WorldWideScience

Sample records for stationary neutron radiography

  1. The stationary neutron radiography system

    International Nuclear Information System (INIS)

    Weeks, A.A.; Newell, D.L.; Heidel, C.C.

    1990-01-01

    To provide the high intensity neutron beam and support systems necessary for radiography, the Stationary Neutron Radiography System was constructed at McClellan Air Force Base. The Stationary Neutron Radiography System utilizes a one megawatt TRIGA reactor contained in an Aluminium tank surrounded by eight foot thick concrete walls. There are four neutron beam tubes at inclined angles from the reactor core to separate radiography bays. In three of the bays, robotic systems manipulate aircraft components in the neutron beam, while real-time imaging systems provide images concurrent with the irradiation. Film radiography of smaller components is performed in the remaining bay

  2. The stationary neutron radiography system: a TRIGA-based production neutron radiography facility

    International Nuclear Information System (INIS)

    Chesworth, Robert H.; Hagmann, Dean B.

    1988-01-01

    General Atomics (GA) is under contract to construct a Stationary Neutron Radiography System (SNRS) - on a turnkey basis - at McClellan Air Force Base in Sacramento, California. The SNRS is a custom designed neutron radiography system which will utilize a 1000 KW TRIGA reactor as the neutron source. The partially below-ground reactor will be equipped with four inclined beam tubes originating near the top of the reactor graphite reflector and installed tangential to the reactor core to provide a strong current of thermal neutrons with minimum gamma ray contamination. The inclined beam tubes will terminate in four large bays and will interface with rugged component positioning systems designed to handle intact aircraft wings, other honeycomb aircraft structures, and pyrotechnics. The SNRS will be equipped with real-time, near real-time, and film radiographic imaging systems to provide a broad spectrum of capability for detection of entrained moisture or corrosion in large aircraft panels. GA is prime contractor to the Air Force for the SNRS and is specifically responsible for the TRIGA reactor system and a portion of the neutron beam system design. Science Applications International Corporation and the Lionakis-Beaumont Design Group are principal subcontractors to GA on the project. (author)

  3. Startup data for the Stationary Neutron Radiography Reactor (SNRS)

    International Nuclear Information System (INIS)

    Heidel, C.C.; Richards, W.J.

    1990-01-01

    Moisture and corrosion in the F-lll aluminum honeycomb structure is a significant maintenance problem for these 1960 vintage aircraft. Corrosion and moisture are not readily detectable with conventional nondestructive testing techniques such as X-ray. However, by using neutron radiography, high quality images of the corrosion and moisture within the panels can be obtained. The SNRS-1 TRIGA was developed to provide the high intensity neutron source needed to support systems that enable neutron radiography to be performed on these aircraft parts

  4. DIANE stationary neutron radiography system image quality and industrial applications

    International Nuclear Information System (INIS)

    Cluzeau, S.; Huet, J.; Tourneur, P. le

    1994-01-01

    The SODERN neutron radiography laboratory has operated since February 1993 using a sealed tube generator (GENIE 46). An experimental programme of characterization (dosimetry, spectroscopy) has confirmed the expected performances concerning: neutron flux intensity, neutron energy range, residual gamma flux. Results are given in a specific report [2]. This paper is devoted to the image performance reporting. ASTM and specific indicators have been used to test the image quality with various converters and films. The corresponding modulation transfer functions are to be determined from image processing. Some industrial applications have demonstrated the capabilities of the system: corrosion detection in aircraft parts, ammunitions filling testing, detection of polymer lacks in sandwich steel sheets, detection of moisture in a probe for geophysics, residual ceramic cores imaging in turbine blades. Various computerized electronic imaging systems will be tested to improve the industrial capabilities. (orig.)

  5. Neutron radiography

    International Nuclear Information System (INIS)

    Hrdlicka, Z.

    1977-01-01

    Neutron radiography is a radiographic method using a neutron beam of a defined geometry. The neutron source usually consists of a research reactor, a specialized neutron radiography reactor or the 252 Cf radioisotope source. There are two types of the neutron radiography display system, viz., a system producing neutron radiography images by a photographic process or a system allowing a visual display, eg., using a television monitor. The method can be used wherever X-ray radiography is used except applications in the radiography of humans. The neutron radiography unit at UJV uses the WWR-S reactor as the neutron source and both types of the above mentioned display system. (J.P.)

  6. Neutron radiography

    International Nuclear Information System (INIS)

    Bayon, G.

    1989-01-01

    Neutronography or neutron radiography, a non-destructive test method which is similar in its principle to conventional X-ray photography, presently occupies a marginal position among non-destructive test methods (NDT) (no source of suitable performance or cost). Neutron radiography associated with the ORPHEE reactor permits industrial testing; it can very quickly meet a cost requirement comparable to that of conventional test methods. In 1988, 2500 parts were tested on this unit [fr

  7. Neutron radiography

    International Nuclear Information System (INIS)

    Alaa eldin, M.T.

    2011-01-01

    The digital processing of the neutron radiography images gives the possibility for data quantification. In this case an exact relation between the measured neutron attenuation and the real macroscopic attenuation coefficient for every point of the sample is required. The assumption that the attenuation of the neutron beam through the sample is exponential is valid only in an ideal case where a monochromatic beam, non scattering sample and non background contribution are assumed. In the real case these conditions are not fulfilled and in dependence on the sample material we have more or less deviation from the exponential attenuation law. Because of the high scattering cross-sections of hydrogen (σs=80.26 barn) for thermal neutrons, the problem with the scattered neutrons at quantitative radiography investigations of hydrogenous materials (as PE, Oil, H 2 O, etc) is not trivial. For these strong scattering materials the neutron beam attenuation is no longer exponential and a dependence of the macroscopic attenuation coefficient on the material thickness and on the distance between the sample and the detector appears. When quantitative radiography (2 D) or tomography investigations (3 D) are performed, some image correction procedures for a description of the scattering effect are required. This thesis presents a method that can be used to enhance the neutron radiography image for objects with high scattering materials like hydrogen, carbon and other light materials. This method uses the Monte Carlo code, MCNP5, to simulate the neutron radiography process and get the flux distribution for each pixel of the image and determine the scattered neutrons distribution that causes the image blur and then subtract it from the initial image to improve its quality.

  8. Neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi

    1988-01-01

    The thermal neutron absorption coefficient is essentially different from the X-ray absorption coefficient. Each substance has a characteristic absorption coefficient regardless of its density. Neutron deams have the following features: (1) neutrons are not transmitted efficiently by low molecular weight substances, (2) they are transmitted efficiently by heavy metals, and (3) the transmittance differs among isotopes. Thus, neutron beams are suitable for cheking for foreign matters in heavy metals and testing of composites consisting of both heavy and light materials. A neutron source generates fast neutrons, which should be converted into thermal neutrons by reducing their energy. Major neutron souces include nuclear reactors, radioisotopes and particle accelerators. Photographic films and television systems are mainly used to observe neutron transmission images. Computers are employed for image processing, computerized tomography and three-dimensional analysis. The major applications of neutron radiography include inspection of neclear fuel; evaluation of material for airplane; observation of fuel in the engine and oil in the hydraulic systems in airplanes; testing of composite materials; etc. (Nogami, K.)

  9. neutron radiography

    International Nuclear Information System (INIS)

    Barton, J.P.

    1993-01-01

    Neutron radiography (or radiology) is a diverse filed that uses neutrons of various energies, subthermal, thermal, epithermal or fast in either steady state or pulsed mode to examine objects for industrial, medical, or other purposes, both microscopic and macroscopic. The applications include engineering design, biological studies, nondestructive inspection and materials evaluation. In the past decade, over 100 different centers in some 30 countries have published reports of pioneering activities using reactors, accelerators and isotopic neutron sources. While film transparency and electronic video are most common imaging methods for static or in motion objects respectively, there are other important data gathering techniques, including track etch, digital gauging and computed tomography. A survey of the world-wide progress shows the field to be gaining steadily in its diversity, its sophistication and its importance. (author)

  10. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  11. High energy neutron radiography

    International Nuclear Information System (INIS)

    Gavron, A.; Morley, K.; Morris, C.; Seestrom, S.; Ullmann, J.; Yates, G.; Zumbro, J.

    1996-01-01

    High-energy spallation neutron sources are now being considered in the US and elsewhere as a replacement for neutron beams produced by reactors. High-energy and high intensity neutron beams, produced by unmoderated spallation sources, open potential new vistas of neutron radiography. The authors discuss the basic advantages and disadvantages of high-energy neutron radiography, and consider some experimental results obtained at the Weapons Neutron Research (WNR) facility at Los Alamos

  12. JRR-3 neutron radiography facility

    International Nuclear Information System (INIS)

    Matsubayashi, M.; Tsuruno, A.

    1992-01-01

    JRR-3 neutron radiography facility consists of thermal neutron radiography facility (TNRF) and cold neutron radiography facility (CNRF). TNRF is installed in JRR-3 reactor building. CNRF is installed in the experimental beam hall adjacent to the reactor building. (author)

  13. Neutron radiography in metallurgy

    International Nuclear Information System (INIS)

    Rant, J.; Ilic, R.

    1977-01-01

    The review surveys microneutronographic and neutron-induced autoradiographic techniques and their applications in metallurgy. A brief survey of applications of neutron radiography as a method of non-destructive testing to some macroscopic problems in metallurgy is included. (author)

  14. Neutron radiography, techniques and applications

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1987-10-01

    After describing the principles of the ''in pool'' and ''dry'' installations, techniques used in neutron radiography are reviewed. Use of converter foils with silver halide films for the direct and transfer methods is described. Advantages of the use of nitrocellulose film for radiographying radioactive objects are discussed. Dynamic imaging is shortly reviewed. Standardization in the field of neutron radiography (ASTM and Euratom Neutron Radiography Working Group) is described. The paper reviews main fields of use of neutron radiography. Possibilities of use of neutron radiography at research reactors in various scientific, industrial and other fields are mentioned. Examples are given of application of neutron radiography in industry and the nuclear field. (author)

  15. Double beam neutron radiography facility

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-09-01

    The DR1 reactor at Risoe is used as a neutron source for neutron radiography. In the double-beam neutron radiography facility a neutron flux of an intensity of 1.4 and 1.8 x 10 6 n. cm -2 . s -1 reaches the object to be radiographed. The transport and exposure container used for neutron radiography of irradiated nuclear fuel rods is described, and the exposure technique and procedure are reviewed. The mode by which single neutron radiographs are assembled and assessed is described. This report will be published in the ''Neutron Radiography Newsletter''. (author)

  16. Neutron radiography in Brazil

    International Nuclear Information System (INIS)

    Rogers, J.D.

    1983-01-01

    Neutron radiography studies being carried out in reactor centres in Brazil are discussed. These research projects are under way using the 5 MW swimming pool reactor at the Institute of Energy and Nuclear Research (IPEN) in Sao Paulo and the Argonaut reactor at the Institute of Nuclear Engineering (IEN) in Rio de Janeiro. (Auth.)

  17. Radiography with polarised neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael L.

    2010-08-20

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni{sub 3}Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T{sub C} on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with

  18. Radiography with polarised neutrons

    International Nuclear Information System (INIS)

    Schulz, Michael L.

    2010-01-01

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd 1-x Ni x and Ni 3 Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd 1-x Ni x and Ni 3 Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni 3 Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T C on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with different ordering temperatures. This

  19. Neutron induced electron radiography

    International Nuclear Information System (INIS)

    Andrade, Marcos Leandro Garcia

    2008-01-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 μm in 24 μm of aluminum at a resolution of 32 μm. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  20. Neutron radiography of Apollo ordnance

    International Nuclear Information System (INIS)

    Golliher, K.G.

    1983-01-01

    Neutron radiography played an important role in the successful Apollo missions. Neutron radiography was used, for the first time, on a production basis to examine the internal details of ordnance devices employed in the Apollo Program. Ordnance devices ranged from charges which separated the massive booster stages to those which triggered the release of re-entry parachutes. Discussed are the early developments in neutron radiography and the conversion of this infant nondestructive technology into production capabilities. (Auth.)

  1. Quantitative neutron radiography using neutron absorbing honeycomb

    International Nuclear Information System (INIS)

    Tamaki, Masayoshi; Oda, Masahiro; Takahashi, Kenji; Ohkubo, Kohei; Tasaka, Kanji; Tsuruno, Akira; Matsubayashi, Masahito.

    1993-01-01

    This investigation concerns quantitative neutron radiography and computed tomography by using a neutron absorbing honeycomb collimator. By setting the neutron absorbing honeycomb collimator between object and imaging system, neutrons scattered in the object were absorbed by the honeycomb material and eliminated before coming to the imaging system, but the neutrons which were transmitted the object without interaction could reach the imaging system. The image by purely transmitted neutrons gives the quantitative information. Two honeycombs were prepared with coating of boron nitride and gadolinium oxide and evaluated for the quantitative application. The relation between the neutron total cross section and the attenuation coefficient confirmed that they were in a fairly good agreement. Application to quantitative computed tomography was also successfully conducted. The new neutron radiography method using the neutron-absorbing honeycomb collimator for the elimination of the scattered neutrons improved remarkably the quantitativeness of the neutron radiography and computed tomography. (author)

  2. Euratom Neutron Radiography Working Group

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    reactor fuel as well as establish standards for radiographic image quality of neutron radiographs. The NRWG meets once a year in each of the neutron radiography centers to review the progress made and draw plans for the future. Besides, ad-hoc sub-groups or. different topics within the field of neutron......In 1979 a Neutron Radiography Working Group (NRWG) was constituted within Buratom with the participation of all centers within the European Community at which neutron facilities were available. The main purpose of NRWG was to standardize methods and procedures used in neutron radiography of nuclear...... radiography are constituted. This paper reviews the activities and achievements of the NRWG and its sub-groups....

  3. Neutron radiography for nondestructive testing

    International Nuclear Information System (INIS)

    John, J.

    1979-01-01

    Neutron radiography is similar to X-ray inspection in that both depend upon use of radiation that penetrates some materials and is absorbed by others to provide a contrast image of conditions not readily available for visual inspection. X-rays are absorbed by dense materials, such as metals, whereas neutrons readily penetrate metals, but are absorbed by materials containing hydrogen. The neutron radiography has been successfully applied to a number of inspection situations. These include the inspection of explosives, advanced composites, adhesively bonded structures and a number of aircraft engine components. With the availability of Californium-252, it has become feasible to construct mobile neutron radiography systems suitable for field use. Such systems have been used for in-situ inspection of flight line aircraft, particularly to locate and measure hidden corrosion

  4. Neutron radiography with ultracold neutrons

    International Nuclear Information System (INIS)

    Bates, J.C.

    1981-01-01

    The neutron transmission factor of very thin films may be low if the neutron energy is comparable to the pseudo-potential of the film material. Surprisingly, perhaps, it is relatively easy to obtain neutrons with such low energies in sufficient numbers to produce neutron radiographs. (orig.)

  5. Radiography using californium-252 neutron sources

    International Nuclear Information System (INIS)

    Ray, J.W.

    1975-01-01

    The current status in the technology of neutron radiography using californium-252 neutron sources is summarized. Major emphasis is on thermal neutron radiography since it has the widest potential applicability at the present time. Attention is given to four major factors which affect the quality and useability of thermal neutron radiography: source neutron thermalization, neutron beam extraction geometry, neutron collimator dimensions, and neutron imaging methods. Each of these factors has a major effect on the quality of the radiographs which are obtained from a californium source neutron radiography system and the exposure times required to obtain the radiographs; radiograph quality and exposure time in turn affect the practicality of neutron radiography for specific nondestructive inspection applications. A brief discussion of fast neutron radiography using californium-252 neutron sources is also included. (U.S.)

  6. New prospect in neutron radiography

    International Nuclear Information System (INIS)

    Cluzeau, S.

    1991-01-01

    Neutron radiography is a very useful non-destructive testing (NDT) method which frequently complements classical X-ray inspection. Numerous inspections in some fields are currently performed at reactor-based neutron radiography facilities but many other interesting applications in different fields are at present not considered because the objects to be tested cannot be moved to a reactor. It is the goal of the DIANE project, to allow the utilization of this NDT method in industrial facilities by developing a safe and convenient neutron radiography equipment using an ''on-off'' neutron source. As a result of the efforts of the four European partners, a first laboratory demonstration model is currently in operation in Germany and a fully mobile second one is expected by the end of 1992. Good radiographs are obtained with exposure times in the range of a few seconds to ten minutes using an electronic imaging system. The fast neutron generator uses a sealed neutron tube delivering 5.10 11 neutrons.cm -2 .s -1 in 4 π steradian; with a collimator ratio of about 12, the fluence rate onto the object is then close to 1,5.10 5 thermal neutrons.cm -2 .s -1 . (author)

  7. TREAT neutron-radiography facility

    International Nuclear Information System (INIS)

    Harrison, L.J.

    1981-01-01

    The TREAT reactor was built as a transient irradiation test reactor. By taking advantage of built-in system features, it was possible to add a neutron-radiography facility. This facility has been used over the years to radiograph a wide variety and large number of preirradiated fuel pins in many different configurations. Eight different specimen handling casks weighing up to 54.4 t (60 T) can be accommodated. Thermal, epithermal, and track-etch radiographs have been taken. Neutron-radiography service can be provided for specimens from other reactor facilities, and the capacity for storing preirradiated specimens also exists

  8. Neutron radiography with the cyclotron

    International Nuclear Information System (INIS)

    Tazawa, Shuichi; Asada, Yorihisa; Yano, Munehiko; Nakanii, Takehiko.

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. This article presents a new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and is equipped with vertical and horizontal irradiation ports. The article describes a series of experiments, we conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained from 9 Be(p, n) reaction and thermalized by elastic scattering process. The article also describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Further, some of practical neutron radiograph examinations of aero-space components and museum art objects of classic bronze mirror and an attempt realizing real time imaging technique, are introduced in the article. (author)

  9. Neutron radiography of fuel pins

    International Nuclear Information System (INIS)

    Jackson, C.N. Jr.; Powers, H.G.; Burgess, C.A.

    1975-01-01

    Neutron radiography performed with a reactor source has been shown to be a superior radiographic method for the examination of unirradiated mixed oxide fuel pins at the Hanford Engineering Development Laboratory. Approximately 1,700 fuel pins were contained in a sample that demonstrated the capability of the method for detecting laminations, structural flaws, fissile density variation, hydrogenous inclusions and voids in assembled fuel pins. The nature, extent, and importance of the detected conditions are substantiated by gamma autoradiography and by destructive analysis employing alpha autoradiography, electron microprobe and visual inspection. Also, a series of radiographs illustrate the response of neutron radiography as compared to low voltage and high voltage x-ray and gamma source Iridium 192 radiography. (U.S.)

  10. Medical radiography with fast neutrons

    International Nuclear Information System (INIS)

    Duehmke, E.

    1980-01-01

    Neutron radiography is important in medicine for two reasons. On the one hand, macroradiographical findings are different from X-ray findings, i.e. new information may be gained on the morphology of humans and animals. On the other hand, there is a direct practical application in the radiotherapy of malignant tumours if one considers the assessment of the growth of malignant processes. Fast neutrons are required for neutron radiographies of biological objects with a diameter of more than 2 cm. In addition sensitive, two-dimensional detectors must be used which are selective for fast neutrons. The book describes the optimisation and sensitisation of a detector using the example of cellulose nitrate foil for fast reactor neutrons. Images of human spinal chords with tumours proved by pathological and anatomical examinations give a better picture of the dimensions of the tumour than comparative X-ray pictures. For examinations of living patients, neutron radiography should be applied only in those tumour-bearing parts of the bodies in which radiation treatment is required for therapeutical purposes anyway. (orig./MG) [de

  11. Neutron detection and radiography

    International Nuclear Information System (INIS)

    Bollen, R.H.; Van Esch, R.F.

    1975-01-01

    An improved method of recording neutron images is described which comprises imagewise irradiating with neutrons an intensifying screen containing a gadolinium compound that fluoresces when struck by x-rays and subjecting the fluorescent light pattern resulting from the impact of the neutrons on the screen onto a photographic material. (auth)

  12. Neutron radiography using neutron imaging plate

    International Nuclear Information System (INIS)

    Chankow, Nares; Wonglee, Sarinrat

    2008-01-01

    Full text: The aims of this research are to study properties of neutron imaging plate, to obtain a suitable condition for neutron radiography and to use the neutron imaging plate for testing of materials nondestructively. The experiments were carried out by using a neutron beam from the Thai Research Reactor TRR-1/M1 at a power of 1.2 MW. A BAS-ND 2040 FUJI neutron imaging plate and a MX125 Kodak X-ray film/Gadolinium neutron converter screen combination were tested for comparison. It was found that the photostimulated light (PSL) read out of the imaging plate was directly proportional to the exposure time. It was also found that radiography with neutron using the imaging plate was approximately 40 times faster than the conventional neutron radiography using x-ray film/Gd converter screen combination. The sensitivity of the imaging plate to gamma-rays was investigated by using gamma-rays from an 192 Ir and a 60 Co radiographic sources. The imaging plate was found to be 5-6 times less sensitive to gamma-rays than a FUJI BAS-MS 2040 gamma-ray imaging plate. Finally, some specimens were selected to be radiographed with neutrons using the imaging plate and the x-ray film/Gd converter screen combination in comparison to x-rays. Parts containing light elements could be clearly observed by the two neutron radiographic techniques. It could be concluded that the image quality from the neutron imaging plate was comparable to the conventional x-ray film/Gd converter screen combination but the exposure time could be approximately reduced by a factor of 40

  13. Neutron radiography by using JSW baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Yojiro

    1995-01-01

    At present, JSW baby cyclotrons are mostly used for the production of the radioisotopes for medical use. The attempt to use this baby cyclotron for neutron radiography began already in 1981. The feasibility of the neutron radiography for the explosives in metallic cases which are used for H1 rockets was investigated. In 1983, it was shown that the neutron radiography by using the baby cyclotron in Muroran Works, Japan Steel Works, Ltd. was able to be carried out as a routine work. Since then, the nondestructive inspection by neutron radiography has been performed for rocket pyrotechnic articles, and contributed to heighten their reliability. Further, the radiography by using fast neutrons was developed and put to practical use for recent large H2 rockets. The JSW baby cyclotron BC 168 which has been used for neutron radiography can accelerate 16 MeV protons or 8 MeV deuterons up to 50 μA. The principle of thermal neutron radiography is the generation of fast neutrons by irradiating a Be target with the proton beam accelerated by a baby cyclotron, the moderation of the fast neutrons, the formation of the thermal neutron flux of uniform distribution with a collimator, the thermal neutron flux hitting the Gd plate in a film cassette through an object, and the exposure of an X-ray film to electrons from the Gd plate. Fast neutron radiography apparatus, and commercial neutron radiography are described. (K.I.)

  14. Application of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Kobayashi, M.; Wada, N.; Sekita, J.; Sanno-cho, Ota-ku, Tokyo, Japan)

    1983-01-01

    The history and the present state of neutron radiography in Japan are reviewed. Three types of neutron sources, namely nuclear reactors, accelerators and radioisotopes are now used. The interests on the application on neutron radiography become greater and greater in the industries, such as atomic energy, aeronautics and space etc. (Auth.)

  15. Neutron radiography at the Risoe National Laboratory

    International Nuclear Information System (INIS)

    Domanus, J.C.; Gade-Nielsen, P.; Knudsen, P.; Olsen, J.

    1981-11-01

    In this report six papers are collected which will be presented at the First World Conference on Neutron Radiography in San Diego, U.S.A., 7 - 10 December 1981. They are preceded by a short description of the activities of Risoe National Laboratory in the field of post-irradiation examination of nuclear fuel. One of the nondestructive methods used for this examination is neutron radiography. In the six conference papers different aspects of neutron radiography performed at Risoe are presented. (author)

  16. Neutron-induced alpha radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2008-01-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the α - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 μm in thickness can be inspected with a spatial resolution of 32 μm. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to β, γ, X-ray and visible light. (author)

  17. A Neutron Radiography System for Field Use

    Science.gov (United States)

    1989-06-01

    provoked a major renewal of interest in neutron radiography because it promises to bring neutron radiography to the workplace , a convenience provided...II I~F I C II i IiH i ii MTL TR 89-52 I-AD A NEUTRON RADIOGRAPHY SYSTEM N FOR FIELD USE e~m JOHN J. ANTAL and ALFRED S. MAROTTA, and LOUIS J. FARESE...COVERED A NEUTRON RADIOGRAPHY SYSTEM FOR FIELD USE Final Report 6. PERFORMING OR1. REPORT NUMBER 7. AUTHOR(s) S. CONTRACT OR GRANT NUMBER(s) John J

  18. Neutron radiography at the HFR Petten

    International Nuclear Information System (INIS)

    Markgraf, J.F.W.

    1990-03-01

    This report contains the five papers on neutron radiography activities at the Petten High Flux Reactor (HFR) presented at the Third World Conference on Neutron Radiography which was held in May 1989 in Osaka, Japan. In addition, a survey on neutron radiography in Europe for industry and research as presented at the SITEF NDT symposium 1989 on European Advances in Non-Destructive Testing, held in Toulouse/France in October 1989 is included. The papers compiled here are concerned with: the neutron radiography services available in Petten; the experience with and applications of neutron radiography at Petten; image evaluation and analysis techniques at Petten; the practical utilization of nitrocellulose film in neutron radiography in Europe; an introduction into the basic principles of neutron radiography; an overview of the neutron radiography facilities in Europe for industry and research; and a survey of typical applications of neutron radiography in industry, research and sciences. It is the intention of this compilation to provide a comprehensive overview of the present Petten activities and European facilities in this young and promising field of non-destructive testing of materials and components from the nuclear and the non-nuclear industries and research organizations, and from the sciences

  19. Electronic imaging applied to neutron radiography

    International Nuclear Information System (INIS)

    Garrett, D.A.; Bracher, D.A.

    1976-01-01

    A commercially - available image intensifier was used with a scan conversion memory and a mobile 252 Cf based neutron radiography system to obtain neutron radiographs on a television monitor in 0.5 minutes to 10.0 minutes

  20. Survey of neutron radiography facilities

    International Nuclear Information System (INIS)

    Imel, G.R.; McClellan, G.G.

    1996-01-01

    A directory of neutron radiography facilities around the world was informally compiled about ten years ago under the auspices of the American Society for Testing and Materials (ASTM), Subcommittee E7.05 (Radiology, Neutron). The work lay dormant for a number of years, but was revived in earnest in the fall of 1995. At that time, letters were mailed to all the facilities with available addresses in the original directory, requesting updated information. Additionally, information was gathered at the Second Topical meeting on neutron Radiography Facility System Design and Beam Characterization (November, 1995, Shonan Village, Japan). A second mailing was sent for final confirmation and updates in January, 1996. About 75% of the information in the directory has now been confirmed by the facility management. This paper presents a summary of the information contained in the facility directory. An electronic version of the directory in Wordperfect 6.1, uuencode, or rtf format is available by sending e-mail to the authors at imel at sign anl.gov or imel at sign baobab.cad.cea.fr. A WWW site for the directory is presently under construction

  1. Neutron radiography at the SCK/CEN

    International Nuclear Information System (INIS)

    Tourwe, H.

    1977-01-01

    Neutron radiography has become in recent years a very important method of nondestructive testing in industry and research. The earliest practical application of neutron radiography has probably been the inspection of highly radioactive material: originally irradiated reactor fuels. Applications then progressed to other nuclear and industrial inspection problems. Neutron radiography and the conventional X-ray or gamma techniques are complementary. Some of the most important application fields of neutron radiography are: the detection of light elements (H, Li, B,...) with a very high scattering of absorption cross section for thermal neutrons; the nondestructive control of fuel before and after irradiation; controls where a distinction has to be made between isotopes of the same element ( 235 U and 238 U, 10 B and 11 B,...) and between components of a similar atomic number (Fe and Zn); the control of materials with a high density; the study of corrosion in closed structures; the control of the homogeneity of foreign materials in alloys,.... (author)

  2. neutron radiography. Report prepared from contributions by members of the MOD Working Party on Neutron Radiography

    International Nuclear Information System (INIS)

    Halmshaw, R.

    1977-03-01

    Radiography with thermal or cold neutrons has some special advantages over X-rays and gamma rays, and some facilities for neutron radiography exist in the Ministry of Defence. This report gives a brief and simple description of the technique, its advantages and disadvantages, and is illustrated with a number of Ordnance applications taken from MOD work, to show examples where neutron radiographs provided extra important information not available from X- or gamma radiography. The facilities available in the UK for neutron radiography are listed. (author)

  3. Monte Carlo code for neutron radiography

    International Nuclear Information System (INIS)

    Milczarek, Jacek J.; Trzcinski, Andrzej; El-Ghany El Abd, Abd; Czachor, Andrzej

    2005-01-01

    The concise Monte Carlo code, MSX, for simulation of neutron radiography images of non-uniform objects is presented. The possibility of modeling the images of objects with continuous spatial distribution of specific isotopes is included. The code can be used for assessment of the scattered neutron component in neutron radiograms

  4. Monte Carlo code for neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Milczarek, Jacek J. [Institute of Atomic Energy, Swierk, 05-400 Otwock (Poland)]. E-mail: jjmilcz@cyf.gov.pl; Trzcinski, Andrzej [Institute for Nuclear Studies, Swierk, 05-400 Otwock (Poland); El-Ghany El Abd, Abd [Institute of Atomic Energy, Swierk, 05-400 Otwock (Poland); Nuclear Research Center, PC 13759, Cairo (Egypt); Czachor, Andrzej [Institute of Atomic Energy, Swierk, 05-400 Otwock (Poland)

    2005-04-21

    The concise Monte Carlo code, MSX, for simulation of neutron radiography images of non-uniform objects is presented. The possibility of modeling the images of objects with continuous spatial distribution of specific isotopes is included. The code can be used for assessment of the scattered neutron component in neutron radiograms.

  5. Cold neutron radiography using low power accelerator

    International Nuclear Information System (INIS)

    Kiyanagi, Yoshiaki; Iwasa, Hirokatu

    1993-01-01

    A cold neutron source which can be adopted at a low power accelerator was studied. Time-of-flight radiography using the cold neutron source was performed. It is suggested that time-of-flight cold neutron radiography has possibility to distinguish the materials more clearly than the traditional film method since large contrast differences can be obtained by using digital data of the neutron intensity at different energies from thermal to cold region. Material will be identified at the same time by this method. (author)

  6. Use of a neutron guide in industrial neutron radiography

    International Nuclear Information System (INIS)

    Zaccheo, M.; Berthon, J.; Uzureau, G.; Laporte, A.

    1983-01-01

    This paper describes the neutron radiography facility associated with the Orphee high flux reactor at the Saclay Nuclear Research Centre. Following a brief background review, the paper deals with: the presentation of the facility, with emphasis on all the mechanical systems involved; description of the control and monitoring console; a non-exhaustive list of the facility's potentialities; the advantages and drawbacks of the use of a neutron guide to carry out industrial neutron radiography. (Auth.)

  7. Current and future neutron radiography standards

    International Nuclear Information System (INIS)

    Brenizer, J.S.

    1999-01-01

    Only two organizations are actively producing standards which are used in neutron radiology (NR): the American Society of Testing and Materials (ASTM) and the International Organization for Standardization (ISO). Six ASTM standards exist that address the neutron radiography method. Two of the ASTM standards have been extensively used world-wide. ISO has a working group which is developing three standards that also address the neutron radiography method. Two of these are currently making their way through the ISO approval system. No ASTM or ISO standards exist for the neutron radioscopic method. Future ASTM standards will address the neutron radioscopic method and neutron radiologic system characterization. It is expected that similar efforts will be undertaken in ISO. Given the relatively small community providing neutron radiologic services, international cooperation and the need for ISO standards will most likely continue to grow.(author)

  8. Neutron Radiography at the RP-10 reactor

    International Nuclear Information System (INIS)

    Hinostrosa, H.; Ravello, Y.; Cornejo, N.; Mendoza, M.; Montoya, M.

    1992-01-01

    The facility of neutron radiography at the RP-10 peruvian research reactor is described. The factor of collimation L/D is 149; the Cadmium ratio for the gold in the inspection's area is 4.5, and the thermal neutrons flux on the sample is 3,14 x 10 6 n/cm 2 s (author). 5 refs. 5 fig

  9. System and apparatus for neutron radiography

    International Nuclear Information System (INIS)

    Whittemore, W.L.

    1991-01-01

    This patent describes a neutron radiography apparatus. It comprises an imaging plane; a neutron moderator having a cavity defining a convergent collimator, the cavity having a base and converging walls of neutron moderating material terminating at an aperture; a divergent collimator coaxially joined to the cavity at the aperture, the divergent collimator having diverging walls of radiation- absorbing material extending from the aperture to an expanded distal opening for irradiating the imaging plane; sources of neutrons disposed symmetrically about the base of the cavity; a neutron moderating material disposed for maximum neutron thermalization between the sources and the base of the cavity; and means for substantially shielding the plane from electromagnetic energy

  10. Liquid metal flow measurement by neutron radiography

    International Nuclear Information System (INIS)

    Takenaka, N.; Ono, A.; Matsubayashi, M.; Tsuruno, A.

    1996-01-01

    Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd 3 ) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.)

  11. Opportunities for TRIGA reactors in neutron radiography

    International Nuclear Information System (INIS)

    Barton, John P.

    1978-01-01

    In this country the two most recent installations of TRIGA reactors have both been for neutron radiography, one at HEDL and the other at ANL. Meanwhile, a major portion of the commercial neutron radiography is performed on a TRIGA fueled reactor at Aerotest. Each of these installations has different primary objectives and some comparative observations can be drawn. Another interesting comparison is between the TRIGA reactors for neutron radiography and other small reactors that are being installed for this purpose such as the MIRENE slow pulse reactors in France, a U-233 fueled reactor for neutron radiography in India and the L88 solution reactor in Denmark. At Monsanto Laboratory, in Ohio, a subcritical reactor based on MTR-type fuel has recently been purchased for neutron radiography. Such systems, when driven by a Van de Graaff neutron source, will be compared with the standard TRIGA reactor. Future demands on TRIGA or competitive systems for neutron radiography are likely to include the pulsing capability of the reactor, and also the extraction of cold neutron beams and resonance energy beams. Experiments recently performed on the Oregon State TRIGA Reactor provide information in each of these categories. A point of particular current concern is a comparison made between the resonance energy beam intensity extracted from the edge of the TRIGA core and from a slot which penetrated to the center of the TREAT reactor. These results indicate that by using such slots on a TRIGA, resonance energy intensities could be extracted that are much higher than previously predicted. (author)

  12. An application of neutron radiography to archaeology

    International Nuclear Information System (INIS)

    Tugrul, B.

    1990-01-01

    Neutron radiography is more useful for certain materials than are the other radiographic techniques. Some neutrons are attenuated by light materials such as water, hydrocarbons and boron, but penetrate through heavy materials such as steel, lead and uranium. The object must be irradiated by neutrons for neutron radiography. The neutron irradiation can take place in a reactor or with a neutron source. The transfer technique relies on the build-up of radioactivity in a foil due to neutron absorption. In this way an activation image is formed in the foil. For this technique, dysprosium ( 164 Dy) and indium ( 115 In) foils can be used. After this irradiation, foils are transferred to a film in the dark-room, the latent image being formed in the film by decay radiation from the foil. The neutron radiography technique has been applied to a sword together with its sheath (inventory number 83/173) (Tugrul and Erdal 1987); a piece of cloth was visible on the handle of the sword. Sword and sheath had become corroded together. The artefact is from the Ikiztepe excavation near the city of Samsun in north Anatolia and belongs to the Early Bronze Age. First, X-ray radiography showed that the sword had been destroyed in large part and was not suitable for conservation and restoration procedures. Second, neutron radiography was carried out. Dysprosium-164 was used for the transfer method as a foil screen and irradiated in the reactor at 100 kW for half an hour. The dysprosium foil remained against the radiographic (Structurix, D-7) film for approximately three half-lives after the irradiation. The neutron radiograph shows the cloth layer continuing towards the bottom of the sheath. Through the cloth, water would have been introduced to the inside of the sheath and this was the main cause of corrosion to the artefact and so of the sword's destruction. (author)

  13. A system for fast neutron radiography

    International Nuclear Information System (INIS)

    Klann, R.T.

    1996-01-01

    A system has been designed and a neutron generator installed to perform fast neutron radiography. With this sytem, objects as small as a coin or as large as a waste drum can be radiographed. The neutron source is an MF Physics A-711 neutron generator which produces 3x10 10 neutrons/second with an average energy of 14.5 MeV. The radiography system uses x-ray scintillation screens and film in commercially available cassettes. The cassettes have been modified to include a thin sheet of plastic to convert neutrons to protons through elastic scattering from hydrogen and other low Z materials in the plastic. For film densities from 1.8 to 3.0, exposures range from 1.9x10 7 to 3.8x10 8 n/cm 2 depending on the type of screen and film

  14. Basic research of neutron radiography using cold neutron beam

    International Nuclear Information System (INIS)

    Oda, Masahiro; Tamaki, Masayoshi; Tasaka, Kanji

    1995-01-01

    As the result of demanding high quality images, now the nuclear reactors which can supply stably intense neutron beam have become the most general neutron source for radiography. For the purpose, mostly thermal neutrons have been used, but it is indispensable to use other neutrons than thermal neutrons for advancing neutron radiography technology and expanding the application fields. The radiography using cold neutrons is most behind in the development because the suitable neutron source was not available in Japan. The neutron sources for exclusively obtaining intense cold neutron beam were installed in the Kyoto University reactor in 1986 and in the JRR-3M of Japan Atomic Energy Research Institute in 1991. Basically as neutron energy lowers, the cross section of substances increases. In certain crystalline substances, the Bragg cutoff arises. The removal of scattered neutrons, the measurement of parallelism of beam and the relation of the thickness of objects with the transmissivity of cold neutrons are described. The imaging by TV method and the cold neutron CT in the CNRF and the simplified neutron CT by film method are reported. (K.I.)

  15. Standardization activities of the Euratom Neutron Radiography Working Group

    International Nuclear Information System (INIS)

    Domanus, J.

    1982-06-01

    In 1979 a working group on neutron radiography was formed at Euratom. The purpose of this group is the standardization of neutron radiographic methods in the field of nuclear fuel. Activities of this Neutron Radiography Working Group are revised. Classification of defects revealed by neutron radiography is illustrated in a special atlas. Beam purity and sensitivity indicators are tested together with a special calibration fuel pin. All the Euratom neutron radiography centers will perform comparative neutron radiography with those items. The measuring results obtained, using various measuring aparatus will form the basis to formulate conclusions about the best measuring methods and instruments to be used in that field. Besides the atlas of neutron radiographic findings in light water reactor fuel, the Euratom Neutron Radiogrphy Working Group has published a neutron radiography handbook in which the neutron radiography installations in the European Community are also described. (author)

  16. The technological development of neutron radiography

    International Nuclear Information System (INIS)

    Garrett, D.A.; Berger, H.

    1977-01-01

    Neutron radiography is a relatively recent technological development in the annals of non-destructive evaluation. It promises to play a role of increasing importance as the technology is further developed. The technique is placed in prospective with regard to other non-destructive evaluation methods in this paper. The history of the development of neutron radiography is traced to the early work of Becker, Bothe and the Joliot-Curies in Europe, and to the work of Chadwick in Great Britain. Details of the experiments which led to the discovery of the neutron by Chadwick in 1932, nuclear properties and energy classifications of neutrons, and the various interactions of neutrons with matter are discussed in detail. A history of neutron radiography is presented which outlines the early experiments by Kallmann and Kuhn; these experiments led to the production of the first neutron radiograph in Germany in 1938. The paper continues with a description of the general techniques that are characteristic of the neutron radiographic process. The breadth and extent of present neutron radiographic technology is discussed as a conclusion of the paper. (author)

  17. Dynamic neutron radiography of a combustion engine

    International Nuclear Information System (INIS)

    Brunner, J.; Hillenbach, A.; Schillinger, B.

    2004-01-01

    Dynamic neutron radiography is a non-destructive testing method, which made big steps in the last years. Depending on the neutron flux, the object and the detector a time resolution down to 50 ms is possible. In the case of repetitive processes the object can be synchronized with the detector and better statistics in the image can be obtained by adding radiographies of the same phase. By delaying the trigger signal a radiography movie can be composed with a time resolution down to 100 μs. A combustion engine is an ideal sample for the explained technique, because the motor block of metal is relatively easy to penetrate, while oil and fuel attenuate the thermal neutron beam much stronger. Various experiments were performed at ILL and PSI. Soon the tomography station ANTARES at FRM-II will be ready for measurements. (author)

  18. Fundamental of neutron radiography and the present of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Sekita, Junichiro

    1988-01-01

    Neutron radiography refers to the application of transmitted neutrons to analysis. In general, thermal neutron is used for neutron radiography. Thermal neutron is easily absorbed by light atoms, including hydrogen, boron and lithium, while it is not easily absorbed by such heavy atoms as tungsten, lead and uranium, permitting detection of impurities in heavy metals. Other neutrons than thermal neutron can also be applied. Cold neutron is produced from fast neutron using a moderator to reduce its energy down to below that of thermal neutron. Cold neutron is usefull for analysis of thick material. Epithermal neutron can induce resonance characteristic of each substance. With a relatively small reaction area, fast neutron permits observation of thick samples. Being electrically neutral, neutrons are difficult to detect by direct means. Thus a substance that releases charged particles is put in the path of neutrons for indirect measurement. X-ray film combined with converter screen for conversion of neutrons to charge particles is placed behind the sample. Photographing is carried out by a procedure similar to X-ray photography. Major institues and laboratories in Japan provided with neutron radiography facilities are listed. (Nogami, K.)

  19. Fail-safe neutron shutter used for thermal neutron radiography

    International Nuclear Information System (INIS)

    Sachs, R.D.; Morris, R.A.

    1976-11-01

    A fail-safe, reliable, easy-to-use neutron shutter was designed, built, and put into operation at the Omega West Reactor, Los Alamos Scientific Laboratory. The neutron shutter will be used primarily to perform thermal neutron radiography, but is also available for a highly collimated source of thermal neutrons [neutron flux = 3.876 x 10 6 (neutrons)/(cm 2 .s)]. Neutron collimator sizes of either 10.16 by 10.16 cm or 10.16 by 30.48 cm are available

  20. Neutron radiography with the cyclotron, 3

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Fujishiro, Masatoshi; Tsujii, Yukio

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. A new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and equipped with vertical and horizontal irradiation ports, is presented in this article. A series of experiment, prior to its construction, was conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained, from 9 Be (p, n) reaction and thermalized by elastic scattering process. This article describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Some of practical neutron radiograph examination of aero-space components and museum art objects of classic bronze mirror are also presented together with an attempt realizing real time imaging technique. (author)

  1. Fast neutron radiography using photoluminescent imaging plates

    International Nuclear Information System (INIS)

    Rant, J.; Kristof, E.; Balasko, M.; Stade, J.

    1999-01-01

    Fast neutron radiography (FNR) and resonance neutron radiography (RNR) are complementary to the conventional radiography with high energy gamma-rays or brems-strahlung radiation used for the inspection of thick metal objects. In both non-destructive methods, the contrast sensitivity and the penetration power can be improved by using higher energy neutrons. At present direct techniques based either n Solid State Nuclear Track detectors (SSNTDs) or scintillating screens and transfer techniques using activation threshold detectors and radiographic films are applied for the detection of fast neutron images. Rather low detection sensitivity of film and SSNTD based fast neutron imaging methods and also rather poor inherent image contrast of SSNTD pose a problem for FNR in the fast neutron energy region 1-15 MeV interesting for NDT. For more efficient detection of fast neutron images the use of novel highly sensitive photoluminescent imaging plates (IP) in combination with threshold at the KFKI research reactor. The conventional IP produced by FUJI Photo Film Co. for the detection of beta and X-ray radiation were used. The threshold activation detectors were the reactions 115 In(n, n') 115m In, 64 Zn(n,p) 64 Cu, 56 Fe(n, p) 56 Mn, 24 Mg(n, p) 24 Na and 27 Al(n, α) 24 Na. These threshold reactions cover the fast neutron energy region between 0,7 MeV and 12 MeV. Pure, commercially available metals 0,1 mm to 0,25 mm thick made of In, Zn, Fe, Mg and Al were used as converter screens. The very high sensitivity of IP, the linearity of their response over 5 decades of exposure dose and the high dynamic digitalisation latitude enabled fast neutron radiography of image quality comparable to the quality of thermal NR. In our experimental conditions (φ n ∼ 10 8 n/cm 2 s, R Cd ∼ 2) the neutron exposure and IP exposure periods were still practical and comparable to the half life of the corresponding reaction products (half an hour to several hours). Even with the 27 Al(n.α) 24

  2. Quantitative analysis of boron by neutron radiography

    International Nuclear Information System (INIS)

    Bayuelken, A.; Boeck, H.; Schachner, H.; Buchberger, T.

    1990-01-01

    The quantitative determination of boron in ores is a long process with chemical analysis techniques. As nuclear techniques like X-ray fluorescence and activation analysis are not applicable for boron, only the neutron radiography technique, using the high neutron absorption cross section of this element, can be applied for quantitative determinations. This paper describes preliminary tests and calibration experiments carried out at a 250 kW TRIGA reactor. (orig.) [de

  3. Neutron radiography devices and their own applications

    International Nuclear Information System (INIS)

    Farny, G.

    1975-04-01

    Three kinds of neutron radiography devices were developed by the Saclay Reactor Department: underwater facilities for active rig or loop examination; extracted beam without γ for industrial applications; a special unit for the examination of spent fuels several meters long from power plants. These devices are described and their applications and performances discussed [fr

  4. Neutron radiography at the Paul Scherrer Institute

    International Nuclear Information System (INIS)

    Pleinert, H.; Lehmann, E.; Hammer, J.

    1994-01-01

    Neutron radiography provides an efficient tool of measurement for many applications in fundamental research as well as in industrial non-destructive testing (NDT). A neutron radiography program has been initiated at the Paul Scherrer Institute and implemented since 1992. From the beginning of 1992 until the end of 1993, a neutron facility has been in operation at the SAPHIR research reactor. Several applications have been tested and programs on two main fields of application have been established, focusing on the study of porous materials, especially concrete and granitic rock. The investigations on concrete and other building materials are carried out in cooperation with the Swiss Federal Institute of Technology in Zurich. The experimental activities are currently carried out at the Atominstitute of the Austrian Universities in Vienna, in the framework of a cooperation program with the Atominstitute. The continuation of the activities on a new radiography facility at the spallation source SINQ is planned at the Paul Scherrer Institute. In the following an overview of the method, of the actual and potential applications of neutron radiography at the Paul Scherrer Institute is given. (author) 6 figs., 1 tab., 3 refs

  5. Assessment of cold neutron radiography capability

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Roberts, J.A.

    1998-01-01

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The authors goals were to demonstrate and assess cold neutron radiography techniques at the Los Alamos Neutron Science Center (LANSCE), Manual Lujan Neutron Scattering Center (Lujan Center), and to investigate potential applications of the capability. The authors have obtained images using film and an amorphous silicon detector. In addition, a new technique they have developed allows neutron radiographs to be made using only a narrow range of neutron energies. Employing this approach and the Bragg cut-off phenomena in certain materials, they have demonstrated material discrimination in radiography. They also demonstrated the imaging of cracks in a sample of a fire-set case that was supplied by Sandia National Laboratory, and they investigated whether the capability could be used to determine the extent of coking in jet engine nozzles. The LANSCE neutron radiography capability appears to have applications in the DOE stockpile maintenance and science-based stockpile stewardship (SBSS) programs, and in industry

  6. Neutron radiography of osteopetrotic rat

    International Nuclear Information System (INIS)

    Graf, B.; Renard, G.; Le Gall, J.; Laporte, A.

    1983-01-01

    The osteopetrotic disease is characterized by bone and cartilage tissue coexistence in the medullary space of long bones. The authors have studied ''congenital osteopetrosis'' of ''op'' rats. Comparing radiography, neutrography and histology, the evolution of the ''osteopetrotic disease'' and the healing of the ill rats by a single injection of bone marrow from normal animals is shown. (Auth.)

  7. Application of neutron radiography to plant research

    International Nuclear Information System (INIS)

    Nakanishi, Tomoko

    1995-01-01

    Neutron radiography was used to image plant roots in soils. Soybeans were used as experimental plants. When the length of the soybean root was 3-5 cm, the plant was transferred to an alminum foil and cultivated by adding polyvinyl alcoholic polymer (polymer A) and pulm-derived polymer (polymer B) as water absorbing polymers to soils. Plant samples were removed sequentially and irradiated with neutrons for 19 seconds at the JRR-3M neutron radiography facility. After irradiation, X-ray film images were obtained to observe water dynamics of roots and soils. Neutron images of soybean roots showed that secondary roots had grown on the side of water absorbing polymer-added soils in the case of polymer A, but on the side of non-added soils in the case of polymer B. When polymer B was added just below the soils where roots were grown, root growth was restricted only to the soil surface, and plant growth condition and dry weight were similar to those in the control plants. Thus the design of root shape may be possible by using polymer B. Similar experiment was made on 5 kinds of trees. Images of cross section of Japanese Cypress revealed that water contained in the tree is not always present along with growth ring of the tree. These findings may have an important implication for the potential application of neutron radiography in plant research. (N.K.)

  8. Visualization of frosting phenomena by using neutron radiography

    International Nuclear Information System (INIS)

    Yoshimura, Tomoya; Matsumoto, Ryosuke; Umekawa, Hisashi; Ami, Takeyuki; Saito, Yasushi

    2012-01-01

    This study focuses on the frost formation on the fin-tube heat exchanger using neutron radiography. The visualization of the frost formation was estimated by the attenuation of the neutron beam through the water. The visualization image of the neutron radiography shows clearly the frost formation phenomena on the fin-tube heat exchanger. The rapid frost formation was observed at the fin and tube edges. Local mass transfer coefficient can be calculated from the differential images of the neutron radiography. (author)

  9. Application of imaging plate neutron detector to neutron radiography

    CERN Document Server

    Fujine, S; Kamata, M; Etoh, M

    1999-01-01

    As an imaging plate neutron detector (IP-ND) has been available for thermal neutron radiography (TNR) which has high resolution, high sensitivity and wide range, some basic characteristics of the IP-ND system were measured at the E-2 facility of the KUR. After basic performances of the IP were studied, images with high quality were obtained at a neutron fluence of 2 to 7x10 sup 8 n cm sup - sup 2. It was found that the IP-ND system with Gd sub 2 O sub 3 as a neutron converter material has a higher sensitivity to gamma-ray than that of a conventional film method. As a successful example, clear radiographs of the flat view for the fuel side plates with boron burnable poison were obtained. An application of the IP-ND system to neutron radiography (NR) is presented in this paper.

  10. Radiography

    Science.gov (United States)

    Gardner, C. G.

    1973-01-01

    Radiography is discussed as a method for nondestructive evaluation of internal flaws of solids. Gamma ray and X-ray equipment are described along with radiographic film, radiograph interpretation, and neutron radiography.

  11. Non destructive testing and neutron radiography in 1994

    International Nuclear Information System (INIS)

    Bayon, G.

    1994-01-01

    Neutron radiography has been considered for a long time as a promising technique; however it plays a minor part in the world of non destructive testing today, due to the lack of suitable neutron sources and lack of new industrial applications. This paper reviews the present status of neutron sources, neutron radiography activities, especially in France (such as the neutron-capture-issued secondary radiation spectrometry), in nuclear, aerospace, aeronautical and metallurgical sectors, and the last applications of neutron dynamic imaging. 9 refs

  12. Radiography and tomography with polarized neutrons

    International Nuclear Information System (INIS)

    Treimer, Wolfgang

    2014-01-01

    Neutron imaging became important when, besides providing impressive radiographic and tomographic images of various objects, physical, quantification of chemical, morphological or other parameters could be derived from 2D or 3D images. The spatial resolution of approximately 50 µm (and less) yields real space images of the bulk of specimens with more than some cm 3 in volume. Thus the physics or chemistry of structures in a sample can be compared with scattering functions obtained e.g. from neutron scattering. The advantages of using neutrons become more pronounced when the neutron spin comes into play. The interaction of neutrons with magnetism is unique due to their low attenuation by matter and because their spin is sensitive to magnetic fields. Magnetic fields, domains and quantum effects such as the Meissner effect and flux trapping can only be visualized and quantified in the bulk of matter by imaging with polarized neutrons. This additional experimental tool is gaining more and more importance. There is a large number of new fields that can be investigated by neutron imaging, not only in physics, but also in geology, archeology, cultural heritage, soil culture, applied material research, magnetism, etc. One of the top applications of polarized neutron imaging is the large field of superconductivity where the Meissner effect and flux pinning can be visualized and quantified. Here we will give a short summary of the results achieved by radiography and tomography with polarized neutrons. - Highlights: • Radiography and tomography with polarized neutrons yield new results concerning the suppressed Meissner effect and magnetic flux trapping. • Suppressed Meissner effect was observed in pure lead samples and niobium. • Trapped magnetic fields in cylindrical Pb samples are squeezed around the rod axis. • The shape and the amount of trapped fields could be determined and quantified

  13. Radiography and tomography with polarized neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Treimer, Wolfgang, E-mail: treimer@helmholtz-berlin.de [University of Applied Sciences, Beuth Hochschule für Technik Berlin, Department Mathematics Physics and Chemistry, Luxemburgerstr. 10, D-13353 Berlin (Germany); Helmholtz Zentrum für Materialien und Energie, Department G – GTOMO, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany)

    2014-01-15

    Neutron imaging became important when, besides providing impressive radiographic and tomographic images of various objects, physical, quantification of chemical, morphological or other parameters could be derived from 2D or 3D images. The spatial resolution of approximately 50 µm (and less) yields real space images of the bulk of specimens with more than some cm{sup 3} in volume. Thus the physics or chemistry of structures in a sample can be compared with scattering functions obtained e.g. from neutron scattering. The advantages of using neutrons become more pronounced when the neutron spin comes into play. The interaction of neutrons with magnetism is unique due to their low attenuation by matter and because their spin is sensitive to magnetic fields. Magnetic fields, domains and quantum effects such as the Meissner effect and flux trapping can only be visualized and quantified in the bulk of matter by imaging with polarized neutrons. This additional experimental tool is gaining more and more importance. There is a large number of new fields that can be investigated by neutron imaging, not only in physics, but also in geology, archeology, cultural heritage, soil culture, applied material research, magnetism, etc. One of the top applications of polarized neutron imaging is the large field of superconductivity where the Meissner effect and flux pinning can be visualized and quantified. Here we will give a short summary of the results achieved by radiography and tomography with polarized neutrons. - Highlights: • Radiography and tomography with polarized neutrons yield new results concerning the suppressed Meissner effect and magnetic flux trapping. • Suppressed Meissner effect was observed in pure lead samples and niobium. • Trapped magnetic fields in cylindrical Pb samples are squeezed around the rod axis. • The shape and the amount of trapped fields could be determined and quantified.

  14. A system for fast neutron radiography

    International Nuclear Information System (INIS)

    Klann, R.T.

    1997-01-01

    A system has been designed and a neutron generator installed to perform fast neutron radiography. With this system, objects as small as a coin and as large as a 19 liter container have been radiographed. The neutron source is an MF Physics A-711 neutron generator which produces 3 x 10[sup 10] neutrons/second with an average energy of 14. 5 MeV. The radiography system uses x-ray scintillation screens and film in commercially available light-tight cassettes. The cassettes have been modified to include a thin sheet of plastic to produce protons from the neutron beam through elastic scattering from hydrogen and other low Z materials in the plastic. For film densities from 1.8 to 3.0, exposures range from 1.9 x 10[sup 7] n/cm[sup 2] to 3.8 x 10[sup 8] n/cm[sup 2] depending on the type of screen and film. The optimum source-to-film distance was found to be 150 cm. At this distance, the geometric unsharpness was determined to be approximately 2.2-2.3 mm and the smallest hole that could be resolved in a 1.25 cm thick sample had a diameter of 0.079 cm

  15. Mathematics and physics of neutron radiography

    International Nuclear Information System (INIS)

    Harms, A.A.; Wyman, D.R.

    1985-01-01

    This book provides detailed descriptions and analyses of selected experiments and their mathematical characterization. Also included are illustrative and quantitative procedures for applications. This book also discusses the radiography, nondestructive testing and nuclear reactor utilization. The contents discussed are: I: Introduction. II: Component Characterization. III: Object-Image Relations. IV: Rectangular Geometry. V: Cylindrical Geometry. VI: Two-Dimensional Analysis. VII: Object Scattering. VIII: Linear Systems Formulation. IX: Selected Topics. X: Neutron Radiographs. XI: Bibliography and References. Subject Index

  16. Proceedings of 7th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Katsurayama, Kousuke; Tsujimoto, Tadashi

    1986-10-01

    The first short period conference on neutron radiography was held in 1970, and now the 7th meeting was held. The works to develop neutron radiography in Japan are as active as those in western countries, and the research is in progress by using neutrons from reactors, radioisotopes and accelerators in order to achieve the technology of high standard. In this conference, 26 papers and six comments were presented, and the themes covered the equipment for radiography, the practical application, and the related research. The second World Conference on Neutron Radiography will be held in Paris in June, 1986, and the further promotion of the spread of neutron radiography can be expected. The proceedings of the conference is published with the hope that joint effort and information exchange are further enhanced in coming years to develop the neutron radiography in Japan. The neutron radiography using the Kinki University reactor, the Rikkyo Triga-2 reactor, the Musashi reactor, the Kyoto research reactor, a 3MV Van de Graaff accelerator in Toyota, a subcompact cyclotron in Sumitomo, a baby cyclotron-dual collimator in National Space Development Agency and so on, Cf-252 based thermal neutron radiography, CT with Sb-124/Be neutrons, pulse power neutron source, imaging converters, neutron radiographic image processing, computed tomography using neutron television systems and others are reported. (Kako, I.)

  17. New development of neutron radiography with a small cyclotron

    International Nuclear Information System (INIS)

    Ikeda, Yasushi; Ohkubo, Kohei; Kato, Toshihiko; Nakamura, Tomihisa; Fuji, Takayoshi.

    1990-01-01

    A series of neutron radiography testing has been performed for several years by using a small accelerator called 'Baby Cyclotron' manufactured by Japan Steel Works, Ltd. The Baby Cyclotron produces fast neutrons at the rate of 4x10 12 n/cm 2 s, and enables to perform neutron radiography imaging by various techniques. The most important application of this Baby Cyclotron radiography system is the non-destructive testing (NDT) of various explosive devices prepared for space launch vehicles. It is assured that thermal neutron radiography testing is a very useful means for the NDT. Also fast neutron radiography testing is in progress. The fast neutron radiography with a CR39 track-etch image recorder was developed, and it was shown to be the very useful NDT means when the thicker objects used for new H-2 launch vehicles had to be examined. Because thermal neutron radiography has the high detectability of hydrogenous materials, organic elastomers such as O-rings and explosive powder are clearly observable through the opaque steel walls of containers. The Baby Cyclotron and the neutron radiography facility, thermal neutron and fast neutron radiography testings and so on are reported. (K.I.)

  18. Neutron radiography working group test programme

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1989-03-01

    Scope and results of the Euratom Neutron Radiography Working Group Test Program are described. Seven NR centers from six European Community countries have performed this investigation using eleven NR facilities. Four test items were neutron radiographed using 30 different film/converter combinations. From film density measurements neutron beam components were determined. Radiographic sensitivity was assessed from visual examinations of the radiographs. About 25,000 dimensional measurements were made and were used for the assessment of accuracies of dimensional measurements from neutron radiographs. The report gives a description of the test items used for the Test Program, the film density and dimensional measurements, and concentrates on the assessment of the measuring results. The usefulness of the beam purity and sensitivity indicators was assessed with the conclusion that they are not suitable for neutron radiography of nuclear reactor fuel. Ample information is included in the report about measuring accuracies which can be reached in dimensional measurements of fuel pins. After a general comparison of measuring accuracies is discussed. Results from different NR facilities are treated separately as are the different kinds of dimensions of the fuel pins. Finally human and instrument factors are discussed. After presenting final conclusions (which take into account the above-mentioned factors) results of other investigations about dimensional measurements are shortly reviewed

  19. Visualization of multiphase flow by neutron radiography

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Takenaka, Nobuyuki.

    1991-01-01

    Neutron radiography (NRG) is a technique which produces images of the internal structure of a body, making use of the attenuation characteristics of neutrons in the materials being observed. Recently, attempts have been made to expand the application of this technique not only to non-destructive testing but also to a variety of industrial and basic research fields. The attenuation of neutrons is large in a light material like water and small in ordinary metals, which difference may make it possible to visualize a multiphase flow in a metallic container. Particularly, the neutron television, which is one of the applied techniques of NRG, is expected to be a useful tool for observing the behavior of two-phase flow, since it produces images in real time. In this paper the basic idea and the method of NRG are presented along with examples of visualization of multiphase flow by NRG. (author)

  20. Neutron radiography using a transportable superconducting cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Allen, D.A. (School of Physics and Space Research, University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Hawkesworth, M.R. (School of Physics and Space Research, University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Beynon, T.D. (School of Physics and Space Research, University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Green, S. (School of Physics and Space Research, University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Rogers, J.D. (Rolls-Royce, Derby (United Kingdom)); Allen, M.J. (Rolls-Royce, Derby (United Kingdom)); Plummer, H.C. (Rolls-Royce, MatEval, Derby (United Kingdom)); Boulding, N.J. (Oxford Instruments (United Kingdom)); Cox, M. (Oxford Instruments (United Kingdom)); McDougall, I. (Oxford Instruments (United Kingdom))

    1994-12-30

    A thermal neutron radiography system based on a compact 12 MeV superconducting proton cyclotron is described. Neutrons are generated using a thick beryllium target and moderated in high density polyethylene. Monte Carlo computer simulations have been used to model the neutron and photon transport in order to optimise the performance of the system. With proton beam currents in excess of 100 [mu]A, it can provide high thermal neutron fluxes with L/D ratios of between 50 and 300 for various applications. Both film and electronic imaging are used to produce radiographs. The electronic imaging system consists of a [sup 6]Li-loaded ZnS intensifier screen, and a low light CCD or SIT camera. High resolution images can be recorded and computer-controlled data processing, analysis and display are possible. ((orig.))

  1. A study of television imaging system for fast neutron radiography

    International Nuclear Information System (INIS)

    Yoshii, Koji

    1992-01-01

    The neutron radiography with fast neutron beam is a very useful imaging technique for thicker objects, especially those composed of hydrogen-rich materials which are sometimes difficult to image by thermal neutron radiography. The fast neutron radiography has not been studied so much as the thermal neutron radiography. The fast neutron radiography has been studied at the fast neutron source reactor 'Yayoi' of the University of Tokyo built in Tokai-mura. The average neutron energy of the Yayoi is about 1 MeV, and the peak neutron flux at the core center is 0.8 x 10 12 at the maximum operating power of 2 kW. In the experiment on fast neutron radiography, a CR39 nuclear track detector has been used successfully. But in the Yayoi radiography procedure, about 24 hours were required for obtaining an imaging result. To get a prompt imaging result and a real-time imaging result, it is necessary to develop a fast neutron television system, and in this paper, a new fast neutron TV system is proposed. The main difference is the converter material sensitive to fast neutrons. The study on the fast neutron TV system was carried out by using the Baby Cyclotron of Japan Steel Works, and the good images were realized. (K.I.)

  2. Proceeding of 6th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Katsurayama, Kohsuke; Hiraoka, Eiichi; Tsujimoto, Tadashi

    1984-01-01

    The 6th short conference on neutron radiography was held on August 30 and 31, 1983, at the Research Reactor Institute, Kyoto niversity, as a part of the joint research program of the Institute. During the period since the first meeting in November, 1970, steady development was made in both research and practical use of neutron radiography in Japan owing to the persistent effort of the persons concerned. In the conference, 70 persons participated, and 21 papers were presented. The problems treated were the apparatuses of neutron television, neutron radiography and neutron photography, the various application of neutron radiography, the standard of neutron radiography and others. The high value of neutron radiography and the increasing demand to use this technique were shown in this meeting. Considering the recent rapid development of new technology, it is expected that neutron radiography will find the wide varieties of application in the near future. The proceedings of the conference are published by collecting the gists of papers, hoping to enhance joint effort and the exchange of information to develop neutron radiography. (Kako, I.)

  3. Study of a transportable neutron radiography system

    International Nuclear Information System (INIS)

    Souza, S.N.A. de.

    1991-05-01

    This work presents a study a transportable neutron radiography system for a 185 GBq 241 Am-Be (α, η) source with a neutron yield roughly 1,25 x 10 7 n/s. Studies about moderation, collimation and shielding are showed. In these studies, a calculation using Transport Theory was carried out by means of transport codes ANISN and DOT (3.5). Objectives were: to obtain a maximum and more homogeneous thermal neutron flux in the collimator outlet to the image plain, and an adequate radiation shielding to attend radiological protection rules. With the presented collimator, it was possible to obtain for the thermal neutron flux, at the collimator outlet and next to the image plain, a L/D ratio of 14, for neutron fluxes up to 4,09 x 10 2 n.cm -2 .s -1 . Considering the low intensity of the source, it is a good value. Studies have also been carried out for L/D ratios of 22 and 30, giving thermal neutron fluxes at the image plain of 1,27 x 10 2 n.cm -2 .s -1 and 2,65 x 10 2 n.cm -2 .s -1 , respectively. (author). 30 refs, 39 figs, 9 tabs

  4. Void fraction measurements using neutron radiography

    International Nuclear Information System (INIS)

    Glickstein, S.S.; Vance, W.H.; Joo, H.

    1992-01-01

    Real-time neutron radiography is being evaluated for studying the dynamic behavior of two phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. To simulate vapor conditions encountered in a fluid flow duct, an air-water flow system was constructed. Air was injected into the bottom of the duct at flow rates up to 0.47 I/s (1 cfm). The water flow rate was varied between 0--3.78 I/m (0--1 gpm). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10 6 n/cm 2 /s directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5 cm (2 in.) thick aluminum support plates placed on both sides of the duct wall. Image analysis techniques were employed to extract void fractions from the data which was recorded on videotape. This consisted of time averaging 256 video frames and measuring the gray level distribution throughout the region. The distribution of the measured void fraction across the duct was determined for various air/water mixtures. Details of the results of experiments for a variety of air and water flow conditions are presented

  5. Discrete tomography in neutron radiography

    International Nuclear Information System (INIS)

    Kuba, Attila; Rodek, Lajos; Kiss, Zoltan; Rusko, Laszlo; Nagy, Antal; Balasko, Marton

    2005-01-01

    Discrete tomography (DT) is an imaging technique for reconstructing discrete images from their projections using the knowledge that the object to be reconstructed contains only a few homogeneous materials characterized by known discrete absorption values. One of the main reasons for applying DT is that we will hopefully require relatively few projections. Using discreteness and some a priori information (such as an approximate shape of the object) we can apply two DT methods in neutron imaging by reducing the problem to an optimization task. The first method is a special one because it is only suitable if the object is composed of cylinders and sphere shapes. The second method is a general one in the sense that it can be used for reconstructing objects of any shape. Software was developed and physical experiments performed in order to investigate the effects of several reconstruction parameters: the number of projections, noise levels, and complexity of the object to be reconstructed. We give a summary of the experimental results and make a comparison of the results obtained using a classical reconstruction technique (FBP). The programs we developed are available in our DT reconstruction program package DIRECT

  6. New north beam tube for the neutron radiography reactor

    International Nuclear Information System (INIS)

    Pruett, D.P.; Richards, W.J.; Heidel, C.C.

    1982-01-01

    Neutron radiography of the fuel undergoing examination in the argon cell is performed in the NRAD Facility and is one of many examinations performed on the fuel. The reactor and examination procedure are described. The new radiography system, developed to expand the present radiography capabilities to radiograph both irradiated and unirradiated specimens and to provide for the development of new radiography techniques without interfering with the argon cell production schedule is presented

  7. Neutron induced electron radiography; Radiografia com eletrons induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Leandro Garcia

    2008-07-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 {mu}m in 24 {mu}m of aluminum at a resolution of 32 {mu}m. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  8. Beam Characterization at the Neutron Radiography Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sarah Morgan; Jeffrey King

    2013-01-01

    The quality of a neutron imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam’s effective length-to-diameter ratio, neutron flux profile, energy spectrum, image quality, and beam divergence, is vital for producing quality radiographic images. This project characterized the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam’s effective length-to-diameter ratio and image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. Improvement of the existing NRAD MCNP beamline model includes validation of the model’s energy spectrum and the development of enhanced image simulation methods. The image simulation methods predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in an MCNP beamline model.

  9. Neutron radiography in Indian space programme

    International Nuclear Information System (INIS)

    Viswanathan, K.

    1999-01-01

    Pyrotechnic devices are indispensable in any space programme to perform such critical operations as ignition, stage separation, solar panel deployment, etc. The nature of design and configuration of different types of pyrotechnic devices, and the type of materials that are put in their construction make the inspection of them with thermal neutrons more favourable than any other non destructive testing methods. Although many types of neutron sources are available for use, generally the radiographic quality/exposure duration and cost of source run in opposite directions even after four decades of research and development. But in the area of space activity, by suitably combining the X-ray and neutron radiographic requirements, the inspection of the components can be made economically viable. This is demonstrated in the Indian space programme by establishing a 15 MeV linear accelerator based neutron generator facility to inspect medium to giant solid propellant boosters by X-ray inspection and all types of critical pyro and some electronic components by neutron radiography. Since the beam contains unacceptable gamma, transfer imaging technique has been evolved and the various parameters have been optimised to get a good quality image

  10. Neutron radiography at the HFR Petten compilation of HFR Petten contributions to the second world conference on neutron radiography

    International Nuclear Information System (INIS)

    Markgraf, J.W.F.

    1986-01-01

    This booklet summarizes the six papers on neutron radiography activities at the Petten High Flux Reactor (HFR), presented at the Second World Conference on neutron radiography, held in June 1986 in Paris, France. The conference was organized by the French CEA and COFREND, and JRC Petten, HFR Division, with joint sponsorship of the national societies on Non-Destructive Testing (NDT) from the Federal Republic of Germany, United Kingdom, Japan and the United States. The Petten papers are concerned with: (i) the work of the Neutron Radiography Working Group (NRWG), an expert group operating under the auspices of the Commission of the European Communities represented by JRC Petten, HFR Division; (ii) applications of neutron radiography in research programmes performed at HFR; (iii) neutron radiography facilities at HFR; and (iv) image evaluation techniques

  11. Basic research for developing the quantitative neutron radiography

    International Nuclear Information System (INIS)

    Tamaki, Masayoshi; Ikeda, Yasushi; Ohkubo, Kohei; Tasaka, Kanji; Yoneda, Kenji; Fujine, Shigenori.

    1992-01-01

    This investigation concerns the basic research and development on quantitative neutron radiography by using a honeycomb collimator which reduces the effect due to scattered neutrons in objective matter. On the observation of the hydrogenate materials such as metal hydrides, water and hydrocarbons by neutron radiography, scattered neutrons from these objectives make the quantitativeness of the neutron radiographic image lower grade. In order to improve the quantitativeness of the image, a honeycomb collimator, which is a honeycomb structure of neutron absorbing material, was introduced to the conventional neutron radiography system. By setting the neutron-absorbing honeycomb collimator between objective and imaging system, neutrons scattered in the objective were absorbed by the honeycomb material and attenuated before coming to the imaging system, but neutrons which were transmitted the objective sample without any interaction reached the imaging system and formed the image of the sample. As the image by purely transmitted neutrons is intrinsic due to the neutronic character of the sample, the image data give the quantitative information. In the present experiment, aluminum honeycomb which was coated with boron nitride was prepared and used in order to image the standard stepwise samples for the evaluation of the quantitative grade of the newly proposed neutron radiography method. From the comparison between macroscopic total cross section and the attenuation coefficient of the thermal neutron for aluminum, copper and hydrocarbons, it was confirmed that they were fairly consistent each other. It can be concluded that the newly proposed neutron radiography method using the neutron-absorbing honeycomb collimator for the elimination of the scattered neutrons improves remarkably the quantitativeness of the neutron radiography technique. (author)

  12. An improved fast neutron radiography quantitative measurement method

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito; Hibiki, Takashi; Mishima, Kaichiro; Yoshii, Koji; Okamoto, Koji

    2004-01-01

    The validity of a fast neutron radiography quantification method, the Σ-scaling method, which was originally proposed for thermal neutron radiography was examined with Monte Carlo calculations and experiments conducted at the YAYOI fast neutron source reactor. Water and copper were selected as comparative samples for a thermal neutron radiography case and a dense object, respectively. Although different characteristics on effective macroscopic cross-sections were implied by the simulation, the Σ-scaled experimental results with the fission neutron spectrum cross-sections were well fitted to the measurements for both the water and copper samples. This indicates that the Σ-scaling method could be successfully adopted for quantitative measurements in fast neutron radiography

  13. Recent advances in fast neutron radiography for cargo inspection

    International Nuclear Information System (INIS)

    Sowerby, B.D.; Tickner, J.R.

    2007-01-01

    Fast neutron radiography techniques are attractive for screening cargo for contraband such as narcotics and explosives. Neutrons have the required penetration, they interact with matter in a manner complementary to X-rays and they can be used to determine elemental composition. Compared to neutron interrogation techniques that measure secondary radiation (neutron or gamma-rays), neutron radiography systems are much more efficient and rapid and they are much more amenable to imaging. However, for neutron techniques to be successfully applied to cargo screening, they must demonstrate significant advantages over well-established X-ray techniques. This paper reviews recent developments and applications of fast neutron radiography for cargo inspection. These developments include a fast neutron and gamma-ray radiography system that utilizes a 14 MeV neutron generator as well as fast neutron resonance radiography systems that use variable energy quasi-monoenergetic neutrons and pulsed broad energy neutron beams. These systems will be discussed and compared with particular emphasis on user requirements, sources, detector systems, imaging ability and performance

  14. Neutron radiography inspection of investment castings

    International Nuclear Information System (INIS)

    Richards, W.J.; Barrett, J.R.; Springgate, M.E.; Shields, K.C.

    2004-01-01

    Investment casting, also known as the lost wax process, is a manufacturing method employed to produce near net shape metal articles. Traditionally, investment casting has been used to produce structural titanium castings for aero-engine applications with wall thickness less than 1 in (2.54 cm). Recently, airframe manufacturers have been exploring the use of titanium investment casting to replace components traditionally produced from forgings. Use of titanium investment castings for these applications reduces weight, cost, lead time, and part count. Recently, the investment casting process has been selected to produce fracture critical structural titanium airframe components. These airframe components have pushed the traditional inspection techniques to their physical limits due to cross sections on the order of 3 in (7.6 cm). To overcome these inspection limitations, a process incorporating neutron radiography (n-ray) has been developed. In this process, the facecoat of the investment casting mold material contains a cocalcined mixture of yttrium oxide and gadolinium oxide. The presence of the gadolinium oxide, allows for neutron radiographic imaging (and eventual removal and repair) of mold facecoat inclusions that remain within these thick cross sectional castings. Probability of detection (POD) studies have shown a 3x improvement of detecting a 0.050x0.007 in 2 (1.270x0.178 mm 2 ) inclusion of this cocalcined material using n-ray techniques when compared to the POD using traditional X-ray techniques. Further, it has been shown that this n-ray compatible mold facecoat material produces titanium castings of equal metallurgical quality when compared to the traditional materials. Since investment castings can be very large and heavy, the neutron radiography facilities at the University of California, Davis McClellan Nuclear Radiation Center (UCD/MNRC) were used to develop the inspection techniques. The UCD/MNRC has very unique facilities that can handle large parts

  15. Fast and epithermal neutron radiography using neutron irradiator

    International Nuclear Information System (INIS)

    Oliveira, Karol A.M. de; Crispim, Verginia R.; Ferreira, Francisco J.O.

    2013-01-01

    The neutron radiography technique (NR) with neutrons in the energy range fast to epithermal is a powerful tool used in no-destructive inspection of bulky objects of diverse materials, including those rich in hydrogen, oxygen, nitrogen ad carbon. Thus, it can be used to identify, inclusions, voids and thickness differences in materials such as explosive artifacts and narcotics. Aiming at using NR with fast and epithermal neutrons, an Irradiator was constructed by: a 241 Am-Be source, with 5 Ci activity, a collimator with adjustable collimation rate, L/D; and a shield device composed by plates of borated paraffin and iron. The test specimens chosen were a Beam Purity Indicator (BPI) and an Indicator of Visual Resolution (IVR). The neutron radiography images obtained had a resolution of 444.4 μm and 363.6 μm respectively when registered in: 1) the sheet of the nuclear track solid detector, CR-39 type, through X (n,p) Y nuclear reaction; and 2) Kodak Industrex M radiographic film plate in close contact with a boron converter screen, both stored in a Kodak radiographic cassette. (author)

  16. Digital image processing in neutron radiography

    International Nuclear Information System (INIS)

    Koerner, S.

    2000-11-01

    Neutron radiography is a method for the visualization of the macroscopic inner-structure and material distributions of various samples. The basic experimental arrangement consists of a neutron source, a collimator functioning as beam formatting assembly and of a plane position sensitive integrating detector. The object is placed between the collimator exit and the detector, which records a two dimensional image. This image contains information about the composition and structure of the sample-interior, as a result of the interaction of neutrons by penetrating matter. Due to rapid developments of detector and computer technology as well as deployments in the field of digital image processing, new technologies are nowadays available which have the potential to improve the performance of neutron radiographic investigations enormously. Therefore, the aim of this work was to develop a state-of-the art digital imaging device, suitable for the two neutron radiography stations located at the 250 kW TRIGA Mark II reactor at the Atominstitut der Oesterreichischen Universitaeten and furthermore, to identify and develop two and three dimensional digital image processing methods suitable for neutron radiographic and tomographic applications, and to implement and optimize them within data processing strategies. The first step was the development of a new imaging device fulfilling the requirements of a high reproducibility, easy handling, high spatial resolution, a large dynamic range, high efficiency and a good linearity. The detector output should be inherently digitized. The key components of the detector system selected on the basis of these requirements consist of a neutron sensitive scintillator screen, a CCD-camera and a mirror to reflect the light emitted by the scintillator to the CCD-camera. This detector design enables to place the camera out of the direct neutron beam. The whole assembly is placed in a light shielded aluminum box. The camera is controlled by a

  17. Digital image processing in neutron radiography

    International Nuclear Information System (INIS)

    Koerner, S.

    2000-11-01

    Neutron radiography is a method for the visualization of the macroscopic inner-structure and material distributions of various materials. The basic experimental arrangement consists of a neutron source, a collimator functioning as beam formatting assembly and of a plane position sensitive integrating detector. The object is placed between the collimator exit and the detector, which records a two dimensional image. This image contains information about the composition and structure of the sample-interior, as a result of the interaction of neutrons by penetrating matter. Due to rapid developments of detector and computer technology as well as deployments in the field of digital image processing, new technologies are nowadays available which have the potential to improve the performance of neutron radiographic investigations enormously. Therefore, the aim of this work was to develop a state-of-the art digital imaging device, suitable for the two neutron radiography stations located at the 250 kW TRIGA Mark II reactor at the Atominstitut der Oesterreichischen Universitaeten and furthermore, to identify and develop two and three dimensional digital image processing methods suitable for neutron radiographic and tomographic applications, and to implement and optimize them within data processing strategies. The first step was the development of a new imaging device fulfilling the requirements of a high reproducibility, easy handling, high spatial resolution, a large dynamic range, high efficiency and a good linearity. The detector output should be inherently digitized. The key components of the detector system selected on the basis of these requirements consist of a neutron sensitive scintillator screen, a CCD-camera and a mirror to reflect the light emitted by the scintillator to the CCD-camera. This detector design enables to place the camera out of the direct neutron beam. The whole assembly is placed in a light shielded aluminum box. The camera is controlled by a

  18. Time-grated energy-selected cold neutron radiography

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Brun, T.O.; Claytor, T.N.; Farnum, E.H.; Greene, G.L.; Morris, C.

    1998-01-01

    A technique is under development at the Los Alamos Neutron Science Center (LANSCE), Manuel Lujan Jr. Neutron Scattering Center (Lujan Center) for producing neutron radiography using only a narrow energy range of cold neutrons. The technique, referred to as Time-Gated Energy-Selected (TGES) neutron radiography, employs the pulsed neutron source at the Lujan Center with time of flight to obtain a neutron pulse having an energy distribution that is a function of the arrival time at the imager. The radiograph is formed on a short persistence scintillator and a gated, intensified, cooled CCD camera is employed to record the images, which are produced at the specific neutron energy range determined by the camera gate. The technique has been used to achieve a degree of material discrimination in radiographic images. For some materials, such as beryllium and carbon, at energies above the Bragg cutoff the neutron scattering cross section is relatively high while at energies below the Bragg cutoff the scattering cross section drops significantly. This difference in scattering characteristics can be recorded in the TGES radiography and, because the Bragg cutoff occurs at different energy levels for various materials, the approach can be used to differentiate among these materials. This paper outlines the TGES radiography technique and shows an example of radiography using the approach

  19. The neutron radiography unit at Washington State University

    International Nuclear Information System (INIS)

    Ogren, J.W.; Burkhart, D.; Hinman, G.

    1972-01-01

    The WSU neutron radiography unit was developed as a student project, but more recently it has been used by our College of Engineering Research Division in a study of mine wall reinforcement by plastic materials

  20. High speed motion neutron radiography of two-phase flow

    International Nuclear Information System (INIS)

    Robinson, A.H.; Wang, S.L.

    1983-01-01

    Current research in the area of two-phase flow utilizes a wide variety of sensing devices, but some limitations exist on the information which can be obtained. Neutron radiography is a feasible alternative to ''see'' the two-phase flow. A system to perform neutron radiographic analysis of dynamic events which occur on the order of several milliseconds has been developed at Oregon State University. Two different methods have been used to radiograph the simulated two-phase flow. These are pulsed, or ''flash'' radiography, and high speed movie neutron radiography. The pulsed method serves as a ''snap-shot'' with an exposure time ranging from 10 to 20 milliseconds. In high speed movie radiography, a scintillator is used to convert neutrons into light which is enhanced by an optical intensifier and then photographed by a high speed camera. Both types of radiography utilize the pulsing capability of the OSU TRIGA reactor. The principle difficulty with this type of neutron radiography is the fogging of the image due to the large amount of scattering in the water. This difficulty can be overcome by using thin regions for the two-phase flow or using heavy water instead of light water. The results obtained in this paper demonstrate the feasibility of using neutron radiography to obtain data in two-phase flow situations. Both movies and flash radiographs have been obtained of air bubbles in water and boiling from a heater element. The neutron radiographs of the boiling element show both nucleate boiling and film boiling. (Auth.)

  1. Neutron radiography on the research reactor IEA-R1

    International Nuclear Information System (INIS)

    Fuga, R.

    1984-01-01

    The neutron radiography device is composed of a conical neutron collimator, having a 1/250 collimation ratio, an object chamber and an irradiation cassete. Each component on the system is described and some representative results are presented. Selected examples of the potentialities of this technique are given. (Author) [pt

  2. Neutron radiography for quality assurance of PHWR fuel pins

    International Nuclear Information System (INIS)

    Chandrasekharan, K.N.; Patil, B.P.; Ghosh, J.K.; Ganguly, C.

    1993-01-01

    Neutron radiography was employed for quality assurance (QA) for advanced PHWR experimental fuel pins containing mixed uranium-plutonium dioxide and thorium-plutonium dioxide pellets. Direct, transfer and track-etch techniques were utilised. The thermal neutron beam facility of APSARA research reactor at Bhabha Atomic Research Centre was used. (author). 5 refs., 16 figs., 2 tabs

  3. Progress and status of neutron radiography and gauging in Europe

    International Nuclear Information System (INIS)

    Balasko, Marton

    1996-01-01

    European neutron radiography (NR) stations, applications and main trends of progress are surveyed. NR laboratories installed at research reactors operating in eight countries. DIANE transportable neutron source has been constructed within the framework of EURECA project. High resolution film techniques and video imaging are used in various applications. In several cases NR is combined with other non-destructive methods. The European Neutron Radiography Working Group organizes annual meetings and international projects (COST, INCO Copernicus) to promote personal contacts and scientific cooperation in this field. (author)

  4. Study of a Loop Heat Pipe Using Neutron Radiography

    International Nuclear Information System (INIS)

    C. Thomas Conroy; A. A. El-Ganayni; David R. Riley; John M. Cimbala; Jack S. Brenizer, Jr.; Abel Po-Ya Chuang; Shane Hanna

    2001-01-01

    An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design

  5. Imaging of Rabbit VX-2 Hepatic Cancer by Cold and Thermal Neutron Radiography

    Science.gov (United States)

    Tsuchiya, Yoshinori; Matsubayashi, Masahito; Takeda, Tohoru; Lwin, Thet Thet; Wu, Jin; Yoneyama, Akio; Matsumura, Akira; Hori, Tomiei; Itai, Yuji

    2003-11-01

    Neutron radiography is based on differences in neutron mass attenuation coefficients among the elements and is a non-destructive imaging method. To investigate biomedical applications of neutron radiography, imaging of rabbit VX-2 liver cancer was performed using thermal and cold neutron radiography with a neutron imaging plate. Hepatic vessels and VX-2 tumor were clearly observed by neutron radiography, especially by cold neutron imaging. The image contrast of this modality was better than that of absorption-contrast X-ray radiography.

  6. Dynamic neutron radiography instrumentation and applications in Central Europe

    International Nuclear Information System (INIS)

    Balasko, M.

    1996-01-01

    Characteristic features of simultaneous dynamic neutron and gamma radiography installations built in the last ten years at the Budapest/Hungary and at the Seibersdorf/Austria research reactors are surveyed. For image detection scintillation detectors and a low-light level television camera with video output are used, thereby providing the possibility for visualizing medium speed movements inside the investigated object. The radiography stations have been used for inspecting industrial products, with the aim of research and development. (orig.)

  7. Non-destructive testing of rocket fuse by thermal neutron radiography

    International Nuclear Information System (INIS)

    An Fulin; Li Furong

    1999-01-01

    A neutron radiography system in reactor horizontal hole of Tsinghua University was introduced, and its capability of neutron radiography was evaluated by theory and experiment, the non-destructive testing for rocket fuse is successful

  8. Recommended practice for the neutron radiography of nuclear fuels

    International Nuclear Information System (INIS)

    Matfield, R.S.

    1983-01-01

    The document is part of a Neutron Radiography Handbook being prepared by a Neutron Radiography Working Party of the European Community. It commences with a description of the information that should be provided by a user of neutron radiography services and then gives recommendations on the equipment to be used. This is followed by two sections on the techniques to be used for detecting discontinuities and the making of measurements on nuclear fuel. This is then followed by recommended safety practices and then sections on film handling, film processing, viewing of radiographs, references, radiographs, storage and records. Recommendations on training and certification are being prepared. It does not include any technical justification for the practices which are recommended. (Auth.)

  9. Television imaging system for fast neutron radiography using baby cyclotron

    International Nuclear Information System (INIS)

    Yoshii, Koji; Miya, Kenzo; Katoh, Norihiko.

    1993-01-01

    A television imaging system for fast neutron radiography (FNR-TV) developed using the fast neutron source reactor YAYOI was applied to the baby-cyclotron based fast neutron source to get images of thick objects quickly. In the system the same technique as a current television imaging system of thermal neutron radiography was applied, while the luminescent converter was used to detect fast neutrons. Using the CR39 track etch method it took about 7 h to get an image, while the FNR-TV only 20 s enough for taking the same object. However the FNR-TV imaging result of the simulation model of a large explosive device for the space launch vehicle of H-2 type was not so good as the image taken with the CR39 track etch method. The reason was that the luminescence intensity of the FNR-TV converter was a quarter of that in the YAYOI. (author)

  10. Californium Multiplier. Part I. Design for neutron radiography

    International Nuclear Information System (INIS)

    Crosbie, K.L.; Preskitt, C.A.; John, J.; Hastings, J.D.

    1982-01-01

    The Californium Multiplier (CFX) is a subcritical assembly of enriched uranium surrounding a californium-252 neutron source. The function of the CFX is to multiply the neutrons emitted by the source to a number sufficient for neutron radiography. The CFX is designed to provide a collimated beam of thermal neutrons from which the gamma radiation is filtered, and the scattered neutrons are reduced to make it suitable for high resolution radiography. The entire system has inherent safety features, which provide for system and personnel safety, and it operates at moderate cost. In Part I, the CFX and the theory of its operation are described in detail. Part II covers the performance of the Mound Facility CFX

  11. Neutron radiography of thick hydrogenous materials with use of an imaging plate neutron detector

    International Nuclear Information System (INIS)

    Kato, K.; Matsumoto, G.; Karasawa, Y.; Niimura, N.; Matsubayashi, M.; Tsuruno, A.

    1996-01-01

    The value of the neutron mass attenuation coefficient of hydrogen being very high, it is extremely difficult to image normal size, living animals with neutron radiography. However, the authors suggest the possibility of applying neutron radiography for biomedical specimens. The organs in the breast, bones and cartilages in the extremities, and the tail of mice and rats were clearly imaged by neutron radiography with Gd foils as neutron converters and X-ray films. However, no contours of the organs in the mouse abdomen were visible with neutron radiography with an exposure time of 200 s. By adding Gd or Li compounds as neutron converters to imaging X-ray plates, imaging plates have been developed for neutron detectors. A trial using these imaging plates for neutron radiography of water-filled containers and the abdomen of mice was completed. The roundness of a 100 ml-beaker was imaged with a neutron exposure of 180 s. Obscure contours of the liver and kidneys of the mouse were imaged with a neutron exposure of 100 s. (orig.)

  12. Testing the durability of concrete with neutron radiography

    International Nuclear Information System (INIS)

    Beer, F.C. de; Le Roux, J.J.; Kearsley, E.P.

    2005-01-01

    The ability of concrete to withstand the penetration of liquid and oxygen can be described as the durability of concrete. The durability of concrete, can in turn, be quantified by certain characteristics of the concrete such as the porosity, sorptivity and permeability. The quantification of neutron radiography images of concrete structures and, therefore, the determination of concrete characteristics validate conventional measurements. This study compares the neutron radiography capability to obtain quantitative data for porosity and sorptivity in concrete to laboratory or conventional measurements. The effects that water to cement ratio and curing time have on the durability of concrete are investigated

  13. Determination Of Simulated Pellet To Pellet Gap Using Neutron Radiography

    International Nuclear Information System (INIS)

    Kusnowo, A.

    1996-01-01

    The defect on the irradiated fuel element could be detected using neutron radiography. The defect could occurred in pellet to pellet gap, cladding, or even cladding to pellet gap. An investigations has been performed to detect pellet to pellet gap defect that might occur in an irradiated fuel element. An Al foil of 0,1; 0,2; 0,3; und 0,4 mm was inserted between pellets to simulate various pellet to pellet gap. The neutron radiography used had power of 700 kW. The result showed that this simulation represented well enough problems that irradiated fuel element may experience

  14. NECTAR-A fission neutron radiography and tomography facility

    International Nuclear Information System (INIS)

    Buecherl, T.; Lierse von Gostomski, Ch.; Breitkreutz, H.; Jungwirth, M.; Wagner, F.M.

    2011-01-01

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  15. NECTAR-A fission neutron radiography and tomography facility

    Energy Technology Data Exchange (ETDEWEB)

    Buecherl, T., E-mail: thomas.buecherl@radiochemie.de [Technische Universitaet Muenchen, Lehrstuhl fuer Radiochemie (RCM), Walther-Meissner-Str. 3, 85748 Garching (Germany); Lierse von Gostomski, Ch. [Technische Universitaet Muenchen, Lehrstuhl fuer Radiochemie (RCM), Walther-Meissner-Str. 3, 85748 Garching (Germany); Breitkreutz, H.; Jungwirth, M.; Wagner, F.M. [Technische Universitaet Muenchen, Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) (Germany)

    2011-09-21

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  16. NECTAR—A fission neutron radiography and tomography facility

    Science.gov (United States)

    Bücherl, T.; Lierse von Gostomski, Ch.; Breitkreutz, H.; Jungwirth, M.; Wagner, F. M.

    2011-09-01

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/ D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  17. Applications of image plates in neutron radiography and neutron diffraction at BARC, Trombay

    International Nuclear Information System (INIS)

    Shaikh, A.M.

    2013-01-01

    Neutron radiography techniques based on Gd, Dy and In metallic foils and X-ray film have been used at this centre since early seventies for various NDT and R and D work in nuclear, defence and aerospace industries. In recent years use of photostimulated luminescence based phosphor imaging plate has been introduced in our work. This has enabled to achieve higher sensitivities and dynamic ranges of recording radiographs with acceptable spatial resolution. It also provides digital image information which is more convenient for quantitative evaluations. Neutron image plates have been used in variety of radiography techniques such as conventional neutron radiography (NR), neutron induced beta radiography (NIBR), hydrogen sensitive epithermal neutron radiography (HYSEN) and for neutron powder diffractometry using Apsara, CIRUS and Dhruva reactors as neutron sources. Recently the image plates have also been used for characterization of thermalized neutron beam from a plasma focus neutron source and recording neutron radiographs. Prior to the utilization image plates have been characterised for their performance. Details of the measurements and applications will be presented. (author)

  18. Radiography and tomography using fission neutrons at FRM-II

    International Nuclear Information System (INIS)

    Buecherl, T.; Lierse von Gostomski, Ch.

    2004-01-01

    Fission neutrons offer complementary information in radiography and tomography compared to the well established techniques using X-rays, gamma-rays, thermal or cold neutrons. They penetrate thick layers of high density materials with only little attenuation, while for light, specially for hydrogen containing materials, their attenuation is high. In the past, fast neutrons for NDT (non-destructive testing) were only available at accelerator driven systems. These high energy neutrons have to be moderated to achieve acceptable detection efficiencies thus drastically reducing the available neutron intensities and either resulting in a high beam divergence or in additional losses in neutron intensities due to beam collimation. The recently installed neutron computerized tomography and radiography system NECTAR at the Forschungsreaktor Muenchen-II (FRM-II) overcomes these disadvantages by using fission neutrons of about 1.7 MeV mean energy created in two converter plates set-up of highly enriched uranium. The beam quality, i.e. the neutron divergence can be adapted to the object to be measured by using different collimators, resulting in L/D-values up to 300. The available neutron beam intensity at the measuring position is up to 1.7E+08 cm -2 s -1 for a maximum beam area of 40 cm x 40 cm. For conventional imaging a two-dimensional detector system based on a CCD-camera is used, other more specialised systems are available. (author)

  19. Radiography and tomography using fission neutrons at FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Buecherl, T.; Lierse von Gostomski, Ch. [Inst. fuer Radiochemie, TU-Muenchen, Garching (Germany)

    2004-07-01

    Fission neutrons offer complementary information in radiography and tomography compared to the well established techniques using X-rays, gamma-rays, thermal or cold neutrons. They penetrate thick layers of high density materials with only little attenuation, while for light, specially for hydrogen containing materials, their attenuation is high. In the past, fast neutrons for NDT (non-destructive testing) were only available at accelerator driven systems. These high energy neutrons have to be moderated to achieve acceptable detection efficiencies thus drastically reducing the available neutron intensities and either resulting in a high beam divergence or in additional losses in neutron intensities due to beam collimation. The recently installed neutron computerized tomography and radiography system NECTAR at the Forschungsreaktor Muenchen-II (FRM-II) overcomes these disadvantages by using fission neutrons of about 1.7 MeV mean energy created in two converter plates set-up of highly enriched uranium. The beam quality, i.e. the neutron divergence can be adapted to the object to be measured by using different collimators, resulting in L/D-values up to 300. The available neutron beam intensity at the measuring position is up to 1.7E+08 cm{sup -2} s{sup -1} for a maximum beam area of 40 cm x 40 cm. For conventional imaging a two-dimensional detector system based on a CCD-camera is used, other more specialised systems are available. (author)

  20. Advancement of neutron radiography technique in JRR-3M

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito

    1999-01-01

    The JRR-3M thermal neutron radiography facility (JRR-3M TNRF) was completed in the JRR-3M of the Japan Atomic Energy Research Institute in 1991 and has been utilized as research tools for various kinds of research fields such as thermal hydraulic researches, agricultural researches, medical researches, archaeological researches and so on. High performance of the JRR-3M TNRF such as high neutron flux, high collimator ratio and wide radiographing field has enabled advanced researches and stimulated developments of advanced neutron radiography (NR) systems for higher spatial resolution and for higher temporal resolution. Static NR systems using neutron imaging plates or cooled CCD camera with high spatial resolution, a real-time NR system using a silicon intensifier target tube camera and a high-frame-rate NR system using a combination of an image intensifier and a high speed digital video camera with high temporal resolution have been developed to fill the requirements from researchers. (author)

  1. Neutron radiography (NRAD) reactor 64-element core upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA (registered) (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The interim critical configuration developed during the core upgrade, which contains only 62 fuel elements, has been evaluated as an acceptable benchmark experiment. The final 64-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (approximately ±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  2. Neutron radiography of heated high-performance mortar

    Directory of Open Access Journals (Sweden)

    Weber B.

    2013-09-01

    Full Text Available Neutron radiography was applied to investigate the water distribution in mortar samples heated from one side to 600 °C. In mortar, aggregates and anhydrous cement are almost transparent to neutrons, while hydration products and water-filled capillary pores bear the largest attenuation. The evolution of the moisture profile shows a sharp dehydration front and accumulation of water due to condensation of water vapor behind this front.

  3. Measurement of Soot Deposition in Automotive Components Using Neutron Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Zekveld, David; Liu, Liaohui [AMEC NSS, 700 University Ave, Toronto, Ontario, M5G 1X6 (Canada); UOIT, 2000 Simcoe Street North, Oshawa, Ontario, L1H 7K4 (Canada); Harrison, Andrew; Gill, Spencer; Harvel, Glenn [UOIT, 2000 Simcoe Street North, Oshawa, Ontario, L1H 7K4 (Canada); Chang, Jen-Shih [McMaster University, 1280 Main Street West, Hamilton, Ontario, L8S 4L8 (Canada)

    2008-07-01

    About 40% of air pollution is generated by vehicles and transportation. The particulate matter (PM) emission significantly impacts human health. Fine particles below 2.5 {mu}m (PM2.5) can enter the lungs and lead to respiratory problems. These particles not only influence human health, but also reduce the capability of many automobile exhaust heat exchanging devices. Neutron radiography is a non-destructive method of analyzing carbonaceous PM. While neutron radiography has been demonstrated for soot measurement in the past, the application has not considered the presence of unburned hydrocarbons, significant amounts of moisture nor examined complex geometrical configurations. The purpose of this work is to study a reliable non-destructive testing methodology using neutron radiography for measurement of soot distribution in automotive components. A soot standard (aluminium target) was designed and manufactured as a calibration tool. The standard is radiographed and used to measure the differences between various soot thickness and compositions. The radiograph images are analyzed to determine a calibration curve based upon the composition of the materials which can then be used for analysis of the automotive components. Experiments are performed using a diesel engine to produce soot deposits on exhaust piping. Soot distribution on exhaust piping is measured using neutron radiography. (authors)

  4. Neutron and gamma radiography with a research reactor

    International Nuclear Information System (INIS)

    Reijonen, Heikki

    1973-01-01

    The thesis consists of eight publications, which describe the instrumental analysis of both neutron and γ-radiography. The emphasis is on various research applications, especially solidification and segregation in Sn-Cd and Sn-In alloys. (L.M.K.)

  5. Radiography with neutrons: use in inspection of hydrogenated materials

    International Nuclear Information System (INIS)

    Pugliesi, R.; Assuncao, M.P.M.

    1989-01-01

    Neutron radiography technique is used for showing the viability of inspecting hydrogenated materials. The experimental disposition is installed in irradiation radial channel n. 10 from IEA-R1 (IPEN-CNEN-SP). The inspetionated materials were munitions for gun and rifle. (C.G.C.)

  6. Measurement of Soot Deposition in Automotive Components Using Neutron Radiography

    International Nuclear Information System (INIS)

    Zekveld, David; Liu, Liaohui; Harrison, Andrew; Gill, Spencer; Harvel, Glenn; Chang, Jen-Shih

    2008-01-01

    About 40% of air pollution is generated by vehicles and transportation. The particulate matter (PM) emission significantly impacts human health. Fine particles below 2.5 μm (PM2.5) can enter the lungs and lead to respiratory problems. These particles not only influence human health, but also reduce the capability of many automobile exhaust heat exchanging devices. Neutron radiography is a non-destructive method of analyzing carbonaceous PM. While neutron radiography has been demonstrated for soot measurement in the past, the application has not considered the presence of unburned hydrocarbons, significant amounts of moisture nor examined complex geometrical configurations. The purpose of this work is to study a reliable non-destructive testing methodology using neutron radiography for measurement of soot distribution in automotive components. A soot standard (aluminium target) was designed and manufactured as a calibration tool. The standard is radiographed and used to measure the differences between various soot thickness and compositions. The radiograph images are analyzed to determine a calibration curve based upon the composition of the materials which can then be used for analysis of the automotive components. Experiments are performed using a diesel engine to produce soot deposits on exhaust piping. Soot distribution on exhaust piping is measured using neutron radiography. (authors)

  7. Practical Uses of Neutron Radiography for Non-Destructive Testing

    International Nuclear Information System (INIS)

    Middleton, M.F.; de Beer, F.; Pazsit, Imre; Li, Kewen; Hilson, Jodie

    2006-01-01

    Over the past nine years, a research collaboration has been developed around the use of neutron radiography in non-destructive testing of porous rocks and other materials. This paper is a review of that work, with a critical reflection on the future potential of the technique. Neutrons are ideal for detecting water concentration, due to the high attenuation of neutrons by hydrogen, in porous or semi-porous media. Problems, which involve the determination of water concentration in porous media, are particularly amenable for neutron radiography analysis. In this context, water concentration in porous media is important in groundwater studies, petroleum reservoir studies, studies of geothermal systems, the understanding of water absorption in building materials, and more recently in mineral exploration and processing applications. Beyond these applications, neutron analysis of flawed and corroded aircraft parts has emerged as a valuable tool to support conventional non-destructive testing (NDT) techniques. Such investigations, using neutron radiography of aircraft parts, have been active in the United States, Canada and South Africa for over two decades. In 2001, an Australian Research Council (ARC) grant enabled the informal collaboration to establish a semi-portable neutron imaging system in Australia. Preliminary results of that ongoing research will also be presented herein. In overview, neutron radiography presents a powerful non-destructive testing method, which in many new areas of application remains to be evaluated. It has proven to be most valuable where water detection, in quantities greater than approximately 0.1 percent of the total volume, is required. This concentration is not a limitation on the technique, but only current applications. It has been demonstrated to be powerful tool to detect natural substances containing bound-water and neutron-attenuating minerals, such as clay, Glauconite and the various water-rich iron-bearing minerals (e.g. Goethite

  8. High Brightness Neutron Source for Radiography. Final report

    International Nuclear Information System (INIS)

    Cremer, J.T.; Piestrup, Melvin A.; Gary, Charles K.; Harris, Jack L.; Williams, David J.; Jones, Glenn E.; Vainionpaa, J.H.; Fuller, Michael J.; Rothbart, George H.; Kwan, J.W.; Ludewigt, B.A.; Gough, R.A.; Reijonen, Jani; Leung, Ka-Ngo

    2008-01-01

    This research and development program was designed to improve nondestructive evaluation of large mechanical objects by providing both fast and thermal neutron sources for radiography. Neutron radiography permits inspection inside objects that x-rays cannot penetrate and permits imaging of corrosion and cracks in low-density materials. Discovering of fatigue cracks and corrosion in piping without the necessity of insulation removal is possible. Neutron radiography sources can provide for the nondestructive testing interests of commercial and military aircraft, public utilities and petrochemical organizations. Three neutron prototype neutron generators were designed and fabricated based on original research done at the Lawrence Berkeley National Laboratory (LBNL). The research and development of these generators was successfully continued by LBNL and Adelphi Technology Inc. under this STTR. The original design goals of high neutron yield and generator robustness have been achieved, using new technology developed under this grant. In one prototype generator, the fast neutron yield and brightness was roughly 10 times larger than previously marketed neutron generators using the same deuterium-deuterium reaction. In another generator, we integrate a moderator with a fast neutron source, resulting in a high brightness thermal neutron generator. The moderator acts as both conventional moderator and mechanical and electrical support structure for the generator and effectively mimics a nuclear reactor. In addition to the new prototype generators, an entirely new plasma ion source for neutron production was developed. First developed by LBNL, this source uses a spiral antenna to more efficiently couple the RF radiation into the plasma, reducing the required gas pressure so that the generator head can be completely sealed, permitting the possible use of tritium gas. This also permits the generator to use the deuterium-tritium reaction to produce 14-MeV neutrons with increases

  9. Applications of neutron radiography for the nuclear power industry

    Energy Technology Data Exchange (ETDEWEB)

    Craft, Aaron E.; Barton, John P.

    2016-11-01

    The World Conference on Neutron Radiography (WCNR) and International Topical Meeting on Neutron Radiography (ITMNR) series have been running over 35 years. The most recent event, ITMNR-8, focused on industrial applications and was the first time this series was hosted in China. In China, more than twenty new nuclear power plants are in construction and plans have been announced to increase the nuclear capacity further by a factor of three within fifteen years. There are additional prospects in many other nations. Neutron tests were vital during previous developments of materials and components for nuclear power applications, as reported in this conference series. For example a majority of the 140 papers in the Proceedings of the First WCNR are for the benefit of the nuclear power industry. Included are reviews of the diverse techniques being applied in Europe, Japan, the United States, and at many other centers. Many of those techniques are being utilized and advanced to the present time. Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Applications include examination of nuclear waste, nuclear fuels, cladding, control elements, and other critical components. In this paper, the techniques developed and applied internationally for the nuclear power industry since the earliest years are reviewed, and the question is asked whether neutron test techniques can be of value in development of the present and future generations of nuclear power plants world-wide.

  10. Characterization of a focusing parabolic guide using neutron radiography method

    International Nuclear Information System (INIS)

    Kardjilov, Nikolay; Boeni, Peter; Hilger, Andre; Strobl, Markus; Treimer, Wolfgang

    2005-01-01

    The aim of the investigation was to test the focusing properties of a new type of focusing neutron guide (trumpet) with parabolically shaped walls. The guide has a length of 431mm with an entrance area of 16x16mm 2 and an output area of 4x4mm 2 . The interior surfaces were coated with a supermirror-surface m=3 and due to their parabolic shape it was expected that an incident parallel beam can be focused in the focal point of the parabolas. To prove this statement the neutron intensity distribution at different distances behind the guide was recorded by means of a standard, high-resolution radiography detector. The experiments were performed at the V12b instrument at HMI with different levels of beam monochromatization demonstrating maximum intensity gains of about 25. The consideration for using the focusing guide for the purposes of cold neutron radiography will be presented

  11. Development of fast neutron radiography system based on portable neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Chia Jia, E-mail: gei-i-kani@hotmail.com; Nilsuwankosit, Sunchai, E-mail: sunchai.n@chula.ac.th [Department of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, Phayathai Rd., Patumwan, Bangkok, THAILAND 10330 (Thailand)

    2016-01-22

    Due to the high installation cost, the safety concern and the immobility of the research reactors, the neutron radiography system based on portable neutron generator is proposed. Since the neutrons generated from a portable neutron generator are mostly the fast neutrons, the system is emphasized on using the fast neutrons for the purpose of conducting the radiography. In order to suppress the influence of X-ray produced by the neutron generator, a combination of a shielding material sandwiched between two identical imaging plates is used. A binary XOR operation is then applied for combining the information from the imaging plates. The raw images obtained confirm that the X-ray really has a large effect and that XOR operation can help enhance the effect of the neutrons.

  12. A neutron radiography facility on the IRT-2000 reactor

    International Nuclear Information System (INIS)

    Khadduri, I.Y.

    1976-01-01

    A neutron radiography facility has been constructed on the thermal neutron channel of the IRT-2000 reactor. A collimated thermal neutron beam exposure area of 10 cm diameter is obtained with an L/D ratio of 48.8. The film used is cellulose nitrate coated with lithium tetraborate which is insensitive to gamma and beta radiation. Some pictures with good contrast and resolution have been obtained. Pictures of parts of an IRT-2000 reactor fuel pin have also been recorded. (orig) [de

  13. High speed motion neutron radiography of dynamic events

    International Nuclear Information System (INIS)

    Robinson, A.H.; Barton, J.P.

    1983-01-01

    The development of a technique that permits neutron radiographic analysis of dynamic processes over a period lasting from one to ten milliseconds is described. The key to the technique is the use of a neutron pulse broad enough to span the duration of a brief event and intense enough to allow recording of the results on a high-speed movie film at frame rates of 10,000 frames/sec. Some typical application results in ballistic studies and two-phase flow are shown and discussed. The use of scintillator screens in the high-speed motion neutron radiography system is summarized and the statistical limitations of the technique are discussed

  14. Pilot experimental study on continual spectrum thermal neutron in-line phase contrast radiography

    International Nuclear Information System (INIS)

    Tang Bin; Huo Heyong; Wu Yang

    2009-01-01

    The in-line phase contrast radiography is one of phase contrast imaging methods. The neutron in-line phase contrast is developed with X-rays phase contrast radiography. In the paper, the principle of in-line phase contrast is introduced briefly and the experimental result of thermal neutron in-line contrast at SPRR-300 is analysed. It shows that thermal neutron can be used as in-line phase contrast radiography and enhances the edge of some sample in radiography and complements the disadvantage of conventional neutron radiography. (authors)

  15. Development of mild steel exposure chart for neutron radiography application

    International Nuclear Information System (INIS)

    Hafizal Yazid; Rafhayudi Jamro; Hishamuddin Husain; Muhammad Rawi Mohd Zin; Razali Kassim; Abd Aziz Mohamed; Azali Muhammad

    2004-01-01

    A neutron radiography exposure chart for mild steel was developed to facilitate the determination of exposure time when producing neutron radiographs for any given mild steel thickness. A mild steel sample in the form of step wedge (1-10 mm thick) was exposed to thermal neutron using Direct technique. This technique involves exposing x-ray film-Gadolinium converter housed in one film cassette simultaneously to thermal neutron beam. Gadolinium converters with thickness of 0.025 mm and 0.5 mm were used to observe the effect of converter thickness on radiographic density and exposure time. Collected radiographic density data is then calculated based on manufacturer's film characteristic chart and finally exposure chart for mild steel was plotted. This chart could later be used as a guide for estimating exposure time for any given sample thickness providing other conditions are similar (material, film processing, neutron flux, film density and converter thickness). (Author)

  16. Effective source size as related to 252Cf neutron radiography

    International Nuclear Information System (INIS)

    Wada, Nobuo; Enomoto, Shigemasa; Tachikawa, Noboru; Nojiri, Toshiaki.

    1977-01-01

    The effective source size in 252 Cf thermal neutron radiography, relating to its geometrical unsharpness in image formation, is experimentally studied. A neutron radiographic system consists of a 160 μg 252 Cf neutron source, water moderator and divergent cadmium lined collimator. Thermal neutron image detection is performed with using a LiF scintillator and a high speed X-ray film to employ direct exposure method. The modulation transfer function, used for describing image quality, is derived from radiographic image corresponding to a cadmium plate with sharp edge. The modulation transfer function for the system is expressed by the product of the function for both geometrical and inherent unsharpness, and allows isolation of geometrical unsharpness as related to the effective size of the thermal neutron source. It is found to be 80 -- 90% of the collimator inlet diameter. (auth.)

  17. Lubricant distribution determination by neutron radiography

    International Nuclear Information System (INIS)

    Stewart, P.A.E.

    1979-01-01

    Cold neutron radiation of energy less than 0.025 eV having a flux greater than 1 x 10 3 neutrons/square centimeter/second is used to diagnose temporal information about the spatial distribution of hydrocarbon fuel and lubrication oils in internal combustion engines, gas turbine engines and fuel systems. Images of the movement of fuel or oil are recorded by directing a beam of neutrons through an engine and using an image intensifier responsive to low light levels to intensify an image formed by neutrons which have been directed through the engine onto a fluorescent screen. The output image from the intensifier is recorded by a video or cine camera

  18. Neutron radiography in Indian space programme

    CERN Document Server

    Viswanathan, K

    1999-01-01

    Pyrotechnic devices are indispensable in any space programme to perform such critical operations as ignition, stage separation, solar panel deployment, etc. The nature of design and configuration of different types of pyrotechnic devices, and the type of materials that are put in their construction make the inspection of them with thermal neutrons more favourable than any other non destructive testing methods. Although many types of neutron sources are available for use, generally the radiographic quality/exposure duration and cost of source run in opposite directions even after four decades of research and development. But in the area of space activity, by suitably combining the X-ray and neutron radiographic requirements, the inspection of the components can be made economically viable. This is demonstrated in the Indian space programme by establishing a 15 MeV linear accelerator based neutron generator facility to inspect medium to giant solid propellant boosters by X-ray inspection and all types of critic...

  19. High-speed motion neutron radiography

    International Nuclear Information System (INIS)

    Bossi, R.H.; Barton, J.P.; Robinson, A.H.

    1982-01-01

    A system has been developed to perform neutron radiographic analysis of dynamic events having a duration of several milliseconds. The system has been operated in the range of 2000 to 10,000 frames. Synchronization has provided high-speed motion neutron radiographs for evaluation of the firing cycles of 7.62-mm munition rounds within a thick steel rifle barrel. The system has also been used to demonstrate its ability to produce neutron radiographic movies of two-phase flow. The equipment includes a TRIGA reactor capable of pulsing to a peak power of 3000 MW, a neutron beam collimator, a scintillator neutron conversion screen coupled to an image intensifier, and a 16-mm high-speed movie camera. The peak neutron flux incident at the object position is about 4 X 10 11 n/cm 2 X s with a pulse, full-width at half-maximum, of 9 ms. Modulation transfer function techniques have been used to assist optimization of the system performance. Special studies have been performed on the scintillator conversion screens and on the effects of statistical limitations on information availability

  20. Gap's dimensions in fuel elements from neutron radiography

    International Nuclear Information System (INIS)

    Notea, A.; Segal, Y.; Trichter, F.

    1985-01-01

    Quantitative Nondestructive evaluation (QNDE) is of upmost importance in the design and manufacture of nuclear fuel elements. Accurate non-destructive measurements of gaps, cracks, displacements, etc. supply vital information for optimizing fuel manufacturing. Neutron radiography is a powerful NDT method for examining spent fuel elements. However, it turned out that the extraction of dimensions, especially in the submillimetric range is questionable. In this paper neutron radiography of pellet-to-pellet gaps in fuel elements is modelled and two procedures for dimension extraction are presented. It is shown that for a wide gap the dimension is preferable, extracted from the width of the film profile, while for narrow gaps it is preferable to extract it from the maximum of the density profile

  1. Application of neutron radiography to restoration of an excavated sword

    International Nuclear Information System (INIS)

    Masuzawa, Fumitake; Murata, Tadashige; Ozaki, Makoto

    1992-01-01

    An excavated sword had turned to fragments of corrosion covered with grit and rust. There are two holes at the pommel and the guard which have elaborate inner walls. The original sword must have had the pommel and the guard, whose shapes had been the same as those of the holes. What were materials of them? Why have they disappeared to have changed into holes? No key which answers these questions has been gotten with macrography and X-ray radiography. Then neutron radiography was tried to examine that. Images which were not recognized on X-ray radiographs appeared on neutron ones. Above-mentioned questions were solved by investigation of them. This paper describes that the sword were well conserved and restored on the basis of it. (author)

  2. Study of corrosion in aluminium using neutron radiography technique

    International Nuclear Information System (INIS)

    Islam, M.N.; Alam, M.K.; Saklayen, M.A.; Ahsan, M.H.; Islam, S.M.A.; Zaman, M.A.

    2000-01-01

    Neutron radiography technique has been adopted for detection of corrosion in aluminium by filling artificially made holes on aluminium slab with Al(OH) 3 . The contrast between the optical densities of corrosion products and aluminium slab was assessed from the densitometric measurements. Variation of optical density difference with sample thickness has also been studied. The results confirm that approximately 0.039 mm thick corrosion products having diameter 10 mm can easily be detected in 2 cm thick aluminium slab. The linear attenuation coefficient of Al(OH) 3 has been obtained as 0.9447. From the present investigation it is confirmed that film neutron radiography (NR) technique is helpful for investigation of Al(OH) 3 type corrosion product in aluminium. (author)

  3. Preliminary examination of the applicability of imaging plates to fast neutron radiography

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito; Hibiki, Takashi; Mishima, Kaichiro; Yoshii, Koji; Okamoto, Koji

    2001-01-01

    Fast neutron radiography is an attractive non-destructive inspection technique because of the excellent penetration characteristics of fast neutrons in matter. However, the difficulty of detecting fast neutrons reduces this attractive feature. As an experiment to overcome the difficulty, imaging plates were applied to fast neutron radiography. A simple combination of two sheets of imaging plates and a sheet of polyethylene as a proton emitter was examined with the (fast neutron, thermal neutron and gamma ray) FTG discriminator proposed by Yoneda et al. . The experimental results showed that the method could be applicable to fast neutron radiography with effective discrimination of γ-rays

  4. Neutron radiography at the Institut de Maintenance Aeronautique

    International Nuclear Information System (INIS)

    Cluzeau, S.

    1999-01-01

    Recently the French Institut de Maintenance Aeronautique (IMA) decided to open a new field of research specially devoted to the inspection methods that should be used by the aircraft overhauling industry. Taking into account its proved ability for an early corrosion detection, neutron radiography (NR) was selected as an inspection method to be appraised. This paper presents the approach that IMA intends to follow for achieving this objective and involving selection of equipment, design of the facility and research program.(author)

  5. Fast neutron radiography of extended biological and medical objects

    International Nuclear Information System (INIS)

    Duehmke, E.; Greim, L.

    1978-01-01

    The fast neutron radiography enables us to image extended objects and yields quite different pictures than conventional roentgenograms. Using foils of cellulose nitrate and the track etching technique a γ-ray-insensitive detector is available providing sufficient imaging qualities. One of the biological neutrograms shown in the paper is of special importance because one can see a malignant tumor of the columna vertebralis. This finding was not detectable by roentgenological examination. (orig.) [de

  6. Average Soil Water Retention Curves Measured by Neutron Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Chu-Lin [ORNL; Perfect, Edmund [University of Tennessee, Knoxville (UTK); Kang, Misun [ORNL; Voisin, Sophie [ORNL; Bilheux, Hassina Z [ORNL; Horita, Juske [Texas Tech University (TTU); Hussey, Dan [NIST Center for Neutron Research (NCRN), Gaithersburg, MD

    2011-01-01

    Water retention curves are essential for understanding the hydrologic behavior of partially-saturated porous media and modeling flow transport processes within the vadose zone. In this paper we report direct measurements of the main drying and wetting branches of the average water retention function obtained using 2-dimensional neutron radiography. Flint sand columns were saturated with water and then drained under quasi-equilibrium conditions using a hanging water column setup. Digital images (2048 x 2048 pixels) of the transmitted flux of neutrons were acquired at each imposed matric potential (~10-15 matric potential values per experiment) at the NCNR BT-2 neutron imaging beam line. Volumetric water contents were calculated on a pixel by pixel basis using Beer-Lambert s law after taking into account beam hardening and geometric corrections. To remove scattering effects at high water contents the volumetric water contents were normalized (to give relative saturations) by dividing the drying and wetting sequences of images by the images obtained at saturation and satiation, respectively. The resulting pixel values were then averaged and combined with information on the imposed basal matric potentials to give average water retention curves. The average relative saturations obtained by neutron radiography showed an approximate one-to-one relationship with the average values measured volumetrically using the hanging water column setup. There were no significant differences (at p < 0.05) between the parameters of the van Genuchten equation fitted to the average neutron radiography data and those estimated from replicated hanging water column data. Our results indicate that neutron imaging is a very effective tool for quantifying the average water retention curve.

  7. Neutron radiography of aircraft composite flight control surfaces

    International Nuclear Information System (INIS)

    Lewis, W.J.; Bennett, L.G.I.; Chalovich, T.R.; Francescone, O.

    2001-01-01

    A small (20 kWth), safe, pool-type nuclear research reactor called the SLOWPOKE-2 is located at the Royal Military College of Canada (RMC). The reactor was originally installed for teaching, training, research and semi-routine analysis, specifically, neutron activation analysis. It was envisioned that the neutrons from the SLOWPOKE-2 could also be used for neutron radiography, and so a research program was initiated to develop this technology. Over a period of approximately 15 years, and through a series of successive modifications, a neutron radiography system (NRS) was developed. Once completed, several applications of the technology have been demonstrated, including the nondestructive examination of the composite flight control surfaces from the Canadian Air Force's primary jet fighter, the CF18 Hornet aircraft. An initial trial was setup to investigate the flight control surfaces of 3 aircraft, to determine the parameters for a final licensed system, and to compare the results to other nondestructive methods. Over 500 neutron radiographs were made for these first 3 aircraft, and moisture and corrosion were discovered in the honeycomb structure and hydration was found in the composite and adhesive layers. In comparison with other NDT methods, neutron radiography was the only method that could detect the small areas of corrosion and moisture entrapment. However, before examining an additional 7 aircraft, the recommended modifications to the NRS were undertaken. These modifications were necessary to accommodate the larger flight control surfaces safely by incorporating flexible conformable shielding. As well, to expedite inspections so that all flight control surfaces from one aircraft could be completed in less than two weeks, there was a need to decrease the exposure time by both faster film/conversion screen combinations and by incorporating the capability of near realtime, digital radioscopy. Finally, as there are no inspection specific image quality

  8. Simultaneous neutron radiography and infrared thermography measurement of boiling processes

    International Nuclear Information System (INIS)

    Murphy, J.H.; Glickstein, S.S.

    1997-01-01

    Boiling of water at 1 to 15 bar flowing upward within a narrow duct and a round test section was observed using both neutron radiography and infrared (IR) thermography. The IR readings of the test section outer wall temperatures show the effects of both fluid temperature and wall heat transfer coefficient variations, producing a difference between liquid and two phase regions. The IR images, in fact, appear very similar to the neutron images; both show clear indications of spatial and temporal variations in the internal fluid conditions during the boiling process

  9. The neutron radiography facility at Tehran Research Reactor (TRR)

    International Nuclear Information System (INIS)

    Ali Pazirandeh

    2009-01-01

    Full text: Non-destructive testing in many fields of industry including detection of explosives, at the airports, testing for micro-cracks on airplane wings and turbine blades cracks is badly needed. Thermal neutron beam is one of preferable method to detect the micro-cracks, reveals the internal structure of components and explosives. The purpose of this paper is to present the neutron radiography facility at Tehran Research Reactor (TRR), Science and Technology Research Institute, and in particular to emphasize the industrial applications in wood industry, automobile engine inspection, minerals composition identification, turbine blade cracks detection. (author)

  10. Radioactive wastes storage rock porosity study using neutron radiography

    International Nuclear Information System (INIS)

    Peterka, F.

    1995-01-01

    Neutron radiography and neutron transmission analysis application to porosity study was mainly dealing with the building industry, the art protection and the basic research. Cooperation with the building industry has produced the solution of number of problems. Cement hydratation, concrete material, red brick sample, roofing tiles protection and epoxy resin efficiency for sand stones sculpture protection, can be cited as example. Many valuable experiences (like samples thickness, penetrating substances, detection techniques for the different experiments) were achieved. These can be used in the rockies formation studies too. Resolution is the proposal to JAERI and PNC for the cooperation, which can even be on the international basis. (J.P.N.)

  11. Upgrading of neutron radiography/tomography facility at research reactor

    International Nuclear Information System (INIS)

    Abd El Bar, Waleed; Mongy, Tarek

    2014-01-01

    A state-of-the-art neutron tomography imaging system was set up at the neutron radiography beam tube at the Egypt Second Research Reactor (ETRR-2) and was successfully commissioned in 2013. This study presents a set of tomographic experiments that demonstrate a high quality tomographic image formation. A computer technique for data processing and 3D image reconstruction was used to see inside a copy module of an ancient clay article provided by the International Atomic Energy Agency (IAEA). The technique was also able to uncover tomographic imaging details of a mummified fish and provided a high resolution tomographic image of a defective fire valve. (orig.)

  12. Studies and applications of neutron radiography with film methods

    International Nuclear Information System (INIS)

    Ikeda, Yasushi

    1989-01-01

    Neutron radiography has been studied with film methods and applied to some industrial applications. The film methods include not only conventional silver-halide emulsion films, such as industrial, medical or soft X-ray ones, but also track-etch films and those for indirect methods. The characteristics of the film methods are analyzed and investigated with using various image converters, such as gadolinium metal foil and evaporation films, or some scintillation converters such as NE426. The sensitivities and MTFs for various sets of films and converters have been obtained, which gives a chart of the correlation between the appropriate exposure and resolving powers for them. From the chart, one can select some proper sets for the purpose and given conditions of neutron radiography facilities. The film methods have been applied to inspect very fine cracks in thick steel blocks and plates. It is also applied to observe nuclear fuel pellets or irradiated nuclear fuel pins. Furthermore, the film method has been used for neutron computed tomography. Very fine Eu-particles in TiO pellets, which diameters are nearly 300 micron, can be reconstructed by the neutron CT. The fine neutron CT will be useful for the inspection of Pu-particles in mixed oxide nuclear fuel pellets for future advance nuclear reactors. (author)

  13. Energy-resolved fast neutron resonance radiography at CSNS

    Science.gov (United States)

    Tan, Zhixin; Tang, Jingyu; Jing, Hantao; Fan, Ruirui; Li, Qiang; Ning, Changjun; Bao, Jie; Ruan, Xichao; Luan, Guangyuan; Feng, Changqin; Zhang, Xianpeng

    2018-05-01

    The white neutron beamline at the China Spallation Neutron Source will be used mainly for nuclear data measurements. It will be characterized by high flux and broad energy spectra. To exploit the beamline as a neutron imaging source, we propose a liquid scintillator fiber array for fast neutron resonance radiography. The fiber detector unit has a small exposed area, which will limit the event counts and separate the events in time, thus satisfying the requirements for single-event time-of-flight (SEToF) measurement. The current study addresses the physical design criteria for ToF measurement, including flux estimation and detector response. Future development and potential application of the technology are also discussed.

  14. State and prospects of industrial neutron radiography in Germany

    International Nuclear Information System (INIS)

    Heidt, H.; Stade, J.

    1988-01-01

    Although the first neutron radiographies in Germany were made nearly 50 years ago, by Kallmann and Kuhn, this nondestructive testing method has not yet been widely used in industry. The main reason is the lack of mobile, intensive and low-cost neutron sources. Another important aspect is the availability of real-time inspection systems equipped with neutron image amplifiers which will accelerate the test and permit to represent dynamic processes. New applications for mobile neutron sources may be expected in aircraft inspection, in testing fibre-reinforced plastics, in different types of ceramic materials, in the building sector, in corrosion protection as well as with various problems encountered with lubrication agents. (orig.) [de

  15. Spectroscopic neutron radiography for a cargo scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Rahon, Jill [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); Danagoulian, Areg, E-mail: aregjan@mit.edu [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); MacDonald, Thomas D. [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); Hartwig, Zachary S. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); Lanza, Richard C. [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States)

    2016-06-01

    Detection of cross-border smuggling of illicit materials and contraband is a challenge that requires rapid, low-dose, and efficient radiographic technology. The work we describe here is derived from a technique which uses monoenergetic gamma rays from low energy nuclear reactions, such as {sup 11}B(d,nγ){sup 12}C, to perform radiographic analysis of shipping containers. Transmission ratios of multiple monoenergetic gamma lines resulting from several gamma producing nuclear reactions can be employed to detect materials of high atomic number (Z), the details of which will be described in a separate paper. Inherent in this particular nuclear reaction is the production of fast neutrons which could enable neutron radiography and further characterization of the effective-Z of the cargo, especially within the range of lower Z. Previous research efforts focused on the use of total neutron counts in combination with X-ray radiography to characterize the hydrogenous content of the cargo. We present a technique of performing transmitted neutron spectral analysis to reconstruct the effective Z and potentially the density of the cargo. This is made possible by the large differences in the energy dependence of neutron scattering cross-sections between hydrogenous materials and those of higher Z. These dependencies result in harder transmission spectra for hydrogenous cargoes than those of non-hydrogenous cargoes. Such observed differences can then be used to classify the cargo based on its hydrogenous content. The studies presented in this paper demonstrate that such techniques are feasible and can provide a contribution to cargo security, especially when used in concert with gamma radiography.

  16. Search for adequate quality standards for neutron radiography of nuclear fuel

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1983-01-01

    Unlike in other fields of industrial radiography, where standard methods and procedures are used to control the quality of the radiographic image, no such standard exists for neutron radiography of nuclear fuel. To fill that gap it was felt that standardization work ought to be started in that field, too. Accordingly in 1979 an Euratom Neutron Radiography Working Group was constituted, which initiated standardization work in the field of neutron radiography of nuclear fuel. Finding adequate standards for image quality of neutron radiographs and checking the accuracy of dimension measurements from them were given first priority. (Auth.)

  17. Focusing mirrors for enhanced neutron radiography with thermal neutrons and application for irradiated nuclear fuel

    Science.gov (United States)

    Rai, Durgesh K.; Abir, Muhammad; Wu, Huarui; Khaykovich, Boris; Moncton, David E.

    2018-01-01

    Neutron radiography is a powerful method of probing the structure of materials based on attenuation of neutrons. This method is most suitable for materials containing heavy metals, which are not transparent to X-rays, for example irradiated nuclear fuel and other nuclear materials. Neutron radiography is one of the first non-distractive post-irradiated examination methods, which is applied to gain an overview of the integrity of irradiated nuclear fuel and other nuclear materials. However, very powerful gamma radiation emitted by the samples is damaging to the electronics of digital imaging detectors and has so far precluded the use of modern detectors. Here we describe a design of a neutron microscope based on focusing mirrors suitable for thermal neutrons. As in optical microscopes, the sample is separated from the detector, decreasing the effect of gamma radiation. In addition, the application of mirrors would result in a thirty-fold gain in flux and a resolution of better than 40 μm for a field-of-view of about 2.5 cm. Such a thermal neutron microscope can be useful for other applications of neutron radiography, where thermal neutrons are advantageous.

  18. Assessment of Nugget Size of Spot Weld using Neutron Radiography

    Directory of Open Access Journals (Sweden)

    Triyono

    2011-08-01

    Full Text Available Resistance spot welding (RSW has been widely used for many years in the fabrication of car body structures, mainly due to the cost and time considerations. The weld quality as well as the nugget size is an issue in various manufacturing and processes due to the strong link between the weld quality and safety. It has led to the development of various destructive and non-destructive tests for spot welding such as peel testing, ultrasonic inspections, digital shearography, and infrared thermography. However, such methods cannot show spot weld nugget visually and the results are very operator’s skill dependent. The present work proposes a method to visualize the nugget size of spot welds using neutron radiography. Water, oil and various concentrations of gadolinium oxide-alcohol mixture were evaluated as a contrast media to obtain the best quality of radiography. Results show that mixture of 5 g gadolinium oxide (Gd2O3 in 25 ml alcohol produces the best contrast. It provides the possibility to visualize the shape and size of the nugget spot weld. Furthermore, it can discriminate between nugget and corona bond. The result of neutron radiography evaluation shows reasonable agreement with that of destructive test.

  19. Medical use of fast neutrons in radiotherapy and radiography

    International Nuclear Information System (INIS)

    Bewley, D.K.

    1975-01-01

    Over 400 patients have been treated with fast neutrons from a cyclotron at Hammersmith Hospital, London, using 16 MeV deuterons on beryllium. A large variety of malignant disease is included in this trial. A randomized trial of fast neutron therapy for cancer of the mouth and throat is in progress and preliminary results will be given. Fast neutron radiographs are often taken to check the positions of the fields used on the patients. These show no contrast from bone, but demonstrate only the presence of gas-filled cavities. As a diagnostic method, fast neutron radiography suffers from a number of disadvantages, the main ones being lack of sensitivity of the image-forming system and the hazard to the patient due to a large Quality Factor. Estimation of the absorbed dose given to different types of tissue is an important factor in the medical use of fast neutrons. More data are needed on the processes whereby fast neutrons impart energy to matter, particularly for neutrons above 15 MeV

  20. PEM Water Electrolysis: Preliminary Investigations Using Neutron Radiography

    Science.gov (United States)

    de Beer, Frikkie; van der Merwe, Jan-Hendrik; Bessarabov, Dmitri

    The quasi-dynamic water distribution and performance of a proton exchange membrane (PEM) electrolyzer at both a small fuel cell's anode and cathode was observed and quantitatively measured in the in-plane imaging geometry direction(neutron beam parallel to membrane and with channels parallel to the beam) by applying the neutron radiography principle at the neutron imaging facility (NIF) of NIST, Gaithersburg, USA. The test section had 6 parallel channels with an active area of 5 cm2 and in-situ neutron radiography observation entails the liquid water content along the total length of each of the channels. The acquisition was made with a neutron cMOS-camera system with performance of 10 sec per frame to achieve a relatively good pixel dynamic range and at a pixel resolution of 10 x 10 μm2. A relatively high S/N ratio was achieved in the radiographs to observe in quasi real time the water management as well as quantification of water / gas within the channels. The water management has been observed at increased steps (0.2A/cm2) of current densities until 2V potential has been achieved. These observations were made at 2 different water flow rates, at 3 temperatures for each flow rate and repeated for both the vertical and horizontal electrolyzer orientation geometries. It is observed that there is water crossover from the anode through the membrane to the cathode. A first order quantification (neutron scattering correction not included) shows that the physical vertical and horizontal orientation of the fuel cell as well as the temperature of the system up to 80 °C has no significant influence on the percentage water (∼18%) that crossed over into the cathode. Additionally, a higher water content was observed in the Gas Diffusion Layer at the position of the channels with respect to the lands.

  1. Characterization of non-tuberculosis mycobacteria by neutron radiography

    International Nuclear Information System (INIS)

    Silva, Jaqueline M. da; Crispim, Verginia Reis; Gomes da Silva, Marlei; Furtado, Vanessa Rodrigues; Duarte, Rafael Da Silva

    2013-01-01

    The genus Mycobacterium shares many characteristics with Corynebacterium and Actinomyces genera, among which the genomic guanine plus cytosine content and the production of long branched-chain fatty acids, known as mycolic acids are enhanced. Growth rate and optimal temperature of mycobacteria are variable. The genus comprises more than 140 known species; however Mycobacterium fortuitum, a fast growing nontuberculous mycobacterium, is clinically significant, because it has been associated to several lesions following surgery procedures such as liposuction, silicone breast and pacemaker implants, exposure to prosthetic materials besides sporadic lesions in the skin, soft tissues and rarely lungs. The objective of the present study is to reduce the time necessary for M. fortuitum characterization based on its morphology and the use of the neutron radiography technique substituting the classical biochemical assays. We also aim to confirm the utility of dendrimers as boron carriers. The samples were sterilized through conventional protocols using 10% formaldehyde. In the incubation process, two solutions with different molar ratios (10:1 and 20:1) of sodium borate and PAMAM G4 dendrimer and also pure sodium borate were used. After doping and sterilization procedures, the samples were deposited on CR-39 sheets, irradiated with a 4.6×10 5 n/cm 2 s thermal neutron flux for 30 min, from the J-9 irradiation channel of the Argonauta IEN/CNEN reactor. The images registered in the CR-39 were visualized in a Nikon E400 optical transmission microscope and captured by a Nikon Coolpix 995 digital camera. Developing the nuclear tracks registered in the CR-39 allowed a 1000× enlargement of mycobacterium images, facilitating their characterization, the use of more sophisticated equipment not being necessary. The use of neutron radiography technique reduced the time necessary for characterization. Doping with PAMAM dendrimer improved the visualization of NTM in neutron radiography

  2. Neutron radiography applications in I.T.U. TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, A. B.

    2002-01-01

    Neutron radiography is an important radiographic technique which is supplied different and advanced information according to the X or gamma ray radiography. However, it has a trouble for supplying the convenient neutron sources. Tangential beam tube of Istanbul Technical University (ITU) TRIGA Mark-II Training and Research Reactor has been arranged for using neutron radiography. The neutron radiography set defined as detailed for the application of the technique. Two different techniques for neutron radiography are defined as namely, transfer method and direct method. For the transfer method dysprosium and indium screens are used in the study. But, dysprosium generally was preferred in many studies in the point of view nuclear safety. Gadolinium was used for direct method. Two techniques are compared and explained the preferring of the transfer technique. Firstly, reference composition is prepared for seeing the differences between neutron and X-ray or gamma radiography. In addition of it, some radiograph samples are given neutron and X-ray radiography which shows the different image characters. Lastly, some examples are given from archaeometric studies. One of them the brass plates of Great Mosque door in Cizre. After the neutron radiography application, organic dye traces are noticed. Other study is on a sword that belong to Urartu period at the first millennium B.C. It is seen that some wooden part on it. Some different artefacts are examined with neutron radiography from the Ikiztepe excavation site, then some animal post parts are recognized on them. One of them is sword and sheath which are corroded together. After the neutron radiography application, it can be noticed that there are a cloth between the sword and its sheath. By using neutron radiography, many interesting and detailed results are observed in ITU TRIGA Mark-II Training and Research Reactor. Some of them shouldn't be recognised by using any other technique

  3. Research on neutron radiography in Research Reactor Institute, Kyoto University and activities related to it

    International Nuclear Information System (INIS)

    Fujine, Shigenori; Yoneda, Kenji

    1994-01-01

    The research on neutron radiography in Research Reactor Institute, Kyoto University was begun in 1974 using the E-2 experimental hole which was designed for neutron irradiation. It was reconstructed for the excellent performance as neutron radiography facility by fixing aluminum plugs, a collimator and so on. The research activities thereafter are briefly described. In 1989, the cold neutron facility was installed in the graphite thermal neutron facility, and the experiment on cold neutron radiography became feasible. The reactor in Kyoto University is of the thermal output of 5 MW, and is put to the joint utilization by universities and research institutes in whole Japan. The experimental items carried out so far are enumerated. At present, the main subjects of research are the development of the standard for establishing image evaluation method, the analysis of gas-liquid two-phase flow, the construction of the data base for the literatures and images of neutron radiography, the application of cold neutron radiography, the development of the imaging method using fast neutrons and so on. The thermal neutron radiography and the cold neutron radiography facilities of Kyoto University research reactor are described. The research and activities at Kyoto University research reactor and the investigation of problems are reported. (K.I.) 56 refs

  4. An empirical formula for scattered neutron components in fast neutron radiography

    International Nuclear Information System (INIS)

    Dou Haifeng; Tang Bin

    2011-01-01

    Scattering neutrons are one of the key factors that may affect the images of fast neutron radiography. In this paper, a mathematical model for scattered neutrons is developed on a cylinder sample, and an empirical formula for scattered neutrons is obtained. According to the results given by Monte Carlo methods, the parameters in the empirical formula are obtained with curve fitting, which confirms the logicality of the empirical formula. The curve-fitted parameters of common materials such as 6 LiD are given. (authors)

  5. Study of the RP-10 reactor neutron beam applied to the neutron radiography

    International Nuclear Information System (INIS)

    Zegarra, Manuel; Lopez, Alcides

    2013-01-01

    We have studied the RP-10 reactor radial neutron beam No. 3, which is used for neutron radiographies, by comparing radiograph's with and without the inner duct, and neutron flux determination with in flakes along the external duct, being the presence of photons creating signals at comparable levels of neutron effects, which reduce the quality of the analysis, values around 10 6 and 10 4 n/cm 2 s for thermal and epithermal flux were obtained respectively. It is recommended evaluate the design of the internal duct which presents strong photon emission. (authors).

  6. Calibration of quantitative neutron radiography method for moisture measurement

    International Nuclear Information System (INIS)

    Nemec, T.; Jeraj, R.

    1999-01-01

    Quantitative measurements of moisture and hydrogenous matter in building materials by neutron radiography (NR) are regularly performed at TRIGA Mark II research of 'Jozef Stefan' Institute in Ljubljana. Calibration of quantitative method is performed using standard brick samples with known moisture content and also with a secondary standard, plexiglas step wedge. In general, the contribution of scattered neutrons to the neutron image is not determined explicitly what introduces an error to the measured signal. Influence of scattered neutrons is significant in regions with high gradients of moisture concentrations, where the build up of scattered neutrons causes distortion of the moisture concentration profile. In this paper detailed analysis of validity of our calibration method for different geometrical parameters is presented. The error in the measured hydrogen concentration is evaluated by an experiment and compared with results obtained by Monte Carlo calculation with computer code MCNP 4B. Optimal conditions are determined for quantitative moisture measurements in order to minimize the error due to scattered neutrons. The method is tested on concrete samples with high moisture content.(author)

  7. Morphological change of plant root revealed by neutron radiography

    International Nuclear Information System (INIS)

    Makino-Nakanishi, Tomoko; Matsumoto, Satoshi; Kobayashi, Hisao.

    1992-01-01

    Morphological change with soybean root development was investigated non-destructively by neutron radiography. Not only the main root but also the side roots were shown as an clear image on both X-ray and dry films. In the case of dry film, the resolution of the image obtained was about the same as that by X-ray film and the thermal neutron flux was reduced to be about one fifteenth. The image of the root was much clearly obtained in the sand than in the soil where the soil aggregates were randomly shown. In order to know to which degree the root can be shown in the image, the aluminum containers with various thickness were tested. Even when the thickness of the container was increased up to 1.7 cm, the image of the main root was clearly observed through the soil. It was shown that by neutron radiography the morphology of the plant root could be traced non-destructively during the development of the plant. (author)

  8. Development of neutron detectors and neutron radiography at ...

    Indian Academy of Sciences (India)

    BARC, Department of Atomic Energy units and some universities and research institutes in India and .... by Solid State Physics Division for various applications, using the 400 kW swim- ming pool type reactor, Apsara as the neutron source.

  9. The drying process of concrete: a neutron radiography study

    International Nuclear Information System (INIS)

    Beer, F.C. de; Strydom, W.J.; Griesel, E.J.

    2004-01-01

    The natural drying process of concrete, which has a significant effect on its characteristics, for example durability, was studied at the neutron radiography facility at SAFARI-1 nuclear research reactor, operated by Necsa. Monitoring of the movement of the water in concrete samples, which were wet cured for one day and covered on all the sides but one, was done by means of a CCD camera system. In this paper the methodology in observing the drying process will be described together with results obtained from this investigation. The measured water content and porosity results were quantified and compared reasonably well with conventional gravimetrical measurements

  10. Application of neutron radiography to visualization of multiphase flows

    International Nuclear Information System (INIS)

    Takenaka, N.; Fujii, T.; Nishizaki, K.; Asano, H.; Ono, A.; Sonoda, K.; Akagawa, K.

    1990-01-01

    Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author)

  11. Neutron radiography at the University of Michigan's Phoenix Memorial Laboratory

    International Nuclear Information System (INIS)

    Lindsay, J.T.; Elam, S.; Koblish, T.; Lee, P.; McAuliffe, D.

    1990-01-01

    Real-time neutron radiography (RTNR) is rapidly becoming a valuable tool for nondestructive testing and basic research with a wide variety of applications. The Phoenix Memorial Laboratory (PML) at the University of Michigan has developed an RTNR facility and has been using this facility to study several phenomena of interest to researchers in many areas. These phenomena include imaging of the internal fluid flow in gas turbine engine nozzles and coking and debris deposition in several gas turbine nozzles. This paper presents a summary of the technique and facilities involved in these applications

  12. Radiation dose distribution monitoring at neutron radiography facility area, Nuclear Energy Unit, Malaysia

    International Nuclear Information System (INIS)

    Abdul Razak Daud

    1995-01-01

    One experiment was carried out to get the distribution of radiation doses at the neutron radiography facilities, Nuclear Energy Unit, Malaysia. The analysis was done to evaluate the safety level of the area. The analysis was used in neutron radiography work

  13. Shielding calculations for the design of neutron radiography facility around PARR

    International Nuclear Information System (INIS)

    Ashraf, M.M.; Khan, A.R.

    1989-06-01

    Shielding calculations for neutron radiography facility, proposed to be established around PARR have been carried out using two group diffusion theory and shielding formulae. Gamma radiation penetration calculations have been carried out using simple attenuation methods. The fabrication and installation of the neutron radiography facility would provide the basis for designing a better collimating system and would help establish under water radiography facility for the inspection of highly radioactive materials and components etc. (orig./A.B.)

  14. The quality assessment of radial and tangential neutron radiography beamlines of TRR

    International Nuclear Information System (INIS)

    Dastjerdi, M.H. Choopan; Movafeghi, A.; Khalafi, H.; Kasesaz, Y.

    2017-01-01

    To achieve a quality neutron radiographic image in a relatively short exposure time, the neutron radiography beam must be of good quality and relatively high neutron flux. Characterization of a neutron radiography beam, such as determination of the image quality and the neutron flux, is vital for producing quality radiographic images and also provides a means to compare the quality of different neutron radiography facilities. This paper provides a characterization of the radial and tangential neutron radiography beamlines at the Tehran research reactor. This work includes determination of the facilities category according to the American Society for Testing and Materials (ASTM) standards, and also uses the gold foils to determine the neutron beam flux. The radial neutron beam is a Category I neutron radiography facility, the highest possible quality level according to the ASTM. The tangential beam is a Category IV neutron radiography facility. Gold foil activation experiments show that the measured neutron flux for radial beamline with length-to-diameter ratio (L/D) =150 is 6.1× 10 6 n cm −2 s −1 and for tangential beamline with (L/D)=115 is 2.4× 10 4 n cm −2 s −1 .

  15. Flow visualization through metal enclosures with neutron radiography

    International Nuclear Information System (INIS)

    Cimbala, J.M.; Sathianathan, D.; Cosgrove, S.A.

    1989-01-01

    Many practical fluid flow problems involve flow inside metal shrouds (valves, combustors, boilers, turbomachinery, etc.) where visual access is not available. For flows under extreme pressure or heat, glass or transparent plastic can not be used; a flow visualization technique which permits visualization through metal containers is needed in these cases. Since neutrons can penetrate metal casings, neutron radiography has been developed for application to fluid flow visualization. This technique involves imaging of neutron opaque tracer materials, such as solid or fluid particles or streaklines, as they convect in neutron transparent ambient fluids. Surface flow visualization is also possible by using neutron opaque tufts. An extension of the surface tuft technique has also been developed, enabling the visualization of flow a patterns away from solid surfaces. This paper presents a summary of the various flow visualization techniques developed in the authors' laboratory, along with examples which illustrate how these techniques may be applied to practical fluid flow problems. These include flow over a circular cylinder, the recirculation pattern formed by a jet exhausting into a tank, and the flow pattern inside a rotating automotive torque converter

  16. Boron determination in tourmaline by neutron induced radiography

    Energy Technology Data Exchange (ETDEWEB)

    Qureshi, A.A. E-mail: aaqureshi@pinstech.org.pk; Akram, M.; Ayub Khan, M.; Khattak, N.U.; Qureshi, I.E.; Khan, H.A

    2001-06-01

    The technique of neutron induced radiography has been applied to determine the boron concentration and its spatial distribution in mineral tourmaline collected from Swat Tourmaline Granite, Northern Pakistan. The technique involves the simultaneous irradiation of sample and a standard fixed on a track detector with thermal neutrons and the counting of alpha and {sup 7}Li tracks produced in the detector from the nuclear reaction {sup 10}B(n,{alpha}){sup 7}Li. Boron concentration is determined by comparing the {sup 7}Li and alpha particle tracks density with that of a standard of known boron concentration. Boron concentration in tourmaline has been found to be (3.40{+-}0.01)% in this study which is on the upper side within the normal range (2.5-3.8)% reported in the world. The presence of somewhat higher concentration of boron in tourmaline indicates that the Swat Tourmaline Granite was generated as a late stage hydrothermal activity during the Himalayan Orogeny.

  17. Non-destructive studies of fuel pellets by neutron resonance absorption radiography and thermal neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, A.S., E-mail: ast@ssl.berkeley.edu [University of California, Berkeley, CA 94720 (United States); Vogel, S.C.; Mocko, M.; Bourke, M.A.M.; Yuan, V.; Nelson, R.O.; Brown, D.W. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Feller, W.B. [NOVA Scientific, Inc., 10 Picker Rd., Sturbridge, MA 01566 (United States)

    2013-09-15

    Many isotopes in nuclear materials exhibit strong peaks in neutron absorption cross sections in the epithermal energy range (1–1000 eV). These peaks (often referred to as resonances) occur at energies specific to particular isotopes, providing a means of isotope identification and concentration measurements. The high penetration of epithermal neutrons through most materials is very useful for studies where samples consist of heavy-Z elements opaque to X-rays and sometimes to thermal neutrons as well. The characterization of nuclear fuel elements in their cladding can benefit from the development of high resolution neutron resonance absorption imaging (NRAI), enabled by recently developed spatially-resolved neutron time-of-flight detectors. In this technique the neutron transmission of the sample is measured as a function of spatial location and of neutron energy. In the region of the spectra that borders the resonance energy for a particular isotope, the reduction in transmission can be used to acquire an image revealing the 2-dimensional distribution of that isotope within the sample. Provided that the energy of each transmitted neutron is measured by the neutron detector used and the irradiated sample possesses neutron absorption resonances, then isotope-specific location maps can be acquired simultaneously for several isotopes. This can be done even in the case where samples are opaque or have very similar transmission for thermal neutrons and X-rays or where only low concentrations of particular isotopes are present (<0.1 atom% in some cases). Ultimately, such radiographs of isotope location can be utilized to measure isotope concentration, and can even be combined to produce three-dimensional distributions using tomographic methods. In this paper we present the proof-of-principle of NRAI and transmission Bragg edge imaging performed at Flight Path 5 (FP5) at the LANSCE pulsed, moderated neutron source of Los Alamos National Laboratory. A set of urania mockup

  18. Visualization of thermal management system in space using neutron radiography

    International Nuclear Information System (INIS)

    Nakazawa, Takeshi

    1995-01-01

    The visualizing technique by neutron radiography is effective for visualizing liquid in metals, and the applications in wide fields have been reported. In this paper, as one of the examples of applying the visualizing technique by neutron radiography, the experiment of visualizing the two-phase fluid loop heat removal system for the purpose of using in spatial environment was carried out, and its results are reported. For future large scale space ships and space stations, the heat removal system with two-phase fluid loop which utilizes the phase transformation of heat transport media is regarded as promising. By this system, good heat transfer performance is obtained, transported heat quantity per unit mass of media increases, and pumping power and the weight of the total system are reduced. Temperature can be controlled by system pressure. The two-phase fluid loop for the visualization experiment and the experimental results are reported. By the experiment using the real time NRG system at the JRR-3M, the boiling and evaporation phenomena in the capillary heat transfer tubes were able to be visualized. (K.I.)

  19. Visualization and measurement of fluid phenomena using neutron radiography techniques

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Hibiki, Takashi; Fujine, Shigenori; Yoneda, Kenji; Kanda, Keiji; Nishihara, Hideaki; Tsuruno, Akira; Matsubayashi, Masahito; Sobajima, Makoto; Ohtomo, Shoichi.

    1993-01-01

    This paper presents some of the results from recent work performed on the application of neutron radiography to visualization and measurement of fluid phenomena at the Research Reactor Institute of Kyoto University. Experiments have been performed on the following subjects with use of the NR systems at the Japan Research Reactor 3 and the Nuclear Safety Research Reactor of the Japan Atomic Energy Research Institute as well as the Kyoto University Research Reactor: air-water flow in rectangular ducts with 1.0 and 2.4 mm gaps, air-water flow and steam-water flow in a round tube with 4.0 mm inner diameter. The void fraction was measured by processing the images taken by the neutron radiography. The effect of several corrections in image processing was also discussed previously. It was shown that the proposed method could be useful in observing the flow regimes and measuring the void fraction of gas-liquid two-phase flow in narrow channels. (author)

  20. Neutron Flux Distribution on Neutron Radiography Facility After Fixing the Collimator

    International Nuclear Information System (INIS)

    Supandi; Parikin; Mohtar; Sunardi; Roestam, S

    1996-01-01

    The Radiography Neutron Facility consists of an inner collimator, outer collimator, main shutter, second shutter and the sample chamber with 300 mm in diameter. Neutron beam quality depends on the neutron flux intensities distribution, L/D ratio Cd ratio, neutron/gamma ratio. The results show that the neutron flux intensity was 2.83 x 107 n cm-2.s-1, with deviation of + 7.8 % and it was distributed homogeneously at the sample position of 200 mm diameter. The beam characteristics were L/D ratio 98 and Rod 8, and neutron gamma ratio 3.08 x 105n.cm-2.mR-1 and Reactor Power was 20 MW. This technique can be used to examine sample with diameter of < 200 mm

  1. Neutron Focusing Mirrors for Neutron Radiography of Irradiated Nuclear Fuel at Idaho National Laboratory

    Science.gov (United States)

    Rai, Durgesh K.; Wu, Huarui; Abir, Muhammad; Giglio, Jeffrey; Khaykovich, Boris

    Post irradiation examination (PIE) of samples irradiated in nuclear reactors is a challenging but necessary task for the development on novel nuclear power reactors. Idaho National Laboratory (INL) has neutron radiography capabilities, which are especially useful for the PIE of irradiated nuclear fuel. These capabilities are limited due to the extremely high gamma-ray radiation from the irradiated fuel, which precludes the use of standard digital detectors, in turn limiting the ability to do tomography and driving the cost of the measurements. In addition, the small 250 kW Neutron Radiography Reactor (NRAD) provides a relatively weak neutron flux, which leads to low signal-to-noise ratio. In this work, we develop neutron focusing optics suitable for the installation at NRAD. The optics would separate the sample and the detector, potentially allowing for the use of digital radiography detectors, and would provide significant intensity enhancement as well. The optics consist of several coaxial nested Wolter mirrors and is suited for polychromatic thermal neutron radiation. Laboratory Directed Research and Development program of Idaho National Laboratory.

  2. New generation non-stationary portable neutron generators for biophysical applications of Neutron Activation Analysis.

    Science.gov (United States)

    Marchese, N; Cannuli, A; Caccamo, M T; Pace, C

    2017-01-01

    Neutron sources are increasingly employed in a wide range of research fields. For some specific purposes an alternative to existing large-scale neutron scattering facilities, can be offered by the new generation of portable neutron devices. This review reports an overview for such recently available neutron generators mainly addressed to biophysics applications with specific reference to portable non-stationary neutron generators applied in Neutron Activation Analysis (NAA). The review reports a description of a typical portable neutron generator set-up addressed to biophysics applications. New generation portable neutron devices, for some specific applications, can constitute an alternative to existing large-scale neutron scattering facilities. Deuterium-Deuterium pulsed neutron sources able to generate 2.5MeV neutrons, with a neutron yield of 1.0×10 6 n/s, a pulse rate of 250Hz to 20kHz and a duty factor varying from 5% to 100%, when combined with solid-state photon detectors, show that this kind of compact devices allow rapid and user-friendly elemental analysis. "This article is part of a Special Issue entitled "Science for Life" Guest Editor: Dr. Austen Angell, Dr. Salvatore Magazù and Dr. Federica Migliardo". Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Thermal neutron filter design for the neutron radiography facility at the LVR-15 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Soltes, Jaroslav [Research Centre Rez Ltd., Husinec - Rez 130, 250 68 Rez, (Czech Republic); Faculty of Nuclear Sciences and Physical Engineering, CTU in Prague, (Czech Republic); Viererbl, Ladislav; Lahodova, Zdena; Koleska, Michal; Vins, Miroslav [Research Centre Rez Ltd., Husinec - Rez 130, 250 68 Rez, (Czech Republic)

    2015-07-01

    In 2011 a decision was made to build a neutron radiography facility at one of the unused horizontal channels of the LVR-15 research reactor in Rez, Czech Republic. One of the key conditions for operating an effective radiography facility is the delivery of a high intensity, homogeneous and collimated thermal neutron beam at the sample location. Additionally the intensity of fast neutrons has to be kept as low as possible as the fast neutrons may damage the detectors used for neutron imaging. As the spectrum in the empty horizontal channel roughly copies the spectrum in the reactor core, which has a high ratio of fast neutrons, neutron filter components have to be installed inside the channel in order to achieve desired beam parameters. As the channel design does not allow the instalment of complex filters and collimators, an optimal solution represent neutron filters made of large single-crystal ingots of proper material composition. Single-crystal silicon was chosen as a favorable filter material for its wide availability in sufficient dimensions. Besides its ability to reasonably lower the ratio of fast neutrons while still keeping high intensities of thermal neutrons, due to its large dimensions, it suits as a shielding against gamma radiation from the reactor core. For designing the necessary filter dimensions the Monte-Carlo MCNP transport code was used. As the code does not provide neutron cross-section libraries for thermal neutron transport through single-crystalline silicon, these had to be created by approximating the theory of thermal neutron scattering and modifying the original cross-section data which are provided with the code. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the expected calculated values

  4. Fast neutron (14.5 MeV) radiography: a comparative study

    International Nuclear Information System (INIS)

    Klann, R.T.

    1996-01-01

    Fast neutron (14.5 MeV) radiography is a type of non-destructive analysis tool that offers its own benefits and drawbacks. Because cross-sections vary with energy, a different range of materials can be examined with fast neutrons than can be studied with thermal neutrons, epithermal neutrons, or x-rays. This paper details these differences through a comparative study of fast neutron radiography to the other types of radiography available. The most obvious difference among the different types of radiography is in the penetrability of the sources. Fast neutrons can probe much deeper and can therefore obtain details of the internals of thick objects. Good images have been obtained through as much as 15 cm of steel, 10 cm of water, and 15 cm of borated polyethylene. In addition, some objects were identifiable through as much as 25 cm of water or 30 cm of borated polyethylene. The most notable benefit of fast neutron radiography is in the types of materials that can be tested. Fast neutron radiography can view through materials that simply cannot be viewed by X rays, thermal neutrons, or epithermal neutrons due to the high cross-sections or linear attenuation coefficients involved. Cadmium was totally transparent to the fast neutron source. Fast neutron radiography is not without drawbacks. The most pronounced drawback has been in the quality of radiograph produced. The image resolution is only about 0.8 mm for a 1.25 cm thick object, whereas, other forms of radiography have much better resolution

  5. Detection of plastic explosives using thermal neutron radiography

    International Nuclear Information System (INIS)

    Hacidume, Leo Ryoske

    1999-12-01

    The work aims to demonstrate the potentiality of the neutron radiography technique, allied to the computerized tomography by transmission, to both detect and visualize plastic explosive samples in several hidden conditions, using a simple scanner as a digitalisation instrument. Each tomographic essay was obtained in the J-9 channel of the Argonauta Research Reactor of IEN/CNEN, in groups of six neutron radiographic projections, performed with an angular increment of 30 deg C, in a period of time of 30 minutes for each projection. Two groups of tomographic reconstructions were generated, distinguished by the digitalisation process of the interested lines in the reconstruction plane coming from the projection groups, utilization a scanner and a microdensitometer, respectively. The reconstruction of the bi-dimensional image of the transverse section, in relation to this plane, was processed making use of the Image Reconstruction Algorithmic of an Image based on the Maximum Entropy principle (ARIEM). From the qualitative analysis of the images, we conclude that the neutron radiographic system was able to detect the explosive sample in a satisfactory way while the quantitative analysis confirmed the application effectiveness of a scanner to acquire the projection dates whose objective is only a reconnaissance. (author)

  6. Detection of plastic explosives by thermic neutron radiography

    International Nuclear Information System (INIS)

    Hacidume, Leo R.; Crispim, Verginia R.; Silva, Ademir X. da

    2000-01-01

    This work aims to demonstrate the potentiality of the neutron radiography technique, allied to the computerized tomography by transmission, to both detect and visualize plastic explosive samples in several hidden conditions, using a simple scanner as a digitalisation instrument. Each tomographic essay was obtained in the J-9 channel of the Argonauta Research Reactor of IEN/CNEN, in groups of six neutron radiographic projections, performed with an angular increment of 30 in a period of time of 30 minutes for each projection. Two groups of tomographic reconstructions were generated, distinguished by the digitalisation process of the interested lines in the reconstruction plane coming from the projection groups, utilizing a scanner and a microdensitometer, respectively. The reconstruction of the bi-dimensional image of the transverse section, in relation to this plane, was processed making use of the Image reconstruction algorithmic of an image based on the maximum entropy principle (ARIEM). From the qualitative analysis of the images, we conclude that the neutron radiographic system was able to detect the explosive sample in a satisfactory way while the quantitative analysis confirmed the application effectiveness of a scanner to acquire the projection dates whose objective is only a reconnaissance. (author)

  7. Visualization and measurement by image processing of thermal hydraulic phenomena by neutron radiography

    International Nuclear Information System (INIS)

    Takenaka, Nobuyuki

    1996-01-01

    Neutron Radiography was applied to visualization of thermal hydraulic phenomena and measurement was carried out by image processing the visualized images. Since attenuation of thermal neutron rays is high in ordinary liquids like water and organic fluid while it is low in most of metals, liquid flow behaviors can be visualized through a metallic wall by neutron radiography. Measurement of void fraction and flow vector field which is important to study thermal hydraulic phenomena can be carried out by image processing the images obtained by the visualization. Various two-phase and liquid metal flows were visualized by a JRR-3M thermal neutron radiography system in the present study. Multi-dimensional void fraction distributions in two-phase flows and flow vector fields in liquid metals, which are difficult to measure by the other methods, were successfully measured by image processing. It was shown that neutron radiography was efficiently applicable to study thermal hydraulic phenomena. (author)

  8. Neutron radiography examination of objects belonging to the cultural heritage

    International Nuclear Information System (INIS)

    Rant, Joze; Milic, Zoran; Istenic, Janka; Knific, Timotej; Lengar, Igor; Rant, Andrej

    2006-01-01

    Examination of the internal structure and composition of cultural object is extremely important for its conservation and should be carried out before conservation is planned. Knowledge of the internal structure of an object is also important for the study of ancient manufacturing technologies and sometimes also for determination of its function. In the examination of the interior structure and composition of cultural objects often only methods involving non-destructive examination (NDE) are acceptable. The shape, structure and condition of metal parts can be revealed, e.g. by conventional X-ray Radiography (XR), or computed tomography (CT), while Neutron Radiography (NR) primarily helps to detect the presence of organic materials and in their identification. In the paper some typical examples of the use of NR in the examination of the internal structure of selected cultural objects are presented. The examination of these objects by NDE techniques was an integral part of their conservation process, as well as of their study by archaeologists and historians

  9. Inspection of an artificial heart by the neutron radiography technique

    International Nuclear Information System (INIS)

    Pugliesi, R.; Geraldo, L.P.; Andrade, M.L.G.; Menezes, M.O.; Pereira, M.A.S.; Maizato, M.J.S.

    1999-01-01

    The neutron radiography technique was employed to inspect an artificial heart prototype which is being developed to provide blood circulation for patients expecting heart transplant surgery. The radiographs have been obtained by the direct method with a gadolinium converter screen along with the double coated Kodak-AA emulsion film. The artificial heart consists of a flexible plastic membrane located inside a welded metallic cavity, which is employed for blood pumping purposes. The main objective of the present inspection was to identify possible damages in this plastic membrane, produced during the welding process of the metallic cavity. The obtained radiographs were digitized as well as analysed in a PC and the improved images clearly identify several damages in the plastic membrane, suggesting changes in the welding process

  10. Inspection of an artificial heart by the neutron radiography technique

    CERN Document Server

    Pugliesi, R; Andrade, M L G; Menezes, M O; Pereira, M A S; Maizato, M J S

    1999-01-01

    The neutron radiography technique was employed to inspect an artificial heart prototype which is being developed to provide blood circulation for patients expecting heart transplant surgery. The radiographs have been obtained by the direct method with a gadolinium converter screen along with the double coated Kodak-AA emulsion film. The artificial heart consists of a flexible plastic membrane located inside a welded metallic cavity, which is employed for blood pumping purposes. The main objective of the present inspection was to identify possible damages in this plastic membrane, produced during the welding process of the metallic cavity. The obtained radiographs were digitized as well as analysed in a PC and the improved images clearly identify several damages in the plastic membrane, suggesting changes in the welding process.

  11. Neutron resonance radiography: Report of a workshop, Los Alamos, NM: July 27-29, 1987

    International Nuclear Information System (INIS)

    1988-07-01

    Neutron resonance radiography is a new technique with great potential for non-destructive analysis and testing. This technique has been under research and development in a number of major research laboratories for some time. Unlike thermal neutron radiography, which is primarily oriented towards imaging hydrogen and a number of other highly neutron-absorptive materials without necessarily distinguishing between them, neutron resonance radiography has the capability of uniquely identifying many kinds of chemical elements and their individual isotopes. It also has the potential for temperature imaging in materials containing heavy elements and for certain dynamic features such as stroboscopic imaging. Although neutron resonance radiography has not yet been taken up in a systematic way for technological applications, significant development of ideas and instrumentation at the research level has blossomed. There have also been major developments in the availability of powerful pulsed-neutron sources. In light of these developments, the Los Alamos Neutron Scattering Center sponsored a workshop with the general aims of reviewing scientific and technical progress, discussing and highlighting future developments, and stimulating interest in technological exploitation of the methods. In addition to the techniques and instrumentation required for the field, the applications of neutron resonance radiography in some of the following industrial and manufacturing areas were discussed: nuclear fuel assay; nuclear safeguards in general; aerospace development (aeroengine blade temperature, stroboscopic techniques); diagnostics; non-nuclear industry (especially metallurgy); temperature imaging; use of mobile pulsed-neutron sources; and practical use of major pulsed-neutron facilities

  12. Recognition of internal structure of unknown objects with simultaneous neutron and gamma radiography

    International Nuclear Information System (INIS)

    Moghadam, K.K.; Nasseri, M.M.

    2004-01-01

    Generally speaking in customary industrial and medical radiography, there is no tendency to reveal the nature of the samples. Ordinarily, the main objective of taking a radiograph is to show the position and dimension of unknown parts, inside the test object and to determine cracks, defects, etc. Whereas in radiography many important factors such as material cross-sections and build-up factors are also involved. In this paper, by using both neutron and gamma radiography techniques, some mathematical relations were successfully generated, in order to calculate the neutron and gamma total macroscopic cross-sections of some unknown elements in the presence of the other elements. For this work, some test pieces were defined and made of lead, silver, copper, Nickel, tin, graphite and polyethylene. The neutron radiography facility at Tehran Research Reactor (TRR) was used as mixed neutron and gamma radiography source (Proceedings of the Second World Conference on Neutron Radiography, Paris, France, pp. 25-32). On testing of a correction of the above-mentioned generated relations, a new technique of simultaneous neutron and gamma radiography was also investigated

  13. Neutron emission in neutral beam heated KSTAR plasmas and its application to neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Jong-Gu, E-mail: jgkwak@nfri.re.kr; Kim, H.S.; Cheon, M.S.; Oh, S.T.; Lee, Y.S.; Terzolo, L.

    2016-11-01

    Highlights: • We measured the neutron emission from KSTAR plasmas quantitatively. • We confirmed that neutron emission is coming from neutral beam-plasma interactions. • The feasibility study shows that the fast neutron from KSTAR could be used for fast neutron radiography. - Abstract: The main mission of Korea Superconducting Tokamak Advanced Research (KSTAR) program is exploring the physics and technologies of high performance steady state Tokamak operation that are essential for ITER and fusion reactor. Since the successful first operation in 2008, the plasma performance is enhanced and duration of H-mode is extended to around 50 s which corresponds to a few times of current diffusion time and surpassing the current conventional Tokamak operation. In addition to long-pulse operation, the operational boundary of the H-mode discharge is further extended over MHD no-wall limit(β{sub N} ∼ 4) transiently and higher stored energy region is obtained by increased total heating power (∼6 MW) and plasma current (I{sub p} up to 1 MA for ∼10 s). Heating system consists of various mixtures (NB, ECH, LHCD, ICRF) but the major horse heating resource is the neutral beam(NB) of 100 keV with 4.5 MW and most of experiments are conducted with NB. So there is a lot of production of fast neutrons coming from via D(d,n){sup 3}He reaction and it is found that most of neutrons are coming from deuterium beam plasma interaction. Nominal neutron yield and the area of beam port is about 10{sup 13}–10{sup 14}/s and 1 m{sup 2} at the closest access position of the sample respectively and neutron emission could be modulated for application to the neutron radiography by varying NB power. This work reports on the results of quantitative analysis of neutron emission measurements and results are discussed in terms of beam-plasma interaction and plasma confinement. It also includes the feasibility study of neutron radiography using KSTAR.

  14. Radiation shielding material characterization by non-destructive neutron radiography technique

    International Nuclear Information System (INIS)

    Hafizal Yazid; Azali Muhammad; Abdul Aziz Mohamed; Rafhayudi Jamro; Hishamuddin Husain

    2007-01-01

    Shielding property of boronated rubber was characterized easily by the use of neutron radiography technique. For 10 phr of boron carbide in the natural rubber composite, the ability to completely shield against neutron was found to have 8mm thickness and above for the neutron flux of 1.04 x 10 5 n/cm 2 s (author)

  15. Neutron radiography and other NDE tests of main rotor helicopter blades

    CSIR Research Space (South Africa)

    De Beer, FC

    2004-10-01

    Full Text Available leading to aircraft structural failures, are addressed by various NDE techniques. In a combined investigation by means of visual inspection, X-ray radiography and shearography on helicopter main rotor blades, neutron radiography (NRad) at SAFARI-1 research...

  16. Measurements in support of a neutron radiography facility for the SLOWPOKE-2 at RMC

    International Nuclear Information System (INIS)

    Lewis, W.J.; Andrews, W.S.; Bennett, L.G.I.; Beeley, P.A.; Royal Military Coll. of Canada, Kingston, ON

    1990-01-01

    The feasibility of using the small (20 kWh) SLOWPOKE-2 research reactor for neutron radiography has been investigated. Although designed primarily for neutron activation analysis (NAA) and radioisotope production, the SLOWPOKE-2 at RMC was installed with a thermal column of heavy water in a sector of the water gap between the beryllium reflector and the reactor container. The thermal-neutron flux in the reactor pool, just beyond the reactor container, has been measured to be a factor of 2.7 higher than in similar locations remote from the thermal column. Placed in this location was a prototype neutron radiography facility, consisting of a beam tube (or collimator), vertically tangential to the reactor core, and a beam stop. Once the feasibility of using a SLOWPOKE-2 for neutron radiography was demonstrated, subsequent investigations were carried out to optimize the quality of the obtainable radiographs. Both neutron radiographic and thermal-neutron flux measurements were undertaken to determine the optimum placement and arrangement of the beam tube. A Category III (as defined by the ASTM Standard E545-86) neutron radiography facility was obtained, although Category I or II were indicated as feasible. Based on this prototype design and experimentation, a permanent neutron radiography facility will be installed. The design calculations have been finalized, construction blueprints have been prepared, and work is proceeding with the construction, installation and commissioning of the facility. (orig.)

  17. Neutron-induced alpha radiography; Radiografia com particulas alfa induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Marco Antonio Stanojev

    2008-07-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the {alpha} - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 {mu}m in thickness can be inspected with a spatial resolution of 32 {mu}m. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to {beta}, {gamma}, X-ray and visible light. (author)

  18. Characterization of a Neutron Beam Following Reconfiguration of the Neutron Radiography Reactor (NRAD Core and Addition of New Fuel Elements

    Directory of Open Access Journals (Sweden)

    Aaron E. Craft

    2016-02-01

    Full Text Available The neutron radiography reactor (NRAD is a 250 kW Mark-II Training, Research, Isotopes, General Atomics (TRIGA reactor at Idaho National Laboratory, Idaho Falls, ID, USA. The East Radiography Station (ERS is one of two neutron beams at the NRAD used for neutron radiography, which sits beneath a large hot cell and is primarily used for neutron radiography of highly radioactive objects. Additional fuel elements were added to the NRAD core in 2013 to increase the excess reactivity of the reactor, and may have changed some characteristics of the neutron beamline. This report discusses characterization of the neutron beamline following the addition of fuel to the NRAD. This work includes determination of the facility category according to the American Society for Testing and Materials (ASTM standards, and also uses an array of gold foils to determine the neutron beam flux and evaluate the neutron beam profile. The NRAD ERS neutron beam is a Category I neutron radiography facility, the highest possible quality level according to the ASTM. Gold foil activation experiments show that the average neutron flux with length-to-diameter ratio (L/D = 125 is 5.96 × 106 n/cm2/s with a 2σ standard error of 2.90 × 105 n/cm2/s. The neutron beam profile can be considered flat for qualitative neutron radiographic evaluation purposes. However, the neutron beam profile should be taken into account for quantitative evaluation.

  19. Water movement near the soybean root by neutron radiography

    International Nuclear Information System (INIS)

    Makino-Nakanishi, Tomoko; Matsumoto, Satoshi; Tsuruno, Akira.

    1994-01-01

    Neutron radiography (NR) was applied to investigate the water movement in soil during the growth of the soybean plant, non-destructively. The plant was grown in a thin aluminum container and was set to the cassete where an X-ray film and a gadrinium converter were sealed in vacuum. Periodically, the sample was taken to the nuclear reactor, JRR-3, installed at Japan Atomic Energy Research Institute. Total neutron flux irradiated was 1.9 x 10 7 n/cm 2 . After irradiation the X-ray film was developed and the sample image was scanned to get the water image. The darkness of the image was corresponded well with the water amount and the resolution was found to be about 15 μm. Scanning of the image along with the horizontal line showed that much amount of water in the soil was decreased at the part adjacent to the root, compared to that of 1-2 mm far from the root. It was also shown that there is the unsymmetrical water uptake of the root at the same depth position. To know the water movement, especially around the secondary root, three dimensional water image was depicted. When the secondary root began to develop, the large water movement around the primary root was observed especially at the opposite side of the secondary root. (author)

  20. Combining technologies - radiography and neutron based - for cargo security applications

    International Nuclear Information System (INIS)

    Gozani, T.; Liu, F.; Sivakumar, M.; Brown, D.

    2004-01-01

    Inspection of air and sea cargo has traditionally been done by X-ray systems of various energies relying on operators to analyze images looking for anomalies in the image of cargo that may signify a threat. This has shown only limited success in detecting explosives and other threats, which do not have any distinctive shapes. OSI Systems, through its subsidiaries Rapiscan and Ancore, has combined high-energy x-ray radiography with thermal neutron analysis (TNA) to create the combined system-''TNX''. The system provides automatic material specific detection of bulk threat items, like explosives, while furnishing the operator with a high-resolution image for weapons detection and also to identify anomalies for the TNA to inspect. Similarly the Pulsed Fast Neutron Analysis (PFNA) can be combined with high-energy x-ray to create a ''FNX'' system for both air and sea cargo applications. This enables the operator obtain a three dimensional image of the material composition of the cargo under inspection and remove the clutter from the image leaving only the potentially hazardous material(s) automatically while viewing a high resolution image for manifest verification and weapons. The current status of the technology will be discussed and data be presented

  1. ENEA TRIGA RC-1 reactor activities in the fields of nuclear medicine and neutron radiography

    International Nuclear Information System (INIS)

    Chiesa, Gianni; Festinesi, Armando; Palomba, Mario; Rosa, Roberto; Rossi, Gabriela; Sangiovanni, Gino; Santoro, Emilio; Sedda, Antioco Franco; Storelli, Lucio

    2008-01-01

    In the last three years, TRIGA RC-1 plant staff is involved in collaborations with some roman hospitals for the production of particular radioisotopes for the diagnosis and therapy in the field of human cancer. Further, the thermal column of TRIGA reactor has been prepared for neutron radiography and tomography. For another channel, instruments and equipment above neutron radiography and tomography are in preparation phase. This paper includes an overview of the experimental equipment properly developed by TRIGA staff. (authors)

  2. Inspection of CF188 composite flight control surfaces with neutron radiography

    International Nuclear Information System (INIS)

    Lewis, W.J.; Bennett, L.G.I.; Mullin, S.K.

    1996-01-01

    At the Royal Military College of Canada's SLOWPOKE-2 Facility, a neutron radiography facility has been designed and installed using a small (20kWth), pool-type research reactor called the SLOWPOKE-2 (Safe Low Power c(K)ritical Experiment) as the neutron source. Since then, the research has continued along two fronts: developing applications and improving the quality of the neutron beam. The most interesting applications investigated to date has been the inspection of various metal ceramic composites and the inspection of the composite flight control surfaces of some of the CF188 Hornet aircraft. As part of the determination of the integrity of the aircraft, it was decided to inspect an aircraft with the highest flight house using both X- and neutron radiography. The neutron radiography and, to a lesser extent, X-radiography inspections completed at McClellan AFB revealed 93 anomalies. After returning to Canada, the component with the greatest structural significance, namely the right hand rudder from the vertical stabilizer, was removed from the aircraft and put through a rigorous program of numerous NDT inspections, including X-radiography (film and real-time), eddy current, ultrasonics (through transmission and pitch-catch), infrared thermography, and neutron radiography. Therefore, of all the techniques investigated, only through transmission ultrasonics and neutron radiography were able to identify large areas of hydration. However, only neutron radiography could identify the small areas of moisture and hydration. Given the structural significance of the flight control surfaces in modern fighter aircraft, even the smallest amounts of hydration could potentially lead to catastrophic results

  3. Non destructive testing and neutron radiography in 1994; Les controles non destructifs et la neutronographie en 1994

    Energy Technology Data Exchange (ETDEWEB)

    Bayon, G.

    1994-12-31

    Neutron radiography has been considered for a long time as a promising technique; however it plays a minor part in the world of non destructive testing today, due to the lack of suitable neutron sources and lack of new industrial applications. This paper reviews the present status of neutron sources, neutron radiography activities, especially in France (such as the neutron-capture-issued secondary radiation spectrometry), in nuclear, aerospace, aeronautical and metallurgical sectors, and the last applications of neutron dynamic imaging. 9 refs.

  4. A light, superconducting H- cyclotron for medical diagnostics and neutron radiography

    International Nuclear Information System (INIS)

    Finlan, M.F.; Kruip, M.; Wilson, M.N.

    1987-01-01

    Oxford Instruments, working in close collaboration with Amersham International are developing a compact, lightweight, low radiation field superconducting cyclotron. The combination of superconductivity, H - acceleration and no internal yoke as such makes this possible. It is intended for use as a generator of short half lived isotopes for use in hospitals for PET and other imaging procedures, for use in industrial PET imaging, and as a neutron generator for neutron radiography. With a weight of 2000 kg, it is transportable and comparitively easy to handle and is capable in the 17 MeV version of generating 1.8 10 13 neutrons/second for neutron radiography. (author)

  5. Characterization of the Annular Core Research Reactor (ACRR Neutron Radiography System Imaging Plane

    Directory of Open Access Journals (Sweden)

    Kaiser Krista

    2016-01-01

    Full Text Available The Annular Core Research Reactor (ACRR at Sandia National Laboratories (SNL is an epithermal pool-type research reactor licensed up to a thermal power of 2.4 MW. The ACRR facility has a neutron radiography facility that is used for imaging a wide range of items including reactor fuel and neutron generators. The ACRR neutron radiography system has four apertures (65:1, 125:1, 250:1, and 500:1 available to experimenters. The neutron flux and spectrum as well as the gamma dose rate were characterized at the imaging plane for the ACRR's neutron radiography system for the 65:1, 125:1 and 250:1 apertures.

  6. EURATOM work on standard defects and dimensional measurements in neutron radiography of nuclear fuel elements

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1981-10-01

    In 1979 a working group on neutron radiography was formed at Euratom. The purpose of this group is the standardization of neutron radiographic methods in the field of nuclear fuel. First priority was given to the development of image quality indicators and standard objects for the determination of accuracy of dimensional measurements from neutron radiographs. For that purpose beam purity and sensitivity indicators as well as a calibration fuel pin were designed and fabricated at Risoe. All the Euratom neutron radiography centers have recieved the above items for comparative neutron radiography. The measuring results obtained, using various measuring apparatus, will form the basis to formulate conclusions about the best measuring methods and instruments to be used in that field. (author)

  7. Archaeometric studies by using neutron radiography in ITU TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, A. Beril

    2008-01-01

    Archaeometric many studies have been done by using neutron radiography in ITU TRIGA Mark-II Training and Research Reactor for over 15 years. Tangential beam tube has been arranged for using neutron radiography. Generally, transfer technique has been preferred with using dysprosium screen, but indium screen also is used. Some studies are described which are all on the Anatolian artefacts. The first study from 13th century AD deals with Seljukian period from south-east Anatolia. It investigated a plate from Great Mosque door in Cizre. With means of the neutron radiography painting traces are investigated on the plates. Organic dye traces are noticed on some of plates, which have generally animal figures. Other studies from Urartu period at the first millennium B.C, investigates artefacts found at the vicinity of Van on east Anatolia. An important one is a sword that was found in a grave. It has some corrosion defects. The neutron radiography was applied and shown that wooden parts are there. Other studies referred to samples from the Ikiztepe Excavation site on north Anatolia. Many artefacts were examined by neutron radiography. Some of them evidenced animal parts are recognised as covering parts. An interesting result was obtained to a sword and its sheath that were corroded together. After the neutron radiography applications, it was noticed that there are a cloth between the sword and its sheath. Hence, it was the cause of corrosion of the artefact. By using neutron radiography, many interesting and detailed results were observed by means of the neutron beam from the ITU TRIGA Mark-II Training and Research Reactor. Some of them could not be evidenced by means of any other technique

  8. Quantifying moisture transport in cementitious materials using neutron radiography

    Science.gov (United States)

    Lucero, Catherine L.

    . It has been found through this study that small pores, namely voids created by chemical shrinkage, gel pores, and capillary pores, ranging from 0.5 nm to 50 microm, fill quickly through capillary action. However, large entrapped and entrained air voids ranging from 0.05 to 1.25 mm remain empty during the initial filling process. In mortar exposed to calcium chloride solution, a decrease in sorptivity was observed due to an increase in viscosity and surface tension of the solution as proposed by Spragg et al 2011. This work however also noted a decrease in the rate of absorption due to a reaction between the salt and matrix which results in the filling of the pores in the concrete. The results from neutron imaging can help in the interpretation of standard absorption tests. ASTM C1585 test results can be further analyzed in several ways that could give an accurate indication of the durability of the concrete. Results can be reported in depth of penetration versus the square root of time rather than mm3 of fluid per mm2 of exposed surface area. Since a known fraction of pores are initially filling before reaching the edge of the sample, the actual depth of penetration can be calculated. This work is compared with an 'intrinsic sorptivity' that can be used to interpret mass measurements. Furthermore, the influence of shrinkage reducing admixtures (SRAs) on drying was studied. Neutron radiographs showed that systems saturated in water remain "wetter" than systems saturated in 5% SRA solution. The SRA in the system reduces the moisture diffusion coefficient due an increase in viscosity and decrease in surface tension. Neutron radiography provided spatial information of the drying front that cannot be achieved using other methods.

  9. A mobile superconducting cyclotron for PET and neutron radiography

    International Nuclear Information System (INIS)

    Griffiths, R.

    1988-01-01

    The report addresses the development of a mobile superconducting cyclotron for PET (positron emission tomography) and neutron radiography. Proposals for an ultralight cyclotron were made by Finlan et al., who suggested a novel technique of utilising a superconducting magnet with RF acceleration and iron sectors contained within the room temperature bore of the magnet. Detailed design of a cyclotron based on this concept has progressed well at Oxford Instruments. The main design priorities were to minimise the weight and power consumption of the cyclotron. The cyclotron required a large amount of shielding to reduce either radiation background levels or stray magnetic field. Thus low background levels of radiation and magnetic field are key design criteria. The superconducting magnet has a mean field of 2.35 Tesla and a room temperature bore diameter of 500 mm. Three pairs of profiled iron sectors placed in the center of the warm bore of the magnet provide an azimuthally varying magnetic field. This permits the use of high beam currents with low background. A novel technique is incorporated to reduce the stray magnetic field and radiation from the cyclotron. The RF system consists of three pairs of resonators mounted within the warm bore of the magnet between the iron sectors. (Nogami, K.)

  10. State of maintenance of JRR-3M neutron radiography facilities

    International Nuclear Information System (INIS)

    Tsuruno, Akira

    1994-01-01

    Nearly two years have elapsed since the use of the JRR-3M neutron radiography facilities was begun. Five years passed since the decision of the detailed specification, and this period is enough for the contained equipment and the peripheral equipment become old-fashioned. In addition, as unexpected high performance was obtained by these facilities, the measures were to be taken in many places. In this fiscal year, the improvement of the contained equipment and the increase of the peripheral equipment were carried out. These improvement and renewal are still insufficient for these facilities demonstrate the performance fully, and are expected to continue hereafter. As the measures taken in relation to the TNRF-2, the renewal of the BN shutter, the remodeling of the black box and the improvement of the interlock were carried out. As the measures taken in relation to CNRF, the new installation of auxiliary shields, the remodeling of the shutter and the new installation of internal illumination were carried out. As the measures taken in relation to the image processor, the outline based on long term perspective is shown. The equipments which were purchased in this fiscal year are the work station which becomes the center of the image-processing network, the cooled CCD camera system and the SIT camera for renewal. In the dark room, a scanning micro-densitometer was installed. (K.I.)

  11. Test and application of thermal neutron radiography facility at Xi'an pulsed reactor

    CERN Document Server

    Yang Jun; Zhao Xiang Feng; Wang Dao Hua

    2002-01-01

    A thermal neutron radiography facility at Xi'an Pulsed Reactor is described as well as its characteristics and application. The experiment results show the inherent unsharpness of BAS ND is 0.15 mm. The efficient thermal neutron n/gamma ratio is lower in not only steady state configuration but also pulsing state configuration and it is improved using Pb filter

  12. Conversion from film to image plates for transfer method neutron radiography of nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Craft, Aaron E.; Papaioannou, Glen C.; Chichester, David L.; Williams, Walter J.

    2017-02-01

    This paper summarizes efforts to characterize and qualify a computed radiography (CR) system for neutron radiography of irradiated nuclear fuel at Idaho National Laboratory (INL). INL has multiple programs that are actively developing, testing, and evaluating new nuclear fuels. Irradiated fuel experiments are subjected to a number of sequential post-irradiation examination techniques that provide insight into the overall behavior and performance of the fuel. One of the first and most important of these exams is neutron radiography, which provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Results from neutron radiography are often the driver for subsequent examinations of the PIE program. Features of interest that can be evaluated using neutron radiography include irradiation-induced swelling, isotopic and fuel-fragment redistribution, plate deformations, and fuel fracturing. The NRAD currently uses the foil-film transfer technique with film for imaging fuel. INL is pursuing multiple efforts to advance its neutron imaging capabilities for evaluating irradiated fuel and other applications, including conversion from film to CR image plates. Neutron CR is the current state-of-the-art for neutron imaging of highly-radioactive objects. Initial neutron radiographs of various types of nuclear fuel indicate that radiographs can be obtained of comparable image quality currently obtained using film. This paper provides neutron radiographs of representative irradiated fuel pins along with neutron radiographs of standards that informed the qualification of the neutron CR system for routine use. Additionally, this paper includes evaluations of some of the CR scanner parameters and their effects on image quality.

  13. Quantitative density measurements from a real-time neutron radiography system

    International Nuclear Information System (INIS)

    McRae, D.D.; Jenkins, R.W. Jr.; Brenizer, J.S.; Tobin, K.W.; Hosticka, B.; Sulcoski, M.F.

    1986-01-01

    An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation

  14. Industrial applications at the new cold neutron radiography and tomography facility of the HMI

    International Nuclear Information System (INIS)

    Kardjilov, N.; Hilger, A.; Manke, I.; Strobl, M.; Treimer, W.; Banhart, J.

    2005-01-01

    The new cold neutron radiography and tomography facility at the Hahn-Meitner-Institut Berlin is suited for the investigation of components and materials from different industrial fields. The high-flux measuring position of the facility allows real-time imaging of fast dynamical processes. Cold neutrons interact stronger with the matter compared to thermal neutrons, which leads to a much better radiography contrast. Some examples of different industry applications like investigations on discharging of a Lithium battery or on oil sediments in a vent pipe are presented

  15. Neutron radiography activity in the european program cost 524: Neutron imaging techniques

    International Nuclear Information System (INIS)

    Chirco, P.; Bach, P.; Lehmann, E.; Balasko, M.

    2001-01-01

    COST is a framework for scientific and technical cooperation, allowing the coordination of national research on a European level, including 32 member countries. Participation of institutes from non-COST countries is possible. From an initial 7 Actions in 1971, COST has grown to 200 Actions at the beginning of 2000. COST Action 524 is under materials domain, the title of which being 'Neutron Imaging Techniques for the Detection of Defects in Materials', under the Chairmanship of Dr. P. Chirco (I.N.F.N.). The following countries are represented in the Management Committee of Action 524: Italy, France, Austria, Germany, United Kingdom, Hungary, Switzerland, Spain, Czech Republic, Slovenia, and Russia. The six working groups of this Action are working respectively on standardization of neutron radiography techniques, on aerospace application, on civil engineering applications, on comparison and integration of neutron imaging techniques with other NDT, on neutron tomography, and on non radiographic techniques such as neutron scattering techniques. A specific effort is devoted to standardization issues, with respect to other non European standards. Results of work performed in the COST frame are published or will be published in the review INSIGHT, edited by the British Institute of Non Destructive Testing

  16. Modification of NUR II neutron beam profile of MINT TRIGA MARK II research reactor for digital neutron radiography

    International Nuclear Information System (INIS)

    Muhammad Rawi Mohamed Zin; Azali Muhammad; Abdul Aziz Mohamed; Rafhayudi Jamro; Syed Nasaruddin Syed Idris; Ng Aik Hao; Rosly Jaafar

    2006-01-01

    A cone neutron beam collimated by a 5.4 cm aperture produced in the Neutron Radiography II (NUR II) via a step divergence collimator had to be modified to fulfill 5 cm x 6 cm dimension of the scintillation screen placed in the charge couple device (ccd) camera. The required convergence neutron beam was obtained by a simple collimator-beam plug plugged in front of the NUR II beam port. The calculations involved in designing the collimator-beam plug had to take into account not only the neutron beam profiling but also the neutron and gamma shielding and are discussed in this article. (Author)

  17. Evolution of the nondestructive testing equipment for neutron radiography in the framework of the programs of the Services des Piles de Saclay

    International Nuclear Information System (INIS)

    1980-10-01

    The progress made in neutron radiography testing equipment is made with respect to (a) the devices located inside reactor ponds (collimation, leak-tightness, irradiation devices, detection systems), (b) neutron radiography of active parts outside the reactor ponds (testing of fuel rods several metres long by a neutron radiography system by dry feed through), (3) neutron radiography on inactive materials (fitting an axial channel and a side channel in the Triton reactor), (4) neutron radiography on a neutron guide set up at the end of the Neutron Guide Hall associated with the Orphee reactor, i.e. 70 metres from it [fr

  18. MTF analysis of the MURR real-time neutron radiography facility

    International Nuclear Information System (INIS)

    Lindsay, J.T.

    1982-01-01

    In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a knife-edge, differentiate the edge gradient to obtain the line spread function (LSF) to obtain the system MTF. A Gd foil was used for the knife-edge on several neutron converter screens and was imaged by a low-light level ISIT camera. The video signal was then digitized and presented to a PDP-11/05 microcomputer for the numerical calculations

  19. Neutron radiography imaging with 2-dimensional photon counting method and its problems

    International Nuclear Information System (INIS)

    Ikeda, Y.; Kobayashi, H.; Niwa, T.; Kataoka, T.

    1988-01-01

    A ultra sensitive neutron imaging system has been deviced with a 2-dimensional photon counting camara (ARGUS 100). The imaging system is composed by a 2-dimensional single photon counting tube and a low background vidicon followed with an image processing unit and frame memories. By using the imaging system, electronic neutron radiography (NTV) has been possible under the neutron flux less than 3 x 10 4 n/cm 2 ·s. (author)

  20. Improvement of neutron collimator design for thermal neutron radiography using Monte Carlo N-particle transport code version 5

    International Nuclear Information System (INIS)

    Thiagu Supramaniam

    2007-01-01

    The aim of this research was to propose a new neutron collimator design for thermal neutron radiography facility using tangential beam port of PUSPATI TRIGA Mark II reactor, Malaysia Institute of Nuclear Technology Research (MINT). Best geometry and materials for neutron collimator were chosen in order to obtain a uniform beam with maximum thermal neutron flux, high L/ D ratio, high neutron to gamma ratio and low beam divergence with high resolution. Monte Carlo N-particle Transport Code version 5 (MCNP 5) was used to optimize six neutron collimator components such as beam port medium, neutron scatterer, neutron moderator, gamma filter, aperture and collimator wall. The reactor and tangential beam port setup in MCNP5 was plotted according to its actual sizes. A homogeneous reactor core was assumed and population control method of variance reduction technique was applied by using cell importance. The comparison between experimental results and simulated results of the thermal neutron flux measurement of the bare tangential beam port, shows that both graph obtained had similar pattern. This directly suggests the reliability of MCNP5 in order to obtained optimal neutron collimator parameters. The simulated results of the optimal neutron medium, shows that vacuum was the best medium to transport neutrons followed by helium gas and air. The optimized aperture component was boral with 3 cm thickness. The optimal aperture center hole diameter was 2 cm which produces 88 L/ D ratio. Simulation also shows that graphite neutron scatterer improves thermal neutron flux while reducing fast neutron flux. Neutron moderator was used to moderate fast and epithermal neutrons in the beam port. Paraffin wax with 90 cm thick was bound to be the best neutron moderator material which produces the highest thermal neutron flux at the image plane. Cylindrical shape high density polyethylene neutron collimator produces the highest thermal neutron flux at the image plane rather than divergent

  1. Morphological identification of not growing bacteria for neutron radiography

    International Nuclear Information System (INIS)

    Lopes, J.D.R.; Crispim, V.R.; Pessolani, M.C.V.

    2008-01-01

    The technological development associate the new discoveries in the genetic field, has contributed for an improvement in the diagnosis of determined illnesses, however the laboratories analysis nor always are carried through in desired the minimum time and precision, beyond not being optimized the financial resources. The result of these controversies can lead the loss of possibilities of overlife of the patients, taking them, also to the death. At present time, exist an expensive equipment capable to identify fastly a commons bacteria. However, to achieve reliable diagnostics, microorganisms have to grow in appropriate culture media before identification, what sometimes can take a great amount of time, making it difficult the diagnosis. Some of them, also, are not growing in artificial nutrients, being possible only its diagnosis after an inoculation carried through in laboratory guinea pigs, as in the case of the Mycobacterium leprae. Neutron radiography has been used for several years as a non-destructive technique with several applications. Giving credit itself the potentiality of this technique for the faster identification of bacteria in comparison with the conventional microbiological techniques, because there's no need for the overnight cultures. In this work was decided to proceed to the evaluation of the technique and the determination of the involved parameters. The work had demonstrated that the method can come to be promising, as a method auxiliary to already the existing ones, it is intended to give to continuity the research concentrating itself in the evaluation of the method for application in hemocultures and administer it in the diagnosis of bacteria that not growing in artificial ways, such as the Mycobacterium leprae. (author)

  2. Time resolved analysis of water drainage in porous asphalt concrete using neutron radiography.

    Science.gov (United States)

    Poulikakos, L D; Sedighi Gilani, M; Derome, D; Jerjen, I; Vontobel, P

    2013-07-01

    Porous asphalt as a road surface layer controls aquaplaning as rain water can drain through its highly porous structure. The process of water drainage through this permeable layer is studied using neutron radiography. Time-resolved water configuration and distribution within the porous structure are reported. It is shown that radiography depicts the process of liquid water transport within the complex geometry of porous asphalt, capturing water films, filled dead end pores and water islands. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Neutron beam applications - A development of real-time imaging processing for neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Whoi Yul; Lee, Sang Yup; Choi, Min Seok; Hwang, Sun Kyu; Han, Il Ho; Jang, Jae Young [Hanyang University, Seoul (Korea)

    1999-08-01

    This research is sponsored and supported by KAERI as a part of {sup A}pplication of Neutron Radiography Beam.{sup M}ain theme of the research is to develop a non-destructive inspection system for the task of studying the real-time behaviour of dynamic motion using neutron beam with the aid of a special purpose real-time image processing system that allows to capture an image of internal structure of a specimen. Currently, most off-the-shelf image processing programs designed for visible light or X-ray are not adequate for the applications that require neutron beam generated by the experimental nuclear reactor. In addition, study of dynamic motion of a specimen is severely constrained by such image processing systems. In this research, a special image processing system suited for such application is developed which not only supplements the commercial image processing system but allows to use neutron beam directly in the system for the study. 18 refs., 21 figs., 1 tab. (Author)

  4. Development of a transportable neutron radiography system for non-destructive tests application

    International Nuclear Information System (INIS)

    Silva, Ademir X. da; Crispim, Verginia R.

    1999-01-01

    This paper presents a study of a transportable neutron radiography system utilizing californium-252. Studies about moderation, collimation and shielding are showed. A Monte Carlo Code, MCNP3b, has been used to obtain a maximum and more homogeneous thermal neutron flux in the collimator outlet next to the image plain, and an adequate radiation shielding to attend radiological protection rules. With the presented collimator, it was possible to obtain for the thermal neutron flux, at the collimator outlet and next to the image plain, a L/D ratio 7,5, for neutron flux up to 6 X 10 -6 cm -2 .s -1 per neutron source. (author)

  5. A new CCD-camera neutron radiography detector at the Atominstitute of the Austrian Universities

    International Nuclear Information System (INIS)

    Koerner, S.; Boeck, H.; Rauch, H.; Lehmann, E.

    1999-01-01

    Neutron radiography provides a very efficient tool for non-destructive testing as well as for many applications in fundamental research. A neutron beam penetrating a specimen is attenuated by the sample material and detected by a two dimensional imaging device. The image contains information about materials and structure inside the sample because neutrons are attenuated according to the basic law of radiation attenuation. At the Atominstitute of the Austrian Universities neutron radiographic examinations have been carried out for more than 35 years, mainly with detectors consisting of X-ray films and a Gd- converter enclosed in a vacuum cassette. Presently a neutron tomography set-up is under development. For high quality 3D image reconstruction, about 200 digitized neutron transmission images from different angles of the object are necessary. Therefore the first step was the design of an adequate electronic neutron radiography imaging device. The requirements for a detector suitable for neutron tomography are: exact and reproducible positioning, easy handling, high spatial resolution and dynamic range, high efficiency and a good linearity. The key components of the detector system selected on the basis of the requirements consist of a neutron sensitive scintillator screen, a cooled slow scan CCD camera and a mirror to reflect the light emitted by the scintillator to the CCD camera. The whole assembly is placed in a light tight enclosure. In this paper the strategy of the selection of the individual detector components is described. Comparisons on the influence of the use of different components on the properties of the whole position sensitive imaging device are demonstrated. Finally the new CCD camera neutron radiography detector of the Atominstitute is presented and first results of test measurements performed at the neutron radiography facility NEUTRA at the continuous spallation source SINQ at Paul Scherrer Institute are shown.(author)

  6. Fast neutron radiography testing for components of launch vehicles by a baby-cyclotron

    International Nuclear Information System (INIS)

    Ikeda, Y.; Ohkubo, K.; Matsumoto, G.; Nakamura, T.; Nozaki, Y.; Wakasa, S.; Toda, Y.; Kato, T.

    1990-01-01

    Recently, neutron radiography (NR) has become an important means of nondestructive testing (NDT) in Japan. Especially thermal neutron radiography testing (NRT) has been used for the NDT of various explosive devices of launch vehicles, which are developed as a H-series program by the National Space Development Agency (NASDA) of Japan. The NRT for launch vehicles has been carried out at the NR facility of a baby-cyclotron. In the NRT a conventional film method based on silver-halide emulsion has been exclusively employed to inspect various testing objects including components, and many valuable results have been obtained so far successfully. However, recently, the launch vehicles to be shot up have become much larger. With larger launch vehicles, the parts used in them have also become larger and thicker. One main disadvantage of the NRT by thermal neutrons is somewhat weak penetrability through objects because the energy is small. With the conventional thermal neutron radiography (TNR), steel objects being thicker than 40 to 50 mm are difficult to test through them because scattered neutrons obstruct real image of the object. Consequently a new method of NRT should be developed instead of TNR and applied to the new components of H-2 launch vehicles. In order to cope with the requirement, fast neutron radiography (FNR) has been studied for testing the new components of H-2, such as large separation bolts

  7. Swelling behavior detection of irradiated U-10Zr alloy fuel using indirect neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yong; Huo, He-yong; Wu, Yang [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Key Laboratory of Neutron Physics, Chinese Academy of Engineering Physics, Mianyang (China); Li, Jiangbo [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Zhou, Wei; Guo, Hai-bing [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Key Laboratory of Neutron Physics, Chinese Academy of Engineering Physics, Mianyang (China); Li, Hang, E-mail: lihang32@gmail.com [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Key Laboratory of Neutron Physics, Chinese Academy of Engineering Physics, Mianyang (China); Cao, Chao; Yin, Wei; Wang, Sheng; Liu, Bin; Feng, Qi-jie; Tang, Bin [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Key Laboratory of Neutron Physics, Chinese Academy of Engineering Physics, Mianyang (China)

    2016-11-21

    It is hopeful that fusion-fission hybrid energy system will become an effective approach to achieve long-term sustainable development of fission energy. U-10Zr alloy (which means the mass ratio of Zr is 10%) fuel is the key material of subcritical blanket for fusion-fission hybrid energy system which the irradiation performance need to be considered. Indirect neutron radiography is used to detect the irradiated U-10Zr alloy because of the high residual dose in this paper. Different burnup samples (0.1%, 0.3%, 0.5% and 0.7%) have been tested with a special indirect neutron radiography device at CMRR (China Mianyang Research Reactor). The resolution of the device is better than 50 µm and the quantitative analysis of swelling behaviors was carried out. The results show that the swelling behaviors relate well to burnup character which can be detected accurately by indirect neutron radiography.

  8. The development of neutron radiography and its potential application in Malaysia

    International Nuclear Information System (INIS)

    Azali Muhammad

    1994-01-01

    The development of neutron radiography in Malaysia started with the availability of the country's first research reactor. The 1MW reactor was commissioned in June 1982, mainly for research purposes and the development of neutron radiography was one of the main application. In late 1983, a neutron radiography test facility known as NuR-1 was constructed out of small modular concrete blocks. Tests carried out in this facility enabled the design of the permanent facility known as NuR-2 to be finalised. The construction of NuR-2 took place in November 1984 and was completed in February 1985. In January 1987, a new collimator was installed in NuR-2 and direct exposure method was successfully performed using gadolinium metal converter and Kodak SR film. This facility will be used to solve specific problems in the field of air-craft, explosive, electronic and rubber industries, and also some research programs in biology

  9. FMCEIR: a Monte Carlo program for solving the stationary neutron and gamma transport equation

    International Nuclear Information System (INIS)

    Taormina, A.

    1978-05-01

    FMCEIR is a three-dimensional Monte Carlo program for solving the stationary neutron and gamma transport equation. It is used to study the problem of neutron and gamma streaming in the GCFR and HHT reactor channels. (G.T.H.)

  10. Investigation of microporosity in die-cast AlSi12(Cu) alloys by neutron- and X-ray radiography

    International Nuclear Information System (INIS)

    Zsolt, S.; Marton, B.

    1999-01-01

    The porosity of the casting can dramatically reduce the solidity and reliability of the objects made from aluminum alloys. The X-ray radiography is able to find the placement of the porosity of the aluminum devices. After a special 'water saturation' process the dynamic neutron radiography is available to discover the 'dangerous' surface nearporosity in the aluminum samples. The X-ray and neutron radiography were used as complementary examination techniques to study the porosity of the aluminum castings.(author)

  11. Non-destructive test of lock actuator component using neutron radiography technique

    International Nuclear Information System (INIS)

    Juliyanti; Setiawan; Sutiarso

    2012-01-01

    Non-destructive test of lock actuator using neutron radiography technique has been done. The lock actuator is a mechanical system which is controlled by central lock module consisting of electronic circuit which drives the lock actuator works accordingly to open and lock the vehicle door. The non-destructive test using neutron radiography is carried out to identify the type of defect is presence by comparing between the broken and the brand new one. The method used to test the lock actuator component is film method (direct method). The result show that the radiography procedure has complied with the ASTM standard for neutron radiography with background density of 2.2, 7 lines and 3 holes was seen in the sensitivity indicator (SI) and the quite good image quality was obtained. In the brand new actuator is seen that isolator part which separated the coils has melted. By this non-destructive test using neutron radiography technique is able to detect in early stage the type of component's defect inside the lock actuator without to dismantle it. (author)

  12. Characterization and adjustment of the neutron radiography facility of the RP-10 nuclear reactor

    International Nuclear Information System (INIS)

    Ravello R, Y.R.

    2001-01-01

    The main aim of this work was to characterize and adjust the neutron radiography facility of the RP-10 nuclear reactor, and therefore be able to offer with this technique services to the industry and research centers in general. This technique will be complemented with others such as x-rays and gamma radiography. First, the shielding capacity of the facility was analyzed, proving that it complies with the radiological safety requirements established by the radiological safety code. Then gamma filtration tests were conducted in order to implement the direct method for image formation, optical density curves were built according to the thickness of the gamma filter, the type of film and the type of irradiation. Also, the indirect method for image formation was implemented for two types of converters: indium and dysprosium. Growth curves for optical density were also made according to contact time between converter-film, for different types of films. The resolution of the facility was also analyzed using two methods: Klasens (1946) and Harms (1986). Harms method came closer to the resolution of the human eye when compared to the Klasens method. Finally, the application fields of neutron radiography are presented, including those conducted at the neutron radiography facility of the RP-10 nuclear reactor. With this work, the RP-10 neutron radiography facility is ready to offer inspection and research services

  13. Corrections on energy spectrum and scattering for fast neutron radiography at NECTAR facility

    International Nuclear Information System (INIS)

    Liu Shuquan; Thomas, Boucherl; Li Hang; Zou Yubin; Lu Yuanrong; Guo Zhiyu

    2013-01-01

    Distortions caused by the neutron spectrum and scattered neutrons are major problems in fast neutron radiography and should be considered for improving the image quality. This paper puts emphasis on the removal of these image distortions and deviations for fast neutron radiography performed at the NECTAR facility of the research reactor FRM-Ⅱ in Technische Universitaet Mounchen (TUM), Germany. The NECTAR energy spectrum is analyzed and established to modify the influence caused by the neutron spectrum, and the Point Scattered Function (PScF) simulated by the Monte-Carlo program MCNPX is used to evaluate scattering effects from the object and improve image quality. Good analysis results prove the sound effects of the above two corrections. (authors)

  14. Corrections on energy spectrum and scatterings for fast neutron radiography at NECTAR facility

    Science.gov (United States)

    Liu, Shu-Quan; Bücherl, Thomas; Li, Hang; Zou, Yu-Bin; Lu, Yuan-Rong; Guo, Zhi-Yu

    2013-11-01

    Distortions caused by the neutron spectrum and scattered neutrons are major problems in fast neutron radiography and should be considered for improving the image quality. This paper puts emphasis on the removal of these image distortions and deviations for fast neutron radiography performed at the NECTAR facility of the research reactor FRM- II in Technische Universität München (TUM), Germany. The NECTAR energy spectrum is analyzed and established to modify the influence caused by the neutron spectrum, and the Point Scattered Function (PScF) simulated by the Monte-Carlo program MCNPX is used to evaluate scattering effects from the object and improve image quality. Good analysis results prove the sound effects of the above two corrections.

  15. Image enhancement using MCNP5 code and MATLAB in neutron radiography.

    Science.gov (United States)

    Tharwat, Montaser; Mohamed, Nader; Mongy, T

    2014-07-01

    This work presents a method that can be used to enhance the neutron radiography (NR) image for objects with high scattering materials like hydrogen, carbon and other light materials. This method used Monte Carlo code, MCNP5, to simulate the NR process and get the flux distribution for each pixel of the image and determines the scattered neutron distribution that caused image blur, and then uses MATLAB to subtract this scattered neutron distribution from the initial image to improve its quality. This work was performed before the commissioning of digital NR system in Jan. 2013. The MATLAB enhancement method is quite a good technique in the case of static based film neutron radiography, while in neutron imaging (NI) technique, image enhancement and quantitative measurement were efficient by using ImageJ software. The enhanced image quality and quantitative measurements were presented in this work. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Fundamental research on isotherm capillary absorption of concrete by neutron radiography

    International Nuclear Information System (INIS)

    Kanematsu, Manabu; Tsuchiya, Naoko; Noguchi, Takafumi

    2013-01-01

    This study focuses on the absorption process of concrete to determine the influence of aggregates on the local water behavior in concrete, by using neutron radiography. At first, water quantification method by using thermal neutron radiography is summarized which is developed in previous researches. With this method, the water absorption process was examined in concrete specimens containing artificial cylindrical aggregates. Using the obtained hydraulic diffusivity, an unsteady water diffusion analysis captured the experimentally observed water distribution around the aggregates. The result shows that the water behavior can be well explained by the geometric layout of the aggregates. (author)

  17. Modernization design of neutron radiography of ITU TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, B.; Bilge, A.N.

    1988-01-01

    ITU TRIGA MARK-II Research and Training Reactor has a power of 250 KW and has three beam tubes. One of them is tangential beam tube used for neutron radiography. In this study, the neutron radiography set in the tangential beam tube is described with its problems for ITU TRIGA Reactor. After that modernization of the system is designed and the applicability of the direct and indirect methods is evaluated. Improving the ratio of length to diameter for the beam tube, elimination the fogging on the film and constructive design for practice and secure application of the technique is developed. (author)

  18. Image enhancement using MCNP5 code and MATLAB in neutron radiography

    International Nuclear Information System (INIS)

    Tharwat, Montaser; Mohamed, Nader; Mongy, T.

    2014-01-01

    This work presents a method that can be used to enhance the neutron radiography (NR) image for objects with high scattering materials like hydrogen, carbon and other light materials. This method used Monte Carlo code, MCNP5, to simulate the NR process and get the flux distribution for each pixel of the image and determines the scattered neutron distribution that caused image blur, and then uses MATLAB to subtract this scattered neutron distribution from the initial image to improve its quality. This work was performed before the commissioning of digital NR system in Jan. 2013. The MATLAB enhancement method is quite a good technique in the case of static based film neutron radiography, while in neutron imaging (NI) technique, image enhancement and quantitative measurement were efficient by using ImageJ software. The enhanced image quality and quantitative measurements were presented in this work. - Highlights: • This work is applicable for static based film neutron radiography and digital neutron imaging. • MATLAB is a useful tool for imaging enhancement in radiographic film. • Advanced imaging processing is available in the ETRR-2 for imaging processing and data extraction. • The digital imaging system is suitable for complex shapes and sizes, while MATLAB technique is suitable for simple shapes and sizes. • Quantitative measurements are available

  19. Design, construction and characterization of a new neutron beam for neutron radiography at the Tehran Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Choopan Dastjerdi, M.H., E-mail: mdastjerdi@aeoi.org.ir [Reactor Research School, Nuclear Science and Technology Research Institute, Atomic Energy Organization of Iran, Tehran (Iran, Islamic Republic of); Department of Energy Engineering and Physics, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Khalafi, H.; Kasesaz, Y.; Mirvakili, S.M.; Emami, J.; Ghods, H.; Ezzati, A. [Reactor Research School, Nuclear Science and Technology Research Institute, Atomic Energy Organization of Iran, Tehran (Iran, Islamic Republic of)

    2016-05-11

    To obtain a thermal neutron beam for neutron radiography applications, a neutron collimator has been designed and implemented at the Tehran Research Reactor (TRR). TRR is a 5 MW open pool light water moderated reactor with seven beam tubes. The neutron collimator is implemented in the E beam tube of the TRR. The design of the neutron collimator was performed using MCNPX Monte Carlo code. In this work, polycrystalline bismuth and graphite have been used as a gamma filter and an illuminator, respectively. The L/D parameter of the facility was chosen in the range of 150–250. The thermal neutron flux at the image plane can be varied from 2.26×10{sup 6} to 6.5×10{sup 6} n cm{sup −2} s{sup −1}. Characterization of the beam was performed by ASTM standard IQI and foil activation technique to determine the quality of neutron beam. The results show that the obtained neutron beam has a good quality for neutron radiography applications.

  20. Bone structure investigation using X-ray and neutron radiography techniques

    International Nuclear Information System (INIS)

    Kamali Moghaddam, K.; Taheri, T.; Ayubian, M.

    2008-01-01

    In this paper we report a study of the periodic variation of bone tissue humidity immediately after death using both neutron and X-ray radiography techniques. After death, bone tissue experiences sequential change over time. This change consists of organic and inorganic phase variations of the bone structure, as well as gradual reduction of the bone's water content. These variations are investigated by periodically imaging dead bone using X-ray and neutron radiography. Chemical separation techniques such as calcification and decalcification were used to separate the organic and inorganic phases of the bone. Comparison between X-ray and neutron radiographs of bone following phase separation can be potentially used to investigate the bone disease or to determine a cause of death. In our experiments, we use adult rat femur bones, and the interpretations of these results are presented based on our understanding of bone structure and images produced by neutron and X-ray photon interactions

  1. Bone structure investigation using X-ray and neutron radiography techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kamali Moghaddam, K. [Nuclear Research Center (NRC), Atomic Energy Organization of Iran (AEOI), P.O. Box 11365-8486, Tehran (Iran, Islamic Republic of)], E-mail: kkamali@aeoi.org.ir; Taheri, T.; Ayubian, M. [Nuclear Research Center (NRC), Atomic Energy Organization of Iran (AEOI), P.O. Box 11365-8486, Tehran (Iran, Islamic Republic of)

    2008-01-15

    In this paper we report a study of the periodic variation of bone tissue humidity immediately after death using both neutron and X-ray radiography techniques. After death, bone tissue experiences sequential change over time. This change consists of organic and inorganic phase variations of the bone structure, as well as gradual reduction of the bone's water content. These variations are investigated by periodically imaging dead bone using X-ray and neutron radiography. Chemical separation techniques such as calcification and decalcification were used to separate the organic and inorganic phases of the bone. Comparison between X-ray and neutron radiographs of bone following phase separation can be potentially used to investigate the bone disease or to determine a cause of death. In our experiments, we use adult rat femur bones, and the interpretations of these results are presented based on our understanding of bone structure and images produced by neutron and X-ray photon interactions.

  2. Neutron radiography and other NDE tests of main rotor helicopter blades

    International Nuclear Information System (INIS)

    Beer, F.C. de; Coetzer, M.; Fendeis, D.; Silva, A. da Costa E

    2004-01-01

    A few nondestructive examination (NDE) techniques are extensively being used worldwide to investigate aircraft structures for all types of defects. The detection of corrosion and delaminations, which are believed to be the major initiators of defects leading to aircraft structural failures, are addressed by various NDE techniques. In a combined investigation by means of visual inspection, X-ray radiography and shearography on helicopter main rotor blades, neutron radiography (NRad) at SAFARI-1 research reactor operated by Necsa, was performed to introduce this form of NDE testing to the South African aviation industry to be evaluated for applicability. The results of the shearography, visual inspection and NRad techniques are compared in this paper. The main features and advantages of neutron radiography, within the framework of these investigations, will be highlighted

  3. Measurement of Liquid-Metal Two-Phase Flow with a Dynamic Neutron Radiography

    International Nuclear Information System (INIS)

    Cha, J. E.; Lim, I. C.; Kim, H. R.; Kim, C. M.; Nam, H. Y.; Saito, Y.

    2005-01-01

    The dynamic neutron radiography(DNR) has complementary characteristics to X-ray radiography and is suitable to visualization and measurement of a multi-phase flow research in a metallic duct and liquid metal flow. The flow-field information of liquid metal system is very important for the safety analysis of fast breeder reactor and the design of the spallation target of accelerator driven system. A DNR technique was applied to visualize the flow field in the gas-liquid metal two-phase flow with the HANARO-beam facility. The lead bismuth eutectic and the nitrogen gas were used to construct the two-phase flow field in the natural circulation U-channel. The two-phase flow images in the riser were taken at various combinations of the liquid flow and gas flow with high frame-rate neutron radiography at 1000 fps

  4. Assessing cadmium distribution applying neutron radiography in moss trophical levels, located in Szarvasko, Hungary

    Energy Technology Data Exchange (ETDEWEB)

    Varga, J.; Koroesi, F. E-mail: fkorosi@hotmail.com; Balasko, M. E-mail: balasko@sunserv.kfki.hu; Naar, Z

    2004-10-01

    The measuring station of the 10 MW VVR-SM research reactor at the Budapest Neutron Centre (Hungary) was used to perform dynamic neutron radiography (DNR), which was, to our best knowledge, the first time, in a Tortella tortuosa biotope. In the conducted study, two trophical levels, moss and spider Thomisidae sp. juv., were examined. Cadmium penetration routes, distribution and accumulation zones were visualized in the leafy gametophyte life cycle of Tortella tortuosa and in the organs of the spider.

  5. Application of neutron radiography to the nondestructive testing of fuel elements before and after irradiation

    International Nuclear Information System (INIS)

    Barbalat, R.; Bayon, G.; Laporte, A.

    1983-12-01

    The neutron radiography installations of Saclay using collimated neutron sources from reactors for non-destructive testing of nuclear fuels and components of the nuclear industry are described. The first installation in a pool for experimental devices before, during and after irradiation near the core allowing imaging of highly radioactive materials. The second, a dry installation, is used for monitoring active fuel elements. The last is used for inactive materials coming from industry [fr

  6. Studies review and exploration purpose of neutron radiography technique in the TRIGA IPR-R1 reactor at CDTN, Brazil

    International Nuclear Information System (INIS)

    Costa, Antonella Lombardi; Amorim, Valter Alves de; Stasiulevicius, Roberto; Rocha, Zildete

    2002-01-01

    Neutron Radiography - NR - consists of obtaining on a sensitive plate, the image produced by neutron flux after crossing an object. Through NR is possible to inspect plastics and explosives materials and organic composition. Is difficult to analyze these materials by the radiography technique. The neutron beam extractor was installed, in the TRIGA IPR-R1 reactor at the CDTN. This work presents preliminaries results of the NR researches in the past at CDTN, which are being retaken. (author)

  7. Composite structure of helicopter rotor blades studied by neutron- and X-ray radiography

    International Nuclear Information System (INIS)

    Balasko, M.; Veres, I.; Molnar, Gy.; Balasko, Zs.; Svab, E.

    2004-01-01

    In order to inspect the possible defects in the composite structure of helicopter rotor blades combined neutron- and X-ray radiography investigations were performed at the Budapest Research Reactor. Imperfections in the honeycomb structure, resin rich or starved areas at the core-honeycomb surfaces, inhomogeneities at the adhesive filling and water percolation at the sealing interfaces of the honeycomb sections were discovered

  8. Composite structure of helicopter rotor blades studied by neutron- and X-ray radiography

    Science.gov (United States)

    Balaskó, M.; Veres, I.; Molnár, Gy.; Balaskó, Zs.; Sváb, E.

    2004-07-01

    In order to inspect the possible defects in the composite structure of helicopter rotor blades combined neutron- and X-ray radiography investigations were performed at the Budapest Research Reactor. Imperfections in the honeycomb structure, resin rich or starved areas at the core-honeycomb surfaces, inhomogeneities at the adhesive filling and water percolation at the sealing interfaces of the honeycomb sections were discovered.

  9. Development and investigation of a neutron radiography imaging system with a low-pressure multistep chamber

    International Nuclear Information System (INIS)

    Anisimov, Yu.S.; Chernenko, S.P.; Ivanov, A.B.; Netusil, T.; Peshekhonov, V.D.; Smykov, L.P.; Zanevsky, Yu.V.; Cisar, M.; Horacek, J.; Knourek, J.; Moucka, L.; Nezmar, L.; Pellar, L.; Pochman, J.; Schneider, Z.; Sidak, Z.; Vrba, I.; Bizek, V.; Zavadil, Z.; Beran, P.; Cerny, K.

    1988-01-01

    An imaging system of thermal neutrons for an investigation of digital neutron radiography has been developed and tested. Some characteristics obtained on a neutron radiography beam of an experimental reactor are reported. The coordinates of each event are determined in this system. After processing in a LSI 11/23 computer, a radiograph, accumulated in a histogramming memory of 64 K 16-bit words, is presented on a colour display. A 230x180 mm 2 low-pressure multistep chamber is used as a detector. Neutron conversion takes place in a 6 μm boron layer enriched to 86% in 10 B. The detection efficiency of thermal neutrons is no less than 3%. The count rate of the system reaches up to 2x10 5 events per second. A radiograph can be obtained within 10 minutes. The sensitivity of this system to gamma-background is low. One event/s is detected for a background of 1 R/h. The spatial resolution is found to be 0.7 mm (FWHM) using a cadmium knife edge. The integral nonlinearity is less than 0.4%. The possibility of using a hydrogeneous converter in this system for neutron radiography is discussed. (orig.)

  10. Redesign, construction and characterization of the new neutron radiography facility of the RA-6

    International Nuclear Information System (INIS)

    Marin, J.; Sanchez, F.A.; Blaumann, H.

    2012-01-01

    Neutron radiography is a non-destructive test in which it is registered an image of the attenuation experienced by a collimated neutron beam while it passes through a sample. The image is generated by using a neutron-sensitive screen. The applications of this technique are wide, some of them include: services to industries, study of explosives, study of pieces belonging to cultural heritage and studies of the distribution of hydrogen. The actual neutron radiography facility is placed in the RA-6 reactor at the Centro Atomico Bariloche. Due to the reactor's nucleus change and the subsequent power raise, it has been necessary to redesign the facility. During the last year the pieces that constitute it had been designed and built. In April 2012 the facility has been mounted. The system employed is of on-line neutron radiographies. The maximum area of study is of 20 cm x 20 cm. The images obtained are registered by a CCD camera, whose maximum resolution is of 2776 x 2074 pixels and 65536 gray levels. In this work the initial steps towards characterization of the facility are presented, these include neutron fluxes and dose rates levels determinations. Also, in order to evaluate the functionality, images of several objects have been taken, as the one shown in Fig. 7. The results obtained reveal the good performance of the facility and its wide potential (author)

  11. A Simple and Inexpensive Collimator for Neutron Radiography

    DEFF Research Database (Denmark)

    Olsen, J.; Mortensen, L.

    1974-01-01

    A neutron beam collimator was constructed by means of plastic drinking “straws”. The properties of the collimator were investigated, and especially the distribution of the neutrons at different distances....

  12. Characterization of film-converter screens systems for neutron radiography; Caracterizacao de sistemas filme-conversor para radiografia com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Leandro Garcia

    2002-07-01

    In general a good quality radiography is that one able to furnish high contrast and sharp edge images. Technically 'high contrast' means high capability to discern material thickness and 'sharp edges', high resolution power. In the present work the optimal conditions to obtain neutron radiography images by using the following film-converter screen systems, Kodak-AA/Gd vaporated; Kodak-AA/Gd metallic; Kodak-AA/LiF; Min-R/GdS{sub 2}O{sub 4}, have been determined. The irradiations were performed in a radiographic facility which was designed and constructed by the neutron radiography working group and is installed at the beamhole 08 of the IEA-R1 nuclear research reactor of the IPEN-CNEN/SP. In order to determine such conditions, the start point was to evaluate the neutron exposure interval for which the optical contrast is maximal and so quantify the sensitivity or capability to discern material thickness, as well as the spatial resolution achieved in the radiographic image, for these systems. The best results have been obtained for the Kodak-AA/Gd vaporated system which is able to discern, for example, 0,024 cm of lucite, with a maximal resolution of 22{mu}m. The radiography images presently obtained in IPEN-CNEN/SP have similar quality when compared to the ones from several other research centers, around the world, whose making use of the same film-converter screens systems. (author)

  13. Neutron radiography, a powerful method to determine time-dependent moisture distributions in concrete

    International Nuclear Information System (INIS)

    Zhang Peng; Wittmann, Folker H.; Zhao Tiejun; Lehmann, Eberhard H.; Vontobel, Peter

    2011-01-01

    Highlights: ► For the first time water movement in cement-based materials could be quantified in a non-destructive way. ► neutron radiography has a sensitivity and a spatial resolution unknown so far. ► Results are essential for prediction of service life. ► Results will contribute to more durable and more ecological construction. - Abstract: Service life of reinforced concrete structures is often limited by penetration of water and compounds dissolved in water into concrete. Concrete can be damaged in this way and corrosion of steel reinforcement can be initiated. There is an urgent need to study water penetration into concrete in order to better understand deterioration mechanisms and to find appropriate ways to improve durability. Neutron radiography provides us with an advanced non-destructive technique with high spatial resolution and extraordinary sensitivity. In this contribution, neutron radiography was successfully applied to study the process of water absorption of two types of concrete with different water–cement ratios, namely 0.4 and 0.6. The influence cracks and of water repellent treatment on water absorption has been studied on mortar specimens. It is possible to visualize migration of water into concrete and other cement-based composites and to quantify the time-dependent moisture distributions as function of time with high spatial resolution by means of neutron radiography. Water penetration depth obtained from neutron radiography is in good agreement with corresponding values obtained from capillary suction tests. Surface impregnation of concrete with silane prevents capillary uptake of water. Even fine cracks are immediately filled with water as soon as the surface gets in contact. Results provide us with a solid basis for a better understanding of deteriorating processes in concrete and other cement-based materials.

  14. The real-time neutron radiography system at Texas A and M University

    International Nuclear Information System (INIS)

    Reuscher, Jon A.

    1990-01-01

    This paper reports on the development and fabrication of a real-time system at Texas A and M University using commercially available and relatively inexpensive components. The real-time neutron radiography system consists of two major components: a camera and image processing equipment. The neutron beam provides a thermal neutron flux of 10 neutrons/cm -sec (cadmium ratio of 4.0) with the TRIGA reactor operating at a power of 1 MW. A remotely operated turntable is used to position the sample in the neutron beam for optimum viewing and ease of changing position. The front surface mirror at 45 deg. to the neutron beam reflects the scintillation image to the lens. The IRO and CCD camera are placed behind shielding out of the neutron. Results using the imaging system for a cadmium plate (0.032 inch thick) with several holes of different diameters are presented. Applications of this neutron radiography system include sensitivity indicators for the spatial resolution of bubbles in water-filled tubes, moisture content of zeolite samples, operating heat pipes and the freezing and thawing of metallic samples

  15. Neutron radiography with sub-15 {mu}m resolution through event centroiding

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, Anton S., E-mail: ast@ssl.berkeley.edu [Space Sciences Laboratory, University of California at Berkeley, Berkeley, CA 94720 (United States); McPhate, Jason B.; Vallerga, John V.; Siegmund, Oswald H.W. [Space Sciences Laboratory, University of California at Berkeley, Berkeley, CA 94720 (United States); Bruce Feller, W. [NOVA Scientific, Inc. 10 Picker Road, Sturbridge, MA 01566 (United States); Lehmann, Eberhard; Kaestner, Anders; Boillat, Pierre; Panzner, Tobias; Filges, Uwe [Spallation Neutron Source Division, Paul Scherrer Institute, CH-5232 Villigen (Switzerland)

    2012-10-01

    Conversion of thermal and cold neutrons into a strong {approx}1 ns electron pulse with an absolute neutron detection efficiency as high as 50-70% makes detectors with {sup 10}B-doped Microchannel Plates (MCPs) very attractive for neutron radiography and microtomography applications. The subsequent signal amplification preserves the location of the event within the MCP pore (typically 6-10 {mu}m in diameter), providing the possibility to perform neutron counting with high spatial resolution. Different event centroiding techniques of the charge landing on a patterned anode enable accurate reconstruction of the neutron position, provided the charge footprints do not overlap within the time required for event processing. The new fast 2 Multiplication-Sign 2 Timepix readout with >1.2 kHz frame rates provides the unique possibility to detect neutrons with sub-15 {mu}m resolution at several MHz/cm{sup 2} counting rates. The results of high resolution neutron radiography experiments presented in this paper, demonstrate the sub-15 {mu}m resolution capability of our detection system. The high degree of collimation and cold spectrum of ICON and BOA beamlines combined with the high spatial resolution and detection efficiency of MCP-Timepix detectors are crucial for high contrast neutron radiography and microtomography with high spatial resolution. The next generation of Timepix electronics with sparsified readout should enable counting rates in excess of 10{sup 7} n/cm{sup 2}/s taking full advantage of high beam intensity of present brightest neutron imaging facilities.

  16. Visualization and measurement of pressurized multiphase flow using neutron radiography of JRR-3M system

    Energy Technology Data Exchange (ETDEWEB)

    Katoh, Yasuo [Yamaguchi Univ. (Japan); Matsubayasi, Masahito

    1998-01-01

    Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in the vessel was controlled. The imaging was done in the following way: A test chamber was provided beside the vessel to receive neutron beams from the JRR-3M system, the intensity of transmitted neutrons was converted to visible light by scintillator and the images were videotaped. The initial objectives of visualizing and measuring bubbles occurring, growing and collapsing and solid particles circulating in the solid-gas two-phase flow have been achieved by means of neutron radiography. (N.H.)

  17. Visualization of boiling two-phase flow in a small diameter tube using neutron radiography

    International Nuclear Information System (INIS)

    Hibiki, Takashi; Mishima, Kaichiro; Yoneda, Kenji; Fujine, Shigenori; Kanda, Keiji; Nishihara, Hideaki

    1991-01-01

    The characteristics of boiling two-phase flow in a small diameter tube are very important for cooling the blanket in a nuclear fusion reactor or a high performance electronic device. For all these subjects, it is necessary to visualize the flow in a tube as a starting point of the study. However, when an optical method cannot be used for the visualization, it is expected that neutron radiography is useful. In this study, the feasibility of visualization of boiling two-phase flow in a small diameter tube was investigated by using various facilities of neutron radiography as the first step. The basic concept of neutron radiography and the block diagram of a neutron television system are shown. The neutron beam attenuated by water in the test section makes a scintillator emit visible light, and produces an image of two-phase flow, which is taken with a TV camera. Thus the image can be observed at real time. Three kinds of the experiments were performed with the facilities of KUR, NSRR and JRR-3. The experimental methods and the results are reported. The images obtained were sufficiently clear. (K.I.)

  18. Inspection of the hydrogen gas pressure with metal shield by cold neutron radiography at CMRR

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hang; Cao, Chao; Huo, Heyong; Wang, Sheng; Wu, Yang; Yin, Wei; Sun, Yong; Liu, Bin; Tang, Bin [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Key Laboratory of Neutron Physics, Chinese Academy of Engineering Physics, Mianyang (China)

    2017-04-11

    The inspection of the process of gas pressure change is important for some applications (e.g. gas tank stockpile or two phase fluid model) which need quantitative and non-touchable measurement. Neutron radiography provides a suitable tool for such investigations with nice resolution. The quantitative cold neutron radiography (CNR) is developed at China Mianyang Research Reactor (CMRR) to measure the hydrogen gas pressure with metal shield. Because of the high sensitivity to hydrogen, even small change of the hydrogen pressure can be inspected by CNR. The dark background and scattering neutron effect are both corrected to promote measurement precision. The results show that CNR can measure the hydrogen gas pressure exactly and the pressure value average relative error between CNR and barometer is almost 1.9%.

  19. Discriminated neutron and X-ray radiography using multi-color scintillation detector

    International Nuclear Information System (INIS)

    Nittoh, Koichi; Takahara, Takeshi; Yoshida, Tadashi; Tamura, Toshiyuki

    1999-01-01

    A new conversion screen Gd 2 O 2 S:Eu is developed, which emits red light on irradiation by thermal neutrons. By applying this in combination with the currently used Gd 2 O 2 S:Tb, a green-light scintillator, in the radiography under a neutron + X-ray coexisting field, we can easily separate the neutron image and the X-ray image by simple color-image processing. This technique enables a non-destructive and detailed inspection of industrial products composed both of light elements (water, plastics, etc.) and heavy elements (metals), widening the horizon of new applications

  20. Discriminated neutron and X-ray radiography using multi-color scintillation detector

    CERN Document Server

    Nittoh, K; Yoshida, T; Tamura, T

    1999-01-01

    A new conversion screen Gd sub 2 O sub 2 S:Eu is developed, which emits red light on irradiation by thermal neutrons. By applying this in combination with the currently used Gd sub 2 O sub 2 S:Tb, a green-light scintillator, in the radiography under a neutron + X-ray coexisting field, we can easily separate the neutron image and the X-ray image by simple color-image processing. This technique enables a non-destructive and detailed inspection of industrial products composed both of light elements (water, plastics, etc.) and heavy elements (metals), widening the horizon of new applications.

  1. Design of neutron beams at the Argonne Continuous Wave Linac (ACWL) for boron neutron capture therapy and neutron radiography

    International Nuclear Information System (INIS)

    Zhou, X.L.; McMichael, G.E.

    1994-01-01

    Neutron beams are designed for capture therapy based on p-Li and p-Sc reactions using the Argonne Continuous Wave Linac (ACWL). The p-Li beam will provide a 2.5 x 10 9 n/cm 2 s epithermal flux with 7 x 10 5 γ/cm 2 s contamination. On a human brain phantom, this beam allows an advantage depth (AD) of 10 cm, an advantage depth dose rate (ADDR) of 78 cGy/min and an advantage ratio (AR) of 3.2. The p-Sc beam offers 5.9 x 10 7 n/cm 2 s and a dose performance of AD = 8 cm and AR = 3.5, suggesting the potential of near-threshold (p,n) reactions such as the p-Li reaction at E p = 1.92 MeV. A thermal radiography beam could also be obtained from ACWL

  2. Numerical simulation for fractional order stationary neutron transport equation using Haar wavelet collocation method

    Energy Technology Data Exchange (ETDEWEB)

    Saha Ray, S., E-mail: santanusaharay@yahoo.com; Patra, A.

    2014-10-15

    Highlights: • A stationary transport equation has been solved using the technique of Haar wavelet collocation method. • This paper intends to provide the great utility of Haar wavelets to nuclear science problem. • In the present paper, two-dimensional Haar wavelets are applied. • The proposed method is mathematically very simple, easy and fast. - Abstract: In this paper the numerical solution for the fractional order stationary neutron transport equation is presented using Haar wavelet Collocation Method (HWCM). Haar wavelet collocation method is efficient and powerful in solving wide class of linear and nonlinear differential equations. This paper intends to provide an application of Haar wavelets to nuclear science problems. This paper describes the application of Haar wavelets for the numerical solution of fractional order stationary neutron transport equation in homogeneous medium with isotropic scattering. The proposed method is mathematically very simple, easy and fast. To demonstrate about the efficiency and applicability of the method, two test problems are discussed.

  3. Employment of the polycarbonates Makrofol-DE and CR-39 for neutron radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2000-01-01

    The track-etch method was employed for Neutron Radiography purposes. The solid state nuclear track detectors Makrofol-DE and CR-39 together with a natural boron converter screen have been used as imaging systems. In order to determine their radiographic characteristics, the imaging systems were irradiated up to neutron exposures around 6x10 10 /cm 2 in a radiography facility installed at the IEA-R1 Nuclear Research Reactor and the detectors developed between 2 and 65 minutes. The main goal of this work was determine the radiography conditions for which the best contrast and resolution are obtained at the image. These conditions are: - Makrofol-DE: neutron exposure between 2x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 6 minutes; CR-39: neutron exposure between 3x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 25 minutes. The present results were compared with those ones determined to other track detectors, and discussed according to the theory of the image formation in solid state nuclear track detectors based on the optical properties of a single track. (author)

  4. Neutron radiography for the characterization of porous structure in degraded building stones

    International Nuclear Information System (INIS)

    Barone, G; Mazzoleni, P; Raneri, S; Crupi, V; Longo, F; Majolino, D; Venuti, V; Teixeira, J

    2014-01-01

    As it is well known, the porous structure of stones can change due to different degradation processes that modify the characteristics of freshly quarried blocks. Their knowledge is fundamental for predicting the behavior of stones and the efficacy of conservative treatments. In this context, neutron radiography is a useful tool not only to visualize the structure of porous materials, but also to evaluate the degree of degradation and surface modifications resulting from weathering processes. Furthermore, since thermal neutrons suffer a strong attenuation by hydrogen, this technique is effective in order to investigate the amount of absorbed water in building materials. In the present work, we report a neutron radiography investigation of limestones cropping out in the South-Eastern Sicily and widely used as building stones in Baroque monuments of the Noto Valley. The analyzed samples have been submitted to cyclic salt crystallization that simulate degradation processes acting in exposed stones of buildings. The obtained results demonstrate the interest of neutron radiography to better understand deterioration processes in limestones and to acquire information useful for restoration projects

  5. Application of fast neutron radiography to three-dimensional visualization of steady two-phase flow in a rod bundle

    CERN Document Server

    Takenaka, N; Fujii, T; Mizubata, M; Yoshii, K

    1999-01-01

    Three-dimensional void fraction distribution of air-water two-phase flow in a 4x4 rod-bundle near a spacer was visualized by fast neutron radiography using a CT method. One-dimensional cross sectional averaged void fraction distribution was also calculated. The behaviors of low void fraction (thick water) two-phase flow in the rod bundle around the spacer were clearly visualized. It was shown that the void fraction distributions were visualized with a quality similar to those by thermal neutron radiography for low void fraction two-phase flow which is difficult to visualize by thermal neutron radiography. It is concluded that the fast neutron radiography is efficiently applicable to two-phase flow studies.

  6. Applications and characteristics of imaging plates as detector in neutron radiography at SINQ

    CERN Document Server

    Kolbe, H; Gunia, W; Körner, S

    1999-01-01

    Imaging plate technique is a commonly accepted method in many fields as in medicine, biology and physics for detection of the distribution of beta- and gamma-radiation or X-rays on large areas. Recently a new type of imaging plate sensitive to neutrons has been developed. The storage layer is doped with gadolinium, which, after absorption of neutrons, produces radiation detectable by the same sensitive crystals used in conventional imaging plates. At the spallation neutron source, SINQ, at the Paul Scherrer Institut (CH) some of the characteristics of the neutron radiography station in combination with the imaging plate technique were investigated. The intensity distribution of the source was measured to check the accuracy for quantification of the image data. Also, the reproducibility of results obtained by this detection system was stated. For a test object, the high selectivity for different neutron absorption is demonstrated at details with low contrast. The obtainable spatial resolution was determined re...

  7. Post-Installation evaluation of the neutron radiography facility of ITU TRIGA Mark-II Reactor

    International Nuclear Information System (INIS)

    Yavuz, H.; Durmayaz, A.

    2008-01-01

    Results of the experiments for determining the characteristics of the previously described neutron radiography facility designed and built in the Istanbul Technical University are presented. The thermal and total neutron fluxes and the gamma exposure rates have been measured inside, at the exit of the neutron beam collimator, and at its surroundings. The ratio of neutron flux to gamma exposure rate at maximum power has been determined. The results have been compared to those measured in the absence of the collimator. The neutron fluxes have been determined by using the foil activation method with gold foils enclosed in cadmium capsules. The gamma exposure rates have been measured by using Li 7 F- CTLD 700 thermoluminescent dosemeters. (authors)

  8. Fuel assembly inspection by three-dimensional neutron radiography

    International Nuclear Information System (INIS)

    Lapinski, N.P.; Reimann, K.J.; Berger, H.

    1979-01-01

    Radiographic inspection of complex objects such as fuel subassemblies often presents problems because superimposition of images at different depths in the object complicates interpretation. One method for obtaining and displaying three-dimensional neutron radiographic images in multiple-film laminagraphy; a series of radiographs generated at different angular orientations are superimposed to provide focussed images of any object plane. In the present work multiple-film neutron laminagraphs were generated using direct and indirect exposure techniques, with neutrons in thermal, epithermal, and fast energy ranges

  9. Recent developments and capabilities in neutron radiography at HEDL

    International Nuclear Information System (INIS)

    Tobin, J.E.; Karnesky, R.A.

    1981-01-01

    Radiographic imaging of irradiated fuels has routinely been qualitative in nature, providing information on the general condition of the internal components of an irradiated fuel pin. Conventional x-ray and neutron radiographic techniques, applicable to irradiated fuels, have not been of high enough resolution to be useful for quantitative image analysis. Recently, however, high resolution neutron radiographic techniques suitable for quantitative image analysis, using precision microdensitometry, have been developed at HEDL. This paper describes the modifications made to a previously developed system to obtain quantitative measurements from high resolution neutron radiographs and evaluates the precision of these measurements

  10. Water calibration measurements for neutron radiography: Application to water content quantification in porous media

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M., E-mail: kangm@ornl.gov [Department of Earth and Planetary Sciences, University of Tennessee, Knoxville, TN (United States); Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Bilheux, H.Z., E-mail: bilheuxhn@ornl.gov [Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Voisin, S. [Computational Sciences and Engineering Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Cheng, C.L.; Perfect, E. [Department of Earth and Planetary Sciences, University of Tennessee, Knoxville, TN (United States); Horita, J. [Department of Geosciences, Texas Tech University, Lubbock, TX (United States); Warren, J.M. [Environmental Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2013-04-21

    Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 0.2 cm when the water calibration cells were positioned close to the face of the detector/scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

  11. Tests of a new CCD-camera based neutron radiography detector system at the reactor stations in Munich and Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, E; Pleinert, H [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Schillinger, B [Technische Univ. Muenchen (Germany); Koerner, S [Atominstitut der Oesterreichischen Universitaeten, Vienna (Austria)

    1997-09-01

    The performance of the new neutron radiography detector designed at PSI with a cooled high sensitive CCD-camera was investigated under real neutronic conditions at three beam ports of two reactor stations. Different converter screens were applied for which the sensitivity and the modulation transfer function (MTF) could be obtained. The results are very encouraging concerning the utilization of this detector system as standard tool at the radiography stations at the spallation source SINQ. (author) 3 figs., 5 refs.

  12. Neutron radiography with 252Cf in forensic science

    International Nuclear Information System (INIS)

    Cason, J.L.

    1972-01-01

    Equipment and methods for neutron radiographic examination of objects in forensic science are described. Examples discussed include booby-trapped ammunition, bomb in a matchbook, gun barrel analysis, narcotics in pen, and chemicals and metals in body tissue

  13. High frame-rate neutron radiography of dynamic events

    International Nuclear Information System (INIS)

    Bossi, R.H.; Robinson, A.H.; Barton, J.P.

    1981-01-01

    A system has been developed to perform neutron radiographic analysis of dynamic events having a duration of several milliseconds. The system has been operated in the range of 2000 to 10,000 frames/second. Synchronization has provided high-speed-motion neutron radiographs for evaluation of the firing cycle of 7.62 mm munition rounds within a steel rifle barrel. The system has also been used to demonstrate the ability to produce neutron radiographic movies of two-phase flow. The equipment uses the Oregon State University TRIGA reactor capable of pulsing to 3000 MW peak power, a neutron beam collimator, a scintillator neutron conversion screen coupled to an image intensifier, and a 16 mm high speed movie camera. The peak neutron flux incident at the object position is approximately 4 x 10 11 n/cm 2 s with a pulse, full width at half maximum, of 9 ms. Special studies have been performed on the scintillator conversion screens and on the effects of statistical limitations on the image quality. Modulation transfer function analysis has been used to assist in the evaluation of the system performance

  14. High frame-rate neutron radiography of dynamic events

    International Nuclear Information System (INIS)

    Bossi, R.H.; Robinson, A.H.; Barton, J.P.

    1983-01-01

    A system has been developed to perform neutron radiographic analysis of dynamic events having a duration of several milliseconds. The system has been operated in the range of 2000 to 10,000 frames/second. Synchronization has provided high-speed-motion neutron radiographs for evaluation of the firing cycle of 7.62 mm munition rounds within a steel rifle barrel. The system has also been used to demonstrate the ability to produce neutron radiographic movies of two phase flow. The equipment uses the Oregon State University TRIGA reactor capable of pulsing to 3000 MW peak power, a neutron beam collimator, a scintillator neutron conversion screen coupled to an image intensifier, and a 16 mm high speed movie camera. The peak neutron flux incident at the object position is approximately 4 x 10 11 n/cm 2 s with a pulse, full width at half maximum, of 9 ms. Special studies have been performed on the scintillator conversion screens and on the effects of statistical limitations on the image quality. Modulation transfer function analysis has been used to assist in the evaluation of the system performance. (Auth.)

  15. Comparison of neutron and high-energy X-ray dual-beam radiography for air cargo inspection

    International Nuclear Information System (INIS)

    Liu, Y.; Sowerby, B.D.; Tickner, J.R.

    2008-01-01

    Dual-beam radiography techniques utilising various combinations of high-energy X-rays and neutrons are attractive for screening bulk cargo for contraband such as narcotics and explosives. Dual-beam radiography is an important enhancement to conventional single-beam X-ray radiography systems in that it provides additional information on the composition of the object being imaged. By comparing the attenuations of transmitted dual high-energy beams, it is possible to build a 2D image, colour coded to indicate material. Only high-energy X-rays, gamma-rays and neutrons have the required penetration to screen cargo containers. This paper reviews recent developments and applications of dual-beam radiography for air cargo inspection. These developments include dual high-energy X-ray techniques as well as fast neutron and gamma-ray (or X-ray) radiography systems. High-energy X-ray systems have the advantage of generally better penetration than neutron systems, depending on the material being interrogated. However, neutron systems have the advantage of much better sensitivity to material composition compared to dual high-energy X-ray techniques. In particular, fast neutron radiography offers the potential to discriminate between various classes of organic material, unlike dual energy X-ray techniques that realistically only offer the ability to discriminate between organic and metal objects

  16. Review of contemporary neutron radiography in Europe and in the U.S.A

    International Nuclear Information System (INIS)

    Heiberg, E.

    1990-01-01

    This paper discusses how neutron radiography (NR) has evolved into a mature NDT/E technology, essentially supplementing information obtainable from that of x-ray radiography (XR). Unique capabilities, however, are the abilities to radiograph radioactive material like nuclear fuel, and to differentiate between isotopes of the same element such as those found in such fuel. Other applications are the detection of inherent hydrogen in corrosion compounds and explosives, and the inspection of the proper location of O-rings in metallic casings. X-ray emulsion film is most commonly employed for the neutron imaging, but track etch offers the superior resolution. Just as for XR, electronic (real time) imaging has great potentially for NR

  17. Inspection of domestic nuclear fuel rods using neutron radiography at the Tehran research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Dastjerdi, Mohammad Hosein Choopan; Khalafi, Hossein; Kasesaz, Yaser [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Movafeghi, Amir

    2016-11-01

    Three unused domestic fuel rods were investigated qualitatively and quantitatively by means of thermal neutron radiography. The neutron radiography tests were performed by the image plate method at Tehran research reactor in order to check the fuel properties. The pellets of these three fuel rods contained three different U-235 enrichments and different sizes that were filled into a zircalloy tube. In the qualitative investigations, the difference in size and enrichment between the pellets and the gaps between them were obviously recognized in the image of the fuel rods. In the quantitative investigations, data of the pellets compositions, their sizes (lengths and diameters) and the gaps between them were extracted from obtained images. It was found that the measured data and the manufacturer's specifications are in good agreement.

  18. Inspection of domestic nuclear fuel rods using neutron radiography at the Tehran research reactor

    International Nuclear Information System (INIS)

    Dastjerdi, Mohammad Hosein Choopan; Khalafi, Hossein; Kasesaz, Yaser; Movafeghi, Amir

    2016-01-01

    Three unused domestic fuel rods were investigated qualitatively and quantitatively by means of thermal neutron radiography. The neutron radiography tests were performed by the image plate method at Tehran research reactor in order to check the fuel properties. The pellets of these three fuel rods contained three different U-235 enrichments and different sizes that were filled into a zircalloy tube. In the qualitative investigations, the difference in size and enrichment between the pellets and the gaps between them were obviously recognized in the image of the fuel rods. In the quantitative investigations, data of the pellets compositions, their sizes (lengths and diameters) and the gaps between them were extracted from obtained images. It was found that the measured data and the manufacturer's specifications are in good agreement.

  19. Combined local current distribution measurements and high resolution neutron radiography of operating direct methanol fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Alexander; Wippermann, Klaus [Forschungszentrum Juelich GmbH (Germany). Inst. of Energy Research, IEF-3: Fuel Cells; Sanders, Tilman [RWTH Aachen (DE). Inst. for Power Electronics and Electrical Drives (ISEA); Arlt, Tobias [Helmholtz Centre Berlin (Germany). Inst. for Applied Materials

    2010-07-01

    Neutron radiography allows the investigation of the local fluid distribution in direct methanol fuel cells (DMFCs) under operating conditions. Spatial resolutions in the order of some tens of micrometers at the full test cell area are achieved. This offers the possibility to study practice-oriented, large stack cells with an active area of several hundred cm{sup 2} as well as specially designed, small test cells with an area of some cm{sup 2}. Combined studies of high resolution neutron radiography and segmented cell measurements are especially valuable, because they enable a correlation of local fluid distribution and local performance [1, 2]. The knowledge of this interdependency is essential to optimise the water management and performance respecting a homogeneous fluid, current and temperature distribution and to achieve high performance and durability of DMFCs. (orig.)

  20. Application of high-frame-rate neutron radiography to steam explosion research

    International Nuclear Information System (INIS)

    Saito, Y.; Mishima, K.; Hibiki, T.; Yamamoto, A.; Sugimoto, J.; Moriyama, K.

    1999-01-01

    To understand the behavior of dispersed molten metal particles dropped into water during the premixing process of steam explosion, experiments were performed by using heated stainless-steel particles simulating dispersed molten metal particles. High-frame-rate neutron radiography was successfully employed for visualization and void fraction measurement. Visualization was conducted by dropping heated stainless-steel particle into heavy water filled in a rectangular tank with the particle diameter (6, 9, and 12 mm) and temperature (600 deg. C, 700 deg. C, 800 deg. C, and 1000 deg. C) as parameters. Steam generation due to direct contact of heated particle and heavy water was successfully visualized by the high-frame-rate neutron radiography at the recording speed of 500 frames/s. From void fraction measurement it was revealed that the amount of generated steam was in proportion to the particle size and temperature. It is suggested that the ambient liquid might be superheated by the particle-liquid contact

  1. Visualization of direct contact heat transfer between water and molten alloy by neutron radiography. 1

    International Nuclear Information System (INIS)

    Nishi, Yoshihisa; Furuya, Masahiro; Kinoshita, Izumi; Takenaka, Nobuyuki; Matsubayashi, Masahito.

    1997-01-01

    Design of an innovative Steam Generator (SG) for Liquid Metal Fast Reactors (LMFRs) using liquid-liquid direct contact heat transfer has been developing. In this concept, the SG shell is filled with a molten alloy, which is heated by primary sodium. Water is fed into the high-temperature, molten alloy, and evaporates by direct contact heating. In order to obtain the fundamental information needed to discuss the heat transfer mechanisms of direct contact between the water and molten alloy, this phenomenon was observed by neutron radiography. JRR-3M thermal neutron radiography at the Japan Atomic Energy Research Institute was used. This paper deals with the results of visualization of direct contact heat exchange in the molten alloy. (author)

  2. Non-destructive analysis of rape plant pod by neutron radiography

    International Nuclear Information System (INIS)

    Makino-Nakanishi, Tomoko; Inanaga, Shinobu; Kobayashi, Hisao.

    1991-01-01

    Since the ripening process of the rape plant pod has not been studied well, non-destructive analysis of the pod has been carried out by neutron radiography. From the water distribution in the pod, the formation of pod parenchyma as well as vascular system were clearly observed. During the ripening process of the pod water content and weight of the seed were measured. It was found that at the early stage of the ripening process the water content of the seed became maximum and began to decrease, whereas the weight of each seed was gradually increased throughout the ripening process. Neutron radiography, which shows the water content of the pod, will give the clue to the decrease of the water content of the seed from the middle of the ripening process. (author)

  3. The minireactor Mirene for neutron-radiography: performances and applications

    International Nuclear Information System (INIS)

    Houelle, M.; Gerberon, J.M.

    1981-05-01

    The MIRENE neutron radiograhy mini-reactor is described. The core contains only one kilogram of enriched uranium in solution form. It works by pulsed operation. The neutron bursts produced are collimated into two beams which pass through the concrete protection around the reactor block. The performance of the reactor and the results achieved since it went into service in 1977 are described. These concern various fields. In the nuclear field: examination of fast neutron reactor fissile pins, monitoring of neutron absorbing screens employed to guarantee the safety-criticality of the transport and storage of the nuclear fuel cycle, observation of irradiated oxide fuel pellets in order to determine the fuel state equation of the fast neutron system, examination of UO 2 and water mixtures for criticality experiments. In the industrial field, Mirene has a vast field of application. Two examples are given: monitoring of electric insulation sealing, visualization of the bonding of two high density metal parts. Finally an original application in agronomy has given very good results: this concerns the on-site follow-up of the root growth of maize plants [fr

  4. Analysis of hydrogen content and distribution in hydrogen storage alloys using neutron radiography

    International Nuclear Information System (INIS)

    Sakaguchi, Hiroki; Hatakeyama, Keisuke; Satake, Yuichi; Esaka, Takao; Fujine, Shigenori; Yoneda, Kenji; Kanda, Keiji

    2000-01-01

    Small amounts of hydrogen in hydrogen storage alloys, such as Mg 2 Ni, were detected using neutron radiography (NRG). Hydrogen concentrations in a hydrogenated solid solution were determined by this technique. Furthermore, we were able to obtain NRG images for an initial stage of hydrogen absorption in the hydrogen storage alloys. NRG would be a new measurement method to clarify the behavior of hydrogen in hydrogen storage alloys. (author)

  5. Scheme for radiography/tomography with a low-brilliance neutron source at the CPHS

    International Nuclear Information System (INIS)

    Huang Zhifeng; Xiao Yongshun; Zhang Ran; Li Yuanji; Han Xiaoxue; Shao Beibei; Wang Xuewu; Wei Jie; Loong, C.-K.

    2011-01-01

    A cold neutron radiography/tomography instrument was designed and will soon undergo construction at the Compact Pulsed Hadron Source (CPHS) of Tsinghua University, China. In this paper, we report the physical design of the instrument and propose a scheme to implement several techniques at a later phase to enhance the utilization of the flux on larger samples. This includes code-aperture, grating-based imaging, prompt gamma-ray analysis and 3D emission CT.

  6. Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography

    International Nuclear Information System (INIS)

    Carlisle, B.S.; Johns, R.C.; Hassan, Y.A.

    2004-01-01

    A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

  7. Research on non-destructive testing (NDT) aerospace igniter fuse with neutron radiography (NR)

    International Nuclear Information System (INIS)

    Mo Dawei; Liu Yisi; Cai Qingsheng; Chen Boxian

    1995-01-01

    The research works, facilities and results of NDT aerospace igniter fuse with neutron radiography at Tsinghua University swimming-pool reactor are introduced. The image quality (NR) of ASTM E545-85 I level was approached. The NR experimental research of the typical and possible defects was performed. The theoretical analysis was performed too. The feasibility of NDT aerospace igniter fuse with NR was proved experimentally

  8. Using MCNP-4C code for design of the thermal neutron beam for neutron radiography at the MNSR

    International Nuclear Information System (INIS)

    Shaaban, I.

    2009-11-01

    Studies were carried out for determination of the parameters of a thermal neutron beam at the MNSR reactor (MNSR-30 kW) for neutron radiography in the vertical beam port by using the MCNP-4C (Monte Carlo Neutron - Photon transport). Thermal, epithermal and fast neutron energy ranges were selected as 10 keV respectively. To produce a good neutron beam in terms of intensity and quality, several materials Lead (Pb), Bismuth (Bi), Borated polyethelyene and Alumina Oxide (Al 2 O 3 ) were used as neutron and photon filters. Based on the current design, the L/D of the facility ranges between 125, 110 and 90. The thermal neutron flux at the beam exit is 1.436x10 5 n/cm2 .s ,1.843x10 5 n/cm2 .s and 2.845x10 5 n/cm2 .s respectively, middots with a Cd-ratio of ∼ 2.829, 2.766, 3.191 for the L/D = 125, 110, 90 respectively. The estimated values for gamma doses are 6.705x10 -2 Rem/h and 1.275x10 -1 Rem/h and 2.678x10 -1 Rem/ h with bismuth. The divergent angle of the collimator is 1.348 degree - 2.021 degree. Such neutron beams, if built into the Syrian MNSR reactor, could support the application of NRG in Syria. (author)

  9. Visualization study of molten metal-water interaction by using neutron radiography

    International Nuclear Information System (INIS)

    Mishima, K.; Hibiki, T.; Saito, Y.

    1999-01-01

    The purpose of this study is to visualize the behavior of molten metal dropped into water during the premixing process by means of neutron radiography which makes use of the difference in the attenuation characteristics of materials. For this purpose, a high-sensitive, high-frame-rate imaging system using neutron radiography was constructed and was applied to visualization of the behavior of molten metal dropped into water. The test rig consisted of a furnace and a test section. The furnace could heat the molten metal up to 650 C. The test section was a rectangular tank made of aluminum alloy. The tank was filled with heavy water and molten Wood's metal was dropped into heavy water. Visualization study was carried out with use of the high-frame-rate neutron radiography to see the breakup of molten metal jet or lump dropped into heavy water pool. In the images obtained, water, steam or air bubbles, molten metal jets or droplets, cloud of small particles of molten metal after atomization could be distinguished. The debris of Wood's metal was collected after the experiment, and the relation between the break-up behavior and the size and the shape of the debris particles was investigated. (orig.)

  10. Development of two-dimensional velocity field measurement using particle tracking velocimetry on neutron radiography

    International Nuclear Information System (INIS)

    Saito, Y.; Mishima, K.; Suzuki, T.; Matsubayashi, M.

    2003-01-01

    The structures of liquid metal two-phase flow are investigated for analyzing the core meltdown accident of fast reactor. The experiments of high-density ratio two-phase flow for lead-bismuth molten metal and nitrogen gases are conducted to understand in detail. The liquid phase velocity distributions of lead-bismuth molten metal are measured by neutron radiography using Au-Cd tracer particles. The liquid phase velocity distributions are obtained usually by using particle image velocimetry (PIV) on the neutron radiography. The PIV, however is difficult to get the velocity vector distribution quantitatively. An image of neutron radiography is divided into two images of the bubbles and the tracer particles each in particle tracking velocimetry (PTV), which distinguishes tracer contents in the bubble from them in the liquid phase. The locations of tracer particles in the liquid phase are possible to determine by particle mask correlation method, in which the bubble images are separated from the tracer images by Σ-scaling method. The particle tracking velocimetry give a full detail of the velocity vector distributions of the liquid phase in two-phase flow, in comparison with the PIV method. (M. Suetake)

  11. Visualization and measurement of thermo-fluid phenomena by using neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mishima, Kaichiro [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.

    1998-03-01

    Recently, neutron radiography is rapidly expanding its application to various fields incollaboration with the development of electronic imaging techniques. Particularly, in the field of thermal and fluid engineering, it has drawn much attention as an innovative and non-intrusive method for fluid-visualization and measurement using neutron beam as a probe. In this paper, some examples of applications are introduced on the high frame-rate imaging, quantification method (especially, determination of void fraction), and multidimensional measurement which are much interested in fluid measurement in relation to light water reactor safety and thermohydraulics. (author)

  12. Visualization of in vitro evaluation of restored teeth with synthetic resins by neutron radiography

    International Nuclear Information System (INIS)

    Barbosa, Andre Luis N.; Crispim, Verginia R.

    2013-01-01

    The goal of the present study was to evaluate whether the technique of neutron radiography can provide information on strength and adherence in dental restoration with synthetic polymeric materials, particularly as a tool for the analysis of micro leakage and voids. Thus, tooth samples were drilled, producing cavities with similar dimensions in each tooth, and then carefully filled with eight types of resins that are the most commonly used by dentists. After exposing the tooth samples to a neutron beam, their radiographic images were analyzed. This technique gave good results showing that all the tooth samples were suitably restored. (author)

  13. Visualization and measurement of thermo-fluid phenomena by using neutron radiography

    International Nuclear Information System (INIS)

    Mishima, Kaichiro

    1998-01-01

    Recently, neutron radiography is rapidly expanding its application to various fields incollaboration with the development of electronic imaging techniques. Particularly, in the field of thermal and fluid engineering, it has drawn much attention as an innovative and non-intrusive method for fluid-visualization and measurement using neutron beam as a probe. In this paper, some examples of applications are introduced on the high frame-rate imaging, quantification method (especially, determination of void fraction), and multidimensional measurement which are much interested in fluid measurement in relation to light water reactor safety and thermohydraulics. (author)

  14. Digital image processing for real-time neutron radiography and its applications

    International Nuclear Information System (INIS)

    Fujine, Shigenori

    1989-01-01

    The present paper describes several digital image processing approaches for the real-time neutron radiography (neutron television-NTV), such as image integration, adaptive smoothing and image enhancement, which have beneficial effects on image improvements, and also describes how to use these techniques for applications. Details invisible in direct images of NTV are able to be revealed by digital image processing, such as reversed image, gray level correction, gray scale transformation, contoured image, subtraction technique, pseudo color display and so on. For real-time application a contouring operation and an averaging approach can also be utilized effectively. (author)

  15. Cavitation phenomena in a fuel injection nozzle of a diesel engine by neutron radiography

    International Nuclear Information System (INIS)

    Takenaka, N.; Kawabata, Y.; Miyata, D.; Kawabata, Y.; Sim, C. M.; Lim, I. C.

    2005-01-01

    Visualization of cavitation phenomena in a Diesel engine fuel injection nozzle was carried out by using neutron radiography system in Research Reactor Institute in Kyoto University and HANARO in Korea Atomic Energy Research Institute. A neutron chopper was synchronized to the engine rotation for high shutter speed exposures. A multi exposure method was applied to obtain a clear image as an ensemble average of the synchronized images. Some images were successfully obtained and suggested new understanding of the cavitation phenomena in a Diesel engine fuel injection nozzle

  16. Analysis of boron utilization in sample preparation for microorganisms detection by neutron radiography technique

    International Nuclear Information System (INIS)

    Wacha, Reinaldo; Crispim, Verginia R.

    2000-01-01

    The neutron radiography technique applied to the microorganisms detection is the study of a new and faster alternative for diagnosis of infectious means. This work presents the parameters and the effects involved in the use of the boron as a conversion agent, that convert neutrons in a particles, capable ones of generating latent tracks in a solid state nuclear tracks detector, CR-39. The collected samples are doped with the boron by the incubation method, propitiating an interaction microorganisms/boron, that will guarantee the identification of the images of those microorganisms, through your morphology. (author)

  17. Feasibility study of the underwater neutron radiography facility using the University of Utah 100 kW TRIGA (UUTR) reactor

    International Nuclear Information System (INIS)

    Choe, D.; Xiao, S.; Jevremovic, T.; Yang, X.

    2010-01-01

    The University of Utah 100 kW TRIGA (UUTR) reactor provides usable neutron yields for neutron radiography. Currently, UUTR reactor has three irradiators (Central, Pneumatic, and Thermal irradiators) and one Fast neutron Irradiation Facility (FNIF). These irradiators are very small so they are not suitable for neutron radiography. UUTR has three beam ports but they are not available due to the structure of the core. All sides of the core are occupied by FNIF, Thermal Irradiator, and three ion chambers. The only available position for underwater vertical beam port is on the top of the FNIF. There are two factors necessary to fulfill to be able to realize vertical underwater beam port: noninterruption to other facilities and radiation shielding. Designing the vertical beam port as movable ensures good access to the core and pool, while still providing a good neutron radiography environment. Keeping the top of the beam port below the surface of the pool the water represents biological shield. Neutron radiographs, with a simple setup of efficient neutron converters and digital camera systems, can produce acceptable resolution with an exposure time as short as a few minutes. It is important to validate the design with calculations before constructing the beam port. The design of the beam port is modeled using the MCNP5 transport code. A minimum of 10 5 neutrons/cm 2 -sec thermal neutron flux is required for high resolution neutron radiography. Currently, the UUTRIGA is in the process of upgrading its power from 100 kW to 250 kW. Upon the completion of the upgrading, the maximum neutron flux in the core will be ∼7x10 12 neutrons/cm 2 -sec. This paper discusses a modeling and evaluation of capability for a neutron radiography facility. (author)

  18. Nondestructive testing: Neutron radiography and neutron activation. (Latest citations from the INSPEC: Information services for the physics and engineering communities database). Published Search

    International Nuclear Information System (INIS)

    1993-08-01

    The bibliography contains citations concerning the technology of neutron radiography and neutron activation for nondestructive testing of materials. The development and evaluation of neutron activation analysis and neutron diffraction examination of liquids and solids are presented. Citations also discuss nondestructive assay, verification, evaluation, and multielement analysis of biomedical, environmental, industrial, and geological materials. Nondestructive identification of chemical agents, explosives, weapons, and drugs in sealed containers are explored. (Contains a minimum of 83 citations and includes a subject term index and title list.)

  19. Radiography and partial tomography of wood with thermal neutrons

    Science.gov (United States)

    Osterloh, K.; Fratzscher, D.; Schwabe, A.; Schillinger, B.; Zscherpel, U.; Ewert, U.

    2011-09-01

    The effective high neutron scattering absorption coefficient of hydrogen (48.5 cm 2/g) due to the scattering allows neutrons to reveal hydrocarbon structures with more contrast than X-rays, but at the same time limits the sample size and thickness that can be investigated. Many planar shaped objects, particularly wood samples, are sufficiently thin to allow thermal neutrons to transmit through the sample in a direction perpendicular to the planar face but not in a parallel direction, due to increased thickness. Often, this is an obstacle that prevents some tomographic reconstruction algorithms from obtaining desired results because of inadequate information or presence of distracting artifacts due to missing projections. This can be true for samples such as the distribution of glue in glulam (boards of wooden layers glued together), or the course of partially visible annual rings in trees where the features of interest are parallel to the planar surface of the sample. However, it should be possible to study these features by rotating the specimen within a limited angular range. In principle, this approach has been shown previously in a study with fast neutrons [2]. A study of this kind was performed at the Antares facility of FRM II in Garching with a 2.6×10 7/cm 2 s thermal neutron beam. The limit of penetration was determined for a wooden step wedge carved from a 2 cm×4 cm block of wood in comparison to other materials such as heavy metals and Lucite as specimens rich in hydrogen. The depth of the steps was 1 cm, the height 0.5 cm. The annual ring structures were clearly detectable up to 2 cm thickness. Wooden specimens, i.e. shivers, from a sunken old ship have been subjected to tomography. Not visible from the outside, clear radial structures have been found that are typical for certain kinds of wood. This insight was impaired in a case where the specimen had been soaked with ethylene glycol. In another large sample study, a planar board made of glulam has

  20. Radiography and partial tomography of wood with thermal neutrons

    International Nuclear Information System (INIS)

    Osterloh, K.; Fratzscher, D.; Schwabe, A.; Schillinger, B.; Zscherpel, U.; Ewert, U.

    2011-01-01

    The effective high neutron scattering absorption coefficient of hydrogen (48.5 cm 2 /g) due to the scattering allows neutrons to reveal hydrocarbon structures with more contrast than X-rays, but at the same time limits the sample size and thickness that can be investigated. Many planar shaped objects, particularly wood samples, are sufficiently thin to allow thermal neutrons to transmit through the sample in a direction perpendicular to the planar face but not in a parallel direction, due to increased thickness. Often, this is an obstacle that prevents some tomographic reconstruction algorithms from obtaining desired results because of inadequate information or presence of distracting artifacts due to missing projections. This can be true for samples such as the distribution of glue in glulam (boards of wooden layers glued together), or the course of partially visible annual rings in trees where the features of interest are parallel to the planar surface of the sample. However, it should be possible to study these features by rotating the specimen within a limited angular range. In principle, this approach has been shown previously in a study with fast neutrons . A study of this kind was performed at the Antares facility of FRM II in Garching with a 2.6x10 7 /cm 2 s thermal neutron beam. The limit of penetration was determined for a wooden step wedge carved from a 2 cmx4 cm block of wood in comparison to other materials such as heavy metals and Lucite as specimens rich in hydrogen. The depth of the steps was 1 cm, the height 0.5 cm. The annual ring structures were clearly detectable up to 2 cm thickness. Wooden specimens, i.e. shivers, from a sunken old ship have been subjected to tomography. Not visible from the outside, clear radial structures have been found that are typical for certain kinds of wood. This insight was impaired in a case where the specimen had been soaked with ethylene glycol. In another large sample study, a planar board made of glulam has been

  1. HANARO Neutron Radiography Facility and Fuel Cell Research

    International Nuclear Information System (INIS)

    Kim, Taejoo

    2013-01-01

    Fuel cell which generates electric energy from hydrogen and oxygen is one of noticed renewable energy system because this has high efficiency and free from CO 2 . Especially, PEMFC (Polymer Electrolyte Membrane Fuel Cell) is focused by automotive companies because PEMFC, which has high power rate per volume and low operating temperature (60∼80), is suited due to the compact design and short start-up time. The water management is one of the most critical issues for fuel cell commercialization. In order to make a proper scheme for water management, thein formation of water distribution and behavior is very important. Neutron imaging is the best method to visualize the water at fuel cell and has been applied worldwide with qualitative and quantitative results. Because the NRF has large beam size (350Χ450mm 2 ) and relatively high neutron flux (2Χ107 n/cm 2 sec), it is suitable for large scale fuel cell research. Neutron imaging technique was used to investigate the water distribution and behavior in PEMFC under different operating conditions. The NRF has contributed the improvement of fuel cell performance and is one of the best choices for fuel cell study

  2. Quantitative determination of absorbed hydrogen in oxidised zircaloy by means of neutron radiography

    International Nuclear Information System (INIS)

    Grosse, M.; Lehmann, E.; Vontobel, P.; Steinbrueck, M.

    2006-01-01

    Hydrogen absorbed in steam-oxidised zircaloy can be determined quantitatively by means of neutron radiography. Correlation parameters between the total cross section and hydrogen content as well as oxide layer thickness were determined quantitatively. At H/Zr atomic ratios lower than 1.0, linear correlations between the hydrogen content and total cross section exist. The total cross section of Zr is lower and the effect of the hydrogen is higher in radiography measurements with a cold neutron spectrum than with a thermal spectrum. A Be filter reduces the effects of lower wavelength and epithermal neutrons and extends the linear correlations to higher H/Zr atomic ratios. Due to the better possibilities of background corrections, the neutron image should be detected by a CCD camera for a proper quantitative analysis with a medium spatial resolution of about 0.1 mm. A higher spatial resolution, but larger uncertainties in the quantitative hydrogen determination are achieved by measurements with imaging plates. The effect of oxygen layers on the total cross section is much smaller than the effect of hydrogen. The total cross section measured depends linearly on the oxide layer thickness

  3. Real-time neutron radiography at the Iea-R1 m nuclear research reactor

    International Nuclear Information System (INIS)

    Menezes, M.O. de; Pugliesi, R.; Pereira, M.A.S.; Andrade, M.L.G.

    2003-01-01

    A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average value is 0:70 +- 0:09 mm. (author)

  4. Stereographic images acquired with gamma rays and thermal neutron radiography

    International Nuclear Information System (INIS)

    Souza, Maria Ines Silvani; Almeida, Gevaldo L. de; Furieri, Rosanne C.; Lopes, Ricardo T.

    2011-01-01

    Full text: The inner structure of an object, which should not be submitted to an invasive assay, can only be perceived by using a suitable technique in order to render it transparent. A widely employed technique for this purpose involves the using of a radiation capable to pass through the object, collecting the transmitted radiation by a proper device, which furnishes a radiographic attenuation map of the object. This map, however, does not display the spatial distribution of the inner components of the object, but a convoluted view for each specific attitude of the object with regard to the set beam-detector. A 3D tomographic approach would show that distribution but it would demand a large number of projections requiring special equipment and software, not always available or affordable. In some circumstances however, a 3D tomography can be replaced by a stereographic view of the object under inspection, as done in this work, where instead of tens of radiographic projections, only two of them taken at suitable object attitudes are employed. Once acquired, these projections are properly processed and observed through a red and green eyeglass. For monochromatic images, this methodology requires the transformation of the black and white radiographs into red and white and green and white ones, which are afterwards merged to yield a single image. All the process is carried out with the software Image J . In this work, the Argonauta reactor at the Instituto de Engenharia Nuclear in Rio de Janeiro has been used as a source of thermal neutrons to acquire the neutron radiographic images, as well as to produce 198 Au sources employed in the acquisition of gamma-ray radiographic ones. X-ray or neutron-sensitive imaging plates have been used as detector, which after exposure were developed by a reader using a 0.5μm-diameter laser beam. (author)

  5. Scientific Design of the New Neutron Radiography Facility (SANRAD) at SAFARI-1 for South Africa

    Science.gov (United States)

    de Beer, F. C.; Gruenauer, F.; Radebe, J. M.; Modise, T.; Schillinger, B.

    The final scientific design for an upgraded neutron radiography/tomography facility at beam port no.2 of the SAFARI-1 nuclear research reactor has been performed through expert advice from Physics Consulting, FRMII in Germany and IPEN, Brazil. A need to upgrade the facility became apparent due to the identification of various deficiencies of the current SANRAD facility during an IAEA-sponsored expert mission of international scientists to Necsa, South Africa. A lack of adequate shielding that results in high neutron background on the beam port floor, a mismatch in the collimator aperture to the core that results in a high gradient in neutron flux on the imaging plane and due to a relative low L/D the quality of the radiographs are poor, are a number of deficiencies to name a few.The new design, based on results of Monte Carlo (MCNP-X) simulations of neutron- and gamma transport from the reactor core and through the new facility, is being outlined. The scientific design philosophy, neutron optics and imaging capabilities that include the utilization of fission neutrons, thermal neutrons, and gamma-rays emerging from the core of SAFARI-1 are discussed.

  6. Neutron radiography in the IEA-R1 reactor

    International Nuclear Information System (INIS)

    Pugliesi, R.; Moraes, A.P.V. de; Yamazaki, I.M.; Freitas Acosta, C. de.

    1988-08-01

    Neutronradiography of several materials have been obtained at the IEA-R1 Nuclear Research Reactor (IPEN-CNEN/SP), by means of two conversion techniques: a) (n, α) at the beam-hole n 0 3 where a collimated thermal neutron beam, exposure area 4 cm x 8cm and flux at the sample 10 5 n/s cm 2 is obtained. The film used was the CN-85 cellulose nitrate coated with lithium tetraborate (conversor). The time irradiation of the film was 15 minutes and in following was eteched during 30 minutes in a NaOH(10%) aqueous solution at a constant temperature of 60 0 C.; b) (n,γ) by using an experimental arrangement installed in the botton of the pool of the reactor. The flux of the collimated neutron beam is 10 5 n/s/cm 2 at the sample and the conversion is made by means of a dysprozium sheet. The film used was Kodak T-5. The irradiation and the transfering time was 2 hours and 20 hours respectively. (author) [pt

  7. Characterization and optimization of the R A-6 s on-line neutron radiography facility

    International Nuclear Information System (INIS)

    Mezio Guanes, Federico Andres

    2007-01-01

    With the objective of characterizing and optimizing the radiation-field filters behavior in the beam of the R A-6 on-line Neutron Radiography facility, some improvements have been done to the facility devices.We studied the camera sensibility, the best camera acquisition software configuration, the best depth of field, we increased the system tuning efficiency.We also studied the linearity of the facility vs the reactor core neutron fluence and finally we constructed a device that ensure the repeatability of the measurements.The main parameters chosen to represent the best radiation-field set-up are the thermal neutron flux and dose in the position of the camera.Finally, a camera shield optimization haven been done in function of its position [es

  8. Assessment of Electromagnetic Stirrer Agitated Liquid Metal Flows by Dynamic Neutron Radiography

    Science.gov (United States)

    Ščepanskis, Mihails; Sarma, Mārtiņš; Vontobel, Peter; Trtik, Pavel; Thomsen, Knud; Jakovičs, Andris; Beinerts, Toms

    2017-04-01

    This paper presents qualitative and quantitative characterization of two-phase liquid metal flows agitated by the stirrer on rotating permanent magnets. The stirrer was designed to fulfill various eddy flows, which may have different rates of solid particle entrapment from the liquid surface and their homogenization. The flow was characterized by visualization of the tailored tracer particles by means of dynamic neutron radiography, an experimental method well suited for liquid metal flows due to low opacity of some metals for neutrons. The rather high temporal resolution of the image acquisition (32 Hz image acquisition rate) allows for the quantitative investigation of the flows up to 30 cm/s using neutron particle image velocimetry. In situ visualization of the two-phase liquid metal flow is also demonstrated.

  9. Study of a transportable neutron radiography system; Estudo de um sistema neutrongrafico transportavel

    Energy Technology Data Exchange (ETDEWEB)

    Souza, S N.A. de

    1991-05-01

    This work presents a study a transportable neutron radiography system for a 185 GBq {sup 241} Am-Be ({alpha}, {eta}) source with a neutron yield roughly 1,25 x 10{sup 7} n/s. Studies about moderation, collimation and shielding are showed. In these studies, a calculation using Transport Theory was carried out by means of transport codes ANISN and DOT (3.5). Objectives were: to obtain a maximum and more homogeneous thermal neutron flux in the collimator outlet to the image plain, and an adequate radiation shielding to attend radiological protection rules. With the presented collimator, it was possible to obtain for the thermal neutron flux, at the collimator outlet and next to the image plain, a L/D ratio of 14, for neutron fluxes up to 4,09 x 10{sup 2} n.cm{sup -2}.s{sup -1}. Considering the low intensity of the source, it is a good value. Studies have also been carried out for L/D ratios of 22 and 30, giving thermal neutron fluxes at the image plain of 1,27 x 10{sup 2} n.cm{sup -2}.s{sup -1} and 2,65 x 10{sup 2} n.cm{sup -2}.s{sup -1}, respectively. (author). 30 refs, 39 figs, 9 tabs.

  10. Development of measurement method of void fraction distribution on subcooled flow boiling using neutron radiography

    International Nuclear Information System (INIS)

    Kureta, Masatoshi; Matsubayashi, Masahito; Akimoto, Hajime

    1999-03-01

    In relation to the development of a solid target of high intensity neutron source, plasma-facing components of fusion reactor and so forth, it is indispensable to estimate the void fraction for high-heat-load subcooled flow boiling of water. Since the existing prediction method of void fraction is based on the database for tubes, it is necessary to investigate extendibility of the existing prediction method to narrow-gap rectangular channels that is used in the high-heat-load devices. However, measurement method of void fraction in the narrow-gap rectangular channel has not been established yet because of the difficulty of measurement. The objectives of this investigation are development of a new system for bubble visualization and void fraction measurement on subcooled flow boiling in narrow-gap rectangular channels using the neutron radiography, and establishment of void fraction database by using this measurement system. This report describes the void fraction measurement method by the neutron radiography technique, and summarizes the measured void fraction data in one-side heated narrow-gap rectangular channels at subcooled boiling condition. (author)

  11. Plasma focus sources: Supplement to the neutron resonance radiography workshop proceedings

    International Nuclear Information System (INIS)

    Nardi, V.; Brzosko, J.

    1989-01-01

    Since their discovery, plasma focus discharges have been recognized as very intense pulsed sources of deuterium-deuterium (D-D) or deuterium-tritium (D-T) fusion-reaction neutrons, with outstanding capabilities. Specifically, the total neutron emission/shot, YN, and the rate of neutron emission, Y/sub n/, of an optimized plasma focus (PF) are higher than the corresponding quantities observed in any other type of pinched discharge at the same level of powering energy W 0 . Recent developments have led to the concept and experimental demonstration of an Advanced Plasma Focus System (APF) that consists of a Mather-geometry plasma focus in which field distortion elements (FDEs) are inserted in the inter-electrode gap for increasing the neutron yield/shot, Y/sub n/. The FDE-induced redistribution of the plasma current increases Y/sub n/ by a factor ≅5-10 above the value obtained without FDEs under otherwise identical conditions of operation of the plasma focus. For example, an APF that is fed by a fast capacitor bank with an energy, W 0 = 6kJ, and voltage, V 0 = 16.5 kV provides Y/sub n/ /congruent/ 4 /times/ 10 9 D-D neutrons/shot (pure D 2 filling) and Y/sub n/ = 4 /times/ 10 11 D-T neutrons/shot (filling is 50% deuterium and 50% tritium). The FDE-induced increase of Y/sub n/ for fixed values of (W 0 , V 0 ), the observed scaling law Y/sub n/ /proportional to/ W 0 2 for optimized plasma focus systems, and our experience with neutron scattering in bulk objects lead us to the conclusion that we can use an APF as a source of high-intensity neutron pulses (10 14 n/pulse) in the field off neutron radiography (surface and bulk) with a nanosecond or millisecond time resolution

  12. Radiography studies with gamma rays produced by 14-MeV fusion neutrons

    International Nuclear Information System (INIS)

    Smith, D.L.; Ikeda, Yujiro; Uno, Yoshitomo

    1996-01-01

    Oxygen contained in pure water has been activated via the 16 O(n, p) 16 N reaction using 14-MeV neutrons produced at a neutron generator with the 3 H(d,n) 4 He source. Photons of 6.129 and 7.115 MeV, generated by the decay of 7.13-second 16 N, were then used to demonstrate the feasibility of employing highly penetrating, nearly monoenergetic gamma rays for radiography studies of thick, dense objects composed of elements with medium to relatively high atomic numbers. A simple radiography apparatus was constructed by circulating water continuously between a position near the target of the neutron generator and a remote location where photon transmission measurements were conducted. A sodium iodide scintillator was employed to detect the photons. Pulses equivalent to photon energies smaller than 2.506 MeV (corresponding to the cascade sum of 1.333- and 1.173-MeV gamma rays from the decay of 5.271-year 60 Co) were rejected by the electronics settings in order to reduce background and improve the signal-to-noise (S/N) ratio. Respectable S/N ratios on the order of 20-to-1 were achieved with this setup. Most of the background (N) could be attributed to ambient environmental radiation and cosmic-ray interactions with the lead shielding and detector. Four representative objects were examined by photon radiography in this study. This demonstrated how such - interesting features as hidden holes and discontinuities in atomic number could be easily identified from observed variations in the intensity of transmitted photons. Some advantages of this technique are described, and potential applications are suggested for a future scenario where fusion reactors are used to generate electric power and very intense sources of high-energy photons from 16 N decay are continuously available as a byproduct of the reactor cooling process

  13. Fast neutron radiography scanner for the detection of contraband in air cargo containers

    International Nuclear Information System (INIS)

    Eberhardt, J.E.; Rainey, S.; Stevens, R.J.; Sowerby, B.D.; Tickner, J.R.

    2005-01-01

    There is a growing need to rapidly scan bulk air cargo for contraband such as illicit drugs and explosives. The Commonwealth Science and Industrial Research Organisation (CSIRO) have been working with Australian Customs Service to develop a scanner capable of directly scanning airfreight containers in 1-2 minutes without unpacking. The scanner combines fast neutron and gamma-ray radiography to provide high-resolution images that include information on material composition. A full-scale prototype scanner has been successfully tested in the laboratory and a commercial-scale scanner is due to be installed at Brisbane airport in 2005

  14. Fast neutron radiography scanner for the detection of contraband in air cargo containers

    Energy Technology Data Exchange (ETDEWEB)

    Eberhardt, J.E. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia); Rainey, S. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia); Stevens, R.J. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia); Sowerby, B.D. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia)]. E-mail: brian.sowerby@csiro.au; Tickner, J.R. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia)

    2005-08-01

    There is a growing need to rapidly scan bulk air cargo for contraband such as illicit drugs and explosives. The Commonwealth Science and Industrial Research Organisation (CSIRO) have been working with Australian Customs Service to develop a scanner capable of directly scanning airfreight containers in 1-2 minutes without unpacking. The scanner combines fast neutron and gamma-ray radiography to provide high-resolution images that include information on material composition. A full-scale prototype scanner has been successfully tested in the laboratory and a commercial-scale scanner is due to be installed at Brisbane airport in 2005.

  15. MTF analysis of the near-real time neutron radiography facility at MURR

    International Nuclear Information System (INIS)

    Lindsay, J.T.; Alger, D.M.; Bull, S.R.; Miller, W.H.

    1983-01-01

    Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.)

  16. The application of neutron radiography to the measurement of the water-permeability of concrete

    International Nuclear Information System (INIS)

    Mo, Dawei; Zhang, Chaozong; Guo, Zhi-Ping; Liu, Yisi; An, Fulin; Mio, Qitian; Wang, Zhimin; Lian, Huizhen.

    1988-01-01

    The water-permeability of concrete is significant for dam, offshore platform and under-water basement of brindge etc. The traditional measuring method of permeability is the fixed pressure of water method in which the water-permeating process in a concreteblock cannot be measured continuously. Owing to the obvious difference of hydrogen content in the permeated regions of samples and the regions which have not been permeated. A combination of the neutron radiography and traditional method has been used to study continuously the whole process of water permeating. The combined method overcomes some shortages of the traditional methods and helps to gain more informations. (author)

  17. Study on the characterization of the neutron radiography facility in HANARO for two-phase flow research

    International Nuclear Information System (INIS)

    Lim, I. C.; Seo, C. G.; Jeong, J. H.; Lee, B. H.; Choi, Y. S.

    2001-01-01

    For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped

  18. Study on the characterization of the neutron radiography facility in HANARO for two-phase flow research

    Energy Technology Data Exchange (ETDEWEB)

    Lim, I. C.; Seo, C. G.; Jeong, J. H.; Lee, B. H.; Choi, Y. S

    2001-01-01

    For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.

  19. Development of advanced neutron radiography for inspection on irradiated fuels and materials (2). Observation of hydride and oxide film on zircaloy cladding by using neutron radiography

    International Nuclear Information System (INIS)

    Yasuda, Ryou; Nakata, Masahito; Mastubayashi, Masahito; Harada, Katsuya

    2001-02-01

    Neutron radiography has been used as available diagnosis method of integrity on irradiated fuels, and has not been employed for estimating hydride and oxide film, which are influenced on integrity of Zircaloy cladding. Preliminary tests for PIE were carried out to assess possibility of neutron radiography as evaluation tool for hydrided and oxide film on the cladding. In these experiments, Zircaloy claddings with controlled amount of hydrogen absorption (200, 500, and 1000ppm) and thickness of oxide film were radiographed in center axis and in side directions of cladding tube by neutron imaging plate method. It is noted that thickness of oxide film was formed range from 7 μ m to 70 μ m at various temperatures (973, 1173, and 1323K) under steam atmosphere on the Zircaloy claddings. CT (Computed Tomography) restructure calculation was carried out to obtain cross section image of the claddings non-destructively. The Radiographs were qualitatively investigated about structure formation area and dependence of hydrogen absorption amount on PSL (Photo Simulated Luminescence) and CT values using by image analysis processor. At the results of imaging plate test, obvious difference was not found out between hydride formation (except for 1000ppm cladding) and standard claddings in side direction image. However, on the center axis direction image, outer circumference in the cladding cross-section that corresponded with hydride segregation area became blacker. In the case of oxide film formed cladding images, although oxide film could not find out on all speciments in the radiographs taken at the center axis and side directions, cross-section of claddings heat-processed at 973K showed appreciable blackness increasing with oxide film thickness on the radiographs. On the other hand, there is no effective difference between images of oxide film formed claddings processed at 1173K and 1323K and that of standard cladding. In CT image of 1000ppm hydrogen absorbed cladding, it is

  20. Dehydration of moulding sand in simulated casting process examined with neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Schillinger, B., E-mail: Burkhard.Schillinger@frm2.tum.de [Technische Universitaet Muenchen, FRM II and Faculty for Physics E21, Lichtenbergstr. 1, 85748 Garching (Germany); Calzada, E. [Technische Universitaet Muenchen, FRM II and Faculty for Physics E21, Lichtenbergstr. 1, 85748 Garching (Germany); Eulenkamp, C.; Jordan, G.; Schmahl, W.W. [Ludwig-Maximilians-Universitaet Muenchen, Department fuer Geo- und Umweltwissenschaften, Sektion Kristallographie, Theresienstr. 41, 80333 Muenchen (Germany)

    2011-09-21

    Natural bentonites are an important material in the casting industry. Smectites as the main component of bentonites plasticize and stabilise sand moulds. Pore water as well as interlayer water within the smectites are lost as a function of time, location and temperature. Although rehydration of the smectites should be a reversible process, the industrially dehydrated smectites lose their capability to reabsorb water. This limits the number of possible process cycles of the mould material. A full understanding of the dehydration process would help to optimise the amount of fresh material to be added and thus save resources. A simulated metal casting was investigated with neutron radiography at the ANTARES neutron imaging facility of the FRM II reactor of Technische Universitaet Muenchen, Germany.

  1. Cf-252 based neutron radiography using real-time image processing system

    International Nuclear Information System (INIS)

    Mochiki, Koh-ichi; Koiso, Manabu; Yamaji, Akihiro; Iwata, Hideki; Kihara, Yoshitaka; Sano, Shigeru; Murata, Yutaka

    2001-01-01

    For compact Cf-252 based neutron radiography, a real-time image processing system by particle counting technique has been developed. The electronic imaging system consists of a supersensitive imaging camera, a real-time corrector, a real-time binary converter, a real-time calculator for centroid, a display monitor and a computer. Three types of accumulated NR image; ordinary, binary and centroid images, can be observed during a measurement. Accumulated NR images were taken by the centroid mode, the binary mode and ordinary mode using of Cf-252 neutron source and those images were compared. The centroid mode presented the sharpest image and its statistical characteristics followed the Poisson distribution, while the ordinary mode showed the smoothest image as the averaging effect by particle bright spots with distributed brightness was most dominant. (author)

  2. Comparative examination of the fresh and spent nuclear TRIGA fuel by neutron radiography

    International Nuclear Information System (INIS)

    Dinca, M.

    2016-01-01

    At the Institute for Nuclear Research (INR) there is in operation an underwater (wet) neutron radiography facility (INUM) designed especially for nuclear fuel investigation. INUM was involved in CANDU experimental type and TRIGA type nuclear fuel investigations. In this paper are presented the results after investigation of the nuclear fuel TRIGA-HEU and TRIGA-LEU, fresh and spent, using transfer method with metallic foils of dysprosium and indium and radiographic films (38 cm x 10 cm). This method is the most suitable for spent fuel and offers a high geometrical resolution of the images that subsequently are digitalized with a professional scanner for films. From the images obtained for TRIGA-HEU and TRIGA-LEU with different degree of burn-up there are established the opportunities to use dysprosium or indium converter foils based on their response to thermal or epithermal neutrons to evaluate the degree of burn-up, dimensional measurements, defects etc. (authors)

  3. Visualization of bed material movement in a simulated fluidized bed heat exchanger by neutron radiography

    International Nuclear Information System (INIS)

    Umekawa, Hisashi; Ozawa, Mamoru; Takenaka, Nobuyuki; Matsubayashi, Masahito

    1999-01-01

    The bulk movement of fluidized bed material was visualized by neutron radiography by introducing tracers into the bed materials. The simulated fluidized bed consisted of aluminum plates, and the bed material was sand of 99.7% SiO 2 (mean diameter: 0.218 mm, density: 2555 kg/m 3 ). Both materials were almost transparent to neutrons. Then the sand was colored by the contamination of the sand coated by CdSO 4 . Tracer particles of about 2 mm diameter were made by the B 4 C, bonded by the vinyl resin. The tracer was about ten times as large as the particle of fluidized bed material, but the traceability was enough to observe the bed-material bulk movement owing to the large effective viscosity of the fluidized bed. The visualized images indicated that the bubbles and/or wakes were important mechanism of the behavior of the fluidized bed movement

  4. Development of high-frame rate neutron radiography and quantitative measurement method for multiphase flow research

    International Nuclear Information System (INIS)

    Mishima, K.; Hibiki, T.

    1998-01-01

    Neutron radiography (NR) is one of the radiographic techniques which makes use of the difference in attenuation characteristics of neutrons in materials. Fluid measurement using the NR technique is a non-intrusive method which enables visualization of dynamic images of multiphase flow of opaque fluids and/or in a metallic duct. To apply the NR technique to multiphase flow research, high frame-rate NR was developed by combining up-to-date technologies for neutron sources, scintillator, high-speed video and image intensifier. This imaging system has several advantages such as a long recording time (up to 21 minutes), high-frame-rate (up to 1000 frames/s) imaging and there is no need for a triggering signal. Visualization studies of air-water two-phase flow in a metallic duct and molten metal-water interaction were performed at recording speeds of 250, 500 and 1000 frames/s. The qualities of the consequent images were sufficient to observe the flow pattern and behavior. It was also demonstrated that some characteristics of two-phase flow could be measured from these images in collaboration with image processing techniques. By utilizing geometrical information extracted from NR images, data on flow regime, bubble rise velocity, and wave height and interfacial area in annular flow were obtained. By utilizing attenuation characteristics of neutrons in materials, measurements of void profile and average void fraction were performed. It was confirmed that this new technique may have significant advantages both in visualizing and measuring high-speed fluid phenomena when other methods, such as an optical method and X-ray radiography, cannot be applied. (author)

  5. Proposed power upgrade of the hot fuel examination facility's neutron radiography reactor

    International Nuclear Information System (INIS)

    Pruett, D.P.; Richards, W.J.; Heidel, C.C.

    1984-01-01

    The Hot Fuel Examination Facility, HFEF, is one of several facilities located at the Argonne Site. HFEF comprises a large hot cell where both non-destructive and destructive examination of highly-irradiated reactor fuels are conducted in support of the LMFBR program. One of the non-destructive examination techniques utilized at HFEF is neutron radiography. When the NRAD facility was designed and constructed, an operating power level of 250 kw was considered to be adequate for obtaining radiographs of the type of specimens envisaged at that time. Since that time, several things have occurred that have tended to increase radiography exposure times to as much as 90 minutes each. In order to decrease exposure times, the reactor power level is to be increased from 250 kW to 1 MW. This increase in power will necessitate several engineering and design changes. The proposed upgrade of the NRAD facility will increase the neutron flux available in the beam tubes appreciably. The increased flux will enable NRAD to continue to meet its operational commitments in a timely manner and to develop state-of-the-art techniques in the future as it has in the past

  6. Non-destructive investigation of a time capsule using neutron radiography and X-ray fluorescence

    Science.gov (United States)

    MacDonald, B. L.; Vanderstelt, J.; O'Meara, J.; McNeill, F. E.

    2016-01-01

    Non-destructive analytical techniques are becoming increasingly important for the study of objects of cultural heritage interest. This study applied two techniques: X-ray fluorescence and neutron radiography, for the investigation of a capped, tubular metal object recovered from an urban construction site in Gore Park, Hamilton, Canada. The site is an urban park containing a World War I commemorative monument that underwent renovation and relocation. Historical documentation suggested that the object buried underneath the monument was a time capsule containing a paper document listing the names of 1800 Canadians who died during WWI. The purpose of this study was to assess the condition of the object, and to verify if it was what the historical records purported. XRF analysis was used to characterize the elemental composition of the metal artifact, while neutron radiography revealed that its contents were congruent with historical records and remained intact after being interred for 91 years. Results of this study demonstrate the value of non-destructive techniques for the analysis and preservation of cultural heritage.

  7. Application of neutron radiography and tomography for analysis of root morphology of growing ginseng

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Ho; Sung, Bong Jae; Park, Jong Yoon [Geumsan Agricultural Development and Technology Center, Geumsan (Korea, Republic of); Sim, Cheul Muu; Kim, Young Jin; Lee, Seung Wook [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2005-07-01

    The shape of main root of ginseng is very important for its commercial value. The morphology of main root is predominantly determined by the root-growing pattern in one year after transplantation of ginseng seedling(one years root). There are many factors affecting the root growing of young ginseng but no systematic approach has been applied to find the effects of various factors. The main reason for this was no method was sought to see the root shapes non-destructively. Neutron radiography is thought to be an appropriate NDT method for root morphology examination in ginseng and a study on using NR for the research on ginseng is being conducted. Considering that the live plants should be moved to the reactor site for their examination of four or five times per year at least, the pot growing method is indispensable. The pot should contain enough soils for growing-up of ginseng and its maximum size is limited to have good contrast in neutron radiography image of ginseng root. Thus, a preliminary radiographic study was performed to find the proper size of ginseng pot using the NR facility of HANARO. Several pots will be prepared for young ginsengs and they will be examined for about one year.

  8. Non-destructive investigation of a time capsule using neutron radiography and X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, B.L., E-mail: macdonbl@mcmaster.ca [McMaster University, Department of Medical Physics and Applied Radiation Sciences, Hamilton (Canada); Vanderstelt, J., E-mail: joshv@nray.ca [Nray Services Inc., 56A Head Street, Dundas, ON (Canada); O’Meara, J. [University of Guelph, Department of Physics, Guelph (Canada); McNeill, F.E. [McMaster University, Department of Medical Physics and Applied Radiation Sciences, Hamilton (Canada)

    2016-01-15

    Non-destructive analytical techniques are becoming increasingly important for the study of objects of cultural heritage interest. This study applied two techniques: X-ray fluorescence and neutron radiography, for the investigation of a capped, tubular metal object recovered from an urban construction site in Gore Park, Hamilton, Canada. The site is an urban park containing a World War I commemorative monument that underwent renovation and relocation. Historical documentation suggested that the object buried underneath the monument was a time capsule containing a paper document listing the names of 1800 Canadians who died during WWI. The purpose of this study was to assess the condition of the object, and to verify if it was what the historical records purported. XRF analysis was used to characterize the elemental composition of the metal artifact, while neutron radiography revealed that its contents were congruent with historical records and remained intact after being interred for 91 years. Results of this study demonstrate the value of non-destructive techniques for the analysis and preservation of cultural heritage.

  9. On-line video image processing system for real-time neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Fujine, S; Yoneda, K; Kanda, K [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.

    1983-09-15

    The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 distinct colors on a RGB video display. The direct image of this system could be satisfactory for penetrating the side plates to test MTR type reactor fuels and for the investigation of moving objects.

  10. Neutron radiography characterization of an operating proton exchange membrane fuel cell with localized current distribution measurements

    International Nuclear Information System (INIS)

    Gagliardo, J.J.; Owejan, J.P.; Trabold, T.A.; Tighe, T.W.

    2009-01-01

    Neutron radiography has proven to be a powerful tool to study and understand the effects of liquid water in an operating fuel cell. In the present work, this experimental method is coupled with locally resolved current and ohmic resistance measurements, giving additional insight into water management and fuel cell performance under a variety of conditions. The effects of varying the inlet humidification level and the current density of the 50 cm 2 cell are studied by simultaneously monitoring electrochemical performance with a 10x10 matrix of current sensors, and liquid water volumes are measured using the National Institute of Standards and Technology (NIST) neutron imaging facility. A counter flow, straight channel proton exchange membrane (PEM) fuel cell is used to demonstrate localized performance loss corresponds to water-filled channels that impede gas transport to the catalyst layer, thereby creating an area that has low current density. Furthermore, certain operating conditions causing excess water accumulation in the channels can result in localized proton resistance increase, a result that can only be accurately observed with combined radiography and distributed electrochemical measurements.

  11. Application of neutron radiography and tomography for analysis of root morphology of growing ginseng

    International Nuclear Information System (INIS)

    Kim, Hyun Ho; Sung, Bong Jae; Park, Jong Yoon; Sim, Cheul Muu; Kim, Young Jin; Lee, Seung Wook

    2005-01-01

    The shape of main root of ginseng is very important for its commercial value. The morphology of main root is predominantly determined by the root-growing pattern in one year after transplantation of ginseng seedling(one years root). There are many factors affecting the root growing of young ginseng but no systematic approach has been applied to find the effects of various factors. The main reason for this was no method was sought to see the root shapes non-destructively. Neutron radiography is thought to be an appropriate NDT method for root morphology examination in ginseng and a study on using NR for the research on ginseng is being conducted. Considering that the live plants should be moved to the reactor site for their examination of four or five times per year at least, the pot growing method is indispensable. The pot should contain enough soils for growing-up of ginseng and its maximum size is limited to have good contrast in neutron radiography image of ginseng root. Thus, a preliminary radiographic study was performed to find the proper size of ginseng pot using the NR facility of HANARO. Several pots will be prepared for young ginsengs and they will be examined for about one year

  12. Distribution of root exudates and mucilage in the rhizosphere: combining 14C imaging with neutron radiography

    Science.gov (United States)

    Holz, Maire; Carminati, Andrea; Kuzyakov, Yakov

    2015-04-01

    Water and nutrients will be the major factors limiting food production in future. Plant roots employ various mechanisms to increase the access to limited soil resources. Low molecular weight organic substances released by roots into the rhizosphere increase nutrient availability by interactions with microorganisms, while mucilage improves water availability under low moisture conditions. Though composition and quality of these substances have intensively been investigated, studies on the spatial distribution and quantification of exudates in soil are scarce. Our aim was to quantify and visualize root exudates and mucilage distribution around growing roots using neutron radiography and 14C imaging depending on drought stress. Plants were grown in rhizotrons well suited for neutron radiography and 14C imaging. Plants were exposed to various soil water contents experiencing different levels of drought stress. The water content in the rhizosphere was imaged during several drying/wetting cycles by neutron radiography. The radiographs taken a few hours after irrigation showed a wet region around the root tips showing the allocation and distribution of mucilage. The increased water content in the rhizosphere of the young root segments was related to mucilage concentrations by parameterization described in Kroener et al. (2014). In parallel 14C imaging of root after 14CO2 labeling of shoots (Pausch and Kuzyakov 2011) showed distribution of rhizodeposits including mucilage. Three days after setting the water content, plants were labeled in 14CO2 atmosphere. Two days later 14C distribution in soil was imaged by placing a phosphor-imaging plate on the rhizobox. To quantify rhizodeposition, 14C activity on the image was related to the absolute 14C activity in the soil and root after destructive sampling. By comparing the amounts of mucilage (neutron radiography) with the amount of total root derived C (14C imaging), we were able to differentiate between mucilage and root

  13. Detection of wood discoloration in a canker fungus-inoculated Japanese cedar by neutron radiography

    International Nuclear Information System (INIS)

    Yamada, T.; Aoki, Y.; Yamato, M.; Komatsu, M.; Kusumoto, D.; Suzuki, K.; Nakanishi, T.M.

    2005-01-01

    Neutron radiography (NRG) was applied to trace the development of discolored tissue in the wood of Japanese cedar (Cryptomeria japonica) after being infected with a canker fungus. Japanese cedar seedlings were wound inoculated with a virulent and avirulent isolate of a canker fungus, Guignardia cryptomeriae. Three, 7, 13 and 22 days after the inoculation, the seedlings were irradiated with thermal neutrons. The image on the X-ray film showed that the whiteness in the image corresponded to the water content in the sample. Discolored tissue and surrounding dry zones induced by the fungal inoculation were detected as dark areas, indicating water deficiency with a high resolution. Through image analysis, the dry zones were detected as early as 3 days after inoculation. Neutron images also showed the difference in the size of water deficient parts due to the tissue damage among the treatments. The neutron beam dose used in this experiment had no effect on the growth rate of the fungus on a medium, showing that NRG is an effective method for pathological research of trees. (author)

  14. Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess; Thomas L. Maddock; Margaret A. Marshall; Leland M. Montierth

    2011-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has been evaluated as an acceptable benchmark experiment. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has not been evaluated as it is very similar to the evaluated core configuration. The benchmark eigenvalue is 1.0012 ± 0.0029. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  15. Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess; Thomas L. Maddock; Margaret A. Marshall; Leland M. Montierth

    2013-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has been evaluated as an acceptable benchmark experiment. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  16. Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Maddock, Thomas L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Marshall, Margaret A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Montierth, Leland M. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Ning [Idaho National Lab. (INL), Idaho Falls, ID (United States); Phillips, Ann Marie [Idaho National Lab. (INL), Idaho Falls, ID (United States); Schreck, Kenneth A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Briggs, J. Blair [Idaho National Lab. (INL), Idaho Falls, ID (United States); Woolstenhulme, Eric W. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bolin, John M. [General Atomics, San Diego, CA (United States); Veca, Anthony [General Atomics, San Diego, CA (United States); McKnight, Richard D. [Argonne National Lab. (ANL), Argonne, IL (United States); Lell, Richard M. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has been evaluated as an acceptable benchmark experiment. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has not been evaluated as it is very similar to the evaluated core configuration. The benchmark eigenvalue is 1.0012 ± 0.0029. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  17. Improving the beam quality of the neutron radiography facility using the SLOWPOKE-2 at the Royal Military College of Canada

    International Nuclear Information System (INIS)

    Lewis, W.J.; Bennett, L.G.I.; Teshima, P.

    1996-01-01

    At the SLOWPOKE-2 Facility at the Royal Military College of Canada, a neutron radiography facility has been designed and installed, and the beam quality has been improved by performing a series of radiographs using American standard for testing and materials (ASTM) E 545 indicators. Other means of determining the progress such as bubble detectors and activation foils were used. Modifications to the nosepiece of the beam tube including shielding and linings for fast neutron and gamma radiation were made. (orig.)

  18. Neutron radiography experiments for verification of soluble boron mixing and transport modeling under natural circulation conditions

    International Nuclear Information System (INIS)

    Morlang, M.M.; Feltus, M.A.

    1996-01-01

    The use of neutron radiography for visualization of fluid flow through flow visualization modules has been very successful. Current experiments at the Penn State Breazeale Reactor serve to verify the mixing and transport of soluble boron under natural flow conditions as would be experienced in a pressurized water reactor. Different flow geometries have been modeled including holes, slots, and baffles. Flow modules are constructed of aluminum box material 1 1/2 inches by 4 inches in varying lengths. An experimental flow system was built which pumps fluid to a head tank and natural circulation flow occurs from the head tank through the flow visualization module to be radio-graphed. The entire flow system is mounted on a portable assembly to allow placement of the flow visualization module in front of the neutron beam port. A neutron-transparent fluor-inert fluid is used to simulate water at different densities. Boron is modeled by gadolinium oxide powder as a tracer element, which is placed in a mixing assembly and injected into the system a remotely operated electric valve, once the reactor is at power. The entire sequence is recorded on real-time video. Still photographs are made frame-by-frame from the video tape. Computers are used to digitally enhance the video and still photographs. The data obtained from the enhancement will be used for verification of simple geometry predictions using the TRAC and RELAP thermal-hydraulic codes. A detailed model of a reactor vessel inlet plenum, downcomer region, flow distribution area and core inlet is being constructed to model the APGOO plenum. Successive radiography experiments of each section of the model under identical conditions will provide a complete vessel / core model for comparison with the thermal-hydraulic codes

  19. Neutron radiography experiments for verification of soluble boron mixing and transport modeling under natural circulation conditions

    International Nuclear Information System (INIS)

    Feltus, M.A.; Morlang, G.M.

    1996-01-01

    The use of neutron radiography for visualization of fluid flow through flow visualization modules has been very successful. Current experiments at the Penn State Breazeale Reactor serve to verify the mixing and transport of soluble boron under natural flow conditions as would be experienced in a pressurized water reactor. Different flow geometries have been modeled including holes, slots, and baffles. Flow modules are constructed of aluminum box material 1 1/2 inches by 4 inches in varying lengths. An experimental flow system was built which pumps fluid to a head tank and natural circulation flow occurs from the head tank through the flow visualization module to be radiographed. The entire flow system is mounted on a portable assembly to allow placement of the flow visualization module in front of the neutron beam port. A neutron-transparent fluorinert fluid is used to simulate water at different densities. Boron is modeled by gadolinium oxide powder as a tracer element, which is placed in a mixing assembly and injected into the system by remote operated electric valve, once the reactor is at power. The entire sequence is recorded on real-time video. Still photographs are made frame-by-frame from the video tape. Computers are used to digitally enhance the video and still photographs. The data obtained from the enhancement will be used for verification of simple geometry predictions using the TRAC and RELAP thermal-hydraulic codes. A detailed model of a reactor vessel inlet plenum, downcomer region, flow distribution area and core inlet is being constructed to model the AP600 plenum. Successive radiography experiments of each section of the model under identical conditions will provide a complete vessel/core model for comparison with the thermal-hydraulic codes

  20. Study on characteristics of void fraction in vertical countercurrent two-phase flow by neutron radiography

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito; Sudo, Yukio; Haga, Katsuhiro

    1996-01-01

    In order to make clear the flow mechanism and characteristics of falling water limitation under the countercurrent two-phase flow, that is, the countercurrent flow limitation (CCFL), in a vertical channel, a technique of neutron radiography (NRG) provided in the Research Nuclear Reactor JRR-3M was applied to an air-water system of vertical rectangular channels of 50 and 782 mm in length with 66 mm in channel width and 2.3 mm in channel gap under atmospheric pressure. The neutron radiography facility used in this study has a high thermal neutron flux that is suitable for visualization of fluid phenomena. A real-time electronic imaging method was used for capturing two-phase flow images in a vertical channel. It was found the technique applied was very potential to clarify the characteristics of instantaneous, local and average void fractions which were important to understand flow mechanism of the phenomena, while the measurements of void fraction had not been applied fully effectively to understanding of the flow mechanism of CCFL, because the differential pressure for determining void fraction is, in general, too small along the tested channel and is fluctuating too frequently to be measured accurately enough. From the void fraction measured by NRG as well as through direct flow observation, it was revealed that the shorter side walls of rectangular channel tested were predominantly wetted by water falling down with the longer side walls being rather dry by ascending air flow. It was strongly suggested that the analytical flow model thus obtained and proposed for the CCFL based on the flow observation was most effective

  1. Measurement of vapor behavior in tight-lattice bundles by neutron radiography

    International Nuclear Information System (INIS)

    Kureta, Masatoshi; Akimoto, Hajime

    2004-01-01

    Three-dimensional and instantaneous void fractions in tight-lattice 7-rod and 14-rod bundles were measured by neutron radiography in order to make clear the flow behavior and to verify the advanced fine-mesh numerical analysis codes for the R and D of the Reduced-Moderation Water Reactors (RMWR). Time-averaged 3D void fraction distribution is evaluated with the spatial resolution of 0.1 - 0.2 mm using neutron tomography, and consecutive change of vapor behavior is observed quantitatively with time step of 1 ms using high-frame-rate neutron radiography (HFR-NR). In this paper, void fraction distribution and vapor behavior of flow boiling of water in tight-lattice rod bundles are focused on and discussed based on the obtained results. 'High void fraction spot', 'void drift phenomenon', and 'vapor chimney' were observed under atmospheric pressure conditions. Here, 'high void fraction spot' indicates that high void fraction regions are appeared between adjacent rods, narrow space, at/near point of net vapor generation region. 'Void drift' and 'vapor chimney' represent that high void fraction region moves to wide triangular space and is formed a vapor flow channel so-called 'vapor chimney'. It was confirmed from the time-averaged 3D data that void fraction in the center is higher than that in the periphery. On the other hand, it was found from the HFR-NR experiments that big vapor bubbles and/or cluster flow upward intermittently not only in the center but in the periphery of the channel and, therefore, point of net vapor generation is scattered statistically in wide region. (author)

  2. Complementary X-ray and neutron radiography study of the initial lithiation process in lithium-ion batteries containing silicon electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Fu, E-mail: fu.sun@helmholtz-berlin.de [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Markötter, Henning [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Manke, Ingo; Hilger, André [Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Alrwashdeh, Saad S. [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Mechanical Engineering Department, Faculty of Engineering, Mu' tah University, P.O. Box 7, Al-Karak 61710 Jordan (Jordan); Kardjilov, Nikolay [Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Banhart, John [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany)

    2017-03-31

    Highlights: • A radiography cell for in operando X-ray radiography was designed and built. • A self-assembled CR2032 coin cell was built for in operando neutron radiography. • In operando X-ray and neuron radiography were conducted by using Si electrode half cells. - Abstract: Complementary in operando X-ray radiography and neutron radiography measurements were conducted to investigate and visualize the initial lithiation in silicon-electrode lithium-ion batteries. By means of X-ray radiography, a significant volume expansion of Si particles and the Si electrode during the first discharge was observed. In addition, many Si particles were found that never undergo electrochemical reactions. These findings were confirmed by neutron radiography, which, for the first time, showed the process of Li alloying with the Si electrode during initial lithiation. These results demonstrate that complementary X-ray and neutron radiography is a powerful tool to investigate the lithiation mechanisms inside Si-electrode based lithium-ion batteries.

  3. The new neutron radiography/tomography/imaging station DINGO at OPAL

    International Nuclear Information System (INIS)

    Garbe, U.; Randall, T.; Hughes, C.

    2011-01-01

    A new neutron imaging instrument will be built to support the area of neutron imaging research (neutron radiography/tomography) at ANSTO. The instrument will be designed for an international user community and for routine quality control for defence, industrial, mining, space and aircraft applications. It will also be a useful tool for assessing oil and water flow in sedimentary rock reservoirs (like the North West Shelf), assessing water damage in aircraft components, and the study of hydrogen distribution and cracking in steel. The instrument is planned to be completed by the end of June 2013 and is currently in the design stage. The usable neutron flux is mainly determined by the neutron source, but it also depends on the instrument position and the resolution. The designated instrument position for DINGO is the beam port HB-2 in the reactor hall. The estimated flux for an L/D of approximately 250 at HB-2 is calculated by Mcstas simulation in a range of 4.75x10 7 n/cm 2 s, which is in the same range of other facilities like ANSTARES (FRM II; Schillinger et al., 2004 ) or BT2 (NIST; Hussey et al., 2005 ). A special feature of DINGO is the in-pile collimator place in front of the main shutter at HB-2. The collimator offers two pinholes with a possible L/D of 250 and 1000. A secondary collimator will separate the two beams and block one. The whole instrument will operate in two different positions, one for high resolution and the other for high speed.

  4. The new neutron radiography/tomography/imaging station DINGO at OPAL

    Science.gov (United States)

    Garbe, U.; Randall, T.; Hughes, C.

    2011-09-01

    A new neutron imaging instrument will be built to support the area of neutron imaging research (neutron radiography/tomography) at ANSTO. The instrument will be designed for an international user community and for routine quality control for defence, industrial, mining, space and aircraft applications. It will also be a useful tool for assessing oil and water flow in sedimentary rock reservoirs (like the North West Shelf), assessing water damage in aircraft components, and the study of hydrogen distribution and cracking in steel. The instrument is planned to be completed by the end of June 2013 and is currently in the design stage. The usable neutron flux is mainly determined by the neutron source, but it also depends on the instrument position and the resolution. The designated instrument position for DINGO is the beam port HB-2 in the reactor hall. The estimated flux for an L/ D of approximately 250 at HB-2 is calculated by Mcstas simulation in a range of 4.75×10 7 n/cm 2 s, which is in the same range of other facilities like ANSTARES (FRM II; Schillinger et al., 2004 [1]) or BT2 (NIST; Hussey et al., 2005 [2]). A special feature of DINGO is the in-pile collimator place in front of the main shutter at HB-2. The collimator offers two pinholes with a possible L/ D of 250 and 1000. A secondary collimator will separate the two beams and block one. The whole instrument will operate in two different positions, one for high resolution and the other for high speed.

  5. Computational Analysis Supporting the Design of a New Beamline for the Mines Neutron Radiography Facility

    Science.gov (United States)

    Wilson, C.; King, J.

    The Colorado School of Mines installed a neutron radiography system at the United States Geological Survey TRIGA reactor in 2012. An upgraded beamline could dramatically improve the imaging capabilities of this system. This project performed computational analyses to support the design of a new beamline, with the major goals of minimizing beam divergence and maximizing beam intensity. The new beamline will consist of a square aluminum tube with an 11.43 cm (4.5 in) inner side length and 0.635 cm (0.25 in) thick walls. It is the same length as the original beam tube (8.53 m) and is composed of 1.22 m (4 ft) and 1.52 m (5 ft) flanged sections which bolt together. The bottom 1.22 m of the beamline is a cylindrical aluminum pre-collimator which is 0.635 cm (0.25 in) thick, with an inner diameter of 5.08 cm (2 in). Based on Monte Carlo model results, when a pre-collimator is present, the use of a neutron absorbing liner on the inside surface of the beam tube has almost no effect on the angular distribution of the neutron current at the collimator exit. The use of a pre-collimator may result in a non-uniform flux profile at the image plane; however, as long as the collimator is at least three times longer than the pre-collimator, the flux distortion is acceptably low.

  6. Radiography apparatus using gamma rays emitted by water activated by fusion neutrons

    Science.gov (United States)

    Smith, Donald L.; Ikeda, Yujiro; Uno, Yoshitomo

    1996-01-01

    Radiography apparatus includes an arrangement for circulating pure water continuously between a location adjacent a source of energetic neutrons, such as a tritium target irradiated by a deuteron beam, and a remote location where radiographic analysis is conducted. Oxygen in the pure water is activated via the .sup.16 O(n,p).sup.16 N reaction using .sup.14 -MeV neutrons produced at the neutron source via the .sup.3 H(d,n).sup.4 He reaction. Essentially monoenergetic gamma rays at 6.129 (predominantly) and 7.115 MeV are produced by the 7.13-second .sup.16 N decay for use in radiographic analysis. The gamma rays have substantial penetrating power and are useful in determining the thickness of materials and elemental compositions, particularly for metals and high-atomic number materials. The characteristic decay half life of 7.13 seconds of the activated oxygen is sufficient to permit gamma ray generation at a remote location where the activated water is transported, while not presenting a chemical or radioactivity hazard because the radioactivity falls to negligible levels after 1-2 minutes.

  7. Study of building materials impregnation processes by quasi-real-time neutron radiography

    International Nuclear Information System (INIS)

    Nemec, T.; Rant, J.; Apih, V.; Glumac, B.

    1999-01-01

    Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be presented. Quantitative results obtained by NR imaging successfully explained the processes that occur during the impregnation of porous materials. Efficiency of hydrophobic treatment was quantitatively evaluated

  8. Quantitative flow visualization of fluidized-bed heat exchanger by neutron radiography

    International Nuclear Information System (INIS)

    Ozawa, M.; Umekawa, H.; Furui, S.; Hayashi, K.; Takenaka, N.

    2004-01-01

    Quantitative flow visualization of a gas-solid fluidized-bed installed vertical tube-bank has been successfully conducted using neutron radiography and image processing technique. The quantitative data of void fraction distribution as well as the fluctuation data are presented. The time-averaged void fraction is well correlated by the drift-flux model. The bubbles formed in the bed, rise along the vertical tubes and the observed bubble size is smaller than that in a free bubbling bed without tube-banks. The bubble diameter is well correlated by the modified Mori and Wen's correlation taking into account the pitch of tube arrangement. The bubble rise velocity is also well correlated by applying the drift-flux model. These results are consistent for both bed materials of Geldart's B- and A-particles, while the bubble size is significantly different between two kinds of particles

  9. Determination of capillary motion of water in bricks using neutron radiography

    International Nuclear Information System (INIS)

    Czachor, A.; Abd El-Ghany El-Abd; Milczarek, J.J.

    2002-01-01

    Vertical migration of water in several porous materials has been directly observed and recorded with the recently installed neutron and gamma radiography facility at Maria reactor of Institute of Atomic Energy, Swierk. The density profiles of water in samples were obtained from the optical density of digitalised images. A simple model (representing the porous material as a collection of capillary tubes of various radii) has been introduced to describe the liquid transport in porous materials in terms of capillary motion. The equation for viscous movement of water in porous material in presence of the gravitation is proposed. A good agreement of the calculated density profiles for vertical water migration with the data collected for siliceous bricks suggests that the thinnest capillary tubes determine the upper edge of the water density profile. (author)

  10. Quantification of water penetration into concrete through cracks by neutron radiography

    International Nuclear Information System (INIS)

    Kanematsu, M.; Maruyama, I.; Noguchi, T.; Iikura, H.; Tsuchiya, N.

    2009-01-01

    Improving the durability of concrete structures is one of the ways to contribute to the sustainable development of society, and it has also become a crucial issue from an environmental viewpoint. It is well known that moisture behavior in reinforced concrete is linked to phenomena such as cement hydration, volume change and cracking caused by drying shrinkage, rebar corrosion and water leakage that affect the durability of concrete. In this research, neutron radiography was applied for visualization and quantification of water penetration into concrete through cracks. It is clearly confirmed that TNR can make visible the water behavior in/near horizontal/vertical cracks and can quantify the rate of diffusion and concentration distribution of moisture with high spatial and time resolution. On detailed analysis, it is observed that water penetrates through the crack immediately after pouring and its migration speed and distribution depend on the moisture condition in the concrete.

  11. Measuring a ballooning gap size of irradiated fuels by the indirect method of neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Cheul Muu; Lee, Seung Wook; Lim, In Cheol; Hong, Kwang Pyo; Kim, Young Jin

    2003-11-01

    An indirect method of a neutron radiography is mobilized for inspecting post irradiated nuclear fuel pins, UO{sub 2}Si clad with Al, which swallowing, crack, ballooning, plug gap, thinning and so on, occurred. The system of an indirect method consists of a cask of carrying fuel pins, Dy converter, linear controller of converter, camera of monitoring fuel cassette. The nuclear sample pins of RISO and KAERI are exposed for 25 min. at the first exposure room, 10{sup 7} cm{sup 2}/sec flux. An activation image formed in the Dy foil is subsequently transferred in a dark room for a more than 8 hours to SR film using the decay radiation. Due to L/D ratio an unsharpness of 9.82{approx}14{mu}m and a magnification of 1.0003 are given. After digitizing an image of SR film, the ballooning gap of plug is discernible by H/V filter of image processing.

  12. Visualization of water penetration in cementitious materials with superabsorbent polymers by means of neutron radiography

    International Nuclear Information System (INIS)

    Snoeck, D.; Steuperaert, S.; Van Tittelboom, K.; Dubruel, P.; De Belie, N.

    2012-01-01

    Concrete cracks due to its low tensile strength. As both harmful gases and fluids may enter the concrete by migrating into cracks, the durability is endangered. The service life decreases, repair costs rise and buildings could structurally decline. In the current research, crack sealing is enhanced by the use of superabsorbent polymers (SAP). When cracking occurs, SAP particles are exposed to the humid environment and swell, sealing the crack. By means of neutron radiography, the moisture distribution is studied during capillary absorption and water permeability tests. Capillary absorption in a crack and water permeability through a crack are reduced in specimens containing SAP particles. SAP particles are able to seal the crack, thus allowing a recovery of the water-tightness of the structure. The total uptake of potentially harmful substances hereby lowers, leading to an enhanced long-term durability and lower maintenance costs.

  13. Measuring a ballooning gap size of irradiated fuels by the indirect method of neutron radiography

    International Nuclear Information System (INIS)

    Sim, Cheul Muu; Lee, Seung Wook; Lim, In Cheol; Hong, Kwang Pyo; Kim, Young Jin

    2003-11-01

    An indirect method of a neutron radiography is mobilized for inspecting post irradiated nuclear fuel pins, UO 2 Si clad with Al, which swallowing, crack, ballooning, plug gap, thinning and so on, occurred. The system of an indirect method consists of a cask of carrying fuel pins, Dy converter, linear controller of converter, camera of monitoring fuel cassette. The nuclear sample pins of RISO and KAERI are exposed for 25 min. at the first exposure room, 10 7 cm 2 /sec flux. An activation image formed in the Dy foil is subsequently transferred in a dark room for a more than 8 hours to SR film using the decay radiation. Due to L/D ratio an unsharpness of 9.82∼14μm and a magnification of 1.0003 are given. After digitizing an image of SR film, the ballooning gap of plug is discernible by H/V filter of image processing

  14. Application of neutron radiography to visualize the distribution of lithium in lithium batteries

    International Nuclear Information System (INIS)

    Kamata, Masahiro; Esaka, Takao; Fujine, Sigenori; Yoneda, Kenji; Kanda, Keiji.

    1995-01-01

    The authors have tried to visualize the motion of lithium ions in lithium ion conductors such as Li 1.33 Ti 1.67 O 4 at high temperatures using neutron radiography (NR) technique and confirmed that NR is very effective to the 6 Li containing systems. This means NR may be used as a non-destructive investigating method to study the electrode reactions and the mass transfer in lithium batteries. Here in this work, it was tried to visualize the distribution of lithium in commercial lithium batteries before and after discharge using NR technique. Obtained NR images will be presented with brief explanation on NR method. Further explanations on the principle of NR and on the NR facilities were presented elsewhere. (J.P.N.)

  15. Simulations Of Neutron Beam Optic For Neutron Radiography Collimator Using Ray Tracing Methodology

    International Nuclear Information System (INIS)

    Norfarizan Mohd Said; Muhammad Rawi Mohamed Zin

    2014-01-01

    Ray- tracing is a technique for simulating the performance of neutron instruments. McStas, the open-source software package based on a meta-language, is a tool for carrying out ray-tracing simulations. The program has been successfully applied in investigating neutron guide design, flux optimization and other related areas with high complexity and precision. The aim of this paper is to discuss the implementation of ray-tracing technique with McStas for simulating the performance of neutron collimation system developed for imaging system of TRIGA RTP reactor. The code for the simulation was developed and the results are presented. The analysis of the performance is reported and discussed. (author)

  16. Hysteresis of Soil Point Water Retention Functions Determined by Neutron Radiography

    Science.gov (United States)

    Perfect, E.; Kang, M.; Bilheux, H.; Willis, K. J.; Horita, J.; Warren, J.; Cheng, C.

    2010-12-01

    Soil point water retention functions are needed for modeling flow and transport in partially-saturated porous media. Such functions are usually determined by inverse modeling of average water retention data measured experimentally on columns of finite length. However, the resulting functions are subject to the appropriateness of the chosen model, as well as the initial and boundary condition assumptions employed. Soil point water retention functions are rarely measured directly and when they are the focus is invariably on the main drying branch. Previous direct measurement methods include time domain reflectometry and gamma beam attenuation. Here we report direct measurements of the main wetting and drying branches of the point water retention function using neutron radiography. The measurements were performed on a coarse sand (Flint #13) packed into 2.6 cm diameter x 4 cm long aluminum cylinders at the NIST BT-2 (50 μm resolution) and ORNL-HFIR CG1D (70 μm resolution) imaging beamlines. The sand columns were saturated with water and then drained and rewetted under quasi-equilibrium conditions using a hanging water column setup. 2048 x 2048 pixel images of the transmitted flux of neutrons through the column were acquired at each imposed suction (~10-15 suction values per experiment). Volumetric water contents were calculated on a pixel by pixel basis using Beer-Lambert’s law in conjunction with beam hardening and geometric corrections. The pixel rows were averaged and combined with information on the known distribution of suctions within the column to give 2048 point drying and wetting functions for each experiment. The point functions exhibited pronounced hysteresis and varied with column height, possibly due to differences in porosity caused by the packing procedure employed. Predicted point functions, extracted from the hanging water column volumetric data using the TrueCell inverse modeling procedure, showed very good agreement with the range of point

  17. Visualization of crust in metallic piping through real-time neutron radiography obtained with low intensity thermal neutron flux

    International Nuclear Information System (INIS)

    Luiz, Leandro C.; Crispim, Verginia R.; Ferreira, Francisco J. O.

    2017-01-01

    The presence of crust on the inner walls of metallic ducts impairs transportation because crust completely or partially hinders the passage of fluid to the processing unit and causes damage to equipment connected to the production line. Its localization is crucial. With the development of the electronic imaging system installed at the Argonauta/Nuclear Engineering Institute (IEN)/National Nuclear Energy Commission (CNEN) reactor, it became possible to visualize crust in the interior of metallic piping of small diameter using real-time neutron radiography images obtained with a low neutron flux. The obtained images showed the resistance offered by crust on the passage of water inside the pipe. No discrepancy of the flow profile at the bottom of the pipe, before the crust region, was registered. However, after the passage of liquid through the pipe, images of the disturbances of the flow were clear and discrepancies in the flow profile were steep. This shows that this technique added the assembled apparatus was efficient for the visualization of the crust and of the two-phase flows

  18. Visualization of crust in metallic piping through real-time neutron radiography obtained with low intensity thermal neutron flux

    Energy Technology Data Exchange (ETDEWEB)

    Luiz, Leandro C.; Crispim, Verginia R. [Nuclear Engineering Program, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Ferreira, Francisco J. O. [National Nuclear Energy Commission, CNEN/IEN, Division Reactors, Rio de Janeiro (Brazil)

    2017-06-15

    The presence of crust on the inner walls of metallic ducts impairs transportation because crust completely or partially hinders the passage of fluid to the processing unit and causes damage to equipment connected to the production line. Its localization is crucial. With the development of the electronic imaging system installed at the Argonauta/Nuclear Engineering Institute (IEN)/National Nuclear Energy Commission (CNEN) reactor, it became possible to visualize crust in the interior of metallic piping of small diameter using real-time neutron radiography images obtained with a low neutron flux. The obtained images showed the resistance offered by crust on the passage of water inside the pipe. No discrepancy of the flow profile at the bottom of the pipe, before the crust region, was registered. However, after the passage of liquid through the pipe, images of the disturbances of the flow were clear and discrepancies in the flow profile were steep. This shows that this technique added the assembled apparatus was efficient for the visualization of the crust and of the two-phase flows.

  19. Application of high-frame-rate neutron radiography to fluid measurement

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Hibiki, Takashi

    1997-01-01

    To apply Neutron radiography (NR) technique to multiphase flow research, high frame-rate NR was developed by assembling up-to-date technologies for neutron source, scintillator, high-speed video and image intensifier. This imaging system has several advantages such as a long recording time (up to 21 minutes), high-frame-rate (up to 1000 frames/s) imaging and no need for triggering signal. Visualization studies of air-water two-phase flow in a metallic duct and molten metal-water interaction were performed at the recording speeds of 250, 500 and 1000 frames/s. The qualities of those consecutive images were good enough to observe the flow pattern and behavior. It was demonstrated also that some characteristics of two-phase flow could be measured from those images in collaboration with image processing techniques. By utilizing geometrical information extracted from NR images, data on flow regime, rising velocity of bubbles, and wave height and interfacial area in annular flow could be obtained. By utilizing attenuation characteristics of neutrons in materials, measurements of void profile and average void fraction could be performed. For this purpose, a quantification method, i.e. Σ-scaling method, was proposed based upon the consideration on the effect of scattered neutrons. This method was tested against known void profiles and compared with existing measurement methods and a correlation for void fraction. It was confirmed that this new technique has significant advantages both in visualizing and measuring high-speed fluid phenomena. (J.P.N.)

  20. Neutron and high-contrast X-ray micro-radiography as complementary tools for monitoring organosilicon consolidants in natural building stones

    Czech Academy of Sciences Publication Activity Database

    Slavíková, M.; Krejčí, F.; Kotlík, P.; Jakůbek, J.; Tomandl, Ivo; Vacík, Jiří

    2014-01-01

    Roč. 338, NOV (2014), s. 42-47 ISSN 0168-583X R&D Projects: GA TA ČR TA01010237; GA MŠk(XE) LM2011019 Institutional support: RVO:61389005 Keywords : stone consolidation * neutron radiography * X-ray radiography * Organosilicon consolidants Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.124, year: 2014

  1. Applications of some non destructive testing techniques to the characterization of calcareous rocks: ultrasounds, X and gamma-ray radiography, tomography, neutron radiography

    International Nuclear Information System (INIS)

    Sicardy, O.

    1986-02-01

    NUCLEART Laboratory has been developping various techniques of conservation of art objects made of wood or stone. It has, among others, achieved a technique of strengthening porous stone objects, by resin impregnation followed by polymerization under gamma rays. The good conduct of such operations implies the existence of characterization means, before and after treatment of the objects. Two means of rocks characterization have been studied: - ultrasound techniques, - radiography techniques. The first part consists in a general description of the calcareous rocks morphology and a presentation of the studied specimens. The second part deals with the application of ultrasound techniques to rocks. Experimentally, one pays particular attention to the specific aspects of ultrasounds propagation inside materials like porous rocks, and especially diffusion phenomena. Results were interpreted in terms of propagation medium structure. Practical interest for rocks control through such techniques has been underligned. The third part concerns the application of radiographic techniques to calcareous rocks. Experimental work consists in establishing exposure curves for a wide range of energy, and the images quality determination. Through a statistics approach, and using digitalization techniques, one has done an exhaustive study of the radiographic noise. Moreover two techniques close to conventional radiography were explored: neutron radiography and X-ray tomography. Their specificity and interest in the case of calcareous rocks have been shown [fr

  2. Feasibility of using neutron radiography to inspect the Space Shuttle solid rocket booster aft skirt, forward skirt and frustum. Part 1: Summary report

    Science.gov (United States)

    Barton, J. P.; Bader, J. W.; Brenizer, J. S.; Hosticka, B.

    1992-01-01

    The space shuttle's solid rocket boosters (SRB) include components made primarily of aluminum that are parachuted back for retrieval from the ocean and refurbished for repeated usage. Nondestructive inspection methods used on these aging parts to reduce the risk of unforeseen problems include x-ray, ultrasonics, and eddy current. Neutron radiography tests on segments of an SRB component show that entrapped moisture and naturally occurring aluminum corrosion can be revealed by neutron radiography even if present in only small amounts. Voids in sealant can also be evaluated. Three alternatives are suggested to follow-up this study: (1) take an SRB component to an existing neutron radiography system; (2) take an existing mobile neutron radiography system to the NASA site; or (3) plan a dedicated system custom designed for NASA applications.

  3. Application of neutron radiography to plant research and water hydrology in soil

    International Nuclear Information System (INIS)

    Nakanishi, T.M.; Matsumoto, Satoshi; Matsumoto, Hisako; Yasunishi, Akiko; Kobayashi, Hisao; Tsuruno, Akira.

    1993-01-01

    Neutron radiography (NR) has been mainly applied in engineering and industrial field. The authors tried to apply NR to plant research to investigate the morphological pattern of the root in the soil as well as the water movement near the root, for the first time in Japan. The authors grew soybean in a thin aluminum container and the sample was irradiated with thermal neutron, periodically, while the growth of the plant. For the morphological change of the root, until the first and the second root development were clearly shown by NR. In the case of water movement near the root, the movement was more clearly shown when the standard sand was used. Since the darkness of the soil correlates well to the deficiency of the soil, image analysis was performed to know the water movement near the root. The gradient of the water content near the root was steeper at the upper half of the root. When water absorbing polymers (polyacrylic polymer and polyvinyl alcohol copolymer), which have been expected to improve the desert for their water sustaining ability, were added to compare the water movement near the root. (author)

  4. Neutron radiography for the study of water uptake in painting canvases and preparation layers

    Energy Technology Data Exchange (ETDEWEB)

    Boon, J.J. [Swiss Institute for Art Research (SIK-ISEA), Zurich (Switzerland); FOM Institute AMOLF, Amsterdam (Netherlands); Hendrickx, R.; Ferreira, E.S.B. [Swiss Institute for Art Research (SIK-ISEA), Zurich (Switzerland); Eijkel, G.; Cerjak, I. [FOM Institute AMOLF, Amsterdam (Netherlands); Kaestner, A. [Paul Scherrer Institut, Neutron Imaging and Activation Group, Laboratory for Neutron Scattering and Imaging, Villigen (Switzerland)

    2015-11-15

    Easel paintings on canvas are subjected to alteration mechanisms triggered or accelerated by moisture. For the study of the spatial distribution and kinetics of such interactions, a moisture exposure chamber was designed and built to perform neutron radiography experiments. Multilayered sized and primed canvas samples were prepared for time-resolved experiments in the ICON cold neutron beamline. The first results show that the set-up gives a good contrast and sufficient resolution to visualise the water uptake in the layers of canvas, size and priming. The results allow, for the first time, real-time visualisation of the interaction of water vapour with such layered systems. This offers important new opportunities for relevant, spatially and time-resolved material behaviour studies and opens the way towards numerical modelling of the process. These first results show that cellulose fibres and glue sizing have a much stronger water uptake than the chalk-glue ground. Additionally, it shows that the uptake rate is not uniform throughout the thickness of the sized canvas. With prolonged moisture exposure, a higher amount of water is accumulating at the lower edge of the canvas weave suggesting a decrease in permeability in the sized canvas with increased water content. (orig.)

  5. Installation and development of neutron radiography in the nuclear reactor (IEAR-1) of the Instituto de Energia Atomica, Brazil

    International Nuclear Information System (INIS)

    Fuga, R.

    1979-01-01

    Investigations on the field of Neutron Radiography have been performed at the IEAR-1, swimming pool reactor utilizing a collimated neutron beam and the so-called photographic transfer method as a mean of detection. The test object (sample) is placed between the neutron source (reactor core) and the gold foil. The acitivity of its different points is the inverse measure of the neutrons absorbed in the test sample at the corresponding points. The activity distribution on the gold foil is determined again by exposing it to an X-ray film. A multichannel type collimator consisting of an assemblage of stainless steel tubes inside an aluminium mantle (tube) was used as a direction beam selector. Improvements have been introduced in respect to the reduction of angular divergence and neutron scattering. To improve further the quality of the radiographs another collimator type has been developed using boric acid as a neutron absorber and moderator. Flux measurements by means of gold foil activation at reactor positions of interest were necessary to eliminate errors originating of different neutron flux values. The dependence of film darkening upon the neutron flux and other factors have been discussed. Finally neutron-and gama-radiographs of the same objects were evaluated in comparison. (author) [pt

  6. Characterization of mono-ethylene-glycol based industrial polyurethanes samples by fast-neutron radiography and neutron tomography

    Science.gov (United States)

    Rogante, Massimo; Söllradl, Stefan

    2016-09-01

    A complicated structural organization of polyurethanes may have a strong influence on the materials functional properties. Under particular conditions such as mechanical and thermal loading and aging, it leads to the material degradation, even in fresh-prepared bulk polymers and especially if defects are present in the material. Unwanted bubbles can be observed, which form during the expansion of the mixture during its chemical reaction and remain present in the final product. These macro-, micro- and nano-bubbles influence the material's performance. In this work, neutron radiography and tomography have been adopted to characterize at a macro-scale level the bulk of commercially available polyurethane samples, obtained from dissimilar- mixture ratios with different densities and branching levels as well as from different zones of the production mould. The characterisation allowed an estimation of the different dense materials - as they are used, e.g., in soles of shoes - as well as the invisible defects like pores and cracks, responsible for the materials fracture by mechanical loading. The obtained information are expected to be useful for various industrial sectors such as automotive and footwear industry. It will be completed by applying SANS, which has already proved to characterize the microstructure of the bulk-polymer with respect to nano-pores, micro-cracks and their arrangement in the polymer matrix.

  7. Characterization of mono-ethylene-glycol based industrial polyurethanes samples by fast-neutron radiography and neutron tomography

    International Nuclear Information System (INIS)

    Rogante, Massimo; Söllradl, Stefan

    2016-01-01

    A complicated structural organization of polyurethanes may have a strong influence on the materials functional properties. Under particular conditions such as mechanical and thermal loading and aging, it leads to the material degradation, even in fresh-prepared bulk polymers and especially if defects are present in the material. Unwanted bubbles can be observed, which form during the expansion of the mixture during its chemical reaction and remain present in the final product. These macro-, micro- and nano-bubbles influence the material's performance. In this work, neutron radiography and tomography have been adopted to characterize at a macro-scale level the bulk of commercially available polyurethane samples, obtained from dissimilar- mixture ratios with different densities and branching levels as well as from different zones of the production mould. The characterisation allowed an estimation of the different dense materials - as they are used, e.g., in soles of shoes - as well as the invisible defects like pores and cracks, responsible for the materials fracture by mechanical loading. The obtained information are expected to be useful for various industrial sectors such as automotive and footwear industry. It will be completed by applying SANS, which has already proved to characterize the microstructure of the bulk-polymer with respect to nano-pores, micro-cracks and their arrangement in the polymer matrix. (paper)

  8. Three-dimensional visualization and measurement of water distributions in PEFC by dynamic CT method on neutron radiography

    International Nuclear Information System (INIS)

    Hashimoto, Michinori; Murakawa, Hideki; Sugimoto, Katsumi; Asano, Hitoshi; Takenaka, Nobuyuki; Mochiki, Koh-ichi

    2011-01-01

    Visualization of dynamic three-dimensional water behavior in a PEFC stack was carried out by neutron CT for clarifying water effects on performances of a Polymer Electrolyte Fuel Cell (PEFC) stack. Neutron radiography system at JRR-3 in Japan Atomic Energy Agency was used. An operating stack with three cells based on Japan Automobile Research Institute standard was visualized. A consecutive CT reconstruction method by rotating the fuel stack continuously was developed by using a neutron image intensifier and a C-MOS high speed video camera. The dynamic water behavior in channels in the operating PEFC stack was clearly visualized 15 sec in interval by the developed dynamic neutron CT system. From the CT reconstructed images, evaluation of water amount in each cell was carried out. It was shown that the water distribution in each cell was correlated well with power generation characteristics in each cell. (author)

  9. Application of thermal neutron radiography for the mass transport of moisture through freezing soil

    International Nuclear Information System (INIS)

    Clark, M.A.

    1989-04-01

    This thesis reports on the development of a technique to evaluate hydraulic conductivities in a soil (Snowcal) subject to freezing conditions. The technique draws on three distinctly different disciplines, Nuclear Physics, Soil Physics and Remote Sensing to provide a non-destructive and reliable evaluation of hydraulic conductivity throughout a freezing test. Thermal neutron radiography is used to provide information on local water/ice contents at anytime throughout the test. The experimental test rig is designed so that the soil matrix can be radiated by a neutron beam, from a nuclear reactor, to obtain radiographs. The radiographs can then be interpreted, following a process of remote sensing image enhancement, to yield information on relative water/ice contents. Interpretation of the radiographs is accommodated using image analysis equipment capable of distinguishing between 256 shades of grey. Remote sensing image enhancing techniques are then employed to develop false colour images which show the movement of water and development of ice lenses in the soil. Instrumentation is incorporated in the soil in the form of psychrometer/thermocouples, to record water potential, electrical resistance probes to enable ice and water to be differentiated on the radiographs and thermocouples to record the temperature gradient. Water content determinations are made from the enhanced images and plotted against potential measurements to provide the moisture characteristic for the soil. With relevant mathematical theory pore water distributions are obtained and combined with water content data to give hydraulic conductivities. The values for hydraulic conductivity in the saturated soil and at the frozen fringe are compared with established values for silts and silty-sands. The values are in general agreement and, with refinement, this non-destructive technique could afford useful information on a whole range of soils. (author)

  10. Development of Data Acquisition and Control Software for Neutron Radiography Facility at Serpong, Indonesia

    International Nuclear Information System (INIS)

    Bharoto

    2013-01-01

    A system for data acquisition and control software for the neutron radiography facility at Serpong has been developed. The software was developed to replace the previously existing control software which was no longer used due to problems on its computer hardware. Visual Basic running under Microsoft Windows operating system was used in developing the new software. In the hardware side, the film grabber and the motor driver were replaced. In the new system, the film grabber which was used to capture the image in the old system is replaced with a programmable CCD camera. The motor driver which was used to control the camera in two directions has been replaced with a four-direction motor driver. The software is capable of displaying the images in a real time mode and record the images in the hard disk of a personal computer. To obtain optimal image quality, the software processes the captured images by performing temperature adjustment, camera exposure time adjustment, and integration of the captured image in a certain frame numbers. The software is capable of taking a number of snapshots at a certain time interval. For neutron tomography purposes, the software takes the snapshots automatically at a sample position in line with the stepping movement of the rotating sample table. The snapshots were saved in a picture format and a numeric format for further processing. The software has been successfully tested for real time method and tomography reconstruction. The data captured by using this software has been verified using both commercial and in-house computed tomography software. (author)

  11. Evaluation of water behavior between aggregate and cement paste matrix by neutron radiography

    International Nuclear Information System (INIS)

    Maruyama, Ippei; Kanematsu, Manabu; Teramoto, Atsushi; Hayano, Hiroyuki; Iikura, Hiroshi; Noguchi, Takafumi

    2009-01-01

    The purpose of this study is to evaluate a water-supplied area from the saturated lightweight aggregate in high strength concrete. For this objective, phenomena of water transfer between cement paste, whose water to cement ratio is 0.25, and aggregates is visualized by neutron radiography technique. The parameter of this test was the type of aggregates, namely saturated lightweight aggregate, air dried lightweight aggregate, and ordinary sandstone. Additionally the steel is also tested for understanding the 'wall-effect'. Experimental results show that water supply from saturated lightweight aggregate continued upto more than 14days, and the water supplied area of cement paste was ranged within 4mm from the aggregate surface, and air dried lightweight aggregate suck the water from cement paste upto 12 hours and that water was released after 24 hours. Reduction of water content in cement paste, which was seen in both the test with steel and ordinary sandstone, was ranged within 1.2 mm from the surface. (author)

  12. Evaluation of water transfer from saturated lightweight aggregate to cement paste matrix by neutron radiography

    International Nuclear Information System (INIS)

    Maruyama, I.; Kanematsu, M.; Noguchi, T.; Iikura, H.; Teramoto, A.; Hayano, H.

    2009-01-01

    In high-strength concrete with low water-cement ratio, self-desiccation occurs due to cement hydration and causes shrinkage and an increased risk of cracking. While high-strength concrete has a denser matrix than normal-strength concrete, resulting in lower permeability, early-age cracks would cancel out this advantage. For the mitigation of this self-desiccation and resultant shrinkage, water-saturated porous aggregate, such as artificial lightweight aggregate, may be used in high-strength concrete. In this contribution, for the purpose of clarification of the volume change of high-strength concrete containing water-saturated lightweight aggregate, water transfer from the lightweight aggregate to cement paste matrix is visualized by neutron radiography. As a result, it is clear that water was supplied to the cement paste matrix in the range 3-8 mm from the surface of the aggregate, and the osmotic forces may yield water transfer around lightweight aggregate in a few hours after mixing.

  13. Void Fraction Measurement in Subcooled-Boiling Flow Using High-Frame-Rate Neutron Radiography

    International Nuclear Information System (INIS)

    Kureta, Masatoshi; Akimoto, Hajime; Hibiki, Takashi; Mishima, Kaichiro

    2001-01-01

    A high-frame-rate neutron radiography (NR) technique was applied to measure the void fraction distribution in forced-convective subcooled-boiling flow. The focus was experimental technique and error estimation of the high-frame-rate NR. The results of void fraction measurement in the boiling flow were described. Measurement errors on instantaneous and time-averaged void fractions were evaluated experimentally and analytically. Measurement errors were within 18 and 2% for instantaneous void fraction (measurement time is 0.89 ms), and time-averaged void fraction, respectively. The void fraction distribution of subcooled boiling was measured using atmospheric-pressure water in rectangular channels with channel width 30 mm, heated length 100 mm, channel gap 3 and 5 mm, inlet water subcooling from 10 to 30 K, and mass velocity ranging from 240 to 2000 kg/(m 2 .s). One side of the channel was heated homogeneously. Instantaneous void fraction and time-averaged void fraction distribution were measured parametrically. The effects of flow parameters on void fraction were investigated

  14. Visualization study on hot particle-water interaction by using neutron radiography

    International Nuclear Information System (INIS)

    Mishima, K.; Hibiki, T.; Saito, Y.; Moriyama, Kiyofumi; Sugimoto, Jun

    1999-01-01

    In relation to severe accident research of a nuclear reactor, an experiment was performed to simulate the premixing process in the vapor explosion by dropping hot stainless-steel particle into heavy water filled in a rectangular tank. The test rig consisted of a furnace and a rectangular tank (400 mm in height, 100 mm in width and 30 mm in depth) filled with heavy water kept at 4degC. The particle diameter used in the experiment were 6, 9 and 12 mm, and the initial temperature of the particle ranged from 600 to 1000degC. The behavior of gas dome generated by heated particle-subcooled water interaction was successfully visualized by high-frame-rate neutron radiography at the recording speed of 500 frames/s. Temporal and spatial variations of void fraction in the gas dome were measured by processing the images obtained. The void fraction measurement indicated the possibility that the ambient fluid was superheated by the hot particle-water contact and the vapor was generated in proportion to the particle size and temperature. Preliminary calculations of heat transfer from hot particle to water were conducted by using and empirical correlation for steady film boiling. Comparison between experimental and calculated results suggested that the transient heat transfer around the hot particle could not be explained only by steady film boiling but some other heat transfer mechanisms such as unsteady film boiling or hear transfer due to direct contact may be needed. (author)

  15. Nondestructive characterization of mixed oxide pellets in welded nuclear fuel pins by neutron radiography and gamma-autoradiography

    International Nuclear Information System (INIS)

    Panakkal, J.P.; Ghosh, J.K.; Roy, P.R.

    1989-01-01

    Nondestructive evaluation of nuclear fuel pellets after the welding of fuel pins plays a vital role in assuring a safe and reliable operation of reactors. Some of the important characteristics to be monitored in low plutonium enriched mixed oxide fuel pellets are plutonium enrichment, size of plutonium dioxide agglomerates, incorrect loading and geometric shape. Experiments were carried out at Bhabha Atomic Research Centre, Bombay on experimental fuel pins containing mixed oxide pellets of different geometry (solid and annular), of different plutonium enrichment (0-6 w% of plutonium dioxide) and containing PuO 2 agglomerates of size 125-2000 microns to evaluate these characteristics nondestructively. Neutron radiography of these fuel pins was carried out using a swimming pool type reactor 'APSARA'. Results of quantitative evaluation of the neutron radiographs and a simple model correlating neutron interaction probability and the optical density are presented. Gamma autoradiography of these fuel pins showed that these parameters could be evaluated with a few limitations. This paper presents the experimental details, quantitative analysis of the radiographs by microdensitometry and merits and demerits of neutron radiography and gamma autoradiography for nondestructive charcterisation of nuclear fuel pellets. (orig.)

  16. Quantitative imaging of water flow in soil and roots using neutron radiography and deuterated water

    Energy Technology Data Exchange (ETDEWEB)

    Zarebanadkouki, Mohsen

    2013-05-08

    Where and how fast do roots take up water? Despite its importance in plant and soil sciences, there is limited experimental information on the location of water uptake along the roots of transpiring plants growing in soil. The answer to this question requires direct and in-situ measurement of the local flow of water into the roots. The aim of this study was to develop and apply a new method to quantify the local fluxes of water into different segments of the roots of intact plants. To this end, neutron radiography was used to trace the transport of deuterated water (D{sub 2}O) into the roots of lupines. Lupines were grown in aluminum containers filled with sandy soil. The soil was partitioned into different compartments using 1 cm-thick layers of coarse sand as capillary barriers. These barriers limited the diffusion of D{sub 2}O within the soil compartments. D{sub 2}O was locally injected into the selected soil compartments during the day (transpiring plants) and night (non-transpiring plants). Transport of D{sub 2}O into roots was then monitored by neutron radiography with spatial resolution of 100 μm and time intervals of 10 seconds. Neutron radiographs showed that: i) transport of D{sub 2}O into roots was faster during the day than during the night; 2) D{sub 2}O quickly moved along the roots towards the shoots during the day, while at night this axial transport was negligible. The differences between day and night measurements were explained by convective transport of D{sub 2}O into the roots. To quantify the net flow of water into roots, a simple convection-diffusion model was developed, where the increase rate of D{sub 2}O concentration in roots depended on the convective transport (net root water uptake) and the diffusion of D{sub 2}O into roots. The results showed that water uptake was not uniform along the roots. Water uptake was higher in the upper soil layers than in the deeper ones. Along an individual roots, the water uptake rate was higher in the

  17. Quantitative imaging of water flow in soil and roots using neutron radiography and deuterated water

    International Nuclear Information System (INIS)

    Zarebanadkouki, Mohsen

    2013-01-01

    Where and how fast do roots take up water? Despite its importance in plant and soil sciences, there is limited experimental information on the location of water uptake along the roots of transpiring plants growing in soil. The answer to this question requires direct and in-situ measurement of the local flow of water into the roots. The aim of this study was to develop and apply a new method to quantify the local fluxes of water into different segments of the roots of intact plants. To this end, neutron radiography was used to trace the transport of deuterated water (D 2 O) into the roots of lupines. Lupines were grown in aluminum containers filled with sandy soil. The soil was partitioned into different compartments using 1 cm-thick layers of coarse sand as capillary barriers. These barriers limited the diffusion of D 2 O within the soil compartments. D 2 O was locally injected into the selected soil compartments during the day (transpiring plants) and night (non-transpiring plants). Transport of D 2 O into roots was then monitored by neutron radiography with spatial resolution of 100 μm and time intervals of 10 seconds. Neutron radiographs showed that: i) transport of D 2 O into roots was faster during the day than during the night; 2) D 2 O quickly moved along the roots towards the shoots during the day, while at night this axial transport was negligible. The differences between day and night measurements were explained by convective transport of D 2 O into the roots. To quantify the net flow of water into roots, a simple convection-diffusion model was developed, where the increase rate of D 2 O concentration in roots depended on the convective transport (net root water uptake) and the diffusion of D 2 O into roots. The results showed that water uptake was not uniform along the roots. Water uptake was higher in the upper soil layers than in the deeper ones. Along an individual roots, the water uptake rate was higher in the proximal segments than in the distal

  18. Optimization and comprehensive characterization of metal hydride based hydrogen storage systems using in-situ Neutron Radiography

    Science.gov (United States)

    Börries, S.; Metz, O.; Pranzas, P. K.; Bellosta von Colbe, J. M.; Bücherl, T.; Dornheim, M.; Klassen, T.; Schreyer, A.

    2016-10-01

    For the storage of hydrogen, complex metal hydrides are considered as highly promising with respect to capacity, reversibility and safety. The optimization of corresponding storage tanks demands a precise and time-resolved investigation of the hydrogen distribution in scaled-up metal hydride beds. In this study it is shown that in situ fission Neutron Radiography provides unique insights into the spatial distribution of hydrogen even for scaled-up compacts and therewith enables a direct study of hydrogen storage tanks. A technique is introduced for the precise quantification of both time-resolved data and a priori material distribution, allowing inter alia for an optimization of compacts manufacturing process. For the first time, several macroscopic fields are combined which elucidates the great potential of Neutron Imaging for investigations of metal hydrides by going further than solely 'imaging' the system: A combination of in-situ Neutron Radiography, IR-Thermography and thermodynamic quantities can reveal the interdependency of different driving forces for a scaled-up sodium alanate pellet by means of a multi-correlation analysis. A decisive and time-resolved, complex influence of material packing density is derived. The results of this study enable a variety of new investigation possibilities that provide essential information on the optimization of future hydrogen storage tanks.

  19. Assessment of the uncertainty and the proficiency test for accrediting KOLAS of ISO 17025 for a neutron radiography facility

    International Nuclear Information System (INIS)

    Oh, H.; Sim, C.M.; Lim, I.C.; Hong, K.P.; Choi, B.H.

    2004-01-01

    KOLAS(Korea of Lab Accreditation Scheme) is the charter member of ILAS (International Lab Accreditation Scheme) and APLAS (Asia Pacific Lab Accreditation Scheme), which originates from ISO 17025. KATS (Korea Agent of Technology Standard) governs the KOLAS. The KOLAS describes the basis of satisfying those issues related to a quality assurance and management system. The requirements specify an organization, the accommodation and environmental conditions, an uncertainty in the measurement and an inter-laboratory comparison or proficiency test program. The evaluation process of the requirements of certifying KOLAS for HANARO NRF has been proceeded by a neutron radiography laboratory, NRT level II course of SNT-TC-1A II is opened, with 20 persons attending for certification. An inter-laboratory comparison or proficiency test program is conducted through with Kyoto University in accordance with ASTM method for determining the imaging quality in direct thermal neutron radiographic testing (E545-91). In order to determine the uncertainty, dimensional measurements for the calibration fuel pin of the RISO using a profile project is performed with the ASTM practice for thermal neutron radiography of materials (E748-95) (orig.)

  20. Micromachining of commodity plastics by proton beam writing and fabrication of spatial resolution test-chart for neutron radiography

    International Nuclear Information System (INIS)

    Sakai, T.; Yasuda, R.; Iikura, H.; Nojima, T.; Matsubayashi, M.; Kada, W.; Kohka, M.; Satoh, T.; Ohkubo, T.; Ishii, Y.; Takano, K.

    2013-01-01

    Proton beam writing is a direct-write technique and a promising method for the micromachining of commodity plastics such as acrylic resins. Herein, we describe the fabrication of microscopic devices made from a relatively thick (∼75 μm) acrylic sheet using proton beam writing. In addition, a software package that converts image pixels into coordinates data was developed, and the successful fabrication of a very fine jigsaw puzzle was achieved. The size of the jigsaw puzzle pieces was 50 × 50 μm. For practical use, a prototype of a line and space test-chart was also successfully fabricated for the determination of spatial resolution in neutron radiography

  1. Use and imaging performance of CMOS flat panel imager with LiF/ZnS(Ag) and Gadox scintillation screens for neutron radiography

    Science.gov (United States)

    Cha, B. K.; kim, J. Y.; Kim, T. J.; Sim, C.; Cho, G.; Lee, D. H.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2011-01-01

    In digital neutron radiography system, a thermal neutron imaging detector based on neutron-sensitive scintillating screens with CMOS(complementary metal oxide semiconductor) flat panel imager is introduced for non-destructive testing (NDT) application. Recently, large area CMOS APS (active-pixel sensor) in conjunction with scintillation films has been widely used in many digital X-ray imaging applications. Instead of typical imaging detectors such as image plates, cooled-CCD cameras and amorphous silicon flat panel detectors in combination with scintillation screens, we tried to apply a scintillator-based CMOS APS to neutron imaging detection systems for high resolution neutron radiography. In this work, two major Gd2O2S:Tb and 6LiF/ZnS:Ag scintillation screens with various thickness were fabricated by a screen printing method. These neutron converter screens consist of a dispersion of Gd2O2S:Tb and 6LiF/ZnS:Ag scintillating particles in acrylic binder. These scintillating screens coupled-CMOS flat panel imager with 25x50mm2 active area and 48μm pixel pitch was used for neutron radiography. Thermal neutron flux with 6x106n/cm2/s was utilized at the NRF facility of HANARO in KAERI. The neutron imaging characterization of the used detector was investigated in terms of relative light output, linearity and spatial resolution in detail. The experimental results of scintillating screen-based CMOS flat panel detectors demonstrate possibility of high sensitive and high spatial resolution imaging in neutron radiography system.

  2. Identification of water storage tissue in the stem of cowpea plant (Vigna unguliculata Walp) by neutron radiography

    International Nuclear Information System (INIS)

    Nakanishi, T.M.; Don-Jin, K.; Ishii, R.; Matsubayashi, M.

    1999-01-01

    Cowpea (Vigna unguliculata Walp) is considered one of the most drought resistant species among the pulse crops. It was suggested that in the lower part of the stem, parenchymatous tissue for storing water has been developed for the function of drought resistance. However, such tissue has not been identified yet. In order to identify the water storing tissue in the stem of cowpea plant, the authors performed neutron radiography, which provides a non-destructive image of water distribution pattern in a plant. Common bean plant and soybean plant were used as references. Comparing the neutron radiograph for the stems of the plants, i.e., cowpea, common bean and soybean plants, the parenchymatous tissue with water storing function was distinguished in the intermode between primary leaf and the first trifoliate leaf specifically in cowpea plant. (author)

  3. Scattering influences in quantitative fission neutron radiography for the in situ analysis of hydrogen distribution in metal hydrides

    Energy Technology Data Exchange (ETDEWEB)

    Börries, S., E-mail: stefan.boerries@hzg.de [Helmholtz-Zentrum Geesthacht, Centre for Materials and Coastal Research, Max-Planck-Strasse 1, D-21502 Geesthacht (Germany); Metz, O.; Pranzas, P.K. [Helmholtz-Zentrum Geesthacht, Centre for Materials and Coastal Research, Max-Planck-Strasse 1, D-21502 Geesthacht (Germany); Bücherl, T. [ZTWB Radiochemie München (RCM), Technische Universität München (TUM), Walther-Meissner-Str. 3, D-85748 Garching (Germany); Söllradl, S. [Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRMII), Technische Universität München (TUM), Lichtenbergstr. 1, D-85748 Garching (Germany); Dornheim, M.; Klassen, T.; Schreyer, A. [Helmholtz-Zentrum Geesthacht, Centre for Materials and Coastal Research, Max-Planck-Strasse 1, D-21502 Geesthacht (Germany)

    2015-10-11

    In situ neutron radiography allows for the time-resolved study of hydrogen distribution in metal hydrides. However, for a precise quantitative investigation of a time-dependent hydrogen content within a host material, an exact knowledge of the corresponding attenuation coefficient is necessary. Additionally, the effect of scattering has to be considered as it is known to violate Beer's law, which is used to determine the amount of hydrogen from a measured intensity distribution. Within this study, we used a metal hydride inside two different hydrogen storage tanks as host systems, consisting of steel and aluminum. The neutron beam attenuation by hydrogen was investigated in these two different setups during the hydrogen absorption process. A linear correlation to the amount of absorbed hydrogen was found, allowing for a readily quantitative investigation. Further, an analysis of scattering contributions on the measured intensity distributions was performed and is described in detail.

  4. Using Neutron Radiography to Quantify Water Transport and the Degree of Saturation in Entrained Air Cement Based Mortar

    Science.gov (United States)

    Lucero, Catherine L.; Bentz, Dale P.; Hussey, Daniel S.; Jacobson, David L.; Weiss, W. Jason

    Air entrainment is commonly added to concrete to help in reducing the potential for freeze thaw damage. It is hypothesized that the entrained air voids remain unsaturated or partially saturated long after the smaller pores fill with water. Small gel and capillary pores in the cement matrix fill quickly on exposure to water, but larger pores (entrapped and entrained air voids) require longer times or other methods to achieve saturation. As such, it is important to quantitatively determine the water content and degree of saturation in air entrained cementitious materials. In order to further investigate properties of cement-based mortar, a model based on Beer's Law has been developed to interpret neutron radiographs. This model is a powerful tool for analyzing images acquired from neutron radiography. A mortar with a known volume of aggregate, water to cement ratio and degree of hydration can be imaged and the degree of saturation can be estimated.

  5. Moderator/collimator for a proton/deuteron linac to produce a high-intensity, high-quality thermal neutron beam for neutron radiography

    International Nuclear Information System (INIS)

    Singleterry, R.C. Jr.; Imel, G.R.; McMichael, G.E.

    1995-01-01

    Reactor based high resolution neutron radiography facilities are able to deliver a well-collimated (L/D ≥100) thermal flux of 10 6 n/cm 2 ·sec to an image plane. This is well in excess of that achievable with the present accelerator based systems such as sealed tube D-T sources, Van der Graaff's, small cyclotrons, or low duty factor linacs. However, continuous wave linacs can accelerate tens of milliamperes of protons to 2.5 to 4 MeV. The MCNP code has been used to analyze target/moderator configurations that could be used with Argonne's Continuous Wave Linac (ACWL). These analyses have shown that ACWL could be modified to generate a neutron beam that has a high intensity and is of high quality

  6. On progress of the solution of the stationary 2-dimensional neutron diffusion equation: a polynomial approximation method with error analysis

    International Nuclear Information System (INIS)

    Ceolin, C.; Schramm, M.; Bodmann, B.E.J.; Vilhena, M.T.

    2015-01-01

    Recently the stationary neutron diffusion equation in heterogeneous rectangular geometry was solved by the expansion of the scalar fluxes in polynomials in terms of the spatial variables (x; y), considering the two-group energy model. The focus of the present discussion consists in the study of an error analysis of the aforementioned solution. More specifically we show how the spatial subdomain segmentation is related to the degree of the polynomial and the Lipschitz constant. This relation allows to solve the 2-D neutron diffusion problem for second degree polynomials in each subdomain. This solution is exact at the knots where the Lipschitz cone is centered. Moreover, the solution has an analytical representation in each subdomain with supremum and infimum functions that shows the convergence of the solution. We illustrate the analysis with a selection of numerical case studies. (author)

  7. On progress of the solution of the stationary 2-dimensional neutron diffusion equation: a polynomial approximation method with error analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ceolin, C., E-mail: celina.ceolin@gmail.com [Universidade Federal de Santa Maria (UFSM), Frederico Westphalen, RS (Brazil). Centro de Educacao Superior Norte; Schramm, M.; Bodmann, B.E.J.; Vilhena, M.T., E-mail: celina.ceolin@gmail.com [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Programa de Pos-Graduacao em Engenharia Mecanica

    2015-07-01

    Recently the stationary neutron diffusion equation in heterogeneous rectangular geometry was solved by the expansion of the scalar fluxes in polynomials in terms of the spatial variables (x; y), considering the two-group energy model. The focus of the present discussion consists in the study of an error analysis of the aforementioned solution. More specifically we show how the spatial subdomain segmentation is related to the degree of the polynomial and the Lipschitz constant. This relation allows to solve the 2-D neutron diffusion problem for second degree polynomials in each subdomain. This solution is exact at the knots where the Lipschitz cone is centered. Moreover, the solution has an analytical representation in each subdomain with supremum and infimum functions that shows the convergence of the solution. We illustrate the analysis with a selection of numerical case studies. (author)

  8. Availability of MCNP and MATLAB for reconstructing the water-vapor two-phase flow pattern in neutron radiography

    International Nuclear Information System (INIS)

    Feng Qixi; Feng Quanke; Takeshi, K.

    2008-01-01

    The China Advanced Research Reactor (CARR) is scheduled to be operated in the autumn of 2008. In this paper, we report preparations for installing the neutron radiography instrument (NRI) and for utilizing it efficiently. The 2-D relative neutron intensity profiles for the water-vapor two-phase flow inside the tube were obtained using the MCNP code without influence of γ-ray and electronic-noise. The MCNP simulation of the 2-D neutron intensity profile for the water-vapor two-phase flow was demonstrated. The simulated 2-D neutron intensity profiles could be used as the benchmark data base by calibrating part of the data measured by the CARR-NRI. The 3-D objective images allow us to understand the flow pattern more clearly and it is reconstructed using the MATLAB through the threshold transformation techniques. And thus it is concluded that the MCNP code and the MATLAB are very useful for constructing the benchmark data base for the investigation of the water-vapor two-phase flow using the CARR-NRI. (authors)

  9. Qualitative discussion of quantitative radiography

    International Nuclear Information System (INIS)

    Berger, H.; Motz, J.W.

    1975-01-01

    Since radiography yields an image that can be easily related to the tested object, it is superior to many nondestructive testing techniques in revealing the size, shape, and location of certain types of discontinuities. The discussion is limited to a description of the radiographic process, examination of some of the quantitative aspects of radiography, and an outline of some of the new ideas emerging in radiography. The advantages of monoenergetic x-ray radiography and neutron radiography are noted

  10. Two-dimensional Haar wavelet Collocation Method for the solution of Stationary Neutron Transport Equation in a homogeneous isotropic medium

    International Nuclear Information System (INIS)

    Patra, A.; Saha Ray, S.

    2014-01-01

    Highlights: • A stationary transport equation has been solved using the technique of Haar wavelet Collocation Method. • This paper intends to provide the great utility of Haar wavelets to nuclear science problem. • In the present paper, two-dimensional Haar wavelets are applied. • The proposed method is mathematically very simple, easy and fast. - Abstract: This paper emphasizes on finding the solution for a stationary transport equation using the technique of Haar wavelet Collocation Method (HWCM). Haar wavelet Collocation Method is efficient and powerful in solving wide class of linear and nonlinear differential equations. Recently Haar wavelet transform has gained the reputation of being a very effective tool for many practical applications. This paper intends to provide the great utility of Haar wavelets to nuclear science problem. In the present paper, two-dimensional Haar wavelets are applied for solution of the stationary Neutron Transport Equation in homogeneous isotropic medium. The proposed method is mathematically very simple, easy and fast. To demonstrate about the efficiency of the method, one test problem is discussed. It can be observed from the computational simulation that the numerical approximate solution is much closer to the exact solution

  11. Specific radiography technique

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Beside radiography testing using x-ray machine and gamma source, there are several technique that developed specifically to complete the testing that cannot be done with the two earlier. This technique was specific based on several factor, for the example, the advantages of neutron and electron using to show the image was unique compare to x-ray and gamma. Besides that, these special radiography techniques maybe differ in how to detect the radiation get through the object. These technique can used to inspect thin or specimen that contained radioactive material. There are several technique will discussed in this chapter such as neutron radiography, electron radiography, fluoroscopy and also autoradiography.

  12. Imaging of fast-neutron sources using solid-state track-recorder pinhole radiography

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Gold, R.; Roberts, J.H.; Kaiser, B.J.; Preston, C.C.

    1983-08-01

    Pinhole imaging methods are being developed and tested for potential future use in imaging the intense neutron source of the Fusion Materials Irradiation Test (FMIT) Facility. Previously reported, extensive calibration measurements of the proton, neutron, and alpha particle response characteristics of CR-39 polymer solid state track recorders (SSTRs) are being used to interpret the results of imaging experiments using both charged particle and neutron pinhole collimators. High resolution, neutron pinhole images of a 252 Cf source have been obtained in the form of neutron induced proton recoil tracks in CR-39 polymer SSTR. These imaging experiments are described as well as their potential future applications to FMIT

  13. Design of neutron radiography facility in pool for the reactor RA-10

    International Nuclear Information System (INIS)

    Peirone, M.; Coleff, A.; Sanchez, F.; Chiaraviglio, N.

    2013-01-01

    RA-10 project consists in the design and construction of a multipurpose reactor for multiple applications, including radioisotopes production, material testing and an in pool facility for neutron imaging. Neutron imaging is a powerful tool for studies of materials and offer several advantages among other attenuation-based techniques. In this study mechanical and neutronic requirements for the RA-10 in pool neutron imaging facility are described. The MCNP neutronic model and the mechanical design satisfying these requirements in a first engineering stage are described. (author)

  14. Overview of the Neutron Radiography and Computed Tomography at the Oak Ridge National Laboratory and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Bilheux, Hassina Z [ORNL; Bilheux, Jean-Christophe [ORNL; Tremsin, Anton S [University of California, Berkeley; Santodonato, Louis J [ORNL; Dehoff, Ryan R [ORNL; Kirka, Michael M [ORNL; Bailey, William Barton [ORNL; Keener, Wylie S [ORNL; Herwig, Kenneth W [ORNL

    2015-01-01

    The Oak Ridge National Laboratory (ORNL) Neutron Sciences Directorate (NScD) has installed a neutron imaging (NI) beam line at the High Flux Isotope Reactor (HFIR) cold guide hall. The CG-1D beam line produces cold neutrons for a broad range of user research spanning from engineering to material research, additive manufacturing, vehicle technologies, archaeology, biology, and plant physiology. Recent efforts have focused on increasing flux and spatial resolution. A series of selected engineering applications is presented here. Historically and for more than four decades, neutron imaging (NI) facilities have been installed exclusively at continuous (i.e. reactor-based) neutron sources rather than at pulsed sources. This is mainly due to (1) the limited number of accelerator-based facilities and therefore the fierce competition for beam lines with neutron scattering instruments, (2) the limited flux available at accelerator-based neutron sources and finally, (3) the lack of high efficiency imaging detector technology capable of time-stamping pulsed neutrons with sufficient time resolution. Recently completed high flux pulsed proton-driven neutron sources such as the ORNL Spallation Neutron Source (SNS) at ORNL and the Japanese Spallation Neutron Source (JSNS) of the Japan Proton Accelerator Research Complex (J-PARC) in Japan produce high neutron fluxes that offer new and unique opportunities for NI techniques. Pulsed-based neutron imaging facilities RADEN and IMAT are currently being built at J-PARC and the Rutherford National Laboratory in the U.K., respectively. ORNL is building a pulsed neutron imaging beam line called VENUS to respond to the U.S. based scientific community. A team composed of engineers, scientists and designers has developed a conceptual design of the future VENUS imaging instrument at the SNS.

  15. A study of the distribution and uptake of boron in mango fruits using neutron-capture-radiography

    International Nuclear Information System (INIS)

    Loria, G.; Jimenez, R.; Gallardo, M.; Martini, F.; Thellier, M.

    1992-01-01

    The method of neutron-capture-radiography (NCR) was used to study the distribution of boron in mango fruit. There was a regular decrease of the concentration of natural boron from the skin (83.9 ppm, dry weight) to the interior of the fruit (2.4 ppm, dry weight, 5.6 mm deep in the fruit). When drops of a solution of ( 10 B)BO 3 H 3 were placed on the fruit surface, boron accumulated in restricted zones, within the fruit skin, which apparently corresponded to skin secretory-glands. The apparent coefficient of diffusion of boric acid from these zones of high boron accumulation to the interior of the fruit was of the order of 1.6 x 10 -12 m 2 s -1

  16. Neutron radiography for visualization of liquid metal processes: bubbly flow for CO2 free production of Hydrogen and solidification processes in EM field

    Science.gov (United States)

    Baake, E.; Fehling, T.; Musaeva, D.; Steinberg, T.

    2017-07-01

    The paper describes the results of two experimental investigations aimed to extend the abilities of a neutron radiography to visualize two-phase processes in the electromagnetically (EM) driven melt flow. In the first experiment the Argon bubbly flow in the molten Gallium - a simulation of the CO2 free production of Hydrogen process - was investigated and visualized. Abilities of EM stirring for control on the bubbles residence time in the melt were tested. The second experiment was directed to visualization of a solidification front formation under the influence of EM field. On the basis of the neutron shadow pictures the form of growing ingot, influenced by turbulent flows, was considered. In the both cases rotating permanent magnets were agitating the melt flow. The experimental results have shown that the neutron radiography can be successfully employed for obtaining the visual information about the described processes.

  17. Development of a dynamic CT system for neutron radiography and consecutive visualization of three-dimensional water behavior in a PEFC stack

    International Nuclear Information System (INIS)

    Murakawa, Hideki; Hashimoto, Michinori; Sugimoto, Katsumi; Asano, Hitoshi; Takenaka, Nobuyuki; Mochiki, Koh-ichi; Yasuda, Ryo

    2011-01-01

    A dynamic CT system was developed for visualization of consecutive three-dimensional water behavior in a PEFC stack for neutron radiography. The system is composed of a neutron image intensifier and a C-MOS high speed video camera. An operating stack with three cells based on the Japan Automobile Research Institute standard was visualized using the neutron radiography system at a research reactor JRR-3 in Japan Atomic Energy Agency. The dynamic water behavior in channels in the operating PEFC stack was clearly visualized every 15 seconds by using the system. The water amount in each cell was evaluated by the CT reconstructed images. It was shown that a cell voltage decreased gradually when the water increased and increased rapidly when the water was evacuated. It was estimated that the power generation stopped when the channel of a cell was partly filled with the water because the air supply was blocked to a cell in the stack. (author)

  18. Comparison of polystyrene scintillator fiber array and monolithic polystyrene for neutron imaging and radiography

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, R., E-mail: raspberry@lanl.gov; Cutler, T. E.; Danly, C. R.; Espy, M. A.; Goglio, J. H.; Hunter, J. F.; Madden, A. C.; Mayo, D. R.; Merrill, F. E.; Nelson, R. O.; Swift, A. L.; Wilde, C. H.; Zocco, T. G. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2016-11-15

    The neutron imaging diagnostic at the National Ignition Facility has been operating since 2011 generating neutron images of deuterium-tritium (DT) implosions at peak compression. The current design features a scintillating fiber array, which allows for high imaging resolution to discern small-scale structure within the implosion. In recent years, it has become clear that additional neutron imaging systems need to be constructed in order to provide 3D reconstructions of the DT source and these additional views need to be on a shorter line of sight. As a result, there has been increased effort to identify new image collection techniques that improve upon imaging resolution for these next generation neutron imaging systems, such as monolithic deuterated scintillators. This work details measurements performed at the Weapons Neutron Research Facility at Los Alamos National Laboratory that compares the radiographic abilities of the fiber scintillator with a monolithic scintillator, which may be featured in a future short line of sight neutron imaging systems.

  19. Optimization of the Army’s Fast Neutron Moderator for Radiography

    Science.gov (United States)

    2013-02-26

    TECHNOLOGY DEVELOPMENTS 13 PNL Generator / Moderator Design 13 CONCLUSIONS 15 REFERENCES 16 LIST OF SYMBOLS, ABBREVIATIONS...and x-ray image 12 Figure 6: Second half comparison of neutron, processed, and x-ray image 13 Figure 7: The initial setup of the PNL neutron...reactor facility; for example, muntions and weapon systems that contain energetic materials. TECHNOLOGY DEVELOPMENTS: PNL Generator / Moderator

  20. Scanning of Cargo Containers by Gamma-Ray and Fast Neutron Radiography

    International Nuclear Information System (INIS)

    Yousri, A.M.; Bashter, I.I.; Megahid, M.R.; Osman, A.M.; Kansouh, W.A.; Reda, A.M.

    2011-01-01

    This paper describes the combined systems which were installed and tested to detect contraband smuggled in cargo containers. These combined systems are based on radiographers work by gamma-rays emitted from point source 60 Co with 0.5 Ci activity and neutrons emitted from point isotopic sources of Pu-α-Be as well as 14 MeV neutrons emitted from sealed tube neutron generator. The transmitted gamma ray through the inspected object was measured by gamma detection system with NaI(Tl) detector while the transmitted fast neutron beam was measured by a neutron gamma detection system with stilbene organic scintillator. The later possess the capability of discrimination between between gamma and neutron pulses using a discrimination system based on pulse shape discrimination method. The measured intensities of primary incident and transmitted beams of gamma-rays and fast neutrons were used to construct 2D cross-sectional images of the inspected objects hidden directly within benign materials of the container and for object screened by high dense material to stop object detection by gamma or X-rays. The constructed images for the inspected objects show the good capability and effectiveness of the installed gamma and neutron radiographers to detect illicit materials hidden in air cargo containers and sea containers of med size. They have also indicated that the developed scanning systems possess the ease of mobility and low cost of scanning

  1. Use of a Van de Graaff proton accelerator for neutron radiography

    International Nuclear Information System (INIS)

    Cassidy, J.P.

    1976-12-01

    A neutron radiographic capability has been established at the Pantex ERDA Plant. A 3 MeV Van de Graaff accelerator is being used to make neutron radiographs in order to observe defects of explosives encased in metal containers and ''O'' ring integrity

  2. System of image package input and output for neutron radiography based on PC IBM XT/AT; Sistema paketnogo vvoda i vyvoda izobrazhenij dlya nejtronnoj radiografii na baze PEhVM IBM PC XCT/AT

    Energy Technology Data Exchange (ETDEWEB)

    Avarzad, O; Rikhvitskij, V S

    1996-12-31

    System of acquisition and analysis of both statistic and dynamic images of neutron radiography includes NM IBM PC XT/AT, super vidicon, telecamera based video detector, color monitor and interface board of image input-output. 2 refs.

  3. Modelling of the non-stationary thermal neutron transport in hydrogenous media using the MCNP code

    International Nuclear Information System (INIS)

    Wiacek, Urszula

    2006-01-01

    The work is aimed to compare results of the Monte Carlo simulations of pulsed neutron experiments with results of real experiments. The simulations have been performed for homogenous and two-zone system. In the first case the cylinder of Plexiglas has been used. In two-zone systems, Plexiglas has been used as an outer moderator and aqueous solutions of H 3 BO 3 or KCl of known concentrations have been used as the inner samples. The simulations have been performed (1) using for neutron scattering in Plexiglas a standard library for H in polyethylene (a commonly suggested way) and (2) using a modification of this library. The modification gives very good agreement between simulations and experimental results

  4. Main effects of the Earth's rotation on the stationary states of ultra-cold neutrons

    International Nuclear Information System (INIS)

    Arminjon, Mayeul

    2008-01-01

    The relativistic corrections in the Hamiltonian for a particle in a uniformly rotating frame are discussed. They are shown to be negligible in the case of ultra-cold neutrons (UCN) in the Earth's gravity. The effect, on the energy levels of UCN, of the main term due to the Earth's rotation, i.e. the angular-momentum term, is calculated. The energy shift is found proportional to the energy level itself

  5. Neutron radiography applied to qualitative and quantitative non-destructive testing of metals and alloys

    International Nuclear Information System (INIS)

    Laporte, A.; Bayon, G.; Thierry, D.

    1981-01-01

    The radiation-material interaction between X-rays, gamma rays and neutrons is compared. The different possibilities of image detection are enumerated. The industrial testing installations associated with the Triton experimental reactor of the Fontenay-aux-Roses Nuclear Research Centre is described. A high performance testing unit is presented -the use of an intense flux of cold neutrons in a special building designed for neutrons radiographic testing- which will enter service in the second half of 1980, in association with the Orphee basic physics reactor of the Saclay Nuclear Research Centre. Concrete examples of manufacturing control on metal parts are given such as: testing of bonds between two metals of comparable density, testing of the homogeneity of high density alloys, testing of the homogeneity of low density alloys, testing of materials with high neutron contrast. Neutron radiographic testing not only achieves qualitative but also quantitative analysis of the films, on two levels, dimensional measurement and homogeneity and/or concentration measurement, by densitometry. Testing methods used for complete quantitative analysis of boronated aluminium plates used in the nuclear industry are examined. Perspectives concerning routine tests, by dealing with fundamental aspects of standardization and the knowledge of the phenomena involved in this testing technique are given [fr

  6. Quantitative neutron capture radiography for studying the biodistribution of tumor-seeking boron-containing compounds

    International Nuclear Information System (INIS)

    Gabel, D.; Holstein, H.; Larsson, B.; Gille, L.; Ericson, G.; Sacker, D.; Som, P.; Fairchild, R.G.

    1987-01-01

    Biodistribution of two compounds presently considered for use in neutron capture therapy has been studied in mice carrying a transplantable Harding-Passey melanoma. A method is described by which quantitative assessment can be made of the boron distribution in whole-body sections of such animals. An alpha-particle-sensitive film is placed in close contact with a freeze-dried section of an animal and exposed to neutrons. The tracks visible after etching are analyzed optoelectronically in fields of 0.6 X 0.6 mm2 and compared to standards of boron homogeneously distributed in liver homogenates. The dynamic range of this method is about two orders of magnitude in concentration, with a lower detection limit of 0.1 to 0.01 ppm 10 B, depending on the rate of induction of spurious tracks by fast neutrons present in the neutron beam chosen. In a transplantable Harding-Passey melanoma in mice, it was found that the sulfhydryl boron hydride Na2B12H11SH presently used for therapy of glioblastoma clears blood, muscle, and brain very rapidly. Its accumulation in tumors was persistent for more than three days. A higher tumor accumulation was observed with its disulfide, which has been suggested for neutron capture therapy. For both compounds, a marked heterogeneity of boron distribution within one tumor was found

  7. Design studies for a high-resolution, transportable neutron radiography/radioscopy system

    International Nuclear Information System (INIS)

    Gillespie, G.H.; Micklich, B.J.; McMichael, G.E.

    1996-01-01

    A preliminary design has been developed for a high-resolution, transportable neutron radiology system (TNRS) concept. The primary system requirement is taken to be a thermal neutron flux of 10[sup 6] n/(cm[sup 2]-sec) with a L/D ratio of 100. The approach is to use an accelerator-driven neutron source, with a radiofrequency quadrupole (RFQ) as the primary accelerator component. Initial concepts for all of the major components of the system have been developed,and selected key parts have been examined further. An overview of the system design is presented, together with brief summaries of the concepts for the ion source, low energy beam transport (LEBT), RFQ, high energy beam transport (HEBT), target, moderator, collimator, image collection, power, cooling, vacuum, structure, robotics, control system, data analysis, transport vehicle, and site support. The use of trade studies for optimizing the TNRS concept are also described

  8. An efficient and cost-effective microchannel plate detector for slow neutron radiography

    Science.gov (United States)

    Wiggins, B. B.; Vadas, J.; Bancroft, D.; deSouza, Z. O.; Huston, J.; Hudan, S.; Baxter, D. V.; deSouza, R. T.

    2018-05-01

    A novel approach for efficiently imaging objects with slow neutrons in two dimensions is realized. Neutron sensitivity is achieved by use of a boron doped microchannel plate (MCP). The resulting electron avalanche is further amplified with a Z-stack MCP before being sensed by two orthogonally oriented wire planes. Coupling of the wire planes to delay lines efficiently encodes the position information as a time difference. To determine the position resolution, slow neutrons were used to illuminate a Cd-mask placed directly in front of the detector. Peaks in the resulting spectrum exhibited an average peak width of 329 μm FWHM, corresponding to an average intrinsic resolution of 216 μm. The center region of the detector exhibits a significantly better spatial resolution with an intrinsic resolution of <100 μm observed.

  9. Gamma radiography and its technological application

    International Nuclear Information System (INIS)

    Courtois, G.

    1962-01-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  10. Applying thermal neutron radiography to non-destructive assays of dynamic systems

    International Nuclear Information System (INIS)

    Silvani, Maria I.; Almeida, Gevaldo L. de; Goncalves, Marcelo J.; Lopes, Ricardo T.

    2008-01-01

    Dynamic processes or systems frequently can not have their behavior directly analyzed due to safety reasons or because they require destructive assays, which can not be always afforded when high-cost equipment, devices and components are involved. Under these circumstances, some kind of non-destructive technique should be applied to preserve the safety of the personnel performing the assay, as well as the integrity of the piece being inspected. Thermal neutrons are specially suited as a tool for this purpose, thanks to their capability to pass through metallic materials, which could be utterly opaque to X-rays. This paper describes the accomplishments achieved at the Instituto de Engenharia Nuclear / CNEN, Brazil, aiming at the development of an Image Acquisition System capable to perform non-destructive assays using thermal neutrons. It is comprised of a thermal neutron source provided by the Argonauta research reactor, a converter-scintillating screen, and a CCD-based video camera optically coupled to the screen through a dark chamber equipped with a mirror. The developed system has been used to acquire 2D neutron radiographic images of static devices to reveal their inner structure, as well as movies of running systems and working devices to verify its functioning and soundness. Radiographic images of objects taken at different angles would be later on used as projections to retrieve - through a proper unfolding software - their 3D images expressed as attenuation coefficients for thermal neutrons. A quantitative performance of the system has been assessed through its Modulation Transfer Function - MTF. In order to determine this curve, unique collimators designed to simulate different spatial frequencies have been manufactured. Besides that, images of some objects have been acquired with the system being developed as well as using the conventional radiographic film, allowing thus a qualitative comparison between them. (author)

  11. Void fraction and velocity measurement of simulated bubble in a rotating disc using high frame rate neutron radiography.

    Science.gov (United States)

    Saito, Y; Mishima, K; Matsubayashi, M

    2004-10-01

    To evaluate measurement error of local void fraction and velocity field in a gas-molten metal two-phase flow by high-frame-rate neutron radiography, experiments using a rotating stainless-steel disc, which has several holes of various diameters and depths simulating gas bubbles, were performed. Measured instantaneous void fraction and velocity field of the simulated bubbles were compared with the calculated values based on the rotating speed, the diameter and the depth of the holes as parameters and the measurement error was evaluated. The rotating speed was varied from 0 to 350 rpm (tangential velocity of the simulated bubbles from 0 to 1.5 m/s). The effect of shutter speed of the imaging system on the measurement error was also investigated. It was revealed from the Lagrangian time-averaged void fraction profile that the measurement error of the instantaneous void fraction depends mainly on the light-decay characteristics of the fluorescent converter. The measurement error of the instantaneous local void fraction of simulated bubbles is estimated to be 20%. In the present imaging system, the light-decay characteristics of the fluorescent converter affect the measurement remarkably, and so should be taken into account in estimating the measurement error of the local void fraction profile.

  12. Visualization and measurement of liquid velocity field of gas-liquid metal two-phase flow using neutron radiography

    International Nuclear Information System (INIS)

    Saito, Yasushi; Suzuki, Tohru; Matsubayashi, Masahito

    2000-01-01

    In a core melt accident of a fast breeder reactor, a possibility of re-criticality is anticipated in the molten fuel-steel mixture pool. One of the mechanisms to suppress the re-criticality is the boiling of steel in the molten fuel-steel mixture pool because of the negative void reactivity effect. To evaluate the reactivity change due to boiling, it is necessary to know the characteristics of gas-liquid two-phase flow in the molten fuel-steel mixture pool. For this purpose, boiling bubbles in a molten fuel-steel mixture pool were simulated by adiabatic gas bubbles in a liquid metal pool to study the basic characteristics of gas-liquid metal two-phase mixture. Visualization of the two-phase mixture and measurements of liquid phase velocity and void fraction were conducted by using neutron radiography and image processing techniques. From these measurements, the basic characteristics of gas-liquid metal two-phase mixture were clarified. (author)

  13. Void fraction and velocity measurement of simulated bubble in a rotating disc using high frame rate neutron radiography

    International Nuclear Information System (INIS)

    Saito, Y.; Mishima, K.; Matsubayashi, M.

    2004-01-01

    To evaluate measurement error of local void fraction and velocity field in a gas-molten metal two-phase flow by high-frame-rate neutron radiography, experiments using a rotating stainless-steel disc, which has several holes of various diameters and depths simulating gas bubbles, were performed. Measured instantaneous void fraction and velocity field of the simulated bubbles were compared with the calculated values based on the rotating speed, the diameter and the depth of the holes as parameters and the measurement error was evaluated. The rotating speed was varied from 0 to 350 rpm (tangential velocity of the simulated bubbles from 0 to 1.5 m/s). The effect of shutter speed of the imaging system on the measurement error was also investigated. It was revealed from the Lagrangian time-averaged void fraction profile that the measurement error of the instantaneous void fraction depends mainly on the light-decay characteristics of the fluorescent converter. The measurement error of the instantaneous local void fraction of simulated bubbles is estimated to be 20%. In the present imaging system, the light-decay characteristics of the fluorescent converter affect the measurement remarkably, and so should be taken into account in estimating the measurement error of the local void fraction profile

  14. Retinue of the beans roots growth by using neutron radiography technique

    International Nuclear Information System (INIS)

    Jesus, Selma Parente de; Crispim, Verginia Reis

    2002-01-01

    Agricultural practices frequently cause the development of a soil compacted layer below the surface. These compacted layers restrict the root penetration into deeper layers of soil, in search for water. It is proposed to monitor, using Non Destructive Test, the roots growth due to the planting of standard seeds in different agricultural soils, in function of their compactness and humidity. It will be used the neutrons beams derived from an irradiation channel called J-9 of the Reactor Argonauta (IEN/CNEN), so that the neutron radiographic images of the soil-plant system can be obtained. Each root can be evaluated for its ability to penetrate into compacted soil layers; this fact would mean an optimization of agricultural harvests. (author)

  15. The use of the neutron radiography in the diagnosis of microorganisms contamination

    International Nuclear Information System (INIS)

    Wacha, Reinaldo; Crispim, Verginia R.; Lage, Claudia

    2000-01-01

    This work aims to present a new method of microorganism detection in several culture medium, such as potable water and corporal fluids. After the steps of processes of growth in culture medium, separation and resuspension in a boron based lid solution, the microorganisms are deposited in lines detectors and at last submitted to a thermal neutrons beam (≡ 2,2 x 10 5 n/cm 2 .s). The latent tracks registered by the alpha particles coming from the B(n,α)Li reaction are analyzed by an optical microscope, allowing the detection of microorganisms existence. (author)

  16. Review on use of neutron radiography at Saclay Nuclear Research Centre

    Energy Technology Data Exchange (ETDEWEB)

    Bayon, G [Saclay Nuclear Research Centre DRE/SRO, Gif-sur-Yvette (France)

    1996-11-01

    The Commissariat a l`Energie Atomique (CEA) operates three research reactors at Saclay. Each of them is equipped with a Neutron Radiology facility. Osiris is involved in studies of nuclear fuel rod behaviour during accidental events. The underwater NR facility allows to obtain images of the rods before and after power ramp. The Orphee installation is devoted to industrial application of NR including non destructive testing and real time imaging. The main activity concerns the examination of the pyrotechnic devices of the Ariane launcher programmes. Other areas of interest are also described. (author) 2 figs., 1 tab., 5 refs.

  17. Review on use of neutron radiography at Saclay Nuclear Research Centre

    International Nuclear Information System (INIS)

    Bayon, G.

    1996-01-01

    The Commissariat a l'Energie Atomique (CEA) operates three research reactors at Saclay. Each of them is equipped with a Neutron Radiology facility. Osiris is involved in studies of nuclear fuel rod behaviour during accidental events. The underwater NR facility allows to obtain images of the rods before and after power ramp. The Orphee installation is devoted to industrial application of NR including non destructive testing and real time imaging. The main activity concerns the examination of the pyrotechnic devices of the Ariane launcher programmes. Other areas of interest are also described. (author) 2 figs., 1 tab., 5 refs

  18. An investigation of the element composition of superconducting ceramics by neutron activation and radiography methods

    International Nuclear Information System (INIS)

    Kist, A.A.; Flitsiyan, E.S.

    1994-01-01

    The neutron activation methods for determining the general composition and distribution of the main components in HTSC ceramics were developed. The conditions for the reduction of the analysis error were discussed. The dependences of the oxygen content and superconducting parameters of single-phase and polyphase yttrium ceramics on the regime of heat treatment in air were investigated. Variation in the oxygen content was found to have a nonmonotone character, depending on the temperature of quenching and annealing. Correlation between the character of the superconducting transition and the oxygen content was observed. During the heat treatment, reversible structural phase transitions proceed in the single-phase ceramics in the polyphase ceramics, the recrystallization processes occur, which result in homogenization of its structure

  19. Visualization of root water uptake: quantification of deuterated water transport in roots using neutron radiography and numerical modeling.

    Science.gov (United States)

    Zarebanadkouki, Mohsen; Kroener, Eva; Kaestner, Anders; Carminati, Andrea

    2014-10-01

    Our understanding of soil and plant water relations is limited by the lack of experimental methods to measure water fluxes in soil and plants. Here, we describe a new method to noninvasively quantify water fluxes in roots. To this end, neutron radiography was used to trace the transport of deuterated water (D2O) into roots. The results showed that (1) the radial transport of D2O from soil to the roots depended similarly on diffusive and convective transport and (2) the axial transport of D2O along the root xylem was largely dominated by convection. To quantify the convective fluxes from the radiographs, we introduced a convection-diffusion model to simulate the D2O transport in roots. The model takes into account different pathways of water across the root tissue, the endodermis as a layer with distinct transport properties, and the axial transport of D2O in the xylem. The diffusion coefficients of the root tissues were inversely estimated by simulating the experiments at night under the assumption that the convective fluxes were negligible. Inverse modeling of the experiment at day gave the profile of water fluxes into the roots. For a 24-d-old lupine (Lupinus albus) grown in a soil with uniform water content, root water uptake was higher in the proximal parts of lateral roots and decreased toward the distal parts. The method allows the quantification of the root properties and the regions of root water uptake along the root systems. © 2014 American Society of Plant Biologists. All Rights Reserved.

  20. Recent developments in radiography

    International Nuclear Information System (INIS)

    Berger, Harold

    1982-01-01

    Advances in radiography are reviewed and eighty-one references are cited to provide additional information. The review includes information on x-ray sources in terms of output, portability and imaging geometry and detectors in terms of films and screens, electrostatic methods, real-time techniques and solid state devices. Inspection methods utilizing radiations other than x-rays, neutrons and charged particles, expand the inspection problems suitable for radiography. Techniques such as tomography, digital radiography and image enhancement are described. Tomography, in particular, provides excellent capability to characterize materials and discontinuities

  1. Characterization and adjustment of the neutron radiography facility of the RP-10 nuclear reactor; Caracterizacion y puesta a punto de la facilidad de neutrografia del reactor nuclear RP-10

    Energy Technology Data Exchange (ETDEWEB)

    Ravello R, Y R

    2001-07-01

    The main aim of this work was to characterize and adjust the neutron radiography facility of the RP-10 nuclear reactor, and therefore be able to offer with this technique services to the industry and research centers in general. This technique will be complemented with others such as x-rays and gamma radiography. First, the shielding capacity of the facility was analyzed, proving that it complies with the radiological safety requirements established by the radiological safety code. Then gamma filtration tests were conducted in order to implement the direct method for image formation, optical density curves were built according to the thickness of the gamma filter, the type of film and the type of irradiation. Also, the indirect method for image formation was implemented for two types of converters: indium and dysprosium. Growth curves for optical density were also made according to contact time between converter-film, for different types of films. The resolution of the facility was also analyzed using two methods: Klasens (1946) and Harms (1986). Harms method came closer to the resolution of the human eye when compared to the Klasens method. Finally, the application fields of neutron radiography are presented, including those conducted at the neutron radiography facility of the RP-10 nuclear reactor. With this work, the RP-10 neutron radiography facility is ready to offer inspection and research services.

  2. Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system

    Energy Technology Data Exchange (ETDEWEB)

    Zboray, Robert [Paul Scherrer Institute, PSI Villigen 5232 (Switzerland); Dangendorf, Volker; Bromberger, Benjamin; Tittelmeier, Kai [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig 38116 (Germany); Mor, Ilan [Soreq NRC, Yavne 81800 (Israel)

    2015-07-15

    In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.

  3. Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system.

    Science.gov (United States)

    Zboray, Robert; Dangendorf, Volker; Mor, Ilan; Bromberger, Benjamin; Tittelmeier, Kai

    2015-07-01

    In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.

  4. Neutron radiography and X-ray computed tomography for quantifying weathering and water uptake processes inside porous limestone used as building material

    International Nuclear Information System (INIS)

    Dewanckele, J.; De Kock, T.; Fronteau, G.; Derluyn, H.; Vontobel, P.; Dierick, M.; Van Hoorebeke, L.; Jacobs, P.; Cnudde, V.

    2014-01-01

    Euville and Savonnières limestones were weathered by acid test and this resulted in the formation of a gypsum crust. In order to characterize the crystallization pattern and the evolution of the pore structure below the crust, a combination of high resolution X-ray computed tomography and SEM–EDS was used. A time lapse sequence of the changing pore structure in both stones was obtained and afterwards quantified by using image analysis. The difference in weathering of both stones by the same process could be explained by the underlying microstructure and texture. Because water and moisture play a crucial role in the weathering processes, water uptake in weathered and non-weathered samples was characterized based on neutron radiography. In this way the water uptake was both visualized and quantified in function of the height of the sample and in function of time. In general, the formation of a gypsum crust on limestone slows down the initial water uptake in the materials. - Highlights: • Time lapse sequence in 3D of changing pore structures inside limestone • A combination of X-ray CT, SEM and neutron radiography was used. • Quantification of water content in function of time, height and weathering • Characterization of weathering processes due to gypsum crystallization

  5. The use of neutron radiography and microdensitometry in the study of instrumental effectiveness on dental tissue in the process of mineralization

    International Nuclear Information System (INIS)

    Vulcain, J.M.; Tamisier, J.; Espie, J.H.; Masse, R.; Laporte, A.

    1983-01-01

    In this study, neutron-radiography is used as a non-destructive method of exposing the peripheral part of the root canal which, in the course of endodontic treatment, is to be removed by root therapy instruments. Samples are treated with an agent of contrast with high screen power for neutrons: gadolinium which is used in the form of a citrate solution, it slowly diffuses through non-mineralized structures and settles like the other rare earths on the interface of mineralized tissues and of those in the process of mineralization, in this case, dentin and predentin. This mechanism is on occasion controlled by the richness of proteoglycans in this tissue. Once the samples are saturated, a neutron-radiographic image is made, then analyzed by microdensitometry so as to obtain a quantitative parameter. After instrumentation of the samples, a new neutron-radiographic image, and a new microdensitometric analysis are made. The results thus obtained make it possible to quantify the effectiveness of the various instruments available for endodontic treatments. (Auth.)

  6. Effect of non-stationary accretion on spectral state transitions: An example of a persistent neutron star LMXB 4U1636–536

    Science.gov (United States)

    Zhang, Hui; Yu, Wen-Fei

    2018-03-01

    Observations of black hole and neutron star X-ray binaries show that the luminosity of the hard-to-soft state transition is usually higher than that of the soft-to-hard state transition, indicating additional parameters other than mass accretion rate are required to interpret spectral state transitions. It has been found in some individual black hole or neutron star soft X-ray transients that the luminosity corresponding to the hard-to-soft state transition is positively correlated with the peak luminosity of the following soft state. In this work, we report the discovery of the same correlation in the single persistent neutron star low mass X-ray binary (LMXB) 4U 1636–536 based on data from the All Sky Monitor (ASM) on board RXTE, the Gas Slit Camera (GSC) on board MAXI and the Burst Alert Telescope (BAT) on board Swift. We also found such a positive correlation holds in this persistent neutron star LMXB in a luminosity range spanning about a factor of four. Our results indicate that non-stationary accretion also plays an important role in driving X-ray spectral state transitions in persistent accreting systems with small accretion flares, which is much less dramatic compared with the bright outbursts seen in many Galactic LMXB transients.

  7. Gamma radiography and its technological application; Gammagraphie et techniques annexes

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1962-07-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  8. Computer radiography - indirect digital radiography

    International Nuclear Information System (INIS)

    Jezierski, G.

    2008-01-01

    Implementation of the new European standards for industrial radiography with the use of storage phosphor imaging plates will result in the arousing of interest among numerous laboratories in non-destructive testing with application of the new method of testing to replace conventional radiography used so far, i.e. film radiography. Computer radiography is quite commonly used for medical radiography, where the fundamental problem consists in reduction of the radiation dose during the examination of a patient. However, it must be kept in mind that industrial applications have a little bit different requirements when compared with medical radiography. The article describes only new method for radiographic testing. (author)

  9. Neutron and high-contrast X-ray micro-radiography as complementary tools for monitoring organosilicon consolidants in natural building stones

    Energy Technology Data Exchange (ETDEWEB)

    Slavíková, Monika, E-mail: Monika.Slavikova@vscht.cz [Department of Chemical Technology of Monuments Conservation, Institute of Chemical Technology in Prague, Prague 6 CZ-16628 (Czech Republic); Krejčí, František [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Prague 2 CZ-12800 (Czech Republic); Kotlík, Petr [Department of Chemical Technology of Monuments Conservation, Institute of Chemical Technology in Prague, Prague 6 CZ-16628 (Czech Republic); Jakůbek, Jan [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Prague 2 CZ-12800 (Czech Republic); Tomandl, Ivo; Vacík, Jiří [Nuclear Physics Institute, Academy of Sciences of the Czech Republic, CZ-25800, Rez Near Prague (Czech Republic)

    2014-11-01

    The monitoring of consolidants and other treatment product in stones is currently of great importance in various restoration studies. We use neutron and high-contrast X-ray micro-radiography as complementary non-destructive techniques for monitoring of organosilicon consolidants in the Opuka stone. Thanks to different sensitivities of both techniques in relation to the elemental composition, the effect of addition of the contrast agent (3-iodopropyl)trimethoxysilane commonly used in stone consolidation monitoring with X-ray radiography is evaluated. As the addition of the contrast agent to the original consolidation product alters important parameters such as the penetration depth, the understanding of the behaviour of the modified consolidation mixture is essential for verification of the reliability of the method. By comparing results from both methods, the respective radiographs show consistency in terms of homogeneity and penetration depth for all investigated concentrations of the used contrast agent. The presented results further demonstrate that the application of the contrast agent apparently changes the penetration depth, but these changes are, especially for very low concentrations (up to 1%) for most of the studies needed, negligible.

  10. Real-time measurements of temperature, pressure and moisture profiles in High-Performance Concrete exposed to high temperatures during neutron radiography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toropovs, N., E-mail: nikolajs.toropovs@rtu.lv [Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf (Switzerland); Riga Technical University, Institute of Materials and Structures, Riga (Latvia); Lo Monte, F. [Politecnico di Milano, Department of Civil and Environmental Engineering, Milan (Italy); Wyrzykowski, M. [Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf (Switzerland); Lodz University of Technology, Department of Building Physics and Building Materials, Lodz (Poland); Weber, B. [Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf (Switzerland); Sahmenko, G. [Riga Technical University, Institute of Materials and Structures, Riga (Latvia); Vontobel, P. [Paul Scherrer Institute, Laboratory for Neutron Scattering and Imaging, Villigen (Switzerland); Felicetti, R. [Politecnico di Milano, Department of Civil and Environmental Engineering, Milan (Italy); Lura, P. [Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf (Switzerland); ETH Zürich, Institute for Building Materials (IfB), Zürich (Switzerland)

    2015-02-15

    High-Performance Concrete (HPC) is particularly prone to explosive spalling when exposed to high temperature. Although the exact causes that lead to spalling are still being debated, moisture transport during heating plays an important role in all proposed mechanisms. In this study, slabs made of high-performance, low water-to-binder ratio mortars with addition of superabsorbent polymers (SAP) and polypropylene fibers (PP) were heated from one side on a temperature-controlled plate up to 550 °C. A combination of measurements was performed simultaneously on the same sample: moisture profiles via neutron radiography, temperature profiles with embedded thermocouples and pore pressure evolution with embedded pressure sensors. Spalling occurred in the sample with SAP, where sharp profiles of moisture and temperature were observed. No spalling occurred when PP-fibers were introduced in addition to SAP. The experimental procedure described here is essential for developing and verifying numerical models and studying measures against fire spalling risk in HPC.

  11. Study on two-phase flow in a coolant channel of a plate-type fuel with use of neutron radiography technique

    International Nuclear Information System (INIS)

    Mishima, K.; Hibiki, T.; Nishihara, H.

    1992-01-01

    Two-phase flow in a narrow rectangular duct is important related to abnormal cooling conditions of a MTR type research reactor. In view of this, flow regime, void fraction, slug bubble velocity and pressure loss were measured for rectangular ducts with a narrow gap. The neutron radiography technique was used to visualize the flow and the void fraction was obtained by image processing. The void fraction was correlated well by the drift flux model with existing correlation for the distribution parameter which was about 1.35. Similar results were obtained for slug bubble velocity, however the distribution parameter was in the range from 1.0 to 1.2. The frictional pressure loss was correlated well by the Chisholm-Laird correlation. In collaboration with previously obtained data, it was found that the Chisholm's parameter C, however, changed from 21 to zero as the gap decreased. (author)

  12. The characterization of a neutron radiography Triga reactor for NAA of chlorine in an iron oxide matrix

    International Nuclear Information System (INIS)

    Glagolenko, I.; Carney, K.; Difelici, R.; Maddison, D.; Sayer, M.; Hart, P.; Ross, J.; Kahn, S.; Swanson, R.

    2000-01-01

    An irradiation position in the 250 kW Triga reactor was characterized for instrumental neutron activation analysis of chlorine in an iron oxide matrix. Factors that affect the accuracy of the determination include variations in the reactor neutron spectrum and flux as a function of spatial position and the presence of chlorine impurities. Gold wire and foils were used to determine the neutron flux and cadmium ratio as a function of height in an air-filled irradiation tube. (author)

  13. Miscellaneous neutron techniques

    International Nuclear Information System (INIS)

    Iddings, F.A.

    1976-01-01

    Attention is brought to the less often uses of neutrons in the areas of neutron radiography, well logging, and neutron gaging. Emphasis on neutron radiography points toward the isotopic sensitivity of the method versus the classical bulk applications. Also recognized is the ability of neutron radiography to produce image changes that correspond to thickness and density changes obtained in photon radiography. Similarly, neutron gaging applications center on the measurement of radiography. Similarly, neutron gaging applications center on the measurement of water, oil, or plastics in industrial samples. Well logging extends the neutron gaging to encompass many neutron properties and reactions besides thermalization and capture. Neutron gaging also gives information on organic structure and concentrations of a variety of elements or specific compounds in selected matrices

  14. Three-dimensional model of the thermo-hydrodynamic neutron interaction in the core of water reactors (stationary states)

    International Nuclear Information System (INIS)

    Mastrangelo, Victor.

    1977-01-01

    A thermo-hydrodynamic neutron interaction model for permanent working conditions is developed in the case of closed circuits (boiling water reactors) and open circuits (pressurized water reactors). Two numerical convergence acceleration methods are then worked out for the resolution of linear problems by successive iterations. A physical study is devoted to the convergence of the thermo-hydrodynamic neutron interaction process. The model developed is applied to the calculation of the power distribution for the core of a 980 MWe BWR-6 type boiling water power station and to the study of normal and accidental working configurations of the pressurized water core of a 900 MWe PWR-CP1 unit [fr

  15. Development of a small-aperture slit system for a high collimator ratio at the thermal neutron radiography facility in JRR-3

    International Nuclear Information System (INIS)

    Yasuda, Ryo; Nojima, Takehiro; Iikura, Hiroshi; Sakai, Takuro; Matsubayashi, Masahito

    2011-01-01

    A small-aperture slit system has been developed and installed to enhance the collimator ratio ('L/D') of the thermal neutron radiography facility (TNRF) in JRR-3. The degree of unsharpness on neutron images is reduced by increasing the L/D. The small-aperture slit system increased the L/D by creating a small aperture size ('D'). Image sharpness improved when the aperture size was reduced to below 10 mm by 10 mm in the TNRF. On the other hand, there was almost no difference in unsharpness on images obtained above 10 mm by 10 mm in aperture size. These results indicate that an aperture size of less than 10 mm by 10 mm should be used for high-spatial-resolution imaging at the TNRF. The beam area of the small-aperture slits was relatively small in comparison with that of a conventional large collimator, though gradually increasing with increasing aperture size. Even with an aperture size of 5 mm by 5 mm, the practical beam area for imaging examinations corresponded to around 25 mm by 20 mm, which is enough area to carry out high-spatial-resolution imaging. (author)

  16. Measurement of hydrogen distributions in iron and steel by means of neutron radiography and tomography; Messung von Wasserstoffverteilungen in Eisen und Stahl mittels Neutronenradiographie und -tomographie

    Energy Technology Data Exchange (ETDEWEB)

    Griesche, Axel; Kannengiesser, Thomas [BAM Bundesanstalt fuer Materialforschung und -pruefung, Berlin (Germany); Kardjilov, Nikolay; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB), Berlin (Germany); Schillinger, Burkhard [Technische Univ. Muenchen, Garching (Germany)

    2015-07-01

    In recent years, the optimization of the radiography measuring stations at research reactors and in particular the development of the neutron detectors has enabled the measurement of hydrogen distributions with ever higher spatial resolution at the same time more sensitive detection limit. Compared to iron, hydrogen has a high interaction cross-section for neutrons, and thus allows simple radiographic methods of the two and three dimensional visualization of hydrogen distribution in the structure. This allowed us for the first time the measurement of hydrogen diffusion flows in centimeter-thick steel samples with a temporal resolution of 20 s and the quantitative measurement of hydrogen accumulation of crack edges in hydrogen embrittled iron samples. It was also the first gaseous hydrogen detected in the cavities of the cracks and the pressure can be determined. This new quality of information on the microstructure scale granted unprecedented insights for the investigation of damage mechanisms e.g. in the hydrogen embrittlement. By providing local in-situ information that is not accessible by conventional methods such as carrier gas hot extraction, as well as analyzes can be performed in three dimensions with a spatial resolution of 20-30 μm. This article provides examples that use the spatial and temporal resolution of the neutron radiography and tomography to visualize hydrogen distributions in and around cracks and to quantify. The measurements were conducted at the research reactors BER II of HZB in Berlin and FRM II of teh neutron source Heinz Maier-Leibnitz in Garching. (This article contains PowerPoint slides). [German] In den letzten Jahren hat die Optimierung der Radiographie-Messplaetze an Forschungsreaktoren und hier insbesondere die Weiterentwicklung der Neutronendetektoren die Messung von Wasserstoffverteilungen mit immer hoeherer Ortsaufloesung bei gleichzeitig empfindlicherer Nachweisgrenze ermoeglicht. Wasserstoff besitzt im Vergleich zu Eisen

  17. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  18. Towards Hydrological Applications of Stationary and Roving Cosmic-Ray Neutron Sensors in the Light of Spatial Sensitivity

    Science.gov (United States)

    Schrön, M.; Köhli, M.; Rosolem, R.; Baroni, G.; Bogena, H. R.; Brenner, J.; Zink, M.; Rebmann, C.; Oswald, S. E.; Dietrich, P.; Samaniego, L. E.; Zacharias, S.

    2017-12-01

    Cosmic-Ray Neutron Sensing (CRNS) has become a promising and unique method to monitor water content at an effective scale of tens of hectares in area and tens of centimeters in depth. The large footprint is particularly beneficial for hydrological models that operate at these scales.However, reliable estimates of average soil moisture require a detailed knowledge about the sensitivity of the signal to spatial inhomogeneity within the footprint. From this perspective, the large integrating volume challenges data interpretation, validation, and calibration of the sensor. Can we still generate reliable data for hydrological applications? One of the top challenges in the last years was to find out where the signal comes from, and how sensitive it is to spatial variabilities of moisture. Neutron physics simulations have shown that the neutron signal represents a non-linearly weighted average of soil water in the footprint. With the help of the so-called spatial sensitivity functions it is now possible to quantify the contribution of certain regions to the neutron signal. We present examples of how this knowledge can help (1) to understand the contribution of irrigated and sealed areas in the footprint, (2) to improve calibration and validation of the method, and (3) to even reveal excess water storages, e.g. from ponding or rain interception.The spatial sensitivity concept can also explain the influence of dry roads on the neutron signal. Mobile surveys with the CRNS rover have been a common practice to measure soil moisture patterns at the kilometer scale. However, dedicated experiments across agricultural fields in Germany and England have revealed that field soil moisture is significantly underestimated when moving the sensor on roads. We show that knowledge about the spatial sensitivity helps to correct survey data for these effects, depending on road material, width, and distance from the road. The recent methodological advances allow for improved signal

  19. Military radiography

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Historic military uses of radiography are discussed in this chapter: Battle of Adowa in 1986 was the first. Besides describing the early campaigns in which radiography was used, the author discusses the problems faced: a reliable source of electricity; the problems of extreme heat; moving and breakage of equipment. Numerous historical photographs are included. 9 refs

  20. Neutron techniques

    International Nuclear Information System (INIS)

    Charlton, J.S.

    1986-01-01

    The way in which neutrons interact with matter such as slowing-down, diffusion, neutron absorption and moderation are described. The use of neutron techniques in industry, in moisture gages, level and interface measurements, the detection of blockages, boron analysis in ore feedstock and industrial radiography are discussed. (author)

  1. Application of COMSOL in the solution of the neutron diffusion equations for fast nuclear reactors in stationary state

    International Nuclear Information System (INIS)

    Silva A, L.; Del Valle G, E.

    2012-10-01

    This work shows an application of the program COMSOL Multi physics Ver. 4.2a in the solution of the neutron diffusion equations for several energy groups in nuclear reactors whose core is formed by assemblies of hexagonal transversal cut as is the cas of fast reactors. A reference problem of 4 energy groups is described of which takes the cross sections which are processed by means of a program that prepares the definition of the constants utilized in COMSOL for the generic partial differential equations that this uses. The considered solution domain is the sixth part of the core which is applied frontier conditions of reflection and incoming flux zero. The discretization mesh is elaborated in automatic way by COMSOL and the solution method is one of finite elements of Lagrange grade two. The reference problem is known as the Knk with and without control rod which led to propose the calculation of the effective multiplication factor in function of the control rod fraction from a value 0 (completely inserted control rod) until the value 1 (completely extracted control rod). Besides this the reactivity was determined as well as the change of this in function of control rod fraction. The neutrons scalar flux for each energy group with and without control rod is proportioned. The reported results show a behavior similar to the one reported in other works but using the discreet ordinates S 2 approximation. (Author)

  2. Sorption kinetics of superabsorbent polymers (SAPs) in fresh Portland cement-based pastes visualized and quantified by neutron radiography and correlated to the progress of cement hydration

    Energy Technology Data Exchange (ETDEWEB)

    Schroefl, Christof, E-mail: christof.schroefl@tu-dresden.de [Technische Universität Dresden, Fakultät Bauingenieurwesen, Institut für Baustoffe, DE-01062 Dresden (Germany); Mechtcherine, Viktor [Technische Universität Dresden, Fakultät Bauingenieurwesen, Institut für Baustoffe, DE-01062 Dresden (Germany); Vontobel, Peter; Hovind, Jan; Lehmann, Eberhard [Paul Scherrer Institut, Laboratory for Neutron Scattering and Imaging, CH-5232 Villigen/AG (Switzerland)

    2015-09-15

    Water sorption of two superabsorbent polymers in cement-based pastes has been characterized by neutron radiography. Cement pastes with W/C of 0.25 and 0.50 and one additionally containing silica fume (W/C = 0.42) were investigated. The SAPs differed in their inherent sorption kinetics in extracted cement pore solution (SAP 1: self-releasing; SAP 2: retentive). Desorption from SAP 1 started very early after paste preparation. Hence, its individual non-retentiveness governs its behavior only. SAP 2 released water into all matrices, but its kinetics were different. In the paste with the highest W/C, some moderate water release was recorded from the beginning. In the other two pastes, SAP 2 retained its stored liquid during the dormant period, i.e., up to the percolation threshold. Intense desorption then set in and continued throughout the acceleration period. These findings explain the pronouncedly higher efficiency of SAP 2 as internal curing admixture as compared to SAP 1.

  3. Sorption kinetics of superabsorbent polymers (SAPs) in fresh Portland cement-based pastes visualized and quantified by neutron radiography and correlated to the progress of cement hydration

    International Nuclear Information System (INIS)

    Schroefl, Christof; Mechtcherine, Viktor; Vontobel, Peter; Hovind, Jan; Lehmann, Eberhard

    2015-01-01

    Water sorption of two superabsorbent polymers in cement-based pastes has been characterized by neutron radiography. Cement pastes with W/C of 0.25 and 0.50 and one additionally containing silica fume (W/C = 0.42) were investigated. The SAPs differed in their inherent sorption kinetics in extracted cement pore solution (SAP 1: self-releasing; SAP 2: retentive). Desorption from SAP 1 started very early after paste preparation. Hence, its individual non-retentiveness governs its behavior only. SAP 2 released water into all matrices, but its kinetics were different. In the paste with the highest W/C, some moderate water release was recorded from the beginning. In the other two pastes, SAP 2 retained its stored liquid during the dormant period, i.e., up to the percolation threshold. Intense desorption then set in and continued throughout the acceleration period. These findings explain the pronouncedly higher efficiency of SAP 2 as internal curing admixture as compared to SAP 1

  4. Azimuthally anisotropic hydride lens structures in Zircaloy 4 nuclear fuel cladding: High-resolution neutron radiography imaging and BISON finite element analysis

    Science.gov (United States)

    Lin, Jun-Li; Zhong, Weicheng; Bilheux, Hassina Z.; Heuser, Brent J.

    2017-12-01

    High-resolution neutron radiography has been used to image bulk circumferential hydride lens particles in unirradiated Zircaloy 4 tubing cross section specimens. Zircaloy 4 is a common light water nuclear reactor (LWR) fuel cladding; hydrogen pickup, hydride formation, and the concomitant effect on the mechanical response are important for LWR applications. Ring cross section specimens with three hydrogen concentrations (460, 950, and 2830 parts per million by weight) and an as-received reference specimen were imaged. Azimuthally anisotropic hydride lens particles were observed at 950 and 2830 wppm. The BISON finite element analysis nuclear fuel performance code was used to model the system elastic response induced by hydride volumetric dilatation. The compressive hoop stress within the lens structure becomes azimuthally anisotropic at high hydrogen concentrations or high hydride phase fraction. This compressive stress anisotropy matches the observed lens anisotropy, implicating the effect of stress on hydride formation as the cause of the observed lens azimuthal asymmetry. The cause and effect relation between compressive stress and hydride lens anisotropy represents an indirect validation of a key BISON output, the evolved hoop stress associated with hydride formation.

  5. Observation and quantification of water penetration into Strain Hardening Cement-based Composites (SHCC) with multiple cracks by means of neutron radiography

    International Nuclear Information System (INIS)

    Zhang, P.; Wittmann, F.H.; Zhao, T.J.; Lehmann, E.H.; Tian, L.; Vontobel, P.

    2010-01-01

    Durability of reinforced concrete structures has become a crucial issue with respect to economy, ecology and sustainability. One major reason for durability problems of concrete structures is the limited strain capacity of cement-based materials under imposed tensile stress. By adding PVA fibers, a new material named Strain Hardening Cement-based Composites (SHCC) with high strain capacity can be produced. Due to the formation of multiple micro-cracks, wide cracks can be avoided in SHCC under an imposed strain. The high strain capacity, however, is beneficial with respect to durability only if the multi-crack formation in SHCC does not lead to significantly increased water penetration. If water and aggressive chemical compounds such as chlorides and sulfates dissolved in water penetrate into the cement-based matrix and reach the steel reinforcement service-life of reinforced concrete structures will be reduced significantly. In this project, neutron radiography was applied to observe and quantify the process of water penetration into uncracked SHCC and after the multi-crack formation. In addition, water penetration into integral water repellent cracked and uncracked SHCC, which has been produced by adding a silane-based water repellent agent to the fresh SHCC mortar has been investigated. Results will be discussed with respect to durability.

  6. Investigation of the role of the micro-porous layer in polymer electrolyte fuel cells with hydrogen deuterium contrast neutron radiography.

    Science.gov (United States)

    Cho, Kyu Taek; Mench, Matthew M

    2012-03-28

    In this study, the high resolution hydrogen-deuterium contrast radiography method was applied to elucidate the impact of the micro-porous layer (MPL) on water distribution in the porous fuel cell media. At the steady state, deuterium replaced hydrogen in the anode stream, and the large difference in neutron attenuation of the D(2)O produced at the cathode was used to track the produced water. It was found that the water content peaked in the cathode-side diffusion media (DM) for the cell without MPL, but with an MPL on the anode and cathode DM, the peak water amount was pushed toward the anode, resulting in a relatively flattened water profile through components and demonstrating a liquid barrier effect. Additionally, the dynamic water behavior in diffusion media was analyzed to understand the effect of a MPL and operating conditions. The water content in the DM changed with applied current, although there is a significant amount of residual liquid content that does not appear to be part of capillary channels. The effect of the MPL on irreducible saturation in DM and cell performance was also investigated.

  7. On the problems relating to the accuracy of the measurement of fuel pin diameters by neutron radiography

    International Nuclear Information System (INIS)

    Matfield, R.

    1983-01-01

    The paper identifies the sources of error in the neutron radiographic system and attempts to estimate some of these errors. The sources of error are in the fuel pin materials, the radiographic set-up, the radiographic equipment, image formation, the microdensitometer, the edge criteria and the dimensional measurement from the microdensitometer trace. However, the critical problem area is that of determining a representative edge criteria and upon this will depend the ability of the method to achieve the required measurement accuracy. (Auth.)

  8. Basic research of boron neutron-capture therapy for treatment of pancreatic cancer. Application of neutron radiography for visualization of boron compound on BNCT

    International Nuclear Information System (INIS)

    Yanagie, Hironobu

    1997-01-01

    The cytotoxic effects of locally injected 10 B-immunoliposomes (anti-CEA) on human pancreatic carcinoma xenografts in nude mice were evaluated with thermal neutron irradiation. After thermal neutron irradiation of mice injected with 10 B-immunoliposomes, AsPC-1 tumour growth was suppressed relative to controls. Histopathologically, hyalinization and necrosis were found in 10 B-treated tumours, while tumour tissue injected with saline or saline-containing immunoliposomes showed neither destruction nor necrosis. These results suggest that intratumoral injection of boronated immunoliposomes can increase the retention of 10 B atoms by tumour cells, causing tumour growth suppression in vivo upon thermal neutron irradiation. We prepared boronated PEG-binding bovine serum albumin ( 10 B-PEG-BSA). 10 B concentrations in AsPC-1, human pancreatic cancer cells (2 x 10 5 /well) obtained 24 hrs after incubation with 10 B-PEG-BSA was 13.01 ± 1.74 ppm. The number of 10 B atoms delivered to the tumor cells was calculated to be 7.83 x 10 11 at 24 hrs after incubation with 10 B-PEG-BSA. These data indicated that the 10 B-PEG-BSA could deliver a sufficient amount of 10 B atoms (more than 10 9 atoms/cell) to the tumor cells to induce cytotoxic effects after incubation upon thermal neutron irradiation. Neutron capture autoradiography by using an Imaging Plate (IP-NCR) was performed on AsPC-1 tumor-bearing mouse that had been given an intratumoral injection of 10 B-PEG BSA or 10 B-cationic liposome. We had demonstrated the 10 B-PEG BSA or 10 B-cationic liposome is taken up by AsPC-1 tumor tissue to a much greater extent than by normal tissues. (J.P.N.)

  9. Basic research of boron neutron-capture therapy for treatment of pancreatic cancer. Application of neutron radiography for visualization of boron compound on BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Yanagie, Hironobu [Tokyo Univ. (Japan). Inst. of Medical Science

    1997-02-01

    The cytotoxic effects of locally injected {sup 10}B-immunoliposomes (anti-CEA) on human pancreatic carcinoma xenografts in nude mice were evaluated with thermal neutron irradiation. After thermal neutron irradiation of mice injected with {sup 10}B-immunoliposomes, AsPC-1 tumour growth was suppressed relative to controls. Histopathologically, hyalinization and necrosis were found in {sup 10}B-treated tumours, while tumour tissue injected with saline or saline-containing immunoliposomes showed neither destruction nor necrosis. These results suggest that intratumoral injection of boronated immunoliposomes can increase the retention of {sup 10}B atoms by tumour cells, causing tumour growth suppression in vivo upon thermal neutron irradiation. We prepared boronated PEG-binding bovine serum albumin ({sup 10}B-PEG-BSA). {sup 10}B concentrations in AsPC-1, human pancreatic cancer cells (2 x 10{sup 5} /well) obtained 24 hrs after incubation with {sup 10}B-PEG-BSA was 13.01 {+-} 1.74 ppm. The number of {sup 10}B atoms delivered to the tumor cells was calculated to be 7.83 x 10{sup 11} at 24 hrs after incubation with {sup 10}B-PEG-BSA. These data indicated that the {sup 10}B-PEG-BSA could deliver a sufficient amount of {sup 10}B atoms (more than 10{sup 9} atoms/cell) to the tumor cells to induce cytotoxic effects after incubation upon thermal neutron irradiation. Neutron capture autoradiography by using an Imaging Plate (IP-NCR) was performed on AsPC-1 tumor-bearing mouse that had been given an intratumoral injection of {sup 10}B-PEG BSA or {sup 10}B-cationic liposome. We had demonstrated the {sup 10}B-PEG BSA or {sup 10}B-cationic liposome is taken up by AsPC-1 tumor tissue to a much greater extent than by normal tissues. (J.P.N.)

  10. International cooperative research with Japan for the establishment of cooperation structure and technology for dynamic neutron radiography using HANARO

    International Nuclear Information System (INIS)

    Lim, I. C.; Sim, C. M.; Lee, B. H.; Choi, Y. S.; Baek, W. P.; Cha, J. E.; Yoon, B. J.; Chu, I. C.

    2007-07-01

    DNR is the technique to obtain radiography image continuously using a imaging system and Japan is the leading country in this field. Considering that no research has been performed to obtain quantitative parameters using DNR in Korea, it was necessary to establish a cooperative structure with Japanese experts and to develop the DNR technique throughout this project. The objectives of the project were to conduct 4 cooperative experiments using the HANARO BNCT facility and to establish a relationship with Japanese experts which makes it possible to maintain continuous communication. 4 experiments such as the void fraction and flow pattern measurement in a channel simulating HANARO fuel channel, observation of flow field in Pb/Bi field and the observation of cavity in a diesel engine nozzle were successfully completed. Also, the continuos communication and cooperation between the experts of two countries will be made. In this sense, this project is believed as a model project to use the mega research facility such as HANARO for the international cooperation

  11. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  12. Non-Destructive Measurement Methods (Neutron-, X-ray Radiography, Vibration Diagnostics and Ultrasound) in the Inspection of Helicopter Rotor Blades

    National Research Council Canada - National Science Library

    Balasko, M; Endroczi, G; Tarnai, Gy; Veres, I; Molnar, Gy; Svab, E

    2005-01-01

    The experiments regarding structural failures in helicopter rotor blade's composite structures causing water penetrations and bypasses were performed at the Dynamic Radiography Station (DRS) of the Budapest...

  13. Industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    This Health and Safety Executive Information Sheet on industrial radiography aims to inform directors and managers of industrial radiography companies on the safety precautions necessary to ensure that their personnel do not exceed dose guidelines for exposure to ionizing radiation. The Ionising Radiations Regulations 1985 (IRR85) require that exposure doses for radiographers are kept as low reasonably practicable. Equipment maintenance, and the employment of proper emergency procedures will help to ensure personnel safety. (UK)

  14. Inspection of the metal composite materials using a combination of X-ray radiography and Neutron Imaging

    Czech Academy of Sciences Publication Activity Database

    Vavřík, Daniel; Jeon, I.; Lehmnann, E.; Kaestner, A.; Vacík, J.

    2011-01-01

    Roč. 6, č. 3 (2011), s. 186-191 ISSN 1748-0221. [International workshop on radiation imaging detectors /12./. Cambridge, 12.07.2010-15.07.2010] R&D Projects: GA ČR(CZ) GA103/09/2101 Grant - others:GA MŠk(CZ) LC06041; GA AV ČR(CZ) KAN400480701 Program:LC; KA Institutional research plan: CEZ:AV0Z20710524; CEZ:AV0Z10480505 Keywords : neutron imaging * detection of defects * computerized tomography * non destructive testing Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 1.869, year: 2011 http://iopscience.iop.org/1748-0221/6/03/C03001/

  15. Industrial radiography

    International Nuclear Information System (INIS)

    1992-01-01

    Industrial radiography is a non-destructive testing (NDT) method which allows components to be examined for flaws without interfering with their usefulness. It is one of a number of inspection methods which are commonly used in industry to control the quality of manufactured products and to monitor their performance in service. Because of its involvement in organizing training courses in all the common NDT methods in regional projects in Asia and the Pacific and Latin America and the Caribbean and in many country programmes, the Agency is aware of the importance of standardizing as far as possible the syllabi and training course notes used by the many experts who are involved in presenting the training courses. IAEA-TECDOC-628 ''Training Guidelines in Non-destructive Testing'' presents syllabi which were developed by an Agency executed UNDP project in Latin America and the Caribbean taking into account the developmental work done by the International Committee for Non-destructive Testing. Experience gained from using the radiography syllabi from TECDOC-628 at national and regional radiography training courses in the Agency executed UNDP project in Asia and the Pacific (RAS/86/073) showed that some guidance needed to be given to radiography experts engaged in teaching at these courses on the material which should be covered. The IAEA/UNDP Asia and Pacific Project National NDT Coordinators therefore undertook to prepare Radiography Training Course Notes which could be used by experts to prepare lectures for Level 1,2 and 3 radiography personnel. The notes have been expanded to cover most topics in a more complete manner than that possible at a Level 1, 2 or 3 training course and can now be used as source material for NDT personnel interested in expanding their knowledge of radiography. Refs, figs and tabs

  16. Dental radiography

    International Nuclear Information System (INIS)

    Shekhdar, J.

    1993-01-01

    Dental radiography must comply with the same regulations with which conventional radiography complies. Radiation doses to individual patients are low but, because of the large number of patients X-rayed, the collective dose to the population is not negligible. Care in siting and regular maintenance of the equipment will reduce doses to both staff and patients. To produce X-ray films with a good image quality using a low radiation dose requires attention to film processing; this is often a neglected area. (Author)

  17. Improvements in PIE-techniques at the IFE hot-laboratory. 'Neutron radiography, three dimensional profilometry and image compilation of PIE data for visualization in an image based user-interface'

    International Nuclear Information System (INIS)

    Jenssen, H.K.; Oberlaender, B.C.

    2002-01-01

    The PIE-techniques used at IFE are continuously improved through upgrading of equipment and methods, e.g. image handling techniques and components utilized in data acquisition and editing techniques. To improve the quality or spatial resolution of neutron radiographs the normal technique was complemented with another method, i.e. the dysprosium foil/X ray film technique is supplemented with a track-etch recorder consisting of a cellulose nitrate film. For further examination of the neutron radiographs the cellulose nitrate film can be digitized to allow electronic image treatment. Promising results were obtained with this technique on neutron radiographs, namely higher spatial resolution compared to the normal technique, high contrast and sharp neutron radiography images. The traditional uniaxial profilometry of fuel rods was modified so that diameter/bow measurements are possible at several angular orientations during one acquisition sequence. This extension is very useful in several ways, for instance the built-in data symmetry of the method is used to check the correctness of the measurement results. Diameter and bow measurements give information of cladding irregularities and fuel rod profiles. Implementation of electronic image handling techniques is particularly useful in PIE when data are collected and compiled in an image file. Inspection and examination of the file contents (examination results) are possible through an ideal user-interface, i.e. Adobe Photoshop software with navigator possibilities. Examples incorporating PIE data acquired from neutron radiography, visual inspection and ceramography are utilized for illustration of the user-interface and some of its possibilities. (author)

  18. Industrial radiography

    International Nuclear Information System (INIS)

    Aloni, A.; Magal, O.

    1992-02-01

    This publication is meant to be a manual for industrial radiography. As such the manual concentrates on the practical aspects, presenting existing radiographic system and techniques of operation to satisfy specified quality requirements. The manual also reviews the safety aspect of performing radiographic work. (author) systems

  19. Radiography technique

    Energy Technology Data Exchange (ETDEWEB)

    Panaiotov, L N

    1951-10-23

    A new method of hollow articles radiography is presented enabling to eliminate shortcomings coupled with medical personnel irradiation when the ampoule incorporating radioactive substance is removed from the protective container and adjusted in the article. The method presented permits to transport the ampoule from the protective container immediately into the inner cavity of the article.

  20. Skull Radiography

    Science.gov (United States)

    What you need to know about… Skull Radiography X-ray images of the skull are taken when it is necessary to see the cranium, facial bones or jaw bones. ... Among other things, x-ray exams of the skull can show fractures. Patient Preparation Before the examination, ...

  1. Progress in digital radiography

    International Nuclear Information System (INIS)

    Cappelle, A.

    2016-01-01

    Because of its practical aspect digital radiography is more and more used in the industrial sector. There are 2 kinds of digital radiography. First, the 'computed radiography' that uses a photon-stimulated screen, and after radiation exposure this screen must be read by an analyser to get a digit image. The second type is the 'direct radiography' that allows one to get a digit radiograph of the object directly. Digital radiography uses the same radioactive nuclides as radiography with silver films: cobalt, iridium or selenium. The spatial resolution of digital radiography is less good than with classical silver film radiography but digital radiography offers a better visual contrast. (A.C.)

  2. INR TRIGA Research Reactors: A Neutron Source for Radioisotopes and Materials Investigation

    International Nuclear Information System (INIS)

    Barbos, D.; Ciocanescu, M.; Paunoiu, C.; Bucsa, A.F.

    2013-01-01

    At the INR there are 2 high intensity neutron sources. These sources are in fact the two nuclear TRIGA reactors: TRIGA SSR 14 MW and TRIGA ACPR. TRIGA stationary reactor is provided with several in-core irradiation channels. Other several out-of-core irradiation channels are located in the vertical channels in the beryllium reflector blocks. The maximum value of the thermal neutron flux (E 14 cm -2 s -1 and of fast neutron flux (E>1 MeV) is 6.89×10 13 cm -2 s -1 . For neutron activation analysis both reactors are used and k0-NAA method has been implemented. At INR Pitesti a prompt gamma ray neutron activation analysis devices has been designed, manufactured ant put into operation. For nuclear materials properties investigation neutron radiography methods was developed in INR. For these purposes two neutron radiography devices were manufacture, one of them underwater and other one dry. The neutron beams are used for investigation of materials properties and components produced or under development for applications in the energy sector (fission and fusion). At TRIGA 14 MW reactor a neutron difractormeter and a SANS devices are available for material residual stress and texture measurements. TRIGA 14 MW reactor is used for medical and industrial radioisotopes production ( 131 I, 125 I, 192 Ir, etc) and a method for 99 Mo- 99 Tc production from fission is under developing. At INR Pitesti several special programmes for new types of nuclear fuel behavior characterization are under development. (author)

  3. Digital radiography

    International Nuclear Information System (INIS)

    Brody, W.R.

    1984-01-01

    Digital Radiography begins with an orderly introduction to the fundamental concepts of digital imaging. The entire X-ray digital imagining system is described, from an overall characterization of image quality to specific components required for a digital radiographic system. Because subtraction is central to digital radiographic systems, the author details the use of various subtraction methods for image enhancement. Complex concepts are illustrated with numerous examples and presented in terms that can readily be understood by physicians without an advanced mathematics background. The second part of the book discusses implementations and applications of digital imagining systems based on area and scanned detector technologies. This section includes thorough coverage of digital fluoroscopy, scanned projection radiography, and film-based digital imaging systems, and features a state-of-the-art synopsis of the applications of digital subtraction angiography. The book concludes with a timely assessment of anticipated technological advances

  4. Ambulating radiography

    International Nuclear Information System (INIS)

    Magnusson, K.

    1989-01-01

    Strong gamme or X-ray sources are utilized for non-destructive testing of i.e. bridges. The activities involve certain risks of accident that might lead to serious injuries caused by radiation. The National Institute of Radiation Protection has during the laste decade greatly yhe inspection rate in this area. It has today made controls of most enterprieses running ambulating radiography. (O.S.)

  5. Computed radiography

    International Nuclear Information System (INIS)

    Pupchek, G.

    2004-01-01

    Computed radiography (CR) is an image acquisition process that is used to create digital, 2-dimensional radiographs. CR employs a photostimulable phosphor-based imaging plate, replacing the standard x-ray film and intensifying screen combination. Conventional radiographic exposure equipment is used with no modification required to the existing system. CR can transform an analog x-ray department into a digital one and eliminates the need for chemicals, water, darkrooms and film processor headaches. (author)

  6. Magnification radiography

    International Nuclear Information System (INIS)

    Genant, H.K.; Resnick, D.

    1988-01-01

    The relative clinical value of magnification compared with conventional radiography for skeletal applications is presented qualitatively. The presentation is based on the authors' experience with over 25,000 cases in which magnification has been used. For most areas in which magnification (optical or geometric) proves useful, subtle abnormalities of clinical importance are present at bone surfaces or at host-lesion interfaces. This is particularly true for arthritis and metabolic and infectious disorders of bone. In additional instances, serial assessment of the progression of disease or its response to therapy is enhanced by magnification. When gross abnormalities are present, as in most instances of trauma and bone dysplasia, the findings are obvious on conventional radiography, and magnification is not necessary. Thus, the magnification techniques appear to provide important diagnostic information, depending upon the anatomic part that is studied and the clinical question that is posed. It is also apparent that the demonstration of subtle skeletal abnormalities to clinical colleagues for educational purposes is greatly enhanced by magnification radiography

  7. Container Inspection Utilizing 14 MeV Neutrons

    Science.gov (United States)

    Valkovic, Vladivoj; Sudac, Davorin; Nad, Karlo; Obhodas, Jasmina

    2016-06-01

    A proposal for an autonomous and flexible ship container inspection system is presented. This could be accomplished by the incorporation of an inspection system on various container transportation devices (straddle carriers, yard gentry cranes, automated guided vehicles, trailers). The configuration is terminal specific and it should be defined by the container terminal operator. This enables that no part of the port operational area is used for inspection. The inspection scenario includes container transfer from ship to transportation device with the inspection unit mounted on it. The inspection is performed during actual container movement to the container location. A neutron generator without associated alpha particle detection is used. This allows the use of higher neutron intensities (5 × 109 - 1010 n/s in 4π). The inspected container is stationary in the “inspection position” on the transportation device while the “inspection unit” moves along its side. The following analytical methods will be used simultaneously: neutron radiography, X-ray radiography, neutron activation analysis, (n, γ) and (n,n'γ) reactions, neutron absorption. and scattering, X-ray backscattering. The neutron techniques will utilize “smart collimators” for neutrons and gamma rays, both emitted and detected. The inspected voxel is defined by the intersection of the neutron generator and the detectors solid angles. The container inspection protocol is based on identification of discrepancies between the cargo manifest, elemental “fingerprint” and radiography profiles. In addition, the information on container weight is obtained during the container transport and screening by measuring of density of material in the container.

  8. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  9. Radiography shielding

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.

    1985-11-27

    Apparatus for the inspection of a pipe weld by radiography comprises a radiation source contained in a housing having a first collimator for defining the exit beam and a second collimator mountable on the pipe in the region of the weld to define with the first collimator a predetermined volume enclosing the radiation beam passing through the second collimator when the housing is in a predetermined position relative to the second collimator. The arrangement is such that if the housing is slightly displaced from the predetermined position the radiation beam still falls within the predetermined volume.

  10. Radiography shielding

    International Nuclear Information System (INIS)

    Redmayne, I.

    1985-01-01

    Apparatus for the inspection of a pipe weld by radiography comprises a radiation source contained in a housing having a first collimator for defining the exit beam and a second collimator mountable on the pipe in the region of the weld to define with the first collimator a predetermined volume enclosing the radiation beam passing through the second collimator when the housing is in a predetermined position relative to the second collimator. The arrangement is such that if the housing is slightly displaced from the predetermined position the radiation beam still falls within the predetermined volume. (author)

  11. Digital Radiography

    Science.gov (United States)

    1986-01-01

    System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.

  12. Digital radiography

    International Nuclear Information System (INIS)

    Elander, S.; Hellesnes, J.; Reitan, J.B.

    1992-01-01

    The technology of radiography is developing rapidly, both regarding imaging technology and data hardware, and software technology. More and more advanced systems are marketed by the radiological companies. The wide product range makes it difficult to get an overview over principles and components. By closer inspection, however, the number of basic components and technologies is limited. Moreover, the components seem rather well known from other technologies, due to the long times of development in radiology. This report gives a survey of some new principles and components in the video chain. As components may deteriorate or age fast by irradiation, the radiation levels in the chain are evaluated. 13 refs

  13. Radiography apparatus

    International Nuclear Information System (INIS)

    Sashin, D.; Sternglass, E.J.

    1982-01-01

    The apparatus of the present invention provides radiography apparatus wherein the use of a flat, generally rectangular beam or a fan-shaped beam of radiation in combination with a collimator, scintillator and device for optically coupling a self-scanning array of photodiodes to the scintillator means will permit production of images or image data with high contrast sensitivity and detail. It is contemplated that the self-scanning array of photodiodes may contain from about 60 to 2048, and preferably about 256 to 2048, individual photodiode elements per inch of object width, thereby permitting maximum data collection to produce a complete image or complete collection of image data

  14. Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques

    International Nuclear Information System (INIS)

    Harvel, G.D.; Hori, K.; Kawanishi, K.

    1995-01-01

    A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,θ) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined

  15. Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques

    Energy Technology Data Exchange (ETDEWEB)

    Harvel, G.D. [McMaster Univ., Ontario (Canada)]|[Combustion and Heat Transfer Lab., Takasago (Japan); Hori, K.; Kawanishi, K. [Combustion and Heat Transfer Lab., Takasago (Japan)] [and others

    1995-09-01

    A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

  16. Electron radiography

    Science.gov (United States)

    Merrill, Frank E.; Morris, Christopher

    2005-05-17

    A system capable of performing radiography using a beam of electrons. Diffuser means receive a beam of electrons and diffuse the electrons before they enter first matching quadrupoles where the diffused electrons are focused prior to the diffused electrons entering an object. First imaging quadrupoles receive the focused diffused electrons after the focused diffused electrons have been scattered by the object for focusing the scattered electrons. Collimator means receive the scattered electrons and remove scattered electrons that have scattered to large angles. Second imaging quadrupoles receive the collimated scattered electrons and refocus the collimated scattered electrons and map the focused collimated scattered electrons to transverse locations on an image plane representative of the electrons' positions in the object.

  17. Filmless Radiography

    Science.gov (United States)

    1997-01-01

    Technology initially prototyped under a Small Business Innovation Research contract between Quantex Corporation and Langley Research Center was licensed to Liberty Technology and incorporated into RADView, a new filmless radiography technology. The NASA-sponsored work involved the investigation of Electron Trapping, which led to a solid-state film that uses a special class of photoluminescent materials to capture radiographic images. RadView is a total imaging solution for the conversion of radiographic film records to digital format and digital acquisitions of radiographs. With the RADView technology, there is a reduction of exposure times and errors; film waste is eliminated; and the efficiency of data management and precise image analysis is boosted. The solid-state film can be exposed, read, erased, and re- exposed indefinitely until mechanical replacement is required. Digital images can be stored to optical media for up to 100 years and beyond without information loss.

  18. System for uncollimated digital radiography

    Science.gov (United States)

    Wang, Han; Hall, James M.; McCarrick, James F.; Tang, Vincent

    2015-08-11

    The inversion algorithm based on the maximum entropy method (MEM) removes unwanted effects in high energy imaging resulting from an uncollimated source interacting with a finitely thick scintillator. The algorithm takes as input the image from the thick scintillator (TS) and the radiography setup geometry. The algorithm then outputs a restored image which appears as if taken with an infinitesimally thin scintillator (ITS). Inversion is accomplished by numerically generating a probabilistic model relating the ITS image to the TS image and then inverting this model on the TS image through MEM. This reconstruction technique can reduce the exposure time or the required source intensity without undesirable object blurring on the image by allowing the use of both thicker scintillators with higher efficiencies and closer source-to-detector distances to maximize incident radiation flux. The technique is applicable in radiographic applications including fast neutron, high-energy gamma and x-ray radiography using thick scintillators.

  19. Industrial radiographies

    CERN Multimedia

    2005-01-01

    The Radiation Protection group wishes to remind CERN staff responsible for contractors performing X-ray inspections on the CERN sites that the firms must apply the legislation in force in their country of origin, in particular with regard to the prevention of risks relating to ionizing radiation. Industrial radiography firms called on to work on the CERN sites must also comply with the rules laid down in CERN's Radiation Safety Manual and be registered in the relevant CERN database. Since CERN is responsible for safety on its own site, a number of additional rules have been laid down for this kind of work, as set out in Radiation Protection Procedure PRP30 https://edms.cern.ch/file/346848/LAST_RELEASED/PRP30.pdf The CERN Staff Member responsible for the contract shall register the company and issue notification that an X-ray inspection is to be performed via the web interface at the following address: http://cern.ch/rp-radio

  20. Use of neutron beams for low and medium flux research reactors: Radiography and materials characterization. Report of a technical committee held in Vienna, 4-7 May 1993

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The present report is the result of the Technical Committee meeting held during 4-7 May 1993 in Vienna, Austria, and includes contributions from the participants. The Physics Section of the Department of Research and Isotopes was responsible for the co-ordination and compilation of the report. The report is intended to provide guidelines to research reactor owners and operators for promoting and developing their research programmes and industrial applications for neutron radiology, related neutron inspection and analytical techniques and neutron beam irradiation. Refs, figs and tabs.

  1. Use of neutron beams for low and medium flux research reactors: Radiography and materials characterization. Report of a technical committee held in Vienna, 4-7 May 1993

    International Nuclear Information System (INIS)

    1995-10-01

    The present report is the result of the Technical Committee meeting held during 4-7 May 1993 in Vienna, Austria, and includes contributions from the participants. The Physics Section of the Department of Research and Isotopes was responsible for the co-ordination and compilation of the report. The report is intended to provide guidelines to research reactor owners and operators for promoting and developing their research programmes and industrial applications for neutron radiology, related neutron inspection and analytical techniques and neutron beam irradiation. Refs, figs and tabs

  2. Container inspection in the port container terminal by using 14 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Valkovic, Vladivoj [Institute Ruder Boskovic, Zagreb (Croatia); Kvinticka 62, Zagreb (Croatia); Sudac, Davorin; Nad, Karlo; Obhodas, Jasmina [Ruder Boskovic Institute, Bijenicka c.54, Zagreb (Croatia)

    2015-07-01

    A proposal for an autonomous and flexible ship container inspection system is presented. This could be accomplished by the incorporation of inspection system on the container transportation devices (straddle carriers, yard gentry cranes automated guided vehicles, trailers). This configuration is terminal specific and it will be decided by container terminal operator. In such a way no part of port operational area will be used for inspection. The inspection scenario will include container transfer from ship to transportation device with inspection unit mounted on it, inspection during container movement to the container location. A neutron generator without associated alpha particle detection will be used. This will allow the use of higher neutron intensity (5x10{sup 9} - 10{sup 10} n/s in 4π). The inspected container will be stationary in the 'inspection position' on the transportation device while the 'inspection unit' will move along its side. Following analytical methods will be used simultaneously: neutron radiography, X-ray radiography, neutron activation analysis, (n,γ) and (n,n'γ) reactions, neutron absorption, and scattering, X-ray backscattering, Neutron techniques will take the advantage of using 'smart collimators' for neutrons and gammas, both emitted and detected. The inspected voxel will be defined by intersections/union of neutron generator and detectors solid angles. The container inspection protocol will be based on identification of discrepancies between its cargo manifest and its elemental 'fingerprint' and radiography profiles. In addition, the information on container weight will be obtained during the container transport and foreseen screening from the measurement of density of material in the container. (authors)

  3. Problems and prospects of neutron imaging

    International Nuclear Information System (INIS)

    Kobayashi, Hisao

    2008-01-01

    Technical problems and future prospects of neutron imaging and neutron radiography are reviewed and discussed for further development. For technical problems, neutron sources together with cold neutron, ultra-cold neutron, epithermal and fast-neutron beams, energy converters, and the intensity of neutron beam, dynamic range associated with imaging procedure, etc, are reviewed. As standardization, such indicators as beam purity, sensitivity, image quality, and beam quality are discussed and limitation of neutron radiography is also presented. As neutron imaging has developed as a nondestructive testing technique in industrial applications, further problems and prospects of quality control and qualification to perform neutron radiography, standardization and international cooperation of neutron imaging are discussed. (S. Ohno)

  4. New developments in radiography. An overview

    International Nuclear Information System (INIS)

    Berger, H.; Orphan, V.

    1983-01-01

    Techniques for radiographic inspection are undergoing change. Changes in X-ray sources include higher voltage and current, pulse techniques, smaller focal spots, portability, ease-of-use, and high reliability. Detector improvements include better films, screens and scintillators, real-time methods, electrostatic methods and solid state detectors. We now use many radiation for radiography (X-rays, gamma rays, neutrons and charged particles) and can process radiographic information to accomplish such things as image enhancement, tomography and digital radiography. In this review, the authors discuss some of these developments, many of which have not been applied - or widely applied in the nuclear industry

  5. ;Study of secondary hydriding at high temperature in zirconium based nuclear fuel cladding tubes by coupling information from neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and laser induced breakdown spectroscopy microprobe

    Science.gov (United States)

    Brachet, Jean-Christophe; Hamon, Didier; Le Saux, Matthieu; Vandenberghe, Valérie; Toffolon-Masclet, Caroline; Rouesne, Elodie; Urvoy, Stéphane; Béchade, Jean-Luc; Raepsaet, Caroline; Lacour, Jean-Luc; Bayon, Guy; Ott, Frédéric

    2017-05-01

    This paper gives an overview of a multi-scale experimental study of the secondary hydriding phenomena that can occur in nuclear fuel cladding materials exposed to steam at high temperature (HT) after having burst (loss-of-coolant accident conditions). By coupling information from several facilities, including neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and micro laser induced breakdown spectroscopy, it was possible to map quantitatively, at different scales, the distribution of oxygen and hydrogen within M5™ clad segments having experienced ballooning and burst at HT followed by steam oxidation at 1100 and 1200 °C and final direct water quenching down to room temperature. The results were very reproducible and it was confirmed that internal oxidation and secondary hydriding at HT of a cladding after burst can lead to strong axial and azimuthal gradients of hydrogen and oxygen concentrations, reaching 3000-4000 wt ppm and 1.0-1.2 wt% respectively within the β phase layer for the investigated conditions. Consistent with thermodynamic and kinetics considerations, oxygen diffusion into the prior-β layer was enhanced in the regions highly enriched in hydrogen, where the α(O) phase layer is thinner and the prior-β layer thicker. Finally the induced post-quenching hardening of the prior-β layer was mainly related to the local oxygen enrichment. Hardening directly induced by hydrogen was much less significant.

  6. Neutron source

    International Nuclear Information System (INIS)

    Cason, J.L. Jr.; Shaw, C.B.

    1975-01-01

    A neutron source which is particularly useful for neutron radiography consists of a vessel containing a moderating media of relatively low moderating ratio, a flux trap including a moderating media of relatively high moderating ratio at the center of the vessel, a shell of depleted uranium dioxide surrounding the moderating media of relatively high moderating ratio, a plurality of guide tubes each containing a movable source of neutrons surrounding the flux trap, a neutron shield surrounding one part of each guide tube, and at least one collimator extending from the flux trap to the exterior of the neutron source. The shell of depleted uranium dioxide has a window provided with depleted uranium dioxide shutters for each collimator. Reflectors are provided above and below the flux trap and on the guide tubes away from the flux trap

  7. Evidence-based radiography

    International Nuclear Information System (INIS)

    Hafslund, Bjorg; Clare, Judith; Graverholt, Birgitte; Wammen Nortvedt, Monica

    2008-01-01

    Evidence-based practice (EBP) offers the integration of the best research evidence with clinical knowledge and expertise and patient values. EBP is a well known term in health care. This paper discusses the implementation of EBP into radiography and introduces the term evidence-based radiography. Evidence-based radiography is radiography informed and based on the combination of clinical expertise and the best available research-based evidence, patient preferences and resources available. In Norway, EBP in radiography is being debated and radiographers are discussing the challenges of implementing EBP in both academic and clinical practice. This discussion paper explains why EBP needs to be a basis for a radiography curriculum and a part of radiographers' practice. We argue that Norwegian radiographers must increase participation in research and developing practice within their specific radiographic domain

  8. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Duchazeaubeneix, J.C.; Faivre, J.C.; Garreta, D.

    1982-10-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: direct 3- dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore, it is a well adapted method to gating techniques allowing the radiography of fast periodic moving systems. Results obtained on different objects (light and heavy materials) are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiography faster and to get a practical method are discussed

  9. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1982-04-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: 3-dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore the nuclear scattering radiography (NSR) is a well adapted method to gating techniques allowing the radiography of fast periodic moving objects. Results obtained on phantoms, formalin fixed head and moving object are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiograph faster and to get a practical method are discussed

  10. Neutron diagnostic investigations with a research reactor

    International Nuclear Information System (INIS)

    Harms, A.A.

    1977-01-01

    Some aspects of the use of neutron transmission analysis in applied research, as pursued at McMaster University (Canada), are examined. Examples considered are void measurements in two-phase flow, neutron conversion enhancement in neutron radiography, reconstruction of interior bulk heterogenities in solids and temperature sensing with neutrons. (author)

  11. Radiography - A conceptual approach

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, Sanna-Mari [Department of Nursing Science and Health Administration, University of Oulu, P.O. Box 5000, FIN-90014 (Finland)], E-mail: sanna-mari.ahonen@oulu.fi

    2008-11-15

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline.

  12. Radiography - A conceptual approach

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari

    2008-01-01

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline

  13. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  14. First results of micro-neutron tomography by use of a focussing neutron lens

    CERN Document Server

    Masschaele, B; Cauwels, P; Dierick, M; Jolie, J; Mondelaers, W

    2001-01-01

    Since the appearance of high flux neutron beams, scientists experimented with neutron radiography. This high beam flux combined with modern neutron to visible light converters leads to the possibility of performing fast neutron micro-tomography. The first results of cold neutron tomography with a neutron lens are presented in this article. Samples are rotated in the beam and the projections are recorded with a neutron camera. The 3D reconstruction is performed with cone beam reconstruction software.

  15. Application of COMSOL in the solution of the neutron diffusion equations for fast nuclear reactors in stationary state; Aplicacion de COMSOL en la solucion de las ecuaciones de difusion de neutrones para reactores nucleares rapidos en estado estacionario

    Energy Technology Data Exchange (ETDEWEB)

    Silva A, L.; Del Valle G, E., E-mail: evalle@ipn.mx [IPN, Escuela Superior de Fisica y Matematicas, Av. IPN s/n, Col. San Pedro Zacatenco, 07738 Mexico D. F. (Mexico)

    2012-10-15

    This work shows an application of the program COMSOL Multi physics Ver. 4.2a in the solution of the neutron diffusion equations for several energy groups in nuclear reactors whose core is formed by assemblies of hexagonal transversal cut as is the cas of fast reactors. A reference problem of 4 energy groups is described of which takes the cross sections which are processed by means of a program that prepares the definition of the constants utilized in COMSOL for the generic partial differential equations that this uses. The considered solution domain is the sixth part of the core which is applied frontier conditions of reflection and incoming flux zero. The discretization mesh is elaborated in automatic way by COMSOL and the solution method is one of finite elements of Lagrange grade two. The reference problem is known as the Knk with and without control rod which led to propose the calculation of the effective multiplication factor in function of the control rod fraction from a value 0 (completely inserted control rod) until the value 1 (completely extracted control rod). Besides this the reactivity was determined as well as the change of this in function of control rod fraction. The neutrons scalar flux for each energy group with and without control rod is proportioned. The reported results show a behavior similar to the one reported in other works but using the discreet ordinates S{sub 2} approximation. (Author)

  16. Other applications of neutron beams in material sciences

    International Nuclear Information System (INIS)

    Novion, C.H. de

    1997-01-01

    The various applications of neutron beams are reviewed. The different mechanisms involved in neutron interaction with matter are explained. We notice that generally neutron radiation effects are unfavorable but can be turned into efficient tools to add new structures or properties to materials, silicon doping is an example. The basis principles of neutron activation analysis and neutron radiography are described. (A.C.)

  17. Transitioning to digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, F., E-mail: Francisco.Miranda@pwc.ca [Pratt & Whitney Canada, Longueuil, Quebec (Canada)

    2015-09-15

    This article provides insight on the technical and business considerations necessary to implement or to transition to digital radiography Continued refinements in digital radiography technology have resulted in significant improvements in image quality and detectability of indications. These improvements have resulted in the acceptance of the technology by users and aerospace primes for final product inspection and disposition. Digital radiography has also been identified as an interesting cost reduction initiative with the potential of providing gains in productivity through increased throughput and decreased inspection lead-times and resulting costs. (author)

  18. Other applications of neutron beams in material sciences; Autres utilisations des faisceaux de neutrons en science des materiaux

    Energy Technology Data Exchange (ETDEWEB)

    Novion, C.H. de

    1997-12-31

    The various applications of neutron beams are reviewed. The different mechanisms involved in neutron interaction with matter are explained. We notice that generally neutron radiation effects are unfavorable but can be turned into efficient tools to add new structures or properties to materials, silicon doping is an example. The basis principles of neutron activation analysis and neutron radiography are described. (A.C.)

  19. Modern trends in the development of position sensitive neutron ...

    Indian Academy of Sciences (India)

    tions, e.g. single crystal neutron diffraction, neutron radiography and tomography. .... ated in the electric field between the cathode and anode and cause the ionization ... highly resistive wire can be attached to all the cathode segments and ...

  20. Charged Particle Radiography

    International Nuclear Information System (INIS)

    Morris, Chris

    2004-01-01

    The Coulomb multiple scattering of charged particles as they pass through material allows them to be used as a radiographic probe. This forms the basis for a new kind of radiography that is finding application where conventional x-ray radiography is limited by flux or backgrounds. Charged-particle radiography is providing a versatile new probe that has advantages over conventional x-ray radiography for some unique application. Proton radiography has been used to make quantitative motion pictures of high explosive driven experiments and proves to be of great value for radiographing experiments that mock up nuclear weapon primaries for stockpile certification. By taking advantage of magnetic lens to magnify images and by using the very bright beams that can be made with electrons, charged-particle radiography may be useful for studying the fine spatial detail and very fast motion in laser driven implosion experiments at the National Ignition Facility. Finally, radiographs can be made using cosmic-ray muons for searching vehicles and cargo containers for surreptitious cargo of high z materials such as uranium or plutonium.