  1. Estimation of station blackout frequency in FBTR

    International Nuclear Information System (INIS)

    Senthil Kumar, C.; John Arul, A.; Anandapadmanaban, B.; Marimuthu, S.; Singh, Om Pal

    2002-01-01

    Full text: In this paper, station blackout (SBO) frequency is computed as a function of blackout duration based on available data in FBTR. The frequency of loss of offsite power (LOSP) at FBTR is found to be 5.2/year. The data on the LOSP and failure data on feeders and transformers at FBTR are used to arrive at the frequency of LOSP as a function of down time for single feeder and double feeder cases. The non-recovery probability of offsite power failure with time is well represented by exponential distribution for times less than 2 h and Weibull distribution beyond 2 h. The unavailability of onsite emergency power supply was evaluated using Markov method and fault tree method and is 1.0E-2 and 3.34E-3 respectively. Using the above data and the non-recovery probability of DG, frequency of SBO at FBTR with single feeder and double feeder cases, for different time durations were evaluated. It is found that the frequency of station blackout at FBTR with double feeder computed using Markov method is ∼10 -4 /yr for 11 h and 10 -5 /yr for 19 h duration. With one feeder out of service the SBO frequency is more by a factor 5. Sensitivity study done with respect to DG repair time and common cause failure indicate that the results in the magnitude of SBO could be uncertain by a factor of ten. The uncertainty is less for shorter SBO duration and more for longer SBO duration

  2. Station blackout core damage frequency in an advanced nuclear reactor

    International Nuclear Information System (INIS)

    Carvalho, Luiz Sergio de

    2004-01-01

    Even though nuclear reactors are provided with protection systems so that they can be automatically shut down in the event of a station blackout, the consequences of this event can be severe. This is because many safety systems that are needed for removing residual heat from the core and for maintaining containment integrity, in the majority of the nuclear power plants, are AC dependent. In order to minimize core damage frequency, advanced reactor concepts are being developed with safety systems that use natural forces. This work shows an improvement in the safety of a small nuclear power reactor provided by a passive core residual heat removal system. Station blackout core melt frequencies, with and without this system, are both calculated. The results are also compared with available data in the literature. (author)

  3. Extension of station blackout coping capability and implications on nuclear safety

    Energy Technology Data Exchange (ETDEWEB)

    Volkanovski, Andrija, E-mail: andrija.volkanovski@ijs.si [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Prošek, Andrej [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia)

    2013-02-15

    Highlights: ► Modifications enhancing station blackout coping capability are analyzed. ► Analysis is done with deterministic and probabilistic safety analysis methods. ► The core heat up is delayed for at least the extension time interval. ► Auxiliary feedwater system delays core heat up even in presence of pumps seal leakage. ► Extension of station blackout coping capability decreases core damage frequency. -- Abstract: The safety of the nuclear power plant depends on the availability of the continuous and reliable sources of electrical energy during all modes of operation of the plant. The station blackout corresponds to a total loss of all alternate current (AC) power as a result of complete failure of both offsite and on-site AC power sources. The electricity for the essential systems during station blackout is provided from the batteries installed in the nuclear power plant. The results of the probabilistic safety assessment show that station blackout is one of the main and frequently the dominant contributor to the core damage frequency. The accident in Fukushima Daiichi nuclear power plants demonstrates the vulnerability of the currently operating nuclear power plants during the extended station blackout events. The objective of this paper is, considering the identified importance of the station blackout initiating event, to assess the implications of the strengthening of the SBO mitigation capability on safety of the NPP. The assessment is done with state-of-art deterministic and probabilistic methods and tolls with application on reference models of nuclear power plants. The U.S. NRC Station Blackout Rule describes procedure for the assessment of the size and capacity of the batteries in the nuclear power plant. The description of the procedure with the application on the reference plant and identified deficiencies in the procedure is presented. The safety analysis is done on reference model of the nuclear power plant. Obtained results show large

  4. Extension of station blackout coping capability and implications on nuclear safety

    International Nuclear Information System (INIS)

    Volkanovski, Andrija; Prošek, Andrej

    2013-01-01

    Highlights: ► Modifications enhancing station blackout coping capability are analyzed. ► Analysis is done with deterministic and probabilistic safety analysis methods. ► The core heat up is delayed for at least the extension time interval. ► Auxiliary feedwater system delays core heat up even in presence of pumps seal leakage. ► Extension of station blackout coping capability decreases core damage frequency. -- Abstract: The safety of the nuclear power plant depends on the availability of the continuous and reliable sources of electrical energy during all modes of operation of the plant. The station blackout corresponds to a total loss of all alternate current (AC) power as a result of complete failure of both offsite and on-site AC power sources. The electricity for the essential systems during station blackout is provided from the batteries installed in the nuclear power plant. The results of the probabilistic safety assessment show that station blackout is one of the main and frequently the dominant contributor to the core damage frequency. The accident in Fukushima Daiichi nuclear power plants demonstrates the vulnerability of the currently operating nuclear power plants during the extended station blackout events. The objective of this paper is, considering the identified importance of the station blackout initiating event, to assess the implications of the strengthening of the SBO mitigation capability on safety of the NPP. The assessment is done with state-of-art deterministic and probabilistic methods and tolls with application on reference models of nuclear power plants. The U.S. NRC Station Blackout Rule describes procedure for the assessment of the size and capacity of the batteries in the nuclear power plant. The description of the procedure with the application on the reference plant and identified deficiencies in the procedure is presented. The safety analysis is done on reference model of the nuclear power plant. Obtained results show large

  5. Toward quantification of the uncertainty in estimating frequency of critical station blackout

    International Nuclear Information System (INIS)

    Rodgers, Shawn; Betancourt, Coral; Kee, Ernie; Nelson, Paul; Rodi, Paul

    2011-01-01

    A formal statement of the critical station blackout problem is provided, and a solution given, up to evaluation of an n-dimensional 'non recovery integral' n =number of trains (parallel backup sources of electrical power). Several approaches that have been developed in the industry to estimate probability of critical station blackout are shown to be interpretable as special cases of such integrals. Computational results, for a simple model problem, suggest there is yet a very substantial over conservatism in current state-of-the-art techniques for estimating probability of critical station blackout. Research issues associated to possibly meeting this need via computational evaluation of the non recovery integral are discussed. (author)

  6. Utilities respond to nuclear station blackout rule

    International Nuclear Information System (INIS)

    Rubin, A.M.; Beasley, B.; Tenera, L.P.

    1990-01-01

    The authors discuss how nuclear plants in the United States have taken actions to respond to the NRC Station Blackout Rule, 10CFR50.63. The rule requires that each light water cooled nuclear power plant licensed to operate must be able to withstand for a specified duration and recover from a station blackout. Station blackout is defined as the complete loss of a-c power to the essential and non-essential switch-gear buses in a nuclear power plant. A station blackout results from the loss of all off-site power as well as the on-site emergency a-c power system. There are two basic approaches to meeting the station blackout rule. One is to cope with a station blackout independent of a-c power. Coping, as it is called, means the ability of a plant to achieve and maintain a safe shutdown condition. The second approach is to provide an alternate a-c power source (AAC)

  7. Implications of Extension of Station Blackout Cooping Capability on Nuclear Power Plant Safety

    International Nuclear Information System (INIS)

    Volkanovski, Andrija

    2015-01-01

    The safety of the nuclear power plant depends on the availability of the continuous and reliable sources of electrical energy during all modes of operation of the plant. The station blackout corresponds to a total loss of all alternate current (AC) power as a result of complete failure of both offsite and on-site AC power sources. The electricity for the essential systems during station blackout is provided from the batteries installed in the nuclear power plant. The results of the probabilistic safety assessment show that station blackout is one of the main and frequently the dominant contributor to the core damage frequency. Results of the analysis of the implications of the strengthening of the SBO mitigation capability on safety of the NPP will be presented. The assessment is done with state-of-art deterministic and probabilistic methods and tolls with application on reference models of nuclear power plants. The safety analysis is done on reference model of the nuclear power plant. Obtained results show large decrease of the core damage frequency with strengthening of the station blackout mitigation capability. The time extension of blackout coping capability results in the delay of the core heat up for at least the extension time interval. Availability and operation of the steam driven auxiliary feedwater system maintains core integrity up to 72 h after the successful shutdown, even in the presence of the reactor coolant pumps seal leakage. The largest weighted decrease of the core damage frequency considering the costs for the modification is obtained for the modification resulting in extension of the station blackout coping capability. The importance of the common cause failures of the emergency diesel generators for the obtained decrease of the core damage frequency and overall safety of the plant is identified in the obtained results. (authors)

  8. Comparison of static model and dynamic model for the evaluation of station blackout sequences

    International Nuclear Information System (INIS)

    Lee, Kwang-Nam; Kang, Sun-Koo; Hong, Sung-Yull.

    1992-01-01

    Station blackout is one of major contributors to the core damage frequency (CDF) in many PSA studies. Since station blackout sequence exhibits dynamic features, accurate calculation of CDF for the station blackout sequence is not possible with event tree/fault tree (ET/FT) method. Although the integral method can determine accurate CDF, it is time consuming and is difficult to evaluate various alternative AC source configuration and sensitivities. In this study, a comparison is made between static model and dynamic model and a new methodology which combines static model and dynamic model is provided for the accurate quantification of CDF and evaluation of improvement alternatives. Results of several case studies show that accurate calculation of CDF is possible by introducing equivalent mission time. (author)

  9. Extended Station Blackout Analyses of an APR1400 with MARS-KS

    International Nuclear Information System (INIS)

    Kim, WoongBae; Jang, HyungWook; Oh, Seungjong; Lee, Sangyong

    2016-01-01

    The Fukushima Dai-ichi nuclear power plant accident shows that natural disasters such as earthquakes and the subsequent tsunamis can cause station blackout for several days. The electricity required for essential systems during a station blackout is provided from the emergency backup batteries installed at the nuclear power plant. In South Korea, in the event of an extended station blackout, the life of these emergency backup batteries has recently been extended from 8 hours to 24 hours at Shin-Kori 5, 6 and APR1400 for design certification. For a battery life of 24 hours, available safety means system, equipment and procedures are studied and analyzed in their ability to cope with an extended station blackout. A sensitivity study of reactor coolant pump seal leakage is performed to verify how different seal leakages could affect the system. For simulating of extended station blackout scenarios, the best estimate MARS-KS was used. In this paper, an APR1400 RELAP5 input deck was developed for station blackout scenario to analyze operation strategy by manually depressurizing the reactor coolant system through the steam generator's secondary side. Additionally, a sensitivity study was performed on reactor coolant pump seal leakage

  10. Extended Station Blackout Analyses of an APR1400 with MARS-KS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, WoongBae; Jang, HyungWook; Oh, Seungjong; Lee, Sangyong [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2016-10-15

    The Fukushima Dai-ichi nuclear power plant accident shows that natural disasters such as earthquakes and the subsequent tsunamis can cause station blackout for several days. The electricity required for essential systems during a station blackout is provided from the emergency backup batteries installed at the nuclear power plant. In South Korea, in the event of an extended station blackout, the life of these emergency backup batteries has recently been extended from 8 hours to 24 hours at Shin-Kori 5, 6 and APR1400 for design certification. For a battery life of 24 hours, available safety means system, equipment and procedures are studied and analyzed in their ability to cope with an extended station blackout. A sensitivity study of reactor coolant pump seal leakage is performed to verify how different seal leakages could affect the system. For simulating of extended station blackout scenarios, the best estimate MARS-KS was used. In this paper, an APR1400 RELAP5 input deck was developed for station blackout scenario to analyze operation strategy by manually depressurizing the reactor coolant system through the steam generator's secondary side. Additionally, a sensitivity study was performed on reactor coolant pump seal leakage.

  11. Extended station blackout analyses of an APR1400 with MARS-KS

    Directory of Open Access Journals (Sweden)

    Kim Woongbae

    2016-01-01

    Full Text Available The Fukushima Daiichi nuclear power plant accident shows that natural disasters such as earthquakes and the subsequent tsunamis can cause station blackout for several days. The electric energy required for essential systems during a station blackout is provided from emergency backup batteries installed at the nuclear power plant. In South Korea, in the event of an extended station blackout, the life of these emergency backup batteries has recently been extended from 8 hours to 24 hours at Shin-Kori 5, 6, and APR1400 for design certification. For a battery life of 24 hours, available safety means system, equipment and procedures are studied and analyzed in their ability to cope with an extended station blackout. A sensitivity study of reactor coolant pump seal leakage is performed to verify how different seal leakages could affect the system. For simulating extended station blackout scenarios, the best estimate MARS-KS computer code was used. In this paper, an APR1400 RELAP5 input deck was developed for station blackout scenario to analyze operation strategy by manually depressurizing the reactor coolant system through the steam generator's secondary side. Additionally, a sensitivity study on reactor coolant pump seal leakage was carried out.

  12. Safety aspects of station blackout at nuclear power plants

    International Nuclear Information System (INIS)

    1985-03-01

    The principal focus of this report is on existing light water reactor nuclear power plants. However, many of the considerations discussed herein can be equally applied to new plants, i.e. those not yet in construction. This report is organized to provide a description of design and procedural factors which safety assessments and reviews of operating experience have shown to be important. These are divided into the off-site power system, the on-site AC power systems and alternate (or nearby) sources of power. The latter may be used in the unlikely event that both normal off-site and on-site sources fail. It must be emphasized that first priority should be placed on designing and maintaining high reliability of both the off-site and on-site AC power systems. This basic concept also applies to the capabilities for restoring power sources which failed and making use of all available alternative and nearby power sources during an emergency, to restore AC power in a prompt manner. Discussions on these aspects are provided in chapters 2 and 3 of this report. Because the expected event frequency and associated confidence in such estimations of station blackout are uncertain, preparations should be made to deal with a station blackout. The nature of those preparations, whether they be optimizing emergency procedures to use existing equipment, modifying this equipment to enhance capabilities, or adding new components or systems to cope with station blackout, must be made in light of plant-specific assessments and regulatory safety philosophies/requirements. Discussions on these matters are provided in chapter 4. General and specific conclusions and recommendations are provided in chapter 5. Appendix A provides a description of several case studies on station blackout and loss of off-site power. Abstracts of papers and presentations are provided in Appendix B with authors and affiliations identified to facilitate personal contact. The References and Bibliography contain a

  13. Station blackout transient at the Browns Ferry Unit 1 Plant: a severe accident sequence analysis (SASA) program study

    International Nuclear Information System (INIS)

    Schultz, R.R.

    1982-01-01

    Operating plant transients are of great interest for many reasons, not the least of which is the potential for a mild transient to degenerate to a severe transient yielding core damage. Using the Browns Ferry (BF) Unit-1 plant as a basis of study, the station blackout sequence was investigated by the Severe Accident Sequence Analysis (SASA) Program in support of the Nuclear Regulatory Commission's Unresolved Safety Issue A-44: Station Blackout. A station blackout transient occurs when the plant's AC power from a comemrcial power grid is lost and cannot be restored by the diesel generators. Under normal operating conditions, f a loss of offsite power (LOSP) occurs [i.e., a complete severance of the BF plants from the Tennessee Valley Authority (TVA) power grid], the eight diesel generators at the three BF units would quickly start and power the emergency AC buses. Of the eight diesel generators, only six are needed to safely shut down all three units. Examination of BF-specific data show that LOSP frequency is low at Unit 1. The station blackout frequency is even lower (5.7 x 10 - 4 events per year) and hinges on whether the diesel generators start. The frequency of diesel generator failure is dictated in large measure by the emergency equipment cooling water (EECW) system that cools the diesel generators

  14. Design Provisions for Withstanding Station Blackout at Nuclear Power Plants

    International Nuclear Information System (INIS)

    2015-08-01

    International operating experience has shown that the loss of off-site power supply concurrent with a turbine trip and unavailability of the standby alternating current power system is a credible event. Lessons learned from the past and recent station blackout events, as well as the analysis of the safety margins performed as part of the ‘stress tests’ conducted on European nuclear power plants in response to the Fukushima Daiichi accident, have identified the station blackout event as a limiting case for most nuclear power plants. The magnitude 9.0 earthquake and consequential tsunami which occurred in Fukushima, Japan, in March 2011, led to a common cause failure of on-site alternating current electrical power supply systems at the Fukushima Daiichi nuclear power plant as well as the off-site power grid. In addition, the resultant flooding caused the loss of direct current power supply, which further exacerbated an already critical situation at the plant. The loss of electrical power resulted in the meltdown of the core in three reactors on the site and severely restricted heat removal from the spent fuel pools for an extended period of time. The plant was left without essential instrumentation and controls, and this made accident management very challenging for the plant operators. The operators attempted to bring and maintain the reactors in a safe state without information on the vital plant parameters until the power supply was eventually restored after several days. Although the Fukushima Daiichi accident progressed well beyond the expected consequences of a station blackout, which is the complete loss of all alternating current power supplies, many of the lessons learned from the accident are valid. A failure of the plant power supply system such as the one that occurred at Fukushima Daiichi represents a design extension condition that requires management with predesigned contingency planning and operator training. The extended loss of all power at a

  15. Station blackout at nuclear power plants: Radiological implications for nuclear war

    International Nuclear Information System (INIS)

    Shapiro, C.S.

    1986-12-01

    Recent work on station blackout is reviewed its radiological implications for a nuclear war scenario is explored. The major conclusion is that the effects of radiation from many nuclear weapon detonations in a nuclear war would swamp those from possible reactor accidents that result from station blackout

  16. Station blackout and public confidence: a cautionary tale

    International Nuclear Information System (INIS)

    Cave, L.

    1990-01-01

    The recent ''station blackout'' (ie loss of on-site and off-site AC power) incidents at the Vogtle PWR in the US and Hinkley Point B AGR in the Uk have led to further public concern about the safety of nuclear power, even though in each case the actual increase in the chance of an accident leading to a release of radioactivity to the environment was negligible. The industry may be wise to invest precautionary measures to reduce the frequency of such incidents and to increase public confidence. (author)

  17. Reactor coolant pump shaft seal stability during station blackout

    International Nuclear Information System (INIS)

    Rhodes, D.B.; Hill, R.C.; Wensel, R.G.

    1987-05-01

    Results are presented from an investigation into the behavior of Reactor Coolant Pump shaft seals during a potential station blackout (loss of all ac power) at a nuclear power plant. The investigation assumes loss of cooling to the seals and focuses on the effect of high temperature on polymer seals located in the shaft seal assemblies, and the identification of parameters having the most influence on overall hydraulic seal performance. Predicted seal failure thresholds are presented for a range of station blackout conditions and shaft seal geometries

  18. Reactor coolant pump shaft seal stability during station blackout

    Energy Technology Data Exchange (ETDEWEB)

    Rhodes, D B; Hill, R C; Wensel, R G

    1987-05-01

    Results are presented from an investigation into the behavior of Reactor Coolant Pump shaft seals during a potential station blackout (loss of all ac power) at a nuclear power plant. The investigation assumes loss of cooling to the seals and focuses on the effect of high temperature on polymer seals located in the shaft seal assemblies, and the identification of parameters having the most influence on overall hydraulic seal performance. Predicted seal failure thresholds are presented for a range of station blackout conditions and shaft seal geometries.

  19. Regulatory analysis for the resolution of Unresolved Safety Issue A-44, Station Blackout. Draft report

    International Nuclear Information System (INIS)

    Rubin, A.M.

    1986-01-01

    ''Station Blackout'' is the complete loss of alternating current (ac) electric power to the essential and nonessential buses in a nuclear power plant; it results when both offsite power and the onsite emergency ac power systems are unavailable. Because many safety systems required for reactor core decay heat removal and containment heat removal depend on ac power, the consequences of a station blackout could be severe. Because of the concern about the frequency of loss of offsite power, the number of failures of emergency diesel generators, and the potentially severe consequences of a loss of all ac power, ''Station Blackout'' was designated as Unresolved Safety Issue (USI) A-44. This report presents the regulatory analysis for USI A-44. It includes: (1) a summary of the issue, (2) the proposed technical resolution, (3) alternative resolutions considered by the Nuclear Regulatory Commission (NRC) staff, (4) an assessment of the benefits and costs of the recommended resolution, (5) the decision rationale, and (6) the relationship between USI A-44 and other NRC programs and requirements

  20. Evaluation of Station Blackout accidents at nuclear power plants. Technical findings related to Unresolved Safety Issue A-44. Draft report for comment

    International Nuclear Information System (INIS)

    Baranowsky, P.W.

    1985-05-01

    ''Station Blackout,'' which is the complete loss of alternating current (ac) electrical power in a nuclear power plant, has been designated as Unresolved Safety Issue A-44. Because many safety systems required for reactor core decay heat removal and containment heat removal depend on ac power, the consequences of a station blackout could be severe. This report documents the findings of technical studies performed as part of the program to resolve this issue. The important factors analyzed include: the frequency of loss of offsite power; the probability that emergency or onsite ac power supplies would be unavailable; the capability and reliability of decay heat removal systems independent of ac power; and the likelihood that offsite power would be restored before systems that cannot operate for extended periods without ac power fail, thus resulting in core damage. This report also addresses effects of different designs, locations, and operational features on the estimated frequency of core damage resulting from station blackout events

  1. Accident Analysis of Chinese CPR1000 in Response to Station Blackout

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Juyoul [FNC Technology Co., Yongin (Korea, Republic of); Cilliers, Anthonie [North-West University, Potchefstroom (South Africa)

    2016-10-15

    Stress tests required evaluation of the consequences of loss of safety functions from any initiating event (e.g., earthquake or flooding) causing loss of electrical power, including station blackout (SBO). The SBO scenario involves a loss of offsite power, failure of the redundant emergency diesel generators, failure of alternate current (AC) power restoration and the eventual degradation of the reactor coolant pump (RCP) seals resulting in a long term loss of coolant. Using PCTRAN/CPR1000, this study analyses the station blackout on a Chinese CPR1000 which is the most representative type reactor in terms of number of reactors, operating period, power capacity and geological distance from Korean Peninsula. Both the physical effects of the accidents as well as the releases of radioisotopes are calculated and discussed. Station blackout simulation was conducted in this study. The resulting effects seen are consistent with other stress test station blackout tests used utilizing licensed simulation codes. An exact comparison is however not possible as the plants on which the simulations was done vary greatly and the limitations of availability to Chinese FSAR. PCTRAN/CPR1000 is an extremely useful simulation package that provides engineers and scientists very accurate feedback to how a nuclear power plant would react as a whole under various plant conditions. It is able to do this extremely fast as well. As a training tool PCTRAN/CPR1000 provides hands-on experience with many of the primary plant operations and develops an intuitive understanding of the plant.

  2. Reactor coolant pump shaft seal behavior during station blackout

    International Nuclear Information System (INIS)

    Kittmer, C.A.; Wensel, R.G.; Rhodes, D.B.; Metcalfe, R.; Cotnam, B.M.; Gentili, H.; Mings, W.J.

    1985-04-01

    A testing program designed to provide fundamental information pertaining to the behavior of reactor coolant pump (RCP) shaft seals during a postulated nuclear power plant station blackout has been completed. One seal assembly, utilizing both hydrodynamic and hydrostatic types of seals, was modeled and tested. Extrusion tests were conducted to determine if seal materials could withstand predicted temperatures and pressures. A taper-face seal model was tested for seal stability under conditions when leaking water flashes to steam across the seal face. Test information was then used as the basis for a station blackout analysis. Test results indicate a potential problem with an elastomer material used for O-rings by a pump vendor; that vendor is considering a change in material specification. Test results also indicate a need for further research on the generic issue of RCP seal integrity and its possible consideration for designation as an unresolved safety issue

  3. Thermohydraulic status and component behavior in the PWR during the selected meltdown scenario station blackout (SBO); Thermohydraulisches Verhalten und Komponentenverhalten eines DWR bei ausgewaehltem Kernschmelzszenarium infolge Station Blackout (SBO). Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Band, Sebastian; Blaesius, Christoph; Scheuerer, Martina; Steinroetter, Thomas

    2017-09-15

    The report on the thermohydraulic status and component behavior in the PWR during the selected meltdown scenario station blackout (SBO) includes the following issues: status of science and technology on this topic, analysis of a high-pressure meltdown scenario using ATHLET-CD for a German PWR starting from the initiating event station blackout, three-dimensional computational fluid dynamic (CFD) analyses of the pressurizer coolant loop in a generic German PWR, evaluation of the thermohydraulic steam generator behavior and its effect on the involved primary circuit components.

  4. Comparative analysis of station blackout accident progression in typical PWR, BWR, and PHWR

    International Nuclear Information System (INIS)

    Park, Soo Young; Ahn, Kwang Il

    2012-01-01

    Since the crisis at the Fukushima plants, severe accident progression during a station blackout accident in nuclear power plants is recognized as a very important area for accident management and emergency planning. The purpose of this study is to investigate the comparative characteristics of anticipated severe accident progression among the three typical types of nuclear reactors. A station blackout scenario, where all off-site power is lost and the diesel generators fail, is simulated as an initiating event of a severe accident sequence. In this study a comparative analysis was performed for typical pressurized water reactor (PWR), boiling water reactor (BWR), and pressurized heavy water reactor (PHWR). The study includes the summarization of design differences that would impact severe accident progressions, thermal hydraulic/severe accident phenomenological analysis during a station blackout initiated-severe accident; and an investigation of the core damage process, both within the reactor vessel before it fails and in the containment afterwards, and the resultant impact on the containment.

  5. Probabilistic assessment of the Juragua NPP response under Station Blackout conditions

    International Nuclear Information System (INIS)

    Valhuerdi Debesa, C.; Vilaragut Llanes, J.J.

    1996-01-01

    Assessment of the NPP response under SBO (station Blackout) conditions is a current safety issue of special interest, In the case of Juragua NPP, the safety assessment related to this topic is very important, taking into account the peculiarities of the Cuban Electro energetic System: small and long island, without possibilities of conexion beyond its borders and under the incidence of tropical phenomena In this papers a preliminary evaluation is presented of the potential incidence of Station Blackout conditions for Juragua NPP. the importance of this sort of events for the safety of the plant is evaluated, the factors which condition it are identified and measures for its prevention or recovering the normal situation if such an event takes place are proposed

  6. Station blackout with reactor coolant pump seal leakage

    International Nuclear Information System (INIS)

    Evinay, A.

    1993-01-01

    The U.S. Nuclear Regulatory Commission (NRC) amended its regulations in 10CFR50 with the addition of a new section, 50.63, open-quotes Loss of All Alternating Current Power.close quotes The objective of these requirements is to ensure that all nuclear plants have the capability to withstand a station blackout (SBO) and maintain adequate reactor core cooling and containment integrity for a specified period of time. The NRC also issued Regulatory Guide (RG) 1.155, open-quotes Station Blackout,close quotes to provide guidance for meeting the requirements of 10CFR50.63. Concurrent with RG-1.155, the Nuclear Utility Management and Resources Council (NUMARC) has developed NUMARC 87-00 to address SBO-coping duration and capabilities at light water reactors. Licensees are required to submit a topical report based on NUMARC 87-00 guidelines, to demonstrate compliance with the SBO rule. One of the key compliance criteria is the ability of the plant to maintain adequate reactor coolant system (RCS) inventory to ensure core cooling for the required coping duration, assuming a leak rate of 25 gal/min per reactor coolant pump (RCP) seal in addition to technical specification (TS) leak rate

  7. The AP1000R nuclear power plant innovative features for extended station blackout mitigation

    International Nuclear Information System (INIS)

    Vereb, F.; Winters, J.; Schulz, T.; Cummins, E.; Oriani, L.

    2012-01-01

    Station Blackout (SBO) is defined as 'a condition wherein a nuclear power plant sustains a loss of all offsite electric power system concurrent with turbine trip and unavailability of all onsite emergency alternating current (AC) power system. Station blackout does not include the loss of available AC power to buses fed by station batteries through inverters or by alternate AC sources as defined in this section, nor does it assume a concurrent single failure or design basis accident...' in accordance with Reference 1. In this paper, the innovative features of the AP1000 plant design are described with their operation in the scenario of an extended station blackout event. General operation of the passive safety systems are described as well as the unique features which allow the AP1000 plant to cope for at least 7 days during station blackout. Points of emphasis will include: - Passive safety system operation during SBO - 'Fail-safe' nature of key passive safety system valves; automatically places the valve in a conservatively safe alignment even in case of multiple failures in all power supply systems, including normal AC and battery backup - Passive Spent Fuel Pool cooling and makeup water supply during SBO - Robustness of AP1000 plant due to the location of key systems, structures and components required for Safe Shutdown - Diverse means of supplying makeup water to the Passive Containment Cooling System (PCS) and the Spent Fuel Pool (SFP) through use of an engineered, safety-related piping interface and portable equipment, as well as with permanently installed onsite ancillary equipment. (authors)

  8. Transfer Effect Ratio of Loosely Coupled Coils for Wireless Power through CB Wall under Station Blackout(SBO)

    International Nuclear Information System (INIS)

    Koo, Kil Mo; Hong, Seong Wan; Song, Jin Ho; Baek, Won Pil; Cheon, Sang Hoon

    2016-01-01

    Instrumentations have had the bad situation like a station blackout(SBO) as the severe accident in nuclear power plants. In recent years, there has been an increasing interest in wireless power transfer technology, In particular, significant processing has been charted for inductively coupled systems. In this paper, we introduce some new method as transfer effect ratio of loosely coupled coils for wireless power through the CB(Container Building) wall as an alternative method under a station blackout of severe accident conditions in nuclear power plants. As an equivalent circuit model that can describe wireless energy transfer systems via coupled magnetic resonances for the CB thickness wall. The solution shows that the transmission efficiency can be decreased simply by adjusting the spacing between the power and the sending coils or between the receiving and the load coils. The system design can be calculated the frequency characteristics, and then an equivalent circuit model was developed from the node equation and established in an electric design automation tool

  9. Transfer Effect Ratio of Loosely Coupled Coils for Wireless Power through CB Wall under Station Blackout(SBO)

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Kil Mo; Hong, Seong Wan; Song, Jin Ho; Baek, Won Pil [KAERI, Daejeon (Korea, Republic of); Cheon, Sang Hoon [ETRI, Daejeon (Korea, Republic of)

    2016-05-15

    Instrumentations have had the bad situation like a station blackout(SBO) as the severe accident in nuclear power plants. In recent years, there has been an increasing interest in wireless power transfer technology, In particular, significant processing has been charted for inductively coupled systems. In this paper, we introduce some new method as transfer effect ratio of loosely coupled coils for wireless power through the CB(Container Building) wall as an alternative method under a station blackout of severe accident conditions in nuclear power plants. As an equivalent circuit model that can describe wireless energy transfer systems via coupled magnetic resonances for the CB thickness wall. The solution shows that the transmission efficiency can be decreased simply by adjusting the spacing between the power and the sending coils or between the receiving and the load coils. The system design can be calculated the frequency characteristics, and then an equivalent circuit model was developed from the node equation and established in an electric design automation tool.

  10. The AP1000{sup R} nuclear power plant innovative features for extended station blackout mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Vereb, F.; Winters, J.; Schulz, T.; Cummins, E.; Oriani, L. [Westinghouse Electric Company LLC, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2012-07-01

    Station Blackout (SBO) is defined as 'a condition wherein a nuclear power plant sustains a loss of all offsite electric power system concurrent with turbine trip and unavailability of all onsite emergency alternating current (AC) power system. Station blackout does not include the loss of available AC power to buses fed by station batteries through inverters or by alternate AC sources as defined in this section, nor does it assume a concurrent single failure or design basis accident...' in accordance with Reference 1. In this paper, the innovative features of the AP1000 plant design are described with their operation in the scenario of an extended station blackout event. General operation of the passive safety systems are described as well as the unique features which allow the AP1000 plant to cope for at least 7 days during station blackout. Points of emphasis will include: - Passive safety system operation during SBO - 'Fail-safe' nature of key passive safety system valves; automatically places the valve in a conservatively safe alignment even in case of multiple failures in all power supply systems, including normal AC and battery backup - Passive Spent Fuel Pool cooling and makeup water supply during SBO - Robustness of AP1000 plant due to the location of key systems, structures and components required for Safe Shutdown - Diverse means of supplying makeup water to the Passive Containment Cooling System (PCS) and the Spent Fuel Pool (SFP) through use of an engineered, safety-related piping interface and portable equipment, as well as with permanently installed onsite ancillary equipment. (authors)

  11. Pressurized-water-reactor station blackout

    International Nuclear Information System (INIS)

    Dobbe, C.A.

    1983-01-01

    The purpose of the Severe Accident Sequence Analysis (SASA) Program was to investigate accident scenarios beyond the design basis. The primary objective of SASA was to analyze nuclear plant transients that could lead to partial or total core melt and evaluate potential mitigating actions. The following summarizes the pressurized water reactor (PWR) SASA effort at the Idaho National Engineering Laboratory (INEL). The INEL is presently evaluating Unresolved Safety Issue A-44 - Station Blackout from initiation of the transient to core uncovery. The balance of the analysis from core uncovery until fission product release is being performed at Sandia National Laboratory (SNL). The current analyses involve the Bellefonte Nuclear Steam Supply System (NSSS), a Babcock and Wilcox (B and W) 205 Fuel Assembly (205-FA) raised loop design to be operated by the Tennessee Valley Authority

  12. Station blackout calculations for Peach Bottom

    International Nuclear Information System (INIS)

    Hodge, S.A.

    1985-01-01

    A calculational procedure for the Station Blackout Severe Accident Sequence at Browns Ferry Unit One has been repeated with plant-specific application to one of the Peach Bottom Units. The only changes required in code input are with regard to the primary continment concrete, the existence of sprays in the secondary containment, and the size of the refueling bay. Combustible gas mole fractions in the secondary containment of each plant during the accident sequence are determined. It is demonstrated why the current state-of-the-art corium/concrete interaction code is inadequate for application to the study of Severe Accident Sequences in plants with the BWR MK I or MK II containment design

  13. Analysis of a station blackout transient at the Kori units 3/4

    International Nuclear Information System (INIS)

    Bang, Young Seok; Kim, Hho Jung

    1992-01-01

    A transient analysis of station blackout accident is performed to evaluate the plant specific capability to cope with the accident at the Kori Units 3/4. The RELAP5/MOD3/5m5 code and full three loop modelling scheme are used in the calculation. The leak flow from reactor coolant system due to a failure of reactor coolant pump seal following the accident is assumed to be 25 gpm and the turbine driven aux feedwater unavailable. As a result, it is found that no core uncovery occurs in the plant until 7100 sec following a station blackout, the steam generator has a decay heat removal capability until 3100 sec, and the natural circulation over the reactor coolant loop until the complete loop seal voiding are observed. And the Nuclear Plant Analyzer is used and found to be effective in improving the phenomenological understanding on the accident

  14. Application of a steam injector for passive emergency core cooling during a station blackout

    International Nuclear Information System (INIS)

    Heinze, D.; Behnke, L.; Schulenberg, T.

    2012-01-01

    One of the basic protection targets of reactor safety is the safe heat removal during normal operation but also following shut-down. Since the reactor accident in Fukushima an optimization of the plant robustness in case of beyond-design accident is performed. Special attention is given to the increase of time available for starting appropriate measures for emergency core cooling in case of a station blackout. The state-of the art in engineering and research is presented. Investigations on the applicability of a steam injector for passive emergency core cooling during a station blackout in BWR-type reactors have progressed, experiments on dynamic behavior of the injector are described. A precise design with respect to the thermal hydraulic boundary conditions has been performed.

  15. Case study on the use of PSA methods: Station blackout risk at Millstone Unit 3

    International Nuclear Information System (INIS)

    1991-04-01

    In Westinghouse pressurized water reactors, severe accidents sequences resulting from station blackout have been recognized to be significant contributors to risk of core damage and public consequences. To properly quantify the risk of station blackout it is necessary to consider all possible types of core damage scenarios. Having obtained an accurate representation of the types of core damage scenarios involved specific areas of vulnerability can be pinpointed for further improvement. In performing this analysis it was decided to use time dependent probabilistic safety assessment method to provide a more realistic treatment of time dependent failure and recovery. Overview of the analysis, calculation procedures and methods, interpretation of the results are discussed. Peer review process is described. 13 refs, 19 figs

  16. Design Provisions for Station Blackout at Nuclear Power Plants

    International Nuclear Information System (INIS)

    Duchac, Alexander

    2015-01-01

    A station blackout (SBO) is generally known as 'a plant condition with complete loss of all alternating current (AC) power from off-site sources, from the main generator and from standby AC power sources important to safety to the essential and nonessential switchgear buses. Direct current (DC) power supplies and un-interruptible AC power supplies may be available as long as batteries can supply the loads. Alternate AC power supplies are available'. A draft Safety Guide DS 430 'Design of Electrical Power Systems for Nuclear Power Plants' provides recommendations regarding the implementation of Specific Safety Requirements: Design: Requirement 68 for emergency power systems. The Safety Guide outlines several design measures which are possible as a means of increasing the capability of the electrical power systems to cope with a station blackout, without providing detailed implementation guidance. A committee of international experts and advisors from numerous countries is currently working on an IAEA Technical Document (TECDOC) whose objective is to provide a common international technical basis from which the various criteria for SBO events need to be established, to support operation under design basis and design extension conditions (DEC) at nuclear power plants, to document in a comprehensive manner, all relevant aspects of SBO events at NPPs, and to outline critical issues which reflect the lessons learned from the Fukushima Dai-ichi accident. This paper discusses the commonly encountered difficulties associated with establishing the SBO criteria, shares the best practices, and current strategies used in the design and implementation of SBO provisions and outline the structure of the IAEA's SBO TECDOC under development. (author)

  17. The Fukushima Accident: A Station Blackout and the Consequences

    International Nuclear Information System (INIS)

    Schäfer, F.; Tusheva, P.; Kliem, S.

    2012-01-01

    Lessons learned from Fukushima: • Underestimation of the role of the natural hazards • Insufficient protection of the emergency power and service water systems • Protection of fuel assembly storage pools insufficient • Safety review for Station Blackout and seismic evaluation needed • Diverse power supply systems, diverse sources for water delivery • Role of passive safety systems, they must work in a real passive manner and without electricity to open valves • Backup systems for reactor parameters monitoring • Revision of Severe Accident Management Guidelines and countermeasures for specific “rare” events • Early/late phase operators’ actions / Effectiveness of the operators’ actions

  18. Uncertainties in source term estimates for a station blackout accident in a BWR with Mark I containment

    International Nuclear Information System (INIS)

    Lee, M.; Cazzoli, E.; Liu, Y.; Davis, R.; Nourbakhsh, H.; Schmidt, E.; Unwin, S.; Khatib-Rahbar, M.

    1988-01-01

    In this paper, attention is limited to a single accident progression sequence, namly a station blackout accident in a BWR with a Mark I containment building. Identified as an important accident in the draft version of NUREG-1150 a station blackout involves loss of both off-site power and dc power resulting in failure of the diesels to start and in the unavailability of the high pressure injection and core isolation cooling systems. This paper illustrates the calculated uncertainties (Probability Density Functions) associated with the radiological releases into the environment for the nine fission product groups at 10 hours following the initiation of core-concrete interactions. Also shown are the results ofthe STCP base case simulation. 5 refs., 1 fig., 1 tab

  19. Comparison of the MAAP4 code with the station blackout simulation in the IIST facility

    International Nuclear Information System (INIS)

    Robert E Henry; Christopher E Henry; Chan Y Paik; George M Hauser

    2005-01-01

    Full text of publication follows: The Modular Accident Analysis Program (MAAP) is an integral system model to assess challenges to the reactor core, Reactor Coolant System (RCS) and containment for accident conditions. MAAP4 is the current version used by the MAAP Users Group to assess the responses to a spectrum of accident conditions. Benchmarking of the MAAP code with integral system experiments has been a continuing effort by MAAP developers and users. Several of these have been configured into dynamic benchmarks and are included in Volume III (Benchmarking) of the MAAP4 Users Manual (EPRI, 2004). One such integral experiment is the INER integral system test (IIST) constructed at the Institute of Nuclear Energy Research in Taiwan. This experimental facility is a reduced height, reduced pressure representation of a 3-loop PWR and has been used to examine several different types of accident sequences. One of these is a station blackout simulation with loss of auxiliary feedwater at the time that the transient is initiated. This is an important integral experiment to be compared with the MAAP4 code models. A parameter file (those values representing the system design and boundary experimental conditions) has been developed for the IIST facility and an input deck has been configured to represent a station blackout sequence with instantaneous loss of auxiliary feedwater. Of importance in this benchmark is (a) the rate at which the secondary side inventory is depleted, (b) the depletion of water within the reactor pressure vessel and (c) the time at which the top of the reactor core is uncovered. Comparisons have been made with these three different intervals and there is good agreement between the timing of these events for the MAAP4 benchmark. This is important since this reference sequence represents a set of boundary conditions that is continually with subsequent analyses being perturbations on this type of accident sequence. The good agreement between MAAP4 and

  20. Relap5 Analysis of Processes in Reactor Cooling Circuit and Reactor Cavity in Case of Station Blackout in RBMK-1500

    International Nuclear Information System (INIS)

    Kaliatka, A.

    2007-01-01

    Ignalina NPP is equipped with channel-type boiling-water graphite-moderated reactor RBMK-1500. Results of the level-1 probabilistic safety assessment of the Ignalina NPP have shown that in topography of the risk, the transients with failure of long-term core cooling other than LOCA are the main contributors to the core damage frequency. The total loss of off-site power with a failure to start any diesel generator, that is station blackout, is the event which could lead to the loss of long-term core cooling. Such accident could lead to multiple ruptures of fuel channels with severe consequences and should be analyzed in order to estimate the timing of the key events and the possibilities for accident management. This paper presents the results of the analysis of station blackout at Ignalina NPP. Analysis was performed using thermal-hydraulic state-of-the-art RELAP5/MOD3.2 code. The response of reactor cooling system and the processes in the reactor cavity and its venting system in case of a few fuel-channel ruptures due to overheating were demonstrated. The possible measures for prevention of the development of this beyond design basis accident (BDBA) to a severe accident are discussed

  1. PWR station blackout transient simulation in the INER integral system test facility

    International Nuclear Information System (INIS)

    Liu, T.J.; Lee, C.H.; Hong, W.T.; Chang, Y.H.

    2004-01-01

    Station blackout transient (or TMLB' scenario) in a pressurized water reactor (PWR) was simulated using the INER Integral System Test Facility (IIST) which is a 1/400 volumetrically-scaled reduce-height and reduce-pressure (RHRP) simulator of a Westinghouse three-loop PWR. Long-term thermal-hydraulic responses including the secondary boil-off and the subsequent primary saturation, pressurization and core uncovery were simulated based on the assumptions of no offsite and onsite power, feedwater and operator actions. The results indicate that two-phase discharge is the major depletion mode since it covers 81.3% of the total amount of the coolant inventory loss. The primary coolant inventory has experienced significant re-distribution during a station blackout transient. The decided parameter to avoid the core overheating is not the total amount of the coolant inventory remained in the primary core cooling system but only the part of coolant left in the pressure vessel. The sequence of significant events during transient for the IIST were also compared with those of the ROSA-IV large-scale test facility (LSTF), which is a 1/48 volumetrically-scaled full-height and full-pressure (FHFP) simulator of a PWR. The comparison indicates that the sequence and timing of these events during TMLB' transient studied in the RHRP IIST facility are generally consistent with those of the FHFP LSTF. (author)

  2. Station Blackout Analysis of HTGR-Type Experimental Power Reactor

    Science.gov (United States)

    Syarip; Zuhdi, Aliq; Falah, Sabilul

    2018-01-01

    The National Nuclear Energy Agency of Indonesia has decided to build an experimental power reactor of high-temperature gas-cooled reactor (HTGR) type located at Puspiptek Complex. The purpose of this project is to demonstrate a small modular nuclear power plant that can be operated safely. One of the reactor safety characteristics is the reliability of the reactor to the station blackout (SBO) event. The event was observed due to relatively high disturbance frequency of electricity network in Indonesia. The PCTRAN-HTR functional simulator code was used to observe fuel and coolant temperature, and coolant pressure during the SBO event. The reactor simulated at 10 MW for 7200 s then the SBO occurred for 1-3 minutes. The analysis result shows that the reactor power decreases automatically as the temperature increase during SBO accident without operator’s active action. The fuel temperature increased by 36.57 °C every minute during SBO and the power decreased by 0.069 MW every °C fuel temperature rise at the condition of anticipated transient without reactor scram. Whilst, the maximum coolant (helium) temperature and pressure are 1004 °C and 9.2 MPa respectively. The maximum fuel temperature is 1282 °C, this value still far below the fuel temperature limiting condition i.e. 1600 °C, its mean that the HTGR has a very good inherent safety system.

  3. PSB-VVER experimental and analytical investigation of station blackout accident in VVER-1000

    Energy Technology Data Exchange (ETDEWEB)

    Lipatov, I.A.; Kapustin, A.V.; Nikonov, S.M.; Rovnov, A.A.; Basov, A.V. [Electrogorsk Research and Engineering Centre (EREC), Moscow Region (Russian Federation); Elkin, I.V. [NSI RRC, Kurchatov Institute, Moscow (Russian Federation)

    2007-07-01

    In November 2003, an experiment simulating station blackout accident was carried out in the PSB-VVER integral test facility at the Electrogorsk Research and Engineering Centre (Russia). The purpose of the experiment was to provide missing data for code validation as well as to investigate the VVER thermohydraulics in the blackout conditions. The experiment covers a wide range of phenomena relating not only to transients but also to small break loss-of-coolant accidents. The data gained in the test has been used to assess the RELAP5/MOD3.3 code. In this paper, a special attention has been paid to the code assessment regarding the mixture level and entrainment in steam generator secondary side. The analysis of the recorded transient has shown that the calculation of the heat transfer on the secondary side of steam generators is very sensitive to the steam generator nodalization. (authors)

  4. Probabilistic assessment of Juragua Nuclear Power Plant response under station blackout conditions

    International Nuclear Information System (INIS)

    Valhuerdi, C.; Vilaragut, J.J.; Perdomo, M.; Torres, A.

    1995-01-01

    The preliminary results concerning the response of station blackout are shown in this paper. These results have been obtained in the framework of initiator lass of external electrical supply as a aport of the revision o of the current probabilistic safety analysis. The work is also based on the results reported in the thermohydraulic calculations of VVER 440 plants responses under these conditions and the experience of this type of notified incidents. Finally, a comparative analysis with the results obtained for other reactor technologies is presented

  5. Thermohydraulic and safety analysis on China advanced research reactor under station blackout accident

    International Nuclear Information System (INIS)

    Tian Wenxi; Qiu Suizheng; Su Guanghui; Jia Dounan; Liu Xingmin; Zhang Jianwei

    2007-01-01

    A thermohydraulic and safety analysis code-TSACC has been developed using Fortran90 language to evaluate the transient thermohydraulic behavior of the China advanced research reactor (CARR) under station blackout accident (SBA). For the development of TSACC, a series of corresponding mathematical and physical models were applied. Point reactor neutron kinetics model was adopted for solving the reactor power. All possible flow and heat transfer conditions under station blackout accident were considered and the optional correlations were supplied. The usual finite difference method was abandoned and the integral technique was adopted to evaluate the temperature field of the plate type fuel elements. A new simple and convenient equation was proposed for the resolution of the transient behaviors of the main pump instead of the complicated four-quadrant model. Gear method and Adams method were adopted alternately for a better solution to the stiff differential equations describing the dynamic behavior of the CARR. The computational result of TSACC showed the adequacy of the safety margin of CARR under SBA. For the purpose of Verification and Validation (V and V), the simulated results of TSACC were compared with those of RELAP5/MOD3 and a good agreement was obtained. The adoption of modular programming techniques enables TASCC to be applied to other reactors by easily modifying the corresponding function modules

  6. Analysis of Peach Bottom station blackout with MELCOR

    International Nuclear Information System (INIS)

    Dingman, S.E.; Cole, R.K.; Haskin, F.E.; Summers, R.M.; Webb, S.W.

    1987-01-01

    A demonstration analysis of station blackout at Peach Bottom has been performed using MELCOR and the results have been compared with those from MARCON 2.1B and the Source Term Code Package (STCP). MELCOR predicts greater in-vessel hydrogen production, earlier melting and core collapse, but later debris discharge than MARCON 2.1B. The drywell fails at vessel breach in MELCOR, but failure is delayed about an hour in MARCON 2.1B. These differences are mainly due to the MELCOR models for candling during melting, in-core axial conduction, and continued oxidation and heat transfer from core debris following lower head dryout. Three sensitivity calculations have been performed with MELCOR to address uncertainties regarding modeling of the core-concrete interactions. The timing of events and the gas and radionuclide release rates are somewhat different in the base case and the three sensitivity cases, but the final conditions and total releases are similar

  7. Analysis of hot leg natural circulation under station blackout severe accident

    International Nuclear Information System (INIS)

    Deng Jian; Cao Xuewu

    2007-01-01

    Under severe accidents, natural circulation flows are important to influence the accident progression and result in a pressurized water reactor (PWR). In a station blackout accident with no recovery of steam generator (SG) auxiliary feedwater (TMLB' severe accident scenario), the hot leg countercurrent natural circulation flow is analyzed by using a severe-accident code, to better understand its potential impacts on the creep-rupture timing among the surge line, the hot leg; and SG tubes. The results show that the natural circulation may delay the failure time of the hot leg. The recirculation ratio and the hot mixing factor are also calculated and discussed. (authors)

  8. Investigation of station blackout scenario in VVER440/v230 with RELAP5 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Gencheva, Rositsa Veselinova, E-mail: roseh@mail.bg; Stefanova, Antoaneta Emilova, E-mail: antoanet@inrne.bas.bg; Groudev, Pavlin Petkov, E-mail: pavlinpg@inrne.bas.bg

    2015-12-15

    Highlights: • We have modeled SBO in VVER440. • RELAP5/MOD3 computer code has been used. • Base case calculation has been done. • Fail case calculation has been done. • Operator and alternative operator actions have been investigated. - Abstract: During the development of symptom-based emergency operating procedures (SB-EOPs) for VVER440/v230 units at Kozloduy Nuclear Power Plant (NPP) a number of analyses have been performed using the RELAP5/MOD3 (Carlson et al., 1990). Some of them investigate the response of VVER440/v230 during the station blackout (SBO). The main purpose of the analyses presented in this paper is to identify the behavior of important VVER440 parameters in case of total station blackout. The RELAP5/MOD3 has been used to simulate the SBO in VVER440 NPP model (Fletcher and Schultz, 1995). This model was developed at the Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences (INRNE-BAS), Sofia, for analyses of operational occurrences, abnormal events and design based scenarios. The model provides a significant analytical capability for specialists working in the field of NPP safety.

  9. Investigation of accident management procedures related to loss of feedwater and station blackout in PSB-VVER integral test facility

    Energy Technology Data Exchange (ETDEWEB)

    Bucalossi, A. [EC JRC, (JRC F.5) PO Box 2, 1755 ZG Petten (Netherlands); Del Nevo, A., E-mail: alessandro.delnevo@enea.it [ENEA, C.R. Brasimone, 40032 Camugnano (Italy); Moretti, F.; D' Auria, F. [GRNSPG, Universita di Pisa, via Diotisalvi 2, 56100 Pisa (Italy); Elkin, I.V.; Melikhov, O.I. [Electrogorsk Research and Engineering Centre, Electrogorsk, Moscow Region (Russian Federation)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer Four integral test facility experiments related to VVER-1000 reactor. Black-Right-Pointing-Pointer TH response of the VVER-1000 primary system following total loss of feedwater and station blackout scenarios. Black-Right-Pointing-Pointer Accident management procedures in case of total loss of feedwater and station blackout. Black-Right-Pointing-Pointer Experimental data represent an improvement of existing database for TH code validation. - Abstract: VVER 1000 reactors have some unique and specific features (e.g. large primary and secondary side fluid inventory, horizontal steam generators, core design) that require dedicated experimental and analytical analyses in order to assess the performance of safety systems and the effectiveness of possible accident management strategies. The European Commission funded project 'TACIS 2.03/97', Part A, provided valuable experimental data from the large-scale (1:300) PSB-VVER test facility, investigating accident management procedures in VVER-1000 reactor. A test matrix was developed at University of Pisa (responsible of the project) with the objective of obtaining the experimental data not covered by the OECD VVER validation matrix and with main focus on accident management procedures. Scenarios related to total loss of feed water and station blackout are investigated by means of four experiments accounting for different countermeasures, based on secondary cooling strategies and primary feed and bleed procedures. The transients are analyzed thoroughly focusing on the identification of phenomena that will challenge the code models during the simulations.

  10. Plant habitability assessment for Point Lepreau Generating Station during a severe accident resulting from station blackout conditions

    International Nuclear Information System (INIS)

    Mullin, D.

    2015-01-01

    In response to the CNSC Fukushima Action Plan, the CANDU Owners Group (COG) developed a methodology for assessing nuclear power plant habitability under Joint Project 4426 and to determine if any improvement actions are necessary to provide a high degree of assurance that a severe accident can be managed from a human and organizational performance perspective. NB Power has applied the methodology considering a station black-out scenario (representative case), and assessed the effects of non-radiological hazards and radiological hazards in the context of operator dose relative to emergency dose limits. The paper will discuss the overall methodology, findings and recommendations. (author)

  11. Plant habitability assessment for Point Lepreau Generating Station during a severe accident resulting from station blackout conditions

    Energy Technology Data Exchange (ETDEWEB)

    Mullin, D., E-mail: dmullin@nbpower.com [New Brunswick Power Corporation, Point Lepreau Generating Station, Lepreau, NB (Canada)

    2015-07-01

    In response to the CNSC Fukushima Action Plan, the CANDU Owners Group (COG) developed a methodology for assessing nuclear power plant habitability under Joint Project 4426 and to determine if any improvement actions are necessary to provide a high degree of assurance that a severe accident can be managed from a human and organizational performance perspective. NB Power has applied the methodology considering a station black-out scenario (representative case), and assessed the effects of non-radiological hazards and radiological hazards in the context of operator dose relative to emergency dose limits. The paper will discuss the overall methodology, findings and recommendations. (author)

  12. Analysis of economics and safety to cope with station blackout in PWR

    International Nuclear Information System (INIS)

    Al Shehhi, Ahmed Saeed; Chang, Soon Heung; Kim, Sang Ho; Kang, Hyun Gook

    2013-01-01

    Highlights: • Proposed framework covers all aspects of very complicated decision making. • We addressed the various options against SBO. • Emergency water supply through the steam generator hookup was considered. • Optimal testing interval of EDG was determined in various design options. • Effect of risk aversion factor on decision making was quantitatively illustrated. - Abstract: Design and operation options that can reduce both the initiating event frequency and the accident mitigation probability were addressed in an integrated framework to cope with station blackout. The safety, engineering cost, water delivery cost and testing/maintenance cost of each option were quantitatively evaluated to calculate the cost variation and to find an optimal point in the reference reactor, OPR1000. Design variables that represent additional emergency water supply, diverse emergency diesel generator, and surveillance test period modification were investigated. Based on these design variables, we applied the developed formula to quantify cost items, which were presented as changes of the economics and the safety. A case study was provided to illustrate the change of the total cost. Different risk aversion factors that represent different attitudes of the public were also investigated. The result shows that the costs and benefits of various complicated options can be effectively addressed with the proposed risk-informed decision making framework

  13. Uncertainty and sensitivity analysis for the simulation of a station blackout scenario in the Jules Horowitz Reactor

    International Nuclear Information System (INIS)

    Ghione, Alberto; Noel, Brigitte; Vinai, Paolo; Demazière, Christophe

    2017-01-01

    Highlights: • A station blackout scenario in the Jules Horowitz Reactor is analyzed using CATHARE. • Input and model uncertainties relevant to the transient, are considered. • A statistical methodology for the propagation of the uncertainties is applied. • No safety criteria are exceeded and sufficiently large safety margins are estimated. • The most influential uncertainties are determined with a sensitivity analysis. - Abstract: An uncertainty and sensitivity analysis for the simulation of a station blackout scenario in the Jules Horowitz Reactor (JHR) is presented. The JHR is a new material testing reactor under construction at CEA on the Cadarache site, France. The thermal-hydraulic system code CATHARE is applied to investigate the response of the reactor system to the scenario. The uncertainty and sensitivity study was based on a statistical methodology for code uncertainty propagation, and the ‘Uncertainty and Sensitivity’ platform URANIE was used. Accordingly, the input uncertainties relevant to the transient, were identified, quantified, and propagated to the code output. The results show that the safety criteria are not exceeded and sufficiently large safety margins exist. In addition, the most influential input uncertainties on the safety parameters were found by making use of a sensitivity analysis.

  14. Development and qualification of a thermal-hydraulic nodalization for modeling station blackout accident in PSB-VVER test facility

    Energy Technology Data Exchange (ETDEWEB)

    Saghafi, Mahdi [Department of Energy Engineering, Sharif University of Technology, Azadi Avenue, Tehran (Iran, Islamic Republic of); Ghofrani, Mohammad Bagher, E-mail: ghofrani@sharif.edu [Department of Energy Engineering, Sharif University of Technology, Azadi Avenue, Tehran (Iran, Islamic Republic of); D’Auria, Francesco [San Piero a Grado Nuclear Research Group (GRNSPG), University of Pisa, Via Livornese 1291, San Piero a Grado, Pisa (Italy)

    2016-07-15

    Highlights: • A thermal-hydraulic nodalization for PSB-VVER test facility has been developed. • Station blackout accident is modeled with the developed nodalization in MELCOR code. • The developed nodalization is qualified at both steady state and transient levels. • MELCOR predictions are qualitatively and quantitatively in acceptable range. • Fast Fourier Transform Base Method is used to quantify accuracy of code predictions. - Abstract: This paper deals with the development of a qualified thermal-hydraulic nodalization for modeling Station Black-Out (SBO) accident in PSB-VVER Integral Test Facility (ITF). This study has been performed in the framework of a research project, aiming to develop an appropriate accident management support tool for Bushehr nuclear power plant. In this regard, a nodalization has been developed for thermal-hydraulic modeling of the PSB-VVER ITF by MELCOR integrated code. The nodalization is qualitatively and quantitatively qualified at both steady-state and transient levels. The accuracy of the MELCOR predictions is quantified in the transient level using the Fast Fourier Transform Base Method (FFTBM). FFTBM provides an integral representation for quantification of the code accuracy in the frequency domain. It was observed that MELCOR predictions are qualitatively and quantitatively in the acceptable range. In addition, the influence of different nodalizations on MELCOR predictions was evaluated and quantified using FFTBM by developing 8 sensitivity cases with different numbers of control volumes and heat structures in the core region and steam generator U-tubes. The most appropriate case, which provided results with minimum deviations from the experimental data, was then considered as the qualified nodalization for analysis of SBO accident in the PSB-VVER ITF. This qualified nodalization can be used for modeling of VVER-1000 nuclear power plants when performing SBO accident analysis by MELCOR code.

  15. Large blackouts in North America: Historical trends and policy implications

    International Nuclear Information System (INIS)

    Hines, Paul; Apt, Jay; Talukdar, Sarosh

    2009-01-01

    Using data from the North American Electric Reliability Council (NERC) for 1984-2006, we find several trends. We find that the frequency of large blackouts in the United States has not decreased over time, that there is a statistically significant increase in blackout frequency during peak hours of the day and during late summer and mid-winter months (although non-storm-related risk is nearly constant through the year) and that there is strong statistical support for the previously observed power-law statistical relationship between blackout size and frequency. We do not find that blackout sizes and blackout durations are significantly correlated. These trends hold even after controlling for increasing demand and population and after eliminating small events, for which the data may be skewed by spotty reporting. Trends in blackout occurrences, such as those observed in the North American data, have important implications for those who make investment and policy decisions in the electricity industry. We provide a number of examples that illustrate how these trends can inform benefit-cost analysis calculations. Also, following procedures used in natural disaster planning we use the observed statistical trends to calculate the size of the 100-year blackout, which for North America is 186,000 MW.

  16. The Safety Assessment of OPR-1000 for Station Blackout Applying Combined Deterministic and Probabilistic Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dong Gu; Ahn, Seung-Hoon; Cho, Dae-Hyung [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-05-15

    This is termed station blackout (SBO). However, it does not generally include the loss of available AC power to safety buses fed by station batteries through inverters or by alternate AC sources. Historically, risk analysis results have indicated that SBO was a significant contributor to overall core damage frequency. In this study, the safety assessment of OPR-1000 nuclear power plant for SBO accident, which is a typical beyond design basis accident and important contributor to overall plant risk, is performed by applying the combined deterministic and probabilistic procedure (CDPP). In addition, discussions are made for reevaluation of SBO risk at OPR-1000 by eliminating excessive conservatism in existing PSA. The safety assessment of OPR-1000 for SBO accident, which is a typical BDBA and significant contributor to overall plant risk, was performed by applying the combined deterministic and probabilistic procedure. However, the reference analysis showed that the CDF and CCDP did not meet the acceptable risk, and it was confirmed that the SBO risk should be reevaluated. By estimating the offsite power restoration time appropriately, the SBO risk was reevaluated, and it was finally confirmed that current OPR-1000 system lies in the acceptable risk against the SBO. In addition, it was demonstrated that the proposed CDPP is applicable to safety assessment of BDBAs in nuclear power plants without significant erosion of the safety margin.

  17. Cooling methods of station blackout scenario for LWR plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    The objective of this study is to analyze the cooling method of station blackout scenario for both the BWR and PWR plants by RELAP5 code and to check the validity of the cooling method proposed by the utilities. In the BWR plant cooling scenario, the Reactor Core Isolation Cooling System (RCIC), which is operated with high pressure steam from the reactor, injects cooling water into the reactor to keep the core water level. The steam generated in the core is released into the suppression pool at containment vessel to condense. To restrict the containment vessel pressure rising, the ventilation from the wet-well is operated. The scenario is analyzed by RELAP5 code. In the PWR plant scenario, the primary pressure is decreased by the turbine-driven auxiliary feed water system operated with secondary side steam of the steam generators (SGs). And the core cooling is kept by the natural circulation flow at the primary loop. From the RELAP5 code analysis, it was shown that the primary system cooling was practicable by using the turbine-driven auxiliary feed water system. (author)

  18. Cooling methods of station blackout scenario for LWR plants

    International Nuclear Information System (INIS)

    2012-01-01

    The objective of this study is to analyze the cooling method of station blackout scenario for both the BWR and PWR plants by RELAP5 code and to check the validity of the cooling method proposed by the utilities. In the BWR plant cooling scenario, the Reactor Core Isolation Cooling System (RCIC), which is operated with high pressure steam from the reactor, injects cooling water into the reactor to keep the core water level. The steam generated in the core is released into the suppression pool at containment vessel to condense. To restrict the containment vessel pressure rising, the ventilation from the wet-well is operated. The scenario is analyzed by RELAP5 and CONTEMPT-LT code. In the PWR plant scenario, the primary pressure is decreased by the turbine-driven auxiliary feed water system operated with secondary side steam of the steam generators (SGs). And the core cooling is kept by the natural circulation flow at the primary loop. The analytical method of un-uniform flow behavior among the SG U-tubes, which affects the natural circulation flow rate, is developed. (author)

  19. Demonstration of fully coupled simplified extended station black-out accident simulation with RELAP-7

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Anders, David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, Richard [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-10-01

    The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The RELAP-7 code develop-ment effort started in October of 2011 and by the end of the second development year, a number of physical components with simplified two phase flow capability have been de-veloped to support the simplified boiling water reactor (BWR) extended station blackout (SBO) analyses. The demonstration case includes the major components for the primary system of a BWR, as well as the safety system components for the safety relief valve (SRV), the reactor core isolation cooling (RCIC) system, and the wet well. Three scenar-ios for the SBO simulations have been considered. Since RELAP-7 is not a severe acci-dent analysis code, the simulation stops when fuel clad temperature reaches damage point. Scenario I represents an extreme station blackout accident without any external cooling and cooling water injection. The system pressure is controlled by automatically releasing steam through SRVs. Scenario II includes the RCIC system but without SRV. The RCIC system is fully coupled with the reactor primary system and all the major components are dynamically simulated. The third scenario includes both the RCIC system and the SRV to provide a more realistic simulation. This paper will describe the major models and dis-cuss the results for the three scenarios. The RELAP-7 simulations for the three simplified SBO scenarios show the importance of dynamically simulating the SRVs, the RCIC sys-tem, and the wet well system to the reactor safety during extended SBO accidents.

  20. MELCOR simulation of long-term station blackout at Peach Bottom

    International Nuclear Information System (INIS)

    Madni, I.K.

    1990-01-01

    This paper presents the results from MELCOR (Version 1.8BC) calculations of the Long-Term Station Blackout Accident Sequence, with failure to depressurize the reactor vessel, at the Peach Bottom (BWR Mark I) plant, and presents comparisons with Source Term Code Package (STCP) calculations of the same sequence. This sequence assumes that batteries are available for six hours following loss of all power to the plant. Following battery failure, the reactor coolant system (RCS) inventory is boiled off through the relief valves by continued decay heat generation. This leads to core uncovery, heatup, clad oxidation, core degradation, relocation, and, eventually, vessel failure at high pressure. STCP has calculated the transient out to 13.5 hours after core uncovery. The results include the timing of key events, pressure and temperature response in the reactor vessel and containment, hydrogen production, and the release of source terms to the environment. 12 refs., 23 figs., 3 tabs

  1. Hypersonic Cruise and Re-Entry Radio Frequency Blackout Mitigation: Alleviating the Communications Blackout Problem

    Science.gov (United States)

    Manning, Robert M.

    2017-01-01

    The work presented here will be a review of a NASA effort to provide a method to transmit and receive RF communications and telemetry through a re-entry plasma thus alleviating the classical RF blackout phenomenon.

  2. Analysis of station blackout accidents for the Bellefonte pressurized water reactor

    International Nuclear Information System (INIS)

    Gasser, R.D.; Bieniarz, P.P.; Tills, J.L.

    1986-09-01

    An analysis has been performed for the Bellefonte PWR Unit 1 to determine the containment loading and the radiological releases into the environment from a station blackout accident. A number of issues have been addressed in this analysis which include the effects of direct heating on containment loading, and the effects of fission product heating and natural convection on releases from the primary system. The results indicate that direct heating which involves more than about 50% of the core can fail the Bellefonte containment, but natural convection in the RCS may lead to overheating and failure of the primary system piping before core slump, thus, eliminating or mitigating direct heating. Releases from the primary system are significantly increased before vessel breach due to natural circulation and after vessel breach due to reevolution of retained fission products by fission product heating of RCS structures

  3. Analysis of Radio Frequency Blackout for a Blunt-Body Capsule in Atmospheric Reentry Missions

    Directory of Open Access Journals (Sweden)

    Yusuke Takahashi

    2016-01-01

    Full Text Available A numerical analysis of electromagnetic waves around the atmospheric reentry demonstrator (ARD of the European Space Agency (ESA in an atmospheric reentry mission was conducted. During the ARD mission, which involves a 70% scaled-down configuration capsule of the Apollo command module, radio frequency blackout and strong plasma attenuation of radio waves in communications with data relay satellites and air planes were observed. The electromagnetic interference was caused by highly dense plasma derived from a strong shock wave generated in front of the capsule because of orbital speed during reentry. In this study, the physical properties of the plasma flow in the shock layer and wake region of the ESA ARD were obtained using a computational fluid dynamics technique. Then, electromagnetic waves were expressed using a frequency-dependent finite-difference time-domain method using the plasma properties. The analysis model was validated based on experimental flight data. A comparison of the measured and predicted results showed good agreement. The distribution of charged particles around the ESA ARD and the complicated behavior of electromagnetic waves, with attenuation and reflection, are clarified in detail. It is suggested that the analysis model could be an effective tool for investigating radio frequency blackout and plasma attenuation in radio wave communication.

  4. Main considerations for modelling a station blackout scenario with trace

    International Nuclear Information System (INIS)

    Querol, Andrea; Turégano, Jara; Lorduy, María; Gallardo, Sergio; Verdú, Gumersindo

    2017-01-01

    In the nuclear safety field, the thermal hydraulic phenomena that take place during an accident in a nuclear power plant is of special importance. One of the most studied accidents is the Station BlackOut (SBO). The aim of the present work is the analysis of the PKL integral test facility nodalization using the thermal-hydraulic code TRACE5 to reproduce a SBO accidental scenario. The PKL facility reproduces the main components of the primary and secondary systems of its reference nuclear power plant (Philippsburg II). The results obtained with different nodalization have been compared: 3D vessel vs 1D vessel, Steam Generator (SG) modelling using PIPE or TEE components and pressurizer modelling with PIPE or PRIZER components. Both vessel nodalization (1D vessel and 3D vessel) reproduce the physical phenomena of the experiment. However, there are significant discrepancies between them. The appropriate modelling of the SG is also relevant in the results. Regarding the other nodalization (PIPE or TEE components for SG and PIPE or PRIZER components for pressurizer), do not produce relevant differences in the results. (author)

  5. Main considerations for modelling a station blackout scenario with trace

    Energy Technology Data Exchange (ETDEWEB)

    Querol, Andrea; Turégano, Jara; Lorduy, María; Gallardo, Sergio; Verdú, Gumersindo, E-mail: anquevi@upv.es, E-mail: jaturna@upv.es, E-mail: maloral@upv.es, E-mail: sergalbe@iqn.upv.es, E-mail: gverdu@iqn.upv.es [Instituto Universitario de Seguridad Industrial, Radiofísica y Medioambiental (ISIRYM), Universitat Politècnica de València (Spain)

    2017-07-01

    In the nuclear safety field, the thermal hydraulic phenomena that take place during an accident in a nuclear power plant is of special importance. One of the most studied accidents is the Station BlackOut (SBO). The aim of the present work is the analysis of the PKL integral test facility nodalization using the thermal-hydraulic code TRACE5 to reproduce a SBO accidental scenario. The PKL facility reproduces the main components of the primary and secondary systems of its reference nuclear power plant (Philippsburg II). The results obtained with different nodalization have been compared: 3D vessel vs 1D vessel, Steam Generator (SG) modelling using PIPE or TEE components and pressurizer modelling with PIPE or PRIZER components. Both vessel nodalization (1D vessel and 3D vessel) reproduce the physical phenomena of the experiment. However, there are significant discrepancies between them. The appropriate modelling of the SG is also relevant in the results. Regarding the other nodalization (PIPE or TEE components for SG and PIPE or PRIZER components for pressurizer), do not produce relevant differences in the results. (author)

  6. Economic simplified boiling water reactor (ESBWR) response to an extended station blackout/ loss of all AC power

    International Nuclear Information System (INIS)

    Barrett, A.J.; Marquino, W.

    2013-01-01

    U.S. federal regulations require light water cooled nuclear power plants to cope with Station Blackout for a predetermined amount of time based on design factors for the plant. U.S. regulations define Station Blackout (SBO) as a loss of the offsite electric power system concurrent with turbine trip and unavailability of the onsite emergency AC power system. According to U.S. regulations, typically the coping period for an SBO is 4 hours and can be as long as 16 hours for currently operating BWR plants. Being able to cope with an SBO and loss of all AC power is required by international regulators as well. The U.S. licensing basis for the ESBWR is a coping period of 72 hours for an SBO based on U.S. NRC requirements for passive safety plants. In the event of an extended SBO (viz., greater than 72 hours), the ESBWR response shows that the design is able to cope with the event for at least 7 days without AC electrical power or operator action. ESBWR is a Generation III+ reactor design with an array of passive safety systems. The ESBWR primary success path for mitigation of an SBO event is the Isolation Condenser System (ICS). The ICS is a passive, closed loop, safety system that initiates automatically on a loss of power. Upon Station Blackout or loss of all AC power, the ICS begins removing decay heat from the Reactor Pressure Vessel (RPV) by (i) condensing the steam into water in heat exchangers located in pools of water above the containment, and (ii) transferring the decay heat to the atmosphere. The condensed water is then returned by gravity to cool the reactor again. The ICS alone is capable of maintaining the ESBWR in a safe shutdown condition after an SBO for an extended period. The fuel remains covered throughout the SBO event. The ICS is able to remove decay heat from the RPV for at least 7 days and maintains the reactor in a safe shutdown condition. The water level in the RPV remains well above the top of active fuel for the duration of the SBO event

  7. Control and prediction for blackouts caused by frequency collapse in smart grids.

    Science.gov (United States)

    Wang, Chengwei; Grebogi, Celso; Baptista, Murilo S

    2016-09-01

    The electric power system is one of the cornerstones of modern society. One of its most serious malfunctions is the blackout, a catastrophic event that may disrupt a substantial portion of the system, playing havoc to human life and causing great economic losses. Thus, understanding the mechanisms leading to blackouts and creating a reliable and resilient power grid has been a major issue, attracting the attention of scientists, engineers, and stakeholders. In this paper, we study the blackout problem in power grids by considering a practical phase-oscillator model. This model allows one to simultaneously consider different types of power sources (e.g., traditional AC power plants and renewable power sources connected by DC/AC inverters) and different types of loads (e.g., consumers connected to distribution networks and consumers directly connected to power plants). We propose two new control strategies based on our model, one for traditional power grids and another one for smart grids. The control strategies show the efficient function of the fast-response energy storage systems in preventing and predicting blackouts in smart grids. This work provides innovative ideas which help us to build up a robuster and more economic smart power system.

  8. Light Water Reactor Sustainability Program: Analysis of Pressurized Water Reactor Station Blackout Caused by External Flooding Using the RISMC Toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Curtis [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mandelli, Diego [Idaho National Lab. (INL), Idaho Falls, ID (United States); Prescott, Steven [Idaho National Lab. (INL), Idaho Falls, ID (United States); Alfonsi, Andrea [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rabiti, Cristian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cogliati, Joshua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kinoshita, Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-08-01

    The existing fleet of nuclear power plants is in the process of extending its lifetime and increasing the power generated from these plants via power uprates. In order to evaluate the impact of these factors on the safety of the plant, the Risk Informed Safety Margin Characterization (RISMC) project aims to provide insight to decision makers through a series of simulations of the plant dynamics for different initial conditions (e.g., probabilistic analysis and uncertainty quantification). This report focuses, in particular, on the application of a RISMC detailed demonstration case study for an emergent issue using the RAVEN and RELAP-7 tools. This case study looks at the impact of a couple of challenges to a hypothetical pressurized water reactor, including: (1) a power uprate, (2) a potential loss of off-site power followed by the possible loss of all diesel generators (i.e., a station black-out event), (3) and earthquake induces station-blackout, and (4) a potential earthquake induced tsunami flood. The analysis is performed by using a set of codes: a thermal-hydraulic code (RELAP-7), a flooding simulation tool (NEUTRINO) and a stochastic analysis tool (RAVEN) – these are currently under development at the Idaho National Laboratory.

  9. Extended Station Blackout Analysis for VVER-1000 MWe Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Gaikwad, A. J.; Rao, R. S.; Lakshmanan, S. P.; Gupta, A., E-mail: avinashg@aerb.gov.in [Atomic Energy Regulatory Board, Mumbai (India)

    2014-10-15

    Post Fukushima, the plant behaviour for an extended station black-out (ESBO) scenario with only passive system availability for about 7 days has become imperative. Thermal hydraulic analysis of ESBO with the availability of passive heat removal system (PHRS), passive first stage and second stage hydro accumulators were carried out to demonstrate the design capabilities. Two different cases having primary leak rates of 2.2 tons/hr and 6.6 tons/hr were analyzed to study sustenance of natural circulation. For the study, out of 4 PHRS trains, one PHRS train was assumed to be in failure mode. The objective here is to predict the core cooling capability for a period of 7 days under ESBO conditions with the available water inventories from first and second stage hydroaccumulators only. Over simplified energy balance studies cannot ascertain sustenance of natural circulation in the primary system, steam generators (SGs) and PHRS. The analysis was carried out by using system thermal hydraulic safety code RELAP5/SCDAP/MOD 3.4. It is inferred that the inventory in the first stage accumulators and second stage accumulators compensate the leak and decay heat is removed effectively with the help of passive heat removal systems. It is also observed that even after 7 days of ESBO a large inventory is still available in the second stage accumulators and the primary system remains subcooled. (author)

  10. Light Water Reactor Sustainability Program: Analysis of Pressurized Water Reactor Station Blackout caused by external flooding using the RISMC toolkit

    International Nuclear Information System (INIS)

    2014-01-01

    The existing fleet of nuclear power plants is in the process of extending its lifetime and increasing the power generated from these plants via power uprates. In order to evaluate the impacts of these two factors on the safety of the plant, the Risk Informed Safety Margin Characterization project aims to provide insights to decision makers through a series of simulations of the plant dynamics for different initial conditions (e.g., probabilistic analysis and uncertainty quantification). This paper focuses on the impacts of power uprate on the safety margin of a boiling water reactor for a flooding induced station black-out event. Analysis is performed by using a combination of thermal-hydraulic codes and a stochastic analysis tool currently under development at the Idaho National Laboratory, i.e. RAVEN. We employed both classical statistical tools, i.e. Monte-Carlo, and more advanced machine learning based algorithms to perform uncertainty quantification in order to quantify changes in system performance and limitations as a consequence of power uprate. Results obtained give a detailed investigation of the issues associated with a plant power uprate including the effects of station black-out accident scenarios. We were able to quantify how the timing of specific events was impacted by a higher nominal reactor core power. Such safety insights can provide useful information to the decision makers to perform risk informed margins management.

  11. Analysis of core uncovery time in Kuosheng station blackout transient with MELCOR

    International Nuclear Information System (INIS)

    Wang, S.J.; Chien, C.S.

    1996-01-01

    The MELCOR code, developed by the Sandia National Laboratories, is capable of simulating severe accident phenomena of nuclear power plants. Core uncovery time is an important parameter in the probabilistic risk assessment. However, many MELCOR users do not generate the initial conditions in a station blackout (SBO) transient analysis. Thus, achieving reliable core uncovery time is difficult. The core uncovery time for the Kuosheng nuclear power plant during an SBO transient is analyzed. First, full-power steady-state conditions are generated with the application of a developed self-initialization algorithm. Then the response of the SBO transient up to core uncovery is simulated. The effects of key parameters including the initialization process and the reactor feed pump (RFP) coastdown time on the core uncovery time are analyzed. The initialization process is the most important parameter that affects the core uncovery time. Because SBO transient analysis, the correct initial conditions must be generated to achieve a reliable core uncovery time. The core uncovery time is also sensitive to the RFP coastdown time. A correct time constant is required

  12. Reactor coolant pump shaft seal behavior during blackout conditions

    International Nuclear Information System (INIS)

    Mings, W.J.

    1985-01-01

    The United States Nuclear Regulatory Commission has classified the problem of reactor coolant pump seal failures as an unresolved safety issue. This decision was made in large part due to experimental results obtained from a research program developed to study shaft seal performance during station blackout and reported in this paper. Testing and analysis indicated a potential for pump seal failure under postulated blackout conditions leading to a loss of primary coolant with a concomitant danger of core uncovery. The work to date has not answered all the concerns regarding shaft seal failure but it has helped scope the problem and focus future research needed to completely resolve this issue

  13. Benchmarking Simulation of Long Term Station Blackout Events

    International Nuclear Information System (INIS)

    Kim, Sung Kyum; Lee, John C.; Fynan, Douglas A.; Lee, John C.

    2013-01-01

    The importance of passive cooling systems has emerged since the SBO events. Turbine-driven auxiliary feedwater (TD-AFW) system is the only passive cooling system for steam generators (SGs) in current PWRs. During SBO events, all alternating current (AC) and direct current (DC) are interrupted and then the water levels of steam generators become high. In this case, turbine blades could be degraded and cannot cool down the SGs anymore. To prevent this kind of degradations, improved TD-AFW system should be installed for current PWRs, especially OPR 1000 plants. A long-term station blackout (LTSBO) scenario based on the improved TD-AFW system has been benchmarked as a reference input file. The following task is a safety analysis in order to find some important parameters causing the peak cladding temperature (PCT) to vary. This task has been initiated with the benchmarked input deck applying to the State-of-the-Art Reactor Consequence Analyses (SOARCA) Report. The point of the improved TD-AFW is to control the water level of the SG by using the auxiliary battery charged by a generator connected with the auxiliary turbine. However, this battery also could be disconnected from the generator. To analyze the uncertainties of the failure of the auxiliary battery, the simulation for the time-dependent failure of the TD-AFW has been performed. In addition to the cases simulated in the paper, some valves (e. g., pressurizer safety valve), available during SBO events in the paper, could be important parameters to assess uncertainties in PCTs estimated. The results for these parameters will be included in a future study in addition to the results for the leakage of the RCP seals. After the simulation of several transient cases, alternating conditional expectation (ACE) algorithm will be used to derive functional relationships between the PCT and several system parameters

  14. Alcohol-Induced Blackout

    Directory of Open Access Journals (Sweden)

    Dai Jin Kim

    2009-11-01

    Full Text Available For a long time, alcohol was thought to exert a general depressant effect on the central nervous system (CNS. However, currently the consensus is that specific regions of the brain are selectively vulnerable to the acute effects of alcohol. An alcohol-induced blackout is the classic example; the subject is temporarily unable to form new long-term memories while relatively maintaining other skills such as talking or even driving. A recent study showed that alcohol can cause retrograde memory impairment, that is, blackouts due to retrieval impairments as well as those due to deficits in encoding. Alcoholic blackouts may be complete (en bloc or partial (fragmentary depending on severity of memory impairment. In fragmentary blackouts, cueing often aids recall. Memory impairment during acute intoxication involves dysfunction of episodic memory, a type of memory encoded with spatial and social context. Recent studies have shown that there are multiple memory systems supported by discrete brain regions, and the acute effects of alcohol on learning and memory may result from alteration of the hippocampus and related structures on a cellular level. A rapid increase in blood alcohol concentration (BAC is most consistently associated with the likelihood of a blackout. However, not all subjects experience blackouts, implying that genetic factors play a role in determining CNS vulnerability to the effects of alcohol. This factor may predispose an individual to alcoholism, as altered memory function during intoxication may affect an individual‟s alcohol expectancy; one may perceive positive aspects of intoxication while unintentionally ignoring the negative aspects. Extensive research on memory and learning as well as findings related to the acute effects of alcohol on the brain may elucidate the mechanisms and impact associated with the alcohol- induced blackout.

  15. Test study on safety features of station blackout accident for nuclear main pump

    International Nuclear Information System (INIS)

    Liu Xiajie; Wang Dezhong; Zhang Jige; Liu Junsheng; Yang Zhe

    2009-01-01

    The theoretical and experimental studies of reactor coolant pump accidents encountered nation-wide and world-wide were described. To investigate the transient hydrodynamic performance of reactor coolant pump (RCP) during the period of rotational inertia in the station blackout accident, some theoretical and experimental studies were carried out, and the analysis of the test results was presented. The experiment parameters, conditions and test methods were introduced. The flow-rate, rotate speed and vibrations were analyzed emphatically. The quadruplicate polynomial curve equation was used to simulate the flow-rate,rotate speed along with time. The test results indicate that the flow-rate and rotator speed decrease rapidly at the very beginning of cut power and the test results accord with the regulation of safety standard. The vibrant displacement of bearing seat is intensified at the moment of lose power, but after a certain period rotor shaft libration changes. The test and analysis results help to understand the hydrodynamic performance of nuclear primary pump under lost of power accident, and provide the basic reference for safety evaluation. (authors)

  16. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Kyemin; Jang, Seung-cheol [KAERI, Daejeon (Korea, Republic of); Heo, Gyunyoung [Kyung Hee University, Yongin (Korea, Republic of)

    2015-05-15

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future.

  17. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    International Nuclear Information System (INIS)

    Oh, Kyemin; Jang, Seung-cheol; Heo, Gyunyoung

    2015-01-01

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future

  18. The NUREG-1150 probabilistic risk assessment for the Grand Gulf nuclear station

    International Nuclear Information System (INIS)

    Brown, T.D.; Breeding, R.J.; Jow, H.N.; Higgins, S.J.; Shiver, A.W.; Helton, J.C.

    1992-01-01

    This paper summarizes the findings of the probabilistic risk assessment (PRA) for Unit 1 of the Grand Gulf Nuclear Station performed in support of NUREG-1150. The emphasis is on the 'back-end' analyses, that is, the acident progression, source term, consequence analsyes, and risk results obtained when the results of these analyses are combined with the accident frequency analysis. The offsite risk from internal initiating events was found to be quite low, both with respect to the safety goals and to the other plants analyzed in NUREG-1150. The offsite risk is dominated by short-term station blackout plant damage states. The long-term blackout group and the anticiptated transients without scram (ATWS) group contribute considerably less to risk. Transients in which the power conversion system is unavailable are very minor contributors to risk. The low values for risk can be attributed to low core damage frequency, good emergency response, and plant features that reduce the potential source term. (orig.)

  19. The integrity of NSSS and containment during extended station blackout for Kuosheng BWR plant

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Keng-Hsien; Yuann, Yng-Ruey; Lin, Ansheng [Atomic Energy Council, Taoyuan City, Taiwan (China). Inst. of Nuclear Energy Research

    2017-11-15

    The Fukushima Daiichi accident occurring on March 11, 2011, reveals that Station Blackout (SBO) may last longer than 8 h. However, the original design may not have sufficient capacity to cope with a SBO for more than 8 h. In view of this, Taiwan Power Company has initiated several enhancements to mitigate the severity of the extended SBO. Based on the improved plant configuration, a SBO coping analysis is performed in this study to assess whether the Kuosheng BWR plant has sufficient capability to cope with SBO for 24 h with respect to maintaining the integrity of the reactor core and containment. The analyses in the Nuclear Steam Supply System (NSSS) and the containment are based on the RETRAN-3D and GOTHIC models, respectively. The flow conditions calculated by RETRAN-3D during the event are retrieved and input to the GOTHIC containment model to determine the containment pressure and temperature response. These boundary conditions include SRV flow rate, SRV flow enthalpy, and total reactor coolant system leakage flow rate.

  20. The integrity of NSSS and containment during extended station blackout for Kuosheng BWR plant

    International Nuclear Information System (INIS)

    Hsu, Keng-Hsien; Yuann, Yng-Ruey; Lin, Ansheng

    2017-01-01

    The Fukushima Daiichi accident occurring on March 11, 2011, reveals that Station Blackout (SBO) may last longer than 8 h. However, the original design may not have sufficient capacity to cope with a SBO for more than 8 h. In view of this, Taiwan Power Company has initiated several enhancements to mitigate the severity of the extended SBO. Based on the improved plant configuration, a SBO coping analysis is performed in this study to assess whether the Kuosheng BWR plant has sufficient capability to cope with SBO for 24 h with respect to maintaining the integrity of the reactor core and containment. The analyses in the Nuclear Steam Supply System (NSSS) and the containment are based on the RETRAN-3D and GOTHIC models, respectively. The flow conditions calculated by RETRAN-3D during the event are retrieved and input to the GOTHIC containment model to determine the containment pressure and temperature response. These boundary conditions include SRV flow rate, SRV flow enthalpy, and total reactor coolant system leakage flow rate.

  1. Electrical Power System Design and Station Blackout (SBO) Management in Indian Fast Breeder Reactors

    International Nuclear Information System (INIS)

    Vijaya, N. M.; Theivarajan, N.; Madhusoodanan, K.

    2015-01-01

    In the nuclear new builds and projects in design stage SBO management measures have significant role. Depending on the onsite and offsite power supply configurations, deterministic SBO duration is established. Design of systems with adequately sized battery capacities for SBO duration, special SBO Diesel Generator Sets, structured load shedding strategy to conserve battery availability to cope with SBO and to monitor the plant safety beyond SBO duration are considered as part of electrical system design now. In the design of PFBR, SBO is given due importance right from conceptual design stage. Both deterministic SBO duration and probabilistic SBO duration versus frequency were established by detailed analysis. Dedicated DC power supply systems and additional SBO DG back-up systems are in place to cope with normal and extended SBO. After the Fukushima event, there is greater requirement to demonstrate plant safety during SBO for a long duration extended over several days. In light of this accident, thermal hydraulic synthesis of PFBR has been carried out to ascertain the capability of the plant to manage a prolonged station blackout event. This has brought out the robustness of the design. Safety design features of PFBR ensure comfortable management of extended SBO. In the design of future FBR projects, current trends in the new nuclear builds and recommendations of international bodies considering Fukushima are duly considered. SBO measures by means of alternate AC power sources, redundant emergency power supply sources with less dependence on other auxiliary systems and dedicated DC power systems are considered to cope with normal and extended SBO beyond design basis. Right from the conceptual design, the system robustness to manage normal and extended SBO will be taken care with the related thermal hydraulic and associated analysis. The paper highlights these SBO management strategies in PFBR and future FBRs. (author)

  2. Preliminary Evaluations of CSPACE for a Station Blackout Transient in APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Lee, T. B.; Lee, D. K.; Lee, H. S.; Lee, G. W.; Choi, T. S. [KEPCO, Daejeon (Korea, Republic of); Park, R. J.; Kim, D. H. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    This paper discusses the preliminary results of the simulated station blackout (SBO) transients using the CSPACE code and presents the information pertinent to the related safety issues. CSPACE is a merged program of a master processer of Safety and Performance Analysis Code (SPACE) for nuclear power plants and a child processer of Core Meltdown Progression Accident Simulation Software (COMPASS) generated as a dynamic-link library (DLL) codes. It has been developed to predict the best-estimate transient in the pressurized water reactor (PWR) for severe accidents. SPACE and COMPASS codes take charge of the thermal-hydraulic response of PWRs and the analysis of the severe accident progression in a vessel, respectively. The initial phase is estimated starting from time zero when the loss of off-site and on-site powers occurs simultaneously. Shortly after the RCS pressure initially falls and rises slightly due to the effects of the reactor and turbine trips, the RCS pressure declines in response to the cooling provided by heat removed to the SGs. During the period of the primary heat-up and boil-off, the RCS pressure increase is limited by two cycles of the POSRV. The RCS fluid mass is lost through the pressurizer POSRV and then the core uncovers and superheated steam flows out from the RV into the coolant loops starting at 5513.0 seconds.

  3. Mitigating reentry radio blackout by using a traveling magnetic field

    Directory of Open Access Journals (Sweden)

    Hui Zhou

    2017-10-01

    Full Text Available A hypersonic flight or a reentry vehicle is surrounded by a plasma layer that prevents electromagnetic wave transmission, which results in radio blackout. The magnetic-window method is considered a promising means to mitigate reentry communication blackout. However, the real application of this method is limited because of the need for strong magnetic fields. To reduce the required magnetic field strength, a novel method that applies a traveling magnetic field (TMF is proposed in this study. A mathematical model based on magneto-hydrodynamic theory is adopted to analyze the effect of TMF on plasma. The mitigating effects of the TMF on the blackout of typical frequency bands, including L-, S-, and C-bands, are demonstrated. Results indicate that a significant reduction of plasma density occurs in the magnetic-window region by applying a TMF, and the reduction ratio is positively correlated with the velocity of the TMF. The required traveling velocities for eliminating the blackout of the Global Positioning System (GPS and the typical telemetry system are also discussed. Compared with the constant magnetic-window method, the TMF method needs lower magnetic field strength and is easier to realize in the engineering field.

  4. Mitigating reentry radio blackout by using a traveling magnetic field

    Science.gov (United States)

    Zhou, Hui; Li, Xiaoping; Xie, Kai; Liu, Yanming; Yu, Yuanyuan

    2017-10-01

    A hypersonic flight or a reentry vehicle is surrounded by a plasma layer that prevents electromagnetic wave transmission, which results in radio blackout. The magnetic-window method is considered a promising means to mitigate reentry communication blackout. However, the real application of this method is limited because of the need for strong magnetic fields. To reduce the required magnetic field strength, a novel method that applies a traveling magnetic field (TMF) is proposed in this study. A mathematical model based on magneto-hydrodynamic theory is adopted to analyze the effect of TMF on plasma. The mitigating effects of the TMF on the blackout of typical frequency bands, including L-, S-, and C-bands, are demonstrated. Results indicate that a significant reduction of plasma density occurs in the magnetic-window region by applying a TMF, and the reduction ratio is positively correlated with the velocity of the TMF. The required traveling velocities for eliminating the blackout of the Global Positioning System (GPS) and the typical telemetry system are also discussed. Compared with the constant magnetic-window method, the TMF method needs lower magnetic field strength and is easier to realize in the engineering field.

  5. Mitigating fuel handling situations during station blackout in TAPP-3 and

    International Nuclear Information System (INIS)

    Chugh, V.K.; Roy, Shibaji; Gupta, H.; Inder Jit

    2002-01-01

    Full text: On power refueling is one of the important features of PHWRs. fuelling machine (FM) Head becomes part of the reactor pressure boundary during refueling operations. Hot irradiated (spent) fuel bundles are received in the FM Head from the Reactor and transferred to spent fuel storage bay (SFSB). These bundles pass through various fuel handling (FH) Equipment under submerged condition except during the dry transfer operation. Situations of station blackout (SBO) i.e. postulated simultaneous failure of Class III and Class IV electric power, could persist for a long period, during on-reactor or off-reactor FH operations, with the spent fuel bundles being any where in the system between the reactor and SFSB. The cooling provisions for the spent fuel bundles vary depending upon the stage of operation. During SBO, it becomes difficult to maintain cooling to these fuel bundles due to the limited availability of Class II power and instrument air. However, cooling is essential, to ensure the safety of the bundles. As discussed in the paper, safety of these fuel bundles in the system and/or for those lying in the liner tube region of the reactor end fitting is ensured, during SBO, by resorting to passive means like stay-put, gravity- fill, D 2 O-steaming etc. for cooling the bundles. Various scenarios have been identified for cooling provisions of the bundles in the system. The paper also describes consequences like loss of D 2 O inventory, rise in ambient temperature and pressure and tritium build-up in Reactor Building, emanating from these cooling schemes

  6. Study of a Station Blackout Event in the PWR Plant

    International Nuclear Information System (INIS)

    Ching-Hui Wu; Tsu-Jen Lin; Tsu-Mu Kao

    2002-01-01

    On March 18, 2001, a PWR nuclear power plant located in the Southern Taiwan occurred a Station Blackout (SBO) event. Monsoon seawater mist caused the instability of offsite power grids. High salt-contained mist caused offsite power supply to the nuclear power plant very unstable, and forced the plant to be shutdown. Around 24 hours later, when both units in the plant were shutdown, several inadequate high cycles of bus transfer between 345 kV and 161 kV startup transformers degraded the emergency 4.16 kV switchgears. Then, in the Train-A switchgear room of Unit 1 occurred a fire explosion, when the degraded switchgear was hot shorted at the in-coming 345 kV breaker. Inadequate configuration arrangement of the offsite power supply to the emergency 4.16 kV switchgears led to loss of offsite power (LOOP) events to both units in the plant. Both emergency diesel generators (EDG) of Unit 1 could not be in service in time, but those of Unit 2 were running well. The SBO event of Unit 1 lasted for about two hours till the fifth EDG (DG-5) was lined-up to the Train-B switchgear. This study investigated the scenario of the SBO event and evaluated a risk profile for the SBO period. Guidelines in the SBO event, suggested by probabilistic risk assessment (PRA) procedures were also reviewed. Many related topics such as the re-configuration of offsite power supply, the addition of isolation breakers of the emergency 4.16 kV switchgears, the betterment of DG-5 lineup design, and enhancement of the reliability of offsite power supply to the PWR plant, etc., will be in further studies. (authors)

  7. Investigation of a Station Blackout Scenario with the ATLAS Test

    International Nuclear Information System (INIS)

    Kim, Yeon Sik; Yu, Xin Guo; Kang, Kyoung Ho; Park, Hyun Sik; Cho, Seok; Min, Kyeong Ho; Choi, Nam Hyeon; Kim, Bok Deuk; Park, Jong Gook; Choi, Ki Yong

    2012-01-01

    KAERI (Korea Atomic Energy Research Institute) has been operating an integral effect test facility, ATLAS (Advanced Thermal-Hydraulic Test Loop for Accident Simulation), for accident simulations pertaining to the OPR1000 (Optimized Power Reactor, 1000MWe) and the APR1400 (Advanced Power Reactor, 1400MWe) which are in operation and under construction in Korea, respectively. After the Fukushima accidents due to the combination of an earthquake followed by a tsunami in east Japan on March 11, 2011, the concept of boundary between the design basis and beyond-design basis accidents became obscure. One scenario is the station blackout (SBO), which is defined as 'the loss of all alternating current (AC) power in a nuclear power plant' by the USNRC 10CFR50 Section 50.63, which has adopted a new safety regulation for the SBO in June of 1988. In any case the SBO that occurred in Fukushima seemed to go beyond the definition of the current SBO scenario. In the mean time, numerous researches has been conducted on the safety concern of the SBO for existing and advanced nuclear power plants worldwide. From the internal review of an SBO scenario, it was concluded that the understanding of the thermo-hydraulic phenomena occurred within the reactor coolant system is a prerequisite although seemed to be quite a simple sequence of events. This was the motivation of an SBO test using the ATLAS facility. For the understanding of the physical phenomena within the primary system, an SBO was assumed with simple intial and boundary conditions, e.g. start of an SBO at time zero, no diesel and AC powers, no auxiliary feedwater pumps (motor-driven and turbine driven) etc. In this paper, overview of the SBO test results was described including a result of analytical calculations simulating the SBO test using the MARS code

  8. Simulation with the MELCOR code of two severe accident sequences, Station Blackout and Small Break LOCA, for the Atucha I nuclear power plant

    International Nuclear Information System (INIS)

    Valle Cepero, Reinaldo

    2004-01-01

    The results of the PSA-I applied to the Atucha I nuclear power plant (CNA I) determine the accidental sequences with the most influence related to the probability of the core reactor damage. Among those sequences are include, the Station Blackout and lost of primary coolant, combine with the failure of the emergency injection systems by pipe breaks of diameters between DN100 - DN25 or equivalent areas, Small LOCA. This paper has the objective to model and analyze the behavior of the primary circuit and the pressure vessel during the evolution of those two accidental sequences. It presented a detailed analysis of the main phenomena that occur from the initial moment of the accident to the failure moment of the pressure vessel and the melt material fall to the reactor cavity. Two sequences were taken into account, considering the main phenomena (core uncover, heating, fuel element oxidation, hydrogen generation, degradation and relocation of the melt material, failure of the support structures, etc.) and the time of occurrence, of those events will be different, if it is considered that both sequences will be developed in different scenarios. One case is an accident with the primary circuit to a high pressure (Station Blackout scenario) and the other with a early primary circuit depressurization due to the lost of primary coolant. For this work the MELCOR 1.8.5 code was used and it allows within a unified framework to modeling an extensive spectrum of phenomenology associated with the severe accidents. (author)

  9. Evaluating the effect of a campus-wide social norms marketing intervention on alcohol-use perceptions, consumption, and blackouts.

    Science.gov (United States)

    Su, Jinni; Hancock, Linda; Wattenmaker McGann, Amanda; Alshagra, Mariam; Ericson, Rhianna; Niazi, Zackaria; Dick, Danielle M; Adkins, Amy

    2018-04-01

    To evaluate the effect of a campus-wide social norms marketing intervention on alcohol-use perceptions, consumption, and blackouts at a large, urban, public university. 4,172 college students (1,208 freshmen, 1,159 sophomores, 953 juniors, and 852 seniors) who completed surveys in Spring 2015 for the Spit for Science Study, a longitudinal study of students' substance use and emotional health. Participants were e-mailed an online survey that queried campaign readership, perception of peer alcohol use, alcohol consumption, frequency of consumption, and frequency of blackouts. Associations between variables were evaluated using path analysis. We found that campaign readership was associated with more accurate perceptions of peer alcohol use, which, in turn, was associated with self-reported lower number of drinks per sitting and experiencing fewer blackouts. This evaluation supports the use of social norms marketing as a population-level intervention to correct alcohol-use misperceptions and reduce blackouts.

  10. Station Blackout Analysis for a 3-Loop Westinghouse PWR Reactor Using Trace

    International Nuclear Information System (INIS)

    El-Sahlamy, N.M.

    2017-01-01

    One of the main concerns in the area of severe accidents in nuclear reactors is that of station blackout (SBO). The loss of offsite electrical power concurrent with the unavailability of the onsite emergency alternating current (AC) power system can result in loss of decay heat removal capability, leading to a potential core damage which may lead to undesirable consequences to the public and the environment. To cope with an SBO, nuclear reactors are provided with protection systems that automatically shut down the reactor, and with safety systems to remove the core residual heat. This paper provides a best estimate assessment of the SBO scenario in a 3-loop Westinghouse PWR reactor. The evaluation is performed using TRACE, a best estimate computer code for thermal-hydraulic calculations. Two sets of scenarios for SBO analyses are discussed in the current work. The first scenario is the short term SBO where it is assumed that in addition to the loss of AC power, there is no DC power; i.e., no batteries are available. In the second scenario, a long term SBO is considered. For this scenario, DC batteries are available for four hours. The aim of the current SBO analyses for the 3-loop pressurized water reactor presented in this paper is to focus on the effect of the availability of a DC power source to delay the time to core uncovers and heatup

  11. A portable backup power supply to assure extended decay heat removal during natural phenomena-induced station blackout

    International Nuclear Information System (INIS)

    Proctor, L.D.; Merryman, L.D.; Sallee, W.E.

    1989-01-01

    The High Flux Isotope Reactor (HFIR) is a light water cooled and moderated flux-trap type research reactor located at Oak Ridge National Laboratory (ORNL). Coolant circulation following reactor shutdown is provided by the primary coolant pumps. DC-powered pony motors drive these pumps at a reduced flow rate following shutdown of the normal ac-powered motors. Forced circulation decay heat removal is required for several hours to preclude core damage following shutdown. Recent analyses identified a potential vulnerability due to a natural phenomena-induced station blackout. Neither the offsire power supply nor the onsite emergency diesel generators are designed to withstand the effects of seismic events or tornadoes. It could not be assured that the capacity of the dedicated batteries provided as a backup power supply for the primary coolant pump pony motors is adequate to provide forced circulation cooling for the required time following such events. A portable backup power supply added to the plant to address this potential vulnerability is described

  12. 47 CFR 76.111 - Cable sports blackout.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable sports blackout. 76.111 Section 76.111... CABLE TELEVISION SERVICE Network Non-duplication Protection, Syndicated Exclusivity and Sports Blackout § 76.111 Cable sports blackout. (a) No community unit located in whole or in part within the specified...

  13. Comparison of oxide- and metal-core behavior during CRBRP [Clinch River Breeder Reactor Plant] station blackout

    International Nuclear Information System (INIS)

    Polkinghorne, S.T.; Atkinson, S.A.

    1986-01-01

    A resurrected concept that could significantly improve the inherently safe response of Liquid-Metal cooled Reactors (LMRs) during severe undercooling transients is the use of metallic fuel. Analytical studies have been reported on for the transient behavior of metal-fuel cores in innovative, inherently safe LMR designs. This paper reports on an analysis done, instead, for the Clinch River Breeder Reactor Plant (CRBRP) design with the only innovative change being the incorporation of a metal-fuel core. The SSC-L code was used to simulate a protected station blackout accident in the CRBRP with a 943 MWt Integral Fast Reactor (IFR) metal-fuel core. The results, compared with those for the oxide-fueled CRBRP, show that the margin to boiling is greater for the IFR core. However, the cooldown transient is more severe due to the faster thermal response time of metallic fuel. Some additional calculations to assess possible LMR design improvements (reduced primary system pressure losses, extended flow coastdown) are also discussed. 8 refs., 13 figs., 2 tabs

  14. 47 CFR 76.127 - Satellite sports blackout.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Satellite sports blackout. 76.127 Section 76... Sports Blackout § 76.127 Satellite sports blackout. (a) Upon the request of the holder of the broadcast rights to a sports event, or its agent, no satellite carrier shall retransmit to subscribers within the...

  15. Station blackout with failure of wired shutdown system for AHWR

    International Nuclear Information System (INIS)

    Srivastava, A.; Contractor, A.D.; Chatterjee, B.; Kumar, Rajesh

    2015-01-01

    Advanced Heavy Water Reactor (AHWR) is a vertical pressure tube type boiling light water cooled and heavy water moderated reactor. This reactor has several advance safety features. One of the important passive design features of this reactor is that the heat removal is achieved through natural circulation of primary coolant at all power level without primary coolant pumps. Station blackout (SBO) scenario has become very important in aftermath of Fukushima event. The existing reactor has to demonstrate that design features are sufficient to mitigate the scenario whereas the new reactor design are adding specific features to tackle such scenario for prolonged period. The present study demonstrates the design features of AHWR to mitigate the SBO scenario along with failure of wired shutdown system. SBO event leads to feed water pump trip and loss of condenser vacuum which in turn results into loss of feed water and turbine trip on low condenser vacuum signal. Stoppage of steam flow to the turbine and bypass to the condenser lead to bottling up of the system, causing MHT pressure to rise. In the absence of reactor scram, the pressure continues to rise. Isolation Condenser (IC) valve starts opening at a pressure of 7.65 MPa. The pressure continues to rise as IC system is designed for decay heat removal and reactor power is brought down to decay power level through Passive Poison Injection System (PPIS) when the pressure reaches 8.4 MPa. The analysis shows that the event do not lead to undesirable clad surface temperature rise due to reactor trip by PPIS and decay heat removal for prolonged time by IC system. Thermal hydraulic response of different parameters like pressure, temperatures, and flows in MHT system is analyzed for this scenario. Pressure during transient is found to be well below the system pressure criteria of 110% of design pressure. This analysis highlights the design robustness of AHWR. (author)

  16. Comparison of MELCOR modeling techniques and effects of vessel water injection on a low-pressure, short-term, station blackout at the Grand Gulf Nuclear Station

    International Nuclear Information System (INIS)

    Carbajo, J.J.

    1995-06-01

    A fully qualified, best-estimate MELCOR deck has been prepared for the Grand Gulf Nuclear Station and has been run using MELCOR 1.8.3 (1.8 PN) for a low-pressure, short-term, station blackout severe accident. The same severe accident sequence has been run with the same MELCOR version for the same plant using the deck prepared during the NUREG-1150 study. A third run was also completed with the best-estimate deck but without the Lower Plenum Debris Bed (BH) Package to model the lower plenum. The results from the three runs have been compared, and substantial differences have been found. The timing of important events is shorter, and the calculated source terms are in most cases larger for the NUREG-1150 deck results. However, some of the source terms calculated by the NUREG-1150 deck are not conservative when compared to the best-estimate deck results. These results identified some deficiencies in the NUREG-1150 model of the Grand Gulf Nuclear Station. Injection recovery sequences have also been simulated by injecting water into the vessel after core relocation started. This marks the first use of the new BH Package of MELCOR to investigate the effects of water addition to a lower plenum debris bed. The calculated results indicate that vessel failure can be prevented by injecting water at a sufficiently early stage. No pressure spikes in the vessel were predicted during the water injection. The MELCOR code has proven to be a useful tool for severe accident management strategies

  17. The safety assessment of OPR-1000 nuclear power plant for station blackout accident applying the combined deterministic and probabilistic procedure

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dong Gu, E-mail: littlewing@kins.re.kr [Korea Institute of Nuclear Safety, 62 Gwahak-ro, Yuseong-gu, Daejeon 305-338 (Korea, Republic of); Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Chang, Soon Heung [Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)

    2014-08-15

    Highlights: • The combined deterministic and probabilistic procedure (CDPP) was proposed for safety assessment of the BDBAs. • The safety assessment of OPR-1000 nuclear power plant for SBO accident is performed by applying the CDPP. • By estimating the offsite power restoration time appropriately, the SBO risk is reevaluated. • It is concluded that the CDPP is applicable to safety assessment of BDBAs without significant erosion of the safety margin. - Abstract: Station blackout (SBO) is a typical beyond design basis accident (BDBA) and significant contributor to overall plant risk. The risk analysis of SBO could be important basis of rulemaking, accident mitigation strategy, etc. Recently, studies on the integrated approach of deterministic and probabilistic method for nuclear safety in nuclear power plants have been done, and among them, the combined deterministic and probabilistic procedure (CDPP) was proposed for safety assessment of the BDBAs. In the CDPP, the conditional exceedance probability obtained by the best estimate plus uncertainty method acts as go-between deterministic and probabilistic safety assessments, resulting in more reliable values of core damage frequency and conditional core damage probability. In this study, the safety assessment of OPR-1000 nuclear power plant for SBO accident was performed by applying the CDPP. It was confirmed that the SBO risk should be reevaluated by eliminating excessive conservatism in existing probabilistic safety assessment to meet the targeted core damage frequency and conditional core damage probability. By estimating the offsite power restoration time appropriately, the SBO risk was reevaluated, and it was finally confirmed that current OPR-1000 system lies in the acceptable risk against the SBO. In addition, it is concluded that the CDPP is applicable to safety assessment of BDBAs in nuclear power plants without significant erosion of the safety margin.

  18. Assessment of the potential for high-pressure melt ejection resulting from a Surry station blackout transient

    International Nuclear Information System (INIS)

    Knudson, D.L.; Dobbe, C.A.

    1993-11-01

    Containment integrity could be challenged by direct heating associated with a high pressure melt ejection (HPME) of core materials following reactor vessel breach during certain severe accidents. Intentional reactor coolant system (RCS) depressurization, where operators latch pressurizer relief valves open, has been proposed as an accident management strategy to reduce risks by mitigating the severity of HPME. However, decay heat levels, valve capacities, and other plant-specific characteristics determine whether the required operator action will be effective. Without operator action, natural circulation flows could heat ex-vessel RCS pressure boundaries (surge line and hot leg piping, steam generator tubes, etc.) to the point of failure before vessel breach, providing an alternate mechanism for RCS depressurization and HPME mitigation. This report contains an assessment of the potential for HPME during a Surry station blackout transient without operator action and without recovery. The assessment included a detailed transient analysis using the SCDAP/RELAP5/MOD3 computer code to calculate the plant response with and without hot leg countercurrent natural circulation, with and without reactor coolant pump seal leakage, and with variations on selected core damage progression parameters. RCS depressurization-related probabilities were also evaluated, primarily based on the code results

  19. Long-Term Station Blackout Accident Analyses of a PWR with RELAP5/MOD3.3

    Directory of Open Access Journals (Sweden)

    Andrej Prošek

    2013-01-01

    Full Text Available Stress tests performed in Europe after accident at Fukushima Daiichi also required evaluation of the consequences of loss of safety functions due to station blackout (SBO. Long-term SBO in a pressurized water reactor (PWR leads to severe accident sequences, assuming that existing plant means (systems, equipment, and procedures are used for accident mitigation. Therefore the main objective was to study the accident management strategies for SBO scenarios (with different reactor coolant pumps (RCPs leaks assumed to delay the time before core uncovers and significantly heats up. The most important strategies assumed were primary side depressurization and additional makeup water to reactor coolant system (RCS. For simulations of long term SBO scenarios, including early stages of severe accident sequences, the best estimate RELAP5/MOD3.3 and the verified input model of Krško two-loop PWR were used. The results suggest that for the expected magnitude of RCPs seal leak, the core uncovery during the first seven days could be prevented by using the turbine-driven auxiliary feedwater pump and manually depressurizing the RCS through the secondary side. For larger RCPs seal leaks, in general this is not the case. Nevertheless, the core uncovery can be significantly delayed by increasing RCS depressurization.

  20. Fractal Characteristics Analysis of Blackouts in Interconnected Power Grid

    DEFF Research Database (Denmark)

    Wang, Feng; Li, Lijuan; Li, Canbing

    2018-01-01

    The power failure models are a key to understand the mechanism of large scale blackouts. In this letter, the similarity of blackouts in interconnected power grids (IPGs) and their sub-grids is discovered by the fractal characteristics analysis to simplify the failure models of the IPG. The distri......The power failure models are a key to understand the mechanism of large scale blackouts. In this letter, the similarity of blackouts in interconnected power grids (IPGs) and their sub-grids is discovered by the fractal characteristics analysis to simplify the failure models of the IPG....... The distribution characteristics of blackouts in various sub-grids are demonstrated based on the Kolmogorov-Smirnov (KS) test. The fractal dimensions (FDs) of the IPG and its sub-grids are then obtained by using the KS test and the maximum likelihood estimation (MLE). The blackouts data in China were used...

  1. Study on self organized criticality of China power grid blackouts

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Xingyong; Zhang, Xiubin; He, Bin [Department of Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Minhang District, Shanghai 200240 (China)

    2009-03-15

    Based on the complex system theory and the concept of self organized criticality (SOC) theory, the mechanism of China power grid blackout is studied by analyzing the blackout data in the China power system from 1981 to 2002. The probability distribution functions of various measures of blackout size have a power tail. The analysis of scaled window variance and rescaled range statistics of the time series show moderate long time correlations. The blackout data seem consistent with SOC; the results obtained show that SOC dynamics may play an important role in the dynamics of power systems blackouts. It would be possible to propose novel approaches for understanding and controlling power systems blackouts. (author)

  2. Study on self organized criticality of China power grid blackouts

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Xingyong [Department of Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Minhang District, Shanghai 200240 (China)], E-mail: zhaoxingyong@sjtu.edu.cn; Zhang Xiubin; He Bin [Department of Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Minhang District, Shanghai 200240 (China)

    2009-03-15

    Based on the complex system theory and the concept of self organized criticality (SOC) theory, the mechanism of China power grid blackout is studied by analyzing the blackout data in the China power system from 1981 to 2002. The probability distribution functions of various measures of blackout size have a power tail. The analysis of scaled window variance and rescaled range statistics of the time series show moderate long time correlations. The blackout data seem consistent with SOC; the results obtained show that SOC dynamics may play an important role in the dynamics of power systems blackouts. It would be possible to propose novel approaches for understanding and controlling power systems blackouts.

  3. Assessment of the potential for HPME during a station blackout in the Surry and Zion PWRS

    International Nuclear Information System (INIS)

    Knudson, D.L.; Bayless, P.D.; Dobbe, C.A.; Odar, F.

    1994-01-01

    The integrity of a PWR (pressurized water reactor) containment structure could be challenged by direct heating associated with a HPME (high pressure melt ejection) of core materials following reactor vessel lower head breach during certain severe accidents. Structural failure resulting from direct containment heating is a contributor to the risk of operating a PWR. Intentional RCS (reactor coolant system) depressurization, where operators latch pressurizer relief valves open, has been proposed as an accident management strategy to reduce those risks by mitigating the severity of the HPME. However, decay heat levels, valve capacities, and other plant-specific characteristics determine whether the required operator action will be effective. Without operator action, natural circulation flows could heat ex-vessel RCS pressure boundaries (surge line and hot leg piping, steam generator tubes, etc.) to the point of failure before failure of the lower head providing an unintentional mechanism for depressurization and HPME mitigation. This paper summarizes an assessment of RCS depressurization with respect to the potential for HPME during a station blackout in the Surry and Zion PWRs. The assessment included a detailed transient analysis using the SCDAP/RELAP5/MOD3 computer code and an evaluation of RCS depressurization-related probabilities primarily based on the code results

  4. Broadcasting Stations of the World; Part III. Frequency Modulation Broadcasting Stations.

    Science.gov (United States)

    Foreign Broadcast Information Service, Washington, DC.

    This third part of "Broadcasting Stations of the World", which lists all reported radio broadcasting and television stations, with the exception of those in the United States which broadcast on domestic channels, covers frequency modulation broadcasting stations. It contains two sections: one indexed alphabetically by country and city, and the…

  5. Modeling and analysis of selected organization for economic cooperation and development PKL-3 station blackout experiments using TRACE

    Directory of Open Access Journals (Sweden)

    Roman Mukin

    2018-04-01

    Full Text Available A series of tests dedicated to station blackout (SBO accident scenarios have been recently performed at the Primärkreislauf-Versuchsanlage (primary coolant loop test facility; PKL facility in the framework of the OECD/NEA PKL-3 project. These investigations address current safety issues related to beyond design basis accident transients with significant core heat up. This work presents a detailed analysis using the best estimate thermal–hydraulic code TRACE (v5.0 Patch4 of different SBO scenarios conducted at the PKL facility; failures of high- and low-pressure safety injection systems together with steam generator (SG feedwater supply are considered, thus calling for adequate accident management actions and timely implementation of alternative emergency cooling procedures to prevent core meltdown. The presented analysis evaluates the capability of the applied TRACE model of the PKL facility to correctly capture the sequences of events in the different SBO scenarios, namely the SBO tests H2.1, H2.2 run 1 and H2.2 run 2, including symmetric or asymmetric secondary side depressurization, primary side depressurization, accumulator (ACC injection in the cold legs and secondary side feeding with mobile pump and/or primary side emergency core coolant injection from the fuel pool cooling pump. This study is focused specifically on the prediction of the core exit temperature, which drives the execution of the most relevant accident management actions. This work presents, in particular, the key improvements made to the TRACE model that helped to improve the code predictions, including the modeling of dynamical heat losses, the nodalization of SGs' heat exchanger tubes and the ACCs. Another relevant aspect of this work is to evaluate how well the model simulations of the three different scenarios qualitatively and quantitatively capture the trends and results exhibited by the actual experiments. For instance, how the number of SGs considered for

  6. Analyses of natural circulation during a Surry station blackout using SCDAP/RELAP5

    International Nuclear Information System (INIS)

    Bayless, P.D.

    1988-10-01

    The effects of reactor coolant system natural circulation on the response of the Surry nuclear power plant during a station blackout transient were investigated. A TMLB' sequence (loss of all ac power, immediate loss of auxillary feedwater) was simulated from transient initiation until after fuel rod relocation had begun. Integral analyses of the system thermal-hydraulics and the core damage behavior were performed using the SCDAP/RELAP5 computer code and several different models of the plant. Three scoping calculations were performed in which the complexity of the plant model was progressively increased to determine the overall effects of in-vessel and hot leg natural circulation flows on the plant response. The natural circulation flows extended the transient, slowing the core heatup and delaying core damage by transferring energy from the core to structures in the upper plenum and coolant loops. Increased temperatures in the ex-core structures indicated that they may fail, however. Nine sensitivity calculations were then performed to investigate the effects of modeling uncertainties on the multidimensional natural circulation flows and the system response. Creep rupture failure of the pressurizer surge line was predicted to occur in eight of the calculations, with the hot leg failing in the ninth. The failure time was fairly insensitive to the parameters varied. The failures occurred near the time that fuel rod relocation began, well before failure of the reactor vessel would be expected. A calculation was also performed in which creep rupture failure of the surge line was modeled. The subsequent blowdown led to rapid accumulator injection and quenching of the entire core. 18 refs., 105 figs., 17 tabs

  7. Core damage frequency prespectives for BWR 3/4 and Westinghouse 4-loop plants based on IPE results

    International Nuclear Information System (INIS)

    Dingman, S.; Camp, S.; LaChance, J.; Mary Drouin

    1995-01-01

    This paper discusses the core damage frequency (CDF) insights gained by analyzing the results of the Individual Plant Examinations (IPES) for two groups of plants: boiling water reactor (BWR) 3/4 plants with Reactor Core Isolation Cooling systems, and Westinghouse 4-loop plants. Wide variability was observed for the plant CDFs and for the CDFs of the contributing accident classes. On average, transients-with loss of injection, station blackout sequences, and transients with loss of decay heat removal are important contributors for the BWR 3/4 plants, while transients, station blackout sequences, and loss-of-coolant accidents are important for the Westinghouse 4-loop plants. The key factors that contribute to the variability in the results are discussed. The results are often driven by plant-specific design and operational characteristics, but differences in modeling approaches are also important for some accident classes

  8. 47 CFR 80.389 - Frequencies for maritime support stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Frequencies for maritime support stations. 80.389 Section 80.389 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Frequencies Maritime Support Stations § 80.389...

  9. Development of the APR1400 model for countercurrent natural circulation in hot leg and steam generator under station blackout

    International Nuclear Information System (INIS)

    Park, Sang Gil; Kim, Han Chul

    2012-01-01

    In order to analyze severe accident phenomena, Korea Institute of Nuclear Safety (KINS) made a MELCOR model for APR1400 to examine natural circulation and creep rupture failure in the Reactor Coolant System (RCS) under station blackout (SBO). In this study, we are trying to advance the former model to describe natural circulation more accurately. After Fukushima accident, the concerns of severe accident management, assuring the heat removal capability, has risen for the case when the SBO is happened and there are no more electric powers to cool down decay heat. Under SBO there are three kinds of natural circulation which can delay the core heatup. One is in vessel natural circulation in the upper plenum of reactor vessel and the second is countercurrent natural circulation in hot leg through steam generator tubes and the last is full loop natural circulation when the reactor coolant pump loop seal is cleared and reactor coolant pump sealing is damaged by high temperature and high pressure. Among them this study focuses on the countercurrent natural circulation model using MELCOR1.8.6

  10. Comparative study of the hydrogen generation during short term station blackout (STSBO) in a BWR

    International Nuclear Information System (INIS)

    Polo-Labarrios, M.A.; Espinosa-Paredes, G.

    2015-01-01

    Highlights: • Comparative study of generation in a simulated STSBO severe accident. • MELCOR and SCDAP/RELAP5 codes were used to understanding the main phenomena. • Both codes present similar thermal-hydraulic behavior for pressure and boil off. • SCDAP/RELAP5 predicts 15.8% lower hydrogen production than MELCOR. - Abstract: The aim of this work is the comparative study of hydrogen generation and the associated parameters in a simulated severe accident of a short-term station blackout (STSBO) in a typical BWR-5 with Mark-II containment. MELCOR (v.1.8.6) and SCDAP/RELAP5 (Mod.3.4) codes were used to understand the main phenomena in the STSBO event through the results comparison obtained from simulations with these codes. Due that the simulation scope of SCDAP/RELAP5 is limited to failure of the vessel pressure boundary, the comparison was focused on in-vessel severe accident phenomena; with a special interest in the vessel pressure, boil of cooling, core temperature, and hydrogen generation. The results show that at the beginning of the scenario, both codes present similar thermal-hydraulic behavior for pressure and boil off of cooling, but during the relocation, the pressure and boil off, present differences in timing and order of magnitude. Both codes predict in similar time the beginning of melting material drop to the lower head. As far as the hydrogen production rate, SCDAP/RELAP5 predicts 15.8% lower production than MELCOR

  11. Development of the stationary state and simulation of an accident severe stage type station blackout with the MELCOR code version 1.8.6 for the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Mugica R, C. A.; Godinez S, V.

    2011-11-01

    Considering the events happened since the 11 March of 2011, in Japan, where an earthquake of 9.1 grades Ritcher of intensity and a later tsunami impacted in an important way the operation of a nuclear power plant located in the Fukushima, Japan; damaging and disabling their cooling systems and injection of emergency water due to the total loss of electric power (commonly denominated Station Blackout), is eminent the analysis of this stage type that took to the nuclear power plant to conditions of damage to the core and explosions generation by hydrogen concentrations in the reactor building. In this work an analysis of a stage type station blackout is presented, using the model of the nuclear power plant of Laguna Verde starting of the stationary state. The analysis is carried out using the MELCOR code (Methods for Estimation of Leakages and Consequences of Releases) version 1.8.6 whose purpose is to model the accidents progression for light water reactors. The obtained results are qualitatively similar to the events observed in the Fukushima nuclear power plant even though limitations exist to achieve a precise simulation of the events happened in Japan, such as the information flow of the chronology of the operator actions, as well as of the characteristic design of the power plant, volumes in cavities and rooms, water/cooling inventories, interconnected systems and their own emergency procedures or guides for the administration of severe accidents among others. (Author)

  12. RELAP5/MOD3.3 Analyses of Core Heatup Prevention Strategy During Extended Station Blackout in PWR

    International Nuclear Information System (INIS)

    Prosek, A.

    2016-01-01

    The accident at the Fukushima Dai-ichi nuclear power plant demonstrated the vulnerability of the plants on the loss of electrical power for several days, so called extended station blackout (SBO). A set of measures have been proposed and implemented in response of the accident at the Fukushima Dai-ichi nuclear power plant. The purpose of the study was to investigate the application of the deterministic safety analysis for core heatup prevention strategy of the extended SBO in pressurized water reactor, lasting 72 h. The prevention strategy selected was water injection into steam generators using turbine driven auxiliary feedwater pump (TD-AFW) or portable water injection pump. Method for assessment of the necessary pump injection flowrate is developed and presented. The necessary injection flowrate to the steam generators is determined from the calculated cumulative water mass injected by the turbine driven auxiliary feedwater pump in the analysed scenarios, when desired normal level is maintained automatically. The developed method allows assessment of the necessary injection flowrates of pump, TD-AFW or portable, for different plant configurations and number of flowrate changes. The RELAP5/MOD3.3 Patch04 computer code and input model of a two-loop pressurized water reactor is used for analyses, assuming different injection start times, flowrates and reactor coolant system losses. Three different reactor coolant system (RCS) coolant loss pathways, with corresponding leakage rate, can be expected in the pressurized water reactor (PWR) during the extended SBO: normal system leakage, reactor coolant pump seal leakage, and RCS coolant loss through letdown relief valve unless automatically isolated or until isolation is procedurally directed. Depressurization of RCS was also considered. In total, six types of RCS coolant loss scenarios were considered. Two cases were defined regarding the operation of the emergency diesel generators. Different delays of the pump

  13. Analysis of fuel handling system for fuel bundle safety during station blackout in 500 MWe PHWR unit of India

    International Nuclear Information System (INIS)

    Madhuresh, R.; Nagarajan, R.; Jit, I.; Sanatkumar, A.

    1996-01-01

    Situations of Station Blackout (SBO) i.e. postulated concurrent unavailability of Class Ill and Class IV power, could arise for a long period, while on-power refuelling or other fuel handling operations are in progress with the hot irradiated fuel bundles being anywhere in the system from the Reactor Building to the Spent Fuel Storage Bay. The cooling provisions for these fuel bundles are diverse and specific to the various stages of fuel handling operations and are either on Class Ill or on Class II power with particular requirements of instrument air. Therefore, during SBO, due to the limited availability of Class II power and instrument air, it becomes difficult to maintain cooling to these fuel bundles. However, some minimal cooling is essential, to ensure the safety of the bundles. As discussed in the paper, safety of these fuel bundles in the system and/or for those lying in the liner tube region of the reactor end fitting is ensured, during SBO, by resorting to passive means like 'stay-put', 'gravity- fill', 'D 2 0- steaming' etc. for cooling the bundles. The paper also describes various consequences emanating from these cooling schemes. (author). 6 refs., 2 tabs., 8 figs

  14. Areva T and D market opportunities after the US and EU Blackouts

    Energy Technology Data Exchange (ETDEWEB)

    Hakansson, K

    2004-02-01

    This document presents the events on the transmission systems during August 2003 in Usa and in September 2003 in Italy. The author analyzes the causes of the blackouts (small margins in transmission system, not adequate control, weaknesses in interconnections between regions), the market opportunity arising out of the blackouts, the economic regulatory and environmental structure/issues today and developments, the scenario for Areva after the blackout (the market size today and in the future) and Areva strength in relation to blackout. (A.L.B.) opportunities.

  15. Areva T and D market opportunities after the US and EU Blackouts

    International Nuclear Information System (INIS)

    Hakansson, K.

    2004-02-01

    This document presents the events on the transmission systems during August 2003 in Usa and in September 2003 in Italy. The author analyzes the causes of the blackouts (small margins in transmission system, not adequate control, weaknesses in interconnections between regions), the market opportunity arising out of the blackouts, the economic regulatory and environmental structure/issues today and developments, the scenario for Areva after the blackout (the market size today and in the future) and Areva strength in relation to blackout. (A.L.B.) opportunities

  16. An electromagnetic method for removing the communication blackout with a space vehicle upon re-entry into the atmosphere

    Science.gov (United States)

    Cheng, Jianjun; Jin, Ke; Kou, Yong; Hu, Ruifeng; Zheng, Xiaojing

    2017-03-01

    When a hypersonic vehicle travels in the Earth and Mars atmosphere, the surface of the vehicle is surrounded by a plasma layer, which is an envelope of ionized air, created from the compression and heat of the atmosphere by the shock wave. The vehicles will lose contact with ground stations known as the reentry communication blackout. Based on the magnetohydrodynamic framework and electromagnetic wave propagation theory, an analytical model is proposed to describe the effect of the effectiveness of electromagnetic mitigation scheme on removing the reentry communication blackout. C and Global Positioning System (GPS) bands, two commonly used radio bands for communication, are taken as the cases to discuss the effectiveness of the electromagnetic field mitigation scheme. The results show that the electron density near the antenna of vehicles can be reduced by the electromagnetic field, and the required external magnetic field strength is far below the one in the magnetic window method. The directions of the external electric field and magnetic field have a significant impact on the effectiveness of the mitigation scheme. Furthermore, the effect of electron collisions on the required applied electromagnetic field is discussed, and the result indicates that electron collisions are a key factor to analyze the electromagnetic mitigation scheme. Finally, the feasible regions of the applied electromagnetic field for eliminating blackout are given. These investigations could have a significant benefit on the design and optimization of electromagnetic mitigation scheme for the blackout problem.

  17. Advanced validation of CFD-FDTD combined method using highly applicable solver for reentry blackout prediction

    International Nuclear Information System (INIS)

    Takahashi, Yusuke

    2016-01-01

    An analysis model of plasma flow and electromagnetic waves around a reentry vehicle for radio frequency blackout prediction during aerodynamic heating was developed in this study. The model was validated based on experimental results from the radio attenuation measurement program. The plasma flow properties, such as electron number density, in the shock layer and wake region were obtained using a newly developed unstructured grid solver that incorporated real gas effect models and could treat thermochemically non-equilibrium flow. To predict the electromagnetic waves in plasma, a frequency-dependent finite-difference time-domain method was used. Moreover, the complicated behaviour of electromagnetic waves in the plasma layer during atmospheric reentry was clarified at several altitudes. The prediction performance of the combined model was evaluated with profiles and peak values of the electron number density in the plasma layer. In addition, to validate the models, the signal losses measured during communication with the reentry vehicle were directly compared with the predicted results. Based on the study, it was suggested that the present analysis model accurately predicts the radio frequency blackout and plasma attenuation of electromagnetic waves in plasma in communication. (paper)

  18. Investigation of plasma–surface interaction effects on pulsed electrostatic manipulation for reentry blackout alleviation

    International Nuclear Information System (INIS)

    Krishnamoorthy, S; Close, S

    2017-01-01

    The reentry blackout phenomenon affects most spacecraft entering a dense planetary atmosphere from space, due to the presence of a plasma layer that surrounds the spacecraft. This plasma layer is created by ionization of ambient air due to shock and frictional heating, and in some cases is further enhanced due to contamination by ablation products. This layer causes a strong attenuation of incoming and outgoing electromagnetic waves including those used for command and control, communication and telemetry over a period referred to as the ‘blackout period’. The blackout period may last up to several minutes and is a major contributor to the landing error ellipse at best, and a serious safety hazard in the worst case, especially in the context of human spaceflight. In this work, we present a possible method for alleviation of reentry blackout using electronegative DC pulses applied from insulated electrodes on the reentry vehicle’s surface. We study the reentry plasma’s interaction with a DC pulse using a particle-in-cell (PIC) model. Detailed models of plasma–insulator interaction are included in our simulations. The absorption and scattering of ions and electrons at the plasma–dielectric interface are taken into account. Secondary emission from the insulating surface is also considered, and its implications on various design issues is studied. Furthermore, we explore the effect of changing the applied voltage and the impact of surface physics on the creation and stabilization of communication windows. The primary aim of this analysis is to examine the possibility of restoring L- and S-band communication from the spacecraft to a ground station. Our results provide insight into the effect of key design variables on the response of the plasma to the applied voltage pulse. Simulations show the creation of pockets where electron density in the plasma layer is reduced three orders of magnitude or more in the vicinity of the electrodes. These pockets extend to

  19. Investigation of SAM measures during selected MBLOCA sequences along with Station Blackout in a generic Konvoi PWR using ASTECV2.0

    International Nuclear Information System (INIS)

    Gómez-García-Toraño, Ignacio; Sánchez Espinoza, Víctor Hugo; Stieglitz, Robert

    2017-01-01

    Highlights: • Reflooding is investigated for selected MBLOCA sequences in a Konvoi PWR using ASTEC. • After SBO, there is a grace time of 40 min up to the detection of a CET = 650 °C. • Major core damage prevented if reflood is launched at CET = 650 °C with 25-40 kg/s. • Values depend on the time when the plant is struck by Station Blackout. • Vessel failure cannot be prevented if supplied mass flow rates are lower than 10 kg/s. - Abstract: The Fukushima accidents have shown that further improvement of Severe Accident Management Guidelines (SAMGs) is necessary for the current fleet of Light Water Reactors. The elaboration of SAMGs requires a broad database of deterministic analyses performed with state-of-the art simulation tools. Within this work, the ASTECV2.0 integral severe accident code is used to study the efficiency of core reflooding (as a SAM measure) during postulated Medium Break LOCA (MBLOCA) scenarios in a German Konvoi PWR. In a first step, the progression of selected MBLOCA sequences without SAM measures has been analysed. The sequences postulate a break in the cold leg of the pressurizer loop and the total loss of AC power at a given stage of the accident. Results show the existence of a 40 min grace time up to the detection of a Core Exit Temperature (CET) of 650 °C providing that the AC power has been maintained at least 1 h after SCRAM. In a second step, an extensive analysis on core reflooding has been carried out. The sequences assume that the plant remains in Station Blackout (SBO) and that reflooding occurs at different times with different mobile pumps. The simulations yield the following results: • Reflooding mass flow rates above 60 kg/s have to be supplied as soon as the CET exceeds 650 °C in order to prevent core melting. • Reflooding mass flow rates ranging from 25–40 kg/s at CET = 650 °C mitigate the accident without major core damage depending on when the plant enters in SBO. • Reflooding mass flow rates lower

  20. Analysis of fuel handling system for fuel bundle safety during station blackout in 500 MWe PHWR unit of India

    Energy Technology Data Exchange (ETDEWEB)

    Madhuresh, R; Nagarajan, R; Jit, I; Sanatkumar, A [Nuclear Power Corporation of India Ltd., Mumbai (India)

    1997-12-31

    Situations of Station Blackout (SBO) i.e. postulated concurrent unavailability of Class Ill and Class IV power, could arise for a long period, while on-power refuelling or other fuel handling operations are in progress with the hot irradiated fuel bundles being anywhere in the system from the Reactor Building to the Spent Fuel Storage Bay. The cooling provisions for these fuel bundles are diverse and specific to the various stages of fuel handling operations and are either on Class Ill or on Class II power with particular requirements of instrument air. Therefore, during SBO, due to the limited availability of Class II power and instrument air, it becomes difficult to maintain cooling to these fuel bundles. However, some minimal cooling is essential, to ensure the safety of the bundles. As discussed in the paper, safety of these fuel bundles in the system and/or for those lying in the liner tube region of the reactor end fitting is ensured, during SBO, by resorting to passive means like `stay-put`, `gravity- fill`, `D{sub 2}0- steaming` etc. for cooling the bundles. The paper also describes various consequences emanating from these cooling schemes. (author). 6 refs., 2 tabs., 8 figs.

  1. Alcohol-Induced Memory Blackouts as an Indicator of Injury Risk among College Drinkers

    Science.gov (United States)

    Mundt, Marlon P.; Zakletskaia, Larissa I.; Brown, David D.; Fleming, Michael F.

    2011-01-01

    Objective An alcohol-induced memory blackout represents an amnesia to recall events but does not involve a loss of consciousness. Memory blackouts are a common occurrence among college drinkers, but it is not clear if a history of memory blackouts is predictive of future alcohol-related injury above and beyond the risk associated with heavy drinking episodes. This analysis sought to determine if baseline memory blackouts can prospectively identify college students with alcohol-related injury in the next 24 months after controlling for heavy drinking days. Methods Data were analyzed from the College Health Intervention Project Study (CHIPS), a randomized controlled trial of screening and brief physician intervention for problem alcohol use among 796 undergraduate and 158 graduate students at four university sites in the US and one in Canada, conducted from 2004 to 2009. Multivariate analyses used generalized estimating equations (GEE) with the logit link. Results The overall 24-month alcohol-related injury rate was 25.6%, with no significant difference between males and females (p=.51). Alcohol-induced memory blackouts at baseline exhibited a significant dose-response on odds of alcohol-related injury during follow-up, increasing from 1.57 (95% CI: 1.13–2.19) for subjects reporting 1–2 memory blackouts at baseline to 2.64 (95% CI: 1.65–4.21) for students acknowledging 6+ memory blackouts at baseline. The link between memory blackouts and injury was mediated by younger age, prior alcohol-related injury, heavy drinking, and sensation-seeking disposition. Conclusions Memory blackouts are a significant predictor of future alcohol-related injury among college drinkers after adjusting for heavy drinking episodes. PMID:21708813

  2. Summary of ROSA-4 LSTF first phase test program and station blackout (TMLB) test results

    International Nuclear Information System (INIS)

    Tasaka, K.; Kukita, Y.; Anoda, Y.

    1990-01-01

    This paper summarizes major test results obtained at the ROSA-4 Large Scale Test Facility (LSTF) during the first phase of the test program. The results from a station blackout (TMLB) test conducted at the end of the first-phase program are described in some detail. The LSTF is an integral test facility being operated by the Japan Atomic Energy Research Institute for simulation of pressurized water reactor (PWR) thermal-hydraulic responses during small-break loss-of-coolant accidents (SBLOCAs) and operational/abnormal transients. It is a 1/48 volumetrically scaled, full-height, full-pressure simulator of a Westinghouse-type 4-loop PWR. The facility includes two symmetric primary loops each one containing an active inverted-U tube steam generator and an active reactor coolant pump. The loop horizontal legs are sized to conserve the scaled (1/24) volumes as well as the length to the square root of the diameter ratio in order to simulate the two-phase flow regime transitions. The primary objective of the LSTF first-phase program was to define the fundamental PWR thermal-hydraulic responses during SBLOCAs and transients. Most of the tests were conducted with simulated component/operator failures, including unavailability of the high pressure injection system and auxiliary feedwater system, as well as operator failure to take corrective actions. The forty-two first phase tests included twenty-nine SBLOCA tests conducted mainly for cold leg breaks, three abnormal transient tests and ten natural circulation tests. Attempts were made in several of the SBLOCA tests to simulate the plant recovery procedures as well as candidate accident management measures for prevention of high-pressure core melt situation. The natural circulation tests simulated the single-phase and two-phase natural circulation as well as reflux condensation behavior in the primary loops in steady or quasi-steady states

  3. Computer chaos and the blackout

    CERN Multimedia

    Malik, Rex

    1971-01-01

    A recent electricity dispute resulted in power black-outs with unfortunate consequences for organizations relying on computers. Article discusses the implications of similar events in Britain in the future when computers are even more widely in use (1 1/2 pages).

  4. Impact assessment of the 1977 New York City blackout. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Corwin, J. L.; Miles, W. T.

    1978-07-01

    This study was commissioned by the Division of Electric Energy Systems (EES), Department of Energy (DOE) shortly after the July 13, 1977 New York City Blackout. The objectives were two-fold: to assess the availability and collect, where practical, data pertaining to a wide variety of impacts occurring as a result of the blackout; and to broadly define a framework to assess the value of electric power reliability from consideration of the blackout and its effects on individuals, businesses, and institutions. The impacts were complex and included both economic and social costs. In order to systematically classify the most significant of these impacts and provide guidance for data collection, impact classification schemes were developed. Major economic impact categories examined are business; government; utilities (Consolidated Edison); insurance industry; public health services; and other public services. Impacts were classified as either direct or indirect depending upon whether the impact was due to a cessation of electricity or a response to that cessation. The principal economic costs of the blackout are shown. Social impacts, i.e., the changes in social activities and adaptations to these changes were particularly significant in New York due to its unique demographic and geographic characteristics. The looting and arson that accompanied the blackout set aside the NYC experience from other similar power failures. (MCW)

  5. Evaluation of steam generator U-tube integrity during PWR station blackout with secondary system depressurization

    International Nuclear Information System (INIS)

    Hidaka, Akihide; Asaka, Hideaki; Sugimoto, Jun; Ueno, Shingo; Yoshino, Takehito

    1999-12-01

    In PWR severe accidents such as station blackout, the integrity of steam generator U-tube would be threatened early at the transient among the pipes of primary system. This is due to the hot leg countercurrent natural circulation (CCNC) flow which delivers the decay heat of the core to the structures of primary system if the core temperature increases after the secondary system depressurization. From a view point of accident mitigation, this steam generator tube rupture (SGTR) is not preferable because it results in the direct release of primary coolant including fission products (FP) to the environment. Recent SCDAP/RELAP5 analyses by USNRC showed that the creep failure of pressurizer surge line which results in release of the coolant into containment would occur earlier than SGTR during the secondary system depressurization. However, the analyses did not consider the decay heat from deposited FP on the steam generator U-tube surface. In order to investigate the effect of decay heat on the steam generator U-tube integrity, the hot leg CCNC flow model used in the USNRC's calculation was, at first, validated through the analysis for JAERI's LSTF experiment. The CCNC model reproduced well the thermohydraulics observed in the LSTF experiment and thus the model is mostly reliable. An analytical study was then performed with SCDAP/RELAP5 for TMLB' sequence of Surry plant with and without secondary system depressurization. The decay heat from deposited FP was calculated by JAERI's FP aerosol behavior analysis code, ART. The ART analysis showed that relatively large amount of FPs may deposit on steam generator U-tube inlet mainly by thermophoresis. The SCDAP/RELAP5 analyses considering the FP decay heat predicted small safety margin for steam generator U-tube integrity during secondary system depressurization. Considering associated uncertainties in the analyses, the potential for SGTR cannot be ignored. Accordingly, this should be considered in the evaluation of merits

  6. AP1000 station blackout study with and without depressurization using RELAP5/SCDAPSIM

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, A.K. [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India); Allison, C. [Innovative Systems Software Idaho Falls, ID 83406 (United States); Khanna, A., E-mail: akhanna@iitk.ac.in [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India); Munshi, P. [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India)

    2016-10-15

    Highlights: • A representative RELAP5/SCDAPSIM model of AP1000 has been developed. • Core is modeled using SCDAP. • A SBO for the AP1000 has been simulated for high pressure (no depressurization) and low pressure (depressurization). • Significant differences in the damage progression have been observed for the two cases. • Results also reinforced the fact that surge line fails before vessel failure in case of high pressure scenario. - Abstract: Severe accidents like TMI-2, Chernobyl, Fukushima made it inevitable to analyze station blackout (SBO) for all the old as well as new designs although it is not a regulatory requirement in most of the countries. For such improbable accidents, a SBO for the AP1000 using RELAP5/SCDAPSIM has been simulated. Many improvements have been made in fuel damage progression models of SCDAP after the Fukushima accident which are now being tested for the new reactor designs. AP1000 is a 2-loop pressurized water reactor (PWR) with all the emergency core cooling systems based on natural circulation. Its core design is very similar to 3-loop PWR with 157 fuel assemblies. The primary circuit pumps, pressurizer and steam generators (with necessary secondary side) are modeled using RELAP5. The core has been divided into 20 axial nodes and 6 radial rings; the corresponding six groups of assemblies have been modeled as six pipe components with proportionate flow area. Fuel assemblies are modeled using SCDAP fuel and control components. SCDAP has 2d-heat conduction and radiative heat transfer, oxidation and complete severe fuel damage progression models. The final input deck achieved all the steady state thermal hydraulic conditions comparable to the design control document of AP1000. To quantify the core behavior, under unavailability of all safety systems, various time profiles for SBO simulations @ high pressure and low pressure have been compared. This analysis has been performed for 102% (3468 MWt) of the rated core power. The

  7. Blackouts as a Moderator of Young Adult Veteran Response to Personalized Normative Feedback for Heavy Drinking.

    Science.gov (United States)

    Miller, Mary Beth; DiBello, Angelo M; Carey, Kate B; Pedersen, Eric R

    2018-06-01

    Blackouts-or periods of alcohol-induced amnesia for all or part of a drinking event-have been identified as independent predictors of alcohol-related harm that may be used to identify individuals who would benefit from intervention. However, little is known about the prevalence and impact of blackouts among Veterans. This study examined blackouts as a moderator of young adult veteran response to a brief, online personalized normative feedback (PNF) intervention for heavy drinking. Veterans scoring ≥3/4 (women/men) on the Alcohol Use Disorders Identification Test completed a baseline and 1-month assessment as part of a larger intervention trial (N = 571; 83% male; age M = 28.9, SD = 3.3). Participants were randomized to alcohol PNF (n = 285) or a video game attention control (n = 286). Hierarchical regression was used to examine the interaction between intervention condition and blackouts on alcohol-related outcomes at 1-month follow-up. At baseline, 26% of participants reported loss of memory for drinking events in the past 30 days. The interaction between condition and blackouts was significant, such that PNF participants who had experienced blackouts at baseline reported greater decreases in drinking quantity at 1 month than those who had not, and only PNF participants who had experienced baseline blackouts reported a decrease in alcohol problems at follow-up. PNF appears to be particularly effective for individuals who have experienced alcohol-induced blackout, perhaps because blackouts prime them for feedback on their alcohol use. While other negative consequences may also prime individuals for behavior change, blackouts are posited as a particularly useful screening tool because they are prevalent among young adults, have a strong association with alcohol-related harm, and are assessed in widely used clinical measures. Copyright © 2018 by the Research Society on Alcoholism.

  8. Analysis of core damage frequency from internal events: Surry, Unit 1

    International Nuclear Information System (INIS)

    Harper, F.T.

    1986-11-01

    This document contains the accident sequence analyses for Surry, Unit 1; one of the reference plants being examined as part of the NUREG-1150 effort by the Nuclear Regulatory Commission (NRC). NUREG-1150 will document the risk of a selected group of nuclear power plants. As part of that work, this report contains the overall core damage frequency estimate for Surry, Unit 1, and the accompanying plant damage state frequencies. Sensitivity and uncertainty analyses provide additional insights regarding the dominant contributors to the Surry core damage frequency estimate. The numerical results are driven to some degree by modeling assumptions and data selection for issues such as reactor coolant pump seal LOCAs, common cause failure probabilities, and plant response to station blackout and loss of electrical bust initiators. The sensitivity studies explore the impact of alternate theories and data on these issues

  9. Blackout cloth for dormancy induction

    Science.gov (United States)

    Tom Jopson

    2007-01-01

    The use of blackout cloth to create long night photoperiods for the induction of dormancy in certain conifer species has been an established practice for a long time. Its use was suggested by Tinus and McDonald (1979) as an effective technique, and the practice has been commonly used in Canadian forest nurseries for a number of years. Cal-Forest Nursery installed its...

  10. Learning from the blackouts. Transmission system security in competitive electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    none

    2005-07-01

    Electricity market reform has fundamentally changed the environment for maintaining reliable and secure power supplies. Growing inter-regional trade has placed new demands on transmission systems, creating a more integrated and dynamic network environment with new real-time challenges for reliable and secure transmission system operation. Despite these fundamental changes, system operating rules and practices remain largely unchanged. The major blackouts of 2003 and 2004 raised searching questions about the appropriateness of these arrangements. Management of system security needs to be transformed to maintain reliable electricity services in this more dynamic operating environment. These challenges raise fundamental issues for policymakers. This publication presents case studies drawn from recent large-scale blackouts in Europe, North America, and Australia. It concludes that a comprehensive, integrated policy response is required to avoid preventable large-scale blackouts in the future.

  11. Alcohol-induced blackout as a criminal defense or mitigating factor: an evidence-based review and admissibility as scientific evidence.

    Science.gov (United States)

    Pressman, Mark R; Caudill, David S

    2013-07-01

    Alcohol-related amnesia--alcohol blackout--is a common claim of criminal defendants. The generally held belief is that during an alcohol blackout, other cognitive functioning is severely impaired or absent. The presentation of alcohol blackout as scientific evidence in court requires that the science meets legal reliability standards (Frye, FRE702/Daubert). To determine whether "alcohol blackout" meets these standards, an evidence-based analysis of published scientific studies was conducted. A total of 26 empirical studies were identified including nine in which an alcohol blackout was induced and directly observed. No objective or scientific method to verify the presence of an alcoholic blackout while it is occurring or to confirm its presence retrospectively was identified. Only short-term memory is impaired and other cognitive functions--planning, attention, and social skills--are not impaired. Alcoholic blackouts would not appear to meet standards for scientific evidence and should not be admissible. © 2013 American Academy of Forensic Sciences.

  12. Extended blackout mitigation strategy for PWR

    International Nuclear Information System (INIS)

    Prošek, Andrej; Volkanovski, Andrija

    2015-01-01

    Highlights: • Equipment for mitigation of the extended blackout is investigated. • Analysis is done with deterministic safety analysis methods. • Strategy to prevent core heatup and not overfill steam generator is proposed. • Six types of reactor coolant system loss scenarios are investigated. • Pump flowrates and available start time to feed steam generators is determined. - Abstract: The accident at the Fukushima Daiichi nuclear power plant demonstrated the vulnerability of the plants on the loss of electrical power and loss of the ultimate heat sink events. A set of measures are proposed and currently implemented in response of the accident at the Fukushima Daiichi nuclear power plant. Those measures include diverse and flexible mitigation strategies that increase the defence-in-depth for beyond-design-basis scenarios. Mitigation strategies are based on the utilization of the portable equipment to provide power and water to the nuclear power plants in order to maintain or restore key safety functions. The verification of the proposed measures with the plant specific safety analyses is endorsed in the mitigation strategies. This paper investigates utilization of the turbine driven auxiliary feedwater pump (TD-AFW) or portable water injection pump for the mitigation of the event of loss of all alternate current sources and batteries (extended station blackout). Methodology for assessment of the required pump injection flow rate with the application of the standard deterministic safety analysis code is developed and presented. The required injection rate to the steam generators is calculated from the cumulative water mass injected by the turbine driven auxiliary feedwater pump in the analysed scenarios, when desired normal level is maintained automatically. The developed methodology allows assessment of the required injections rates of pump, TD-AFW or portable, for different plant configurations and number of flow rate changes. The methodology is applied

  13. Extended blackout mitigation strategy for PWR

    Energy Technology Data Exchange (ETDEWEB)

    Prošek, Andrej, E-mail: andrej.prosek@ijs.si; Volkanovski, Andrija, E-mail: andrija.volkanovski@ijs.si

    2015-12-15

    Highlights: • Equipment for mitigation of the extended blackout is investigated. • Analysis is done with deterministic safety analysis methods. • Strategy to prevent core heatup and not overfill steam generator is proposed. • Six types of reactor coolant system loss scenarios are investigated. • Pump flowrates and available start time to feed steam generators is determined. - Abstract: The accident at the Fukushima Daiichi nuclear power plant demonstrated the vulnerability of the plants on the loss of electrical power and loss of the ultimate heat sink events. A set of measures are proposed and currently implemented in response of the accident at the Fukushima Daiichi nuclear power plant. Those measures include diverse and flexible mitigation strategies that increase the defence-in-depth for beyond-design-basis scenarios. Mitigation strategies are based on the utilization of the portable equipment to provide power and water to the nuclear power plants in order to maintain or restore key safety functions. The verification of the proposed measures with the plant specific safety analyses is endorsed in the mitigation strategies. This paper investigates utilization of the turbine driven auxiliary feedwater pump (TD-AFW) or portable water injection pump for the mitigation of the event of loss of all alternate current sources and batteries (extended station blackout). Methodology for assessment of the required pump injection flow rate with the application of the standard deterministic safety analysis code is developed and presented. The required injection rate to the steam generators is calculated from the cumulative water mass injected by the turbine driven auxiliary feedwater pump in the analysed scenarios, when desired normal level is maintained automatically. The developed methodology allows assessment of the required injections rates of pump, TD-AFW or portable, for different plant configurations and number of flow rate changes. The methodology is applied

  14. Analyzing mobile WiMAX base station deployment under different frequency planning strategies

    Science.gov (United States)

    Salman, M. K.; Ahmad, R. B.; Ali, Ziad G.; Aldhaibani, Jaafar A.; Fayadh, Rashid A.

    2015-05-01

    The frequency spectrum is a precious resource and scarce in the communication markets. Therefore, different techniques are adopted to utilize the available spectrum in deploying WiMAX base stations (BS) in cellular networks. In this paper several types of frequency planning techniques are illustrated, and a comprehensive comparative study between conventional frequency reuse of 1 (FR of 1) and fractional frequency reuse (FFR) is presented. These techniques are widely used in network deployment, because they employ universal frequency (using all the available bandwidth) in their base station installation/configuration within network system. This paper presents a network model of 19 base stations in order to be employed in the comparison of the aforesaid frequency planning techniques. Users are randomly distributed within base stations, users' resource mapping and their burst profile selection are based on the measured signal to interference plus-noise ratio (SINR). Simulation results reveal that the FFR has advantages over the conventional FR of 1 in various metrics. 98 % of downlink resources (slots) are exploited when FFR is applied, whilst it is 81 % at FR of 1. Data rate of FFR has been increased to 10.6 Mbps, while it is 7.98 Mbps at FR of 1. The spectral efficiency is better enhanced (1.072 bps/Hz) at FR of 1 than FFR (0.808 bps/Hz), since FR of 1 exploits all the Bandwidth. The subcarrier efficiency shows how many data bits that can be carried by subcarriers under different frequency planning techniques, the system can carry more data bits under FFR (2.40 bit/subcarrier) than FR of 1 (1.998 bit/subcarrier). This study confirms that FFR can perform better than conventional frequency planning (FR of 1) which made it a strong candidate for WiMAX BS deployment in cellular networks.

  15. The Rising Frequency of IT Blackouts Indicates the Increasing Relevance of IT Emergency Concepts to Ensure Patient Safety.

    Science.gov (United States)

    Sax, Ulrich; Lipprandt, M; Röhrig, R

    2016-11-10

    As many medical workflows depend vastly on IT support, great demands are placed on the availability and accuracy of the applications involved. The cases of IT failure through ransomware at the beginning of 2016 are impressive examples of the dependence of clinical processes on IT. Although IT risk management attempts to reduce the risk of IT blackouts, the probability of partial/total data loss, or even worse, data falsification, is not zero. The objective of this paper is to present the state of the art with respect to strategies, processes, and governance to deal with the failure of IT systems. This article is conducted as a narrative review. Worst case scenarios are needed, dealing with methods as to how to survive the downtime of clinical systems, for example through alternative workflows. These workflows have to be trained regularly. We categorize the most important types of IT system failure, assess the usefulness of classic counter measures, and state that most risk management approaches fall short on exactly this matter. To ensure that continuous, evidence-based improvements to the recommendations for IT emergency concepts are made, it is essential that IT blackouts and IT disasters are reported, analyzed, and critically discussed. This requires changing from a culture of shame and blame to one of error and safety in healthcare IT. This change is finding its way into other disciplines in medicine. In addition, systematically planned and analyzed simulations of IT disaster may assist in IT emergency concept development.

  16. Severe accident sequences simulated at the Grand Gulf Nuclear Station

    International Nuclear Information System (INIS)

    Carbajo, J.J.

    1999-01-01

    Different severe accident sequences employing the MELCOR code, version 1.8.4 QK, have been simulated at the Grand Gulf Nuclear Station (Grand Gulf). The postulated severe accidents simulated are two low-pressure, short-term, station blackouts; two unmitigated small-break (SB) loss-of-coolant accidents (LOCAs) (SBLOCAs); and one unmitigated large LOCA (LLOCA). The purpose of this study was to calculate best-estimate timings of events and source terms for a wide range of severe accidents and to compare the plant response to these accidents

  17. Acute alcohol effects on narrative recall and contextual memory: an examination of fragmentary blackouts.

    Science.gov (United States)

    Wetherill, Reagan R; Fromme, Kim

    2011-08-01

    The present study examined the effects of alcohol consumption on narrative recall and contextual memory among individuals with and without a history of fragmentary blackouts in an attempt to better understand why some individuals experience alcohol-induced memory impairments whereas others do not, even at comparable blood alcohol concentrations (BACs). Standardized beverage (alcohol and no alcohol) administration procedures and neuropsychological assessments measured narrative recall and context memory performance before and after alcohol consumption in individuals with (n=44) and without (n=44) a history of fragmentary blackouts. Findings indicate that acute alcohol intoxication led to impairments in free recall, but not next-day cued recall. Further, participants showed similar memory performance when sober, but individuals who consumed alcohol and had a positive history of fragmentary blackouts showed greater contextual memory impairments than those who had not previously experienced a fragmentary blackout. Thus, it appears that some individuals may have an inherent vulnerability to alcohol-induced memory impairments due to alcohol's effects on contextual memory processes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. A STRONGLY COUPLED REACTOR CORE ISOLATION COOLING SYSTEM MODEL FOR EXTENDED STATION BLACK-OUT ANALYSES

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Haihua [Idaho National Laboratory; Zhang, Hongbin [Idaho National Laboratory; Zou, Ling [Idaho National Laboratory; Martineau, Richard Charles [Idaho National Laboratory

    2015-03-01

    The reactor core isolation cooling (RCIC) system in a boiling water reactor (BWR) provides makeup cooling water to the reactor pressure vessel (RPV) when the main steam lines are isolated and the normal supply of water to the reactor vessel is lost. The RCIC system operates independently of AC power, service air, or external cooling water systems. The only required external energy source is from the battery to maintain the logic circuits to control the opening and/or closure of valves in the RCIC systems in order to control the RPV water level by shutting down the RCIC pump to avoid overfilling the RPV and flooding the steam line to the RCIC turbine. It is generally considered in almost all the existing station black-out accidents (SBO) analyses that loss of the DC power would result in overfilling the steam line and allowing liquid water to flow into the RCIC turbine, where it is assumed that the turbine would then be disabled. This behavior, however, was not observed in the Fukushima Daiichi accidents, where the Unit 2 RCIC functioned without DC power for nearly three days. Therefore, more detailed mechanistic models for RCIC system components are needed to understand the extended SBO for BWRs. As part of the effort to develop the next generation reactor system safety analysis code RELAP-7, we have developed a strongly coupled RCIC system model, which consists of a turbine model, a pump model, a check valve model, a wet well model, and their coupling models. Unlike the traditional SBO simulations where mass flow rates are typically given in the input file through time dependent functions, the real mass flow rates through the turbine and the pump loops in our model are dynamically calculated according to conservation laws and turbine/pump operation curves. A simplified SBO demonstration RELAP-7 model with this RCIC model has been successfully developed. The demonstration model includes the major components for the primary system of a BWR, as well as the safety

  19. Verification of voltage/ frequency requirement for emergency diesel generator in nuclear power plant using dynamic modeling

    International Nuclear Information System (INIS)

    Hur, J.S.; Roh, M.S.

    2013-01-01

    Full-text: One major cause of the plant shutdown is the loss of electrical power. The study is to comprehend the coping action against station blackout including emergency diesel generator, sequential loading of safety system and to ensure that the emergency diesel generator should meet requirements, especially voltage and frequency criteria using modeling tool. This paper also considered the change of the sequencing time and load capacity only for finding electrical design margin. However, the revision of load list must be verified with safety analysis. From this study, it is discovered that new load calculation is a key factor in EDG localization and in-house capability increase. (author)

  20. Re-evaluation of Station Blackout in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eunchan; Shin, Taeyoung [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2014-05-15

    This paper proposes a reduction of the uncertainty due to the small number of LOOP events and an estimation of the non-recovery probability after a LOOP event where the operators fail to energize a safety bus using the offsite power recovery during an SBO with recent operating experience. In addition, in this analysis, the CDF is re-evaluated through reflecting the enhancement of the Class-1E battery capacity. For newly constructed KHNP plants, the LOOP frequency and non-recovery probability after a LOOP during an SBO were re-evaluated through integrating the KHNP events into generic data containing broader experiences for PSA. For an initiating event frequency, a new LOOP frequency was calculated through a Bayesian update of the KHNP LOOP frequency using NUREG/CR-6890, which reflects the recent trends and has a large data size. For the non-recovery probability estimation, domestic data were added to the American experiences in the NUREG/CR-6890; these data were fitted to a lognormal distribution in order to reduce the uncertainty due to the small size of the KHNP data. Regarding the battery capacity enhancement, the success criteria during an SBO were re-evaluated considering the longer battery duty time. The CDF was recalculated using the resultant available time for operator action. The changed CDF was reduced by approximately 50% compared with the value before battery improvement. In conclusion, it was quantitatively proven that enlarging the battery capacity to manage SBOs positively affected plant safety. In addition, methods to improve data uncertainty due to the small number of experiences were selected in order to evaluate the LOOP frequency and non-recovery probability after a LOOP for future plants. These efforts contribute to obtaining a realistic risk profile and to prioritizing countermeasures and improvements of vulnerabilities for safety.

  1. Analysis of core damage frequency: Surry, Unit 1 internal events

    International Nuclear Information System (INIS)

    Bertucio, R.C.; Julius, J.A.; Cramond, W.R.

    1990-04-01

    This document contains the accident sequence analysis of internally initiated events for the Surry Nuclear Station, Unit 1. This is one of the five plant analyses conducted as part of the NUREG-1150 effort by the Nuclear Regulatory Commission. NUREG-1150 documents the risk of a selected group of nuclear power plants. The work performed and described here is an extensive of that published in November 1986 as NUREG/CR-4450, Volume 3. It addresses comments form numerous reviewers and significant changes to the plant systems and procedures made since the first report. The uncertainty analysis and presentation of results are also much improved. The context and detail of this report are directed toward PRA practitioners who need to know how the work was performed and the details for use in further studies. The mean core damage frequency at Surry was calculated to be 4.05-E-5 per year, with a 95% upper bound of 1.34E-4 and 5% lower bound of 6.8E-6 per year. Station blackout type accidents (loss of all AC power) were the largest contributors to the core damage frequency, accounting for approximately 68% of the total. The next type of dominant contributors were Loss of Coolant Accidents (LOCAs). These sequences account for 15% of core damage frequency. No other type of sequence accounts for more than 10% of core damage frequency. 49 refs., 52 figs., 70 tabs

  2. Resonant interaction of electromagnetic wave with plasma layer and overcoming the radiocommunication blackout problem

    Science.gov (United States)

    Bogatskaya, A. V.; Klenov, N. V.; Tereshonok, M. V.; Adjemov, S. S.; Popov, A. M.

    2018-05-01

    We present an analysis of the possibility of penetrating electromagnetic waves through opaque media using an optical-mechanical analogy. As an example, we consider the plasma sheath surrounding the vehicle as a potential barrier and analyze the overcoming of radiocommunication blackout problem. The idea is to embed a «resonator» between the surface on the vehicle and plasma sheath which is supposed to provide an effective tunneling of the signal to the receiving antenna. We discuss the peculiarities of optical mechanical analogy applicability and analyze the radio frequency wave tunneling regime in detail. The cases of normal and oblique incidence of radiofrequency waves on the vehicle surface are studied.

  3. An uncertainty analysis of the hydrogen source term for a station blackout accident in Sequoyah using MELCOR 1.8.5

    Energy Technology Data Exchange (ETDEWEB)

    Gauntt, Randall O.; Bixler, Nathan E.; Wagner, Kenneth Charles.

    2014-03-01

    A methodology for using the MELCOR code with the Latin Hypercube Sampling method was developed to estimate uncertainty in various predicted quantities such as hydrogen generation or release of fission products under severe accident conditions. In this case, the emphasis was on estimating the range of hydrogen sources in station blackout conditions in the Sequoyah Ice Condenser plant, taking into account uncertainties in the modeled physics known to affect hydrogen generation. The method uses user-specified likelihood distributions for uncertain model parameters, which may include uncertainties of a stochastic nature, to produce a collection of code calculations, or realizations, characterizing the range of possible outcomes. Forty MELCOR code realizations of Sequoyah were conducted that included 10 uncertain parameters, producing a range of in-vessel hydrogen quantities. The range of total hydrogen produced was approximately 583kg 131kg. Sensitivity analyses revealed expected trends with respected to the parameters of greatest importance, however, considerable scatter in results when plotted against any of the uncertain parameters was observed, with no parameter manifesting dominant effects on hydrogen generation. It is concluded that, with respect to the physics parameters investigated, in order to further reduce predicted hydrogen uncertainty, it would be necessary to reduce all physics parameter uncertainties similarly, bearing in mind that some parameters are inherently uncertain within a range. It is suspected that some residual uncertainty associated with modeling complex, coupled and synergistic phenomena, is an inherent aspect of complex systems and cannot be reduced to point value estimates. The probabilistic analyses such as the one demonstrated in this work are important to properly characterize response of complex systems such as severe accident progression in nuclear power plants.

  4. Analysis of core damage frequency, Surry, Unit 1 internal events appendices

    International Nuclear Information System (INIS)

    Bertucio, R.C.; Julius, J.A.; Cramond, W.R.

    1990-04-01

    This document contains the appendices for the accident sequence analyses of internally initiated events for the Surry Nuclear Station, Unit 1. This is one of the five plant analyses conducted as part of the NUREG-1150 effort by the Nuclear Regulatory Commission. NUREG-1150 documents the risk of a selected group of nuclear power plants. The work performed is an extensive reanalysis of that published in November 1986 as NUREG/CR-4450, Volume 3. It addresses comments from numerous reviewers and significant changes to the plant systems and procedures made since the first report. The uncertainty analysis and presentation of results are also much improved. The context and detail of this report are directed toward PRA practitioners who need to know how the work was performed and the details for use in further studies. The mean core damage frequency at Surry was calculated to be 4.0E-5 per year, with a 95% upper bound of 1.3E-4 and 5% lower bound of 6.8E-6 per year. Station blackout type accidents (loss of all AC power) were the largest contributors to the core damage frequency, accounting for approximately 68% of the total. The next type of dominant contributors were Loss of Coolant Accidents (LOCAs). These sequences account for 15% of core damage frequency. No other type of sequence accounts for more than 10% of core damage frequency

  5. Effect of mobile phone station on micronucleus frequency and chromosomal aberrations in human blood cells.

    Science.gov (United States)

    Yildirim, M S; Yildirim, A; Zamani, A G; Okudan, N

    2010-01-01

    The use of mobile telephones has rapidly increased worldwide as well as the number of mobile phone base stations that lead to rise low level radiofrequency emissions which may in turn have possible harm for human health. The national radiation protection board has published the known effects of radio waves exposure on humans living close to mobile phone base stations. However, several studies have claimed that the base station has detrimental effects on different tissues. In this study, we aimed to evaluate the effects of mobile phone base stations on the micronucleus (MN) frequency and chromosomal aberrations on blood in people who were living around mobile phone base stations and healthy controls. Frequency of MN and chromosomal aberrations in study and control groups was 8.96 +/- 3.51 and 6.97 +/- 1.52 (p: 0.16); 0.36 +/- 0.31 and 0.75 +/- 0.61 (p: 0.07), respectively. Our results show that there was not a significant difference of MN frequency and chromosomal aberrations between the two study groups. The results claim that cellular phones and their base stations do not produce important carcinogenic changes.

  6. Additional examination on station blackout caused by tsunami in Fukushima Daiichi NPS

    International Nuclear Information System (INIS)

    Yamauchi, Daisuke; Date, Kenji; Mizokami, Masato; Honda, Takeshi; Nozaki, Kenichiro; Mizokami, Shinya; Endo, Ryohei

    2017-01-01

    This study is additional examination to verify in a more reliable way the assessment that the emergency AC power supply was lost due to tsunami at Fukushima Daiichi Nuclear Power Station. It confirmed the relationship between the path length of tsunami intrusion reaching each power supply facility and the function loss time. As a result of examination, it was confirmed that as the path length of the tsunami intrusion reaching each power supply facility was longer, the function loss time tended to be later. So, conventional assessment that the function of each power supply facility was lost due to the run-up and flooding of tsunami has become more probable. For facilities, where the overall trend and the loss time of function were divergent, it was found that there were scenarios that could reasonably be explained. Based on the fact that the Fukushima Daiichi Nuclear Power Station lost power due to the tsunami, Kashiwazaki-Kariwa Nuclear Power Station carries out various safety measures. First of all, as the measures to prevent accidents caused by tsunami, the following have been applied: (1) prevention of the inflow of tsunamis into premises, (2) water prevention of the areas installed with important equipment, (3) securement of seawater at the time of backwashing, (4) storage of portable equipment at high ground, (5) installation of tsunami surveillance cameras. To prepare for the loss of power supply, this station implemented power supply facilities such as generator cars and distribution boards, as well as the placement of power supply cars at high ground. (A.O.)

  7. Sustainability from the Occurrence of Critical Dynamic Power System Blackout Determined by Using the Stochastic Event Tree Technique

    Directory of Open Access Journals (Sweden)

    Muhammad Murtadha Othman

    2017-06-01

    Full Text Available With the advent of advanced technology in smart grid, the implementation of renewable energy in a stressed and complicated power system operation, aggravated by a competitive electricity market and critical system contingencies, this will inflict higher probabilities of the occurrence of a severe dynamic power system blackout. This paper presents the proposed stochastic event tree technique used to assess the sustainability against the occurrence of dynamic power system blackout emanating from implication of critical system contingencies such as the rapid increase in total loading condition and sensitive initial transmission line tripping. An extensive analysis of dynamic power system blackout has been carried out in a case study of the following power systems: IEEE RTS-79 and IEEE RTS-96. The findings have shown that the total loading conditions and sensitive transmission lines need to be given full attention by the utility to prevent the occurrence of dynamic power system blackout.

  8. Exchange of pressurizer safeguarding system at Biblis nuclear power station

    International Nuclear Information System (INIS)

    Weber, D.; Hofbeck, W.

    1991-01-01

    Valves and piping of the pressurizer safeguarding system are exchanged and reset in such a way that they are suitable not only for discharging steam, but also for discharging a water-steam mixture and hot pressurized water; for the emergency measure of primary depressurization by hand (bleed) in the event of failure of the entire feedwater supply and station black-out, and in the event of operational transients with supposed failure of the reactor scram (ATWS). To achieve this, in addition to the requirements of the pressurizer discharging station, changes have to be made to the valve drive to dominate the water loads. During the 1990 inspection this exchange of the pressurizer discharging station was performed at the Biblis A unit as the first German plant. (orig.) [de

  9. Cognitive Blackouts in Mild Cognitive Impairment and Alzheimer’s Dementia

    Directory of Open Access Journals (Sweden)

    Georg Adler

    2018-02-01

    Full Text Available Background: Cognitive blackouts, e.g. moments of amnesia, disorientation, or perplexity may be an early sign of incipient Alzheimer’s dementia (AD. A short questionnaire, the checklist for cognitive blackouts (CCB, was evaluated cross-sectionally in users of a memory clinic. Methods: The CCB was performed in 130 subjects, who further underwent a neuropsychological and clinical examination. Subjective memory impairment and depressive symptoms were assessed. Differences in the CCB score between diagnostic groups and relationships with cognitive performance, depression, and subjective memory impairment were analyzed. Results: The CCB score was increased in mild cognitive impairment of the amnestic type or mild AD and correctly predicted 69.2% of the respective subjects. It was negatively correlated with cognitive performance, positively correlated with depressive symptoms, and substantially increased in subjects who estimated their memory poorer than that of other persons of their age. Discussion: The CCB may be a helpful screening tool for the early recognition of AD.

  10. Emergency diesel generator reliability program

    International Nuclear Information System (INIS)

    Serkiz, A.W.

    1989-01-01

    The need for an emergency diesel generator (EDG) reliability program has been established by 10 CFR Part 50, Section 50.63, Loss of All Alternating Current Power, which requires that utilities assess their station blackout duration and recovery capability. EDGs are the principal emergency ac power sources for coping with a station blackout. Regulatory Guide 1.155, Station Blackout, identifies a need for (1) an EDG reliability equal to or greater than 0.95, and (2) an EDG reliability program to monitor and maintain the required levels. The resolution of Generic Safety Issue (GSI) B-56 embodies the identification of a suitable EDG reliability program structure, revision of pertinent regulatory guides and Tech Specs, and development of an Inspection Module. Resolution of B-56 is coupled to the resolution of Unresolved Safety Issue (USI) A-44, Station Blackout, which resulted in the station blackout rule, 10 CFR 50.63 and Regulatory Guide 1.155, Station Blackout. This paper discusses the principal elements of an EDG reliability program developed for resolving GSI B-56 and related matters

  11. Europe's electrical vulnerability geography : historical interpretations of the 2006 'European blackout'

    NARCIS (Netherlands)

    Vleuten, van der E.B.A.; Lagendijk, V.C.

    2009-01-01

    The so-called "European Blackout" of 4 November 2006 counts as a key example of present day transnational infrastructure vulnerability and an important reference in current debates on transnational electricity infrastructure governance. This is best examplified by the debate itself, where proponents

  12. Transnational infrastructure vulnerability : the historical shaping of the 2006 European 'blackout'

    NARCIS (Netherlands)

    Vleuten, van der E.B.A.; Lagendijk, V.C.

    2010-01-01

    The "European Blackout" of 4 November 2006 is a key reference in current debates on transnational electricity infrastructure vulnerability and governance. Several commentators have observed that to understand what happened, one must look at history. Our paper answers this call and demonstrates how

  13. Radio frequency electromagnetic field compliance assessment of multi-band and MIMO equipped radio base stations.

    Science.gov (United States)

    Thors, Björn; Thielens, Arno; Fridén, Jonas; Colombi, Davide; Törnevik, Christer; Vermeeren, Günter; Martens, Luc; Joseph, Wout

    2014-05-01

    In this paper, different methods for practical numerical radio frequency exposure compliance assessments of radio base station products were investigated. Both multi-band base station antennas and antennas designed for multiple input multiple output (MIMO) transmission schemes were considered. For the multi-band case, various standardized assessment methods were evaluated in terms of resulting compliance distance with respect to the reference levels and basic restrictions of the International Commission on Non-Ionizing Radiation Protection. Both single frequency and multiple frequency (cumulative) compliance distances were determined using numerical simulations for a mobile communication base station antenna transmitting in four frequency bands between 800 and 2600 MHz. The assessments were conducted in terms of root-mean-squared electromagnetic fields, whole-body averaged specific absorption rate (SAR) and peak 10 g averaged SAR. In general, assessments based on peak field strengths were found to be less computationally intensive, but lead to larger compliance distances than spatial averaging of electromagnetic fields used in combination with localized SAR assessments. For adult exposure, the results indicated that even shorter compliance distances were obtained by using assessments based on localized and whole-body SAR. Numerical simulations, using base station products employing MIMO transmission schemes, were performed as well and were in agreement with reference measurements. The applicability of various field combination methods for correlated exposure was investigated, and best estimate methods were proposed. Our results showed that field combining methods generally considered as conservative could be used to efficiently assess compliance boundary dimensions of single- and dual-polarized multicolumn base station antennas with only minor increases in compliance distances. © 2014 Wiley Periodicals, Inc.

  14. Branch-and-Bound algorithm applied to uncertainty quantification of a Boiling Water Reactor Station Blackout

    International Nuclear Information System (INIS)

    Nielsen, Joseph; Tokuhiro, Akira; Hiromoto, Robert; Tu, Lei

    2015-01-01

    state. Dynamic PRA (DPRA) methods provide a more rigorous analysis of complex dynamic systems. Unfortunately DPRA methods introduce issues associated with combinatorial explosion of states. This paper presents a methodology to address combinatorial explosion using a Branch-and-Bound algorithm applied to Dynamic Event Trees (DET), which utilize LENDIT (L – Length, E – Energy, N – Number, D – Distribution, I – Information, and T – Time) as well as a set theory to describe system, state, resource, and response (S2R2) sets to create bounding functions for the DET. The optimization of the DET in identifying high probability failure branches is extended to create a Phenomenological Identification and Ranking Table (PIRT) methodology to evaluate modeling parameters important to safety of those failure branches that have a high probability of failure. The PIRT can then be used as a tool to identify and evaluate the need for experimental validation of models that have the potential to reduce risk. In order to demonstrate this methodology, a Boiling Water Reactor (BWR) Station Blackout (SBO) case study is presented.

  15. Branch-and-Bound algorithm applied to uncertainty quantification of a Boiling Water Reactor Station Blackout

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Joseph, E-mail: joseph.nielsen@inl.gov [Idaho National Laboratory, 1955 N. Fremont Avenue, P.O. Box 1625, Idaho Falls, ID 83402 (United States); University of Idaho, Department of Mechanical Engineering and Nuclear Engineering Program, 1776 Science Center Drive, Idaho Falls, ID 83402-1575 (United States); Tokuhiro, Akira [University of Idaho, Department of Mechanical Engineering and Nuclear Engineering Program, 1776 Science Center Drive, Idaho Falls, ID 83402-1575 (United States); Hiromoto, Robert [University of Idaho, Department of Computer Science, 1776 Science Center Drive, Idaho Falls, ID 83402-1575 (United States); Tu, Lei [University of Idaho, Department of Mechanical Engineering and Nuclear Engineering Program, 1776 Science Center Drive, Idaho Falls, ID 83402-1575 (United States)

    2015-12-15

    state. Dynamic PRA (DPRA) methods provide a more rigorous analysis of complex dynamic systems. Unfortunately DPRA methods introduce issues associated with combinatorial explosion of states. This paper presents a methodology to address combinatorial explosion using a Branch-and-Bound algorithm applied to Dynamic Event Trees (DET), which utilize LENDIT (L – Length, E – Energy, N – Number, D – Distribution, I – Information, and T – Time) as well as a set theory to describe system, state, resource, and response (S2R2) sets to create bounding functions for the DET. The optimization of the DET in identifying high probability failure branches is extended to create a Phenomenological Identification and Ranking Table (PIRT) methodology to evaluate modeling parameters important to safety of those failure branches that have a high probability of failure. The PIRT can then be used as a tool to identify and evaluate the need for experimental validation of models that have the potential to reduce risk. In order to demonstrate this methodology, a Boiling Water Reactor (BWR) Station Blackout (SBO) case study is presented.

  16. Millstone 3 risk evaluation report. An overall review and evaluation of the Millstone Unit 3 probabilistic safety study

    International Nuclear Information System (INIS)

    Kelly, G.; Barrett, R.; Buslik, A.

    1986-06-01

    In 1981, the US Nuclear Regulatory Commission (NRC) requested Northeast Utilities to perform a design-specific probabilistic safety study (PSS) for Millstone Nuclear Power Station, Unit No. 3 (Millstone 3). In 1983, Northeast Utilities submitted the Millstone 3 Probabilistic Safety Study for review by the NRC staff. The NRC staff prepared the Millstone 3 Risk Evaluation Report, which discusses the findings regarding the PSS. The PSS estimates that the mean annual core damage frequency due to internal and external events is 5 x 10 -5 and 2 x 10 -5 , respectively. The NRC staff's Risk Evaluation Report estimates that the mean annual core damage frequency is about 2 x 10 -4 for internal events and lies between 1 x 10 -5 and 2 x 10 -4 for external events. The NRC staff estimates that station blackout dominates internal and external event core damage frequencies. The staff recommends that Northeast Utilities perform an engineering analysis on upgrading the diesel generator lube oil cooler anchorage system and on adding a manually operated, AC-independent containment spray system. The staff also recommends that Northeast Utilities prepare two emergency procedures (loss of room cooling and relay chatter due to an earthquake) to help reduce uncertainties. (Subsequent to the completion of this document, Northeast Utilities and the NRC staff have continued a dialogue regarding station blackout from events other than earthquakes. Both Northeast Utilities and the staff have performed additional evaluations, which have drawn their results closer together. Final requirements, if any, for the prevention or mitigation of station blackout from events other than earthquakes have not yet been determined.) 26 refs., 16 tabs

  17. Optimization of station battery replacement

    International Nuclear Information System (INIS)

    Jancauskas, J.R.; Shook, D.A.

    1994-01-01

    During a loss of ac power at a nuclear generating station (including diesel generators), batteries provide the source of power which is required to operate safety-related components. Because traditional lead-acid batteries have a qualified life of 20 years, the batteries must be replaced a minimum of once during a station's lifetime, twice if license extension is pursued, and more often depending on actual in-service dates and the results of surveillance tests. Replacement of batteries often occurs prior to 20 years as a result of systems changes caused by factors such as Station Blackout Regulations, control system upgrades, incremental load growth, and changes in the operating times of existing equipment. Many of these replacement decisions are based on the predictive capabilities of manual design basis calculations. The inherent conservatism of manual calculations may result in battery replacements occurring before actually required. Computerized analysis of batteries can aid in optimizing the timing of replacements as well as in interpreting service test data. Computerized analysis also provides large benefits in maintaining the as-configured load profile and corresponding design margins, while also providing the capability of quickly analyze proposed modifications and response to internal and external audits

  18. Analysis of core damage frequency from internal events: Peach Bottom, Unit 2

    International Nuclear Information System (INIS)

    Kolaczkowski, A.M.; Lambright, J.A.; Ferrell, W.L.; Cathey, N.G.; Najafi, B.; Harper, F.T.

    1986-10-01

    This document contains the internal event initiated accident sequence analyses for Peach Bottom, Unit 2; one of the reference plants being examined as part of the NUREG-1150 effort by the Nuclear Regulatory Commission. NUREG-1150 will document the risk of a selected group of nuclear power plants. As part of that work, this report contains the overall core damage frequency estimate for Peach Bottom, Unit 2, and the accompanying plant damage state frequencies. Sensitivity and uncertainty analyses provided additional insights regarding the dominant contributors to the Peach Bottom core damage frequency estimate. The mean core damage frequency at Peach Bottom was calculated to be 8.2E-6. Station blackout type accidents (loss of all ac power) were found to dominate the overall results. Anticipated Transient Without Scram accidents were also found to be non-negligible contributors. The numerical results are largely driven by common mode failure probability estimates and to some extent, human error. Because of significant data and analysis uncertainties in these two areas (important, for instance, to the most dominant scenario in this study), it is recommended that the results of the uncertainty and sensitivity analyses be considered before any actions are taken based on this analysis

  19. Review of Leading Approaches for Mitigating Hypersonic Vehicle Communications Blackout and a Method of Ceramic Particulate Injection Via Cathode Spot Arcs for Blackout Mitigation

    Science.gov (United States)

    Gillman, Eric D.; Foster, John E.; Blankson, Isaiah M.

    2010-01-01

    Vehicles flying at hypersonic velocities within the atmosphere become enveloped in a "plasma sheath" that prevents radio communication, telemetry, and most importantly, GPS signal reception for navigation. This radio "blackout" period has been a problem since the dawn of the manned space program and was an especially significant hindrance during the days of the Apollo missions. An appropriate mitigation method must allow for spacecraft to ground control and ground control to spacecraft communications through the reentry plasma sheath. Many mitigation techniques have been proposed, including but not limited to, aerodynamic shaping, magnetic windows, and liquid injection. The research performed on these mitigation techniques over the years will be reviewed and summarized, along with the advantages and obstacles that each technique will need to overcome to be practically implemented. A unique approach for mitigating the blackout communications problem is presented herein along with research results associated with this method. The novel method involves the injection of ceramic metal-oxide particulate into a simulated reentry plasma to quench the reentry plasma. Injection of the solid ceramic particulates is achieved by entrainment within induced, energetic cathode spot flows.

  20. Emergency makeup of nuclear steam generators in blackout conditions

    International Nuclear Information System (INIS)

    Korolev, A.V.; Derevyanko, O.V.

    2014-01-01

    The paper describes an original solution for using steam energy to organize makeup of NPP steam generators in blackout conditions. The proposed solution combines a disk friction turbine and an axial turbine in a single housing to provide a high overall technical effect enabling the replenishment of nuclear steam generators with steam using the pump turbine drive assembly. The application of the design is analyzed and its efficiency and feasibility are shown

  1. Nuclear energy + solar energy, why not?

    International Nuclear Information System (INIS)

    Hernandez C, I.; Nelson E, P.

    2016-09-01

    Clean energies such as nuclear and solar are part of the solution to the energy dependence that we face today and also help us to reduce the greenhouse gas emissions, thus avoiding a global average temperature increase that is irreversible and harmful to all living beings on the planet. Independently the nuclear and solar energies have had a great development in recent years, so in this work we set ourselves the task of creating a synergy between them. First, we conducted a survey of different people involved in the area of energy (energy efficiency, clean energy and renewable sources) in order to know if the area of which they are part influences with respect to the impression that they have of safety in terms of supply, return on investment and safety to the health and environment of another energy source for which we use a correlation analysis. With the results obtained we propose to use photo thermic solar energy as a support to reduce the frequency of accidents by station blackout and we perform the analysis of the combination using the methodology of Probabilistic Analysis of Security with the help of SAPHIRE 7 software to realize the event trees by station blackout of a nuclear power plant and faults for a photo-thermal solar plant. Finally, the decrease in the probability of station blackout from the proposed combination is quantified. The results were favorable to indicate that the probability of station blackout is reduced in half and that is why is suggested to continue studying the combination. (Author)

  2. Nuclear energy + solar energy, why not?; Energia nuclear + energia solar, por que no?

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez C, I.; Nelson E, P., E-mail: ihernandezc91@hotmail.com [UNAM, Facultad de Ingenieria, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico)

    2016-09-15

    Clean energies such as nuclear and solar are part of the solution to the energy dependence that we face today and also help us to reduce the greenhouse gas emissions, thus avoiding a global average temperature increase that is irreversible and harmful to all living beings on the planet. Independently the nuclear and solar energies have had a great development in recent years, so in this work we set ourselves the task of creating a synergy between them. First, we conducted a survey of different people involved in the area of energy (energy efficiency, clean energy and renewable sources) in order to know if the area of which they are part influences with respect to the impression that they have of safety in terms of supply, return on investment and safety to the health and environment of another energy source for which we use a correlation analysis. With the results obtained we propose to use photo thermic solar energy as a support to reduce the frequency of accidents by station blackout and we perform the analysis of the combination using the methodology of Probabilistic Analysis of Security with the help of SAPHIRE 7 software to realize the event trees by station blackout of a nuclear power plant and faults for a photo-thermal solar plant. Finally, the decrease in the probability of station blackout from the proposed combination is quantified. The results were favorable to indicate that the probability of station blackout is reduced in half and that is why is suggested to continue studying the combination. (Author)

  3. Study on LOOP and SBO Frequency for Multi-Unit PSA

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kyung Ho; Heo, Gyun Young [Kyunghee University, Yongin (Korea, Republic of)

    2016-05-15

    In conventional single unit PSA, it was assumed that all accidents or events are independent and the risk of only one unit has been evaluated. In other words, the possibility that simultaneous events occur on multiple units was excluded because it was assumed that the probability of concurrent events were extremely low. After Fukushima accidents, however, it was found that external hazards such as tsunami may impact on multiple units; that means, for the sake of proper mitigation the risk of accidents in shared SSCs should be reevaluated. New risk metrics to improve conventional CDF (Core Damage frequency) based on reactor-year is needed to perform MUPSA (Multi-Unit Probabilistic Safety Assessment). IAEA suggested SCDF (Site CDF) as a risk metrics for MUPSA. The frequency based on reactor-year was converted to the frequency based on site-year. In addition, shared SSCs were modeled in single unit PSA as if those units have independent shared SSCs. Therefore, the risk of shared SSCs should be reevaluated. In this paper, the frequency of LOOP (Loss of Offsite Power), which is typically a multi-unit event, was evaluated and the frequency of SBO (Station Blackout) depending on LOOP frequency and emergency power systems such as EDG (Emergency Diesel Generator) and AAC (Alternate AC), that can mitigate SBO events, was modeled. This paper describes how to calculate LOOP and SBO frequency from the simple example for two-unit site with shared AAC. The events impacting on multiple units, which were excluded in conventional PSA, should be considered for MUPSA.

  4. Thermal-hydraulic analysis of NSSS and containment response during extended station blackout for Maanshan PWR plant

    Energy Technology Data Exchange (ETDEWEB)

    Yuann, Yng-Ruey, E-mail: ryyuann@iner.gov.tw; Hsu, Keng-Hsien, E-mail: hardlycampus@iner.gov.tw; Lin, Chin-Tsu, E-mail: jtling@iner.gov.tw

    2015-07-15

    Highlights: • Calculate NSSS and containment transient response during extended SBO of 24 h. • RELAP5-3D and GOTHIC models are developed for Maanshan PWR plant. • Reactor coolant pump seal leakage is specifically modeled for each loop. • Analyses are performed with and without secondary-side depressurization, respectively. • Considering different total available time for turbine driven auxiliary feedwater system. - Abstract: A thermal-hydraulic analysis has been performed with respect to the response of the nuclear steam supply system (NSSS) and the containment during an extended station blackout (SBO) duration of 24 h in Maanshan PWR plant. Maanshan plant is a Westinghouse three-loop PWR design with rated core thermal power of 2822 MWt. The analyses in the NSSS and the containment are based on the RELAP5-3D and GOTHIC models, respectively. Important design features of the plant in response to SBO are considered in the respective models, e.g., the steam generator PORVs, turbine driven auxiliary feedwater system (TDAFWS), accumulators, reactor coolant pump (RCP) seal design, various heat structures in the containment, etc. In the analysis it is assumed that the shaft seal in each RCP failed due to loss of seal cooling and the RCS fluid flows to the containment directly. Some parameters calculated from the RELPA5-3D model are input to the containment GOTHIC model, including the RCS average temperature and the RCP seal leakage flow and enthalpy. The RCS average temperature is used to drive the sensible heat transfer to the containment. It is found that the severity of the event depends mainly on whether the secondary side is depressurized or not. If the secondary side is depressurized in time (within 1 h after SBO) and the TDAFWS is available greater than 19 h, then the reactor core will be covered with water throughout the SBO duration, which ensures the integrity of the reactor core. On the contrary, if the secondary side is not depressurized, then the RCS

  5. THE APPLICATION OF MAMMOTH FOR A DETAILED TIGHTLY COUPLED FUEL PIN SIMULATION WITH A STATION BLACKOUT

    Energy Technology Data Exchange (ETDEWEB)

    Gleicher, Frederick; Ortensi, Javier; DeHart, Mark; Wang, Yaqi; Schunert, Sebastian; Novascone, Stephen; Hales, Jason; Williamson, Rich; Slaughter, Andrew; Permann, Cody; Andrs, David; Martineau, Richard

    2016-09-01

    Accurate calculation of desired quantities to predict fuel behavior requires the solution of interlinked equations representing different physics. Traditional fuels performance codes often rely on internal empirical models for the pin power density and a simplified boundary condition on the cladding edge. These simplifications are performed because of the difficulty of coupling applications or codes on differing domains and mapping the required data. To demonstrate an approach closer to first principles, the neutronics application Rattlesnake and the thermal hydraulics application RELAP-7 were coupled to the fuels performance application BISON under the master application MAMMOTH. A single fuel pin was modeled based on the dimensions of a Westinghouse 17x17 fuel rod. The simulation consisted of a depletion period of 1343 days, roughly equal to three full operating cycles, followed by a station blackout (SBO) event. The fuel rod was depleted for 1343 days for a near constant total power loading of 65.81 kW. After 1343 days the fission power was reduced to zero (simulating a reactor shut-down). Decay heat calculations provided the time-varying energy source after this time. For this problem, Rattlesnake, BISON, and RELAP-7 are coupled under MAMMOTH in a split operator approach. Each system solves its physics on a separate mesh and, for RELAP-7 and BISON, on only a subset of the full problem domain. Rattlesnake solves the neutronics over the whole domain that includes the fuel, cladding, gaps, water, and top and bottom rod holders. Here BISON is applied to the fuel and cladding with a 2D axi-symmetric domain, and RELAP-7 is applied to the flow of the circular outer water channel with a set of 1D flow equations. The mesh on the Rattlesnake side can either be 3D (for low order transport) or 2D (for diffusion). BISON has a matching ring structure mesh for the fuel so both the power density and local burn up are copied accurately from Rattlesnake. At each depletion time

  6. Risk analysis of NPP in multi-unit site for configuration of AAC power source

    International Nuclear Information System (INIS)

    Kim, Myung Ki

    2000-01-01

    Because of the difficulties in finding new sites for nuclear power plants, more units are being added to the existing sites. In these multi-unit sites, appropriate countermeasures should be established to cope with the potential station blackout (SBO) accident. Currently, installation of additional diesel generator (DG) is considered to ensure an alternative AC power source, but it has not been decided yet how many DGs should be installed in a multi-unit site. In this paper, risk informed decision making method, which evaluates reliability of electrical system, core damage frequency, and site average core damage frequency, is introduced to draw up the suitable number of DG in multi-unit site. The analysis results show that installing two DGs lowered the site average core damage frequency by 1.4% compared to one DG in six unit site. In the light of risk-informed decisions in regulatory guide 1.174, there is no difference of safety between two alternatives. It is concluded that one emergency diesel generator sufficiently guarantees safety against station blackout of nuclear power plants in multi-unit site. (author)

  7. Performance Evaluation of Target Detection with a Near-Space Vehicle-Borne Radar in Blackout Condition.

    Science.gov (United States)

    Li, Yanpeng; Li, Xiang; Wang, Hongqiang; Deng, Bin; Qin, Yuliang

    2016-01-06

    Radar is a very important sensor in surveillance applications. Near-space vehicle-borne radar (NSVBR) is a novel installation of a radar system, which offers many benefits, like being highly suited to the remote sensing of extremely large areas, having a rapidly deployable capability and having low vulnerability to electronic countermeasures. Unfortunately, a target detection challenge arises because of complicated scenarios, such as nuclear blackout, rain attenuation, etc. In these cases, extra care is needed to evaluate the detection performance in blackout situations, since this a classical problem along with the application of an NSVBR. However, the existing evaluation measures are the probability of detection and the receiver operating curve (ROC), which cannot offer detailed information in such a complicated application. This work focuses on such requirements. We first investigate the effect of blackout on an electromagnetic wave. Performance evaluation indexes are then built: three evaluation indexes on the detection capability and two evaluation indexes on the robustness of the detection process. Simulation results show that the proposed measure will offer information on the detailed performance of detection. These measures are therefore very useful in detecting the target of interest in a remote sensing system and are helpful for both the NSVBR designers and users.

  8. Examples of extremely low-frequency magnetic fields in a Finnish metro station

    International Nuclear Information System (INIS)

    Korpinen, L.; Sydaenheimo, L.; Laehdetie, A.; Amundin, A.; Piippo, H.

    2015-01-01

    The aim of this pilot study was to present examples of extremely low-frequency (ELF) magnetic fields in a Finnish metro station. The metro trains are powered by 750 V DC voltage supplied through a conductor rail next to the running rails. We measured magnetic fields with a magnetic field meter MFM 3000 in 17 cases when a train was leaving the platform in the same metro station. The maximum measured magnetic field was 5400 nT (at 1 m height and 4.3 m from the conductor rail). The magnetic field stayed at this level for a very short time after the metro left the platform. It is possible that there are also DC magnetic fields near the metro as the train leaves the station because the trains are powered by DC voltage. Therefore, it is also important to measure DC fields and DC currents in the future. (authors)

  9. Lightning rod ionizing natural ionca - Ionic electrode active trimetallictriac of grounding - Definitive and total solution against 'blackouts' and electrical faults generated by atmospheric charges (lightning)

    Energy Technology Data Exchange (ETDEWEB)

    Cabareda, Luis

    2010-09-15

    The Natural Ionizing System of Electrical Protection conformed by: Lightning Rod Ionizing Natural Ionca and Ionic Electrode Active Trimetallic Triac of Grounding offers Total Protection, Maximum Security and Zero Risk to Clinics, Hospitals, Integral Diagnostic Center, avoiding ''the burning'' of Electronics Cards; Refineries, Tanks and Stations of Fuel Provision; Electrical Substations, Towers and Transmission Lines with transformer protection, motors, elevators, A/C, mechanicals stairs, portable and cooling equipment, electrical plants, others. This New High Technology is the solution to the paradigm of Benjamin Franklin and it's the mechanism to end the 'Blackouts' that produces so many damages and losses throughout the world.

  10. High-Tech, Low-Tech, No-Tech: Communications Strategies During Blackouts

    Science.gov (United States)

    2013-12-01

    straight-line “ derecho ”1 windstorms hit the mid-Atlantic region of the United States. In the National Capital Region (NCR), many residents lost...flooding (Grand Forks, North Dakota, 1997), rolling blackouts (California, 2001), multi-state power outage (Ohio and seven other 1 “ Derecho ” is a...flawlessly throughout the 2012 “super- derecho ”20 storm event.21 During its 2012 typhoon, the government of the Philippines used Twitter to

  11. Analysis of flood-magnitude and flood-frequency data for streamflow-gaging stations in the Delaware and North Branch Susquehanna River Basins in Pennsylvania

    Science.gov (United States)

    Roland, Mark A.; Stuckey, Marla H.

    2007-01-01

    The Delaware and North Branch Susquehanna River Basins in Pennsylvania experienced severe flooding as a result of intense rainfall during June 2006. The height of the flood waters on the rivers and tributaries approached or exceeded the peak of record at many locations. Updated flood-magnitude and flood-frequency data for streamflow-gaging stations on tributaries in the Delaware and North Branch Susquehanna River Basins were analyzed using data through the 2006 water year to determine if there were any major differences in the flood-discharge data. Flood frequencies for return intervals of 2, 5, 10, 50, 100, and 500 years (Q2, Q5, Q10, Q50, Q100, and Q500) were determined from annual maximum series (AMS) data from continuous-record gaging stations (stations) and were compared to flood discharges obtained from previously published Flood Insurance Studies (FIS) and to flood frequencies using partial-duration series (PDS) data. A Wilcoxon signed-rank test was performed to determine any statistically significant differences between flood frequencies computed from updated AMS station data and those obtained from FIS. Percentage differences between flood frequencies computed from updated AMS station data and those obtained from FIS also were determined for the 10, 50, 100, and 500 return intervals. A Mann-Kendall trend test was performed to determine statistically significant trends in the updated AMS peak-flow data for the period of record at the 41 stations. In addition to AMS station data, PDS data were used to determine flood-frequency discharges. The AMS and PDS flood-frequency data were compared to determine any differences between the two data sets. An analysis also was performed on AMS-derived flood frequencies for four stations to evaluate the possible effects of flood-control reservoirs on peak flows. Additionally, flood frequencies for three stations were evaluated to determine possible effects of urbanization on peak flows. The results of the Wilcoxon signed

  12. Can the complex networks help us in the resolution of the problem of power outages (blackouts) in Brazil?

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Paulo Alexandre de; Souza, Thaianne Lopes de [Universidade Federal de Goias (UFG), Catalao, GO (Brazil)

    2011-07-01

    Full text. What the Brazilian soccer championship, Hollywood actors, the network of the Internet, the spread of viruses and electric distribution network have in common? Until less than two decade ago, the answer would be 'nothing' or 'almost nothing'. However, the answer today to this same question is 'all' or 'almost all'. The answer to these questions and more can be found through a sub-area of statistical physics | called science of complex networks that has been used to approach and study the most diverse natural and non-natural systems, such as systems/social networks, information, technological or biological. In this work we study the distribution network of electric power in Brazil (DEEB), from a perspective of complex networks, where we associate stations and/or substations with a network of vertices and the links between the vertices we associate with the transmission lines. We are doing too a comparative study with the best-known models of complex networks, such as Erdoes-Renyi, Configuration Model and Barabasi-Albert, and then we compare with results obtained in real electrical distribution networks. Based on this information, we do a comparative analysis using the following variables: connectivity distribution, diameter, clustering coefficient, which are frequently used in studies of complex networks. We emphasize that the main objective of this study is to analyze the robustness of the network DEEB, and then propose alternatives for network connectivity, which may contribute to the increase of robustness in maintenance projects and/or expansion of the network, in other words our goal is to make the network to proof the blackouts or improve the endurance the network against the blackouts. For this purpose, we use information from the structural properties of networks, computer modeling and simulation. (author)

  13. Swiss Solutions for Providing Electrical Power in Cases of Long-Term Black-Out of the Grid

    International Nuclear Information System (INIS)

    Altkind, Franz; Schmid, Daniel

    2015-01-01

    A better understanding of nuclear power plant electrical system robustness and defence-in-depth may be derived from comparing design and operating practices in member countries. In pursuing this goal, the current paper will focus on Switzerland. It will present in general the protective measures implemented in the Swiss nuclear power plants to ensure power supply, which comply with the 'Defence-in-depth' principle by means of several layers of protection. In particular it will present the measures taken in case of a total station blackout. The different layers supplying electricity may be summed up as follows. The first layer consists of the external main grid, which the plant generators feed into. The second layer is the auxiliary power supply when the power plant is in island mode in case of a failure of the main grid. A third layer is provided by the external reserve grid in case of both a failure of the external main grid and of the auxiliary power supply in island mode. As a fourth layer there exists an emergency electrical power supply. This is supplied either from an emergency diesel generator or a direct feed from a hydroelectric power plant. In the fifth layer, the special emergency electrical power supply from bunkered emergency diesel generators power the special emergency safety system and is activated upon the loss of all external feeds. A sixth layer consists of accident management equipment. Since the Fukushima event, the sixth layer has been reinforced and a seventh layer with off-site accident management equipment has been newly added. The Swiss nuclear safety regulator has analysed the accident. It reviewed the Swiss plants' protection against earthquakes as well as flooding and demanded increased precautionary measures from the Swiss operators in the hypothetical case of a total station blackout, when all the first five layers of supply would fail. In the immediate, a centralized storage with severe accident management equipment

  14. Adaptive Tuning of Frequency Thresholds Using Voltage Drop Data in Decentralized Load Shedding

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Faria Da Silva, Filipe Miguel; Bak, Claus Leth

    2015-01-01

    Load shedding (LS) is the last firewall and the most expensive control action against power system blackout. In the conventional under frequency LS (UFLS) schemes, the load drop locations are already determined independently of the event location. Furthermore, the frequency thresholds of LS relays...... are prespecified and constant values which may not be a comprehensive solution for widespread range of possible events. This paper addresses the decentralized LS in which the instantaneous voltage deviation of load buses is used to determine the frequency thresholds of LS relays. The higher frequency thresholds...

  15. Observing power blackouts from space - A disaster related study

    Science.gov (United States)

    Aubrecht, C.; Elvidge, C. D.; Ziskin, D.; Baugh, K. E.; Tuttle, B.; Erwin, E.; Kerle, N.

    2009-04-01

    In case of emergency disaster managers worldwide require immediate information on affected areas and estimations of the number of affected people. Natural disasters such as earthquakes, hurricanes, tornados, wind and ice storms often involve failures in the electrical power generation system and grid. Near real time identification of power blackouts gives a first impression of the area affected by the event (Elvidge et al. 2007), which can subsequently be linked to population estimations. Power blackouts disrupt societal activities and compound the difficulties associated with search and rescue, clean up, and the provision of food and other supplies following a disastrous event. Locations and spatial extents of power blackouts are key considerations in planning and execution of the primary disaster missions of emergency management organizations. To date only one satellite data source has been used successfully for the detection of power blackouts. Operated by NOAA's National Geophysical Data Center (NGDC) the U.S. Air Force Defense Meteorological Satellite Program (DMSP) Operational Linescan System (OLS) offers a unique capability to observe lights present at the Earth's surface at night. Including a pair of visible and thermal spectral bands and originally designed to detect moonlit clouds, this sensor enables mapping of lights from cities and towns, gas flares and offshore platforms, fires, and heavily lit fishing boats. The low light imaging of the OLS is accomplished using a photomultiplier tube (PMT) which intensifies the visible band signal at night. With 14 orbits collected per day and a 3.000 km swath width, each OLS is capable of collecting a complete set of images of the Earth every 24 hours. NGDC runs the long-term archive for OLS data with the digital version extending back to 1992. OLS data is received by NGDC in near real time (1-2 hours from acquisition) and subscription based services for the near real time data are provided for users all over the

  16. The 4 november 2006 blackout: an outage of 'technical' democracy?

    International Nuclear Information System (INIS)

    Leteurtrois, J.P.

    2007-01-01

    With its power plants and exportation of electricity to neighboring lands, France imagined that it was sheltered from blackouts. But in the autumn of 2006, five million French households were deprived of electricity due to an error by a German operator. What to think of this? The internationalization of the electricity market, though useful to consumers, should not mean deregulation or the relinquishment of rules and regulations to power companies. Supervision of the grid must be reinforced on behalf of all European users of electricity. (author)

  17. Sinister synergies : how competition for unregulated profit causes blackouts

    International Nuclear Information System (INIS)

    Wilson, J.

    2005-01-01

    This white paper examined the effects of deregulation on electricity system reliability and demonstrated that the pursuit of unregulated profit has increased blackout risk. It was suggested that although deregulation works well in some areas, experts, studies and experience have shown that the deregulation of the electricity system has failed. The make-up of the electricity system was discussed, as well as the importance of the system to security, safety, health and economic well-being. It was suggested that higher costs and the need for greater profits have pushed deregulated power producers to cut costs drastically and to invest where high, short-term returns are more likely, rather than focusing on reasonable long-term returns with reasonable cost savings and reliability. In addition, the complexity of deregulated electricity markets has afforded participants many opportunities to manipulate and cut corners to increase profits. It was suggested that higher costs and the need for higher profits have combined with deregulated market conditions to provide motives and opportunities for a culture of bad behavior. This has cost consumers billions of dollars and resulted in increased blackout risk. It was noted that there have also been significant cut-backs in training, maintenance and rehabilitation, as well as in research. There has been a large increase in the complexity of deregulated systems because of increased numbers of participants, transactions and relationships, which has led to the introduction of new systems without appropriate testing, pilot projects, risk management, gradual implementation and backup procedures. It was concluded that an independent investigation should be carried out, and that a major study is needed to examine deregulated environments. 31 refs

  18. 77 FR 16175 - Station Blackout

    Science.gov (United States)

    2012-03-20

    ... of the near- term actions based on lessons-learned stemming from the March 2011 Fukushima Dai-ichi... http://www.regulations.gov and search for documents filed under Docket ID NRC- 2011-0299. Address.... Fukushima Dai-ichi Event and the NRC Regulatory Response III. Background A. General Design Criteria 2 and 17...

  19. Silencing Boko Haram: Mobile Phone Blackout and Counterinsurgency in Nigeria’s Northeast region

    Directory of Open Access Journals (Sweden)

    Jacob Udo-Udo Jacob

    2015-03-01

    Full Text Available In the summer of 2013, the Nigerian military, as part of its counterinsurgency operations against Boko Haram insurgents, shut down GSM mobile telephony in three northeast states – Adamawa, Borno and Yobe. This article explores the rationale, impact and citizens’ opinion of the mobile phone blackout. It draws on focus group discussions with local opinion leaders and in-depth personal interviews with military and security insiders, as well as data of Boko Haram incidences before, during and after the blackout from military sources and conflict databases. It argues that, although the mobile phone shutdown was ‘successful’ from a military- tactical point of view, it angered citizens and engendered negative opinions toward the state and new emergency policies. While citizens developed various coping and circumventing strategies, Boko Haram evolved from an open network model of insurgency to a closed centralized system, shifting the center of its operations to the Sambisa Forest. This fundamentally changed the dynamics of the conflict. The shutdown demonstrated, among others, that while ICTs serve various desirable purposes for developing states, they will be jettisoned when their use challenges the state’s legitimacy and raison d'être, but not without consequences.

  20. Interpreting transnational infrastructure vulnerability: European blackout and the historical dynamics of transnational electricity governance

    International Nuclear Information System (INIS)

    Vleuten, Erik van der; Lagendijk, Vincent

    2010-01-01

    Recent transnational blackouts exposed two radically opposed interpretations of Europe's electricity infrastructure, which inform recent and ongoing negotiations on transnational electricity governance. To EU policy makers such blackouts revealed the fragility of Europe's power grids and the need of a more centralized form of governance, thus legitimizing recent EU interventions. Yet to power sector spokespersons, these events confirmed the reliability of transnational power grids and the traditional decentralized governance model: the disturbances were quickly contained and repaired. This paper inquires the historic legacies at work in these conflicting interpretations and associated transnational governance preferences. It traces the power sector's interpretation to its building of a secure transnational power grid from the 1950s through the era of neoliberalization. Next it places the EU interpretation and associated policy measures against the historical record of EU attempts at transnational infrastructure governance. Uncovering the historical roots and embedding of both interpretations, we conclude that their divergence is of a surprisingly recent date and relates to the current era of security thinking. Finally we recommend transnational, interpretative, and historical analysis to the field of critical infrastructure studies.

  1. An in situ measurement of the radio-frequency attenuation in ice at Summit Station, Greenland

    OpenAIRE

    Avva, J.; Kovac, J. M.; Miki, C.; Saltzberg, D.; Vieregg, A. G.

    2014-01-01

    We report an in situ measurement of the electric field attenuation length Lα at radio frequencies for the bulk ice at Summit Station, Greenland, made by broadcasting radio-frequency signals vertically through the ice and measuring the relative power in the return ground bounce signal. We find the depth-averaged field attenuation length to be hLαi = 947+92 −85 m at 75 MHz. While this measurement has clear radioglaciological applications, the radio clarity of the ice also has implications for t...

  2. An adaptive reentry guidance method considering the influence of blackout zone

    Science.gov (United States)

    Wu, Yu; Yao, Jianyao; Qu, Xiangju

    2018-01-01

    Reentry guidance has been researched as a popular topic because it is critical for a successful flight. In view that the existing guidance methods do not take into account the accumulated navigation error of Inertial Navigation System (INS) in the blackout zone, in this paper, an adaptive reentry guidance method is proposed to obtain the optimal reentry trajectory quickly with the target of minimum aerodynamic heating rate. The terminal error in position and attitude can be also reduced with the proposed method. In this method, the whole reentry guidance task is divided into two phases, i.e., the trajectory updating phase and the trajectory planning phase. In the first phase, the idea of model predictive control (MPC) is used, and the receding optimization procedure ensures the optimal trajectory in the next few seconds. In the trajectory planning phase, after the vehicle has flown out of the blackout zone, the optimal reentry trajectory is obtained by online planning to adapt to the navigation information. An effective swarm intelligence algorithm, i.e. pigeon inspired optimization (PIO) algorithm, is applied to obtain the optimal reentry trajectory in both of the two phases. Compared to the trajectory updating method, the proposed method can reduce the terminal error by about 30% considering both the position and attitude, especially, the terminal error of height has almost been eliminated. Besides, the PIO algorithm performs better than the particle swarm optimization (PSO) algorithm both in the trajectory updating phase and the trajectory planning phases.

  3. Characterization of weakly ionized argon flows for radio blackout mitigation experiments

    Science.gov (United States)

    Steffens, L.; Koch, U.; Esser, B.; Gülhan, A.

    2017-06-01

    For reproducing the so-called E × B communication blackout mitigation scheme inside the L2K arc heated facility of the DLR in weakly ionized argon §ows, a §at plate model has been equipped with a superconducting magnet, electrodes, and a setup comprising microwave plasma transmission spectroscopy (MPTS). A thorough characterization of the weakly ionized argon §ow has been performed including the use of microwave interferometry (MWI), Langmuir probe measurements, Pitot probe pro¦les, and spectroscopic methods like diode laser absorption spectroscopy (DLAS) and emission spectroscopy.

  4. Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

    Energy Technology Data Exchange (ETDEWEB)

    Hedayat, Afshin [Reactor and Nuclear Safety School, Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of)

    2017-08-15

    In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank), safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal–hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.

  5. Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

    Directory of Open Access Journals (Sweden)

    Afshin Hedayat

    2017-08-01

    Full Text Available In this paper, a complete station blackout (SBO or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR. The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank, safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal–hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.

  6. Analysis of core damage frequency: Peach Bottom, Unit 2 internal events appendices

    International Nuclear Information System (INIS)

    Kolaczkowski, A.M.; Cramond, W.R.; Sype, T.T.; Maloney, K.J.; Wheeler, T.A.; Daniel, S.L.

    1989-08-01

    This document contains the appendices for the accident sequence analysis of internally initiated events for the Peach Bottom, Unit 2 Nuclear Power Plant. This is one of the five plant analyses conducted as part of the NUREG-1150 effort for the Nuclear Regulatory Commission. The work performed and described here is an extensive reanalysis of that published in October 1986 as NUREG/CR-4550, Volume 4. It addresses comments from numerous reviewers and significant changes to the plant systems and procedures made since the first report. The uncertainty analysis and presentation of results are also much improved, and considerable effort was expended on an improved analysis of loss of offsite power. The content and detail of this report is directed toward PRA practitioners who need to know how the work was done and the details for use in further studies. The mean core damage frequency is 4.5E-6 with 5% and 95% uncertainty bounds of 3.5E-7 and 1.3E-5, respectively. Station blackout type accidents (loss of all ac power) contributed about 46% of the core damage frequency with Anticipated Transient Without Scram (ATWS) accidents contributing another 42%. The numerical results are driven by loss of offsite power, transients with the power conversion system initially available operator errors, and mechanical failure to scram. 13 refs., 345 figs., 171 tabs

  7. Modelling of blackout sequence at Atucha-1 using the MARCH3 code

    International Nuclear Information System (INIS)

    Baron, J.; Bastianelli, B.

    1997-01-01

    This paper presents the modelling of a complete blackout at the Atucha-1 NPP as preliminary phase for a Level II safety probabilistic analysis. The MARCH3 code of the STCP (Source Term Code Package) is used, based on a plant model made in accordance with particularities of the plant design. The analysis covers all the severe accident phases. The results allow to view the time sequence of the events, and provide the basis for source term studies. (author). 6 refs., 2 figs

  8. Assessment of Radio-Frequency Radiation Exposure Level from Selected Mobile Base Stations (MBS) in Lokoja, Kogi State, Nigeria

    OpenAIRE

    Nwankwo, U. J. Victor; Jibiri, N. N.; Dada, S. S.; Onugba, A. A.; Ushie, P.

    2012-01-01

    The acquisition and use of mobile phone is tremendously increasing especially in developing countries, but not without a concern. The greater concern among the public is principally over the proximity of mobile base stations (MBS) to residential areas rather than the use of handsets. In this paper, we present an assessment of Radio-Frequency (RF) radiation exposure level measurements and analysis of radiation power density (in W/sq m) from mobile base stations relative to radial distance (in ...

  9. Acute Alcohol Effects on Narrative Recall and Contextual Memory: An Examination of Fragmentary Blackouts

    OpenAIRE

    Wetherill, Reagan R.; Fromme, Kim

    2011-01-01

    The present study examined the effects of alcohol consumption on narrative recall and contextual memory among individuals with and without a history of fragmentary blackouts in an attempt to better understand why some individuals experience alcohol-induced memory impairments whereas others do not, even at comparable blood alcohol concentrations (BACs). Standardized beverage (alcohol, no alcohol) administration procedures and neuropsychological assessments measured narrative recall and context...

  10. Binge Drinking and the Young Brain: A Mini Review of the Neurobiological Underpinnings of Alcohol-Induced Blackout

    Directory of Open Access Journals (Sweden)

    Daniel F. Hermens

    2018-01-01

    Full Text Available Binge drinking has significant effects on memory, particularly with regards to the transfer of information to long-term storage. Partial or complete blocking of memory formation is known as blackout. Youth represents a critical period in brain development that is particularly vulnerable to alcohol misuse. Animal models show that the adolescent brain is more vulnerable to the acute and chronic effects of alcohol compared with the adult brain. This mini-review addresses the neurobiological underpinnings of binge drinking and associated memory loss (blackout in the adolescent and young adult period. Although the extent to which there are pre-existing versus alcohol-induced neurobiological changes remains unclear, it is likely that repetitive binge drinking in youth has detrimental effects on cognitive and social functioning. Given its role in learning and memory, the hippocampus is a critical region with neuroimaging research showing notable changes in this structure associated with alcohol misuse in young people. There is a great need for earlier identification of biological markers associated with alcohol-related brain damage. As a means to assess in vivo neurochemistry, magnetic resonance spectroscopy (MRS has emerged as a particularly promising technique since changes in neurometabolites often precede gross structural changes. Thus, the current paper addresses how MRS biomarkers of neurotransmission (glutamate, GABA and oxidative stress (indexed by depleted glutathione in the hippocampal region of young binge drinkers may underlie propensity for blackouts and other memory impairments. MRS biomarkers may have particular utility in determining the acute versus longer-term effects of binge drinking in young people.

  11. Compliance boundaries for multiple-frequency base station antennas in three directions.

    Science.gov (United States)

    Thielens, Arno; Vermeeren, Günter; Kurup, Divya; Joseph, Wout; Martens, Luc

    2013-09-01

    In this article, compliance boundaries and allowed output powers are determined for the front, back, and side of multiple-frequency base station antennas, based on the root-mean-squared electric field, the whole-body averaged specific absorption rate (SAR), and the 10 g averaged SAR in both the limbs and the head and trunk. For this purpose, the basic restrictions and reference levels defined by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) for both the general public and occupational exposure are used. The antennas are designed for Global System for Mobile Communications around 900 MHz (GSM900), GSM1800, High Speed Packet Access (HSPA), and Long Term Evolution (LTE), and are operated with output powers at the individual frequencies up to 300 W. The compliance boundaries are estimated using finite-difference time-domain simulations with the Virtual Family Male and have been determined for three directions with respect to the antennas for 800, 900, 1800, and 2600 MHz. The reference levels are not always conservative when the radiating part of the antenna is small compared to the length of the body. Combined compliance distances, which ensure compliance with all reference levels and basic restrictions, have also been determined for each frequency. A method to determine a conservative estimation of compliance boundaries for multiple-frequency (cumulative) exposure is introduced. Using the errors on the estimated allowed powers, an uncertainty analysis is carried out for the compliance distances. Uncertainties on the compliance distances are found to be smaller than 122%. Copyright © 2013 Wiley Periodicals, Inc.

  12. Blackout risk prevention in a smart grid based flexible optimal strategy using Grey Wolf-pattern search algorithms

    International Nuclear Information System (INIS)

    Mahdad, Belkacem; Srairi, K.

    2015-01-01

    Highlights: • A generalized optimal security power system planning strategy for blackout risk prevention is proposed. • A Grey Wolf Optimizer dynamically coordinated with Pattern Search algorithm is proposed. • A useful optimized database dynamically generated considering margin loading stability under severe faults. • The robustness and feasibility of the proposed strategy is validated in the standard IEEE 30 Bus system. • The proposed planning strategy will be useful for power system protection coordination and control. - Abstract: Developing a flexible and reliable power system planning strategy under critical situations is of great importance to experts and industrials to minimize the probability of blackouts occurrence. This paper introduces the first stage of this practical strategy by the application of Grey Wolf Optimizer coordinated with pattern search algorithm for solving the security smart grid power system management under critical situations. The main objective of this proposed planning strategy is to prevent the practical power system against blackout due to the apparition of faults in generating units or important transmission lines. At the first stage the system is pushed to its margin stability limit, the critical loads shedding are selected using voltage stability index. In the second stage the generator control variables, the reactive power of shunt and dynamic compensators are adjusted in coordination with minimization the active and reactive power at critical loads to maintain the system at security state to ensure service continuity. The feasibility and efficiency of the proposed strategy is applied to IEEE 30-Bus test system. Results are promising and prove the practical efficiency of the proposed strategy to ensure system security under critical situations

  13. A frequency conversion mode for dispenser in the service station based on flow rate signal

    International Nuclear Information System (INIS)

    Liu, Y J; Tang, D; Huang, J B; Liu, J; Jia, P F

    2012-01-01

    Dispenser is an integrated fuel transport and measurement system at the service station. In this paper, we developed a frequency conversion mode for the dispenser, based on the flow rate signal which is obtained from the converter measuring flow capacity. After introducing the frequency conversion mode to dispenser, we obtained that pump rotates at a high speed when fuelled with high flow rate, and it rotates at a low speed when fuelled with low flow rate. This makes the fuel dispenser more energy-efficient and controllable. We also did some valve optimizations on the dispenser and developed a new control mode for preset refuelling based on the frequency conversion mode, Experimental and theoretical studies have shown that the new dispenser not only can meet the national standards, but also performs better than the ordinary one especially in preset refuelling.

  14. Optimization of measurement methods for a multi-frequency electromagnetic field from mobile phone base station using broadband EMF meter

    Directory of Open Access Journals (Sweden)

    Paweł Bieńkowski

    2015-10-01

    Full Text Available Background: This paper presents the characteristics of the mobile phone base station (BS as an electromagnetic field (EMF source. The most common system configurations with their construction are described. The parameters of radiated EMF in the context of the access to methods and other parameters of the radio transmission are discussed. Attention was also paid to antennas that are used in this technology. Material and Methods: The influence of individual components of a multi-frequency EMF, most commonly found in the BS surroundings, on the resultant EMF strength value indicated by popular broadband EMF meters was analyzed. The examples of metrological characteristics of the most common EMF probes and 2 measurement scenarios of the multisystem base station, with and without microwave relays, are shown. Results: The presented method for measuring the multi-frequency EMF using 2 broadband probes allows for the significant minimization of measurement uncertainty. Equations and formulas that can be used to calculate the actual EMF intensity from multi-frequency sources are shown. They have been verified in the laboratory conditions on a specific standard setup as well as in real conditions in a survey of the existing base station with microwave relays. Conclusions: Presented measurement methodology of multi-frequency EMF from BS with microwave relays, validated both in laboratory and real conditions. It has been proven that the described measurement methodology is the optimal approach to the evaluation of EMF exposure in BS surrounding. Alternative approaches with much greater uncertainty (precaution method or more complex measuring procedure (sources exclusion method are also presented. Med Pr 2015;66(5:701–712

  15. [Optimization of measurement methods for a multi-frequency electromagnetic field from mobile phone base station using broadband EMF meter].

    Science.gov (United States)

    Bieńkowski, Paweł; Cała, Paweł; Zubrzak, Bartłomiej

    2015-01-01

    This paper presents the characteristics of the mobile phone base station (BS) as an electromagnetic field (EMF) source. The most common system configurations with their construction are described. The parameters of radiated EMF in the context of the access to methods and other parameters of the radio transmission are discussed. Attention was also paid to antennas that are used in this technology. The influence of individual components of a multi-frequency EMF, most commonly found in the BS surroundings, on the resultant EMF strength value indicated by popular broadband EMF meters was analyzed. The examples of metrological characteristics of the most common EMF probes and 2 measurement scenarios of the multisystem base station, with and without microwave relays, are shown. The presented method for measuring the multi-frequency EMF using 2 broadband probes allows for the significant minimization of measurement uncertainty. Equations and formulas that can be used to calculate the actual EMF intensity from multi-frequency sources are shown. They have been verified in the laboratory conditions on a specific standard setup as well as in real conditions in a survey of the existing base station with microwave relays. Presented measurement methodology of multi-frequency EMF from BS with microwave relays, validated both in laboratory and real conditions. It has been proven that the described measurement methodology is the optimal approach to the evaluation of EMF exposure in BS surrounding. Alternative approaches with much greater uncertainty (precaution method) or more complex measuring procedure (sources exclusion method) are also presented). This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  16. Cellular computational generalized neuron network for frequency situational intelligence in a multi-machine power system.

    Science.gov (United States)

    Wei, Yawei; Venayagamoorthy, Ganesh Kumar

    2017-09-01

    To prevent large interconnected power system from a cascading failure, brownout or even blackout, grid operators require access to faster than real-time information to make appropriate just-in-time control decisions. However, the communication and computational system limitations of currently used supervisory control and data acquisition (SCADA) system can only deliver delayed information. However, the deployment of synchrophasor measurement devices makes it possible to capture and visualize, in near-real-time, grid operational data with extra granularity. In this paper, a cellular computational network (CCN) approach for frequency situational intelligence (FSI) in a power system is presented. The distributed and scalable computing unit of the CCN framework makes it particularly flexible for customization for a particular set of prediction requirements. Two soft-computing algorithms have been implemented in the CCN framework: a cellular generalized neuron network (CCGNN) and a cellular multi-layer perceptron network (CCMLPN), for purposes of providing multi-timescale frequency predictions, ranging from 16.67 ms to 2 s. These two developed CCGNN and CCMLPN systems were then implemented on two different scales of power systems, one of which installed a large photovoltaic plant. A real-time power system simulator at weather station within the Real-Time Power and Intelligent Systems (RTPIS) laboratory at Clemson, SC, was then used to derive typical FSI results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Radio Frequency Station - Beam Dynamics Interaction in Circular Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Mastoridis, Themistoklis [Stanford Univ., CA (United States)

    2010-08-01

    The longitudinal beam dynamics in circular accelerators is mainly defined by the interaction of the beam current with the accelerating Radio Frequency (RF) stations. For stable operation, Low Level RF (LLRF) feedback systems are employed to reduce coherent instabilities and regulate the accelerating voltage. The LLRF system design has implications for the dynamics and stability of the closed-loop RF systems as well as for the particle beam, and is very sensitive to the operating range of accelerator currents and energies. Stability of the RF loop and the beam are necessary conditions for reliable machine operation. This dissertation describes theoretical formalisms and models that determine the longitudinal beam dynamics based on the LLRF implementation, time domain simulations that capture the dynamic behavior of the RF station-beam interaction, and measurements from the Positron-Electron Project (PEP-II) and the Large Hadron Collider (LHC) that validate the models and simulations. These models and simulations are structured to capture the technical characteristics of the system (noise contributions, non-linear elements, and more). As such, they provide useful results and insight for the development and design of future LLRF feedback systems. They also provide the opportunity to study diverse longitudinal beam dynamics effects such as coupled-bunch impedance driven instabilities and single bunch longitudinal emittance growth. Coupled-bunch instabilities and RF station power were the performance limiting effects for PEP-II. The sensitivity of the instabilities to individual LLRF parameters, the effectiveness of alternative operational algorithms, and the possible tradeoffs between RF loop and beam stability were studied. New algorithms were implemented, with significant performance improvement leading to a world record current during the last PEP-II run of 3212 mA for the Low Energy Ring. Longitudinal beam emittance growth due to RF noise is a major concern for LHC

  18. Selection, design, qualification, testing, and reliability of emergency diesel generator units used as Class 1E onsite electric power systems at nuclear power plants

    International Nuclear Information System (INIS)

    1992-04-01

    This guide has been prepared for the resolution of Generic Safety Issue B-56, ''Diesel Generator Reliability,'' and is related to Unresolved Safety Issue (USI) A-44, ''Station Blackout.'' The resolution of USI A-44 established a need for an emergency diesel generator (EDG) reliability program that has the capability to achieve and maintain the emergency diesel generator reliability levels in the range of 0.95 per demand or better to cope with station blackout

  19. Evaluating the Effect of a Campus-Wide Social Norms Marketing Intervention on Alcohol-Use Perceptions, Consumption, and Blackouts

    Science.gov (United States)

    Su, Jinni; Hancock, Linda; Wattenmaker McGann, Amanda; Alshagra, Mariam; Ericson, Rhianna; Niazi, Zackaria; Dick, Danielle M.; Adkins, Amy

    2018-01-01

    Objective: To evaluate the effect of a campus-wide social norms marketing intervention on alcohol-use perceptions, consumption, and blackouts at a large, urban, public university. Participants: 4,172 college students (1,208 freshmen, 1,159 sophomores, 953 juniors, and 852 seniors) who completed surveys in Spring 2015 for the Spit for Science…

  20. Measurement and Analysis of Radio-frequency Radiation Exposure Level from Different Mobile Base Transceiver Stations in Ajaokuta and Environs, Nigeria

    OpenAIRE

    Ushie, P. O.; Nwankwo, Victor U. J.; Bolaji, Ayinmode; Osahun, O. D.

    2013-01-01

    We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs. The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of other factors, including wave interference from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is below the standard limit (4.5W/sqm for 900MHz and 9W/sq...

  1. Development of Search-Coil Magnetometer for Ultra Low Frequency (ULF) Wave Observations at Jang Bogo Station in Antarctica

    Science.gov (United States)

    Lee, J. K.; Shin, J.; Kim, K. H.; Jin, H.; Kim, H.; Kwon, J.; Lee, S.; Jee, G.; Lessard, M.

    2016-12-01

    A ground-based bi-axial search-coil magnetometer (SCM) has been devloped for observation of time-varying magnetic fields (dB/dt) in the Ultra Low Frequency (ULF) range (a few mHz up to 5 Hz) to understand magnetosphere-ionosphere coupling processes. The SCM consists of magnetic sensors, analog electronics, cables and data acquisition system (DAQ). The bi-axial magnetic sensor has coils of wire wound around a mu-metal cores, each of which measures magnetic field pulsations in the horizontal components, geomagnetic north-south and east-west, respectively. The analog electronics is designed to control the cut-off frequency of the instrument and to amplify detected signals. The DAQ has a 16 bit analog to digital converter (ADC) at the user defined rate of 10 Hz. It is also equipped with the Global Positioning System (GPS) and Network Time Protocol (NTP) for time synchronization and accuracy. We have carried out in-lab performance tests (e.g., frequency response, noise level, etc) using a magnetically shielded case and a field-test in a magnetically quiet location in South Korea. During the field test, a ULF Pi 2 event has been observed clearly. We also confirmed that it was a substorm activity from a fluxgate magnetometer data at Mineyama (35°57.3'N, 135°05'E, geographic). The SCM will be installed and operated at Jang Bogo Antarctic Research Station (74°37.4'S, 164°13.7'E, geographic) on Dec. 2016. The geomagnetic latitude of the station is similar to that of the US McMurdo station (77°51'S, 166°40'E, geographic), both of which are typically near the cusp region. Thus, we expect that the SCM can provide useful information to understand ULF wave propagation characteristics.

  2. The vibrational behaviour of the generator support structure for Koeberg nuclear power station at high frequencies

    International Nuclear Information System (INIS)

    Lee, D.E.

    1988-06-01

    The vibrational behaviour of the generator support structure at Koeberg nuclear power station at frequencies primarily in the region of 80 Hz to 110 Hz was examined. The effect of soil-structure interaction and the change in stiffness of the foundation soil was investigated. Vibration tests were performed on the generator support structure and the results were compared with a theoretical finite element analysis of the structure. By varying the soil-cement foundation stiffness it was possible to demonstrate the change in dynamic behaviour of the structure in the higher frequency band 80 Hz to 110 Hz. Comment has been made on the design code DIN 4024 in view of the findings of this thesis. It was concluded that the empirical rules regarding the inclusion of the foundation in an analysis specified by the code do not cover all cases and greater cognisance of the effect of the foundation stiffness on the vibration behaviour of such machine foundations is necessary. Obvious machine frequencies higher than the operational frequencies should be analysed where it is considered necessary. 24 refs., 25 tabs., 83 figs

  3. RBMK-1500 accident management for loss of long-term core cooling

    International Nuclear Information System (INIS)

    Uspuras, E.; Kaliatka, A.

    2001-01-01

    Results of the Level 1 probabilistic safety assessment of the Ignalina NPP has shown that in topography of the risk, transients dominate above the accidents with LOCAs and failure of the core long-term cooling are the main factors to frequency of the core damage. Previous analyses have shown, that after initial event, as a rule, the reactivity control, as well as short-term and intermediate cooling are provided. However, the acceptance criteria of the long-term cooling are not always carried out. It means that from this point of view the most dangerous accident scenarios are the scenarios related to loss of the core long-term cooling. On the other hand, the transition to the core condition due to loss of the long-term cooling specifies potential opportunities for the management of the accident consequences. Hence, accident management for the mitigation of the accident consequences should be considered and developed. The most likely initiating event, which probably leads to the loss of long term cooling accident, is station blackout. The station blackout is the loss of normal electrical power supply for local needs with an additional failure on start-up of all diesel generators. In the case of loss of electrical power supply MCPs, the circulating pumps of the service water system and MFWPs are switched-off. At the same time, TCV of both turbines are closed. Failure of diesel generators leads to the non-operability of the ECCS long-term cooling subsystem. It means the impossibility to feed MCC by water. The analysis of the station blackout for Ignalina NPP was performed using RELAP5 code. (author)

  4. Retrofit of a liquid pipeline pump station at TRANSPETRO using VFD - Variable Frequency Drive

    Energy Technology Data Exchange (ETDEWEB)

    Santiago, Adilson [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil); Maddarena, Eduardo [Siemens Ltd., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper presents the main operational factors motivating the application of variable frequency drives (VFD) in oil pipeline operations and a real case under way at TRANSPETRO. A brief theoretical introduction on driving centrifugal pumps with variable speed is presented and the available VFD technologies are compared. A practical case using electronic VFD is described concerning a retrofit of a pipeline pump station in the REVAP Refinery in Sao Paulo State. The case encompasses the main aspects considered in the technical and financial feasibility analysis of the retrofit project and describes the operational modes that were changed. (author)

  5. Blackout sequence modeling for Atucha-I with MARCH3 code

    International Nuclear Information System (INIS)

    Baron, J.; Bastianelli, B.

    1997-01-01

    The modeling of a blackout sequence in Atucha I nuclear power plant is presented in this paper, as a preliminary phase for a level II probabilistic safety assessment. Such sequence is analyzed with the code MARCH3 from STCP (Source Term Code Package), based on a specific model developed for Atucha, that takes into accounts it peculiarities. The analysis includes all the severe accident phases, from the initial transient (loss of heat sink), loss of coolant through the safety valves, core uncovered, heatup, metal-water reaction, melting and relocation, heatup and failure of the pressure vessel, core-concrete interaction in the reactor cavity, heatup and failure of the containment building (multi-compartmented) due to quasi-static overpressurization. The results obtained permit to visualize the time sequence of these events, as well as provide the basis for source term studies. (author) [es

  6. Frequency Control Strategy for Black Starts via PMSG-Based Wind Power Generation

    Directory of Open Access Journals (Sweden)

    Yi Tang

    2017-03-01

    Full Text Available The use of wind power generation (WPG as a source for black starts will significantly enhance the resiliency of power systems and shorten their recovery time from blackouts. Given that frequency stability is the most serious issue during the initial recovery period, virtual inertia control can enable wind turbines to provide frequency support to an external system. In this study, a general procedure of WPG participating in black starts is presented, and the key issues are discussed. The adaptability of existing virtual inertia control strategies is analyzed, and improvement work is performed. A new coordinated frequency control strategy is proposed based on the presented improvement work. A local power network with a permanent-magnet synchronous generator (PMSG-based wind farm is modeled and used to verify the effectiveness of the strategy.

  7. Evaluation of Frequency and Restoration time for Loss of Offsite Power events based on domestic operation experience

    International Nuclear Information System (INIS)

    Park, Jin-Hee; Han, Sang-Hoon; Lee, Ho Joong

    2006-01-01

    It is recognized that the availability of AC power to nuclear power plants is essential for safe operation and shutdown and accident recovery of commercial nuclear power plants (NPPs). Unavailability of AC power can be a important adverse impact on a plant's ability to recover accident sequences and maintain safe shutdown. The probabilistic safety assessment (PSA or PRA) performed for Korea NPPs also indicated that a loss of offsite power (LOOP) event and a station blackout (SBO) event can be a important contributors to total risk at nuclear power plant, contributing from 30% to 70% of the total risk at some NPPs in Korea. But, up to now, the LOOP and subsequent restoration time are important inputs to plant probabilistic risk assessment have relied upon foreign data. Therefore, in this paper, the actual LOOP events that have occurred from 1978 to 2004 at commercial nuclear power plants in Korea are collected. A statistical analysis for LOOP frequency and restoration time are performed to apply NPPs's specific and realistic risk model in Korea. Additionally, an engineering analysis is also performed to obtain the insights about the LOOP events

  8. Seismic PRA of a BWR plant

    International Nuclear Information System (INIS)

    Nishio, Masahide; Fujimoto, Haruo

    2014-01-01

    Since the occurrence of nuclear power plant accidents in the Fukushima Daichi nuclear power station, the regulatory framework on severe accident (SA) has been discussed in Japan. The basic concept is to typify and identify the accident sequences leading to core/primary containment vessel (PCV) damage and to implement SA measures covering internal and external events extensively. As Japan is an earthquake-prone country and earthquakes and tsunami are important natural external events for nuclear safety of nuclear power plants, JNES performed the seismic probabilistic risk assessment (PRA) on a typical nuclear power plant and evaluated the dominant accident sequences leading to core/PCV damage to discuss dominant scenarios of severe accident (SA). The analytical models and the results of level-1 seismic PRA on a 1,100 MWe BWR-5 plant are shown here. Seismic PRA was performed for a typical BWR5 plant. Initiating events with large contribution to core damage frequency are the loss of all AC powers (station blackout) and the large LOCA. The top of dominant accident sequences is the simultaneous occurrence of station blackout and large LOCA. Important components to core damage frequency are electric power supply equipment. It needs to keep in mind that the results are influenced on site geologic characteristic to a greater or lesser. In the process of analysis, issues such as conservative assumptions related to damages of building or structure and success criteria for excessive LOCA are left to be resolved. These issues will be further studied including thermal hydric analysis in the future. (authors)

  9. Peak-flow frequency analyses and results based on data through water year 2011 for selected streamflow-gaging stations in or near Montana: Chapter C in Montana StreamStats

    Science.gov (United States)

    Sando, Steven K.; McCarthy, Peter M.; Dutton, DeAnn M.

    2016-04-05

    Chapter C of this Scientific Investigations Report documents results from a study by the U.S. Geological Survey, in cooperation with the Montana Department of Transportation and the Montana Department of Natural Resources, to provide an update of statewide peak-flow frequency analyses and results for Montana. The purpose of this report chapter is to present peak-flow frequency analyses and results for 725 streamflow-gaging stations in or near Montana based on data through water year 2011. The 725 streamflow-gaging stations included in this study represent nearly all streamflowgaging stations in Montana (plus some from adjacent states or Canadian Provinces) that have at least 10 years of peak-flow records through water year 2011. For 29 of the 725 streamflow-gaging stations, peak-flow frequency analyses and results are reported for both unregulated and regulated conditions. Thus, peak-flow frequency analyses and results are reported for a total of 754 analyses. Estimates of peak-flow magnitudes for 66.7-, 50-, 42.9-, 20-, 10-, 4-, 2-, 1-, 0.5-, and 0.2-percent annual exceedance probabilities are reported. These annual exceedance probabilities correspond to 1.5-, 2-, 2.33-, 5-, 10-, 25-, 50-, 100-, 200-, and 500-year recurrence intervals.

  10. Real-time stability in power systems techniques for early detection of the risk of blackout

    CERN Document Server

    Savulescu, Savu

    2014-01-01

    This pioneering volume has been updated and enriched to reflect the state-of-the-art in blackout prediction and prevention. It documents and explains background and algorithmic aspects of the most successful steady-state, transient and voltage stability solutions available today in real-time. It also describes new, cutting-edge stability applications of synchrophasor technology, and captures industry acceptance of metrics and visualization tools that quantify and monitor the distance to instability. Expert contributors review a broad spectrum of additionally available techniques, such as traje

  11. 47 CFR 87.475 - Frequencies.

    Science.gov (United States)

    2010-10-01

    ... with simultaneous radiotelephone channels and their associated glide path station frequency from the...) VHF omni-range (VOR) stations are to be assigned frequencies in the 112.050-117.950 MHz band (50 kHz channel spacing) and the following frequencies in the 108-112 MHz band: 108.200 108.250 108.400 108.450...

  12. A study on the implementation effect of accident management strategies on safety

    International Nuclear Information System (INIS)

    Jae, Moo Sung; Kim, Dong Ha; Jin, Young Ho

    1996-01-01

    This paper presents a new approach for assessing accident management strategies using containment event trees(CETs) developed during an individual plant examination (IPE) for a reference plant (CE type, 950 MWe PWR). Various accident management strategies to reduce risk have been proposed through IPE. Three strategies for the station blackout sequence are used as an example: 1) reactor cavity flooding only, 2) primary system depressurization only, and 3) doing both. These strategies are assumed to be initiated at about the time of core uncovery. The station blackout (SBO) sequence is selected in this paper since it is identified as one of the most threatening sequences to safety of the reference plant. The effectiveness and adverse effects of each accident management strategy are considered synthetically in the CETs. A best estimate assessment for the developed CETs using data obtained from NUREG-1150, other PRA results, and the MAAP code calculations is performed. The strategies are ranked with respect to minimizing the frequencies of various containment failure modes. The proposed approach is demonstrated to be very flexible in that it can be applied to any kind of accident management strategy for any sequence. 9 refs., 3 figs., 2 tabs. (author)

  13. Mobile phone base stations and adverse health effects: phase 2 of a cross-sectional study with measured radio frequency electromagnetic fields

    DEFF Research Database (Denmark)

    Berg-Beckhoff, Gabriele; Blettner, M; Kowall, B

    2009-01-01

    OBJECTIVE: The aim of the cross-sectional study was to test the hypothesis that exposure to continuous low-level radio frequency electromagnetic fields (RF-EMFs) emitted from mobile phone base stations was related to various health disturbances. METHODS: For the investigation people living mainly...

  14. Resolution of GSI B-56 - Emergency diesel generator reliability

    International Nuclear Information System (INIS)

    Serkiz, A.W.

    1989-01-01

    The need for an emergency diesel generator (EDG) reliability program has been established by 10 CFR Part 50, Section 50.63, Loss of All Alternating Current Power, which requires that licensees assess their station blackout coping and recovery capability. EDGs are the principal emergency ac power sources for avoiding a station blackout. Regulatory Guide 1.155, Station Blackout, identifies a need for (1) a nuclear unit EDG reliability level of at least 0.95, and (2) an EDG reliability program to monitor and maintain the required EDG reliability levels. NUMARC-8700, Guidelines and Technical Bases for NUMARC Initiatives Addressing Station Blackout at Light Water Reactors, also provides guidance on such needs. The resolution of GSI B-56, Diesel Reliability will be accomplished by issuing Regulatory Guide 1.9, Rev. 3, Selection, Design, Qualification, Testing, and Reliability of Diesel Generator Units Used as Onsite Electric Power Systems at Nuclear Plants. This revision will integrate into a single regulatory guide pertinent guidance previously addressed in R.G. 1.9, Rev. 2, R.G. 1.108, and Generic Letter 84-15. R.G. 1.9 has been expanded to define the principal elements of an EDG reliability program for monitoring and maintaining EDG reliability levels selected for SBO. In addition, alert levels and corrective actions have been defined to detect a deteriorating situation for all EDGs assigned to a particular nuclear unit, as well as an individual problem EDG

  15. 47 CFR 80.655 - Use of frequencies.

    Science.gov (United States)

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Maritime Support Stations § 80.655 Use of frequencies. (a) The frequencies available for assignment to maritime support stations are described or listed in: (1) Section 80.373 for scope of...

  16. Single-frequency receivers as master permanent stations in GNSS networks: precision and accuracy of the positioning in mixed networks

    Science.gov (United States)

    Dabove, Paolo; Manzino, Ambrogio Maria

    2015-04-01

    The use of GPS/GNSS instruments is a common practice in the world at both a commercial and academic research level. Since last ten years, Continuous Operating Reference Stations (CORSs) networks were born in order to achieve the possibility to extend a precise positioning more than 15 km far from the master station. In this context, the Geomatics Research Group of DIATI at the Politecnico di Torino has carried out several experiments in order to evaluate the achievable precision obtainable with different GNSS receivers (geodetic and mass-market) and antennas if a CORSs network is considered. This work starts from the research above described, in particular focusing the attention on the usefulness of single frequency permanent stations in order to thicken the existing CORSs, especially for monitoring purposes. Two different types of CORSs network are available today in Italy: the first one is the so called "regional network" and the second one is the "national network", where the mean inter-station distances are about 25/30 and 50/70 km respectively. These distances are useful for many applications (e.g. mobile mapping) if geodetic instruments are considered but become less useful if mass-market instruments are used or if the inter-station distance between master and rover increases. In this context, some innovative GNSS networks were developed and tested, analyzing the performance of rover's positioning in terms of quality, accuracy and reliability both in real-time and post-processing approach. The use of single frequency GNSS receivers leads to have some limits, especially due to a limited baseline length, the possibility to obtain a correct fixing of the phase ambiguity for the network and to fix the phase ambiguity correctly also for the rover. These factors play a crucial role in order to reach a positioning with a good level of accuracy (as centimetric o better) in a short time and with an high reliability. The goal of this work is to investigate about the

  17. A novel static frequency converter based on multilevel cascaded H-bridge used for the startup of synchronous motor in pumped-storage power station

    Energy Technology Data Exchange (ETDEWEB)

    Wang Feng, E-mail: sjtuwfeng@hotmail.co [Key Lab of Control of Power Transmission and Transformation, Ministry of Education, Department of Electrical Engineering, Shanghai Jiaotong University, Minhang District, Shanghai 200240 (China); Jiang Jianguo, E-mail: jiang@sjtu.edu.c [Key Lab of Control of Power Transmission and Transformation, Ministry of Education, Department of Electrical Engineering, Shanghai Jiaotong University, Minhang District, Shanghai 200240 (China)

    2011-05-15

    Research highlights: {yields} A novel Static Frequency Converter (SFC) based on multilevel cascaded H-bridge (CHB) topology is proposed and used for the reversible pump-generating units in pumped-storage power station. {yields} The novel SFC based on CHB has compact configuration, low current harmonic distortion and fast speed response. {yields} Rotor position and Grid connection are realized successfully by the novel SFC. -- Abstract: A novel static frequency converter (SFC) is proposed and is used firstly to start the reversible pump-generating units in pumped-storage power station. Multilevel cascaded H-bridge (CHB) topology and Insulated Gate Bipolar Transistor (IGBT) are applied in the novel SFC. In comparison with the conventional SFC adopting load-commutated inverter (LCI) which is composed of silicon-controlled rectifier (SCR), the novel one has plenty of advantages such as compact configuration, low current harmonic distortion and fast speed response, and these advantages have been verified during 2-year operation at Xiang Hong Dian Pumped-storage power station in China. This application shows that the novel SFC greatly enhances the reliability and success rate of connecting to grid for starting up the pump-generating units. The principle, characteristic and performance of the novel SFC are described in this paper, and some key issues related to the startup of the units of the pumped-storage power station are also presented.

  18. The Threshold of the State: Civil Defence, the Blackout and the Home in Second World War Britain.

    Science.gov (United States)

    Greenhalgh, James

    2017-06-01

    This article reconsiders the way that the British state extended its control of the home during the Second World War, using the implementation of air raid precautions and the blackout as a lens through which to view the state's developing attitudes to domestic space. Presented here is not the familiar story of pitch-dark, dangerous streets or altered cityscapes of fear and destruction; instead, by examining personal testimony the article inverts traditional treatments of the blackout to look at the interior of dwellings, demonstrating how the realities of total warfare impinged upon the psychological elements that constituted the home. What emerges not only expands historical understandings of the wartime experience of civilians, it also shows civil defence measures as highly visible points on an often antagonistic trajectory of state interactions with citizens concerning the privacy and security of the dwelling in the modern city. The requirements of civil defence, I argue, were not merely the product of exceptional wartime circumstances, but symptomatic of long-standing attempts to open up dwellings to state scrutiny. These attempts had both a significant pre-war lineage and, crucially, implications beyond the end of the war in private homes and on social housing estates. © The Author [2017]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Sources of high frequency seismic noise: insights from a dense network of ~250 stations in northern Alsace (France)

    Science.gov (United States)

    Vergne, Jerome; Blachet, Antoine; Lehujeur, Maximilien

    2015-04-01

    Monitoring local or regional seismic activity requires stations having a low level of background seismic noise at frequencies higher than few tenths of Hertz. Network operators are well aware that the seismic quality of a site depends on several aspects, among them its geological setting and the proximity of roads, railways, industries or trees. Often, the impact of each noise source is only qualitatively known which precludes estimating the quality of potential future sites before they are tested or installed. Here, we want to take advantage of a very dense temporary network deployed in Northern Alsace (France) to assess the effect of various kinds of potential sources on the level of seismic noise observed in the frequency range 0.2-50 Hz. In September 2014, more than 250 seismic stations (FairfieldNodal@ Zland nodes with 10Hz vertical geophone) have been installed every 1.5 km over a ~25km diameter disc centred on the deep geothermal sites of Soultz-sous-Forêts and Rittershoffen. This region exhibits variable degrees of human imprints from quite remote areas to sectors with high traffic roads and big villages. It also encompasses both the deep sedimentary basin of the Rhine graben and the piedmont of the Vosges massif with exposed bedrock. For each site we processed the continuous data to estimate probability density functions of the power spectral densities. At frequencies higher than 1 Hz most sites show a clear temporal modulation of seismic noise related to human activity with the well-known variations between day and night and between weekdays and weekends. Moreover we observe a clear evolution of the spatial distribution of seismic noise levels with frequency. Basically, between 0.5 and 4 Hz the geological setting modulates the level of seismic noise. At higher frequencies, the amplitude of seismic noise appears mostly related to the distance to nearby roads. Based on road maps and traffic estimation, a forward approach is performed to model the induced

  20. Propagation of low frequency geomagnetic field fluctuations in Antarctica: comparison between two polar cap stations

    Directory of Open Access Journals (Sweden)

    L. Santarelli

    2007-11-01

    Full Text Available We conduct a statistical analysis of the coherence and phase difference of low frequency geomagnetic fluctuations between two Antarctic stations, Mario Zucchelli Station (geographic coordinates: 74.7° S, 164.1° E; corrected geomagnetic coordinates: 80.0° S, 307.7° E and Scott Base (geographic coordinates: 77.8° S 166.8° E; corrected geomagnetic coordinates: 80.0° S 326.5° E, both located in the polar cap. Due to the relative position of the stations, whose displacement is essentially along a geomagnetic parallel, the phase difference analysis allows to determine the direction of azimuthal propagation of geomagnetic fluctuations. The results show that coherent fluctuations are essentially detectable around local geomagnetic midnight and, in a minor extent, around noon; moreover, the phase difference reverses in the night time hours, indicating a propagation direction away from midnight, and also around local geomagnetic noon, indicating a propagation direction away from the subsolar point. The nigh time phase reversal is more clear for southward interplanetary magnetic field conditions, suggesting a relation with substorm activity. The introduction, in this analysis, of the Interplanetary Magnetic Field conditions, gave interesting results, indicating a relation with substorm activity during nighttime hours. We also conducted a study of three individual pulsation events in order to find a correspondence with the statistical behaviour. In particular, a peculiar event, characterized by quiet magnetospheric and northward interplanetary magnetic field conditions, shows a clear example of waves propagating away from the local geomagnetic noon; two more events, occurring during southward interplanetary magnetic field conditions, in one case even during a moderate storm, show waves propagating away from the local geomagnetic midnight.

  1. Enhancing the accuracy of GPS point positioning by converting the single frequency data to dual frequency data

    Directory of Open Access Journals (Sweden)

    Aly M. El-naggar

    2011-09-01

    Full Text Available The global positioning system (GPS has been used to support a wide variety of applications, such as high-accuracy positioning and navigation. Differential GPS techniques can largely eliminate common-mode errors between the reference and the rover GPS stations resulting from ionospheric and tropospheric refraction and delays, satellite and receiver clock biases, and orbital errors [1]. The ionospheric delay in the propagation of global positioning system (GPS signals is one of the main sources of error in GPS precise positioning and navigation. A dual-frequency GPS receiver can eliminate (to the first order the ionospheric delay through a linear combination of the L1 and L2 observations [2]. The most significant effect of ionospheric delay appear in case of using single frequency data. In this paper the single frequency data of concerned station are converted to dual frequency data by employing dual frequency data from 11 regional GPS stations distributed around it. Total electron content (TEC was calculated at every GPS station to produce the mathematical model of TEC which is a function of latitude (Φ and longitude (λ. By using this mathematical model the values of TEC and L2 can be predicted at the single frequency GPS station for each satellite, after that the comparison between predicted and observation values of TEC and L2 was performed. The estimation method and test results of the proposed method indicates that the difference between predicted and observation values is very small.

  2. Review of the Shoreham Nuclear Power Station Probabilistic Risk Assessment: internal events and core damage frequency

    International Nuclear Information System (INIS)

    Ilberg, D.; Shiu, K.; Hanan, N.; Anavim, E.

    1985-11-01

    A review of the Probabilistic Risk Assessment of the Shoreham Nuclear Power Station was conducted with the broad objective of evaluating its risks in relation to those identified in the Reactor Safety Study (WASH-1400). The scope of the review was limited to the ''front end'' part, i.e., to the evaluation of the frequencies of states in which core damage may occur. Furthermore, the review considered only internally generated accidents, consistent with the scope of the PRA. The review included an assessment of the assumptions and methods used in the Shoreham study. It also encompassed a reevaluation of the main results within the scope and general methodological framework of the Shoreham PRA, including both qualitative and quantitative analyses of accident initiators, data bases, and accident sequences which result in initiation of core damage. Specific comparisons are given between the Shoreham study, the results of the present review, and the WASH-1400 BWR, for the core damage frequency. The effect of modeling uncertainties was considered by a limited sensitivity study so as to show how the results would change if other assumptions were made. This review provides an independently assessed point value estimate of core damage frequency and describes the major contributors, by frontline systems and by accident sequences. 17 figs., 81 tabs

  3. Analysis of data flow and activities at radiology reporting stations for design and evaluation of digital work stations

    International Nuclear Information System (INIS)

    Mun, S.K.; Benson, H.; Welsh, C.; Elliott, L.P.; Zeman, R.

    1987-01-01

    Definition of necessary and desirable functional capabilities of PACS work stations is critical in the design of digital systems for the successful clinical acceptance of digital imaging networks. The authors conducted a detailed time motion study of data flow pattern, diagnostic decision making, and reporting activities at current film alternators for neuroradiology, body CT, and pulmonary service. The measured parameters include data volume, data presentation speed, frequency of use of previous studies, efforts needed to retrieve previous studies, time required for diagnosis, frequency and duration of consultation with referring physicians, frequency of interruptions, and dictation time an defficiency. The result of this study provides critical information in designing digital work stations for various services

  4. 47 CFR 97.207 - Space station.

    Science.gov (United States)

    2010-10-01

    ... FCC. (c) The following frequency bands and segments are authorized to space stations: (1) The 17 m, 15... notifications to the International Bureau, FCC, Washington, DC 20554. (1) A pre-space notification within 30... risk of collision and a description of what measures the space station operator plans to take to avoid...

  5. Accelerating Rf Station For Hirfl-csr, Lanzhou, China

    CERN Document Server

    Arbuzov, V S; Dranichnikov, A N; Gorniker, E I; Kondakov, A A; Kondaurov, M; Kruchkov, Ya G; Krutikhin, S A; Kurkin, G Ya; Mironenko, L A; Motygin, S V; Osipov, V N; Petrov, V M; Pilan, Andrey M; Popov, A M; Sedlyarov, I K; Selivanov, A N; Shteinke, A R; Vajenin, N F

    2004-01-01

    In accordance with the plan of cooperation with the Institute of Modern Physics (IMP), Lanzhou, China, the Budker Institute of Nuclear Physics (BINP), Novosibirsk, Russia has produced and supplied an accelerating RF station for the multipurpose Cooling Storage Ring system (CSR), which is being constructed at IMP. The RF station had been tested at IMP site and now is installed into the Main Ring of the facilities. The RF station operates in the frequency range of 0.25~1.7 MHz. Maximum accelerating voltage is 8 kV. The resonance frequency of the RF cavity is tuned in the whole frequency range by biasing of ferrites, which are used in the cavity. Ferrites of 600NN type were produced by a firm manufacture "Magneton", St. Petersburg. The pressure in the cavity vacuum chamber is lower, than 3·10-11

  6. Propagation of low frequency geomagnetic field fluctuations in Antarctica: comparison between two polar cap stations

    Directory of Open Access Journals (Sweden)

    L. Santarelli

    2007-11-01

    Full Text Available We conduct a statistical analysis of the coherence and phase difference of low frequency geomagnetic fluctuations between two Antarctic stations, Mario Zucchelli Station (geographic coordinates: 74.7° S, 164.1° E; corrected geomagnetic coordinates: 80.0° S, 307.7° E and Scott Base (geographic coordinates: 77.8° S 166.8° E; corrected geomagnetic coordinates: 80.0° S 326.5° E, both located in the polar cap. Due to the relative position of the stations, whose displacement is essentially along a geomagnetic parallel, the phase difference analysis allows to determine the direction of azimuthal propagation of geomagnetic fluctuations. The results show that coherent fluctuations are essentially detectable around local geomagnetic midnight and, in a minor extent, around noon; moreover, the phase difference reverses in the night time hours, indicating a propagation direction away from midnight, and also around local geomagnetic noon, indicating a propagation direction away from the subsolar point. The nigh time phase reversal is more clear for southward interplanetary magnetic field conditions, suggesting a relation with substorm activity.

    The introduction, in this analysis, of the Interplanetary Magnetic Field conditions, gave interesting results, indicating a relation with substorm activity during nighttime hours.

    We also conducted a study of three individual pulsation events in order to find a correspondence with the statistical behaviour. In particular, a peculiar event, characterized by quiet magnetospheric and northward interplanetary magnetic field conditions, shows a clear example of waves propagating away from the local geomagnetic noon; two more events, occurring during southward interplanetary magnetic field conditions, in one case even during a moderate storm, show waves propagating away from the local geomagnetic midnight.

  7. Alternative off-site power supply improves nuclear power plant safety

    International Nuclear Information System (INIS)

    Gjorgiev, Blaže; Volkanovski, Andrija; Kančev, Duško; Čepin, Marko

    2014-01-01

    Highlights: • Additional power supply for mitigation of the station blackout event in NPP is used. • A hydro power plant is considered as an off-site alternative power supply. • An upgrade of the probabilistic safety assessment from its traditional use is made. • The obtained results show improvement of nuclear power plant safety. - Abstract: A reliable power system is important for safe operation of the nuclear power plants. The station blackout event is of great importance for nuclear power plant safety. This event is caused by the loss of all alternating current power supply to the safety and non-safety buses of the nuclear power plant. In this study an independent electrical connection between a pumped-storage hydro power plant and a nuclear power plant is assumed as a standpoint for safety and reliability analysis. The pumped-storage hydro power plant is considered as an alternative power supply. The connection with conventional accumulation type of hydro power plant is analysed in addition. The objective of this paper is to investigate the improvement of nuclear power plant safety resulting from the consideration of the alternative power supplies. The safety of the nuclear power plant is analysed through the core damage frequency, a risk measure assess by the probabilistic safety assessment. The presented method upgrades the probabilistic safety assessment from its common traditional use in sense that it considers non-plant sited systems. The obtained results show significant decrease of the core damage frequency, indicating improvement of nuclear safety if hydro power plant is introduced as an alternative off-site power source

  8. Comparison of Severe Accident Results Among SCDAP/RELAP5, MAAP, and MELCOR Codes

    International Nuclear Information System (INIS)

    Wang, T.-C.; Wang, S.-J.; Teng, J.-T.

    2005-01-01

    This paper demonstrates a large-break loss-of-coolant accident (LOCA) sequence of the Kuosheng nuclear power plant (NPP) and station blackout sequence of the Maanshan NPP with the SCDAP/RELAP5 (SR5), Modular Accident Analysis Program (MAAP), and MELCOR codes. The large-break sequence initiated with double-ended rupture of a recirculation loop. The main steam isolation valves (MSIVs) closed, the feedwater pump tripped, the reactor scrammed, and the assumed high-pressure and low-pressure spray systems of the emergency core cooling system (ECCS) were not functional. Therefore, all coolant systems to quench the core were lost. MAAP predicts a longer vessel failure time, and MELCOR predicts a shorter vessel failure time for the large-break LOCA sequence. The station blackout sequence initiated with a loss of all alternating-current (ac) power. The MSIVs closed, the feedwater pump tripped, and the reactor scrammed. The motor-driven auxiliary feedwater system and the high-pressure and low-pressure injection systems of the ECCS were lost because of the loss of all ac power. It was also assumed that the turbine-driven auxiliary feedwater pump was not functional. Therefore, the coolant system to quench the core was also lost. MAAP predicts a longer time of steam generator dryout, time interval between top of active fuel and bottom of active fuel, and vessel failure time than those of the SR5 and MELCOR predictions for the station blackout sequence. The three codes give similar results for important phenomena during the accidents, including SG dryout, core uncovery, cladding oxidation, cladding failure, molten pool formulation, debris relocation to the lower plenum, and vessel head failure. This paper successfully demonstrates the large-break LOCA sequence of the Kuosheng NPP and the station blackout sequence of the Maanshan NPP

  9. Out of the Blackout and into the Light: How the Arts Survived Pinochet’s Dictatorship

    Directory of Open Access Journals (Sweden)

    Paula Thorrington Cronovich

    2014-06-01

    This article shows how various artists segued out of the cultural blackout of the late seventies and into a phase of surprising artistic production during the military regime in Chile. At a time when political parties were banned and public gatherings considered illegal, Chileans found alternative ways to oppose the military government. In this climate, I argue that artistic expression took on political meaning. The fact that the “No” Campaign of 1988 was able to oust the dictator with an optimistic message of joy and hope, attests to the point that Chileans were able to shed their fears and change their outlook. Throughout the decade, the arts—innovations in poetry, music, theater, narrative and the audiovisual media—had offered people a much-needed forum for expression.

  10. 47 CFR 80.373 - Private communications frequencies.

    Science.gov (United States)

    2010-10-01

    ... band for medical advisory communications. (1) Private coast stations may be authorized to use any... stations of radiotelephony frequencies in the 2000-27500 kHz band are subject to the following: (1) Private... stations serving lakes or rivers are not authorized on the 2000-2850 kHz band. (4) Private coast stations...

  11. Alternative cooling water flow path for RHR heat exchanger and its effect on containment response during extended station blackout for Chinshan BWR-4 plant

    Energy Technology Data Exchange (ETDEWEB)

    Yuann, Yng-Ruey, E-mail: ryyuann@iner.gov.tw

    2016-04-15

    Highlights: • Motivating alternative RHR heat exchanger tube-side flow path and determining required capacity. • Calculate NSSS and containment response during 24-h SBO for Chinshan BWR-4 plant. • RETRAN and GOTHIC models are developed for NSSS and containment, respectively. • Safety relief valve blowdown flow and energy to drywell are generated by RETRAN. • Analyses are performed with and without reactor depressurization, respectively. - Abstract: The extended Station Blackout (SBO) of 24 h has been analyzed with respect to the containment response, in particular the suppression pool temperature response, for the Chinshan BWR-4 plant of MARK-I containment. The Chinshan plant, owned by Taiwan Power Company, has twin units with rated core thermal power of 1840 MW each. The analysis is aimed at determining the required alternative cooling water flow capacity for the residual heat removal (RHR) heat exchanger when its tube-side sea water cooling flow path is blocked, due to some reason such as earthquake or tsunami, and is switched to the alternative raw water source. Energy will be dissipated to the suppression pool through safety relief valves (SRVs) of the main steam lines during SBO. The RETRAN model is used to calculate the Nuclear Steam Supply System (NSSS) response and generate the SRV blowdown conditions, including SRV pressure, enthalpy, and mass flow rate. These conditions are then used as the time-dependent boundary conditions for the GOTHIC code to calculate the containment pressure and temperature response. The shaft seals of the two recirculation pumps are conservatively assumed to fail due to loss of seal cooling and a total leakage flow rate of 36 gpm to the drywell is included in the GOTHIC model. Based on the given SRV blowdown conditions, the GOTHIC containment calculation is performed several times, through the adjustment of the heat transfer rate of the RHR heat exchanger, until the criterion that the maximum suppression pool temperature

  12. The influence of subway station design on noise levels.

    Science.gov (United States)

    Shah, Ravi R; Suen, Jonathan J; Cellum, Ilana P; Spitzer, Jaclyn B; Lalwani, Anil K

    2017-05-01

    To investigate the impact of subway station design on platform noise levels. Observational. Continuous A-weighted decibel (dBA) sound levels were recorded in 20 New York City subway stations, where trains entered on either a straight track or curved track in 10 stations each. Equivalent continuous noise levels (L eq ) at various locations on the boarding platform (inbound end, midplatform, and outbound end) during train entry and exit were compared between the straight and curved stations in broadband as well as narrow one-third octave bands. Overall, curved stations trended louder than straight stations, although the difference in broadband L eq did not reach statistical significance (curve, 83.4 dBA; straight, 82.6 dBA; P = .054). Noise levels were significantly louder at the inbound end of the platform during train entry (inbound, 89.7 dBA; mid, 85.5 dBA; outbound, 78.7 dBA; P < .001) and at the outbound end during train exit (inbound, 79.7 dBA; mid, 85.3 dBA; outbound, 89.1 dBA; P < .001). Narrow band analysis showed that curved stations were significantly louder than straight stations at 100 Hz and high frequencies from 8 to 20 kHz. Peak impact levels ranged from 104 to 121 dBA. Curved stations have a different noise profile compared to straight stations and are significantly louder than straight stations at high frequencies. Designing stations with straight tracks within the platform can help reduce commuter noise exposure. NA Laryngoscope, 127:1169-1174, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  13. A comparison of Frequency Domain Multiple Access (FDMA) and Time Domain Multiple Access (TDMA) approaches to satellite service for low data rate Earth stations

    Science.gov (United States)

    Stevens, G.

    1983-01-01

    A technological and economic assessment is made of providing low data rate service to small earth stations by satellite at Ka-band. Various Frequency Domain Multiple Access (FDMA) and Time Domain Multiple Access (TDMA) scenarios are examined and compared on the basis of cost to the end user. Very small stations (1 to 2 meters in diameter) are found not to be viable alternatives to available terrestrial services. However, medium size (3 to 5 meters) earth stations appear to be very competitive if a minimum throughput of about 1.5 Mbs is maintained. This constrains the use of such terminals to large users and shared use by smaller users. No advantage was found to the use of FDMA. TDMA had a slight advantage from a total system viewpoint and a very significant advantage in the space segment (about 1/3 the required payload weight for an equivalent capacity).

  14. Contributions of the restructuring of the electric power industry to the August 14, 2003 blackout

    International Nuclear Information System (INIS)

    Casazza, J.; Delea, F.; Loehr, G.

    2005-01-01

    A review of the roles of industry and government in the 2003 blackout was presented. This white paper was prepared by a group of engineers with high level experience in the electric power industry who are concerned that deregulation of the industry has led to a significant decrease in reliability. It was noted that post-blackout reviews have focused on technical failures instead of examining the responsibilities and failures of the National Electric Reliability Council (NERC). Deficiencies in the analytical capabilities of control centres were discussed, as well as issues concerning communication protocols and training. Deregulation and the concomitant restructuring of the electric power industry has led to a shift from long term optimization, inter-system coordination and reliability towards dependence on immediate profits. In addition, there have been significant reductions in personnel at electric power organizations and companies, as well as increasing complexity in operations. Increased complexity has resulted in a dilution of management responsibility, as well as over-reliance on markets to solve scientifically complex problems. There have also been cutbacks in training and research. The functional separation of generation and transmission within companies has contributed to the diffusion of best technical knowledge. Many private utilities have divested their generation resources in response to regulatory pressures. The entrance of merchant power plants in the power system has led to the establishment of new market areas that are inconsistent with the boundaries of responsible operating entities. It was concluded that all these changes have created a more complicated and compartmentalized industry structure. Decisions are now made by a large number of entities, most of which are competitors and each of which has more interest in profit than in bulk power system reliability. Procedural rules established between and among the various parties are no longer

  15. Evaluation of the expected moments algorithm and a multiple low-outlier test for flood frequency analysis at streamgaging stations in Arizona

    Science.gov (United States)

    Paretti, Nicholas V.; Kennedy, Jeffrey R.; Cohn, Timothy A.

    2014-01-01

    Flooding is among the costliest natural disasters in terms of loss of life and property in Arizona, which is why the accurate estimation of flood frequency and magnitude is crucial for proper structural design and accurate floodplain mapping. Current guidelines for flood frequency analysis in the United States are described in Bulletin 17B (B17B), yet since B17B’s publication in 1982 (Interagency Advisory Committee on Water Data, 1982), several improvements have been proposed as updates for future guidelines. Two proposed updates are the Expected Moments Algorithm (EMA) to accommodate historical and censored data, and a generalized multiple Grubbs-Beck (MGB) low-outlier test. The current guidelines use a standard Grubbs-Beck (GB) method to identify low outliers, changing the determination of the moment estimators because B17B uses a conditional probability adjustment to handle low outliers while EMA censors the low outliers. B17B and EMA estimates are identical if no historical information or censored or low outliers are present in the peak-flow data. EMA with MGB (EMA-MGB) test was compared to the standard B17B (B17B-GB) method for flood frequency analysis at 328 streamgaging stations in Arizona. The methods were compared using the relative percent difference (RPD) between annual exceedance probabilities (AEPs), goodness-of-fit assessments, random resampling procedures, and Monte Carlo simulations. The AEPs were calculated and compared using both station skew and weighted skew. Streamgaging stations were classified by U.S. Geological Survey (USGS) National Water Information System (NWIS) qualification codes, used to denote historical and censored peak-flow data, to better understand the effect that nonstandard flood information has on the flood frequency analysis for each method. Streamgaging stations were also grouped according to geographic flood regions and analyzed separately to better understand regional differences caused by physiography and climate. The B

  16. Wind Generation Participation in Power System Frequency Response: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gevorgian, Vahan; Zhang, Yingchen

    2017-01-01

    The electrical frequency of an interconnected power system must be maintained close its nominal level at all times. Excessive under- and overfrequency excursions can lead to load shedding, instability, machine damage, and even blackouts. There is a rising concern in the electric power industry in recent years about the declining amount of inertia and primary frequency response (PFR) in many interconnections. This decline may continue due to increasing penetrations of inverter-coupled generation and the planned retirements of conventional thermal plants. Inverter-coupled variable wind generation is capable of contributing to PFR and inertia with a response that is different from that of conventional generation. It is not yet entirely understood how such a response will affect the system at different wind power penetration levels. The modeling work presented in this paper evaluates the impact of wind generation's provision of these active power control strategies on a large, synchronous interconnection. All simulations were conducted on the U.S. Western Interconnection with different levels of instantaneous wind power penetrations (up to 80%). The ability of wind power plants to provide PFR - and a combination of synthetic inertial response and PFR - significantly improved the frequency response performance of the system.

  17. 47 CFR 80.223 - Special requirements for survival craft stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Special requirements for survival craft... requirements for survival craft stations. (a) Survival craft stations capable of transmitting on: (1) 2182 kHz... operate with A3E or A3N emission. (b) Survival craft stations must be able to receive the frequency and...

  18. Space Shuttle and Space Station Radio Frequency (RF) Exposure Analysis

    Science.gov (United States)

    Hwu, Shian U.; Loh, Yin-Chung; Sham, Catherine C.; Kroll, Quin D.

    2005-01-01

    This paper outlines the modeling techniques and important parameters to define a rigorous but practical procedure that can verify the compliance of RF exposure to the NASA standards for astronauts and electronic equipment. The electromagnetic modeling techniques are applied to analyze RF exposure in Space Shuttle and Space Station environments with reasonable computing time and resources. The modeling techniques are capable of taking into account the field interactions with Space Shuttle and Space Station structures. The obtained results illustrate the multipath effects due to the presence of the space vehicle structures. It's necessary to include the field interactions with the space vehicle in the analysis for an accurate assessment of the RF exposure. Based on the obtained results, the RF keep out zones are identified for appropriate operational scenarios, flight rules and necessary RF transmitter constraints to ensure a safe operating environment and mission success.

  19. Utilization of Relap 5 computer code for analyzing thermohydraulic projects

    International Nuclear Information System (INIS)

    Silva Filho, E.

    1987-01-01

    This work deals with the design of a scaled test facility of a typical pressurized water reactor plant of the 1300 MW (electric) class. A station blackout has been choosen to investigate the thermohydraulic behaviour of the the test facility in comparison to the reactor plant. The computer code RELAPS/MOD1 has been utilized to simulate the blackout and to compare the test facility behaviour with the reactor plant one. The results demonstrate similar thermohydraulic behaviours of the two systems. (author) [pt

  20. Electrical Grid Stability Enhancement using Smart Home Frequency-response Grid -Friendly Appliance System

    Directory of Open Access Journals (Sweden)

    Muawiya A. Kaigama

    2016-03-01

    Full Text Available Load shedding is a powerful scheme used for corrective and preventive measures; corrective to restore system’s stability and preventive to avoid catastrophic failure. However, the affected end users are deprived of power supply absolutely with no choice. This paper presents the design, development, feasibility and merits of Frequency-response Grid -Friendly Appliance System (FRGFAS in a smart home. FRGFAS is a decentralized Adaptive Load Shaving(ALS device that supports grid’s system stability by sensing grid’s frequency deterioration level and turns ON/OFF loads accordingly. The FRGFAS permits end users to carry out load shaving at their scale of preference in smart homes via flexible demand responses and automates outdoor lighting to optimum operational hours. FRGFAS obviate load shedding by shaving loads whenever the system is in distress and reset loads supply to the normal state when it stabilizes, this Consequently increases the end user comfort zone and averts a blackout.

  1. 47 CFR 80.1123 - Watch requirements for ship stations.

    Science.gov (United States)

    2010-10-01

    ... Section 80.1123 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating... watches for broadcasts of maritime safety information on the appropriate frequency or frequencies on which...

  2. 47 CFR 76.128 - Application of sports blackout rules.

    Science.gov (United States)

    2010-10-01

    ... stations within whose specified zone the community of the community unit or the community within which the... other than major markets as defined in § 76.51, television broadcast stations within whose Grade B... specified zone. [65 FR 68101, Nov. 14, 2000, as amended at 67 FR 68951, Nov. 14, 2002] ...

  3. Magnetic field measurements near stand-alone transformer stations.

    Science.gov (United States)

    Kandel, Shaiela; Hareuveny, Ronen; Yitzhak, Nir-Mordechay; Ruppin, Raphael

    2013-12-01

    Extremely low-frequency (ELF) magnetic field (MF) measurements around and above three stand-alone 22/0.4-kV transformer stations have been performed. The low-voltage (LV) cables between the transformer and the LV switchgear were found to be the major source of strong ELF MFs of limited spatial extent. The strong fields measured above the transformer stations support the assessment method, to be used in future epidemiological studies, of classifying apartments located right above the transformer stations as highly exposed to MFs. The results of the MF measurements above the ground around the transformer stations provide a basis for the assessment of the option of implementing precautionary procedures.

  4. Solar observations with a low frequency radio telescope

    Science.gov (United States)

    Myserlis, I.; Seiradakis, J.; Dogramatzidis, M.

    2012-01-01

    We have set up a low frequency radio monitoring station for solar bursts at the Observatory of the Aristotle University in Thessaloniki. The station consists of a dual dipole phased array, a radio receiver and a dedicated computer with the necessary software installed. The constructed radio receiver is based on NASA's Radio Jove project. It operates continuously, since July 2010, at 20.1 MHz (close to the long-wavelength ionospheric cut-off of the radio window) with a narrow bandwidth (~5 kHz). The system is properly calibrated, so that the recorded data are expressed in antenna temperature. Despite the high interference level of an urban region like Thessaloniki (strong broadcasting shortwave radio stations, periodic experimental signals, CBs, etc), we have detected several low frequency solar radio bursts and correlated them with solar flares, X-ray events and other low frequency solar observations. The received signal is monitored in ordinary ASCII format and as audio signal, in order to investigate and exclude man-made radio interference. In order to exclude narrow band interference and calculate the spectral indices of the observed events, a second monitoring station, working at 36 MHz, is under construction at the village of Nikiforos near the town of Drama, about 130 km away of Thessaloniki. Finally, we plan to construct a third monitoring station at 58 MHz, in Thessaloniki. This frequency was revealed to be relatively free of interference, after a thorough investigation of the region.

  5. 47 CFR 80.379 - Maritime frequencies assignable to aircraft stations.

    Science.gov (United States)

    2010-10-01

    ....300 MHz (5) 156.375 MHz (5) 156.400 MHz (5) 156.425 MHz (5) 156.450 MHz (5) 156.625 MHz (5) 156.800... aircraft stations does not exceed 300 meters (1,000 feet), except for reconnaissance aircraft participating in icebreaking operations where an altitude of 450 meters (1,500 feet) is allowed; (ii) The mean...

  6. UMTS Network Stations

    Science.gov (United States)

    Hernandez, C.

    2010-09-01

    The weakness of small island electrical grids implies a handicap for the electrical generation with renewable energy sources. With the intention of maximizing the installation of photovoltaic generators in the Canary Islands, arises the need to develop a solar forecasting system that allows knowing in advance the amount of PV generated electricity that will be going into the grid, from the installed PV power plants installed in the island. The forecasting tools need to get feedback from real weather data in "real time" from remote weather stations. Nevertheless, the transference of this data to the calculation computer servers is very complicated with the old point to point telecommunication systems that, neither allow the transfer of data from several remote weather stations simultaneously nor high frequency of sampling of weather parameters due to slowness of the connection. This one project has developed a telecommunications infrastructure that allows sensorizadas remote stations, to send data of its sensors, once every minute and simultaneously, to the calculation server running the solar forecasting numerical models. For it, the Canary Islands Institute of Technology has added a sophisticated communications network to its 30 weather stations measuring irradiation at strategic sites, areas with high penetration of photovoltaic generation or that have potential to host in the future photovoltaic power plants connected to the grid. In each one of the stations, irradiance and temperature measurement instruments have been installed, over inclined silicon cell, global radiation on horizontal surface and room temperature. Mobile telephone devices have been installed and programmed in each one of the weather stations, which allow the transfer of their data taking advantage of the UMTS service offered by the local telephone operator. Every minute the computer server running the numerical weather forecasting models receives data inputs from 120 instruments distributed

  7. Principles of nuclear power station control

    International Nuclear Information System (INIS)

    Knowles, J.B.

    1975-12-01

    This memorandum represents lecture notes first distributed as part of a UKAEA introductory course on Reactor Technology held during November 1975. A nuclear power station is only one element of a dispersed interconnected arrangement of other nuclear and fossil-fired units which together constitute the national 'grid'. Thus the control of any one station must relate to the objectives of the grid network as a whole. A precise control of the supply frequency of the grid is achieved by regulating the output power of individual stations, and it is necessary for each station to be stable when operating in isolation with a variable load. As regards individual stations, several special control problems concerned with individual plant items are discussed, such as: controlled reactivity insertions, temperature reactivity time constants and flow instability. A simplified analysis establishes a fundamental relationship between the stored thermal energy of a boiler unit (a function of mechanical construction) and the flexibility of the heat source (nuclear or fossil-fired) if the station is to cope satisfactorily with demands arising from unscheduled losses of other generating sets or transmission capacity. Two basic control schemes for power station operation are described known as 'coupled' and 'decoupled control'. Each of the control modes has its own merits, which depend on the proposed station operating strategy (base load or load following) and the nature of the heat source. (U.K.)

  8. New hybrid frequency reuse method for packet loss minimization in LTE network.

    Science.gov (United States)

    Ali, Nora A; El-Dakroury, Mohamed A; El-Soudani, Magdi; ElSayed, Hany M; Daoud, Ramez M; Amer, Hassanein H

    2015-11-01

    This paper investigates the problem of inter-cell interference (ICI) in Long Term Evolution (LTE) mobile systems, which is one of the main problems that causes loss of packets between the base station and the mobile station. Recently, different frequency reuse methods, such as soft and fractional frequency reuse, have been introduced in order to mitigate this type of interference. In this paper, minimizing the packet loss between the base station and the mobile station is the main concern. Soft Frequency Reuse (SFR), which is the most popular frequency reuse method, is examined and the amount of packet loss is measured. In order to reduce packet loss, a new hybrid frequency reuse method is implemented. In this method, each cell occupies the same bandwidth of the SFR, but the total system bandwidth is greater than in SFR. This will provide the new method with a lot of new sub-carriers from the neighboring cells to reduce the ICI which represents a big problem in many applications and causes a lot of packets loss. It is found that the new hybrid frequency reuse method has noticeable improvement in the amount of packet loss compared to SFR method in the different frequency bands. Traffic congestion management in Intelligent Transportation system (ITS) is one of the important applications that is affected by the packet loss due to the large amount of traffic that is exchanged between the base station and the mobile node. Therefore, it is used as a studied application for the proposed frequency reuse method and the improvement in the amount of packet loss reached 49.4% in some frequency bands using the new hybrid frequency reuse method.

  9. Characterization of site conditions for selected seismic stations in eastern part of Romania

    Science.gov (United States)

    Grecu, B.; Zaharia, B.; Diaconescu, M.; Bala, A.; Nastase, E.; Constantinescu, E.; Tataru, D.

    2018-02-01

    Strong motion data are essential for seismic hazard assessment. To correctly understand and use this kind of data is necessary to have a good knowledge of local site conditions. Romania has one of the largest strong motion networks in Europe with 134 real-time stations. In this work, we aim to do a comprehensive site characterization for eight of these stations located in the eastern part of Romania. We make use of a various seismological dataset and we perform ambient noise and earthquake-based investigations to estimate the background noise level, the resonance frequencies and amplification of each site. We also derive the Vs30 parameter from the surface shear-wave velocity profiles obtained through the inversion of the Rayleigh waves recorded in active seismic measurements. Our analyses indicate similar results for seven stations: high noise levels for frequencies larger than 1 Hz, well defined fundamental resonance at low frequencies (0.15-0.29 Hz), moderate amplification levels (up to 4 units) for frequencies between 0.15 and 5-7 Hz and same soil class (type C) according to the estimated Vs30 and Eurocode 8. In contrast, the eighth station for which the soil class is evaluated of type B exhibits a very good noise level for a wide range of frequencies (0.01-20 Hz), a broader fundamental resonance at high frequencies ( 8 Hz) and a flat amplification curve between 0.1 and 3-4 Hz.

  10. Reliabilty worth: Development of a relationship with outage magnitude, duration and frequency

    International Nuclear Information System (INIS)

    Turner, F.P.P.; Katrichak, A.M.; Dwyer, A.; Edwards, D.; Ibrahim, A.

    1994-01-01

    British Columbia Hydro's Worth Project Team was founded to determine values for reliability for reference in evaluation of investment and operating decisions. Work to date has produced key preliminary values for specific outages and concepts for the shape of the relationship between value and these determinates of reliability worth, frequency, magnitude and duration. These values and concepts are described. The values are developed through an iterative, trial and refinement approach. The approach incorporates direct input from customers, common sense and judgement, and micro- and macro-economic concepts. Reliability worth values for reduced or prevented outages are presented for residential, commercial, small industrial and mixed sectors and various outage durations. Reliability worth values were obtained through customer surveys. Limitations of the reliability worth value are numerous and are listed. Study of cost vs magnitude of interruption using microeconomic models has shown that costly system improvements to reduce the possibility of widespread outages may not be justified. The case of exceptionally large area outages (blackouts) is examined. The cost vs frequency relationship was examined in terms of the economic concept of utility or satisfaction. Different loss/frequency characteristics are demonstrated for different customer classes. Customer value for reduced outage duration is expressed in a curve with flatter slope than that for eliminated outages. 2 refs., 6 figs

  11. Revision of IRIS/IDA Seismic Station Metadata

    Science.gov (United States)

    Xu, W.; Davis, P.; Auerbach, D.; Klimczak, E.

    2017-12-01

    Trustworthy data quality assurance has always been one of the goals of seismic network operators and data management centers. This task is considerably complex and evolving due to the huge quantities as well as the rapidly changing characteristics and complexities of seismic data. Published metadata usually reflect instrument response characteristics and their accuracies, which includes zero frequency sensitivity for both seismometer and data logger as well as other, frequency-dependent elements. In this work, we are mainly focused studying the variation of the seismometer sensitivity with time of IRIS/IDA seismic recording systems with a goal to improve the metadata accuracy for the history of the network. There are several ways to measure the accuracy of seismometer sensitivity for the seismic stations in service. An effective practice recently developed is to collocate a reference seismometer in proximity to verify the in-situ sensors' calibration. For those stations with a secondary broadband seismometer, IRIS' MUSTANG metric computation system introduced a transfer function metric to reflect two sensors' gain ratios in the microseism frequency band. In addition, a simulation approach based on M2 tidal measurements has been proposed and proven to be effective. In this work, we compare and analyze the results from three different methods, and concluded that the collocated-sensor method is most stable and reliable with the minimum uncertainties all the time. However, for epochs without both the collocated sensor and secondary seismometer, we rely on the analysis results from tide method. For the data since 1992 on IDA stations, we computed over 600 revised seismometer sensitivities for all the IRIS/IDA network calibration epochs. Hopefully further revision procedures will help to guarantee that the data is accurately reflected by the metadata of these stations.

  12. Cloud Compute for Global Climate Station Summaries

    Science.gov (United States)

    Baldwin, R.; May, B.; Cogbill, P.

    2017-12-01

    Global Climate Station Summaries are simple indicators of observational normals which include climatic data summarizations and frequency distributions. These typically are statistical analyses of station data over 5-, 10-, 20-, 30-year or longer time periods. The summaries are computed from the global surface hourly dataset. This dataset totaling over 500 gigabytes is comprised of 40 different types of weather observations with 20,000 stations worldwide. NCEI and the U.S. Navy developed these value added products in the form of hourly summaries from many of these observations. Enabling this compute functionality in the cloud is the focus of the project. An overview of approach and challenges associated with application transition to the cloud will be presented.

  13. Air ingression calculations for selected plant transients using MELCOR

    International Nuclear Information System (INIS)

    Kmetyk, L.N.

    1994-01-01

    Two sets of MELCOR calculations have been completed studying the effects of air ingression on the consequences of various severe accident scenarios. One set of calculations analyzed a station blackout with surge line failure prior to vessel breach, starting from nominal operating conditions; the other set of calculations analyzed a station blackout occurring during shutdown (refueling) conditions. Both sets of analyses were for the Surry plant, a three-loop Westinghouse PWR. For both accident scenarios, a basecase calculation was done, and then repeated with air ingression from containment into the core region following core degradation and vessel failure. In addition to the two sets of analyses done for this program, a similar air-ingression sensitivity study was done as part of a low-power/shutdown PRA, with results summarized here; that PRA study also analyzed a station blackout occurring during shutdown (refueling) conditions, but for the Grand Gulf plant, a BWR/6 with Mark III containment. These studies help quantify the amount of air that would have to enter the core region to have a significant impact on the severe accident scenario, and demonstrate that one effect, of air ingression is substantial enhancement of ruthenium release. These calculations also show that, while the core clad temperatures rise more quickly due to oxidation with air rather than steam, the core also degrades and relocates more quickly, so that no sustained, enhanced core heatup is predicted to occur with air ingression

  14. Alcohol advertising at Boston subway stations: an assessment of exposure by race and socioeconomic status.

    Science.gov (United States)

    Gentry, Elisabeth; Poirier, Katie; Wilkinson, Tiana; Nhean, Siphannay; Nyborn, Justin; Siegel, Michael

    2011-10-01

    We investigated the frequency of alcohol ads at all 113 subway and streetcar stations in Boston and the patterns of community exposure stratified by race, socioeconomic status, and age. We assessed the extent of alcohol advertising at each station in May 2009. We measured gross impressions and gross rating points (GRPs) for the entire Greater Boston population and for Boston public school student commuters. We compared the frequency of alcohol advertising between neighborhoods with differing demographics. For the Greater Boston population, alcohol advertising at subway stations generated 109 GRPs on a typical day. For Boston public school students in grades 5 to 12, alcohol advertising at stations generated 134 GRPs. Advertising at stations in low-poverty neighborhoods generated 14.1 GRPs and at stations in high-poverty areas, 63.6 GRPs. Alcohol ads reach the equivalent of every adult in the Greater Boston region and the equivalent of every 5th- to 12th-grade public school student each day. More alcohol ads were displayed in stations in neighborhoods with high poverty rates than in stations in neighborhoods with low poverty rates.

  15. Installing the earth station of Ka-band satellite frequency in Malaysia: conceptual framework for site decision

    Science.gov (United States)

    Mahmud, M. R.; Reba, M. N. M.; Jaw, S. W.; Arsyad, A.; Ibrahim, M. A. M.

    2017-05-01

    This paper developed a conceptual framework in determining the suitable location in installing the earth station for Ka-band satellite communication in Malaysia. This current evolution of high throughput satellites experienced major challenge due to Malaysian climate. Because Ka-band frequency is highly attenuated by the rainfall; it is an enormous challenge to define the most appropriate site for the static communication. Site diversity, a measure to anticipate this conflict by choosing less attenuated region and geographically change the transmission strategy on season basis require accurate spatio-temporal information on the geographical, environmental and hydro-climatology at local scale. Prior to that request, this study developed a conceptual framework to cater the needs. By using the digital spatial data, acquired from site measurement and remote sensing, the proposed framework applied a multiple criteria analysis to perform the tasks of site selection. With the advancement of high resolution remotely sensed data, site determination can be conducted as in Malaysia; accommodating a new, fast, and effective satellite communication. The output of this study is one of the pioneer contributions to create a high tech-society.

  16. A Kalman-based Fundamental Frequency Estimation Algorithm

    DEFF Research Database (Denmark)

    Shi, Liming; Nielsen, Jesper Kjær; Jensen, Jesper Rindom

    2017-01-01

    Fundamental frequency estimation is an important task in speech and audio analysis. Harmonic model-based methods typically have superior estimation accuracy. However, such methods usually as- sume that the fundamental frequency and amplitudes are station- ary over a short time frame. In this pape...

  17. Suboptimal Choice in Pigeons: Stimulus Value Predicts Choice over Frequencies.

    Directory of Open Access Journals (Sweden)

    Aaron P Smith

    Full Text Available Pigeons have shown suboptimal gambling-like behavior when preferring a stimulus that infrequently signals reliable reinforcement over alternatives that provide greater reinforcement overall. As a mechanism for this behavior, recent research proposed that the stimulus value of alternatives with more reliable signals for reinforcement will be preferred relatively independently of their frequencies. The present study tested this hypothesis using a simplified design of a Discriminative alternative that, 50% of the time, led to either a signal for 100% reinforcement or a blackout period indicative of 0% reinforcement against a Nondiscriminative alternative that always led to a signal that predicted 50% reinforcement. Pigeons showed a strong preference for the Discriminative alternative that remained despite reducing the frequency of the signal for reinforcement in subsequent phases to 25% and then 12.5%. In Experiment 2, using the original design of Experiment 1, the stimulus following choice of the Nondiscriminative alternative was increased to 75% and then to 100%. Results showed that preference for the Discriminative alternative decreased only when the signals for reinforcement for the two alternatives predicted the same probability of reinforcement. The ability of several models to predict this behavior are discussed, but the terminal link stimulus value offers the most parsimonious account of this suboptimal behavior.

  18. Testing EDM of Total Stations

    Directory of Open Access Journals (Sweden)

    Cirbus Ján

    2001-03-01

    Full Text Available The paper is devoted to testing electrooptical distance measuring devices (EDM built in total stations, than can be used for various tasks in the contemporary geodetic works. A rich market offer and availability of these universal measuring systems with satisfying distance range, excellent accuracy and other parameters, make total stations as dominant terrestrial geodetic instruments.For succesfully applying these instruments, above all for relliable distance measurements, the stability of the modulation frequency is the most important pre-condition. In the article, therefore, there are given some methods to verify the modulation frequency stability. In addition, some ways for determining the EDM distance constant and periodical corrections of the phase measuring unit are introduced for 4 types of EDM : LEICA 1700L, TOPCON GTS6A, TOPCON GTS2, C.ZEISS ELTA50. It were also investigated their possibilities for precise distance survey. Values of the determined constants and periodical corrections are presented in Tab. 2.Based on the investigation results of the 4 EDM types and using the values m obtained for different distances S, equations of the a posteriori standard deviations in form : m = (a+b.S were derived too.

  19. Monitoring of Electromagnetic Radiation from Cellular Base Stations in Kuwait

    International Nuclear Information System (INIS)

    Al-Otaibi, A.H.; Al-Ajmi, D.; Williams, T.; McGee, D.; Dennis, J.A.; Beg, M.U.

    1998-01-01

    A survey of the radio frequency electromagnetic environment in Kuwait was carried out. The primary purpose of this survey was to monitor electromagnetic radiation (EMR) field strength levels emitted by cellular base stations installed and operated by the Kuwait Mobile Telecommunications Company (MTC). Measurements were made at 26 cellular-phone base stations, chosen as a representative sample to include 14 school sites, 2 residential sites, 2 hospital sites, 3 ministerial building sites, 3 commercial sites and 1 typical stand-alone site. On all the selected sites measurements were made with a spectrum analyser to determine the emission level in the frequency bands used by the base station transmitters (917-960 MHz). The results indicated that total field strength, specifically due to the MTC base stations, found in public access areas, varied generally between 0.05 and 1.13 V.m -1 . These values are in the order of between 40 and 800 times lower than the new pan-European CENELEC pre-standard ENV 50166-2 'Human Exposure to Electromagnetic Fields'. In terms of power density the highest observed value (0.34 μW.m -2 ) was more than a thousand times below the prescribed standards. (author)

  20. Methodology for Estimation of Flood Magnitude and Frequency for New Jersey Streams

    Science.gov (United States)

    Watson, Kara M.; Schopp, Robert D.

    2009-01-01

    Methodologies were developed for estimating flood magnitudes at the 2-, 5-, 10-, 25-, 50-, 100-, and 500-year recurrence intervals for unregulated or slightly regulated streams in New Jersey. Regression equations that incorporate basin characteristics were developed to estimate flood magnitude and frequency for streams throughout the State by use of a generalized least squares regression analysis. Relations between flood-frequency estimates based on streamflow-gaging-station discharge and basin characteristics were determined by multiple regression analysis, and weighted by effective years of record. The State was divided into five hydrologically similar regions to refine the regression equations. The regression analysis indicated that flood discharge, as determined by the streamflow-gaging-station annual peak flows, is related to the drainage area, main channel slope, percentage of lake and wetland areas in the basin, population density, and the flood-frequency region, at the 95-percent confidence level. The standard errors of estimate for the various recurrence-interval floods ranged from 48.1 to 62.7 percent. Annual-maximum peak flows observed at streamflow-gaging stations through water year 2007 and basin characteristics determined using geographic information system techniques for 254 streamflow-gaging stations were used for the regression analysis. Drainage areas of the streamflow-gaging stations range from 0.18 to 779 mi2. Peak-flow data and basin characteristics for 191 streamflow-gaging stations located in New Jersey were used, along with peak-flow data for stations located in adjoining States, including 25 stations in Pennsylvania, 17 stations in New York, 16 stations in Delaware, and 5 stations in Maryland. Streamflow records for selected stations outside of New Jersey were included in the present study because hydrologic, physiographic, and geologic boundaries commonly extend beyond political boundaries. The StreamStats web application was developed

  1. Final environmental assessment for vegetation control at VHF stations, microwave stations, electrical substations, and pole yards

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-13

    Southwestern Power Adm. operates very high frequency (VHF) and microwave radio stations, electrical substations, and pole yards for electric power transmission throughout AR, MO, and OK. Vegetation growth at the stations must be suppressed for safety of operation and personnel. Southwestern has been using a combination of mechanical/manual and herbicide control for this purpose; Federally- mandated reductions in staff and budgetary resources require Southwestern to evaluate all potentially efficient methods for vegetation control. Three alternatives were examined: no action, mechanical/manual control, and (proposed) a combination of mechanical/manual and herbicide control. Environmental impacts on air and water quality, wetlands, wildlife, endangered species, archaeological and other resources, farmland, human health, transportation, etc. were evaluated.

  2. Study of the GPS inter-frequency calibration of timing receivers

    Science.gov (United States)

    Defraigne, P.; Huang, W.; Bertrand, B.; Rovera, D.

    2018-02-01

    When calibrating Global Positioning System (GPS) stations dedicated to timing, the hardware delays of P1 and P2, the P(Y)-codes on frequencies L1 and L2, are determined separately. In the international atomic time (TAI) network the GPS stations of the time laboratories are calibrated relatively against reference stations. This paper aims at determining the consistency between the P1 and P2 hardware delays (called dP1 and dP2) of these reference stations, and to look at the stability of the inter-signal hardware delays dP1-dP2 of all the stations in the network. The method consists of determining the dP1-dP2 directly from the GPS pseudorange measurements corrected for the frequency-dependent antenna phase center and the frequency-dependent ionosphere corrections, and then to compare these computed dP1-dP2 to the calibrated values. Our results show that the differences between the computed and calibrated dP1-dP2 are well inside the expected combined uncertainty of the two quantities. Furthermore, the consistency between the calibrated time transfer solution obtained from either single-frequency P1 or dual-frequency P3 for reference laboratories is shown to be about 1.0 ns, well inside the 2.1 ns uB uncertainty of a time transfer link based on GPS P3 or Precise Point Positioning. This demonstrates the good consistency between the P1 and P2 hardware delays of the reference stations used for calibration in the TAI network. The long-term stability of the inter-signal hardware delays is also analysed from the computed dP1-dP2. It is shown that only variations larger than 2 ns can be detected for a particular station, while variations of 200 ps can be detected when differentiating the results between two stations. Finally, we also show that in the differential calibration process as used in the TAI network, using the same antenna phase center or using different positions for L1 and L2 signals gives maximum differences of 200 ps on the hardware delays of the separate

  3. Emergent transformation games: exploring social innovation agency and activation through the case of the Belgian electricity blackout threat

    Directory of Open Access Journals (Sweden)

    Bonno Pel

    2016-06-01

    Full Text Available The persistence of current societal problems has given rise to a quest for transformative social innovations. As social innovation actors seek to become change makers, it has been suggested that they need to play into impactful macrodevelopments or "game-changers". Here, we aim to deepen the understanding of the social innovation agency in these transformation games. We analyze assumptions about the game metaphor, invoking insights from actor-network theory. The very emergence of transformation games is identified as a crucial but easily overlooked issue. As explored through the recent electricity blackout threat in Belgium, some current transformation games are populated with largely passive players. This illustrative case demonstrates that socially innovative agency cannot be presupposed. In some transformation games, the crucial game-changing effect is to start the game by activating the players.

  4. Innovative safety features of VVER for ensuring high degree of autonomy during beyond design basis accidents

    International Nuclear Information System (INIS)

    Kumar, Abhay; Mohan, Joe; Kumar, Devesh; Chaudhry, S.M.; Rao, Srinivasa; Gupta, S.K.

    2010-01-01

    The effectiveness of Passive Heat Removal System (PHRS) in during a station black-out (SBO) accident was assessed by using SCDAP/Relap5. The analysis gave evidence that (i) the Passive Heat Removal System (PHRS) is capable of limiting the consequences of station black out (SBO) and acts as an effective engineered safety system, and (ii) the PHRS intervention prevents core degradation and excessive core heat-up. (P.A.)

  5. Emergency Diesel Generation System Surveillance Test Policy Optimization Through Genetic Algorithms Using Non-Periodic Intervention Frequencies and Seasonal Constraints

    International Nuclear Information System (INIS)

    Lapa, Celso M.F.; Pereira, Claudio M.N.A.; Frutuoso e Melo, P.F.

    2002-01-01

    Nuclear standby safety systems must frequently, be submitted to periodic surveillance tests. The main reason is to detect, as soon as possible, the occurrence of unrevealed failure states. Such interventions may, however, affect the overall system availability due to component outages. Besides, as the components are demanded, deterioration by aging may occur, penalizing again the system performance. By these reasons, planning a good surveillance test policy implies in a trade-off between gains and overheads due to the surveillance test interventions. In order maximize the systems average availability during a given period of time, it has recently been developed a non-periodic surveillance test optimization methodology based on genetic algorithms (GA). The fact of allowing non-periodic tests turns the solution space much more flexible and schedules can be better adjusted, providing gains in the overall system average availability, when compared to those obtained by an optimized periodic tests scheme. The optimization problem becomes, however, more complex. Hence, the use of a powerful optimization technique, such as GAs, is required. Some particular features of certain systems can turn it advisable to introduce other specific constraints in the optimization problem. The Emergency Diesel Generation System (EDGS) of a Nuclear Power Plant (N-PP) is a good example for demonstrating the introduction of seasonal constraints in the optimization problem. This system is responsible for power supply during an external blackout. Therefore, it is desirable during periods of high blackout probability to maintain the system availability as high as possible. Previous applications have demonstrated the robustness and effectiveness of the methodology. However, no seasonal constraints have ever been imposed. This work aims at investigating the application of such methodology in the Angra-II Brazilian NPP EDGS surveillance test policy optimization, considering the blackout probability

  6. Assessment of Extremely Low Frequency (ELF Electric and Magnetic Fields in Hamedan High Electrical Power Stations and their Effects on Workers

    Directory of Open Access Journals (Sweden)

    Farshid Ghorbani Shahna

    2011-09-01

    Full Text Available Introduction: Public and occupational exposure to extremely low frequency (ELF electric and magnetic fields induced by electrical equipment is a significant issue in the environment and at the workplace due to their potential health effects on public health. The purpose of this study was assessment of the electric and magnetic fields intensities and determination of mental and psychological effects of occupational exposure in the high voltage electric power stations in the city of Hamadan, Iran. Material and Methods: The intensities of the magnetic and electric fields were measured at eight high voltage electric power stations at three different intervals of sources using an HI-3604 instrument. A two-part questionnaire was used to assess mental and psychological effects of the exposure to these fields. Two groups of control and case workers including 30 samples were selected to determine the exposure effects. Results: The results of field measurements showed the highest average electric field intensity was related to the CVT unit with 3110 V/m at a 2 m distance from the source and the lowest average was related to the control room with 1.35 V/m next to the source. Also, the highest and lowest magnetic field intensities were close to the transformator 2 and the battery room (50.42 and 1.31 mG, respectively. Discussion and Conclusion: The intensities of electric and magnetic fields in the selected stations are lower than the ACGIH and ICNIRP standard levels for occupational exposures. The results obtained indicate that the distribution of these fields was nonlinear around the sources and the effects observed on exposed workers were non-thermal.

  7. Modeling of temporal variation of very low frequency radio waves over long paths as observed from Indian Antarctic stations

    Science.gov (United States)

    Sasmal, Sudipta; Basak, Tamal; Chakraborty, Suman; Palit, Sourav; Chakrabarti, Sandip K.

    2017-07-01

    Characteristics of very low frequency (VLF) signal depends on solar illumination across the propagation path. For a long path, solar zenith angle varies widely over the path and this has a significant influence on the propagation characteristics. To study the effect, Indian Centre for Space Physics participated in the 27th and 35th Scientific Expedition to Antarctica. VLF signals transmitted from the transmitters, namely, VTX (18.2 kHz), Vijayanarayanam, India, and NWC (19.8 kHz), North West Cape, Australia, were recorded simultaneously at Indian permanent stations Maitri and Bharati having respective geographic coordinates 70.75°S, 11.67°E, and 69.4°S, 76.17°E. A very stable diurnal variation of the signal has been obtained from both the stations. We reproduced the signal variations of VLF signal using solar zenith angle model coupled with long wavelength propagation capability (LWPC) code. We divided the whole path into several segments and computed the solar zenith angle (χ) profile. We assumed a linear relationship between the Wait's exponential model parameters effective reflection height (h'), steepness parameter (β), and solar zenith angle. The h' and β values were later used in the LWPC code to obtain the VLF signal amplitude at a particular time. The same procedure was repeated to obtain the whole day signal. Nature of the whole day signal variation from the theoretical modeling is also found to match with our observation to some extent.

  8. Source Term Analysis for the Nuclear Power Station Goesgen-Daeniken; Quelltermanalysen fuer das Kernkraftwerk Goesgen-Daeniken

    Energy Technology Data Exchange (ETDEWEB)

    Hosemann, J.P.; Megaritis, G.; Guentay, S.; Hirschmann, H.; Luebbesmeyer, D.; Lieber, K.; Jaeckel, B.; Birchley, J.; Duijvestijn, G

    2001-08-01

    Analyses are performed for three accident scenarios postulated to occur in the Goesgen Nuclear Power Plant, a 900 MWe Pressurised Water Reactor of Siemens design. The scenarios investigated comprise a Station Blackout and two separate cases of small break loss-of-coolant accident which lead, respectively, to high, intermediate and low pressure conditions in the reactor system. In each case the accident assumptions are highly pessimistic, so that the sequences span a large range of plant states and a damage phenomena. Thus the plant is evaluated for a diversity of potential safety challenges. A suite of analysis tools are used to examine the reactor coolant system response, the core heat-up, melting, fission product release from the reactor system, the transport and chemical behaviour of those fission products in the containment building, and the release of radioactivity (source term) to the environment. Comparison with reference values used by the licensing authority shows that the use of modern analysis tools and current knowledge can provide substantial reduction in the estimated source term. Of particular interest are insights gained from the analyses which indicate opportunities for operators to reduce or forestall the release. (author)

  9. In situ radio-frequency heating for soil remediation at a former service station: case study and general aspects

    Energy Technology Data Exchange (ETDEWEB)

    Huon, G.; Simpson, T.; Maini, G. [Ecologia Environmental Solutions Ltd., Sittingbourne, Kent (United Kingdom); Holzer, F.; Kopinke, F.D.; Roland, U. [Helmholtz Centre for Environmental Research - UFZ, Department of Environmental Engineering, Leipzig (Germany); Will, F. [Total UK, Watford (United Kingdom)

    2012-08-15

    In situ radio-frequency heating (ISRFH) was successfully applied during remediation of a former petrol station. Using a three-electrode array in combination with extraction wells for soil vapor extraction (SVE), pollution consisting mainly of benzene, toluene, ethylbenzene, xylenes, and mineral oil hydrocarbons (in total about 1100 kg) was eliminated from a chalk soil in the unsaturated zone. Specially designed rod electrodes allowed selective heating of a volume of approximately 480 m{sup 3}, at a defined depth, to a mean temperature of about 50 C. The heating drastically increased the extraction rates. After switching off ISRFH, SVE remained highly efficient for some weeks due to the heat-retaining properties of the soil. Comparison of an optimized regime of ISRFH/SVE with conventional ''cold'' SVE showed a reduction of remediation time by about 80 % while keeping the total energy consumption almost constant. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Rf Station For Ion Beam Staking In Hirfl-csr

    CERN Document Server

    Arbuzov, V S; Bushuev, A A; Dranichnikov, A N; Gorniker, E I; Kendjebulatov, E K; Kondakov, A A; Kondaurov, M; Kruchkov, Ya G; Krutikhin, S A; Kurkin, G Ya; Mironenko, L A; Motygin, S V; Osipov, V N; Petrov, V M; Pilan, Andrey M; Popov, A M; Rashenko, V V; Selivanov, A N; Shteinke, A R; Vajenin, N F

    2004-01-01

    BINP has developed and produced the RF station for Institute of Modern Physics (IMP), Lanzhou, China, for multipurpose accelerator complex with electron cooling. The RF station will be used for accumulation of ion beams in the main ring of the system. It was successfully tested in IMP and installed into the main accelerator ring of the complex. The RF station includes accelerating RF cavity and RF power generator with power supplies. The station works within frequency range 6.0 - 14.0 MHz, maximum voltage across the accelerating gap of the RF cavity - 20 kV. In the RF cavity the 200 VNP ferrite is utilized. A residual gas pressure in vacuum chamber does not exceed 2,5E-11 mbar. Maximum output power of the RF generator 25 kW. The data acquisition and control of the RF station is based on COMPACT - PCI bus and provides all functions of monitoring and control.

  11. 47 CFR 80.313 - Frequencies for use in distress.

    Science.gov (United States)

    2010-10-01

    ... 80.313 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety Procedures § 80.313 Frequencies for use in distress. The frequencies specified in the...

  12. Numerical solution of optimal departure frequency of Taipei TMS

    Science.gov (United States)

    Young, Lih-jier; Chiu, Chin-Hsin

    2016-05-01

    Route Number 5 (Bannan Line) of Taipei Mass Rapid Transit (MRT) is the most popular line in the Taipei Metro System especially during rush hours periods. It has been estimated there are more than 8,000 passengers on the ticket platform during 18:00∼19:00 at Taipei main station. The purpose of this research is to predict a specific departure frequency of passengers per train. Monte Carlo Simulation will be used to optimize departure frequency according to the passenger information provided by 22 stations, i.e., 22 random variables of route number 5. It is worth mentioning that we used 30,000 iterations to get the different samples of the optimization departure frequency, i.e., 10 trains/hr which matches the practical situation.

  13. A biomonitoring study of genotoxic risk to workers of transformers and distribution line stations.

    Science.gov (United States)

    Celikler, Serap; Aydemir, Nilufer; Vatan, Ozgur; Kurtuldu, Sevim; Bilaloglu, Rahmi

    2009-12-01

    A cytogenetic monitoring study was carried out on a group of workers from transformer and distribution line stations in the Bursa province of Turkey, to investigate the genotoxic risk of occupational exposure to extremely low frequency electric (ELF) and magnetic fields (EMF). Cytogenetic analysis, namely chromosomal aberrations (CAs) and micronucleus (MN) tests were performed on a strictly selected group of 55 workers and compared to 17 controls. CA and MN frequencies in electrical workers appeared significantly higher than in controls (p electric transformer and distribution stations.

  14. Utilities must leverage existing resources and upgrade technology to avoid future blackouts

    International Nuclear Information System (INIS)

    Masiello, R.

    2004-01-01

    The blackout of August 14, 2003 is used as the incentive to examine transmission grid reliability, expose its deficiencies in terms of technology, standards and processes used to manage reliability, and to make recommendations for leveraging existing resources and upgrading both the technology and procedures to avoid similar breakdowns in the future. It is recommended that in the area of monitoring transmission grid reliability utilities should borrow a page from the Enterprise Risk Management Practices of the financial industry by adopting a system which looks beyond the first 'credible' contingency (the current system) and examine many more 'incredible' contingencies, and underlying events that can trigger multiple contingencies, and plan for them in their operations. Utility companies are also urged to upgrade their energy management systems (EMS) technology to be able to deal with the kinds of severely depressed voltages and overloaded circuits that many grids experience today. Investment in new capabilities in control rooms, more and better communications will be essential. EMS algorithms and models must be upgraded to operate under a broader spectrum of grid conditions and to simulate the once-in-a-lifetime outage scenarios that most operators believe could never strike their utility. Expert opinion strongly suggests that as part of this process of upgrading, contingency analysis should shift from the 'N-1' model of the present to a stochastic model that considers a wider range of possible events in a probabilistic framework

  15. Utilities must leverage existing resources and upgrade technology to avoid future blackouts

    Energy Technology Data Exchange (ETDEWEB)

    Masiello, R. [KEMA Inc. Burlington, MA (United States)

    2004-06-01

    The blackout of August 14, 2003 is used as the incentive to examine transmission grid reliability, expose its deficiencies in terms of technology, standards and processes used to manage reliability, and to make recommendations for leveraging existing resources and upgrading both the technology and procedures to avoid similar breakdowns in the future. It is recommended that in the area of monitoring transmission grid reliability utilities should borrow a page from the Enterprise Risk Management Practices of the financial industry by adopting a system which looks beyond the first 'credible' contingency (the current system) and examine many more 'incredible' contingencies, and underlying events that can trigger multiple contingencies, and plan for them in their operations. Utility companies are also urged to upgrade their energy management systems (EMS) technology to be able to deal with the kinds of severely depressed voltages and overloaded circuits that many grids experience today. Investment in new capabilities in control rooms, more and better communications will be essential. EMS algorithms and models must be upgraded to operate under a broader spectrum of grid conditions and to simulate the once-in-a-lifetime outage scenarios that most operators believe could never strike their utility. Expert opinion strongly suggests that as part of this process of upgrading, contingency analysis should shift from the 'N-1' model of the present to a stochastic model that considers a wider range of possible events in a probabilistic framework.

  16. Design of an MSAT-X mobile transceiver and related base and gateway stations

    Science.gov (United States)

    Fang, Russell J. F.; Bhaskar, Udaya; Hemmati, Farhad; Mackenthun, Kenneth M.; Shenoy, Ajit

    This paper summarizes the results of a design study of the mobile transceiver, base station, and gateway station for NASA's proposed Mobile Satellite Experiment (MSAT-X). Major ground segment system design issues such as frequency stability control, modulation method, linear predictive coding vocoder algorithm, and error control technique are addressed. The modular and flexible transceiver design is described in detail, including the core, RF/IF, modem, vocoder, forward error correction codec, amplitude-companded single sideband, and input/output modules, as well as the flexible interface. Designs for a three-carrier base station and a 10-carrier gateway station are also discussed, including the interface with the controllers and with the public-switched telephone networks at the gateway station. Functional specifications are given for the transceiver, the base station, and the gateway station.

  17. Design of an MSAT-X mobile transceiver and related base and gateway stations

    Science.gov (United States)

    Fang, Russell J. F.; Bhaskar, Udaya; Hemmati, Farhad; Mackenthun, Kenneth M.; Shenoy, Ajit

    1987-01-01

    This paper summarizes the results of a design study of the mobile transceiver, base station, and gateway station for NASA's proposed Mobile Satellite Experiment (MSAT-X). Major ground segment system design issues such as frequency stability control, modulation method, linear predictive coding vocoder algorithm, and error control technique are addressed. The modular and flexible transceiver design is described in detail, including the core, RF/IF, modem, vocoder, forward error correction codec, amplitude-companded single sideband, and input/output modules, as well as the flexible interface. Designs for a three-carrier base station and a 10-carrier gateway station are also discussed, including the interface with the controllers and with the public-switched telephone networks at the gateway station. Functional specifications are given for the transceiver, the base station, and the gateway station.

  18. Development of filtered containment venting system and application for Kashiwazaki-Kariwa Nuclear Power Station Unit 6, 7

    International Nuclear Information System (INIS)

    Murai, Soutarou; Hiranuma, Naoki; Kimura, Takeo; Omori, Shuichi; Watanabe, Fumitoshi; Sasa, Daisuke

    2014-01-01

    The Fukushima Dai-ichi Nuclear Power Station (1F) of Tokyo Electric Power Company (TEPCO) had experienced severe radio-active release to the environment in the Tohoku Region Pacific Coast Earthquake (alias: the Great East Japan Earthquake) in 2011. Under the Station Black-Out (SBO) conditions caused by tsunami with the earthquake, the 1F operators had tried to vent the gasses in the Primary Containment Vessels (PCVs) of the unit 1, 2 and 3 to the environment through the water pools in the suppression chambers of the PCVs. Its venting, however, was imperfect and, as a result, major direct radio-active release to the environment was caused. After this disaster, TEPCO launched a project to develop the Filtered Containment Venting System (FCVS), in which our very bitter experiences in the 1F accident as described above are reflected. One of the main purposes of the development of the FCVS is to enhance operability of venting under the severe plant conditions such as the SBO during progressing of severe core damage, and another is to enhance removal performance of radio-nuclides with the newly added filtering equipment, which is installed in the venting line from the PCV to the outer. The Kashiwazaki-Kariwa NPS unit 6 and 7 will be the first reactors applied the FCVSs. In this paper, we show the design concept of the TEPCO's FCVS, the brief overview of the system design and the summary of experiment which has been performed for getting the performance data of the FCVS such as decontamination factor in various conditions. (author)

  19. Preliminary Assessment of Radiofrequency Radiation Exposure Level, From Mobile Base Stations in Ajaokuta and Environs, Kogi State, Nigeria

    International Nuclear Information System (INIS)

    Ushie, P. O.; Nwankwo, U.J.V.; Osahun, O. D.; Ayinmode, B.

    2013-01-01

    We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs using radio frequency (RF) meter (electromoge meter). The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of unavoidable factors suspected to be interferences from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is far below the standard limit (10W/cm 2 or 10 7 μW/m 2 ) set by the International Commission on Non-ionizing Radiation Protection (ICNIRP) regulatory agencies. The assessment was done in about ten (10) base stations in Ajaokuta, Kogi state. The position and elevation of the base stations were noted using a global positioning system (GPS) to ascertain the position of such stations on the world map. It was discovered that the limit of exposure to radio frequency radiation set by International Commission on Non-ionizing, Radiation Protection (ICNIRP) of 900MHz band expressed in the same unit as 10W/cm 2 or 10 7 μW/m 2 was not exceeded, the values were also influenced by some inevitable factors. Positions of most of the stations are sited close to homes.

  20. Modeling of a Flooding Induced Station Blackout for a Pressurized Water Reactor Using the RISMC Toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Mandelli, Diego; Prescott, Steven R; Smith, Curtis L; Alfonsi, Andrea; Rabiti, Cristian; Cogliati, Joshua J; Kinoshita, Robert A

    2011-07-01

    In the Risk Informed Safety Margin Characterization (RISMC) approach we want to understand not just the frequency of an event like core damage, but how close we are (or are not) to key safety-related events and how might we increase our safety margins. The RISMC Pathway uses the probabilistic margin approach to quantify impacts to reliability and safety by coupling both probabilistic (via stochastic simulation) and mechanistic (via physics models) approaches. This coupling takes place through the interchange of physical parameters and operational or accident scenarios. In this paper we apply the RISMC approach to evaluate the impact of a power uprate on a pressurized water reactor (PWR) for a tsunami-induced flooding test case. This analysis is performed using the RISMC toolkit: RELAP-7 and RAVEN codes. RELAP-7 is the new generation of system analysis codes that is responsible for simulating the thermal-hydraulic dynamics of PWR and boiling water reactor systems. RAVEN has two capabilities: to act as a controller of the RELAP-7 simulation (e.g., system activation) and to perform statistical analyses (e.g., run multiple RELAP-7 simulations where sequencing/timing of events have been changed according to a set of stochastic distributions). By using the RISMC toolkit, we can evaluate how power uprate affects the system recovery measures needed to avoid core damage after the PWR lost all available AC power by a tsunami induced flooding. The simulation of the actual flooding is performed by using a smooth particle hydrodynamics code: NEUTRINO.

  1. Experimental research of variable rotation speed ICE-based electric power station

    Directory of Open Access Journals (Sweden)

    Dar’enkov Andrey

    2017-01-01

    Full Text Available Developing variable rotation speed ICE-based stand-alone electric power stations which can supply distant regions and autonomous objects with electricity are of scientific interest due to the insufficient study. The relevance of developing such electric power stations is determined by their usage is to provide a significant fuel saving as well as increase ICE motor service life. The article describes the electric station of autonomous objects with improved fuel economy. The article describes multivariate characteristic. Multivariate characteristic shows the optimal frequency of rotation of the internal combustion engine. At this rotational speed there is the greatest fuel economy.

  2. Radionuclide release calculations for selected severe accident scenarios

    International Nuclear Information System (INIS)

    Denning, R.S.; Leonard, M.T.; Cybulskis, P.; Lee, K.W.; Kelly, R.F.; Jordan, H.; Schumacher, P.M.; Curtis, L.A.

    1990-08-01

    This report provides the results of source term calculations that were performed in support of the NUREG-1150 study. ''Severe Accident Risks: An Assessment for Five US Nuclear Power Plants.'' This is the sixth volume of a series of reports. It supplements results presented in the earlier volumes. Analyses were performed for three of the NUREG-1150 plants: Peach Bottom, a Mark I, boiling water reactor; Surry, a subatmospheric containment, pressurized water reactor; and Sequoyah, an ice condenser containment, pressurized water reactor. Complete source term results are presented for the following sequences: short term station blackout with failure of the ADS system in the Peach Bottom plant; station blackout with a pump seal LOCA for the Surry plant; station blackout with a pump seal LOCA in the Sequoyah plant; and a very small break with loss of ECC and spray recirculation in the Sequoyah plant. In addition, some partial analyses were performed which did not require running all of the modules of the Source Term Code Package. A series of MARCH3 analyses were performed for the Surry and Sequoyah plants to evaluate the effects of alternative emergency operating procedures involving primary and secondary depressurization on the progress of the accident. Only thermal-hydraulic results are provided for these analyses. In addition, three accident sequences were analyzed for the Surry plant for accident-induced failure of steam generator tubes. In these analyses, only the transport of radionuclides within the primary system and failed steam generator were examined. The release of radionuclides to the environment is presented for the phase of the accident preceding vessel meltthrough. 17 refs., 176 figs., 113 tabs

  3. Volcano Popocatepetl, Mexico: ULF geomagnetic anomalies observed at Tlamacas station during March–July, 2005

    Directory of Open Access Journals (Sweden)

    A. Kotsarenko

    2007-01-01

    Full Text Available In this paper the first results of ULF (Ultra Low Frequency geomagnetic anomalies observed at Tlamacas station (Long. 261.37, Lat. 19.07 located at 4 km near the volcano Popocatepetl (active volcano, Long. 261.37, Lat. 19.02 for the period March–July, 2005 and their analysis are presented. The geomagnetic data were collected with a 3-axial fluxgate magnetometer designed at UCLA (University of California, Los Angeles, 1 Hz sampling rate frequency, GPS. Our analysis reveals some anomalies which are suspected to be generated by local volcanic origin: the EM background in the vicinity of the volcano is significantly noisier than in other reference stations; the sporadic strong noise-like geomagnetic activity observed in the H-component; locally generated geomagnetic pulsations (without preferred polarization are detected only at Tlamacas station.

  4. Reliability of emergency ac power systems at nuclear power plants

    International Nuclear Information System (INIS)

    Battle, R.E.; Campbell, D.J.

    1983-07-01

    Reliability of emergency onsite ac power systems at nuclear power plants has been questioned within the Nuclear Regulatory Commission (NRC) because of the number of diesel generator failures reported by nuclear plant licensees and the reactor core damage that could result from diesel failure during an emergency. This report contains the results of a reliability analysis of the onsite ac power system, and it uses the results of a separate analysis of offsite power systems to calculate the expected frequency of station blackout. Included is a design and operating experience review. Eighteen plants representative of typical onsite ac power systems and ten generic designs were selected to be modeled by fault trees. Operating experience data were collected from the NRC files and from nuclear plant licensee responses to a questionnaire sent out for this project

  5. Analysis of Synchronization Impairments for Cooperative Base Stations Using OFDM

    Directory of Open Access Journals (Sweden)

    Konstantinos Manolakis

    2015-01-01

    Full Text Available Base station cooperation is envisioned as a key technology for future cellular networks, as it has the potential to eliminate intercell interference and to enhance spectral efficiency. To date, there is still lack of understanding of how imperfect carrier and sampling frequency synchronization between transmitters and receivers limit the potential gains and what the actual system requirements are. In this paper, OFDM signal model is established for multiuser multicellular networks, describing the joint effect of multiple carrier and sampling frequency offsets. It is shown that the impact of sampling offsets is much smaller than the impact of carrier frequency offsets. The model is extended to the downlink of base-coordinated networks and closed-form expressions are derived for the mean power of users’ self-signal, interuser, and intercarrier interference, whereas it is shown that interuser interference is the main source of degradation. The SIR is inverse to the base stations’ carrier frequency variance and to the square of time since the last precoder update, whereas it grows with the number of base stations and drops with the number of users. Through user selection, the derived SIR upper bound can be approached. Finally, system design recommendations for meeting synchronization requirements are provided.

  6. Source term analysis in severe accident induced by large break loss of coolant accident coincident with ship blackout for ship reactor

    International Nuclear Information System (INIS)

    Zhang Yanzhao; Zhang Fan; Zhao Xinwen; Zheng Yingfeng

    2013-01-01

    Using MELCOR code, the accident analysis model was established for a ship reactor. The behaviors of radioactive fission products were analyzed in the case of severe accident induced by large break loss of coolant accident coincident with ship blackout. The research mainly focused on the behaviors of release, transport, retention and the final distribution of inert gas and CsI. The results show that 83.12% of inert gas releases from the core, and the most of inert gas exists in the containment. About 83.08% of CsI release from the core, 72.66% of which is detained in the debris and the primary system, and 27.34% releases into the containment. The results can give a reference for the evaluation of cabin dose and nuclear emergency management. (authors)

  7. Development of a method to evaluate shared alternate AC power source effects in multi-unit nuclear power plants

    International Nuclear Information System (INIS)

    Jung, Woo Sik; Yang, Joon Eun

    2003-07-01

    In order to evaluate accurately a Station BlackOut (SBO) event frequency of a multi-unit nuclear power plant that has a shared Alternate AC (AAC) power source, an approach has been developed which accommodates the complex inter-unit behavior of the shared AAC power source under multi-unit Loss Of Offsite Power (LOOP) conditions. The approach is illustrated for two cases, 2 units and 4 units at a single site, and generalized for a multi-unit site. Furthermore, the SBO frequency of the first unit of the 2-unit site is quantified. The SBO frequency at a target unit of Probabilistic Safety Assessment (PSA) could be underestimated if the inter-unit dependency of the shared AAC power source is not properly modeled. The effect of the inter-unit behavior of the shared AAC power source on the SBO frequency is not negligible depending on the Common Cause Failure (CCF) characteristics among AC power sources. The methodology suggested in the present report is believed to be very useful in evaluating the SBO frequency and the core damage frequency resulting from the SBO event. This approach is also applicable to the probabilistic evaluation of the other shared systems in a multi-unit nuclear power plant

  8. Summary of the Current Status of Lessons Learned From Fukushima Accident

    International Nuclear Information System (INIS)

    Pasamehmetoglu, Kemal

    2013-01-01

    This presentation introduced the current status of the lessons learned from the Fukushima accident, and in particular, the recommendations released by a NRC Near-term Task Force to enhance reactor safety in the 21. century. The near-term recommendations are focused on emergency power and emergency cooling availability during station blackout accidents

  9. Association of Exposure to Radio-Frequency Electromagnetic Field Radiation (RF-EMFR Generated by Mobile Phone Base Stations with Glycated Hemoglobin (HbA1c and Risk of Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Sultan Ayoub Meo

    2015-11-01

    Full Text Available Installation of mobile phone base stations in residential areas has initiated public debate about possible adverse effects on human health. This study aimed to determine the association of exposure to radio frequency electromagnetic field radiation (RF-EMFR generated by mobile phone base stations with glycated hemoglobin (HbA1c and occurrence of type 2 diabetes mellitus. For this study, two different elementary schools (school-1 and school-2 were selected. We recruited 159 students in total; 96 male students from school-1, with age range 12–16 years, and 63 male students with age range 12–17 years from school-2. Mobile phone base stations with towers existed about 200 m away from the school buildings. RF-EMFR was measured inside both schools. In school-1, RF-EMFR was 9.601 nW/cm2 at frequency of 925 MHz, and students had been exposed to RF-EMFR for a duration of 6 h daily, five days in a week. In school-2, RF-EMFR was 1.909 nW/cm2 at frequency of 925 MHz and students had been exposed for 6 h daily, five days in a week. 5–6 mL blood was collected from all the students and HbA1c was measured by using a Dimension Xpand Plus Integrated Chemistry System, Siemens. The mean HbA1c for the students who were exposed to high RF-EMFR was significantly higher (5.44 ± 0.22 than the mean HbA1c for the students who were exposed to low RF-EMFR (5.32 ± 0.34 (p = 0.007. Moreover, students who were exposed to high RF-EMFR generated by MPBS had a significantly higher risk of type 2 diabetes mellitus (p = 0.016 relative to their counterparts who were exposed to low RF-EMFR. It is concluded that exposure to high RF-EMFR generated by MPBS is associated with elevated levels of HbA1c and risk of type 2 diabetes mellitus.

  10. Seasonal variation of seismic ambient noise level at King Sejong Station, Antarctica

    Science.gov (United States)

    Lee, W.; Sheen, D.; Seo, K.; Yun, S.

    2009-12-01

    The generation of the secondary- or double-frequency (DF) microseisms with dominant frequencies between 0.1 and 0.5 Hz has been explained by nonlinear second-order pressure perturbations on the ocean bottom due to the interference of two ocean waves of equal wavelengths traveling in opposite directions. Korea Polar Research Institute (KOPRI) has been operating a broadband seismic station (KSJ1) at King George Island (KGI), Antarctica, since 2001. Examining the ambient seismic noise level for the period from 2006 to 2008 at KSJ1, we found a significant seasonal variation in the frequency range 0.1-0.5 Hz. Correlation of the DF peaks with significant ocean wave height and peak wave period models indicates that the oceanic infragravity waves in the Drake Passage is a possible source to excite the DF microseisms at KGI. Location of King Sejong Station, Antarctica Seasonal variations of DF peak, significant wave height, and peak wave period

  11. Streamflow characteristics at hydrologic bench-mark stations

    Science.gov (United States)

    Lawrence, C.L.

    1987-01-01

    The Hydrologic Bench-Mark Network was established in the 1960's. Its objectives were to document the hydrologic characteristics of representative undeveloped watersheds nationwide and to provide a comparative base for studying the effects of man on the hydrologic environment. The network, which consists of 57 streamflow gaging stations and one lake-stage station in 39 States, is planned for permanent operation. This interim report describes streamflow characteristics at each bench-mark site and identifies time trends in annual streamflow that have occurred during the data-collection period. The streamflow characteristics presented for each streamflow station are (1) flood and low-flow frequencies, (2) flow duration, (3) annual mean flow, and (4) the serial correlation coefficient for annual mean discharge. In addition, Kendall's tau is computed as an indicator of time trend in annual discharges. The period of record for most stations was 13 to 17 years, although several stations had longer periods of record. The longest period was 65 years for Merced River near Yosemite, Calif. Records of flow at 6 of 57 streamflow sites in the network showed a statistically significant change in annual mean discharge over the period of record, based on computations of Kendall's tau. The values of Kendall's tau ranged from -0.533 to 0.648. An examination of climatological records showed that changes in precipitation were most likely the cause for the change in annual mean discharge.

  12. Tests of Shaft Seal Systems of Circulation Pumps during Station Blackout

    Energy Technology Data Exchange (ETDEWEB)

    Beisiegel, A.; Foppe, F.; Wich, M.

    2014-07-01

    AREVA GmbH operates a unique Thermal-hydraulic plat form in Germany, France and USA. It is recognised as a test body according to ISO 17025. The Deutsche Akkreditierungsstelle GmbH (DAkkS - German Society for Accreditation) has also certified the Thermal-hydraulic platform as an independent inspection body Type C according to ISO 17020. A part of this platform is the Component Laboratory located in Karlstein, Germany which is in operation since more than 50 years. The testing activities cover a wide range as: Critical Heat Flux Tests, Valve Testing and Environmental Qualification for safety related components. Since 2011 the Component Qualification Karlstein extended their testing scope for different types of Shaft Seal Systems. (Author)

  13. MANAGING A PROLONGED STATION BLACKOUT CONDITION IN AHWR BY PASSIVE MEANS

    Directory of Open Access Journals (Sweden)

    MUKESH KUMAR

    2013-10-01

    In view of this, an analysis has been performed for decay heat removal characteristics over several days of an AHWR by ICs. The computer code RELAP5/MOD3.2 was used for this purpose. Results indicate that the ICs can remove the decay heat for more than 10 days without causing any bulk boiling in the GDWP. After that, decay heat can be removed for more than 40 days by boiling off the pool inventory. The pressure inside the containment does not exceed the design pressure even after 10 days by condensation of steam generated from the GDWP on the walls of containment and on the Passive Containment Cooling System (PCCS tubes. If venting is carried out after this period, the decay heat can be removed for more than 50 days without exceeding the design limits.

  14. Analysis of time series exposure rates obtained at a monitoring station around nuclear power stations

    International Nuclear Information System (INIS)

    Urabe, I.; Ogawa, Y.; Kimura, Y.; Honda, Y.; Nakashima, Y.; Yoshimoto, T.; Tsujimoto, T.

    1991-01-01

    From the investigation on the variation of AAD rates monitored in the natural environment around nuclear power station, it may be concluded; (1) Differences between monthly averaged air absorbed dose rates (AAD rates) given by all data obtained and those obtained in fine weather become larger in winter (from Dec. to Feb.) (2) Cummulative frequency distributions of AAD rates are very different among four seasons. Remarkably high AAD rates are observed by heavy rains in summer and snow falls or rains in winter. (3) Though the hypothesis that the frequency distribution of AAD rates fit to the lognormal distribution can not be accepted by chi-square test, higher part of the frequency distribution of AAD rates agree approximately with the lognormal one. (4) Identification of AAD rates due to plume exposure may be possible by statistical analysis assuming lognormal distribution of AAD rates as well as the discrimination method based on the reference standard using mean values and standard deviations of the data obtained in fine weather. (author)

  15. Background noise model development for seismic stations of KMA

    Science.gov (United States)

    Jeon, Youngsoo

    2010-05-01

    The background noise recorded at seismometer is exist at any seismic signal due to the natural phenomena of the medium which the signal passed through. Reducing the seismic noise is very important to improve the data quality in seismic studies. But, the most important aspect of reducing seismic noise is to find the appropriate place before installing the seismometer. For this reason, NIMR(National Institution of Meteorological Researches) starts to develop a model of standard background noise for the broadband seismic stations of the KMA(Korea Meteorological Administration) using a continuous data set obtained from 13 broadband stations during the period of 2007 and 2008. We also developed the model using short period seismic data from 10 stations at the year of 2009. The method of Mcmara and Buland(2004) is applied to analyse background noise of Korean Peninsula. The fact that borehole seismometer records show low noise level at frequency range greater than 1 Hz compared with that of records at the surface indicate that the cultural noise of inland Korean Peninsula should be considered to process the seismic data set. Reducing Double Frequency peak also should be regarded because the Korean Peninsula surrounded by the seas from eastern, western and southern part. The development of KMA background model shows that the Peterson model(1993) is not applicable to fit the background noise signal generated from Korean Peninsula.

  16. Variations of the critical foE-frequency of the ionosphere connected with earthquakes. Evaluation of observations of the vertical sounding station "Tokyo"

    Science.gov (United States)

    Liperovskaya, Elena V.; Meister, Claudia-Veronika; Hoffmann, Dieter H. H.; Silina, Alexandra S.

    2016-04-01

    In the present work the critical frequencies foE and foF2 of the ionosphere are considered as possible earthquake precursors. The statistical analysis of the critical frequencies is carried out based on the data of the vertical sounding station (VSS) "Kokubunji" ("Tokyo") (ϕ = 35.7o N, λ = 139.5o E, 1957-1988) obtained every hour. Disturbances are considered on the background of seasonal, geomagnetic as well as 11-years and 27-days Solar variations. Special normalized parameters E and F are introduced, which represent the almost seasonal-independent parts of foE and foF2. Days with high Solar (Wolf number > 100) and geomagnetic (ΣKp > 25) activities are excluded from the analysis. For all data (observed every hour) analysed, no correlations of the normalized parameters E and F are found. One day before the seismic shock, a positive correlation is observed. The superimposed epochs method is used to determine the temporal behaviour of E and F. It is found that E and F decrease one day before the earthquakes provided that the seismic shocks occur at distances 600 5.5 is situated at depths smaller than 60 km. The reliability of the effect is larger than 98 %. Possible physical mechanisms of the phenomenon are discussed.

  17. LOFAR, the low frequency array

    Science.gov (United States)

    Vermeulen, R. C.

    2012-09-01

    LOFAR, the Low Frequency Array, is a next-generation radio telescope designed by ASTRON, with antenna stations concentrated in the north of the Netherlands and currently spread into Germany, France, Sweden and the United Kingdom; plans for more LOFAR stations exist in several other countries. Utilizing a novel, phased-array design, LOFAR is optimized for the largely unexplored low frequency range between 30 and 240 MHz. Digital beam-forming techniques make the LOFAR system agile and allow for rapid re-pointing of the telescopes as well as the potential for multiple simultaneous observations. Processing (e.g. cross-correlation) takes place in the LOFAR BlueGene/P supercomputer, and associated post-processing facilities. With its dense core (inner few km) array and long (more than 1000 km) interferometric baselines, LOFAR reaches unparalleled sensitivity and resolution in the low frequency radio regime. The International LOFAR Telescope (ILT) is now issuing its first call for observing projects that will be peer reviewed and selected for observing starting in December. Part of the allocations will be made on the basis of a fully Open Skies policy; there are also reserved fractions assigned by national consortia in return for contributions from their country to the ILT. In this invited talk, the gradually expanding complement of operationally verified observing modes and capabilities are reviewed, and some of the exciting first astronomical results are presented.

  18. Operational radio interferometry observation network (ORION) mobile VLBI station. [for NASA Crustal Dynamics Project

    Science.gov (United States)

    Renzetti, N. A.; Vegos, C. J.; Parks, G. S.; Sniffin, R. W.; Gannon, D. L.; Nishimura, H. G.; Clements, P. A.; Mckinney, R. P.; Menninger, F. J.; Vandenberg, N. R.

    1983-01-01

    The design and current status of the ORION mobile VLBI station is described. The station consists of a five-meter antenna, a receiving and recording system installed in a mobile antenna transporter, and an electronics transporter. The station is designed for field operation by a two-person crew at the rate of two sites per week. The various subsystems are described in detail, including the antenna, housing facilities for electronics and crew, microwave equipment, receiver, data acquisition subsystem, frequency and timing subsystem, phase calibration, monitoring and control, water vapor radiometer, and communications.

  19. The geomagnetic coast effect at two 80° S stations in Antarctica, observed in the ULF range

    Directory of Open Access Journals (Sweden)

    M. Regi

    2018-02-01

    Full Text Available We examined the coast effect in Antarctica along the 80° S magnetic parallel. We used the geomagnetic field measurements at the two coastal stations of Mario Zucchelli Station and Scott Base, and, as a reference, at the inland temporary station Talos Dome, during 18 January–14 March 2008. Spectral analysis in the Pc5 frequency range (1–7 mHz revealed large differences between coastal and inland stations, such as higher spectral power levels in the vertical component and higher coherence between horizontal and vertical components at coastal stations. Using the interstation method on selected active time intervals, with Talos Dome as a remote reference station, we found that remote reference induction arrows are directed almost perpendicularly with respect to their respective coastlines. Moreover, the single-station analysis shows that at Talos Dome the amplitude of the induction arrows is much smaller than at coastal stations. These results clearly indicate that coast effect at a few hundred kilometers from the coastline is relatively small. The coast effect on polarization parameters was examined, for a Pc5 event that occurred on 11 March 2008. The results evidenced that the azimuthal angle of polarized signals at one of the coastal stations is largely different with respect to the inland station (by  ∼  110°, while the polarization ratio and ellipticity attain comparable values. We proposed a correction method of the polarization parameters, which operates directly in the frequency domain, obtaining comparable azimuthal angles at coastal and inland stations.

  20. Low-frequency (0.7-7.4 mHz geomagnetic field fluctuations at high latitude: frequency dependence of the polarization pattern

    Directory of Open Access Journals (Sweden)

    L. Cafarella

    2001-06-01

    Full Text Available A statistical analysis of the polarization pattern of low-frequency geomagnetic field fluctuations (0.7-7.4 mHz covering the entire 24-h interval was performed at the Antarctic station Terra Nova Bay (80.0°S geomagnetic latitude throughout 1997 and 1998. The results show that the polarization pattern exhibits a frequency dependence, as can be expected from the frequency dependence of the latitude where the coupling between the magnetospheric compressional mode and the field line resonance takes place. The polarization analysis of single pulsation events shows that wave packets with different polarization sense, depending on frequency, can be simultaneously observed.

  1. Safety planning for nuclear power stations

    International Nuclear Information System (INIS)

    Tadmor, J.

    1979-01-01

    The article shows that compared to the many industries and other human activities, nuclear power stations are among the safest. A short description of the measures taken to prevent accidents and of the additional safety means entering into action if an accident does occur is presented. It is shown that in nuclear plants the death frequency following malfunctioning is 1 death in 100.000 years whereas deaths following other human activities is 1 in 2 to 100 years and following natural calamities like earthquakes and floods is 1 in 10 years. As an example it is shown that for a population of 15.000.000 living in a radius of 40 km around 100 power stations the average number of deaths will be of 2 per year as compared to 4200 from road accidents with the corresponding number of injuries of 20 and 375.000 respectively. (B.G.)

  2. A Probabilistic Model to Evaluate the Optimal Density of Stations Measuring Snowfall.

    Science.gov (United States)

    Schneebeli, Martin; Laternser, Martin

    2004-05-01

    Daily new snow measurements are very important for avalanche forecasting and tourism. A dense network of manual or automatic stations measuring snowfall is necessary to have spatially reliable data. Snow stations in Switzerland were built at partially subjective locations. A probabilistic model based on the frequency and spatial extent of areas covered by heavy snowfalls was developed to quantify the probability that snowfall events are measured by the stations. Area probability relations were calculated for different thresholds of daily accumulated snowfall. A probabilistic model, including autocorrelation, was used to calculate the optimal spacing of stations based on simulated triangular grids and to compare the capture probability of different networks and snowfall thresholds. The Swiss operational snow-stations network captured snowfall events with high probability, but the distribution of the stations could be optimized. The spatial variability increased with higher thresholds of daily accumulated snowfall, and the capture probability decreased with increasing thresholds. The method can be used for other areas where the area probability relation for threshold values of snow or rain can be calculated.

  3. Recent SCDAP/RELAP5 improvements for BWR severe accident simulations

    International Nuclear Information System (INIS)

    Griffin, F.P.

    1995-01-01

    A new model for the SCDAP/RELAP5 severe accident analysis code that represents the control blade and channel box structures in a boiling water reactor (BWR) has been under development since 1991. This model accounts for oxidation, melting, and relocation of these structures, including the effects of material interactions between B 4 C, stainless steel, and Zircaloy. This paper describes improvements that have been made to the BWR control blade/channel box model during 1994 and 1995. These improvements include new capabilities that represent the relocation of molten material in a more realistic manner and modifications that improve the usability of the code by reducing the frequency of code failures. This paper also describes a SCDAP/RELAP5 assessment calculation for the Browns Ferry Nuclear Plant design based upon a short-term station blackout accident sequence

  4. Draper Station Analysis Tool

    Science.gov (United States)

    Bedrossian, Nazareth; Jang, Jiann-Woei; McCants, Edward; Omohundro, Zachary; Ring, Tom; Templeton, Jeremy; Zoss, Jeremy; Wallace, Jonathan; Ziegler, Philip

    2011-01-01

    Draper Station Analysis Tool (DSAT) is a computer program, built on commercially available software, for simulating and analyzing complex dynamic systems. Heretofore used in designing and verifying guidance, navigation, and control systems of the International Space Station, DSAT has a modular architecture that lends itself to modification for application to spacecraft or terrestrial systems. DSAT consists of user-interface, data-structures, simulation-generation, analysis, plotting, documentation, and help components. DSAT automates the construction of simulations and the process of analysis. DSAT provides a graphical user interface (GUI), plus a Web-enabled interface, similar to the GUI, that enables a remotely located user to gain access to the full capabilities of DSAT via the Internet and Webbrowser software. Data structures are used to define the GUI, the Web-enabled interface, simulations, and analyses. Three data structures define the type of analysis to be performed: closed-loop simulation, frequency response, and/or stability margins. DSAT can be executed on almost any workstation, desktop, or laptop computer. DSAT provides better than an order of magnitude improvement in cost, schedule, and risk assessment for simulation based design and verification of complex dynamic systems.

  5. GPS data processing of networks with mixed single- and dual-frequency receivers for deformation monitoring

    Science.gov (United States)

    Zou, X.; Deng, Z.; Ge, M.; Dick, G.; Jiang, W.; Liu, J.

    2010-07-01

    In order to obtain crustal deformations of higher spatial resolution, existing GPS networks must be densified. This densification can be carried out using single-frequency receivers at moderate costs. However, ionospheric delay handling is required in the data processing. We adapt the Satellite-specific Epoch-differenced Ionospheric Delay model (SEID) for GPS networks with mixed single- and dual-frequency receivers. The SEID model is modified to utilize the observations from the three nearest dual-frequency reference stations in order to avoid contaminations from more remote stations. As data of only three stations are used, an efficient missing data constructing approach with polynomial fitting is implemented to minimize data losses. Data from large scale reference networks extended with single-frequency receivers can now be processed, based on the adapted SEID model. A new data processing scheme is developed in order to make use of existing GPS data processing software packages without any modifications. This processing scheme is evaluated using a sub-network of the German SAPOS network. The results verify that the new scheme provides an efficient way to densify existing GPS networks with single-frequency receivers.

  6. Frequency Analysis Using Bootstrap Method and SIR Algorithm for Prevention of Natural Disasters

    Science.gov (United States)

    Kim, T.; Kim, Y. S.

    2017-12-01

    The frequency analysis of hydrometeorological data is one of the most important factors in response to natural disaster damage, and design standards for a disaster prevention facilities. In case of frequency analysis of hydrometeorological data, it assumes that observation data have statistical stationarity, and a parametric method considering the parameter of probability distribution is applied. For a parametric method, it is necessary to sufficiently collect reliable data; however, snowfall observations are needed to compensate for insufficient data in Korea, because of reducing the number of days for snowfall observations and mean maximum daily snowfall depth due to climate change. In this study, we conducted the frequency analysis for snowfall using the Bootstrap method and SIR algorithm which are the resampling methods that can overcome the problems of insufficient data. For the 58 meteorological stations distributed evenly in Korea, the probability of snowfall depth was estimated by non-parametric frequency analysis using the maximum daily snowfall depth data. The results show that probabilistic daily snowfall depth by frequency analysis is decreased at most stations, and most stations representing the rate of change were found to be consistent in both parametric and non-parametric frequency analysis. This study shows that the resampling methods can do the frequency analysis of the snowfall depth that has insufficient observed samples, which can be applied to interpretation of other natural disasters such as summer typhoons with seasonal characteristics. Acknowledgment.This research was supported by a grant(MPSS-NH-2015-79) from Disaster Prediction and Mitigation Technology Development Program funded by Korean Ministry of Public Safety and Security(MPSS).

  7. Frequency modulator. Transmission of meteorological signals in LVC

    International Nuclear Information System (INIS)

    Rivero G, P.T.; Ramirez S, R.; Gonzalez M, J.L.; Rojas N, P.; Celis del Angel, L.

    2007-01-01

    The development of the frequency modulator and demodulator circuit for transmission of meteorological signals by means of fiber optics of the meteorology station to the nuclear reactor unit 1 in the Laguna Verde Central in Veracruz is described. (Author)

  8. Initiating events frequency determination

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; Vukovic, I.

    2004-01-01

    The paper describes work performed for the Nuclear Power Station (NPS). Work is related to the periodic initiating events frequency update for the Probabilistic Safety Assessment (PSA). Data for all relevant NPS initiating events (IE) were reviewed. The main focus was on events occurring during most recent operating history (i.e., last four years). The final IE frequencies were estimated by incorporating both NPS experience and nuclear industry experience. Each event was categorized according to NPS individual plant examination (IPE) initiating events grouping approach. For the majority of the IE groups, few, or no events have occurred at the NPS. For those IE groups with few or no NPS events, the final estimate was made by means of a Bayesian update with general nuclear industry values. Exceptions are rare loss-of-coolant-accidents (LOCA) events, where evaluation of engineering aspects is used in order to determine frequency.(author)

  9. Ionospheric correction for spaceborne single-frequency GPS based ...

    Indian Academy of Sciences (India)

    The Klobuchar model was used to compute ionospheric delays for the dlft station, and .... dual-frequency GPS receivers; therefore, the iono- ... The mapping function is defined as the ratio of .... eter in the processing of an extended set of single.

  10. Revisiting Frequency Reuse towards Supporting Ultra-Reliable Ubiquitous-Rate Communication

    DEFF Research Database (Denmark)

    Park, Jihong; Kim, Dong Min; Popovski, Petar

    2017-01-01

    One of the goals of 5G wireless systems stated by the NGMN alliance is to provide moderate rates (50+ Mbps) everywhere and with very high reliability. We term this service Ultra-Reliable Ubiquitous-Rate Communication (UR2C). This paper investigates the role of frequency reuse in supporting UR2C...... in the downlink. To this end, two frequency reuse schemes are considered: user-specific frequency reuse (FRu) and BS-specific frequency reuse (FRb). For a given unit frequency channel, FRu reduces the number of serving user equipments (UEs), whereas FRb directly decreases the number of interfering base stations...

  11. Solar dynamic power systems for space station

    Science.gov (United States)

    Irvine, Thomas B.; Nall, Marsha M.; Seidel, Robert C.

    1986-01-01

    The Parabolic Offset Linearly Actuated Reflector (POLAR) solar dynamic module was selected as the baseline design for a solar dynamic power system aboard the space station. The POLAR concept was chosen over other candidate designs after extensive trade studies. The primary advantages of the POLAR concept are the low mass moment of inertia of the module about the transverse boom and the compactness of the stowed module which enables packaging of two complete modules in the Shuttle orbiter payload bay. The fine pointing control system required for the solar dynamic module has been studied and initial results indicate that if disturbances from the station are allowed to back drive the rotary alpha joint, pointing errors caused by transient loads on the space station can be minimized. This would allow pointing controls to operate in bandwidths near system structural frequencies. The incorporation of the fine pointing control system into the solar dynamic module is fairly straightforward for the three strut concentrator support structure. However, results of structural analyses indicate that this three strut support is not optimum. Incorporation of a vernier pointing system into the proposed six strut support structure is being studied.

  12. Alcohol-Related Blackouts, Negative Alcohol-Related Consequences, and Motivations for Drinking Reported by Newly Matriculating Transgender College Students.

    Science.gov (United States)

    Tupler, Larry A; Zapp, Daniel; DeJong, William; Ali, Maryam; O'Rourke, Sarah; Looney, John; Swartzwelder, H Scott

    2017-05-01

    Many transgender college students struggle with identity formation and other emotional, social, and developmental challenges associated with emerging adulthood. A potential maladaptive coping strategy employed by such students is heavy drinking. Prior literature has suggested greater consumption and negative alcohol-related consequences (ARCs) in transgender students compared with their cisgender peers, but little is known about their differing experiences with alcohol-related blackouts (ARBs). We examined the level of alcohol consumption, the frequency of ARBs and other ARCs, and motivations for drinking reported by the largest sample of transgender college students to date. A Web survey from an alcohol-prevention program, AlcoholEdu for College™, assessed student demographics and drinking-related behaviors, experiences, and motivations of newly matriculating first-year college students. A self-reported drinking calendar was used to examine each of the following measures over the previous 14 days: number of drinking days, total number of drinks, and maximum number of drinks on any single day. A 7-point Likert scale was used to measure ARCs, ARBs, and drinking motivations. Transgender students of both sexes were compared with their cisgender peers. A total of 989 of 422,906 students (0.2%) identified as transgender. Over a 14-day period, transgender compared with cisgender students were more likely to consume alcohol over more days, more total drinks, and a greater number of maximum drinks on a single day. Transgender students (36%) were more likely to report an ARB than cisgender students (25%) as well as more negative academic, confrontation-related, social, and sexual ARCs. Transgender respondents more often cited stress reduction, social anxiety, self-esteem issues, and the inherent properties of alcohol as motivations for drinking. For nearly all measures, higher values were yielded by male-to-female than female-to-male transgender students. Transgender

  13. Biofouling in the condenser cooling conduits of Madras Atomic Power Station

    International Nuclear Information System (INIS)

    Thiyagarajan, V.; Subramoniam, T.; Venugopalan, V.P.; Nair, K.V.K.

    1995-01-01

    The present paper deals with various aspects fouling organisms collected from the condenser cooling water circuit of Madras Atomic Power Station (MAPS II) their biomass, thickness, composition and length frequency distribution of one of the major species namely, B. reticulatus. (author). 8 refs., 1 tab., 2 figs

  14. Influence of Plasma Pressure Fluctuation on RF Wave Propagation

    International Nuclear Information System (INIS)

    Liu Zhiwei; Bao Weimin; Li Xiaoping; Liu Donglin; Zhou Hui

    2016-01-01

    Pressure fluctuations in the plasma sheath from spacecraft reentry affect radio-frequency (RF) wave propagation. The influence of these fluctuations on wave propagation and wave properties is studied using methods derived by synthesizing the compressible turbulent flow theory, plasma theory, and electromagnetic wave theory. We study these influences on wave propagation at GPS and Ka frequencies during typical reentry by adopting stratified modeling. We analyzed the variations in reflection and transmission properties induced by pressure fluctuations. Our results show that, at the GPS frequency, if the waves are not totally reflected then the pressure fluctuations can remarkably affect reflection, transmission, and absorption properties. In extreme situations, the fluctuations can even cause blackout. At the Ka frequency, the influences are obvious when the waves are not totally transmitted. The influences are more pronounced at the GPS frequency than at the Ka frequency. This suggests that the latter can mitigate blackout by reducing both the reflection and the absorption of waves, as well as the influences of plasma fluctuations on wave propagation. Given that communication links with the reentry vehicles are susceptible to plasma pressure fluctuations, the influences on link budgets should be taken into consideration. (paper)

  15. Development of Radio Frequency Antenna Radiation Simulation Software

    International Nuclear Information System (INIS)

    Mohamad Idris Taib; Rozaimah Abd Rahim; Noor Ezati Shuib; Wan Saffiey Wan Abdullah

    2014-01-01

    Antennas are widely used national wide for radio frequency propagation especially for communication system. Radio frequency is electromagnetic spectrum from 10 kHz to 300 GHz and non-ionizing. These radiation exposures to human being have radiation hazard risk. This software was under development using LabVIEW for radio frequency exposure calculation. For the first phase of this development, software purposely to calculate possible maximum exposure for quick base station assessment, using prediction methods. This software also can be used for educational purpose. Some results of this software are comparing with commercial IXUS and free ware NEC software. (author)

  16. An empirical model of global spread-f occurrence

    International Nuclear Information System (INIS)

    Singleton, D.G.

    1974-09-01

    A method of combining models of ionospheric F-layer peak electron density and irregularity incremental electron density into a model of the occurrence probability of the frequency spreading component of spread-F is presented. The predictions of the model are compared with spread-F occurrence data obtained under sunspot maximum conditions. Good agreement is obtained for latitudes less than 70 0 geomagnetic. At higher latitudes, the inclusion of a 'blackout factor' in the model allows it to accurately represent the data and, in so doing, resolves an apparent discrepancy in the occurrence statistics at high latitudes. The blackout factor is ascribed to the effect of polar blackout on the spread-F statistics and/or the lack of a definitve incremental electron density model for irregularities at polar latitudes. Ways of isolating these effects and assessing their relative importance in the blackout factor are discussed. The model, besides providing estimates of spread-F occurrence on a worldwide basis, which will be of value in the engineering of HF and VHF communications, also furnishes a means of further checking the irregularity incremental electron density model on which it is based. (author)

  17. Scattering Effects of Solar Panels on Space Station Antenna Performance

    Science.gov (United States)

    Panneton, Robert J.; Ngo, John C.; Hwu, Shian U.; Johnson, Larry A.; Elmore, James D.; Lu, Ba P.; Kelley, James S.

    1994-01-01

    Characterizing the scattering properties of the solar array panels is important in predicting Space Station antenna performance. A series of far-field, near-field, and radar cross section (RCS) scattering measurements were performed at S-Band and Ku-Band microwave frequencies on Space Station solar array panels. Based on investigation of the measured scattering patterns, the solar array panels exhibit similar scattering properties to that of the same size aluminum or copper panel mockup. As a first order approximation, and for worse case interference simulation, the solar array panels may be modeled using perfect reflecting plates. Numerical results obtained using the Geometrical Theory of Diffraction (GTD) modeling technique are presented for Space Station antenna pattern degradation due to solar panel interference. The computational and experimental techniques presented in this paper are applicable for antennas mounted on other platforms such as ship, aircraft, satellite, and space or land vehicle.

  18. A Technical Approach to the Evaluation of Radiofrequency Radiation Emissions from Mobile Telephony Base Stations

    Directory of Open Access Journals (Sweden)

    Raimondas Buckus

    2017-03-01

    Full Text Available During the last two decades, the number of macrocell mobile telephony base station antennas emitting radiofrequency (RF electromagnetic radiation (EMR in residential areas has increased significantly, and therefore much more attention is being paid to RF EMR and its effects on human health. Scientific field measurements of public exposure to RF EMR (specifically to radio frequency radiation from macrocell mobile telephony base station antennas and RF electromagnetic field (EMF intensity parameters in the environment are discussed in this article. The research methodology is applied according to the requirements of safety norms and Lithuanian Standards in English (LST EN. The article presents and analyses RF EMFs generated by mobile telephony base station antennas in areas accessible to the general public. Measurements of the RF electric field strength and RF EMF power density were conducted in the near- and far-fields of the mobile telephony base station antenna. Broadband and frequency-selective measurements were performed outside (on the roof and on the ground and in a residential area. The tests performed on the roof in front of the mobile telephony base station antennas in the near-field revealed the presence of a dynamic energy interaction within the antenna electric field, which changes rapidly with distance. The RF EMF power density values on the ground at distances of 50, 100, 200, 300, 400, and 500 m from the base station are very low and are scattered within intervals of 0.002 to 0.05 μW/cm2. The results were compared with international exposure guidelines (ICNIRP.

  19. A Technical Approach to the Evaluation of Radiofrequency Radiation Emissions from Mobile Telephony Base Stations.

    Science.gov (United States)

    Buckus, Raimondas; Strukčinskienė, Birute; Raistenskis, Juozas; Stukas, Rimantas; Šidlauskienė, Aurelija; Čerkauskienė, Rimantė; Isopescu, Dorina Nicolina; Stabryla, Jan; Cretescu, Igor

    2017-03-01

    During the last two decades, the number of macrocell mobile telephony base station antennas emitting radiofrequency (RF) electromagnetic radiation (EMR) in residential areas has increased significantly, and therefore much more attention is being paid to RF EMR and its effects on human health. Scientific field measurements of public exposure to RF EMR (specifically to radio frequency radiation) from macrocell mobile telephony base station antennas and RF electromagnetic field (EMF) intensity parameters in the environment are discussed in this article. The research methodology is applied according to the requirements of safety norms and Lithuanian Standards in English (LST EN). The article presents and analyses RF EMFs generated by mobile telephony base station antennas in areas accessible to the general public. Measurements of the RF electric field strength and RF EMF power density were conducted in the near- and far-fields of the mobile telephony base station antenna. Broadband and frequency-selective measurements were performed outside (on the roof and on the ground) and in a residential area. The tests performed on the roof in front of the mobile telephony base station antennas in the near-field revealed the presence of a dynamic energy interaction within the antenna electric field, which changes rapidly with distance. The RF EMF power density values on the ground at distances of 50, 100, 200, 300, 400, and 500 m from the base station are very low and are scattered within intervals of 0.002 to 0.05 μW/cm². The results were compared with international exposure guidelines (ICNIRP).

  20. A Technical Approach to the Evaluation of Radiofrequency Radiation Emissions from Mobile Telephony Base Stations

    OpenAIRE

    Buckus, Raimondas; Struk?inskien?, Birute; Raistenskis, Juozas; Stukas, Rimantas; ?idlauskien?, Aurelija; ?erkauskien?, Rimant?; Isopescu, Dorina Nicolina; Stabryla, Jan; Cretescu, Igor

    2017-01-01

    During the last two decades, the number of macrocell mobile telephony base station antennas emitting radiofrequency (RF) electromagnetic radiation (EMR) in residential areas has increased significantly, and therefore much more attention is being paid to RF EMR and its effects on human health. Scientific field measurements of public exposure to RF EMR (specifically to radio frequency radiation) from macrocell mobile telephony base station antennas and RF electromagnetic field (EMF) intensity p...

  1. Influence of wind turbines on seismic stations in the upper rhine graben, SW Germany

    Science.gov (United States)

    Zieger, Toni; Ritter, Joachim R. R.

    2018-01-01

    By analysing long- and short-term seismological measurements at wind farms close to the town of Landau, SW Germany, we present new insights into ground motion signals from wind turbines (WTs) at local seismic stations. Because of their need to be located in similar regions with sparsely anthropogenic activities, wind turbines impact seismic stations and their recordings in a way that is not yet fully understood by researchers. To ensure the undisturbed recording tasks of a regional seismic array or a single station by a protected area around those endangered stations, it is very important to investigate the behavior of WTs as a seismic source. For that reason, we calculate averaged one-hour long spectra of the power spectral density (PSD) before and after the installation of a new wind farm within the investigated area. These PSD are ordered according to the rotation speed. We observe a clear increase of the PSD level after the WT installation in a frequency range of 0.5 to 10 Hz up to a distance of 5.5 km away from the WT. By analysing seismic borehole data, we also observe a decrease of the PSD of wind dependent signals with depth. The impact of wind-dependent signals is found to be much more pronounced for the shallower station (150 m depth) than for the deeper one (305 m depth). Using short-term profile measurements, we fit a power-law decay proportional to 1/ r b to the main WT-induced PSD peaks and differentiate between near-field and far-field effects of ground motions. For low frequencies in the range from 1 to 4 Hz, we determine a b value of 0.78 to 0.85 for the far field, which is consistent with surface waves. The b value increases (up to 1.59) with increasing frequencies (up to 5.5 Hz), which is obviously due to attenuating effects like scattering or anelasticity. These results give a better understanding of the seismic wavefield interactions between wind turbines (or wind farms) with nearby seismic stations, including borehole installations, in a

  2. Human reliability analysis for venting a BWR Mark I during a severe accident

    International Nuclear Information System (INIS)

    Nelson, W.R.; Blackman, H.S.

    1986-01-01

    A Human Reliability Analysis (HRA) was performed for the operator actions necessary to achieve containment venting for the Peach Bottom Atomic Power Station. This study was funded by the United States Nuclear Regulatory Commission (USNRC) and performed by the Idaho National Engineering Laboratory (INEL). The goal of the analysis was to estimate Human Error Probabilities (HEPs) to determine the likelihood that operators would fail to complete the venting process. The analysis was performed for two generic accident sequences: anticipated transient without scram (ATWS) and station blackout. Two major methods were used to estimate the HEPs: Technique for Human Error rate Prediction (THERP) and Success Likelihood Index Methodology (SLIM). For the ATWS scenarios analyzed, the calculated HEPs ranged from 0.23 to 0.35, depending on the number of vent paths that are required to reduce the containment pressure. It should be noted that the confidence bounds around these HEPs are large, However, even when considering the large confidence range, the failure probabilities are larger than what is typical for normal operator actions. For station blackout, the HEP is 1.0, resulting from the dangerous environmental conditions that are present, assuming that plant management would not deliberately expose personnel to a potentially fatal environment. These results are based on the analysis of draft procedures for containment venting. It is probable that careful revision of the procedures could reduce the human error probabilities

  3. A comprehensive analysis of physiologically equivalent temperature changes of Iranian selected stations for the last half century

    Science.gov (United States)

    Roshan, Gholamreza; Yousefi, Robabe; Kovács, Attila; Matzarakis, Andreas

    2018-01-01

    As a preliminary and major step for land use planning of the coming years, the study of variability of the past decades' climatic conditions with comprehensive indicators is of high importance. Given the fact that one of the affected areas by climatic change includes variability of thermal comfort, this study uses the physiologically equivalent temperature (PET) to identify and evaluate bioclimatic conditions of 40 meteorological stations in Iran. In this study, PET changes for the period of 1960 to 2010 are analyzed, with the use of Mann-Kendall non-parametric test and Pearson parametric method. The study focuses particularly on the diversity in spatio-temporal distribution of Iran's bioclimatic conditions. The findings show that the mean frequency percentage of days with comfort is 12.9 % according to the total number of selected stations. The maximum and minimum frequency percentage with values of 17.4 and 10.3 belong to Kerman and Chabahar stations, respectively. The findings of long-term trend analysis for the period of 1960-2010 show that 55 % of the stations have significant increasing trend in terms of thermal comfort class based on the Pearson method, while it is 40 % based on Mann-Kendall test. The results indicate that the highest frequency of days with thermal comfort in the southern coasts of Iran relates to the end of autumn and winter, nevertheless, such ideal conditions for the coastal cities of Caspian Sea and even central stations of Iran relate to mid-spring and mid-autumn. Late summer and early autumn along with late spring can be identified as the most ideal times in the west and northwest part of Iran. In addition, the most important inhibiting factors of thermal comfort prove to be different across the regions of Iran. For instance, in the southern coasts, warm to very hot bioclimatic events and in the west and northwest regions, cold to very cold conditions turn out to be the most important inhibiting factors. When considering the variations

  4. On Dimensions of OTA Setups for Massive MIMO Base Stations Radiated Testing

    DEFF Research Database (Denmark)

    Kyösti, Pekka; Fan, Wei; Pedersen, Gert F.

    2016-01-01

    The development of base stations (BS) with large aperture antenna arrays, enabled partially by the utilization of cmWave and mmWave frequency bands, will require radiated testing in fading conditions. In this paper, the objective is to investigate the suitable measurement distances and physical...

  5. 47 CFR 73.809 - Interference protection to full service FM stations.

    Science.gov (United States)

    2010-10-01

    ... radiation of radio frequency energy outside its assigned channel. Upon notice by the FCC to the station... efficacy of remedial measures. (e) In each instance where suspension of operation is required, the licensee shall submit a full report to the FCC in Washington, DC, after operation is resumed, containing details...

  6. Evaluation of a cavity flooding strategy for the prevention of reactor vessel failure in a severe accident

    Energy Technology Data Exchange (ETDEWEB)

    Park, Rae Joon; Je, Moo Sung; Park, Chang Kyoo [Korea Atomic Energy Research Institute, TaeJon (Korea, Republic of)

    1994-10-01

    As a part of the evaluation of accident management strategies for severe accident prevention or mitigation in a station blackout scenario for YGN 3 and 4, an external vessel cooling strategy for the prevention of reactor vessel failure has been estimated using the MAAP4 computer code. The sensitivity studies have been performed such as actuating timings and the number of spray pumps used. To explore external vessel cooling strategies, containment spray pumps were actuated by varying time spanning core uncovery, core melting and relocation of molten core material. It was shown that flooding of the reactor cavity using the containment spray system may prevent reactor vessel failure but may not prevent the failure of the relocation of molten core material during the station blackout sequence of YGN 3 and 4. Reactor vessel failure can be prevented by external vessel cooling using condensed water from the operation of two containment spray pumps at the time of core melting and using water from the operation of one containment spray pumps at the time of core melting and using water from the operation of one containment spray pump at the time of core uncovery. (Author) 46 refs., 26 figs., 5 tabs.

  7. Insights from the interim reliability evaluation program pertinent to reactor safety issues

    International Nuclear Information System (INIS)

    Carlson, D.D.

    1983-01-01

    The Interim Reliability Evaluation Program (IREP) consisted of concurrent probabilistic analyses of four operating nuclear power plants. This paper presents and integrated view of the results of the analyses drawing insights pertinent to reactor safety. The importance to risk of accident sequences initiated by transients and small loss-of-coolant accidents was confirmed. Support systems were found to contribute significantly to the sets of dominant accident sequences, either due to single failures which could disable one or more mitigating systems or due to their initiating plant transients. Human errors in response to accidents also were important risk contributors. Consideration of operator recovery actions influences accident sequence frequency estimates, the list of accident sequences dominating core melt, and the set of dominant risk contributors. Accidents involving station blackout, reactor coolant pump seal leaks and ruptures, and loss-of-coolant accidents requiring manual initiation of coolant injection were found to be risk significant

  8. Antenna unit and radio base station therewith

    Science.gov (United States)

    Kuwahara, Mikio; Doi, Nobukazu; Suzuki, Toshiro; Ishida, Yuji; Inoue, Takashi; Niida, Sumaru

    2007-04-10

    Phase and amplitude deviations, which are generated, for example, by cables connecting an array antenna of a CDMA base station and the base station, are calibrated in the baseband. The base station comprises: an antenna apparatus 1; couplers 2; an RF unit 3 that converts a receive signal to a baseband signal, converts a transmit signal to a radio frequency, and performs power control; an A/D converter 4 for converting a receive signal to a digital signal; a receive beam form unit 6 that multiplies the receive signal by semi-fixed weight; a despreader 7 for this signal input; a time-space demodulator 8 for demodulating user data; a despreader 9 for probe signal; a space modulator 14 for user data; a spreader 13 for user signal; a channel combiner 12; a Tx calibrater 11 for controlling calibration of a signal; a D/A converter 10; a unit 16 for calculation of correlation matrix for generating a probe signal used for controlling an Rx calibration system and a TX calibration system; a spreader 17 for probe signal; a power control unit 18; a D/A converter 19; an RF unit 20 for probe signal; an A/D converter 21 for signal from the couplers 2; and a despreader 22.

  9. Frequency Transient Suppression in Hybrid Electric Ship Power Systems: A Model Predictive Control Strategy for Converter Control with Energy Storage

    Directory of Open Access Journals (Sweden)

    Viknash Shagar

    2018-03-01

    Full Text Available This paper aims to understand how the common phenomenon of fluctuations in propulsion and service load demand contribute to frequency transients in hybrid electric ship power systems. These fluctuations arise mainly due to changes in sea conditions resulting in significant variations in the propulsion load demand of ships. This leads to poor power quality for the power system that can potentially cause hazardous conditions such as blackout on board the ship. Effects of these fluctuations are analysed using a hybrid electric ship power system model and a proposed Model Predictive Control (MPC strategy to prevent propagation of transients from the propellers into the shipboard power system. A battery energy storage system, which is directly connected to the DC-link of the frequency converter, is used as the smoothing element. Case studies that involve propulsion and service load changes have been carried out to investigate the efficacy of the proposed solution. Simulation results show that the proposed solution with energy storage and MPC is able to contain frequency transients in the shipboard power system within the permissible levels stipulated by the relevant power quality standards. These findings will help ship builders and operators to consider using battery energy storage systems controlled by advanced control techniques such as MPC to improve the power quality on board ships.

  10. Physically based method for measuring suspended-sediment concentration and grain size using multi-frequency arrays of acoustic-doppler profilers

    Science.gov (United States)

    Topping, David J.; Wright, Scott A.; Griffiths, Ronald; Dean, David

    2014-01-01

    As the result of a 12-year program of sediment-transport research and field testing on the Colorado River (6 stations in UT and AZ), Yampa River (2 stations in CO), Little Snake River (1 station in CO), Green River (1 station in CO and 2 stations in UT), and Rio Grande (2 stations in TX), we have developed a physically based method for measuring suspended-sediment concentration and grain size at 15-minute intervals using multifrequency arrays of acoustic-Doppler profilers. This multi-frequency method is able to achieve much higher accuracies than single-frequency acoustic methods because it allows removal of the influence of changes in grain size on acoustic backscatter. The method proceeds as follows. (1) Acoustic attenuation at each frequency is related to the concentration of silt and clay with a known grain-size distribution in a river cross section using physical samples and theory. (2) The combination of acoustic backscatter and attenuation at each frequency is uniquely related to the concentration of sand (with a known reference grain-size distribution) and the concentration of silt and clay (with a known reference grain-size distribution) in a river cross section using physical samples and theory. (3) Comparison of the suspended-sand concentrations measured at each frequency using this approach then allows theory-based calculation of the median grain size of the suspended sand and final correction of the suspended-sand concentration to compensate for the influence of changing grain size on backscatter. Although this method of measuring suspended-sediment concentration is somewhat less accurate than using conventional samplers in either the EDI or EWI methods, it is much more accurate than estimating suspended-sediment concentrations using calibrated pump measurements or single-frequency acoustics. Though the EDI and EWI methods provide the most accurate measurements of suspended-sediment concentration, these measurements are labor-intensive, expensive, and

  11. Hook whistlers observed at low latitude ground station Varanasi

    International Nuclear Information System (INIS)

    Khosa, P.N.; Lalmani; Ahmed, M.M.; Singh, B.D.

    1983-01-01

    Employing the Haselgrove ray tracing equations and a diffusive equilibrium model of the ionosphere, the propagation characteristics of hook whistlers recorded at low-latitude ground station Varanasi (geomag. lat., 16 0 6'N) are discussed. It is shown that the two traces of the hook whistlers are caused by the VLF waves radiated from the return stroke of a lightning discharge which after penetrating the ionosphere at two different entry points, propagated to the opposite hemisphere in the whistler mode and were received at 16 geomagnetic latitude. Further the crossing of ray paths for the same frequency leads to the explanation of the hook whistler. The lower and higher cut-off frequencies are explained in terms of their deviating away from the bunch of the recorded whistler waves and crossing of ray paths for the same frequency. (Auth.)

  12. International Space Station Future Correlation Analysis Improvements

    Science.gov (United States)

    Laible, Michael R.; Pinnamaneni, Murthy; Sugavanam, Sujatha; Grygier, Michael

    2018-01-01

    Ongoing modal analyses and model correlation are performed on different configurations of the International Space Station (ISS). These analyses utilize on-orbit dynamic measurements collected using four main ISS instrumentation systems: External Wireless Instrumentation System (EWIS), Internal Wireless Instrumentation System (IWIS), Space Acceleration Measurement System (SAMS), and Structural Dynamic Measurement System (SDMS). Remote Sensor Units (RSUs) are network relay stations that acquire flight data from sensors. Measured data is stored in the Remote Sensor Unit (RSU) until it receives a command to download data via RF to the Network Control Unit (NCU). Since each RSU has its own clock, it is necessary to synchronize measurements before analysis. Imprecise synchronization impacts analysis results. A study was performed to evaluate three different synchronization techniques: (i) measurements visually aligned to analytical time-response data using model comparison, (ii) Frequency Domain Decomposition (FDD), and (iii) lag from cross-correlation to align measurements. This paper presents the results of this study.

  13. Levels of electric field strength within the immediate vicinity of FM radio stations in Accra, Ghana.

    Science.gov (United States)

    Azah, C K; Amoako, J K; Fletcher, J J

    2013-10-01

    Heightened awareness of the ever-expanding use of radiofrequency (RF) techniques and technology has led to mounting concerns from the general public and the scientific community regarding the possible health effects that may arise as a consequence of exposure to RF radiations and has drawn the attention of many researchers the world over. A survey of the RF electromagnetic radiation at public access points in the vicinity of 20 frequency-modulated (FM) radio stations has been made in Accra, Ghana. The fundamental object was to determine the levels of RF fields from FM broadcast antennae within 10-200 m radius about the foot of the FM base station and at a height of 1.5 m above the ground at selected locations. A spectrum analyser and a bi-conical antenna element sensitive and effective within the frequency band of 30-300 MHz were used. Results obtained indicated that the levels of electric field strength ranged from 5.4E-04 V m(-1) at FM station 'O' to 7.4E-08 V m(-1) at FM station 'D'. At a transmission frequency range of 88-108 MHz, the variation of power densities is from 2.5E-10 to 1.5E-17 Wm(-2). These values are very low and are far below the reference level set by the International Commission on Non-Ionizing Radiation Protection and therefore do not pose any known hazard to the inhabitants of Accra, Ghana. The electric field levels presented in this work are comparable with those reported from epidemiological studies conducted elsewhere.

  14. Overview of the Nuclear Regulatory Commission's safety research program

    International Nuclear Information System (INIS)

    Beckjord, E.S.

    1989-01-01

    Accomplishments during 1988 of the Office of Nuclear Regulatory Research and the program of safety research are highlighted, and plans, expections, and needs of the next year and beyond are discussed. Topics discussed include: ECCS Appendix K Revision; pressurized thermal shock; NUREG-1150, or the PRA method performance document; resolution of station blackout; severe accident integration plan; nuclear safety research review committee; and program management

  15. 47 CFR 90.303 - Availability of frequencies.

    Science.gov (United States)

    2010-10-01

    ... table lists frequency bands that are available for assignment in specific urban areas. The available... available for use by eligibles in the Public Safety Radio Pool in the following areas: New York City; Nassau...)” curve in Figure B in 47 CFR 90.309(b). (ii) For base stations located west of the Hudson River, Kill Van...

  16. A review on the inter-frequency biases of GLONASS carrier-phase data

    Science.gov (United States)

    Geng, Jianghui; Zhao, Qile; Shi, Chuang; Liu, Jingnan

    2017-03-01

    GLONASS ambiguity resolution (AR) between inhomogeneous stations requires correction of inter-frequency phase biases (IFPBs) (a "station" here is an integral ensemble of a receiver, an antenna, firmware, etc.). It has been elucidated that IFPBs as a linear function of channel numbers are not physical in nature, but actually originate in differential code-phase biases (DCPBs). Although IFPBs have been prevalently recognized, an unanswered question is whether IFPBs and DCPBs are equivalent in enabling GLONASS AR. Besides, general strategies for the DCPB estimation across a large network of heterogeneous stations are still under investigation within the GNSS community, such as whether one DCPB per receiver type (rather than individual stations) suffices, as tentatively suggested by the IGS (International GNSS Service), and what accuracy we are able to and ought to achieve for DCPB products. In this study, we review the concept of DCPBs and point out that IFPBs are only approximate derivations from DCPBs, and are potentially problematic if carrier-phase hardware biases differ by up to several millimeters across frequency channels. We further stress the station and observable specific properties of DCPBs which cannot be thoughtlessly ignored as conducted conventionally. With 212 days of data from 200 European stations, we estimated DCPBs per stations by resolving ionosphere-free ambiguities of ˜ 5.3 cm wavelengths, and compared them to the presumed truth benchmarks computed directly with L1 and L2 data on ultra-short baselines. On average, the accuracy of our DCPB products is around 0.7 ns in RMS. According to this uncertainty estimates, we could unambiguously confirm that DCPBs can typically differ substantially by up to 30 ns among receivers of identical types and over 10 ns across different observables. In contrast, a DCPB error of more than 6 ns will decrease the fixing rate of ionosphere-free ambiguities by over 20 %, due to their smallest frequency spacing and

  17. A Bayesian analysis of trends in ozone sounding data series from 9 Nordic stations

    Science.gov (United States)

    Christiansen, Bo; Jepsen, Nis; Larsen, Niels; Korsholm, Ulrik S.

    2016-04-01

    Ozone soundings from 9 Nordic stations have been homogenized and interpolated to standard pressure levels. The different stations have very different data coverage; the longest period with data is from the end of the 1980ies to 2013. We apply a model which includes both low-frequency variability in form of a polynomial, an annual cycle with harmonics, the possibility for low-frequency variability in the annual amplitude and phasing, and either white noise or AR1 noise. The fitting of the parameters is performed with a Bayesian approach not only giving the posterior mean values but also credible intervals. We find that all stations agree on an well-defined annual cycle in the free troposphere with a relatively confined maximum in the early summer. Regarding the low-frequency variability we find that Scoresbysund, Ny Aalesund, and Sodankyla show similar structures with a maximum near 2005 followed by a decrease. However, these results are only weakly significant. A significant change in the amplitude of the annual cycle was only found for Ny Aalesund. Here the peak-to-peak amplitude changes from 0.9 to 0.8 mhPa between 1995-2000 and 2007-2012. The results are shown to be robust to the different settings of the model parameters (order of the polynomial, number of harmonics in the annual cycle, type of noise, etc). The results are also shown to be characteristic for all pressure levels in the free troposphere.

  18. Frequency domain analysis of the lightning current distribution to ground at the transmission line tower with cellular phone base station

    NARCIS (Netherlands)

    Grcev, L.; Deursen, van A.P.J.; Waes, van J.B.M.

    2003-01-01

    Cellular phone base stations are often placed in the poles of power transmission lines. We consider the case when such base stations are powered from the low-voltage network. Of special concern is the current that might be led through the cable metallic shields to other customers' premises in case

  19. Accuracy of Single Frequency GPS Observations Processing In Near Real-time With Use of Code Predicted Products

    Science.gov (United States)

    Wielgosz, P. A.

    In this year, the system of active geodetic GPS permanent stations is going to be estab- lished in Poland. This system should provide GPS observations for a wide spectrum of users, especially it will be a great opportunity for surveyors. Many of surveyors still use cheaper, single frequency receivers. This paper focuses on processing of single frequency GPS observations only. During processing of such observations the iono- sphere plays an important role, so we concentrated on the influence of the ionosphere on the positional coordinates. Twenty consecutive days of GPS data from 2001 year were processed to analyze the accuracy of a derived three-dimensional relative vec- tor position between GPS stations. Observations from two Polish EPN/IGS stations: BOGO and JOZE were used. In addition to, a new test station - IGIK was created. In this paper, the results of single frequency GPS observations processing in near real- time are presented. Baselines of 15, 27 and 42 kilometers and sessions of 1, 2, 3, 4, and 6 hours long were processed. While processing we used CODE (Centre for Orbit De- termination in Europe, Bern, Switzerland) predicted products: orbits and ionosphere info. These products are available in real-time and enable near real-time processing. Software Bernese v. 4.2 for Linux and BPE (Bernese Processing Engine) mode were used. These results are shown with a reference to dual frequency weekly solution (the best solution). Obtained GPS positional time and GPS baseline length dependency accuracy is presented for single frequency GPS observations.

  20. Centralized vs. Decentralized Nursing Stations: An Evaluation of the Implications of Communication Technologies in Healthcare.

    Science.gov (United States)

    Bayramzadeh, Sara; Alkazemi, Mariam F

    2014-01-01

    This study aims to explore the relationship between the nursing station design and use of communication technologies by comparing centralized and decentralized nursing stations. The rapid changes in communication technologies in healthcare are inevitable. Communication methods can change the way occupants use a space. In the meantime, decentralized nursing stations are emerging as a replacement for the traditional centralized nursing stations; however, not much research has been done on how the design of nursing stations can impact the use of communication technologies. A cross sectional study was conducted using an Internet-based survey among registered nurses in a Southeastern hospital in the United States. Two units with centralized nursing stations and two units with decentralized nursing stations were compared in terms of the application of communication technologies. A total of 70 registered nurses completed the survey in a 2-week period. The results revealed no significant differences between centralized and decentralized nursing stations in terms of frequency of communication technologies used. However, a difference was found between perception of nurses toward communication technologies and perceptions of the use of communication technologies in decentralized nursing stations. Although the study was limited to one hospital, the results indicate that nurses hold positive attitudes toward communication technologies. The results also reveal the strengths and weaknesses of each nursing station design with regard to communication technologies. Hospital, interdisciplinary, nursing, technology, work environment.

  1. Performance diagnostic system for emergency diesel generators

    International Nuclear Information System (INIS)

    Logan, K.P.

    1991-01-01

    Diesel generators are commonly used for emergency backup power at nuclear stations. Emergency diesel generators (EDGs) are subject to both start-up and operating failures, due to infrequent and fast-start use. EDG reliability can be critical to plant safety, particularly when station blackout occurs. This paper describes an expert diagnostic system designed to consistently evaluate the operating performance of diesel generators. The prototype system is comprised of a suite of sensor monitoring, cylinder combustion analyzing, and diagnostic workstation computers. On-demand assessments of generator and auxiliary equipment performance are provided along with color trend displays comparing measured performance to reference-normal conditions

  2. Nuclear station safety standardization from a risk concept

    International Nuclear Information System (INIS)

    Veksler, L.M.

    1986-01-01

    This paper presents a method of standardizing safety-system reliability on an entirely new basis: all hypothetical accidents are approximated as groups, for each of which one proposes permissible frequencies on the basis of the risk concept. In this risk concept, the ''average person'' is a person living near a nuclear station or working in it, who is of average age, average state of health, and so on. Therefore, the risk can be found by summing the estimated individual risks for a particular group in the population followed by division by the number of people in that group. Basic assumptions in deriving permissible safety-system reliability are presented. Estimated permissible failure probabilities are given to illustrate the proposed method and to refine the initial data. The probabilities may also be used to lay down the reliability requirements for safety systems in particular nuclear stations on the risk basis

  3. Use of regionalisation approach to develop fire frequency curves for Victoria, Australia

    Science.gov (United States)

    Khastagir, Anirban; Jayasuriya, Niranjali; Bhuyian, Muhammed A.

    2017-11-01

    It is important to perform fire frequency analysis to obtain fire frequency curves (FFC) based on fire intensity at different parts of Victoria. In this paper fire frequency curves (FFCs) were derived based on forest fire danger index (FFDI). FFDI is a measure related to fire initiation, spreading speed and containment difficulty. The mean temperature (T), relative humidity (RH) and areal extent of open water (LC2) during summer months (Dec-Feb) were identified as the most important parameters for assessing the risk of occurrence of bushfire. Based on these parameters, Andrews' curve equation was applied to 40 selected meteorological stations to identify homogenous stations to form unique clusters. A methodology using peak FFDI from cluster averaged FFDIs was developed by applying Log Pearson Type III (LPIII) distribution to generate FFCs. A total of nine homogeneous clusters across Victoria were identified, and subsequently their FFC's were developed in order to estimate the regionalised fire occurrence characteristics.

  4. Incorporating Nonstationarity into IDF Curves across CONUS from Station Records and Implications

    Science.gov (United States)

    Wang, K.; Lettenmaier, D. P.

    2017-12-01

    Intensity-duration-frequency (IDF) curves are widely used for engineering design of storm-affected structures. Current practice is that IDF-curves are based on observed precipitation extremes fit to a stationary probability distribution (e.g., the extreme value family). However, there is increasing evidence of nonstationarity in station records. We apply the Mann-Kendall trend test to over 1000 stations across the CONUS at a 0.05 significance level, and find that about 30% of stations test have significant nonstationarity for at least one duration (1-, 2-, 3-, 6-, 12-, 24-, and 48-hours). We fit the stations to a GEV distribution with time-varying location and scale parameters using a Bayesian- methodology and compare the fit of stationary versus nonstationary GEV distributions to observed precipitation extremes. Within our fitted nonstationary GEV distributions, we compare distributions with a time-varying location parameter versus distributions with both time-varying location and scale parameters. For distributions with two time-varying parameters, we pay particular attention to instances where location and scale trends have opposing directions. Finally, we use the mathematical framework based on work of Koutsoyiannis to generate IDF curves based on the fitted GEV distributions and discuss the implications that using time-varying parameters may have on simple scaling relationships. We apply the above methods to evaluate how frequency statistics based on a stationary assumption compare to those that incorporate nonstationarity for both short and long term projects. Overall, we find that neglecting nonstationarity can lead to under- or over-estimates (depending on the trend for the given duration and region) of important statistics such as the design storm.

  5. Statistical analysis of electromagnetic radiation measurements in the vicinity of GSM/UMTS base station antenna masts.

    Science.gov (United States)

    Koprivica, Mladen; Neskovic, Natasa; Neskovic, Aleksandar; Paunovic, George

    2014-01-01

    As a result of dense installations of public mobile base station, additional electromagnetic radiation occurs in the living environment. In order to determine the level of radio-frequency radiation generated by base stations, extensive electromagnetic field strength measurements were carried out for 664 base station locations. Base station locations were classified into three categories: indoor, masts and locations with installations on buildings. Having in mind the large percentage (47 %) of sites with antenna masts, a detailed analysis of this location category was performed, and the measurement results were presented. It was concluded that the total electric field strength in the vicinity of base station antenna masts in no case exceeded 10 V m(-1), which is quite below the International Commission on Non-Ionizing Radiation Protection reference levels. At horizontal distances >50 m from the mast bottom, the median and maximum values were <1 and 2 V m(-1), respectively.

  6. Statistical analysis of electromagnetic radiation measurements in the vicinity of GSM/UMTS base station antenna masts

    International Nuclear Information System (INIS)

    Koprivica, M.; Neskovic, N.; Neskovic, A.; Paunovic, G.

    2014-01-01

    As a result of dense installations of public mobile base station, additional electromagnetic radiation occurs in the living environment. In order to determine the level of radio-frequency radiation generated by base stations, extensive electromagnetic field strength measurements were carried out for 664 base station locations. Base station locations were classified into three categories: indoor, masts and locations with installations on buildings. Having in mind the large percentage (47 %) of sites with antenna masts, a detailed analysis of this location category was performed, and the measurement results were presented. It was concluded that the total electric field strength in the vicinity of base station antenna masts in no case exceeded 10 V m -1 , which is quite below the International Commission on Non-Ionizing Radiation Protection reference levels. At horizontal distances >50 m from the mast bottom, the median and maximum values were -1 , respectively. (authors)

  7. Non-Coop Station History

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Station history documentation for stations outside the US Cooperative Observer network. Primarily National Weather Service stations assigned WBAN station IDs. Other...

  8. Climate Informed Low Flow Frequency Analysis Using Nonstationary Modeling

    Science.gov (United States)

    Liu, D.; Guo, S.; Lian, Y.

    2014-12-01

    Stationarity is often assumed for frequency analysis of low flows in water resources management and planning. However, many studies have shown that flow characteristics, particularly the frequency spectrum of extreme hydrologic events,were modified by climate change and human activities and the conventional frequency analysis without considering the non-stationary characteristics may lead to costly design. The analysis presented in this paper was based on the more than 100 years of daily flow data from the Yichang gaging station 44 kilometers downstream of the Three Gorges Dam. The Mann-Kendall trend test under the scaling hypothesis showed that the annual low flows had significant monotonic trend, whereas an abrupt change point was identified in 1936 by the Pettitt test. The climate informed low flow frequency analysis and the divided and combined method are employed to account for the impacts from related climate variables and the nonstationarities in annual low flows. Without prior knowledge of the probability density function for the gaging station, six distribution functions including the Generalized Extreme Values (GEV), Pearson Type III, Gumbel, Gamma, Lognormal, and Weibull distributions have been tested to find the best fit, in which the local likelihood method is used to estimate the parameters. Analyses show that GEV had the best fit for the observed low flows. This study has also shown that the climate informed low flow frequency analysis is able to exploit the link between climate indices and low flows, which would account for the dynamic feature for reservoir management and provide more accurate and reliable designs for infrastructure and water supply.

  9. 47 CFR 80.107 - Service of private coast stations and marine-utility stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Service of private coast stations and marine...) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Operating Requirements and Procedures Operating Procedures-Land Stations § 80.107 Service of private coast stations and marine-utility stations. A...

  10. International Space Station Model Correlation Analysis

    Science.gov (United States)

    Laible, Michael R.; Fitzpatrick, Kristin; Hodge, Jennifer; Grygier, Michael

    2018-01-01

    This paper summarizes the on-orbit structural dynamic data and the related modal analysis, model validation and correlation performed for the International Space Station (ISS) configuration ISS Stage ULF7, 2015 Dedicated Thruster Firing (DTF). The objective of this analysis is to validate and correlate the analytical models used to calculate the ISS internal dynamic loads and compare the 2015 DTF with previous tests. During the ISS configurations under consideration, on-orbit dynamic measurements were collected using the three main ISS instrumentation systems; Internal Wireless Instrumentation System (IWIS), External Wireless Instrumentation System (EWIS) and the Structural Dynamic Measurement System (SDMS). The measurements were recorded during several nominal on-orbit DTF tests on August 18, 2015. Experimental modal analyses were performed on the measured data to extract modal parameters including frequency, damping, and mode shape information. Correlation and comparisons between test and analytical frequencies and mode shapes were performed to assess the accuracy of the analytical models for the configurations under consideration. These mode shapes were also compared to earlier tests. Based on the frequency comparisons, the accuracy of the mathematical models is assessed and model refinement recommendations are given. In particular, results of the first fundamental mode will be discussed, nonlinear results will be shown, and accelerometer placement will be assessed.

  11. 47 CFR 73.6016 - Digital Class A TV station protection of TV broadcast stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital Class A TV station protection of TV... Class A TV station protection of TV broadcast stations. Digital Class A TV stations must protect authorized TV broadcast stations, applications for minor changes in authorized TV broadcast stations filed on...

  12. Fire Stations

    Data.gov (United States)

    Department of Homeland Security — Fire Stations in the United States Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their...

  13. Do cities deserve more railway stations? The choice of a departure railway station in a multiple-station region

    NARCIS (Netherlands)

    Givoni, M.; Rietveld, P.

    2014-01-01

    Promoting the use of rail is an important element in sustainable transport policy. One of the most important decisions to make in planning the railway network is on the number of stations to provide. Stations are the access points to rail services and while each additional station increases rail's

  14. Study of risk reduction by improving operation of reactor core isolation cooling system

    International Nuclear Information System (INIS)

    Watanabe, Yamato; Tazai, Ayuko; Yamagishi, Shohei; Muramatsu, Ken; Muta, Hitoshi

    2014-01-01

    The Fukushima Daiichi nuclear power plant fell into a station blackout (SBO) due to the earthquake and tsunami in which most of the core cooling systems were disabled. In the units 2 and 3, water injection to the core was performed only by water injection system with turbine driven pumps. In particular, it is inferred from observed plant parameters that the reactor core isolation cooling system (RCIC) continued its operation much longer than it was originally expected (8 hours). Since the preparation of safety measures did not work, the reactor core damaged. With a view to reduce risk of station blackout events in a BWR by accident management, this study investigated the efficacy of operation procedures that takes advantage of RCIC which can be operated with only equipment inside reactor building and does not require an AC power source. The efficacy was assessed in this study by two steps. The first step is a thermal hydraulic analysis with the RETRAN3D code to estimate the potential extension of duration of core cooling by RCIC and the second step is the estimation of time required for recovery of off-site power from experiences at nuclear power stations under the 3.11 earthquake. This study showed that it is possible to implement more reliable measures for accident termination and to greatly reduce the risk of SBO by the installation of accident management measures with use of RCIC for extension of core cooling under SBO conditions. (author)

  15. 47 CFR 73.6018 - Digital Class A TV station protection of DTV stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital Class A TV station protection of DTV... TV station protection of DTV stations. Digital Class A TV stations must protect the DTV service that... application for digital operation of an existing Class A TV station or to change the facilities of a digital...

  16. Cascaded multiplexed optical link on a telecommunication network for frequency dissemination.

    Science.gov (United States)

    Lopez, Olivier; Haboucha, Adil; Kéfélian, Fabien; Jiang, Haifeng; Chanteau, Bruno; Roncin, Vincent; Chardonnet, Christian; Amy-Klein, Anne; Santarelli, Giorgio

    2010-08-02

    We demonstrate a cascaded optical link for ultrastable frequency dissemination comprised of two compensated links of 150 km and a repeater station. Each link includes 114 km of Internet fiber simultaneously carrying data traffic through a dense wavelength division multiplexing technology, and passes through two routing centers of the telecommunication network. The optical reference signal is inserted in and extracted from the communication network using bidirectional optical add-drop multiplexers. The repeater station operates autonomously ensuring noise compensation on the two links and the ultra-stable signal optical regeneration. The compensated link shows a fractional frequency instability of 3 x 10(-15) at one second measurement time and 5 x 10(-20) at 20 hours. This work paves the way to a wide dissemination of ultra-stable optical clock signals between distant laboratories via the Internet network.

  17. High-precision coseismic displacement estimation with a single-frequency GPS receiver

    Science.gov (United States)

    Guo, Bofeng; Zhang, Xiaohong; Ren, Xiaodong; Li, Xingxing

    2015-07-01

    To improve the performance of Global Positioning System (GPS) in the earthquake/tsunami early warning and rapid response applications, minimizing the blind zone and increasing the stability and accuracy of both the rapid source and rupture inversion, the density of existing GPS networks must be increased in the areas at risk. For economic reasons, low-cost single-frequency receivers would be preferable to make the sparse dual-frequency GPS networks denser. When using single-frequency GPS receivers, the main problem that must be solved is the ionospheric delay, which is a critical factor when determining accurate coseismic displacements. In this study, we introduce a modified Satellite-specific Epoch-differenced Ionospheric Delay (MSEID) model to compensate for the effect of ionospheric error on single-frequency GPS receivers. In the MSEID model, the time-differenced ionospheric delays observed from a regional dual-frequency GPS network to a common satellite are fitted to a plane rather than part of a sphere, and the parameters of this plane are determined by using the coordinates of the stations. When the parameters are known, time-differenced ionospheric delays for a single-frequency GPS receiver could be derived from the observations of those dual-frequency receivers. Using these ionospheric delay corrections, coseismic displacements of a single-frequency GPS receiver can be accurately calculated based on time-differenced carrier-phase measurements in real time. The performance of the proposed approach is validated using 5 Hz GPS data collected during the 2012 Nicoya Peninsula Earthquake (Mw 7.6, 2012 September 5) in Costa Rica. This shows that the proposed approach improves the accuracy of the displacement of a single-frequency GPS station, and coseismic displacements with an accuracy of a few centimetres are achieved over a 10-min interval.

  18. From city’s station to station city. An integrative spatial approach to the (redevelopment of station areas

    Directory of Open Access Journals (Sweden)

    Ana Luísa Martins da Conceição

    2014-12-01

    Full Text Available Since its origin, the railway station has had a complicated relationship with the city, demanding periodical updates, particularly regarding spatial issues. With the aim of improving the liveability of station areas, current redevelopment projects are reconceptualising them as balanced transport ‘nodes’ and ‘places’ in the city. However, the proposed spatial solutions do not fully support the sought after economic, social and environmental performances. These intentions continue to be predominantly bounded with the (abstract planological level, not finding appropriate translation at the (concrete spatial design level. Further, the interdisciplinary nature of the highly complex planning and design processes of station areas, which should contribute to enhance the performance of their spaces, reinforces constraints and relegates architecture to a marginal role in this quest. It is thus necessary to understand how architecture can contribute to the improvement of the spatial performance of contemporary stations areas, supporting their current reconceptualization. To gain this understanding, the research explored the factors which influence the spatial definition and performance of European High Speed Train station areas, using “design research” and “research by design”. Via a theoretical integrative framework, synthesized from knowledge developed by architecture and other sciences, case studies of ‘through’ stations were analysed and compared. Six cases, encapsulating the most recurrent relative positions of the railway (infrastructure and the station building towards the(ir direct built environment, were chosen out of a large sample. For each category (cases with railway tracks at (a ground level, (b elevated level and (c underground level, two cases, featuring an adapted station building and a newly built one, were studied. Their physical and functional characteristics were mapped at several scales and moments (in history, as

  19. Sizewell 'dirty tricks'

    International Nuclear Information System (INIS)

    Martin, Steve.

    1987-01-01

    The pro-nuclear lobby is accused of dubious tactics to promote their case for the Sizewell-B reactor. These include reassessing future electricity demand which, it is claimed, could only be met by nuclear power, claiming that new power stations were needed to avoid blackouts during cold spells, and the reporting of a major design fault in the control rods of the Torness and Heysham AGR stations. The latter is felt to be related to the promotion by the South of Scotland Electricity Board of the AGR case, as opposed to the Central Electricity Generating Board's advocation of a PWR reactor design. The author argues for a series of coal-fired power stations instead, and a major energy conservation programme. (UK)

  20. Estimation of Flood-Frequency Discharges for Rural, Unregulated Streams in West Virginia

    Science.gov (United States)

    Wiley, Jeffrey B.; Atkins, John T.

    2010-01-01

    Flood-frequency discharges were determined for 290 streamgage stations having a minimum of 9 years of record in West Virginia and surrounding states through the 2006 or 2007 water year. No trend was determined in the annual peaks used to calculate the flood-frequency discharges. Multiple and simple least-squares regression equations for the 100-year (1-percent annual-occurrence probability) flood discharge with independent variables that describe the basin characteristics were developed for 290 streamgage stations in West Virginia and adjacent states. The regression residuals for the models were evaluated and used to define three regions of the State, designated as Eastern Panhandle, Central Mountains, and Western Plateaus. Exploratory data analysis procedures identified 44 streamgage stations that were excluded from the development of regression equations representative of rural, unregulated streams in West Virginia. Regional equations for the 1.1-, 1.5-, 2-, 5-, 10-, 25-, 50-, 100-, 200-, and 500-year flood discharges were determined by generalized least-squares regression using data from the remaining 246 streamgage stations. Drainage area was the only significant independent variable determined for all equations in all regions. Procedures developed to estimate flood-frequency discharges on ungaged streams were based on (1) regional equations and (2) drainage-area ratios between gaged and ungaged locations on the same stream. The procedures are applicable only to rural, unregulated streams within the boundaries of West Virginia that have drainage areas within the limits of the stations used to develop the regional equations (from 0.21 to 1,461 square miles in the Eastern Panhandle, from 0.10 to 1,619 square miles in the Central Mountains, and from 0.13 to 1,516 square miles in the Western Plateaus). The accuracy of the equations is quantified by measuring the average prediction error (from 21.7 to 56.3 percent) and equivalent years of record (from 2.0 to 70

  1. pH and its frequency distribution patterns of Acid Precipitation in Japan

    International Nuclear Information System (INIS)

    Kitamura, Moritsugu; Katou, Takunori; Sekiguchi, Kyoichi

    1991-01-01

    The pH data was collected at the 29 stations in Phase-I study of Acid Precipitation Survey over Japan by Japan Environment Agency in terms of frequency distribution patterns. This study was undertaken from April 1984 to March 1988, which was the first survey of acid precipitation over Japan with identical sampling procedures and subsequent chemical analyses. While the annual mean pH at each station ranged from 4.4 to 5.5, the monthly mean varied more widely, from 4.0 to 7.1. Its frequency distribution pattern was obtained for each station, and further grouped into four classes: class I; a mode at the rank of pH 4.5∼4.9, class II; bimodes above and below this pH region, class III; a mode at a higher pH region, class IV; a mode at a lower pH region. The bimodal pattern was suggestive of precipitation with and without incorporation of significant amounts of basic aerosol of anthropogenic origin during descent of rain droplet. The patterns of the stations were also classified on a basis of summer-winter difference into another four classes. Winter pH values were appreciably lower than summer pHs in western parts of Japan and on Japan Sea coast, we attribute the winter pH to probable contribution of acidic pollutants transported by strong winter monsoon from Eurasian Continent. At most stations in northern and eastern Japan, the pH was higher in winter months reflecting more incorporation of basic materials, e.g., NH 4 + and Ca 2+ . (author)

  2. On measuring surface wave phase velocity from station–station cross-correlation of ambient signal

    DEFF Research Database (Denmark)

    Boschi, Lapo; Weemstra, Cornelis; Verbeke, Julie

    2012-01-01

    We apply two different algorithms to measure surface wave phase velocity, as a function of frequency, from seismic ambient noise recorded at pairs of stations from a large European network. The two methods are based on consistent theoretical formulations, but differ in the implementation: one met...

  3. Investigation on accident management measures for VVER-1000 reactors

    International Nuclear Information System (INIS)

    Tusheva, P.; Schaefer, F.; Rohde, U.; Reinke, N.

    2009-01-01

    A consequence of a total loss of AC power supply (station blackout) leading to unavailability of major active safety systems which could not perform their safety functions is that the safety criteria ensuring a secure operation of the nuclear power plant would be violated and a consequent core heat-up with possible core degradation would occur. Currently, a study which examines the thermal-hydraulic behaviour of the plant during the early phase of the scenario is being performed. This paper focuses on the possibilities for delay or mitigation of the accident sequence to progress into a severe one by applying Accident Management Measures (AMM). The strategy 'Primary circuit depressurization' as a basic strategy, which is realized in the management of severe accidents is being investigated. By reducing the load over the vessel under severe accident conditions, prerequisites for maintaining the integrity of the primary circuit are being created. The time-margins for operators' intervention as key issues are being also assessed. The task is accomplished by applying the GRS thermal-hydraulic system code ATHLET. In addition, a comparative analysis of the accident progression for a station blackout event for both a reference German PWR and a reference VVER-1000, taking into account the plant specifics, is being performed. (authors)

  4. Feasibility of future epidemiological studies on possible health effects of mobile phone base stations.

    Science.gov (United States)

    Neubauer, Georg; Feychting, Maria; Hamnerius, Yngve; Kheifets, Leeka; Kuster, Niels; Ruiz, Ignacio; Schüz, Joachim; Uberbacher, Richard; Wiart, Joe; Röösli, Martin

    2007-04-01

    The increasing deployment of mobile communication base stations led to an increasing demand for epidemiological studies on possible health effects of radio frequency emissions. The methodological challenges of such studies have been critically evaluated by a panel of scientists in the fields of radiofrequency engineering/dosimetry and epidemiology. Strengths and weaknesses of previous studies have been identified. Dosimetric concepts and crucial aspects in exposure assessment were evaluated in terms of epidemiological studies on different types of outcomes. We conclude that in principle base station epidemiological studies are feasible. However, the exposure contributions from all relevant radio frequency sources have to be taken into account. The applied exposure assessment method should be piloted and validated. Short to medium term effects on physiology or health related quality of life are best investigated by cohort studies. For long term effects, groups with a potential for high exposure need to first be identified; for immediate effect, human laboratory studies are the preferred approach. (c) 2006 Wiley-Liss, Inc.

  5. Enhancing Network Quality using Baseband Frequency Hopping, Downlink Power Control and DTX in a Live GSM Network

    DEFF Research Database (Denmark)

    Nielsen, Thomas Toftegaard; Wagard, Jeroen; Skjærris, Søren

    1998-01-01

    Baseband frequency hopping in the combination with downlink power control and discontinuous transmission has been investigated as a quality improving feature in a live GSM network. Using the dropped call rate and the frame erasure rate to measure the network quality, the use of frequency hopping...... to the statistical inaccuracy with discontinuous transmission in GSM and maybe due to poor performance of the mobile stations, was encountered. The current status is therefore to reject the use of downlink discontinuous transmission until more information about the performance of the mobile stations is found...

  6. Alcohol-related blackouts among college students: impact of low level of response to alcohol, ethnicity, sex, and environmental characteristics

    Directory of Open Access Journals (Sweden)

    Priscila D. Gonçalves

    2017-08-01

    Full Text Available Objective: To explore how a genetically-influenced characteristic (the level of response to alcohol [LR], ethnicity, and sex relate to environmental and attitudinal characteristics (peer drinking [PEER], drinking to cope [COPE], and alcohol expectancies [EXPECT] regarding future alcohol-related blackouts (ARBs. Methods: Structural equation models (SEMs were used to evaluate how baseline variables related to ARB patterns in 462 college students over 55 weeks. Data were extracted from a longitudinal study of heavy drinking and its consequences at a U.S. university. Results: In the SEM analysis, female sex and Asian ethnicity directly predicted future ARBs (beta weights 0.10 and -0.11, respectively, while all other variables had indirect impacts on ARBs through alcohol quantities (beta weights ~ 0.23 for European American ethnicity and low LR, 0.21 for cannabis use and COPE, and 0.44 for PEER. Alcohol quantities then related to ARBs with beta = 0.44. The SEM explained 23% of the variance. Conclusion: These data may be useful in identifying college students who are more likely to experience future ARBs over a 1-year period. They enhance our understanding of whether the relationships of predictors to ARBs are direct or mediated through baseline drinking patterns, information that may be useful in prevention strategies for ARBs.

  7. Characteristics and seasonal variations of precipitation phenomena at Syowa Station

    Directory of Open Access Journals (Sweden)

    Hiroyuki Konishi

    1997-03-01

    Full Text Available Long-term observations of precipitating clouds were carried out by a vertical pointing radar, PPI radar and a 37 GHz microwave radiometer at Syowa Station (69°00′S, 39°35′E, Antarctica in 1989. It is concluded from the observations that precipitation near Syowa Station, Antarctica is mainly brought by cloud vortices associated with extratropical cyclones which advance to high latitude while developing to a mature stage. The seasonal variations of clouds and precipitation were analyzed corresponding to the seasonal changes of air temperature and sea ice area. The occurrence frequencies of cloud vortices which brought snowfall to Syowa Station increased in the fall and spring seasons corresponding to activity of the circumpolar trough. However, the activities of cloud systems that bring precipitation weaken in spring when the sea ice area expands to low latitudes, because of less supply of heat and vapor. In 1989,the amount of precipitation in spring brought by a few snowfall events was as large as the amount of precipitation in fall brought by frequent snowfall events. Radar observations revealed that there were three abundant snowfall seasons at Syowa Station and the amount of snowfall was uniform in all seasons except summer. The amounts of precipitation in fall, winter and spring were 74,74 and 53mm respectively.

  8. Estimating Pedestrian flows at train stations using the Station Transfer Model

    NARCIS (Netherlands)

    Van den Heuvel, J.P.A.; Dekkers, K.; De Vos, S.

    2012-01-01

    Train stations play a vital role in the door to door travel experience of train passengers. From the passengers’ value of time perspective, the station is the weakest link in total time value of the journey. Within the station the transfer function – moving between the various transport modes and

  9. The Skipheia Wind Measurement Station. Instrumentation, Wind Speed Profiles and Turbulence Spectra

    Energy Technology Data Exchange (ETDEWEB)

    Aasen, S E

    1995-10-01

    This thesis describes the design of a measurement station for turbulent wind and presents results from an analysis of the collected data. The station is located at Skipheia near the south-west end of Froeya, an island off the coast of Mid-Norway. The station is unique for studies of turbulent winds because of the large numbers of sensors, which are located at various heights above ground up to 100 m, a sampling rate of 0.85 Hz and storage of the complete time series. The frequency of lightning and atmospheric discharges to the masts are quite high and much effort has gone into minimizing the damage caused by lightning activity. A major part of the thesis deals with data analysis and modelling. There are detailed discussions on the various types of wind sensors and their calibration, the data acquisition system and operating experiences with it, the database, data quality control, the wind speed profile and turbulence. 40 refs., 78 figs., 17 tabs.

  10. User manual of the CATSS system (version 1.0) communication analysis tool for space station

    Science.gov (United States)

    Tsang, C. S.; Su, Y. T.; Lindsey, W. C.

    1983-01-01

    The Communication Analysis Tool for the Space Station (CATSS) is a FORTRAN language software package capable of predicting the communications links performance for the Space Station (SS) communication and tracking (C & T) system. An interactive software package was currently developed to run on the DEC/VAX computers. The CATSS models and evaluates the various C & T links of the SS, which includes the modulation schemes such as Binary-Phase-Shift-Keying (BPSK), BPSK with Direct Sequence Spread Spectrum (PN/BPSK), and M-ary Frequency-Shift-Keying with Frequency Hopping (FH/MFSK). Optical Space Communication link is also included. CATSS is a C & T system engineering tool used to predict and analyze the system performance for different link environment. Identification of system weaknesses is achieved through evaluation of performance with varying system parameters. System tradeoff for different values of system parameters are made based on the performance prediction.

  11. Frequency Dependence of Measured Massive MIMO Channel Properties

    DEFF Research Database (Denmark)

    Oliveras Martínez, Àlex; Carvalho, Elisabeth De; Nielsen, Jesper Ødum

    2016-01-01

    A multi-user massive MIMO measurement campaign is conducted to study the channel propagation characteristics (e.g. user correlation, sum of eigenvalues and condition number), focusing on the stability over frequencies and the impact of the array aperture. We use 3 arrays with 64 antennas (6m linear...... array, 2m linear array and 25cm by 28cm squared 2D array) serving 8 users holding a handset with 2 antennas. The study of the measurements shows that the propagation characteristics of the channel are stable for all the measured frequencies. We also observe that user proximity and user handgrip...... stabilize the studied properties of the channel across the frequencies, and in such case the larger the aperture of the array the more stable the properties. The number of base station antennas improves the propagation characteristics of the channel and stabilizes the properties in the frequency domain....

  12. Multi-frequency eddy current testing method

    International Nuclear Information System (INIS)

    Levy, R.; Gallet, G.

    1980-01-01

    Monitoring by multi-frequency eddy currents has been used since 1975 in French nuclear stations; this method applies perfectly to examinations in non-irradiated surroundings. The restrictions connected with operations in controlled zones (radioactivity) have led to the development of a delayed analysis device which in no way changes the principle of the method, but allows greater flexibility of use by reducing the volume of equipment needed and by limiting the intervention of personnel to a strict minimum [fr

  13. Modeling metro users' travel behavior in Tehran: Frequency of Use

    Directory of Open Access Journals (Sweden)

    Amir Reza Mamdoohi

    2016-10-01

    Full Text Available Transit-oriented development (TOD, as a sustainable supporting strategy, emphasizes the improvement of public transportation coverage and quality, land use density and diversity of around public transportation stations and priority of walking and cycling at station areas. Traffic, environmental and economic problems arising from high growth of personal car, inappropriate distribution of land use, and car-orientation of metropolitan area, necessitate adoption of TOD. In recent years, more researches on urban development and transportation have focused on this strategy. This research considering metro stations as base for development, aims to model metro users' travel behavior and decision-making procedures. In this regard, research question is: what are the parameters or factors affecting in the frequency of travel by metro in half-mile radius from stations. The radius was determine based on TOD definitions and 5 minute walking time to metro stations.  A questionnaire was designed in three sections that including travel features by metro, attitudes toward metro, economic and social characteristics of respondents. Ten stations were selected based on their geographic dispersion in Tehran and a sample of 450 respondents was determined. The questionnaires were surveyed face to face in (half-mile vicinity of metro stations. Based on a refined sample on 400 questionnaires ordered discrete choice models were considered. Results of descriptive statistics show that 38.5 percent of the sample used metro more than 4 times per week. Trip purpose for 45.7 percent of metro users is work. Access mode to the metro stations for nearly half of the users (47.6 percent is bus. Results of ordered logit models show a number of significant variables including: habit of using the metro, waiting time in station, trip purpose (working, shopping and recreation, personal car access mode to the metro station, walking access mode to the metro station and being a housewife.

  14. Guidelines for Learning Stations.

    Science.gov (United States)

    Fehrle, Carl C.; Schulz, Jolene

    Guidelines for designing and planning learning stations for pupils at the elementary grade level include suggestions on how to develop a station that will be successful in meeting the learners' needs. Instructions for the use of tapes at a station and matching pupils with stations are given, as are guidelines on classroom arrangement and record…

  15. Model of nuclear reactor type VVER-1000/V-320 built by computer code ATHLET-CD

    International Nuclear Information System (INIS)

    Georgiev, Yoto; Filipov, Kalin; Velev, Vladimir

    2014-01-01

    A model of nuclear reactor type VVER-1000 V-320 developed for computer code ATHLET-CD2.1A is presented. Validation of the has been made, in the analysis of the station blackout scenario with LOCA on fourth cold leg is shown. As the calculation has been completed, the results are checked through comparison with the results from the computer codes ATHLET-2.1A, ASTEC-2.1 and RELAP5mod3.2

  16. Computer simulation of black out followed by multiple failures in PWR type nuclear power plants

    International Nuclear Information System (INIS)

    Silva Filho, E.

    1989-01-01

    The computer code RELAP 5/MOD 1 has been utilized to investigate the thermal-hydraulic behaviour of a standard 1300 MWe pressurized water reactor plant of the KWU design during a station blackout following a inadequate performance of the pressurizer and steam generator safety valves. During the simulation the reactor scram system the emergency coolant system of the primary loop and the emergency Feedwater system of the secondary loop are considered inactive. (author) [pt

  17. Developmental state and perspectives of USSR power stations, espec. nuclear power stations

    International Nuclear Information System (INIS)

    1983-01-01

    According to the resolutions of the 25th and 26th party congresses of the CPSU, the Soviet electric and thermal energy economy envisages as the mainstreams in development: Energy projects based on nuclear fuel, i.e. nuclear power stations (NPS), nuclear heat- and -power stations (NHPS) and nuclear heat stations (NHS); fuel-energy complexes: Ekibastuz, Kansk-Achinsk, West-Siberian complex (Tyumen); power stations utilizing non-conventional regenerative energy sources, i.e. solar, geothermal, MHD power stations. Further down, an overview is given on the developmental perspectives of nuclear-heat and nuclear-power economy and on the development of energy management based on fossil fuels. (orig./UA) [de

  18. 47 CFR 95.139 - Adding a small base station or a small control station.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Adding a small base station or a small control... base station or a small control station. (a) Except for a GMRS system licensed to a non-individual, one or more small base stations or a small control station may be added to a GMRS system at any point...

  19. Frequency Based Real-time Pricing for Residential Prosumers

    Science.gov (United States)

    Hambridge, Sarah Mabel

    This work is the first to explore frequency based pricing for secondary frequency control as a price-reactive control mechanism for residential prosumers. A frequency based real-time electricity rate is designed as an autonomous market control mechanism for residential prosumers to provide frequency support as an ancillary service. In addition, prosumers are empowered to participate in dynamic energy transactions, therefore integrating Distributed Energy Resources (DERs), and increasing distributed energy storage onto the distributed grid. As the grid transitions towards DERs, a new market based control system will take the place of the legacy distributed system and possibly the legacy bulk power system. DERs provide many benefits such as energy independence, clean generation, efficiency, and reliability to prosumers during blackouts. However, the variable nature of renewable energy and current lack of installed energy storage on the grid will create imbalances in supply and demand as uptake increases, affecting the grid frequency and system operation. Through a frequency-based electricity rate, prosumers will be encouraged to purchase energy storage systems (ESS) to offset their neighbor's distributed generation (DG) such as solar. Chapter 1 explains the deregulation of the power system and move towards Distributed System Operators (DSOs), as prosumers become owners of microgrids and energy cells connected to the distributed system. Dynamic pricing has been proposed as a benefit to prosumers, giving them the ability to make decisions in the energy market, while also providing a way to influence and control their behavior. Frequency based real-time pricing is a type of dynamic pricing which falls between price-reactive control and transactive control. Prosumer-to-prosumer transactions may take the place of prosumer-to-utility transactions, building The Energy Internet. Frequency based pricing could be a mechanism for determining prosumer prices and supporting

  20. A Guide to the Application of Probability Risk Assessment Methodology and Hazard Risk Frequency Criteria as a Hazard Control for the Use of the Mobile Servicing System on the International Space Station

    Science.gov (United States)

    D'silva, Oneil; Kerrison, Roger

    2013-09-01

    A key feature for the increased utilization of space robotics is to automate Extra-Vehicular manned space activities and thus significantly reduce the potential for catastrophic hazards while simultaneously minimizing the overall costs associated with manned space. The principal scope of the paper is to evaluate the use of industry standard accepted Probability risk/safety assessment (PRA/PSA) methodologies and Hazard Risk frequency Criteria as a hazard control. This paper illustrates the applicability of combining the selected Probability risk assessment methodology and hazard risk frequency criteria, in order to apply the necessary safety controls that allow for the increased use of the Mobile Servicing system (MSS) robotic system on the International Space Station. This document will consider factors such as component failure rate reliability, software reliability, and periods of operation and dormancy, fault tree analyses and their effects on the probability risk assessments. The paper concludes with suggestions for the incorporation of existing industry Risk/Safety plans to create an applicable safety process for future activities/programs

  1. Predictors of suicide and suicide attempt in subway stations: a population-based ecological study.

    Science.gov (United States)

    Niederkrotenthaler, Thomas; Sonneck, Gernot; Dervic, Kanita; Nader, Ingo W; Voracek, Martin; Kapusta, Nestor D; Etzersdorfer, Elmar; Mittendorfer-Rutz, Ellenor; Dorner, Thomas

    2012-04-01

    Suicidal behavior on the subway often involves young people and has a considerable impact on public life, but little is known about factors associated with suicides and suicide attempts in specific subway stations. Between 1979 and 2009, 185 suicides and 107 suicide attempts occurred on the subway in Vienna, Austria. Station-specific suicide and suicide attempt rates (defined as the frequency of suicidal incidents per time period) were modeled as the outcome variables in bivariate and multivariate Poisson regression models. Structural station characteristics (presence of a surveillance unit, train types used, and construction on street level versus other construction), contextual station characteristics (neighborhood to historical sites, size of the catchment area, and in operation during time period of extensive media reporting on subway suicides), and passenger-based characteristics (number of passengers getting on the trains per day, use as meeting point by drug users, and socioeconomic status of the population in the catchment area) were used as the explanatory variables. In the multivariate analyses, subway suicides increased when stations were served by the faster train type. Subway suicide attempts increased with the daily number of passengers getting on the trains and with the stations' use as meeting points by drug users. The findings indicate that there are some differences between subway suicides and suicide attempts. Completed suicides seem to vary most with train type used. Suicide attempts seem to depend mostly on passenger-based characteristics, specifically on the station's crowdedness and on its use as meeting point by drug users. Suicide-preventive interventions should concentrate on crowded stations and on stations frequented by risk groups.

  2. Reducing the Vulnerability of Electric Power Grids to Terrorist Attacks

    Energy Technology Data Exchange (ETDEWEB)

    Ross Baldick; Thekla Boutsika; Jin Hur; Manho Joung; Yin Wu; Minqi Zhong

    2009-01-31

    This report describes the development of a cascading outage analyzer that, given an initial disturbance on an electric power system, checks for thermal overloads, under-frequency and over-frequency conditions, and under-voltage conditions that would result in removal of elements from the system. The analyzer simulates the successive tripping of elements due to protective actions until a post-event steady state or a system blackout is reached.

  3. [Risk-oriented model of the control of the level of electric magnetic fields of base stations of cellular communications].

    Science.gov (United States)

    Lutsenko, L A; Tulakin, A V; Egorova, A M; Mikhailova, O M; Gvozdeva, L L; Chigryay, E K

    The purpose of this study was to give the description of harmful effects of the impact of electromagnetic radiations from base stations of cellular communication as the most common sources of radio frequencies of electromagnetic fields in the environment. The highest values of the energy flux density were measured on the roofs of houses where antennas are installed - more than 10 pW/cm. The lowest values were recorded in inside premises with expositions of 0.1-1 pW/cm. In the close location of the railway station to the base stations of the cellular communication there was seen a cumulative effect. There are proposed both new safe hygienic approaches to the control for the safety of the work of base station and protective measures.

  4. Ground based observations of Pc3-Pc5 geomagnetic pulsation power at Antarctic McMurdo station

    Directory of Open Access Journals (Sweden)

    C. G. Maclennan

    1998-06-01

    Full Text Available The two horizontal geomagnetic components and, measured by a fluxgate magnetometer at Antarctic McMurdo station (corrected geomagnetic coordinates 80.0° S, 327.5° E, are analyzed for the period May-June 1994; the spectral powers are calculated and integrated over three frequency intervals corresponding to the nominal ranges. The time dependence of those integrated powers and their correlations with northern auroral indices and solar wind speed are considered. The observations are compared with previous results reported from Terra Nova Bay station (located near McMurdo at the same corrected geomagnetic latitude during Antarctic summer intervals. The differences found between the two stations are discussed in terms of the seasonal dependence of geomagnetic field line configurations in the near cusp region.

  5. Developments of space station; Uchu station no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, H. [National Space Development Agency of Japan, Tokyo (Japan)

    1996-03-05

    This paper introduces the Japanese experiment module (JEM) in developing a space station. The JEM consists of systems of a pressurizing section, an exposure section, a pressurizing portion of a supply section, a manipulator and an exposure portion of the supply section. The pressurizing section circulates and controls air so that crews can perform experiments under pressurized environment. The exposure section is a part in which experiments are carried out under exposure environment. The supply section runs between a station and the ground, with required devices loaded on it. The manipulator performs attaching a payload for the exposure section and replaces experimental samples. The JEM undergoes a schedule of fabricating an engineering model, testing for a certification a prototype flight model, and putting the model on a flight. The pressurizing section, exposure section and manipulator are at the stage of system tests. Surveillance of the JEM and control of the experiments are carried out at the Tsukuba Space Center. The Center is composed of a space experiment building, a zero-gravity environment testing building, an astronaut training building, a space station operating building, and a space station testing building. 7 figs., 2 tabs.

  6. OBSERVATIONS OF ROTATING RADIO TRANSIENTS WITH THE FIRST STATION OF THE LONG WAVELENGTH ARRAY

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, G. B.; Stovall, K.; McCrackan, M.; Dowell, J.; Schinzel, F. K. [Department of Physics and Astronomy, University of New Mexico, Albuquerque NM, 87131 (United States); McLaughlin, M. A.; Miller, R. [Department of Physics and Astronomy, West Virginia University, Morgantown, WV 26506-6315 (United States); Karako-Argaman, C. [Department of Physics, McGill University, 3600 University Street, Montreal, QC H3A 2T8 (Canada)

    2016-11-10

    Rotating radio transients (RRATs) are a subclass of pulsars first identified in 2006 that are detected only in searches for single pulses and not through their time averaged emission. Here, we present the results of observations of 19 RRATs using the first station of the Long Wavelength Array (LWA1) at frequencies between 30 and 88 MHz. The RRATs observed here were first detected in higher frequency pulsar surveys. Of the 19 RRATs observed, two sources were detected and their dispersion measures, periods, pulse profiles, and flux densities are reported and compared to previous higher frequency measurements. We find a low detection rate (11%), which could be a combination of the lower sensitivity of LWA1 compared to higher frequency telescopes, and the result of scattering by the interstellar medium or a spectral turnover.

  7. Risk impact of planned maintenance configuration at South Texas Project Electric Generating Station

    International Nuclear Information System (INIS)

    Loh, W.T.; Fleming, K.N.; Grantom, C.R.

    2004-01-01

    This paper is based on a study done for the Houston Lighting and Power Company. The purpose of this study is to estimate the risk impact of planned maintenance configurations at South Texas Project Electric Generating Station (STPEGS). To date, the focus of the STP probabilistic safety assessment (PSA) program has been to analyze risk in terms of estimates of accident frequencies that are expressed on a time-averaged basis. Thus, estimates of quantities such as severe core damage frequency have been made such that the temporal variations of this frequency with changing plant configurations are averaged out over time. The only condition that has been imposed on these estimates is that the plant is initially operating at full power when potential initiating events might occur. (author)

  8. The temporal and spatial variations of low frequency geomagnetic pulsations at polar cusp and cap latitudes

    Directory of Open Access Journals (Sweden)

    J. Bitterly

    1999-06-01

    Full Text Available Geomagnetic field measurements at two Antarctic stations are compared during two weeks in the local summer (January 1-15, 1992. Low frequency (0.6-6 mHz pulsations are observed at each station near local magnetic noon. The same wave packets appear in some cases also at the other station, although with a significant attenuation, more clearly in the morning sector; the waves show a near noon reversal of the polarization sense from counter-clockwise in the morning to clockwise in the afternoon indicating a westward and an eastward propagation, respectively.

  9. Global Application of TaiWan Ionospheric Model to Single-Frequency GPS Positioning

    Science.gov (United States)

    Macalalad, E.; Tsai, L. C.; Wu, J.

    2012-04-01

    Ionospheric delay is one the major sources of error in GPS positioning and navigation. This error in both pseudorange and phase ranges vary depending on the location of observation, local time, season, solar cycle and geomagnetic activity. For single-frequency receivers, this delay is usually removed using ionospheric models. Two of them are the Klobuchar, or broadcast, model and the global ionosphere map (GIM) provided by the International GNSS Service (IGS). In this paper, a three dimensional ionospheric electron (ne) density model derived from FormoSat3/COSMIC GPS Radio Occultation measurements, called the TaiWan Ionosphere Model, is used. It was used to calculate the slant total electron content (STEC) between receiver and GPS satellites to correct the pseudorange single-frequency observations. The corrected pseudorange for every epoch was used to determine a more accurate position of the receiver. Observations were made in July 2, 2011(Kp index = 0-2) in five randomly selected sites across the globe, four of which are IGS stations (station ID: cnmr, coso, irkj and morp) while the other is a low-cost single-frequency receiver located in Chungli City, Taiwan (ID: isls). It was illustrated that TEC maps generated using TWIM exhibited a detailed structure of the ionosphere, whereas Klobuchar and GIM only provided the basic diurnal and geographic features of the ionosphere. Also, it was shown that for single-frequency static point positioning TWIM provides more accurate and more precise positioning than the Klobuchar and GIM models for all stations. The average %error of the corrections made by Klobuchar, GIM and TWIM in DRMS are 3.88%, 0.78% and 17.45%, respectively. While the average %error in VRMS for Klobuchar, GIM and TWIM are 53.55%, 62.09%, 66.02%, respectively. This shows the capability of TWIM to provide a good global 3-dimensional ionospheric model.

  10. Evaluation of chromosome aberration and micronucleus frequencies in blood lymphocytes of workers exposed to low concentrations of benzene.

    Science.gov (United States)

    Lovreglio, Piero; Maffei, Francesca; Carrieri, Mariella; D'Errico, Maria N; Drago, Ignazio; Hrelia, Patrizia; Bartolucci, Giovanni B; Soleo, Leonardo

    2014-08-01

    The frequency of chromosome aberrations (CA) and micronuclei (MN) was investigated in the peripheral lymphocytes of workers occupationally exposed to low or very low concentrations of benzene. The study included 43 exposed workers (all males), namely 19 fuel-tanker drivers and 24 filling-station attendants, and 31 male subjects with no occupational exposure to the toxicant (controls). Benzene exposure was verified by means of environmental monitoring with passive personal samplers (Radiello(®)), and through biological monitoring, i.e. by measurement of urinary trans,trans-muconic acid, S-phenylmercapturic acid and benzene. The frequency of CA and MN in peripheral lymphocytes was determined according to standard procedures. Exposure to benzene was found to be significantly higher for fuel-tanker drivers (median 246.6 μg/m(3)) than for filling-station attendants (median 19.9 μg/m(3)). Both groups had significantly higher exposure than controls (median 4.3 μg/m(3)). No increased frequency of CA and MN was observed in either fuel-tanker drivers or filling-station attendants compared with controls. In all subjects examined as a single group, the frequency of MN was significantly dependent on age. Only in the fuel-tanker drivers was the frequency of MN found to depend not only on age, but also on exposure to benzene. In conclusion, the frequency of MN, but not of CA, could be influenced by exposure to benzene concentrations of up to one order of magnitude lower than the threshold limit value (time-weighted average). Copyright © 2014 Elsevier B.V. All rights reserved.

  11. The generation of simple compliance boundaries for mobile communication base station antennas using formulae for SAR estimation.

    Science.gov (United States)

    Thors, B; Hansson, B; Törnevik, C

    2009-07-07

    In this paper, a procedure is proposed for generating simple and practical compliance boundaries for mobile communication base station antennas. The procedure is based on a set of formulae for estimating the specific absorption rate (SAR) in certain directions around a class of common base station antennas. The formulae, given for both whole-body and localized SAR, require as input the frequency, the transmitted power and knowledge of antenna-related parameters such as dimensions, directivity and half-power beamwidths. With knowledge of the SAR in three key directions it is demonstrated how simple and practical compliance boundaries can be generated outside of which the exposure levels do not exceed certain limit values. The conservativeness of the proposed procedure is discussed based on results from numerical radio frequency (RF) exposure simulations with human body phantoms from the recently developed Virtual Family.

  12. Newport Research Station

    Data.gov (United States)

    Federal Laboratory Consortium — The Newport Research Station is the Center's only ocean-port research facility. This station is located at Oregon State University's Hatfield Marine Science Center,...

  13. Electron content near the lunar surface using dual-frequency VLBI tracking data in a single lunar orbiter mission

    International Nuclear Information System (INIS)

    Wang, Zhen; Wang, Na; Ping, Jin-Song

    2015-01-01

    In VLBI observations of Vstar, a subsatellite of the Japanese lunar mission SELENE, there were opportunities for lunar grazing occultation when Vstar was very close to the limb of the Moon. This kind of chance made it possible to probe the thin plasma layer above the Moon's surface as a meaningful by-product of VLBI, by using the radio occultation method with coherent radio waves from the S/X bands. The dual-frequency measurements were carried out at Earth-based VLBI stations. In the line-of-sight direction between the satellite and the ground-based tracking station where VLBI measurements were made, the effects of the terrestrial ionosphere, interplanetary plasma and the thin lunar ionosphere mixed together in the combined observables of dual-frequency Doppler shift and phase shift. To separate the variation of the ionospheric total electron content (TEC) near the surface of the Moon from the mixed signal, the influences of the terrestrial ionosphere and interplanetary plasma have been removed by using an extrapolation method based on a short-term trend. The lunar TEC is estimated from the dual-frequency observation for Vstar from UT 22:18 to UT 22:20 on 2008 June 28 at several tracking stations. The TEC results obtained from VLBI sites are identical, however, they are not as remarkable as the result obtained at the Usuda deep space tracking station. (paper)

  14. Determination of exposure due to mobile phone base stations in an epidemiological study

    International Nuclear Information System (INIS)

    Neitzke, H. P.; Osterhoff, J.; Peklo, K.; Voigt, H.

    2007-01-01

    To investigate a supposed relationship between exposure by mobile phone base stations and well-being, an epidemiological cross sectional study is carried out within the German Mobile Telecommunication Research Program. In a parallel project, a method for the classification of electromagnetic exposure due to mobile phone base stations has been developed. This is based on the results of measurements of high frequency immissions in the interior of more than 1100 rooms and at outdoor locations, the calculation of the emissions of mobile phone antennas under free space propagation conditions and empirically determined transmission factors for the propagation of electromagnetic waves in different types of residential areas for passage of walls and windows. Standard tests (correlation-test, kappa-test, Bland-Altman-Plot, analysis of sensitivity and specificity) show that the method for computational exposure assessment developed in this project is applicable for a first classification of exposures due to mobile phone base stations in epidemiological studies. (authors)

  15. Station Set Residual: Event Classification Using Historical Distribution of Observing Stations

    Science.gov (United States)

    Procopio, Mike; Lewis, Jennifer; Young, Chris

    2010-05-01

    Analysts working at the International Data Centre in support of treaty monitoring through the Comprehensive Nuclear-Test-Ban Treaty Organization spend a significant amount of time reviewing hypothesized seismic events produced by an automatic processing system. When reviewing these events to determine their legitimacy, analysts take a variety of approaches that rely heavily on training and past experience. One method used by analysts to gauge the validity of an event involves examining the set of stations involved in the detection of an event. In particular, leveraging past experience, an analyst can say that an event located in a certain part of the world is expected to be detected by Stations A, B, and C. Implicit in this statement is that such an event would usually not be detected by Stations X, Y, or Z. For some well understood parts of the world, the absence of one or more "expected" stations—or the presence of one or more "unexpected" stations—is correlated with a hypothesized event's legitimacy and to its survival to the event bulletin. The primary objective of this research is to formalize and quantify the difference between the observed set of stations detecting some hypothesized event, versus the expected set of stations historically associated with detecting similar nearby events close in magnitude. This Station Set Residual can be quantified in many ways, some of which are correlated with the analysts' determination of whether or not the event is valid. We propose that this Station Set Residual score can be used to screen out certain classes of "false" events produced by automatic processing with a high degree of confidence, reducing the analyst burden. Moreover, we propose that the visualization of the historically expected distribution of detecting stations can be immediately useful as an analyst aid during their review process.

  16. Weather Radar Stations

    Data.gov (United States)

    Department of Homeland Security — These data represent Next-Generation Radar (NEXRAD) and Terminal Doppler Weather Radar (TDWR) weather radar stations within the US. The NEXRAD radar stations are...

  17. Real-Time Station Grouping under Dynamic Traffic for IEEE 802.11ah.

    Science.gov (United States)

    Tian, Le; Khorov, Evgeny; Latré, Steven; Famaey, Jeroen

    2017-07-04

    IEEE 802.11ah, marketed as Wi-Fi HaLow, extends Wi-Fi to the sub-1 GHz spectrum. Through a number of physical layer (PHY) and media access control (MAC) optimizations, it aims to bring greatly increased range, energy-efficiency, and scalability. This makes 802.11ah the perfect candidate for providing connectivity to Internet of Things (IoT) devices. One of these new features, referred to as the Restricted Access Window (RAW), focuses on improving scalability in highly dense deployments. RAW divides stations into groups and reduces contention and collisions by only allowing channel access to one group at a time. However, the standard does not dictate how to determine the optimal RAW grouping parameters. The optimal parameters depend on the current network conditions, and it has been shown that incorrect configuration severely impacts throughput, latency and energy efficiency. In this paper, we propose a traffic-adaptive RAW optimization algorithm (TAROA) to adapt the RAW parameters in real time based on the current traffic conditions, optimized for sensor networks in which each sensor transmits packets with a certain (predictable) frequency and may change the transmission frequency over time. The TAROA algorithm is executed at each target beacon transmission time (TBTT), and it first estimates the packet transmission interval of each station only based on packet transmission information obtained by access point (AP) during the last beacon interval. Then, TAROA determines the RAW parameters and assigns stations to RAW slots based on this estimated transmission frequency. The simulation results show that, compared to enhanced distributed channel access/distributed coordination function (EDCA/DCF), the TAROA algorithm can highly improve the performance of IEEE 802.11ah dense networks in terms of throughput, especially when hidden nodes exist, although it does not always achieve better latency performance. This paper contributes with a practical approach to optimizing

  18. WIND SPEED AND ATMOSPHERIC STABILITY TRENDS FOR SELECTED UNITED STATES SURFACE STATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, R; Allen H. Weber, A

    2006-11-01

    Recently it has been suggested that global warming and a decrease in mean wind speeds over most land masses are related. Decreases in near surface wind speeds have been reported by previous investigators looking at records with time spans of 15 to 30 years. This study focuses on United States (US) surface stations that have little or no location change since the late 1940s or the 1950s--a time range of up to 58 years. Data were selected from 62 stations (24 of which had not changed location) and separated into ten groups for analysis. The group's annual averages of temperature, wind speed, and percentage of Pasquill-Gifford (PG) stability categories were fitted with linear least squares regression lines. The results showed that the temperatures have increased for eight of the ten groups as expected. Wind speeds have decreased for nine of the ten groups. The mean slope of the wind speed trend lines for stations within the coterminous US was -0.77 m s{sup -1} per century. The percentage frequency of occurrence for the neutral (D) PG stability category decreased, while that for the unstable (B) and the stable (F) categories increased in almost all cases except for the group of stations located in Alaska.

  19. Exposure assessment in front of a multi-band base station antenna.

    Science.gov (United States)

    Kos, Bor; Valič, Blaž; Kotnik, Tadej; Gajšek, Peter

    2011-04-01

    This study investigates occupational exposure to electromagnetic fields in front of a multi-band base station antenna for mobile communications at 900, 1800, and 2100 MHz. Finite-difference time-domain method was used to first validate the antenna model against measurement results published in the literature and then investigate the specific absorption rate (SAR) in two heterogeneous, anatomically correct human models (Virtual Family male and female) at distances from 10 to 1000 mm. Special attention was given to simultaneous exposure to fields of three different frequencies, their interaction and the additivity of SAR resulting from each frequency. The results show that the highest frequency--2100 MHz--results in the highest spatial-peak SAR averaged over 10 g of tissue, while the whole-body SAR is similar at all three frequencies. At distances > 200 mm from the antenna, the whole-body SAR is a more limiting factor for compliance to exposure guidelines, while at shorter distances the spatial-peak SAR may be more limiting. For the evaluation of combined exposure, a simple summation of spatial-peak SAR maxima at each frequency gives a good estimation for combined exposure, which was also found to depend on the distribution of transmitting power between the different frequency bands. Copyright © 2010 Wiley-Liss, Inc.

  20. Locating Very-Low-Frequency Earthquakes in the San Andreas Fault.

    Science.gov (United States)

    Peña-Castro, A. F.; Harrington, R. M.; Cochran, E. S.

    2016-12-01

    The portion of tectonic fault where rheological properties transtition from brittle to ductile hosts a variety of seismic signals suggesting a range of slip velocities. In subduction zones, the two dominantly observed seismic signals include very-low frequency earthquakes ( VLFEs), and low-frequency earthquakes (LFEs) or tectonic tremor. Tremor and LFE are also commonly observed in transform faults, however, VLFEs have been reported dominantly in subduction zone environments. Here we show some of the first known observations of VLFEs occurring on a plate boundary transform fault, the San Andreas Fault (SAF) between the Cholame-Parkfield segment in California. We detect VLFEs using both permanent and temporary stations in 2010-2011 within approximately 70 km of Cholame, California. We search continous waveforms filtered from 0.02-0.05 Hz, and remove time windows containing teleseismic events and local earthquakes, as identified in the global Centroid Moment Tensor (CMT) and the Northern California Seismic Network (NCSN) catalog. We estimate the VLFE locations by converting the signal into envelopes, and cross-correlating them for phase-picking, similar to procedures used for locating tectonic tremor. We first perform epicentral location using a grid search method and estimate a hypocenter location using Hypoinverse and a shear-wave velocity model when the epicenter is located close to the SAF trace. We account for the velocity contrast across the fault using separate 1D velocity models for stations on each side. Estimated hypocentral VLFE depths are similar to tremor catalog depths ( 15-30 km). Only a few VLFEs produced robust hypocentral locations, presumably due to the difficulty in picking accurate phase arrivals with such a low-frequency signal. However, for events for which no location could be obtained, the moveout of phase arrivals across the stations were similar in character, suggesting that other observed VLFEs occurred in close proximity.

  1. Investigation of the receivability of VLF standard time and frequency ...

    African Journals Online (AJOL)

    This study is on the receivability of some standard time and frequency signals in the VLF range in Zaria, Nigeria. Signal field strengths of various stations were estimated, and a suitable radio receiving system was set up to receive them. Using the assembled receiver, some of the transmissions, including the Omega W/L at ...

  2. Streamflow Gaging Stations

    Data.gov (United States)

    Department of Homeland Security — This map layer shows selected streamflow gaging stations of the United States, Puerto Rico, and the U.S. Virgin Islands, in 2013. Gaging stations, or gages, measure...

  3. Ocean Station Vessel

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean Station Vessels (OSV) or Weather Ships captured atmospheric conditions while being stationed continuously in a single location. While While most of the...

  4. MELCOR DB Construction for the Severe Accident Analysis DB

    International Nuclear Information System (INIS)

    Song, Y. M.; Ahn, K. I.

    2011-01-01

    The Korea Atomic Energy Research Institute (KAERI) has been constructing a severe accident analysis database (DB) under a National Nuclear R and D Program. In particular, an MAAP (commercial code being widely used in industries for integrated severe accident analysis) DB for many scenarios including a station blackout (SBO) has been completed. This paper shows the MELCOR DB construction process with examples of SBO scenarios, and the results will be used for a comparison with the MAAP DB

  5. Essence and characteristics of the Westinghouse technology AP1000

    International Nuclear Information System (INIS)

    Llovet, Ricardo

    2014-01-01

    The AP1000 nuclear power plant can place the reactor in a Safe Shutdown Condition within the first 72 hours of a Station Blackout, without the use of AC power or operator action •With some operator action after 3 days, the AP1000 nuclear power plant continues to maintain reactor core cooling and Spent Fuel Pool cooling indefinitely •The AP1000 nuclear power plant has superior coping capabilities as well as significantly reduced risk for core damage

  6. Main results of assessing integrity of RNPP-3 steam generator heat exchange tubes in accident management

    International Nuclear Information System (INIS)

    Shugajlo, Al-j P.; Mustafin, M.A.; Shugajlo, Al-r P.; Ryzhov, D.I.; Zhabin, O.I.

    2017-01-01

    Tubes integrity evaluation under accident conditions considering drain of SG and current technical state of steam exchange tubes is an important question regarding SG long-term operation and improvement of accident management strategy.The main investigation results prepared for heat exchange surface of RNPP-3 steam generator are presented in this research aimed at assessing integrity of heat exchange tubes under accident conditions, which lead to full or partial drain of heat exchange surface, in particular during station blackout.

  7. A Study on the Radio Coverage in Underground Stations of the New Copenhagen Metro System

    DEFF Research Database (Denmark)

    Millan, Maria del Carmen de la O; Sørensen, Troels Bundgaard; Mikkelsen, Niels Michael

    2013-01-01

    In connection with the extension of the Copenhagen Metro system, architects and wireless operators met early in the design phase to plan the radio coverage inside the public areas of the metro transport system. Based on common best practice, an initial design for the antenna installations......, and hence radio coverage, was proposed for a distributed antenna system in each of two distinctly different types of underground stations. In this paper, we describe the considerations for the design, and specifically the modelling and analysis of the underground stations by way of a commercial ray......-tracing tool. Radio coverage results are given for different designs, including different number and types of antennas, their configuration and placement, as well as the dependency on frequency and construction materials and presence of trains on the station platforms. In a practical case like this...

  8. Reference Climatological Stations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Reference Climatological Stations (RCS) network represents the first effort by NOAA to create and maintain a nationwide network of stations located only in areas...

  9. Path Transmissibility Analysis Considering Two Types of Correlations in Hydropower Stations

    Directory of Open Access Journals (Sweden)

    Baoping Zhi

    2013-01-01

    Full Text Available A new vibration model is built by introducing the head-cover vibration transfer path based on a previous analysis of the vertical vibration model for hydropower station units and powerhouses. This research focuses on disturbance- and parameter-related transfer paths in a practical situation. In a complex situation, the application of the stochastic perturbation method is expanded using an algebra synthesis method the Hadamard product, and theoretical analyses, and numerical simulations of transfer paths in the new vibration model are carried out through the expanded perturbation method. The path transfer force, the path transmissibility, and the path disturbance ranges in the frequency domain are provided. The results indicate that the methods proposed in this study can efficiently reduce the disturbance range and can accurately analyze the transfer paths of hydraulic-source vertical vibration in hydropower stations.

  10. Inferring Social Functions Available in the Metro Station Area from Passengers’ Staying Activities in Smart Card Data

    Directory of Open Access Journals (Sweden)

    Yang Zhou

    2017-12-01

    Full Text Available The function of a metro station area is vital for city planners to consider when establishing a context-aware Transit-Oriented Development policy around the station area. However, the functions of metro station areas are hard to infer using the static land use distribution and other traditional survey datasets. In this paper, we propose a method to infer the functions occurring around the metro station catchment areas according to the patterns of staying activities derived from smart card data. We first define the staying activities by the spatial and temporal constraints of the two consecutive alighting and boarding records from the individual travel profile. Then we cluster and label the whole staying activities by considering the features of duration, frequency, and start time. By analyzing the percentage of different types of aggregated activities happening around each metro station, we cluster and explore the functions of the metro station area. Taking Wuhan as a case study, we analyze the results of Wuhan metro systems and discuss the similarities and differences between the functions and the land use distribution around the station area. The results show that although there exist some agreements, there is also a gap between the human activities and the land uses around the station area. These findings could give us deeper insight into how people act around the stations by metro systems, which will ultimately benefit the urban planning and policy development.

  11. Fire Stations - 2007

    Data.gov (United States)

    Kansas Data Access and Support Center — Fire Station Locations in Kansas Any location where fire fighters are stationed at or based out of, or where equipment that such personnel use in carrying out their...

  12. Fire Stations - 2009

    Data.gov (United States)

    Kansas Data Access and Support Center — Fire Stations in Kansas Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their jobs is...

  13. [STEM on Station Education

    Science.gov (United States)

    Lundebjerg, Kristen

    2016-01-01

    The STEM on Station team is part of Education which is part of the External Relations organization (ERO). ERO has traditional goals based around BHAG (Big Hairy Audacious Goal). The BHAG model is simplified to a saying: Everything we do stimulates actions by others to advance human space exploration. The STEM on Station education initiate is a project focused on bringing off the earth research and learning into classrooms. Educational resources such as lesson plans, activities to connect with the space station and STEM related contests are available and hosted by the STEM on Station team along with their partners such as Texas Instruments. These educational activities engage teachers and students in the current happenings aboard the international space station, inspiring the next generation of space explorers.

  14. Probabilistic safety assessment of Narora Atomic Power Project

    International Nuclear Information System (INIS)

    Babar, A.K.; Saraf, R.K.; Kakodkar, A.; Sanyasi Rao, V.V.S.

    1989-01-01

    Various safety studies on Pressurised Water and Boiling Water reactors have been conducted. However, a detailed report on probabilistic safety assessment (PSA) of PHWRs is not available. PSA level I results of the standardised 235 MWe PHWR under construction at Narora are presented herein. Fault Tree analysis of various initiating events (IEs), safety systems has been completed. Event Tree analysis has been performed for all the dominating IEs to identify the accident sequences and a list of the dominating accident sequences is included. Analysis has been carried out using Monte Carlo simulation to propagate the uncertanities in failure rate data. Further uncertainty analysis is extended to obtain distributions for the accident sequences and core damage frequency. Some noteworthy results of the study apart from the various design modifications incorporated during the design phase are: (i) The accident sequences resulting from station blackout are dominant contributors to the core damage frequency. (ii) Class-IV transients, small break LOCA are significant IEs. Main steam line break is likely to induce steam generator tube ruptures. (iii) Moderator circulation, fire fighting system, secondary steam relief are relatively important in core damage frequency reductions. (iv) Under accidental situations human errors are likely to be asociated with valving in shutdown cooling and fire fighting systems. (author). 14 tabs., 14 figs., 15 refs

  15. A simplified time-dependent recovery model as applied to RCP seal LOCAs

    International Nuclear Information System (INIS)

    Kohut, P.; Bozoki, G.; Fitzpatrick, R.

    1991-01-01

    In Westinghouse-designed reactors, the reactor coolant pump (RCP) seals constantly require a modest amount of cooling. This cooling function depends on the service water (SW) system. Upon the loss of the cooling function due to the unavailability of the SW, component cooling water system or electrical power (station blackout), the RCP seals may degrade, resulting in a loss-of-coolant accident (LOCA). Recent studies indicate that the frequency of the loss of SW initiating events is higher than previously thought. This change significantly increases the core damage frequency contribution from RCP seal failure. The most critical/dominant element in the loss of SW events was found to be the SW-induced RCP seal failure. For these potential accident scenarios, there are large uncertainties regarding the actual frequency of RCP seal LOCA, the resulting leakage rate, and time-dependent behavior. The roles of various recovery options based on the time evolution of the seal LOCA have been identified and taken into account in recent NUREG-1150 probabilistic risk assessment PRA analyses. In this paper, a consistent time-dependent recovery model is described that takes into account the effects of various recovery actions based on explicit considerations given to a spectrum of time- and flow-rate dependencies. The model represents a simplified approach but is especially useful when extensive seal leak rate and core uncovery information is unavailable

  16. IAEA Completes Expert Mission to Kori 1 Nuclear Power Plant in the Republic of Korea

    International Nuclear Information System (INIS)

    2012-01-01

    Full text: An international team of nuclear safety experts led by the International Atomic Energy Agency (IAEA) has completed a review of safety practices at the Kori 1 Nuclear Power Plant (NPP) near Busan in the Republic of Korea. The IAEA assembled the team at the request of Korea Hydro and Nuclear Power Co., Ltd. (KHNP) following a station blackout event on 9 February 2012. The team - comprised of experts from Belgium, France, Sweden, United Kingdom and the IAEA - conducted its mission from 4 to 11 June 2012 under the leadership of the IAEA's Division of Nuclear Installation Safety. The expert mission applied the methodology of the IAEA's Operational Safety Review (OSART) missions and covered the areas of Management, Organization and Administration; Operations; Maintenance and Operating Experience. The conclusions of the review are based on the IAEA's Safety Standards, which are developed by the Agency to help nations improve their nuclear safety practices, which are the responsibility of every nation that undertakes nuclear-related activities. Throughout the review, the exchange of information between the experts and plant personnel was very open, professional and productive. Prior to the mission, Korea's Nuclear Safety and Security Commission completed an interim investigation, and it continues to perform additional investigations and technical reviews. The Commission identified corrective actions for the plant concerning reinforcing safety culture, emergency diesel generator reliability, configuration control and risk management during refueling outage, test and maintenance procedures and emergency action level declaration. The expert mission confirmed that some corrective actions have already been completed and others are in progress. The expert mission found the management and staff of Kori 1 NPP to be committed and working hard to complete all improvements. The root cause analysis of the event at Kori 1 NPP is still in progress and is expected to lead to

  17. Station History Of The Seismic Station In Ahmadu Bello University ...

    African Journals Online (AJOL)

    Dominants in the selected events are events from Meditterranian, East Kazakhstan, India/Burma/China, South and Central America and North Ascension island regions. The limited number of events reporting at the station was due to low operational gain at the station which permitted only events whose magnitudes are ...

  18. The Trencin water power station

    International Nuclear Information System (INIS)

    2005-01-01

    This leaflet describes the Trencin water power station. The Trencin water power station was built seven years after the Dubnica nad Vahom water power station started its operation and was the last stage of the first and the oldest derived cascade of water power stations on the Vah River. After completing water power stations at Ladce (1936), Ilava (1946) and Dubnica nad Vahom (1949) and before constructing the Trencin water power station, the whole second derived cascade of water power stations including water power stations at Kostolna, Nove Mesto nad Vahom and Horna Streda was built as soon as possible mainly because the need to get compensation for discontinued electricity supplies as well as energetic coal from the Czech Republic. Hereby, experiences from the construction of previous grades were used, mainly as far as the dimensioning was concerned, as the fi rst installed power stations had, in comparison with the growing requirements on the electricity supplies, very low absorption capacity - only 150 m 3 .s -1 . Thus the Trencin power station (original name was the Skalka power station) was already dimensioned for the same absorption capacity as the cascade located downstream the river, that is 180 m 3 .s -1 . That was related also to growing demands on electricity supplies during the peaks in the daily electric system load diagram, and thus to the transfer from continuous operation of the water power station to semi-peak or even peak performance. According to the standards of power station classification, the Trencin water power station is a medium size, low pressure, channel power station with two units equipped by Kaplan turbines and synchronous hydro-alternators. The water power station installed capacity is 16.1 MW in total and its designed annual production of electrical energy for medium water year is 85,000 MWh, while the average annual production during the last 30 years is 86,252 MWh. Installed unit has a four-blade Kaplan turbine with the diameter

  19. Tether applications for space station

    Science.gov (United States)

    Nobles, W.

    1986-01-01

    A wide variety of space station applications for tethers were reviewed. Many will affect the operation of the station itself while others are in the category of research or scientific platforms. One of the most expensive aspects of operating the space station will be the continuing shuttle traffic to transport logistic supplies and payloads to the space station. If a means can be found to use tethers to improve the efficiency of that transportation operation, it will increase the operating efficiency of the system and reduce the overall cost of the space station. The concept studied consists of using a tether to lower the shuttle from the space station. This results in a transfer of angular momentum and energy from the orbiter to the space station. The consequences of this transfer is studied and how beneficial use can be made of it.

  20. Observation of very low frequency emissions at Indian Antarctic ...

    Indian Academy of Sciences (India)

    Recently, we have succeeded in recording VLF emissions at the Indian Antarctic station, Maitri (geom. lat. 62° S, geom. long. 57.23°E, =4.5) using a T-type antenna, pre/main amplifiers and digital audio tape recorder. VLF hiss in the frequency ranges 11–13 kHz and 13–14.5 kHz and some riser-type emissions in the ...

  1. Quantification of uncertainties in source term estimates for a BWR with Mark I containment

    International Nuclear Information System (INIS)

    Khatib-Rahbar, M.; Cazzoli, E.; Davis, R.; Ishigami, T.; Lee, M.; Nourbakhsh, H.; Schmidt, E.; Unwin, S.

    1988-01-01

    A methodology for quantification and uncertainty analysis of source terms for severe accident in light water reactors (QUASAR) has been developed. The objectives of the QUASAR program are (1) to develop a framework for performing an uncertainty evaluation of the input parameters of the phenomenological models used in the Source Term Code Package (STCP), and (2) to quantify the uncertainties in certain phenomenological aspects of source terms (that are not modeled by STCP) using state-of-the-art methods. The QUASAR methodology consists of (1) screening sensitivity analysis, where the most sensitive input variables are selected for detailed uncertainty analysis, (2) uncertainty analysis, where probability density functions (PDFs) are established for the parameters identified by the screening stage and propagated through the codes to obtain PDFs for the outputs (i.e., release fractions to the environment), and (3) distribution sensitivity analysis, which is performed to determine the sensitivity of the output PDFs to the input PDFs. In this paper attention is limited to a single accident progression sequence, namely; a station blackout accident in a BWR with a Mark I containment buildings. Identified as an important accident in the draft NUREG-1150 a station blackout involves loss of both off-site power and DC power resulting in failure of the diesels to start and in the unavailability of the high pressure injection and core isolation coding systems

  2. GSM base station electromagnetic radiation and oxidative stress in rats.

    Science.gov (United States)

    Yurekli, Ali Ihsan; Ozkan, Mehmed; Kalkan, Tunaya; Saybasili, Hale; Tuncel, Handan; Atukeren, Pinar; Gumustas, Koray; Seker, Selim

    2006-01-01

    The ever increasing use of cellular phones and the increasing number of associated base stations are becoming a widespread source of nonionizing electromagnetic radiation. Some biological effects are likely to occur even at low-level EM fields. In this study, a gigahertz transverse electromagnetic (GTEM) cell was used as an exposure environment for plane wave conditions of far-field free space EM field propagation at the GSM base transceiver station (BTS) frequency of 945 MHz, and effects on oxidative stress in rats were investigated. When EM fields at a power density of 3.67 W/m2 (specific absorption rate = 11.3 mW/kg), which is well below current exposure limits, were applied, MDA (malondialdehyde) level was found to increase and GSH (reduced glutathione) concentration was found to decrease significantly (p < 0.0001). Additionally, there was a less significant (p = 0.0190) increase in SOD (superoxide dismutase) activity under EM exposure.

  3. Electric Vehicle Fast-Charging Station Unified Modeling and Stability Analysis in the dq Frame

    Directory of Open Access Journals (Sweden)

    Xiang Wang

    2018-05-01

    Full Text Available The electric vehicle fast-charging station is an important guarantee for the popularity of electric vehicle. As the fast-charging piles are voltage source converters, stability issues will occur in the grid-connected fast-charging station. Since the dynamic input admittance of the fast-charging pile and the dynamic output impedance play an important role in the interaction system stability, the station and grid interaction system is regarded as load-side and source-side sub-systems to build the dynamic impedance model. The dynamic input admittance in matrix form is derived from the fast-charging pile current control loop considering the influence of the LC filter. Similarly, the dynamic output impedance can be obtained similarly by considering the regional power grid capacity, transformer capacity, and feed line length. On this basis, a modified forbidden region-based stability criterion is used for the fast-charging station stability analysis. The frequency-domain case studies and time-domain simulations are presented next to show the influence of factors from both the power grid side and fast-charging pile side. The simulation results validated the effectiveness of the dq frame impedance model and the stability analysis method.

  4. Mobile environmental radiation monitoring station

    International Nuclear Information System (INIS)

    Assido, H.; Shemesh, Y.; Mazor, T.; Tal, N.; Barak, D.

    1997-01-01

    A mobile environmental radiation monitoring station has been developed and established for the Israeli Ministry of Environment. The radiation monitoring station is ready for immediate placing in any required location, or can be operated from a vehicle. The station collects data Tom the detector and transfers it via cellular communication network to a Computerized Control Center for data storage, processing, and display . The mobile station is fully controlled from the. Routinely, the mobile station responses to the data request accumulated since the last communication session. In case of fault or alarm condition in the mobile station, a local claim is activated and immediately initiates communication with the via cellular communication network. (authors)

  5. Public safety assessment of electromagnetic radiation exposure from mobile base stations.

    Science.gov (United States)

    Alhekail, Z O; Hadi, M A; Alkanhal, M A

    2012-09-01

    Exposure of the general public to electromagnetic radiation originating from randomly selected GSM/WCDMA base stations in Riyadh, Kingdom of Saudi Arabia has been assessed in the context of the International Commission on Non-Ionising Radiation Protection (ICNIRP) guidelines. The purpose of the measurement was to record the maximum power density of signals to estimate possible worst case exposure at each measurement location. These power density measurements were carried out at 60 mobile base stations located in different regions of the city. For each of these sites, three sectors were operational, yielding a total of 180 sectors. Two positions were identified per site with the greatest power density values. Exposures from these base stations were generally found to be in the range of 0.313 to 0.00000149% of the ICNIRP general public reference level, and the greatest exposure near any of the base stations was 21.96 mW m(-2) for a wideband measurement in the 75-3000 MHz frequency range. Analysis of the measured data reveals several trends for different mobile bands with respect to maximum exposure in those locations. Additionally, a simplified calculation method for the electromagnetic fields was used to compare calculated and the measured data. It was determined, on the basis of both results of the measurements and calculations carried out for these selected base stations, that members of the public would not be exposed to in excess of a small fraction of the ICNIRP guidelines at any of those sites. These are first such measurements to be made in the Middle East and provide assurance that exposures in this region of the world do not seem to be any greater than elsewhere.

  6. High frequency microseismic noise as possible earthquake precursor

    OpenAIRE

    Ivica Sović; Kristina Šariri; Mladen Živčić

    2013-01-01

    Before an earthquake occurs, microseismic noise in high frequency (HF) range, i.e. 2-25 Hz, is being generated during preparation process. These signals change the microseismic noise and, consequently, the spectrum of microseismic noise. Time variation of spectra recorded at the same seismological station could imply the change of the state of noise source. We propose the image moment analysis approach to objectively compare microseismic noise spectra. The result could be used for earthquake ...

  7. the Preliminary Research Based on Seismic Signals Generated by Hutubi Transmitting Seismic Station with One Large-volume Airgun Array

    Science.gov (United States)

    Wang, Q.; Su, J.; Wei, Y.; Zhang, W.; Wang, H.; Wang, B.; Ji, Z.

    2017-12-01

    For studying the subsurface structure and its subtle changes, we built the Hutubi transmitting seismic station with one large-volume airgun array at one artificial water pool in the northern segment of Tianshan mountain, where earthquakes occurred frequently. The airgun array consists of six airguns with every airgun capacity of 2000in3, and the artificial water pool with the top diameter of 100m, bottom diameter of 20m and the depth of 18m.We started the regular excitation experiment with the large-volume airgun source every week since June, 2013. Using seismic signals geneated by the Hutubi airgun source, we made the preliminary research on the airgun source, waveform characteristics and the subsurface velocity changes in the northern Tiansh mountain. The results are as follows: The seismic signal exited by the airgun source is characteristic of low-frequency ,and the dominant frequency is in the range of 2 6Hz. The Hutubi transmitting seismic station can continuously generate long-distance detectable and highly repeatable signals, and the correlation coefficient of sigals is greater than 0.95; and the longest propagation distance arrives to 380km, in addition, the 5000-shot stacked sigal using the phase weighted stack technique can be identified in the station, which is about 1300km from the Hutubi transmitting seismic station. Hutubi large-volume airgun source is fitted to detect and monitor the regional-scale subsurface stress state. Applying correlation test method, we measured weak subsurface velocity changes in the northern Tianshan mountain, and found that the several stations, which are within 150km from the the Hutubi transmitting seismic station, appeared 0.1 0.2% relative velocity changes before the Hutubi MS6.2 earthquake on Dec.8, 2016.

  8. CDIP Station Data Collection - All Stations

    Data.gov (United States)

    Scripps Institution of Oceanography, UC San Diego — The Coastal Data Information Program's station data collection consists of all publicly-released coastal environment measurements taken over the program's history, a...

  9. Influences on flood frequency distributions in Irish river catchments

    Directory of Open Access Journals (Sweden)

    S. Ahilan

    2012-04-01

    Full Text Available This study explores influences on flood frequency distributions in Irish rivers. A Generalised Extreme Value (GEV type I distribution is recommended in Ireland for estimating flood quantiles in a single site flood frequency analysis. This paper presents the findings of an investigation that identified the GEV statistical distributions that best fit the annual maximum (AM data series extracted from 172 gauging stations of 126 rivers in Ireland. Analysis of these data was undertaken to explore hydraulic and hydro-geological factors that influence flood frequency distributions. A hierarchical approach of increasing statistical power that used probability plots, moment and L-moment diagrams, the Hosking goodness of fit algorithm and a modified Anderson-Darling (A-D statistical test was followed to determine whether a type I, type II or type III distribution was valid. Results of the Hosking et al. method indicated that of the 143 stations with flow records exceeding 25 yr, data for 95 (67% was best represented by GEV type I distributions and a further 9 (6% and 39 (27% stations followed type II and type III distributions respectively. Type I, type II and type III distributions were determined for 83 (58%, 16 (11% and 34 (24% stations respectively using the modified A-D method (data from 10 stations was not represented by GEV family distributions. The influence of karst terrain on these flood frequency distributions was assessed by incorporating results on an Arc-GIS platform showing karst features and using Monte Carlo simulations to assess the significance of the number and clustering of the observed distributions. Floodplain effects were identified by using two-sample t-tests to identify statistical correlations between the distributions and catchment properties that are indicative of strong floodplain activity. The data reveals that type I distributions are spatially well represented throughout the country. While also well represented throughout

  10. A customer-friendly Space Station

    Science.gov (United States)

    Pivirotto, D. S.

    1984-01-01

    This paper discusses the relationship of customers to the Space Station Program currently being defined by NASA. Emphasis is on definition of the Program such that the Space Station will be conducive to use by customers, that is by people who utilize the services provided by the Space Station and its associated platforms and vehicles. Potential types of customers are identified. Scenarios are developed for ways in which different types of customers can utilize the Space Station. Both management and technical issues involved in making the Station 'customer friendly' are discussed.

  11. Experimental and Theoretical Dynamic Study of the Aagesta Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Bliselius, P A; Vollmer, H; Aakerhielm, F

    1969-12-15

    The report presents a final review and summary of all dynamic investigations of the Aagesta nuclear power station. Special attention is paid to the final and unpublished experiments performed in 1965-66. These experiments are discussed and compared to the theoretical predictions. Transfer functions and step responses were measured by perturbations in reactivity and steam load. Three methods were used for transfer function measurements: step functions, trapeze waves and multifrequency functions based on the pseudo-random binary sequence (PRBS). From the frequency analysis we found that the different perturbation methods led to quite consistent results. For the Agesta application the PRBS method is demonstrated to be an accurate and practical method for obtaining experimental transfer functions. The step technique did not give satisfactory results for frequencies above approximately 0.01 Hz. From the static check of the model we may conclude that the experiments agree fairly well mutually and with theory. The measured reactivity coefficients tend to be smaller than the predicted ones. The predicted transients compare well with the measured ones. However, there is a tendency to more peaked power transients from the model. This is believed to be due to the assumption that the moderator could be regarded as one channel. The dynamic experiments carried out at the Agesta nuclear power station demonstrate both the inherent stability and the safety of this plant.

  12. The Miksova water power station

    International Nuclear Information System (INIS)

    2005-01-01

    This leaflet describes the Miksova water power station. The Miksova water power station is part of the second derived cascade of hydro power stations on the river Vah. It was built at the end of a huge development in Slovak hydro-energy in the late 1950's and the beginning of the 1960's. It is the second water power station on this derived cascade, which is situated downstream the Hricov reservoir and water power station. At the power station, three turbine sets with vertical Kaplan turbines are installed with a total power output of 3 x 31.2 = 93.6 MW. With this power output the Miksova water power station (Miksova I) was the biggest water power station in the Slovak Republic until the construction of Pumping water power station Liptovska Mara. And it is still the biggest channel water power station on the Vah so far. It was put into operation during the period 1963 to 1965. There are three turbine sets with Kaplan turbines from CKD Blansko, with a synchronous hydro-alternator installed in the power station. Their installed capacity is 93.6 MW in total and the projected annual production of electrical energy is 207 GWh. The turbines are fi ve-bladed (on the Hricov and Povazska Bystrica water power stations they are four-bladed) and the impeller wheel has a diameter of 4800 mm. They are designed for extension of the head from 24.1 to 22.21 m and each of them has an absorption capacity of 134 m 3 .s -1 nd a nominal operating speed of 2.08 m 3 .s -1 , runaway speed 4.9 m 3 .s -1 . Each synchronous hydro-alternator has a maximum power output of 31.2 MW, a nominal voltage of 10.5 kV and power factor cos φ of 0.8. Power from the power station is led out through 110 kV switchgear. The water power station operates under automatic turbine mode of operation with remote indication and control from the Dispatch Centre at Vodne elektrarne, in Trencin. From start of operation until the end of 2003 all three turbine sets operated for a total of 450,500 running hours and the

  13. Implementation and Demonstration of Grid Frequency Support by V2G Enabled Electric Vehicle

    DEFF Research Database (Denmark)

    Martinenas, Sergejus; Marinelli, Mattia; Andersen, Peter Bach

    2014-01-01

    Safe operation of the electric power system relies on conventional power stations. In addition to providing electrical energy to the network, some power stations also provide a number of ancillary services for the grid stability. These services could potentially be provided by the growing number...... Frequency Regulation. The service is implemented following the technical conditions for ancillary services in the Danish grid. The real life system is developed using web-centric communication technologies between the components. Communication and control functions of the system are validated through...

  14. Space station propulsion requirements study

    Science.gov (United States)

    Wilkinson, C. L.; Brennan, S. M.

    1985-01-01

    Propulsion system requirements to support Low Earth Orbit (LEO) manned space station development and evolution over a wide range of potential capabilities and for a variety of STS servicing and space station operating strategies are described. The term space station and the overall space station configuration refers, for the purpose of this report, to a group of potential LEO spacecraft that support the overall space station mission. The group consisted of the central space station at 28.5 deg or 90 deg inclinations, unmanned free-flying spacecraft that are both tethered and untethered, a short-range servicing vehicle, and a longer range servicing vehicle capable of GEO payload transfer. The time phasing for preferred propulsion technology approaches is also investigated, as well as the high-leverage, state-of-the-art advancements needed, and the qualitative and quantitative benefits of these advancements on STS/space station operations. The time frame of propulsion technologies applicable to this study is the early 1990's to approximately the year 2000.

  15. A FMM-FFT accelerated hybrid volume surface integral equation solver for electromagnetic analysis of re-entry space vehicles

    KAUST Repository

    Yücel, Abdulkadir C.

    2014-07-01

    Space vehicles that re-enter the atmosphere often experience communication blackout. The blackout occurs when the vehicle becomes engulfed in plasma produced by interactions between the vehicle surface and the atmosphere. The plasma often is concentrated in a relatively thin shell around the vehicle, with higher densities near its nose than rear. A less structured, sometimes turbulent plasma wake often trails the vehicle. The plasma shell severely affects the performance of side-mounted antennas as it alters their characteristics (frequency response, gain patterns, axial ratio, and impedance) away from nominal, free-space values, sometimes entirely shielding the antenna from the outside world. The plasma plume/turbulent wake similarly affect the performance of antennas mounted at the back of the vehicle. The electromagnetic characteristics of the thin plasma shell and plume/turbulent wake heavily depend on the type of re-entry trajectory, the vehicle\\'s speed, angles of attack, and chemical composition, as well as environmental conditions. To analyze the antennas\\' performance during blackout and to design robust communication antennas, efficient and accurate simulation tools for charactering the antennas\\' performance along the trajectory are called for.

  16. Hydrogen Station Cost Estimates: Comparing Hydrogen Station Cost Calculator Results with other Recent Estimates

    Energy Technology Data Exchange (ETDEWEB)

    Melaina, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Penev, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-09-01

    This report compares hydrogen station cost estimates conveyed by expert stakeholders through the Hydrogen Station Cost Calculation (HSCC) to a select number of other cost estimates. These other cost estimates include projections based upon cost models and costs associated with recently funded stations.

  17. Studies of Geomagnetic Pulsations Using Magnetometer Data from the CHAMP Low-Earth-Orbit Satellite and Ground-Based Stations: a Review

    Directory of Open Access Journals (Sweden)

    P R Sutcliffe

    2011-06-01

    Full Text Available We review research on geomagnetic pulsations carried out using magnetic field measurements from the CHAMP low-Earth-orbit (LEO satellite and ground-based stations in South Africa and Hungary. The high quality magnetic field measurements from CHAMP made it possible to extract and clearly resolve Pi2 and Pc3 pulsations in LEO satellite data. Our analyses for nighttime Pi2 pulsations are indicative of a cavity mode resonance. However, observations of daytime Pi2 pulsation events identified in ground station data show no convincing evidence of their occurrence in CHAMP data. We also studied low-latitude Pc3 pulsations and found that different types of field line resonant structure occur, namely discrete frequencies driven by a narrow band source and L-dependent frequencies driven by a broad band source.

  18. Electromagnetic fields from mobile phone base station - variability analysis.

    Science.gov (United States)

    Bienkowski, Pawel; Zubrzak, Bartlomiej

    2015-09-01

    The article describes the character of electromagnetic field (EMF) in mobile phone base station (BS) surroundings and its variability in time with an emphasis on the measurement difficulties related to its pulse and multi-frequency nature. Work also presents long-term monitoring measurements performed recently in different locations in Poland - small city with dispersed building development and in major polish city - dense urban area. Authors tried to determine the trends in changing of EMF spectrum analyzing daily changes of measured EMF levels in those locations. Research was performed using selective electromagnetic meters and also EMF meter with spectrum analysis.

  19. Power and performance. Y2K challenges for electricity grids in Eastern Europe

    International Nuclear Information System (INIS)

    Kossilov, A.; Gueorguiev, B.; Ianev, I.; Purvis, E.

    1999-01-01

    The Year 2000 problem can directly affect the safety of nuclear power plants through interfaces with electric power and telecommunication systems. Recently, probabilistic safety assessments have made it clear that a 'station blackout' at a nuclear power plant is a major contributor to the sequence of events that could cause severe accidents. Within the IAEA actions concerned with Y2K problem, particular focus was on countries in eastern Europe, where here were delays in taking Y2K corrective actions

  20. Gas Stations, US, 2010, NAVTEQ

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Gas_Stations dataset is derived from the Navteq 'AUTOSVC' SDC layer (FAC_TYPE=5540) and contains gas stations and petrol stations. This NAVTEQ dataset is...

  1. Non-Coop Station History (Unindexed)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Station history documentation for stations outside the US Cooperative Observer network. Documents should be compared with those in the Non-Coop Station History...

  2. Indicators to assess the environmental performances of an innovative subway station : example of Noisy-Champs

    Science.gov (United States)

    Schertzer, D. J. M.; Charbonnier, L.; Versini, P. A.; Tchiguirinskaia, I.

    2017-12-01

    Noisy-Champs is a train station located in Noisy-le-Grand and Champs-sur-Marne, in the Paris urban area (France). Integrated into the Grand Paris Express project (huge development project to modernise the transport network around Paris), this station is going to be radically transformed and become a major hub. Designed by the architectural office Duthilleul, the new Noisy-Champs station aspires to be an example of an innovative and sustainable infrastructure. Its architectural precepts are indeed meant to improve its environmental performances, especially those related to storm water management, water consumption and users' thermal and hygrometric comfort. In order to assess and monitor these performances, objectives and associated indicators have been developed. They aim to be adapted for a specific infrastructure such as a public transport station. Analyses of pre-existing comfort simulations, blueprints and regulatory documents have led to identify the main issues for the Noisy-Champs station, focusing on its resilience to extreme events like droughts, heatwaves and heaxvy rainfalls. Both objectives and indicators have been proposed by studying the space-time variabilities of physical fluxes (heat, pollutants, radiation, wind and water) and passenger flows, and their interactions. Each indicator is linked to an environmental performance and has been determined after consultation of the different stakeholders involved in the rebuilding of the station. It results a monitoring program to assess the environmental performances of the station composed by both the indicators grid and their related objectives, and a measurement program detailing the nature and location of sensors, and the frequency of measurements.

  3. Single-Station Sigma for the Iranian Strong Motion Stations

    Science.gov (United States)

    Zafarani, H.; Soghrat, M. R.

    2017-11-01

    In development of ground motion prediction equations (GMPEs), the residuals are assumed to have a log-normal distribution with a zero mean and a standard deviation, designated as sigma. Sigma has significant effect on evaluation of seismic hazard for designing important infrastructures such as nuclear power plants and dams. Both aleatory and epistemic uncertainties are involved in the sigma parameter. However, ground-motion observations over long time periods are not available at specific sites and the GMPEs have been derived using observed data from multiple sites for a small number of well-recorded earthquakes. Therefore, sigma is dominantly related to the statistics of the spatial variability of ground motion instead of temporal variability at a single point (ergodic assumption). The main purpose of this study is to reduce the variability of the residuals so as to handle it as epistemic uncertainty. In this regard, it is tried to partially apply the non-ergodic assumption by removing repeatable site effects from total variability of six GMPEs driven from the local, Europe-Middle East and worldwide data. For this purpose, we used 1837 acceleration time histories from 374 shallow earthquakes with moment magnitudes ranging from M w 4.0 to 7.3 recorded at 370 stations with at least two recordings per station. According to estimated single-station sigma for the Iranian strong motion stations, the ratio of event-corrected single-station standard deviation ( Φ ss) to within-event standard deviation ( Φ) is about 0.75. In other words, removing the ergodic assumption on site response resulted in 25% reduction of the within-event standard deviation that reduced the total standard deviation by about 15%.

  4. Central Station Design Options

    DEFF Research Database (Denmark)

    2011-01-01

    . The work identifies the architecture, sizing and siting of prospective Central Stations in Denmark, which can be located at shopping centers, large car parking lots or gas stations. Central Stations are planned to be integrated in the Danish distribution grid. The Danish island of Bornholm, where a high...... overloading, more reference points might be necessary to represent various transformer loading levels. The subject of safety in Central Station is also addressed. A number of safety rules based on European standards apply to AC charging equipment up to 44 kW. The connection interlock and the automatic de......-energization are identified as fundamental requirements for safety in such a charging station. The connection interlock is a solution which ensures that no power is applied to the DC cable when the EV connector is not connected. The automatic de-energization device ensures that whenever a strain on the cable is detected, e...

  5. Enhanced Master Station History Report

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Enhanced Master Station History Report (EMSHR) is a compiled list of basic, historical information for every station in the station history database, beginning...

  6. SPS rectifier stations

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The first of the twelves SPS rectifier stations for the bending magnets arrived at CERN at the end of the year. The photograph shows a station with the rectifiers on the left and in the other three cubicles the chokes, capacitors and resistor of the passive filter.

  7. 47 CFR 97.109 - Station control.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Station control. 97.109 Section 97.109... SERVICE Station Operation Standards § 97.109 Station control. (a) Each amateur station must have at least one control point. (b) When a station is being locally controlled, the control operator must be at the...

  8. Microwave Frequency Multiplier

    Science.gov (United States)

    Velazco, J. E.

    2017-02-01

    High-power microwave radiation is used in the Deep Space Network (DSN) and Goldstone Solar System Radar (GSSR) for uplink communications with spacecraft and for monitoring asteroids and space debris, respectively. Intense X-band (7.1 to 8.6 GHz) microwave signals are produced for these applications via klystron and traveling-wave microwave vacuum tubes. In order to achieve higher data rate communications with spacecraft, the DSN is planning to gradually furnish several of its deep space stations with uplink systems that employ Ka-band (34-GHz) radiation. Also, the next generation of planetary radar, such as Ka-Band Objects Observation and Monitoring (KaBOOM), is considering frequencies in the Ka-band range (34 to 36 GHz) in order to achieve higher target resolution. Current commercial Ka-band sources are limited to power levels that range from hundreds of watts up to a kilowatt and, at the high-power end, tend to suffer from poor reliability. In either case, there is a clear need for stable Ka-band sources that can produce kilowatts of power with high reliability. In this article, we present a new concept for high-power, high-frequency generation (including Ka-band) that we refer to as the microwave frequency multiplier (MFM). The MFM is a two-cavity vacuum tube concept where low-frequency (2 to 8 GHz) power is fed into the input cavity to modulate and accelerate an electron beam. In the second cavity, the modulated electron beam excites and amplifies high-power microwaves at a frequency that is a multiple integer of the input cavity's frequency. Frequency multiplication factors in the 4 to 10 range are being considered for the current application, although higher multiplication factors are feasible. This novel beam-wave interaction allows the MFM to produce high-power, high-frequency radiation with high efficiency. A key feature of the MFM is that it uses significantly larger cavities than its klystron counterparts, thus greatly reducing power density and arcing

  9. Power station instrumentation

    International Nuclear Information System (INIS)

    Jervis, M.W.

    1993-01-01

    Power stations are characterized by a wide variety of mechanical and electrical plant operating with structures, liquids and gases working at high pressures and temperatures and with large mass flows. The voltages and currents are also the highest that occur in most industries. In order to achieve maximum economy, the plant is operated with relatively small margins from conditions that can cause rapid plant damage, safety implications, and very high financial penalties. In common with other process industries, power stations depend heavily on control and instrumentation. These systems have become particularly significant, in the cost-conscious privatized environment, for providing the means to implement the automation implicit in maintaining safety standards, improving generation efficiency and reducing operating manpower costs. This book is for professional instrumentation engineers who need to known about their use in power stations and power station engineers requiring information about the principles and choice of instrumentation available. There are 8 chapters; chapter 4 on instrumentation for nuclear steam supply systems is indexed separately. (Author)

  10. Phytotoxicology section investigation in the vicinity of the Bruce Nuclear Power Development, the Pickering Nuclear Generating Station and the Darlington Nuclear Generating Station, in October, 1989

    International Nuclear Information System (INIS)

    1991-02-01

    The Phytotoxicology Section, Air Resources Branch is a participant in the Pickering and Bruce Nuclear Contingency Plans. The Phytotoxicology Emergency Response Team is responsible for collecting vegetation samples in the event of a nuclear emergency at any of the nuclear generating stations in the province. As part of its responsibility the Phytotoxicology Section collects samples around the nuclear generating stations for comparison purposes in the event of an emergency. Because of the limited frequency of sampling, the data from the surveys are not intended to be used as part of a regulatory monitoring program. These data represent an effort by the MOE to begin to establish a data base of tritium concentrations in vegetation. The Phytotoxicology Section has carried out seven surveys in the vicinity of Ontario Hydro nuclear generating stations since 1981. Surveys were conducted for tritium in snow in the vicinity of Bruce Nuclear Power Development (BNPD), February, 1981; tritium in cell-free water of white ash in the vicinity of BNPD, September, 1981; tritium in snow in the vicinity of BNPD, March, 1982; tritium in tree sap in the vicinity of BNPD, April, 1982; tritium in tree sap in the vicinity of BNPD, April, 1984, tritium in the cell-free water of white ash in the vicinity of BNPD, September, 1985; and, tritium in cell-free water of grass in the vicinity of Pickering Nuclear Generation Station (PNGS), October 1986. In all cases a pattern of decreasing tritium levels with increasing distance from the stations was observed. In October, 1989, assessment surveys were conducted around Bruce Nuclear Power Development, the Pickering Nuclear Generating Station and the new Darlington Nuclear Generating Station (DNGS). The purpose of these surveys was to provide baseline data for tritium in cell-free water of grass at all three locations at the same time of year. As none of the reactor units at DNGS had been brought on line at the time of the survey, this data was to be

  11. Station Capacity

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    the probability of conflicts and the minimum headway times into account. The last method analyzes how optimal platform tracks are used by examining the arrival and departure pattern of the trains. The developed methods can either be used separately to analyze specific characteristics of the capacity of a station......Stations are often limiting the capacity of railway networks. This is due to extra need of tracks when trains stand still, trains turning around, and conflicting train routes. Although stations are often the capacity bottlenecks, most capacity analysis methods focus on open line capacity. Therefore...... for platform tracks and the probability that arriving trains will not get a platform track immediately at arrival. The third method is a scalable method that analyzes the conflicts in the switch zone(s). In its simplest stage, the method just analyzes the track layout while the more advanced stages also take...

  12. Secure base stations

    NARCIS (Netherlands)

    Bosch, Peter; Brusilovsky, Alec; McLellan, Rae; Mullender, Sape J.; Polakos, Paul

    2009-01-01

    With the introduction of the third generation (3G) Universal Mobile Telecommunications System (UMTS) base station router (BSR) and fourth generation (4G) base stations, such as the 3rd Generation Partnership Project (3GPP) Long Term Evolution (LTE) Evolved Node B (eNB), it has become important to

  13. Data communications method for mobile network in fourth generation communications system, involves delivering decoded data to mobile station from relay station, where mobile station receives data from both relay and base stations

    DEFF Research Database (Denmark)

    2008-01-01

    The method involves utilizing a base station (BS) (100) to transmit data to a relay station (RS) (110) and a mobile station (MS) (120), where the data includes two messages. The BS is utilized to transmit the two messages by utilizing a linear combination method, and the data is received in the RS...

  14. Metabolic Polymorphisms and Clinical Findings Related to Benzene Poisoning Detected in Exposed Brazilian Gas-Station Workers

    Directory of Open Access Journals (Sweden)

    Simone Mitri

    2015-07-01

    Full Text Available Benzene is a ubiquitous environmental pollutant and an important industrial chemical present in both gasoline and motor vehicle emissions. Occupational human exposure to benzene occurs in the petrochemical and petroleum refining industries as well as in gas-station workers, where it can lead to benzene poisoning (BP, but the mechanisms of BP are not completely understood. In Brazil, a significant number of gas-station service workers are employed. The aim of the present study was to evaluate alterations related to BP and metabolic polymorphisms in gas-station service workers exposed to benzene in the city of Rio de Janeiro, Brazil. Occupational exposure was based on clinical findings related to BP, and metabolic polymorphisms in 114 Brazilian gas-station attendants. These workers were divided into No Clinical Findings (NCF and Clinical Findings (CF groups. Neutrophil and Mean Corpuscular Volume (MCV showed a significant difference between the two study groups, and neutrophil has the greatest impact on the alterations suggestive of BP. The clinical findings revealed higher frequencies of symptoms in the CF group, although not all members presented statistical significance. The frequencies of alleles related to risk were higher in the CF group for GSTM1, GSTT1, CYP2E1 7632T > A, but lower for NQO1 and CYP2E1 1053C > T genotypes. Moreover, an association was found between GSTM1 null and alterations related to BP, but we did not observe any effects of other polymorphisms. Variations in benzene metabolizing genes may modify benzene toxicity and should be taken into consideration during risk assessment evaluations.

  15. Crustal structure beneath two seismic stations in the Sunda-Banda arc transition zone derived from receiver function analysis

    Energy Technology Data Exchange (ETDEWEB)

    Syuhada, E-mail: hadda9@gmail.com [Graduate Research on Earthquake and Active Tectonics (GREAT), Bandung Institute of Technology, Jalan Ganesha 10, Bandung 40132 (Indonesia); Research Centre for Physics - Indonesian Institute of Sciences (LIPI), Kompleks Puspiptek Serpong, Tangsel 15314, Banten Indonesia (Indonesia); Hananto, Nugroho D.; Handayani, Lina [Research Centre for Geotechnology - Indonesian Institute of Sciences (LIPI), Jl. Sangkuriang (Kompleks LIPI) Bandung 40135 (Indonesia); Puspito, Nanang T; Yudistira, Tedi [Faculty of Mining and Petroleum Engineering ITB, Jalan Ganesha 10, Bandung 40132 (Indonesia); Anggono, Titi [Research Centre for Physics - Indonesian Institute of Sciences (LIPI), Kompleks Puspiptek Serpong, Tangsel 15314, Banten Indonesia (Indonesia)

    2015-04-24

    We analyzed receiver functions to estimate the crustal thickness and velocity structure beneath two stations of Geofon (GE) network in the Sunda-Banda arc transition zone. The stations are located in two different tectonic regimes: Sumbawa Island (station PLAI) and Timor Island (station SOEI) representing the oceanic and continental characters, respectively. We analyzed teleseismic events of 80 earthquakes to calculate the receiver functions using the time-domain iterative deconvolution technique. We employed 2D grid search (H-κ) algorithm based on the Moho interaction phases to estimate crustal thickness and Vp/Vs ratio. We also derived the S-wave velocity variation with depth beneath both stations by inverting the receiver functions. We obtained that beneath station PLAI the crustal thickness is about 27.8 km with Vp/Vs ratio 2.01. As station SOEI is covered by very thick low-velocity sediment causing unstable solution for the inversion, we modified the initial velocity model by adding the sediment thickness estimated using high frequency content of receiver functions in H-κ stacking process. We obtained the crustal thickness is about 37 km with VP/Vs ratio 2.2 beneath station SOEI. We suggest that the high Vp/Vs in station PLAI may indicate the presence of fluid ascending from the subducted plate to the volcanic arc, whereas the high Vp/Vs in station SOEI could be due to the presence of sediment and rich mafic composition in the upper crust and possibly related to the serpentinization process in the lower crust. We also suggest that the difference in velocity models and crustal thicknesses between stations PLAI and SOEI are consistent with their contrasting tectonic environments.

  16. Waste Transfer Stations

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund

    2011-01-01

    tion and transport is usually the most costly part of any waste management system; and when waste is transported over a considerable distance or for a long time, transferring the waste from the collection vehicles to more efficient transportation may be economically beneficial. This involves...... a transfer station where the transfer takes place. These stations may also be accessible by private people, offering flexibility to the waste system, including facilities for bulky waste, household hazardous waste and recyclables. Waste transfer may also take place on the collection route from small...... describes the main features of waste transfer stations, including some considerations about the economical aspects on when transfer is advisable....

  17. Variability of critical frequency and M(3000)F2 at Tucuman and San Juan

    International Nuclear Information System (INIS)

    Ezquer, R.G.; Mosert, M.; Corbella, R.J.

    2002-01-01

    The variability of the M(3000)F2 factor and the critical frequency of the E and F2 ionospheric regions over two argentine stations for middle solar activity conditions is studied. To this end different parameters to specify variability are used, namely: standard deviation, difference between median to lower quartile and to upper quartile. The results show that low variability is observed for foE and M(3000)F2 factor at both stations for equinoxes and solstices. The coefficients of variability are lower than 10% for foE and M(3000)F2 factor. The highest variability was observed for foF2. In general, the foF2 coefficient of variability ranges between 0 and 30%, at both stations. (author)

  18. Meyrin Petrol Station

    CERN Multimedia

    2006-01-01

    Please note that the Meyrin petrol station will be closed for maintenance work on Tuesday 19 and Wednesday 20 December 2006. If you require petrol during this period we invite you to use the Prévessin petrol station, which will remain open. TS-IC-LO Section Tel.: 77039 - 73793

  19. Multiuser Carrier Frequency Offset Estimation for OFDMA Uplink Based on Multi-Antenna

    Science.gov (United States)

    Zhang, Weile; Wang, Junsong; Yin, Qinye; Feng, Ang

    In this letter, a novel method is proposed for carrier-frequency offset (CFO) estimation for multiple users in orthogonal frequency division multiple access (OFDMA) uplink with the generalized carrier assignment scheme (GCAS). The base station (BS) is equipped with multiple antennas, and each user's CFO can be estimated by the ESPRIT-like method that utilizes the rotation invariance of the space-domain snapshot matrix. The method is still effective even in fully loaded system with all subcarriers allocated to users. Simulation results illustrate the high performance of the proposed algorithm.

  20. Base Station Performance Model

    OpenAIRE

    Walsh, Barbara; Farrell, Ronan

    2005-01-01

    At present the testing of power amplifiers within base station transmitters is limited to testing at component level as opposed to testing at the system level. While the detection of catastrophic failure is possible, that of performance degradation is not. This paper proposes a base station model with respect to transmitter output power with the aim of introducing system level monitoring of the power amplifier behaviour within the base station. Our model reflects the expe...

  1. Variations of the ionization push frequency in the ASK-1 chamber

    International Nuclear Information System (INIS)

    Krivoshapkin, P.A.; Mamrukova, V.P.; Skripin, G.V.; Shafer, G.V.

    1997-01-01

    The data on frequency push in the ASK-1 chamber at the Yakutsk station for 1954-1994 are analyzed. The observed eleven-year and half-year push variations are related to the solar activity. The narrowly directed galactic anisotropy with 6-8 h direction, coinciding with the direction of the helio-magnetosphere tail, formed by the solar system motion relative to stars is identified in a daily motion by sidereal time. The great barometric and temperature coefficients of the frequency pushes are obtained. This indicates the prevailing role of the nuclear-active particles in formation of pushes

  2. Magnetic Base Station Deceptions, a magnetovariational analysis along the Ligurian Sea coast, Italy

    Directory of Open Access Journals (Sweden)

    E. Bozzo

    2007-06-01

    Full Text Available Reliability of high resolution airborne and shipborne magnetic surveys depends on accurate removal of temporal variations from the recorded total magnetic field intensity data. At mid latitudes, one or a few base stations are typically located within or near the survey area and are used to monitor and remove time dependent variations. These are usually assumed to be of external origin and uniform throughout the survey area. Here we investigate the influence on the magnetic base station correction of the time varying magnetic field variations generated by internal telluric currents flowing in anomalous regional 2D/3D conductivity structures. The study is based on the statistical analysis of a data set collected by four magnetovariational stations installed in northwestern Italy. The variometer stations were evenly placed with a spacing of about 60 km along a profile roughly parallel to the coastline. They recorded the geomagnetic field from the beginning to the end of April 2005, with a sampling rate of 0.33 Hz. Cross-correlation and coherence analysis applied to a subset of 125 five hours long magnetic events indicates that, for periods longer than 400 s, there is an high correlation between the horizontal magnetic field components at the different stations. This indicates spatial uniformity of the source field and of the induced currents in the 1D Earth. Additionally, the pattern of the induction arrows, estimated from single site transfer functions, reveals a clear electromagnetic signature of the Sestri-Voltaggio line, interpreted as a major regional tectonic boundary. Induced telluric currents flowing through this 2D/3D electrical conductivity discontinuity affect mainly the vertical magnetic component at the closer locations. By comparing this component at near (32 km and far (70 km stations, we have found that the mean value of the power spectra ratio, due to the electromagnetic induced field, is about 1.8 in the frequency

  3. Modelling precipitation extremes in the Czech Republic: update of intensity–duration–frequency curves

    Directory of Open Access Journals (Sweden)

    Michal Fusek

    2016-11-01

    Full Text Available Precipitation records from six stations of the Czech Hydrometeorological Institute were subject to statistical analysis with the objectives of updating the intensity–duration–frequency (IDF curves, by applying extreme value distributions, and comparing the updated curves against those produced by an empirical procedure in 1958. Another objective was to investigate differences between both sets of curves, which could be explained by such factors as different measuring instruments, measuring stations altitudes and data analysis methods. It has been shown that the differences between the two sets of IDF curves are significantly influenced by the chosen method of data analysis.

  4. Space Station fluid management logistics

    Science.gov (United States)

    Dominick, Sam M.

    1990-01-01

    Viewgraphs and discussion on space station fluid management logistics are presented. Topics covered include: fluid management logistics - issues for Space Station Freedom evolution; current fluid logistics approach; evolution of Space Station Freedom fluid resupply; launch vehicle evolution; ELV logistics system approach; logistics carrier configuration; expendable fluid/propellant carrier description; fluid carrier design concept; logistics carrier orbital operations; carrier operations at space station; summary/status of orbital fluid transfer techniques; Soviet progress tanker system; and Soviet propellant resupply system observations.

  5. Hammond Bay Biological Station

    Data.gov (United States)

    Federal Laboratory Consortium — Hammond Bay Biological Station (HBBS), located near Millersburg, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). HBBS was established by...

  6. 47 CFR 74.793 - Digital low power TV and TV translator station protection of broadcast stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital low power TV and TV translator station... DISTRIBUTIONAL SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.793 Digital low power TV and TV translator station protection of broadcast stations. (a) An application to construct a new digital low power...

  7. A Potential Transmitter Architecture for Future Generation Green Wireless Base Station

    Directory of Open Access Journals (Sweden)

    Mike Faulkner

    2009-01-01

    Full Text Available Current radio frequency power amplifiers in 3G base stations have very high power consumption leading to a hefty cost and negative environmental impact. In this paper, we propose a potential architecture design for future wireless base station. Issues associated with components of the architecture are investigated. The all-digital transmitter architecture uses a combination of envelope elimination and restoration (EER and pulse width modulation (PWM/pulse position modulation (PPM modulation. The performance of this architecture is predicted from the measured output power and efficiency curves of a GaN amplifier. 57% efficiency is obtained for an OFDM signal limited to 8 dB peak to average power ratio. The PWM/PPM drive signal is generated using the improved Cartesian sigma delta techniques. It is shown that an RF oversampling by a factor of four meets the WLAN spectral mask, and WCDMA specification is met by an RF oversampling of sixteen.

  8. Statistical analysis of midlatitude spread F using multi-station digisonde observations

    Science.gov (United States)

    Bhaneja, P.; Earle, G. D.; Bullett, T. W.

    2018-01-01

    A comprehensive statistical study of midlatitude spread F (MSF) is presented for five midlatitude stations in the North American sector. These stations include Ramey AFB, Puerto Rico (18.5°N, 67.1°W, -14° declination angle), Wallops Island, Virginia (37.95°N, 75.5°W, -11° declination angle), Dyess, Texas (32.4°N, 99.8°W, 6.9° declination angle), Boulder, Colorado (40°N, 105.3°W, 10° declination angle), and Vandenberg AFB, California (34.8°N, 120.5°W, 13° declination angle). Pattern recognition algorithms are used to determine the presence of both range and frequency spread F. Data from 1996 to 2011 are analyzed, covering all of Solar Cycle 23 and the beginning of Solar Cycle 24. Variations with respect to season and solar activity are presented, including the effects of the extended minimum between cycles 23 and 24.

  9. A Potential Transmitter Architecture for Future Generation Green Wireless Base Station

    Directory of Open Access Journals (Sweden)

    Cijvat Ellie

    2009-01-01

    Full Text Available Abstract Current radio frequency power amplifiers in 3G base stations have very high power consumption leading to a hefty cost and negative environmental impact. In this paper, we propose a potential architecture design for future wireless base station. Issues associated with components of the architecture are investigated. The all-digital transmitter architecture uses a combination of envelope elimination and restoration (EER and pulse width modulation (PWM/pulse position modulation (PPM modulation. The performance of this architecture is predicted from the measured output power and efficiency curves of a GaN amplifier. 57% efficiency is obtained for an OFDM signal limited to 8 dB peak to average power ratio. The PWM/PPM drive signal is generated using the improved Cartesian sigma delta techniques. It is shown that an RF oversampling by a factor of four meets the WLAN spectral mask, and WCDMA specification is met by an RF oversampling of sixteen.

  10. Big Game Reporting Stations

    Data.gov (United States)

    Vermont Center for Geographic Information — Point locations of big game reporting stations. Big game reporting stations are places where hunters can legally report harvested deer, bear, or turkey. These are...

  11. Weigh-in-Motion Stations

    Data.gov (United States)

    Department of Homeland Security — The data included in the GIS Traffic Stations Version database have been assimilated from station description files provided by FHWA for Weigh-in-Motion (WIM), and...

  12. Frequency scanning interferometry for CLIC component fiducialisation

    CERN Document Server

    Kamugasa, Solomon William; Mainaud Durand, Helene; CERN. Geneva. ATS Department

    2016-01-01

    We present a strategy for the fiducialisation of CLIC’s Main Beam Quadrupole (MBQ) magnets using Frequency Scanning Interferometry (FSI). We have developed complementary device for a commercial FSI system to enable coordinate determination via multilateration. Using spherical high index glass retroreflectors with a wide acceptance angle, we optimise the geometry of measurement stations with respect to fiducials -- thus improving the precision of coordinates. We demonstrate through simulations that the 10 μm uncertainty required in the vertical and lateral axes for the fiducialisation of the MBQ can be attained using FSI multilateration.

  13. Air and radiation monitoring stations

    CERN Multimedia

    AUTHOR|(SzGeCERN)582709

    2015-01-01

    CERN has around 100 monitoring stations on and around its sites. New radiation measuring stations, capable of detecting even lower levels of radiation, were installed in 2014. Two members of HE-SEE group (Safety Engineering and Environment group) in front of one of the new monitoring stations.

  14. Exposure to radio waves near mobile phone base stations

    International Nuclear Information System (INIS)

    Mann, S.M.; Cooper, T.G.; Allen, S.G.; Blackwell, R.P.; Lowe, A.J.

    2000-01-01

    Measurements of power density have been made at 17 sites where people were concerned about their exposure to radio waves from mobile phone base stations and where technical data, including the frequencies and radiated powers, have been obtained from the operators. Based on the technical data, the radiated power from antennas used with macrocellular base stations in the UK appears to range from a few watts to a few tens of watts, with typical maximum powers around 80 W. Calculations based on this power indicate that compliance distances would be expected to be no more than 3.1 m for the NRPB guidelines and no more than 8.4 m for the ICNIRP public guidelines. Microcellular base stations appear to use powers no more than a few watts and would not be expected to require compliance distances in excess of a few tens of centimetres. Power density from the base stations of interest was measured at 118 locations at the 17 sites and these data were compared with calculations assuming an inverse square law dependence of power density upon distance from the antennas. It was found that the calculations overestimated the measured power density by up to four orders of magnitude at locations that were either not exposed to the main beam from antennas, or shielded by building fabric. For all locations and for distances up to 250 m from the base stations, power density at the measurement positions did not show any trend to decrease with increasing distance. The signals from other sources were frequently found to be of similar strength to the signals from the base stations of interest. Spectral measurements were obtained over the 30 MHz to 2.9 GHz range at 73 of the locations so that total exposure to radio signals could be assessed. The geometric mean total exposure arising from all radio signals at the locations considered was 2 millionths of the NRPB investigation level, or 18 millionths of the lower ICNIRP public reference level; however, the data varied over several decades. The

  15. 47 CFR 73.1120 - Station location.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Station location. 73.1120 Section 73.1120... Rules Applicable to All Broadcast Stations § 73.1120 Station location. Each AM, FM, TV and Class A TV... be the geographical station location. [65 FR 30003, May 10, 2000] ...

  16. Investigation of the exposure level of electromagnetic fields produced by mobile telephone base stations

    International Nuclear Information System (INIS)

    Abukassem, I.; Kharita, M. H.

    2010-12-01

    The aim of this work is to investigate the real values of microwave level distribution and propagation in the locality around samples of mobile phone base station, and to compare the results with the exposure restriction limits recommenced by the International Commission on Non Ionizing Radiation Protection (ICNIRP). Measurements were performed using special meters for microwaves; the first (Narda SRM-3000) is used for electromagnetic waves frequency spectrum scanning and the second (NARDA) emr 300) determine the level of electric and magnetic fields and the power density of these waves nearby any sort of transmitters. Samples of different kinds of mobile phone base station were chosen to cover important zones of Damascus, and the region around each base station was also scanned in the emission direction and according to accessibility into the studies positions. Results showed that the signal level in all measured points is lower than the ICNIRP restriction level, but for few points the detected microwave level has relatively important values. The signal level inside building situated partially in the emission direction of the base station transmitters decreases stepwise and walls reduce considerably the signal intensity. To realize these kind of field studies in the best way and obtain the maximum profits for all people, the properties and operating system of transmitters used in mobile phone base station must be known, and therefore, it is very important to achieve a transparent collaboration between research laboratory and mobile phone company. (author)

  17. Observations on the Reliability of Rubidium Frequency Standards on Block 2/2A GPS Satellites

    Science.gov (United States)

    Dieter, Gary L.

    1996-01-01

    Currently, the block 2/2A Global Positioning System (GPS) satellites are equipped with two rubidium frequency standards. These frequency standards were originally intended to serve as the back-ups to two cesium frequency standards. As the constellation ages, the master Control Station is forced to initialize and increasing number or rubidium frequency standards. Unfortunately the operational use of these frequency standards has not lived up to initial expectations. Although the performance of these rubidium frequency standards has met and even exceeded GPS requirements, their reliability has not. The number of unscheduled outage times and the short operational lifetimes of the rubidium frequency standards compare poorly to the track record of the cesium frequency standards. Only a small number of rubidium frequency standards have actually been made operational. Of these, a large percentage have exhibited poor reliability. If this trend continues, it is unlikely that the rubidium frequency standards will help contribute to the navigation payload meeting program specification.

  18. Research on the optimization of air quality monitoring station layout based on spatial grid statistical analysis method.

    Science.gov (United States)

    Li, Tianxin; Zhou, Xing Chen; Ikhumhen, Harrison Odion; Difei, An

    2018-05-01

    In recent years, with the significant increase in urban development, it has become necessary to optimize the current air monitoring stations to reflect the quality of air in the environment. Highlighting the spatial representation of some air monitoring stations using Beijing's regional air monitoring station data from 2012 to 2014, the monthly mean particulate matter concentration (PM10) in the region was calculated and through the IDW interpolation method and spatial grid statistical method using GIS, the spatial distribution of PM10 concentration in the whole region was deduced. The spatial distribution variation of districts in Beijing using the gridding model was performed, and through the 3-year spatial analysis, PM10 concentration data including the variation and spatial overlay (1.5 km × 1.5 km cell resolution grid), the spatial distribution result obtained showed that the total PM10 concentration frequency variation exceeded the standard. It is very important to optimize the layout of the existing air monitoring stations by combining the concentration distribution of air pollutants with the spatial region using GIS.

  19. Water Level Station History

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Images contain station history information for 175 stations in the National Water Level Observation Network (NWLON). The NWLON is a network of long-term,...

  20. Mechanism of High Frequency Shallow Earthquake Source in Mount Soputan, North Sulawesi

    Directory of Open Access Journals (Sweden)

    Yasa Suparman

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v6i3.122Moment tensor analysis had been conducted to understand the source mechanism of earthquakes in Soputan Volcano during October - November 2010 period. The record shows shallow earthquakes with frequency about 5 - 9 Hz. Polarity distribution of P-wave first onset indicates that the recorded earthquakes are predominated by earthquakes where almost at all stations have the same direction of P-wave first motions, and earthquakes with upward first motions.In this article, the source mechanism is described as the second derivative of moment tensor, approached with first motion amplitude inversion of P-wave at some seismic stations. The result of moment tensor decomposition are predominated by earthquakes with big percentage in ISO and CLVD component. Focal mechanism shows that the recorded earthquakes have the same strike in northeast-southwest direction with dip about 400 - 600. The sources of the high frequency shallow earthquakes are in the form of tensile-shear cracks or a combination between crack and tensile faulting.

  1. MELRPI - development and use

    International Nuclear Information System (INIS)

    Sozer, A.

    1985-01-01

    The MELRPI computer code has been developed by Rensselaer Polytechnic Institute under the sponsorship of Oak Ridge National Laboratory (ORNL) and, more recently, the Empire State Electrical Energy Research Corporation (ESEERCO). The code was developed especially for severe accident analyses concerning BWRs and is not applicable to PWRs. MELRPI.MOD2, one of the ORNL-severe accident analysis codes, has been applied for the first time to station blackout transient analysis for the Browns Ferry nuclear power plant in order to estimate the progression of core degradation

  2. Calculation of spent fuel pool severe accident with MELCOR

    International Nuclear Information System (INIS)

    Deng Jian; Xiang Qing'an; Zhou Kefeng

    2014-01-01

    A calculation model was established for spent fuel pool (SFP) using MELCOR code to study the severe accident phenomena caused by the long term station black-out (SBO), including spent fuel heatup, zirconium cladding oxidation, and the injection into SFP to mitigate the severe accident. The results show that the severe accident progression is slow and relates directly with the initial water level in SFP. It is illustrated that the injection into SFP is one of the best mitigated measures for the SFP severe accident. (authors)

  3. The modeling and analysis of in-vessel corium/structure interaction in boiling water reactors

    International Nuclear Information System (INIS)

    Podowski, M.Z.; Kurul, N.; Kim, S.-W.; Baltyn, W.; Frid, W.

    1997-01-01

    A complete stand-alone state-of-the-art model has been developed of the interaction between corium debris in the lower plenum and the RPV walls and internal structures, including the vessel failure mechanisms. This new model has been formulated as a set of consistent computer modules which could be linked with other existing models and/or computer codes. The combined lower head and lower plenum modules were parametrically tested and applied to predict the consequences of a hypothetical station blackout in a Swedish BWR. (author)

  4. Simulation of accident and restrained transients in PWR nuclear power plant with RELAP 5/MOD 1 computer code

    International Nuclear Information System (INIS)

    Silva Filho, E.

    1986-01-01

    The computer code RELAP5/MOD1 has been utilized to investigate the thermal-hydraulic behaviour of a standard 1300 Mwe pressurized water reactor plant of the KWU design during a station blackout and during a loss-of-coolant accident involving 2% break in the cross-sectional area the cold leg in one of the four loops and located between the pump and the reactor pressure vessel. During the simulations the reactor scram system and the emergency coolant system were considered inactive. (Author) [pt

  5. Tidal Analysis Using Time–Frequency Signal Processing and Information Clustering

    Directory of Open Access Journals (Sweden)

    Antonio M. Lopes

    2017-07-01

    Full Text Available Geophysical time series have a complex nature that poses challenges to reaching assertive conclusions, and require advanced mathematical and computational tools to unravel embedded information. In this paper, time–frequency methods and hierarchical clustering (HC techniques are combined for processing and visualizing tidal information. In a first phase, the raw data are pre-processed for estimating missing values and obtaining dimensionless reliable time series. In a second phase, the Jensen–Shannon divergence is adopted for measuring dissimilarities between data collected at several stations. The signals are compared in the frequency and time–frequency domains, and the HC is applied to visualize hidden relationships. In a third phase, the long-range behavior of tides is studied by means of power law functions. Numerical examples demonstrate the effectiveness of the approach when dealing with a large volume of real-world data.

  6. A Method for Estimating BeiDou Inter-frequency Satellite Clock Bias

    Directory of Open Access Journals (Sweden)

    LI Haojun

    2016-02-01

    Full Text Available A new method for estimating the BeiDou inter-frequency satellite clock bias is proposed, considering the shortage of the current methods. The constant and variable parts of the inter-frequency satellite clock bias are considered in the new method. The data from 10 observation stations are processed to validate the new method. The characterizations of the BeiDou inter-frequency satellite clock bias are also analyzed using the computed results. The results of the BeiDou inter-frequency satellite clock bias indicate that it is stable in the short term. The estimated BeiDou inter-frequency satellite clock bias results are molded. The model results show that the 10 parameters of model for each satellite can express the BeiDou inter-frequency satellite clock bias well and the accuracy reaches cm level. When the model parameters of the first day are used to compute the BeiDou inter-frequency satellite clock bias of the second day, the accuracy also reaches cm level. Based on the stability and modeling, a strategy for the BeiDou satellite clock service is presented to provide the reference of our BeiDou.

  7. Unidirectional Magneto-Electric Dipole Antenna for Base Station: A Review

    Science.gov (United States)

    Idayachandran, Govindanarayanan; Nakkeeran, Rangaswamy

    2018-04-01

    Unidirectional base station antenna design using Magneto-Electric Dipole (MED) has created enormous interest among the researchers due to its excellent radiation characteristics like low back radiation, symmetrical radiation at E-plane and H-plane compared to conventional patch antenna. Generally, dual polarized antennas are used to increase channel capacity and reliability of the communication systems. In order to serve the evolving mobile communication standards like long term evolution LTE and beyond, unidirectional dual polarized MED antenna are required to have broad impedance bandwidth, broad half power beamwidth, high port isolation, low cross polarization level, high front to back ratio and high gain. In this paper, the critical electrical requirements of the base station antenna and frequently used frequency bands for modern mobile communication have been presented. It is followed by brief review on broadband patch antenna and discussion on complementary antenna concepts. Finally, the performance of linearly polarized and dual polarized magneto-electric dipole antennas along with their feeding techniques are discussed and summarized. Also, design and modeling of developed MED antenna is presented.

  8. Local society and nuclear power stations

    International Nuclear Information System (INIS)

    1984-02-01

    This report was made by the expert committee on region investigation, Japan Atomic Industrial Forum Inc., in fiscal years 1981 and 1982 in order to grasp the social economic influence exerted on regions by the location of nuclear power stations and the actual state of the change due to it, and to search for the way the promotion of local community should be. The influence and the effect were measured in the regions around the Fukushima No. 1 Nuclear Power Station of Tokyo Electric Power Co., Inc., the Mihama Power Station of Kansai Electric Power Co., Inc., and the Genkai Nuclear Power Station of Kyushu Electric Power Co., Inc. The fundamental recognition in this discussion, the policy of locating nuclear power stations and the management of regions, the viewpoint and way of thinking in the investigation of the regions where nuclear power stations are located, the actual state of social economic impact due to the location of nuclear power stations, the connected mechanism accompanying the location of nuclear power stations, and the location of nuclear power stations and the acceleration of planning for regional promotion are reported. In order to economically generate electric power, the rationalization in the location of nuclear power stations is necessary, and the concrete concept of building up local community must be decided. (Kako, I.)

  9. 47 CFR 25.221 - Blanket Licensing provisions for Earth Stations on Vessels (ESVs) receiving in the 3700-4200 MHz...

    Science.gov (United States)

    2010-10-01

    ... the 5925-6425 MHz (Earth-to-space) frequency band, operating with Geostationary Satellite Orbit (GSO) Satellites in the Fixed-Satellite Service. 25.221 Section 25.221 Telecommunication FEDERAL COMMUNICATIONS... 47 Telecommunication 2 2010-10-01 2010-10-01 false Blanket Licensing provisions for Earth Stations...

  10. 47 CFR 25.137 - Application requirements for earth stations operating with non-U.S. licensed space stations.

    Science.gov (United States)

    2010-10-01

    ... space stations. (a) Earth station applicants or entities filing a “letter of intent” or “Petition for... Union. (d) Earth station applicants requesting authority to operate with a non-U.S.-licensed space... 47 Telecommunication 2 2010-10-01 2010-10-01 false Application requirements for earth stations...

  11. Quantifying the Benefits of Shallow Posthole Installation for the Future French Permanent Broadband Stations

    Science.gov (United States)

    Vergne, J.; Charade, O.; Bonaime, S.; Louis-Xavier, T.; Arnold, B.

    2015-12-01

    In the framework of the RESIF (réseau sismologique et géodésique français) infrastructure, more than one hundred new permanent broadband stations have to be deployed in metropolitan France within the forthcoming years. This requires a standardized installation method able to provide good noise level performance at a reasonable cost, especially for the 60 percent of stations that we expect to be settled in open environments. During the last two years we tested various types of sensor's hosting infrastructures with a strong focus on recently released posthole sensors that can be deployed at the bottom of shallow boreholes. Tests were performed at 3 different sites (two GEOSCOPE stations and a dedicated open-field prototype site) with geological conditions spanning from hard rocks to very soft soils. On each site, posthole sensors were deployed at different depths, from the surface to a maximum of 20m deep, and in different types of casing. Moreover, a reference sensor, either installed in a tunnel, a cellar or a seismic vault, has been operated continuously. We present a comprehensive comparison of the seismic noise level measured in the different hosting infrastructures and for several frequency bands corresponding to various sources of noise. At high and low frequencies, seismic noise level in some boreholes equals or outperforms the one obtained for the reference sensors. Between 0.005 and 0.05Hz, we observe a strong decrease of seismic noise level on the horizontal components in the deepest boreholes compared to near surface installations. This improvement can reach up to 30dB and is mostly due to a reduction in tilt noise induced by wind or local pressure variations. However, the absolute noise level that can be achieved clearly depends on the local geology. All these tests, together with estimated installation costs, point toward the deployment of sensors in shallow boreholes at the future French broadband stations located in open environments.

  12. Sounding rocket experiments during the IMS period at Syowa Station, Antarctica

    International Nuclear Information System (INIS)

    Hirasawa, T.; Nagata, T.

    1979-01-01

    During IMS Period, 19 sounding rockets were launched into auroras at various stages of polar substorms from Syowa Station (Geomag. lat. = -69.6 0 , Geomag. log. = 77.1 0 ), Antarctica. Through the successful rocket flights, the significant physical quantities in auroras were obtained: 19 profiles of electron density and temperature, 11 energy spectra of precipitating electrons, 15 frequency spectra of VLF and HF plasma waves and 4 vertical profiles of electric and magnetic fields. These rocket data have been analyzed and compared with the coordinated ground-based observation data for studies of polar substorms. (author)

  13. Probabilistic fire risk assessment for Koeberg Nuclear Power Station Unit 1

    International Nuclear Information System (INIS)

    Grobbelaar, J.F.; Foster, N.A.S.; Luesse, L.J.

    1995-01-01

    A probabilistic fire risk assessment was done for Koeberg Nuclear Power Station Unit 1. Areas where fires are likely to start were identified. Equipment important to safety, as well as their power and/or control cable routes were identified in each fire confinement sector. Fire confinement sectors where internal initiating events could be caused by fire were identified. Detection failure and suppression failure fault trees and event trees were constructed. The core damage frequency associated with each fire confinement sector was calculated, and important fire confinement sectors were identified. (author)

  14. Flood-frequency characteristics of Wisconsin streams

    Science.gov (United States)

    Walker, John F.; Peppler, Marie C.; Danz, Mari E.; Hubbard, Laura E.

    2017-05-22

    Flood-frequency characteristics for 360 gaged sites on unregulated rural streams in Wisconsin are presented for percent annual exceedance probabilities ranging from 0.2 to 50 using a statewide skewness map developed for this report. Equations of the relations between flood-frequency and drainage-basin characteristics were developed by multiple-regression analyses. Flood-frequency characteristics for ungaged sites on unregulated, rural streams can be estimated by use of the equations presented in this report. The State was divided into eight areas of similar physiographic characteristics. The most significant basin characteristics are drainage area, soil saturated hydraulic conductivity, main-channel slope, and several land-use variables. The standard error of prediction for the equation for the 1-percent annual exceedance probability flood ranges from 56 to 70 percent for Wisconsin Streams; these values are larger than results presented in previous reports. The increase in the standard error of prediction is likely due to increased variability of the annual-peak discharges, resulting in increased variability in the magnitude of flood peaks at higher frequencies. For each of the unregulated rural streamflow-gaging stations, a weighted estimate based on the at-site log Pearson type III analysis and the multiple regression results was determined. The weighted estimate generally has a lower uncertainty than either the Log Pearson type III or multiple regression estimates. For regulated streams, a graphical method for estimating flood-frequency characteristics was developed from the relations of discharge and drainage area for selected annual exceedance probabilities. Graphs for the major regulated streams in Wisconsin are presented in the report.

  15. Power consumption analysis of pump station control systems based on fuzzy controllers with discrete terms in iThink software

    Science.gov (United States)

    Muravyova, E. A.; Bondarev, A. V.; Sharipov, M. I.; Galiaskarova, G. R.; Kubryak, A. I.

    2018-03-01

    In this article, power consumption of pumping station control systems is discussed. To study the issue, two simulation models of oil level control in the iThink software have been developed, using a frequency converter only and using a frequency converter and a fuzzy controller. A simulation of the oil-level control was carried out in a graphic form, and plots of pumps power consumption were obtained. Based on the initial and obtained data, the efficiency of the considered control systems has been compared, and also the power consumption of the systems was shown graphically using a frequency converter only and using a frequency converter and a fuzzy controller. The models analysis has shown that it is more economical and safe to use a control circuit with a frequency converter and a fuzzy controller.

  16. Establishment of Karadeniz Technical University Permanent GNSS Station as Reactivated of TRAB IGS Station

    Directory of Open Access Journals (Sweden)

    Kazancı Selma Zengin

    2017-12-01

    Full Text Available In recent years, Global Navigation Satellite Systems (GNSS have gained great importance in terms of the benefi ts it provides such as precise geodetic point positioning, determining crustal deformations, navigation, vehicle monitoring systems and meteorological applications etc. As in Turkey, for this purpose, each country has set up its own GNSS station networks like Turkish National Permanent RTK Network analyzed precise station coordinates and velocities together with the International GNSS Service, Turkish National Fundamental GPS Network and Turkish National Permanent GNSS Network (TNPGN stations not only are utilized as precise positioning but also GNSS meteorology studies so total number of stations are increased. This work is related to the reactivated of the TRAB IGS station which was established in Karadeniz Technical University, Department of Geomatics Engineering. Within the COST ES1206 Action (GNSS4SWEC KTU analysis center was established and Trop-NET system developed by Geodetic Observatory Pecny (GOP, RIGTC in order to troposphere monitoring. The project titled “Using Regional GNSS Networks to Strengthen Severe Weather Prediction” was accepted to the scientifi c and technological research council of Turkey (TUBITAK. With this project, we will design 2 new constructed GNSS reference station network. Using observation data of network, we will compare water vapor distribution derived by GNSS Meteorology and GNSS Tomography. At this time, KTU AC was accepted as E-GVAP Analysis Centre in December 2016. KTU reference station is aimed to be a member of the EUREF network with these studies.

  17. Establishment of Karadeniz Technical University Permanent GNSS Station as Reactivated of TRAB IGS Station

    Science.gov (United States)

    Kazancı, Selma Zengin; Kayıkçı, Emine Tanır

    2017-12-01

    In recent years, Global Navigation Satellite Systems (GNSS) have gained great importance in terms of the benefi ts it provides such as precise geodetic point positioning, determining crustal deformations, navigation, vehicle monitoring systems and meteorological applications etc. As in Turkey, for this purpose, each country has set up its own GNSS station networks like Turkish National Permanent RTK Network analyzed precise station coordinates and velocities together with the International GNSS Service, Turkish National Fundamental GPS Network and Turkish National Permanent GNSS Network (TNPGN) stations not only are utilized as precise positioning but also GNSS meteorology studies so total number of stations are increased. This work is related to the reactivated of the TRAB IGS station which was established in Karadeniz Technical University, Department of Geomatics Engineering. Within the COST ES1206 Action (GNSS4SWEC) KTU analysis center was established and Trop-NET system developed by Geodetic Observatory Pecny (GOP, RIGTC) in order to troposphere monitoring. The project titled "Using Regional GNSS Networks to Strengthen Severe Weather Prediction" was accepted to the scientifi c and technological research council of Turkey (TUBITAK). With this project, we will design 2 new constructed GNSS reference station network. Using observation data of network, we will compare water vapor distribution derived by GNSS Meteorology and GNSS Tomography. At this time, KTU AC was accepted as E-GVAP Analysis Centre in December 2016. KTU reference station is aimed to be a member of the EUREF network with these studies.

  18. Advances in power station construction

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    This book is about power stations - specifically about the construction of modern power stations by the Central Electricity Generating Board in England and Wales over the past decade. It describes the work of the CEGB's Generation Development and Construction Division, perhaps better known throughout the world as simply 'Barnwood' where it has its Headquarters in Gloucester, UK. Barnwood was formed in the early 1970s to concentrate the CEGB's then dispersed engineering construction resources to cope with the smaller number but greatly increased size and complexity of modern power station projects. Perhaps uniquely over the ten years since its formation Barnwood has managed the construction of all types of station; coal-fired, oil-fired, nuclear, pumped storage and hydro. This book tells the story of these various projects and gives detailed descriptions of the respective stations. However, it is not intended as a comprehensive description of power station technology. Rather it is intended to convey the scale of such projects and the many decisions and compromises which have to be made in the course of managing their construction

  19. The Princess Elisabeth Station

    Science.gov (United States)

    Berte, Johan

    2012-01-01

    Aware of the increasing impact of human activities on the Earth system, Belgian Science Policy Office (Belspo) launched in 1997 a research programme in support of a sustainable development policy. This umbrella programme included the Belgian Scientific Programme on Antarctic Research. The International Polar Foundation, an organization led by the civil engineer and explorer Alain Hubert, was commissioned by the Belgian Federal government in 2004 to design, construct and operate a new Belgian Antarctic Research Station as an element under this umbrella programme. The station was to be designed as a central location for investigating the characteristic sequence of Antarctic geographical regions (polynia, coast, ice shelf, ice sheet, marginal mountain area and dry valleys, inland plateau) within a radius of 200 kilometers (approx.124 miles) of a selected site. The station was also to be designed as "state of the art" with respect to sustainable development, energy consumption, and waste disposal, with a minimum lifetime of 25 years. The goal of the project was to build a station and enable science. So first we needed some basic requirements, which I have listed here; plus we had to finance the station ourselves. Our most important requirement was that we decided to make it a zero emissions station. This was both a philosophical choice as we thought it more consistent with Antarctic Treaty obligations and it was also a logistical advantage. If you are using renewable energy sources, you do not have to bring in all the fuel.

  20. Experimental investigations of overvoltages in 6kV station service cable networks of thermal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Vukelja, P.I.; Naumov, R.M.; Drobnjak, G.V.; Mrvic, J.D. [Nikola Tesla Inst., Belgrade (Yugoslavia)

    1996-12-31

    The paper presents the results of experimental investigations of overvoltages on 6kV isolated neutral station service cable networks of thermal power plants. The overvoltages were recorded with capacitive voltage measurement systems made at the Nikola Tesla Institute. Wideband capacitive voltage measurement systems recorded a flat response from below power frequencies to 10MHz. Investigations of overvoltages were performed for appearance and interruption of metal earth faults, intermittent earth faults, switching operation of HV motors switchgear, switching operation of transformers switchgear, and transfer of the network supply from one transformer to another. On the basis of these investigations, certain measures are proposed for limiting overvoltages and for the reliability of station service of thermal power plants.