and PTV_V _9_5 CSR (71.5% and 71.9%, respectively) than centrally located tumors (61.2% and 57.1%, respectively). Overall, the planning criteria were met for all the

  18. A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals

    Energy Technology Data Exchange (ETDEWEB)

    Woerner, Andrew; Roeske, John C.; Harkenrider, Matthew M.; Campana, Maria; Surucu, Murat, E-mail: msurucu@lumc.edu [Loyola University Medical Center, Maywood, Illinois 60153 (United States); Fan, John [Edward Cancer Center, Naperville, Illinois 60540 (United States); Aydogan, Bulent; Koshy, Matthew [Department of Radiation Oncology, University of Illinois at Chicago, Chicago, Illinois 60612 (United States); Laureckas, Robert; Vali, Faisal [Advocate Christ Medical Center, Oak Lawn, Illinois 60453 (United States)

    2015-08-15

    Purpose: A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. Methods: A total of 300 patients receiving lung SBRT treatments in four different institutions were retrospectively reviewed. The treatments were delivered using Linac based SBRT (160 patients) or image guided robotic radiosurgery (140). Most tumors were located peripherally (250/300). Median fractional doses and ranges were 18 Gy (8–20 Gy), 12 Gy (6–15 Gy), and 10 Gy (5–12 Gy) for three, four, and five fraction treatments, respectively. The following planning criteria derived from RTOG trials and the literature were used to evaluate the treatment plans: planning target volumes, PTV{sub V} {sub 100} ≥ 95% and PTV{sub V} {sub 95} ≥ 99%; conformality indices, CI{sub 100%} < 1.2 and CI{sub 50%} range of 2.9–5.9 dependent on PTV; total lung-ITV: V{sub 20Gy} < 10%, V{sub 12.5Gy} < 15%, and V{sub 5Gy} < 37%; contralateral lung V{sub 5Gy} < 26%; and maximum doses for spinal cord, esophagus, trachea/bronchus, and heart and great vessels. Populations were grouped by number of fractions, and dosimetric criteria satisfaction rates (CSRs) were reported. Results: Five fraction regimens were the most common lung SBRT fractionation (46%). The median PTV was 27.2 cm{sup 3} (range: 3.8–419.5 cm{sup 3}). For all plans: mean PTV{sub V} {sub 100} was 94.5% (±5.6%, planning CSR: 69.8%), mean PTV{sub V} {sub 95} was 98.1% (±4.1%, CSR: 69.5%), mean CI{sub 100%} was 1.14 (±0.21, CSR: 79.1%, and 16.5% within minor deviation), and mean CI{sub 50%} was 5.63 (±2.8, CSR: 33.0%, and 28.0% within minor deviation). When comparing plans based on location, peripherally located tumors displayed higher PTV{sub V} {sub 100} and PTV{sub V} {sub 95} CSR (71.5% and 71.9%, respectively) than centrally located tumors (61

  19. Fraction-variant beam orientation optimization for non-coplanar IMRT

    Science.gov (United States)

    O'Connor, Daniel; Yu, Victoria; Nguyen, Dan; Ruan, Dan; Sheng, Ke

    2018-02-01

    Conventional beam orientation optimization (BOO) algorithms for IMRT assume that the same set of beam angles is used for all treatment fractions. In this paper we present a BOO formulation based on group sparsity that simultaneously optimizes non-coplanar beam angles for all fractions, yielding a fraction-variant (FV) treatment plan. Beam angles are selected by solving a multi-fraction fluence map optimization problem involving 500-700 candidate beams per fraction, with an additional group sparsity term that encourages most candidate beams to be inactive. The optimization problem is solved using the fast iterative shrinkage-thresholding algorithm. Our FV BOO algorithm is used to create five-fraction treatment plans for digital phantom, prostate, and lung cases as well as a 30-fraction plan for a head and neck case. A homogeneous PTV dose coverage is maintained in all fractions. The treatment plans are compared with fraction-invariant plans that use a fixed set of beam angles for all fractions. The FV plans reduced OAR mean dose and D 2 values on average by 3.3% and 3.8% of the prescription dose, respectively. Notably, mean OAR dose was reduced by 14.3% of prescription dose (rectum), 11.6% (penile bulb), 10.7% (seminal vesicle), 5.5% (right femur), 3.5% (bladder), 4.0% (normal left lung), 15.5% (cochleas), and 5.2% (chiasm). D 2 was reduced by 14.9% of prescription dose (right femur), 8.2% (penile bulb), 12.7% (proximal bronchus), 4.1% (normal left lung), 15.2% (cochleas), 10.1% (orbits), 9.1% (chiasm), 8.7% (brainstem), and 7.1% (parotids). Meanwhile, PTV homogeneity defined as D 95/D 5 improved from .92 to .95 (digital phantom), from .95 to .98 (prostate case), and from .94 to .97 (lung case), and remained constant for the head and neck case. Moreover, the FV plans are dosimetrically similar to conventional plans that use twice as many beams per fraction. Thus, FV BOO offers the potential to reduce delivery time for non-coplanar IMRT.

  20. SU-F-BRD-15: The Impact of Dose Calculation Algorithm and Hounsfield Units Conversion Tables On Plan Dosimetry for Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Kuo, L; Yorke, E; Lim, S; Mechalakos, J; Rimner, A [Memorial Sloan-Kettering Cancer Center, NY, NY (United States)

    2014-06-15

    Purpose: To assess dosimetric differences in IMRT lung stereotactic body radiotherapy (SBRT) plans calculated with Varian AAA and Acuros (AXB) and with vendor-supplied (V) versus in-house (IH) measured Hounsfield units (HU) to mass and HU to electron density conversion tables. Methods: In-house conversion tables were measured using Gammex 472 density-plug phantom. IMRT plans (6 MV, Varian TrueBeam, 6–9 coplanar fields) meeting departmental coverage and normal tissue constraints were retrospectively generated for 10 lung SBRT cases using Eclipse Vn 10.0.28 AAA with in-house tables (AAA/IH). Using these monitor units and MLC sequences, plans were recalculated with AAA and vendor tables (AAA/V) and with AXB with both tables (AXB/IH and AXB/V). Ratios to corresponding AAA/IH values were calculated for PTV D95, D01, D99, mean-dose, total and ipsilateral lung V20 and chestwall V30. Statistical significance of differences was judged by Wilcoxon Signed Rank Test (p<0.05). Results: For HU<−400 the vendor HU-mass density table was notably below the IH table. PTV D95 ratios to AAA/IH, averaged over all patients, are 0.963±0.073 (p=0.508), 0.914±0.126 (p=0.011), and 0.998±0.001 (p=0.005) for AXB/IH, AXB/V and AAA/V respectively. Total lung V20 ratios are 1.006±0.046 (p=0.386), 0.975±0.080 (p=0.514) and 0.998±0.002 (p=0.007); ipsilateral lung V20 ratios are 1.008±0.041(p=0.284), 0.977±0.076 (p=0.443), and 0.998±0.018 (p=0.005) for AXB/IH, AXB/V and AAA/V respectively. In 7 cases, ratios to AAA/IH were within ± 5% for all indices studied. For 3 cases characterized by very low lung density and small PTV (19.99±8.09 c.c.), PTV D95 ratio for AXB/V ranged from 67.4% to 85.9%, AXB/IH D95 ratio ranged from 81.6% to 93.4%; there were large differences in other studied indices. Conclusion: For AXB users, careful attention to HU conversion tables is important, as they can significantly impact AXB (but not AAA) lung SBRT plans. Algorithm selection is also important for

  1. Spatial and dose–response analysis of fibrotic lung changes after stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Vinogradskiy, Yevegeniy; Diot, Quentin; Kavanagh, Brian; Schefter, Tracey; Gaspar, Laurie; Miften, Moyed

    2013-01-01

    Purpose: Stereotactic body radiation therapy (SBRT) is becoming the standard of care for early stage nonoperable lung cancers. Accurate dose–response modeling is challenging for SBRT because of the decreased number of clinical toxicity events. As a surrogate for a clinical toxicity endpoint, studies have proposed to use radiographic changes in follow up computed tomography (CT) scans to evaluate lung SBRT normal tissue effects. The purpose of the current study was to use local fibrotic lung regions to spatially and dosimetrically evaluate lung changes in patients that underwent SBRT.Methods: Forty seven SBRT patients treated at our institution from 2003 to 2009 were used for the current study. Our patient cohort had a total of 148 follow up CT scans ranging from 3 to 48 months post-therapy. Post-treatment scans were binned into intervals of 3, 6, 12, 18, 24, 30, and 36 months after the completion of treatment. Deformable image registration was used to align the follow up CT scans with the pretreatment CT and dose distribution. Areas of visible fibrotic changes were contoured. The centroid of each gross tumor volume (GTV) and contoured fibrosis volume was calculated and the fibrosis volume location and movement (magnitude and direction) relative to the GTV and 30 Gy isodose centroid were analyzed. To perform a dose–response analysis, each voxel in the fibrosis volume was sorted into 10 Gy dose bins and the average CT number value for each dose bin was calculated. Dose–response curves were generated by plotting the CT number as a function of dose bin and time posttherapy.Results: Both fibrosis and GTV centroids were concentrated in the upper third of the lung. The average radial movement of fibrosis centroids relative to the GTV centroids was 2.6 cm with movement greater than 5 cm occurring in 11% of patients. Evaluating dose–response curves revealed an overall trend of increasing CT number as a function of dose. The authors observed a CT number plateau at

  2. An analysis of patient positioning during stereotactic lung radiotherapy performed without rigid external immobilization.

    Science.gov (United States)

    Dahele, Max; Verbakel, Wilko; Cuijpers, Johan; Slotman, Ben; Senan, Suresh

    2012-07-01

    Intra-fraction patient motion is incompletely understood and the optimum amount of support or immobilization during stereotactic body radiotherapy (SBRT) is unclear. Rigid immobilization is often advocated, but motion still occurs. In contrast, we deliver the vast majority of SBRT using simple supporting devices, simultaneously emphasizing comfort, frequent position checks and progressive reduction in treatment times. We report spine stability during lung SBRT. Patients lie on a thin mattress with arms supported above their head and below-knee support. Stereoscopic spine X-rays before and after fraction delivery identified motion in three translational and three rotational directions. Images from 109 fractions in 30 patients resulted in 327 translational and 327 rotational pre- and post-fraction comparisons. Mean RapidArc® delivery time for variable fraction dose was 4.2 min (SD=1.4). 92% and 97% of translational and rotational differences were ≤1 mm and ≤1° in any direction and 98% of translational differences were ≤1.5mm. Mean vertical, longitudinal and lateral motion was 0mm (SD=0.4), 0mm (0.6) and 0mm (0.6). 84% and 94% of the 109 fractions were delivered with ≤1 and ≤1.5mm translation in all three directions and 93% with ≤1° of rotation. Two patients accounted for 10/17 fractions with >1mm translational motion. Based on pre and post-fraction X-ray imaging during fast lung SBRT, simple support devices can result in spine stability that is comparable to that reported with rigid external immobilization. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Early detection of lung cancer recurrence after stereotactic ablative radiation therapy: radiomics system design

    Science.gov (United States)

    Dammak, Salma; Palma, David; Mattonen, Sarah; Senan, Suresh; Ward, Aaron D.

    2018-02-01

    Stereotactic ablative radiotherapy (SABR) is the standard treatment recommendation for Stage I non-small cell lung cancer (NSCLC) patients who are inoperable or who refuse surgery. This option is well tolerated by even unfit patients and has a low recurrence risk post-treatment. However, SABR induces changes in the lung parenchyma that can appear similar to those of recurrence, and the difference between the two at an early follow-up time point is not easily distinguishable for an expert physician. We hypothesized that a radiomics signature derived from standard-of-care computed tomography (CT) imaging can detect cancer recurrence within six months of SABR treatment. This study reports on the design phase of our work, with external validation planned in future work. In this study, we performed cross-validation experiments with four feature selection approaches and seven classifiers on an 81-patient data set. We extracted 104 radiomics features from the consolidative and the peri-consolidative regions on the follow-up CT scans. The best results were achieved using the sum of estimated Mahalanobis distances (Maha) for supervised forward feature selection and a trainable automatic radial basis support vector classifier (RBSVC). This system produced an area under the receiver operating characteristic curve (AUC) of 0.84, an error rate of 16.4%, a false negative rate of 12.7%, and a false positive rate of 20.0% for leaveone patient out cross-validation. This suggests that once validated on an external data set, radiomics could reliably detect post-SABR recurrence and form the basis of a tool assisting physicians in making salvage treatment decisions.

  4. Usefulness of radiation treatment planning allpied respiration factor for streotatic body radiation therapy in the lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sung Pil; Kim, Tae Hyung; So, Woon Young; Back, Geum Mun [Dept. of Medical Health Science, Graduate School, Kangwon National University, Chuncheon (Korea, Republic of)

    2016-12-15

    We are evaluated the usefulness of radiation treatment planning applied respiration factor for stereotactic body radiation therapy in the lung cancer. Four dimensional computed tomography images were obtained in 10 patients with lung cancer. The radiation treatment plans were established total lung volume according to respiration images (new method) and conventional method. We was analyzed in the lung volume, radiation absorbed dose of lung and main organs (ribs, tracheobronchus, esophagus, spinal cord) around the tumor, respectively. We were confirmed that lung volume and radiation absorbed dose of lung and main organs around the tumor deference according to applied respiration. In conclusion, radiation treatment planning applied respiration factor seems to be useful for stereotactic body radiation therapy in the lung cancer.

  5. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Tsuruta, Yusuke; Nakata, Manabu; Higashimura, Kyoji; Nakamura, Mitsuhiro; Matsuo, Yukinori; Monzen, Hajime; Mizowaki, Takashi; Hiraoka, Masahiro

    2014-01-01

    Purpose: To compare the dosimetric performance of Acuros XB (AXB), anisotropic analytical algorithm (AAA), and x-ray voxel Monte Carlo (XVMC) in heterogeneous phantoms and lung stereotactic body radiotherapy (SBRT) plans. Methods: Water- and lung-equivalent phantoms were combined to evaluate the percentage depth dose and dose profile. The radiation treatment machine Novalis (BrainLab AG, Feldkirchen, Germany) with an x-ray beam energy of 6 MV was used to calculate the doses in the composite phantom at a source-to-surface distance of 100 cm with a gantry angle of 0°. Subsequently, the clinical lung SBRT plans for the 26 consecutive patients were transferred from the iPlan (ver. 4.1; BrainLab AG) to the Eclipse treatment planning systems (ver. 11.0.3; Varian Medical Systems, Palo Alto, CA). The doses were then recalculated with AXB and AAA while maintaining the XVMC-calculated monitor units and beam arrangement. Then the dose-volumetric data obtained using the three different radiation dose calculation algorithms were compared. Results: The results from AXB and XVMC agreed with measurements within ±3.0% for the lung-equivalent phantom with a 6 × 6 cm 2 field size, whereas AAA values were higher than measurements in the heterogeneous zone and near the boundary, with the greatest difference being 4.1%. AXB and XVMC agreed well with measurements in terms of the profile shape at the boundary of the heterogeneous zone. For the lung SBRT plans, AXB yielded lower values than XVMC in terms of the maximum doses of ITV and PTV; however, the differences were within ±3.0%. In addition to the dose-volumetric data, the dose distribution analysis showed that AXB yielded dose distribution calculations that were closer to those with XVMC than did AAA. Means ± standard deviation of the computation time was 221.6 ± 53.1 s (range, 124–358 s), 66.1 ± 16.0 s (range, 42–94 s), and 6.7 ± 1.1 s (range, 5–9 s) for XVMC, AXB, and AAA, respectively. Conclusions: In the phantom

  6. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer.

    Science.gov (United States)

    Tsuruta, Yusuke; Nakata, Manabu; Nakamura, Mitsuhiro; Matsuo, Yukinori; Higashimura, Kyoji; Monzen, Hajime; Mizowaki, Takashi; Hiraoka, Masahiro

    2014-08-01

    To compare the dosimetric performance of Acuros XB (AXB), anisotropic analytical algorithm (AAA), and x-ray voxel Monte Carlo (XVMC) in heterogeneous phantoms and lung stereotactic body radiotherapy (SBRT) plans. Water- and lung-equivalent phantoms were combined to evaluate the percentage depth dose and dose profile. The radiation treatment machine Novalis (BrainLab AG, Feldkirchen, Germany) with an x-ray beam energy of 6 MV was used to calculate the doses in the composite phantom at a source-to-surface distance of 100 cm with a gantry angle of 0°. Subsequently, the clinical lung SBRT plans for the 26 consecutive patients were transferred from the iPlan (ver. 4.1; BrainLab AG) to the Eclipse treatment planning systems (ver. 11.0.3; Varian Medical Systems, Palo Alto, CA). The doses were then recalculated with AXB and AAA while maintaining the XVMC-calculated monitor units and beam arrangement. Then the dose-volumetric data obtained using the three different radiation dose calculation algorithms were compared. The results from AXB and XVMC agreed with measurements within ± 3.0% for the lung-equivalent phantom with a 6 × 6 cm(2) field size, whereas AAA values were higher than measurements in the heterogeneous zone and near the boundary, with the greatest difference being 4.1%. AXB and XVMC agreed well with measurements in terms of the profile shape at the boundary of the heterogeneous zone. For the lung SBRT plans, AXB yielded lower values than XVMC in terms of the maximum doses of ITV and PTV; however, the differences were within ± 3.0%. In addition to the dose-volumetric data, the dose distribution analysis showed that AXB yielded dose distribution calculations that were closer to those with XVMC than did AAA. Means ± standard deviation of the computation time was 221.6 ± 53.1 s (range, 124-358 s), 66.1 ± 16.0 s (range, 42-94 s), and 6.7 ± 1.1 s (range, 5-9 s) for XVMC, AXB, and AAA, respectively. In the phantom evaluations, AXB and XVMC agreed better with

  7. Comparative Cost-Effectiveness of Stereotactic Body Radiation Therapy Versus Intensity-Modulated and Proton Radiation Therapy for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Parthan, Anju; Pruttivarasin, Narin; Davies, Diane; Taylor, Douglas C. A.; Pawar, Vivek; Bijlani, Akash; Lich, Kristen Hassmiller; Chen, Ronald C.

    2012-01-01

    Objective: To determine the cost-effectiveness of several external beam radiation treatment modalities for the treatment of patients with localized prostate cancer. Methods: A lifetime Markov model incorporated the probabilities of experiencing treatment-related long-term toxicity or death. Toxicity probabilities were derived from published sources using meta-analytical techniques. Utilities and costs in the model were obtained from publicly available secondary sources. The model calculated quality-adjusted life expectancy and expected lifetime cost per patient, and derived ratios of incremental cost per quality-adjusted life year (QALY) gained between treatments. Analyses were conducted from both payer and societal perspectives. One-way and probabilistic sensitivity analyses were performed. Results: Compared to intensity-modulated radiation therapy (IMRT) and proton beam therapy (PT), stereotactic body radiation therapy (SBRT) was less costly and resulted in more QALYs. Sensitivity analyses showed that the conclusions in the base-case scenario were robust with respect to variations in toxicity and cost parameters consistent with available evidence. At a threshold of $50,000/QALY, SBRT was cost-effective in 75% and 94% of probabilistic simulations compared to IMRT and PT, respectively, from a payer perspective. From a societal perspective, SBRT was cost-effective in 75% and 96% of simulations compared to IMRT and PT, respectively, at a threshold of $50,000/QALY. In threshold analyses, SBRT was less expensive with better outcomes compared to IMRT at toxicity rates 23% greater than the SBRT base-case rates. Conclusion: Based on the assumption that each treatment modality results in equivalent long-term efficacy, SBRT is a cost-effective strategy resulting in improved quality-adjusted survival compared to IMRT and PT for the treatment of localized prostate cancer.

  8. TH-A-9A-03: Dosimetric Effect of Rotational Errors for Lung Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Lee, J; Kim, H; Park, J; Kim, J; Kim, H; Ye, S

    2014-01-01

    Purpose: To evaluate the dosimetric effects on target volume and organs at risk (OARs) due to roll rotational errors in treatment setup of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: There were a total of 23 volumetric modulated arc therapy (VMAT) plans for lung SBRT examined in this retrospective study. Each CT image of VMAT plans was intentionally rotated by ±1°, ±2°, and ±3° to simulate roll rotational setup errors. The axis of rotation was set at the center of T-spine. The target volume and OARs in the rotated CT images were re-defined by deformable registration of original contours. The dose distributions on each set of rotated images were re-calculated to cover the planning target volume (PTV) with the prescription dose before and after the couch translational correction. The dose-volumetric changes of PTVs and spinal cords were analyzed. Results: The differences in D95% of PTVs by −3°, −2°, −1°, 1°, 2°, and 3° roll rotations before the couch translational correction were on average −11.3±11.4%, −5.46±7.24%, −1.11±1.38% −3.34±3.97%, −9.64±10.3%, and −16.3±14.7%, respectively. After the couch translational correction, those values were −0.195±0.544%, −0.159±0.391%, −0.188±0.262%, −0.310±0.270%, −0.407±0.331%, and −0.433±0.401%, respectively. The maximum dose difference of spinal cord among the 23 plans even after the couch translational correction was 25.9% at −3° rotation. Conclusions: Roll rotational setup errors in lung SBRT significantly influenced the coverage of target volume using VMAT technique. This could be in part compensated by the translational couch correction. However, in spite of the translational correction, the delivered doses to the spinal cord could be more than the calculated doses. Therefore if rotational setup errors exist during lung SBRT using VMAT technique, the rotational correction would rather be considered to prevent over-irradiation of normal

  9. Forcing lateral electron disequilibrium to spare lung tissue: a novel technique for stereotactic body radiation therapy of lung cancer

    International Nuclear Information System (INIS)

    Disher, Brandon; Hajdok, George; Gaede, Stewart; Mulligan, Matthew; Battista, Jerry J

    2013-01-01

    Stereotactic body radiation therapy (SBRT) has quickly become a preferred treatment option for early-stage lung cancer patients who are ineligible for surgery. This technique uses tightly conformed megavoltage (MV) x-ray beams to irradiate a tumour with ablative doses in only a few treatment fractions. Small high energy x-ray fields can cause lateral electron disequilibrium (LED) to occur within low density media, which can reduce tumour dose. These dose effects may be challenging to predict using analytic dose calculation algorithms, especially at higher beam energies. As a result, previous authors have suggested using low energy photons ( 5 × 5 cm 2 ) for lung cancer patients to avoid the negative dosimetric effects of LED. In this work, we propose a new form of SBRT, described as LED-optimized SBRT (LED-SBRT), which utilizes radiotherapy (RT) parameters designed to cause LED to advantage. It will be shown that LED-SBRT creates enhanced dose gradients at the tumour/lung interface, which can be used to manipulate tumour dose, and/or normal lung dose. To demonstrate the potential benefits of LED-SBRT, the DOSXYZnrc (National Research Council of Canada, Ottawa, ON) Monte Carlo (MC) software was used to calculate dose within a cylindrical phantom and a typical lung patient. 6 MV or 18 MV x-ray fields were focused onto a small tumour volume (diameter ∼1 cm). For the phantom, square fields of 1 × 1 cm 2 , 3 × 3 cm 2 , or 5 × 5 cm 2 were applied. However, in the patient, 3 × 1 cm 2 , 3 × 2 cm 2 , 3 × 2.5 cm 2 , or 3 × 3 cm 2 field sizes were used in simulations to assure target coverage in the superior–inferior direction. To mimic a 180° SBRT arc in the (symmetric) phantom, a single beam profile was calculated, rotated, and beams were summed at 1° segments to accumulate an arc dose distribution. For the patient, a 360° arc was modelled with 36 equally weighted (and spaced) fields focused on the tumour centre. A planning target volume (PTV) was generated

  10. Prediction of Chest Wall Toxicity From Lung Stereotactic Body Radiotherapy (SBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Stephans, Kevin L., E-mail: stephak@ccf.org [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, OH (United States); Djemil, Toufik; Tendulkar, Rahul D. [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, OH (United States); Robinson, Cliff G. [Department of Radiation Oncology, Siteman Cancer Center, Washington University, St Louis, MO (United States); Reddy, Chandana A.; Videtic, Gregory M.M. [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, OH (United States)

    2012-02-01

    Purpose: To determine patient, tumor, and treatment factors related to the development of late chest wall toxicity after lung stereotactic body radiotherapy (SBRT). Methods and Materials: We reviewed a registry of 134 patients treated with lung SBRT to 60 Gy in 3 fractions who had greater than 1 year of clinical follow-up and no history of multiple treatments to the same lobe (n = 48). Patients were treated as per Radiation Therapy Oncology Group Protocol 0236 without specific chest wall avoidance criteria. The chest wall was retrospectively contoured. Thirty-two lesions measured less than 3 cm, and sixteen measured 3 to 5 cm. The median planning target volume was 29 cm{sup 3}. Results: With a median follow-up of 18.8 months, 10 patients had late symptomatic chest wall toxicity (4 Grade 1 and 6 Grade 2) at a median of 8.8 months after SBRT. No patient characteristics (age, diabetes, hypertension, peripheral vascular disease, or body mass index) were predictive for toxicity, whereas there was a trend for continued smoking (p = 0.066; odds ratio [OR], 4.4). Greatest single tumor dimension (p = 0.047; OR, 2.63) and planning target volume (p = 0.040; OR, 1.04) were correlated with toxicity, whereas distance from tumor edge to chest wall and gross tumor volume did not reach statistical significance. Volumes of chest wall receiving 30 Gy (V30) through 70 Gy (V70) were all highly significant, although this correlation weakened for V65 and V70 and maximum chest wall point dose only trended to significance (p = 0.06). On multivariate analysis, tumor volume was no longer correlated with toxicity and only V30 through V60 remained statistically significant. Conclusions: Tumor size and chest wall dosimetry are correlated to late chest wall toxicity. Only chest wall V30 through V60 remained significant on multivariate analysis. Restricting V30 to 30 cm{sup 3} or less and V60 to 3 cm{sup 3} or less should result in a 10% to 15% risk of late chest wall toxicity or lower.

  11. Megavoltage conebeam CT cine as final verification of treatment plan in lung stereotactic body radiotherapy.

    Science.gov (United States)

    Kudithipudi, Vijay; Gayou, Olivier; Colonias, Athanasios

    2016-06-01

    To analyse the clinical impact of megavoltage conebeam computed tomography (MV-CBCT) cine on internal target volume (ITV) coverage in lung stereotactic body radiotherapy (SBRT). One hundred and six patients received lung SBRT. All underwent 4D computed tomography simulation followed by treatment via image guided 3D conformal or intensity modulated radiation. Prior to SBRT, all patients underwent MV-CBCT cine, in which raw projections are displayed as beam's-eye-view fluoroscopic series with the planning target volume (PTV) projected onto each image, enabling verification of tumour motion relative to the PTV and assessment of adequacy of treatment margin. Megavoltage conebeam computed tomography cine was completed 1-2 days prior to SBRT. Four patients (3.8%) had insufficient ITV coverage inferiorly at cine review. All four plans were changed by adding 5 mm on the PTV margin inferiorly. The mean change in PTV volumes was 3.9 cubic centimetres (cc) (range 1.85-6.32 cc). Repeat cine was performed after plan modification to ensure adequate PTV coverage in the modified plans. PTV margin was adequate in the majority of patients with this technique. MV-CBCT cine did show insufficient coverage in a small subset of patients. Insufficient PTV margins may be a function of 4D CT simulation inadequacies or deficiencies in visualizing the ITV inferior border in the full-inhale phase. MV-CBCT cine is a valuable tool for final verification of PTV margins. © 2016 The Royal Australian and New Zealand College of Radiologists.

  12. Salvage surgery for local failures after stereotactic ablative radiotherapy for early stage non-small cell lung cancer

    International Nuclear Information System (INIS)

    Verstegen, Naomi E.; Maat, Alexander P. W. M.; Lagerwaard, Frank J.; Paul, Marinus A.; Versteegh, Michel I; Joosten, Joris J.; Lastdrager, Willem; Smit, Egbert F.; Slotman, Ben J.; Nuyttens, Joost J. M. E.; Senan, Suresh

    2016-01-01

    The literature on surgical salvage, i.e. lung resections in patients who develop a local recurrence following stereotactic ablative radiotherapy (SABR), is limited. We describe our experience with salvage surgery in nine patients who developed a local recurrence following SABR for early stage non-small cell lung cancer (NSCLC). Patients who underwent surgical salvage for a local recurrence following SABR for NSCLC were identified from two Dutch institutional databases. Complications were scored using the Dindo-Clavien-classification. Nine patients who underwent surgery for a local recurrence were identified. Median time to local recurrence was 22 months. Recurrences were diagnosed with CT- and/or 18FDG-PET-imaging, with four patients also having a pre-surgical pathological diagnosis. Extensive adhesions were observed during two resections, requiring conversion from a thoracoscopic procedure to thoracotomy during one of these procedures. Three patients experienced complications post-surgery; grade 2 (N = 2) and grade 3a (N = 1), respectively. All resection specimens showed viable tumor cells. Median length of hospital stay was 8 days (range 5–15 days) and 30-day mortality was 0 %. Lymph node dissection revealed mediastinal metastases in 3 patients, all of whom received adjuvant therapy. Our experience with nine surgical procedures for local recurrences post-SABR revealed two grade IIIa complications, and a 30-day mortality of 0 %, suggesting that salvage surgery can be safely performed after SABR

  13. Dosimetric comparison of standard three-dimensional conformal radiotherapy followed by intensity-modulated radiotherapy boost schedule (sequential IMRT plan) with simultaneous integrated boost-IMRT (SIB IMRT) treatment plan in patients with localized carcinoma prostate.

    Science.gov (United States)

    Bansal, A; Kapoor, R; Singh, S K; Kumar, N; Oinam, A S; Sharma, S C

    2012-07-01

    DOSIMETERIC AND RADIOBIOLOGICAL COMPARISON OF TWO RADIATION SCHEDULES IN LOCALIZED CARCINOMA PROSTATE: Standard Three-Dimensional Conformal Radiotherapy (3DCRT) followed by Intensity Modulated Radiotherapy (IMRT) boost (sequential-IMRT) with Simultaneous Integrated Boost IMRT (SIB-IMRT). Thirty patients were enrolled. In all, the target consisted of PTV P + SV (Prostate and seminal vesicles) and PTV LN (lymph nodes) where PTV refers to planning target volume and the critical structures included: bladder, rectum and small bowel. All patients were treated with sequential-IMRT plan, but for dosimetric comparison, SIB-IMRT plan was also created. The prescription dose to PTV P + SV was 74 Gy in both strategies but with different dose per fraction, however, the dose to PTV LN was 50 Gy delivered in 25 fractions over 5 weeks for sequential-IMRT and 54 Gy delivered in 27 fractions over 5.5 weeks for SIB-IMRT. The treatment plans were compared in terms of dose-volume histograms. Also, Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) obtained with the two plans were compared. The volume of rectum receiving 70 Gy or more (V > 70 Gy) was reduced to 18.23% with SIB-IMRT from 22.81% with sequential-IMRT. SIB-IMRT reduced the mean doses to both bladder and rectum by 13% and 17%, respectively, as compared to sequential-IMRT. NTCP of 0.86 ± 0.75% and 0.01 ± 0.02% for the bladder, 5.87 ± 2.58% and 4.31 ± 2.61% for the rectum and 8.83 ± 7.08% and 8.25 ± 7.98% for the bowel was seen with sequential-IMRT and SIB-IMRT plans respectively. For equal PTV coverage, SIB-IMRT markedly reduced doses to critical structures, therefore should be considered as the strategy for dose escalation. SIB-IMRT achieves lesser NTCP than sequential-IMRT.

  14. Stereotactic Body Radiation Therapy for Early-Stage Non-Small-Cell Lung Cancer: The Pattern of Failure Is Distant

    International Nuclear Information System (INIS)

    Bradley, Jeffrey D.; El Naqa, Issam; Drzymala, Robert E.; Trovo, Marco; Jones, Griffin; Denning, Mary Dee

    2010-01-01

    Background: Stereotactic body radiation therapy (SBRT) represents a substantial paradigm shift in the treatment of patients with medically inoperable Stage I/II non-small-cell lung cancer. We reviewed our experience using either three- or five-fraction SBRT for peripheral or central tumors, respectively. Methods and Materials: A total of 91 patients signed an institutional review board-approved consent form, were treated with SBRT, and have had ≥6 months of follow-up. Patients were referred for SBRT because of underlying comorbidities (poor performance status in 31 or poor lung function in 52) or refusal of surgery (8 patients). Of the cancers, 83 were peripheral and eight were central. Peripheral cancers received a mean dose of 18 Gy x three fractions. Cancers within 2 cm of the bronchus, esophagus, or brachial plexus were treated with 9 Gy x five fractions. Results: The median follow-up duration for these patients was 18 months (range, 6-42 months). TNM staging was as follows: 58 patients with T1N0M0, 22 with T2N0M0, 2 with T3N0M0 (chest wall), and 6 with T1N0M1 cancers. The median tumor diameter was 2 cm (range, 1-5 cm). The median forced expiratory volume in 1 s was 46% (range, 17-133%) and the median carbon monoxide diffusing capacity (DLCO) was 49% (range, 15-144%). Two-year local tumor control was achieved in 86% of patients. The predominant pattern of failure was the development of distant metastasis or second lung cancer. The development of distant metastasis was the only significant prognostic factor for overall survival on multivariate analysis. Conclusions: Local tumor control was shown to be high using SBRT for non-small-cell lung cancer. Overall survival is highly coerrelated with the development of distant metastasis.

  15. Clinical results of stereotactic body radiotherapy for Stage I small-cell lung cancer. A single institutional experience

    International Nuclear Information System (INIS)

    Shioyama, Yoshiyuki; Nakamura, Katsumasa; Sasaki, Tomonari; Ohga, Saiji; Yoshitake, Tadamasa; Nonoshita, Takeshi; Asai, Kaori; Terashima, Koutarou; Matsumoto, Keiji; Hirata, Hideki; Honda, Hiroshi

    2013-01-01

    The purpose of this study was to evaluate the treatment outcomes of stereotactic body radiotherapy (SBRT) for Stage I small-cell lung cancer (SCLC). From April 2003 to September 2009, a total of eight patients with Stage I SCLC were treated with SBRT in our institution. In all patients, the lung tumors were proven as SCLC pathologically. The patients' ages were 58-84 years (median: 74). The T-stage of the primary tumor was T1a in two, T1b in two and T2a in four patients. Six of the patients were inoperable because of poor cardiac and/or pulmonary function, and two patients refused surgery. SBRT was given using 7-8 non-coplanar beams with 48 Gy in four fractions. Six of the eight patients received 3-4 cycles of chemotherapy using carboplatin (CBDCA) + etoposide (VP-16) or cisplatin (CDDP) + irinotecan (CPT-11). The follow-up period for all patients was 6-60 months (median: 32). Six patients were still alive without any recurrence. One patient died from this disease and one died from another disease. The overall and disease-specific survival rate at three years was 72% and 86%, respectively. There were no patients with local progression of the lesion targeted by SBRT. Only one patient had nodal recurrence in the mediastinum at 12 months after treatment. The progression-free survival rate was 71%. No Grade 2 or higher SBRT-related toxicities were observed. SBRT plus chemotherapy could be an alternative to surgery with chemotherapy for inoperable patients with Stage I small-cell lung cancer. However, further investigation is needed using a large series of patients. (author)

  16. Esophagus sparing with IMRT in lung tumor irradiation: An EUD-based optimization technique

    International Nuclear Information System (INIS)

    Chapet, Olivier; Thomas, Emma; Kessler, Marc L.; Fraass, Benedick A.; Ten Haken, Randall K.

    2005-01-01

    Purpose: The aim of this study was to evaluate (1) the use of generalized equivalent uniform dose (gEUD) to optimize dose escalation of lung tumors when the esophagus overlaps the planning target volume (PTV) and (2) the potential benefit of further dose escalation in only the part of the PTV that does not overlap the esophagus. Methods and Materials: The treatment-planning computed tomography (CT) scans of patients with primary lung tumors located in different regions of the left and right lung were used for the optimization of beamlet intensity modulated radiation therapy (IMRT) plans. In all cases, the PTV overlapped part of the esophagus. The dose in the PTV was maximized according to 7 different primary cost functions: 2 plans that made use of mean dose (MD) (the reference plan, in which the 95% isodose surface covered the PTV and a second plan that had no constraint on the minimum isodose), 3 plans based on maximizing gEUD for the whole PTV with ever increasing assumptions for tumor aggressiveness, and 2 plans that used different gEUD values in 2 simultaneous, overlapping target volumes (the whole PTV and the PTV minus esophagus). Beam arrangements and NTCP-based costlets for the organs at risk (OARs) were kept identical to the original conformal plan for each case. Regardless of optimization method, the relative ranking of the resulting plans was evaluated in terms of the absence of cold spots within the PTV and the final gEUD computed for the whole PTV. Results: Because the MD-optimized plans lacked a constraint on minimum PTV coverage, they resulted in cold spots that affected approximately 5% of the PTV volume. When optimizing over the whole PTV volume, gEUD-optimized plans resulted in higher equivalent uniform PTV doses than did the reference plan while still maintaining normal-tissue constraints. However, only under the assumption of extremely aggressive tumors could cold spots in the PTV be avoided. Generally, high-level overall results are obtained

  17. Stereotactic Ablative Radiation Therapy as First Local Therapy for Lung Oligometastases From Colorectal Cancer: A Single-Institution Cohort Study

    Energy Technology Data Exchange (ETDEWEB)

    Filippi, Andrea Riccardo, E-mail: andreariccardo.filippi@unito.it [Department of Oncology, Radiation Oncology, University of Torino, Torino (Italy); Badellino, Serena [Department of Oncology, Radiation Oncology, University of Torino, Torino (Italy); Ceccarelli, Manuela [Cancer Epidemiology and CPO Piemonte, Città della Salute e della Scienza, Torino (Italy); Guarneri, Alessia [Radiation Oncology, Città della Salute e della Scienza, Torino (Italy); Franco, Pierfrancesco [Department of Oncology, Radiation Oncology, University of Torino, Torino (Italy); Monagheddu, Chiara [Cancer Epidemiology and CPO Piemonte, Città della Salute e della Scienza, Torino (Italy); Spadi, Rosella [Medical Oncology, Colorectal Cancer Unit, Città della Salute e della Scienza, Torino (Italy); Ragona, Riccardo [Department of Oncology, Radiation Oncology, University of Torino, Torino (Italy); Racca, Patrizia [Medical Oncology, Colorectal Cancer Unit, Città della Salute e della Scienza, Torino (Italy); Ricardi, Umberto [Department of Oncology, Radiation Oncology, University of Torino, Torino (Italy)

    2015-03-01

    Purpose: To estimate stereotactic ablative radiation therapy (SABR) efficacy and its potential role as an alternative to surgery for the treatment of lung metastases from colorectal cancer. Methods and Materials: Forty consecutive patients who received SABR as first local therapy at the time of lung progression were included, from 2004 to 2014. The primary study endpoint was overall survival. Secondary endpoints were progression-free survival and safety. Results: A single nodule was treated in 26 patients (65%), 2 nodules in 10 patients (25%), 3 in 3 patients (7.5%), and 4 in 1 patient (2.5%), for a total of 59 lesions. The median delivered biological effective dose was 96 Gy, in 1 to 8 daily fractions. Median follow-up time was 20 months (range, 3-72 months). Overall survival rates at 1, 2, and 5 years were, respectively, 84%, 73%, and 39%, with 14 patients (35%) dead. Median overall survival was 46 months. Progression occurred in 25 patients (62.5%), at a median interval of 8 months; failure at SABR site was observed in 3 patients (7.5%). Progression-free survival rates were 49% and 27% at 1 and 2 years, respectively. Discussion: The results of this retrospective exploratory analysis suggest safety and efficacy of SABR in patients affected with colorectal cancer lung oligometastases and urge inclusion of SABR in prospective clinical trials.

  18. Stereotactic Ablative Radiation Therapy as First Local Therapy for Lung Oligometastases From Colorectal Cancer: A Single-Institution Cohort Study

    International Nuclear Information System (INIS)

    Filippi, Andrea Riccardo; Badellino, Serena; Ceccarelli, Manuela; Guarneri, Alessia; Franco, Pierfrancesco; Monagheddu, Chiara; Spadi, Rosella; Ragona, Riccardo; Racca, Patrizia; Ricardi, Umberto

    2015-01-01

    Purpose: To estimate stereotactic ablative radiation therapy (SABR) efficacy and its potential role as an alternative to surgery for the treatment of lung metastases from colorectal cancer. Methods and Materials: Forty consecutive patients who received SABR as first local therapy at the time of lung progression were included, from 2004 to 2014. The primary study endpoint was overall survival. Secondary endpoints were progression-free survival and safety. Results: A single nodule was treated in 26 patients (65%), 2 nodules in 10 patients (25%), 3 in 3 patients (7.5%), and 4 in 1 patient (2.5%), for a total of 59 lesions. The median delivered biological effective dose was 96 Gy, in 1 to 8 daily fractions. Median follow-up time was 20 months (range, 3-72 months). Overall survival rates at 1, 2, and 5 years were, respectively, 84%, 73%, and 39%, with 14 patients (35%) dead. Median overall survival was 46 months. Progression occurred in 25 patients (62.5%), at a median interval of 8 months; failure at SABR site was observed in 3 patients (7.5%). Progression-free survival rates were 49% and 27% at 1 and 2 years, respectively. Discussion: The results of this retrospective exploratory analysis suggest safety and efficacy of SABR in patients affected with colorectal cancer lung oligometastases and urge inclusion of SABR in prospective clinical trials

  19. The use of the multislice CT for the determination of respiratory lung tumor movement in stereotactic single-dose irradiation

    International Nuclear Information System (INIS)

    Hof, H.; Herfarth, K.K.; Muenter, M.; Debus, J.; Essig, M.; Wannenmacher, M.

    2003-01-01

    Background: In three-dimensional (3-D) precision high-dose radiation therapy of lung tumors, the exact definition of the planning target volume (PTV) is indispensable. Therefore, the feasibility of a 3-D determination of respiratory lung tumor movements by the use of a multislice CT scanner was investigated. Patients and Methods: The respiratory motion of 21 lung tumors in 20 consecutively treated patients was examined. An abdominal pressure device for the reduction of respiratory movement was used in 14 patients. Two regions of the tumor were each scanned repeatedly at the same table position, showing four simultaneously acquired slices for each cycle. Stereotactic coordinates were determined for one anatomic reference point in each tumor region (Figure 1). The 3-D differences of these coordinates between the sequentially obtained cycles were assessed (Figure 2), and a correlation with the tumor localization was performed. Results: In the craniocaudal (Z-)direction the mean tumor movement was 5.1 mm (standard deviation [SD] 2.4 mm, maximum 10 mm), in the ventrodorsal (Y-)direction 3.1 mm (SD 1.5 mm, maximum 6.7 mm), and in the lateral (X-)direction 2.6 mm (SD 1.4 mm, maximum 5.8 mm; Figures 3 to 5). Inter- and intraindividual differences were present in each direction. With an abdominal pressure device no clinically significant difference between tumors in different locations was seen. Conclusion: The 3-D assessment of lung tumor movements due to breathing is possible by the use of multislice CT. The determination, indispensable to the PTV definition, should be performed individually for several regions, because of the inter- and intraindividual deviations detected. (orig.)

  20. Local Control and Toxicity in a Large Cohort of Central Lung Tumors Treated With Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Modh, Ankit; Rimner, Andreas [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Williams, Eric [Department of Medical Physics Memorial Sloan Kettering Cancer Center, New York, New York (United States); Foster, Amanda; Shah, Mihir [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Shi, Weiji; Zhang, Zhigang [Department of Biostatistics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Gelblum, Daphna Y. [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Rosenzweig, Kenneth E. [Department of Radiation Oncology, Mount Sinai Medical Center, New York, New York (United States); Yorke, Ellen D.; Jackson, Andrew [Department of Medical Physics Memorial Sloan Kettering Cancer Center, New York, New York (United States); Wu, Abraham J., E-mail: wua@mskcc.org [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States)

    2014-12-01

    Purpose: Stereotactic body radiation therapy (SBRT) in central lung tumors has been associated with higher rates of severe toxicity. We sought to evaluate toxicity and local control in a large cohort and to identify predictive dosimetric parameters. Methods and Materials: We identified patients who received SBRT for central tumors according to either of 2 definitions. Local failure (LF) was estimated using a competing risks model, and multivariate analysis (MVA) was used to assess factors associated with LF. We reviewed patient toxicity and applied Cox proportional hazard analysis and log-rank tests to assess whether dose-volume metrics of normal structures correlated with pulmonary toxicity. Results: One hundred twenty-five patients received SBRT for non-small cell lung cancer (n=103) or metastatic lesions (n=22), using intensity modulated radiation therapy. The most common dose was 45 Gy in 5 fractions. Median follow-up was 17.4 months. Incidence of toxicity ≥ grade 3 was 8.0%, including 5.6% pulmonary toxicity. Sixteen patients (12.8%) experienced esophageal toxicity ≥ grade 2, including 50% of patients in whom PTV overlapped the esophagus. There were 2 treatment-related deaths. Among patients receiving biologically effective dose (BED) ≥80 Gy (n=108), 2-year LF was 21%. On MVA, gross tumor volume (GTV) was significantly associated with LF. None of the studied dose-volume metrics of the lungs, heart, proximal bronchial tree (PBT), or 2 cm expansion of the PBT (“no-fly-zone” [NFZ]) correlated with pulmonary toxicity ≥grade 2. There were no differences in pulmonary toxicity between central tumors located inside the NFZ and those outside the NFZ but with planning target volume (PTV) intersecting the mediastinum. Conclusions: Using moderate doses, SBRT for central lung tumors achieves acceptable local control with low rates of severe toxicity. Dosimetric analysis showed no significant correlation between dose to the lungs, heart, or NFZ and

  1. SU-F-T-391: Comparative Study of Treatment Planning Between IMRT and IMAT for Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Duan, J

    2016-01-01

    Purpose: The purpose of this study was to compare the dosimetric differences between intensitymodulated radiation therapy (IMRT) and intensity modulated arc therapy (IMAT) for malignant pleural mesothelioma (MPM) patients with regard to the sparing effect on organs at risk (OARs), plan quality, and delivery efficiency. Methods: Ten MPM patients were recruited in this study. To avoid the inter-operator variability, IMRT and IMAT plans for each patient were performed by one experienced dosimetrist. The treatment planning optimization process was carried out using the Eclipse 13.0 software. For a fair comparison, the planning target volume (PTV) coverage of the two plans was normalized to the same level. The treatment plans were evaluated on the following dosimetric variables: conformity index (CI) and homogeneity index (HI) for PTV, OARs dose, and the delivery efficiency for each plan. Results: All plans satisfied clinical requirements. The IMAT plans gained better CI and HI. The IMRT plans performed better sparing for heart and lung. Less MUs and control points were found in the IMAT plans. IMAT shortened delivery time compared with IMRT. Conclusion: For MPM, IMAT gains better conformity and homogeneity for PTV with IMRT, but increases the irradiation dose for OARs. IMAT shows an advantage in delivery efficiency.

  2. SU-F-T-391: Comparative Study of Treatment Planning Between IMRT and IMAT for Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Duan, J [Shandong Cancer Hospital and Institute, Jinan, Shandong province (China)

    2016-06-15

    Purpose: The purpose of this study was to compare the dosimetric differences between intensitymodulated radiation therapy (IMRT) and intensity modulated arc therapy (IMAT) for malignant pleural mesothelioma (MPM) patients with regard to the sparing effect on organs at risk (OARs), plan quality, and delivery efficiency. Methods: Ten MPM patients were recruited in this study. To avoid the inter-operator variability, IMRT and IMAT plans for each patient were performed by one experienced dosimetrist. The treatment planning optimization process was carried out using the Eclipse 13.0 software. For a fair comparison, the planning target volume (PTV) coverage of the two plans was normalized to the same level. The treatment plans were evaluated on the following dosimetric variables: conformity index (CI) and homogeneity index (HI) for PTV, OARs dose, and the delivery efficiency for each plan. Results: All plans satisfied clinical requirements. The IMAT plans gained better CI and HI. The IMRT plans performed better sparing for heart and lung. Less MUs and control points were found in the IMAT plans. IMAT shortened delivery time compared with IMRT. Conclusion: For MPM, IMAT gains better conformity and homogeneity for PTV with IMRT, but increases the irradiation dose for OARs. IMAT shows an advantage in delivery efficiency.

  3. Pathologic contrast enhancement of cerebral lesions: A comparative study using stereotactic CT, stereotactic MR imaging, and stereotactic biopsy

    International Nuclear Information System (INIS)

    Earnest, F. IV; Kelly, P.J.; Scheithauer, B.; Kall, B.; Cascino, T.L.; Ehman, R.L.; Forbes, G.

    1986-01-01

    The author compared the pattern and degree of Gd-DTPA dimeglumine contrast enhancement demonstrated on stereotactic MR images with that seen on stereotactic CT images obtained after conventional iodinated contrast agent enhancement and with histopathologic findings on sequential stereotactic brain biopsies. Stereotactic biopsies of the areas that enhanced on CT or MR imaging revealed tumor tissue with neovascularity. Tumor tissue with no or mild neovascularity did not enhance with contrast agent administration. Isolated tumor cells were frequently found beyond the margins of some primary brain neoplasms defined by contrast agent-enhanced MR imaging and CT. The histopathologic findings associated with pathologic contrast agent enhancement are presented

  4. SU-F-T-150: Comparing Normal Tissue Irradiated Volumes for Proton Vs. Photon Treatment Plans On Lung Patients

    Energy Technology Data Exchange (ETDEWEB)

    Liu, A; Mohan, R; Liao, Z [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: The aim of this work is to compare the “irradiated volume” (IRV) of normal tissues receiving 5, 20, 50, 80 and 90% or higher of the prescription dose with passively scattered proton therapy (PSPT) vs. IMRT of lung cancer patients. The overall goal of this research is to understand the factors affecting outcomes of a randomized PSPT vs. IMRT lung trial. Methods: Thirteen lung cancer patients, selected randomly, were analyzed. Each patient had PSPT and IMRT 74 Gy (RBE) plans meeting the same normal tissue constraints generated. IRVs were created for pairs of IMRT and PSPT plans on each patient. The volume of iGTV, (respiratory motion-incorporated GTV) was subtracted from each IRV to create normal tissue irradiated volume IRVNT. The average of IRVNT DVHs over all patients was also calculated for both modalities and inter-compared as were the selected dose-volume indices. Probability (p value) curves were calculated based on the Wilcoxon matched-paired signed-rank test to determine the dose regions where the statistically significant differences existed. Results: As expected, the average 5, 20 and 50% IRVNT’s for PSPT was found to be significantly smaller than for IMRT (p < 0.001, 0.01, and 0.001 respectively). However, the average 90% IRVNT for PSPT was greater than for IMRT (p = 0.003) presumably due to larger penumbra of protons and the long range of protons in lower density media. The 80% IRVNT for PSPT was also larger but not statistically distinguishable (p = .224). Conclusion: PSPT modality has smaller irradiated volume at lower doses, but larger volume at high doses. A larger cohort of lung patients will be analyzed in the future and IRVNT of patients treated with PSPT and IMRT will be compared to determine if the irradiated volumes (the magnitude of “dose bath”) correlate with outcomes.

  5. Impact of field number and beam angle on functional image-guided lung cancer radiotherapy planning

    Science.gov (United States)

    Tahir, Bilal A.; Bragg, Chris M.; Wild, Jim M.; Swinscoe, James A.; Lawless, Sarah E.; Hart, Kerry A.; Hatton, Matthew Q.; Ireland, Rob H.

    2017-09-01

    To investigate the effect of beam angles and field number on functionally-guided intensity modulated radiotherapy (IMRT) normal lung avoidance treatment plans that incorporate hyperpolarised helium-3 magnetic resonance imaging (3He MRI) ventilation data. Eight non-small cell lung cancer patients had pre-treatment 3He MRI that was registered to inspiration breath-hold radiotherapy planning computed tomography. IMRT plans that minimised the volume of total lung receiving  ⩾20 Gy (V20) were compared with plans that minimised 3He MRI defined functional lung receiving  ⩾20 Gy (fV20). Coplanar IMRT plans using 5-field manually optimised beam angles and 9-field equidistant plans were also evaluated. For each pair of plans, the Wilcoxon signed ranks test was used to compare fV20 and the percentage of planning target volume (PTV) receiving 90% of the prescription dose (PTV90). Incorporation of 3He MRI led to median reductions in fV20 of 1.3% (range: 0.2-9.3% p  =  0.04) and 0.2% (range: 0 to 4.1%; p  =  0.012) for 5- and 9-field arrangements, respectively. There was no clinically significant difference in target coverage. Functionally-guided IMRT plans incorporating hyperpolarised 3He MRI information can reduce the dose received by ventilated lung without comprising PTV coverage. The effect was greater for optimised beam angles rather than uniformly spaced fields.

  6. Simple Factors Associated With Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy of the Thorax: A Pooled Analysis of 88 Studies

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jing [Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia (United States); Department of Oncology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan (China); Yorke, Ellen D. [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Li, Ling [Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia (United States); Department of Shanghai Cancer Hospital, Fudan University, Shanghai (China); Kavanagh, Brian D. [Department of Radiation Oncology, University of Colorado, Denver, Colorado (United States); Li, X. Allen [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Das, Shiva [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Miften, Moyed [Department of Radiation Oncology, University of Colorado, Denver, Colorado (United States); Rimner, Andreas [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York City, New York (United States); Campbell, Jeffrey [Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia (United States); Xue, Jinyu [Department of Radiation Oncology, MD Anderson Cancer Center at Cooper, Camden, New Jersey (United States); Jackson, Andrew [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Grimm, Jimm [Bott Cancer Center, Holy Redeemer Hospital, Meadowbrook, Pennsylvania (United States); Milano, Michael T. [Department of Radiation Oncology, University of Rochester, Rochester, New York (United States); and others

    2016-08-01

    Purpose: To study the risk factors for radiation-induced lung toxicity (RILT) after stereotactic body radiation therapy (SBRT) of the thorax. Methods and Materials: Published studies on lung toxicity in patients with early-stage non–small cell lung cancer (NSCLC) or metastatic lung tumors treated with SBRT were pooled and analyzed. The primary endpoint was RILT, including pneumonitis and fibrosis. Data of RILT and risk factors were extracted from each study, and rates of grade 2 to 5 (G2+) and grade 3 to 5 (G3+) RILT were computed. Patient, tumor, and dosimetric factors were analyzed for their correlation with RILT. Results: Eighty-eight studies (7752 patients) that reported RILT incidence were eligible. The pooled rates of G2+ and G3+ RILT from all 88 studies were 9.1% (95% confidence interval [CI]: 7.15-11.4) and 1.8% (95% CI: 1.3-2.5), respectively. The median of median tumor sizes was 2.3 (range, 1.4-4.1) cm. Among the factors analyzed, older patient age (P=.044) and larger tumor size (the greatest diameter) were significantly correlated with higher rates of G2+ (P=.049) and G3+ RILT (P=.001). Patients with stage IA versus stage IB NSCLC had significantly lower risks of G2+ RILT (8.3% vs 17.1%, odds ratio = 0.43, 95% CI: 0.29-0.64, P<.0001). Among studies that provided detailed dosimetric data, the pooled analysis demonstrated a significantly higher mean lung dose (MLD) (P=.027) and V20 (P=.019) in patients with G2+ RILT than in those with grade 0 to 1 RILT. Conclusions: The overall rate of RILT is relatively low after thoracic SBRT. Older age and larger tumor size are significant adverse risk factors for RILT. Lung dosimetry, specifically lung V20 and MLD, also significantly affect RILT risk.

  7. Comparison between intensity modulated radiotherapy (IMRT) and 3D tangential beams technique used in patients with early-stage breast cancer who received breast-conserving therapy

    International Nuclear Information System (INIS)

    Sas-Korczynska, B.; Kokoszka, A.; Korzeniowski, S.; Sladowska, A.; Rozwadowska-Bogusz, B.; Lesiak, J.; Dyczek, S.

    2010-01-01

    Background: The most often found complications in patients with breast cancer who received radiotherapy are cardiac and pulmonary function disorders and development of second malignancies. Aim: To compare the intensity modulated radiotherapy with the 3D tangential beams technique in respect of dose distribution in target volume and critical organs they generate in patients with early-stage breast cancer who received breast-conserving therapy. Materials and methods: A dosimetric analysis was performed to assess the three radiotherapy techniques used in each of 10 consecutive patients with early-stage breast cancer treated with breast-conserving therapy. Radiotherapy was planned with the use of all the three techniques: 3D tangential beams with electron boost, IMRT with electron boost, and intensity modulated radiotherapy with simultaneous integrated boost. Results: The use of the IMRT techniques enables more homogenous dose distribution in target volume. The range of mean and median dose to the heart and lung was lower with the IMRT techniques in comparison to the 3D tangential beams technique. The range of mean dose to the heart amounted to 0.3 - 3.5 Gy for the IMRT techniques and 0.4 - 4.3 for the tangential beams technique. The median dose to the lung on the irradiated side amounted to 4.9 - 5 Gy for the IMRT techniques and 5.6 Gy for the 3D tangential beams technique. Conclusion: The application of the IMRT techniques in radiotherapy patients with early-stage breast cancer allows to obtain more homogenous dose distribution in target volume, while permitting to reduce the dose to critical organs. (authors)

  8. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    Energy Technology Data Exchange (ETDEWEB)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa [Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); Department of Neurosurgery, Division of Radiotherapy, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); CyberKnife Centre, Centro Diagnostico Italiano, 20147 Milano (Italy); Division of Medical Physics, Fondazione IRCCS, Istituto S. Raffaele, 20132 Milano (Italy); Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy)

    2010-07-15

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  9. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    International Nuclear Information System (INIS)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa

    2010-01-01

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  10. The potential role of respiratory motion management and image guidance in the reduction of severe toxicities following stereotactic ablative radiation therapy for patients with centrally located early stage non-small cell lung cancer or lung metastases

    Directory of Open Access Journals (Sweden)

    Alexander eChi

    2014-06-01

    Full Text Available Image guidance allows delivery of very high doses of radiation over a few fractions, known as stereotactic ablative radiotherapy (SABR. This treatment is associated with excellent outcome for early stage non-small cell lung cancer and metastases to the lungs. In the delivery of SABR, central location constantly poses a challenge due to the difficulty of adequately sparing critical thoracic structures that are immediately adjacent to the tumor if an ablative dose of radiation is to be delivered to the tumor target. As of current, various respiratory motion management and image guidance strategies can be used to ensure accurate tumor target localization prior and/ or during daily treatment, which allows for maximal and safe reduction of set up margins. The incorporation of both may lead to the most optimal normal tissue sparing and the most accurate SABR delivery. Here, the clinical outcome, treatment related toxicities, and the pertinent respiratory motion management/image guidance strategies reported in the current literature on SABR for central lung tumors are reviewed.

  11. Comparison of radiotherapy dosimetry for 3D-CRT, IMRT, and SBRT based on electron density calibration

    International Nuclear Information System (INIS)

    Kartutik, K; Pawiro, S A; Wibowo, W E

    2016-01-01

    Accurate calculation of dose distribution affected by inhomogeneity tissue is required in radiotherapy planning. This study was performed to determine the ratio between radiotherapy planning using 3D-CRT, IMRT, and SBRT based on a calibrated curve of CT-number in the lung for different target's shape in 3D-CRT, IMRT, and spinal cord for SBRT. Calibration curves of CT-number were generated under measurement basis and introduced into TPS, then planning was performed for 3D-CRT, IMRT, and SBRT with 7, and 15 radiation fields. Afterwards, planning evaluation was performed by comparing the DVH curve, HI, and CI. 3D-CRT and IMRT produced the lowest HI at calibration curve of CIRS 002LFC with the value 0.24 and 10. Whereas SBRT produced the lowest HI on a linear calibration curve with a value of 0.361. The highest CI in IMRT and SBRT technique achieved using a linear calibration curve was 0.97 and 1.77 respectively. For 3D-CRT, the highest CI was obtained by using calibration curve of CIRS 062M with the value of 0.45. From the results of CI and HI, it is concluded that the calibration curve of CT-number does not significantly differ with Schneider's calibrated curve, and inverse planning gives a better result than forward planning. (paper)

  12. Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Rachit; Wild, Aaron T.; Ziegler, Mark A.; Hooker, Ted K.; Dah, Samson D.; Tran, Phuoc T.; Kang, Jun; Smith, Koren; Zeng, Jing [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Pawlik, Timothy M. [Department of Surgery, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Tryggestad, Erik [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Ford, Eric [Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Seattle, WA (United States); Herman, Joseph M., E-mail: jherma15@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States)

    2013-10-01

    Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal D{sub max} of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacing between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal D{sub mean}, D{sub max}, D{sub 1cc}, D{sub 4%}, and V{sub 20} {sub Gy} compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V{sub 95%} (p = 0.01) and D{sub mean} (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at

  13. Clinical implications of the anisotropic analytical algorithm for IMRT treatment planning and verification

    International Nuclear Information System (INIS)

    Bragg, Christopher M.; Wingate, Katrina; Conway, John

    2008-01-01

    Purpose: To determine the implications of the use of the Anisotropic Analytical Algorithm (AAA) for the production and dosimetric verification of IMRT plans for treatments of the prostate, parotid, nasopharynx and lung. Methods: 72 IMRT treatment plans produced using the Pencil Beam Convolution (PBC) algorithm were recalculated using the AAA and the dose distributions compared. Twenty-four of the plans were delivered to inhomogeneous phantoms and verification measurements made using a pinpoint ionisation chamber. The agreement between the AAA and measurement was determined. Results: Small differences were seen in the prostate plans, with the AAA predicting slightly lower minimum PTV doses. In the parotid plans, there were small increases in the lens and contralateral parotid doses while the nasopharyngeal plans revealed a reduction in the volume of the PTV covered by the 95% isodose (the V 95% ) when the AAA was used. Large changes were seen in the lung plans, the AAA predicting reductions in the minimum PTV dose and large reductions in the V 95% . The AAA also predicted small increases in the mean dose to the normal lung and the V 20 . In the verification measurements, all AAA calculations were within 3% or 3.5 mm distance to agreement of the measured doses. Conclusions: The AAA should be used in preference to the PBC algorithm for treatments involving low density tissue but this may necessitate re-evaluation of plan acceptability criteria. Improvements to the Multi-Resolution Dose Calculation algorithm used in the inverse planning are required to reduce the convergence error in the presence of lung tissue. There was excellent agreement between the AAA and verification measurements for all sites

  14. CT-guided stereotactic neurosurgery

    International Nuclear Information System (INIS)

    Takizawa, Takaaki; Sato, Shoju; Matsumoto, Akira; Sano, Akira; Takahashi, Kazunori; Murakami, Yuji; Ohta, Kosuke

    1985-01-01

    Brown-Roberts-Wells stereotactic instruments were used for CT guided stereotactic surgery in 54 cases (65 operations). Stereotactic biopsy was done in 9 cases and successive regional chemotherapy was done in 3 cases. Stereotactic drainage was done in 2 cases of bacterial abcess, 3 cases of cystic neoplasm and 33 cases (43 operations) of intracerebral hematoma. CT guided stereotactic procedure was valuable for the correct cannulation to the center of the cavity. We tried to utilize CT image for the selection of targets for stereotactic functional neurosurgical procedures in 6 cases. In the cases of thalamotomy, the information derived from CT made the operation safer than that by contrast ventriculography alone. In all cases of electrode implantation for deep brain stimulation, accurate and precise electrode placement was achieved from CT images alone. This rapid and easy surgical technique was useful also for poor risk patients. (author)

  15. SU-E-J-70: Feasibility Study of Dynamic Arc and IMRT Treatment Plans Utilizing Vero Treatment Unit and IPlan Planning Computer for SRS/FSRT Brain Cancer Patients

    International Nuclear Information System (INIS)

    Huh, S; Lee, S; Dagan, R; Malyapa, R; Mendenhall, N; Mendenhall, W; Ho, M; Hough, D; Yam, M; Li, Z

    2014-01-01

    Purpose: To investigate the feasibility of utilizing Dynamic Arc (DA) and IMRT with 5mm MLC leaf of VERO treatment unit for SRS/FSRT brain cancer patients with non-invasive stereotactic treatments. The DA and IMRT plans using the VERO unit (BrainLab Inc, USA) are compared with cone-based planning and proton plans to evaluate their dosimetric advantages. Methods: The Vero treatment has unique features like no rotational or translational movements of the table during treatments, Dynamic Arc/IMRT, tracking of IR markers, limitation of Ring rotation. Accuracies of the image fusions using CBCT, orthogonal x-rays, and CT are evaluated less than ∼ 0.7mm with a custom-made target phantom with 18 hidden targets. 1mm margin is given to GTV to determine PTV for planning constraints considering all the uncertainties of planning computer and mechanical uncertainties of the treatment unit. Also, double-scattering proton plans with 6F to 9F beams and typical clinical parameters, multiple isocenter plans with 6 to 21 isocenters, and DA/IMRT plans are evaluated to investigate the dosimetric advantages of the DA/IMRT for complex shape of targets. Results: 3 Groups of the patients are divided: (1) Group A (complex target shape), CI's are same for IMRT, and DGI of the proton plan are better by 9.5% than that of the IMRT, (2) Group B, CI of the DA plans (1.91+/−0.4) are better than cone-based plan, while DGI of the DA plan is 4.60+/−1.1 is better than cone-based plan (5.32+/−1.4), (3) Group C (small spherical targets), CI of the DA and cone-based plans are almost the same. Conclusion: For small spherical targets, cone-based plans are superior to other 2 plans: DS proton and DA plans. For complex or irregular plans, dynamic and IMRT plans are comparable to cone-based and proton plans for complex targets

  16. SU-E-T-131: Dosimetric Impact and Evaluation of Different Heterogenity Algorithm in Volumetric Modulated Arc Therapy Plan for Stereotactic Ablative Radiotherapy Lung Treatment with the Flattening Filter Free Beam

    Energy Technology Data Exchange (ETDEWEB)

    Chung, J; Kim, J [Seoul National University Bundang Hospital, Seongnam, Kyeonggi-do (Korea, Republic of); Lee, J [Konkuk University Medical Center, Seoul, Seoul (Korea, Republic of); Kim, Y [Choonhae College of Health Sciences, Ulsan (Korea, Republic of)

    2014-06-01

    Purpose: The present study aimed to investigate the dosimetric impacts of the anisotropic analytic algorithm (AAA) and the Acuros XB (AXB) plan for lung stereotactic ablative radiation therapy using flattening filter-free (FFF) beam. We retrospectively analyzed 10 patients. Methods: We retrospectively analyzed 10 patients. The dosimetric parameters for the target and organs at risk (OARs) from the treatment plans calculated with these dose calculation algorithms were compared. The technical parameters, such as the computation times and the total monitor units (MUs), were also evaluated. Results: A comparison of DVHs from AXB and AAA showed that the AXB plan produced a high maximum PTV dose by average 4.40% with a statistical significance but slightly lower mean PTV dose by average 5.20% compared to the AAA plans. The maximum dose to the lung was slightly higher in the AXB compared to the AAA. For both algorithms, the values of V5, V10 and V20 for ipsilateral lung were higher in the AXB plan more than those of AAA. However, these parameters for contralateral lung were comparable. The differences of maximum dose for the spinal cord and heart were also small. The computation time of AXB was found fast with the relative difference of 13.7% than those of AAA. The average of monitor units (MUs) for all patients was higher in AXB plans than in the AAA plans. These results indicated that the difference between AXB and AAA are large in heterogeneous region with low density. Conclusion: The AXB provided the advantages such as the accuracy of calculations and the reduction of the computation time in lung stereotactic ablative radiotherapy (SABR) with using FFF beam, especially for VMAT planning. In dose calculation with the media of different density, therefore, the careful attention should be taken regarding the impacts of different heterogeneity correction algorithms. The authors report no conflicts of interest.

  17. SU-E-T-131: Dosimetric Impact and Evaluation of Different Heterogenity Algorithm in Volumetric Modulated Arc Therapy Plan for Stereotactic Ablative Radiotherapy Lung Treatment with the Flattening Filter Free Beam

    International Nuclear Information System (INIS)

    Chung, J; Kim, J; Lee, J; Kim, Y

    2014-01-01

    Purpose: The present study aimed to investigate the dosimetric impacts of the anisotropic analytic algorithm (AAA) and the Acuros XB (AXB) plan for lung stereotactic ablative radiation therapy using flattening filter-free (FFF) beam. We retrospectively analyzed 10 patients. Methods: We retrospectively analyzed 10 patients. The dosimetric parameters for the target and organs at risk (OARs) from the treatment plans calculated with these dose calculation algorithms were compared. The technical parameters, such as the computation times and the total monitor units (MUs), were also evaluated. Results: A comparison of DVHs from AXB and AAA showed that the AXB plan produced a high maximum PTV dose by average 4.40% with a statistical significance but slightly lower mean PTV dose by average 5.20% compared to the AAA plans. The maximum dose to the lung was slightly higher in the AXB compared to the AAA. For both algorithms, the values of V5, V10 and V20 for ipsilateral lung were higher in the AXB plan more than those of AAA. However, these parameters for contralateral lung were comparable. The differences of maximum dose for the spinal cord and heart were also small. The computation time of AXB was found fast with the relative difference of 13.7% than those of AAA. The average of monitor units (MUs) for all patients was higher in AXB plans than in the AAA plans. These results indicated that the difference between AXB and AAA are large in heterogeneous region with low density. Conclusion: The AXB provided the advantages such as the accuracy of calculations and the reduction of the computation time in lung stereotactic ablative radiotherapy (SABR) with using FFF beam, especially for VMAT planning. In dose calculation with the media of different density, therefore, the careful attention should be taken regarding the impacts of different heterogeneity correction algorithms. The authors report no conflicts of interest

  18. Comparative cost-effectiveness of stereotactic body radiation therapy versus intensity-modulated and proton radiation therapy for localized prostate cancer.

    Directory of Open Access Journals (Sweden)

    Anju eParthan

    2012-08-01

    Full Text Available Objective. To determine the cost-effectiveness of several external beam radiation treatment modalities for the treatment of patients with localized prostate cancer.Methods. A lifetime Markov model incorporated the probabilities of experiencing treatment-related long-term toxicity or death. Toxicity probabilities were derived from published sources using meta-analytical techniques. Utilities and costs in the model were obtained from publically available secondary sources. The model calculated quality-adjusted life expectancy and expected lifetime cost per patient, and derived ratios of incremental cost per quality-adjusted life year (QALY gained between treatments. Analyses were conducted from both a payer and societal perspectives. One-way and probabilistic sensitivity analyses were performed.Results. Compared to intensity modulated radiation therapy (IMRT and proton beam therapy (PT, stereotactic body radiation therapy (SBRT was less costly and resulted in more QALYs. Sensitivity analyses showed that the conclusions in the base-case scenario were robust with respect to variations in toxicity and cost parameters consistent with available evidence. At a threshold of $50,000/QALY, SBRT was cost effective in 75%, and 94% of probabilistic simulations compared to IMRT and PT, respectively, from a payer perspective. From a societal perspective, SBRT was cost-effective in 75%, and 96% of simulations compared to IMRT and PT, respectively, at a threshold of $50,000/QALY. In threshold analyses, SBRT was less expensive with better outcomes compared to IMRT at toxicity rates 23% greater than the SBRT base-case rates. Conclusions. Based on the assumption that each treatment modality results in equivalent long-term efficacy, SBRT is a cost-effective strategy resulting in improved quality-adjusted survival compared to IMRT and PT for the treatment of localized prostate cancer.

  19. Difficulties encountered and solutions found when implementing stereotactic radiotherapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Assouline, A.; Halley, A.; Belghith, B.; Mazeron, J.J.; Feuvret, L.

    2012-01-01

    The aim of this paper is to describe the difficulties encountered when implementing stereotactic radiotherapy of non-small cell lung cancer (T1-T2, N0, M0) using a voluntary breath-hold technique. From 25/03/2010 to 22/02/2011, eight patients with a non-small cell lung cancer were selected for treatment. CT images were obtained with the patient maintaining breath-hold using a spirometer. Treatment was delivered when the patient maintains this level of breath-hold. Treatment was performed with a 4 MV and 10 MV photon beams from a linear accelerator Varian 2100CS, equipped with a 120 leaves collimator. 60 Gy or 48 Gy were delivered, in four sessions, to the 80% isodose. The planning target volume (PTV) was defined by adding a 5 mm margin to the internal target volume (ITV), the ITV corresponding to the gross tumour volume (GTV) plus a 3 mm margin. CTV is considered equal to GTV. The non-understanding of the gating technique, the great number of beams and the limited breath-hold times led to the failure of some treatments. It can be explained by some patients insufficient respiratory abilities and the low dose rate of one of the beams used for treatment, thus forcing some radiation fields to be delivered in two or three times. Implementing such a technique can be limited by the patients' physical abilities and the materials used. Some solutions were found: a training phase more intense with a coaching of the breath-hold technique more precise, or the use of an abdominal compression device. (authors)

  20. SUNSET: Stereotactic Radiation for Ultracentral Non-Small-Cell Lung Cancer-A Safety and Efficacy Trial.

    Science.gov (United States)

    Giuliani, Meredith; Mathew, Ashwathy S; Bahig, Houda; Bratman, Scott V; Filion, Edith; Glick, Daniel; Louie, Alexander V; Raman, Srinivas; Swaminath, Anand; Warner, Andrew; Yau, Vivian; Palma, David

    2018-04-18

    Lung stereotactic body radiotherapy (SBRT) is considered a standard curative treatment for medically inoperable early stage non-small-cell lung cancer (NSCLC). Patients with ultracentral tumors (signifying tumors whose planning target volume touches or overlaps the central bronchial tree, esophagus, or pulmonary artery) may be at higher risk of serious toxicities such as bronchial stricture and collapse, esophageal strictures, tracheal-esophageal fistula, and hemorrhage. The primary objective of the study is to determine the maximum tolerated dose of radiotherapy for ultracentral NSCLC. This multicenter phase 1 dose-escalation study will use a time-to-event continual reassessment method (TITE-CRM). Accrual will start at level 1 (60 Gy in 8 fractions delivered daily). The model will use all available information from previously accrued patients to assign the highest dose with a predicted risk of grade 3-5 toxicity of 30% or less. All patients with newly diagnosed stage T1-3 N0M0 NSCLC (International Union Against Cancer, 8th edition) with tumor size ≤ 6 cm and meeting the criteria for ultracentral location (ie, tumors whose planning target volume touches or overlaps the central bronchial tree, esophagus, pulmonary vein, or pulmonary artery) will be eligible for this study. It is important to identify a safe dose-fractionation regimen for treating ultracentral tumors with SBRT. In addition, the data from this study may be informative in guiding future studies on the use of SBRT in treating malignancies within the mediastinum-for example, for salvage treatment of mediastinal lymph nodes for recurrent NSCLC or mediastinal oligometastases. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. TH-E-BRE-08: GPU-Monte Carlo Based Fast IMRT Plan Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Li, Y; Tian, Z; Shi, F; Jiang, S; Jia, X [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States)

    2014-06-15

    Purpose: Intensity-modulated radiation treatment (IMRT) plan optimization needs pre-calculated beamlet dose distribution. Pencil-beam or superposition/convolution type algorithms are typically used because of high computation speed. However, inaccurate beamlet dose distributions, particularly in cases with high levels of inhomogeneity, may mislead optimization, hindering the resulting plan quality. It is desire to use Monte Carlo (MC) methods for beamlet dose calculations. Yet, the long computational time from repeated dose calculations for a number of beamlets prevents this application. It is our objective to integrate a GPU-based MC dose engine in lung IMRT optimization using a novel two-steps workflow. Methods: A GPU-based MC code gDPM is used. Each particle is tagged with an index of a beamlet where the source particle is from. Deposit dose are stored separately for beamlets based on the index. Due to limited GPU memory size, a pyramid space is allocated for each beamlet, and dose outside the space is neglected. A two-steps optimization workflow is proposed for fast MC-based optimization. At first step, rough beamlet dose calculations is conducted with only a small number of particles per beamlet. Plan optimization is followed to get an approximated fluence map. In the second step, more accurate beamlet doses are calculated, where sampled number of particles for a beamlet is proportional to the intensity determined previously. A second-round optimization is conducted, yielding the final Result. Results: For a lung case with 5317 beamlets, 10{sup 5} particles per beamlet in the first round, and 10{sup 8} particles per beam in the second round are enough to get a good plan quality. The total simulation time is 96.4 sec. Conclusion: A fast GPU-based MC dose calculation method along with a novel two-step optimization workflow are developed. The high efficiency allows the use of MC for IMRT optimizations.

  2. Stereotactic treatment. Definitions and literature overview

    International Nuclear Information System (INIS)

    Fontenla, D.P.

    2008-01-01

    The topics discussed include, among others, the following: Radiosurgery definitions; Stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT); Available uncertainties in SRS; Gamma knife; Linac-based SRS; Components of a radiosurgery system; Stereotactic hardware (brain lab); m3 linac attachment; Radiosurgery - clinical procedure; Cancer management; Rationale for SRT; Role of radiosurgery in the management of intracranial tumors; Indications for stereotactic SRS/SRT; Physical components required for SRS/SRT; Stereotactic patient set-up; Stereotactic CT scan for SRS; Physical components required for SRT: Relocatable head frame (GTC); Patient immobilization; Treatment planning system; Basic requirements for SRS dosimetry (Linac based); Stereotactic set-up QA (Linac); Stereotactic frames and QA; Beam dose measurements; Dose evaluation tools; Phantoms. (P.A.)

  3. Extracranial stereotactic radiotherapy: preliminary results with the CyberKnife.

    Science.gov (United States)

    Lartigau, Eric; Mirabel, Xavier; Prevost, Bernard; Lacornerie, Thomas; Dubus, Francois; Sarrazin, Thierry

    2009-04-01

    In the field of radiation oncology, equipment for fractionated radiotherapy and single-dose radiosurgery has become increasingly accurate, together with the introduction of robotized treatments. A robot is a device that can be programmed to carry out accurate, repeated and adjusted tasks in a given environment. Treatment of extracranial lesions involves taking into account organ mobility (tumor and healthy tissue) whilst retaining the ability to stereotactically locate the target. New imaging techniques (single-photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), positron emission tomography (PET)) provide further relevant information to slice images (computed tomography (CT) scans, MRI) for target definition. Hypo-fractionated treatments can only be used for curative treatment if the target is accurately defined and tracked during treatment. The CyberKnife is a non-invasive system of radiosurgery and fractionated stereotactic radiotherapy. For intracranial lesions treated by single-dose radiosurgery, it has been used to treat meningioma, acoustic neuromas, pituitary adenoma, metastases, arteriovenous malformations and refractory pain (trigeminal neuralgia). More than 10,000 patients have been treated worldwide. Currently, the most significant developments are in the field of extracranial stereotactic radiotherapy (lung, liver, reirradiation, prostate, etc.). Clinical results obtained in the CyberKnife Nord-Ouest program after 1 year of experience are presented. Copyright 2009 S. Karger AG, Basel.

  4. Toxicity After Central versus Peripheral Lung Stereotactic Body Radiation Therapy: A Propensity Score Matched-Pair Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mangona, Victor S. [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Aneese, Andrew M. [Oakland University William Beaumont School of Medicine, Rochester, Michigan (United States); Marina, Ovidiu; Hymas, Richard V. [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Ionascu, Dan; Robertson, John M. [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Oakland University William Beaumont School of Medicine, Rochester, Michigan (United States); Gallardo, Lori J. [Oakland University William Beaumont School of Medicine, Rochester, Michigan (United States); Department of Radiology, Beaumont Health System, Royal Oak, Michigan (United States); Grills, Inga Siiner, E-mail: igrills@beaumont.edu [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Oakland University William Beaumont School of Medicine, Rochester, Michigan (United States)

    2015-01-01

    Purpose: To compare toxicity after stereotactic body radiation therapy (SBRT) for “central” tumors—within 2 cm of the proximal bronchial tree or with planning tumor volume (PTV) touching mediastinum—versus noncentral (“peripheral”) lung tumors. Methods and Materials: From November 2005 to January 2011, 229 tumors (110 central, 119 peripheral; T1-3N0M0 non–small-cell lung cancer and limited lung metastases) in 196 consecutive patients followed prospectively at a single institution received moderate-dose SBRT (48-60 Gy in 4-5 fractions [biologic effective dose=100-132 Gy, α/β=10]) using 4-dimensional planning, online image-guided radiation therapy, and institutional dose constraints. Clinical adverse events (AEs) were graded prospectively at clinical and radiographic follow-up using Common Terminology Criteria for Adverse Events version 3.0. Pulmonary function test (PFT) decline was graded as 2 (25%-49.9% decline), 3 (50.0%-74.9% decline), or 4 (≥75.0% decline). Central/peripheral location was assessed retrospectively on planning CT scans. Groups were compared after propensity score matching. Characteristics were compared with χ{sup 2} and 2-tailed t tests, adverse events with χ{sup 2} test-for-trend, and cumulative incidence using competing risks analysis (Gray's test). Results: With 79 central and 79 peripheral tumors matched, no differences in AEs were observed after 17 months median follow-up. Two-year cumulative incidences of grade ≥2 pain, musculoskeletal, pulmonary, and skin AEs were 14%, 5%, 6%, and 10% (central) versus 19%, 10%, 10%, and 3% (peripheral), respectively (P=.31, .38, .70, and .09). Grade ≥2 cardiovascular, gastrointestinal, and central nervous system AEs were rare (<1%). Two-year incidences of grade ≥2 clinical AEs (28% vs 25%, P=.79), grade ≥2 PFT decline (36% vs 34%, P=.94), grade ≥3 clinical AEs (3% vs 7%, P=.48), and grade ≥3 PFT decline (0 vs 10%, P=.11) were similar for central versus peripheral

  5. Available evidence on re-irradiation with stereotactic ablative radiotherapy following high-dose previous thoracic radiotherapy for lung malignancies.

    Science.gov (United States)

    De Bari, Berardino; Filippi, Andrea Riccardo; Mazzola, Rosario; Bonomo, Pierluigi; Trovò, Marco; Livi, Lorenzo; Alongi, Filippo

    2015-06-01

    Patients affected with intra-thoracic recurrences of primary or secondary lung malignancies after a first course of definitive radiotherapy have limited therapeutic options, and they are often treated with a palliative intent. Re-irradiation with stereotactic ablative radiotherapy (SABR) represents an appealing approach, due to the optimized dose distribution that allows for high-dose delivery with better sparing of organs at risk. This strategy has the goal of long-term control and even cure. Aim of this review is to report and discuss published data on re-irradiation with SABR in terms of efficacy and toxicity. Results indicate that thoracic re-irradiation may offer satisfactory disease control, however the data on outcome and toxicity are derived from low quality retrospective studies, and results should be cautiously interpreted. As SABR may be associated with serious toxicity, attention should be paid for an accurate patients' selection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: Marker placement and early results

    International Nuclear Information System (INIS)

    Nuyttens, J.J.; Prevost, J.B.; Praag, J.; Hoogeman, M.; Levendag, P.C.; Klaveren, R.J. van; Pattynama, P.M.T.

    2006-01-01

    Lung tumor tracking during stereotactic radiotherapy with the CyberKnife requires the insertion of markers in or close to the tumor. To reduce the risk of pneumothorax, three methods of marker placement were used: 1) intravascular coil placement, 2) percutaneous intrathoracal, and 3) percutaneous extrathoracal placement. We investigated the toxicity of marker placement and the tumor response of the lung tumor tracking treatment. Markers were placed in 20 patients with 22 tumors: 13 patients received a curative treatment, seven a palliative. The median Charlson Comorbidity Score was 4 (range: 1-8). Platinum fiducials and intravascular embolisation coils were used as markers. In total, 78 markers were placed: 34 intrathoracal, 23 intravascular and 21 extrathoracal. The PTV equaled the GTV + 5 mm. A median dose of 45 Gy (range: 30-60 Gy, in 3 fractions) was prescribed to the 70-85% isodose. The response was evaluated with a CTscan performed 6-8 weeks after the last treatment and routinely thereafter. The median follow-up was 4 months (range: 2-11). No severe toxicity due to the marker placement was seen. Pneumothorax was not seen. The local control was 100%. Four tumors in four patients showed a complete response, 15 tumors in 14 patients a partial response, and three tumors in two patients with metastatic disease had stable disease. No severe toxicity of marker placement was seen due to the appropriate choice of one of the three methods. CyberKnife tumor tracking with markers is feasible and resulted in excellent tumor response. Longer follow-up is needed to validate the local control

  7. Texture analysis of automatic graph cuts segmentations for detection of lung cancer recurrence after stereotactic radiotherapy

    Science.gov (United States)

    Mattonen, Sarah A.; Palma, David A.; Haasbeek, Cornelis J. A.; Senan, Suresh; Ward, Aaron D.

    2015-03-01

    Stereotactic ablative radiotherapy (SABR) is a treatment for early-stage lung cancer with local control rates comparable to surgery. After SABR, benign radiation induced lung injury (RILI) results in tumour-mimicking changes on computed tomography (CT) imaging. Distinguishing recurrence from RILI is a critical clinical decision determining the need for potentially life-saving salvage therapies whose high risks in this population dictate their use only for true recurrences. Current approaches do not reliably detect recurrence within a year post-SABR. We measured the detection accuracy of texture features within automatically determined regions of interest, with the only operator input being the single line segment measuring tumour diameter, normally taken during the clinical workflow. Our leave-one-out cross validation on images taken 2-5 months post-SABR showed robustness of the entropy measure, with classification error of 26% and area under the receiver operating characteristic curve (AUC) of 0.77 using automatic segmentation; the results using manual segmentation were 24% and 0.75, respectively. AUCs for this feature increased to 0.82 and 0.93 at 8-14 months and 14-20 months post SABR, respectively, suggesting even better performance nearer to the date of clinical diagnosis of recurrence; thus this system could also be used to support and reinforce the physician's decision at that time. Based on our ongoing validation of this automatic approach on a larger sample, we aim to develop a computer-aided diagnosis system which will support the physician's decision to apply timely salvage therapies and prevent patients with RILI from undergoing invasive and risky procedures.

  8. Emerging Therapies for Stage III Non-Small Cell Lung Cancer: Stereotactic Body Radiation Therapy and Immunotherapy

    Directory of Open Access Journals (Sweden)

    Sameera S. Kumar

    2017-09-01

    Full Text Available The current standard of care for locally advanced non-small cell lung cancer (NSCLC includes radiation, chemotherapy, and surgery in certain individualized cases. In unresectable NSCLC, chemoradiation has been the standard of care for the past three decades. Local and distant failure remains high in this group of patients, so dose escalation has been studied in both single institution and national clinical trials. Though initial studies showed a benefit to dose escalation, phase III studies examining dose escalation using standard fractionation or hyperfractionation have failed to show a benefit. Over the last 17 years, stereotactic body radiation therapy (SBRT has shown a high degree of safety and local control for stage I lung cancers and other localized malignancies. More recently, phase I/II studies using SBRT for dose escalation after conventional chemoradiation in locally advanced NSCLC have been promising with good apparent safety. Immunotherapy also offers opportunities to address distant disease and preclinical data suggest immunotherapy in tandem with SBRT may be a rational way to induce an “abscopal effect” although there are little clinical data as yet. By building on the proven concept of conventional chemoradiation for patients with locally advanced NSCLC with a subsequent radiation dose intensification to residual disease with SBRT concurrent with immunotherapy, we hope address the issues of metastatic and local failures. This “quadmodality” approach is still in its infancy but appears to be a safe and rational approach to the improving the outcome of NSCLC therapy.

  9. High-resolution pulmonary ventilation and perfusion PET/CT allows for functionally adapted intensity modulated radiotherapy in lung cancer

    International Nuclear Information System (INIS)

    Siva, Shankar; Thomas, Roshini; Callahan, Jason; Hardcastle, Nicholas; Pham, Daniel; Kron, Tomas; Hicks, Rodney J.; MacManus, Michael P.; Ball, David L.; Hofman, Michael S.

    2015-01-01

    Background and purpose: To assess the utility of functional lung avoidance using IMRT informed by four-dimensional (4D) ventilation/perfusion (V/Q) PET/CT. Materials and methods: In a prospective clinical trial, patients with non-small cell lung cancer (NSCLC) underwent 4D-V/Q PET/CT scanning before 60 Gy of definitive chemoradiation. Both “highly perfused” (HPLung) and “highly ventilated” (HVLung) lung volumes were delineated using a 70th centile SUV threshold, and a “ventilated lung volume” (VLung) was created using a 50th centile SUV threshold. For each patient four IMRT plans were created, optimised to the anatomical lung, HPLung, HVLung and VLung volumes, respectively. Improvements in functional dose volumetrics when optimising to functional volumes were assessed using mean lung dose (MLD), V5, V10, V20, V30, V40, V50 and V60 parameters. Results: The study cohort consisted of 20 patients with 80 IMRT plans. Plans optimised to HPLung resulted in a significant reduction of functional MLD by a mean of 13.0% (1.7 Gy), p = 0.02. Functional V5, V10 and V20 were improved by 13.2%, 7.3% and 3.8% respectively (p-values < 0.04). There was no significant sparing of dose to functional lung when adapting to VLung or HVLung. Plan quality was highly consistent with a mean PTV D95 and D5 ranging from 60.8 Gy to 61.0 Gy and 63.4 Gy to 64.5 Gy, respectively, and mean conformity and heterogeneity index ranging from 1.11 to 1.17 and 0.94 to 0.95, respectively. Conclusion: IMRT plans adapted to perfused but not ventilated lung on 4D-V/Q PET/CT allowed for reduced dose to functional lung whilst maintaining consistent plan quality

  10. Salvage Stereotactic Body Radiation Therapy (SBRT) for Local Failure After Primary Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Hearn, Jason W.D., E-mail: hearnj@ccf.org; Videtic, Gregory M.M.; Djemil, Toufik; Stephans, Kevin L.

    2014-10-01

    Purpose: Local failure after definitive stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (NSCLC) is uncommon. We report the safety and efficacy of SBRT for salvage of local failure after previous SBRT with a biologically effective dose (BED) of ≥100 Gy{sub 10}. Methods and Materials: Using an institutional review board–approved lung SBRT registry, we identified all patients initially treated for early-stage NSCLC between August 2004 and January 2012 who received salvage SBRT for isolated local failure. Failure was defined radiographically and confirmed histologically unless contraindicated. All patients were treated on a Novalis/BrainLAB system using ExacTrac for image guidance, and received a BED of ≥100 Gy{sub 10} for each SBRT course. Tumor motion control involved a Bodyfix vacuum system for immobilization along with abdominal compression. Results: Of 436 patients treated from August 2004 through January 2012, we identified 22 patients with isolated local failure, 10 of whom received SBRT for salvage. The median length of follow-up was 13.8 months from salvage SBRT (range 5.3-43.5 months). Median tumor size was 3.4 cm (range 1.7-4.8 cm). Two of the 10 lesions were “central” by proximity to the mediastinum, but were outside the zone of the proximal bronchial tree. Since completing salvage, 3 patients are alive and without evidence of disease. A fourth patient died of medical comorbidities without recurrence 13.0 months after salvage SBRT. Two patients developed distant disease only. Four patients had local failure. Toxicity included grade 1-2 fatigue (3 patients) and grade 1-2 chest wall pain (5 patients). There was no grade 3-5 toxicity. Conclusions: Repeat SBRT with a BED of ≥100 Gy{sub 10} after local failure in patients with early-stage medically inoperable NSCLC was well tolerated in this series and may represent a viable salvage strategy in select patients with peripheral tumors ≤5 cm.

  11. CT appearance of radiation injury of the lung and clinical symptoms after stereotactic body radiation therapy (SBRT) for lung cancers: Are patients with pulmonary emphysema also candidates for SBRT for lung cancers?

    International Nuclear Information System (INIS)

    Kimura, Tomoki; Matsuura, Kanji; Murakami, Yuji; Hashimoto, Yasutoshi; Kenjo, Masahiro; Kaneyasu, Yuko; Wadasaki, Koichi; Hirokawa, Yutaka; Ito, Katsuhide; Okawa, Motoomi

    2006-01-01

    Purpose: The purpose of this study was to analyze the computed tomographic (CT) appearance of radiation injury to the lung and clinical symptoms after stereotactic body radiation therapy (SBRT) and evaluate the difference by the presence of pulmonary emphysema (PE) for small lung cancers. Methods and Materials: In this analysis, 45 patients with 52 primary or metastatic lung cancers were enrolled. We evaluated the CT appearance of acute radiation pneumonitis (within 6 months) and radiation fibrosis (after 6 months) after SBRT. Clinical symptoms were evaluated by Common Terminology Criteria for Adverse Events, version 3.0. We also evaluated the relationship between CT appearance, clinical symptoms, and PE. Results: CT appearance of acute radiation pneumonitis was classified as follows: (1) diffuse consolidation, 38.5%; (2) patchy consolidation and ground-glass opacities (GGO), 15.4%; (3) diffuse GGO, 11.5%; (4) patchy GGO, 2.0%; (5) no evidence of increasing density, 32.6%. CT appearance of radiation fibrosis was classified as follows: (1) modified conventional pattern, 61.5%; (2) mass-like pattern, 17.3%; (3) scar-like pattern, 21.2%. Patients who were diagnosed with more than Grade 2 pneumonitis showed significantly less no evidence of increased density pattern and scar-like pattern than any other pattern (p = 0.0314, 0.0297, respectively). Significantly, most of these patients with no evidence of increased density pattern and scar-like pattern had PE (p = 0.00038, 0.00044, respectively). Conclusion: Computed tomographic appearance after SBRT was classified into five patterns of acute radiation pneumonitis and three patterns of radiation fibrosis. Our results suggest that SBRT can be also safely performed even in patients with PE

  12. Treatment planning study comparing proton therapy, RapidArc and intensity modulated radiation therapy for a synchronous bilateral lung cancer case

    Directory of Open Access Journals (Sweden)

    Suresh Rana

    2014-03-01

    Full Text Available Purpose: The main purpose of this study is to perform a treatment planning study on a synchronous bilateral non-small cell lung cancer case using three treatment modalities: uniform scanning proton therapy, RapidArc, and intensity modulated radiation therapy (IMRT. Methods: The maximum intensity projection (MIP images obtained from the 4 dimensional-computed tomography (4DCT scans were used for delineation of tumor volumes in the left and right lungs. The average 4D-CT was used for the treatment planning among all three modalities with identical patient contouring and treatment planning goal. A proton therapy plan was generated in XiO treatment planning system (TPS using 2 fields for each target. For a comparative purpose, IMRT and RapidArc plans were generated in Eclipse TPS. Treatment plans were generated for a total dose of 74 CGE or Gy prescribed to each planning target volume (PTV (left and right with 2 CGE or Gy per fraction. In IMRT and RapidArc plans, normalization was done based on PTV coverage values in proton plans. Results: The mean PTV dose deviation from the prescription dose was lower in proton plan (within 3.4%, but higher in IMRT (6.5% to 11.3% and RapidArc (3.8% to 11.5% plans. Proton therapy produced lower mean dose to the total lung, heart, and esophagus when compared to IMRT and RapidArc. The relative volume of the total lung receiving 20, 10, and 5 CGE or Gy (V20, V10, and V5, respectively were lower using proton therapy than using IMRT, with absolute differences of 9.71%, 22.88%, and 39.04%, respectively. The absolute differences in the V20, V10, and V5 between proton and RapidArc plans were 4.84%, 19.16%, and 36.8%, respectively, with proton therapy producing lower dosimetric values. Conclusion: Based on the results presented in this case study, uniform scanning proton therapy has a dosimetric advantage over both IMRT and RapidArc for a synchronous bi-lateral NSCLC, especially for the normal lung tissue, heart, and

  13. Comprehensive clinical study of concurrent chemotherapy breathing IMRT middle part of locally advanced esophageal cancer

    International Nuclear Information System (INIS)

    Jung, Jae Hong; Moon, Seong Kwon; Kim, Seung Chul

    2015-01-01

    The standard treatment of locally advanced type of mid-esophageal cancer is concurrent chemoradiation therapy (CRT). We evaluated the feasibility of chemotherapy with adding docetaxel to the classical basic regimens of cisplatin plus 5-fluorouracil (5-FU) and radiotherapy up to 70.2 Gy using dose escalations for esophageal cancer. It was possible to escalate radiation treatment dose up to 70.2 Gy by the respiratory-gated intensity- modulated radiotherapy (gated-IMRT) based on the 4DCT-simulation, with improving target coverage and normal tissue (ex., lung, heart, and spinal cord) sparing. This study suggested that the definitive chemo-radiotherapy with docetaxel, cisplatin, and 5-fluorouracil (i.e., DCF-R) and gating IMRT is tolerable and active in patients with locally advanced mid-esophageal cancer (AEC)

  14. Stereotactic Radiosurgery (SRS) / Stereotactic body radiotherapy (SBRT): Benefit to Irish patients and Irish Healthcare Economy

    LENUS (Irish Health Repository)

    Cagney, DN

    2017-01-01

    Cancer incidence across Europe is projected to rise rapidly over the next decade. This rising cancer incidence is mirrored by increasing use of and indications for stereotactic radiation. This paper seeks to summarize the exponential increase in indications for stereotactic radiotherapy as well as the evolving economic advantages of stereotactic radiosurgery and stereotactic body radiotherapy

  15. Predictors of Radiotherapy Induced Bone Injury (RIBI) after stereotactic lung radiotherapy

    International Nuclear Information System (INIS)

    Taremi, Mojgan; Hope, Andrew; Lindsay, Patricia; Dahele, Max; Fung, Sharon; Purdie, Thomas G; Jaffray, David; Dawson, Laura; Bezjak, Andrea

    2012-01-01

    The purpose of this study was to identify clinical and dosimetric factors associated with radiotherapy induced bone injury (RIBI) following stereotactic lung radiotherapy. Inoperable patients with early stage non-small cell lung cancer, treated with SBRT, who received 54 or 60 Gy in 3 fractions, and had a minimum of 6 months follow up were reviewed. Archived treatment plans were retrieved, ribs delineated individually and treatment plans re-computed using heterogeneity correction. Clinical and dosimetric factors were evaluated for their association with rib fracture using logistic regression analysis; a dose-event curve and nomogram were created. 46 consecutive patients treated between Oct 2004 and Dec 2008 with median follow-up 25 months (m) (range 6 – 51 m) were eligible. 41 fractured ribs were detected in 17 patients; median time to fracture was 21 m (range 7 – 40 m). The mean maximum point dose in non-fractured ribs (n = 1054) was 10.5 Gy ± 10.2 Gy, this was higher in fractured ribs (n = 41) 48.5 Gy ± 24.3 Gy (p < 0.0001). On univariate analysis, age, dose to 0.5 cc of the ribs (D 0.5 ), and the volume of the rib receiving at least 25 Gy (V 25 ), were significantly associated with RIBI. As D 0.5 and V 25 were cross-correlated (Spearman correlation coefficient: 0.57, p < 0.001), we selected D 0.5 as a representative dose parameter. On multivariate analysis, age (odds ratio: 1.121, 95% CI: 1.04 – 1.21, p = 0.003), female gender (odds ratio: 4.43, 95% CI: 1.68 – 11.68, p = 0.003), and rib D 0.5 (odds ratio: 1.0009, 95% CI: 1.0007 – 1.001, p < 0.0001) were significantly associated with rib fracture. Using D 0.5, a dose-event curve was constructed estimating risk of fracture from dose at the median follow up of 25 months after treatment. In our cohort, a 50% risk of rib fracture was associated with a D 0.5 of 60 Gy. Dosimetric and clinical factors contribute to risk of RIBI and both should be included when modeling risk of toxicity. A nomogram is

  16. Predictors of Radiotherapy Induced Bone Injury (RIBI after stereotactic lung radiotherapy

    Directory of Open Access Journals (Sweden)

    Taremi Mojgan

    2012-09-01

    Full Text Available Abstract Background The purpose of this study was to identify clinical and dosimetric factors associated with radiotherapy induced bone injury (RIBI following stereotactic lung radiotherapy. Methods Inoperable patients with early stage non-small cell lung cancer, treated with SBRT, who received 54 or 60 Gy in 3 fractions, and had a minimum of 6 months follow up were reviewed. Archived treatment plans were retrieved, ribs delineated individually and treatment plans re-computed using heterogeneity correction. Clinical and dosimetric factors were evaluated for their association with rib fracture using logistic regression analysis; a dose-event curve and nomogram were created. Results 46 consecutive patients treated between Oct 2004 and Dec 2008 with median follow-up 25 months (m (range 6 – 51 m were eligible. 41 fractured ribs were detected in 17 patients; median time to fracture was 21 m (range 7 – 40 m. The mean maximum point dose in non-fractured ribs (n = 1054 was 10.5 Gy ± 10.2 Gy, this was higher in fractured ribs (n = 41 48.5 Gy ± 24.3 Gy (p 0.5, and the volume of the rib receiving at least 25 Gy (V25, were significantly associated with RIBI. As D0.5 and V25 were cross-correlated (Spearman correlation coefficient: 0.57, p 0.5 as a representative dose parameter. On multivariate analysis, age (odds ratio: 1.121, 95% CI: 1.04 – 1.21, p = 0.003, female gender (odds ratio: 4.43, 95% CI: 1.68 – 11.68, p = 0.003, and rib D0.5 (odds ratio: 1.0009, 95% CI: 1.0007 – 1.001, p  Using D0.5, a dose-event curve was constructed estimating risk of fracture from dose at the median follow up of 25 months after treatment. In our cohort, a 50% risk of rib fracture was associated with a D0.5 of 60 Gy. Conclusions Dosimetric and clinical factors contribute to risk of RIBI and both should be included when modeling risk of toxicity. A nomogram is presented using D0.5, age, and female gender to

  17. Letter to the Editor on 'Single-Arc IMRT?'.

    Science.gov (United States)

    Otto, Karl

    2009-04-21

    In the note 'Single Arc IMRT?' (Bortfeld and Webb 2009 Phys. Med. Biol. 54 N9-20), Bortfeld and Webb present a theoretical investigation of static gantry IMRT (S-IMRT), single-arc IMRT and tomotherapy. Based on their assumptions they conclude that single-arc IMRT is inherently limited in treating complex cases without compromising delivery efficiency. Here we present an expansion of their work based on the capabilities of the Varian RapidArc single-arc IMRT system. Using the same theoretical framework we derive clinically deliverable single-arc IMRT plans based on these specific capabilities. In particular, we consider the range of leaf motion, the ability to rapidly and continuously vary the dose rate and the choice of collimator angle used for delivery. In contrast to the results of Bortfeld and Webb, our results show that single-arc IMRT plans can be generated that closely match the theoretical optimum. The disparity in the results of each investigation emphasizes that the capabilities of the delivery system, along with the ability of the optimization algorithm to exploit those capabilities, are of particular importance in single-arc IMRT. We conclude that, given the capabilities available with the RapidArc system, single-arc IMRT can produce complex treatment plans that are delivered efficiently (in approximately 2 min).

  18. Registration of DRRs and portal images for verification of stereotactic body radiotherapy: a feasibility study in lung cancer treatment

    International Nuclear Information System (INIS)

    Kuenzler, Thomas; Grezdo, Jozef; Bogner, Joachim; Birkfellner, Wolfgang; Georg, Dietmar

    2007-01-01

    Image guidance has become a pre-requisite for hypofractionated radiotherapy where the applied dose per fraction is increased. Particularly in stereotactic body radiotherapy (SBRT) for lung tumours, one has to account for set-up errors and intrafraction tumour motion. In our feasibility study, we compared digitally reconstructed radiographs (DRRs) of lung lesions with MV portal images (PIs) to obtain the displacement of the tumour before irradiation. The verification of the tumour position was performed by rigid intensity based registration and three different merit functions such as the sum of squared pixel intensity differences, normalized cross correlation and normalized mutual information. The registration process then provided a translation vector that defines the displacement of the target in order to align the tumour with the isocentre. To evaluate the registration algorithms, 163 test images were created and subsequently, a lung phantom containing an 8 cm 3 tumour was built. In a further step, the registration process was applied on patient data, containing 38 tumours in 113 fractions. To potentially improve registration outcome, two filter types (histogram equalization and display equalization) were applied and their impact on the registration process was evaluated. Generated test images showed an increase in successful registrations when applying a histogram equalization filter whereas the lung phantom study proved the accuracy of the selected algorithms, i.e. deviations of the calculated translation vector for all test algorithms were below 1 mm. For clinical patient data, successful registrations occurred in about 59% of anterior-posterior (AP) and 46% of lateral projections, respectively. When patients with a clinical target volume smaller than 10 cm 3 were excluded, successful registrations go up to 90% in AP and 50% in lateral projection. In addition, a reliable identification of the tumour position was found to be difficult for clinical target

  19. Registration of DRRs and portal images for verification of stereotactic body radiotherapy: a feasibility study in lung cancer treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kuenzler, Thomas [Department of Radiotherapy and Radiobiology, Medical University Vienna, Vienna (Austria); Grezdo, Jozef [Department of Radiotherapy, St Elisabeth Institute of Oncology, Bratislava (Slovakia); Bogner, Joachim [Department of Radiotherapy and Radiobiology, Medical University Vienna, Vienna (Austria); Birkfellner, Wolfgang [Center for Biomedical Engineering and Physics, Medical University Vienna, Vienna (Austria); Georg, Dietmar [Department of Radiotherapy and Radiobiology, Medical University Vienna, Vienna (Austria)

    2007-04-21

    Image guidance has become a pre-requisite for hypofractionated radiotherapy where the applied dose per fraction is increased. Particularly in stereotactic body radiotherapy (SBRT) for lung tumours, one has to account for set-up errors and intrafraction tumour motion. In our feasibility study, we compared digitally reconstructed radiographs (DRRs) of lung lesions with MV portal images (PIs) to obtain the displacement of the tumour before irradiation. The verification of the tumour position was performed by rigid intensity based registration and three different merit functions such as the sum of squared pixel intensity differences, normalized cross correlation and normalized mutual information. The registration process then provided a translation vector that defines the displacement of the target in order to align the tumour with the isocentre. To evaluate the registration algorithms, 163 test images were created and subsequently, a lung phantom containing an 8 cm{sup 3} tumour was built. In a further step, the registration process was applied on patient data, containing 38 tumours in 113 fractions. To potentially improve registration outcome, two filter types (histogram equalization and display equalization) were applied and their impact on the registration process was evaluated. Generated test images showed an increase in successful registrations when applying a histogram equalization filter whereas the lung phantom study proved the accuracy of the selected algorithms, i.e. deviations of the calculated translation vector for all test algorithms were below 1 mm. For clinical patient data, successful registrations occurred in about 59% of anterior-posterior (AP) and 46% of lateral projections, respectively. When patients with a clinical target volume smaller than 10 cm{sup 3} were excluded, successful registrations go up to 90% in AP and 50% in lateral projection. In addition, a reliable identification of the tumour position was found to be difficult for clinical

  20. Radiotherapy-induced secondary cancer risk for breast cancer: 3D conformal therapy versus IMRT versus VMAT

    International Nuclear Information System (INIS)

    Lee, Boram; Sung, Jiwon; Yoon, Myonggeun; Lee, Sunyoung

    2014-01-01

    This study evaluated the secondary cancer risk to various organs due to radiation treatment for breast cancer. Organ doses to an anthropomorphic phantom were measured using a photoluminescent dosimeter (PLD) for breast cancer treatment with 3D conformal radiation therapy (3D-CRT), intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Cancer risk based on the measured dose was calculated using the BEIR (Biological Effects of Ionizing Radiation) VII models. The secondary dose per treatment dose (50.4 Gy) to various organs ranged from 0.02 to 0.36 Gy for 3D-CRT, but from 0.07 to 8.48 Gy for IMRT and VMAT, indicating that the latter methods are associated with higher secondary radiation doses than 3D-CRT. The result of the homogeneity index in the breast target shows that the dose homogeneity of 3D-CRT was worse than those of IMRT and VMAT. The organ specific lifetime attributable risks (LARs) to the thyroid, contralateral breast and ipsilateral lung per 100 000 population were 0.02, 19.71, and 0.76 respectively for 3D-CRT, much lower than the 0.11, 463.56, and 10.59 respectively for IMRT and the 0.12, 290.32, and 12.28 respectively for VMAT. The overall estimation of LAR indicated that the radiation-induced cancer risk due to breast radiation therapy was lower with 3D-CRT than with IMRT or VMAT. (paper)

  1. SU-G-BRA-10: Marker Free Lung Tumor Motion Tracking by An Active Contour Model On Cone Beam CT Projections for Stereotactic Body Radiation Therapy of Lung Cancer

    International Nuclear Information System (INIS)

    Chao, M; Yuan, Y; Lo, Y; Wei, J

    2016-01-01

    Purpose: To develop a novel strategy to extract the lung tumor motion from cone beam CT (CBCT) projections by an active contour model with interpolated respiration learned from diaphragm motion. Methods: Tumor tracking on CBCT projections was accomplished with the templates derived from planning CT (pCT). There are three major steps in the proposed algorithm: 1) The pCT was modified to form two CT sets: a tumor removed pCT and a tumor only pCT, the respective digitally reconstructed radiographs DRRtr and DRRto following the same geometry of the CBCT projections were generated correspondingly. 2) The DRRtr was rigidly registered with the CBCT projections on the frame-by-frame basis. Difference images between CBCT projections and the registered DRRtr were generated where the tumor visibility was appreciably enhanced. 3) An active contour method was applied to track the tumor motion on the tumor enhanced projections with DRRto as templates to initialize the tumor tracking while the respiratory motion was compensated for by interpolating the diaphragm motion estimated by our novel constrained linear regression approach. CBCT and pCT from five patients undergoing stereotactic body radiotherapy were included in addition to scans from a Quasar phantom programmed with known motion. Manual tumor tracking was performed on CBCT projections and was compared to the automatic tracking to evaluate the algorithm accuracy. Results: The phantom study showed that the error between the automatic tracking and the ground truth was within 0.2mm. For the patients the discrepancy between the calculation and the manual tracking was between 1.4 and 2.2 mm depending on the location and shape of the lung tumor. Similar patterns were observed in the frequency domain. Conclusion: The new algorithm demonstrated the feasibility to track the lung tumor from noisy CBCT projections, providing a potential solution to better motion management for lung radiation therapy.

  2. SU-G-BRA-10: Marker Free Lung Tumor Motion Tracking by An Active Contour Model On Cone Beam CT Projections for Stereotactic Body Radiation Therapy of Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chao, M; Yuan, Y; Lo, Y [The Mount Sinai Medical Center, New York, NY (United States); Wei, J [City College of New York, New York, NY (United States)

    2016-06-15

    Purpose: To develop a novel strategy to extract the lung tumor motion from cone beam CT (CBCT) projections by an active contour model with interpolated respiration learned from diaphragm motion. Methods: Tumor tracking on CBCT projections was accomplished with the templates derived from planning CT (pCT). There are three major steps in the proposed algorithm: 1) The pCT was modified to form two CT sets: a tumor removed pCT and a tumor only pCT, the respective digitally reconstructed radiographs DRRtr and DRRto following the same geometry of the CBCT projections were generated correspondingly. 2) The DRRtr was rigidly registered with the CBCT projections on the frame-by-frame basis. Difference images between CBCT projections and the registered DRRtr were generated where the tumor visibility was appreciably enhanced. 3) An active contour method was applied to track the tumor motion on the tumor enhanced projections with DRRto as templates to initialize the tumor tracking while the respiratory motion was compensated for by interpolating the diaphragm motion estimated by our novel constrained linear regression approach. CBCT and pCT from five patients undergoing stereotactic body radiotherapy were included in addition to scans from a Quasar phantom programmed with known motion. Manual tumor tracking was performed on CBCT projections and was compared to the automatic tracking to evaluate the algorithm accuracy. Results: The phantom study showed that the error between the automatic tracking and the ground truth was within 0.2mm. For the patients the discrepancy between the calculation and the manual tracking was between 1.4 and 2.2 mm depending on the location and shape of the lung tumor. Similar patterns were observed in the frequency domain. Conclusion: The new algorithm demonstrated the feasibility to track the lung tumor from noisy CBCT projections, providing a potential solution to better motion management for lung radiation therapy.

  3. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  4. Intensity-modulated stereotactic radiosurgery using dynamic micro-multileaf collimation

    International Nuclear Information System (INIS)

    Benedict, Stanley H.; Cardinale, Robert M.; Wu Qiuwen; Zwicker, Robert D.; Broaddus, William C.; Mohan, Radhe

    2001-01-01

    Purpose: The implementation of dynamic leaf motion on a micro-multileaf collimator system provides the capability for intensity-modulated stereotactic radiosurgery (IMSRS), and the consequent potential for improved dose distributions for irregularly shaped tumor volumes adjacent to critical organs. This study explores the use of IMSRS to provide improved tumor coverage and normal tissue sparing for small cranial tumors relative to plans based on multiple fixed uniform-intensity beams or traditional circular collimator arc-based stereotactic techniques. Methods and Materials: Four patient cases involving small brain lesions are presented and analyzed. The cases were chosen to include a representative selection of target shapes, number of targets, and adjacent critical areas. Patient plans generated for these comparisons include standard arcs with multiple circular collimators, and fixed noncoplanar static fields with uniform-intensity beams and IMSRS. Parameters used for evaluation of the plans include the percentage of irradiated volume to tumor volume (PITV), normal tissue dose-volume histograms, and dose-homogeneity ratios. All IMSRS plans were computed using previously established IMRT techniques adapted for use with the BrainLAB M3 micro-multileaf collimator. The algorithms comprising the IMRT system for optimization of intensity distributions and conversion into leaf trajectories of the BrainLab M3 were developed at our institution. The ADAC Pinnacle 3 radiation treatment-planning system was used for dose calculations and for input of contours for target volumes and normal critical structures. Results: For all cases, the IMSRS plans showed a high degree of conformity of the dose distribution with the target shape. The IMSRS plans provided either (1) a smaller volume of normal tissue irradiated to significant dose levels, generally taken as doses greater than 50% of the prescription, or (2) a lower dose to an important adjacent critical organ. The reduction in

  5. Histologic Subtype in Core Lung Biopsies of Early-Stage Lung Adenocarcinoma is a Prognostic Factor for Treatment Response and Failure Patterns After Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Leeman, Jonathan E.; Rimner, Andreas [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Montecalvo, Joseph [Department of Pathology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Hsu, Meier; Zhang, Zhigang [Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Reibnitz, Donata von; Panchoo, Kelly [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Yorke, Ellen [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Adusumilli, Prasad S. [Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Travis, William [Department of Pathology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Wu, Abraham J., E-mail: wua@mskcc.org [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States)

    2017-01-01

    Purpose: Stereotactic body radiation therapy (SBRT) has emerged as an effective treatment for early-stage lung cancer. The histologic subtype of surgically resected lung adenocarcinoma is recognized as a prognostic factor, with the presence of solid or micropapillary patterns predicting poor outcomes. We describe the outcomes after SBRT for early-stage lung adenocarcinoma stratified by histologic subtype. Methods and Materials: We identified 119 consecutive patients (124 lesions) with stage I to IIA lung adenocarcinoma who had undergone definitive SBRT at our institution from August 2008 to August 2015 and had undergone core biopsy. Histologic subtyping was performed according to the 2015 World Health Organization classification. Of the 124 tumors, 37 (30%) were a high-risk subtype, defined as containing a component of solid and/or micropapillary pattern. The cumulative incidences of local, nodal, regional, and distant failure were compared between the high-risk and non–high-risk adenocarcinoma subtypes using Gray's test, and multivariable-adjusted hazard ratios (HRs) were estimated from propensity score–weighted Cox regression models. Results: The median follow-up for the entire cohort was 17 months and for surviving patients was 21 months. The 1-year cumulative incidence of and adjusted HR for local, nodal, regional, and distant failure in high-risk versus non–high-risk lesions was 7.3% versus 2.7% (HR 16.8; 95% confidence interval [CI] 3.5-81.4), 14.8% versus 2.6% (HR 3.8; 95% CI 0.95-15.0), 4.0% versus 1.2% (HR 20.9; 95% CI 2.3-192.3), and 22.7% versus 3.6% (HR 6.9; 95% CI 2.2-21.1), respectively. No significant difference was seen with regard to overall survival. Conclusions: The outcomes after SBRT for early-stage adenocarcinoma of the lung correlate highly with histologic subtype, with micropapillary and solid tumors portending significantly higher rates of locoregional and metastatic progression. In this context, the histologic subtype

  6. Dosimetry tools and techniques for IMRT

    International Nuclear Information System (INIS)

    Low, Daniel A.; Moran, Jean M.; Dempsey, James F.; Dong Lei; Oldham, Mark

    2011-01-01

    Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly measuring commissioning data and quality assurance (QA) radiation dose distributions. This report provides a comprehensive overview of how dosimeters, phantoms, and dose distribution analysis techniques should be used to support the commissioning and quality assurance requirements of an IMRT program. The proper applications of each dosimeter are described along with the limitations of each system. Point detectors, arrays, film, and electronic portal imagers are discussed with respect to their proper use, along with potential applications of 3D dosimetry. Regardless of the IMRT technique utilized, some situations require the use of multiple detectors for the acquisition of accurate commissioning data. The overall goal of this task group report is to provide a document that aids the physicist in the proper selection and use of the dosimetry tools available for IMRT QA and to provide a resource for physicists that describes dosimetry measurement techniques for purposes of IMRT commissioning and measurement-based characterization or verification of IMRT treatment plans. This report is not intended to provide a comprehensive review of commissioning and QA procedures for IMRT. Instead, this report focuses on the aspects of metrology, particularly the practical aspects of measurements that are unique to IMRT. The metrology of IMRT concerns the application of measurement instruments and their suitability, calibration, and quality control of measurements. Each of the dosimetry measurement tools has limitations that need to be considered when incorporating them into a commissioning process or a comprehensive QA program. For example, routine quality assurance procedures require the use of robust field dosimetry systems. These often exhibit limitations with respect to spatial resolution or energy response and need to themselves be commissioned against more established dosimeters. A chain of

  7. Radiographic and metabolic response rates following image-guided stereotactic radiotherapy for lung tumors

    International Nuclear Information System (INIS)

    Mohammed, Nasiruddin; Grills, Inga S.; Wong, Ching-Yee Oliver; Galerani, Ana Paula; Chao, Kenneth; Welsh, Robert; Chmielewski, Gary; Yan Di; Kestin, Larry L.

    2011-01-01

    Purpose: To evaluate radiographic and metabolic response after stereotactic body radiotherapy (SBRT) for early lung tumors. Materials and methods: Thirty-nine tumors were treated prospectively with SBRT (dose = 48-60 Gy, 4-5 Fx). Thirty-six cases were primary NSCLC (T1N0 = 67%; T2N0 = 25%); three cases were solitary metastases. Patients were followed using CT and PET at 6, 16, and 52 weeks post-SBRT, with CT follow-up thereafter. RECIST and EORTC criteria were used to evaluate CT and PET responses. Results: At median follow-up of 9 months (0.4-26), RECIST complete response (CR), partial response (PR), and stable disease (SD) rates were 3%, 43%, 54% at 6 weeks; 15%, 38%, 46% at 16 weeks; 27%, 64%, 9% at 52 weeks. Mean baseline tumor volume was reduced by 46%, 70%, 87%, and 96%, respectively at 6, 16, 52, and 72 weeks. Mean baseline maximum standardized uptake value (SUV) was 8.3 (1.1-20.3) and reduced to 3.4, 3.0, and 3.7 at 6, 16, and 52 weeks after SBRT. EORTC metabolic CR/PR, SD, and progressive disease rates were 67%, 22%, 11% at 6 weeks; 86%, 10%, 3% at 16 weeks; 95%, 5%, 0% at 52 weeks. Conclusions: SBRT yields excellent RECIST and EORTC based response. Metabolic response is rapid however radiographic response occurs even after 1-year post treatment.

  8. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    International Nuclear Information System (INIS)

    Wiezorek, Tilo; Schubert, Kai; Wagner, Daniela; Wendt, Thomas G; Brachwitz, Tim; Georg, Dietmar; Blank, Eyck; Fotina, Irina; Habl, Gregor; Kretschmer, Matthias; Lutters, Gerd; Salz, Henning

    2011-01-01

    Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx) using the following treatment planning systems (TPS) for rotational IMRT: Monaco (ELEKTA VMAT solution), Eclipse (Varian RapidArc solution) and HiArt for the helical tomotherapy (Tomotherapy). Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V 5Gy ). Additionally, the cumulative monitor units (MUs) and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V 5Gy values were lowest for the sliding window IMRT technique (3499 ccm) and largest for RapidArc (5480 ccm). The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. All IMRT delivery technologies with their associated TPS

  9. Limited parameter set IMRT for carcinoma breast

    International Nuclear Information System (INIS)

    Gopinath, M.; Sharma, Sanjiv; Vivek, T.R.; Suparna; Deka, Preeti; Manikandan; Giriraj

    2008-01-01

    Post operative radiotherapy after breast conservation surgery is an effective and widely accepted treatment modality in early stage breast cancer. The treatment is usually performed using two wedged tangential photon beams. The disadvantage of this technique is significant dose inhomogeneity as large as 15-20% in the superior and inferior regions of the breast due to lesser transmission thickness and in the medial and lateral aspect of the breast due to lower attenuation of lung tissue in the field. The aim of the study is to modify the conventional wedged tangential pair to achieve a more homogeneous dose distribution and a reduction in acute toxicity and improved cosmetic result. A comparative study is done between the conventional wedged technique and limited parameter set IMRT

  10. Protocol for the isotoxic intensity modulated radiotherapy (IMRT) in stage III non-small cell lung cancer (NSCLC): a feasibility study.

    Science.gov (United States)

    Haslett, Kate; Franks, Kevin; Hanna, Gerard G; Harden, Susan; Hatton, Matthew; Harrow, Stephen; McDonald, Fiona; Ashcroft, Linda; Falk, Sally; Groom, Nicki; Harris, Catherine; McCloskey, Paula; Whitehurst, Philip; Bayman, Neil; Faivre-Finn, Corinne

    2016-04-15

    The majority of stage III patients with non-small cell lung cancer (NSCLC) are unsuitable for concurrent chemoradiotherapy, the non-surgical gold standard of care. As the alternative treatment options of sequential chemoradiotherapy and radiotherapy alone are associated with high local failure rates, various intensification strategies have been employed. There is evidence to suggest that altered fractionation using hyperfractionation, acceleration, dose escalation, and individualisation may be of benefit. The MAASTRO group have pioneered the concept of 'isotoxic' radiotherapy allowing for individualised dose escalation using hyperfractionated accelerated radiotherapy based on predefined normal tissue constraints. This study aims to evaluate whether delivering isotoxic radiotherapy using intensity modulated radiotherapy (IMRT) is achievable. Isotoxic IMRT is a multicentre feasibility study. From June 2014, a total of 35 patients from 7 UK centres, with a proven histological or cytological diagnosis of inoperable NSCLC, unsuitable for concurrent chemoradiotherapy will be recruited. A minimum of 2 cycles of induction chemotherapy is mandated before starting isotoxic radiotherapy. The dose of radiation will be increased until one or more of the organs at risk tolerance or the maximum dose of 79.2 Gy is reached. The primary end point is feasibility, with accrual rates, local control and overall survival our secondary end points. Patients will be followed up for 5 years. The study has received ethical approval (REC reference: 13/NW/0480) from the National Research Ethics Service (NRES) Committee North West-Greater Manchester South. The trial is conducted in accordance with the Declaration of Helsinki and Good Clinical Practice (GCP). The trial results will be published in a peer-reviewed journal and presented internationally. NCT01836692; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence

  11. Dosimetric comparison of deep inspiration breath hold and free breathing technique in stereotactic body radiotherapy for localized lung tumor using Flattening Filter Free beam

    Science.gov (United States)

    Mani, Karthick Raj; Bhuiyan, Md. Anisuzzaman; Alam, Md. Mahbub; Ahmed, Sharif; Sumon, Mostafa Aziz; Sengupta, Ashim Kumar; Rahman, Md. Shakilur; Azharul Islam, Md. S. M.

    2018-03-01

    Aim: To compare the dosimetric advantage of stereotactic body radiotherapy (SBRT) for localized lung tumor between deep inspiration breath hold technique and free breathing technique. Materials and methods: We retrospectively included ten previously treated lung tumor patients in this dosimetric study. All the ten patients underwent CT simulation using 4D-CT free breathing (FB) and deep inspiration breath hold (DIBH) techniques. Plans were created using three coplanar full modulated arc using 6 MV flattening filter free (FFF) bream with a dose rate of 1400 MU/min. Same dose constraints for the target and the critical structures for a particular patient were used during the plan optimization process in DIBH and FB datasets. We intend to deliver 50 Gy in 5 fractions for all the patients. For standardization, all the plans were normalized at target mean of the planning target volume (PTV). Doses to the critical structures and targets were recorded from the dose volume histogram for evaluation. Results: The mean right and left lung volumes were inflated by 1.55 and 1.60 times in DIBH scans compared to the FB scans. The mean internal target volume (ITV) increased in the FB datasets by 1.45 times compared to the DIBH data sets. The mean dose followed by standard deviation (x¯ ± σx¯) of ipsilateral lung for DIBH-SBRT and FB-SBRT plans were 7.48 ± 3.57 (Gy) and 10.23 ± 4.58 (Gy) respectively, with a mean reduction of 36.84% in DIBH-SBRT plans. Ipsilateral lung were reduced to 36.84% in DIBH plans compared to FB plans. Conclusion: Significant dose reduction in ipsilateral lung due to the lung inflation and target motion restriction in DIBH-SBRT plans were observed compare to FB-SBRT. DIBH-SBRT plans demonstrate superior dose reduction to the normal tissues and other critical structures.

  12. Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 03: The Potential Benefit Of Esophageal Sparing During Palliative Radiotherapy For Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Granton, Patrick V.; Palma, David A.; Louie, Alexander V. [Department of Radiation Oncology, London Health Sciences Centre, Department of Radiation Oncology, London Health Sciences Centre, Department of Radiation Oncology, London Health Sciences Centre (United Kingdom)

    2016-08-15

    Puropose: Palliative radiotherapy is an effective technique to alleviate systems of disease burden in late-stage lung cancer patients. Previous randomized controlled studies demonstrated a survival benefit in patients with good performance status at radiation doses of 35Gy10 or greater but with an increased incidence of esophagitis. The objective of this planning study was to assess the potential impact of esophageal-sparing IMRT (ES-IMRT) compared to the current standard of care using parallel-opposed pair beams (POP). Methods: In this study, 15 patients with lung cancer treated to a dose of 30Gy in 10 fractions between August 2015 and January 2016 were identified. Radiation treatment plans were optimized using ES-IMRT by limiting the max esophagus point dose to 24Gy. Using published Lyman-Kutcher-Burman normal tissue complication probabilities (LKB-NTCP) models, both plans were evaluated for the likelihood of esophagitis (≥ grade 2) and pneumonitis (≥ grade 2). Results: Using ES-IMRT, the median esophageal and lung mean doses reduced from 16 and 8Gy to 7 and 7Gy, respectively. Using the LKB models, the theoretical probability of symptomatic esophagitis and pneumonitis reduced from 13 to 1%, and from 5 to 3%, respectively. The median NTD mean for the GTV and PTV of the clinically approved POP plans compared to the ES-IMRT plans were similar. Conclusions: Advanced radiotherapy techniques such as ES-IMRT may have clinical utility in reducing treatment-related toxicity in advanced lung cancer patients. Our data suggests that the rate of esophagitis can be reduced without compromising tumour control.

  13. Stereotactic Body Radiotherapy for Metastatic Lung Cancer as Oligo-Recurrence: An Analysis of 42 Cases

    Directory of Open Access Journals (Sweden)

    Wataru Takahashi

    2012-01-01

    Full Text Available Purpose. To investigate the outcome and toxicity of stereotactic body radiotherapy (SBRT in patients with oligo-recurrence cancer in the lung (ORCL. Methods and Materials. A retrospective review of 42 patients with ORCL who underwent SBRT in our two hospitals was conducted. We evaluated the outcome and adverse effects after SBRT for ORCL. Results. All patients finished their SBRT course without interruptions of toxicity reasons. The median follow-up period was 20 months (range, 1–90 months. The 2-year local control rate and overall survival were 87% (95% CI, 75–99% and 65% (95% CI, 48–82%. As for prognostic factor, the OS of patients with a short disease-free interval (DFI months, between the initial therapy and SBRT for ORCL, was significantly worse than the OS of long DFI months (. The most commonly observed late effect was radiation pneumonitis. One patient had grade 4 gastrointestinal toxicity (perforation of gastric tube. No other ≧ grade 3 acute and late adverse events occurred. There were no treatment-related deaths during this study. Conclusions. In patients with ORCL, radical treatment with SBRT is safe and provides a chance for long-term survival by offering favorable local control.

  14. A national dosimetric audit of IMRT

    International Nuclear Information System (INIS)

    Budgell, Geoff; Berresford, Joe; Trainer, Michael; Bradshaw, Ellie; Sharpe, Peter; Williams, Peter

    2011-01-01

    Background and purpose: A dosimetric audit of IMRT has been carried out within the UK between June 2009 and March 2010 in order to provide an independent check of safe implementation and to identify problems in the modelling and delivery of IMRT. Methods and materials: A mail based audit involving film and alanine dosimeters was utilized. Measurements were made for each individual field in an IMRT plan isocentrically in a flat water-equivalent phantom at a depth of 5 cm. The films and alanine dosimeters were processed and analysed centrally; additional ion chamber measurements were made by each participating centre. Results: 57 of 62 centres participated, with a total of 78 plans submitted. For the film measurements, all 176 fields from the less complex IMRT plans (including prostate and breast plans) achieved over 95% pixels passing a gamma criterion of 3%/3 mm within the 20% isodose. For the more complex IMRT plans (mainly head and neck) 8/245 fields (3.3%) achieved less than 95% pixels passing a 4%/4 mm gamma criterion. Of the alanine measurements, 4/78 (5.1%) of the measurements differed by >5% from the dose predicted by the treatment planning system. Three of these were large deviations of -77.1%, -29.1% and 14.1% respectively. Excluding the three measurements outside 10%, the mean difference was 0.05% with a standard deviation of 1.5%. The out of tolerance results have been subjected to further investigations. Conclusions: A dosimetric audit has been successfully carried out of IMRT implementation by over 90% of UK radiotherapy departments. The audit shows that modelling and delivery of IMRT is accurate, suggesting that the implementation of IMRT has been carried out safely.

  15. Proton Arc Reduces Range Uncertainty Effects and Improves Conformality Compared With Photon Volumetric Modulated Arc Therapy in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Seco, Joao, E-mail: jseco@partners.org [Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Gu, Guan; Marcelos, Tiago; Kooy, Hanne; Willers, Henning [Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2013-09-01

    Purpose: To describe, in a setting of non-small cell lung cancer (NSCLC), the theoretical dosimetric advantages of proton arc stereotactic body radiation therapy (SBRT) in which the beam penumbra of a rotating beam is used to reduce the impact of range uncertainties. Methods and Materials: Thirteen patients with early-stage NSCLC treated with proton SBRT underwent repeat planning with photon volumetric modulated arc therapy (Photon-VMAT) and an in-house-developed arc planning approach for both proton passive scattering (Passive-Arc) and intensity modulated proton therapy (IMPT-Arc). An arc was mimicked with a series of beams placed at 10° increments. Tumor and organ at risk doses were compared in the context of high- and low-dose regions, represented by volumes receiving >50% and <50% of the prescription dose, respectively. Results: In the high-dose region, conformality index values are 2.56, 1.91, 1.31, and 1.74, and homogeneity index values are 1.29, 1.22, 1.52, and 1.18, respectively, for 3 proton passive scattered beams, Passive-Arc, IMPT-Arc, and Photon-VMAT. Therefore, proton arc leads to a 30% reduction in the 95% isodose line volume to 3-beam proton plan, sparing surrounding organs, such as lung and chest wall. For chest wall, V30 is reduced from 21 cm{sup 3} (3 proton beams) to 11.5 cm{sup 3}, 12.9 cm{sup 3}, and 8.63 cm{sup 3} (P=.005) for Passive-Arc, IMPT-Arc, and Photon-VMAT, respectively. In the low-dose region, the mean lung dose and V20 of the ipsilateral lung are 5.01 Gy(relative biological effectiveness [RBE]), 4.38 Gy(RBE), 4.91 Gy(RBE), and 5.99 Gy(RBE) and 9.5%, 7.5%, 9.0%, and 10.0%, respectively, for 3-beam, Passive-Arc, IMPT-Arc, and Photon-VMAT, respectively. Conclusions: Stereotactic body radiation therapy with proton arc and Photon-VMAT generate significantly more conformal high-dose volumes than standard proton SBRT, without loss of coverage of the tumor and with significant sparing of nearby organs, such as chest wall. In addition

  16. Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors.

    Science.gov (United States)

    Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi

    2017-11-01

    This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. Developing and evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose

    International Nuclear Information System (INIS)

    Schuring, Danny; Hurkmans, Coen W

    2008-01-01

    To investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs. For 26 patients with stage-I NSCLC treatment plans were optimized with unit density (UD), an equivalent pathlength algorithm (EPL), and a collapsed-cone (CC) algorithm, prescribing 60 Gy to the PTV. After optimization the first two plans were recalculated with the more accurate CC algorithm. Dose parameters were compared for the three different optimized plans. Dose to the target and OARs was evaluated for the recalculated plans and compared with the planned values. For the CC algorithm dose constraints for the ratio of the 50% isodose volume and the PTV, and the V 20 Gy are harder to fulfill. After recalculation of the UD and EPL plans large variations in the dose to the PTV were observed. For the unit density plans, the dose to the PTV varied from 42.1 to 63.4 Gy for individual patients. The EPL plans all overestimated the PTV dose (average 48.0 Gy). For the lungs, the recalculated V 20 Gy was highly correlated to the planned value, and was 12% higher for the UD plans (R 2 = 0.99), and 15% lower for the EPL plans (R 2 = 0.96). Inhomogeneity corrections have a large influence on the dose delivered to the PTV and OARs for SBRT of lung tumors. A simple rescaling of the dose to the PTV is not possible, implicating that accurate dose calculations are necessary for these treatment plans in order to prevent large discrepancies between planned and actually delivered doses to individual patients

  18. SU-E-T-573: Normal Tissue Dose Effect of Prescription Isodose Level Selection in Lung Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Zhang, Q; Lei, Y; Zheng, D; Zhu, X; Wahl, A; Lin, C; Zhou, S; Zhen, W

    2015-01-01

    Purpose: To evaluate dose fall-off in normal tissue for lung stereotactic body radiation therapy (SBRT) cases planned with different prescription isodose levels (IDLs), by calculating the dose dropping speed (DDS) in normal tissue on plans computed with both Pencil Beam (PB) and Monte-Carlo (MC) algorithms. Methods: The DDS was calculated on 32 plans for 8 lung SBRT patients. For each patient, 4 dynamic conformal arc plans were individually optimized for prescription isodose levels (IDL) ranging from 60% to 90% of the maximum dose with 10% increments to conformally cover the PTV. Eighty non-overlapping rind structures each of 1mm thickness were created layer by layer from each PTV surface. The average dose in each rind was calculated and fitted with a double exponential function (DEF) of the distance from the PTV surface, which models the steep- and moderate-slope portions of the average dose curve in normal tissue. The parameter characterizing the steep portion of the average dose curve in the DEF quantifies the DDS in the immediate normal tissue receiving high dose. Provided that the prescription dose covers the whole PTV, a greater DDS indicates better normal tissue sparing. The DDS were compared among plans with different prescription IDLs, for plans computed with both PB and MC algorithms. Results: For all patients, the DDS was found to be the lowest for 90% prescription IDL and reached a highest plateau region for 60% or 70% prescription. The trend was the same for both PB and MC plans. Conclusion: Among the range of prescription IDLs accepted by lung SBRT RTOG protocols, prescriptions to 60% and 70% IDLs were found to provide best normal tissue sparing

  19. SU-F-T-106: A Dosimetric Study of Intensity Modulated Radiation Therapy to Decrease Radiation Dose to the Thoracic Vertebral Bodies in Patients Receiving Concurrent Chemoradiation for Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    DiCostanzo, Dominic; Barney, Christian L.; Bazan, Jose G. [The Ohio State University, Columbus, Ohio (United States)

    2016-06-15

    Purpose: Recent clinical studies have shown a correlation between radiation dose to the thoracic vertebral bodies (TVB) and the development of hematologic toxicity (HT) in patients receiving chemoradiation (CRT) for lung cancer (LuCa). The feasibility of a bone-marrow sparing (BMS) approach in this group of patients is unknown. We hypothesized that radiation dose to the TVB can be reduced with an intensity modulated radiation therapy(IMRT)/volumetric modulated arc radiotherapy(VMAT) without affecting plan quality. Methods: We identified LuCa cases treated with curative intent CRT using IMRT/VMAT from 4/2009 to 2/2015. The TVBs from T1–T10 were retrospectively contoured. No constraints were placed on the TVB structure initially. A subset were re-planned with BMS-IMRT/VMAT with an objective or reducing the mean TVB dose to <23 Gy. The following data were collected on the initial and BMS plans: mean dose to planning target volume (PTV), lungs-PTV, esophagus, heart; lung V20; cord max dose. Pairwise comparisons were performed using the signed rank test. Results: 94 cases received CRT with IMRT/VMAT. We selected 11 cases (7 IMRT, 4 VMAT) with a range of initial mean TVB doses (median 35.7 Gy, range 18.9–41.4 Gy). Median prescription dose was 60 Gy. BMS-IMRT/VMAT significantly reduced the mean TVB dose by a median of 10.2 Gy (range, 1.0–16.7 Gy, p=0.001) and reduced the cord max dose by 2.9 Gy (p=0.014). BMS-IMRT/VMAT had no impact on lung mean (median +17 cGy, p=0.700), lung V20 (median +0.5%, p=0.898), esophagus mean (median +13 cGy, p=1.000) or heart mean (median +16 cGy, p=0.365). PTV-mean dose was not affected by BMS-IMRT/VMAT (median +13 cGy, p=0.653). Conclusion: BMS-IMRT/VMAT was able to significantly reduce radiation dose to the TVB without compromising plan quality. Prospective evaluation of BMS-IMRT/VMAT in patients receiving CRT for LuCa is warranted to determine if this approach results in clinically significant reductions in HT.

  20. Clinical Analysis of stereotactic body radiation therapy using extracranial gamma knife for patients with mainly bulky inoperable early stage non-small cell lung carcinoma

    Directory of Open Access Journals (Sweden)

    Tang Hanjun

    2011-07-01

    Full Text Available Abstract Purpose To evaluate the clinical efficacy and toxicity of stereotactic body radiation therapy (SBRT using extracranial gamma knife in patients with mainly bulky inoperable early stage non-small cell lung carcinoma (NSCLC. Materials and methods A total of 43 medically inoperable patients with mainly bulky Stage I/II NSCLC received SBRT using gamma knife were reviewed. The fraction dose and the total dose were determined by the radiation oncologist according to patients' general status, tumor location, tumor size and the relationship between tumor and nearby organ at risk (OAR. The total dose of 34~47.5 Gy was prescribed in 4~12 fractions, 3.5~10 Gy per fraction, one fraction per day or every other day. The therapeutic efficacy and toxicity were evaluated. Results The median follow-up was 22 months (range, 3-102 months. The local tumor response rate was 95.35%, with CR 18.60% (8/43 and PR 76.74% (33/43, respectively. The local control rates at 1, 2, 3, 5 years were 77.54%, 53.02%, 39.77%, and 15.46%, respectively, while the 1- and 2-year local control rates were 75% and 60% for tumor ≤3 cm; 84% and 71% for tumor sized 3~5 cm; 55% and 14.6% for tumor sized 5~7 cm; and 45%, 21% in those with tumor size of >7 cm. The overall survival rate at 1, 2, 3, 5 years were 92.04%, 78.04%, 62.76%, 42.61%, respectively. The toxicity of stereotactic radiation therapy was grade 1-2. Clinical stages were significantly important factor in local control of lung tumors (P = 0.000. Both clinical stages (P = 0.015 and chemotherapy (P = 0.042 were significantly important factors in overall survival of lung tumors. Conclusion SBRT is an effective and safe therapy for medically inoperable patients with early stage NSCLC. Clinical stage was the significant prognostic factors for both local tumor control and overall survival. The toxicity is mild. The overall local control for bulky tumors is poor. Tumor size is a poor prognostic factor, and the patients for

  1. A margin-based analysis of the dosimetric impact of motion on step-and-shoot IMRT lung plans

    International Nuclear Information System (INIS)

    Waghorn, Benjamin J; Shah, Amish P; Rineer, Justin M; Langen, Katja M; Meeks, Sanford L

    2014-01-01

    Intrafraction motion during step-and-shoot (SNS) IMRT is known to affect the target dosimetry by a combination of dose blurring and interplay effects. These effects are typically managed by adding a margin around the target. A quantitative analysis was performed, assessing the relationship between target motion, margin size, and target dosimetry with the goal of introducing new margin recipes. A computational algorithm was used to calculate 1,174 motion-encoded dose distributions and DVHs within the patient’s CT dataset. Sinusoidal motion tracks were used simulating intrafraction motion for nine lung tumor patients, each with multiple margin sizes. D 95% decreased by less than 3% when the maximum target displacement beyond the margin experienced motion less than 5 mm in the superior-inferior direction and 15 mm in the anterior-posterior direction. For target displacements greater than this, D 95% decreased rapidly. Targets moving in excess of 5 mm outside the margin can cause significant changes to the target. D 95% decreased by up to 20% with target motion 10 mm outside the margin, with underdosing primarily limited to the target periphery. Multi-fractionated treatments were found to exacerbate target under-coverage. Margins several millimeters smaller than the maximum target displacement provided acceptable motion protection, while also allowing for reduced normal tissue morbidity

  2. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    Directory of Open Access Journals (Sweden)

    Lutters Gerd

    2011-02-01

    Full Text Available Abstract Background Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Methods Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx using the following treatment planning systems (TPS for rotational IMRT: Monaco (ELEKTA VMAT solution, Eclipse (Varian RapidArc solution and HiArt for the helical tomotherapy (Tomotherapy. Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V5Gy. Additionally, the cumulative monitor units (MUs and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Results Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V5Gy values were lowest for the sliding window IMRT technique (3499 ccm and largest for RapidArc (5480 ccm. The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. Conclusions All

  3. A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes

    Energy Technology Data Exchange (ETDEWEB)

    Michalski, Andrea [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Central Coast Cancer Centre, Gosford Hospital, Gosford, New South Wales (Australia); Atyeo, John, E-mail: john.atyeo@sydney.edu.au [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Cox, Jennifer [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia); Rinks, Marianne [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Radiation Oncology, Cancer Services, Illawarra Shoalhaven Local Health District, Wollongong, New South Wales (Australia); Morgia, Marita; Lamoury, Gillian [Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia)

    2014-07-01

    Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. All patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D

  4. Poster – 12: Radiological assessment of the secondary barrier shielding for IMRT treatments delivered through patient inhomogeneities

    International Nuclear Information System (INIS)

    Haseeb, Syed Abdul; Ahmad, Syed Bilal; Mirza, Sikander Majid

    2016-01-01

    Purpose: To assess the impact of radiation treatment delivery through patient inhomogeneities on the secondary barrier shielding requirements in IMRT treatments using Monte Carlo Simulations. Materials and Methods: Scatter factors were calculated at a distance of 1m from the center of a virtual phantom in Geant4.10.01. Phantom (30×30×30 cm 3 ) was inserted with lung (30×30×8 cm 3 ), stainless steel (5×5×5 cm 3 ) and aluminum (5×5×5 cm 3 ) to represent the inhomogeneities. Scatter factor was defined according to the NCRP-151 recommendations and was calculated for angles of 3° to 120° with respect to the beam’s central axis. A virtual radiation source, with energy sampled from a histogram representing 6 MV FFF beam, was used for irradiation with a field size of 15×15 cm 2 and SSD of 100 cm. Results: Irradiation through the inhomogeneity affects the patient scattered dose. For high Z material inhomogeneities the scattered dose is reduced due to significant attenuation of the primary radiation. On the other hand if the inhomogeneity is a low Z material such as lung the scattered dose is higher by a maximum of 26%. The average increase in scatter factors for the lung phantom was 17% for angles between 3° and 63° compared to the homogeneous water phantom. Conclusions: In IMRT type treatments delivered through low density patient inhomogeneities (lung) the scattered dose increases significantly. Considering a large proportion of patients receiving radiation therapy for lung cancers the increase in the scattered dose should be incorporated in the shielding calculations for the secondary barriers.

  5. SU-E-T-427: Feasibility Study for Evaluation of IMRT Dose Distribution Using Geant4-Based Automated Algorithms

    International Nuclear Information System (INIS)

    Choi, H; Shin, W; Testa, M; Min, C; Kim, J

    2015-01-01

    Purpose: For intensity-modulated radiation therapy (IMRT) treatment planning validation using Monte Carlo (MC) simulations, a precise and automated procedure is necessary to evaluate the patient dose distribution. The aim of this study is to develop an automated algorithm for IMRT simulations using DICOM files and to evaluate the patient dose based on 4D simulation using the Geant4 MC toolkit. Methods: The head of a clinical linac (Varian Clinac 2300 IX) was modeled in Geant4 along with particular components such as the flattening filter and the multi-leaf collimator (MLC). Patient information and the position of the MLC were imported from the DICOM-RT interface. For each position of the MLC, a step- and-shoot technique was adopted. PDDs and lateral profiles were simulated in a water phantom (50×50×40 cm 3 ) and compared to measurement data. We used a lung phantom and MC-dose calculations were compared to the clinical treatment planning used at the Seoul National University Hospital. Results: In order to reproduce the measurement data, we tuned three free parameters: mean and standard deviation of the primary electron beam energy and the beam spot size. These parameters for 6 MV were found to be 5.6 MeV, 0.2378 MeV and 1 mm FWHM respectively. The average dose difference between measurements and simulations was less than 2% for PDDs and radial profiles. The lung phantom study showed fairly good agreement between MC and planning dose despite some unavoidable statistical fluctuation. Conclusion: The current feasibility study using the lung phantom shows the potential for IMRT dose validation using 4D MC simulations using Geant4 tool kits. This research was supported by Korea Institute of Nuclear safety and Development of Measurement Standards for Medical Radiation funded by Korea research Institute of Standards and Science. (KRISS-2015-15011032)

  6. Time and dose-related changes in lung perfusion after definitive radiotherapy for NSCLC

    DEFF Research Database (Denmark)

    Farr, Katherina P; Khalil, Azza A; Møller, Ditte S

    2018-01-01

    BACKGROUND AND PURPOSE: To examine radiation-induced changes in regional lung perfusion per dose level in 58 non-small-cell lung cancer (NSCLC) patients treated with intensity-modulated radiotherapy (IMRT). MATERIAL AND METHODS: NSCLC patients receiving chemo-radiotherapy (RT) of minimum 60 Gy we...

  7. Comparison of anisotropic aperture based intensity modulated radiotherapy with 3D-conformal radiotherapy for the treatment of large lung tumors.

    Science.gov (United States)

    Simeonova, Anna; Abo-Madyan, Yasser; El-Haddad, Mostafa; Welzel, Grit; Polednik, Martin; Boggula, Ramesh; Wenz, Frederik; Lohr, Frank

    2012-02-01

    IMRT allows dose escalation for large lung tumors, but respiratory motion may compromise delivery. A treatment plan that modulates fluence predominantly in the transversal direction and leaves the fluence identical in the direction of the breathing motion may reduce this problem. Planning-CT-datasets of 20 patients with Stage I-IV non small cell lung cancer (NSCLC) formed the basis of this study. A total of two IMRT plans and one 3D plan were created for each patient. Prescription dose was 60 Gy to the CTV and 70 Gy to the GTV. For the 3D plans an energy of 18 MV photons was used. IMRT plans were calculated for 6 MV photons with 13 coplanar and with 17 noncoplanar beams. Robustness of the used method of anisotropic modulation toward breathing motion was tested in a 13-field IMRT plan. As a consequence of identical prescription doses, mean target doses were similar for 3D and IMRT. Differences between 3D and 13- and 17-field IMRT were significant for CTV Dmin (43 Gy vs. 49.1 Gy vs. 48.6 Gy; p3D: 12.5 Gy vs. 14.8 Gy vs. 15.8 Gy: p3D-plans. Heart D(max) was only marginally reduced with IMRT (3D vs. 13- vs. 17-field IMRT: 38.2 Gy vs. 36.8 Gy vs. 37.8 Gy). Simulated breathing motion caused only minor changes in the IMRT dose distribution (~0.5-1 Gy). Anisotropic modulation of IMRT improves dose delivery over 3D-RT and renders IMRT plans robust toward breathing induced organ motion, effectively preventing interplay effects. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Functional image-guided stereotactic body radiation therapy planning for patients with hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Tsegmed, Uranchimeg [Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima (Japan); Kimura, Tomoki, E-mail: tkkimura@hiroshima-u.ac.jp [Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima (Japan); Nakashima, Takeo [Division of Radiation Therapy, Hiroshima University Hospital, Hiroshima (Japan); Nakamura, Yuko; Higaki, Toru [Department of Diagnostic Radiology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima (Japan); Imano, Nobuki; Doi, Yoshiko; Kenjo, Masahiro; Ozawa, Shuichi; Murakami, Yuji [Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima (Japan); Awai, Kazuo [Department of Diagnostic Radiology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima (Japan); Nagata, Yasushi [Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima (Japan)

    2017-07-01

    The aim of the current planning study is to evaluate the ability of gadoxetate disodium-enhanced magnetic resonance imaging (EOB-MRI)–guided stereotactic body radiation therapy (SBRT) planning by using intensity-modulated radiation therapy (IMRT) techniques in sparing the functional liver tissues during SBRT for hepatocellular carcinoma. In this study, 20 patients with hepatocellular carcinoma were enrolled. Functional liver tissues were defined according to quantitative liver-spleen contrast ratios ≥ 1.5 on a hepatobiliary phase scan. Functional images were fused with the planning computed tomography (CT) images; the following 2 SBRT plans were designed using a “step-and-shoot” static IMRT technique for each patient: (1) an anatomical SBRT plan optimization based on the total liver; and (2) a functional SBRT plan based on the functional liver. The total prescribed dose was 48 gray (Gy) in 4 fractions. Dosimetric parameters, including dose to 95% of the planning target volume (PTV D{sub 95%}), percentages of total and functional liver volumes, which received doses from 5 to 30 Gy (V5 to V30 and fV5 to fV30), and mean doses to total and functional liver (MLD and fMLD, respectively) of the 2 plans were compared. Compared with anatomical plans, functional image-guided SBRT plans reduced MLD (mean: plan A, 5.5 Gy; and plan F, 5.1 Gy; p < 0.0001) and fMLD (mean: plan A, 5.4 Gy; and plan F, 4.9 Gy; p < 0.0001), as well as V5 to V30 and fV5 to fV30. No differences were noted in PTV coverage and nonhepatic organs at risk (OARs) doses. In conclusion, EOB-MRI–guided SBRT planning using the IMRT technique may preserve functional liver tissues in patients with hepatocellular carcinoma (HCC).

  9. Dosimetric comparison of 3DCRT versus IMRT in whole breast irradiation of early stage breast cancer

    Directory of Open Access Journals (Sweden)

    Mudasir Ashraf

    2014-08-01

    Full Text Available Purpose: The counseling regarding the treatment option is an important objective in the management of early stages breast cancer. In this study, we attempt to compare and analyze the dosimetric aspects of 3DRT over IMRT in the whole breast radiotherapy.Methods and Materials:  Both right and left sided computed tomography simulations of 14 women with early stage breast cancer were used for our retrospective study to compare the 3DCRT and IMRT. The dose prescribed was 50 Gy in 25 fractions to the whole breast PTV. The PTV was defined by adding unequal margins to the directional safety margin status of each lumpectomy cavity (i.e., medial, lateral, superior, inferior and deep margins measured from the tumor front after the examination of the surgical specimen: 2, 1.5, and 1 cm for resection margins < 1 cm, 1-2 cm, and > 2cm, respectively. And than modified so that it was no longer closer than 3mm to the skin surface and was no deep than the lung –chest interface. The prescribed dose delivered in 5 fractions per week schedule. Treatment plans were compared for target minimum dose, maximum dose, mean dose, conformity index, heterogeneity index and doses to organs at risk were compared and analysed.Results: The target coverage was achieved with 90% prescription to the 95% of the PTV. Conformity to the PTV was significantly higher with 3DCRT technique than IMRT. 3DCRT technique seems better in sparing critical organs parameters like lung V20 and Mean, heart, V25, Maximum, both lungs V20, Mean and Dose to the Normal Healthy tissue.Conclusion: We conclude from our study that treatment technique selection for whole Breast irradiation is an important factor in sparing the adjacent normal structures and in determining the associated risk. 3DCRT produces better conformity and heterogeneity indices of the target volume, also reduces dose to OARs the 3DCRT reduces the risk of radiation induced heart diseases

  10. Interobserver delineation variation in lung tumour stereotacticbody radiotherapy

    DEFF Research Database (Denmark)

    Persson, G. F.; Nygaard, D. E.; Hollensen, Christian

    2012-01-01

    the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours using a cross-sectional study design. Methods 22 consecutive patients with 26 tumours were included. Positron emission tomography/CT scans were acquired for planning of SBRT. Three oncologists and three......-sectional analysis of delineation variation for peripheral lung tumours referred for SBRT, establishing the evidence that interobserver variation is very small for these tumours....

  11. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC: A direct comparison of PET-based treatment planning.

    Science.gov (United States)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Rübe, Christian

    2016-02-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels.

  12. Intensity-modulated radiotherapy (IMRT) for carcinoma of the maxillary sinus: A comparison of IMRT planning systems

    International Nuclear Information System (INIS)

    Ahmed, Raef S.; Ove, Roger; Duan, Jun; Popple, Richard; Cobb, Glenn

    2006-01-01

    The treatment of maxillary sinus carcinoma with forward planning can be technically difficult when the neck also requires radiotherapy. This difficulty arises because of the need to spare the contralateral face while treating the bilateral neck. There is considerable potential for error in clinical setup and treatment delivery. We evaluated intensity-modulated radiotherapy (IMRT) as an improvement on forward planning, and compared several inverse planning IMRT platforms. A composite dose-volume histogram (DVH) was generated from a complex forward planned case. We compared the results with those generated by sliding window fixed field dynamic multileaf collimator (MLC) IMRT, using sets of coplanar beams. All setups included an anterior posterior (AP) beam, and 3-, 5-, 7-, and 9-field configurations were evaluated. The dose prescription and objective function priorities were invariant. We also evaluated 2 commercial tomotherapy IMRT delivery platforms. DVH results from all of the IMRT approaches compared favorably with the forward plan. Results for the various inverse planning approaches varied considerably across platforms, despite an attempt to prescribe the therapy similarly. The improvement seen with the addition of beams in the fixed beam sliding window case was modest. IMRT is an effective means of delivering radiotherapy reliably in the complex setting of maxillary sinus carcinoma with neck irradiation. Differences in objective function definition and optimization algorithms can lead to unexpected differences in the final dose distribution, and our evaluation suggests that these factors are more significant than the beam arrangement or number of beams

  13. The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer

    International Nuclear Information System (INIS)

    Wu, Q. Jackie; Thongphiew, Danthai; Wang Zhiheng; Chankong, Vira; Yin Fangfang

    2008-01-01

    Stereotactic body radiation therapy (SBRT), which delivers a much higher fractional dose than conventional treatment in only a few fractions, is an effective treatment for liver metastases. For patients who are treated under free-breathing conditions, however, respiration-induced tumor motion in the liver is a concern. Limited clinical information is available related to the impact of tumor motion and treatment technique on the dosimetric consequences. This study evaluated the dosimetric deviations between planned and delivered SBRT dose in the presence of tumor motion for three delivery techniques: three-dimensional conformal static beams (3DCRT), dynamic conformal arc (DARC), and intensity-modulated radiation therapy (IMRT). Five cases treated with SBRT for liver metastases were included in the study, with tumor motions ranging from 0.5 to 1.75 cm. For each case, three different treatment plans were developed using 3DCRT, DARC, and IMRT. The gantry/multileaf collimator (MLC) motion in the DARC plans and the MLC motion in the IMRT plans were synchronized to the patient's respiratory motion. Retrospectively sorted four-dimensional computed tomography image sets were used to determine patient-organ motion and to calculate the dose delivered during each respiratory phase. Deformable registration, using thin-plate-spline models, was performed to encode the tumor motion and deformation and to register the dose-per-phase to the reference phase images. The different dose distributions resulting from the different delivery techniques and motion ranges were compared to assess the effect of organ motion on dose delivery. Voxel dose variations occurred mostly in the high gradient regions, typically between the target volume and normal tissues, with a maximum variation up to 20%. The greatest CTV variation of all the plans was seen in the IMRT technique with the largest motion range (D99: -8.9%, D95: -8.3%, and D90: -6.3%). The greatest variation for all 3DCRT plans was less

  14. Comparative Analysis of Local Control Prediction Using Different Biophysical Models for Non-Small Cell Lung Cancer Patients Undergoing Stereotactic Body Radiotherapy

    Directory of Open Access Journals (Sweden)

    Bao-Tian Huang

    2017-01-01

    Full Text Available Purpose. The consistency for predicting local control (LC data using biophysical models for stereotactic body radiotherapy (SBRT treatment of lung cancer is unclear. This study aims to compare the results calculated from different models using the treatment planning data. Materials and Methods. Treatment plans were designed for 17 patients diagnosed with primary non-small cell lung cancer (NSCLC using 5 different fraction schemes. The Martel model, Ohri model, and the Tai model were used to predict the 2-year LC value. The Gucken model, Santiago model, and the Tai model were employed to estimate the 3-year LC data. Results. We found that the employed models resulted in completely different LC prediction except for the Gucken and the Santiago models which exhibited quite similar 3-year LC data. The predicted 2-year and 3-year LC values in different models were not only associated with the dose normalization but also associated with the employed fraction schemes. The greatest difference predicted by different models was up to 15.0%. Conclusions. Our results show that different biophysical models influence the LC prediction and the difference is not only correlated to the dose normalization but also correlated to the employed fraction schemes.

  15. Pretreatment Modified Glasgow Prognostic Score Predicts Clinical Outcomes After Stereotactic Body Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kishi, Takahiro; Matsuo, Yukinori, E-mail: ymatsuo@kuhp.kyoto-u.ac.jp; Ueki, Nami; Iizuka, Yusuke; Nakamura, Akira; Sakanaka, Katsuyuki; Mizowaki, Takashi; Hiraoka, Masahiro

    2015-07-01

    Purpose: This study aimed to evaluate the prognostic significance of the modified Glasgow Prognostic Score (mGPS) in patients with non-small cell lung cancer (NSCLC) who received stereotactic body radiation therapy (SBRT). Methods and Materials: Data from 165 patients who underwent SBRT for stage I NSCLC with histologic confirmation from January 1999 to September 2010 were collected retrospectively. Factors, including age, performance status, histology, Charlson comorbidity index, mGPS, and recursive partitioning analysis (RPA) class based on sex and T stage, were evaluated with regard to overall survival (OS) using the Cox proportional hazards model. The impact of the mGPS on cause of death and failure patterns was also analyzed. Results: The 3-year OS was 57.9%, with a median follow-up time of 3.5 years. A higher mGPS correlated significantly with poor OS (P<.001). The 3-year OS of lower mGPS patients was 66.4%, whereas that of higher mGPS patients was 44.5%. On multivariate analysis, mGPS and RPA class were significant factors for OS. A higher mGPS correlated significantly with lung cancer death (P=.019) and distant metastasis (P=.013). Conclusions: The mGPS was a significant predictor of clinical outcomes for SBRT in NSCLC patients.

  16. Response assessment of stereotactic body radiation therapy using dynamic contrast-enhanced integrated MR-PET in non-small cell lung cancer patients.

    Science.gov (United States)

    Huang, Yu-Sen; Chen, Jenny Ling-Yu; Hsu, Feng-Ming; Huang, Jei-Yie; Ko, Wei-Chun; Chen, Yi-Chang; Jaw, Fu-Shan; Yen, Ruoh-Fang; Chang, Yeun-Chung

    2018-01-01

    To evaluate the response in patients undergoing SBRT using dynamic contrast-enhanced (DCE) integrated magnetic resonance positron emission tomography (MR-PET). Stereotactic body radiation therapy (SBRT) is efficacious as a front-line local treatment for non-small cell lung cancer (NSCLC). We prospectively enrolled 19 lung tumors in 17 nonmetastatic NSCLC patients who were receiving SBRT as a primary treatment. They underwent DCE-integrated 3T MR-PET before and 6 weeks after SBRT. The following image parameters were analyzed: tumor size, standardized uptake value (SUV), apparent diffusion coefficient, K trans , k ep , v e , v p , and iAUC 60 . Chest computed tomography (CT) was performed at 3 months after SBRT. SBRT treatment led to tumor changes including significant decreases in the SUV max (-61%, P PET SUV max was correlated with the MR k ep mean (P = 0.002) and k ep SD (P 10 (P = 0.083). In patients with NSCLC who are receiving SBRT, DCE-integrated MR-PET can be used to evaluate the response after SBRT and to predict the local treatment outcome. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:191-199. © 2017 International Society for Magnetic Resonance in Medicine.

  17. IMRT with Stereotactic Body Radiotherapy Boost for High Risk Malignant Salivary Gland Malignancies : A Case Series

    Directory of Open Access Journals (Sweden)

    Sana D Karam

    2014-10-01

    Full Text Available Patients with high risk salivary gland malignancies are at increased risk of local failure. We present our institutional experience with dose escalation using hypofractionated Stereotactic Body Radiotherapy (SBRT in a subset of this rare disease. Over the course of 9 years, 10 patients presenting with skull base invasion, gross disease with one or more adverse features, or those treated with adjuvant radiation with three or more pathologic features were treated with intensity modulated radiation therapy followed by hypofractionated SBRT boost. Patients presented with variable tumor histologies, and in all but one, the tumors were classified as poorly differentiated high grade. Four patients had gross disease, 3 had gross residual disease, 3 had skull base invasion, and 2 patients had rapidly recurrent disease (≤ 6 months that had been previously treated with surgical resection. The median Stereotactic Radiosurgery boost dose was 17.5 Gy (range 10-30 Gy given in a median of 5 fractions (range 3-6 fractions for a total median cumulative dose of 81.2 Gy (range 73.2-95.6 Gy. The majority of the patients received platinum based concurrent chemotherapy with their radiation. At a median follow-up of 32 months (range 12-120 for all patients and 43 months for surviving patients (range 12-120, actuarial 3-year locoregional control, distant control, progression free survival, and overall survival were 88%, 81%, 68%, and 79%, respectively. Only one patient failed locally and two failed distantly. Serious late toxicity included graft ulceration in 1 patient and osteoradionecrosis in another patient, both of which underwent surgical reconstruction. Six patients developed fibrosis. In a subset of patients with salivary gland malignancies with skull base invasion, gross disease, or those treated adjuvantly with three or more adverse pathologic features, hypofractionated SBRT boost to Intensity Modulated Radiotherapy yields good local control rates and

  18. Computerized method for estimation of the location of a lung tumor on EPID cine images without implanted markers in stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Arimura, H; Toyofuku, F; Higashida, Y; Onizuka, Y; Terashima, H; Egashira, Y; Shioyama, Y; Nomoto, S; Honda, H; Nakamura, K; Yoshidome, S; Anai, S

    2009-01-01

    The purpose of this study was to develop a computerized method for estimation of the location of a lung tumor in cine images on an electronic portal imaging device (EPID) without implanted markers during stereotactic body radiotherapy (SBRT). Each tumor region was segmented in the first EPID cine image, i.e., reference portal image, based on a multiple-gray level thresholding technique and a region growing technique, and then the image including the tumor region was cropped as a 'tumor template' image. The tumor location was determined as the position in which the tumor template image took the maximum cross-correlation value within each consecutive portal image, which was acquired in cine mode on the EPID in treatment. EPID images with 512 x 384 pixels (pixel size: 0.56 mm) were acquired at a sampling rate of 0.5 frame s -1 by using energies of 4, 6 or 10 MV on linear accelerators. We applied our proposed method to EPID cine images (226 frames) of 12 clinical cases (ages: 51-83, mean: 72) with a non-small cell lung cancer. As a result, the average location error between tumor points obtained by our method and the manual method was 1.47 ± 0.60 mm. This preliminary study suggests that our method based on the tumor template matching technique might be feasible for tracking the location of a lung tumor without implanted markers in SBRT.

  19. Toxicity and dosimetric analysis of non-small cell lung cancer patients undergoing radiotherapy with 4DCT and image-guided intensity modulated radiotherapy: a regional centre's experience.

    Science.gov (United States)

    Livingston, Gareth C; Last, Andrew J; Shakespeare, Thomas P; Dwyer, Patrick M; Westhuyzen, Justin; McKay, Michael J; Connors, Lisa; Leader, Stephanie; Greenham, Stuart

    2016-09-01

    For patients receiving radiotherapy for locally advance non-small cell lung cancer (NSCLC), the probability of experiencing severe radiation pneumonitis (RP) appears to rise with an increase in radiation received by the lungs. Intensity modulated radiotherapy (IMRT) provides the ability to reduce planned doses to healthy organs at risk (OAR) and can potentially reduce treatment-related side effects. This study reports toxicity outcomes and provides a dosimetric comparison with three-dimensional conformal radiotherapy (3DCRT). Thirty curative NSCLC patients received radiotherapy using four-dimensional computed tomography and five-field IMRT. All were assessed for early and late toxicity using common terminology criteria for adverse events. All plans were subsequently re-planned using 3DCRT to the same standard as the clinical plans. Dosimetric parameters for lungs, oesophagus, heart and conformity were recorded for comparison between the two techniques. IMRT plans achieved improved high-dose conformity and reduced OAR doses including lung volumes irradiated to 5-20 Gy. One case each of oesophagitis and erythema (3%) were the only Grade 3 toxicities. Rates of Grade 2 oesophagitis were 40%. No cases of Grade 3 RP were recorded and Grade 2 RP rates were as low as 3%. IMRT provides a dosimetric benefit when compared to 3DCRT. While the clinical benefit appears to increase with increasing target size and increasing complexity, IMRT appears preferential to 3DCRT in the treatment of NSCLC.

  20. Hypofractionated stereotactic body radiation therapy for elderly patients with stage IIB–IV nonsmall cell lung cancer who are ineligible for or refuse other treatment modalities

    Directory of Open Access Journals (Sweden)

    Karam SD

    2014-10-01

    Full Text Available Sana D Karam,1 Zachary D Horne,2 Robert L Hong,2 Don McRae,2 David Duhamel,3 Nadim M Nasr2 1Department of Radiation Oncology, University of Colorado, Denver, CO, USA; 2Department of Radiation Oncology, 3Department of Pulmonary/Critical Care Medicine, Virginia Hospital Center, Arlington, VA, USA Objective: In elderly patients with stage IIB–IV nonsmall cell lung cancer who cannot tolerate chemotherapy, conventionally fractionated radiotherapy is the treatment of choice. We present our experience with hypofractionated stereotactic body radiation therapy (SBRT in the treatment of this patient population. Methods: Thirty-three patients with a median age of 80 years treated with fractionated SBRT were retrospectively analyzed. Most patients were smokers and had preexisting lung disease and either refused treatment or were ineligible. A median prescribed dose of 40 Gy was delivered to the prescription isodose line over a median of five treatments. The majority of patients (70% did not receive chemotherapy. Results: With a median follow-up of 9 months (range: 4–40 months, the actuarial median overall survival (OS and progression-free survival were 12 months for both. One year actuarial survival outcomes were 75%, 58%, 44%, and 48% for local control, regional control, progression-free survival, and OS, respectively. Increased volume of disease was a statistically significant predictor of worse OS. Three patients developed a grade 1 cough that peaked 3 weeks after treatment and resolved within 1 month. One patient developed grade 1 tracheal mucositis and three patients developed grade 1 pneumonitis. Both resolved 6 weeks after treatment. Three patients died within the first month of treatment, but the cause of death did not appear to be related to the treatment. Conclusion: Hypofractionated SBRT is a relatively safe and convenient treatment option for elderly patients with inoperable stage IIB–IV nonsmall cell lung cancer. However, given the small

  1. Definition of stereotactic body radiotherapy. Principles and practice for the treatment of stage I non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guckenberger, M.; Sauer, O. [University of Wuerzburg, Department of Radiation Oncology, Wuerzburg (Germany); Andratschke, N. [University of Rostock, Department of Radiotherapy and Radiation Oncology, Rostock (Germany); Alheit, H. [Distler Radiation Oncology, Bautzen/Pirna (Germany); Holy, R. [RWTH Aachen University, Department of Radiation Oncology, Aachen (Germany); Moustakis, C. [University of Muenster, Department of Radiation Oncology, Muenster (Germany); Nestle, U. [University of Freiburg, Department of Radiation Oncology, Freiburg (Germany)

    2014-01-15

    This report from the Stereotactic Radiotherapy Working Group of the German Society of Radiation Oncology (Deutschen Gesellschaft fuer Radioonkologie, DEGRO) provides a definition of stereotactic body radiotherapy (SBRT) that agrees with that of other international societies. SBRT is defined as a method of external beam radiotherapy (EBRT) that accurately delivers a high irradiation dose to an extracranial target in one or few treatment fractions. Detailed recommendations concerning the principles and practice of SBRT for early stage non-small cell lung cancer (NSCLC) are given. These cover the entire treatment process; from patient selection, staging, treatment planning and delivery to follow-up. SBRT was identified as the method of choice when compared to best supportive care (BSC), conventionally fractionated radiotherapy and radiofrequency ablation. Based on current evidence, SBRT appears to be on a par with sublobar resection and is an effective treatment option in operable patients who refuse lobectomy. (orig.) [German] Die Arbeitsgruppe ''Stereotaktische Radiotherapie'' der Deutschen Gesellschaft fuer Radioonkologie (DEGRO) erarbeitete eine Definition der Koerperstereotaxie (SBRT), die sich an vorhandene internationale Definitionen anlehnt: Die SBRT ist eine Form der perkutanen Strahlentherapie, die mit hoher Praezision eine hohe Bestrahlungsdosis in einer oder wenigen Bestrahlungsfraktionen in einem extrakraniellen Zielvolumen appliziert. Zur Praxis der SBRT beim nichtkleinzelligen Bronchialkarzinom (NSCLC) im fruehen Stadium werden detaillierte Empfehlungen gegeben, die den gesamten Ablauf der Behandlung von der Indikationsstellung, Staging, Behandlungsplanung und Applikation sowie Nachsorge umfassen. Die Koerperstereotaxie wurde als Methode der Wahl im Vergleich zu Best Supportive Care, zur konventionell fraktionierten Strahlentherapie sowie zur Radiofrequenzablation identifiziert. Die Ergebnisse nach SBRT und sublobaerer Resektion

  2. Toxicity after reirradiation of pulmonary tumours with stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Peulen, Heike; Karlsson, Kristin; Lindberg, Karin; Tullgren, Owe; Baumann, Pia; Lax, Ingmar; Lewensohn, Rolf; Wersäll, Peter

    2011-01-01

    Purpose: To assess toxicity and feasibility of reirradiation with stereotactic body radiotherapy (SBRT) after prior lung SBRT for primary lung cancer or lung metastases. Patients and materials: Twenty-nine patients reirradiated with SBRT on 32 lung lesions (11 central, 21 peripheral) were retrospectively reviewed. Median follow-up time was 12 months (range 1–97). The primary endpoint was toxicity, secondary endpoints were local control and overall survival time. Toxicity was scored according to the NCI-CTCAE version 3. Results: Grade 3–4 toxicity was scored 14 times in eight patients. Three patients died because of massive bleeding (grade 5). Larger clinical target volumes (CTV) and central tumour localization were associated with more severe toxicity. There was no correlation between mean lung dose (MLD) and lung toxicity. Local control at 5 months after reirradiation was 52%, as assessed by CT-scan (n = 12) or X-thorax (n = 3). A larger CTV was associated with poorer local control. Kaplan–Meier estimated 1- and 2-year survival rates were 59% and 43%, respectively. Conclusions: Reirradiation with SBRT is feasible although increased risk of toxicity was reported in centrally located tumours. Further research is warranted for more accurate selection of patients suitable for reirradiation with SBRT.

  3. Stereotactic hypofractionated radiotherapy in stage I (T1-2 N0 M0) non-small-cell lung cancer (NSCLC)

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Frank B.; Geinitz, Hans; Schill, Sabine; Thamm, Reinhard; Nieder, Carsten; Schratzenstaller, Ulrich; Molls, Michael [Technical Univ., Klinikum rechts der Isar, Munich (Germany). Dept. of Radiation Oncology

    2006-09-15

    Stereotactic Radiotherapy has the potential to produce high local control rates with low risk of severe lung toxicity. From December 2000 to January 2006, 68 inoperable patients (median age 76 years) with stage I NSCLC received definitive hSRT. A mean total dose of 37.5 Gy (24-40 Gy; 60%-isodose) in 3-5 fractions was applied. Immobilisation was carried out by means of a vacuum couch and low pressure foil (Medical Intelligence, Schwab Muenchen, Germany). Staging procedures were thoracic and abdominal CT-scan, FDG-PET and CT or MRI of the brain in all patients. Clinical target volume was the tumor as seen in lung windowing of CT and in FDG-PET. Organ movements (6-22 mm) and patient positioning in the couch (3-12 mm) were added as safety margin for the definition of the planning target volume (PTV), that was enclosed by the 60%-isodose. We observed four (6%) local tumor recurrences, resulting in an actuarial local tumor control rate of 96%, 88% and 88% after 1, 2 and 3 year follow-up. Nineteen patients died, with eight patients due to cancer (12%), two to local tumor progression alone. Cancer-specific survival is 96%, 82% and 73% at 1, 2 and 3 years. Eleven patients died from comorbidities, making a 53% overall 3-year survival. Fifty five percent of the patients were affected by mild acute and subacute side effects, with only 3% experiencing pneumonitis III. Late effects were pneumonitis III in 1%, rib fractures in 3%, and benign pleural effusion in 2 patients. Hypofractionated SRT is safe even in elderly patients with stage I NSCLC and significantly reduced lung capacity. It leads to high local control rates and should be offered to patients not amenable for curative resection.

  4. Developing and evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose

    Directory of Open Access Journals (Sweden)

    Hurkmans Coen W

    2008-07-01

    Full Text Available Abstract Purpose To investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs. Materials and methods For 26 patients with stage-I NSCLC treatment plans were optimized with unit density (UD, an equivalent pathlength algorithm (EPL, and a collapsed-cone (CC algorithm, prescribing 60 Gy to the PTV. After optimization the first two plans were recalculated with the more accurate CC algorithm. Dose parameters were compared for the three different optimized plans. Dose to the target and OARs was evaluated for the recalculated plans and compared with the planned values. Results For the CC algorithm dose constraints for the ratio of the 50% isodose volume and the PTV, and the V20 Gy are harder to fulfill. After recalculation of the UD and EPL plans large variations in the dose to the PTV were observed. For the unit density plans, the dose to the PTV varied from 42.1 to 63.4 Gy for individual patients. The EPL plans all overestimated the PTV dose (average 48.0 Gy. For the lungs, the recalculated V20 Gy was highly correlated to the planned value, and was 12% higher for the UD plans (R2 = 0.99, and 15% lower for the EPL plans (R2 = 0.96. Conclusion Inhomogeneity corrections have a large influence on the dose delivered to the PTV and OARs for SBRT of lung tumors. A simple rescaling of the dose to the PTV is not possible, implicating that accurate dose calculations are necessary for these treatment plans in order to prevent large discrepancies between planned and actually delivered doses to individual patients.

  5. Evaluations of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT, and VMAT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, Jalil ur, E-mail: jalil_khanphy@yahoo.com [Department of Physics, The Islamia University of Bahawalpur, Bahawalpur (Pakistan); Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX (United States); Tailor, Ramesh C. [Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX (United States); Isa, Muhammad [Department of Physics, The Islamia University of Bahawalpur, Bahawalpur (Pakistan); Princess Margaret Cancer Center, University Health Network, Toronto, Ontario (Canada); Afzal, Muhammad [Department of Physics, The Islamia University of Bahawalpur, Bahawalpur (Pakistan); Chow, James [Princess Margaret Cancer Center, University Health Network, Toronto, Ontario (Canada); Ibbott, Geoffrey S. [Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-04-01

    This study evaluated the secondary cancer risk from volumetric-modulated arc therapy (VMAT) for spine radiotherapy compared with intensity-modulated radiotherapy (IMRT) and 3-dimensional conformal radiotherapy (3DCRT). Computed tomography images of an Radiological Physics Center spine anthropomorphic phantom were exported to a treatment planning system (Pinnacle{sup 3}, version 9.4). Radiation treatment plans for spine were prepared using VMAT (dual-arc), 7-field IMRT (beam angles: 110°, 130°, 150°, 180°, 210°, 230°, and 250°), and 4-field 3DCRT technique. The mean and maximum doses, dose-volume histograms, and volumes receiving more than 2 and 4 Gy to organs at risk (OARs) were calculated and compared. The lifetime risk for secondary cancers was estimated according to the National Cancer Registry Programme Report 116. VMAT delivered the lowest maximum dose to the esophagus (4.03 Gy), bone (8.11 Gy), heart (2.11 Gy), spinal cord (6.45 Gy), and whole lung (5.66 Gy) as compared with other techniques (IMRT and 3DCRT). The volumes of OAR (esophagus) receiving more than 4 Gy were 0% for VMAT, 27.06% for IMRT, and up to 32.35% for 3DCRT. The estimated risk for secondary cancer in the respective OAR is considerably lower in VMAT compared with other techniques. The results of maximum doses and volumes of OARs suggest that the risk of secondary cancer induction for the spine in VMAT is lower than IMRT and 3DCRT, whereas VMAT has the best target coverage compared with the other techniques.

  6. Can All Centers Plan Intensity-Modulated Radiotherapy (IMRT) Effectively? An External Audit of Dosimetric Comparisons Between Three-Dimensional Conformal Radiotherapy and IMRT for Adjuvant Chemoradiation for Gastric Cancer

    International Nuclear Information System (INIS)

    Chung, Hans T.; Lee, Brian; Park, Eileen; Lu, Jiade J.; Xia Ping

    2008-01-01

    Purpose: To compare dosimetric endpoints between three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) at our center with limited IMRT experience, and to perform an external audit of the IMRT plans. Methods and Materials: Ten patients, who received adjuvant chemoradiation for gastric cancer, formed the study cohort. For standardization, the planning target volume (PTV) and organs at risk were recontoured with the assistance of a study protocol radiologic atlas. The cohort was replanned with CMS Xio to generate coplanar 3D-CRT and IMRT plans. All 10 datasets, including volumes but without the plans (i.e., blinded), were transmitted to an experienced center where IMRT plans were designed using Nomos Corvus (IMRT-C) and ADAC Pinnacle (IMRT-P). All IMRT plans were normalized to D95% receiving 45 Gy. Results: Intensity-modulated radiotherapy yielded higher PTV V45 (volume that receives ≥45 Gy) (p < 0.001) than 3D-CRT. No difference in V20 was seen in the right (p = 0.9) and left (p 0.3) kidneys, but the liver mean dose (p < 0.001) was superior with IMRT. For the external audit, IMRT-C (p = 0.002) and IMRT-P (p < 0.001) achieved significantly lower left kidney V20 than IMRT, and IMRT-P (p < 0.001) achieved lower right kidney V20 than IMRT. The IMRT-C (p = 0.003) but not IMRT-P (p = 0.6) had lower liver mean doses than IMRT. Conclusions: At our institution with early IMRT experience, IMRT improved PTV dose coverage and liver doses but not kidney doses. An external audit of IMRT plans showed that an experienced center can yield superior IMRT plans

  7. Exclusive image guided IMRT vs. radical prostatectomy followed by postoperative IMRT for localized prostate cancer: a matched-pair analysis based on risk-groups

    International Nuclear Information System (INIS)

    Azelie, Caroline; Créhange, Gilles; Gauthier, Mélanie; Mirjolet, Céline; Cormier, Luc; Martin, Etienne; Peignaux-Casasnovas, Karine; Truc, Gilles; Chamois, Jérôme; Maingon, Philippe

    2012-01-01

    To investigate whether patients treated for a localized prostate cancer (PCa) require a radical prostatectomy followed by postoperative radiotherapy or exclusive radiotherapy, in the modern era of image guided IMRT. 178 patients with PCa were referred for daily exclusive image guided IMRT (IG-IMRT) using an on-line 3D ultra-sound based system and 69 patients were referred for postoperative IMRT without image guidance after radical prostatectomy (RP + IMRT). Patients were matched in a 1:1 ratio according to their baseline risk group before any treatment. Late toxicity was scored using the CTV v3.0 scale. Biochemical failure was defined as a postoperative PSA ≤ 0.1 ng/mL followed by 1 consecutive rising PSA for the postoperative group of patients and by the Phoenix definition (nadir + 2 ng/mL) for the group of patients treated with exclusive radiotherapy. A total of 98 patients were matched (49:49). From the start of any treatment, the median follow-up was 56.6 months (CI 95% = [49.6-61.2], range [18.2-115.1]). No patient had late gastrointestinal grade ≥ 2 toxicity in the IG-IMRT group vs. 4% in the RP + IMRT group. Forty two percent of the patients in both groups had late grade ≥ 2 genitourinary toxicity. The 5-year FFF rates in the IG-IMRT group and in the RP + IMRT groups were 93.1% [80.0-97.8] and 76.5% [58.3-87.5], respectively (p = 0.031). Patients with a localized PCa treated with IG-IMRT had better oncological outcome than patients treated with RP + IMRT. Further improvements in postoperative IMRT using image guidance and dose escalation are urgently needed

  8. Quality of life during 5 years after stereotactic radiotherapy in stage I non-small cell lung cancer

    International Nuclear Information System (INIS)

    Ubels, Rutger J; Mokhles, Sahar; Andrinopoulou, Eleni R; Braat, Cornelia; Voort van Zyp, Noëlle C van der; Aluwini, Shafak; Aerts, Joachim G J V; Nuyttens, Joost J

    2015-01-01

    To determine the long-term impact of stereotactic radiotherapy (SRT) on the quality of life (QoL) of inoperable patients with early-stage non-small cell lung cancer (NSCLC). From January 2006 to February 2008, 39 patients with pathologically confirmed T1-2N0M0 NSCLC were treated with SRT. QoL, overall survival and local tumor control were assessed. The European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ)-C30 and the lung cancer-specific questionnaire QLQ-LC13 were used to investigate changes in QoL. Assessments were done before treatment, at 3 weeks, every 2–3 months during the first two years, and then every 6 months until 5 years after the treatment or death or progressive disease. The median follow up was 38 months. During the 5 years after treatment with SRT for stage I NSCLC, the level of QoL was maintained: There was a slow decline (slope: −0.015) of the global health status over the 5 years (p < 0.0001). The physical functioning and the role functioning improved slowly (slope: 0.006 and 0.004, resp.) over the years and this was also significant (p < 0.0001). The emotional functioning (EF) improved significantly at 1 year compared to the baseline. Two years after the treatment dyspnea slowly increased (slope: 0.005, p = 0.006). The actuarial overall survival was 62% at 2 years and 31% at 5-years. QoL was maintained 5 years after SRT for stage I NSCLC and EF improved significantly. Dyspnea slowly increased 2 years after the treatment

  9. Chest Wall Toxicity After Stereotactic Body Radiotherapy for Malignant Lesions of the Lung and Liver

    International Nuclear Information System (INIS)

    Andolino, David L.; Forquer, Jeffrey A.; Henderson, Mark A.; Barriger, Robert B.; Shapiro, Ronald H.; Brabham, Jeffrey G.; Johnstone, Peter A.S.; Cardenes, Higinia R.; Fakiris, Achilles J.

    2011-01-01

    Purpose: To quantify the frequency of rib fracture and chest wall (CW) pain and identify the dose-volume parameters that predict CW toxicity after stereotactic body radiotherapy (SBRT). Methods and Materials: The records of patients treated with SBRT between 2000 and 2008 were reviewed, and toxicity was scored according to Common Terminology Criteria for Adverse Events v3.0 for pain and rib fracture. Dosimetric data for CW and rib were analyzed and related to the frequency of toxicity. The risks of CW toxicity were then further characterized according to the median effective concentration (EC 50 ) dose-response model. Results: A total of 347 lesions were treated with a median follow-up of 19 months. Frequency of Grade I and higher CW pain and/or fracture for CW vs. non-CW lesions was 21% vs. 4%, respectively (p 2 > 0.9). According to the EC 50 model, 5 cc and 15 cc of CW receiving 40 Gy predict a 10% and 30% risk of CW toxicity, respectively. Conclusion: Adequate tumor coverage remains the primary objective when treating lung or liver lesions with SBRT. To minimize toxicity when treating lesions in close proximity to the CW, Dmax of the CW and/or ribs should remain <50 Gy, and <5 cc of CW should receive ≥40 Gy.

  10. SU-E-T-630: Predictive Modeling of Mortality, Tumor Control, and Normal Tissue Complications After Stereotactic Body Radiotherapy for Stage I Non-Small Cell Lung Cancer

    International Nuclear Information System (INIS)

    Lindsay, WD; Berlind, CG; Gee, JC; Simone, CB

    2015-01-01

    Purpose: While rates of local control have been well characterized after stereotactic body radiotherapy (SBRT) for stage I non-small cell lung cancer (NSCLC), less data are available characterizing survival and normal tissue toxicities, and no validated models exist assessing these parameters after SBRT. We evaluate the reliability of various machine learning techniques when applied to radiation oncology datasets to create predictive models of mortality, tumor control, and normal tissue complications. Methods: A dataset of 204 consecutive patients with stage I non-small cell lung cancer (NSCLC) treated with stereotactic body radiotherapy (SBRT) at the University of Pennsylvania between 2009 and 2013 was used to create predictive models of tumor control, normal tissue complications, and mortality in this IRB-approved study. Nearly 200 data fields of detailed patient- and tumor-specific information, radiotherapy dosimetric measurements, and clinical outcomes data were collected. Predictive models were created for local tumor control, 1- and 3-year overall survival, and nodal failure using 60% of the data (leaving the remainder as a test set). After applying feature selection and dimensionality reduction, nonlinear support vector classification was applied to the resulting features. Models were evaluated for accuracy and area under ROC curve on the 81-patient test set. Results: Models for common events in the dataset (such as mortality at one year) had the highest predictive power (AUC = .67, p < 0.05). For rare occurrences such as radiation pneumonitis and local failure (each occurring in less than 10% of patients), too few events were present to create reliable models. Conclusion: Although this study demonstrates the validity of predictive analytics using information extracted from patient medical records and can most reliably predict for survival after SBRT, larger sample sizes are needed to develop predictive models for normal tissue toxicities and more advanced

  11. SU-E-T-630: Predictive Modeling of Mortality, Tumor Control, and Normal Tissue Complications After Stereotactic Body Radiotherapy for Stage I Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lindsay, WD [University of Pennsylvania, Philadelphia, PA (United States); Oncora Medical, LLC, Philadelphia, PA (United States); Berlind, CG [Georgia Institute of Technology, Atlanta, GA (Georgia); Oncora Medical, LLC, Philadelphia, PA (United States); Gee, JC; Simone, CB [University of Pennsylvania, Philadelphia, PA (United States)

    2015-06-15

    Purpose: While rates of local control have been well characterized after stereotactic body radiotherapy (SBRT) for stage I non-small cell lung cancer (NSCLC), less data are available characterizing survival and normal tissue toxicities, and no validated models exist assessing these parameters after SBRT. We evaluate the reliability of various machine learning techniques when applied to radiation oncology datasets to create predictive models of mortality, tumor control, and normal tissue complications. Methods: A dataset of 204 consecutive patients with stage I non-small cell lung cancer (NSCLC) treated with stereotactic body radiotherapy (SBRT) at the University of Pennsylvania between 2009 and 2013 was used to create predictive models of tumor control, normal tissue complications, and mortality in this IRB-approved study. Nearly 200 data fields of detailed patient- and tumor-specific information, radiotherapy dosimetric measurements, and clinical outcomes data were collected. Predictive models were created for local tumor control, 1- and 3-year overall survival, and nodal failure using 60% of the data (leaving the remainder as a test set). After applying feature selection and dimensionality reduction, nonlinear support vector classification was applied to the resulting features. Models were evaluated for accuracy and area under ROC curve on the 81-patient test set. Results: Models for common events in the dataset (such as mortality at one year) had the highest predictive power (AUC = .67, p < 0.05). For rare occurrences such as radiation pneumonitis and local failure (each occurring in less than 10% of patients), too few events were present to create reliable models. Conclusion: Although this study demonstrates the validity of predictive analytics using information extracted from patient medical records and can most reliably predict for survival after SBRT, larger sample sizes are needed to develop predictive models for normal tissue toxicities and more advanced

  12. Poster – 12: Radiological assessment of the secondary barrier shielding for IMRT treatments delivered through patient inhomogeneities

    Energy Technology Data Exchange (ETDEWEB)

    Haseeb, Syed Abdul; Ahmad, Syed Bilal; Mirza, Sikander Majid [Pakistan Institute of Engineering and Applied Science, Nilore, Islamabad, Pakistan, Sunnybrook Health Sciences Center, Toronto, ON, Canada & Pakistan Institute of Engineering and Applied Science, Nilore, Islamabad, Pakistan, Pakistan Institute of Engineering and Applied Science, Nilore, Islamabad (Pakistan)

    2016-08-15

    Purpose: To assess the impact of radiation treatment delivery through patient inhomogeneities on the secondary barrier shielding requirements in IMRT treatments using Monte Carlo Simulations. Materials and Methods: Scatter factors were calculated at a distance of 1m from the center of a virtual phantom in Geant4.10.01. Phantom (30×30×30 cm{sup 3}) was inserted with lung (30×30×8 cm{sup 3}), stainless steel (5×5×5 cm{sup 3}) and aluminum (5×5×5 cm{sup 3}) to represent the inhomogeneities. Scatter factor was defined according to the NCRP-151 recommendations and was calculated for angles of 3° to 120° with respect to the beam’s central axis. A virtual radiation source, with energy sampled from a histogram representing 6 MV FFF beam, was used for irradiation with a field size of 15×15 cm{sup 2} and SSD of 100 cm. Results: Irradiation through the inhomogeneity affects the patient scattered dose. For high Z material inhomogeneities the scattered dose is reduced due to significant attenuation of the primary radiation. On the other hand if the inhomogeneity is a low Z material such as lung the scattered dose is higher by a maximum of 26%. The average increase in scatter factors for the lung phantom was 17% for angles between 3° and 63° compared to the homogeneous water phantom. Conclusions: In IMRT type treatments delivered through low density patient inhomogeneities (lung) the scattered dose increases significantly. Considering a large proportion of patients receiving radiation therapy for lung cancers the increase in the scattered dose should be incorporated in the shielding calculations for the secondary barriers.

  13. IMRT for Image-Guided Single Vocal Cord Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Osman, Sarah O.S., E-mail: s.osman@erasmusmc.nl [Department of Radiation Oncology, Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Astreinidou, Eleftheria; Boer, Hans C.J. de; Keskin-Cambay, Fatma; Breedveld, Sebastiaan; Voet, Peter; Al-Mamgani, Abrahim; Heijmen, Ben J.M.; Levendag, Peter C. [Department of Radiation Oncology, Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands)

    2012-02-01

    Purpose: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. Methods and Materials: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. Results: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose {+-} standard deviation to the planning target volume was 67 {+-} 1 Gy. The contralateral vocal cord dose was reduced from 66 {+-} 1 Gy in the conventional plans to 39 {+-} 8 Gy and 36 {+-} 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. Conclusions: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates.

  14. IMRT for Image-Guided Single Vocal Cord Irradiation

    International Nuclear Information System (INIS)

    Osman, Sarah O.S.; Astreinidou, Eleftheria; Boer, Hans C.J. de; Keskin-Cambay, Fatma; Breedveld, Sebastiaan; Voet, Peter; Al-Mamgani, Abrahim; Heijmen, Ben J.M.; Levendag, Peter C.

    2012-01-01

    Purpose: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. Methods and Materials: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. Results: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose ± standard deviation to the planning target volume was 67 ± 1 Gy. The contralateral vocal cord dose was reduced from 66 ± 1 Gy in the conventional plans to 39 ± 8 Gy and 36 ± 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. Conclusions: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates.

  15. Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer

    International Nuclear Information System (INIS)

    Han Tao; Followill, David; Repchak, Roman; Molineu, Andrea; Howell, Rebecca; Salehpour, Mohammad; Mikell, Justin; Mourtada, Firas

    2013-01-01

    Purpose: The novel deterministic radiation transport algorithm, Acuros XB (AXB), has shown great potential for accurate heterogeneous dose calculation. However, the clinical impact between AXB and other currently used algorithms still needs to be elucidated for translation between these algorithms. The purpose of this study was to investigate the impact of AXB for heterogeneous dose calculation in lung cancer for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Methods: The thorax phantom from the Radiological Physics Center (RPC) was used for this study. IMRT and VMAT plans were created for the phantom in the Eclipse 11.0 treatment planning system. Each plan was delivered to the phantom three times using a Varian Clinac iX linear accelerator to ensure reproducibility. Thermoluminescent dosimeters (TLDs) and Gafchromic EBT2 film were placed inside the phantom to measure delivered doses. The measurements were compared with dose calculations from AXB 11.0.21 and the anisotropic analytical algorithm (AAA) 11.0.21. Two dose reporting modes of AXB, dose-to-medium in medium (D m,m ) and dose-to-water in medium (D w,m ), were studied. Point doses, dose profiles, and gamma analysis were used to quantify the agreement between measurements and calculations from both AXB and AAA. The computation times for AAA and AXB were also evaluated. Results: For the RPC lung phantom, AAA and AXB dose predictions were found in good agreement to TLD and film measurements for both IMRT and VMAT plans. TLD dose predictions were within 0.4%–4.4% to AXB doses (both D m,m and D w,m ); and within 2.5%–6.4% to AAA doses, respectively. For the film comparisons, the gamma indexes (±3%/3 mm criteria) were 94%, 97%, and 98% for AAA, AXB Dm,m , and AXB Dw,m , respectively. The differences between AXB and AAA in dose–volume histogram mean doses were within 2% in the planning target volume, lung, heart, and within 5% in the spinal cord. However

  16. Study of the absorbed dose in small fields with absence of lateral electronic balance in stereotactic radiosurgery and radiotherapy with modulated intensity; Estudio de la dosis absorbida en campos pequenos con ausencia de equilibrio electronico lateral en radiocirugia estereotaxica y radioterapia con intensidad modulada

    Energy Technology Data Exchange (ETDEWEB)

    Vargas V, M. X.

    2013-07-01

    In this thesis we develop and experimental and theoretical study, using semi analytical techniques of the physical dosimetry for small and nonstandard fields for stereotactic radiosurgery (Srs) and intensity modulated radiation therapy (IMRT), with high energy photon beams from a BrainLAB system with cones at Instituto del Cancer SOLCA (Ecuador) and a Tomo Therapy Hi-Art system at Centro Oncologico de Chihuahua (Mexico). (Author)

  17. Outcomes of Stereotactic Ablative Radiotherapy in Patients With Potentially Operable Stage I Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lagerwaard, Frank J., E-mail: fj.lagerwaard@vumc.nl [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Verstegen, Naomi E.; Haasbeek, Cornelis J.A.; Slotman, Ben J. [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Paul, Marinus A. [Department of Thoracic Surgery, VU University Medical Center, Amsterdam (Netherlands); Smit, Egbert F. [Department of Pulmonary Medicine, VU University Medical Center, Amsterdam (Netherlands); Senan, Suresh [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands)

    2012-05-01

    Background: Approximately two-thirds of patients with early-stage non-small-cell lung cancer (NSCLC) in The Netherlands currently undergo surgical resection. As an increasing number of fit patients have elected to undergo stereotactic ablative radiotherapy (SABR) in recent years, we studied outcomes after SABR in patients with potentially operable stage I NSCLC. Methods and Materials: In an institutional prospective database collected since 2003, 25% of lung SABR cases (n = 177 patients) were found to be potentially operable when the following patients were excluded: those with (1) synchronous lung tumors or other malignancy, (2) prior high-dose radiotherapy/pneumonectomy, (3) chronic obstructive pulmonary disease with a severity score of 3-4 according to the Global initiative for Obstructive Lung Disease classification. (4) a performance score of {>=}3, and (5) other comorbidity precluding surgery. Study patients included 101 males and 76 females, with a median age of 76 years old, 60% of whom were staged as T1 and 40% of whom were T2. Median Charlson comorbidity score was 2 (range, 0-5). A SABR dose of 60 Gy was delivered using a risk-adapted scheme in 3, 5, or 8 fractions, depending on tumor size and location. Follow-up chest computed tomography scans were obtained at 3, 6, and 12 months and yearly thereafter. Results: Median follow-up was 31.5 months; and median overall survival (OS) was 61.5 months, with 1- and 3-year survival rates of 94.7% and 84.7%, respectively. OS rates at 3 years in patients with (n = 59) and without (n = 118) histological diagnosis did not differ significantly (96% versus 81%, respectively, p = 0.39). Post-SABR 30-day mortality was 0%, while predicted 30-day mortality for a lobectomy, derived using the Thoracoscore predictive model (Falcoz PE et al. J Thorac Cardiovasc Surg 2007;133:325-332), would have been 2.6%. Local control rates at 1 and 3 years were 98% and 93%, respectively. Regional and distant failure rates at 3 years were each

  18. A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation.

    Science.gov (United States)

    Zhao, Yanqun; Qi, Guohai; Yin, Gang; Wang, Xianliang; Wang, Pei; Li, Jian; Xiao, Mingyong; Li, Jie; Kang, Shengwei; Liao, Xiongfei

    2014-12-16

    The accuracy of dose calculation is crucial to the quality of treatment planning and, consequently, to the dose delivered to patients undergoing radiation therapy. Current general calculation algorithms such as Pencil Beam Convolution (PBC) and Collapsed Cone Convolution (CCC) have shortcomings in regard to severe inhomogeneities, particularly in those regions where charged particle equilibrium does not hold. The aim of this study was to evaluate the accuracy of the PBC and CCC algorithms in lung cancer radiotherapy using Monte Carlo (MC) technology. Four treatment plans were designed using Oncentra Masterplan TPS for each patient. Two intensity-modulated radiation therapy (IMRT) plans were developed using the PBC and CCC algorithms, and two three-dimensional conformal therapy (3DCRT) plans were developed using the PBC and CCC algorithms. The DICOM-RT files of the treatment plans were exported to the Monte Carlo system to recalculate. The dose distributions of GTV, PTV and ipsilateral lung calculated by the TPS and MC were compared. For 3DCRT and IMRT plans, the mean dose differences for GTV between the CCC and MC increased with decreasing of the GTV volume. For IMRT, the mean dose differences were found to be higher than that of 3DCRT. The CCC algorithm overestimated the GTV mean dose by approximately 3% for IMRT. For 3DCRT plans, when the volume of the GTV was greater than 100 cm(3), the mean doses calculated by CCC and MC almost have no difference. PBC shows large deviations from the MC algorithm. For the dose to the ipsilateral lung, the CCC algorithm overestimated the dose to the entire lung, and the PBC algorithm overestimated V20 but underestimated V5; the difference in V10 was not statistically significant. PBC substantially overestimates the dose to the tumour, but the CCC is similar to the MC simulation. It is recommended that the treatment plans for lung cancer be developed using an advanced dose calculation algorithm other than PBC. MC can accurately

  19. Dosimetry of parotid glands in IMRT plan of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lian Jiancheng; Yu Xinsheng; Jiang Guoliang

    2007-01-01

    Objective: To evaluate the effect of different intensity-modulated radiation therapy (IMRT) plan on the dosimetry of parotid in patients with nasopharyngeal carcinoma. Methods: Under the same constraints and objections, the IMRT plan of nasopharyngeal carcinoma with sparing unilateral parotid and the IMRT plan added plan tumor volume (PTV) margin for parotid gland was investigated. Results: Between conventional IMRT plan and the IMRT plan spared unilateral parotid, their target coverage, homogeneity index and conformal index of PTV 70 is similar. On PTV 60 , D min in the plan of sparing one parotid gland was more than that in normal IMRT plan (P 95 in the plan of sparing one parotid gland have improved (P 50%VOL and D mean of parotid gland were similar between the two plans. Between conventional IMRT plan and the IMRT plan added 2 or 3 mm margin for parotid gland, their target coverage, homogeneity index and conformal index of PTV 70 is similar. D min , D mean and D 95 of PTV 60 have decreased tendency from normal IMRT plan to 2 mm margin plan to 3 mm margin plan. D max of brainstem and spine cord have increased tendency from normal IMRT plan to 2 mm margin plan to 3 mm margin plan. Conclusions: The IMRT plan of nasopharyngeal carcinoma with sparing unilateral parotid may be adopted not to protect both two parotids, while PTV margin for parotid added as parotid move. (authors)

  20. The history of stereotactic radiosurgery and radiotherapy.

    Science.gov (United States)

    Lasak, John M; Gorecki, John P

    2009-08-01

    Stereotactic neurosurgery originated from the pioneering work of Horsley and Clarke, who developed a stereotactic apparatus to study the monkey brain in 1908. Spiegel and Wycis applied this technology to the human brain in 1947, which ultimately lead to the development of multiple stereotactic neurosurgical devices during the 1950s. It was Lars Leksell of Sweden, however, who envisioned stereotactic radiosurgery. Leksell developed the gamma knife to treat intracranial lesions in a noninvasive fashion. His work stimulated worldwide interest and created the field of stereotactic radiosurgery.

  1. Intensity modulated radiotherapy (IMRT) with concurrent chemotherapy as definitive treatment of locally advanced esophageal cancer

    International Nuclear Information System (INIS)

    Roeder, Falk; Nicolay, Nils H; Nguyen, Tam; Saleh-Ebrahimi, Ladan; Askoxylakis, Vasilis; Bostel, Tilman; Zwicker, Felix; Debus, Juergen; Timke, Carmen; Huber, Peter E

    2014-01-01

    To report our experience with increased dose intensity-modulated radiation and concurrent systemic chemotherapy as definitive treatment of locally advanced esophageal cancer. We analyzed 27 consecutive patients with histologically proven esophageal cancer, who were treated with increased-dose IMRT as part of their definitive therapy. The majority of patients had T3/4 and/or N1 disease (93%). Squamous cell carcinoma was the dominating histology (81%). IMRT was delivered in step-and-shoot technique in all patients using an integrated boost concept. The boost volume was covered with total doses of 56-60 Gy (single dose 2-2.14 Gy), while regional nodal regions received 50.4 Gy (single dose 1.8 Gy) in 28 fractions. Concurrent systemic therapy was scheduled in all patients and administered in 26 (96%). 17 patients received additional adjuvant systemic therapy. Loco-regional control, progression-free and overall survival as well as acute and late toxicities were retrospectively analyzed. In addition, quality of life was prospectively assessed according to the EORTC QLQs (QLQ-OG25, QLQ-H&N35 and QLQ-C30). Radiotherapy was completed as planned in all but one patient (96%), and 21 patients received more than 80% of the planned concurrent systemic therapy. We observed ten locoregional failures, transferring into actuarial 1-, 2- and 3-year-locoregional control rates of 77%, 65% and 48%. Seven patients developed distant metastases, mainly to the lung (71%). The actuarial 1-, 2- and 3-year-disease free survival rates were 58%, 48% and 36%, and overall survival rates were 82%, 61% and 56%. The concept was well tolerated, both in the clinical objective examination and also according to the subjective answers to the QLQ questionnaire. 14 patients (52%) suffered from at least one acute CTC grade 3/4 toxicity, mostly hematological side effects or dysphagia. Severe late toxicities were reported in 6 patients (22%), mostly esophageal strictures and ulcerations. Severe side effects to

  2. Clinical Results of Mean GTV Dose Optimized Robotic-Guided Stereotactic Body Radiation Therapy for Lung Tumors

    Directory of Open Access Journals (Sweden)

    Rene Baumann

    2018-05-01

    Full Text Available IntroductionWe retrospectively evaluated the efficacy and toxicity of gross tumor volume (GTV mean dose optimized stereotactic body radiation therapy (SBRT for primary and secondary lung tumors with and without robotic real-time motion compensation.Materials and methodsBetween 2011 and 2017, 208 patients were treated with SBRT for 111 primary lung tumors and 163 lung metastases with a median GTV of 8.2 cc (0.3–174.0 cc. Monte Carlo dose optimization was performed prioritizing GTV mean dose at the potential cost of planning target volume (PTV coverage reduction while adhering to safe normal tissue constraints. The median GTV mean biological effective dose (BED10 was 162.0 Gy10 (34.2–253.6 Gy10 and the prescribed PTV BED10 ranged 23.6–151.2 Gy10 (median, 100.8 Gy10. Motion compensation was realized through direct tracking (44.9%, fiducial tracking (4.4%, and internal target volume (ITV concepts with small (≤5 mm, 33.2% or large (>5 mm, 17.5% motion. The local control (LC, progression-free survival (PFS, overall survival (OS, and toxicity were analyzed.ResultsMedian follow-up was 14.5 months (1–72 months. The 2-year actuarial LC, PFS, and OS rates were 93.1, 43.2, and 62.4%, and the median PFS and OS were 18.0 and 39.8 months, respectively. In univariate analysis, prior local irradiation (hazard ratio (HR 0.18, confidence interval (CI 0.05–0.63, p = 0.01, GTV/PTV (HR 1.01–1.02, CI 1.01–1.04, p < 0.02, and PTV prescription, mean GTV, and maximum plan BED10 (HR 0.97–0.99, CI 0.96–0.99, p < 0.01 were predictive for LC while the tracking method was not (p = 0.97. For PFS and OS, multivariate analysis showed Karnofsky Index (p < 0.01 and tumor stage (p ≤ 0.02 to be significant factors for outcome prediction. Late radiation pneumonitis or chronic rip fractures grade 1–2 were observed in 5.3% of the patients. Grade ≥3 side effects did not occur.ConclusionRobotic SBRT is a safe and

  3. Stereotactic body radiotherapy: current strategies and future development

    Science.gov (United States)

    2016-01-01

    Stereotactic body radiotherapy (SBRT) has emerged as the standard treatment for medically inoperable early-staged non-small cell lung cancer (NSCLC). The local control rate after SBRT is over 90%. Some forms of tumour motion management and image-guided radiation delivery techniques are the prerequisites for fulfilment of its goal to deliver a high radiation dose to the tumour target without overdosing surrounding normal tissues. In this review, the current strategies of tumour motion management will be discussed, followed by an overview of various image-guided radiotherapy (RT) systems and devices available for clinical practice. Besides medically inoperable stage I NSCLC, SBRT has also been widely adopted for treatment of oligometastasis involving the lungs. Its possible applications in various other cancer illnesses are under extensive exploration. The progress of SBRT is critically technology-dependent. With advancement of technology, the ideal of personalised, effective and yet safe SBRT is already on the horizon. PMID:27606082

  4. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    International Nuclear Information System (INIS)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian

    2016-01-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [de

  5. Software for simulating IMRT protocol

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Thelma C.F.; Campos, Tarcisio P.R. de, E-mail: tcff@ufmg.b, E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear

    2009-07-01

    The Intensity Modulated Radiation Therapy - IMRT is an advanced technique to cancer treatment widely used on oncology around the world. The present paper describes the SOFT-RT software which is a tool for simulating IMRT protocol. Also, it will be present a cerebral tumor case of studied in which three irradiation windows with distinct orientation were applied. The SOFT-RT collect and export data to MCNP code. This code simulates the photon transport on the voxel model. Later, a out-module from SOFT-RT import the results and express the dose-response superimposing dose and voxel model in a tree-dimensional graphic representation. The present paper address the IMRT software and its function as well a cerebral tumor case of studied is showed. The graphic interface of the SOFT-RT illustrates the example case. (author)

  6. Software for simulating IMRT protocol

    International Nuclear Information System (INIS)

    Fonseca, Thelma C.F.; Campos, Tarcisio P.R. de

    2009-01-01

    The Intensity Modulated Radiation Therapy - IMRT is an advanced technique to cancer treatment widely used on oncology around the world. The present paper describes the SOFT-RT software which is a tool for simulating IMRT protocol. Also, it will be present a cerebral tumor case of studied in which three irradiation windows with distinct orientation were applied. The SOFT-RT collect and export data to MCNP code. This code simulates the photon transport on the voxel model. Later, a out-module from SOFT-RT import the results and express the dose-response superimposing dose and voxel model in a tree-dimensional graphic representation. The present paper address the IMRT software and its function as well a cerebral tumor case of studied is showed. The graphic interface of the SOFT-RT illustrates the example case. (author)

  7. Monte Carlo-based QA for IMRT of head and neck cancers

    Science.gov (United States)

    Tang, F.; Sham, J.; Ma, C.-M.; Li, J.-S.

    2007-06-01

    It is well-known that the presence of large air cavity in a dense medium (or patient) introduces significant electronic disequilibrium when irradiated with megavoltage X-ray field. This condition may worsen by the possible use of tiny beamlets in intensity-modulated radiation therapy (IMRT). Commercial treatment planning systems (TPSs), in particular those based on the pencil-beam method, do not provide accurate dose computation for the lungs and other cavity-laden body sites such as the head and neck. In this paper we present the use of Monte Carlo (MC) technique for dose re-calculation of IMRT of head and neck cancers. In our clinic, a turn-key software system is set up for MC calculation and comparison with TPS-calculated treatment plans as part of the quality assurance (QA) programme for IMRT delivery. A set of 10 off-the-self PCs is employed as the MC calculation engine with treatment plan parameters imported from the TPS via a graphical user interface (GUI) which also provides a platform for launching remote MC simulation and subsequent dose comparison with the TPS. The TPS-segmented intensity maps are used as input for the simulation hence skipping the time-consuming simulation of the multi-leaf collimator (MLC). The primary objective of this approach is to assess the accuracy of the TPS calculations in the presence of air cavities in the head and neck whereas the accuracy of leaf segmentation is verified by fluence measurement using a fluoroscopic camera-based imaging device. This measurement can also validate the correct transfer of intensity maps to the record and verify system. Comparisons between TPS and MC calculations of 6 MV IMRT for typical head and neck treatments review regional consistency in dose distribution except at and around the sinuses where our pencil-beam-based TPS sometimes over-predicts the dose by up to 10%, depending on the size of the cavities. In addition, dose re-buildup of up to 4% is observed at the posterior nasopharyngeal

  8. IMRT delivery verification using a spiral phantom

    International Nuclear Information System (INIS)

    Richardson, Susan L.; Tome, Wolfgang A.; Orton, Nigel P.; McNutt, Todd R.; Paliwal, Bhudatt R.

    2003-01-01

    In this paper we report on the testing and verification of a system for IMRT delivery quality assurance that uses a cylindrical solid water phantom with a spiral trajectory for radiographic film placement. This spiral film technique provides more complete dosimetric verification of the entire IMRT treatment than perpendicular film methods, since it samples a three-dimensional dose subspace rather than using measurements at only one or two depths. As an example, the complete analysis of the predicted and measured spiral films is described for an intracranial IMRT treatment case. The results of this analysis are compared to those of a single field perpendicular film technique that is typically used for IMRT QA. The comparison demonstrates that both methods result in a dosimetric error within a clinical tolerance of 5%, however the spiral phantom QA technique provides a more complete dosimetric verification while being less time consuming. To independently verify the dosimetry obtained with the spiral film, the same IMRT treatment was delivered to a similar phantom in which LiF thermoluminescent dosimeters were arranged along the spiral trajectory. The maximum difference between the predicted and measured TLD data for the 1.8 Gy fraction was 0.06 Gy for a TLD located in a high dose gradient region. This further validates the ability of the spiral phantom QA process to accurately verify delivery of an IMRT plan

  9. Comparison of three IMRT inverse planning techniques that allow for partial esophagus sparing in patients receiving thoracic radiation therapy for lung cancer

    International Nuclear Information System (INIS)

    Xiao Ying; Werner-Wasik, Maria; Michalski, D.; Houser, C.; Bednarz, G.; Curran, W.; Galvin, James

    2004-01-01

    The purpose of this study is to compare 3 intensity-modulated radiation therapy (IMRT) inverse treatment planning techniques as applied to locally-advanced lung cancer. This study evaluates whether sufficient radiotherapy (RT) dose is given for durable control of tumors while sparing a portion of the esophagus, and whether large number of segments and monitor units are required. We selected 5 cases of locally-advanced lung cancer with large central tumor, abutting the esophagus. To ensure that no more than half of the esophagus circumference at any level received the specified dose limit, it was divided into disk-like sections and dose limits were imposed on each. Two sets of dose objectives were specified for tumor and other critical structures for standard dose RT and for dose escalation RT. Plans were generated using an aperture-based inverse planning (ABIP) technique with the Cimmino algorithm for optimization. Beamlet-based inverse treatment planning was carried out with a commercial simulated annealing package (CORVUS) and with an in-house system that used the Cimmino projection algorithm (CIMM). For 3 of the 5 cases, results met all of the constraints from the 3 techniques for the 2 sets of dose objectives. The CORVUS system without delivery efficiency consideration required the most segments and monitor units. The CIMM system reduced the number while the ABIP techniques showed a further reduction, although for one of the cases, a solution was not readily obtained using the ABIP technique for dose escalation objectives

  10. Dosimetric evaluation of the feasibility of stereotactic body radiotherapy for primary lung cancer with lobe-specific selective elective nodal irradiation.

    Science.gov (United States)

    Komatsu, Tetsuya; Kunieda, Etsuo; Kitahara, Tadashi; Akiba, Takeshi; Nagao, Ryuta; Fukuzawa, Tsuyoshi

    2016-01-01

    More than 10% of all patients treated with stereotactic body radiotherapy (SBRT) for primary lung cancer develop regional lymph node recurrence. We evaluated the dosimetric feasibility of SBRT with lobe-specific selective elective nodal irradiation (ENI) on dose-volume histograms. A total of 21 patients were treated with SBRT for Stage I primary lung cancer between January 2010 and June 2012 at our institution. The extents of lobe-specific selective ENI fields were determined with reference to prior surgical reports. The ENI fields included lymph node stations (LNS) 3 + 4 + 11 for the right upper lobe tumors, LNS 7 + 11 for the right middle or lower lobe tumors, LNS 5 + 11 for the left upper lobe tumors, and LNS 7 + 11 for the left lower lobe tumors. A composite plan was generated by combining the ENI plan and the SBRT plan and recalculating for biologically equivalent doses of 2 Gy per fraction, using a linear quadratic model. The V20 of the lung, D(1cm3) of the spinal cord, D(1cm3) and D(10cm3) of the esophagus and D(10cm3) of the tracheobronchial wall were evaluated. Of the 21 patients, nine patients (43%) could not fulfill the dose constraints. In all these patients, the distance between the planning target volume (PTV) of ENI (PTVeni) and the PTV of SBRT (PTVsrt) was ≤2.0 cm. Of the three patients who developed regional metastasis, two patients had isolated lymph node failure, and the lymph node metastasis was included within the ENI field. When the distance between the PTVeni and PTVsrt is >2.0 cm, SBRT with selective ENI may therefore dosimetrically feasible. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  11. Clinical outcome and predictors of survival and pneumonitis after stereotactic ablative radiotherapy for stage I non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Chang Joe Y

    2012-09-01

    Full Text Available Abstract Background Stereotactic ablative radiotherapy (SABR can achieve excellent local control rates in early-stage non-small cell lung cancer (NSCLC and has emerged as a standard treatment option for patients who cannot undergo surgery or those with isolated recurrences. However, factors that may predict toxicity or survival are largely unknown. We sought here to identify predictors of survival and pneumonitis after SABR for NSCLC in a relatively large single-institution series. Methods Subjects were 130 patients with stage I NSCLC treated with four-dimensional computed tomography (4D CT –planned, on-board volumetric image–guided SABR to 50 Gy in 4 fractions. Disease was staged by positron emission tomography/computed tomography (PET/CT and scans were obtained again at the second follow-up after SABR. Results At a median follow-up time of 26 months, the 2-year local control rate was 98.5%. The median overall survival (OS time was 60 months, and OS rates were 93.0% at 1 year, 78.2% at 2 years, and 65.3% at 3 years. No patient experienced grade 4–5 toxicity; 15 had radiation pneumonitis (12 [9.3%] grade 2 and 3 [2.3%] grade 3. Performance status, standardized uptake value (SUVmax on staging PET/CT, tumor histology, and disease operability were associated with OS on univariate analysis, but only staging SUVmax was independently predictive on multivariate analysis (P = 0.034. Dosimetric factors were associated with radiation pneumonitis on univariate analysis, but only mean ipsilateral lung dose ≥9.14 Gy was significant on multivariate analysis (P = 0.005. Conclusions OS and radiation pneumonitis after SABR for stage I NSCLC can be predicted by staging PET SUVmax and ipsilateral mean lung dose, respectively.

  12. Colorectal Histology Is Associated With an Increased Risk of Local Failure in Lung Metastases Treated With Stereotactic Ablative Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Binkley, Michael S. [Department of Radiation Oncology and Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Trakul, Nicholas [Department of Radiation Oncology, University of Southern California Keck School of Medicine, Los Angeles, California (United States); Jacobs, Lisa Rose; Eyben, Rie von; Le, Quynh-Thu; Maxim, Peter G.; Loo, Billy W. [Department of Radiation Oncology and Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Shultz, David Benjamin, E-mail: DavidS4@Stanford.edu [Department of Radiation Oncology and Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Diehn, Maximilian, E-mail: Diehn@Stanford.edu [Department of Radiation Oncology and Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Institute for Stem Cell Biology and Regenerative Medicine, Stanford University School of Medicine, Stanford, California (United States)

    2015-08-01

    Purpose: Stereotactic ablative radiation therapy (SABR) is increasingly used to treat lung oligometastases. We set out to determine the safety and efficacy of this approach and to identify factors associated with outcomes. Methods and Materials: We conducted a retrospective study of patients treated with SABR for metastatic lung tumors at our institution from 2003 to 2014. We assessed the association between various patient and treatment factors with local failure (LF), progression, subsequent treatment, systemic treatment, and overall survival (OS), using univariate and multivariate analyses. Results: We identified 122 tumors in 77 patients meeting inclusion criteria for this study. Median follow-up was 22 months. The 12- and 24-month cumulative incidence rates of LF were 8.7% and 16.2%, respectively; the 24-month cumulative incidence rates of progression, subsequent treatment, and subsequent systemic treatment were 75.2%, 64.5%, and 35.1%, respectively. Twenty-four-month OS was 74.6%, and median OS was 36 months. Colorectal metastases had a significantly higher cumulative incidence of LF at 12 and 24 months (25.5% and 42.2%, respectively), than all other histologies (4.4% and 9.9%, respectively; P<.0004). The 24-month cumulative incidences of LF for colorectal metastases treated with a biologically effective dose at α/β = 10 (BED{sub 10}) of <100 Gy versus BED{sub 10} of ≥100 Gy were 62.5% and 16.7%, respectively (P=.08). Toxicity was minimal, with only a single grade 3 or higher event observed. Conclusions: SABR for metastatic lung tumors appears to be safe and effective with excellent local control, treatment-free intervals, and OS. An exception is metastases from colorectal cancer, which have a high LF rate consistent with a radioresistant phenotype, suggesting a potential role for dose escalation.

  13. Comparison of IMRT Treatment Plans Between Linac and Helical Tomotherapy Based on Integral Dose and Inhomogeneity Index

    International Nuclear Information System (INIS)

    Shi Chengyu; Penagaricano, Jose; Papanikolaou, Niko

    2008-01-01

    Intensity modulated radiotherapy (IMRT) is an advanced treatment technology for radiation therapy. There are several treatment planning systems (TPS) that can generate IMRT plans. These plans may show different inhomogeneity indices to the planning target volume (PTV) and integral dose to organs at risk (OAR). In this study, we compared clinical cases covering different anatomical treatment sites, including head and neck, brain, lung, prostate, pelvis, and cranio-spinal axis. Two treatment plans were developed for each case using Pinnacle 3 and helical tomotherapy (HT) TPS. The inhomogeneity index of the PTV and the non-tumor integral dose (NTID) were calculated and compared for each case. Despite the difference in the number of effective beams, in several cases, NTID did not increase from HT as compared to the step-and-shoot delivery method. Six helical tomotherapy treatment plans for different treatment sites have been analyzed and compared against corresponding step-and-shoot plans generated with the Pinnacle 3 planning system. Results show that HT may produce plans with smaller integral doses to healthy organs, and fairly homogeneous doses to the target as compared to linac-based step-and-shoot IMRT planning in special treatment site such as cranio-spinal

  14. Stereotactic Ablative Radiation Therapy for Subcentimeter Lung Tumors: Clinical, Dosimetric, and Image Guidance Considerations

    International Nuclear Information System (INIS)

    Louie, Alexander V.; Senan, Suresh; Dahele, Max; Slotman, Ben J.; Verbakel, Wilko F.A.R.

    2014-01-01

    Purpose: Use of stereotactic ablative radiation therapy (SABR) for subcentimeter lung tumors is controversial. We report our outcomes for tumors with diameter ≤1 cm and their visibility on cone beam computed tomography (CBCT) scans and retrospectively evaluate the planned dose using a deterministic dose calculation algorithm (Acuros XB [AXB]). Methods and Materials: We identified subcentimeter tumors from our institutional SABR database. Tumor size was remeasured on an artifact-free phase of the planning 4-dimensional (4D)-CT. Clinical plan doses were generated using either a pencil beam convolution or an anisotropic analytic algorithm (AAA). All AAA plans were recalculated using AXB, and differences among D95 and mean dose for internal target volume (ITV) and planning target volume (PTV) on the average intensity CT dataset, as well as for gross tumor volume (GTV) on the end respiratory phases were reported. For all AAA patients, CBCT scans acquired during each treatment fraction were evaluated for target visibility. Progression-free and overall survival rates were calculated using the Kaplan-Meier method. Results: Thirty-five patients with 37 subcentimeter tumors were eligible for analysis. For the 22 AAA plans recalculated using AXB, Mean D95 ± SD values were 2.2 ± 4.4% (ITV) and 2.5 ± 4.8% (PTV) lower using AXB; whereas mean doses were 2.9 ± 4.9% (ITV) and 3.7 ± 5.1% (PTV) lower. Calculated AXB doses were significantly lower in one patient (difference in mean ITV and PTV doses, as well as in mean ITV and PTV D95 ranged from 22%-24%). However, the end respiratory phase GTV received at least 95% of the prescription dose. Review of 92 CBCT scans from all AAA patients revealed that the tumor was visualized in 82 images, and its position could be inferred in other images. The 2-year local progression-free survival was 100%. Conclusions: Patients with subcentimeter lung tumors are good candidates for SABR, given the dosimetry, ability to localize

  15. A multi-centre dosimetry audit on advanced radiotherapy in lung as part of the Isotoxic IMRT study

    Directory of Open Access Journals (Sweden)

    Yat Tsang

    2017-10-01

    Conclusion: This multi-centre dosimetry audit of complex IMRT/VMAT delivery provides confidence in the accuracy of modern planning and delivery systems in inhomogeneous tissues. The findings from this study can be used as a reference for future dosimetry audits.

  16. Time-dependent cell disintegration kinetics in lung tumors after irradiation

    International Nuclear Information System (INIS)

    Chvetsov, Alexei V; Palta, Jatinder J; Nagata, Yasushi

    2008-01-01

    We study the time-dependent disintegration kinetics of tumor cells that did not survive radiotherapy treatment. To evaluate the cell disintegration rate after irradiation, we studied the volume changes of solitary lung tumors after stereotactic radiotherapy. The analysis is performed using two approximations: (1) tumor volume is a linear function of the total cell number in the tumor and (2) the cell disintegration rate is governed by the exponential decay with constant risk, which is defined by the initial cell number and a half-life T 1/2 . The half-life T 1/2 is determined using the least-squares fit to the clinical data on lung tumor size variation with time after stereotactic radiotherapy. We show that the tumor volume variation after stereotactic radiotherapy of solitary lung tumors can be approximated by an exponential function. A small constant component in the volume variation does not change with time; however, this component may be the residual irregular density due to radiation fibrosis and was, therefore, subtracted from the total volume variation in our computations. Using computerized fitting of the exponent function to the clinical data for selected patients, we have determined that the average half-life T 1/2 of cell disintegration is 28.2 days for squamous cell carcinoma and 72.4 days for adenocarcinoma. This model is needed for simulating the tumor volume variation during radiotherapy, which may be important for time-dependent treatment planning of proton therapy that is sensitive to density variations

  17. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors

    International Nuclear Information System (INIS)

    Nambu, Atsushi; Marino, Kan; Koshiishi, Tsuyota; Sawada, Eiichi; Araki, Tsutomu; Onishi, Hiroshi; Aoki, Shinichi; Tominaga, Licht; Kuriyama, Kengo; Araya, Masayuki; Saito, Ryoh; Maehata, Yoshiyasu; Komiyama, Takafumi

    2013-01-01

    As stereotactic body radiotherapy (SBRT) is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT). The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED) was calculated with a range of α/β ratios (1–10 Gy). Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41), and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients

  18. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors

    Directory of Open Access Journals (Sweden)

    Nambu Atsushi

    2013-02-01

    Full Text Available Abstract Background As stereotactic body radiotherapy (SBRT is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Methods Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT. The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED was calculated with a range of α/β ratios (1–10 Gy. Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Results Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41, and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Conclusions Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients.

  19. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors

    Science.gov (United States)

    2013-01-01

    Background As stereotactic body radiotherapy (SBRT) is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Methods Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT). The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED) was calculated with a range of α/β ratios (1–10 Gy). Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Results Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41), and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Conclusions Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients. PMID:23391264

  20. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors.

    Science.gov (United States)

    Nambu, Atsushi; Onishi, Hiroshi; Aoki, Shinichi; Tominaga, Licht; Kuriyama, Kengo; Araya, Masayuki; Saito, Ryoh; Maehata, Yoshiyasu; Komiyama, Takafumi; Marino, Kan; Koshiishi, Tsuyota; Sawada, Eiichi; Araki, Tsutomu

    2013-02-07

    As stereotactic body radiotherapy (SBRT) is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT). The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED) was calculated with a range of α/β ratios (1-10 Gy). Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41), and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients.

  1. Poster — Thur Eve — 32: Stereotactic Body Radiation Therapy for Peripheral Lung Lesion: Treatment Planning and Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Shuying; Oliver, Michael; Wang, Xiaofang [Northeast Cancer Centre, Health Sciences North, Sudbury, Ontario (Canada)

    2014-08-15

    Stereotactic body radiation therapy (SBRT), due to its high precision for target localizing, has become widely used to treat tumours at various locations, including the lungs. Lung SBRT program was started at our institution a year ago. Eighteen patients with peripheral lesions up to 3 cm diameter have been treated with 48 Gy in 4 fractions. Based on four-dimensional computed tomography (4DCT) simulation, internal target volume (ITV) was delineated to encompass the respiratory motion of the lesion. A margin of 5 mm was then added to create the planning target volume (PTV) for setup uncertainties. There was no expansion from gross tumour volume (GTV) to clinical target volume (CTV). Pinnacle 9.6 was used as the primary treatment planning system. Volumetric modulated arc therapy (VMAT) technique, with one or two coplanar arcs, generally worked well. For quality assurance (QA), each plan was exported to Eclipse 10 and dose calculation was repeated. Dose volume histograms (DVHs) of the targets and organs at risk (OARs) were then compared between the two treatment planning systems. Winston-Lutz tests were carried out as routine machine QA. Patient-specific QA included ArcCheck measurement with an insert, where an ionization chamber was placed at the centre to measure dose at the isocenter. For the first several patients, and subsequently for the plans with extremely strong modulation, Gafchromic film dosimetry was also employed. For each patient, a mock setup was scheduled prior to treatments. Daily pre- and post-CBCT were acquired for setup and assessment of intra-fractional motion, respectively.

  2. No Clinically Significant Changes in Pulmonary Function Following Stereotactic Body Radiation Therapy for Early- Stage Peripheral Non-Small Cell Lung Cancer: An Analysis of RTOG 0236

    Energy Technology Data Exchange (ETDEWEB)

    Stanic, Sinisa, E-mail: sinisa.stanic@carle.com [Carle Cancer Center and University of Illinois College of Medicine, Urbana, Illinois (United States); Paulus, Rebecca [Radiation Therapy Oncology Group Statistical Center, Philadelphia, Pennsylvania (United States); Timmerman, Robert D. [University of Texas Southwestern, Dallas, Texas (United States); Michalski, Jeff M. [Washington University, St. Louis, Missouri (United States); Barriger, Robert B. [Indiana University, Indianapolis, Indiana (United States); Bezjak, Andrea [Princess Margaret Cancer Center, Toronto, Ontario (Canada); Videtic, Gregory M.M. [Cleveland Clinic Foundation, Cleveland, Ohio (United States); Bradley, Jeffrey [Washington University, St. Louis, Missouri (United States)

    2014-04-01

    Purpose: To investigate pulmonary function test (PFT) results and arterial blood gas changes (complete PFT) following stereotactic body radiation therapy (SBRT) and to see whether baseline PFT correlates with lung toxicity and overall survival in medically inoperable patients receiving SBRT for early stage, peripheral, non-small cell lung cancer (NSCLC). Methods and Materials: During the 2-year follow-up, PFT data were collected for patients with T1-T2N0M0 peripheral NSCLC who received effectively 18 Gy × 3 in a phase 2 North American multicenter study (Radiation Therapy Oncology Group [RTOG] protocol 0236). Pulmonary toxicity was graded by using the RTOG SBRT pulmonary toxicity scale. Paired Wilcoxon signed rank test, logistic regression model, and Kaplan-Meier method were used for statistical analysis. Results: At 2 years, mean percentage predicted forced expiratory volume in the first second and diffusing capacity for carbon monoxide declines were 5.8% and 6.3%, respectively, with minimal changes in arterial blood gases and no significant decline in oxygen saturation. Baseline PFT was not predictive of any pulmonary toxicity following SBRT. Whole-lung V5 (the percentage of normal lung tissue receiving 5 Gy), V10, V20, and mean dose to the whole lung were almost identical between patients who developed pneumonitis and patients who were pneumonitis-free. Poor baseline PFT did not predict decreased overall survival. Patients with poor baseline PFT as the reason for medical inoperability had higher median and overall survival rates than patients with normal baseline PFT values but with cardiac morbidity. Conclusions: Poor baseline PFT did not appear to predict pulmonary toxicity or decreased overall survival after SBRT in this medically inoperable population. Poor baseline PFT alone should not be used to exclude patients with early stage lung cancer from treatment with SBRT.

  3. No Clinically Significant Changes in Pulmonary Function Following Stereotactic Body Radiation Therapy for Early- Stage Peripheral Non-Small Cell Lung Cancer: An Analysis of RTOG 0236

    International Nuclear Information System (INIS)

    Stanic, Sinisa; Paulus, Rebecca; Timmerman, Robert D.; Michalski, Jeff M.; Barriger, Robert B.; Bezjak, Andrea; Videtic, Gregory M.M.; Bradley, Jeffrey

    2014-01-01

    Purpose: To investigate pulmonary function test (PFT) results and arterial blood gas changes (complete PFT) following stereotactic body radiation therapy (SBRT) and to see whether baseline PFT correlates with lung toxicity and overall survival in medically inoperable patients receiving SBRT for early stage, peripheral, non-small cell lung cancer (NSCLC). Methods and Materials: During the 2-year follow-up, PFT data were collected for patients with T1-T2N0M0 peripheral NSCLC who received effectively 18 Gy × 3 in a phase 2 North American multicenter study (Radiation Therapy Oncology Group [RTOG] protocol 0236). Pulmonary toxicity was graded by using the RTOG SBRT pulmonary toxicity scale. Paired Wilcoxon signed rank test, logistic regression model, and Kaplan-Meier method were used for statistical analysis. Results: At 2 years, mean percentage predicted forced expiratory volume in the first second and diffusing capacity for carbon monoxide declines were 5.8% and 6.3%, respectively, with minimal changes in arterial blood gases and no significant decline in oxygen saturation. Baseline PFT was not predictive of any pulmonary toxicity following SBRT. Whole-lung V5 (the percentage of normal lung tissue receiving 5 Gy), V10, V20, and mean dose to the whole lung were almost identical between patients who developed pneumonitis and patients who were pneumonitis-free. Poor baseline PFT did not predict decreased overall survival. Patients with poor baseline PFT as the reason for medical inoperability had higher median and overall survival rates than patients with normal baseline PFT values but with cardiac morbidity. Conclusions: Poor baseline PFT did not appear to predict pulmonary toxicity or decreased overall survival after SBRT in this medically inoperable population. Poor baseline PFT alone should not be used to exclude patients with early stage lung cancer from treatment with SBRT

  4. An analysis of tolerance levels in IMRT quality assurance procedures

    International Nuclear Information System (INIS)

    Basran, Parminder S.; Woo, Milton K.

    2008-01-01

    Increased use of intensity modulated radiation therapy (IMRT) has resulted in increased efforts in patient quality assurance (QA). Software and detector systems intended to streamline the IMRT quality assurance process often report metrics, such as percent discrepancies between measured and computed doses, which can be compared to benchmark or threshold values. The purpose of this work is to examine the relationships between two different types of IMRT QA processes in order to define, or refine, appropriate tolerances values. For 115 IMRT plans delivered in a 3 month period, we examine the discrepancies between (a) the treatment planning system (TPS) and results from a commercial independent monitor unit (MU) calculation program; (b) TPS and results from a commercial diode-array measurement system; and (c) the independent MU calculation and the diode-array measurements. Statistical tests were performed to assess significance in the IMRT QA results for different disease site and machine models. There is no evidence that the average total dose discrepancy in the monitor unit calculation depends on the disease site. Second, the discrepancies in the two IMRT QA methods are independent: there is no evidence that a better --or worse--monitor unit validation result is related to a better--or worse--diode-array measurement result. Third, there is marginal benefit in repeating the independent MU calculation with a more suitable dose point, if the initial IMRT QA failed a certain tolerance. Based on these findings, the authors conclude at some acceptable tolerances based on disease site and IMRT QA method. Specifically, monitor unit validations are expected to have a total dose discrepancy of 3% overall, and 5% per beam, independent of disease site. Diode array measurements are expected to have a total absolute dose discrepancy of 3% overall, and 3% per beam, independent of disease site. The percent of pixels exceeding a 3% and 3 mm threshold in a gamma analysis should be

  5. Predictive factors of symptomatic radiation pneumonitis in primary and metastatic lung tumors treated with stereotactic ablative body radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Pyo; Lee, Jeong Shim; Cho, Yeona; Chung, Seung Yeun; Lee, Jason Joon Bock; Lee, Chang Geol; Cho, Jae Ho [Dept. of Radiation Oncology, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Although stereotactic ablative body radiotherapy (SABR) is widely used therapeutic technique, predictive factors of radiation pneumonitis (RP) after SABR remain undefined. We aimed to investigate the predictive factors affecting RP in patients with primary or metastatic lung tumors who received SABR. From 2012 to 2015, we reviewed 59 patients with 72 primary or metastatic lung tumors treated with SABR, and performed analyses of clinical and dosimetric variables related to symptomatic RP. SABR was delivered as 45–60 Gy in 3–4 fractions, which were over 100 Gy in BED when the α/β value was assumed to be 10. Tumor volume and other various dose volume factors were analyzed using median value as a cutoff value. RP was graded per the Common Terminology Criteria for Adverse Events v4.03. At the median follow-up period of 11 months, symptomatic RP was observed in 13 lesions (12 patients, 18.1%), including grade 2 RP in 11 lesions and grade 3 in 2 lesions. Patients with planning target volume (PTV) of ≤14.35 mL had significantly lower rates of symptomatic RP when compared to others (8.6% vs. 27%; p = 0.048). Rates of symptomatic RP in patients with internal gross tumor volume (iGTV) >4.21 mL were higher than with ≤4.21 mL (29.7% vs. 6.1%; p = 0.017). The incidence of symptomatic RP following treatment with SABR was acceptable with grade 2 RP being observed in most patients. iGTV over 4.21 mL and PTV of over 14.35 mL were significant predictive factors related to symptomatic RP.

  6. Planner concepts in IMRT planning

    International Nuclear Information System (INIS)

    Sahoo, Suvendu Kr.; Rath, A.K.; Patnaik, S.; Mishra, S.K.

    2008-01-01

    IMRT is the most sophisticated, innovative, three- dimensional conformal radiation treatment that delivers highly focused radiation with minimal impact to surrounding normal tissue. As it is a computer control technique, the planar should have adequate knowledge to execute the plan in proper way other wise it is very difficult to get the optimal plan. In this article we want to high light, planner should have the basic concepts before starting the IMRT planning

  7. An examination of the number of required apertures for step-and-shoot IMRT

    International Nuclear Information System (INIS)

    Jiang, Z; Earl, M A; Zhang, G W; Yu, C X; Shepard, D M

    2005-01-01

    We have examined the degree to which step-and-shoot IMRT treatment plans can be simplified (using a small number of apertures) without sacrificing the dosimetric quality of the plans. A key element of this study was the use of direct aperture optimization (DAO), an inverse planning technique where all of the multi-leaf collimator constraints are incorporated into the optimization. For seven cases (1 phantom, 1 prostate, 3 head-and-neck and 2 lung), DAO was used to perform a series of optimizations where the number of apertures per beam direction varied from 1 to 15. In this work, we attempt to provide general guidelines for how many apertures per beam direction are sufficient for various clinical cases using DAO. Analysis of the optimized treatment plans reveals that for most cases, only modest improvements in the objective function and the corresponding DVHs are seen beyond 5 apertures per beam direction. However, for more complex cases, some dosimetric gain can be achieved by increasing the number of apertures per beam direction beyond 5. Even in these cases, however, only modest improvements are observed beyond 9 apertures per beam direction. In our clinical experience, 38 out of the first 40 patients treated using IMRT plans produced using DAO were treated with 9 or fewer apertures per beam direction. The results indicate that many step-and-shoot IMRT treatment plans delivered today are more complex than necessary and can be simplified without sacrificing plan quality

  8. Direct aperture optimization for IMRT using Monte Carlo generated beamlets

    International Nuclear Information System (INIS)

    Bergman, Alanah M.; Bush, Karl; Milette, Marie-Pierre; Popescu, I. Antoniu; Otto, Karl; Duzenli, Cheryl

    2006-01-01

    This work introduces an EGSnrc-based Monte Carlo (MC) beamlet does distribution matrix into a direct aperture optimization (DAO) algorithm for IMRT inverse planning. The technique is referred to as Monte Carlo-direct aperture optimization (MC-DAO). The goal is to assess if the combination of accurate Monte Carlo tissue inhomogeneity modeling and DAO inverse planning will improve the dose accuracy and treatment efficiency for treatment planning. Several authors have shown that the presence of small fields and/or inhomogeneous materials in IMRT treatment fields can cause dose calculation errors for algorithms that are unable to accurately model electronic disequilibrium. This issue may also affect the IMRT optimization process because the dose calculation algorithm may not properly model difficult geometries such as targets close to low-density regions (lung, air etc.). A clinical linear accelerator head is simulated using BEAMnrc (NRC, Canada). A novel in-house algorithm subdivides the resulting phase space into 2.5x5.0 mm 2 beamlets. Each beamlet is projected onto a patient-specific phantom. The beamlet dose contribution to each voxel in a structure-of-interest is calculated using DOSXYZnrc. The multileaf collimator (MLC) leaf positions are linked to the location of the beamlet does distributions. The MLC shapes are optimized using direct aperture optimization (DAO). A final Monte Carlo calculation with MLC modeling is used to compute the final dose distribution. Monte Carlo simulation can generate accurate beamlet dose distributions for traditionally difficult-to-calculate geometries, particularly for small fields crossing regions of tissue inhomogeneity. The introduction of DAO results in an additional improvement by increasing the treatment delivery efficiency. For the examples presented in this paper the reduction in the total number of monitor units to deliver is ∼33% compared to fluence-based optimization methods

  9. Emerging technologies in stereotactic body radiotherapy.

    Science.gov (United States)

    Ma, Lijun; Wang, Lei; Tseng, Chia-Lin; Sahgal, Arjun

    2017-09-01

    Stereotactic body radiation therapy (SBRT) stems from the initial developments of intra-cranial stereotactic radiosurgery (SRS). Despite similarity in their names and clinical goals of delivering a sufficiently high tumoricidal dose, maximal sparing of the surrounding normal tissues and a short treatment course, SBRT technologies have transformed from the early days of body frame-based treatments with X-ray verification to primarily image-guided procedures with cone-beam CT or stereoscopic X-ray systems and non-rigid body immo-bilization. As a result of the incorporation of image-guidance systems and multi-leaf col-limators into mainstream linac systems, and treatment planning systems that have also evolved to allow for routine dose calculations to permit intensity modulated radiotherapy and volumetric modulated arc therapy (VMAT), SBRT has disseminated rapidly in the community to manage many disease sites that include oligometastases, spine lesions, lung, prostate, liver, renal cell, pelvic tumors, and head and neck tumors etc. In this article, we review the physical principles and paradigms that led to the widespread adoption of SBRT practice as well as technical caveats specific to individual SBRT technologies. From the perspective of treatment delivery, we categorically described (I) C-arm linac-based SBRT technologies; (II) robotically manipulated X-band CyberKnife® technology; and (III) emerging specialized systems for SBRT that include integrated MRI-linear accelerators and the imaged-guided Gamma Knife Perfexion Icon system with expanded multi-isocenter treatments of skull-based tumors, head-and-neck and cervical-spine lesions.

  10. Fast IMRT by increasing the beam number and reducing the number of segments

    International Nuclear Information System (INIS)

    Bratengeier, Klaus; Gainey, Mark B; Flentje, Michael

    2011-01-01

    The purpose of this work is to develop fast deliverable step and shoot IMRT technique. A reduction in the number of segments should theoretically be possible, whilst simultaneously maintaining plan quality, provided that the reduction is accompanied by an increased number of gantry angles. A benefit of this method is that the segment shaping could be performed during gantry motion, thereby reducing the delivery time. The aim was to find classes of such solutions whose plan quality can compete with conventional IMRT. A planning study was performed. Step and shoot IMRT plans were created using direct machine parameter optimization (DMPO) as a reference. DMPO plans were compared to an IMRT variant having only one segment per angle ('2-Step Fast'). 2-Step Fast is based on a geometrical analysis of the topology of the planning target volume (PTV) and the organs at risk (OAR). A prostate/rectum case, spine metastasis/spinal cord, breast/lung and an artificial PTV/OAR combination of the ESTRO-Quasimodo phantom were used for the study. The composite objective value (COV), a quality score, and plan delivery time were compared. The delivery time for the DMPO reference plan and the 2-Step Fast IMRT technique was measured and calculated for two different linacs, a twelve year old Siemens Primus™ ('old' linac) and two Elekta Synergy™ 'S' linacs ('new' linacs). 2-Step Fast had comparable or better quality than the reference DMPO plan. The number of segments was smaller than for the reference plan, the number of gantry angles was between 23 and 34. For the modern linac the delivery time was always smaller than that for the reference plan. The calculated (measured) values showed a mean delivery time reduction of 21% (21%) for the new linac, and of 7% (3%) for the old linac compared to the respective DMPO reference plans. For the old linac, the data handling time per beam was the limiting factor for the treatment time reduction. 2-Step

  11. Fast IMRT by increasing the beam number and reducing the number of segments

    Directory of Open Access Journals (Sweden)

    Bratengeier Klaus

    2011-12-01

    Full Text Available Abstract Purpose The purpose of this work is to develop fast deliverable step and shoot IMRT technique. A reduction in the number of segments should theoretically be possible, whilst simultaneously maintaining plan quality, provided that the reduction is accompanied by an increased number of gantry angles. A benefit of this method is that the segment shaping could be performed during gantry motion, thereby reducing the delivery time. The aim was to find classes of such solutions whose plan quality can compete with conventional IMRT. Materials/Methods A planning study was performed. Step and shoot IMRT plans were created using direct machine parameter optimization (DMPO as a reference. DMPO plans were compared to an IMRT variant having only one segment per angle ("2-Step Fast". 2-Step Fast is based on a geometrical analysis of the topology of the planning target volume (PTV and the organs at risk (OAR. A prostate/rectum case, spine metastasis/spinal cord, breast/lung and an artificial PTV/OAR combination of the ESTRO-Quasimodo phantom were used for the study. The composite objective value (COV, a quality score, and plan delivery time were compared. The delivery time for the DMPO reference plan and the 2-Step Fast IMRT technique was measured and calculated for two different linacs, a twelve year old Siemens Primus™ ("old" linac and two Elekta Synergy™ "S" linacs ("new" linacs. Results 2-Step Fast had comparable or better quality than the reference DMPO plan. The number of segments was smaller than for the reference plan, the number of gantry angles was between 23 and 34. For the modern linac the delivery time was always smaller than that for the reference plan. The calculated (measured values showed a mean delivery time reduction of 21% (21% for the new linac, and of 7% (3% for the old linac compared to the respective DMPO reference plans. For the old linac, the data handling time per beam was the limiting factor for the treatment time

  12. Statistical process control analysis for patient-specific IMRT and VMAT QA.

    Science.gov (United States)

    Sanghangthum, Taweap; Suriyapee, Sivalee; Srisatit, Somyot; Pawlicki, Todd

    2013-05-01

    This work applied statistical process control to establish the control limits of the % gamma pass of patient-specific intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) quality assurance (QA), and to evaluate the efficiency of the QA process by using the process capability index (Cpml). A total of 278 IMRT QA plans in nasopharyngeal carcinoma were measured with MapCHECK, while 159 VMAT QA plans were undertaken with ArcCHECK. Six megavolts with nine fields were used for the IMRT plan and 2.5 arcs were used to generate the VMAT plans. The gamma (3%/3 mm) criteria were used to evaluate the QA plans. The % gamma passes were plotted on a control chart. The first 50 data points were employed to calculate the control limits. The Cpml was calculated to evaluate the capability of the IMRT/VMAT QA process. The results showed higher systematic errors in IMRT QA than VMAT QA due to the more complicated setup used in IMRT QA. The variation of random errors was also larger in IMRT QA than VMAT QA because the VMAT plan has more continuity of dose distribution. The average % gamma pass was 93.7% ± 3.7% for IMRT and 96.7% ± 2.2% for VMAT. The Cpml value of IMRT QA was 1.60 and VMAT QA was 1.99, which implied that the VMAT QA process was more accurate than the IMRT QA process. Our lower control limit for % gamma pass of IMRT is 85.0%, while the limit for VMAT is 90%. Both the IMRT and VMAT QA processes are good quality because Cpml values are higher than 1.0.

  13. Interrater Reliability of the Categorization of Late Radiographic Changes After Lung Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Faruqi, Salman [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, ON (Canada); Giuliani, Meredith E., E-mail: meredith.giuliani@rmp.uhn.on.ca [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, ON (Canada); Raziee, Hamid; Yap, Mei Ling [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, ON (Canada); Roberts, Heidi [Department of Radiology, University Health Network, Toronto, Ontario (Canada); Le, Lisa W. [Department of Biostatistics, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Brade, Anthony; Cho, John; Sun, Alexander; Bezjak, Andrea; Hope, Andrew J. [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, ON (Canada)

    2014-08-01

    Purpose: Radiographic changes after lung stereotactic body radiation therapy (SBRT) have been categorized into 4 groups: modified conventional pattern (A), mass-like fibrosis; (B), scar-like fibrosis (C), and no evidence of increased density (D). The purpose of this study was to assess the interrater reliability of this categorization system in patients with early-stage non-small cell lung cancer (NSCLC). Methods and Materials: Seventy-seven patients were included in this study, all treated with SBRT for early-stage (T1/2) NSCLC at a single institution, with a minimum follow-up of 6 months. Six experienced clinicians familiar with post-SBRT radiographic changes scored the serial posttreatment CT images independently in a blinded fashion. The proportion of patients categorized as A, B, C, or D at each interval was determined. Krippendorff's alpha (KA), Multirater kappa (M-kappa), and Gwet's AC1 (AC1) scores were used to establish interrater reliability. A leave-one-out analysis was performed to demonstrate the variability among raters. Interrater agreement of the first and last 20 patients scored was calculated to explore whether a training effect existed. Results: The number of ratings ranged from 450 at 6 months to 84 at 48 months of follow-up. The proportion of patients in each category was as follows: A, 45%; B, 16%; C, 13%; and D, 26%. KA and M-kappa ranged from 0.17 to 0.34. AC1 measure range was 0.22 to 0.48. KA increased from 0.24 to 0.36 at 12 months with training. The percent agreement for pattern A peaked at 12 month with a 54% chance of having >50% raters in agreement and decreased over time, whereas that for patterns B and C increased over time to a maximum of 20% and 22%, respectively. Conclusion: This post-SBRT radiographic change categorization system has modest interrater agreement, and there is a suggestion of a training effect. Patterns of fibrosis evolve after SBRT and alternative categorization systems should be evaluated.

  14. Mortality following single-fraction stereotactic body radiation therapy for central pulmonary oligometastasis.

    Science.gov (United States)

    Ma, Sung Jun; Mix, Michael; Rivers, Charlotte; Hennon, Mark; Gomez, Jorge; Singh, Anurag K

    2017-01-01

    The case of a 56-year-old male who developed bronchopulmonary hemorrhage after a course of stereotactic body radiation therapy (SBRT) for centrally located squamous cell lung carcinoma is presented. The patient was previously treated with concurrent chemoradiation for stage IVA squamous cell carcinoma of the base of tongue. He showed no evidence of disease for 4 years until he developed a solitary metastasis of squamous cell carcinoma in the right hilum. He underwent a single fraction of 26 Gy with heterogeneity correction. He showed no evidence of disease for 13 months until he developed a sudden grade 4 bronchopulmonary hemorrhage. He underwent an urgent right pneumonectomy and later died of a post-operative complication. Pathologic analysis of the specimen revealed no evidence of tumor. Single-fraction SBRT of 26 Gy was sufficient to achieve complete response of his large central lung tumor. However, when treating patients with central lung tumors, some risk of mortality may be unavoidable with either SBRT or pneumonectomy.

  15. Curative Treatment of Stage I Non-Small-Cell Lung Cancer in Patients With Severe COPD: Stereotactic Radiotherapy Outcomes and Systematic Review

    International Nuclear Information System (INIS)

    Palma, David; Lagerwaard, Frank; Rodrigues, George; Haasbeek, Cornelis; Senan, Suresh

    2012-01-01

    Objectives: Patients with severe chronic obstructive pulmonary disease (COPD) have a high risk of lung cancer and of postsurgical complications. We studied outcomes after stereotactic body radiotherapy (SBRT) in patients with severe COPD, as defined by Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria, and performed a systematic review of the literature on outcomes after SBRT or surgery in these patients. Methods: A single-institution cohort of 176 patients with COPD GOLD III-IV and Stage I non–small-cell lung cancer (NSCLC) treated with SBRT was evaluated. A systematic review identified studies reporting outcomes after SBRT or surgery for Stage I NSCLC in patients with GOLD III-IV or a predicted postoperative forced expiratory volume in 1 second (FEV1) of ≤40%. Results: In the single-institution cohort, median follow-up was 21 months and median overall survival (OS) was 32 months. Actuarial 3-year local control was 89%, and 1- and 3-year OS were 79% and 47%, respectively. COPD severity correlated with OS (p = 0.01). The systematic review identified four other studies (two surgical, two SBRT, n = 196 patients). SBRT studies were published more recently and included older patients than surgical studies. Mean 30-day mortality was 0% post-SBRT and 10% after surgery. Local or locoregional control was high (≥89%) after both treatments. Post-SBRT, actuarial OS was 79–95% at 1 year and 43–70% at 3 years. Postsurgical actuarial OS was 45–86% at 1 year and 31–66% at 3 years. Conclusions: SBRT and surgery differ in risk of 30-day mortality in patients with severe COPD. Despite the negative selection of SBRT patients, survival at 1 and 3 years is comparable between the two treatments.

  16. Salvage stereotactic body radiotherapy for locally recurrent non-small cell lung cancer after sublobar resection and I125 vicryl mesh brachytherapy

    Directory of Open Access Journals (Sweden)

    Beant Singh Gill

    2015-05-01

    Full Text Available Purpose: Locally-recurrent non-small cell lung cancer (LR-NSCLC remains challenging treat, particularly in patients having received prior radiotherapy. Heterogeneous populations and varied treatment intent in existing literature result in significant limitations in evaluating efficacy of lung re-irradiation. In order to better establish the impact of re-irradiation in patients with LR-NSCLC following high-dose radiotherapy, we report outcomes for patients treated with prior sublobar resection and brachytherapy that subsequently underwent stereotactic body radiotherapy (SBRT.Methods: A retrospective review of patients initially treated with sublobar resection and I125 vicryl mesh brachytherapy, who later developed LR-NSCLC along the suture line, was performed. Patients received salvage SBRT with curative intent. Dose and fractionation was based on tumor location and size, with a median prescription dose of 48 Gy in 4 fractions (range 20-60 Gy in 1-4 fractions.Results: Thirteen consecutive patients were identified with median follow-up of 2.1 years (range 0.7-5.6 years. Two in-field local failures occurred at 7.5 and 11.1 months, resulting in 2-year local control of 83.9% (95% CI 63.5-100.0%. Two-year disease-free survival and overall survival estimates were 38.5% (95% CI 0.0-65.0% and 65.8% (95% CI, 38.2-93.4%. Four patients (31% remained disease-free at last follow-up. All but one patient who experienced disease recurrence developed isolated or synchronous distant metastases. Only one patient (7.7% developed grade ≥3 toxicity, consisting of grade 3 esophageal stricture following a centrally located recurrence previously treated with radiofrequency ablation.Conclusion: Despite high local radiation doses delivered to lung parenchyma previously with I125 brachytherapy, re-irradiation with SBRT for LR-NSCLC results in excellent local control with limited morbidity, allowing for potential disease cure in a subset of patients.

  17. Curative Treatment of Stage I Non-Small-Cell Lung Cancer in Patients With Severe COPD: Stereotactic Radiotherapy Outcomes and Systematic Review

    Energy Technology Data Exchange (ETDEWEB)

    Palma, David, E-mail: david.palma@uwo.ca [VU University Medical Center, Amsterdam (Netherlands); Division of Radiation Oncology, London Regional Cancer Program, London, Ontario (Canada); Lagerwaard, Frank [VU University Medical Center, Amsterdam (Netherlands); Rodrigues, George [Division of Radiation Oncology, London Regional Cancer Program, London, Ontario (Canada); Haasbeek, Cornelis; Senan, Suresh [VU University Medical Center, Amsterdam (Netherlands)

    2012-03-01

    Objectives: Patients with severe chronic obstructive pulmonary disease (COPD) have a high risk of lung cancer and of postsurgical complications. We studied outcomes after stereotactic body radiotherapy (SBRT) in patients with severe COPD, as defined by Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria, and performed a systematic review of the literature on outcomes after SBRT or surgery in these patients. Methods: A single-institution cohort of 176 patients with COPD GOLD III-IV and Stage I non-small-cell lung cancer (NSCLC) treated with SBRT was evaluated. A systematic review identified studies reporting outcomes after SBRT or surgery for Stage I NSCLC in patients with GOLD III-IV or a predicted postoperative forced expiratory volume in 1 second (FEV1) of {<=}40%. Results: In the single-institution cohort, median follow-up was 21 months and median overall survival (OS) was 32 months. Actuarial 3-year local control was 89%, and 1- and 3-year OS were 79% and 47%, respectively. COPD severity correlated with OS (p = 0.01). The systematic review identified four other studies (two surgical, two SBRT, n = 196 patients). SBRT studies were published more recently and included older patients than surgical studies. Mean 30-day mortality was 0% post-SBRT and 10% after surgery. Local or locoregional control was high ({>=}89%) after both treatments. Post-SBRT, actuarial OS was 79-95% at 1 year and 43-70% at 3 years. Postsurgical actuarial OS was 45-86% at 1 year and 31-66% at 3 years. Conclusions: SBRT and surgery differ in risk of 30-day mortality in patients with severe COPD. Despite the negative selection of SBRT patients, survival at 1 and 3 years is comparable between the two treatments.

  18. Localization Accuracy and Immobilization Effectiveness of a Stereotactic Body Frame for a Variety of Treatment Sites

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Ryan, E-mail: Ryan.Foster@utsouthwestern.edu [Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas (United States); Meyer, Jeffrey; Iyengar, Puneeth; Pistenmaa, David; Timmerman, Robert; Choy, Hak [Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas (United States); Solberg, Timothy [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2013-12-01

    Purpose: The purpose of this study was to analyze the pretreatment setup errors and intrafraction motion using cone beam computed tomography (CBCT) for stereotactic body radiation therapy patients immobilized and localized with a stereotactic body frame for a variety of treatment sites. Methods and Materials: Localization errors were recorded for patients receiving SBRT for 141 lung, 29 liver, 48 prostate, and 45 spine tumors representing 1005 total localization sessions. All patients were treated in a stereotactic body frame with a large custom-molded vacuum pillow. Patients were first localized to the frame using tattoos placed during simulation. Subsequently, the frame was aligned to the room lasers according to the stereotactic coordinates determined from the treatment plan. Every patient received a pretreatment and an intrafraction CBCT. Abdominal compression was used for all liver patients and for approximately 40% of the lung patients to reduce tumor motion due to respiration. Results: The mean ± standard deviation pretreatment setup errors from all localizations were −2.44 ± 3.85, 1.31 ± 5.84, and 0.11 ± 3.76 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean pretreatment localization results among all treatment sites were not significantly different (F test, P<.05). For all treatment sites, the mean ± standard deviation intrafraction shifts were 0.33 ± 1.34, 0.15 ± 1.45, and −0.02 ± 1.17 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean unidimensional intrafraction shifts were statistically different for several of the comparisons (P<.05) as assessed by the Tukey-Kramer test. Conclusions: Despite the varied tumor locations, the pretreatment mean localization errors for all sites were found to be consistent among the treatment sites and not significantly different, indicating that the body frame is a suitable immobilization and localization device for a variety of

  19. Localization Accuracy and Immobilization Effectiveness of a Stereotactic Body Frame for a Variety of Treatment Sites

    International Nuclear Information System (INIS)

    Foster, Ryan; Meyer, Jeffrey; Iyengar, Puneeth; Pistenmaa, David; Timmerman, Robert; Choy, Hak; Solberg, Timothy

    2013-01-01

    Purpose: The purpose of this study was to analyze the pretreatment setup errors and intrafraction motion using cone beam computed tomography (CBCT) for stereotactic body radiation therapy patients immobilized and localized with a stereotactic body frame for a variety of treatment sites. Methods and Materials: Localization errors were recorded for patients receiving SBRT for 141 lung, 29 liver, 48 prostate, and 45 spine tumors representing 1005 total localization sessions. All patients were treated in a stereotactic body frame with a large custom-molded vacuum pillow. Patients were first localized to the frame using tattoos placed during simulation. Subsequently, the frame was aligned to the room lasers according to the stereotactic coordinates determined from the treatment plan. Every patient received a pretreatment and an intrafraction CBCT. Abdominal compression was used for all liver patients and for approximately 40% of the lung patients to reduce tumor motion due to respiration. Results: The mean ± standard deviation pretreatment setup errors from all localizations were −2.44 ± 3.85, 1.31 ± 5.84, and 0.11 ± 3.76 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean pretreatment localization results among all treatment sites were not significantly different (F test, P<.05). For all treatment sites, the mean ± standard deviation intrafraction shifts were 0.33 ± 1.34, 0.15 ± 1.45, and −0.02 ± 1.17 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean unidimensional intrafraction shifts were statistically different for several of the comparisons (P<.05) as assessed by the Tukey-Kramer test. Conclusions: Despite the varied tumor locations, the pretreatment mean localization errors for all sites were found to be consistent among the treatment sites and not significantly different, indicating that the body frame is a suitable immobilization and localization device for a variety of

  20. Stereotactic radiotherapy in pediatric indications

    International Nuclear Information System (INIS)

    Bernier-Chastagner, V.; Supiot, S.; Carrie, C.; Helfre, S.

    2012-01-01

    Stereotactic radiotherapy is a very high precision procedure, which has been limited to radiosurgery for a long time. Technological improvements allowed the development of radiotherapy in stereotactic conditions, leading to a lot of innovations. Previously indicated for cerebral pathologies, this procedure is now developed for extra-cerebral locations. In paediatrics, stereotactic radiotherapy is still limited, delivered precociously, due to the possibility of long-term late effects that needs to be addressed. This review reports the different useful conditions, technical evolutions, and the current validated paediatric indications, with differences from adults, and future directions. (authors)

  1. DEGRO 2012. 18. annual congress of the German Radiation Oncology Society. Radiation oncology - medical physics - radiation biology. Abstracts

    International Nuclear Information System (INIS)

    Anon.

    2012-01-01

    The volume includes the abstracts of the contributions and posters of the 18th annual congress of the German Radiation Oncology Society DEGRO 2012. The lectures covered the following topics: Radiation physics, therapy planning; gastrointestinal tumors; radiation biology; stererotactic radiotherapy/breast carcinomas; quality management - life quality; head-neck-tumors/lymphomas; NSCL (non-small cell lung carcinomas); pelvic tumors; brain tumors/pediatric tumors. The poster sessions included the following topics: quality management, recurrent tumor therapy; brachytherapy; breast carcinomas and gynecological tumors; pelvis tumors; brain tumors; stereotactic radiotherapy; head-neck carcinomas; NSCL, proton therapy, supporting therapy; clinical radio-oncology, radiation biology, IGRT/IMRT.

  2. Translational and rotational intra- and inter-fractional errors in patient and target position during a short course of frameless stereotactic body radiotherapy

    DEFF Research Database (Denmark)

    Josipovic, Mirjana; Persson, Gitte Fredberg; Logadottir, Ashildur

    2012-01-01

    Implementation of cone beam computed tomography (CBCT) in frameless stereotactic body radiotherapy (SBRT) of lung tumours enables setup correction based on tumour position. The aim of this study was to compare setup accuracy with daily soft tissue matching to bony anatomy matching and evaluate...

  3. SU-F-T-622: Comparative Analysis of Pencil Beam and Anisotropic Analytical Algorithm (AAA) for Stereotactic Body Radiation Therapy (SBRT) of Thoracic Spine

    Energy Technology Data Exchange (ETDEWEB)

    Badkul, R; Nicolai, W; Pokhrel, D; Jiang, H; Wang, F; Lominskac, C [University of Kansas Medical Center, Kansas City, KS (United States); Ramanjappa, T [S. K. University, Anantapur, AP (India)

    2016-06-15

    Purpose: To compare the impact of Pencil Beam(PB) and Anisotropic Analytic Algorithm(AAA) dose calculation algorithms on OARs and planning target volume (PTV) in thoracic spine stereotactic body radiation therapy (SBRT). Methods: Ten Spine SBRT patients were planned on Brainlab iPlan system using hybrid plan consisting of 1–2 non-coplanar conformal-dynamic arcs and few IMRT beams treated on NovalisTx with 6MV photon. Dose prescription varied from 20Gy to 30Gy in 5 fractions depending on the situation of the patient. PB plans were retrospectively recalculated using the Varian Eclipse with AAA algorithm using same MUs, MLC pattern and grid size(3mm).Differences in dose volume parameters for PTV, spinal cord, lung, and esophagus were analyzed and compared for PB and AAA algorithms. OAR constrains were followed per RTOG-0631. Results: Since patients were treated using PB calculation, we compared all the AAA DVH values with respect to PB plan values as standard, although AAA predicts the dose more accurately than PB. PTV(min), PTV(Max), PTV(mean), PTV(D99%), PTV(D90%) were overestimated with AAA calculation on average by 3.5%, 1.84%, 0.95%, 3.98% and 1.55% respectively as compared to PB. All lung DVH parameters were underestimated with AAA algorithm mean deviation of lung V20, V10, V5, and 1000cc were 42.81%,19.83%, 18.79%, and 18.35% respectively. AAA overestimated Cord(0.35cc) by mean of 17.3%; cord (0.03cc) by 12.19% and cord(max) by 10.5% as compared to PB. Esophagus max dose were overestimated by 4.4% and 5cc by 3.26% for AAA algorithm as compared to PB. Conclusion: AAA overestimated the PTV dose values by up to 4%.The lung DVH had the greatest underestimation of dose by AAA versus PB. Spinal cord dose was overestimated by AAA versus PB. Given the critical importance of accuracy of OAR and PTV dose calculation for SBRT spine, more accurate algorithms and validation of calculated doses in phantom models are indicated.

  4. Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance.

    Science.gov (United States)

    Narayanasamy, Ganesh; Zalman, Travis; Ha, Chul S; Papanikolaou, Niko; Stathakis, Sotirios

    2015-05-08

    The purpose of this study is to evaluate the use of the Dosimetry Check system for patient-specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the patient's CT scans. Instead of making dose comparisons in a plane, Dosimetry Check system produces isodose lines and dose-volume histograms based on the planning CT images. By exporting the dose distribution from the treatment planning system into the Dosimetry Check system, one is able to make a direct comparison between the calculated dose and the planned dose. The versatility of the software is evaluated with respect to the two IMRT techniques - step and shoot and volumetric arc therapy. The system analyzed measurements made using EPID, PTW seven29, and IBA MatriXX, and an intercomparison study was performed. Plans from patients previously treated at our institution with treated anatomical site on brain, head & neck, liver, lung, and prostate were analyzed using Dosimetry Check system for any anatomical site dependence. We have recommendations and possible precautions that may be necessary to ensure proper QA with the Dosimetry Check system.

  5. Time-dependent cell disintegration kinetics in lung tumors after irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chvetsov, Alexei V; Palta, Jatinder J [Department of Radiation Oncology, University of Florida, Gainesville, FL (United States); Nagata, Yasushi [Department of Therapeutic Radiology and Oncology, Kyoto University, Kyoto (Japan)], E-mail: chvetsov@ufl.edu

    2008-05-07

    We study the time-dependent disintegration kinetics of tumor cells that did not survive radiotherapy treatment. To evaluate the cell disintegration rate after irradiation, we studied the volume changes of solitary lung tumors after stereotactic radiotherapy. The analysis is performed using two approximations: (1) tumor volume is a linear function of the total cell number in the tumor and (2) the cell disintegration rate is governed by the exponential decay with constant risk, which is defined by the initial cell number and a half-life T{sub 1/2}. The half-life T{sub 1/2} is determined using the least-squares fit to the clinical data on lung tumor size variation with time after stereotactic radiotherapy. We show that the tumor volume variation after stereotactic radiotherapy of solitary lung tumors can be approximated by an exponential function. A small constant component in the volume variation does not change with time; however, this component may be the residual irregular density due to radiation fibrosis and was, therefore, subtracted from the total volume variation in our computations. Using computerized fitting of the exponent function to the clinical data for selected patients, we have determined that the average half-life T{sub 1/2} of cell disintegration is 28.2 days for squamous cell carcinoma and 72.4 days for adenocarcinoma. This model is needed for simulating the tumor volume variation during radiotherapy, which may be important for time-dependent treatment planning of proton therapy that is sensitive to density variations.

  6. IMRT limits nephrotoxicity after chemoradiotherapy for gastric cancer

    International Nuclear Information System (INIS)

    Trip, Anouk Kirsten; Nijkamp, Jasper; Tinteren, Harm van; Cats, Annemieke; Boot, Henk; Jansen, Edwin Petrus Marianus; Verheij, Marcel

    2014-01-01

    Objective: This observational study compares the effect of different radiotherapy techniques on late nephrotoxicity after postoperative chemoradiotherapy for gastric cancer. Patients and methods: Dosimetric parameters were compared between AP–PA, 3D-conformal and IMRT techniques. Renal function was measured by 99m Tc-MAG-3 renography, glomerular filtration rate (GFR) and the development of hypertension. Mixed effects models were used to compare renal function over time. Results: Eighty-seven patients treated between 2002 and 2010 were included, AP–PA (n = 31), 3D-conformal (n = 25) and IMRT (n = 31), all 45 Gy in 25 fractions. Concurrent chemotherapy: 5FU/leucovorin (n = 4), capecitabine (n = 37), and capecitabine/cisplatin (n = 46). Median follow-up time was 4.7 years (range 0.2–8). With IMRT, the mean dose to the left kidney was significantly lower. Left kidney function decreased progressively in the total study population, however with IMRT this occurred at a lower rate. A dose–effect relationship was present between mean dose to the left kidney and the left kidney function. GFR decreased only moderately in time, which was not different between techniques. Six patients developed hypertension, of whom none in the IMRT group. Conclusions: This study confirms progressive late nephrotoxicity in patients treated with postoperative chemoradiotherapy by different techniques for gastric cancer. Nephrotoxicity was less severe with IMRT and should be considered the preferred technique

  7. IMRT limits nephrotoxicity after chemoradiotherapy for gastric cancer.

    Science.gov (United States)

    Trip, Anouk Kirsten; Nijkamp, Jasper; van Tinteren, Harm; Cats, Annemieke; Boot, Henk; Jansen, Edwin Petrus Marianus; Verheij, Marcel

    2014-08-01

    This observational study compares the effect of different radiotherapy techniques on late nephrotoxicity after postoperative chemoradiotherapy for gastric cancer. Dosimetric parameters were compared between AP-PA, 3D-conformal and IMRT techniques. Renal function was measured by (99m)Tc-MAG-3 renography, glomerular filtration rate (GFR) and the development of hypertension. Mixed effects models were used to compare renal function over time. Eighty-seven patients treated between 2002 and 2010 were included, AP-PA (n=31), 3D-conformal (n=25) and IMRT (n=31), all 45 Gy in 25 fractions. Concurrent chemotherapy: 5FU/leucovorin (n=4), capecitabine (n=37), and capecitabine/cisplatin (n=46). Median follow-up time was 4.7 years (range 0.2-8). With IMRT, the mean dose to the left kidney was significantly lower. Left kidney function decreased progressively in the total study population, however with IMRT this occurred at a lower rate. A dose-effect relationship was present between mean dose to the left kidney and the left kidney function. GFR decreased only moderately in time, which was not different between techniques. Six patients developed hypertension, of whom none in the IMRT group. This study confirms progressive late nephrotoxicity in patients treated with postoperative chemoradiotherapy by different techniques for gastric cancer. Nephrotoxicity was less severe with IMRT and should be considered the preferred technique. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Dose evaluation of TPS according to treatment sites in IMRT

    International Nuclear Information System (INIS)

    Kim, Jin Man; Kim, Jong Sik; Hong, Chae Seon; Park, Ju Young; Park, Su Yeon; Ju, Sang Gyu

    2013-01-01

    This study executed therapy plans on prostate cancer (homogeneous density area) and lung cancer (non-homogeneous density area) using radiation treatment planning systems such as Pinnacle 3 (version 9.2, Philips Medical Systems, USA) and Eclipse (version 10.0, Varian Medical Systems, USA) in order to quantify the difference between dose calculation according to density in IMRT. The subjects were prostate cancer patients (n=5) and lung cancer patients (n=5) who had therapies in our hospital. Identical constraints and optimization process according to the Protocol were administered on the subjects. For the therapy plan of prostate cancer patients, 10 MV and 7Beam were used and 2.5 Gy was prescribed in 28 fx to make 70 Gy in total. For lung cancer patients, 6 MV and 6Beam were used and 2 Gy was prescribed in 33 fx to make 66 Gy in total. Through two therapy planning systems, maximum dose, average dose, and minimum dose of OAR (Organ at Risk) of CTV, PTV and around tumor were investigated. In prostate cancer, both therapy planning systems showed within 2% change of dose of CTV and PTV and normal organs (Bladder, Both femur and Rectum out) near the tumor satisfied the dose constraints. In lung cancer, CTV and PTV showed less than 2% changes in dose and normal organs (Esophagus, Spinal cord and Both lungs) satisfied dose restrictions. However, the minimum dose of Eclipse therapy plan was 1.9% higher in CTV and 3.5% higher in PTV, and in case of both lungs there was 3.0% difference at V5 Gy. Each TPS according to the density satisfied dose limits of our hospital proving the clinical accuracy. It is considered more accurate and precise therapy plan can be made if studies on treatment planning for diverse parts and the application of such TPS are made

  9. Preliminary investigation of stereotactic body radiation therapy for medically inoperable stage I/II non-small cell lung cancer

    International Nuclear Information System (INIS)

    Guo Jindong; Lu Changxing; Wang Jiaming; Liu Jun; Li Hongxuan; Wang Changlu; Gao Lanting; Zhao Lei

    2011-01-01

    Objective: To evaluate the therapeutic efficacy and treatment-related toxicity of stereotactic body radiation therapy (SBRT) in patients with medically inoperable stage I/II non-small cell lung cancer (NSCLC). Methods: SBRT was applied to 30 patients, including clinically staged T 1 , T 2 (≤5 cm) or T 3 (chest wall primary tumors only), N 0 , M 0 ,biopsy-confirmed NSCLC. All patients were precluded from lobotomy because of physical condition or comorbidity. No patients developed tumors of any T-stage in the proximal zone. SBRT was performed with the total dose of 50 Gy to 70 Gy in 10 - 11 fractions during 12 - 15 days. prescription line was set onthe edge of the PTV. Results: The follow-up rate was 100%. The number of patients who completed the 1-, and 2-year follow-up were 15, and 10, respectively. All 30 patients completed therapy as planned. The complete response (CR), partial response (PR) and stable disease (SD) rates were 37%, 53% and 3%, respectively. With a median follow-up of 16 months (range, 4-36 months), Kaplan-Meier local control at 2 years was 94%. The 2-year overall survival was 84% and the 2-year cancer specific survival was 90%. Seven patients(23%) developed Grade 2 pneumonitis, no grade > 2 acute or late lung toxicity was observed. No one developed chest wall pain. Conclusions: It is feasible to deliver 50 Gy to 70 Gy of SBRT in 10 - 11 fractions for medically inoperable patients with stage I / II NSCLC. It was associated with low incidence of toxicities and provided sustained local tumor control.The preliminary investigation indicated the cancer specific survival probability of SBRT was high. It is necessary to perform similar investigation in a larger number of patients with long-term follow-up. (authors)

  10. Institutional Patient-specific IMRT QA Does Not Predict Unacceptable Plan Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Kry, Stephen F., E-mail: sfkry@mdanderson.org [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Molineu, Andrea [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kerns, James R.; Faught, Austin M.; Huang, Jessie Y.; Pulliam, Kiley B.; Tonigan, Jackie [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Health Science Center Houston, Graduate School of Biomedical Sciences, Houston, Texas (United States); Alvarez, Paola [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Stingo, Francesco [The University of Texas Health Science Center Houston, Graduate School of Biomedical Sciences, Houston, Texas (United States); Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Followill, David S. [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Health Science Center Houston, Graduate School of Biomedical Sciences, Houston, Texas (United States)

    2014-12-01

    Purpose: To determine whether in-house patient-specific intensity modulated radiation therapy quality assurance (IMRT QA) results predict Imaging and Radiation Oncology Core (IROC)-Houston phantom results. Methods and Materials: IROC Houston's IMRT head and neck phantoms have been irradiated by numerous institutions as part of clinical trial credentialing. We retrospectively compared these phantom results with those of in-house IMRT QA (following the institution's clinical process) for 855 irradiations performed between 2003 and 2013. The sensitivity and specificity of IMRT QA to detect unacceptable or acceptable plans were determined relative to the IROC Houston phantom results. Additional analyses evaluated specific IMRT QA dosimeters and analysis methods. Results: IMRT QA universally showed poor sensitivity relative to the head and neck phantom, that is, poor ability to predict a failing IROC Houston phantom result. Depending on how the IMRT QA results were interpreted, overall sensitivity ranged from 2% to 18%. For different IMRT QA methods, sensitivity ranged from 3% to 54%. Although the observed sensitivity was particularly poor at clinical thresholds (eg 3% dose difference or 90% of pixels passing gamma), receiver operator characteristic analysis indicated that no threshold showed good sensitivity and specificity for the devices evaluated. Conclusions: IMRT QA is not a reasonable replacement for a credentialing phantom. Moreover, the particularly poor agreement between IMRT QA and the IROC Houston phantoms highlights surprising inconsistency in the QA process.

  11. Institutional Patient-specific IMRT QA Does Not Predict Unacceptable Plan Delivery

    International Nuclear Information System (INIS)

    Kry, Stephen F.; Molineu, Andrea; Kerns, James R.; Faught, Austin M.; Huang, Jessie Y.; Pulliam, Kiley B.; Tonigan, Jackie; Alvarez, Paola; Stingo, Francesco; Followill, David S.

    2014-01-01

    Purpose: To determine whether in-house patient-specific intensity modulated radiation therapy quality assurance (IMRT QA) results predict Imaging and Radiation Oncology Core (IROC)-Houston phantom results. Methods and Materials: IROC Houston's IMRT head and neck phantoms have been irradiated by numerous institutions as part of clinical trial credentialing. We retrospectively compared these phantom results with those of in-house IMRT QA (following the institution's clinical process) for 855 irradiations performed between 2003 and 2013. The sensitivity and specificity of IMRT QA to detect unacceptable or acceptable plans were determined relative to the IROC Houston phantom results. Additional analyses evaluated specific IMRT QA dosimeters and analysis methods. Results: IMRT QA universally showed poor sensitivity relative to the head and neck phantom, that is, poor ability to predict a failing IROC Houston phantom result. Depending on how the IMRT QA results were interpreted, overall sensitivity ranged from 2% to 18%. For different IMRT QA methods, sensitivity ranged from 3% to 54%. Although the observed sensitivity was particularly poor at clinical thresholds (eg 3% dose difference or 90% of pixels passing gamma), receiver operator characteristic analysis indicated that no threshold showed good sensitivity and specificity for the devices evaluated. Conclusions: IMRT QA is not a reasonable replacement for a credentialing phantom. Moreover, the particularly poor agreement between IMRT QA and the IROC Houston phantoms highlights surprising inconsistency in the QA process

  12. Dosimetric and motion analysis of margin-intensive therapy by stereotactic ablative radiotherapy for resectable pancreatic cancer

    Directory of Open Access Journals (Sweden)

    Heinzerling John H

    2011-10-01

    Full Text Available Abstract Background The retroperitoneal margin is a common site of positive surgical margins in patients with resectable pancreatic cancer. Preoperative margin-intensive therapy (MIT involves delivery of a single high dose of ablative radiotherapy (30 Gy focused on this surgically inaccessible margin, utilizing stereotactic techniques in an effort to reduce local failure following surgery. In this study, we investigated the motion of regional organs at risk (OAR utilizing 4DCT, evaluated the dosimetric effects of abdominal compression (AC to reduce regional motion, and compared various planning techniques to optimize MIT. Methods 10 patients were evaluated with 4DCT scans. All 10 patients had scans using AC and seven of the 10 patients had scans both with and without AC. The peak respiratory abdominal organ and major vessel centroid excursion was measured. A "sub-GTV" region was defined by a radiation oncologist and surgical oncologist encompassing the retroperitoneal margin typically lateral and posterior to the superior mesenteric artery (SMA, and a 3-5 mm margin was added to constitute the PTV. Identical 3D non-coplanar SABR (3DSABR plans were designed for the average compression and non-compression scans. Compression scans were planned with 3DSABR, coplanar IMRT (IMRT, and Cyberknife (CK planning techniques. Dose volume analysis was undertaken for various endpoints, comparing OAR doses with and without AC and for different planning methods. Results The mean PTV size was 20.2 cm3. Regional vessel motion of the SMA, celiac trunk, and renal vessels was small ( 5 mm, so AC has been used in all patients enrolled thus far. AC did not significantly increase OAR dose including the stomach and traverse colon. There were several statistically significant differences in the doses to OARs as a function of the type of planning modality used. Conclusions AC does not significantly reduce the limited motion of structures in close proximity to the MIT target

  13. Automated IMRT planning with regional optimization using planning scripts.

    Science.gov (United States)

    Xhaferllari, Ilma; Wong, Eugene; Bzdusek, Karl; Lock, Michael; Chen, Jeff

    2013-01-07

    Intensity-modulated radiation therapy (IMRT) has become a standard technique in radiation therapy for treating different types of cancers. Various class solutions have been developed for simple cases (e.g., localized prostate, whole breast) to generate IMRT plans efficiently. However, for more complex cases (e.g., head and neck, pelvic nodes), it can be time-consuming for a planner to generate optimized IMRT plans. To generate optimal plans in these more complex cases which generally have multiple target volumes and organs at risk, it is often required to have additional IMRT optimization structures such as dose limiting ring structures, adjust beam geometry, select inverse planning objectives and associated weights, and additional IMRT objectives to reduce cold and hot spots in the dose distribution. These parameters are generally manually adjusted with a repeated trial and error approach during the optimization process. To improve IMRT planning efficiency in these more complex cases, an iterative method that incorporates some of these adjustment processes automatically in a planning script is designed, implemented, and validated. In particular, regional optimization has been implemented in an iterative way to reduce various hot or cold spots during the optimization process that begins with defining and automatic segmentation of hot and cold spots, introducing new objectives and their relative weights into inverse planning, and turn this into an iterative process with termination criteria. The method has been applied to three clinical sites: prostate with pelvic nodes, head and neck, and anal canal cancers, and has shown to reduce IMRT planning time significantly for clinical applications with improved plan quality. The IMRT planning scripts have been used for more than 500 clinical cases.

  14. Phantoms for IMRT dose distribution measurement and treatment verification

    International Nuclear Information System (INIS)

    Low, Daniel A.; Gerber, Russell L.; Mutic, Sasa; Purdy, James A.

    1998-01-01

    Background: The verification of intensity-modulated radiation therapy (IMRT) patient treatment dose distributions is currently based on custom-built or modified dose measurement phantoms. The only commercially available IMRT treatment planning and delivery system (Peacock, NOMOS Corp.) is supplied with a film phantom that allows accurate spatial localization of the dose distribution using radiographic film. However, measurements using other dosimeters are necessary for the thorough verification of IMRT. Methods: We have developed a phantom to enable dose measurements using a cylindrical ionization chamber and the localization of prescription isodose curves using a matrix of thermoluminescent dosimetry (TLD) chips. The external phantom cross-section is identical to that of the commercial phantom, to allow direct comparisons of measurements. A supplementary phantom has been fabricated to verify the IMRT dose distributions for pelvis treatments. Results: To date, this phantom has been used for the verification of IMRT dose distributions for head and neck and prostate cancer treatments. Designs are also presented for a phantom insert to be used with polymerizing gels (e.g., BANG-2) to obtain volumetric dose distribution measurements. Conclusion: The phantoms have proven useful in the quantitative evaluation of IMRT treatments

  15. Results of patient specific quality assurance for patients undergoing stereotactic ablative radiotherapy for lung lesions

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Clements, Natalie; Cramb, Jim; Wanigaratne, Derrick M.; Chesson, Brent; Aarons, Yolanda; Siva, Shankar; Ball, David; Kron, Tomas

    2014-01-01

    Hypofractionated image guided radiotherapy of extracranial targets has become increasingly popular as a treatment modality for inoperable patients with one or more small lesions, often referred to as stereotactic ablative body radiotherapy (SABR). This report details the results of the physical quality assurance (QA) program used for the first 33 lung cancer SABR radiotherapy 3D conformal treatment plans in our centre. SABR involves one or few fractions of high radiation dose delivered in many small fields or arcs with tight margins to mobile targets often delivered through heterogeneous media with non-coplanar beams. We have conducted patient-specific QA similar to the more common intensity modulated radiotherapy QA with particular reference to motion management. Individual patient QA was performed in a Perspex phantom using point dose verification with an ionisation chamber and radiochromic film for verification of the dose distribution both with static and moving detectors to verify motion management strategies. While individual beams could vary by up to 7 %, the total dose in the target was found to be within ±2 % of the prescribed dose for all 33 plans. Film measurements showed qualitative and quantitative agreement between planned and measured isodose line shapes and dimensions. The QA process highlighted the need to account for couch transmission and demonstrated that the ITV construction was appropriate for the treatment technique used. QA is essential for complex radiotherapy deliveries such as SABR. We found individual patient QA helpful in setting up the technique and understanding potential weaknesses in SABR workflow, thus providing confidence in SABR delivery.

  16. SU-E-T-428: Dosimetric Impact of Multileaf Collimator Leaf Width On Single and multiple Isocenter Stereotactic IMRT Treatment Plans for multiple Brain Tumors

    International Nuclear Information System (INIS)

    Giem, J; Algan, O; Ahmad, S; Ali, I; Young, J; Hossain, S

    2014-01-01

    Purpose: To assess the impacts that multileaf collimator (MLC) leaf width has on the dose conformity and normal brain tissue doses of single and multiple isocenter stereotactic IMRT (SRT) plans for multiple intracranial tumors. Methods: Fourteen patients with 2–3 targets were studied retrospectively. Patients treated with multiple isocenter treatment plans using 9 to 12 non-coplanar beams per lesion underwent repeat planning using single isocenter and 10 to 12 non-coplanar beams with 2.5mm, 3mm and 5mm MLC leaf widths. Brainlab iPlan treatment planning system for delivery with the 2.5mm MLC served as reference. Identical contour sets and dose-volume constraints were applied. The prescribed dose to each target was 25 Gy to be delivered over 5 fractions with a minimum of 99% dose to cover ≥ 95% of the target volume. Results: The lesions and normal brains ranged in size from 0.11 to 51.67cc (median, 2.75cc) and 1090 to 1641cc (median, 1401cc), respectively. The Paddick conformity index for single and multiple isocenter (2.5mm vs. 3mm and 5mm MLCs) was (0.79±0.08 vs. 0.79±0.07 and 0.77±0.08) and (0.79±0.09 vs. 0.77±0.09 and 0.76±0.08), respectively. The average normal brain volumes receiving 15 Gy for single and multiple isocenter (2.5mm vs. 3mm and 5mm MLCs) were (3.65% vs. 3.95% and 4.09%) and (2.89% vs. 2.91% and 2.92%), respectively. Conclusion: The average dose conformity observed for the different leaf width for single and multiple isocenter plans were similar, throughout. However, the average normal brain volumes receiving 2.5 to 15 Gy were consistently lower for the 2.5mm MLC leaf width, especially for single isocenter plans. The clinical consequences of these integral normal brain tissue doses are still unknown, but employing the use of the 2.5mm MLC option is desirable at sparing normal brain tissue for both single and multiple isocenter cases

  17. Phase II study on stereotactic body radiotherapy of colorectal metastases

    DEFF Research Database (Denmark)

    Høyer, Morten; Roed, Henrik; Traberg Hansen, Anders

    2006-01-01

    Surgical resection provides long term survival in approximately 30% of patients with colorectal carcinoma (CRC) liver metastases. However, only a limited number of patients with CRC-metastases are amendable for surgery. We have tested the effect of stereotactic body radiotherapy (SBRT) in the tre......Surgical resection provides long term survival in approximately 30% of patients with colorectal carcinoma (CRC) liver metastases. However, only a limited number of patients with CRC-metastases are amendable for surgery. We have tested the effect of stereotactic body radiotherapy (SBRT......) in the treatment of inoperable patients with CRC-metastases. Sixty-four patients with a total number of 141 CRC-metastases in the liver (n = 44), lung (n = 12), lymph nodes (n = 3), suprarenal gland (n = 1) or two organs (n = 4) were treated with SBRT with a central dose of 15 Gy x 3 within 5-8 days. Median follow...... due to hepatic failure, one patient was operated for a colonic perforation and two patients were conservatively treated for duodenal ulcerations. Beside these, only moderate toxicities such as nausea, diarrhoea and skin reactions were observed. SBRT in patients with inoperable CRC-metastases resulted...

  18. Positioning accuracy for lung stereotactic body radiotherapy patients determined by on-treatment cone-beam CT imaging

    Science.gov (United States)

    Richmond, N D; Pilling, K E; Peedell, C; Shakespeare, D; Walker, C P

    2012-01-01

    Stereotactic body radiotherapy for early stage non-small cell lung cancer is an emerging treatment option in the UK. Since relatively few high-dose ablative fractions are delivered to a small target volume, the consequences of a geometric miss are potentially severe. This paper presents the results of treatment delivery set-up data collected using Elekta Synergy (Elekta, Crawley, UK) cone-beam CT imaging for 17 patients immobilised using the Bodyfix system (Medical Intelligence, Schwabmuenchen, Germany). Images were acquired on the linear accelerator at initial patient treatment set-up, following any position correction adjustments, and post-treatment. These were matched to the localisation CT scan using the Elekta XVI software. In total, 71 fractions were analysed for patient set-up errors. The mean vector error at initial set-up was calculated as 5.3±2.7 mm, which was significantly reduced to 1.4±0.7 mm following image guided correction. Post-treatment the corresponding value was 2.1±1.2 mm. The use of the Bodyfix abdominal compression plate on 5 patients to reduce the range of tumour excursion during respiration produced mean longitudinal set-up corrections of −4.4±4.5 mm compared with −0.7±2.6 mm without compression for the remaining 12 patients. The use of abdominal compression led to a greater variation in set-up errors and a shift in the mean value. PMID:22665927

  19. Lhermitte's Sign Developing after IMRT for Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Dong C. Lim

    2010-01-01

    Full Text Available Background. Lhermitte's sign (LS is a benign form of myelopathy with neck flexion producing an unpleasant electric-shock sensation radiating down the extremities. Although rare, it can occur after head and neck radiotherapy. Results. We report a case of Lhermitte's developing after curative intensity-modulated radiotherapy (IMRT for a patient with locoregionally advanced oropharyngeal cancer. IMRT delivers a conformal dose of radiation in head and neck cancer resulting in a gradient of radiation dose throughout the spinal cord. Using IMRT, more dose is delivered to the anterior spinal cord than the posterior cord. Conclusions. Lhermitte's sign can develop after IMRT for head and neck cancer. We propose an anterior spinal cord structure, the spinothalamic tract to be the target of IMRT-caused LS.

  20. A randomised phase II trial of Stereotactic Ablative Fractionated radiotherapy versus Radiosurgery for Oligometastatic Neoplasia to the lung (TROG 13.01 SAFRON II)

    International Nuclear Information System (INIS)

    Siva, Shankar; Kron, Tomas; Bressel, Mathias; Haas, Marion; Mai, Tao; Vinod, Shalini; Sasso, Giuseppe; Wong, Wenchang; Le, Hien; Eade, Thomas; Hardcastle, Nicholas; Chesson, Brent; Pham, Daniel; Høyer, Morten; Montgomery, Rebecca; Ball, David

    2016-01-01

    Stereotactic ablative body radiotherapy (SABR) is emerging as a non-invasive method for precision irradiation of lung tumours. However, the ideal dose/fractionation schedule is not yet known. The primary purpose of this study is to assess safety and efficacy profile of single and multi-fraction SABR in the context of pulmonary oligometastases. The TROG 13.01/ALTG 13.001 clinical trial is a multicentre unblinded randomised phase II study. Eligible patients have up to three metastases to the lung from any non-haematological malignancy, each < 5 cm in size, non-central targets, and have all primary and extrathoracic disease controlled with local therapies. Patients are randomised 1:1 to a single fraction of 28Gy versus 48Gy in four fractions of SABR. The primary objective is to assess the safety of each treatment arm, with secondary objectives including assessment of quality of life, local efficacy, resource use and costs, overall and disease free survival and time to distant failure. Outcomes will be stratified by number of metastases and origin of the primary disease (colorectal versus non-colorectal primary). Planned substudies include an assessment of the impact of online e-Learning platforms for lung SABR and assessment of the effect of SABR fractionation on the immune responses. A total of 84 patients are required to complete the study. Fractionation schedules have not yet been investigated in a randomised fashion in the setting of oligometastatic disease. Assuming the likelihood of similar clinical efficacy in both arms, the present study design allows for exploration of the hypothesis that cost implications of managing potentially increased toxicities from single fraction SABR will be outweighed by costs associated with delivering multiple-fraction SABR

  1. Intensity modulated radiotherapy (IMRT) with compensators

    International Nuclear Information System (INIS)

    Salz, H.; Wiezorek, T.; Scheithauer, M.; Kleen, W.; Schwedas, M.; Wendt, T.G.

    2002-01-01

    The irradiation with intensity-modulated fields is possible with static as well as dynamic methods. In our university hospital, the intensity-modulated radiotherapy (IMRT) with compensators was prepared and used for the first time for patient irradiation in July 2001. The compensators consist of a mixture of tin granulate and wax, which is filled in a milled negative mould. The treatment planning is performed with Helax-TMS (MDS Nordion). An additional software is used for editing the modulation matrix ('Modifix'). Before irradiation of the first patient, extensive measurements have been carried out in terms of quality assurance of treatment planning and production of compensators. The results of the verification measurements have shown that IMRT with compensators possesses high spatial and dosimetric exactness. The calculated dose distributions are applied correctly. The accuracy of the calculated monitor units is normally better than 3%; in small volumes, further dosimetric inaccuracies between calculated and measured dose distributions are mostly less than 3%. Therefore, the compensators contribute to the achievement of high-level IMRT even when apparatuses without MLC are used. This paper describes the use of the IMRT with compensators, presents the limits of this technology, and discusses the first practical experiences. (orig.) [de

  2. A study of different dose calculation methods and the impact on the dose evaluation protocol in lung stereotactic radiation therapy

    International Nuclear Information System (INIS)

    Takada, Takahiro; Furuya, Tomohisa; Ozawa, Shuichi; Ito, Kana; Kurokawa, Chie; Karasawa, Kumiko; Miura, Kohei

    2008-01-01

    AAA (analytical anisotropic algorithm) dose calculation, which shows a better performance for heterogeneity correction, was tested for lung stereotactic radiation therapy (SBRT) in comparison to conventional PBC (pencil beam convolution method) to evaluate its impact on tumor dose parameters. Eleven lung SBRT patients who were treated with photon 4 MV beams in our department between April 2003 and February 2007 were reviewed. Clinical target volume (CTV) was delineated including the spicula region on planning CT images. Planning target volume (PTV) was defined by adding the internal target volume (ITV) and set-up margin (SM) of 5 mm from CTV, and then an multileaf collimator (MLC) penumbra margin of another 5 mm was also added. Six-port non-coplanar beams were employed, and a total prescribed dose of 48 Gy was defined at the isocenter point with four fractions. The entire treatment for an individual patient was completed within 8 days. Under the same prescribed dose, calculated dose distribution, dose volume histogram (DVH), and tumor dose parameters were compared between two dose calculation methods. In addition, the fractionated prescription dose was repeatedly scaled until the monitor units (MUs) calculated by AAA reached a level of MUs nearly identical to those achieved by PBC. AAA resulted in significantly less D95 (irradiation dose that included 95% volume of PTV) and minimal dose in PTV compared to PBC. After rescaling of each MU for each beam in the AAA plan, there was no revision of the isocenter of the prescribed dose required. However, when the PTV volume was less than 20 cc, a 4% lower prescription resulted in nearly identical MUs between AAA and PBC. The prescribed dose in AAA should be the same as that in PBC, if the dose is administered at the isocenter point. However, planners should compare DVHs and dose distributions between AAA and PBC for a small lung tumor with a PTV volume less than approximately 20 cc. (author)

  3. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  4. The effect of concomitant chemotherapy on parotid gland function following head and neck IMRT

    International Nuclear Information System (INIS)

    Miah, Aisha B.; Gulliford, Sarah L.; Bhide, Shreerang A.; Zaidi, Shane H.; Newbold, Kate L.; Harrington, Kevin J.; Nutting, Christopher M.

    2013-01-01

    Purpose: To determine whether concomitant chemotherapy increases the incidence of high grade xerostomia following parotid-sparing intensity-modulated radiotherapy (IMRT) in patients with locally advanced head and neck squamous cell cancer. Materials and methods: The incidence of high grade (⩾G2) acute (CTCAEv3.0) and late (LENTSOMA and RTOG) xerostomia was compared between patients treated with either IMRT or concomitant chemo-IMRT (c-IMRT) in 2 prospective studies. Parotid gland mean tolerance doses (D 50 ) were reported using non-linear logistic regression analysis. Results: Thirty-six patients received IMRT alone and 60 patients received c-IMRT. Patients received 65 Gy in 30 daily fractions to the primary site and involved nodal groups and 54 Gy in 30 fractions to elective nodal groups, mean doses to the parotid glands were comparable. Concomitant cisplatin 100 mg/m 2 was administered on days 1 and 29 of IMRT. The incidence of ⩾G2 subjective xerostomia was similar in both groups; acute-64.7% (IMRT) versus 60.3% (c-IMRT), p = 0.83; late-43% (IMRT) versus 34% (c-IMRT), p = 0.51. Recovery of parotid salivary flow at 1 year was higher with IMRT (64% vs 50%), but not statistically significant (p = 0.15). D 50 for absence of parotid saliva flow at 1 year was 23.2 Gy (95% CI: 17.7–28.7) for IMRT and 21.1 Gy (11.8–30.3) for c-IMRT. Conclusion: Concomitant c-IMRT does not increase the incidence of acute or late xerostomia relative to IMRT alone

  5. The effect of concomitant chemotherapy on parotid gland function following head and neck IMRT.

    Science.gov (United States)

    Miah, Aisha B; Gulliford, Sarah L; Bhide, Shreerang A; Zaidi, Shane H; Newbold, Kate L; Harrington, Kevin J; Nutting, Christopher M

    2013-03-01

    To determine whether concomitant chemotherapy increases the incidence of high grade xerostomia following parotid-sparing intensity-modulated radiotherapy (IMRT) in patients with locally advanced head and neck squamous cell cancer. The incidence of high grade (≥G2) acute (CTCAEv3.0) and late (LENTSOMA and RTOG) xerostomia was compared between patients treated with either IMRT or concomitant chemo-IMRT (c-IMRT) in 2 prospective studies. Parotid gland mean tolerance doses (D₅₀) were reported using non-linear logistic regression analysis. Thirty-six patients received IMRT alone and 60 patients received c-IMRT. Patients received 65 Gy in 30 daily fractions to the primary site and involved nodal groups and 54 Gy in 30 fractions to elective nodal groups, mean doses to the parotid glands were comparable. Concomitant cisplatin 100mg/m(2) was administered on days 1 and 29 of IMRT. The incidence of ≥G2 subjective xerostomia was similar in both groups; acute-64.7% (IMRT) versus 60.3% (c-IMRT), p=0.83; late-43% (IMRT) versus 34% (c-IMRT), p=0.51. Recovery of parotid salivary flow at 1 year was higher with IMRT (64% vs 50%), but not statistically significant (p=0.15). D₅₀ for absence of parotid saliva flow at 1 year was 23.2 Gy (95% CI: 17.7-28.7) for IMRT and 21.1 Gy (11.8-30.3) for c-IMRT. Concomitant c-IMRT does not increase the incidence of acute or late xerostomia relative to IMRT alone. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Stereotactic body radiotherapy and treatment at a high volume facility is associated with improved survival in patients with inoperable stage I non-small cell lung cancer

    International Nuclear Information System (INIS)

    Koshy, Matthew; Malik, Renuka; Mahmood, Usama; Husain, Zain; Sher, David J.

    2015-01-01

    Background: This study examined the comparative effectiveness of no treatment (NoTx), conventional fractionated radiotherapy (ConvRT), and stereotactic body radiotherapy (SBRT) in patients with inoperable stage I non-small cell lung cancer. This population based cohort also allowed us to examine what facility level characteristics contributed to improved outcomes. Methods: We included patients in the National Cancer Database from 2003 to 2006 with T1-T2N0M0 inoperable lung cancer (n = 13,036). Overall survival (OS) was estimated using Kaplan–Meier methods and Cox proportional hazard regression. Results: The median follow up was 68 months (interquartile range: 35–83 months) in surviving patients. Among the cohort, 52% received NoTx, 41% received ConvRT and 6% received SBRT. The 3-year OS was 28% for NoTx, 36% for ConvRT radiotherapy, and 48% for the SBRT cohort (p < 0.0001). On multivariate analysis, the hazard ratio for SBRT and ConvRT were 0.67 and 0.77, respectively, as compared to NoTx (1.0 ref) (p < 0.0001). Patients treated at a high volume facility vs. low volume facility had a hazard ratio of 0.94 vs. 1.0 (p = 0.01). Conclusions: Patients with early stage inoperable lung cancer treated with SBRT and at a high volume facility had a survival benefit compared to patients treated with ConvRT or NoTx or to those treated at a low volume facility

  7. Effect of immobilization and performance status on intrafraction motion for stereotactic lung radiotherapy: analysis of 133 patients.

    Science.gov (United States)

    Li, Winnie; Purdie, Thomas G; Taremi, Mojgan; Fung, Sharon; Brade, Anthony; Cho, B C John; Hope, Andrew; Sun, Alexander; Jaffray, David A; Bezjak, Andrea; Bissonnette, Jean-Pierre

    2011-12-01

    To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board-approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic (Σ) and random (σ) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n=75], evacuated cushion plus abdominal compression [n=33], or chest board [n=25]) and by patients' Eastern Cooperative Oncology Group performance status (PS): 0 (n=31), 1 (n=70), or 2 (n=32). Using CBCT internal target volume was matched within ±3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (pPositional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p=0.04). Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization method or PS. A 5-mm setup margin suffices to address intrafraction motion. This setup margin may be further reduced by strategies such as

  8. Effect of Immobilization and Performance Status on Intrafraction Motion for Stereotactic Lung Radiotherapy: Analysis of 133 Patients

    International Nuclear Information System (INIS)

    Li, Winnie; Purdie, Thomas G.; Taremi, Mojgan; Fung, Sharon; Brade, Anthony; Cho, B.C. John; Hope, Andrew; Sun, Alexander; Jaffray, David A.; Bezjak, Andrea; Bissonnette, Jean-Pierre

    2011-01-01

    Purpose: To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Methods and Materials: Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board–approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic (Σ) and random (σ) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n = 75], evacuated cushion plus abdominal compression [n = 33], or chest board [n = 25]) and by patients’ Eastern Cooperative Oncology Group performance status (PS): 0 (n = 31), 1 (n = 70), or 2 (n = 32). Results: Using CBCT internal target volume was matched within ±3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (<1 mm) in the cranial–caudal direction of target position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (p < 0.01). Positional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p = 0.04). Conclusions: Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization

  9. Conformal intensity-modulated radiotherapy (IMRT) delivered by robotic linac - testing IMRT to the limit?

    International Nuclear Information System (INIS)

    Webb, S.

    1999-01-01

    In this paper it is proposed that intensity-modulated radiotherapy (IMRT) could be delivered optimally by a short-length linac mounted on a robotic arm. The robot would allow the linac to 'plant' narrow pencils of photon radiation with any orientation (excluding zones within which the linac and couch might collide) relative to the planning target volume (PTV). The treatment is specified by the trajectory of the robot and by the number of monitor units (MUs) delivered at each robotic orientation. An inverse-planning method to determine the optimum robotic trajectory is presented. It is shown that for complex PTVs, specifically those with concavities in their outline, the conformality of the treatment is improved by the use of a complex trajectory in comparison with a less complex constrained trajectory and this improvement is quantified. It is concluded that robotic linac delivery would lead to a great flexibility in those IMRT treatments requiring very complicated dose distributions with complex 3D shapes. However, even using very fast computers, the goal of determining whether robotic linac delivery is the ultimate IMRT cannot be conclusively reached at present. (author)

  10. Clinical outcome of stereotactic body radiotherapy for primary and oligometastatic lung tumors: a single institutional study with almost uniform dose with different five treatment schedules

    International Nuclear Information System (INIS)

    Aoki, Masahiko; Hatayama, Yoshiomi; Kawaguchi, Hideo; Hirose, Katsumi; Sato, Mariko; Akimoto, Hiroyoshi; Fujioka, Ichitaro; Ono, Shuichi; Tsushima, Eiki; Takai, Yoshihiro

    2016-01-01

    To evaluate clinical outcomes of stereotactic body radiotherapy (SBRT) for localized primary and oligometastatic lung tumors by assessing efficacy and safety of 5 regimens of varying fraction size and number. One-hundred patients with primary lung cancer (n = 69) or oligometastatic lung tumors (n = 31), who underwent SBRT between May 2003 and August 2010, were included. The median age was 75 years (range, 45–88). Of them, 98 were judged to have medically inoperable disease, predominantly due to chronic illness or advanced age. SBRT was performed using 3 coplanar and 3 non-coplanar fixed beams with a standard linear accelerator. Fraction sizes were escalated by 1 Gy, and number of fractions given was decreased by 1 for every 20 included patients. Total target doses were between 50 and 56 Gy, administered as 5–9 fractions. The prescribed dose was defined at the isocenter, and median overall treatment duration was 10 days (range, 5–22). The median follow-up was 51.1 months for survivors. The 3-year local recurrence rates for primary lung cancer and oligometastasis was 6 % and 3 %, respectively. The 3-year local recurrence rates for tumor sizes ≤3 cm and >3 cm were 3 % and 14 %, respectively (p = 0.124). Additionally, other factors (fraction size, total target dose, and BED 10 ) were not significant predictors of local control. Radiation pneumonia (≥ grade 2) was observed in 2 patients. Radiation-induced rib fractures were observed in 22 patients. Other late adverse events of greater than grade 2 were not observed. Within this dataset, we did not observe a dose response in BED 10 values between 86.4 and 102.6 Gy. SBRT with doses between 50 and 56 Gy, administered over 5–9 fractions achieved acceptable tumor control without severe complications

  11. SU-F-T-256: 4D IMRT Planning Using An Early Prototype GPU-Enabled Eclipse Workstation

    Energy Technology Data Exchange (ETDEWEB)

    Hagan, A; Modiri, A; Sawant, A [University of Maryland in Baltimore, Baltimore, MD (United States); Svatos, M [Varian Medical Systems, Palo Alto, CA (United States)

    2016-06-15

    Purpose: True 4D IMRT planning, based on simultaneous spatiotemporal optimization has been shown to significantly improve plan quality in lung radiotherapy. However, the high computational complexity associated with such planning represents a significant barrier to widespread clinical deployment. We introduce an early prototype GPU-enabled Eclipse workstation for inverse planning. To our knowledge, this is the first GPUintegrated Eclipse system demonstrating the potential for clinical translation of GPU computing on a major commercially-available TPS. Methods: The prototype system comprised of four NVIDIA Tesla K80 GPUs, with a maximum processing capability of 8.5 Tflops per K80 card. The system architecture consisted of three key modules: (i) a GPU-based inverse planning module using a highly-parallelizable, swarm intelligence-based global optimization algorithm, (ii) a GPU-based open-source b-spline deformable image registration module, Elastix, and (iii) a CUDA-based data management module. For evaluation, aperture fluence weights in an IMRT plan were optimized over 9 beams,166 apertures and 10 respiratory phases (14940 variables) for a lung cancer case (GTV = 95 cc, right lower lobe, 15 mm cranio-caudal motion). Sensitivity of the planning time and memory expense to parameter variations was quantified. Results: GPU-based inverse planning was significantly accelerated compared to its CPU counterpart (36 vs 488 min, for 10 phases, 10 search agents and 10 iterations). The optimized IMRT plan significantly improved OAR sparing compared to the original internal target volume (ITV)-based clinical plan, while maintaining prescribed tumor coverage. The dose-sparing improvements were: Esophagus Dmax 50%, Heart Dmax 42% and Spinal cord Dmax 25%. Conclusion: Our early prototype system demonstrates that through massive parallelization, computationally intense tasks such as 4D treatment planning can be accomplished in clinically feasible timeframes. With further

  12. SU-F-T-256: 4D IMRT Planning Using An Early Prototype GPU-Enabled Eclipse Workstation

    International Nuclear Information System (INIS)

    Hagan, A; Modiri, A; Sawant, A; Svatos, M

    2016-01-01

    Purpose: True 4D IMRT planning, based on simultaneous spatiotemporal optimization has been shown to significantly improve plan quality in lung radiotherapy. However, the high computational complexity associated with such planning represents a significant barrier to widespread clinical deployment. We introduce an early prototype GPU-enabled Eclipse workstation for inverse planning. To our knowledge, this is the first GPUintegrated Eclipse system demonstrating the potential for clinical translation of GPU computing on a major commercially-available TPS. Methods: The prototype system comprised of four NVIDIA Tesla K80 GPUs, with a maximum processing capability of 8.5 Tflops per K80 card. The system architecture consisted of three key modules: (i) a GPU-based inverse planning module using a highly-parallelizable, swarm intelligence-based global optimization algorithm, (ii) a GPU-based open-source b-spline deformable image registration module, Elastix, and (iii) a CUDA-based data management module. For evaluation, aperture fluence weights in an IMRT plan were optimized over 9 beams,166 apertures and 10 respiratory phases (14940 variables) for a lung cancer case (GTV = 95 cc, right lower lobe, 15 mm cranio-caudal motion). Sensitivity of the planning time and memory expense to parameter variations was quantified. Results: GPU-based inverse planning was significantly accelerated compared to its CPU counterpart (36 vs 488 min, for 10 phases, 10 search agents and 10 iterations). The optimized IMRT plan significantly improved OAR sparing compared to the original internal target volume (ITV)-based clinical plan, while maintaining prescribed tumor coverage. The dose-sparing improvements were: Esophagus Dmax 50%, Heart Dmax 42% and Spinal cord Dmax 25%. Conclusion: Our early prototype system demonstrates that through massive parallelization, computationally intense tasks such as 4D treatment planning can be accomplished in clinically feasible timeframes. With further

  13. Quantification of incidental mediastinal and hilar irradiation delivered during definitive stereotactic body radiation therapy for peripheral non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Kate L.; Gomez, Jorge; Nazareth, Daryl P.; Warren, Graham W. [Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY (United States); Singh, Anurag K., E-mail: anurag.singh@roswellpark.org [Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY (United States)

    2012-07-01

    To determine the amount of incidental radiation dose received by the mediastinal and hilar nodes for patients with non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy (SBRT). Fifty consecutive patients with NSCLC, treated using an SBRT technique, were identified. Of these patients, 38 had a prescription dose of 60 Gy in 20-Gy fractions and were eligible for analysis. For each patient, ipsilateral upper (level 2) and lower (level 4) paratracheal, and hilar (level 10) nodal regions were contoured on the planning computed tomography (CT) images. Using the clinical treatment plan, dose and volume calculations were performed retrospectively for each nodal region. SBRT to upper lobe tumors resulted in an average total ipsilateral mean dose of between 5.2 and 7.8 Gy for the most proximal paratracheal nodal stations (2R and 4R for right upper lobe lesions, 2L and 4L for left upper lobe lesions). SBRT to lower lobe tumors resulted in an average total ipsilateral mean dose of between 15.6 and 21.5 Gy for the most proximal hilar nodal stations (10R for right lower lobe lesions, 10 l for left lower lobe lesions). Doses to more distal nodes were substantially lower than 5 Gy. The often substantial incidental irradiation, delivered during SBRT for peripheral NSCLC of the lower lobes to the most proximal hilar lymph nodes may be therapeutic for low-volume, subclinical nodal disease. Treatment of peripheral upper lobe lung tumors delivers less incidental irradiation to the paratracheal lymph nodes with lower likelihood of therapeutic benefit.

  14. Quantification of incidental mediastinal and hilar irradiation delivered during definitive stereotactic body radiation therapy for peripheral non–small cell lung cancer

    International Nuclear Information System (INIS)

    Martin, Kate L.; Gomez, Jorge; Nazareth, Daryl P.; Warren, Graham W.; Singh, Anurag K.

    2012-01-01

    To determine the amount of incidental radiation dose received by the mediastinal and hilar nodes for patients with non–small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy (SBRT). Fifty consecutive patients with NSCLC, treated using an SBRT technique, were identified. Of these patients, 38 had a prescription dose of 60 Gy in 20-Gy fractions and were eligible for analysis. For each patient, ipsilateral upper (level 2) and lower (level 4) paratracheal, and hilar (level 10) nodal regions were contoured on the planning computed tomography (CT) images. Using the clinical treatment plan, dose and volume calculations were performed retrospectively for each nodal region. SBRT to upper lobe tumors resulted in an average total ipsilateral mean dose of between 5.2 and 7.8 Gy for the most proximal paratracheal nodal stations (2R and 4R for right upper lobe lesions, 2L and 4L for left upper lobe lesions). SBRT to lower lobe tumors resulted in an average total ipsilateral mean dose of between 15.6 and 21.5 Gy for the most proximal hilar nodal stations (10R for right lower lobe lesions, 10 l for left lower lobe lesions). Doses to more distal nodes were substantially lower than 5 Gy. The often substantial incidental irradiation, delivered during SBRT for peripheral NSCLC of the lower lobes to the most proximal hilar lymph nodes may be therapeutic for low-volume, subclinical nodal disease. Treatment of peripheral upper lobe lung tumors delivers less incidental irradiation to the paratracheal lymph nodes with lower likelihood of therapeutic benefit.

  15. Dosimetric evaluation of the impacts of different heterogeneity correction algorithms on target doses in stereotactic body radiation therapy for lung tumors

    International Nuclear Information System (INIS)

    Narabayashi, Masaru; Mizowaki, Takashi; Matsuo, Yukinori; Nakamura, Mitsuhiro; Takayama, Kenji; Norihisa, Yoshiki; Sakanaka, Katsuyuki; Hiraoka, Masahiro

    2012-01-01

    Heterogeneity correction algorithms can have a large impact on the dose distributions of stereotactic body radiation therapy (SBRT) for lung tumors. Treatment plans of 20 patients who underwent SBRT for lung tumors with the prescribed dose of 48 Gy in four fractions at the isocenter were reviewed retrospectively and recalculated with different heterogeneity correction algorithms: the pencil beam convolution algorithm with a Batho power-law correction (BPL) in Eclipse, the radiological path length algorithm (RPL), and the X-ray Voxel Monte Carlo algorithm (XVMC) in iPlan. The doses at the periphery (minimum dose and D95) of the planning target volume (PTV) were compared using the same monitor units among the three heterogeneity correction algorithms, and the monitor units were compared between two methods of dose prescription, that is, an isocenter dose prescription (IC prescription) and dose-volume based prescription (D95 prescription). Mean values of the dose at the periphery of the PTV were significantly lower with XVMC than with BPL using the same monitor units (P<0.001). In addition, under IC prescription using BPL, RPL and XVMC, the ratios of mean values of monitor units were 1, 0.959 and 0.986, respectively. Under D95 prescription, they were 1, 0.937 and 1.088, respectively. These observations indicated that the application of XVMC under D95 prescription results in an increase in the actually delivered dose by 8.8% on average compared with the application of BPL. The appropriateness of switching heterogeneity correction algorithms and dose prescription methods should be carefully validated from a clinical viewpoint. (author)

  16. The evaluation of a deformable image registration segmentation technique for semi-automating internal target volume (ITV) production from 4DCT images of lung stereotactic body radiotherapy (SBRT) patients

    International Nuclear Information System (INIS)

    Speight, Richard; Sykes, Jonathan; Lindsay, Rebecca; Franks, Kevin; Thwaites, David

    2011-01-01

    Purpose: To evaluate a deformable image registration (DIR) segmentation technique for semi-automating ITV production from 4DCT for lung patients, in terms of accuracy and efficiency. Methods: Twenty-five stereotactic body radiotherapy lung patients were selected in this retrospective study. ITVs were manually delineated by an oncologist and semi-automatically produced by propagating the GTV manually delineated on the mid-ventilation phase to all other phases using two different DIR algorithms, using commercial software. The two ITVs produced by DIR were compared to the manually delineated ITV using the dice similarity coefficient (DSC), mean distance between agreement and normalised DSC. DIR-produced ITVs were assessed for their clinical suitability and also the time savings were estimated. Results: Eighteen out of 25 ITVs had normalised DSC > 1 indicating an agreement with the manually produced ITV within 1 mm uncertainty. Four of the other seven ITVs were deemed clinically acceptable and three would require a small amount of editing. In general, ITVs produced by DIR were smoother than those produced by manual delineation. It was estimated that using this technique would save clinicians on average 28 min/patient. Conclusions: ABAS was found to be a useful tool in the production of ITVs for lung patients. The ITVs produced are either immediately clinically acceptable or require minimal editing. This approach represents a significant time saving for clinicians.

  17. Linac based radiosurgery and stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2008-01-01

    The following topics were discussed: Definition of stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT); Stereo market; Indications for SRS/SRT; History of linac-based SRS/SRT; Variety of systems; QA for SRS; Localization; and Imaging. (P.A.)

  18. A Multidisciplinary Evaluation of a Web-based eLearning Training Programme for SAFRON II (TROG 13.01): a Multicentre Randomised Study of Stereotactic Radiotherapy for Lung Metastases.

    Science.gov (United States)

    Pham, D; Hardcastle, N; Foroudi, F; Kron, T; Bressel, M; Hilder, B; Chesson, B; Oates, R; Montgomery, R; Ball, D; Siva, S

    2016-09-01

    In technically advanced multicentre clinical trials, participating centres can benefit from a credentialing programme before participating in the trial. Education of staff in participating centres is an important aspect of a successful clinical trial. In the multicentre study of fractionated versus single fraction stereotactic ablative body radiotherapy in lung oligometastases (TROG 13.01), knowledge transfer of stereotactic ablative body radiotherapy techniques to the local multidisciplinary team is intended as part of the credentialing process. In this study, a web-based learning platform was developed to provide education and training for the multidisciplinary trial teams at geographically distinct sites. A web-based platform using eLearning software consisting of seven training modules was developed. These modules were based on extracranial stereotactic theory covering the following discrete modules: Clinical background; Planning technique and evaluation; Planning optimisation; Four-dimensional computed tomography simulation; Patient-specific quality assurance; Cone beam computed tomography and image guidance; Contouring organs at risk. Radiation oncologists, medical physicists and radiation therapists from hospitals in Australia and New Zealand were invited to participate in this study. Each discipline was enrolled into a subset of modules (core modules) and was evaluated before and after completing each module. The effectiveness of the eLearning training will be evaluated based on (i) knowledge retention after participation in the web-based training and (ii) confidence evaluation after participation in the training. Evaluation consisted of a knowledge test and confidence evaluation using a Likert scale. In total, 130 participants were enrolled into the eLearning programme: 81 radiation therapists (62.3%), 27 medical physicists (20.8%) and 22 radiation oncologists (16.9%). There was an average absolute improvement of 14% in test score (P 4 weeks) after

  19. Critical dose and toxicity index of organs at risk in radiotherapy: Analyzing the calculated effects of modified dose fractionation in non–small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pedicini, Piernicola, E-mail: ppiern@libero.it [Service of Medical Physics, I.R.C.C.S. Regional Cancer Hospital C.R.O.B, Rionero in Vulture (Italy); Strigari, Lidia [Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer Institute, Rome (Italy); Benassi, Marcello [Service of Medical Physics, Scientific Institute of Tumours of Romagna I.R.S.T., Meldola (Italy); Caivano, Rocchina [Service of Medical Physics, I.R.C.C.S. Regional Cancer Hospital C.R.O.B, Rionero in Vulture (Italy); Fiorentino, Alba [U.O. of Radiotherapy, I.R.C.C.S. Regional Cancer Hospital C.R.O.B., Rionero in Vulture (Italy); Nappi, Antonio [U.O. of Nuclear Medicine, I.R.C.C.S. Regional Cancer Hospital C.R.O.B., Rionero in Vulture (Italy); Salvatore, Marco [U.O. of Nuclear Medicine, I.R.C.C.S. SDN Foundation, Naples (Italy); Storto, Giovanni [U.O. of Nuclear Medicine, I.R.C.C.S. Regional Cancer Hospital C.R.O.B., Rionero in Vulture (Italy)

    2014-04-01

    To increase the efficacy of radiotherapy for non–small cell lung cancer (NSCLC), many schemes of dose fractionation were assessed by a new “toxicity index” (I), which allows one to choose the fractionation schedules that produce less toxic treatments. Thirty-two patients affected by non resectable NSCLC were treated by standard 3-dimensional conformal radiotherapy (3DCRT) with a strategy of limited treated volume. Computed tomography datasets were employed to re plan by simultaneous integrated boost intensity-modulated radiotherapy (IMRT). The dose distributions from plans were used to test various schemes of dose fractionation, in 3DCRT as well as in IMRT, by transforming the dose-volume histogram (DVH) into a biological equivalent DVH (BDVH) and by varying the overall treatment time. The BDVHs were obtained through the toxicity index, which was defined for each of the organs at risk (OAR) by a linear quadratic model keeping an equivalent radiobiological effect on the target volume. The less toxic fractionation consisted in a severe/moderate hyper fractionation for the volume including the primary tumor and lymph nodes, followed by a hypofractionation for the reduced volume of the primary tumor. The 3DCRT and IMRT resulted, respectively, in 4.7% and 4.3% of dose sparing for the spinal cord, without significant changes for the combined-lungs toxicity (p < 0.001). Schedules with reduced overall treatment time (accelerated fractionations) led to a 12.5% dose sparing for the spinal cord (7.5% in IMRT), 8.3% dose sparing for V{sub 20} in the combined lungs (5.5% in IMRT), and also significant dose sparing for all the other OARs (p < 0.001). The toxicity index allows to choose fractionation schedules with reduced toxicity for all the OARs and equivalent radiobiological effect for the tumor in 3DCRT, as well as in IMRT, treatments of NSCLC.

  20. Head-and-neck IMRT treatments assessed with a Monte Carlo dose calculation engine

    International Nuclear Information System (INIS)

    Seco, J; Adams, E; Bidmead, M; Partridge, M; Verhaegen, F

    2005-01-01

    IMRT is frequently used in the head-and-neck region, which contains materials of widely differing densities (soft tissue, bone, air-cavities). Conventional methods of dose computation for these complex, inhomogeneous IMRT cases involve significant approximations. In the present work, a methodology for the development, commissioning and implementation of a Monte Carlo (MC) dose calculation engine for intensity modulated radiotherapy (MC-IMRT) is proposed which can be used by radiotherapy centres interested in developing MC-IMRT capabilities for research or clinical evaluations. The method proposes three levels for developing, commissioning and maintaining a MC-IMRT dose calculation engine: (a) development of a MC model of the linear accelerator, (b) validation of MC model for IMRT and (c) periodic quality assurance (QA) of the MC-IMRT system. The first step, level (a), in developing an MC-IMRT system is to build a model of the linac that correctly predicts standard open field measurements for percentage depth-dose and off-axis ratios. Validation of MC-IMRT, level (b), can be performed in a rando phantom and in a homogeneous water equivalent phantom. Ultimately, periodic quality assurance of the MC-IMRT system is needed to verify the MC-IMRT dose calculation system, level (c). Once the MC-IMRT dose calculation system is commissioned it can be applied to more complex clinical IMRT treatments. The MC-IMRT system implemented at the Royal Marsden Hospital was used for IMRT calculations for a patient undergoing treatment for primary disease with nodal involvement in the head-and-neck region (primary treated to 65 Gy and nodes to 54 Gy), while sparing the spinal cord, brain stem and parotid glands. Preliminary MC results predict a decrease of approximately 1-2 Gy in the median dose of both the primary tumour and nodal volumes (compared with both pencil beam and collapsed cone). This is possibly due to the large air-cavity (the larynx of the patient) situated in the centre

  1. Survival Outcome After Stereotactic Body Radiation Therapy and Surgery for Stage I Non-Small Cell Lung Cancer: A Meta-Analysis

    International Nuclear Information System (INIS)

    Zheng, Xiangpeng; Schipper, Matthew; Kidwell, Kelley; Lin, Jules; Reddy, Rishindra; Ren, Yanping; Chang, Andrew; Lv, Fanzhen; Orringer, Mark; Spring Kong, Feng-Ming

    2014-01-01

    Purpose: This study compared treatment outcomes of stereotactic body radiation therapy (SBRT) with those of surgery in stage I non-small cell lung cancer (NSCLC). Methods and Materials: Eligible studies of SBRT and surgery were retrieved through extensive searches of the PubMed, Medline, Embase, and Cochrane library databases from 2000 to 2012. Original English publications of stage I NSCLC with adequate sample sizes and adequate SBRT doses were included. A multivariate random effects model was used to perform a meta-analysis to compare survival between treatments while adjusting for differences in patient characteristics. Results: Forty SBRT studies (4850 patients) and 23 surgery studies (7071 patients) published in the same period were eligible. The median age and follow-up duration were 74 years and 28.0 months for SBRT patients and 66 years and 37 months for surgery patients, respectively. The mean unadjusted overall survival rates at 1, 3, and 5 years with SBRT were 83.4%, 56.6%, and 41.2% compared to 92.5%, 77.9%, and 66.1% with lobectomy and 93.2%, 80.7%, and 71.7% with limited lung resections. In SBRT studies, overall survival improved with increasing proportion of operable patients. After we adjusted for proportion of operable patients and age, SBRT and surgery had similar estimated overall and disease-free survival. Conclusions: Patients treated with SBRT differ substantially from patients treated with surgery in age and operability. After adjustment for these differences, OS and DFS do not differ significantly between SBRT and surgery in patients with operable stage I NSCLC. A randomized prospective trial is warranted to compare the efficacy of SBRT and surgery

  2. Survival Outcome After Stereotactic Body Radiation Therapy and Surgery for Stage I Non-Small Cell Lung Cancer: A Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Xiangpeng [Department of Radiation Oncology, Huadong Hospital, Fudan University, Shanghai (China); Schipper, Matthew [Department of Radiation Oncology, the University of Michigan, Ann Arbor, Michigan (United States); Department of Biostatistics, the University of Michigan, Ann Arbor, Michigan (United States); Kidwell, Kelley [Department of Biostatistics, the University of Michigan, Ann Arbor, Michigan (United States); Lin, Jules; Reddy, Rishindra [Department of Surgery, Section of Thoracic Surgery, University of Michigan, Ann Arbor, Michigan (United States); Ren, Yanping [Department of Radiation Oncology, Huadong Hospital, Fudan University, Shanghai (China); Chang, Andrew [Department of Surgery, Section of Thoracic Surgery, University of Michigan, Ann Arbor, Michigan (United States); Lv, Fanzhen [Department of Thoracic Surgery, Huadong Hospital, Fudan University, Shanghai (China); Orringer, Mark [Department of Surgery, Section of Thoracic Surgery, University of Michigan, Ann Arbor, Michigan (United States); Spring Kong, Feng-Ming, E-mail: Fkong@gru.edu [Department of Radiation Oncology, the University of Michigan, Ann Arbor, Michigan (United States)

    2014-11-01

    Purpose: This study compared treatment outcomes of stereotactic body radiation therapy (SBRT) with those of surgery in stage I non-small cell lung cancer (NSCLC). Methods and Materials: Eligible studies of SBRT and surgery were retrieved through extensive searches of the PubMed, Medline, Embase, and Cochrane library databases from 2000 to 2012. Original English publications of stage I NSCLC with adequate sample sizes and adequate SBRT doses were included. A multivariate random effects model was used to perform a meta-analysis to compare survival between treatments while adjusting for differences in patient characteristics. Results: Forty SBRT studies (4850 patients) and 23 surgery studies (7071 patients) published in the same period were eligible. The median age and follow-up duration were 74 years and 28.0 months for SBRT patients and 66 years and 37 months for surgery patients, respectively. The mean unadjusted overall survival rates at 1, 3, and 5 years with SBRT were 83.4%, 56.6%, and 41.2% compared to 92.5%, 77.9%, and 66.1% with lobectomy and 93.2%, 80.7%, and 71.7% with limited lung resections. In SBRT studies, overall survival improved with increasing proportion of operable patients. After we adjusted for proportion of operable patients and age, SBRT and surgery had similar estimated overall and disease-free survival. Conclusions: Patients treated with SBRT differ substantially from patients treated with surgery in age and operability. After adjustment for these differences, OS and DFS do not differ significantly between SBRT and surgery in patients with operable stage I NSCLC. A randomized prospective trial is warranted to compare the efficacy of SBRT and surgery.

  3. Once-Weekly, High-Dose Stereotactic Body Radiotherapy for Lung Cancer: 6-Year Analysis of 60 Early-Stage, 42 Locally Advanced, and 7 Metastatic Lung Cancers

    International Nuclear Information System (INIS)

    Salazar, Omar M.; Sandhu, Taljit S.; Lattin, Paul B.; Chang, Jung H.; Lee, Choon K.; Groshko, Gayle A.; Lattin, Cheryl J.

    2008-01-01

    Purpose: To explore once-weekly stereotactic body radiotherapy (SBRT) in nonoperable patients with localized, locally advanced, or metastatic lung cancer. Methods and Materials: A total of 102 primary (89 untreated plus 13 recurrent) and 7 metastatic tumors were studied. The median follow-up was 38 months, the average patient age was 75 years. Of the 109 tumors studied, 60 were Stage I (45 IA and 15 IB), 9 were Stage II, 30 were Stage III, 3 were Stage IV, and 7 were metastases. SBRT only was given in 73% (40 Gy in four fractions to the planning target volume to a total dose of 53 Gy to the isocenter for a biologically effective dose of 120 Gy 10 ). SBRT was given as a boost in 27% (22.5 Gy in three fractions once weekly for a dose of 32 Gy at the isocenter) after 45 Gy in 25 fractions to the primary plus the mediastinum. The total biologically effective dose was 120 Gy 10 . Respiration gating was used in 46%. Results: The overall response rate was 75%; 33% had a complete response. The overall response rate was 89% for Stage IA patients (40% had a complete response). The local control rate was 82%; it was 100% and 93% for Stage IA and IB patients, respectively. The failure rate was 37%, with 17% within the planning target volume. No Grade 3-4 acute toxicities developed in any patient; 12% and 7% of patients developed Grade 1 and 2 toxicities, respectively. Late toxicity, all Grade 2, developed in 3% of patients. The 5-year cause-specific survival rate for Stage I was 70% and was 74% and 64% for Stage IA and IB patients, respectively. The 3-year Stage III cause-specific survival rate was 30%. The patients with metastatic lung cancer had a 57% response rate, a 27% complete response rate, an 86% local control rate, a median survival time of 19 months, and 23% 3-year survival rate. Conclusions: SBRT is noninvasive, convenient, fast, and economically attractive; it achieves results similar to surgery for early or metastatic lung cancer patients who are older

  4. Stereotactic radiotherapy for vestibular schwannoma

    DEFF Research Database (Denmark)

    Muzevic, Dario; Legcevic, Jelena; Splavski, Bruno

    2014-01-01

    BACKGROUND: Vestibular schwannomas (acoustic neuromas) are common benign tumours that arise from the Schwann cells of the vestibular nerve. Management options include observation with neuroradiological follow-up, microsurgical resection and stereotactic radiotherapy. OBJECTIVES: To assess...... the effect of stereotactic radiotherapy compared to observation, microsurgical resection, any other treatment modality, or a combination of two or more of the above approaches for vestibular schwannoma. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials; PubMed; EMBASE; CINAHL......; Web of Science; CAB Abstracts; ISRCTN and additional sources for published and unpublished trials. The date of the search was 24 July 2014. SELECTION CRITERIA: Randomised controlled trials (RCTs) exploring the efficacy of stereotactic radiotherapy compared with observation alone, microsurgical...

  5. Stereotactic radiotherapy for brain metastasis

    International Nuclear Information System (INIS)

    Noel, G.; Daisne, J.F.; Thillays, F.

    2012-01-01

    Stereotactic radiosurgery is now well implanted in the radiotherapy treatment tools of brain metastasis. The dose can be delivered in one or multiple sessions. Results seem equivalent. CT scan and MRI imaging are required to delineate and calculate dosimetry. Doses are variable according to the size of the metastases, localization, pathology or equipment. Stabilization or reduction of tumour size is the rules after stereotactic treatment. Impact in terms of overall survival is more difficult to apprehend because of the general context of the disease. Many questions remain unresolved, such as the usefulness of whole brain irradiation, adaptation of the treatment schedule to tumour pathophysiology, role of stereotactic treatment after surgery of metastases, etc. (authors)

  6. Patients burden in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Kralik, G.; Fribertova, M.; Trosanova, D.; Kolarcikova, E.

    2009-01-01

    Radiosurgery is one time application of High radiation to a stereotactically defined volume. Treatment delivery involves multiple stereotactically targeted, arced fields. The goal of Radiosurgery is to deliver a high dose to target, while only a minimum dose is delivered to adjacent normal tissue that are just a few millimeters away . Stereotactic Radiosurgery on linac has been employed at St. Elisabeth Cancer Institute in Bratislava since 1993. Until July 31,2008, 1 030 subjects have been treated including patients with brain tumors, metastases, recurrent tumours, and A V malformations, using Leibinger stereotaxy collimators or Mimic MLC system on a Linac accelerator. The presentation shows dose delivery to risk organs in different indications. (authors)

  7. Intensity modulated radiotherapy (IMRT) in bilateral retinoblastoma

    International Nuclear Information System (INIS)

    Atalar, Banu; Ozyar, Enis; Gunduz, Kaan; Gungor, Gorkem

    2010-01-01

    External beam radiotherapy (EBRT) for retinoblastoma has traditionally been done with conventional radiotherapy techniques which resulted high doses to the surrounding normal tissues. A 20 month-old girl with group D bilateral retinoblastoma underwent intensity modulated radiotherapy (IMRT) to both eyes after failing chemoreduction and focal therapies including cryotherapy and transpupillary thermotherapy. In this report, we discuss the use of IMRT as a method for reducing doses to adjacent normal tissues while delivering therapeutic doses to the tumour tissues compared with 3-dimensional conformal radiotherapy (3DCRT). At one year follow-up, the patient remained free of any obvious radiation complications. Image guided IMRT provides better dose distribution than 3DCRT in retinoblastoma eyes, delivering the therapeutic dose to the tumours and minimizing adjacent tissue damage

  8. Tomotherapy: IMRT and tomographic verification

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2000-01-01

    Full text: External beam radiation therapy delivery began around the turn of the century with the use of one or a few kilovoltage beams directed to the presumed site of the tumor. Often the treatment lasted until erythema dose was reached. Delivering the beams rotationally allowed the dose to be focused on the tumor and the skin to be spared. With the advent of megavoltage radiation therapy in the 1950's, using Co-60 teletherapy and betatrons, the treatment could once again be delivered from only a few beam directions and the dose to the skin would be kept below tolerance. Fields were shaped by lead blocks and later by custom-made blocks fabricated from low-melting temperature heavy metal. Linear accelerators did not fundamentally change the way in which radiation was delivered. It is likely that this delivery paradigm would not have changed had it not been for the advent of computers. Brahme and Cormack showed in the late 1980's that highly conformal treatments could be delivered with non-uniform intensity beams. At that time the only way in which the intensity modulated beams could be delivered was using custom-milled compensators. Fabricating and using compensators for multiple fields is time-consuming and labor-intensive. Serial tomotherapy was the first successful delivery method for IMRT and went back to the earlier practice of rotation therapy. The NOMOS Peacock system uses a binary (on-off) multileaf collimator (MLC) system to modulate a fan beam of radiation. It uses an optimization system to determine when leaves should be opened and closed. The system delivers two beam slices at once and the couch is indexed to the next slices by precisely translating the couch. This approach was first used in 1994 and to-date has treated several thousand patients. Prior to the advent of IMRT, accelerator vendors introduced the multileaf collimator (MLC) to provide field shaping without the need to fabricate custom blocking. Most new linear accelerator purchases today

  9. Propensity Score Matched Comparison of Intensity Modulated Radiation Therapy vs Stereotactic Body Radiation Therapy for Localized Prostate Cancer: A Survival Analysis from the National Cancer Database

    Directory of Open Access Journals (Sweden)

    Anthony Ricco

    2017-08-01

    Full Text Available PurposeNo direct comparisons between extreme hypofractionation and conventional fractionation have been reported in randomized trials for the treatment of localized prostate cancer. The goal of this study is to use a propensity score matched (PSM analysis with the National Cancer Database (NCDB for the comparison of stereotactic body radiation therapy (SBRT and intensity modulated radiation therapy (IMRT for organ confined prostate cancer.MethodsMen with localized prostate cancer treated with radiation dose ≥72 Gy for IMRT and ≥35 Gy for SBRT to the prostate only were abstracted from the NCDB. Men treated with previous surgery, brachytherapy, or proton therapy were excluded. Matching was performed to eliminate confounding variables via PSM. Simple 1–1 nearest neighbor matching resulted in a matched sample of 5,430 (2,715 in each group. Subset analyses of men with prostate-specific antigen (PSA > 10, GS = 7, and GS > 7 yielded matched samples of 1,020, 2,194, and 247, respectively.ResultsNo difference in survival was noted between IMRT and SBRT at 8 years (p = 0.65. Subset analyses of higher risk men with PSA > 10 or GS = 7 histology or GS > 7 histology revealed no difference in survival between IMRT and SBRT (p = 0.58, p = 0.68, and p = 0.62, respectively. Variables significant for survival for the matched group included: age (p < 0.0001, primary payor (p = 0.0001, Charlson/Deyo Score (p = 0.0002, PSA (p = 0.0013, Gleason score (p < 0.0001, and use of hormone therapy (p = 0.02.ConclusionUtilizing the NCDB, there is no difference in survival at 8 years comparing IMRT to SBRT in the treatment of localized prostate cancer. Subset analysis confirmed no difference in survival even for intermediate- and high-risk patients based on Gleason Score and PSA.

  10. Planning benchmark study for SBRT of early stage NSCLC. Results of the DEGRO Working Group Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Moustakis, Christos [University Muenster, Department of Radiation Oncology, Muenster (Germany); German CyberKnife Center, Soest (Germany); Blanck, Oliver [UKSH Universitaetsklinikum Schleswig Holstein, Department of Radiation Oncology, Kiel (Germany); Saphir Radiosurgery Center, Guestrow and Frankfurt, Frankfurt (Germany); Ebrahimi Tazehmahalleh, Fatemeh [University Muenster, Department of Radiation Oncology, Muenster (Germany); City Hospital Dessau, Dessau (Germany); Chan, Mark ka heng [UKSH Universitaetsklinikum Schleswig Holstein, Department of Radiation Oncology, Kiel (Germany); Ernst, Iris; Haverkamp, Uwe; Eich, Hans Theodor [University Muenster, Department of Radiation Oncology, Muenster (Germany); German CyberKnife Center, Soest (Germany); Krieger, Thomas [University of Wuerzburg, Department of Radiation Oncology, Wuerzburg (Germany); Duma, Marciana-Nona; Oechsner, Markus [Technical University of Munich, Department of Radiation Oncology, Klinikum rechts der Isar, Munich (Germany); Ganswindt, Ute; Heinz, Christian [Ludwig-Maximilians-University, Department of Radiation Oncology, Munich (Germany); Alheit, Horst; Blank, Hilbert [Radiationtherapy Distler, Bautzen (Germany); Nestle, Ursula; Wiehle, Rolf [University Medical Center Freiburg, Department of Radiation Oncology, Freiburg (Germany); Kornhuber, Christine; Ostheimer, Christian [University Halle, Department of Radiation Oncology, Halle (Germany); Petersen, Cordula [University Hospital Hamburg-Eppendorf, Hamburg (Germany); Pollul, Gerhard [University Mainz, Department of Radiation Oncology, Mainz (Germany); Baus, Wolfgang; Altenstein, Georg [University Hospital of Cologne, Cologne (Germany); Beckers, Eric; Jurianz, Katrin [Gamma Knife Center Krefeld, Krefeld (Germany); Sterzing, Florian [University Hospital Heidelberg, Heidelberg (Germany); Kretschmer, Matthias [Radiologische Allianz Hamburg, Hamburg (Germany); Seegenschmiedt, Heinrich; Maass, Torsten [Radiationtherapy and Cyberknife Center Hamburg, Hamburg (Germany); Droege, Stefan [Lung Clinic Hemer, Hemer (Germany); Wolf, Ulrich [University Leipzig, Department of Radiation Oncology, Leipzig (Germany); Schoeffler, Juergen [Radiationtherapy Department Boeblingen, Boeblingen (Germany); Guckenberger, Matthias [University Zurich, Department of Radiation Oncology, Zurich (Switzerland)

    2017-10-15

    The aim was to evaluate stereotactic body radiation therapy (SBRT) treatment planning variability for early stage nonsmall cell lung cancer (NSCLC) with respect to the published guidelines of the Stereotactic Radiotherapy Working Group of the German Society for Radiation Oncology (DEGRO). Planning computed tomography (CT) scan and the structure sets (planning target volume, PTV; organs at risk, OARs) of 3 patients with early stage NSCLC were sent to 22 radiotherapy departments with SBRT experience: each department was asked to prepare a treatment plan according to the DEGRO guidelines. The prescription dose was 3 fractions of 15 Gy to the 65% isodose. In all, 87 plans were generated: 36 used intensity-modulated arc therapy (IMAT), 21 used three-dimensional conformal radiation therapy (3DCRT), 6 used static field intensity-modulated radiation therapy (SF-IMRT), 9 used helical radiotherapy and 15 used robotic radiosurgery. PTV dose coverage and simultaneously kept OARs doses were within the clinical limits published in the DEGRO guidelines. However, mean PTV dose (mean 58.0 Gy, range 52.8-66.4 Gy) and dose conformity indices (mean 0.75, range 0.60-1.00) varied between institutions and techniques (p ≤ 0.02). OARs doses varied substantially between institutions, but appeared to be technique independent (p = 0.21). All studied treatment techniques are well suited for SBRT of early stage NSCLC according to the DEGRO guidelines. Homogenization of SBRT practice in Germany is possible through the guidelines; however, detailed treatment plan characteristics varied between techniques and institutions and further homogenization is warranted in future studies and recommendations. Optimized treatment planning should always follow the ALARA (as low as reasonably achievable) principle. (orig.) [German] Ziel war die Untersuchung der Variabilitaet der Bestrahlungsplanung der stereotaktischen Strahlentherapie (SBRT) fuer das nicht-kleinzellige Bronchialkarzinom (NSCLC) im

  11. Radiological differential diagnosis between fibrosis and recurrence after stereotactic body radiation therapy (SBRT) in early stage non-small cell lung cancer (NSCLC).

    Science.gov (United States)

    Frakulli, Rezarta; Salvi, Fabrizio; Balestrini, Damiano; Palombarini, Marcella; Akshija, Ilir; Cammelli, Silvia; Morganti, Alessio Giuseppe; Zompatori, Maurizio; Frezza, Giovanni

    2017-12-01

    Parenchymal changes after stereotactic body radiation therapy (SBRT) make differential diagnosis between treatment outcomes and disease recurrence often difficult. The purpose of our study was to identify the radiographic features detectable at computed tomography (CT) scan [high-risk features (HRFs)] that allow enough specificity and sensitivity for early detection of recurrence. We retrospectively evaluated patients who underwent SBRT for inoperable early stage non-small cell lung cancer (NSCLC). The median delivered dose performed was 50 Gy in 5 fractions prescribed to 80% isodose. All patients underwent chest CT scan before SBRT and at 3, 6, 12, 18, 24 months after, and then annually. Each CT scan was evaluated and benign and HRFs were recorded. 18 F-fluorodeoxyglucose-CT was not used routinely. Forty-five patients were included (34 males, 11 females; median age: 77 years; stage IA: 77.8%, stage IB: 22.2%; median follow-up: 21.7 months). Two year and actuarial local control was 77%. HRFs were identified in 20 patients. The most significant predictor of relapse was an enlarging opacity at 12 months (P2 HRFs.

  12. A study to 3D dose measurement and evaluation for respiratory motion in lung cancer stereotactic body radiotherapy treatment

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Byeong Geol; Choi, Chang Heon; Yun, Il Gyu; Yang, Jin Seong; Lee, Dong Myeong; Park, Ju Mi [Dept. of Radiation Oncology, VHS Medical Center, Seoul (Korea, Republic of)

    2014-06-15

    This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four dimensional computed tomography (4DCT) study was performed . We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03∼0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with V{sub 20}, V{sub 10}, V{sub 5} of Lung was -0.04%∼2.32%. The average Homogeneity Index difference between MIP and each phase 3D data of all patient was -0.03∼0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of V{sub 20}, V{sub 10}, V{sub 5} of Lung show bo certain trend. There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

  13. IMRT for adjuvant radiation in gastric cancer: A preferred plan?

    International Nuclear Information System (INIS)

    Ringash, Jolie; Perkins, Greg; Brierley, James; Lockwood, Gina; Islam, Mohammad; Catton, Pamela; Cummings, Bernard; Kim, John; Wong, Rebecca; Dawson, Laura

    2005-01-01

    Purpose: To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over conformal planning for postoperative adjuvant radiotherapy in patients with gastric carcinoma. Methods and Materials: Twenty patients who had undergone treatment planning with conformal beam arrangements for 4500 cGy adjuvant radiotherapy between 2000 and 2001 underwent repeat planning using IMRT techniques. Conformal five-field plans were compared with seven- to nine-field coplanar sliding-window IMRT plans. For each patient, the cumulative dose-volume histograms and organ-dose summaries (without distributions or digitally reconstructed radiographs) were provided to two independent, 'blinded' GI radiation oncologists. The oncologists indicated which plan provided better planning target volume coverage and critical organ sparing, any safety concerns with either plan, and which plan they would choose to treat the patient. Results: In 18 (90%) of 20 cases, both oncologists chose the same plan. Cases with disagreement were given to a third 'blinded' reviewer. A 'preferred plan' could be determined in 19 (95%) of 20 cases. IMRT was preferred in 17 (89%) of 19 cases. In 4 (20%) of 20 IMRT plans at least one radiation oncologist had safety concerns because of the spinal cord dose (3 cases) or small bowel dose (2 cases). Of 42 ratings, IMRT was thought to provide better planning target volume coverage in 36 (86%) and better sparing of the spinal cord in 31 (74%) of 42, kidneys in 29 (69%), liver in 30 (71%), and heart in 29 (69%) of 42 ratings. The median underdose volume (1.7 vs. 4.1 cm 3 ), maximal dose to the spinal cord (36.85 vs. 45.65 Gy), and dose to 50% of the liver (17.29 vs. 27.97), heart (12.89 vs. 15.50 Gy), and left kidney (15.50 vs. 16.06 Gy) were lower with IMRT than with the conformal plans. Conclusion: Compared with the conformal plans, oncologists frequently preferred IMRT plans when using dose-volume histogram data. The advantages of IMRT plans include both

  14. Emphasizing Conformal Avoidance Versus Target Definition for IMRT Planning in Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Harari, Paul M.; Song Shiyu; Tome, Wolfgang A.

    2010-01-01

    Purpose: To describe a method for streamlining the process of elective nodal volume definition for head-and-neck (H and N) intensity-modulated radiotherapy (IMRT) planning. Methods and Materials: A total of 20 patients who had undergone curative-intent RT for H and N cancer underwent comprehensive treatment planning using three distinct, plan design techniques: conventional three-field design, target-defined IMRT (TD-IMRT), and conformal avoidance IMRT (CA-IMRT). For each patient, the conventional three-field design was created first, thereby providing the 'outermost boundaries' for subsequent IMRT design. In brief, TD-IMRT involved physician contouring of the gross tumor volume, high- and low-risk clinical target volume, and normal tissue avoidance structures on consecutive 1.25-mm computed tomography images. CA-IMRT involved physician contouring of the gross tumor volume and normal tissue avoidance structures only. The overall physician time for each approach was monitored, and the resultant plans were rigorously compared. Results: The average physician working time for the design of the respective H and N treatment contours was 0.3 hour for the conventional three-field design plan, 2.7 hours for TD-IMRT, and 0.9 hour for CA-IMRT. Dosimetric analysis confirmed that the largest volume of tissue treated to an intermediate (50 Gy) and high (70 Gy) dose occurred with the conventional three-field design followed by CA-IMRT and then TD-IMRT. However, for the two IMRT approaches, comparable results were found in terms of salivary gland and spinal cord protection. Conclusion: CA-IMRT for H and N treatment offers an alternative to TD-IMRT. The overall time for physician contouring was substantially reduced (approximately threefold), yielding a more standardized elective nodal volume. Because of the complexity of H and N IMRT target design, CA-IMRT might ultimately prove a safer and more reliable method to export to general radiation oncology practitioners, particularly

  15. Inverse IMRT workflow process at Austin health

    International Nuclear Information System (INIS)

    Rykers, K.; Fernando, W.; Grace, M.; Liu, G.; Rolfo, A.; Viotto, A.; Mantle, C.; Lawlor, M.; Au-Yeung, D.; Quong, G.; Feigen, M.; Lim-Joon, D.; Wada, M.

    2004-01-01

    Full text: The work presented here will review the strategies adopted at Austin Health to bring IMRT into clinical use. IMRT is delivered using step and shoot mode on an Elekta Precise machine with 40 pairs of 1cm wide MLC leaves. Planning is done using CMS Focus/XiO. A collaborative approach for RO's, Physicists and RTs from concept to implementation was adopted. An overview will be given of the workflow for the clinic, the equipment used, tolerance levels and the lessons learned. 1. Strategic Planning for IMRT 2. Training a. MSKCC (New York) b.ESTRO (Amsterdam) c.Elekta (US and UK) 3. Linac testing and data acquisition a. Equipment and software review and selection b. Linac reliability/geometric and mechanical checks c. Draft Patient QA procedure d. EPI Image matching checks and procedures 4. Planning system checks a. export of dose matrix (options) b. dose calculation choices 5. IMRT Research Initiatives a. IMRT Planning Studies, Stabilisation, On-line Imaging 6. Equipment Procurement and testing a. Physics and Linac Equipment, Hardware, Software/Licences, Stabilisation 7. Establishing a DICOM Environment a. Prescription sending, Image transfer for EPI checks b. QA Files 8. Physics QA (Pre-Treatment) a.Clinical plan review; DVH checks b. geometry; dosimetry checks; DICOM checks c. 2D Distance to agreement; mm difference reports; Gamma function index 9. Documentation a.Protocol Development i. ICRU 50/62 reporting and prescribing b. QA for Physics c. QA for RT's d. Generation of a report for RO/patient history. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  16. Intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy for high-grade gliomas: Does IMRT increase the integral dose to normal brain?

    International Nuclear Information System (INIS)

    Hermanto, Ulrich; Frija, Erik K.; Lii, MingFwu J.; Chang, Eric L.; Mahajan, Anita; Woo, Shiao Y.

    2007-01-01

    Purpose: To determine whether intensity-modulated radiotherapy (IMRT) treatment increases the total integral dose of nontarget tissue relative to the conventional three-dimensional conformal radiotherapy (3D-CRT) technique for high-grade gliomas. Methods and Materials: Twenty patients treated with 3D-CRT for glioblastoma multiforme were selected for a comparative dosimetric evaluation with IMRT. Original target volumes, organs at risk (OAR), and dose-volume constraints were used for replanning with IMRT. Predicted isodose distributions, cumulative dose-volume histograms of target volumes and OAR, normal tissue integral dose, target coverage, dose conformity, and normal tissue sparing with 3D-CRT and IMRT planning were compared. Statistical analyses were performed to determine differences. Results: In all 20 patients, IMRT maintained equivalent target coverage, improved target conformity (conformity index [CI] 95% 1.52 vs. 1.38, p mean by 19.8% and D max by 10.7%), optic chiasm (D mean by 25.3% and D max by 22.6%), right optic nerve (D mean by 37.3% and D max by 28.5%), and left optic nerve (D mean by 40.6% and D max by 36.7%), p ≤ 0.01. This was achieved without increasing the total nontarget integral dose by greater than 0.5%. Overall, total integral dose was reduced by 7-10% with IMRT, p < 0.001, without significantly increasing the 0.5-5 Gy low-dose volume. Conclusions: These results indicate that IMRT treatment for high-grade gliomas allows for improved target conformity, better critical tissue sparing, and importantly does so without increasing integral dose and the volume of normal tissue exposed to low doses of radiation

  17. IMRT in hypopharyngeal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Studer, G.; Luetolf, U.M.; Davis, J.B.; Glanzmann, C. [Dept. of Radiation Oncology, Univ. Hospital, Zurich (Switzerland)

    2006-06-15

    Background and purpose: intensity-modulated radiation therapy (IMRT) data on hypopharyngeal cancer (HC) are scant. In this study, the authors report on early results in an own HC patient cohort treated with IMRT. A more favorable outcome as compared to historical data on conventional radiation techniques was expected. Patients and methods: 29 consecutive HC patients were treated with simultaneous integrated boost (SIB) IMRT between 01/2002 and 07/2005 (mean follow-up 16 months, range 4-44 months). Doses of 60-71 Gy with 2.0-2.2 Gy/fraction were applied. 26/29 patients were definitively irradiated, 86% received simultaneous cisplatin-based chemotherapy. 60% presented with locally advanced disease (T3/4 Nx, Tx N2c/3). Mean primary tumor volume measured 36.2 cm{sup 3} (4-170 cm{sup 3}), mean nodal volume 16.6 cm{sup 3} (0-97 cm{sup 3}). Results: 2-year actuarial local, nodal, distant control, and overall disease-free survival were 90%, 93%, 93%, and 90%, respectively. In 2/4 patients with persistent disease (nodal in one, primary in three), salvage surgery was performed. The mean dose to the spinal cord (extension of > 5-15 mm) was 26 Gy (12-38 Gy); the mean maximum (point) dose was 44.4 Gy (26-58.9 Gy). One grade (G) 3 dysphagia and two G4 reactions (laryngeal fibrosis, dysphagia), both following the schedule with 2.2 Gy per fraction, have been observed so far. Larynx preservation was achieved in 25/26 of the definitively irradiated patients (one underwent a salvage laryngectomy); 23 had no or minimal dysphagia (G0-1). Conclusion: excellent early disease control and high patient satisfaction with swallowing function in HC following SIB IMRT were observed; these results need to be confirmed based on a longer follow-up period. In order to avoid G4 reactions, SIB doses of < 2.2 Gy/fraction are recommended for large tumors involving laryngeal structures. (orig.)

  18. Parotid-sparing intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma: Preserved parotid function after IMRT on quantitative salivary scintigraphy, and comparison with historical data after conventional radiotherapy

    International Nuclear Information System (INIS)

    Hsiung, C.-Y.; Ting, H.-M.; Huang, H.-Y.; Lee, C.-H.; Huang, E.-Y.; Hsu, H.-C.

    2006-01-01

    Purpose: To evaluate the parotid function after parotid-sparing intensity-modulated radiotherapy (IMRT) in patients with nasopharyngeal carcinoma (NPC). Methods and Materials: From March 2003 to May 2004, 16 patients with nonmetastatic NPC underwent parotid-sparing IMRT. Eight of these patients had Stage III or IV NPC based on the 1997 American Joint Committee on Cancer staging system. The post-IMRT parotid function was evaluated by quantitative salivary scintigraphy and represented by the maximal excretion ratio (MER) of the parotid gland after sialogogue stimulation. The parotid function of 16 NPC patients who were previously treated with conventional radiotherapy was reviewed as the historical control. Results: In the parotid-sparing IMRT group, all 16 patients were alive and without cancer at the end of follow-up period (median, 24.2 months). The mean parotid MER was 53.5% before radiotherapy, 10.7% at 1 month post-IMRT, and 23.3% at 9 months post-IMRT. In the conventional radiotherapy group, the mean parotid MER was 0.6% at 6 to 12 months postradiotherapy. The difference was statistically significant (23.3% vs. 0.6%, p < 0.001, Mann-Whitney test). In the IMRT group, the mean parotid doses ranged from 33.2 Gy to 58.8 Gy (average, 43.9 Gy). The correlation between the mean parotid dose and the percentage decrease of parotid MER at 9 months post-IMRT (dMER) was statically significant (p = 0.008, Pearson correlation). Conclusions: Although the mean parotid doses are relatively high, the significant preservation of parotid function is achieved with IMRT for NPC patients. The significant correlation between mean parotid dose and parotid dMER demonstrates the dose-function relationship of the parotid gland

  19. Step and shoot IMRT to mobile targets and techniques to mitigate the interplay effect

    International Nuclear Information System (INIS)

    Ehler, Eric D; Tome, Wolfgang A

    2009-01-01

    The purpose of this work is to evaluate a method to mitigate temporal dose variation due to the interplay effect as well as investigate the effect of randomly varying motion patterns. The multi-leaf collimator (MLC) settings from 5, 9 and 11 field step and shoot intensity modulated radiation therapy (IMRT) of non-small cell lung cancer (NSCLC) treatment plans with tumor motion of 1.53, 1.03 and 1.95 cm, respectively, were used. Static planar dose distributions were determined for each treatment field using the Planar Dose Module in the Pinnacle 3 treatment planning system. The MotionSIM XY/4D robotic diode array was used to recreate the tumor motion orthogonal to each treatment beam. Dose rate modulation was investigated as a method to mitigate temporal dose variation due to the interplay effect. Computer simulation was able to identify individual fields where interplay effects are greatest. Computer simulation and physical measurement have shown that temporal dose variation can be mitigated by the selection of the dose rate or by selective dose rate modulation within a given IMRT treatment field. Selective dose rate modulation within a given IMRT treatment field reduced temporal dose variation to levels comparable to whole field dose rate reduction, while also producing shorter radiation delivery times in six of the seven cases investigated. For the cases considered, the interplay effect did not appear to have a greater effect on hypofractionation compared to traditional fractionation even though fewer fractions were delivered. Randomized motion kernel variation was also considered. For this portion of the study, a nine field step and shoot IMRT configuration was considered with a 1.03 cm tumor motion rather than the five field case. In general, if the extent of the variant motion pattern was mostly contained within the target volume, limited impact on the temporal dose variation was observed. In cases where the variant motion kernels increasingly exceeded the

  20. Surgery or stereotactic body radiotherapy for elderly stage I lung cancer? A propensity score matching analysis.

    Science.gov (United States)

    Miyazaki, Takuro; Yamazaki, Takuya; Nakamura, Daisuke; Sato, Shuntaro; Yamasaki, Naoya; Tsuchiya, Tomoshi; Matsumoto, Keitaro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi

    2017-12-01

    The aim of this study was to compare the outcomes of surgery and stereotactic body radiotherapy (SBRT) for elderly clinical stage I non-small cell lung cancer (NSCLC) patients. Patients ≥80 years of age with clinical stage I NSCLC between August 2008 and December 2014 were treated either surgery or SBRT. Propensity score matching was performed to reduce bias in various clinicopathological factors. Surgery was performed in 57 cases and SBRT in 41 cases. In the surgery group, the operations included 34 lobectomies and 23 sublobar resections. In the SBRT group, 27 cases were given 48 Gy in 4 fractions, and 14 were given 60 Gy in 10 fractions. Similar characteristics were identified in age (82 years), gender (male:female ratio 2:1), tumor size (2.2 cm), carcinoembryonic antigen (3.6 ng/ml), Charlson comorbidity index (1), Glasgow prognostic scale (0), and forced expiratory volume in 1 s (1.7 L) after matching. Before matching, the 5-year overall survival (OS) in surgery (68.3%) was significantly better than that in SBRT (47.4%, p = 0.02), and the 5-year disease-specific survival (DSS) (94.1%, 78.2%, p = 0.17) was not significantly different between the groups. The difference in the 5-year OS became non-significant between the matched pairs (57.0%, 49.1%, p = 0.56). The outcomes of surgery and SBRT for elderly patients with the early stage NSCLC were roughly the same.