WorldWideScience

Sample records for static tests

  1. 40 CFR 53.64 - Test procedure: Static fractionator test.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedure: Static fractionator test. 53.64 Section 53.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Performance Characteristics of Class II Equivalent Methods for PM2.5 § 53.64 Test procedure: Static...

  2. Literature review Quasi-static and Dynamic pile load tests : Primarily report on non-static pile load tests

    NARCIS (Netherlands)

    Huy, N.Q.

    2010-01-01

    Pile testing, which plays an importance role in the field of deep foundation design, is performed by static and non-static methods to provide information about the following issues: (Poulos, 1998) - The ultimate capacity of a single pile. - The load-displacement behavior of a pile. - The performance

  3. A Static Burst Test for Composite Flywheel Rotors

    Science.gov (United States)

    Hartl, Stefan; Schulz, Alexander; Sima, Harald; Koch, Thomas; Kaltenbacher, Manfred

    2016-06-01

    High efficient and safe flywheels are an interesting technology for decentralized energy storage. To ensure all safety aspects, a static test method for a controlled initiation of a burst event for composite flywheel rotors is presented with nearly the same stress distribution as in the dynamic case, rotating with maximum speed. In addition to failure prediction using different maximum stress criteria and a safety factor, a set of tensile and compressive tests is carried out to identify the parameters of the used carbon fiber reinforced plastics (CFRP) material. The static finite element (FE) simulation results of the flywheel static burst test (FSBT) compare well to the quasistatic FE-simulation results of the flywheel rotor using inertia loads. Furthermore, it is demonstrated that the presented method is a very good controllable and observable possibility to test a high speed flywheel energy storage system (FESS) rotor in a static way. Thereby, a much more expensive and dangerous dynamic spin up test with possible uncertainties can be substituted.

  4. Multiaxial pedicle screw designs: static and dynamic mechanical testing.

    Science.gov (United States)

    Stanford, Ralph Edward; Loefler, Andreas Herman; Stanford, Philip Mark; Walsh, William R

    2004-02-15

    Randomized investigation of multiaxial pedicle screw mechanical properties. Measure static yield and ultimate strengths, yield stiffness, and fatigue resistance according to an established model. Compare these measured properties with expected loads in vivo. Multiaxial pedicle screws provide surgical versatility, but the complexity of their design may reduce their strength and fatigue resistance. There is no published data on the mechanical properties of such screws. Screws were assembled according to a vertebrectomy model for destructive mechanical testing. Groups of five assemblies were tested in static tension and compression and subject to three cyclical loads. Modes of failure, yield, and ultimate strength, yield stiffness, and cycles to failure were determined for six designs of screw. Static compression yield loads ranged from 217.1 to 388.0 N and yield stiffness from 23.7 to 38.0 N/mm. Cycles to failure ranged from 42 x 10(3) to 4,719 x 10(3) at 75% of static ultimate load. There were significant differences between designs in all modes of testing. Failure occurred at the multiaxial link in static and cyclical compression. Bending yield strengths just exceeded loads expected in vivo. Multiaxial designs had lower static bending yield strength than fixed screw designs. Five out of six multiaxial screw designs achieved one million cycles at 200 N in compression bending. "Ball-in-cup" multiaxial locking mechanisms were vulnerable to fatigue failure. Smooth surfaces and thicker material appeared to be protective against fatigue failure.

  5. Pilot Study: Foam Wedge Chin Support Static Tolerance Testing

    Science.gov (United States)

    2017-10-24

    AFRL-SA-WP-SR-2017-0026 Pilot Study: Foam Wedge Chin Support Static Tolerance Testing Austin M. Fischer, BS1; William W...COVERED (From – To) April – October 2017 4. TITLE AND SUBTITLE Pilot Study: Foam Wedge Chin Support Static Tolerance Testing 5a. CONTRACT NUMBER...PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) USAF School of Aerospace

  6. Self-Testing Static Random-Access Memory

    Science.gov (United States)

    Chau, Savio; Rennels, David

    1991-01-01

    Proposed static random-access memory for computer features improved error-detecting and -correcting capabilities. New self-testing scheme provides for detection and correction of errors at any time during normal operation - even while data being written into memory. Faults in equipment causing errors in output data detected by repeatedly testing every memory cell to determine whether it can still store both "one" and "zero", without destroying data stored in memory.

  7. [Static posturography versus clinical tests in elderly people with vestibular pathology].

    Science.gov (United States)

    Ortuño-Cortés, Miguel A; Martín-Sanz, Eduardo; Barona-de Guzmán, Rafael

    2008-01-01

    Balance can be quantified by clinical tests and through instrumental studies. The objective of this paper is to determine the correlation between static posturography and 4 clinical tests of balance in elderly people with vestibular disorders and to identify its capability to discriminate the groups studied. 60 patients with vestibular disorders and 60 healthy subjects performed 4 clinical tests (one leg standing with opened eyes, Timed Up and Go, Tinetti and Berg tests) and a static posturography analysis (NedSVE/IBV system) under 4 conditions: Romberg Test, Eyes Open (REO), Romberg Test, Eyes Closed (REC), Romberg Test on Foam with Eyes Open (RFEO), and Romberg Test on Foam with Eyes Closed (RFEC). RFEO correlated best with the clinical tests and RFEC was the worst. RFEO distinguished between healthy individuals and decompensated patients. RFEO gave the best information about postural balance in the elderly. RFEC was not useful. Static posturography can be useful to distinguish vestibular compensation status.

  8. Structural testing for static failure, flutter and other scary things

    Science.gov (United States)

    Ricketts, R. H.

    1983-01-01

    Ground test and flight test methods are described that may be used to highlight potential structural problems that occur on aircraft. Primary interest is focused on light-weight general aviation airplanes. The structural problems described include static strength failure, aileron reversal, static divergence, and flutter. An example of each of the problems is discussed to illustrate how the data acquired during the tests may be used to predict the occurrence of the structural problem. While some rules of thumb for the prediction of structural problems are given the report is not intended to be used explicitly as a structural analysis handbook.

  9. Static and Dynamic Handgrip Strength Endurance: Test-Retest Reproducibility.

    Science.gov (United States)

    Gerodimos, Vassilis; Karatrantou, Konstantina; Psychou, Dimitra; Vasilopoulou, Theodora; Zafeiridis, Andreas

    2017-03-01

    This study investigated the reliability of static and dynamic handgrip strength endurance using different protocols and indicators for the assessment of strength endurance. Forty young, healthy men and women (age, 18-22 years) performed 2 handgrip strength endurance protocols: a static protocol (sustained submaximal contraction at 50% of maximal voluntary contraction) and a dynamic one (8, 10, and 12 maximal repetitions). The participants executed each protocol twice to assess the test-retest reproducibility. Total work and total time were used as indicators of strength endurance in the static protocol; the strength recorded at each maximal repetition, the percentage change, and fatigue index were used as indicators of strength endurance in the dynamic protocol. The static protocol showed high reliability irrespective of sex and hand for total time and work. The 12-repetition dynamic protocol exhibited moderate-high reliability for repeated maximal repetitions and percentage change; the 8- and 10-repetition protocols demonstrated lower reliability irrespective of sex and hand. The fatigue index was not a reliable indicator for the assessment of dynamic handgrip endurance. Static handgrip endurance can be measured reliably using the total time and total work as indicators of strength endurance. For the evaluation of dynamic handgrip endurance, the 12-repetition protocol is recommended, using the repeated maximal repetitions and percentage change as indicators of strength endurance. Practitioners should consider the static (50% maximal voluntary contraction) and dynamic (12 repeated maximal repetitions) protocols as reliable for the assessment of handgrip strength endurance. The evaluation of static endurance in conjunction with dynamic endurance would provide more complete information about hand function. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. 33 CFR 183.580 - Static pressure test for fuel tanks.

    Science.gov (United States)

    2010-07-01

    ... pressure test for fuel tanks. A fuel tank is tested by performing the following procedures in the following... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Static pressure test for fuel tanks. 183.580 Section 183.580 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND...

  11. Towards building a neural network model for predicting pile static load test curves

    Directory of Open Access Journals (Sweden)

    Alzo’ubi A. K.

    2018-01-01

    Full Text Available In the United Arab Emirates, Continuous Flight Auger piles are the most widely used type of deep foundation. To test the pile behaviour, the Static Load Test is routinely conducted in the field by increasing the dead load while monitoring the displacement. Although the test is reliable, it is expensive to conduct. This test is usually conducted in the UAE to verify the pile capacity and displacement as the load increase and decreases in two cycles. In this paper we will utilize the Artificial Neural Network approach to build a model that can predict a complete Static Load Pile test. We will show that by integrating the pile configuration, soil properties, and ground water table in one artificial neural network model, the Static Load Test can be predicted with confidence. We believe that based on this approach, the model is able to predict the entire pile load test from start to end. The suggested approach is an excellent tool to reduce the cost associated with such expensive tests or to predict pile’s performance ahead of the actual test.

  12. FEM simulation of static loading test of the Omega beam

    Science.gov (United States)

    Bílý, Petr; Kohoutková, Alena; Jedlinský, Petr

    2017-09-01

    The paper deals with a FEM simulation of static loading test of the Omega beam. Omega beam is a precast prestressed high-performance concrete element with the shape of Greek letter omega. Omega beam was designed as a self-supporting permanent formwork member for construction of girder bridges. FEM program ATENA Science was exploited for simulation of load-bearing test of the beam. The numerical model was calibrated using the data from both static loading test and tests of material properties. Comparison of load-displacement diagrams obtained from the experiment and the model was conducted. Development of cracks and crack patterns were compared. Very good agreement of experimental data and the FEM model was reached. The calibrated model can be used for design of optimized Omega beams in the future without the need of expensive loading tests. The calibrated material model can be also exploited in other types of FEM analyses of bridges constructed with the use of Omega beams, such as limit state analysis, optimization of shear connectors, prediction of long-term deflections or prediction of crack development.

  13. Mesoscopic analyses of porous concrete under static compression and drop weight impact tests

    DEFF Research Database (Denmark)

    Agar Ozbek, A.S.; Pedersen, R.R.; Weerheijm, J.

    2008-01-01

    was considered as a four-phase material incorporating aggregates, bulk cement paste, interfacial transition zones and meso-size air pores. The stress-displacement relations obtained from static compression tests, the stress values, and the corresponding damage levels provided by the drop weight impact tests were......The failure process in highly porous concrete was analyzed experimentally and numerically. A triaxial visco-plastic damage model and a mesoscale representation of the material composition were considered to reproduce static compression and drop weight impact tests. In the mesoscopic model, concrete...

  14. Elevated-Temperature Tests Under Static and Aerodynamic Conditions on Honeycomb-Core Sandwich Panels

    Science.gov (United States)

    Groen, Joseph M.; Johnson, Aldie E., Jr.

    1959-01-01

    Stainless-steel honeycomb-core sandwich panels which differed primarily in skin thicknesses were tested at elevated temperatures under static and aerodynamic conditions. The results of these tests were evaluated to determine the insulating effectiveness and structural integrity of the panels. The static radiant-heating tests were performed in front of a quartz-tube radiant heater at panel skin temperatures up to 1,5000 F. The aerodynamic tests were made in a Mach 1.4 heated blowdown wind tunnel. The tunnel temperature was augmented by additional heat supplied by a radiant heater which raised the panel surface temperature above 8000 F during air flow. Static radiant-heating tests of 2 minutes duration showed that all the panels protected the load-carrying structure about equally well. Thin-skin panels showed an advantage for this short-time test over thick-skin panels from a standpoint of weight against insulation. Permanent inelastic strains in the form of local buckles over each cell of the honeycomb core caused an increase in surface roughness. During the aero- dynamic tests all of the panels survived with little or no damage, and panel flutter did not occur.

  15. Measuring Cognitive Load in Test Items: Static Graphics versus Animated Graphics

    Science.gov (United States)

    Dindar, M.; Kabakçi Yurdakul, I.; Inan Dönmez, F.

    2015-01-01

    The majority of multimedia learning studies focus on the use of graphics in learning process but very few of them examine the role of graphics in testing students' knowledge. This study investigates the use of static graphics versus animated graphics in a computer-based English achievement test from a cognitive load theory perspective. Three…

  16. Investigation of a precise static leach test for the testing of simulated nuclear waste materials

    International Nuclear Information System (INIS)

    Kingston, H.M.; Cronin, D.J.; Epstein, M.S.

    1984-01-01

    The precision of the nuclear waste static leach test was evaluated using controlled experimental conditions and homogeneous glass materials. The majority of the leachate components were subjected to simultaneous multielement DCP analysis. The overall precision of the static leach test is determined by the summation of random effects caused by: variance in the experimental conditions of the leaching procedure; inhomogeneity of the material to be leached; and variance of the analytical techniques used to determine elemental concentrations in the leachate. In this study, strict control of key experimental parameters was employed to reduce the first source of variance. In addition, special attention to the preparation of glass samples to be tested assured a high degree of homogeneity. Described here are the details of the reduction of these two sources of variance to a point where the overall test precision is limited by that of the analysis step. Of the elements determined - B, Ba, Ca, Cs, Mo, Na, Si, Sr, and Zn - only Ca and Zn exhibited replicate imprecision significantly greater than that observed in the analysis of the leachate solutions. The imprecision in the Zn was partially attributed to the non-reproducible adsorption onto the leach vessel walls during the 28 day test period. None of the other elements exhibited this behavior

  17. Testing static quark-antiquark potentials with bottomonium

    International Nuclear Information System (INIS)

    Lichtenberg, D.B.; Predazzi, E.; Roncaglia, R.; Rosso, M.; Wills, J.G.

    1989-01-01

    We investigate the question of whether experimental data on the energy levels of bottomonium can discriminate between quark-antiquark potentials which are motivated by what we know about QCD and potentials which are purely phenomenological. We restrict ourselves to bottomonium because, of all the quarkonia observed thus far, bottomonium is the least relativistic and therefore the best testing ground for the static quarkonium potential. We consider two potentials whose functional form is motivated from perturbative QCD at short quark-antiquark separations and from nonperturbative lattice QCD at large separations. We also consider three strictly phenomenological potentials. We find that the best of the three phenomenological potentials, which has never been previously used, fits the spin-averaged data at least as well as the best of the QCD-motivated potentials. We propose further measurements on bottomium energy levels to provide additional tests. (orig.)

  18. Static Load Test on Instrumented Pile - Field Data and Numerical Simulations

    Science.gov (United States)

    Krasiński, Adam; Wiszniewski, Mateusz

    2017-09-01

    Static load tests on foundation piles are generally carried out in order to determine load - the displacement characteristic of the pile head. For standard (basic) engineering practices this type of test usually provides enough information. However, the knowledge of force distribution along the pile core and its division into the friction along the shaft and the resistance under the base can be very useful. Such information can be obtained by strain gage pile instrumentation [1]. Significant investigations have been completed on this technology, proving its utility and correctness [8], [10], [12]. The results of static tests on instrumented piles are not easy to interpret. There are many factors and processes affecting the final outcome. In order to understand better the whole testing process and soil-structure behavior some investigations and numerical analyses were done. In the paper, real data from a field load test on instrumented piles is discussed and compared with numerical simulation of such a test in similar conditions. Differences and difficulties in the results interpretation with their possible reasons are discussed. Moreover, the authors used their own analytical solution for more reliable determination of force distribution along the pile. The work was presented at the XVII French-Polish Colloquium of Soil and Rock Mechanics, Łódź, 28-30 November 2016.

  19. Static Pull Testing of a New Type of Large Deformation Cable with Constant Resistance

    Directory of Open Access Journals (Sweden)

    Zhigang Tao

    2017-01-01

    Full Text Available A new type of energy-absorbing cable, Constant-Resistance Large Deformation cable (CRLD cable with three different specifications, has been recently developed and tested. An effective cable should occupy the ability of absorbing deformation energy from these geodisaster loads and additionally must be able to yield with the sliding mass movements and plastic deformation over large distances at high displacement rates. The new cable mainly consists of constant-resistance casing tube and frictional cone unit that transfers the load from the slope. When experiencing a static or dynamic load and especially the load exceeding the constant resistance force (CR-F, a static friction force derived from the movement of frictional cone unit in casing tube of CRLD cable, the frictional cone unit will move in the casing tube along the axis and absorb deformation energy, accordingly. In order to assess the performance of three different specified cables in situ, a series of field static pull tests have been performed. The results showed that the first type of CRLD cable can yield 2000 mm displacement while acting 850 kN static pull load, which is superior to that of other two types, analyzing based on the length of the displacement and the level of static pull load.

  20. Testing static tradeoff theiry against pecking order models of capital ...

    African Journals Online (AJOL)

    We test two models with the purpose of finding the best empirical explanation for corporate financing choice of a cross section of 27 Nigerian quoted companies. The models were developed to represent the Static tradeoff Theory and the Pecking order Theory of capital structure with a view to make comparison between ...

  1. Static Aeroelastic Deformation Effects in Preliminary Wind-tunnel Tests of Silent Supersonic Technology Demonstrator

    OpenAIRE

    Makino, Yoshikazu; Ohira, Keisuke; Makimoto, Takuya; Mitomo, Toshiteru; 牧野, 好和; 大平, 啓介; 牧本, 卓也; 三友, 俊輝

    2011-01-01

    Effects of static aeroelastic deformation of a wind-tunnel test model on the aerodynamic characteristics are discussed in wind-tunnel tests in the preliminary design phase of the silent supersonic technology demonstrator (S3TD). The static aeroelastic deformation of the main wing is estimated for JAXA 2m x 2m transonic wind-tunnel and 1m x 1m supersonic wind-tunnel by a finite element method (FEM) structural analysis in which its structural model is tuned with the model deformation calibratio...

  2. Cyclic fatigue resistance of ProTaper Universal instruments when subjected to static and dynamic tests.

    Science.gov (United States)

    Lopes, Hélio P; Britto, Izabelle M O; Elias, Carlos N; Machado de Oliveira, Julio C; Neves, Mônica A S; Moreira, Edson J L; Siqueira, José F

    2010-09-01

    This study evaluated the number of cycles to fracture of ProTaper Universal S2 instruments when subjected to static and dynamic cyclic fatigue tests. ProTaper Universal S2 instruments were used until fracture in an artificial curved canal under rotational speed of 300 rpm in either a static or a dynamic test model. Afterward, the length of the fractured segments was measured and fractured surfaces and helical shafts analyzed by scanning electron microscopy (SEM). The number of cycles to fracture was significantly increased when instruments were tested in the dynamic model (Pductile mode. Plastic deformation was not observed in the helical shaft of fractured instruments. The number of cycles to fracture ProTaper Universal S2 instruments significantly increased with the use of instruments in a dynamic cyclic fatigue test compared with a static model. These findings reinforce the need for performing continuous pecking motions during rotary instrumentation of curved root canals. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  3. Static pile load tests on driven piles into Intermediate-Geo Materials.

    Science.gov (United States)

    2016-09-01

    The Wisconsin Department of Transportation (WisDOT) has concerns with both predicting pile lengths and pile capacities for H-piles driven into Intermediate-Geo Materials (IGM). The goal of the research was to perform 7 static axial load tests at 7 lo...

  4. Static and dynamic pile testing of reinforced concrete piles with structure integrated fibre optic strain sensors

    Science.gov (United States)

    Schilder, Constanze; Kohlhoff, Harald; Hofmann, Detlef; Basedau, Frank; Habel, Wolfgang R.; Baeßler, Matthias; Niederleithinger, Ernst; Georgi, Steven; Herten, Markus

    2013-05-01

    Static and dynamic pile tests are carried out to determine the load bearing capacity and the quality of reinforced concrete piles. As part of a round robin test to evaluate dynamic load tests, structure integrated fibre optic strain sensors were used to receive more detailed information about the strains along the pile length compared to conventional measurements at the pile head. This paper shows the instrumentation of the pile with extrinsic Fabry-Perot interferometers sensors and fibre Bragg gratings sensors together with the results of the conducted static load test as well as the dynamic load tests and pile integrity tests.

  5. Effects of Antiparasitic Treatment on Dynamically and Statically Tested Cognitive Skills over Time

    Science.gov (United States)

    Grigorenko, Elena L.; Sternberg, Robert J.; Jukes, Mathew; Alcock, Katie; Lambo, Jane; Ngorosho, Damaris; Nokes, Catherine; Bundy, Donald A.

    2006-01-01

    The main objective of this work was to investigate two testing procedures, repeated static tests and dynamic testing, that can more clearly demonstrate the impact of treatment for parasites in children. Rural Tanzanian children were assessed for the presence/absence and burden of helminth parasites and assigned to one of three…

  6. F-1 Engine for Saturn V Undergoing a Static Test

    Science.gov (United States)

    1964-01-01

    The flame and exhaust from the test firing of an F-1 engine blast out from the Saturn S-IB Static Test Stand in the east test area of the Marshall Space Flight Center. A Cluster of five F-1 engines, located in the S-IC (first) stage of the Saturn V vehicle, provided over 7,500,000 pounds of thrust to launch the giant rocket. The towering 363-foot Saturn V was a multistage, multiengine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  7. Assessment of Calculation Procedures for Piles in Clay Based on Static Loading Tests

    DEFF Research Database (Denmark)

    Augustesen, Anders; Andersen, Lars

    2008-01-01

    College in London. The calculation procedures are assessed based on an established database of static loading tests. To make a consistent evaluation of the design methods, corrections related to undrained shear strength and time between pile driving and testing have been employed. The study indicates...... that the interpretation of the field tests is of paramount importance, both with regard to the soil profile and the loading conditions. Based on analyses of 253 static pile loading tests distributed on 111 sites, API-RP2A provides the better description of the data. However, it should be emphasised that some input......Numerous methods are available for the prediction of the axial capacity of piles in clay. In this paper, two well-known models are considered, namely the current API-RP2A (1987 to present) and the recently developed ICP method. The latter is developed by Jardine and his co-workers at Imperial...

  8. Experimental test of static and dynamic characteristics of tilting-pad thrust bearings

    Directory of Open Access Journals (Sweden)

    Annan Guo

    2015-07-01

    Full Text Available The axial vibration in turbine machine has attracted more and more interest. Tilting-pad thrust bearings are widely used in turbine machines to support the axial load. The dynamic properties generated by oil film of the thrust pad have important effects on the axial vibration of the rotor-bearing system. It is necessary to develop the method to test the dynamic characteristics of thrust bearings. A new rig has been developed. The facility allows a complete set of bearing operating parameters to be measured. Parameters measured include oil temperatures, oil-film thickness, and pressure. The static load and dynamic load can be added on the thrust bearing in the vertical direction at the same time. The relative and absolute displacement vibrations of the test experimental bearing with the changes of dynamic force are measured, and the dynamic characteristics of the test bearing are obtained. The experimental results show clearly that the operating conditions influence largely on the pad static and dynamic characteristics.

  9. Overview of the 6 Meter HIAD Inflatable Structure and Flexible TPS Static Load Test Series

    Science.gov (United States)

    Swanson, Greg; Kazemba, Cole; Johnson, Keith; Calomino, Anthony; Hughes, Steve; Cassell, Alan; Cheatwood, Neil

    2014-01-01

    To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for this class of payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). At the beginning of 2014, a 6m HIAD inflatable structure with an integrated flexible thermal protection system (TPS) was subjected to a static load test series to verify the designs structural performance. The 6m HIAD structure was constructed in a stacked toroid configuration using nine inflatable torus segments composed of fiber reinforced thin films, which were joined together using adhesives and high strength textile woven structural straps to help distribute the loads throughout the inflatable structure. The 6m flexible TPS was constructed using multiple layers of high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for displacement of the inflatable structure as loads were applied. The bottom of the tub rim had an airtight seal with the floor. The centerbody of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to provide many data sets including: deformed shape, shoulder deflection, strap loads, cord loads, inflation pressures, and applied static load

  10. Sea-Level Static Testing of the Penn State Two-Dimensional Rocket-Based Combined Cycle (RBCC) Testbed

    Science.gov (United States)

    Cramer, J. M.; Marshall, W. M.; Pal, S.; Santoro, R. J.

    2003-01-01

    Twin thruster tests have been conducted with the Penn State RBCC test article operating at sea- level static conditions. Significant differences were observed in the performance characteristics for two different thruster centerline spacings. Changing the thruster spacing from 2.50 to 1.75 in. reduced the entrained air velocity (-17%) and the thrust (-7%) for tests at a thruster chamber pressure of 200 psia and MR = 8. In addition, significant differences were seen in the static pressure profiles, the Raman spectroscopy profiles, and the acoustic power spectrum for these two configurations.

  11. Saturn V First Stage Lowered to the Ground After Static Test

    Science.gov (United States)

    1966-01-01

    This vintage photograph shows the 138-foot long first stage of the Saturn V being lowered to the ground following a successful static test firing at Marshall Space flight Center's S-1C test stand. The firing provided NASA engineers information on the booster's systems. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  12. Definition of the linearity loss of the surface temperature in static tensile tests

    Directory of Open Access Journals (Sweden)

    A. Risitano

    2014-10-01

    Full Text Available Static tensile tests on material for mechanical constructions have pointed out the linearity loss of the surface temperature with the application of load. This phenomenon is due to the heat generation caused by the local microplasticizations which carry the material to deviate from its completely thermoelastic behavior,. The identification of the static load which determines the loss of linearity of the temperature under stress, becomes extremely important to define a first dynamic characterization of the material. The temperature variations that can be recorded during the static test are often very limited (a few tenths of degree for every 100 MPa in steels and they require the use of special sensors able to measure very low temperature variations. The experience acquired in such analysis highlighted that, dealing with highly accurate sensors or with particular materials, the identification of the first linearity loss (often by eye in the temperature curves, can be influenced by the sensibility of the investigator himself and can lead to incorrect estimates. The aim of this work is to validate the above mentioned observations on different steels, by applying the autocorrelation function to the data collected during the application of a static load. This, in order to make the results of the thermal analysis free from the sensitivity of the operator and to make the results as objective as possible, for defining the closest time of the linearity loss in the temperature-time function.

  13. STATIC TESTS OF UNCONVENTIONAL PROPULSION UNITS FOR ULTRALIGHT AIRPLANES

    Directory of Open Access Journals (Sweden)

    Martin Helmich

    2014-06-01

    Full Text Available This paper presents static tests of a new unconventional propulsion unit for small aviation airplanes. Our laboratory stand – a fan drive demonstrator – enables us to compare various design options. We performed experiments to verify the propulsion functionality and a measurement procedure to determine the available thrust of the propulsion unit and its dependence on engine speed. The results used for subsequent optimization include the operating parameters of the propulsion unit, and the temperature and velocity fields in parts of the air duct.

  14. Static Load Test on Instrumented Pile – Field Data and Numerical Simulations

    Directory of Open Access Journals (Sweden)

    Krasiński Adam

    2017-09-01

    Full Text Available Static load tests on foundation piles are generally carried out in order to determine load – the displacement characteristic of the pile head. For standard (basic engineering practices this type of test usually provides enough information. However, the knowledge of force distribution along the pile core and its division into the friction along the shaft and the resistance under the base can be very useful. Such information can be obtained by strain gage pile instrumentation [1]. Significant investigations have been completed on this technology, proving its utility and correctness [8], [10], [12]. The results of static tests on instrumented piles are not easy to interpret. There are many factors and processes affecting the final outcome. In order to understand better the whole testing process and soil-structure behavior some investigations and numerical analyses were done. In the paper, real data from a field load test on instrumented piles is discussed and compared with numerical simulation of such a test in similar conditions. Differences and difficulties in the results interpretation with their possible reasons are discussed. Moreover, the authors used their own analytical solution for more reliable determination of force distribution along the pile. The work was presented at the XVII French-Polish Colloquium of Soil and Rock Mechanics, Łódź, 28–30 November 2016.

  15. Small-Scale Quasi-Static Tests on Non-Slender Piles Situated in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo

    In the period from February 2009 till March 2011 a series of small-scale tests on pile foundations has been conducted at Aalborg University. In all the tests the piles have been exposed to quasi-static loading and all the tests have been conducted in a pressure tank. The objective of the tests has...... been to investigate the effect of pile diameter and length to diameter ratio on the soil response in sand for non-slender piles. Further, the tests have been conducted to calibrate a three-dimensional numerical model in the commercial program FLAC3D....

  16. USB environment measurements based on full-scale static engine ground tests

    Science.gov (United States)

    Sussman, M. B.; Harkonen, D. L.; Reed, J. B.

    1976-01-01

    Flow turning parameters, static pressures, surface temperatures, surface fluctuating pressures and acceleration levels were measured in the environment of a full-scale upper surface blowing (USB) propulsive lift test configuration. The test components included a flightworthy CF6-50D engine, nacelle, and USB flap assembly utilized in conjunction with ground verification testing of the USAF YC-14 Advanced Medium STOL Transport propulsion system. Results, based on a preliminary analysis of the data, generally show reasonable agreement with predicted levels based on model data. However, additional detailed analysis is required to confirm the preliminary evaluation, to help delineate certain discrepancies with model data, and to establish a basis for future flight test comparisons.

  17. Rectifier cabinet static breaker

    International Nuclear Information System (INIS)

    Costantino, R.A. Jr; Gliebe, R.J.

    1992-01-01

    A rectifier cabinet static breaker replaces a blocking diode pair with an SCR and the installation of a power transistor in parallel with the latch contactor to commutate the SCR to the off state. The SCR serves as a static breaker with fast turnoff capability providing an alternative way of achieving reactor scram in addition to performing the function of the replaced blocking diodes. The control circuitry for the rectifier cabinet static breaker includes on-line test capability and an LED indicator light to denote successful test completion. Current limit circuitry provides high-speed protection in the event of overload. 7 figs

  18. Rectifier cabinet static breaker

    Science.gov (United States)

    Costantino, Jr, Roger A.; Gliebe, Ronald J.

    1992-09-01

    A rectifier cabinet static breaker replaces a blocking diode pair with an SCR and the installation of a power transistor in parallel with the latch contactor to commutate the SCR to the off state. The SCR serves as a static breaker with fast turnoff capability providing an alternative way of achieving reactor scram in addition to performing the function of the replaced blocking diodes. The control circuitry for the rectifier cabinet static breaker includes on-line test capability and an LED indicator light to denote successful test completion. Current limit circuitry provides high-speed protection in the event of overload.

  19. Design and Demonstration of a Test-Rig for Static Performance-Studies of Permanent Magnet Couplings

    DEFF Research Database (Denmark)

    Högberg, Stig; Jensen, Bogi Bech; Bendixen, Flemming Buus

    2013-01-01

    The design and construction of an easy-to-use test-rig for permanent magnet couplings is presented. Static torque of permanent magnet couplings as a function of angular displacement is measured of permanent magnet couplings through an semi-automated test system. The test-rig is capable of measuring...

  20. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    Science.gov (United States)

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  1. Static Tension Tests on Axially Loaded Pile Segments in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    This paper provides laboratory test results of static axially loaded piles in sand. With a newly developed test setup, the pile-soil interface friction was investigated by using an open-ended steel pile segment with a diameter of 0.5 m. Use of a pile length of 1 m enabled the pile-soil interface...... friction to be analyzed at a given soil horizon while increasing the vertical effective stress in the sand. Test results obtained by this approach can be analyzed as single t-z curves and compared to predictions of unit shaft friction from current design methods for offshore foundations. The test results...... showed best agreement with the traditional design method given in the American Petroleum Institute (API) design code. When t-z curves obtained from the test results were compared to t-z curve formulations found in the literature, the Zhang formulation gave good predictions of the initial and post...

  2. Saturn V Second Stage (S-II) Ready for Static Test

    Science.gov (United States)

    1965-01-01

    Two workers are dwarfed by the five J-2 engines of the Saturn V second stage (S-II) as they make final inspections prior to a static test firing by North American Space Division. These five hydrogen -fueled engines produced one million pounds of thrust, and placed the Apollo spacecraft into earth orbit before departing for the moon. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  3. PV inverter test setup for European efficiency, static and dynamic MPPT efficiency evaluation

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Valentini, Massimo

    2008-01-01

    This paper concerns the evaluation of performance of grid-connected PV inverters in terms of conversion efficiency, European efficiency, static and dynamic MPP efficiency. Semi-automated tests were performed in the PV laboratory of the Institute of Energy Technology at the Aalborg University...... (Denmark) on a commercial transformerless PV inverter. Thanks to the available experimental test setups, that provide the required high measuring accuracy, and the developed PV simulator, which is required for MPPT performance evaluation, PV Inverters can be pretested before being tested by accredited...

  4. In-flight and ground testing of single event upset sensitivity in static RAMs

    International Nuclear Information System (INIS)

    Johansson, K.; Dyreklev, P.; Granbom, B.; Calvet, C.; Fourtine, S.; Feuillatre, O.

    1998-01-01

    This paper presents the results from in-flight measurements of single event upsets (SEU) in static random access memories (SRAM) caused by the atmospheric radiation environment at aircraft altitudes. The memory devices were carried on commercial airlines at high altitude and mainly high latitudes. The SEUs were monitored by a Component Upset Test Equipment (CUTE), designed for this experiment. The in flight results are compared to ground based testing with neutrons from three different sources

  5. Short-term static corrosion tests in lead-bismuth

    Science.gov (United States)

    Soler Crespo, L.; Martín Muñoz, F. J.; Gómez Briceño, D.

    2001-07-01

    Martensitic steels have been proposed to be used as structural materials and as spallation target window in hybrid systems devoted to the transmutation of radioactive waste of long life and high activity. However, their compatibility with lead-bismuth in the operating conditions of these systems depends on the existence of a protective layer such as an oxide film. The feasibility of forming and maintaining an oxide layer or maintaining a pre-oxidised one has been studied. Martensitic steel F82Hmod. (8% Cr) has been tested in lead-bismuth under static and isothermal conditions at 400°C and 600°C. In order to study the first stages of the interaction between the steel and the eutectic, short-term tests (100 and 665 h) have been carried out. Pre-oxidised and as-received samples have been tested in atmospheres with different oxidant potential. For low oxygen concentration in lead-bismuth due to unexpected oxygen consumption in the experimental device, dissolution of as-received F82Hmod. occurs and pre-oxidation does not prevent the material dissolution. For high oxygen concentration, the pre-oxidation layer seems to improve the feasibility of protecting stainless steels controlling the oxygen potential of lead-bismuth with a gas phase.

  6. Short-term static corrosion tests in lead-bismuth

    International Nuclear Information System (INIS)

    Soler Crespo, L.; Martin Munoz, F.J.; Gomez Briceno, D.

    2001-01-01

    Martensitic steels have been proposed to be used as structural materials and as spallation target window in hybrid systems devoted to the transmutation of radioactive waste of long life and high activity. However, their compatibility with lead-bismuth in the operating conditions of these systems depends on the existence of a protective layer such as an oxide film. The feasibility of forming and maintaining an oxide layer or maintaining a pre-oxidised one has been studied. Martensitic steel F82Hmod. (8% Cr) has been tested in lead-bismuth under static and isothermal conditions at 400 o C and 600 o C. In order to study the first stages of the interaction between the steel and the eutectic, short-term tests (100 and 665 h) have been carried out. Pre-oxidised and as-received samples have been tested in atmospheres with different oxidant potential. For low oxygen concentration in lead-bismuth due to unexpected oxygen consumption in the experimental device, dissolution of as-received F82Hmod. occurs and pre-oxidation does not prevent the material dissolution. For high oxygen concentration, the pre-oxidation layer seems to improve the feasibility of protecting stainless steels controlling the oxygen potential of lead-bismuth with a gas phase

  7. Study of a low-dose capsule filling process by dynamic and static tests for advanced process understanding.

    Science.gov (United States)

    Stranzinger, S; Faulhammer, E; Scheibelhofer, O; Calzolari, V; Biserni, S; Paudel, A; Khinast, J G

    2018-04-05

    Precise filling of capsules with doses in the mg-range requires a good understanding of the filling process. Therefore, we investigated the various process steps of the filling process by dynamic and static mode tests. Dynamic tests refer to filling of capsules in a regular laboratory dosator filling machine. Static tests were conducted using a novel filling system developed by us. Three grades of lactose excipients were filled into size 3 capsules with different dosing chamber lengths, nozzle diameters and powder bed heights, and, in the dynamic mode, with two filling speeds (500, 3000 caps/h). The influence of the gap at the bottom of the powder container on the fill weight and variability was assessed. Different gaps resulted in a change in fill weight in all materials, although in different ways. In all cases, the fill weight of highly cohesive Lactohale 220 increased when decreasing the gap. Furthermore, experiments with the stand-alone static test tool indicated that this very challenging powder could successfully be filled without any pre-compression in the range of 5 mg-20 mg with acceptable RSDs. This finding is of great importance since for very fine lactose powders high compression ratios (dosing-chamber-length-to-powder-bed height compression ratios) may result in jamming of the piston. Moreover, it shows that the static mode setup is suitable for studying fill weight and variability. Since cohesive powders, such as Lactohale 220, are hard to fill, we investigated the impact of vibration on the process. Interestingly, we found no correlation between the reported fill weight changes in dynamic mode at 3000 cph and static mode using similar vibration. However, we could show that vibrations during sampling in the static mode dramatically reduced fill weight variability. Overall, our results indicate that by fine-tuning instrumental settings even very challenging powders can be filled with a low-dose dosator capsule filling machine. This study is a

  8. Static electricity: A literature review

    Science.gov (United States)

    Crow, Rita M.

    1991-11-01

    The major concern with static electricity is its discharging in a flammable atmosphere which can explode and cause a fire. Textile materials can have their electrical resistivity decreased by the addition of antistatic finishes, imbedding conductive particles into the fibres or by adding metal fibers to the yarns. The test methods used in the studies of static electricity include measuring the static properties of materials, of clothed persons, and of the ignition energy of flammable gases. Surveys have shown that there is sparse evidence for fires definitively being caused by static electricity. However, the 'worst-case' philosophy has been adopted and a static electricity safety code is described, including correct grounding procedures and the wearing of anti-static clothing and footwear.

  9. EC static high-temperature leach test. Summary report of an European Community interlaboratory round robin

    International Nuclear Information System (INIS)

    Koennecke, R.; Kirsch, J.

    1985-01-01

    The results of an interlaboratory static high-temperature leach test conducted by the Commission of the European Communities in 1983 over a period of 9 months are compiled and statistically evaluated. A total of 12 laboratories - 10 from Member States of the EC and one from Finland and the USA - provided information concerning the test method and the analytical test results in the frame of a round robin test (RRT). All together these laboratories tested 366 waste from specimens of the borosilicate glass UK 209 containing simulated high-level radioactive waste. Leach tests were performed on the basis of the ''Document on the EC static high-temperature leach test method'' in autoclaves at leaching temperatures of 90 0 C, 110 0 C, 150 0 C, and 190 0 C over time periods of 3,7,14,28 and 56 days using dionized water as leachant. The resulting leachates were analysed for the elemental concentrations of Si,B,Sr,Nd and Cs by all laboratories and for the concentrations of the optional elements Na, Al,Ce,Mo,Cr,Fe,Li,Mg and Zn by some of the participating laboratories. Additionally, the F content of the blank leachates was analysed by all laboratories

  10. Fairchild Stratos Division's Type II prototype lockhopper valve: METC Prototype Test Valve No. F-1 prototype lockhopper valve-testing and development project. Static test report

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D. R.; Cutright, R. L.; Griffith, R. A.; Loomis, R. B.; Maxfield, D. A.; Moritz, R. S.

    1981-10-01

    METC Prototype Test Valve No. F-1 is a hybrid design, based on a segmented ball termed a visor valve, developed and manufactured by Fairchild Stratos Division under contract to the Department of Energy. The valve uses a visor arm that rotates into position and then translates to seal. This valve conditionally completed static testing at METC with clean gas to pressures of 1600 psig and internal valve temperatures to 600/sup 0/F. External leakage was excessive due to leakage through the stuffing box, purge fittings, external bolts, and other assemblies. The stuffing box was repacked several times and redesigned midway through the testing, but external leakage was still excessive. Internal leakage through the seats, except for a few anomalies, was very low throughout the 2409 cycles of testing. As shown by the low internal leakage, the visor valve concept appears to have potential for lock-hopper valve applications. The problems that are present with METC Prototype Test Valve No. F-1 are in the seals, which are equivalent to the shaft and bonnet seals in standard valve designs. The operating conditions at these seals are well within the capabilities of available seal designs and materials. Further engineering and minor modifications should be able to resolve the problems identified during static testing.

  11. Hubble Diagram Test of Expanding and Static Cosmological Models: The Case for a Slowly Expanding Flat Universe

    Directory of Open Access Journals (Sweden)

    Laszlo A. Marosi

    2013-01-01

    Full Text Available We present a new redshift (RS versus photon travel time ( test including 171 supernovae RS data points. We extended the Hubble diagram to a range of z = 0,0141–8.1 in the hope that at high RSs, the fitting of the calculated RS/ diagrams to the observed RS data would, as predicted by different cosmological models, set constraints on alternative cosmological models. The Lambda cold dark matter (ΛCDM, the static universe model, and the case for a slowly expanding flat universe (SEU are considered. We show that on the basis of the Hubble diagram test, the static and the slowly expanding models are favored.

  12. Hemodynamic Changes After Static and Dynamic Exercises and Treadmill Stress Test; Different Patterns in Patients with Primary Benign Exertional Headache?

    Directory of Open Access Journals (Sweden)

    Mohsen Rostami

    2012-06-01

    Full Text Available The pathophysiology of primary benign exertional headache (EH is not still clearly defined. Some researchers have suggested an impaired vascular response as the etiology of this disorder. In this study we investigated whether there are any differences in blood pressure (BP and heart rate (HR of the subjects in course of the static and dynamic exercises and the treadmill stress test between those with and without EH. From university students, 22 patients with EH (mean age: 19.8 ± 2.10, Female to Male: 7:15 and 20 normal subjects (mean age: 19.3 ± 1.97, Female: Male: 8:12 were recruited. All the subjects performed the static and dynamic exercises at 30 and 20 percent of the maximal voluntary contraction (MVC and Bruce treadmill stress test according to the standard protocols. HR and BP of all the cases at the baseline and during and immediately after each test were measured. No significant difference was found between the mean rise of HR, systolic and diastolic BP of the subjects with and without EH in static and dynamic exercises and also treadmill stress test. It seems that between those with and without EH, there is no significant difference in rise of HR and BP response to static and dynamic exercises and treadmill stress test. Further studies are required to find the pathophysiology and risk factors of EH.

  13. Hemodynamic changes after static and dynamic exercises and treadmill stress test; different patterns in patients with primary benign exertional headache?

    Science.gov (United States)

    Kordi, Ramin; Mazaheri, Reza; Rostami, Mohsen; Mansournia, Mohammad Ali

    2012-01-01

    The pathophysiology of primary benign exertional headache (EH) is not still clearly defined. Some researchers have suggested an impaired vascular response as the etiology of this disorder. In this study we investigated whether there are any differences in blood pressure (BP) and heart rate (HR) of the subjects in course of the static and dynamic exercises and the treadmill stress test between those with and without EH. From university students, 22 patients with EH (mean age: 19.8 ± 2.10, Female to Male: 7:15) and 20 normal subjects (mean age: 19.3 ± 1.97, Female: Male: 8:12) were recruited. All the subjects performed the static and dynamic exercises at 30 and 20 percent of the maximal voluntary contraction (MVC) and Bruce treadmill stress test according to the standard protocols. HR and BP of all the cases at the baseline and during and immediately after each test were measured. No significant difference was found between the mean rise of HR, systolic and diastolic BP of the subjects with and without EH in static and dynamic exercises and also treadmill stress test. It seems that between those with and without EH, there is no significant difference in rise of HR and BP response to static and dynamic exercises and treadmill stress test. Further studies are required to find the pathophysiology and risk factors of EH.

  14. Martian Atmospheric Pressure Static Charge Elimination Tool

    Science.gov (United States)

    Johansen, Michael R.

    2014-01-01

    A Martian pressure static charge elimination tool is currently in development in the Electrostatics and Surface Physics Laboratory (ESPL) at NASA's Kennedy Space Center. In standard Earth atmosphere conditions, static charge can be neutralized from an insulating surface using air ionizers. These air ionizers generate ions through corona breakdown. The Martian atmosphere is 7 Torr of mostly carbon dioxide, which makes it inherently difficult to use similar methods as those used for standard atmosphere static elimination tools. An initial prototype has been developed to show feasibility of static charge elimination at low pressure, using corona discharge. A needle point and thin wire loop are used as the corona generating electrodes. A photo of the test apparatus is shown below. Positive and negative high voltage pulses are sent to the needle point. This creates positive and negative ions that can be used for static charge neutralization. In a preliminary test, a floating metal plate was charged to approximately 600 volts under Martian atmospheric conditions. The static elimination tool was enabled and the voltage on the metal plate dropped rapidly to -100 volts. This test data is displayed below. Optimization is necessary to improve the electrostatic balance of the static elimination tool.

  15. Modeling of the Jacked Pile Static Load Test with PLAX 3D

    Directory of Open Access Journals (Sweden)

    Tautvydas Statkus

    2016-12-01

    Full Text Available In this article jacked pile installation technology and its current processes, altering the base physical and mechanical characteristics are discussed. For the jacked pile static load test simulation Plax 3D software was selected, the opportunities and developments were described. Model building, materials, models, model geometry, finite elements, boundary conditions and assumptions adopted in addressing problems described in detail. Three different tasks formulated and load-settlement dependence a comparison of the results with the experiment given. Conclusions are formulated according to the modeling results.

  16. Safety prediction for basic components of safety-critical software based on static testing

    International Nuclear Information System (INIS)

    Son, H.S.; Seong, P.H.

    2000-01-01

    The purpose of this work is to develop a safety prediction method, with which we can predict the risk of software components based on static testing results at the early development stage. The predictive model combines the major factor with the quality factor for the components, which are calculated based on the measures proposed in this work. The application to a safety-critical software system demonstrates the feasibility of the safety prediction method. (authors)

  17. Static Feed Water Electrolysis Subsystem Testing and Component Development

    Science.gov (United States)

    Koszenski, E. P.; Schubert, F. H.; Burke, K. A.

    1983-01-01

    A program was carried out to develop and test advanced electrochemical cells/modules and critical electromechanical components for a static feed (alkaline electrolyte) water electrolysis oxygen generation subsystem. The accomplishments were refurbishment of a previously developed subsystem and successful demonstration for a total of 2980 hours of normal operation; achievement of sustained one-person level oxygen generation performance with state-of-the-art cell voltages averaging 1.61 V at 191 ASF for an operating temperature of 128F (equivalent to 1.51V when normalized to 180F); endurance testing and demonstration of reliable performance of the three-fluid pressure controller for 8650 hours; design and development of a fluid control assembly for this subsystem and demonstration of its performance; development and demonstration at the single cell and module levels of a unitized core composite cell that provides expanded differential pressure tolerance capability; fabrication and evaluation of a feed water electrolyte elimination five-cell module; and successful demonstration of an electrolysis module pressurization technique that can be used in place of nitrogen gas during the standby mode of operation to maintain system pressure and differential pressures.

  18. Safety prediction for basic components of safety critical software based on static testing

    International Nuclear Information System (INIS)

    Son, H.S.; Seong, P.H.

    2001-01-01

    The purpose of this work is to develop a safety prediction method, with which we can predict the risk of software components based on static testing results at the early development stage. The predictive model combines the major factor with the quality factor for the components, both of which are calculated based on the measures proposed in this work. The application to a safety-critical software system demonstrates the feasibility of the safety prediction method. (authors)

  19. Investigation of two pitot-static tubes at supersonic speeds

    Science.gov (United States)

    Hasel, Lowell E; Coletti, Donald E

    1948-01-01

    The results of tests at a Mach number of 1.94 of an ogives-nose cylindrical pitot-static tube and similar tests at Mach numbers of 1.93 and 1.62 of a service pitot-static tube to determine body static pressures and indicated Mach numbers are presented and discussed. The radial pressure distribution on the cylindrical bodies is compared with that calculated by an approximate theory.

  20. Static and dynamic testing of a damaged post tensioned concrete beam

    Directory of Open Access Journals (Sweden)

    Limongelli M.P.

    2015-01-01

    Full Text Available In this paper are reported the results of an experimental campaign carried out on a post tensioned concrete beam with the aim of investigating the possibility to detect early warning signs of deterioration basing on static and/or dynamic tests. The beam was tested in several configurations aimed to reproduce several different phases of the ‘life’ of the beam: the original undamaged state, increasing loss of tension in the post tensioning cables, a strengthening intervention carried out by means of a second tension cable, formation of further cracks on the strengthened beam. Responses of the beam were measured by an extensive set of instruments consisting of accelerometers, inclinometers, displacement transducers, strain gauges and optical fibres. The paper discusses the tests program and the dynamic characterization of the beam in the different damage scenarios. The modal properties of the beam in the different phases were recovered basing on the responses recorded on the beam during sine-sweep and impact hammer tests. The variation of the first modal frequency was studied to investigate the sensitivity of this parameter to both the cracking of the concrete section and the tension in the cables and also to compare results given by different types of experimental tests.

  1. Aerodynamic Tests on a Static California Sea Lion Flipper

    Science.gov (United States)

    Kulkarni, Aditya A.; Leftwich, Megan C.

    2017-11-01

    Unlike most biological swimmers that use BCF swimming, the California sea lion relies on its foreflippers for thrust production. This unique swimming style, which lacks a characteristic oscillation frequency, allows the sea lion to leave less traceable wake while also producing high amounts of thrust. While the swimming energetics of the animal have been studied, almost nothing is known about the fluid dynamics of the system. To overcome this lack of basic understanding, a three-dimensional model of the flipper was developed using structured light-based scanners. Cross sections of the flipper model resemble the shape of the airfoils typically found in wings with thickness ratios, 11% - 37%. Wind tunnel testing conducted on static flipper revealed that positive lift was being generated at negative angles of attack. This is hypothesized to help the sea lions considerably in perform tight maneuvers with a small turning radius. The wake structure downstream of the flipper was captured using Particle Image Velocimetry (PIV).

  2. Static tilt tests of a full-sized cylindrical liquid storage tank model

    International Nuclear Information System (INIS)

    Sakai, F.

    1988-01-01

    This paper is explaining a static tilt test with a full-scaled tank model, the objects of which are the above-ground type LNG,LPG and oil storage tanks. Main points of view to investigate are as follows: Stress and deformation at each part of the tank wall, the bottom plate and the anchor straps in case that the anchor straps are very effective; Behavior in case that the anchor straps are not very effective; Behavior in case of no anchors; Influence of the roof above the shell; and Influence of the foundation rigidity under the bottom plate

  3. Static, Fire and Fatigue Tests of Ultra High-Strength Fibre Reinforced Concrete and Ribbed Bars

    DEFF Research Database (Denmark)

    Hansen, Lars Pilegaard; Heshe, Gert

    2001-01-01

    A new building system has been developed during the last 10 years. This new system consists of a column / slab system with 6 x 6 m distance between the columns. The slabs are precast concrete elements of size 2.9 x 5.9 m connected through joints of ultra high strength fibre reinforced concrete...... - Densit Joint Cast ®. Also the connections between the columns and the slabs are made of this very strong concrete material. The paper describes some of the static tests carried out as well as some fire tests. Further, 2 chapters deal with some fatigue tests of the reinforcing bars as well as some fatigue...

  4. THE EXPERIENCE OF COMPARISON OF STATIC SECURITY CODE ANALYZERS

    Directory of Open Access Journals (Sweden)

    Alexey Markov

    2015-09-01

    Full Text Available This work presents a methodological approach to comparison of static security code analyzers. It substantiates the comparison of the static analyzers as to efficiency and functionality indicators, which are stipulated in the international regulatory documents. The test data for assessment of static analyzers efficiency is represented by synthetic sets of open-source software, which contain vulnerabilities. We substantiated certain criteria for quality assessment of the static security code analyzers subject to standards NIST SP 500-268 and SATEC. We carried out experiments that allowed us to assess a number of the Russian proprietary software tools and open-source tools. We came to the conclusion that it is of paramount importance to develop Russian regulatory framework for testing software security (firstly, for controlling undocumented features and evaluating the quality of static security code analyzers.

  5. Criteria for initiation of delamination in quasi-static punch-shear tests of a carbon-fiber composite material.

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Eric Brian [Sandia National Lab. (SNL-CA), Livermore, CA (United States); English, Shawn Allen [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Briggs, Timothy [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-09-01

    V arious phenomenological delamination initiation criteria are analyzed in quasi - static punch - shear tests conducted on six different geometries. These six geometries are modeled and analyzed using elastic, large - deformation finite element analysis. Analysis output is post - processed to assess different delamination initiation criteria, and their applicability to each of the geometries. These criteria are compared to test results to assess whether or not they are appropriate based on what occurred in testing. Further, examinations of CT scans and ultrasonic images o f test specimens are conducted in the appendix to determine the sequence of failure in each test geometry.

  6. Prediction of flyover jet noise spectra from static tests

    Science.gov (United States)

    Michel, U.; Michalke, A.

    A scaling law for predicting the overall flyover noise of a single stream shock-free circular jet from static experiments is outlined. It is valid for isothermal and hot jets. It assumes that the jet flow and turbulence field are axially stretched in flight. Effects of the boundary layer within the nozzle and along the engine nacelle are neglected. The scaling laws for the power spectral density and spectra with constant relative bandwidth can be derived. In order to compare static and inflight directivities, the far field point relative to the source position must be denoted by the emission angle and the wave normal distance. From the solution of the convective Lighthill equation in a coordinate system fixed to the jet nozzle (wind tunnel case), the power spectral density of sound pressure at a given frequency is found. Predictions for Aerotrain compare well with measured values.

  7. Prediction of acid mine drainage generation potential of various lithologies using static tests: Etili coal mine (NW Turkey) as a case study.

    Science.gov (United States)

    Yucel, Deniz Sanliyuksel; Baba, Alper

    2016-08-01

    The Etili neighborhood in Can County (northwestern Turkey) has large reserves of coal and has been the site of many small- to medium-scale mining operations since the 1980s. Some of these have ceased working while others continue to operate. Once activities cease, the mining facilities and fields are usually abandoned without rehabilitation. The most significant environmental problem is acid mine drainage (AMD). This study was carried out to determine the acid generation potential of various lithological units in the Etili coal mine using static test methods. Seventeen samples were selected from areas with high acidic water concentrations: from different alteration zones belonging to volcanic rocks, from sedimentary rocks, and from coals and mine wastes. Static tests (paste pH, standard acid-base accounting, and net acid generation tests) were performed on these samples. The consistency of the static test results showed that oxidation of sulfide minerals, especially pyrite-which is widely found not only in the alteration zones of volcanic rocks but also in the coals and mine wastes-is the main factor controlling the generation of AMD in this mine. Lack of carbonate minerals in the region also increases the occurrence of AMD.

  8. Instrumented static and dynamic balance assessment after stroke using Wii Balance Boards: reliability and association with clinical tests.

    Science.gov (United States)

    Bower, Kelly J; McGinley, Jennifer L; Miller, Kimberly J; Clark, Ross A

    2014-01-01

    The Wii Balance Board (WBB) is a globally accessible device that shows promise as a clinically useful balance assessment tool. Although the WBB has been found to be comparable to a laboratory-grade force platform for obtaining centre of pressure data, it has not been comprehensively studied in clinical populations. The aim of this study was to investigate the measurement properties of tests utilising the WBB in people after stroke. Thirty individuals who were more than three months post-stroke and able to stand unsupported were recruited from a single outpatient rehabilitation facility. Participants performed standardised assessments incorporating the WBB and customised software (static stance with eyes open and closed, static weight-bearing asymmetry, dynamic mediolateral weight shifting and dynamic sit-to-stand) in addition to commonly employed clinical tests (10 Metre Walk Test, Timed Up and Go, Step Test and Functional Reach) on two testing occasions one week apart. Test-retest reliability and construct validity of the WBB tests were investigated. All WBB-based outcomes were found to be highly reliable between testing occasions (ICC  = 0.82 to 0.98). Correlations were poor to moderate between WBB variables and clinical tests, with the strongest associations observed between task-related activities, such as WBB mediolateral weight shifting and the Step Test. The WBB, used with customised software, is a reliable and potentially useful tool for the assessment of balance and weight-bearing asymmetry following stroke. Future research is recommended to further investigate validity and responsiveness.

  9. A computational methodology for a micro launcher engine test bench using a combined linear static and dynamic in frequency response analysis

    Directory of Open Access Journals (Sweden)

    Ion DIMA

    2017-03-01

    Full Text Available This article aims to provide a quick methodology to determine the critical values of the forces, displacements and stress function of frequency, under a combined linear static (101 Solution - Linear Static and dynamic load in frequency response (108 Solution - Frequency Response, Direct Method, applied to a micro launcher engine test bench, using NASTRAN 400 Solution - Implicit Nonlinear. NASTRAN/PATRAN software is used. Practically in PATRAN the preprocessor has to define a linear or nonlinear static load at step 1 and a dynamic in frequency response load (time dependent at step 2. In Analyze the following options are chosen: for Solution Type Implicit Nonlinear Solution (SOL 400 is selected, for Subcases Static Load and Transient Dynamic is chosen and for Subcase Select the two cases static and dynamic will be selected. NASTRAN solver will overlap results from static analysis with the dynamic analysis. The running time will be reduced three times if using Krylov solver. NASTRAN SYSTEM (387 = -1 instruction is used in order to activate Krylov option. Also, in Analysis the OP2 Output Format shall be selected, meaning that in bdf NASTRAN input file the PARAM POST 1 instruction shall be written. The structural damping can be defined in two different ways: either at the material card or using the PARAM, G, 0.05 instruction (in this example a damping coefficient by 5% was used. The SDAMPING instruction in pair with TABDMP1 work only for dynamic in frequency response, modal method, or in direct method with viscoelastic material, not for dynamic in frequency response, direct method (DFREQ, with linear elastic material. The Direct method – DFREQ used in this example is more accurate. A set in translation of boundary conditions was used and defined at the base of the test bench.

  10. Failure Behaviour of Aluminium/CFRP Laminates with Varying Fibre Orientation in Quasi-static Indentation Test

    Science.gov (United States)

    Romli, N. K.; Rejab, M. R. M.; Bachtiar, D.; Siregar, J.; Rani, M. F.; Salleh, Salwani Mohd; Merzuki, M. N. M.

    2018-03-01

    The response of the aluminium/carbon laminate was examined by an experimental work. The investigation on fibre metal laminate behaviour was done through an indentation test in a quasi-static loading. The hybrid laminate was fabricated by a compression moulding technique and used two types of carbon fibre orientations; plain weave and unidirectional. The plain weave orientation is dry fibre, and unidirectional orientation is prepreg type fibre. The plain weave carbon fibre and aluminium alloy 2024-0 was laminated by using thermoset epoxy while the unidirectional carbon fibre was pressed by using a hot press machine and cured under a specific temperature and pressure. A compression moulding technique was used for the FML fabrication. The aluminium sheet metal has been roughening by a metal sanding method which to improve the bonding between the fibre and metal layer. The main objective of this paper is to determine the failure response of the laminate under five variation of the crosshead speeds in the quasi-static loading. Based on the experimental data of the test, the result of 1 mm/min in the plain weave CFRP has lower loading than unidirectional fibre which the value of both was 4.11 kN and 4.69 kN, respectively.

  11. Moment measurements in dynamic and quasi-static spine segment testing using eccentric compression are susceptible to artifacts based on loading configuration.

    Science.gov (United States)

    Van Toen, Carolyn; Carter, Jarrod W; Oxland, Thomas R; Cripton, Peter A

    2014-12-01

    The tolerance of the spine to bending moments, used for evaluation of injury prevention devices, is often determined through eccentric axial compression experiments using segments of the cadaver spine. Preliminary experiments in our laboratory demonstrated that eccentric axial compression resulted in "unexpected" (artifact) moments. The aim of this study was to evaluate the static and dynamic effects of test configuration on bending moments during eccentric axial compression typical in cadaver spine segment testing. Specific objectives were to create dynamic equilibrium equations for the loads measured inferior to the specimen, experimentally verify these equations, and compare moment responses from various test configurations using synthetic (rubber) and human cadaver specimens. The equilibrium equations were verified by performing quasi-static (5 mm/s) and dynamic experiments (0.4 m/s) on a rubber specimen and comparing calculated shear forces and bending moments to those measured using a six-axis load cell. Moment responses were compared for hinge joint, linear slider and hinge joint, and roller joint configurations tested at quasi-static and dynamic rates. Calculated shear force and bending moment curves had similar shapes to those measured. Calculated values in the first local minima differed from those measured by 3% and 15%, respectively, in the dynamic test, and these occurred within 1.5 ms of those measured. In the rubber specimen experiments, for the hinge joint (translation constrained), quasi-static and dynamic posterior eccentric compression resulted in flexion (unexpected) moments. For the slider and hinge joints and the roller joints (translation unconstrained), extension ("expected") moments were measured quasi-statically and initial flexion (unexpected) moments were measured dynamically. In the cadaver experiments with roller joints, anterior and posterior eccentricities resulted in extension moments, which were unexpected and expected, for those

  12. Static Test for a Gravitational Force Coupled to Type 2 YBCO Superconductors

    Science.gov (United States)

    Li, Ning; Noever, David; Robertson, Tony; Koczor, Ron; Brantley, Whitt

    1997-01-01

    As a Bose condensate, superconductors provide novel conditions for revisiting previously proposed couplings between electromagnetism and gravity. Strong variations in Cooper pair density, large conductivity and low magnetic permeability define superconductive and degenerate condensates without the traditional density limits imposed by the Fermi energy (approx. 10(exp -6) g cc. Recent experiments have reported anomalous weight loss for a test mass suspended above a rotating type II, YBCO superconductor, with the percentage change (0.05 - 2.1 %) independent of the test mass' chemical composition and diamagnetic properties. A variation of 5 parts per 10' was reported above a stationary (non-rotating) superconductor. In experiments using a sensitive gravimeter, bulk YBCO superconductors were stably levitated in a DC magnetic field. Changes in acceleration were measured to be less than 2 parts in 108 of the normal gravitational acceleration. This result puts new limits on the strength and range of the proposed coupling between static superconductors and gravity.

  13. Computer-assisted static/dynamic renal imaging: a screening test for renovascular hypertension

    International Nuclear Information System (INIS)

    Keim, H.J.; Johnson, P.M.; Vaughan, E.D. Jr.; Beg, K.; Follett, D.A.; Freeman, L.M.; Laragh, J.H.

    1979-01-01

    Computer-assisted static/dynamic renal imaging with [ 197 Hg] chlormerodrin and [/sup 99m/Tc] pertechnetate was evaluated prospectively as a screening test for renovascular hypertension. Results are reported for 51 patients: 33 with benign essential hypertension and 18 with renovascular hypertension, and for 21 normal controls. All patients underwent renal arteriography. Patients with significant obesity, renal insufficiency, or renoparenchymal disease were excluded from this study. Independent visual analyses of renal gamma images and time-activity transit curves identified 17 of the 18 patients with renovascular hypertension; one study was equivocal. There were five equivocal and three false-positive results in the essential hypertension and normal control groups. The sensitivity of the method was 94% and the specificity 85%. Since the prevalence of the renovascular subset of hypertension is approximately 5%, the predictive value is only 25%. Inclusion of computer-generated data did not improve this result. Accordingly, this method is not recommended as a primary screening test for renovascular hypertension

  14. Instrumented static and dynamic balance assessment after stroke using Wii Balance Boards: reliability and association with clinical tests.

    Directory of Open Access Journals (Sweden)

    Kelly J Bower

    Full Text Available The Wii Balance Board (WBB is a globally accessible device that shows promise as a clinically useful balance assessment tool. Although the WBB has been found to be comparable to a laboratory-grade force platform for obtaining centre of pressure data, it has not been comprehensively studied in clinical populations. The aim of this study was to investigate the measurement properties of tests utilising the WBB in people after stroke.Thirty individuals who were more than three months post-stroke and able to stand unsupported were recruited from a single outpatient rehabilitation facility. Participants performed standardised assessments incorporating the WBB and customised software (static stance with eyes open and closed, static weight-bearing asymmetry, dynamic mediolateral weight shifting and dynamic sit-to-stand in addition to commonly employed clinical tests (10 Metre Walk Test, Timed Up and Go, Step Test and Functional Reach on two testing occasions one week apart. Test-retest reliability and construct validity of the WBB tests were investigated.All WBB-based outcomes were found to be highly reliable between testing occasions (ICC  = 0.82 to 0.98. Correlations were poor to moderate between WBB variables and clinical tests, with the strongest associations observed between task-related activities, such as WBB mediolateral weight shifting and the Step Test.The WBB, used with customised software, is a reliable and potentially useful tool for the assessment of balance and weight-bearing asymmetry following stroke. Future research is recommended to further investigate validity and responsiveness.

  15. Static and Dynamic Friction Behavior of Candidate High Temperature Airframe Seal Materials

    Science.gov (United States)

    Dellacorte, C.; Lukaszewicz, V.; Morris, D. E.; Steinetz, B. M.

    1994-01-01

    The following report describes a series of research tests to evaluate candidate high temperature materials for static to moderately dynamic hypersonic airframe seals. Pin-on-disk reciprocating sliding tests were conducted from 25 to 843 C in air and hydrogen containing inert atmospheres. Friction, both dynamic and static, was monitored and serves as the primary test measurement. In general, soft coatings lead to excessive static friction and temperature affected friction in air environments only.

  16. Observing the Forces Involved in Static Friction under Static Situations

    Science.gov (United States)

    Kaplan, Daniel

    2013-01-01

    Static friction is an important concept in introductory physics. Later in the year students apply their understanding of static friction under more complex conditions of static equilibrium. Traditional lab demonstrations in this case involve exceeding of the maximum level of static friction, resulting in the "onset of motion." (Contains…

  17. A STUDY OF DISPLACEMENT-LEVEL DEPENDENCY OF VERTICAL STIFFNESS OF PILE - COMPARISONS BETWEEN STATIC LOADING TEST AND MEASUREMENTS DURING TRAIN PASSING -

    Science.gov (United States)

    Nihei, Tatsuya; Nishioka, Hidetoshi; Kawamura, Chikara; Nishimura, Masahiro; Edamatsu, Masayuki; Koda, Masayuki

    In order to introduce the performance based design of pile foundation, vertical stiffness of pile is one of the important design factors. Although it had been es timated the vertical stiffness of pile had the displacement-level dependency, it had been not clarified. We compared the vertical stiffness of pile measured by two loading conditions at pile foundation of the railway viaduct. Firstly, we measured the vertical stiffness at static loading test under construction of the viaduct. Secondly, we measured the vertical stiffness at the time of train passing. So, we recognized that the extrapolation of the displacement level dependency in static loading test could evaluate the vertical stiffness of pile during train passing.

  18. Relationship between the Berg Balance Scale and Static Balance Test in Hemiplegic Patients with Stroke

    OpenAIRE

    Suzuki, Makoto; Fujisawa, Hiroyuki; Machida, Yooichiro; Minakata, Shin

    2013-01-01

    [Purpose] The purpose of this study was to analyze the relationship between results of the Berg Balance Scale (BBS) and Static Balance Test (SBT) in hemiplegic patients with stroke. [Subjects] The subjects were 39 hemiplegic patients (25 men, 14 women; mean age, 69.4 ? 11.0?years) with stroke that had occurred within the preceding 6 months and who had good understanding of verbal instructions. [Methods] The SBT consists of five posture-holding tasks (sitting, stride standing, close standing, ...

  19. Standard test method for static leaching of monolithic waste forms for disposal of radioactive waste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a measure of the chemical durability of a simulated or radioactive monolithic waste form, such as a glass, ceramic, cement (grout), or cermet, in a test solution at temperatures <100°C under low specimen surface- area-to-leachant volume (S/V) ratio conditions. 1.2 This test method can be used to characterize the dissolution or leaching behaviors of various simulated or radioactive waste forms in various leachants under the specific conditions of the test based on analysis of the test solution. Data from this test are used to calculate normalized elemental mass loss values from specimens exposed to aqueous solutions at temperatures <100°C. 1.3 The test is conducted under static conditions in a constant solution volume and at a constant temperature. The reactivity of the test specimen is determined from the amounts of components released and accumulated in the solution over the test duration. A wide range of test conditions can be used to study material behavior, includin...

  20. PEBBLES Simulation of Static Friction and New Static Friction Benchmark

    International Nuclear Information System (INIS)

    Cogliati, Joshua J.; Ougouag, Abderrafi M.

    2010-01-01

    Pebble bed reactors contain large numbers of spherical fuel elements arranged randomly. Determining the motion and location of these fuel elements is required for calculating certain parameters of pebble bed reactor operation. This paper documents the PEBBLES static friction model. This model uses a three dimensional differential static friction approximation extended from the two dimensional Cundall and Strack model. The derivation of determining the rotational transformation of pebble to pebble static friction force is provided. A new implementation for a differential rotation method for pebble to container static friction force has been created. Previous published methods are insufficient for pebble bed reactor geometries. A new analytical static friction benchmark is documented that can be used to verify key static friction simulation parameters. This benchmark is based on determining the exact pebble to pebble and pebble to container static friction coefficients required to maintain a stable five sphere pyramid.

  1. Static capacity of laterally pre-cycled monopiles in dense sand

    DEFF Research Database (Denmark)

    Nicolai, Giulio; Ibsen, Lars Bo

    This work aims to investigate the change in static capacity of monopiles due to cyclic lateral loading. Results from small-scale tests on a monopile model in dense saturated sand are presented. Three series of tests were carried out to study the response of the monopile to different cyclic lateral...... loading conditions. A formulation to predict the change in static capacity is proposed and applied to confirm the tests results....

  2. Comparison of Analysis with Test for Static Loading of Two Hypersonic Inflatable Aerodynamic Decelerator Concepts

    Science.gov (United States)

    Lyle, Karen H.

    2015-01-01

    Acceptance of new spacecraft structural architectures and concepts requires validated design methods to minimize the expense involved with technology demonstration via flight-testing. Hypersonic Inflatable Aerodynamic Decelerator (HIAD) architectures are attractive for spacecraft deceleration because they are lightweight, store compactly, and utilize the atmosphere to decelerate a spacecraft during entry. However, designers are hesitant to include these inflatable approaches for large payloads or spacecraft because of the lack of flight validation. This publication summarizes results comparing analytical results with test data for two concepts subjected to representative entry, static loading. The level of agreement and ability to predict the load distribution is considered sufficient to enable analytical predictions to be used in the design process.

  3. USB environment measurements based on full-scale static engine ground tests. [Upper Surface Blowing for YC-14

    Science.gov (United States)

    Sussman, M. B.; Harkonen, D. L.; Reed, J. B.

    1976-01-01

    Flow turning parameters, static pressures, surface temperatures, surface fluctuating pressures and acceleration levels were measured in the environment of a full-scale upper surface blowing (USB) propulsive-lift test configuration. The test components included a flightworthy CF6-50D engine, nacelle and USB flap assembly utilized in conjunction with ground verification testing of the USAF YC-14 Advanced Medium STOL Transport propulsion system. Results, based on a preliminary analysis of the data, generally show reasonable agreement with predicted levels based on model data. However, additional detailed analysis is required to confirm the preliminary evaluation, to help delineate certain discrepancies with model data and to establish a basis for future flight test comparisons.

  4. Static and dynamic balance of children and adolescents with sensorineural hearing loss.

    Science.gov (United States)

    Melo, Renato de Souza; Marinho, Sônia Elvira Dos Santos; Freire, Maryelly Evelly Araújo; Souza, Robson Arruda; Damasceno, Hélio Anderson Melo; Raposo, Maria Cristina Falcão

    2017-01-01

    To assess the static and dynamic balance performance of students with normal hearing and with sensorineural hearing loss. A cross-sectional study assessing 96 students, 48 with normal hearing and 48 with sensorineural hearing loss of both sexes, aged 7 and 18 years. To evaluate static balance, Romberg, Romberg-Barré and Fournier tests were used; and for the dynamic balance, we applied the Unterberger test. Hearing loss students showed more changes in static and dynamic balance as compared to normal hearing, in all tests used (pRomberg, Romberg-Barré, Fournier and Unterberger test p values were, respectively, p=0.004, pRomberg, Romberg-Barré and Fournier tests were, respectively, p=0.007, pRomberg, Romberg-Barré, Fournier and Unterberger tests were p=0.002, pRomberg-Barré, Fournier and Unterberger tests were, respectively, p=0.037, p<0.001 and p=0.037. Hearing-loss students showed more changes in static and dynamic balance comparing to normal hearing of same sex and age groups.

  5. Static and fatigue experimental tests on a full scale fuselage panel and FEM analyses

    Directory of Open Access Journals (Sweden)

    Raffaele Sepe

    2016-02-01

    Full Text Available A fatigue test on a full scale panel with complex loading condition and geometry configuration has been carried out using a triaxial test machine. The demonstrator is made up of two skins which are linked by a transversal butt-joint, parallel to the stringer direction. A fatigue load was applied in the direction normal to the longitudinal joint, while a constant load was applied in the longitudinal joint direction. The test panel was instrumented with strain gages and previously quasi-static tests were conducted to ensure a proper load transferring to the panel. In order to support the tests, geometric nonlinear shell finite element analyses were conducted to predict strain and stress distributions. The demonstrator broke up after about 177000 cycles. Subsequently, a finite element analysis (FEA was carried out in order to correlate failure events; due to the biaxial nature of the fatigue loads, Sines criterion was used. The analysis was performed taking into account the different materials by which the panel is composed. The numerical results show a good correlation with experimental data, successfully predicting failure locations on the panel.

  6. Technology advancement of the static feed water electrolysis process

    Science.gov (United States)

    Schubert, F. H.; Wynveen, R. A.

    1977-01-01

    A program to advance the technology of oxygen- and hydrogen-generating subsystems based on water electrolysis was studied. Major emphasis was placed on static feed water electrolysis, a concept characterized by low power consumption and high intrinsic reliability. The static feed based oxygen generation subsystem consists basically of three subassemblies: (1) a combined water electrolysis and product gas dehumidifier module; (2) a product gas pressure controller and; (3) a cyclically filled water feed tank. Development activities were completed at the subsystem as well as at the component level. An extensive test program including single cell, subsystem and integrated system testing was completed with the required test support accessories designed, fabricated, and assembled. Mini-product assurance activities were included throughout all phases of program activities. An extensive number of supporting technology studies were conducted to advance the technology base of the static feed water electrolysis process and to resolve problems.

  7. Static and dynamic balance of children and adolescents with sensorineural hearing loss

    OpenAIRE

    Melo, Renato de Souza; Marinho, Sônia Elvira dos Santos; Freire, Maryelly Evelly Araújo; Souza, Robson Arruda; Damasceno, Hélio Anderson Melo; Raposo, Maria Cristina Falcão

    2017-01-01

    ABSTRACT Objective To assess the static and dynamic balance performance of students with normal hearing and with sensorineural hearing loss. Methods A cross-sectional study assessing 96 students, 48 with normal hearing and 48 with sensorineural hearing loss of both sexes, aged 7 and 18 years. To evaluate static balance, Romberg, Romberg-Barré and Fournier tests were used; and for the dynamic balance, we applied the Unterberger test. Results Hearing loss students showed more changes in static ...

  8. Acute Changes in Creatine Kinase Serum Levels in Adults Submitted a Static Stretching and Maximal Strength Test

    Directory of Open Access Journals (Sweden)

    M.G. Bara Filho

    2008-01-01

    Full Text Available Strength and flexibility are common components of a training program and their maximal values are obtained through specific tests. However, little information about the damage effect of these training procedures in a skeletal muscle is known. Objective: To verify a serum CK changes 24 h after a sub maximal stretching routine and after the static flexibility and maximal strength tests. Methods: the sample was composed by 14 subjects (man and women, 28 ± 6 yr. physical education students. The volunteers were divided in a control group (CG and experimental group (EG that was submitted in a stretching routine (EG-ST, in a maximal flexibility static test (EG-FLEX and in 1-RM test (EG-1-RM, with one week interval among tests. The anthropometrics characteristics were obtained by digital scale with stadiometer (Filizola, São Paulo, Brasil, 2002. The blood samples were obtained using the IFCC method with reference values 26-155 U/L. The De Lorme and Watkins technique was used to access maximal maximal strength through bench press and leg press. The maximal flexibility test consisted in three 20 seconds sets until the point of maximal discomfort. The stretching was done in normal movement amplitude during 6 secons. Results: The basal and post 24 h CK values in CG and EG (ST; Flex and 1 RM were respectively 195,0 ± 129,5 vs. 202,1 ± 124,2; 213,3 ± 133,2 vs. 174,7 ± 115,8; 213,3 ± 133,2 vs. 226,6 ± 126,7 e 213,3 ± 133,2 vs. 275,9 ± 157,2. It was only observed a significant difference (p = 0,02 in the pre and post values inGE-1RM. Conclusion: only maximal strength dynamic exercise was capable to cause skeletal muscle damage.

  9. VLE measurements using a static cell vapor phase manual sampling method accompanied with an empirical data consistency test

    International Nuclear Information System (INIS)

    Freitag, Joerg; Kosuge, Hitoshi; Schmelzer, Juergen P.; Kato, Satoru

    2015-01-01

    Highlights: • We use a new, simple static cell vapor phase manual sampling method (SCVMS) for VLE (x, y, T) measurement. • The method is applied to non-azeotropic, asymmetric and two-liquid phase forming azeotropic binaries. • The method is approved by a data consistency test, i.e., a plot of the polarity exclusion factor vs. pressure. • The consistency test reveals that with the new SCVMS method accurate VLE near ambient temperature can be measured. • Moreover, the consistency test approves that the effect of air in the SCVMS system is negligible. - Abstract: A new static cell vapor phase manual sampling (SCVMS) method is used for the simple measurement of constant temperature x, y (vapor + liquid) equilibria (VLE). The method was applied to the VLE measurements of the (methanol + water) binary at T/K = (283.2, 298.2, 308.2 and 322.9), asymmetric (acetone + 1-butanol) binary at T/K = (283.2, 295.2, 308.2 and 324.2) and two-liquid phase forming azeotropic (water + 1-butanol) binary at T/K = (283.2 and 298.2). The accuracy of the experimental data was approved by a data consistency test, that is, an empirical plot of the polarity exclusion factor, β, vs. the system pressure, P. The SCVMS data are accurate, because the VLE data converge to the same lnβ vs. lnP straight line determined from conventional distillation-still method and a headspace gas chromatography method

  10. Static Loads Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides the capability to perform large-scale structural loads testing on spacecraft and other structures. Results from these tests can be used to verify...

  11. Quasi-static characterisation and impact testing of auxetic foam for sports safety applications

    International Nuclear Information System (INIS)

    Duncan, Olly; Alderson, Andrew; Foster, Leon; Senior, Terry; Allen, Tom

    2016-01-01

    This study compared low strain rate material properties and impact force attenuation of auxetic foam and the conventional open-cell polyurethane counterpart. This furthers our knowledge with regards to how best to apply these highly conformable and breathable auxetic foams to protective sports equipment. Cubes of auxetic foam measuring 150 × 150 × 150 mm were fabricated using a thermo–mechanical conversion process. Quasi-static compression confirmed the converted foam to be auxetic, prior to being sliced into 20 mm thick cuboid samples for further testing. Density, Poisson’s ratio and the stress–strain curve were all found to be dependent on the position of each cuboid from within the cube. Impact tests with a hemispherical drop hammer were performed for energies up to 6 J, on foams covered with a polypropylene sheet between 1 and 2 mm thick. Auxetic samples reduced peak force by ∼10 times in comparison to the conventional foam. This work has shown further potential for auxetic foam to be applied to protective equipment, while identifying that improved fabrication methods are required. (paper)

  12. Calibration of a pitot-static rake

    Science.gov (United States)

    Stump, H. P.

    1977-01-01

    A five-element pitot-static rake was tested to confirm its accuracy and determine its suitability for use at Langley during low-speed tunnel calibration primarily at full-scale tunnel. The rake was tested at one airspeed of 74 miles per hour (33 meters per second) and at pitch and yaw angles of 0 to + or - 20 degrees in 4 deg increments.

  13. Static frictional resistance with the slide low-friction elastomeric ligature system.

    Science.gov (United States)

    Jones, Steven P; Ben Bihi, Saida

    2009-11-01

    This ex-vivo study compared the static frictional resistance of a low-friction ligation system against a conventional elastomeric module, and studied the effect of storage in a simulated oral environment on the static frictional resistance of both ligation systems. Eighty stainless steel brackets were tested by sliding along straight lengths of 0.018 inch round and 0.019 x 0.025 inch rectangular stainless steel wires ligated with either conventional elastomerics or the Slide system (Leone, Florence, Italy). During the tests the brackets and wires were lubricated with artificial saliva. A specially constructed jig assembly was used to hold the bracket and archwire securely. The jig was clamped in an Instron universal load testing machine. Crosshead speed was controlled via a microcomputer connected to the Instron machine. The static frictional forces at 0 degree bracket/wire angulation were measured for both systems, fresh from the pack and after storage in artificial saliva at 37 degrees C for 24 hours. The results of this investigation demonstrated that the Slide ligatures produced significantly lower static frictional resistance than conventional elastomeric modules in the fresh condition and after 24 hours of storage in a simulated oral environment (p static frictional resistance of conventional elastomeric modules and the Slide system (p = 0.525). The claim by the manufacturer that the Slide system produces lower frictional resistance than conventional elastomeric modules is upheld.

  14. Patellofemoral Pressure Changes After Static and Dynamic Medial Patellofemoral Ligament Reconstructions.

    Science.gov (United States)

    Rood, Akkie; Hannink, Gerjon; Lenting, Anke; Groenen, Karlijn; Koëter, Sander; Verdonschot, Nico; van Kampen, Albert

    2015-10-01

    Reconstructing the medial patellofemoral ligament (MPFL) has become a key procedure for stabilizing the patella. Different techniques to reconstruct the MPFL have been described: static techniques in which the graft is fixed rigidly to the bone or dynamic techniques with soft tissue fixation. Static MPFL reconstruction is most commonly used. However, dynamic reconstruction deforms more easily and presumably functions more like the native MPFL. The aim of the study was to evaluate the effect of the different MPFL fixation techniques on patellofemoral pressures compared with the native situation. The hypothesis was that dynamic reconstruction would result in patellofemoral pressures closer to those generated in an intact knee. Controlled laboratory study. Seven fresh-frozen knee specimens were tested in an in vitro knee joint loading apparatus. Tekscan pressure-sensitive films fixed to the retropatellar cartilage measured mean patellofemoral and peak pressures, contact area, and location of the center of force (COF) at fixed flexion angles from 0° to 110°. Four different conditions were tested: intact, dynamic, partial dynamic, and static MPFL reconstruction. Data were analyzed using linear mixed models. Static MPFL reconstruction resulted in higher peak and mean pressures from 60° to 110° of flexion (P .05). The COF in the static reconstruction group moved more medially on the patella from 50° to 110° of flexion compared with the other conditions. The contact area showed no significant differences between the test conditions. After static MPFL reconstruction, the patellofemoral pressures in flexion angles from 60° to 110° were 3 to 5 times higher than those in the intact situation. The pressures after dynamic MPFL reconstruction were similar as compared with those in the intact situation, and therefore, dynamic MPFL reconstruction could be a safer option than static reconstruction for stabilizing the patella. This study showed that static MPFL reconstruction

  15. Non-local means filter for trim statics

    KAUST Repository

    Huang, Yunsong

    2014-08-05

    Structures will be mispositioned across prestack migration gathers in the presence of inaccuracies in the velocity model. Stacking these misaligned gathers runs the risk of destroying important structures in the stacked migration image. To mitigate this problem, we propose a trim statics inspired by the non-local means algorithm originally developed for image denoising. This method differs from the conventional one in two fundamental respects. First, the trim statics are computed by comparing image patches instead of individual image traces. Second, no global pilot trace is needed because only two migration images at a time participate in trim statics and are stacked into one image. A multitude of migration images are stacked recursively in this two-to-one fashion. Tests with a Gulf of Mexico dataset show a noticeable improvement in the feature coherency of the stacked migration image.

  16. Pre-exposure to moving form enhances static form sensitivity.

    Directory of Open Access Journals (Sweden)

    Thomas S A Wallis

    Full Text Available BACKGROUND: Motion-defined form can seem to persist briefly after motion ceases, before seeming to gradually disappear into the background. Here we investigate if this subjective persistence reflects a signal capable of improving objective measures of sensitivity to static form. METHODOLOGY/PRINCIPAL FINDINGS: We presented a sinusoidal modulation of luminance, masked by a background noise pattern. The sinusoidal luminance modulation was usually subjectively invisible when static, but visible when moving. We found that drifting then stopping the waveform resulted in a transient subjective persistence of the waveform in the static display. Observers' objective sensitivity to the position of the static waveform was also improved after viewing moving waveforms, compared to viewing static waveforms for a matched duration. This facilitation did not occur simply because movement provided more perspectives of the waveform, since performance following pre-exposure to scrambled animations did not match that following pre-exposure to smooth motion. Observers did not simply remember waveform positions at motion offset, since removing the waveform before testing reduced performance. CONCLUSIONS/SIGNIFICANCE: Motion processing therefore interacts with subsequent static visual inputs in a way that can improve performance in objective sensitivity measures. We suggest that the brief subjective persistence of motion-defined forms that can occur after motion offsets is a consequence of the decay of a static form signal that has been transiently enhanced by motion processing.

  17. The relationship between gait parameters and static and dynamic balance in the elderly

    Directory of Open Access Journals (Sweden)

    Razieh Tabe

    2015-02-01

    Full Text Available Background: The physiological changes and muscle problems can lead to balance disorder and increased risk of falling among the elderly. Therefore, it is necessary to evaluate the factors associated with balance in the elderly, to increase their awareness of the falling risks and to provide them with appropriate assistive devices.. Hence, this study was carried out to investigate the relationship between some gait parameters and static and dynamic balance in the elderly. Methods: In this quasi-experimental study, 44 men and women in two groups (22 per group participated as the study sample. The measured values included step length, stride length, step width, rotating angle of toes, and static and dynamic balance. The static balance was measured with Romberg test and dynamic balance with TUGTU test. Data were analysed by SPSS-15 software using t-test and Pearson correlation coefficient. Results: There was a significant relationship between step length and stride length with static and dynamic balance and between step width and dynamic balance (p0/05. But no significant relationship was reported between step width and static balance and between rotating angle of toes with static and dynamic balance among the elderly. Conclusions: the elderly balance can be improved by decreasing the step length and increasing the stride length, thereby reducing the possibility of their falling.

  18. The Impact of One Heat Treated Contact Element on the Coefficient of Static Friction

    Directory of Open Access Journals (Sweden)

    P. Todorović, , , , , ,

    2013-12-01

    Full Text Available The subject of the paper includes theoretical considerations, the conducting of experimental tests, and the analysis of exposed test results related to determination of the coefficient of static friction of previously heat-treated contact pairs. One contact element is previously, before the procedure of determining the coefficient of static friction, heated at temperatures in the range of ambient temperature to 280°C and then cooled down to ambient temperature. The results of experimental tests of five different materials show that depending on the heat treatment of one contact element, there is a significant decrease in the coefficient of static friction. The authors of the paper consider that the reasons for the decreasing coefficient of static friction are related to oxide formation and changes in the surface layer of the contact element which is previously heat-treated.

  19. Duration Dependent Effect of Static Stretching on Quadriceps and Hamstring Muscle Force

    Directory of Open Access Journals (Sweden)

    Leyla Alizadeh Ebadi

    2018-03-01

    Full Text Available The aim of this study was to determine the acute effect of static stretching on hamstring and quadriceps muscles’ isokinetic strength when applied for various durations to elite athletes, to investigate the effect of different static stretching durations on isokinetic strength, and finally to determine the optimal stretching duration. Fifteen elite male athletes from two different sport branches (10 football and five basketball participated in this study. Experimental protocol was designed as 17 repetitive static stretching exercises for hamstring and quadriceps muscle groups according to the indicated experimental protocols; ((A 5 min jogging; (B 5 min jogging followed by 15 s static stretching; (C 5 min jogging followed by 30 s static stretching; (D 5 min jogging, followed by static stretching for 45 s. Immediately after each protocol, an isokinetic strength test consisting of five repetitions at 60°/s speed and 20 repetitions at 180°/s speed was recorded for the right leg by the Isomed 2000 device. Friedman variance analysis test was employed for data analysis. According to the analyzes, it was observed that 5 min jogging and 15 s stretching exercises increased the isokinetic strength, whereas 30 and 45 s stretching exercises caused a decrease.

  20. Predicting vertebral bone strength by vertebral static histomorphometry

    DEFF Research Database (Denmark)

    Thomsen, Jesper Skovhus; Ebbesen, Ebbe Nils; Mosekilde, Lis

    2002-01-01

    of the entire vertebral bodies (L-2) were used for histomorphometry. The other iliac crest biopsies and the L-3 were destructively tested by compression. High correlation was found between BV/TV or Tb.Sp and vertebral bone strength (absolute value of r = 0.86 in both cases). Addition of Tb.Th significantly....... No gender-related differences were found in any of the relationships. Neither static histomorphometry nor biomechanical testing of iliac crest bone biopsies is a good predictor of vertebral bone strength.......The study investigates the relationship between static histomorphometry and bone strength of human lumbar vertebral bone. The ability of vertebral histomorphometry to predict vertebral bone strength was compared with that of vertebral densitometry, and also with histomorphometry and bone strength...

  1. Effects of Static Stretching and Playing Soccer on Knee Laxity.

    Science.gov (United States)

    Baumgart, Christian; Gokeler, Alli; Donath, Lars; Hoppe, Matthias W; Freiwald, Jürgen

    2015-11-01

    This study investigated exercise-induced effects of static stretching and playing soccer on anterior tibial translation (ATT) of the knee joint. Randomized controlled trial. University biomechanics laboratory. Thirty-one athletes were randomly assigned into a stretching (26.9 ± 6.2 years, 1.77 ± 0.09 m, 67.9 ± 10.7 kg) and a control group (27.9 ± 7.4 years, 1.75 ± 0.08 m, 72.0 ± 14.9 kg). Thirty-one amateur soccer players in an additional soccer group (25.1 ± 5.6 years, 1.74 ± 0.10 m, 71.8 ± 14.8 kg). All participants had no history of knee injury requiring surgery and any previous knee ligament or cartilage injury. The stretching group performed 4 different static stretching exercises with a duration of 2 × 20 seconds interspersed with breaks of 10 seconds. The soccer group completed a 90-minute soccer-specific training program. The control group did not perform any physical activity for approximately 30 minutes. Anterior tibial translation was measured with the KT-1000 knee arthrometer at forces of 67 N, 89 N, and maximal manual force (Max) before and after the intervention. There was a significant increase in ATT after static stretching and playing soccer at all applied forces. Maximal manual testing revealed a mean increase of ATT after static stretching of 2.1 ± 1.6 mm (P soccer of 1.0 ± 1.5 mm (P = 0.001). The ATT increase after static stretching at 67 and 89 N is significantly higher than in controls. At maximum manual testing, significant differences were evident between all groups. Static stretching and playing soccer increase ATT and may consequently influence mechanical factors of the anterior cruciate ligament. The ATT increase after static stretching was greater than after playing soccer. The observed increase in ATT after static stretching and playing soccer may be associated with changes in kinesthetic perception and sensorimotor control, activation of muscles, joint stability, overall performance, and higher injury risk.

  2. Static Behaviour of Bucket Foundations

    DEFF Research Database (Denmark)

    Larsen, Kim André

    One new foundation concept in relation to offshore wind turbines is bucket foundations. The concept is known from the oil and gas industry, though the load conditions here are significantly different. The bucket foundation can be used as monopod or e.g. tripod foundations for offshore wind turbines....... The monopod concept is investigated in this thesis, regarding the static behaviour from loads relevant to offshore wind turbines. The main issue in this concept is the rotational stiffness of the foundation and the combined capacity dominated by moments. The vertical bearing capacity of bucket foundations...... theory is proposed. The proposed expression applies to plane strain as well as axis-symmetric stress conditions for foundations with smooth or rough bases. A thorough experimental investigation of the static behaviour of bucket foundations subjected to combined loading is carried out. Laboratory tests...

  3. Static and dynamic strain energy release rates in toughened thermosetting composite laminates

    Science.gov (United States)

    Cairns, Douglas S.

    1992-01-01

    In this work, the static and dynamic fracture properties of several thermosetting resin based composite laminates are presented. Two classes of materials are explored. These are homogeneous, thermosetting resins and toughened, multi-phase, thermosetting resin systems. Multi-phase resin materials have shown enhancement over homogenous materials with respect to damage resistance. The development of new dynamic tests are presented for composite laminates based on Width Tapered Double Cantilevered Beam (WTDCB) for Mode 1 fracture and the End Notched Flexure (ENF) specimen. The WTDCB sample was loaded via a low inertia, pneumatic cylinder to produce rapid cross-head displacements. A high rate, piezo-electric load cell and an accelerometer were mounted on the specimen. A digital oscilloscope was used for data acquisition. Typical static and dynamic load versus displacement plots are presented. The ENF specimen was impacted in three point bending with an instrumented impact tower. Fracture initiation and propagation energies under static and dynamic conditions were determined analytically and experimentally. The test results for Mode 1 fracture are relatively insensitive to strain rate effects for the laminates tested in this study. The test results from Mode 2 fracture indicate that the toughened systems provide superior fracture initiation and higher resistance to propagation under dynamic conditions. While the static fracture properties of the homogeneous systems may be relatively high, the apparent Mode 2 dynamic critical strain energy release rate drops significantly. The results indicate that static Mode 2 fracture testing is inadequate for determining the fracture performance of composite structures subjected to conditions such as low velocity impact. A good correlation between the basic Mode 2 dynamic fracture properties and the performance is a combined material/structural Compression After Impact (CAI) test is found. These results underscore the importance of

  4. From Static Output Feedback to Structured Robust Static Output Feedback: A Survey

    OpenAIRE

    Sadabadi , Mahdieh ,; Peaucelle , Dimitri

    2016-01-01

    This paper reviews the vast literature on static output feedback design for linear time-invariant systems including classical results and recent developments. In particular, we focus on static output feedback synthesis with performance specifications, structured static output feedback, and robustness. The paper provides a comprehensive review on existing design approaches including iterative linear matrix inequalities heuristics, linear matrix inequalities with rank constraints, methods with ...

  5. Performance of Geosynthetic-Reinforced Soils Under Static and Cyclic Loading

    Directory of Open Access Journals (Sweden)

    M. Touahmia

    2017-04-01

    Full Text Available This paper investigates and discusses the composite behavior of geosynthetic reinforced soil mass. It presents the results of a series of large-scale laboratory tests supported by analytical methods to examine the performance of geogrid reinforcement subjected to static and cyclic pullout loading. The testing equipment and procedures used for this investigation are outlined. The results show that geosynthetic reinforcement can mobilize great resistance to static pulling load under high confining pressures. The reinforcement exhibits gradual deformation under cyclic loading showing no sign of imminent pullout failure for all levels of applied loads. In general, the results demonstrate that geosynthetic can be used in situations where loads are non-static, although care will be required in ensuring that appropriate factors of safety are applied to control the resulting deformation. A simplified analytical model for calculating the pulling capacity of geosynthetic reinforcement is proposed.

  6. Static and dynamic balance of children and adolescents with sensorineural hearing loss

    OpenAIRE

    Melo, Renato de Souza; Marinho, Sônia Elvira dos Santos; Freire, Maryelly Evelly Araújo; Souza, Robson Arruda; Damasceno, Hélio Anderson Melo; Raposo, Maria Cristina Falcão

    2017-01-01

    ABSTRACT Objective To assess the static and dynamic balance performance of students with normal hearing and with sensorineural hearing loss. Methods A cross-sectional study assessing 96 students, 48 with normal hearing and 48 with sensorineural hearing loss of both sexes, aged 7 and 18 years. To evaluate static balance, Romberg, Romberg-Barré and Fournier tests were used; and for the dynamic balance, we applied the Unterberger test. Results Hearing loss students showed more changes in s...

  7. EFFECTS OF DYNAMIC AND STATIC STRETCHING WITHIN GENERAL AND ACTIVITY SPECIFIC WARM-UP PROTOCOLS

    Directory of Open Access Journals (Sweden)

    Michael Samson

    2012-06-01

    Full Text Available The purpose of the study was to determine the effects of static and dynamic stretching protocols within general and activity specific warm-ups. Nine male and ten female subjects were tested under four warm-up conditions including a 1 general aerobic warm-up with static stretching, 2 general aerobic warm-up with dynamic stretching, 3 general and specific warm-up with static stretching and 4 general and specific warm-up with dynamic stretching. Following all conditions, subjects were tested for movement time (kicking movement of leg over 0.5 m distance, countermovement jump height, sit and reach flexibility and 6 repetitions of 20 metre sprints. Results indicated that when a sport specific warm-up was included, there was an 0.94% improvement (p = 0.0013 in 20 meter sprint time with both the dynamic and static stretch groups. No such difference in sprint performance between dynamic and static stretch groups existed in the absence of the sport specific warm-up. The static stretch condition increased sit and reach range of motion (ROM by 2.8% more (p = 0.0083 than the dynamic condition. These results would support the use of static stretching within an activity specific warm-up to ensure maximal ROM along with an enhancement in sprint performance

  8. The role of visual representation in physics learning: dynamic versus static visualization

    Science.gov (United States)

    Suyatna, Agus; Anggraini, Dian; Agustina, Dina; Widyastuti, Dini

    2017-11-01

    This study aims to examine the role of visual representation in physics learning and to compare the learning outcomes of using dynamic and static visualization media. The study was conducted using quasi-experiment with Pretest-Posttest Control Group Design. The samples of this research are students of six classes at State Senior High School in Lampung Province. The experimental class received a learning using dynamic visualization and control class using static visualization media. Both classes are given pre-test and post-test with the same instruments. Data were tested with N-gain analysis, normality test, homogeneity test and mean difference test. The results showed that there was a significant increase of mean (N-Gain) learning outcomes (p physical phenomena and requires long-term observation.

  9. Static and dynamic biomechanical properties of the regenerating rabbit Achilles tendon.

    Science.gov (United States)

    Nagasawa, Koji; Noguchi, Masahiko; Ikoma, Kazuya; Kubo, Toshikazu

    2008-07-01

    Since tendons show viscoelastic behavior, dynamic viscoelastic properties should be assessed in addition to static biomechanical properties. We evaluated differences between static and dynamic biomechanical properties of the regenerating rabbit Achilles tendon following tenotomy. At 3, 6, or 12 weeks after right Achilles tenotomy, the right (regenerating) and left (control) tendons were collected with the calcaneus from 49 rabbits. A unidirectional failure test and a dynamic viscoelastic test were conducted. Tensile strength and Young's modulus (static biomechanical properties) in the regenerating group at Week 6 were significantly greater than at Week 3, while at Week 12, these were significantly greater than at Week 6. However, even at Week 12, both parameters were less than in the control group. The value of tan delta represents dynamic viscoelasticity, a smaller tan delta indicates greater elasticity. tan delta for the regenerating group was significantly greater than for the control group at Week 3, but regenerating and control groups did not significantly differ at Week 6. No marked change was seen from Weeks 6 to 12 in the regenerating group, and no significant difference in tan delta was evident between the regenerating and control groups at Week 12. Dynamic biomechanical properties of regenerating rabbit Achilles tendons may improve more rapidly than static biomechanical properties. Ability to tolerate dynamic movement in the healing Achilles tendon may improve more rapidly than ability to withstand static stresses.

  10. Comparison of static friction with self-ligating, modified slot design and conventional brackets

    Directory of Open Access Journals (Sweden)

    Raquel Morais Castro

    2013-07-01

    Full Text Available OBJECTIVE: To compare the static frictional forces generated at the bracket/wire interface of stainless steel brackets with different geometries and angulations, combined with orthodontic wires of different diameters. MATERIAL AND METHODS: The frictional forces were evaluated with three different types of metal brackets: a passive self-ligating (SmartClipTM, 3M/Unitek, Monrovia, USA, with a modified slot design (Mini Uni TwinTM, 3M/Unitek, Monrovia, USA and conventional (Kirium, Abzil, São José do Rio Preto, Brazil. The samples were mounted in a testing device with three different angulations and tested with 0.014" and 0.018" stainless steel wires (American Orthodontics, Sheboygan, USA. The static frictional force was measured using a universal testing machine (DL 500, EMIC®, São José dos Pinhais, Brazil with a crosshead speed of 1 mm/min. Statistical analysis was performed by two-way ANOVA followed by Bonferroni's post hoc test. RESULTS: There was a significant difference (p<0.05 in static friction when the three types of brackets were tested with the same wire size. The wire diameter influenced friction only when the brackets had a 10º angulation (p<0.05. The angulation influenced friction (p<0.05 when the brackets were associated with a 0.018" wire. CONCLUSION: Brackets with a modified slot design showed intermediate static frictional force values between the conventional and self-ligating brackets tested.

  11. Utility of the Static-99 and Static-99R With Latino Sex Offenders.

    Science.gov (United States)

    Leguízamo, Alejandro; Lee, Seung C; Jeglic, Elizabeth L; Calkins, Cynthia

    2017-12-01

    The predictive validity of the Static-99 measures with ethnic minorities in the United States has only recently been assessed with mixed results. We assessed the predictive validity of the Static-99 and Static-99R with a sample of Latino sex offenders ( N = 483) as well as with two subsamples (U.S.-born, including Puerto Rico, and non-U.S.-born). The overall sexual recidivism rate was very low (1.9%). Both the Static-99 measures were able to predict sexual recidivism for offenders born in the United States and Puerto Rico, but neither was effective in doing so for other Latino immigrants. Calibration analyses ( N = 303) of the Static-99R were consistent with the literature and provided support for the potential use of the measure with Latinos born in the United States and Puerto Rico. These findings and their implications are discussed as they pertain to the assessment of Latino sex offenders.

  12. Static analysis of a piping system with elbows

    International Nuclear Information System (INIS)

    Bryan, B.J.

    1994-01-01

    Vibration tests of elbows to failure were performed in Japan in the early 1970s. The piping system included two elbows and an eccentric mass. Tests were run both pressurized and unpressurized. This report documents a static analysis of the piping system in which the elbows are subjected to out of plane bending. The effects of internal pressure and material plasticity are investigated

  13. Static security-based available transfer capability using adaptive neuro fuzzy inference system

    Energy Technology Data Exchange (ETDEWEB)

    Venkaiah, C.; Vinod Kumar, D.M.

    2010-07-01

    In a deregulated power system, power transactions between a seller and a buyer can only be scheduled when there is sufficient available transfer capability (ATC). Internet-based, open access same-time information systems (OASIS) provide market participants with ATC information that is continuously updated in real time. Static security-based ATC can be computed for the base case system as well as for the critical line outages of the system. Since critical line outages are based on static security analysis, the computation of static security based ATC using conventional methods is both tedious and time consuming. In this study, static security-based ATC was computed for real-time applications using 3 artificial intelligent methods notably the back propagation algorithm (BPA), the radial basis function (RBF) neural network, and the adaptive neuro fuzzy inference system (ANFIS). An IEEE 24-bus reliability test system (RTS) and 75-bus practical system were used to test these 3 different intelligent methods. The results were compared with the conventional full alternating current (AC) load flow method for different transactions.

  14. Static security-based available transfer capability using adaptive neuro fuzzy inference system

    International Nuclear Information System (INIS)

    Venkaiah, C.; Vinod Kumar, D.M.

    2010-01-01

    In a deregulated power system, power transactions between a seller and a buyer can only be scheduled when there is sufficient available transfer capability (ATC). Internet-based, open access same-time information systems (OASIS) provide market participants with ATC information that is continuously updated in real time. Static security-based ATC can be computed for the base case system as well as for the critical line outages of the system. Since critical line outages are based on static security analysis, the computation of static security based ATC using conventional methods is both tedious and time consuming. In this study, static security-based ATC was computed for real-time applications using 3 artificial intelligent methods notably the back propagation algorithm (BPA), the radial basis function (RBF) neural network, and the adaptive neuro fuzzy inference system (ANFIS). An IEEE 24-bus reliability test system (RTS) and 75-bus practical system were used to test these 3 different intelligent methods. The results were compared with the conventional full alternating current (AC) load flow method for different transactions.

  15. SHORT DURATIONS OF STATIC STRETCHING WHEN COMBINED WITH DYNAMIC STRETCHING DO NOT IMPAIR REPEATED SPRINTS AND AGILITY

    Directory of Open Access Journals (Sweden)

    Del P. Wong

    2011-06-01

    Full Text Available This study aimed to compare the effect of different static stretching durations followed by dynamic stretching on repeated sprint ability (RSA and change of direction (COD. Twenty-five participants performed the RSA and COD tests in a randomized order. After a 5 min aerobic warm up, participants performed one of the three static stretching protocols of 30 s, 60 s or 90 s total duration (3 stretches x 10 s, 20 s or 30 s. Three dynamic stretching exercises of 30 s duration were then performed (90 s total. Sit-and-reach flexibility tests were conducted before the aerobic warm up, after the combined static and dynamic stretching, and post- RSA/COD test. The duration of static stretching had a positive effect on flexibility with 36.3% and 85.6% greater sit-and-reach scores with the 60 s and 90 s static stretching conditions respectively than with the 30 s condition (p < 0.001. However there were no significant differences in RSA and COD performance between the 3 stretching conditions. The lack of change in RSA and COD might be attributed to a counterbalancing of static and dynamic stretching effects. Furthermore, the short duration (< 90 s static stretching may not have provided sufficient stimulus to elicit performance impairments

  16. Short Durations of Static Stretching when Combined with Dynamic Stretching do not Impair Repeated Sprints and Agility.

    Science.gov (United States)

    Wong, Del P; Chaouachi, Anis; Lau, Patrick W C; Behm, David G

    2011-01-01

    This study aimed to compare the effect of different static stretching durations followed by dynamic stretching on repeated sprint ability (RSA) and change of direction (COD). Twenty-five participants performed the RSA and COD tests in a randomized order. After a 5 min aerobic warm up, participants performed one of the three static stretching protocols of 30 s, 60 s or 90 s total duration (3 stretches x 10 s, 20 s or 30 s). Three dynamic stretching exercises of 30 s duration were then performed (90 s total). Sit-and-reach flexibility tests were conducted before the aerobic warm up, after the combined static and dynamic stretching, and post- RSA/COD test. The duration of static stretching had a positive effect on flexibility with 36.3% and 85.6% greater sit-and-reach scores with the 60 s and 90 s static stretching conditions respectively than with the 30 s condition (p ≤ 0.001). However there were no significant differences in RSA and COD performance between the 3 stretching conditions. The lack of change in RSA and COD might be attributed to a counterbalancing of static and dynamic stretching effects. Furthermore, the short duration (≤ 90 s) static stretching may not have provided sufficient stimulus to elicit performance impairments. Key pointsThe duration of combined static and dynamic stretching had a positive effect on flexibility with 36.3% and 85.6% greater sit and reach scores with the 60 s and 90 s static stretching conditions respectively than with the 30 s condition (p ≤ 0.001).No significant differences in RSA and COD between the 3 stretching conditions.The lack of change in RSA and COD might be attributed to a counterbalancing of static and dynamic stretching effects.The short duration (≤ 90 s) static stretching may not have provided sufficient stimulus to elicit performance impairments.

  17. Short Durations of Static Stretching when Combined with Dynamic Stretching do not Impair Repeated Sprints and Agility

    Science.gov (United States)

    Wong, Del P.; Chaouachi, Anis; Lau, Patrick W.C.; Behm, David G.

    2011-01-01

    This study aimed to compare the effect of different static stretching durations followed by dynamic stretching on repeated sprint ability (RSA) and change of direction (COD). Twenty-five participants performed the RSA and COD tests in a randomized order. After a 5 min aerobic warm up, participants performed one of the three static stretching protocols of 30 s, 60 s or 90 s total duration (3 stretches x 10 s, 20 s or 30 s). Three dynamic stretching exercises of 30 s duration were then performed (90 s total). Sit-and-reach flexibility tests were conducted before the aerobic warm up, after the combined static and dynamic stretching, and post- RSA/COD test. The duration of static stretching had a positive effect on flexibility with 36.3% and 85.6% greater sit-and-reach scores with the 60 s and 90 s static stretching conditions respectively than with the 30 s condition (p ≤ 0.001). However there were no significant differences in RSA and COD performance between the 3 stretching conditions. The lack of change in RSA and COD might be attributed to a counterbalancing of static and dynamic stretching effects. Furthermore, the short duration (≤ 90 s) static stretching may not have provided sufficient stimulus to elicit performance impairments. Key points The duration of combined static and dynamic stretching had a positive effect on flexibility with 36.3% and 85.6% greater sit and reach scores with the 60 s and 90 s static stretching conditions respectively than with the 30 s condition (p ≤ 0.001). No significant differences in RSA and COD between the 3 stretching conditions. The lack of change in RSA and COD might be attributed to a counterbalancing of static and dynamic stretching effects. The short duration (≤ 90 s) static stretching may not have provided sufficient stimulus to elicit performance impairments. PMID:24149890

  18. Method of rheological characterization of polymer materials by identification of the prony viscoelastic model according to data of static and dynamic accelerated tests

    Science.gov (United States)

    Shil'ko, S. V.; Gavrilenko, S. L.; Panin, S. V.; Alexenko, V. O.

    2017-12-01

    A method for determining rheological parameters of the Prony model describing the process of viscoelastic deformation of a material was developed based on the results of dynamic mechanical analysis. For the approbation of the method, static (uniaxial tension) and dynamic (three-point bending) mechanical tests of polymer composites were carried out. Based on the analytical dependence of the storage modulus on the parameters of the Prony model, the parameters of the shear function are determined. The results of the static and dynamic analysis are in good agreement. The proposed technique allows us to accelerate the determination of rheological parameters of polymer materials and recommend it to the calculation of the stress-strain state of structural elements and friction joints during their long operation at elevated temperature.

  19. Energy based study of quasi-static delamination as a low cycle fatigue process

    NARCIS (Netherlands)

    Amaral, L.; Yao, L.; Alderliesten, R.C.; Benedictus, R.

    2015-01-01

    This work proposes to treat quasi-static mode I delamination growth of CFRP as a low-cycle fatigue process. To this end, mode I quasi-static and fatigue delamination tests were performed. An average physical Strain Energy Release Rate (SERR), derived from an energy balance, is used to characterize

  20. Three-way flexible cantilever probes for static contact

    International Nuclear Information System (INIS)

    Wang, Fei; Petersen, Dirch H; Hansen, Christian; Mortensen, Dennis; Friis, Lars; Hansen, Ole; Jensen, Helle V

    2011-01-01

    In micro four-point probe measurements, three-way flexible L-shaped cantilever probes show significant advantages over conventional straight cantilever probes. The L-shaped cantilever allows static contact to the sample surface which reduces the frictional wear of the cantilever tips. We analyze the geometrical design space that must be fulfilled for the cantilevers to obtain static contact with the test sample. The design space relates the spring constant tensor of the cantilevers to the minimal value of the static tip-to-sample friction coefficient. Using an approximate model, we provide the analytical calculation of the compliance matrix of the L-shaped cantilever. Compared to results derived from finite element model simulations, the theoretical model provides a good qualitative analysis while deviations for the absolute values are seen. From a statistical analysis, the deviation is small for cantilevers with low effective spring constants, while the deviation is significant for large spring constants where the quasi one-dimensional approximation is no longer valid

  1. Static electromagnetic frequency changers

    CERN Document Server

    Rozhanskii, L L

    1963-01-01

    Static Electromagnetic Frequency Changers is about the theory, design, construction, and applications of static electromagnetic frequency changers, devices that used for multiplication or division of alternating current frequency. It is originally published in the Russian language. This book is organized into five chapters. The first three chapters introduce the readers to the principles of operation, the construction, and the potential applications of static electromagnetic frequency changers and to the principles of their design. The two concluding chapters use some hitherto unpublished work

  2. Influence of acute static stretching on the behavior of maximum muscle strength

    Directory of Open Access Journals (Sweden)

    Carmen Lúcia Borges Bastos

    2014-06-01

    Full Text Available The aim of this study was to compare the influence of acute static stretching on maximal muscle strength (1RM. The non-probabilistic sample consisted of 30 subjects split into two groups: static stretching (SS= 15 and without stretching group (WS= 15. Muscle strength evaluation (1RM was conducted with a Dynamometer model 32527pp400 Pound push / pull devices coupled in knee extension (KE and bench press (BP. The Wilcoxon test for intragroup comparisons and the Kruskal-Wallis test for comparisons between groups (p< 0.05 were selected. There were no significant differences (p> 0.05 between the SS and WS in exercise KE and BP. Therefore, it can be concluded that there was no reduction in the performance of 1RM performing the exercises KE and BP when preceded by static stretching.

  3. Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios

    Science.gov (United States)

    Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin

    2015-01-01

    AIM: To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. METHODS: Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. RESULTS: The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P hamstring muscle strength at both the 60°/s and 180°/s test speeds (P 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension both in the static stretching or the control intervention (P > 0.05). CONCLUSION: According to our results, static stretching routine does not influence functional H/Q ratio. Athletes can confidently perform static stretching during their warm-up routines. PMID:26495249

  4. Results from the First Two Flights of the Static Computer Memory Integrity Testing Experiment

    Science.gov (United States)

    Hancock, Thomas M., III

    1999-01-01

    This paper details the scientific objectives, experiment design, data collection method, and post flight analysis following the first two flights of the Static Computer Memory Integrity Testing (SCMIT) experiment. SCMIT is designed to detect soft-event upsets in passive magnetic memory. A soft-event upset is a change in the logic state of active or passive forms of magnetic memory, commonly referred to as a "Bitflip". In its mildest form a soft-event upset can cause software exceptions, unexpected events, start spacecraft safeing (ending data collection) or corrupted fault protection and error recovery capabilities. In it's most severe form loss of mission or spacecraft can occur. Analysis after the first flight (in 1991 during STS-40) identified possible soft-event upsets to 25% of the experiment detectors. Post flight analysis after the second flight (in 1997 on STS-87) failed to find any evidence of soft-event upsets. The SCMIT experiment is currently scheduled for a third flight in December 1999 on STS-101.

  5. Statics of deformable solids

    CERN Document Server

    Bisplinghoff, Raymond L; Pian, Theodore HH

    2014-01-01

    Profusely illustrated exposition of fundamentals of solid mechanics and principles of mechanics, statics, and simple statically indeterminate systems. Covers strain and stress in three-dimensional solids, elementary elasticity, energy principles in solid continuum, and more. 1965 edition.

  6. Comparison of Static and Dynamic Elastic Modules of Different Strength Concretes

    Science.gov (United States)

    Uyanık, Osman; Sabbaǧ, Nevbahar

    2016-04-01

    In this study, the static and dynamic elastic (Young) modules of concrete with different strength was intended to compare. For this purpose 150mm dimensions 9 for each design cubic samples prepared and they were subjected to water cure during 28 days. After Seismic Ultrasonic P and S wave travel time measurements of samples, P and S wave velocities and taking advantage of elasticity theory the dynamic elastic modules were calculated. Concrete strength was obtained from the uniaxial compression tests in order to calculate the static elastic modules of the samples. The static elastic modulus is calculated by using the empirical relationships used in international standards. The obtained static and dynamic elastic modules have been associated. A curve was obtained from this association result that approximately similar to the stress-strain curve of obtaining at failure criterion of the sample. This study was supported with OYP05277-DR-14 Project No. by SDU and State Hydraulic Works 13th Regional/2012-01 Project No. Keywords: Concrete Strength, P and S wave Velocities, Static, Dynamic, Young Modules

  7. Dynamic brain connectivity is a better predictor of PTSD than static connectivity.

    Science.gov (United States)

    Jin, Changfeng; Jia, Hao; Lanka, Pradyumna; Rangaprakash, D; Li, Lingjiang; Liu, Tianming; Hu, Xiaoping; Deshpande, Gopikrishna

    2017-09-01

    Using resting-state functional magnetic resonance imaging, we test the hypothesis that subjects with post-traumatic stress disorder (PTSD) are characterized by reduced temporal variability of brain connectivity compared to matched healthy controls. Specifically, we test whether PTSD is characterized by elevated static connectivity, coupled with decreased temporal variability of those connections, with the latter providing greater sensitivity toward the pathology than the former. Static functional connectivity (FC; nondirectional zero-lag correlation) and static effective connectivity (EC; directional time-lagged relationships) were obtained over the entire brain using conventional models. Dynamic FC and dynamic EC were estimated by letting the conventional models to vary as a function of time. Statistical separation and discriminability of these metrics between the groups and their ability to accurately predict the diagnostic label of a novel subject were ascertained using separate support vector machine classifiers. Our findings support our hypothesis that PTSD subjects have stronger static connectivity, but reduced temporal variability of connectivity. Further, machine learning classification accuracy obtained with dynamic FC and dynamic EC was significantly higher than that obtained with static FC and static EC, respectively. Furthermore, results also indicate that the ease with which brain regions engage or disengage with other regions may be more sensitive to underlying pathology than the strength with which they are engaged. Future studies must examine whether this is true only in the case of PTSD or is a general organizing principle in the human brain. Hum Brain Mapp 38:4479-4496, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. Static Buckling Model Tests and Elasto-plastic Finite Element Analysis of a Pile in Layers with Various Thicknesses

    Science.gov (United States)

    Okajima, Kenji; Imai, Junichi; Tanaka, Tadatsugu; Iida, Toshiaki

    Damage to piles in the liquefied ground is frequently reported. Buckling by the excess vertical load could be one of the causes of the pile damage, as well as the lateral flow of the ground and the lateral load at the pile head. The buckling mechanism is described as a complicated interaction between the pile deformation by the vertical load and the earth pressure change cased by the pile deformation. In this study, series of static buckling model tests of a pile were carried out in dried sand ground with various thickness of the layer. Finite element analysis was applied to the test results to verify the effectiveness of the elasto-plastic finite element analysis combining the implicit-explicit mixed type dynamic relaxation method with the return mapping method to the pile buckling problems. The test results and the analysis indicated the possibility that the buckling load of a pile decreases greatly where the thickness of the layer increases.

  9. Static vs dynamic settlement and adhesion of diatoms to ship hull coatings.

    Science.gov (United States)

    Zargiel, Kelli A; Swain, Geoffrey W

    2014-01-01

    Many experiments utilize static immersion tests to evaluate the performance of ship hull coatings. These provide valuable data; however, they do not accurately represent the conditions both the hull and fouling organisms encounter while a ship is underway. This study investigated the effect of static and dynamic immersion on the adhesion and settlement of diatoms to one antifouling coating (BRA 640), four fouling-release coatings (Intersleek(®) 700, Intersleek(®) 900, Hempasil X3, and Dow Corning 3140) and one standard surface (Intergard(®) 240 Epoxy). Differences in community composition were observed between the static and dynamic treatments. Achnanthes longipes was present on all coatings under static immersion, but was not present under dynamic immersion. This was also found for diatoms in the genera Bacillaria and Gyrosigma. Melosira moniformis was the only diatom present under dynamic conditions, but not static conditions. Several common fouling diatom genera were present on panels regardless of treatment: Amphora, Cocconeis, Entomoneis Cylindrotheca, Licmophora, Navicula, Nitzschia, Plagiotropis, and Synedra. Biofilm adhesion, diatom abundance and diatom diversity were found to be significantly different between static and dynamic treatments; however, the difference was dependent on coating and sampling date. Several coatings (Epoxy, DC 3140 and IS 700) had significantly higher biofilm adhesion on dynamically treated panels on at least one of the four sampling dates, while all coatings had significantly higher diatom abundance on at least one sampling date. Diversity was significantly greater on static panels than dynamic panels for Epoxy, IS 700 and HX3 at least once during the sampling period. The results demonstrate how hydrodynamic stress will significantly influence the microfouling community. Dynamic immersion testing is required to fully understand how antifouling surfaces will respond to biofilm formation when subjected to the stresses experienced

  10. In-Flight Pitot-Static Calibration

    Science.gov (United States)

    Foster, John V. (Inventor); Cunningham, Kevin (Inventor)

    2016-01-01

    A GPS-based pitot-static calibration system uses global output-error optimization. High data rate measurements of static and total pressure, ambient air conditions, and GPS-based ground speed measurements are used to compute pitot-static pressure errors over a range of airspeed. System identification methods rapidly compute optimal pressure error models with defined confidence intervals.

  11. Assessing Static Performance of the Dashengguan Yangtze Bridge by Monitoring the Correlation between Temperature Field and Its Static Strains

    Directory of Open Access Journals (Sweden)

    Gao-Xin Wang

    2015-01-01

    Full Text Available Taking advantage of the structural health monitoring system installed on the steel truss arch girder of Dashengguan Yangtze Bridge, the temperature field data and static strain data are collected and analyzed for the static performance assessment of the bridge. Through analysis, it is found that the static strain changes are mainly caused by temperature field (temperature and temperature difference and train. After the train-induced static strains are removed, the correlation between the remaining static strains and the temperature field shows apparent linear characteristics, which can be mathematically modeled for the description of static performance. Therefore, multivariate linear regression function combined with principal component analysis is introduced to mathematically model the correlation. Furthermore, the residual static strains of mathematical model are adopted as assessment indicator and three kinds of degradation regulations of static performance are obtained after simulation of the residual static strains. Finally, it is concluded that the static performance of Dashengguan Yangtze Bridge was in a good condition during that period.

  12. Relationship between functional assessments and exercise-related changes during static balance.

    Science.gov (United States)

    Clifton, Daniel R; Harrison, Blain C; Hertel, Jay; Hart, Joseph M

    2013-04-01

    The Functional Movement Screen (FMS) is currently used for injury risk prediction, although researchers have not studied its relationships to injury risk factors. The purpose of this study was to compare FMS scores at rest to changes in static balance after exercise. Second, we examined FMS scores pre and post exercise. Twenty-five participants performed center of pressure (COP) measures and FMS testing. An acclimatization session for the FMS occurred on day 1, whereas day 2 involved COP measures for static balance and FMS testing before and after a 36-minute exercise protocol. Center of pressure standard deviations in the frontal (COPML-SD) and sagittal (COPAP-SD) planes, center of pressure velocity (COP-Velocity), center of pressure area (COP-Area), and FMS scores were recorded. No significant correlations occurred between preexercise FMS scores and change in COP measures. Preexercise hurdle step scores related to preexercise COPML-SD (p = -0.46), COPAP-SD (p = -0.43), and COP-Area (p = -0.50). Preexercise in-line lunge scores related to postexercise COPAP-SD (p = -0.44) and COP-Velocity (p = -0.39), whereas preexercise active straight leg raise (ASLR) scores related to postexercise COPML-SD (p = -0.46). Functional Movement Screen scores were not related to changes in static balance after exercise and may therefore not be useful to predict who will experience greater static balance deficits after exercise. Additionally, FMS scores did not differ before and after exercise. Clinicians aiming to identify injury risk from a general static balance standpoint may find the hurdle step, in-line lunge, and ASLR useful. Clinicians aiming to identify injury risk from a change in static balance standpoint may need to explore other screening tools.

  13. A study of the static to kinetic friction transition of polymers

    OpenAIRE

    Lee, Edward Chungjen

    1995-01-01

    This study investigates the transition from static to kinetic friction for structural polymers and continues previous research conducted by Dr. N. S. Eiss, B. McCann, and R. Molique. A new test apparatus which simultaneously measures friction, normal load, and relative velocity was developed to study this transition. The polymers used in this study were nylon, ABS, polycarbonate, and fiberglass filled and unfilled polypropylene. Creep effects of polymers on the static coefficie...

  14. Static Recrystallization Behavior of Z12CN13 Martensite Stainless Steel

    Science.gov (United States)

    Luo, Min; Zhou, Bing; Li, Rong-bin; Xu, Chun; Guo, Yan-hui

    2017-09-01

    In order to increase the hot workability and provide proper hot forming parameters of forging Z12CN13 martensite stainless steel for the simulation and production, the static recrystallization behavior has been studied by double-pass hot compression tests. The effects of deformation temperature, strain rate and inter-pass time on the static recrystallization fraction by the 2% offset method are extensively studied. The results indicate that increasing the inter-pass time and the deformation temperature as well as strain rate appropriately can increase the fraction of static recrystallization. At the temperature of 1050-1150 °C, inter-pass time of 30-100 s and strain rate of 0.1-5 s-1, the static recrystallization behavior is obvious. In addition, the kinetics of static recrystallization behavior of Z12CN13 steel has been established and the activation energy of static recrystallization is 173.030 kJ/mol. The substructure and precipitates have been studied by TEM. The results reveal that the nucleation mode is bulging at grain boundary. Undissolved precipitates such as MoNi3 and Fe3C have a retarding effect on the recrystallization kinetics. The effect is weaker than the accelerating effect of deformation temperature.

  15. The acute effect of static and dynamic stretching during warm-ups on anaerobic performance in trained women

    Directory of Open Access Journals (Sweden)

    rouhollah haghshenas

    2014-09-01

    Full Text Available The purpose of this study was to investigate effects of static stretching, dynamic stretching and no stretching methods on power and speed in volleyball players. Therefore, Twenty-four volleyball players (height: 173.29 ± 7.81 m; mass: 62.12 ± 8.73 kg; age: 22.66 ± 4.02 years; experience: 3.27 ± 6.37 were tested for speed performance using the 20 meter sprint test and also for power using vertical jump test after static stretching, dynamic stretching and no stretching. The results analyzed using ANOVA showed that There was a significant increase in height jump after dynamic stretching against static stretching. But, there were no significant differences between no stretching and static stretching groups. In addition, there was a significant decrease in time 20 meter sprint after dynamic stretching against static stretching and no stretching groups. The results of this study suggest that it may be desirable for volleyball players to perform dynamic exercises before the performance of activities that require a high power output.

  16. The Effect of Water Exercise Program on Static and Dynamic Balance in Elderly Women

    Directory of Open Access Journals (Sweden)

    Heydar Sadeghi

    2008-01-01

    Full Text Available Objectives: Poor balance is one of risk factors of falling, a cause of injury and even death in elderly. The aim of this study was to evaluate the effect of a water exercise program on static and dynamic balance in elder women. Methods & Materials: Thirty participants aged 55-70 years completed an exercise program (60 min, 3 days and 6 weeks, in 2 groups, exercise and control, voluntarily. Static and dynamic balances were measured before and after exercise program in both groups. Postural sway parameters, including mean displacement of center of pressure and velocity of center of pressure in Medio-Lateral (ML and Anterio-Posterior (AP directions, in single stance position, as a measure of static balance and functional reach test, functional reach right test and functional reach left test, as dynamic measure of balance was considered. T test for deepened groups was used for evaluation of changes within groups, and T test for independent groups was used for between groups' changes at threshold of 0.05 After 6 weeks. Results: Significant changes were observed in results of Functional Reach Test (FRT, Functional Reach Left Test (FRLT after exercise program, also in average displacement of cop and velocity of cop in ML direction. Between groups significant differences were observed in results of average cop displacement and velocity of displacement, FRT and FRLT. Conclusion: These results suggest that challenging the physiological systems involved in balance control, in water, while on the non stable support surface, improved both static and dynamic balance and probably might decrease the risk of falling.

  17. An empirical comparison of a dynamic software testability metric to static cyclomatic complexity

    Science.gov (United States)

    Voas, Jeffrey M.; Miller, Keith W.; Payne, Jeffrey E.

    1993-01-01

    This paper compares the dynamic testability prediction technique termed 'sensitivity analysis' to the static testability technique termed cyclomatic complexity. The application that we chose in this empirical study is a CASE generated version of a B-737 autoland system. For the B-737 system we analyzed, we isolated those functions that we predict are more prone to hide errors during system/reliability testing. We also analyzed the code with several other well-known static metrics. This paper compares and contrasts the results of sensitivity analysis to the results of the static metrics.

  18. Influence of Ultrasonic Vibrations on the Static Friction Characteristics of a Rubber/Aluminum Couple

    International Nuclear Information System (INIS)

    Cheng Ting-Hai; Gao Han; Bao Gang

    2011-01-01

    A novel ultrasonic vibration approach is introduced into a chloroprene rubber/aluminum friction couple for improving the static friction properties between rubber and metal. Compared to the test results without vibrations, the static friction force of a chloroprene rubber/aluminum couple decreases observably, leading to the ultimate displacement of rubber. The values of the static friction force and ultimate displacement can be ultimately reduced to 23.1% and 50% of those without ultrasonic vibrations, respectively. (fundamental areas of phenomenology(including applications))

  19. QuickChecking static analysis properties

    DEFF Research Database (Denmark)

    Midtgaard, Jan; Møller, Anders

    2017-01-01

    A static analysis can check programs for potential errors. A natural question that arises is therefore: who checks the checker? Researchers have given this question varying attention, ranging from basic testing techniques, informal monotonicity arguments, thorough pen-and-paper soundness proofs....... Moreover, we offer a number of generic, type-safe combinators to check transfer functions and operators on lattices, to help ensure that these are, eg, monotone, strict, or invariant. We substantiate our claims by quickchecking a type analysis for the Lua programming language....

  20. Rethinking the neurological examination I: static balance assessment

    Directory of Open Access Journals (Sweden)

    Péricles A. Maranhão-Filho

    2011-12-01

    Full Text Available The authors advocate a modernization of the neurologic exam with regard to the evaluation of static equilibrium through the application of some easily performed and interpreted bedside maneuvers like the Clinical Test of Sensory Integration and Balance - modified and the Functional Reach Test. The authors also believe that these and other assessments, such as that of the risk of falling for elderly patients, should be incorporated into the routine neurological examination.

  1. Kinect-based sign language recognition of static and dynamic hand movements

    Science.gov (United States)

    Dalawis, Rando C.; Olayao, Kenneth Deniel R.; Ramos, Evan Geoffrey I.; Samonte, Mary Jane C.

    2017-02-01

    A different approach of sign language recognition of static and dynamic hand movements was developed in this study using normalized correlation algorithm. The goal of this research was to translate fingerspelling sign language into text using MATLAB and Microsoft Kinect. Digital input image captured by Kinect devices are matched from template samples stored in a database. This Human Computer Interaction (HCI) prototype was developed to help people with communication disability to express their thoughts with ease. Frame segmentation and feature extraction was used to give meaning to the captured images. Sequential and random testing was used to test both static and dynamic fingerspelling gestures. The researchers explained some factors they encountered causing some misclassification of signs.

  2. Comparison of experimental measurements of power MOSFET SEBs in dynamic and static modes

    International Nuclear Information System (INIS)

    Calvel, P.; Peyrotte, C.; Baiget, A.; Stassinopoulos, E.G.

    1991-01-01

    In this paper a study to determine the Single Event Burnout (SEB) sensitivity for burnout of IRF-150 Power MOSFETs in both static and dynamic modes in terms of LET threshold and cross section is described. The dynamic tests were conducted with a power converter which was designed for actual space application. The results were compared with static measurements which were made during the exposure to the heavy ions. The data showed that the dynamic mode was less sensitive than the static by two orders of magnitude in cross section. It was also observed that ions with a range less than 30 microns did not produce destructive burnout in the dynamic mode even when their LET exceeded the threshold value. The extent of physical MOSFET damage in the destructive, dynamic tests appeared to correlate with the ion LET and source-drain voltage

  3. Static and Dynamic Balance in Congenital Severe to Profound Hearing-Impaired Children

    Directory of Open Access Journals (Sweden)

    Farideh HajiHeydari

    2011-09-01

    Full Text Available Background and Aim: Research conducted since the early 1900s has consistently identified differences between deaf and hearing children on performance of a wide variety of motor tasks, most notably balance. Our study was performed to test static and dynamic balance skills in congenital severe to profound hearing impaired children in comparison with normal age-matched children.Methods: This cross-sectional study was conducted on 30 severe to profound hearing impaired and 40 normal children with age 6 to 10 years old. Bruininks-Oseretsky test of motor proficiency 2, balance subset with 9 parts was used for evaluation of balance skills.Results: Hearing-impaired children showed 16.7 to 100% fail results in 7 parts of the balance subset. In normal children fail result was revealed just in 3 parts of the balance subset from 2.5 to 57.5%, and differences between two groups were significant (p<0.0001. There was a significant difference between two groups in two static balance skills of standing on one leg on a line and standing on one leg on a balance beam with eyes closed (p<0.0001.conclusion: It seems that development of static balance skills are longer than dynamic ones. Because severe to profound hearing-impaired children showed more weakness than normal children in both static and dynamic balance abilities, functional tests of balance proficiency can help to identify balance disorders in these children.

  4. RELATION BETWEEN THE PHYSICAL WORKING CAPACITY (PWC170 AND STATIC RELATIVE STRENGTH

    Directory of Open Access Journals (Sweden)

    Abdulla Elezi

    2012-09-01

    Full Text Available Determining the relationship within the segments, and establish the correlation between the functional and motor areas may be important for programming load both in education and in sports and recreation. For this reason we set goals and work this year. The main objective of this research is to determine association and motor characteristics impact on functional ability (physical work capacity. The sample is defined as a sample of 263 respondents drawn from the population of secondary schools: Gymnasium Zenel Hajdini; Marin Barleti and Mehmet Isai in city of Gjilan. Nine tests were used to estimate motoric capabilities and a test of functional capacity of aerobic-type (physical work capacity. To determine the relation between the predictor (motor variables and criterion variables (physical working capacity - PWC170 it is prepared the regression analysis of the manifest space. Analyses were made to the program SPSS 12.0 for Windows. The connection of the entire system of variables static relative strength with a score of Physics working capacity (PWC170 on a bicycle ergo meter as aerobic type variable explains the coefficient of multiple correlations, which is RO 0.394. Regression analysis indicates that the better results on a bicycle ergo meter will have respondents who score better in tests of static relative strength of the leg (at the test isometric muscle contraction quadriceps thighs and static tests of the relative strength of arm and shoulder area (at the test of isometric contraction triceps muscle circumference.

  5. A Micro Dynamically Tuned Gyroscope with Adjustable Static Capacitance

    Directory of Open Access Journals (Sweden)

    Lun Kong

    2013-02-01

    Full Text Available This paper presents a novel micro dynamically tuned gyroscope (MDTG with adjustable static capacitance. First, the principle of MDTG is theoretically analyzed. Next, some simulations under the optimized structure parameters are given as a reference for the mask design of the rotor wafer and electrode plates. As two key components, the process flows of the rotor wafer and electrode plates are described in detail. All the scanning electron microscopy (SEM photos show that the fabrication process is effective and optimized. Then, an assembly model is designed for the static capacitance adjustable MDTG, whose static capacitance can be changed by rotating the lower electrode plate support and substituting gasket rings of different thicknesses. Thus, the scale factor is easily changeable. Afterwards, the digitalized closed-loop measurement circuit is simulated. The discrete correction and decoupling modules are designed to make the closed-loop stable and cross-coupling effect small. The dual axis closed-loop system bandwidths can reach more than 60 Hz and the dual axis scale factors are completely symmetrical. All the simulation results demonstrate the proposed fabrication of the MDTG can meet the application requirements. Finally, the paper presents the test results of static and dynamic capacitance values which are consistent with the simulation values.

  6. COMPARISON OF USER PERFORMANCE WITH INTERACTIVE AND STATIC 3D VISUALIZATION – PILOT STUDY

    Directory of Open Access Journals (Sweden)

    L. Herman

    2016-06-01

    Full Text Available Interactive 3D visualizations of spatial data are currently available and popular through various applications such as Google Earth, ArcScene, etc. Several scientific studies have focused on user performance with 3D visualization, but static perspective views are used as stimuli in most of the studies. The main objective of this paper is to try to identify potential differences in user performance with static perspective views and interactive visualizations. This research is an exploratory study. An experiment was designed as a between-subject study and a customized testing tool based on open web technologies was used for the experiment. The testing set consists of an initial questionnaire, a training task and four experimental tasks. Selection of the highest point and determination of visibility from the top of a mountain were used as the experimental tasks. Speed and accuracy of each task performance of participants were recorded. The movement and actions in the virtual environment were also recorded within the interactive variant. The results show that participants deal with the tasks faster when using static visualization. The average error rate was also higher in the static variant. The findings from this pilot study will be used for further testing, especially for formulating of hypotheses and designing of subsequent experiments.

  7. QuickChecking Static Analysis Properties

    DEFF Research Database (Denmark)

    Midtgaard, Jan; Møller, Anders

    2015-01-01

    A static analysis can check programs for potential errors. A natural question that arises is therefore: who checks the checker? Researchers have given this question varying attention, ranging from basic testing techniques, informal monotonicity arguments, thorough pen-and-paper soundness proofs...... of a lattice. Moreover, we offer a number of generic, type-safe combinators to check transfer functions and operators on lattices, to help ensure that these are, e.g., monotone, strict, or invariant. We substantiate our claims by quickchecking a type analysis for the Lua programming language...

  8. Residual stresses under quasi-static and cyclic loading in shot peened Inconel 718

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmeister, Juergen; Schulze, Volker [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany). Inst. for Applied Materials; Hessert, Roland; Koenig, Gerhard [MTU Aero Engines, Munich (Germany)

    2012-01-15

    The residual stress state induced by shot peening should be taken into account in the dimensioning of turbine components. Understanding the changes in the residual stress state caused by the application of quasi-static and cyclic loads is a prerequisite. In order to describe the residual stress state after quasi-static loading, several different shot peened Inconel 718 specimens were loaded isothermally up to specific tensile loadings. To analyze the residual stress state after cyclic loading, isothermal low cycle fatigue tests were performed. These tests were stopped after a defined number of cycles. Finally, after the specimens had been subjected to different loads, the surface residual stresses and - for special loadings - the residual stress depth distributions were determined experimentally by using X-ray diffraction. The surface - core model was adapted so that the complete residual stress depth distribution after quasi-static and cyclic loading can now be described. (orig.)

  9. Quasi-Static Indentation Analysis of Carbon-Fiber Laminates.

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, Timothy [Sandia National Lab. (SNL-CA), Livermore, CA (United States); English, Shawn Allen [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Nelson, Stacy Michelle [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-12-01

    A series of quasi - static indentation experiments are conducted on carbon fiber reinforced polymer laminates with a systematic variation of thicknesses and fixture boundary conditions. Different deformation mechanisms and their resulting damage mechanisms are activated b y changing the thickn ess and boundary conditions. The quasi - static indentation experiments have been shown to achieve damage mechanisms similar to impact and penetration, however without strain rate effects. The low rate allows for the detailed analysis on the load response. Moreover, interrupted tests allow for the incremental analysis of various damage mechanisms and pr ogressions. The experimentally tested specimens are non - destructively evaluated (NDE) with optical imaging, ultrasonics and computed tomography. The load displacement responses and the NDE are then utilized in numerical simulations for the purpose of model validation and vetting. The accompanying numerical simulation work serves two purposes. First, the results further reveal the time sequence of events and the meaning behind load dro ps not clear from NDE . Second, the simulations demonstrate insufficiencies in the code and can then direct future efforts for development.

  10. Static Computer Memory Integrity Testing (SCMIT): An experiment flown on STS-40 as part of GAS payload G-616

    Science.gov (United States)

    Hancock, Thomas

    1993-01-01

    This experiment investigated the integrity of static computer memory (floppy disk media) when exposed to the environment of low earth orbit. The experiment attempted to record soft-event upsets (bit-flips) in static computer memory. Typical conditions that exist in low earth orbit that may cause soft-event upsets include: cosmic rays, low level background radiation, charged fields, static charges, and the earth's magnetic field. Over the years several spacecraft have been affected by soft-event upsets (bit-flips), and these events have caused a loss of data or affected spacecraft guidance and control. This paper describes a commercial spin-off that is being developed from the experiment.

  11. THE ROLE OF LEG AND TRUNK MUSCLES PROPRIOCEPTION ON STATIC AND DYNAMIC POSTURAL CONTROL

    Directory of Open Access Journals (Sweden)

    SEYED Hossein Hosseinimehr

    2010-04-01

    Full Text Available The proprioception information is a prerequisite for balance, body’s navigation system, and the movement coordinator. Due to changes between the angles of ankle, knee, and hip joints the aforementioned information are important in the coordination of the limbs and postural balance. The aim of this study was to investigate therole of leg and trunk muscles proprioception on static and dynamic postural control. Thirty males students of physical education and sport sciences (age =21.23 ± 2.95 years, height = 170.4 ± 5.1 cm, and weight = 70.7 ± 5.6 kg participated in this study volunteered. Vibration (100HZ was used to disturb of proprioception. Vibrationoperated on leg muscle (gasterocnemius and trunk muscles (erector spine muscle, at L1 level. Leg stance time and Star Excursion Balance Test were used for evaluation of static and dynamic postural control respectively.Subjects performed pre and post (with operated vibration leg stance time and star excursion balance test. Paired sample test used for investigation the effect of vibration on leg and trunk muscles in static and dynamic postural control. Result of this study showed in static postural control, there is no significant difference between pre and post test (operated vibration in leg and trunk muscles (p≤0.05. In contrast there is significant difference indynamic postural control between pre and post test in leg muscles in 8 directions of star excursion balance test (p≤0.05 while there is only significant difference in trunk muscle in antrolateral and lateral of star excursion balance test (p≤0.05. During physical training such conditions like fatigue and injury can disturbproprioceptions’ information. Thus, due to the importance of this information we recommend that coaches'additionally specific trainings any sport used specific exercises to enhance the proprioception information

  12. An improved EMD method for modal identification and a combined static-dynamic method for damage detection

    Science.gov (United States)

    Yang, Jinping; Li, Peizhen; Yang, Youfa; Xu, Dian

    2018-04-01

    Empirical mode decomposition (EMD) is a highly adaptable signal processing method. However, the EMD approach has certain drawbacks, including distortions from end effects and mode mixing. In the present study, these two problems are addressed using an end extension method based on the support vector regression machine (SVRM) and a modal decomposition method based on the characteristics of the Hilbert transform. The algorithm includes two steps: using the SVRM, the time series data are extended at both endpoints to reduce the end effects, and then, a modified EMD method using the characteristics of the Hilbert transform is performed on the resulting signal to reduce mode mixing. A new combined static-dynamic method for identifying structural damage is presented. This method combines the static and dynamic information in an equilibrium equation that can be solved using the Moore-Penrose generalized matrix inverse. The combination method uses the differences in displacements of the structure with and without damage and variations in the modal force vector. Tests on a four-story, steel-frame structure were conducted to obtain static and dynamic responses of the structure. The modal parameters are identified using data from the dynamic tests and improved EMD method. The new method is shown to be more accurate and effective than the traditional EMD method. Through tests with a shear-type test frame, the higher performance of the proposed static-dynamic damage detection approach, which can detect both single and multiple damage locations and the degree of the damage, is demonstrated. For structures with multiple damage, the combined approach is more effective than either the static or dynamic method. The proposed EMD method and static-dynamic damage detection method offer improved modal identification and damage detection, respectively, in structures.

  13. Energy conversion statics

    CERN Document Server

    Messerle, H K; Declaris, Nicholas

    2013-01-01

    Energy Conversion Statics deals with equilibrium situations and processes linking equilibrium states. A development of the basic theory of energy conversion statics and its applications is presented. In the applications the emphasis is on processes involving electrical energy. The text commences by introducing the general concept of energy with a survey of primary and secondary energy forms, their availability, and use. The second chapter presents the basic laws of energy conversion. Four postulates defining the overall range of applicability of the general theory are set out, demonstrating th

  14. Estimation of static parameters based on dynamical and physical properties in limestone rocks

    Science.gov (United States)

    Ghafoori, Mohammad; Rastegarnia, Ahmad; Lashkaripour, Gholam Reza

    2018-01-01

    Due to the importance of uniaxial compressive strength (UCS), static Young's modulus (ES) and shear wave velocity, it is always worth to predict these parameters from empirical relations that suggested for other formations with same lithology. This paper studies the physical, mechanical and dynamical properties of limestone rocks using the results of laboratory tests which carried out on 60 the Jahrum and the Asmari formations core specimens. The core specimens were obtained from the Bazoft dam site, hydroelectric supply and double-curvature arch dam in Iran. The Dynamic Young's modulus (Ed) and dynamic Poisson ratio were calculated using the existing relations. Some empirical relations were presented to estimate uniaxial compressive strength, as well as static Young's modulus and shear wave velocity (Vs). Results showed the static parameters such as uniaxial compressive strength and static Young's modulus represented low correlation with water absorption. It is also found that the uniaxial compressive strength and static Young's modulus had high correlation with compressional wave velocity and dynamic Young's modulus, respectively. Dynamic Young's modulus was 5 times larger than static Young's modulus. Further, the dynamic Poisson ratio was 1.3 times larger than static Poisson ratio. The relationship between shear wave velocity (Vs) and compressional wave velocity (Vp) was power and positive with high correlation coefficient. Prediction of uniaxial compressive strength based on Vp was better than that based on Vs . Generally, both UCS and static Young's modulus (ES) had good correlation with Ed.

  15. Analog automatic test pattern generation for quasi-static structural test.

    NARCIS (Netherlands)

    Zjajo, A.; Pineda de Gyvez, J.

    2009-01-01

    A new approach for structural, fault-oriented analog test generation methodology to test for the presence of manufacturing-related defects is proposed. The output of the test generator consists of optimized test stimuli, fault coverage and sampling instants that are sufficient to detect the failure

  16. A Pedagogical Model of Static Friction

    OpenAIRE

    Pickett, Galen T.

    2015-01-01

    While dry Coulombic friction is an elementary topic in any standard introductory course in mechanics, the critical distinction between the kinetic and static friction forces is something that is both hard to teach and to learn. In this paper, I describe a geometric model of static friction that may help introductory students to both understand and apply the Coulomb static friction approximation.

  17. Instance Analysis for the Error of Three-pivot Pressure Transducer Static Balancing Method for Hydraulic Turbine Runner

    Science.gov (United States)

    Weng, Hanli; Li, Youping

    2017-04-01

    The working principle, process device and test procedure of runner static balancing test method by weighting with three-pivot pressure transducers are introduced in this paper. Based on an actual instance of a V hydraulic turbine runner, the error and sensitivity of the three-pivot pressure transducer static balancing method are analysed. Suggestions about improving the accuracy and the application of the method are also proposed.

  18. Comparing numerically exact and modelled static friction

    Directory of Open Access Journals (Sweden)

    Krengel Dominik

    2017-01-01

    Full Text Available Currently there exists no mechanically consistent “numerically exact” implementation of static and dynamic Coulomb friction for general soft particle simulations with arbitrary contact situations in two or three dimension, but only along one dimension. We outline a differential-algebraic equation approach for a “numerically exact” computation of friction in two dimensions and compare its application to the Cundall-Strack model in some test cases.

  19. Characterization of the mechanical properties of a dermal equivalent compared with human skin in vivo by indentation and static friction tests.

    Science.gov (United States)

    Zahouani, H; Pailler-Mattei, C; Sohm, B; Vargiolu, R; Cenizo, V; Debret, R

    2009-02-01

    The study of changes in skin structure with age is becoming all the more important with the increase in life. The atrophy that occurs during aging is accompanied by more profound changes, with a loss of organization within the elastic collagen network and alterations in the basal elements. The aim of this study is to present a method to determine the mechanical properties of total human skin in vivo compared with dermal equivalents (DEs) using indentation and static friction tests. A new bio-tribometer working at a low contact pressure for the characterization the mechanical properties of the skin has been developed. This device, based on indentation and static friction tests, also allows to characterize the skin in vivo and reconstructed DEs in a wide range of light contact forces, stress and strain. This original bio-tribometer shows the ability to assess the skin elasticity and friction force in a wide range of light normal load (0.5-2 g) and low contact pressure (0.5-2 kPa). The results obtained by this approach show identical values of the Young's modulus E(*) and the shear modulus G(*) of six DEs obtained from a 62-year-old subject (E(*)=8.5+/-1.74 kPa and G(*)=3.3+/-0.46 kPa) and in vivo total skin of 20 subjects aged 55 to 70 years (E(*)=8.3+/-2.1 kPa, G(*)=2.8+/-0.8 kpa).

  20. STUDY TO COMPARE THE EFFECTIVENESS OF STATIC STRETCH AND HOLD RELAX TECHNIQUE OVER HAMSTRING FLEXIBILITY

    Directory of Open Access Journals (Sweden)

    Shanthi C

    2014-10-01

    Full Text Available Background: Numerous studies have documented on flexibility of muscles. Flexibility is defined as the ability of the muscles to lengthen allowing one joint or more than one joint in a series to move through a range of motion .Flexibility allows tissue to accommodate more easily to stress thus minimizing or preventing muscle injury. But this study sought to identify the study to compare the effectiveness of Static stretch and Hold relax technique over the hamstring flexibility. Methods: 30 healthy male adults with Hamstring tightness aged 21 to 35 years selected from general population through simple randomized technique. Samples are divided into two groups, static stretch Group-I(no.15 and Group-II Hold relax (no.=15.The outcome was measured with help of sit & reach test to see the Hamstring flexibility. Results: Comparison of the post test values of the group I and group II shows a significant difference between the outcomes of two groups with a “t” calculated value of 0.738 (unpaired “t” test. Conclusion: Both static stretch and hold relax Technique can cause very highly significant result in Hamstring Flexibility, further comparison shows very high significant difference between two groups and concludes that hold relax is better than static stretch in Hamstring Flexibility.

  1. Statics of Historic Masonry Constructions

    CERN Document Server

    Como, Mario

    2013-01-01

    Masonry constructions are the great majority of the buildings in Europe’s historic centres and the most important monuments in its architectural heritage. Given the age of much of these constructions, the demand for safety assessments and restoration projects is pressing and constant. This book aims to help fill this demand presenting a comprehensive new statics of masonry constructions. The book, result of thirty years of research and professional experience, gives the fundamentals of statics of the masonry solid, then applied to the study of statics of arches, piers and vaults. Further, combining engineering and architecture and through an interdisciplinary approach, the book investigates the statical behaviour of many historic monuments, as the Pantheon, the Colosseum,  the domes of S. Maria del Fiore in Florence and of St. Peter in Rome, the Tower of Pisa, the Gothic Cathedrals and the Masonry Buildings under seismic actions.

  2. Static Transition Compression

    DEFF Research Database (Denmark)

    Danvy, Olivier; Damian, Daniel

    2001-01-01

    Starting from an operational specification of a translation from a structured to an unstructured imperative language, we point out how a compositional and context-insensitive translation gives rise to static chains of jumps. Taking an inspiration from the notion of continuation, we state a new...... compositional and context-sensitive specification that provably gives rise to no static chains of jumps, no redundant labels, and no unused labels. It is defined with one inference rule per syntactic construct and operates in linear time and space on the size of the source program (indeed it operates in one...

  3. Statics and Mechanics of Structures

    DEFF Research Database (Denmark)

    Krenk, Steen; Høgsberg, Jan Becker

    The statics and mechanics of structures form a core aspect of civil engineering. This book provides an introduction to the subject, starting from classic hand-calculation types of analysis and gradually advancing to a systematic form suitable for computer implementation. It starts with statically...

  4. Static and dynamic thyroid scintigraphy

    International Nuclear Information System (INIS)

    Mahlstedt, J.

    1986-01-01

    Static images as isolated investigation in thyroid diagnosis mainly provides morphologic information, and therefore sonography is largely applied for this purpose. 99m Tc-pertechnetate scans or 123 I-scans are indicated in cases of malpositions and serve to clarify lesions of unknown dignity. Additionally 201 Tl-chloride is suited for examinations with regard to metabolically active thyroid tissue, whereby differential diagnostic laboratory tests must be carried out to exclude parathyroid adenoma. Dynamic thyroid scans before and after regulation tests (suppression, stimulation) reflect the physiological correlation between the iodine avidity of the thyroid, the peripheral thyroid hormone concentrations and the hypophyseal regulation in the TRH-test. The main application of this procedure is the clarification of thyroid autonomy, i.e. indication, detection, quantification or exclusion of thyroid autonomy. For the treatment of immunogenic thyrotoxicosis, dynamic thyroid scintigraphy provides important information about the onset of remission, thus permitting to end thyreostatic therapy. (orig.) [de

  5. Comparison of static and high strain dynamic tests on driven steel piles at several industrial sites in Alberta

    Energy Technology Data Exchange (ETDEWEB)

    Tweedie, R.; Clementino, R.; Law, D. [Thurber Engineering Ltd., Edmonton, AB (Canada)

    2009-07-01

    Many of the foundations at industrial plants in northern Alberta are supported by driven steel piles that are often installed through thick glacial clay and sand deposits. This paper presented 3 case histories where static load tests (SLT) and high strain dynamic tests (HSDT) were conducted on the driven steel piles. The soil conditions and typical pile sizes used at the 3 sites were described. The first site was an oilsand processing facility where steam assisted gravity drainage (SAGD) was used for bitumen production from oilsand. The second site was a petrochemical plant and the third site was a power plant. The case histories revealed the importance of combining SLT and HSDT to optimize pile designs. The paper emphasized the benefits of undertaking the pile load tests during the design phase, when the potential benefits of obtaining higher capacities can be effectively applied to the pile designs. It was concluded that pile design based on Limit States Design (LSD) in accordance with NBC 2005 must satisfy the Ultimate Limit States (ULS) to prevent plunging failure and also Serviceability Limit States (SLS) to maintain tolerable settlement. 10 refs., 5 tabs., 7 figs.

  6. Static Posturography in Aging and Parkinson's disease

    Directory of Open Access Journals (Sweden)

    Guntram W. Ickenstein

    2012-08-01

    Full Text Available Introduction: In clinical practise, evaluation of postural control is based on the neurological examination, including Romberg’s test, examination of gait and performance of pull test as part of the Unified Parkinson´s Disease Rating Scale (UPDRS. The goal of our study was to identify posturographic parameters since quantitative technical methods for the measurement of postural control are not established in clinical routine yet. Methods: In this cross-sectional study design we examined patients with Parkinson's disease (Hoehn & Yahr <3; PD n=12 on a static posturographic platform (eyes open and eyes closed, performing a standard Romberg’s test during neurological examination and compared the results with an age-matched control group (healthy adult control; HAC n=10 and a healthy young control (HYC n=21.Results: In the platform Romberg’s test with open eyes, the patients with Parkinson’s disease (PD showed a significantly greater mean sway (PD: 14.98 vs. HAC: 8.77 [mm], p<0.003 vs. HYC 7.80 [mm], greater mean radius (PD: 28.31 vs. HAC: 16.36 [mm], p<0.008 vs. HYC: 14.19 [mm] and greater marked area (PD: 2.38 vs. HAC: 0.88 [cm2], p<0.016 vs. HYC: 0.78 [cm2] compared to the healthy adult control (HAC. The Romberg’s test with closed eyes revealed a significantly greater mean sway (PD: 13.83 vs. HAC: 10.12 [mm], p<0.033 vs. HYC: 5.82 [mm] and greater mean radius (PD: 25.03 vs. HAC: 18.15 [mm], p<0.045 vs. HYC: 9.11 [mm] compared to both groups.Conclusions: The platform Romberg test with closed eyes detected significant differences in elderly people and patients with Parkinson's disease, which could be objectively quantified with static posturography testing. Age alone showed significant changes, only detectable with closed eyes. Therefore balance testing with a new computerized approach could help to identify balance problems in a geriatric assessment in clinical routine, especially with the parameters marked area and mean sway.

  7. STATIC{sub T}EMP: a useful computer code for calculating static formation temperatures in geothermal wells

    Energy Technology Data Exchange (ETDEWEB)

    Santoyo, E. [Universidad Nacional Autonoma de Mexico, Centro de Investigacion en Energia, Temixco (Mexico); Garcia, A.; Santoyo, S. [Unidad Geotermia, Inst. de Investigaciones Electricas, Temixco (Mexico); Espinosa, G. [Universidad Autonoma Metropolitana, Co. Vicentina (Mexico); Hernandez, I. [ITESM, Centro de Sistemas de Manufactura, Monterrey (Mexico)

    2000-07-01

    The development and application of the computer code STATIC{sub T}EMP, a useful tool for calculating static formation temperatures from actual bottomhole temperature data logged in geothermal wells is described. STATIC{sub T}EMP is based on five analytical methods which are the most frequently used in the geothermal industry. Conductive and convective heat flow models (radial, spherical/radial and cylindrical/radial) were selected. The computer code is a useful tool that can be reliably used in situ to determine static formation temperatures before or during the completion stages of geothermal wells (drilling and cementing). Shut-in time and bottomhole temperature measurements logged during well completion activities are required as input data. Output results can include up to seven computations of the static formation temperature by each wellbore temperature data set analysed. STATIC{sub T}EMP was written in Fortran-77 Microsoft language for MS-DOS environment using structured programming techniques. It runs on most IBM compatible personal computers. The source code and its computational architecture as well as the input and output files are described in detail. Validation and application examples on the use of this computer code with wellbore temperature data (obtained from specialised literature) and with actual bottomhole temperature data (taken from completion operations of some geothermal wells) are also presented. (Author)

  8. Failure mechanism and coupled static-dynamic loading theory in deep hard rock mining: A review

    Directory of Open Access Journals (Sweden)

    Xibing Li

    2017-08-01

    Full Text Available Rock failure phenomena, such as rockburst, slabbing (or spalling and zonal disintegration, related to deep underground excavation of hard rocks are frequently reported and pose a great threat to deep mining. Currently, the explanation for these failure phenomena using existing dynamic or static rock mechanics theory is not straightforward. In this study, new theory and testing method for deep underground rock mass under coupled static-dynamic loading are introduced. Two types of coupled loading modes, i.e. “critical static stress + slight disturbance” and “elastic static stress + impact disturbance”, are proposed, and associated test devices are developed. Rockburst phenomena of hard rocks under coupled static-dynamic loading are successfully reproduced in the laboratory, and the rockburst mechanism and related criteria are demonstrated. The results of true triaxial unloading compression tests on granite and red sandstone indicate that the unloading can induce slabbing when the confining pressure exceeds a certain threshold, and the slabbing failure strength is lower than the shear failure strength according to the conventional Mohr-Column criterion. Numerical results indicate that the rock unloading failure response under different in situ stresses and unloading rates can be characterized by an equivalent strain energy density. In addition, we present a new microseismic source location method without premeasuring the sound wave velocity in rock mass, which can efficiently and accurately locate the rock failure in hard rock mines. Also, a new idea for deep hard rock mining using a non-explosive continuous mining method is briefly introduced.

  9. Statics and mechanics of structures

    CERN Document Server

    Krenk, Steen

    2013-01-01

    The statics and mechanics of structures form a core aspect of civil engineering. This book provides an introduction to the subject, starting from classic hand-calculation types of analysis and gradually advancing to a systematic form suitable for computer implementation. It starts with statically determinate structures in the form of trusses, beams and frames. Instability is discussed in the form of the column problem - both the ideal column and the imperfect column used in actual column design. The theory of statically indeterminate structures is then introduced, and the force and deformation methods are explained and illustrated. An important aspect of the book’s approach is the systematic development of the theory in a form suitable for computer implementation using finite elements. This development is supported by two small computer programs, MiniTruss and MiniFrame, which permit static analysis of trusses and frames, as well as linearized stability analysis. The book’s final section presents related ...

  10. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99m Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  11. Static strain aging type AISI-304 austenitic stainless steel

    International Nuclear Information System (INIS)

    Trindade, M.B.

    1981-03-01

    Static strain aging of type AISI-304 austenitic stainless steel was studied from room temperature up to 623K by conducting tests in which the load was held approximately constant, continuously relaxing and unloaded. The aging times varied between 10s and 100h, using a plastic pre deformation of 9% in most of the cases. The static strain aging of 304 steel furnished an activation energy of 23,800 cal/mol. This implies that vacancies play an important role on the aging process. The curve of the variation of the discontinuous yielding with aging time presented different stages, to which specific mathematical expressions were developed. These facts permited the conclusion that Snoek type mechanisms are responsible for the aging in such conditions. (Author) [pt

  12. Static Members of Classes in C#

    Directory of Open Access Journals (Sweden)

    Adrian LUPASC

    2017-12-01

    Full Text Available The C# language is object-oriented, which is why the declared member data must be part of a class. Thus, there is no possibility to declare certain variables that can be accessed from anywhere within the application, as it happens, for example, with global variables at the C language level. Making this work in C# is possible through static members of the class. Declaring a class implies defining some of its member data that later receive values when creating each object. A static member of the class can be interpreted as belonging only to the class, not to the objects subsequently created, which means that for the non-static data, there are as many children as there were objects created, while for the static ones there is only one copy, regardless of the number of created objects. In this regard, this paper presents the main aspects that characterize these abstract concepts of object oriented programming in general and C# language in particular, detailing how to develop an application that includes both static and non-static members. At the same time, particularities in the mirror for the two types of data, restrictions on use and potential limitations are presented.

  13. Magnetic fields and accretion discs around static black holes

    International Nuclear Information System (INIS)

    Dadhich, N.

    1982-01-01

    Some aspects of accretion onto static black holes immersed in a uniform magnetic field are investigated. The Ernst metric is employed to find the 'Keplerian' angular momentum distribution and the efficiency of mass-to-energy conversion for a plasma and for test particles. Under almost all physically reasonable conditions for hydrodynamic accretion the effect of the magnetic field is small. However, for test particles the effect can be very important and the efficiency can approach unity. (author)

  14. Recognition of dance-like actions: memory for static posture or dynamic movement?

    Science.gov (United States)

    Vicary, Staci A; Robbins, Rachel A; Calvo-Merino, Beatriz; Stevens, Catherine J

    2014-07-01

    Dance-like actions are complex visual stimuli involving multiple changes in body posture across time and space. Visual perception research has demonstrated a difference between the processing of dynamic body movement and the processing of static body posture. Yet, it is unclear whether this processing dissociation continues during the retention of body movement and body form in visual working memory (VWM). When observing a dance-like action, it is likely that static snapshot images of body posture will be retained alongside dynamic images of the complete motion. Therefore, we hypothesized that, as in perception, posture and movement would differ in VWM. Additionally, if body posture and body movement are separable in VWM, as form- and motion-based items, respectively, then differential interference from intervening form and motion tasks should occur during recognition. In two experiments, we examined these hypotheses. In Experiment 1, the recognition of postures and movements was tested in conditions in which the formats of the study and test stimuli matched (movement-study to movement-test, posture-study to posture-test) or mismatched (movement-study to posture-test, posture-study to movement-test). In Experiment 2, the recognition of postures and movements was compared after intervening form and motion tasks. These results indicated that (1) the recognition of body movement based only on posture is possible, but it is significantly poorer than recognition based on the entire movement stimulus, and (2) form-based interference does not impair memory for movements, although motion-based interference does. We concluded that, whereas static posture information is encoded during the observation of dance-like actions, body movement and body posture differ in VWM.

  15. K-11 students’ creative thinking ability on static fluid: a case study

    Science.gov (United States)

    Hanni, I. U.; Muslim; Hasanah, L.; Samsudin, A.

    2018-05-01

    Creative thinking is one of the fundamental components of 21st-century education that needs to be possessed and developed in students. Thus, the students have the ability to find many alternative solutions to solve problems in physics learning. The study aimed at providing the students’ creative thinking ability on Static Fluid. A case study has been implemented through a single case, namely embedded design. Participants in this study are 27 K-11 students. The instrument utilized is Test for Creative Thinking-Static Fluid (TCT-SF) which has been validated by the experts. The result shows that 10.74 (approximately 35.8%) of the maximum scores. In conclusion, students’ creative thinking ability on Static Fluid is still stumpy, hence, it is needed to develop creative thinking ability in K-11 students’ context.

  16. Aerodynamic characteristics of a large-scale semispan model with a swept wing and an augmented jet flap with hypermixing nozzles. [Ames 40- by 80-Foot Wind Tunnel and Static Test Facility

    Science.gov (United States)

    Aiken, T. N.; Falarski, M. D.; Koenin, D. G.

    1979-01-01

    The aerodynamic characteristics of the augmentor wing concept with hypermixing primary nozzles were investigated. A large-scale semispan model in the Ames 40- by 80-Foot Wind Tunnel and Static Test Facility was used. The trailing edge, augmentor flap system occupied 65% of the span and consisted of two fixed pivot flaps. The nozzle system consisted of hypermixing, lobe primary nozzles, and BLC slot nozzles at the forward inlet, both sides and ends of the throat, and at the aft flap. The entire wing leading edge was fitted with a 10% chord slat and a blowing slot. Outboard of the flap was a blown aileron. The model was tested statically and at forward speed. Primary parameters and their ranges included angle of attack from -12 to 32 degrees, flap angles of 20, 30, 45, 60 and 70 degrees, and deflection and diffuser area ratios from 1.16 to 2.22. Thrust coefficients ranged from 0 to 2.73, while nozzle pressure ratios varied from 1.0 to 2.34. Reynolds number per foot varied from 0 to 1.4 million. Analysis of the data indicated a maximum static, gross augmentation of 1.53 at a flap angle of 45 degrees. Analysis also indicated that the configuration was an efficient powered lift device and that the net thrust was comparable with augmentor wings of similar static performance. Performance at forward speed was best at a diffuser area ratio of 1.37.

  17. FEM Modeling of the Relationship between the High-Temperature Hardness and High-Temperature, Quasi-Static Compression Experiment.

    Science.gov (United States)

    Zhang, Tao; Jiang, Feng; Yan, Lan; Xu, Xipeng

    2017-12-26

    The high-temperature hardness test has a wide range of applications, but lacks test standards. The purpose of this study is to develop a finite element method (FEM) model of the relationship between the high-temperature hardness and high-temperature, quasi-static compression experiment, which is a mature test technology with test standards. A high-temperature, quasi-static compression test and a high-temperature hardness test were carried out. The relationship between the high-temperature, quasi-static compression test results and the high-temperature hardness test results was built by the development of a high-temperature indentation finite element (FE) simulation. The simulated and experimental results of high-temperature hardness have been compared, verifying the accuracy of the high-temperature indentation FE simulation.The simulated results show that the high temperature hardness basically does not change with the change of load when the pile-up of material during indentation is ignored. The simulated and experimental results show that the decrease in hardness and thermal softening are consistent. The strain and stress of indentation were analyzed from the simulated contour. It was found that the strain increases with the increase of the test temperature, and the stress decreases with the increase of the test temperature.

  18. FEM Modeling of the Relationship between the High-Temperature Hardness and High-Temperature, Quasi-Static Compression Experiment

    Directory of Open Access Journals (Sweden)

    Tao Zhang

    2017-12-01

    Full Text Available The high-temperature hardness test has a wide range of applications, but lacks test standards. The purpose of this study is to develop a finite element method (FEM model of the relationship between the high-temperature hardness and high-temperature, quasi-static compression experiment, which is a mature test technology with test standards. A high-temperature, quasi-static compression test and a high-temperature hardness test were carried out. The relationship between the high-temperature, quasi-static compression test results and the high-temperature hardness test results was built by the development of a high-temperature indentation finite element (FE simulation. The simulated and experimental results of high-temperature hardness have been compared, verifying the accuracy of the high-temperature indentation FE simulation.The simulated results show that the high temperature hardness basically does not change with the change of load when the pile-up of material during indentation is ignored. The simulated and experimental results show that the decrease in hardness and thermal softening are consistent. The strain and stress of indentation were analyzed from the simulated contour. It was found that the strain increases with the increase of the test temperature, and the stress decreases with the increase of the test temperature.

  19. Present status on numerical algorithms and benchmark tests for point kinetics and quasi-static approximate kinetics

    International Nuclear Information System (INIS)

    Ise, Takeharu

    1976-12-01

    Review studies have been made on algorithms of numerical analysis and benchmark tests on point kinetics and quasistatic approximate kinetics computer codes to perform efficiently benchmark tests on space-dependent neutron kinetics codes. Point kinetics methods have now been improved since they can be directly applied to the factorization procedures. Methods based on Pade rational function give numerically stable solutions and methods on matrix-splitting are interested in the fact that they are applicable to the direct integration methods. An improved quasistatic (IQ) approximation is the best and the most practical method; it is numerically shown that the IQ method has a high stability and precision and the computation time which is about one tenth of that of the direct method. IQ method is applicable to thermal reactors as well as fast reactors and especially fitted for fast reactors to which many time steps are necessary. Two-dimensional diffusion kinetics codes are most practicable though there exist also three-dimensional diffusion kinetics code as well as two-dimensional transport kinetics code. On developing a space-dependent kinetics code, in any case, it is desirable to improve the method so as to have a high computing speed for solving static diffusion and transport equations. (auth.)

  20. THE EFFECT OF THE STATIC RELATIVE STRENGTH ON THE MAXIMUM RELATIVE RECEIVING OF OXYGEN

    Directory of Open Access Journals (Sweden)

    Abdulla Elezi

    2011-09-01

    Full Text Available Based on research on the sample of 263 students of age- 18 years, and used batteries of 9 tests for evaluation of the static relative strength and the criterion variable- maximum relative receiving of oxygen (VO2 ml / kg / min based on the Astrand test ,and on regression analysis to determine the influence of the static relative strength on the criterion variable maximum relative oxygen receiving, can be generally concluded that from 9 predictor variables statistically significant partial effect have 2variables. In hierarchical order, they are: the variable of static relative leg strength - endurance of the fingers (the angle of the lower leg and thigh 900 (SRL2 which arithmetic mean is 25.04 seconds and variable ctatic relative strength of arms and shoulders – push-up endurance in the balance beam (angle of the forearm and upper arm 900 ( SRA2 with arithmetic mean of 17.75 seconds. From the statistically influential significant predictor variables on the criterion variable one is from the static relative leg strength (SRL2 and the other is from the static relative strength of arm and shoulder area (SRA2. With the analysis of these relations we can conclude that the isometric contractions of the four headed thigh muscle and the isometric contractions of the three headed upper arm muscle are predominantly responsible for the successful execution of doing actions on a bicycle ergometer and not on the maximum relative receiving of oxygen.

  1. Experimental study on vertical static stiffnesses of polycal wire rope isolators

    Science.gov (United States)

    Balaji, P. S.; Moussa, Leblouba; Khandoker, Noman; Yuk Shyh, Ting; Rahman, M. E.; Hieng Ho, Lau

    2017-07-01

    Wire rope isolator is one of the most effective isolation system that can be used to attenuate the vibration disturbances and shocks during the operation of machineries. This paper presents the results of investigation on static elastic stiffnesses (both in tension and in compression) of Polycal Wire Rope Isolator (PWRI) under quasi-static monotonic loading conditions. It also studied effect of variations in height and width of PWRI on its static stiffnesses. Suitable experimental setup was designed and manufactured to meet the test conditions. The results show that their elastic stiffnesses for both tension and compression loading conditions are highly influenced by their geometric dimensions. It is found that their compressive stiffness reduced by 55% for an increment of 20% in their height to width ratio. Therefore, the stiffness of PWRI can be fine-tuned by controlling their dimensions according to the requirements of the application.

  2. Using the Functional Reach Test for Probing the Static Stability of Bipedal Standing in Humanoid Robots Based on the Passive Motion Paradigm

    Directory of Open Access Journals (Sweden)

    Jacopo Zenzeri

    2013-01-01

    Full Text Available The goal of this paper is to analyze the static stability of a computational architecture, based on the Passive Motion Paradigm, for coordinating the redundant degrees of freedom of a humanoid robot during whole-body reaching movements in bipedal standing. The analysis is based on a simulation study that implements the Functional Reach Test, originally developed for assessing the danger of falling in elderly people. The study is carried out in the YARP environment that allows realistic simulations with the iCub humanoid robot.

  3. Technical study on semi-object emulation of structural statics problem

    CERN Document Server

    MoJun; LiuXingFu; LiuZhiYong; Shi Pin Gan

    2002-01-01

    Structural strength analysis depends mainly on finite element method and experiments. For complex structural system, a rather large error can be caused by some uncertain factors, such as load distributions, boundary conditions and constitutive relations in numerical analysis. At the same time, owing to the limitation of measuring and testing techniques, the strength and stiffness of key components can not be estimated by using the limited test data. To simulate stresses accurately under complex static environment, improve man-machine interactive system, and make the best use of fore- and post-processing function in graphic data processing, the combine numerical analysis with experimental technique and have developed the semi-object emulation technique to analyze the nonlinear problem of structure statics. The modern optical measuring techniques and image processing techniques are firstly used for the method to acquire displacement data of the vessel surface, and the data are used for the boundary condition to...

  4. A PSP-based small-signal MOSFET model for both quasi-static and nonquasi-static operations

    NARCIS (Netherlands)

    Aarts, A.C.T.; Smit, G.D.J.; Scholten, A.J.; Klaassen, D.B.M.

    2008-01-01

    In this paper, a small-signal MOSFET model is described, which takes the local effects of both velocity saturation and transverse mobility reduction into account. The model is based on the PSP model and is valid for both quasi-static and nonquasi-static (NQS) operations. Recently, it has been found

  5. Effects of static strain aging on residual stress stability and alternating bending strength of shot peened AISI 4140

    Energy Technology Data Exchange (ETDEWEB)

    Menig, R.; Schulze, V.; Voehringer, O. [Inst. fuer Werkstoffkunde 1, Univ. Karlsruhe (TH), Karlsruhe (Germany)

    2002-07-01

    Increases of residual stress stability and alternating bending strength of shot peened AISI 4140 are obtained by successive annealing treatments. This is caused by static strain aging effects, which lead to pinning of dislocations by carbon atoms and very small carbides. It will be shown that by well directed annealing of a quenched and tempered AISI 4140 it is possible to maximize the positive effects of static strain aging, without causing extended thermal residual stress relaxation. The amount of yield stress increases caused by static strain aging is quantified using tensile tests. Static strain aging is also found to be responsible for an increase of the quasi static and cyclic surface yield strength present after shot peening. (orig.)

  6. Active design method for the static characteristics of a piezoelectric six-axis force/torque sensor.

    Science.gov (United States)

    Liu, Jun; Li, Min; Qin, Lan; Liu, Jingcheng

    2014-01-02

    To address the bottleneck issues of an elastic-style six-axis force/torque sensor (six-axis force sensor), this work proposes a no-elastic piezoelectric six-axis force sensor. The operating principle of the piezoelectric six-axis force sensor is analyzed, and a structural model is constructed. The static-active design theory of the piezoelectric six-axis force sensor is established, including a static analytical/mathematical model and numerical simulation model (finite element model). A piezoelectric six-axis force sensor experimental prototype is developed according to the analytical mathematical model and numerical simulation model, and selected static characteristic parameters (including sensitivity, isotropic degree and cross-coupling) are tested using this model with three approaches. The measured results are in agreement with the analytical results from the static-active design method. Therefore, this study has successfully established a foundation for further research into the piezoelectric multi-axis force sensor and an overall design approach based on static characteristics.

  7. Evaluation of static and dynamic balance in elderly women performing aquatic exercise and gymnastics

    Directory of Open Access Journals (Sweden)

    Ana Paula Almeida

    2010-01-01

    Full Text Available This study evaluated static and dynamic balance and related motor valences in elderly women who had been undergone gymnastics or aquatic exercise training for at least 6 months, three times a week. Thirty-one women performed water gymnastics (mean age: 69.32 ± 6.57 years and 28 gymnastics (65.57 ± 7.67 years. Height (cm, weight (kg and waist, hip and abdominal circumference (cm were measured and the body mass index (BMI and waist-hip ratio (WHR were calculated. Physical fitness was measured using the “sit and get up in 30 seconds” test (leg endurance and “8-foot up-and-go” test (dynamic balance, both proposed by Rikli and Jones (1999, and the “sit and reach” (flexibility and static balance tests described by Caromano (1998. Statistical analysis was performed using the Student t-test and Pearson’s correlation, with a level of significance of 0.05. No significant difference in the anthropometric measures (BMI and WHR was observed between groups. In the physical fitness tests, significant differences were only found in the “8-foot up-and-go” and “sit and get up” tests, with the gymnastics group presenting better results. No correlations within or between groups were observed regarding static and dynamic balance or motor valences. In conclusion, neither type of exercise was superior but the gymnastics group tended to show better results in terms of parameters such as agility, balance and flexibility.

  8. Collapse mechanisms of metal foam matrix composites under static and dynamic loading conditions

    Energy Technology Data Exchange (ETDEWEB)

    Linul, Emanoil, E-mail: emanoil.linul@upt.ro [Department of Mechanics and Strength of Materials, Politehnica University of Timisoara, 1 Mihai Viteazu Avenue, 300 222 Timisoara (Romania); Marsavina, Liviu [Department of Mechanics and Strength of Materials, Politehnica University of Timisoara, 1 Mihai Viteazu Avenue, 300 222 Timisoara (Romania); Kováčik, Jaroslav [Institute of Materials and Machine Mechanics, Slovak Academy of Sciences, Dúbravská cesta 9, 845 13 Bratislava (Slovakia)

    2017-04-06

    The collapse mechanisms of metal foam matrix composites under static and dynamic loading conditions were experimentally and analytically investigated. Closed-cell aluminium foam AlSi10 with 325±10 kg/m{sup 3} density was used as core material, while stainless-steel-mesh is the faces materials. Prior to characterizing the composite sandwich structure, the stainless steel mesh face material and closed-cell aluminium foam were characterized by tensile testing and compression testing, respectively. Experimental tests were performed on sandwich beams using both High Speed Camera and Digital Image Correlation system for strain distribution. All experimental tests were performed at room temperature with constant crosshead speed of 1.67×10{sup −4} m/s for static tests and 2 m/s impact loading speed for dynamic tests. Two main deformation behaviours of investigated metal foam matrix composites were observed following post-failure collapse: face failure and core shear. It was showed that the initiation, propagation and interaction of failure modes depend on the type of loading, constituent material properties and geometrical parameters.

  9. Relationship Between Elderly Body Composition Indices and Static and Dynamic Balance in Relation to Their Rate of Falling

    Directory of Open Access Journals (Sweden)

    Elham Azimzadeh

    2013-01-01

    Full Text Available Objectives: The purpose of this study was to investigate relationship between body composition indices with static and dynamic balance and rate of falling in active elderly people. Methods & Materials: This research was a correlation study. Active elderly women volunteered for participation in this research (n=45. Body composition indices (body fat mass, fat free mass, body mass index, waist to hip ratio measured with the body composition analyzer. Static and dynamic balance measured by Biodex, with postural stability and fall risk tests, respectively. Also, the rate of falling in the previous 1- year asked for subjects. Statically analyses performed with the Pearson correlation test, significant level was set at P≤0.05. SPSS software was used. Results: The results of this study showed all of body composition indices have significant correlation with static and dynamic balance and rate of falling (P≤0.05. Conclusion: The finding of this research showed that all of body composition indices have significant correlation with static and dynamic balance and rate of falling in active elderly people. Therefore, it seems physical activity through improvement of body composition indices in active elderly people, causes improvement of static and dynamic balance and lowering the rate of falling.

  10. Development of a static feed water electrolysis system

    Science.gov (United States)

    Schubert, F. H.; Lantz, J. B.; Hallick, T. M.

    1982-01-01

    A one person level oxygen generation subsystem was developed and production of the one person oxygen metabolic requirements, 0.82 kg, per day was demonstrated without the need for condenser/separators or electrolyte pumps. During 650 hours of shakedown, design verification, and endurance testing, cell voltages averaged 1.62 V at 206 mA/sq cm and at average operating temperature as low as 326 K, virtually corresponding to the state of the art performance previously established for single cells. This high efficiency and low waste heat generation prevented maintenance of the 339 K design temperature without supplemental heating. Improved water electrolysis cell frames were designed, new injection molds were fabricated, and a series of frames was molded. A modified three fluid pressure controller was developed and a static feed water electrolysis that requires no electrolyte in the static feed compartment was developed and successfully evaluated.

  11. On the relationship between ontogenetic and static allometry.

    Science.gov (United States)

    Pélabon, Christophe; Bolstad, Geir H; Egset, Camilla K; Cheverud, James M; Pavlicev, Mihaela; Rosenqvist, Gunilla

    2013-02-01

    Ontogenetic and static allometries describe how a character changes in size when the size of the organism changes during ontogeny and among individuals measured at the same developmental stage, respectively. Understanding the relationship between these two types of allometry is crucial to understanding the evolution of allometry and, more generally, the evolution of shape. However, the effects of ontogenetic allometry on static allometry remain largely unexplored. Here, we first show analytically how individual variation in ontogenetic allometry and body size affect static allometry. Using two longitudinal data sets on ontogenetic and static allometry, we then estimate variances and covariances for the different parameters of the ontogenetic allometry defined in our model and assess their relative contribution to the static allometric slope. The mean ontogenetic allometry is the main parameter that determines the static allometric slope, while the covariance between the ontogenetic allometric slope and body size generates most of the discrepancies between ontogenetic and static allometry. These results suggest that the apparent evolutionary stasis of the static allometric slope is not generated by internal (developmental) constraints but more likely results from external constraints imposed by selection.

  12. Acceleration of a Static Observer Near the Event Horizon of a Static Isolated Black Hole.

    Science.gov (United States)

    Doughty, Noel A.

    1981-01-01

    Compares the magnitude of the proper acceleration of a static observer in a static, isolated, spherically symmetric space-time region with the Newtonian result including the situation in the interior of a perfect-fluid star. This provides a simple physical interpretation of surface gravity and illustrates the global nature of the event horizon.…

  13. Homotheties of cylindrically symmetric static spacetimes

    International Nuclear Information System (INIS)

    Qadir, A.; Ziad, M.; Sharif, M.

    1998-08-01

    In this note we consider the homotheties of cylindrically symmetric static spacetimes. We find that we can provide a complete list of all metrics that admit non-trivial homothetic motions and are cylindrically symmetric static. (author)

  14. Technical study on semi-object emulation of structural statics problem

    International Nuclear Information System (INIS)

    Mo Jun; Shi Pingan; Liu Xingfu; Liu Zhiyong; Fu Chunyu

    2002-01-01

    Structural strength analysis depends mainly on finite element method and experiments. For complex structural system, a rather large error can be caused by some uncertain factors, such as load distributions, boundary conditions and constitutive relations in numerical analysis. At the same time, owing to the limitation of measuring and testing techniques, the strength and stiffness of key components can not be estimated by using the limited test data. To simulate stresses accurately under complex static environment, improve man-machine interactive system, and make the best use of fore- and post-processing function in graphic data processing, the authors combine numerical analysis with experimental technique and have developed the semi-object emulation technique to analyze the nonlinear problem of structure statics. The modern optical measuring techniques and image processing techniques are firstly used for the method to acquire displacement data of the vessel surface, and the data are used for the boundary condition to determine the geometrical size of disfigurement in the wall of vessel and the stress level. The experimental verification of a given test model show that these adverse problem can be solved by using semi-object emulation technology

  15. Aqueous corrosion in static capsule tests representing multi-metal assemblies in the hydraulic circuit of Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Lipa, M. [Association Euratom-CEA, CEA/DSM/DRFC, Centre de Cadarache, 13108 Saint-Paul-Lez-Durance (France)], E-mail: manfred.lipa@cea.fr; Blanchet, J.; Feron, D. [CEA/DEN/SCCME, Centre de Saclay, 91191 Gif sur Yvette (France); Cellier, F. [AREVA ANP, Centre Technique, 71380 Saint Marcel (France)

    2008-12-15

    Tore supra (TS) in vessel components represent a unique combination of metals in the hydraulic circuit. Different materials, e.g. stainless steel, copper alloys, nickel, etc., were joined together by fusion welding, brazing and friction. Since the operation and baking temperature of all in vessel components has been defined to be set at 230 deg. C/40 bars a special water chemistry of the cooling water loop was suggested in order to prevent eventual water leaks due to corrosion at relative high temperatures and pressures in tubes, bellows, coils and coolant plant ancillary equipments. Following experiences with water chemistry in Pressurised Water Reactors, an all volatile chemical treatment (AVT) has been defined for the cooling water quality of TS. Since then, a simplified static (no fluid circulation) corrosion test program at relatively high temperature and pressure has been performed using capsule-type samples made of above mentioned multi-metal assemblies.

  16. Increased fall risk is associated with elevated co-contraction about the ankle during static balance challenges in older adults.

    Science.gov (United States)

    Nelson-Wong, Erika; Appell, Ryan; McKay, Mike; Nawaz, Hannah; Roth, Joanna; Sigler, Robert; Third, Jacqueline; Walker, Mark

    2012-04-01

    Falls are a leading contributor to disability in older adults. Increased muscle co-contraction in the lower extremities during static and dynamic balance challenges has been associated with aging, and also with a history of falling. Co-contraction during static balance challenges has not been previously linked with performance on clinical tests designed to ascertain fall risk. The purpose of this study was to investigate the relationship between co-contraction about the ankle during static balance challenges with fall risk on a commonly used dynamic balance assessment, the Four Square Step Test (FSST). Twenty-three volunteers (mean age 73 years) performed a series of five static balance challenges (Romberg eyes open/closed, Sharpened Romberg eyes open/closed, and Single Leg Standing) with continuous electromyography (EMG) of bilateral tibialis anterior and gastrocnemius muscles. Participants then completed the FSST and were categorized as 'at-risk' or 'not-at-risk' to fall based on a cutoff time of 12 s. Co-contraction was quantified with co-contraction index (CCI). CCI during narrow base conditions was positively correlated with time to complete FSST. High CCIs during all static balance challenges with the exception of Romberg stance with eyes closed were predictive of being at-risk to fall based on FSST time, odds ratio 19.3. The authors conclude that co-contraction about the ankle during static balance challenges can be predictive of performance on a dynamic balance test.

  17. Optical characterisation of 3-D static solar concentrator

    International Nuclear Information System (INIS)

    Sellami, Nazmi; Mallick, Tapas K.; McNeil, David A.

    2012-01-01

    Highlights: ► A novel static solar concentrator was designed coined the Square Elliptical Hyperboloid, SEH. ► The geometrical profile of the SEH was optimised for a low concentration ratio of 4 suns. ► The SEH has a large acceptance angle of 120° allowing 8 h of sun collection during the day. ► A prototype of the SEH was made and tested in indoors conditions. ► The experimental results validate the optical model. - Abstract: The focus of this research is to develop a solar concentrator which is compact, static and, at the same time, able to collect maximum solar energy. A novel geometry of a 3-D static concentrator has been designed and coined the Square Elliptical Hyperboloid (SEH) to be integrated in glazing windows or facades for photovoltaic application. The 4× SEH is optically optimised for different incident angles of the incoming light rays. The optimised SEH is obtained by investigating its different non-dimensional parameters such as major axis over minor axis of the elliptical entry and the height over side of the exit aperture. Evaluating the best combination of the optical efficiency and the acceptance angle, results confirm that the 4× SEH built from dielectric material, working with total internal reflection, is found to have a constant optical efficiency of 40% for an acceptance angle equal to 120° (−60°, +60°). This enables capture of the sun rays all day long from both direct beam light and diffuse light making it highly suitable for use in northern European countries. A higher optical efficiency of 70% is obtained for different dimensions of the SEH; however, the acceptance angle is only 50°. The optimised SEH concentrator has been manufactured and tested; the experimental results show an agreement with the simulation results thus validating the optical model.

  18. Static leaching of uraniferous shales with countercurrent circuits

    International Nuclear Information System (INIS)

    Cordero, G.; Villarrubia, M.; Hernandez, J.

    1973-01-01

    We test different amounts of acid and the way of adding it in order to obtain the solubilization of uranium in static leaching. We also test the effects of the temperature. Finally we show the tests of solvent extraction considering the most important variables in it . In leaching we must work with 32 kg/t of acid and 40 d in order to obtain uraniums solubilization over 80%, The pregnant liquors have a high concentration of silica and we must use low organic liquid ( ≤ 3,5 % in amine) and fit the acidity of the pregnant Solutions to 4-8 g H 2 SO 4 /I. We show the economy of the process. (Author)

  19. Metal magnetic memory effect caused by static tension load in a case-hardened steel

    International Nuclear Information System (INIS)

    Shi, C.L.; Dong, S.Y.; Xu, B.S.; He, P.

    2010-01-01

    For investigating the magnetic abnormality influenced by stress in ferromagnetic materials, static tension tests on a case-hardened steel were carried out. Different loads, which covered tensile elastic loads up to plastic deformation and break, were applied. Meanwhile, the normal component of magnetic flux leakage, H p (y), was measured by metal magnetic memory testing. The results indicate that H p (y) values change with the tensile loads and positions. There exists a relationship between k, which is the inclination of the linear amplitude-locus magnetic flux leakage curve, and static tension load. A simple model is derived. Additionally, the mechanism of the magnetic memory effect can be explained by the theory of the interaction between dislocations and domains. The research provides the potential possibility of quantitative inspection for metal magnetic memory testing.

  20. Effect of dental tool surface texture and material on static friction with a wet gloved fingertip.

    Science.gov (United States)

    Laroche, Charles; Barr, Alan; Dong, Hui; Rempel, David

    2007-01-01

    Hand injuries are an important cause of pain and disability among dentists and dental hygienists and may be due to the high pinch forces involved in periodontal work. The pinch forces required to perform scaling may be reduced by increasing the friction between the tool and fingers. The purpose of this study was to determine whether modifying the tool material, surface texture, or glove type altered the coefficient of static friction for a wet gloved finger. Seven tools with varying surface topography were machined from 13 mm diameter stainless steel and Delrin and mounted to a 6-component force plate. The textures tested were a fine, medium and coarse diamond knurled pattern and a medium and fine annular pattern (concentric rings). Thirteen subjects pulled their gloved, wet thumb pad along the long axis of the tool while maintaining a normal force of 40 N. Latex and nitrile gloves were tested. The coefficient of static friction was calculated from the shear force history. The mean coefficients of static friction ranged from 0.20 to 0.65. The coefficient of static friction was higher for a smooth tool of Delrin than one of stainless steel. Differences in the coefficient of static friction were observed between the coarse and medium knurled patterns and the fine knurled and annular patterns. Coefficients of static friction were higher for the nitrile glove than the latex glove for tools with texture. These findings may be applied to the design of hand tools that require fine motor control with a wet, gloved hand.

  1. Effects of quadriceps strength after static and dynamic whole-body vibration exercise.

    Science.gov (United States)

    Bush, Jill A; Blog, Gabriel L; Kang, Jie; Faigenbaum, Avery D; Ratamess, Nicholas A

    2015-05-01

    Numerous studies have shown performance benefits including whole-body vibration (WBV) as a training modality or an acute exercise protocol when used as a component of the resistance training program. Some studies have indicated that performing dynamic exercises as compared with static position exercises while exposed to WBV might be beneficial; however, evidence is lacking. Thus, the purpose of this study was to determine if an acute bout of dynamic versus static squats performed during WBV results in increase in quadriceps force production by means of dynamic isokinetic knee extension and flexion exercise. Nonresistance-trained healthy young men and women (N = 21) of 18-25 years participated in 4 protocols with 2-week rest in-between. Protocol 1 consisted of 5 sets of 10 dynamic squats without vibration; Protocol 2: 5 sets of 30-second static squats without vibration; Protocol 3: 5 sets of 10 dynamic squats with 30-Hz WBV for a total of 2.5 minutes; and Protocol 4: 5 sets of 30-second static squats with 30-Hz WBV for a total of 2.5 minutes. Prestrength tests (1 set of 4 repetitions at 100° · s(-1) for the knee extension exercise) was performed within 5 minutes of starting each protocol, and poststrength testing was performed within 1 minute of completing each protocol. Strength outcomes were analyzed by repeated measures analysis of variance with a significance level set at p ≤ 0.05. A significant decrease in strength was observed after dynamic and static squats without WBV (p = 0.002); an increase in strength after dynamic squats with WBV (p = 0.003); and a decrease in strength after static squats with WBV (p = 0.003). The inclusion of WBV to dynamic resistance exercise can be an added modality to increase strength. Whole-body vibration can have varied effects in altering muscle strength in untrained individuals according to the type of resistance training performed. As a dynamic squat with WBV seems to immediately potentiate neuromuscular functioning, the

  2. Empirical Tests and Preliminary Results with the Krakatoa Tool for Full Static Program Verification

    Directory of Open Access Journals (Sweden)

    Ramírez-de León Edgar Darío

    2014-10-01

    Full Text Available XJML (Ramírez et al., 2012 is a modular external platform for Verification and Validation of Java classes using the Java Modeling Language (JML through contracts written in XML. One problem faced in the XJML development was how to integrate Full Static Program Verification (FSPV. This paper presents the experiments and results that allowed us to define what tool to embed in XJML to execute FSPV.

  3. Motor starting a Brayton cycle power conversion system using a static inverter

    Science.gov (United States)

    Curreri, J. S.; Edkin, R. A.; Kruchowy, R.

    1973-01-01

    The power conversion module of a 2- to 15-kWe Brayton engine was motor started using a three-phase, 400-hertz static inverter as the power source. Motor-static tests were conducted for initial gas loop pressures of 10, 14, and 17 N/sq cm (15, 20, and 25 psia) over a range of initial turbine inlet temperatures from 366 to 550 K (200 to 530 F). The data are presented to show the effects of temperature and pressure on the motor-start characteristics of the rotating unit. Electrical characteristics during motoring are also discussed.

  4. Seismic performance evaluation of an infilled rocking wall frame structure through quasi-static cyclic testing

    Science.gov (United States)

    Pan, Peng; Wu, Shoujun; Wang, Haishen; Nie, Xin

    2018-04-01

    Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism. This damage mode results in poor ductility and limited energy dissipation. Continuous components offer alternatives that may avoid such failures. A novel infilled rocking wall frame system is proposed that takes advantage of continuous component and rocking characteristics. Previous studies have investigated similar systems that combine a reinforced concrete frame and a wall with rocking behavior used. However, a large-scale experimental study of a reinforced concrete frame combined with a rocking wall has not been reported. In this study, a seismic performance evaluation of the newly proposed infilled rocking wall frame structure was conducted through quasi-static cyclic testing. Critical joints were designed and verified. Numerical models were established and calibrated to estimate frame shear forces. The results evaluation demonstrate that an infilled rocking wall frame can effectively avoid soft-story mechanisms. Capacity and initial stiffness are greatly improved and self-centering behavior is achieved with the help of the infilled rocking wall. Drift distribution becomes more uniform with height. Concrete cracks and damage occurs in desired areas. The infilled rocking wall frame offers a promising approach to achieving seismic resilience.

  5. A GPS-Based Pitot-Static Calibration Method Using Global Output-Error Optimization

    Science.gov (United States)

    Foster, John V.; Cunningham, Kevin

    2010-01-01

    Pressure-based airspeed and altitude measurements for aircraft typically require calibration of the installed system to account for pressure sensing errors such as those due to local flow field effects. In some cases, calibration is used to meet requirements such as those specified in Federal Aviation Regulation Part 25. Several methods are used for in-flight pitot-static calibration including tower fly-by, pacer aircraft, and trailing cone methods. In the 1990 s, the introduction of satellite-based positioning systems to the civilian market enabled new inflight calibration methods based on accurate ground speed measurements provided by Global Positioning Systems (GPS). Use of GPS for airspeed calibration has many advantages such as accuracy, ease of portability (e.g. hand-held) and the flexibility of operating in airspace without the limitations of test range boundaries or ground telemetry support. The current research was motivated by the need for a rapid and statistically accurate method for in-flight calibration of pitot-static systems for remotely piloted, dynamically-scaled research aircraft. Current calibration methods were deemed not practical for this application because of confined test range size and limited flight time available for each sortie. A method was developed that uses high data rate measurements of static and total pressure, and GPSbased ground speed measurements to compute the pressure errors over a range of airspeed. The novel application of this approach is the use of system identification methods that rapidly compute optimal pressure error models with defined confidence intervals in nearreal time. This method has been demonstrated in flight tests and has shown 2- bounds of approximately 0.2 kts with an order of magnitude reduction in test time over other methods. As part of this experiment, a unique database of wind measurements was acquired concurrently with the flight experiments, for the purpose of experimental validation of the

  6. Static Einstein--Maxwell field equations

    International Nuclear Information System (INIS)

    Das, A.

    1979-01-01

    The static Einstein--Maxwell field equations are investigated in the presence of both electric and magnetic fields. The sources or bodies are assumed to be of finite size and to not affect the connectivity of the associated space. Furthermore, electromagnetic and metric fields are assumed to have reasonable differentiabilities. It is then proved that the electric and magnetic field vectors are constant multiples of one another. Moreover, the static Einstein--Maxwell equations reduce to the static magnetovac case. If, furthermore, the variational derivation of the Einstein--Maxwell equations is assumed, then both the total electric and magnetic charge of each body must vanish. As a physical consequence it is pointed out that if a suspended magnet be electrically charged then it must experience a purely general relativistic torque

  7. Mental, Physical and Mixed Practice Effects on Elderly Static and Dynamic Balance

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Aslankhani

    2008-10-01

    Full Text Available Objectives: After age of 65, annually 10 percent of older adults> loss their independent in one or more daily task. Because of decreasing changes in neuromuscular system that is important factor in loss the balance and walking ability in this group of people. In according to these sentences, the aim of this research was to the comparison of mental, physical and mixed practices on static and dynamic balance in health older adults. Methods & Materials: The study is semi-experimental with pre and post test design and three experimental groups. Statistical sample included 60 older adults> with age range of 60-70 years from Shahre-kord, that randomly divided to three experimental groups. In this research, the Stroke stands test (standing with one leg were used to measure the static balance and Star Excursion Balance Test (SEBT test was used to measure the dynamic balance. After 8 session of training, subject of each group participated in post test that similar to pretest. The data were analyzed by one way ANOVA and Tukey post hoc and in order to detect the homogeny of variances, Leaven>s test was used in level of P balance by strength training, coaches and related affairs can use this training method in their specific programs for older adults.

  8. 'Static' octupole deformation

    International Nuclear Information System (INIS)

    Leander, G.A.

    1985-01-01

    Certain nuclei can be described as having intrinsic shapes with parity breaking static moments. The rationale for this description is discussed, spectroscopic models are outlined and their consequences are compared with experiment. (orig.)

  9. Static Analysis of Mobile Programs

    Science.gov (United States)

    2017-02-01

    and not allowed, to do. The second issue was that a fully static analysis was never a realistic possibility, because Java , the programming langauge...scale to large programs it had to handle essentially all of the features of Java and could also be used as a general-purpose analysis engine. The...static analysis of imperative languages. • A framework for adding specifications about the behavior of methods, including methods that were

  10. Static Decoupling in fault detection

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik

    1998-01-01

    An algebraic approach is given for a design of a static residual weighting factor in connection with fault detection. A complete parameterization is given of the weighting factor which will minimize a given performance index......An algebraic approach is given for a design of a static residual weighting factor in connection with fault detection. A complete parameterization is given of the weighting factor which will minimize a given performance index...

  11. Comparison of static friction with self-ligating, modified slot design and conventional brackets.

    Science.gov (United States)

    Castro, Raquel Morais; Neto, Perrin Smith; Horta, Martinho Campolina Rebello; Pithon, Matheus Melo; Oliveira, Dauro Douglas

    2013-01-01

    To compare the static frictional forces generated at the bracket/wire interface of stainless steel brackets with different geometries and angulations, combined with orthodontic wires of different diameters. The frictional forces were evaluated with three different types of metal brackets: a passive self-ligating (SmartClipTM, 3M/Unitek, Monrovia, USA), with a modified slot design (Mini Uni TwinTM, 3M/Unitek, Monrovia, USA) and conventional (Kirium, Abzil, São José do Rio Preto, Brazil). The samples were mounted in a testing device with three different angulations and tested with 0.014" and 0.018" stainless steel wires (American Orthodontics, Sheboygan, USA). The static frictional force was measured using a universal testing machine (DL 500, EMIC®, São José dos Pinhais, Brazil) with a crosshead speed of 1 mm/min. Statistical analysis was performed by two-way ANOVA followed by Bonferroni's post hoc test. There was a significant difference (pstatic friction when the three types of brackets were tested with the same wire size. The wire diameter influenced friction only when the brackets had a 10º angulation (pfriction (pstatic frictional force values between the conventional and self-ligating brackets tested.

  12. Rock Physical Interpretation of the Relationship between Dynamic and Static Young's Moduli of Sedimentary Rocks

    Science.gov (United States)

    Takahashi, T.

    2017-12-01

    The static Young's modulus (deformability) of a rock is indispensable for designing and constructing tunnels, dams and underground caverns in civil engineering. Static Young's modulus which is an elastic modulus at large strain level is usually obtained with the laboratory tests of rock cores sampled in boreholes drilled in a rock mass. A deformability model of the entire rock mass is then built by extrapolating the measurements based on a rock mass classification obtained in geological site characterization. However, model-building using data obtained from a limited number of boreholes in the rock mass, especially a complex rock mass, may cause problems in the accuracy and reliability of the model. On the other hand, dynamic Young's modulus which is the modulus at small strain level can be obtained from seismic velocity. If dynamic Young's modulus can be rationally converted to static one, a seismic velocity model by the seismic method can be effectively used to build a deformability model of the rock mass. In this study, we have, therefore, developed a rock physics model (Mavko et al., 2009) to estimate static Young's modulus from dynamic one for sedimentary rocks. The rock physics model has been generally applied to seismic properties at small strain level. In the proposed model, however, the sandy shale model, one of rock physics models, is extended for modeling the static Young's modulus at large strain level by incorporating the mixture of frictional and frictionless grain contacts into the Hertz-Mindlin model. The proposed model is verified through its application to the dynamic Young's moduli derived from well log velocities and static Young's moduli measured in the tri-axial compression tests of rock cores sampled in the same borehole as the logs were acquired. This application proves that the proposed rock physics model can be possibly used to estimate static Young's modulus (deformability) which is required in many types of civil engineering applications

  13. Strategy for Alternative Occupant Volume Testing

    Science.gov (United States)

    2009-10-20

    This paper describes plans for a series of quasi-static : compression tests of rail passenger equipment. These tests are : designed to evaluate the strength of the occupant volume under : static loading conditions. The research plan includes a detail...

  14. On the scaling of gas leakage from static seals

    International Nuclear Information System (INIS)

    Chivers, T.C.; Hunt, R.P.

    1977-01-01

    The interaction between gas leakage from static seals and eight potential variables is discussed. From a consideration of the interaction of these various parameters and the mechanical design of the seal system the importance of correctly interpreting leakage data is demonstrated. Given a situation where model experiments are necessary, this document forms a basis for the definition and interpretation of a test programme. (author)

  15. Generalization of the memory integer model for the analysis of the quasi-static behaviour of polyurethane foams

    International Nuclear Information System (INIS)

    Jmal, Hamdi; Ju, Ming Lei; Dupuis, Raphael; Aubry, Evelyne

    2014-01-01

    Polyurethane foam is a cellular material characterized by an interesting mechanical spectrum of properties: low density, capacity to absorb the deformation energy and low stiffness. This spectrum of properties makes polyurethane foam commonly used in many thermal, acoustic and comfort applications. Several models, such as memory, hyper-elastic and pseudo-elastic models have been developed in the literature to describe the mechanical response of polyurethane foam under quasi-static and dynamic test conditions. The main disadvantage of these models is the dependence of their parameters against the test conditions (strain rate, maximum compression level, etc). This affects the general character of their representativeness to the quasi-static and dynamic behaviours of polyurethane foam. The main goal of this article is to implement reliable mechanical model which is able to provide the quasi-static response of the polyurethane foam under different strain rates and large compressive deformation. The dimensional parameters of our model can be expressed by the product of two independent parts; the first contain only the test conditions and the second define the dimensionless and invariant parameters that characterize the foam material. The developed model has been proposed after several experimental studies allowing the apprehension of the quasi-static behaviour (through unidirectional compression tests). The polyurethane foam, under large deformations, exhibits a nonlinear elastic behaviour and viscoelastic behaviour. To assess the ability of our model to be a general representation, three industrial polyurethane foams have been considered.

  16. Triaxial quasi-static compression and creep behavior of bedded salt from southeastern New Mexico

    International Nuclear Information System (INIS)

    Hansen, F.D.

    1979-11-01

    This report summarizes the results obtained from a series of triaxial quasi-static compression and creep tests on specimens of bedded salt recovered at depth intervals of 1953 to 1954 and 2711 to 2722 feet in AEC Hole No. 7 in southeastern New Mexico. The primary objective was the determination of the deformational characteristics of the salt for prescribed stress and temperature states under quasi-static and time-dependent conditions. The test conditions encompassed confining pressures of 500 and 2000 psi, differential axial stresses of 1500, 3000 and 4500 psi, temperatures of 23 and 100 0 C, and time durations of several hours to ten days. The data analysis was confined primarily to power law fits to the creep strain-time measurements and to an evaluation of the principal strain ratio behavior for the various test conditions and axial strain magnitudes

  17. Dynamic testing in schizophrenia: does training change the construct validity of a test?

    Science.gov (United States)

    Wiedl, Karl H; Schöttke, Henning; Green, Michael F; Nuechterlein, Keith H

    2004-01-01

    Dynamic testing typically involves specific interventions for a test to assess the extent to which test performance can be modified, beyond level of baseline (static) performance. This study used a dynamic version of the Wisconsin Card Sorting Test (WCST) that is based on cognitive remediation techniques within a test-training-test procedure. From results of previous studies with schizophrenia patients, we concluded that the dynamic and static versions of the WCST should have different construct validity. This hypothesis was tested by examining the patterns of correlations with measures of executive functioning, secondary verbal memory, and verbal intelligence. Results demonstrated a specific construct validity of WCST dynamic (i.e., posttest) scores as an index of problem solving (Tower of Hanoi) and secondary verbal memory and learning (Auditory Verbal Learning Test), whereas the impact of general verbal capacity and selective attention (Verbal IQ, Stroop Test) was reduced. It is concluded that the construct validity of the test changes with dynamic administration and that this difference helps to explain why the dynamic version of the WCST predicts functional outcome better than the static version.

  18. Thermal effects in static friction: thermolubricity.

    Science.gov (United States)

    Franchini, A; Bortolani, V; Santoro, G; Brigazzi, M

    2008-10-01

    We present a molecular dynamics analysis of the static friction between two thick slabs. The upper block is formed by N2 molecules and the lower block by Pb atoms. We study the effects of the temperature as well as the effects produced by the structure of the surface of the lower block on the static friction. To put in evidence the temperature effects we will compare the results obtained with the lower block formed by still atoms with those obtained when the atoms are allowed to vibrate (e.g., with phonons). To investigate the importance of the geometry of the surface of the lower block we apply the external force in different directions, with respect to a chosen crystallographic direction of the substrate. We show that the interaction between the lattice dynamics of the two blocks is responsible for the strong dependence of the static friction on the temperature. The lattice dynamics interaction between the two blocks strongly reduces the static friction, with respect to the case of the rigid substrate. This is due to the large momentum transfer between atoms and the N2 molecules which disorders the molecules of the interface layer. A further disorder is introduced by the temperature. We perform calculations at T = 20K which is a temperature below the melting, which for our slab is at 50K . We found that because of the disorder the static friction becomes independent of the direction of the external applied force. The very low value of the static friction seems to indicate that we are in a regime of thermolubricity similar to that observed in dynamical friction.

  19. Static Analysis for JavaScript

    DEFF Research Database (Denmark)

    Jensen, Simon Holm

    . This dissertation describes the design and implementation of a static analysis for JavaScript that can assist programmers in finding bugs in code during development. We describe the design of a static analysis tool for JavaScript, built using the monotone framework. This analysis infers detailed type information......Web applications present unique challenges to designers of static analysis tools. One of these challenges is the language JavaScript used for client side scripting in the browser. JavaScript is a complex language with many pitfalls and poor tool support compared to other languages...... about programs. This information can be used to detect bugs such as null pointer dereferences and unintended type coercions. The analysis is sound, enabling it to prove the absence of certain program errors. JavaScript is usually run within the context of the browser and the DOM API. The major...

  20. Evaluating web-based static, animated and interactive maps for injury prevention

    Directory of Open Access Journals (Sweden)

    Jonathan Cinnamon

    2009-11-01

    Full Text Available Public health planning can benefit from visual exploration and analysis of geospatial data. Maps and geovisualization tools must be developed with the user-group in mind. User-needs assessment and usability testing are crucial elements in the iterative process of map design and implementation. This study presents the results of a usability test of static, animated and interactive maps of injury rates and socio-demographic determinants of injury by a sample of potential end-users in Toronto, Canada. The results of the user-testing suggest that different map types are useful for different purposes and for satisfying the varying skill level of the individual user. The static maps were deemed to be easy to use and versatile, while the animated maps could be made more useful if animation controls were provided. The split-screen concept of the interactive maps was highlighted as particularly effective for map comparison. Overall, interactive maps were identified as the preferred map type for comparing patterns of injury and related socio-demographic risk factors. Information collected from the user-tests is being used to expand and refine the injury web maps for Toronto, and could inform other public health-related geo-visualization projects.

  1. Modeling of static characteristics of switched reluctance motor

    International Nuclear Information System (INIS)

    Asgharmemon, A.; Hussain, I.; Daudpoto, J.

    2013-01-01

    To investigate the running characteristics of a switched reluctance motor, the static characteristics and related input data tables are required. The static characteristics comprise of flux linkage, co-energy and static torque characteristics. The co-energy and static torque are calculated once data of magnetization characteristics is available. The data of co-energy is required for the calculation of static torque characteristics. The simulation model includes the data of static characteristics for prediction of the instantaneous and steady state performance of the motor. In this research a computer based procedure of experiments is carried out for measurement of the magnetization characteristics. For every set of measurements, the removal of eddy current is carefully addressed. The experiments are carried out on an existing 8/6 pole rotary switched reluctance motor. Additionally, the instantaneous phase current, instantaneous torque and flux waveforms are produced by using linear, which is by default and spline data interpolation separately. The information obtained from theses simulation results will help in an improved simulation model for predicting the performance of the machine. (author)

  2. Influence of the void ratio and the confining on the static liquefaction in slopes in shangi sand

    Directory of Open Access Journals (Sweden)

    Alfonso Mariano Ramos Cañón

    2015-01-01

    Full Text Available A numerical study on the onset of static liquefaction in slopes under undrained conditions of loading was developed based on a general liquefaction flow instability criterion for elastoplastic soils based on the concept of loss of controllability. The criterion is applied to the case of axisymmetric loading to detect the onset of static liquefaction. The criterion is used in conjunction with an elastoplastic model for sands and is tested by means of numerical simulations of element tests. The numerical results are compared with experimental evidence obtaining good agreement. A quantitative study of the influence of the mean pressure, void ratio and the anisotropy of stress on the onset of static liquefaction is presented for the Changi sand. From the analysis of the numerical results, it can be concluded that: a. the mobilized friction angle at the onset of liquefaction is not an intrinsic property of the material, but is a state variable b. Despite of the multiple variables involved in the process of generation of undrained instability, the state of stresses at the onset of static liquefaction can be conveniently represented by a linear relation between Dq/po and no . This graphical representation can be used in the practice of geotechnical engineering to quantify the margin of security against the static liquefaction of a sandy slope.

  3. When static media promote active learning: annotated illustrations versus narrated animations in multimedia instruction.

    Science.gov (United States)

    Mayer, Richard E; Hegarty, Mary; Mayer, Sarah; Campbell, Julie

    2005-12-01

    In 4 experiments, students received a lesson consisting of computer-based animation and narration or a lesson consisting of paper-based static diagrams and text. The lessons used the same words and graphics in the paper-based and computer-based versions to explain the process of lightning formation (Experiment 1), how a toilet tank works (Experiment 2), how ocean waves work (Experiment 3), and how a car's braking system works (Experiment 4). On subsequent retention and transfer tests, the paper group performed significantly better than the computer group on 4 of 8 comparisons, and there was no significant difference on the rest. These results support the static media hypothesis, in which static illustrations with printed text reduce extraneous processing and promote germane processing as compared with narrated animations.

  4. Static Balance of Visually Impaired Athletes in Open and Closed Skill Sports

    Directory of Open Access Journals (Sweden)

    Bednarczuk Grzegorz

    2017-03-01

    Full Text Available Introduction. In elite sport, athletes are required to maintain appropriate body posture control despite a number of destabilising factors. The functions of body posture control are monitored by the central nervous system that constantly receives information from the vestibular and somatosensory systems as well as from the visual analyser. Visual impairment may contribute to a decrease in the level of motor abilities and skills; however, it does not prevent visually impaired individuals from taking up physical activity. Therefore, this study sought to assess the static balance of visually impaired goalball players and shooters. Material and methods. The study included 37 goalball players and 20 shooters. A force platform was used to assess static balance. The study participants performed tests: standing on both feet with eyes open (BFEO and closed (BFEC (30 s, single left- and right-leg stance with eyes open (SLEO and SREO as well as single left- and right-leg stance with eyes closed (SLEC and SREC. Statistical analyses were carried out using the following parameters: centre of pressure (CoP path length [cm], CoP velocity [m/s], and the surface area of the stabilogram [cm2]. Results. No significant differences were found between goalball players and shooters in static balance levels. However, such differences were observed after taking into account the number of athletes who were capable of performing particular tests. Conclusions. The findings indirectly confirm that there is a correlation between the type of physical activity and balance levels in visually impaired individuals. Further research ought to include tests performed on an unstable surface.

  5. Acute effect of static stretching on muscle force in older women

    Directory of Open Access Journals (Sweden)

    André Luiz Demantova Gurjão

    2010-04-01

    Full Text Available The objective of this study was to investigate the acute effect of static stretching on the peak rate of force development (PRFD and maximum voluntary contraction (MVC in older women. Ten women (68.5 ± 7.0 years; 70.9 ± 8.1 kg; 159.4 ± 6.0 cm; body mass index: 28.0 ± 3.8 kg/m2 were studied. MVC and PRFD were determined by leg press exercise before and after the control or stretching condition (three sets of 30 seconds of static stretching of the quadriceps on two different days (interval of 24 hours. PRFD was determined as the steepest slope of the curve, calculated within regular windows of 20 milliseconds (∆force/∆time for the first 200 milliseconds after the onset of contraction. MVC was determined as the highest value recorded in each set. Only one condition was tested on each day and the order of application of each condition was determined randomly. The stretching intensity was evaluated by the muscle pain threshold. Four post-condition assessments (post-treatment, 10, 20, and 30 minutes were performed to monitor muscle strength. ANCOVA 2x5, followed by the Scheffé post-hoc test, showed no significant interactions between conditions vs. times (P > 0.05 for PRFD or MVC. In conclusion, acute bouts of static stretching of the quadriceps femoris do not affect the ability of rapid and maximum muscle force production in older women.

  6. Experimental study on swelling character of statics-compacted bentonite-sand mixture

    International Nuclear Information System (INIS)

    Cui Suli; Zhang Huyuan; Liu Jisheng; Liang Jian

    2010-01-01

    In the high-level radioactive waste (HLW) geological disposal projects barrier system, there are two types for constructing buffer/backfill material in preconceived: locale field-pressed and locale-build by prefab lock. Statics-Compacted is needed for both footrill padding in the locale field-pressed and locale-build by prefab lock. Laboratory tests were conducted on statics-compacted mixture of GMZ001 bentonite and quartz sand in different addition. The results obtained indicated that in the semi-log coordinates, the form of the P-time and e-time curves were sigmoid,the same as dynamic-compacted specime. The swelling character of statics-compacted specime were also as well as dynamic-compacted specime, that is with the increase of initial dry density, the maximum swelling pressure were exponential increase and maximum swelling strain increase linearly. These made it clear that the methods of making specime have no effect on the swelling character of bentonite-sand mixture, so methods for constructing buffer/backfill material can be selected free as needed in the construction site. The validity of regression relationship received by dynamic-compacted specime test was verified, and the coefficients for the regression equation were revised in a greater range of initial dry density. Based on the comprehensive analysis of experimental results, it is concluded that addition of 10-30% quartz sand and 1.60-1.80 g/cm 3 for initial dry density to GMZ001 bentonite-sand mixture is suitable for the swelling quality. (authors)

  7. Static, dynamic balance and functional performance in subjects with and without plantar fasciitis

    Directory of Open Access Journals (Sweden)

    Geiseane Aguiar Gonçalves

    Full Text Available Abstract Introduction: Plantar fasciitis (PF is characterized by non-inflammatory degeneration and pain under the heel, and is one of the most common foot complaints. The compensations and adjustments made to decrease the discomfort caused by the disease are clinical findings and can be a factor that contributes to impaired balance and decreased functional performance. Objective: To compare functional performance as well as static and dynamic balance among subjects with and without PF. Methods: The sample consisted of 124 subjects of both sexes aged 20-60 years. Participants were divided into two groups: a bilateral PF group (PFG; n = 62 and a control group (CG, n = 62. The following outcomes were analyzed: static and dynamic balance (using functional tests and functional performance (using a questionnaire. We used Student’s t test for independent samples to compare variables between the groups. The alpha error was set at 0.05. Results: Subjects with PF showed greater impairment in their overall dynamic balance performance (p < 0.001 than the control group, except for left posteromedial movement (p = 0.19. The CG showed showed better functional performance (p < 0.001 than the PF group. There was no difference between groups for the variable static balance on stable (p = 0.160 and unstable surfaces (p = 0.085. Conclusion: Subjects with PF displayed smaller reach distances in the overall Star Excursion Balance Test (SEBT, demonstrating a deficit in dynamic balance and functional performance when compared with healthy subjects.

  8. An analytical study on the static vertical stiffness of wire rope isolators

    Energy Technology Data Exchange (ETDEWEB)

    Balaji, P. S.; Rahman, M. E.; Ho, Lau Hieng [Curtin University Sarawak, Miri (Malaysia); Moussa, Leblouba [University of Sharjah, Sharjah (United Arab Emirates)

    2016-01-15

    The vibrations caused by earthquake ground motions or the operations of heavy machineries can affect the functionality of equipment and cause damages to the hosting structures and surrounding equipment. A Wire rope isolator (WRI), which is a type of passive isolator known to be effective in isolating shocks and vibrations, can be used for vibration isolation of lightweight structures and equipment. The primary advantage of the WRI is that it can provide isolation in all three planes and in any orientation. The load-supporting capability of the WRI is identified from the static stiffness in the loading direction. Static stiffness mainly depends on the geometrical and material properties of the WRI. This study develops an analytical model for the static stiffness in the vertical direction by using Castigliano's second theorem. The model is validated by using the experimental results obtained from a series of monotonic loading tests. The flexural rigidity of the wire ropes required in the model is obtained from the transverse bending test. Then, the analytical model is used to conduct a parametric analysis on the effects of wire rope diameter, width, height, and number of turns (loops) on vertical stiffness. The wire rope diameter influences stiffness more than the other geometric parameters. The developed model can be accurately used for the evaluation and design of WRIs.

  9. Comparison of Numerical Analyses with a Static Load Test of a Continuous Flight Auger Pile

    Science.gov (United States)

    Hoľko, Michal; Stacho, Jakub

    2014-12-01

    The article deals with numerical analyses of a Continuous Flight Auger (CFA) pile. The analyses include a comparison of calculated and measured load-settlement curves as well as a comparison of the load distribution over a pile's length. The numerical analyses were executed using two types of software, i.e., Ansys and Plaxis, which are based on FEM calculations. Both types of software are different from each other in the way they create numerical models, model the interface between the pile and soil, and use constitutive material models. The analyses have been prepared in the form of a parametric study, where the method of modelling the interface and the material models of the soil are compared and analysed. Our analyses show that both types of software permit the modelling of pile foundations. The Plaxis software uses advanced material models as well as the modelling of the impact of groundwater or overconsolidation. The load-settlement curve calculated using Plaxis is equal to the results of a static load test with a more than 95 % degree of accuracy. In comparison, the load-settlement curve calculated using Ansys allows for the obtaining of only an approximate estimate, but the software allows for the common modelling of large structure systems together with a foundation system.

  10. Effect of Hydrotherapy on Static and Dynamic Balance in Older Adults: Comparison of Perturbed and Non-Perturbed Programs

    Directory of Open Access Journals (Sweden)

    Elham Azimzadeh

    2013-01-01

    Full Text Available Objectives: Falling is a main cause of mortality in elderly. Balance training exercises can help to prevent falls in older adults. According to the principle of specificity of training, the perturbation-based trainings are more similar to the real world. So these training programs can improve balance in elderly. Furthermore, exercising in an aquatic environment can reduce the limitations for balance training rather than a non-aquatic on. The aim of this study is comparing the effectiveness of perturbed and non-perturbed balance training programs in water on static and dynamic balance in aforementioned population group. Methods & Materials: 37 old women (age 80-65, were randomized to the following groups: perturbation-based training (n=12, non-perturbation-based training (n=12 and control (n=13 groups. Static and dynamic balance had been tested before and after the eight weeks of training by the postural stability test of the Biodex balance system using dynamic (level 4 and static platform. The data were analyzed by one sample paired t-test, Independent t-test and ANOVA. Results: There was a significant improvement for all indexes of static and dynamic balance in perturbation-based training (P<0.05. However, in non-perturbed group, all indexes were improved except ML (P<0.05. ANOVA showed that perturbed training was more effective than non-perturbed training on both static and dynamic balances. Conclusion: The findings confirmed the specificity principle of training. Although balance training can improve balance abilities, these kinds of trainings are not such specific for improving balance neuromuscular activities.The perturbation-based trainings can activate postural compensatory responses and reduce falling risk. According to results, we can conclude that hydrotherapy especially with perturbation-based programs will be useful for rehabilitation interventions in elderly .

  11. Statics of historic masonry constructions

    CERN Document Server

    Como, Mario

    2017-01-01

    Masonry constructions are the great majority of the buildings in Europe’s historic centres and the most important monuments of its architectural heritage. Given the age of these constructions, the demand for safety assessments and restoration projects is pressing and constant; still within the broad studies in the subject it is not yet recognised, in particular within the seismic area, a unitary approach to deal with Masonry structures. This successful book contributes to clarify the issues with a rigorous approach offering a comprehensive new Statics of Masonry Constructions. This third edition has been driven by some recent developments of the research in the field, and it gives the fundamentals of Statics with an original and rigorous mathematical formulation, further in-depth inquired in this new version. With many refinements and improvements, the book investigates the static behaviour of many historic monuments, such as the Gothic Cathedrals, the Mycenaean Tholoi, the Pantheon, the Colosseum, the dome...

  12. Non-local means filter for trim statics

    KAUST Repository

    Huang, Yunsong; Wang, Xin; Schuster, Gerard T.

    2014-01-01

    this problem, we propose a trim statics inspired by the non-local means algorithm originally developed for image denoising. This method differs from the conventional one in two fundamental respects. First, the trim statics are computed by comparing image

  13. Numerical study on static component generation from the primary Lamb waves propagating in a plate with nonlinearity

    Science.gov (United States)

    Wan, Xiang; Tse, Peter W.; Zhang, Xuhui; Xu, Guanghua; Zhang, Qing; Fan, Hongwei; Mao, Qinghua; Dong, Ming; Wang, Chuanwei; Ma, Hongwei

    2018-04-01

    Under the discipline of nonlinear ultrasonics, in addition to second harmonic generation, static component generation is another frequently used nonlinear ultrasonic behavior in non-destructive testing (NDT) and structural health monitoring (SHM) communities. However, most previous studies on static component generation are mainly based on using longitudinal waves. It is desirable to extend static component generation from primary longitudinal waves to primary Lamb waves. In this paper, static component generation from the primary Lamb waves is studied. Two major issues are numerically investigated. First, the mode of static displacement component generated from different primary Lamb wave modes is identified. Second, cumulative effect of static displacement component from different primary Lamb wave modes is also discussed. Our study results show that the static component wave packets generated from the primary S0, A0 and S1 modes share the almost same group velocity equal to the phase velocity of S0 mode tending to zero frequency c plate . The finding indicates that whether the primary mode is S0, A0 or S1, the static components generated from these primary modes always share the nature of S0 mode. This conclusion is also verified by the displacement filed of these static components that the horizontal displacement field is almost uniform and the vertical displacement filed is antisymmetric across the thickness of the plate. The uniform distribution of horizontal displacement filed enables the static component, regardless of the primary Lamb modes, to be a promising technique for evaluating microstructural damages buried in the interior of a structure. Our study also illustrates that the static components are cumulative regardless of whether the phase velocity of the primary and secondary waves is matched or not. This observation indicates that the static component overcomes the limitations of the traditional nonlinear Lamb waves satisfying phase velocity

  14. Effects of Water and Land-based Sensorimotor Training Programs on Static Balance among University Students

    OpenAIRE

    Abdolhamid Daneshjoo; Ashril Yusof

    2016-01-01

    This study examined the effect of sensorimotor training on static balance in two different environments; in water and on land. Thirty non-clinical university male students (aged 22±0.85 years) were divided randomly into three groups; water, land and control groups. The experimental groups performed their respective sensorimotor training programs for 6 weeks (3 times per week). The Stork Stand Balance Test was used to examine the static balance at pre- and post-time points. Significant main ef...

  15. Influence of relative humidity and temperature on quantity of electric charge of static protective clothing used in petrochemical industry

    Science.gov (United States)

    Zhang, Yunpeng; Liu, Quanzhen; Liu, Baoquan; Li, Yipeng; Zhang, Tingting

    2013-03-01

    In this paper, the working principle of static protective clothing and its testing method of quantity of electric charge are introduced, and the influence of temperature and relative humidity on the quantity of electric charge (qe) of static protective clothing is studied by measuring qe of different clothing samples. The result shows that temperature and relative humidity can influence qe of static protective clothing to some extent and the influence of relative humidity is bigger than that of temperature. According to experimental results, the relationship of qe and relative humidity and temperature was analysed, and the safety boundary of quantity of electric charge is discussed. In order to reduce the occurrence of electrostatic accidents and ensure safe production and operation of petrochemical industry, some suggestions on choosing and using of static protective clothing are given for guaranteeing its static protective performance.

  16. Effect of Static-Dynamic Coupling Loading on Fracture Toughness and Failure Characteristics in Marble

    Directory of Open Access Journals (Sweden)

    Z. Q. Yin

    2014-03-01

    Full Text Available Fracture experiments in a notched semi-circular bend configuration were conducted to test the dynamic fracture toughness of a marble under static-dynamic coupling load using a modified split Hopkinson pressure bar. The fracture process of the specimen was monitored using a high speed (HS camera. Based on digital image correlation (DIC and strain gauges, the full-field strain fields and time-to-fracture of the marble were measured under static-dynamic coupling load. Experimental results show that dynamic fracture toughness was well determined, and the HS-DIC technique provides reliable full-field strain fields in the specimens under static-dynamic coupling loads. The failure characteristics of the marble under external impact were affected obviously by pre-compression stress. Increase of axial pre-compression stress was helpful to improve the crack propagation velocity, and dynamic crack initiation toughness was decreased.

  17. Counterterms for static Lovelock solutions

    International Nuclear Information System (INIS)

    Mehdizadeh, M.R.; Dehghani, M.H.; Zangeneh, M.K.

    2015-01-01

    In this paper, we introduce the counterterms that remove the non-logarithmic divergences of the action in third order Lovelock gravity for static spacetimes. We do this by defining the cosmological constant in such a way that the asymptotic form of the metric have the same form in Lovelock and Einstein gravities. Thus, we employ the counterterms of Einstein gravity and show that the power law divergences of the action of Lovelock gravity for static spacetimes can be removed by suitable choice of coefficients. We find that the dependence of these coefficients on the dimension in Lovelock gravity is the same as in Einstein gravity. We also introduce the finite energy-momentum tensor and employ these counterterms to calculate the finite action and mass of static black hole solutions of third order Lovelock gravity. Next, we calculate the thermodynamic quantities and show that the entropy calculated through the use of Gibbs-Duhem relation is consistent with the obtained entropy by Wald's formula. Furthermore, we find that in contrast to Einstein gravity in which there exists no uncharged extreme black hole, third order Lovelock gravity can have these kind of black holes. Finally, we investigate the stability of static charged black holes of Lovelock gravity in canonical ensemble and find that small black holes show a phase transition between very small and small black holes, while the large ones are stable. (orig.)

  18. Counterterms for static Lovelock solutions

    Energy Technology Data Exchange (ETDEWEB)

    Mehdizadeh, M.R. [Shahid Bahonar University, Department of Physics, PO Box 76175, Kerman (Iran, Islamic Republic of); Dehghani, M.H. [Research Institute for Astrophysics and Astronomy of Maragha (RIAAM), Maragha (Iran, Islamic Republic of); Shiraz University, Physics Department and Biruni Observatory, College of Sciences, Shiraz (Iran, Islamic Republic of); Zangeneh, M.K. [Shiraz University, Physics Department and Biruni Observatory, College of Sciences, Shiraz (Iran, Islamic Republic of)

    2015-06-15

    In this paper, we introduce the counterterms that remove the non-logarithmic divergences of the action in third order Lovelock gravity for static spacetimes. We do this by defining the cosmological constant in such a way that the asymptotic form of the metric have the same form in Lovelock and Einstein gravities. Thus, we employ the counterterms of Einstein gravity and show that the power law divergences of the action of Lovelock gravity for static spacetimes can be removed by suitable choice of coefficients. We find that the dependence of these coefficients on the dimension in Lovelock gravity is the same as in Einstein gravity. We also introduce the finite energy-momentum tensor and employ these counterterms to calculate the finite action and mass of static black hole solutions of third order Lovelock gravity. Next, we calculate the thermodynamic quantities and show that the entropy calculated through the use of Gibbs-Duhem relation is consistent with the obtained entropy by Wald's formula. Furthermore, we find that in contrast to Einstein gravity in which there exists no uncharged extreme black hole, third order Lovelock gravity can have these kind of black holes. Finally, we investigate the stability of static charged black holes of Lovelock gravity in canonical ensemble and find that small black holes show a phase transition between very small and small black holes, while the large ones are stable. (orig.)

  19. Cognition and sensation in very high static magnetic fields: a randomized case-crossover study with different field strengths.

    Science.gov (United States)

    Heinrich, Angela; Szostek, Anne; Meyer, Patric; Nees, Frauke; Rauschenberg, Jaane; Gröbner, Jens; Gilles, Maria; Paslakis, Georgios; Deuschle, Michael; Semmler, Wolfhard; Flor, Herta

    2013-01-01

    To establish the extent to which representative cognitive functions in subjects undergoing magnetic resonance (MR) imaging are acutely impaired by static magnetic fields of varying field strengths. This study was approved by the local ethics committee, and informed consent was obtained from all subjects. In this single-blind case-crossover study, 41 healthy subjects underwent an extensive neuropsychologic examination while in MR units of differing field strengths (1.5, 3.0, and 7.0 T), including a mock imager with no magnetic field as a control condition. Subjects were blinded to field strength. Tests were performed while subjects were lying still in the MR unit and while the examination table was moved. The tests covered a representative set of cognitive functions, such as memory, eye-hand coordination, attention, reaction time, and visual discrimination. Subjective sensory perceptions were also assessed. Effects were analyzed with a repeated-measures analysis of variance; the within-subject factors were field strength (0, 1.5, 3.0, and 7.0 T) and state (static, dynamic). Static magnetic fields were not found to have a significant effect on cognitive function at any field strength. However, sensory perceptions did vary according to field strength. Dizziness, nystagmus, phosphenes, and head ringing were related to the strength of the static magnetic field. Static magnetic fields as high as 7.0 T did not have a significant effect on cognition. RSNA, 2012

  20. Flight Test Results of a GPS-Based Pitot-Static Calibration Method Using Output-Error Optimization for a Light Twin-Engine Airplane

    Science.gov (United States)

    Martos, Borja; Kiszely, Paul; Foster, John V.

    2011-01-01

    As part of the NASA Aviation Safety Program (AvSP), a novel pitot-static calibration method was developed to allow rapid in-flight calibration for subscale aircraft while flying within confined test areas. This approach uses Global Positioning System (GPS) technology coupled with modern system identification methods that rapidly computes optimal pressure error models over a range of airspeed with defined confidence bounds. This method has been demonstrated in subscale flight tests and has shown small 2- error bounds with significant reduction in test time compared to other methods. The current research was motivated by the desire to further evaluate and develop this method for full-scale aircraft. A goal of this research was to develop an accurate calibration method that enables reductions in test equipment and flight time, thus reducing costs. The approach involved analysis of data acquisition requirements, development of efficient flight patterns, and analysis of pressure error models based on system identification methods. Flight tests were conducted at The University of Tennessee Space Institute (UTSI) utilizing an instrumented Piper Navajo research aircraft. In addition, the UTSI engineering flight simulator was used to investigate test maneuver requirements and handling qualities issues associated with this technique. This paper provides a summary of piloted simulation and flight test results that illustrates the performance and capabilities of the NASA calibration method. Discussion of maneuver requirements and data analysis methods is included as well as recommendations for piloting technique.

  1. A study of long-term static load on degradation and mechanical integrity of Mg alloys-based biodegradable metals

    International Nuclear Information System (INIS)

    Koo, Youngmi; Jang, Yongseok; Yun, Yeoheung

    2017-01-01

    Highlights: • Long-term stress corrosion cracking (SCC) test of Mg alloys was performed. • AZ31B-H24 shows transgranular stress corrosion cracking (TGSCC) and ZE41A-T5 intergranular stress corrosion cracking (IGSCC). • Long-term static loading accelerated crack propagation, leading to the loss of mechanical strength. - Abstract: Predicting degradation behavior of biodegradable metals in vivo is crucial for the clinical success of medical devices. This paper reports on the effect of long-term static stress on degradation of magnesium alloys and further changes in mechanical integrity. AZ31B (H24) and ZE41A (T5) alloys were tested to evaluate stress corrosion cracking (SCC) in a physiological solution for 30 days and 90 days (ASTM G39 testing standard). Scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDX) and micro-computed tomography (micro-CT) were used to characterize surface morphology and micro-structure of degraded alloys. The results show the different mechanisms of stress corrosion cracking for AZ31B (transgranular stress corrosion cracking, TGSCC) and ZE41A (intergranular stress corrosion cracking, IGSCC). AZ31B was more susceptible to stress corrosion cracking under a long term static load than ZE41A. In conclusion, we observed that long-term static loading accelerated crack propagation, leading to the loss of mechanical integrity.

  2. A study of long-term static load on degradation and mechanical integrity of Mg alloys-based biodegradable metals

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Youngmi; Jang, Yongseok; Yun, Yeoheung, E-mail: yyun@ncat.edu

    2017-05-15

    Highlights: • Long-term stress corrosion cracking (SCC) test of Mg alloys was performed. • AZ31B-H24 shows transgranular stress corrosion cracking (TGSCC) and ZE41A-T5 intergranular stress corrosion cracking (IGSCC). • Long-term static loading accelerated crack propagation, leading to the loss of mechanical strength. - Abstract: Predicting degradation behavior of biodegradable metals in vivo is crucial for the clinical success of medical devices. This paper reports on the effect of long-term static stress on degradation of magnesium alloys and further changes in mechanical integrity. AZ31B (H24) and ZE41A (T5) alloys were tested to evaluate stress corrosion cracking (SCC) in a physiological solution for 30 days and 90 days (ASTM G39 testing standard). Scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDX) and micro-computed tomography (micro-CT) were used to characterize surface morphology and micro-structure of degraded alloys. The results show the different mechanisms of stress corrosion cracking for AZ31B (transgranular stress corrosion cracking, TGSCC) and ZE41A (intergranular stress corrosion cracking, IGSCC). AZ31B was more susceptible to stress corrosion cracking under a long term static load than ZE41A. In conclusion, we observed that long-term static loading accelerated crack propagation, leading to the loss of mechanical integrity.

  3. Comparison of stochastic resonance in static and dynamical nonlinearities

    International Nuclear Information System (INIS)

    Ma, Yumei; Duan, Fabing

    2014-01-01

    We compare the stochastic resonance (SR) effects in parallel arrays of static and dynamical nonlinearities via the measure of output signal-to-noise ratio (SNR). For a received noisy periodic signal, parallel arrays of both static and dynamical nonlinearities can enhance the output SNR by optimizing the internal noise level. The static nonlinearity is easily implementable, while the dynamical nonlinearity has more parameters to be tuned, at the risk of not exploiting the beneficial role of internal noise components. It is of interest to note that, for an input signal buried in the external Laplacian noise, we show that the dynamical nonlinearity is superior to the static nonlinearity in obtaining a better output SNR. This characteristic is assumed to be closely associated with the kurtosis of noise distribution. - Highlights: • Comparison of SR effects in arrays of both static and dynamical nonlinearities. • Static nonlinearity is easily implementable for the SNR enhancement. • Dynamical nonlinearity yields a better output SNR for external Laplacian noise

  4. Static and dynamic postural control in low-vision and normal-vision adults.

    Science.gov (United States)

    Tomomitsu, Mônica S V; Alonso, Angelica Castilho; Morimoto, Eurica; Bobbio, Tatiana G; Greve, Julia M D

    2013-04-01

    This study aimed to evaluate the influence of reduced visual information on postural control by comparing low-vision and normal-vision adults in static and dynamic conditions. Twenty-five low-vision subjects and twenty-five normal sighted adults were evaluated for static and dynamic balance using four protocols: 1) the Modified Clinical Test of Sensory Interaction on Balance on firm and foam surfaces with eyes opened and closed; 2) Unilateral Stance with eyes opened and closed; 3) Tandem Walk; and 4) Step Up/Over. The results showed that the low-vision group presented greater body sway compared with the normal vision during balance on a foam surface (p≤0.001), the Unilateral Stance test for both limbs (p≤0.001), and the Tandem Walk test. The low-vision group showed greater step width (p≤0.001) and slower gait speed (p≤0.004). In the Step Up/Over task, low-vision participants were more cautious in stepping up (right p≤0.005 and left p≤0.009) and in executing the movement (p≤0.001). These findings suggest that visual feedback is crucial for determining balance, especially for dynamic tasks and on foam surfaces. Low-vision individuals had worse postural stability than normal-vision adults in terms of dynamic tests and balance on foam surfaces.

  5. Static Transition Compression

    DEFF Research Database (Denmark)

    Danvy, Olivier; Damian, Daniel

    2001-01-01

    Starting from an operational specification of a translation from a structured to an unstructured imperative language, we point out how a compositional and context-insensitive translation gives rise to static chains of jumps. Taking an inspiration from the notion of continuation, we state a new co...

  6. Mechanical strength of an ITER coil insulation system under static and dynamic load after reactor irradiation

    International Nuclear Information System (INIS)

    Bittner-Rohrhofer, K.; Humer, K.; Weber, H.W.; Hamada, K.; Sugimoto, M.; Okuno, K.

    2002-01-01

    The insulation system proposed by the Japanese Home Team for the ITER Toroidal Field coil (TF coil) is a T-glass-fiber/Kapton reinforced epoxy prepreg system. In order to assess the material performance under the actual operating conditions of the coils, the insulation system was irradiated in the TRIGA reactor (Vienna) to a fast neutron fluence of 2x10 22 m -2 (E>0.1 MeV). After measurements of swelling, all mechanical tests were carried out at 77 K. Tensile and short-beam-shear (SBS) tests were performed under static loading conditions. In addition, tension-tension fatigue experiments up to about 10 6 cycles were made. The laminate swells in the through-thickness direction by 0.86% at the highest dose level. The fatigue tests as well as the static tests do not show significant influences of the irradiation on the mechanical behavior of this composite

  7. Mechanical strength of an ITER coil insulation system under static and dynamic load after reactor irradiation

    Science.gov (United States)

    Bittner-Rohrhofer, K.; Humer, K.; Weber, H. W.; Hamada, K.; Sugimoto, M.; Okuno, K.

    2002-12-01

    The insulation system proposed by the Japanese Home Team for the ITER Toroidal Field coil (TF coil) is a T-glass-fiber/Kapton reinforced epoxy prepreg system. In order to assess the material performance under the actual operating conditions of the coils, the insulation system was irradiated in the TRIGA reactor (Vienna) to a fast neutron fluence of 2×10 22 m -2 ( E>0.1 MeV). After measurements of swelling, all mechanical tests were carried out at 77 K. Tensile and short-beam-shear (SBS) tests were performed under static loading conditions. In addition, tension-tension fatigue experiments up to about 10 6 cycles were made. The laminate swells in the through-thickness direction by 0.86% at the highest dose level. The fatigue tests as well as the static tests do not show significant influences of the irradiation on the mechanical behavior of this composite.

  8. Intercomparison of leach-testing methods and the effects of waste-form composition on test type and duration

    International Nuclear Information System (INIS)

    Harvey, K.B.; Jensen, C.D.

    1982-01-01

    Several leach-testing methods were evaluated for their relevance as scoping tests appropriate to proposed Canadian conditions for the disposal of high-level nuclear waste, and a static, terminated leach test was chosen. For a particular glass composition, methods in which the leachant was replenished gave apparent leach rates up to ten times less than did the static test. Under static leaching conditions, the leach rate of a number of sodium borosilicate glasses was observed to first rise and then fall with leaching time. This behavior is explained in terms of a pH change in the leachant, which is itself a function of the glass composition. The implications of these observations on glass compositions and on leach-testing methods that are relevant to the needs of final disposal are briefly discussed

  9. 14 CFR 25.173 - Static longitudinal stability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Static longitudinal stability. 25.173... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Flight Stability § 25.173 Static... forces (including friction) must be as follows: (a) A pull must be required to obtain and maintain speeds...

  10. Validation and test report

    DEFF Research Database (Denmark)

    Pedersen, Jens Meldgaard; Andersen, T. Bull

    2012-01-01

    . As a consequence of extensive movement artefacts seen during dynamic contractions, the following validation and test report consists of a report that investigates the physiological responses to a static contraction in a standing and a supine position. Eight subjects performed static contractions of the ankle...

  11. Effect of static scatterers in laser speckle contrast imaging: an experimental study on correlation and contrast

    Science.gov (United States)

    Vaz, Pedro G.; Humeau-Heurtier, Anne; Figueiras, Edite; Correia, Carlos; Cardoso, João

    2018-01-01

    Laser speckle contrast imaging (LSCI) is a non-invasive microvascular blood flow assessment technique with good temporal and spatial resolution. Most LSCI systems, including commercial devices, can perform only qualitative blood flow evaluation, which is a major limitation of this technique. There are several factors that prevent the utilization of LSCI as a quantitative technique. Among these factors, we can highlight the effect of static scatterers. The goal of this work was to study the influence of differences in static and dynamic scatterer concentration on laser speckle correlation and contrast. In order to achieve this, a laser speckle prototype was developed and tested using an optical phantom with various concentrations of static and dynamic scatterers. It was found that the laser speckle correlation could be used to estimate the relative concentration of static/dynamic scatterers within a sample. Moreover, the speckle correlation proved to be independent of the dynamic scatterer velocity, which is a fundamental characteristic to be used in contrast correction.

  12. A Minimum Leakage Quasi-Static RAM Bitcell

    Directory of Open Access Journals (Sweden)

    Adam Teman

    2011-05-01

    Full Text Available As SRAMs continue to grow and comprise larger percentages of the area and power consumption in advanced systems, the need to minimize static currents becomes essential. This brief presents a novel 9T Quasi-Static RAM Bitcell that provides aggressive leakage reduction and high write margins. The quasi-static operation method of this cell, based on internal feedback and leakage ratios, minimizes static power while maintaining sufficient, albeit depleted, noise margins. This paper presents the concept of the novel cell, and discusses the stability of the cell under hold, read and write operations. The cell was implemented in a low-power 40 nm TSMC process, showing as much as a 12× reduction in leakage current at typical conditions, as compared to a standard 6T or 8T bitcell at the same supply voltage. The implemented cell showed full functionality under global and local process variations at nominal and low voltages, as low as 300 mV.

  13. Static magnetic field effects on proteases with fibrinolytic activity produced by Mucor subtilissimus.

    Science.gov (United States)

    Albuquerque, Wendell; Nascimento, Thiago; Brandão-Costa, Romero; Fernandes, Thiago; Porto, Ana

    2017-02-01

    The influence of a static magnetic field (SMF) on crude enzyme extracts with proteolytic activity is described and discussed. Proteolytic enzymes, which hydrolyze peptide bonds, and fibrinolytic enzymes, which dissolve fibrin clots, have industrial relevance, and applicability dependent on improvements of productivity and activity. We investigated whether a moderate SMF affects proteolysis in different in vitro tests: general proteolysis of azocasein substrate, and static and dynamic fibrinolytic processes (to compare fibrin gel configuration under exposure). Crude enzyme extracts, obtained from solid state fermentation of Mucor subtilissimus UCP (Universidade Católica de Pernambuco, Recife, Brazil) 1262, were used to carry out assays under slightly heterogeneous fields: a varied vertical SMF (for tests in Eppendorf tubes, from 0.100 to 0.170 T) and a varied horizontal SMF (for tests in Petri dishes, from 0.01 to 0.122 T), generated by two permanent magnets (NdFeB alloy). Results showed significant differences (P < 0.05) in static fibrinolysis assays after 24 h of exposure. The mean diameter of halos of fibrin degradation in the treated group increased by 21% compared to the control group; and the pixel number count of fibrin consumption (in a computational analysis of the area of each halo) enhanced by 30% with exposure. However, in dynamic fibrinolysis assays, no effects of SMF were observed. These results suggest a response of fibrin monomers to the SMF as a possible cause of the observed effects. Bioelectromagnetics. 38:109-120, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Influence of relative humidity and temperature on quantity of electric charge of static protective clothing used in petrochemical industry

    International Nuclear Information System (INIS)

    Zhang, Yunpeng; Liu, Quanzhen; Liu, Baoquan; Li, Yipeng; Zhang, Tingting

    2013-01-01

    In this paper, the working principle of static protective clothing and its testing method of quantity of electric charge are introduced, and the influence of temperature and relative humidity on the quantity of electric charge (q e ) of static protective clothing is studied by measuring q e of different clothing samples. The result shows that temperature and relative humidity can influence q e of static protective clothing to some extent and the influence of relative humidity is bigger than that of temperature. According to experimental results, the relationship of q e and relative humidity and temperature was analysed, and the safety boundary of quantity of electric charge is discussed. In order to reduce the occurrence of electrostatic accidents and ensure safe production and operation of petrochemical industry, some suggestions on choosing and using of static protective clothing are given for guaranteeing its static protective performance.

  15. Crippling load test of Budd Pioneer Car 244, test 3.

    Science.gov (United States)

    2013-04-01

    This report summarizes Test 3, a crippling load test on Budd Pioneer Car 244, conducted on June 28, 2011. Before the crippling load test, Transportation Technology Center, Inc., conducted two 800,000-pound (lb) quasi-static tests on Car 244 in accord...

  16. Modeling Quasi-Static and Fatigue-Driven Delamination Migration

    Science.gov (United States)

    De Carvalho, N. V.; Ratcliffe, J. G.; Chen, B. Y.; Pinho, S. T.; Baiz, P. M.; Tay, T. E.

    2014-01-01

    An approach was proposed and assessed for the high-fidelity modeling of progressive damage and failure in composite materials. It combines the Floating Node Method (FNM) and the Virtual Crack Closure Technique (VCCT) to represent multiple interacting failure mechanisms in a mesh-independent fashion. Delamination, matrix cracking, and migration were captured failure and migration criteria based on fracture mechanics. Quasi-static and fatigue loading were modeled within the same overall framework. The methodology proposed was illustrated by simulating the delamination migration test, showing good agreement with the available experimental data.

  17. The Static Ladder Problem with Two Sources of Friction

    Science.gov (United States)

    Bennett, Jonathan; Mauney, Alex

    2011-01-01

    The problem of a ladder leaning against a wall in static equilibrium is a classic example encountered in introductory mechanics texts. Most discussions of this problem assume that the static frictional force between the ladder and wall can be ignored. A few authors consider the case where the static friction coefficients between ladder/wall…

  18. The usefulness of cardiofocal collimator in static renal imaging

    International Nuclear Information System (INIS)

    Evren, I.; Durak, H.; Degirmenci, B.; Derebek, E.; Oezbilek, E.; Capa, G.

    2001-01-01

    Static renal imaging is best performed using pinhole collimator. But this technique takes too much time and generally parallel hole collimators are preferred for static renal imaging in nuclear medicine departments. The purpose of this study was to investigate the usefulness of the cardio-focal collimator used for myocardial perfusion imaging in static renal scintigraphy

  19. An FDTD algorithm for simulation of EM waves propagation in laser with static and dynamic gain models

    KAUST Repository

    Al-Jabr, Ahmad Ali; Alsunaidi, Mohammad A.; Ooi, Boon S.

    2013-01-01

    This paper presents methods of simulating gain media in the finite difference time-domain (FDTD) algorithm utilizing a generalized polarization formulation. The gain can be static or dynamic. For static gain, Lorentzian and non-Lorentzian models are presented and tested. For the dynamic gain, rate equations for two-level and four-level models are incorporated in the FDTD scheme. The simulation results conform with the expected behavior of wave amplification and dynamic population inversion.

  20. 14 CFR 23.173 - Static longitudinal stability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Static longitudinal stability. 23.173... Stability § 23.173 Static longitudinal stability. Under the conditions specified in § 23.175 and with the airplane trimmed as indicated, the characteristics of the elevator control forces and the friction within...

  1. 14 CFR 25.1325 - Static pressure systems.

    Science.gov (United States)

    2010-01-01

    ... installation of the static pressure system must be such that— (1) Positive drainage of moisture is provided..., the other is blocked off; and (2) Both sources cannot be blocked off simultaneously. (h) For... other static pressure source being open or blocked. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as...

  2. The clinical application of static-fluid MRU and enhanced MRU for the diagnosis of upper urinary tract disease

    International Nuclear Information System (INIS)

    Hu Bing; Ye Binbin; Kang Zhuang; Zou Yan

    2005-01-01

    Objective: To evaluate the clinical utility of heavy T 2 -weighted MR urography (static-fluid MRU) and gadolinium-enhanced T 1 -weighted MR urography (enhanced MRU) for the diagnosis of upper urinary tract disease. Methods: Eleven patients were examined with static-fluid MRU and enhanced MRU. The images of static-fluid MRU and enhanced MRU were ranked and diagnosed by two radiologists. And the results were compared later. Results: The ranked image quality was analyzed with a Wilcoxon sign-rank test. The difference between two kinds of MRU images was not significant (P>0.05). The number of correct diagnosis of static-fluid MRU was 19(86.4%) by observer A and 18 (81.8%) by observer B; of enhanced MRU was 21 (95.5%) by observer A and 19 (86.4%) by observer B. Conclusion: With static-fluid MRU, the intraluminal anatomy of urinary tract can be displayed, but the function of kidney can not be evaluated. With enhanced MRU, the intraluminal anatomy can be displayed, and the function of kidney can be evaluated as well. Most of upper urinary tract disease could be diagnosed by static-fluid MRU or enhanced MRU. (authors)

  3. Manual for Cyclic Triaxial Test

    DEFF Research Database (Denmark)

    Shajarati, Amir; Sørensen, Kris Wessel; Nielsen, Søren Kjær

    This manual describes the different steps that is included in the procedure for conducting a cyclic triaxial test at the geotechnical Laboratory at Aalborg University. Furthermore it contains a chapter concerning some of the background theory for the static triaxial tests. The cyclic/dynamic tria......This manual describes the different steps that is included in the procedure for conducting a cyclic triaxial test at the geotechnical Laboratory at Aalborg University. Furthermore it contains a chapter concerning some of the background theory for the static triaxial tests. The cyclic...

  4. Static potential for a string with a topological term

    International Nuclear Information System (INIS)

    Zaikov, R.P.; Zlatev, S.I.

    1991-01-01

    We study the static potential for a string in (2+1)-dimensional space-time with action including a topological term. An appropriate static solution is found and the corresponding potential is obtained. Such a solution does not exist beyond a critical distance between the ends of the string. The one-loop corrections to the static potential are calculated. (orig.)

  5. Dynamical analysis of a PWR internals using super-elements in an integrated 3-D model model. Part 1: model description and static tests

    International Nuclear Information System (INIS)

    Jesus Miranda, C.A. de.

    1992-01-01

    An integrated 3-D model of a research PWR reactor core support internals structures was developed for its dynamic analyses. The static tests for the validation of the model are presented. There are about 90 super-elements with, approximately, 85000 degrees of freedom (DoF), 8200 masters DoF, 12000 elements with about 8400 thin shell elements. A DEC VAX computer 11/785 model and the ANSYS program were used. If impacts occurs the spectral seismic analysis will be changed to a non-linear one with direct integration of the displacement pulse derived from the seismic accelerogram. This last will be obtained from the seismic acceleration response spectra. (author)

  6. Dynamic augmentation restores anterior tibial translation in ACL suture repair: a biomechanical comparison of non-, static and dynamic augmentation techniques.

    Science.gov (United States)

    Hoogeslag, Roy A G; Brouwer, Reinoud W; Huis In 't Veld, Rianne; Stephen, Joanna M; Amis, Andrew A

    2018-02-03

    There is a lack of objective evidence investigating how previous non-augmented ACL suture repair techniques and contemporary augmentation techniques in ACL suture repair restrain anterior tibial translation (ATT) across the arc of flexion, and after cyclic loading of the knee. The purpose of this work was to test the null hypotheses that there would be no statistically significant difference in ATT after non-, static- and dynamic-augmented ACL suture repair, and they will not restore ATT to normal values across the arc of flexion of the knee after cyclic loading. Eleven human cadaveric knees were mounted in a test rig, and knee kinematics from 0° to 90° of flexion were recorded by use of an optical tracking system. Measurements were recorded without load and with 89-N tibial anterior force. The knees were tested in the following states: ACL-intact, ACL-deficient, non-augmented suture repair, static tape augmentation and dynamic augmentation after 10 and 300 loading cycles. Only static tape augmentation and dynamic augmentation restored ATT to values similar to the ACL-intact state directly postoperation, and maintained this after cyclic loading. However, contrary to dynamic augmentation, the ATT after static tape augmentation failed to remain statistically less than for the ACL-deficient state after cyclic loading. Moreover, after cyclic loading, ATT was significantly less with dynamic augmentation when compared to static tape augmentation. In contrast to non-augmented ACL suture repair and static tape augmentation, only dynamic augmentation resulted in restoration of ATT values similar to the ACL-intact knee and decreased ATT values when compared to the ACL-deficient knee immediately post-operation and also after cyclic loading, across the arc of flexion, thus allowing the null hypotheses to be rejected. This may assist healing of the ruptured ACL. Therefore, this study would support further clinical evaluation of dynamic augmentation of ACL repair.

  7. Secure communication of static information by electronic means

    Science.gov (United States)

    Gritton, Dale G.

    1994-01-01

    A method and apparatus (10) for the secure transmission of static data (16) from a tag (11) to a remote reader (12). Each time the static data (16) is to be transmitted to the reader (12), the 10 bits of static data (16) are combined with 54 bits of binary data (21), which constantly change from one transmission to the next, into a 64-bit number (22). This number is then encrypted and transmitted to the remote reader (12) where it is decrypted (26) to produce the same 64 bit number that was encrypted in the tag (11). With a continual change in the value of the 64 bit number (22) in the tag, the encrypted numbers transmitted to the reader (12) will appear to be dynamic in character rather than being static.

  8. Static mechanical properties of buffer material

    International Nuclear Information System (INIS)

    Takaji, Kazuhiko; Suzuki, Hideaki

    1999-11-01

    The buffer material is expected to maintain its low water permeability, self-sealing properties, radionuclides adsorption and retardation properties, thermal conductivity, chemical buffering properties, overpack supporting properties, stress buffering properties, etc. over a long period of time. Natural clay is mentioned as a material that can relatively satisfy above. Among the kinds of natural clay, bentonite when compacted is superior because (i) it has exceptionally low water permeability and properties to control the movement of water in buffer, (ii) it fills void spaces in the buffer and fractures in the host rock as it swells upon water uptake, (iii) it has the ability to exchange cations and to adsorb cationic radioelements. In order to confirm these functions for the purpose of safety assessment, it is necessary to evaluate buffer properties through laboratory tests and engineering-scale tests, and to make assessments based on the ranges in the data obtained. This report describes the procedures, test conditions, results and examinations on the buffer material of unconfined compression tests, one-dimensional consolidation tests, consolidated-undrained triaxial compression tests and consolidated-undrained triaxial creep tests that aim at getting hold of static mechanical properties. We can get hold of the relationship between the dry density and tensile stress etc. by Brazilian tests, between the dry density and unconfined compressive strength etc. by unconfined compression tests, between the consolidation stress and void ratio etc. by one-dimensional consolidation tests, the stress pass of each effective confining pressure etc. by consolidated-undrained triaxial compression tests and the axial strain rate with time of each axial stress etc. by consolidated-undrained triaxial creep tests. (author)

  9. A static investigation of the thrust vectoring system of the F/A-18 high-alpha research vehicle

    Science.gov (United States)

    Mason, Mary L.; Capone, Francis J.; Asbury, Scott C.

    1992-01-01

    A static (wind-off) test was conducted in the static test facility of the Langley 16-foot Transonic Tunnel to evaluate the vectoring capability and isolated nozzle performance of the proposed thrust vectoring system of the F/A-18 high alpha research vehicle (HARV). The thrust vectoring system consisted of three asymmetrically spaced vanes installed externally on a single test nozzle. Two nozzle configurations were tested: A maximum afterburner-power nozzle and a military-power nozzle. Vane size and vane actuation geometry were investigated, and an extensive matrix of vane deflection angles was tested. The nozzle pressure ratios ranged from two to six. The results indicate that the three vane system can successfully generate multiaxis (pitch and yaw) thrust vectoring. However, large resultant vector angles incurred large thrust losses. Resultant vector angles were always lower than the vane deflection angles. The maximum thrust vectoring angles achieved for the military-power nozzle were larger than the angles achieved for the maximum afterburner-power nozzle.

  10. Static and Fatigue Behavior Investigation of Artificial Notched Steel Reinforcement

    Directory of Open Access Journals (Sweden)

    Yafei Ma

    2017-05-01

    Full Text Available Pitting corrosion is one of the most common forms of localized corrosion. Corrosion pit results in a stress concentration and fatigue cracks usually initiate and propagate from these corrosion pits. Aging structures may fracture when the fatigue crack reaches a critical size. This paper experimentally simulates the effects of pitting morphologies on the static and fatigue behavior of steel bars. Four artificial notch shapes are considered: radial ellipse, axial ellipse, triangle and length-variable triangle. Each shape notch includes six sizes to simulate a variety of pitting corrosion morphologies. The stress-strain curves of steel bars with different notch shape and depth are obtained based on static tensile testing, and the stress concentration coefficients for various conditions are determined. It was determined that the triangular notch has the highest stress concentration coefficient, followed by length-variable triangle, radial ellipse and axial ellipse shaped notches. Subsequently, the effects of notch depth and notch aspect ratios on the fatigue life under three stress levels are investigated by fatigue testing, and the equations for stress range-fatigue life-notch depth are obtained. Several conclusions are drawn based on the proposed study. The established relationships provide an experimental reference for evaluating the fatigue life of concrete bridges.

  11. Measurement of in-vehicle volatile organic compounds under static conditions.

    Science.gov (United States)

    You, Ke-wei; Ge, Yun-shan; Hu, Bin; Ning, Zhan-wu; Zhao, Shou-tang; Zhang, Yan-ni; Xie, Peng

    2007-01-01

    The types and quantities of volatile organic compounds (VOCs) inside vehicles have been determined in one new vehicle and two old vehicles under static conditions using the Thermodesorber-Gas Chromatograph/Mass Spectrometer (TD-GC/MS). Air sampling and analysis was conducted under the requirement of USEPA Method TO-17. A room-size, environment test chamber was utilized to provide stable and accurate control of the required environmental conditions (temperature, humidity, horizontal and vertical airflow velocity, and background VOCs concentration). Static vehicle testing demonstrated that although the amount of total volatile organic compounds (TVOC) detected within each vehicle was relatively distinct (4940 microg/m3 in the new vehicle A, 1240 microg/m3 in used vehicle B, and 132 microg/m3 in used vehicle C), toluene, xylene, some aromatic compounds, and various C7-C12 alkanes were among the predominant VOC species in all three vehicles tested. In addition, tetramethyl succinonitrile, possibly derived from foam cushions was detected in vehicle B. The types and quantities of VOCs varied considerably according to various kinds of factors, such as, vehicle age, vehicle model, temperature, air exchange rate, and environment airflow velocity. For example, if the airflow velocity increases from 0.1 m/s to 0.7 m/s, the vehicle's air exchange rate increases from 0.15 h(-1) to 0.67 h(-1), and in-vehicle TVOC concentration decreases from 1780 to 1201 microg/m3.

  12. On the geometric phenomenology of static friction.

    Science.gov (United States)

    Ghosh, Shankar; Merin, A P; Nitsure, Nitin

    2017-09-06

    In this note we introduce a hierarchy of phase spaces for static friction, which give a graphical way to systematically quantify the directional dependence in static friction via subregions of the phase spaces. We experimentally plot these subregions to obtain phenomenological descriptions for static friction in various examples where the macroscopic shape of the object affects the frictional response. The phase spaces have the universal property that for any experiment in which a given object is put on a substrate fashioned from a chosen material with a specified nature of contact, the frictional behaviour can be read off from a uniquely determined classifying map on the control space of the experiment which takes values in the appropriate phase space.

  13. Pheromone Static Routing Strategy for Complex Networks

    Science.gov (United States)

    Hu, Mao-Bin; Henry, Y. K. Lau; Ling, Xiang; Jiang, Rui

    2012-12-01

    We adopt the concept of using pheromones to generate a set of static paths that can reach the performance of global dynamic routing strategy [Phys. Rev. E 81 (2010) 016113]. The path generation method consists of two stages. In the first stage, a pheromone is dropped to the nodes by packets forwarded according to the global dynamic routing strategy. In the second stage, pheromone static paths are generated according to the pheromone density. The output paths can greatly improve traffic systems' overall capacity on different network structures, including scale-free networks, small-world networks and random graphs. Because the paths are static, the system needs much less computational resources than the global dynamic routing strategy.

  14. Sawja: Static Analysis Workshop for Java

    Science.gov (United States)

    Hubert, Laurent; Barré, Nicolas; Besson, Frédéric; Demange, Delphine; Jensen, Thomas; Monfort, Vincent; Pichardie, David; Turpin, Tiphaine

    Static analysis is a powerful technique for automatic verification of programs but raises major engineering challenges when developing a full-fledged analyzer for a realistic language such as Java. Efficiency and precision of such a tool rely partly on low level components which only depend on the syntactic structure of the language and therefore should not be redesigned for each implementation of a new static analysis. This paper describes the Sawja library: a static analysis workshop fully compliant with Java 6 which provides OCaml modules for efficiently manipulating Java bytecode programs. We present the main features of the library, including i) efficient functional data-structures for representing a program with implicit sharing and lazy parsing, ii) an intermediate stack-less representation, and iii) fast computation and manipulation of complete programs. We provide experimental evaluations of the different features with respect to time, memory and precision.

  15. Static electrification testing of Texas Utilities 345-20.9 kV, 650 MVA generator step-up transformer under controlled factory conditions

    International Nuclear Information System (INIS)

    Crofts, D.W.; Moore, H.

    1995-01-01

    Comanche Peak Nuclear Power Plant, with two 1150 Megawatt units, has two 345-20.9 kV, three-phase, 650 MVA transformers connected in parallel. The transformers have had a long history of hydrogen generation, and one of the Unit No. 2 transformers failed in 1983 while energized from the system for plant construction power. The failed unit was repaired and returned to Comanche Peak, and there was no evidence of static electrification involvement in the failure. During the time from installation to commercial operation in 1990 for Unit No. 1 and 1992 for Unit No. 2, the transformers were backfed from the system as needed to provide construction power. There was little regard paid to the operation of the cooling systems other than assuring the cooling was running. The transformers on unit No. 1 were subjected to several unusual electrical events - ferroresonance in 1981 and over excitation in 1983, with the generation of gasses of great concern. The decision was made to install a new transformer and return the old unit to the factory for diagnostic testing to determine the cause for the generation of combustible gas, primarily hydrogen. The dielectric integrity of the transformer could be quantified and decisions made concerning the replacement of the remaining transformers. After testing, the transformer was disassembled for forensic evaluation and rebuilt for return as a spare or to replace another transformer while undergoing repairs. Deformation of the bottom of the tank was discovered with large dents in the bottom protruding inward approximately one and one-half inches. With the concern of decreased clearances or displaced flux shields in the tank, an inspection opening was cut in the end of the transformer near the bottom. While investigating the deformation, evidence of partial discharge activity was discovered at the bottom of the high-to-low insulation; a location where static electrification damage has been observed in other large shell-form transformers

  16. Topological characterization of static strain aging of type AISI 304 austenitic stainless steel

    International Nuclear Information System (INIS)

    Monteiro, S.N.; Miranda, P.E.V. de

    1981-01-01

    Static strain aging of type AISI 304 austenitic stainless steel was studied from room temperature up to 623K by conducting tests in which the load was held approximately constant. The aging times varied between 10s and 100h, using a plastic pre-deformation of 9%. The static strain aging of 304 steel furnished an activation energy of 23.800 cal/mol. This implies that vacancies play an important role on the aging process. The curve of the variation of the discontinuous yielding with aging time presented different stages, to which specific mathematical expressions were developed. These facts permited the conclusion that Snock type mechanisms are responsible for the aging in such conditions. (Author) [pt

  17. Flight calibration of compensated and uncompensated pitot-static airspeed probes and application of the probes to supersonic cruise vehicles

    Science.gov (United States)

    Webb, L. D.; Washington, H. P.

    1972-01-01

    Static pressure position error calibrations for a compensated and an uncompensated XB-70 nose boom pitot static probe were obtained in flight. The methods (Pacer, acceleration-deceleration, and total temperature) used to obtain the position errors over a Mach number range from 0.5 to 3.0 and an altitude range from 25,000 feet to 70,000 feet are discussed. The error calibrations are compared with the position error determined from wind tunnel tests, theoretical analysis, and a standard NACA pitot static probe. Factors which influence position errors, such as angle of attack, Reynolds number, probe tip geometry, static orifice location, and probe shape, are discussed. Also included are examples showing how the uncertainties caused by position errors can affect the inlet controls and vertical altitude separation of a supersonic transport.

  18. Matching tomographic IMRT fields with static photon fields

    International Nuclear Information System (INIS)

    Sethi, A.; Leybovich, L.; Dogan, N.; Emami, B.

    2001-01-01

    The matching of abutting radiation fields presents a challenging problem in radiation therapy. Due to sharp penumbra of linear accelerator beams, small (1-2 mm) errors in field positioning can lead to large (>30%) hot or cold spots in the abutment region. With head and neck immobilization devices (thermoplastic mask/aquaplast) an average setup error of 3 mm has been reported. Therefore hot or cold spots approaching 50% of the prescription dose may occur along the matchline. Although abutting radiation fields have been investigated for static fields, there is no reported study regarding matching of tomographic IMRT and static fields. Compared to static fields, the matching of tomographic IMRT fields with static fields is more complicated. Since IMRT and static fields are planned on separate treatment planning computers, the dose in the abutment region is not specified. In addition, commonly used techniques for matching fields, such as feathering of junctions, are not practical. We have developed a method that substantially reduces dose inhomogeneity in the abutment region. In this method, a 'buffer zone' around the matchline was created and was included as part of the target for both IMRT and static field plans. In both fields, a small dose gradient (≤3%/mm) in the buffer zone was created. In the IMRT plan, the buffer zone was divided into three sections with dose varying from 83% to 25% of prescription dose. The static field dose profile was modified using either a specially designed physical (hard) or a dynamic (soft) wedge. When these modified fields were matched, the combined dose in the abutment region varied by ≤10% in the presence of setup errors spanning 4 mm (±2 mm) when the hard wedge was used and 10 mm (±5 mm) with the soft wedge

  19. The Effect of Two Kinds of Aerobic Exercise on the Static and Dynamic Balance of Old Men

    Directory of Open Access Journals (Sweden)

    Mojtaba Kashefi

    2014-07-01

    Full Text Available Objectives: The aim of present study is to determine the effect of two methods of aerobic training on static and dynamic balance in old men.  Methods & Materials: 37 aged people over 60 years old who were physically healthy divided into three groups after randomly carrying out pretest: 1 walking or running aerobic exercise group (n=12, 2 cycling aerobic exercise group (n=13 and 3 control group (n=12. Then groups 1 and 2, participated in running or walking exercise and cycling aerobic exercise as well with 60 percent of maximum heartbeat intensity. These two groups who were considered experimental groups of research appeared on exam site for 8 weeks, each week 3 sessions and each session 45 minutes. They rested one day between every two sessions of exercise. During the project group 3 (control continued its daily activities and had no especial exercise. After the training period, all subjects participated in the posttest session. In order to measure the static and dynamic balance Sharpend Romberg test and balancing timber test were used. The covariance analysis test (ANCOVA was also applied to examine the effect of exercise on the dependent variables and to study differences between group.  Results: The findings showed that exercise training programs in both experimental groups in research compared with control group significantly improved static and dynamic balance of subjects. It was also showed that the development of the first group (walking or running exercise group in both static and dynamic balance test was significantly higher than Group 2 (bike exercise group.  Conclusion: According to the results, it is recommended that trainers, organizations and institutions that deal with the elderly, use the cycling and walking exercises, especially walking and jogging to reduce the risk of further problem in these people.

  20. Static friction between silicon nanowires and elastomeric substrates.

    Science.gov (United States)

    Qin, Qingquan; Zhu, Yong

    2011-09-27

    This paper reports the first direct measurements of static friction force and interfacial shear strength between silicon (Si) nanowires (NWs) and poly(dimethylsiloxane) (PDMS). A micromanipulator is used to manipulate and deform the NWs under a high-magnification optical microscope in real time. The static friction force is measured based on "the most-bent state" of the NWs. The static friction and interface shear strength are found to depend on the ultraviolet/ozone (UVO) treatment of PDMS. The shear strength starts at 0.30 MPa without UVO treatment, increases rapidly up to 10.57 MPa at 60 min of treatment and decreases for longer treatment. Water contact angle measurements suggest that the UVO-induced hydrophobic-to-hydrophilic conversion of PDMS surface is responsible for the increase in the static friction, while the hydrophobic recovery effect contributes to the decrease. The static friction between NWs and PDMS is of critical relevance to many device applications of NWs including NW-based flexible/stretchable electronics, NW assembly and nanocomposites (e.g., supercapacitors). Our results will enable quantitative interface design and control for such applications. © 2011 American Chemical Society

  1. Mechanical performance of carbon-epoxy laminates. Part I: quasi-static and impact bending properties

    Directory of Open Access Journals (Sweden)

    José Ricardo Tarpani

    2006-06-01

    Full Text Available In Part I of this study, quasi-static and impact bending properties of four aeronautical grade carbon-epoxy laminates have been determined and compared. Materials tested were unidirectional cross-ply (tape and bidirectional woven textile (fabric carbon fiber lay-up architectures, impregnated with standard and rubber-toughened resins, respectively, giving rise to 1.5 mm-thick laminates. Quasi-static mechanical properties assessed in transversal mode loading were modulus of elasticity, flexural strength and tenacity at the maximum load, whereas the net absorbed energy was determined under translaminar impact conditions. Two-dimensional woven carbon fiber reinforcements embedded in a rubber-toughened matrix presented the best mechanical performance under static loading. Under dynamic loading conditions, woven fiber fabric pre-forms were favorably sensitive to increasing impact energies regardless the nature of the employed epoxy resin. However, it was concluded that great care should be taken with this material within the low energy impact regimen.

  2. Failure of composite plates under static biaxial planar loading

    Science.gov (United States)

    Waas, Anthony M.; Khamseh, Amir R.

    1992-01-01

    The project involved detailed investigations into the failure mechanisms in composite plates as a function of hole size (holes centrally located in the plates) under static loading. There were two phases to the project, the first dealing with uniaxial loads along the fiber direction, and the second dealing with coplanar biaxial loading. Results for the uniaxial tests have been reported and published previously, thus this report will place emphasis on the second phase of the project, namely the biaxial tests. The composite plates used in the biaxial loading experiments, as well as the uniaxial, were composed of a single ply unidirectional graphite/epoxy prepreg sandwiched between two layers of transparent thermoplastic. This setup enabled us to examine the failure initiation and propagation modes nondestructively, during the test. Currently, similar tests and analysis of results are in progress for graphite/epoxy cruciform shaped flat laminates. The results obtained from these tests will be available at a later time.

  3. The effect of time-of-day on static and dynamic balance in recreational athletes.

    Science.gov (United States)

    Heinbaugh, Erika M; Smith, Derek T; Zhu, Qin; Wilson, Margaret A; Dai, Boyi

    2015-09-01

    The purpose of this study was to investigate the effect of time-of-day (morning vs. afternoon) on static and dynamic balance in recreational athletes. A total of 34 recreational athletes completed the single-leg stance test with or without eyes open, lower quarter Y-balance test, upper quarter Y-balance test, and single-leg landing balance test in a random order in the morning (7:00-10:00 am) and afternoon (3:00-6:00 pm) for two consecutive days. Compared with the morning, participants demonstrated decreased centre of pressure (COP) sway areas (p = 0.002; Cohen's d (d) = 0.28) and sway speeds (p = 0.002; d = 0.17) during the eyes-open single-leg stance test, increased stance time (p = 0.031; d = 0.16) and decreased COP sway areas (p = 0.029; d = 0.22) during the eyes-closed single-leg stance test, and increased reaching distances (p = 0.024; d = 0.10) during the upper quarter Y-balance test in the afternoon. The between-day effect (day 1 vs. day 2) was observed for several parameters. Time-of-day had a minimal effect on dynamic balance and a noticeable effect on static balance. Time-of-day may be considered as a factor in designing balance training programmes and intervention studies for recreational athletes.

  4. Static aeroelastic analysis and tailoring of a single-element racing car wing

    Science.gov (United States)

    Sadd, Christopher James

    This thesis presents the research from an Engineering Doctorate research programme in collaboration with Reynard Motorsport Ltd, a manufacturer of racing cars. Racing car wing design has traditionally considered structures to be rigid. However, structures are never perfectly rigid and the interaction between aerodynamic loading and structural flexibility has a direct impact on aerodynamic performance. This interaction is often referred to as static aeroelasticity and the focus of this research has been the development of a computational static aeroelastic analysis method to improve the design of a single-element racing car wing. A static aeroelastic analysis method has been developed by coupling a Reynolds-Averaged Navier-Stokes CFD analysis method with a Finite Element structural analysis method using an iterative scheme. Development of this method has included assessment of CFD and Finite Element analysis methods and development of data transfer and mesh deflection methods. Experimental testing was also completed to further assess the computational analyses. The computational and experimental results show a good correlation and these studies have also shown that a Navier-Stokes static aeroelastic analysis of an isolated wing can be performed at an acceptable computational cost. The static aeroelastic analysis tool was used to assess methods of tailoring the structural flexibility of the wing to increase its aerodynamic performance. These tailoring methods were then used to produce two final wing designs to increase downforce and reduce drag respectively. At the average operating dynamic pressure of the racing car, the computational analysis predicts that the downforce-increasing wing has a downforce of C[1]=-1.377 in comparison to C[1]=-1.265 for the original wing. The computational analysis predicts that the drag-reducing wing has a drag of C[d]=0.115 in comparison to C[d]=0.143 for the original wing.

  5. Quasi-static Design of Electrically Small Ultra-Wideband Antennas

    Science.gov (United States)

    2017-02-01

    Equations. The ACD uses a constant line charge distribution and image line charge distribution (both on the -axis) to generate equipotential surfaces ...Each equipotential surface represents an ACD antenna design with a different height. In the Quasi-static Antenna Design Algorithm [2, 3, 4, 5, 6...quasi- static approximation used in the algorithm. A static charge distribution is used to generate equipotential surfaces . The equipotential surfaces

  6. Circular Raft Footings Strengthened by Stone Columns under Static Loads

    OpenAIRE

    R. Ziaie Moayed; B. Mohammadi-Haji

    2016-01-01

    Stone columns have been widely employed to improve the load-settlement characteristics of soft soils. The results of two small scale displacement control loading tests on stone columns were used in order to validate numerical finite element simulations. Additionally, a series of numerical calculations of static loading have been performed on strengthened raft footing to investigate the effects of using stone columns on bearing capacity of footings. The bearing capacity of single and group of ...

  7. SEU ground and flight data in static random access memories

    International Nuclear Information System (INIS)

    Liu, J.; Duan, J.L.; Hou, M.D.; Sun, Y.M.; Yao, H.J.; Mo, D.; Zhang, Q.X.; Wang, Z.G.; Jin, Y.F.; Cai, J.R.; Ye, Z.H.; Han, J.W.; Lin, Y.L.; Huang, Z.

    2006-01-01

    This paper presents the vulnerabilities of single event effects (SEEs) simulated by heavy ions on ground and observed on SJ-5 research satellite in space for static random access memories (SRAMs). A single event upset (SEU) prediction code has been used to estimate the proton-induced upset rates based on the ground test curve of SEU cross-section versus heavy ion linear energy transfer (LET). The result agrees with that of the flight data

  8. Static quarks with improved statistical precision

    International Nuclear Information System (INIS)

    Della Morte, M.; Duerr, S.; Molke, H.; Heitger, J.

    2003-09-01

    We present a numerical study for different discretisations of the static action, concerning cut-off effects and the growth of statistical errors with Euclidean time. An error reduction by an order of magnitude can be obtained with respect to the Eichten-Hill action, for time separations up to 2 fm, keeping discretization errors small. The best actions lead to a big improvement on the precision of the quark mass M b and F B s in the static approximation. (orig.)

  9. Acute effects of 15min static or contract-relax stretching modalities on plantar flexors neuromuscular properties.

    Science.gov (United States)

    Babault, Nicolas; Kouassi, Blah Y L; Desbrosses, Kevin

    2010-03-01

    The present study aimed to investigate the immediate effects of 15 min static or sub-maximal contract-relax stretching modalities on the neuromuscular properties of plantar flexor muscles. Ten male volunteers were tested before and immediately after 15 min static or contract-relax stretching programs of plantar flexor muscles (20 stretches). Static stretching consisted in 30s stretches to the point of discomfort. For the contract-relax stretching modality, subjects performed 6s sub-maximal isometric plantar flexion before 24s static stretches. Measurements included maximal voluntary isometric torque (MVT) and the corresponding electromyographic activity of soleus (SOL) and medial gastrocnemius (MG) muscles (RMS values), as well as maximal peak torque (Pt) elicited at rest by single supramaximal electrical stimulation of the tibial nerve. After 15 min stretching, significant MVT and SOL RMS decreases were obtained (-6.9+/-11.6% and -6.5+/-15.4%, respectively). No difference was obtained between stretching modalities. Pt remained unchanged after stretching. MG RMS changes were significantly different between stretching modalities (-9.4+/-18.3% and +3.5+/-11.6% after static and contract-relax stretching modalities, respectively). These findings indicated that performing 15 min static or contract-relax stretching had detrimental effects on the torque production capacity of plantar flexor muscles and should be precluded before competition. Mechanisms explaining this alteration seemed to be stretch modality dependent. Copyright 2009 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. Dynamic and quasi-static simulation and analysis of the plutonium oxide/metal containers subject to 30-foot dropping

    International Nuclear Information System (INIS)

    Gong, C.; Miller, R.F.

    1995-01-01

    This analysis of the plutonium oxide/metal storage containers is in support of the design and testing project The results from the dynamic analysis show some important facts that have not been considered before. The internal bagless transfer can will have higher stress than the primary container. The quasi-static analysis provides a conservative solution. In both vertical upright drop (dynamic) and inclined upside down drop (quasi-static) the containers are structurally sound

  11. Comparison of cardiovascular response to combined static-dynamic effort, postprandial dynamic effort and dynamic effort alone in patients with chronic ischemic heart disease

    International Nuclear Information System (INIS)

    Hung, J.; McKillip, J.; Savin, W.; Magder, S.; Kraus, R.; Houston, N.; Goris, M.; Haskell, W.; DeBusk, R.

    1982-01-01

    The cardiovascular responses to combined static-dynamic effort, postprandial dynamic effort and dynamic effort alone were evaluated by upright bicycle ergometry during equilibrium-gated blood pool scintigraphy in 24 men, mean age 59 +/- 8 years, with chronic ischemic heart disease. Combined static-dynamic effort and the postprandial state elicited a peak cardiovascular response similar to that of dynamic effort alone. Heart rate, intraarterial systolic and diastolic pressures, rate-pressure product and ejection fraction were similar for the three test conditions at the onset of ischemia and at peak effort. The prevalence and extent of exercise-induced ischemic left ventricular dysfunction, ST-segment depression, angina pectoris and ventricular ectopic activity were also similar during the three test conditions. Direct and indirect measurements of systolic and diastolic blood pressure were highly correlated. The onset of ischemic ST-segment depression and angina pectoris correlated as strongly with heart rate alone as with the rate-pressure product during all three test conditions. The cardiovascular response to combined static-dynamic effort and to postprandial dynamic effort becomes more similar to that of dynamic effort alone as dynamic effort reaches a symptom limit. If significant ischemic and arrhythmic abnormalities are absent during symptom-limited dynamic exercise testing, they are unlikely to appear during combined static-dynamic or postprandial dynamic effort

  12. Tools and Workflows for Collaborating on Static Website Projects

    Directory of Open Access Journals (Sweden)

    Kaitlin Newson

    2017-10-01

    Full Text Available Static website generators have seen a significant increase in popularity in recent years, offering many advantages over their dynamic counterparts. While these generators were typically used for blogs, they have grown in usage for other web-based projects, including documentation, conference websites, and image collections. However, because of their technical complexity, these tools can be inaccessible to content creators depending on their level of technical skill and comfort with web development technologies. Drawing from experience with a collaborative static website project, this article will provide an overview of static website generators, review different tools available for managing content, and explore workflows and best practices for collaborating with teams on static website projects.

  13. An easily implemented static condensation method for structural sensitivity analysis

    Science.gov (United States)

    Gangadharan, S. N.; Haftka, R. T.; Nikolaidis, E.

    1990-01-01

    A black-box approach to static condensation for sensitivity analysis is presented with illustrative examples of a cube and a car structure. The sensitivity of the structural response with respect to joint stiffness parameter is calculated using the direct method, forward-difference, and central-difference schemes. The efficiency of the various methods for identifying joint stiffness parameters from measured static deflections of these structures is compared. The results indicate that the use of static condensation can reduce computation times significantly and the black-box approach is only slightly less efficient than the standard implementation of static condensation. The ease of implementation of the black-box approach recommends it for use with general-purpose finite element codes that do not have a built-in facility for static condensation.

  14. Results of water corrosion in static cell tests representing multi-metal assemblies in the hydraulic circuits of Tore supra

    Energy Technology Data Exchange (ETDEWEB)

    Lipa, M. [CEA/DSM/DRFC Centre de Cadarache, 13 - Saint-Paul lez Durance (France); Blanchet, J.; Cellier, F. [Framatome, 71 - Saint Marcel (France). Centre Technique

    2007-07-01

    Following experiences obtained with steam generator tubes of nuclear power plants, a cooling water quality of AVT (all volatile treatment) has been defined based on demineralised water with adjustment of the pH value to about 9.0/7.0 (25 C/200 C) by addiction of ammoniac, and hydrazine in order to absorb oxygen dissolved in water. At that time, a simplified water corrosion test program has been performed using static (no circulation) test cell samples made of above mentioned TS metal combinations. All test cell samples, prepared and filled with AVT water, were performed at 280 C and 65 bars in an autoclave during 3000 hours. The test cell water temperature has been chosen to be sufficient above the TS component working temperature, in order to accelerate an eventual corrosion process. Generally all above mentioned metal combinations survived the test campaign without stress corrosion cracking, with the exception of the memory metal junction (creep in Cu) and the bellows made of St-St 316L and Inconel 625 while 316 Ti bellows survived. In contrary to the vacuum brazed Cu-LSTP to St-St samples, some of flame brazed Cu to St-St samples failed either in the braze joint or in the copper structure itself. For comparison, a spot weld of an inflated 316L panel sample, filled voluntary with a caustic solution of pH 11.5 (25 C), failed after 90 h of testing (intergranular cracking at the spot weld), while an identical sample containing AVT water of pH 9.0 (25 C) survived without damage. The results of these tests, performed during 1986 and 1997, have never been published and therefore are presented more in detail in this paper since corrosion in hydraulic circuits is also an issue of ITER. Up to day, the TS cooling water plant operates with an above mentioned water treatment and no water leaks have been detected on in-vessel components originating from water corrosion at high temperature and high pressure. (orig.)

  15. Results of water corrosion in static cell tests representing multi-metal assemblies in the hydraulic circuits of Tore supra

    International Nuclear Information System (INIS)

    Lipa, M.; Blanchet, J.; Cellier, F.

    2007-01-01

    Following experiences obtained with steam generator tubes of nuclear power plants, a cooling water quality of AVT (all volatile treatment) has been defined based on demineralised water with adjustment of the pH value to about 9.0/7.0 (25 C/200 C) by addiction of ammoniac, and hydrazine in order to absorb oxygen dissolved in water. At that time, a simplified water corrosion test program has been performed using static (no circulation) test cell samples made of above mentioned TS metal combinations. All test cell samples, prepared and filled with AVT water, were performed at 280 C and 65 bars in an autoclave during 3000 hours. The test cell water temperature has been chosen to be sufficient above the TS component working temperature, in order to accelerate an eventual corrosion process. Generally all above mentioned metal combinations survived the test campaign without stress corrosion cracking, with the exception of the memory metal junction (creep in Cu) and the bellows made of St-St 316L and Inconel 625 while 316 Ti bellows survived. In contrary to the vacuum brazed Cu-LSTP to St-St samples, some of flame brazed Cu to St-St samples failed either in the braze joint or in the copper structure itself. For comparison, a spot weld of an inflated 316L panel sample, filled voluntary with a caustic solution of pH 11.5 (25 C), failed after 90 h of testing (intergranular cracking at the spot weld), while an identical sample containing AVT water of pH 9.0 (25 C) survived without damage. The results of these tests, performed during 1986 and 1997, have never been published and therefore are presented more in detail in this paper since corrosion in hydraulic circuits is also an issue of ITER. Up to day, the TS cooling water plant operates with an above mentioned water treatment and no water leaks have been detected on in-vessel components originating from water corrosion at high temperature and high pressure. (orig.)

  16. Static Longitudinal and Lateral Stability and Control Data Obtained from Tests of a 1/15-Scale Model of the Goodyear XZP5K Airship, TED No. NACA DE 211

    Science.gov (United States)

    Cannon, Michael D.

    1956-01-01

    Static longitudinal and lateral stability and control data are presented of an investigation on a l/15-scale model of the Goodyear XZP5K airship over a pitch and yaw range of +/-20 deg and 0 deg to 30 deg, respectively, for various rudder and elevator deflections. Two tail configurations of different plan forms were tested and wake and boundary-layer surveys were conducted. Testing was conducted in the Langley full-scale tunnel at a Reynolds number of approximately 16.5 x 10(exp 6) based on hull length, and corresponds to a Mach number of about 0.12.

  17. de Sitter relativity in static charts

    Energy Technology Data Exchange (ETDEWEB)

    Cotaescu, Ion I. [West University of Timisoara, Timisoara (Romania)

    2018-02-15

    The relative geodesic motion in static (and spherically symmetric) local charts on the (1 + 3)-dimensional de Sitter spacetimes is studied in terms of conserved quantities. The Lorentzian isometries are derived, relating the coordinates of the local chart of a fixed observer with the coordinates of a mobile chart considered as the rest frame of a massive particle freely moving on a timelike geodesic. The time dilation and Lorentz contraction are discussed pointing out some notable features of the de Sitter relativity in static charts. (orig.)

  18. Comparison of Static Balance among Blind, Deaf and Normal Children in Different Conditions

    Directory of Open Access Journals (Sweden)

    Aidin Vali-Zadeh

    2014-01-01

    Full Text Available Objective: Sensory systems including proprioceptive, vestibular and visual network play an important role in motor control. Loss of information from each sensory channel can cause body sway on static positions. Materials & Methods: Seventeen blind children (9 girls, 8 boys and 30 deaf children (14 girls, 16 boys participated as the sample groups in Ardabil city. Sixteen normal children (30 girls and 30 boys also selected as the control group. One leg standing and tandem stance tests (reliability=0.87-0.99 in two condition (eyes open and closed was used for static balance evaluation. One-Way ANOVA and LSD post hoc test was used to compare groups, and independent t-test was used for comparing sexes in each group by using SPSS (16 version software. Results: results showed there is no significant difference between blind, deaf and normal girls in any of the balance tasks (p>0.05. While the balance function of deaf and normal boys was better than blind boys in all balance tasks except for tandem stance with eyes closed (p=0.507. Blind girls were better than blind boys in all balance tasks (p=0.05, p=0.02, p=0.02. Deaf boys were better than girls with deafness in one leg stance and tandem stance (eyes open tasks (p=0.04, p=0.02, p=0.04 but there was no significant different between deaf boys and girls in any other tasks (p=0.63, p=0.29, p=0.89. Normal boys have better performance than girls and only in tandem stance (eyes closed (p=0.21 and one leg stance (left foot eyes open (p=0.99 there was no significant difference between normal boys and girls. Conclusion: findings showed that static balance in deaf and normal children were better than the blinds. Since persons with blindness are not able to compensate the visual loss for postural stability, they show decreased postural stability in static conditions. Inclusive identifying effective factors on balance and its weakness and problems in appropriate time, attention to this factors in training

  19. Survey of approaches for handling static analysis alarms

    NARCIS (Netherlands)

    Muske, T.; Serebrenik, A.

    2016-01-01

    Static analysis tools have showcased their importance and usefulness in automated detection of code anomalies and defects. However, the large number of alarms reported and cost incurred in their manual inspections have been the major concerns with the usage of static analysis tools. Existing studies

  20. Multiple histogram method and static Monte Carlo sampling

    NARCIS (Netherlands)

    Inda, M.A.; Frenkel, D.

    2004-01-01

    We describe an approach to use multiple-histogram methods in combination with static, biased Monte Carlo simulations. To illustrate this, we computed the force-extension curve of an athermal polymer from multiple histograms constructed in a series of static Rosenbluth Monte Carlo simulations. From

  1. Reliability and reference values of two clinical measurements of dynamic and static knee position in healthy children

    DEFF Research Database (Denmark)

    Ortqvist, Maria; Moström, Eva B; Roos, Ewa M.

    2011-01-01

    PURPOSE: The purposes of this study were to evaluate reliability of the Single-limb mini squat test (a dynamic measure of medio-lateral knee position) and the Quadriceps-angle (Q-angle) (a static measure of medio-lateral knee position), present paediatric reference values of the Q......-angle measurements was found. Reference values for the Q-angle (mean 13.5° (1.9)-15.3° (2.8)) varies with age and gender. No associations were found between dynamic and static measures. CONCLUSIONS: The Single-limb mini squat test showed a moderate reliability and the Q-angle showed a fair to moderate reliability......-angle, and evaluate the association between the tests. METHODS: Two hundred and forty-six healthy children (9-16 years) were included (intra/inter-rater reliability for Q-angle (n = 37/85) and for Single-limb mini squat test (n = 33/28)). Dynamic medio-lateral knee position was assessed by the Single-limb mini squat...

  2. Processes influencing migration of bioavailable organic compounds from polymers - investigated during biotic and abiotic testing under static and non-static conditions with varying S/V-ratios

    DEFF Research Database (Denmark)

    Corfitzen, Charlotte B.; Arvin, Erik; Albrechtsen, Hans-Jørgen

    . The bioavailable migration from the polymer surface was influence by diffusion over the solid-liquid boundary layer under sterile conditions, which resulted in an inversely proportionally relationship between bioavailable migration expressed per unit surface area of material and the surface to volume ratio (S/V-ratio...... the effect of the boundary layer, since bioavailable migration was continuously consumed by the bacteria. Thus the driving force for the diffusion process was maintained at a maximum, thereby enhancing the bioavailable migration from the material surfaces. Thus neither non-static conditions nor varying S/V-ratios...

  3. Fast static field CIPT mapping of unpatterned MRAM film stacks

    DEFF Research Database (Denmark)

    Kjær, Daniel; Hansen, Ole; Henrichsen, Henrik Hartmann

    2015-01-01

    Current In-Plane Tunneling (CIPT) method measures both RA and TMR, but the usefulness for uniformity mapping, e.g. for tool optimization, is limited by excessive measurement time. Thus, we develop and demonstrate a fast complementary static magnetic field method focused only on measurement of RA. We...... compare the static field method to the standard CIPT method and find perfect agreement between the extracted RA values and measurement repeatability while the static field method is several times faster. The static field CIPT method is demonstrated for 200 mm wafer mapping showing radial as well...

  4. From Flow Logic to static type systems for coordination languages

    DEFF Research Database (Denmark)

    De Nicola, Rocco; Gorla, Daniele; Hansen, Rene Rydhof

    2010-01-01

    checks; therefore, the correctness properties cannot be statically enforced. By contrast, static analysis approaches based on Flow Logic usually guarantee properties statically. In this paper, we show how the insights from the Flow Logic approach can be used to construct a type system for statically......Coordination languages are often used to describe open-ended systems. This makes it challenging to develop tools for guaranteeing the security of the coordinated systems and the correctness of their interaction. Successful approaches to this problem have been based on type systems with dynamic...

  5. From Flow Logic to Static Type Systems in Coordination Languages

    DEFF Research Database (Denmark)

    De Nicola, Rocco; Gorla, Daniele; Hansen, René Rydhof

    2008-01-01

    ; therefore, the correctness properties cannot be statically enforced. By contrast, static analysis approaches based on Flow Logic usually guarantee properties statically. In this paper we show how to combine these two approaches to obtain a static type system for describing secure access to tuple spaces......Coordination languages are often used to describe open ended systems. This makes it challenging to develop tools for guaranteeing security of the coordinated systems and correctness of their interaction. Successful approaches to this problem have been based on type systems with dynamic checks...

  6. Miniature Flow-Direction/Pitot-Static Pressure Probes

    Science.gov (United States)

    Ashby, George C., Jr.; Coombs, David S.; Eves, John W.; Price, Howard E.; Vasquez, Peter

    1989-01-01

    Precision flow-direction/pitot-static pressure probes, ranging from 0.035 to 0.090 inch (0.89 to 2.29 mm) in outside diameter, successfully fabricated and calibrated for use in Langley 20-inch Mach 6 Tunnel. Probes simultaneously measure flow direction and static and pitot pressures in flow fields about configurations in hypersonic flow at temperatures up to 500 degree F (260 degree C).

  7. Water cooled static pressure probe

    Science.gov (United States)

    Lagen, Nicholas T. (Inventor); Eves, John W. (Inventor); Reece, Garland D. (Inventor); Geissinger, Steve L. (Inventor)

    1991-01-01

    An improved static pressure probe containing a water cooling mechanism is disclosed. This probe has a hollow interior containing a central coolant tube and multiple individual pressure measurement tubes connected to holes placed on the exterior. Coolant from the central tube symmetrically immerses the interior of the probe, allowing it to sustain high temperature (in the region of 2500 F) supersonic jet flow indefinitely, while still recording accurate pressure data. The coolant exits the probe body by way of a reservoir attached to the aft of the probe. The pressure measurement tubes are joined to a single, larger manifold in the reservoir. This manifold is attached to a pressure transducer that records the average static pressure.

  8. The sky is falling III: The effect of deposition from static solid rocket motor tests on juvenile crops.

    Science.gov (United States)

    Doucette, William J; Curry, Eric; McNeill, Laurie S; Heavilin, Justin

    2017-12-01

    A mixture of combustion products (mainly hydrogen chloride, aluminum oxide, and water) and entrained soil, referred to as Test Fire Soil (TFS), can be deposited on crops during static solid rocket motor tests. The impact of a reported worst-case event was previously evaluated by exposing corn and alfalfa to 3200-gTFS/m 2 at 54days after emergence. Exposures via soil and leaves were evaluated separately. Reduced growth (soil exposure) and leaf "scorch" (leaf exposure) were attributed mainly to the high chloride concentrations in the TFS (56,000mg/kg). A follow-up study was conducted to evaluate the effect of a typical deposition event (70-gTFS/m 2 , estimated by radar during several tests) and exposure (soil and leaves simultaneously) on juvenile corn, alfalfa, and winter wheat. Younger crops were used to examine potential age sensitivity differences. Impact was evaluated by comparing the growth, elemental composition, and leaf chlorophyll content of treated and untreated plants. The relationship between deposition exposure and response was also addressed. Growth of corn, alfalfa, and winter wheat exposed to a typical TFS loading was not impacted, although slightly elevated concentrations of aluminum and iron were found in the leaves. At the highest loadings used for the exposure-response experiment, concentrations of chloride and calcium were higher in TFS-exposed corn leaves than in the untreated leaves. Overall results indicate that exposure to a typical deposition event does not adversely impact juvenile crops and that younger plants may be less vulnerable to TFS. However, higher TFS loadings can cause leaf scorch and increase the leaf concentrations of some elements. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Non-static vacuum strings: exterior and interior solutions

    International Nuclear Information System (INIS)

    Stein-Schabes, J.A.

    1986-01-01

    New non-static cylindrically symmetric solutions of Einsteins's equations are presented. Some of these solutions represent string-like objects. An exterior vacuum solution is matched to a non-vacuum interior solution for different forms of the energy-momentum tensor. They generalize the standard static string. 12 refs

  10. Passive elimination of static electricity in oil industry

    Directory of Open Access Journals (Sweden)

    Gaćanović Mićo

    2014-01-01

    Full Text Available This study explains the existing and real conditions of a possible passive elimination of static electricity when loading oil and oil derivatives. We are considering the formation and survival of gas bubbles both in the volume of oil in its depth, but also at the surface of oil and oil derivatives of the partly filled reservoir, and formation of both volume and surface electric charge in oil and oil derivatives. The study presents the research of formation and survival of static electricity in both reservoirs and tank trucks of different geometric shapes partly filled with oil and oil derivatives. We are proposing a new original possibility of passive elimination of static electricity when loading oil and oil derivatives in reservoirs and tank trucks. The proposed passive device for elimination of static electricity is protected at the international level in the domain of intellectual property (with a patent, model and distinctive mark.

  11. Effect of microstructure on static and dynamic mechanical properties of high strength steels

    Science.gov (United States)

    Qu, Jinbo

    The high speed deformation behavior of a commercially available dual phase (DP) steel was studied by means of split Hopkinson bar apparatus in shear punch (25m/s) and tension (1000s-1) modes with an emphasis on the influence of microstructure. The cold rolled sheet material was subjected to a variety of heat treatment conditions to produce several different microstructures, namely ferrite plus pearlite, ferrite plus bainite and/or acicular ferrite, ferrite plus bainite and martensite, and ferrite plus different fractions of martensite. Static properties (0.01mm/s for shear punch and 0.001s -1 for tension) of all the microstructures were also measured by an MTS hydraulic machine and compared to the dynamic properties. The effects of low temperature tempering and bake hardening were investigated for some ferrite plus martensite microstructures. In addition, two other materials, composition designed as high strength low alloy (HSLA) steel and transformation induced plasticity (TRIP) steel, were heat treated and tested to study the effect of alloy chemistry on the microstructure and property relationship. A strong effect of microstructure on both static and dynamic properties and on the relationship between static and dynamic properties was observed. According to the variation of dynamic factor with static strength, three groups of microstructures with three distinct behaviors were identified, i.e. classic dual phase (ferrite plus less than 50% martensite), martensite-matrix dual phase (ferrite plus more than 50% martensite), and non-dual phase (ferrite plus non-martensite). Under the same static strength level, the dual phase microstructure was found to absorb more dynamic energy than other microstructures. It was also observed that the general dependence of microstructure on static and dynamic property relationship was not strongly influenced by chemical composition, except the ferrite plus martensite microstructures generated by the TRIP chemistry, which exhibited

  12. Static structure of active Brownian hard disks

    Science.gov (United States)

    de Macedo Biniossek, N.; Löwen, H.; Voigtmann, Th; Smallenburg, F.

    2018-02-01

    We explore the changes in static structure of a two-dimensional system of active Brownian particles (ABP) with hard-disk interactions, using event-driven Brownian dynamics simulations. In particular, the effect of the self-propulsion velocity and the rotational diffusivity on the orientationally-averaged fluid structure factor is discussed. Typically activity increases structural ordering and generates a structure factor peak at zero wave vector which is a precursor of motility-induced phase separation. Our results provide reference data to test future statistical theories for the fluid structure of active Brownian systems. This manuscript was submitted for the special issue of the Journal of Physics: Condensed Matter associated with the Liquid Matter Conference 2017.

  13. Static analysis of an office desk construction

    Directory of Open Access Journals (Sweden)

    Milan Novotný

    2011-01-01

    Full Text Available The objective of the paper is a static analysis of a desk construction and the determination of its probable mechanical behaviour using Finite Element Method. The construction was modelled and numerically analysed in Autocad Inventor 2011 and the stability of the entire desk was calculated with the size and placement of the loading force based on the standards and cited literature. Possible locations and directions of the deformation were analysed and a solution for its prevention was proposed and the stability of the desk as well as the extreme position of the stand were calculated. The verification of the obtained results in an accredited furniture testing lab is planned using a prototype of the office desk.

  14. Extending and Enhancing SAS (Static Analysis Suite)

    CERN Document Server

    Ho, David

    2016-01-01

    The Static Analysis Suite (SAS) is an open-source software package used to perform static analysis on C and C++ code, helping to ensure safety, readability and maintainability. In this Summer Student project, SAS was enhanced to improve ease of use and user customisation. A straightforward method of integrating static analysis into a project at compilation time was provided using the automated build tool CMake. The process of adding checkers to the suite was streamlined and simplied by developing an automatic code generator. To make SAS more suitable for continuous integration, a reporting mechanism summarising results was added. This suitability has been demonstrated by inclusion of SAS in the Future Circular Collider Software nightly build system. Scalability of the improved package was demonstrated by using the tool to analyse the ROOT code base.

  15. Static and fatigue investigation of second generation steel free bridge decks

    International Nuclear Information System (INIS)

    Klowak, C.; Memon, Amjad H.; Mufti, Aftab A.

    2006-01-01

    This paper outlines the static and fatigue behavior of two different cast-in-place second generation steel-free bridge decks, which are: hybrid carbon fiber reinforced polymer (CFRP); and glass fiber reinforced polymer (GFRP) and steel strap design. Although cast monolithically, the first deck slab was divided into three segments with different reinforcement configurations. All three segments were tested under a 222kN cyclic loading to investigate fatigue behavior. The second bridge deck comprised an internal panel and two cantilevers and was equipped with a civionics system. The internal panel static test that this paper deals with is useful in the development of fatigue theory derived from fatigue testing of the first bridge deck. Test results form the cyclic loading of the first bridge deck indicated that the cross-sectional area of the reinforcement used in the test bridge deck can be reduced by 40% based on the reinforcement provided in the deck under service loads. The hybrid system also reduced the development of longitudinal crack widths to approximately 0.4 mm under service conditions, compared to the cracks that occurred approximately halfway between adjacent bridge girders that were determined to be roughly 1 mm in several first generation steel-free bridge decks constructed in Canada. Civionics, also discussed in the paper, is a new term coined from Civil-Electronics, which is the application of electronics to civil structures. The Civionics Specifications (2004) developed by ISIS Canada researchers are a helpful design tool for engineers and contractors to develop civionics and structural health monitoring systems for civil infrastructure that will last the lifetime of a structure. The use of civionics for the second test bridge deck ensured the survival of 100% of the 63 internal sensors throughout the rigors of the construction and casting of the deck. (author)

  16. Einstein's conversion from his static to an expanding universe

    Science.gov (United States)

    Nussbaumer, Harry

    2014-02-01

    In 1917 Einstein initiated modern cosmology by postulating, based on general relativity, a homogenous, static, spatially curved universe. To counteract gravitational contraction he introduced the cosmological constant. In 1922 Alexander Friedman showed that Albert Einstein's fundamental equations also allow dynamical worlds, and in 1927 Georges Lemaître, backed by observational evidence, concluded that our universe was expanding. Einstein impetuously rejected Friedman's as well as Lemaître's findings. However, in 1931 he retracted his former static model in favour of a dynamic solution. This investigation follows Einstein on his hesitating path from a static to the expanding universe. Contrary to an often advocated belief the primary motive for his switch was not observational evidence, but the realisation that his static model was unstable.

  17. Static compensators (STATCOMs) in power systems

    CERN Document Server

    Shahnia, Farhad; Ghosh, Arindam

    2014-01-01

    A static compensator (STATCOM), also known as static synchronous compensator, is a member of the flexible alternating current transmission system (FACTS) devices. It is a power-electronics based regulating device which is composed of a voltage source converter (VSC) and is shunt-connected to alternating current electricity transmission and distribution networks. The voltage source is created from a DC capacitor and the STATCOM can exchange reactive power with the network. It can also supply some active power to the network, if a DC source of power is connected across the capacitor. A STATCOM

  18. Comparison of pressure perception of static and dynamic two point ...

    African Journals Online (AJOL)

    ... the right and left index finger (p<0.05). Conclusion: Age and gender did not affect the perception of static and dynamic two point discrimination while the limb side (left or right) affected the perception of static and dynamic two point discrimination. The index finger is also more sensitive to moving rather static sensations.

  19. Enhancement of sedimentation and coagulation with static magnetic field

    Science.gov (United States)

    Zieliński, Marcin; Dębowski, Marcin; Hajduk, Anna; Rusanowska, Paulina

    2017-11-01

    The static magnetic field can be an alternative method for wastewater treatment. It has been proved that this physical factor, accelerates the biochemical processes, catalyzes advanced oxidation, intensifies anaerobic and aerobic processes or reduces swelling of activated sludge. There are also reports proving the positive impact of the static magnetic field on the coagulation and sedimentation, as well as the conditioning and dewatering of sludge. In order to be applied in larger scale the published results should be verified and confirmed. In the studies, the enhancement of sedimentation by the static magnetic field was observed. The best sedimentation was noted in the experiment, where magnetizers were placed on activated sludge bioreactor and secondary settling tank. No effect of the static magnetic field on coagulation with the utilization of PIX 113 was observed. However, the static magnetic field enhanced coagulation with the utilization of PAX-XL9. The results suggest that increased sedimentation of colloids and activated sludge, can in practice mean a reduction in the size of the necessary equipment for sedimentation with an unchanged efficiency of the process.

  20. Hydrogen generation through static-feed water electrolysis

    Science.gov (United States)

    Jensen, F. C.; Schubert, F. H.

    1975-01-01

    A static-feed water electrolysis system (SFWES), developed under NASA sponsorship, is presented for potential applicability to terrestrial hydrogen production. The SFWES concept uses (1) an alkaline electrolyte to minimize power requirements and materials-compatibility problems, (2) a method where the electrolyte is retained in a thin porous matrix eliminating bulk electrolyte, and (3) a static water-feed mechanism to prevent electrode and electrolyte contamination and to promote system simplicity.

  1. Heterogeneous patterns enhancing static and dynamic texture classification

    International Nuclear Information System (INIS)

    Silva, Núbia Rosa da; Martinez Bruno, Odemir

    2013-01-01

    Some mixtures, such as colloids like milk, blood, and gelatin, have homogeneous appearance when viewed with the naked eye, however, to observe them at the nanoscale is possible to understand the heterogeneity of its components. The same phenomenon can occur in pattern recognition in which it is possible to see heterogeneous patterns in texture images. However, current methods of texture analysis can not adequately describe such heterogeneous patterns. Common methods used by researchers analyse the image information in a global way, taking all its features in an integrated manner. Furthermore, multi-scale analysis verifies the patterns at different scales, but still preserving the homogeneous analysis. On the other hand various methods use textons to represent the texture, breaking texture down into its smallest unit. To tackle this problem, we propose a method to identify texture patterns not small as textons at distinct scales enhancing the separability among different types of texture. We find sub patterns of texture according to the scale and then group similar patterns for a more refined analysis. Tests were performed in four static texture databases and one dynamical one. Results show that our method provide better classification rate compared with conventional approaches both in static and in dynamic texture.

  2. Order parameters in the Landau–de Gennes theory – the static and dynamic scenarios

    KAUST Repository

    Majumdar, Apala

    2011-02-17

    We obtain quantitative estimates for the scalar order parameters of liquid crystal configurations in three-dimensional geometries, within the Landau-de Gennes framework. We consider both static equilibria and non-equilibrium dynamics and we include external fields and surface anchoring energies in our formulation. Using maximum principle-type arguments, we obtain explicit bounds for the corresponding scalar order parameters in both static and dynamic situations; these bounds are given in terms of the material-dependent thermotropic coefficients, electric field strength and surface anchoring coefficients. These bounds provide estimates for the degree of orientational ordering, quantify the competing effects of the different energetic contributions and can be used to test the accuracy of numerical simulations. © 2011 Taylor & Francis.

  3. Order parameters in the Landau–de Gennes theory – the static and dynamic scenarios

    KAUST Repository

    Majumdar, Apala

    2011-01-01

    We obtain quantitative estimates for the scalar order parameters of liquid crystal configurations in three-dimensional geometries, within the Landau-de Gennes framework. We consider both static equilibria and non-equilibrium dynamics and we include external fields and surface anchoring energies in our formulation. Using maximum principle-type arguments, we obtain explicit bounds for the corresponding scalar order parameters in both static and dynamic situations; these bounds are given in terms of the material-dependent thermotropic coefficients, electric field strength and surface anchoring coefficients. These bounds provide estimates for the degree of orientational ordering, quantify the competing effects of the different energetic contributions and can be used to test the accuracy of numerical simulations. © 2011 Taylor & Francis.

  4. Relations between Biomechanical Parameters and Static Power of Arms in Children with Disturbed Posture

    Directory of Open Access Journals (Sweden)

    Slobodan Andrašić

    2017-02-01

    Full Text Available This study is aimed at determining the parameters and biomechanical analysis of their impact on the static arm strength in children with impaired posture as poor kyphotic posture, lordotic poor posture and children with flat feet. A transversal study included a sample of 67 children on the territory of the municipality of Subotica. The structure of the sample is as follows: 22 subjects with impaired kyphotic posture, 18 patients with impaired lordotic posture, and 27 subjects with flat feet. Measuring the level of static arm strength was done by the standardized "folding endurance" test. Observing the morphological development of children with kyphotic, lordotic poor posture and flat feet determined statistically significant differences in biomechanical variables.

  5. Static and Dynamic Path Planning Using Incremental Heuristic Search

    OpenAIRE

    Khattab, Asem

    2018-01-01

    Path planning is an important component in any highly automated vehicle system. In this report, the general problem of path planning is considered first in partially known static environments where only static obstacles are present but the layout of the environment is changing as the agent acquires new information. Attention is then given to the problem of path planning in dynamic environments where there are moving obstacles in addition to the static ones. Specifically, a 2D car-like agent t...

  6. Cardiovascular responses to static exercise in distance runners and weight lifters

    Science.gov (United States)

    Longhurst, J. C.; Kelly, A. R.; Gonyea, W. J.; Mitchell, J. H.

    1980-01-01

    Three groups of athletes including long-distance runners, competitive and amateur weight lifters, and age- and sex-matched control subjects have been studied by hemodynamic and echocardiographic methods in order to determine the effect of the training programs on the cardiovascular response to static exercise. Blood pressure, heart rate, and double product data at rest and at fatigue suggest that competitive endurance (dynamic exercise) training alters the cardiovascular response to static exercise. In contrast to endurance exercise, weight lifting (static exercise) training does not alter the cardiovascular response to static exercise: weight lifters responded to static exercise in a manner very similar to that of the control subjects.

  7. Effects of Water-Based Training on Static and Dynamic Balance of Older Women.

    Science.gov (United States)

    Bento, Paulo Cesar Barauce; Lopes, Maria de Fátima A; Cebolla, Elaine Cristine; Wolf, Renata; Rodacki, André L F

    2015-08-01

    The aim of this study was to evaluate the effects of a water-based exercise program on static and dynamic balance. Thirty-six older women were randomly assigned to a water-based training (3 days/week for 12 weeks) or control group. Water level was kept at the level of the xiphoid process and temperature at ∼28-30°C. Each session included aerobic activities and lower limb strength exercises. The medial-lateral, the anterior-posterior amplitude, and displacement of the center of pressure (CP-D) were measured in a quiet standing position (60 sec eyes opened and closed). The dynamic balance and 8-Foot Up-and-Go tests were also applied. Group comparisons were made using two-way analysis of variance (ANOVA) with repeated measures. No differences were found in the center of pressure variables; however, the WBT group showed better performance in the 8 Foot Up-and-Go Test after training (5.61±0.76 vs. 5.18±0.42; pwater-based training was effective in improving dynamic balance, but not static balance.

  8. Static Friction Phenomena in Granular Materials: Coulomb Law vs. Particle Geometry

    OpenAIRE

    Poeschel, T.; Buchholtz, V.

    1993-01-01

    The static as well as the dynamic behaviour of granular material are determined by dynamic {\\it and} static friction. There are well known methods to include static friction in molecular dynamics simulations using scarcely understood forces. We propose an Ansatz based on the geometrical shape of nonspherical particles which does not involve an explicit expression for static friction. It is shown that the simulations based on this model are close to experimental results.

  9. Explosions and static electricity

    DEFF Research Database (Denmark)

    Jonassen, Niels M

    1995-01-01

    The paper deals with the problem of electrostatic discharges as causes of ignition of vapor/gas and dust/gas mixtures. A series of examples of static-caused explosions will be discussed. The concepts of explosion limits, the incendiveness of various discharge types and safe voltages are explained...

  10. Determinacy in Static Analysis of jQuery

    DEFF Research Database (Denmark)

    Andreasen, Esben; Møller, Anders

    2014-01-01

    Static analysis for JavaScript can potentially help programmers find errors early during development. Although much progress has been made on analysis techniques, a major obstacle is the prevalence of libraries, in particular jQuery, which apply programming patterns that have detrimental conseque......Static analysis for JavaScript can potentially help programmers find errors early during development. Although much progress has been made on analysis techniques, a major obstacle is the prevalence of libraries, in particular jQuery, which apply programming patterns that have detrimental...... present a static dataflow analysis for JavaScript that infers and exploits determinacy information on-the-fly, to enable analysis of some of the most complex parts of jQuery. The techniques are implemented in the TAJS analysis tool and evaluated on a collection of small programs that use jQuery. Our...

  11. Quasi-Static Electric Field Generator

    Science.gov (United States)

    Generazio, Edward R. (Inventor)

    2017-01-01

    A generator for producing an electric field for with an inspection technology system is provided. The generator provides the required variable magnitude quasi-static electric fields for the "illumination" of objects, areas and volumes to be inspected by the system, and produces human-safe electric fields that are only visible to the system. The generator includes a casing, a driven, non-conducting and triboelectrically neutral rotation shaft mounted therein, an ungrounded electrostatic dipole element which works in the quasi-static range, and a non-conducting support for mounting the dipole element to the shaft. The dipole element has a wireless motor system and a charging system which are wholly contained within the dipole element and the support that uses an electrostatic approach to charge the dipole element.

  12. Comparison of Static Balance and the Role of Vision in Elite Athletes

    Directory of Open Access Journals (Sweden)

    Hammami Raouf

    2014-07-01

    Full Text Available When prescribing balance exercises to athletes in different sports, it may be important to recognize performance variations. Indeed, how athletes from different sports perform on balance tests is not well understood. The goal of the present study was to compare static balance and the role of vision among elite sprinters, jumpers and rugby players. The modified clinical test of sensory interaction on balance (mCTSIB was used to assess the velocity of the center-of-pressure (CoP on a force platform during a 30 s bipedal quiet standing posture in 4 conditions: firm surface with opened and closed eyes, foam surface with opened and closed eyes. Three-factor ANOVA indicated a significant main effect for groups (F=21.69, df=2, p0.05. The nature of the sport practiced and the absence of visual control are linked to modify static balance in elite athletes. Coaches and strength and conditioning professionals are recommended to use a variety of exercises to improve balance, including both exercises with opened and closed eyes on progressively challenging surfaces in order to make decisions about tasks and sensory availability during assessment and training.

  13. Static and kinematic positioning using WADGPS from geostationary satellites

    Science.gov (United States)

    Cefalo, R.; Gatti, M.

    2003-04-01

    STATIC AND KINEMATIC POSITIONING USING WADGPS CORRECTIONS FROM GEOSTATIONARY SATELLITES Cefalo R. (1), Gatti M (2) (1) Department of Civil Engineering, University of Trieste, P.le Europa 1, 34127 Trieste, Italy, cefalo@dic.univ.trieste.it, (2) Department of Engineering, University of Ferrara, via Saragat 1, 44100 Ferrara, Italy, mgatti@ing.unife.it ABSTRACT. Starting from February 2000, static and kinematic experiments have been performed at the Department of Civil Engineering of University of Trieste, Italy and the Department of Engineering of University of Ferrara, Italy, using the WADGPS (Wide Area Differential GPS) corrections up linked by Geostationary Satellites belonging to the American WAAS and European EGNOS. Recently, a prototypal service by ESA (European Space Agency) named SISNet (Signal In Space through Internet), has been introduced using Internet to diffuse the messages up linked through AOR-E and IOR Geostationary Satellites. This service will overcome the problems relative to the availability of the corrections in urban areas. This system is currently under tests by the authors in order to verify the latency of the message and the applicability and accuracies obtainable in particular in dynamic applications.

  14. Static postural balance in healthy individuals: Comparisons between three age groups

    Directory of Open Access Journals (Sweden)

    Yanne Salviano Pereira

    2014-03-01

    Full Text Available The aim of the study was to compare static postural balance of healthy individuals of three age groups in different conditions of support and vision. Seventy one individuals, divided into 3 groups, were analyzed: young group (YG: 22.2 ± 2.1 years, middle aged group (MAG: 50.7 ± 5.7 years and older individuals group (EG: 66.8 ± 5.4 years. Their balance was tested on a force platform, under 3 support and 3 visual conditions. Measures included: total (TD, anterior-posterior (APD and mediolateral displacement (MLD of the center of pressure (CoP. ANOVA revealed significant differences for interactions between group X support conditions and group X visual conditions for the 3 variables (p<0.01, with greater displacements for the MAG and EG groups during single-leg stance with partial and occluded vision (p<0.05. Static postural balance decreased over time in healthy individuals, and conditions of support and visual negatively affected balance with the increment of age.

  15. Effects of a static electric field on nonsequential double ionization

    International Nuclear Information System (INIS)

    Li Hongyun; Wang Bingbing; Li Xiaofeng; Fu Panming; Chen Jing; Liu Jie; Jiang Hongbing; Gong Qihuang; Yan Zongchao

    2007-01-01

    Using a three-dimensional semiclassical method, we perform a systematic analysis of the effects of an additional static electric field on nonsequential double ionization (NSDI) of a helium atom in an intense, linearly polarized laser field. It is found that the static electric field influences not only the ionization rate, but also the kinetic energy of the ionized electron returning to the parent ion, in such a way that, if the rate is increased, then the kinetic energy of the first returning electron is decreased, and vice versa. These two effects compete in NSDI. Since the effect of the static electric field on the ionization of the first electron plays a more crucial role in the competition, the symmetric double-peak structure of the He 2+ momentum distribution parallel to the polarization of the laser field is destroyed. Furthermore, the contribution of the trajectories with multiple recollisions to the NSDI is also changed dramatically by the static electric field. As the static electric field increases, the trajectories with two recollisions, which start at the time when the laser and the static electric field are in the same direction, become increasingly important for the NSDI

  16. Comparison of the quasi-static method and the dynamic method for simulating fracture processes in concrete

    Science.gov (United States)

    Liu, J. X.; Deng, S. C.; Liang, N. G.

    2008-02-01

    Concrete is heterogeneous and usually described as a three-phase material, where matrix, aggregate and interface are distinguished. To take this heterogeneity into consideration, the Generalized Beam (GB) lattice model is adopted. The GB lattice model is much more computationally efficient than the beam lattice model. Numerical procedures of both quasi-static method and dynamic method are developed to simulate fracture processes in uniaxial tensile tests conducted on a concrete panel. Cases of different loading rates are compared with the quasi-static case. It is found that the inertia effect due to load increasing becomes less important and can be ignored with the loading rate decreasing, but the inertia effect due to unstable crack propagation remains considerable no matter how low the loading rate is. Therefore, an unrealistic result will be obtained if a fracture process including unstable cracking is simulated by the quasi-static procedure.

  17. Static measurements at PUSPATI TRIGA Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Syed Nahar Bin Syed Hussin Shabuddin; Sharifuldin Bin Salleh, Mohd Amin; Harasawa, Susumu

    1985-06-01

    Static measurements at the PUSPATI TRIGA Reactor (RTP) were made to study the variation of its fuel temperature with reactor power. Some constants that relate power to fuel temperature behaviour were also determined. These constants are reflective of the coolling characteristics in the reactor core. Comparison was also made between the negative temperature coefficient of reactivity obtained from these measurements to those published in the Safety Analysis Report, SAR. The differences between these values are attributable to a delayed effect found in static measurements but not included in the SAR calculation which consider the prompt effect only.

  18. Immediate effects of cryotherapy on static and dynamic balance.

    Science.gov (United States)

    Douglas, Matthew; Bivens, Serena; Pesterfield, Jennifer; Clemson, Nathan; Castle, Whitney; Sole, Gisela; Wassinger, Craig A

    2013-02-01

    Cryotherapy is commonly used in physical therapy with many known benefits; however several investigations have reported decreased functional performance following therapeutic application thereof. The purpose of this study was to determine the effect of cryotherapy applied to the ankle on static and dynamic standing balance. It was hypothesized that balance would be decreased after cryotherapy application. Twenty individuals (aged 18 to 40 years) participated in this research project. Each participant was tested under two conditions: an experimental condition where subjects received ice water immersion of the foot and ankle for 15 minutes immediately before balance testing and a control condition completed at room temperature. A Biodex® Balance System was used to quantify balance using anterior/posterior (AP), medial/lateral (ML), and overall balance indices. Paired t-tests were used to compare the balance indices for the two conditions with alpha set at 0.05 a priori. Effect size was also calculated to account for the multiple comparisons made. The static balance indices did not display statistically significant differences between the post-cryotherapy and the control conditions with low effect sizes. Dynamic ML indices significantly increased following the cryotherapy application compared to the control exhibiting a moderate effect size indicating decreased balance following cryotherapy application. No differences were noted between experimental and control conditions for the dynamic AP or overall balance indices while a small effect size was noted for both. The results suggest that cryotherapy to the ankle has a negative effect on the ML component of dynamic balance following ice water immersion. Immediate return to play following cryotherapy application is cautioned given the decreased dynamic ML balance and potential for increased injury risk. 3b Case-control study.

  19. A preliminary study of static and dynamic balance in sedentary obese young adults: the relationship between BMI, posture and postural balance.

    Science.gov (United States)

    do Nascimento, J A; Silva, C C; Dos Santos, H H; de Almeida Ferreira, J J; de Andrade, P R

    2017-12-01

    The aim of this study was to evaluate the postural control of obese young adults with normal body mass index during different static (bipedic and unipedic support) and dynamic postural conditions (gait velocity and limits of stability) in order to compare the static and dynamic balance of these individuals. A cross-sectional quantitative study was carried out to evaluate static and dynamic balance in 25 sedentary individuals. The sample was divided into two groups, 10 in the normal-weight group (24.70 ± 3.89 years and 21.5 ± 1.66 kg m -2 ) and 15 in the obese group (26.80 ± 5.16 years and 35.66 ± 4.29 kg m -2 ). Postural evaluation was performed through visual inspection, and balance analyses were performed using the Timed Up & Go test (TUGT) and Balance System (Biodex). Descriptive analyses, Fisher's exact test and Mann Whitney U-tests were performed using the Statistical Package for Social Sciences (SPSS - 20.0, Armonk, NY) software. Most of the obese volunteers presented postural alterations, such as head protrusion (47.6%), hyperkyphosis (46.7%) and hyperlordosis (26.7%). Medial-lateral dynamic displacement, risk of falls and mean time to perform the limits of stability test and TUGT were higher for obese subjects (P  0.05) for static balance tests for either bipedal or unipedal tasks. The disadvantage presented by the young obese subjects occurs in dynamic activities, representing worse balance and an increase in time needed to accomplish these activities. © 2017 World Obesity Federation.

  20. Design and static structural analysis of a race car chassis for Formula Society of Automotive Engineers (FSAE) event

    Science.gov (United States)

    Mohamad, M. L.; Rahman, M. T. A.; Khan, S. F.; Basha, M. H.; Adom, A. H.; Hashim, M. S. M.

    2017-10-01

    The main purpose of this study is to make improvement for the UniMAP Automotive Racing Team car chassis which has several problems associated with the chassis must be fixed and some changes are needed to be made in order to perform well. This study involves the process of designing three chassis that are created based on the rules stated by FSAE rules book (2017/2018). The three chassis will undergo analysis test that consists of five tests which are main roll hoop test, front roll hoop test, static shear, side impact, static torsional loading and finally one of them will be selected as the best design in term of Von Mises Stress and torsional displacement. From the results obtained, the new selected chassis design which also declared as the new improved design poses the weight of 27.66 kg which was decreased by 16.7% from the existing chassis (32.77 kg). The torsional rigidity of the improved chassis increased by 37.74%.

  1. The Effect of Small Additions of Carbon Nanotubes on the Mechanical Properties of Epoxy Polymers under Static and Dynamic Loads

    Science.gov (United States)

    Tarasov, A. E.; Badamshina, E. R.; Anokhin, D. V.; Razorenov, S. V.; Vakorina, G. S.

    2018-01-01

    The results of measurements of the mechanical characteristics of cured epoxy composites containing small and ultrasmall additions of single-walled carbon nanotubes in the concentration range from 0 to 0.133 wt % under static and dynamic loads are presented. Static measurements of strength characteristics have been carried out under standard test conditions. Measurements of the Hugoniot elastic limit and spall strength were performed under a shock wave loading of the samples at a deformation rate of (0.8-1.5) ß 105 s-1 before the fracture using explosive devices by recording and subsequent analyzing the evolution of the full wave profiles. It has been shown that agglomerates of nanotubes present in the structure of the composites after curing cause a significant scatter of the measured strength parameters, both in the static and in the dynamic test modes. However, the effects of carbon nanotube additions in the studied concentration interval on the physical and mechanical characteristics of the parameters were not revealed for both types of loading.

  2. Evaluation of Induced Settlements of Piled Rafts in the Coupled Static-Dynamic Loads Using Neural Networks and Evolutionary Polynomial Regression

    Directory of Open Access Journals (Sweden)

    Ali Ghorbani

    2017-01-01

    Full Text Available Coupled Piled Raft Foundations (CPRFs are broadly applied to share heavy loads of superstructures between piles and rafts and reduce total and differential settlements. Settlements induced by static/coupled static-dynamic loads are one of the main concerns of engineers in designing CPRFs. Evaluation of induced settlements of CPRFs has been commonly carried out using three-dimensional finite element/finite difference modeling or through expensive real-scale/prototype model tests. Since the analyses, especially in the case of coupled static-dynamic loads, are not simply conducted, this paper presents two practical methods to gain the values of settlement. First, different nonlinear finite difference models under different static and coupled static-dynamic loads are developed to calculate exerted settlements. Analyses are performed with respect to different axial loads and pile’s configurations, numbers, lengths, diameters, and spacing for both loading cases. Based on the results of well-validated three-dimensional finite difference modeling, artificial neural networks and evolutionary polynomial regressions are then applied and introduced as capable methods to accurately present both static and coupled static-dynamic settlements. Also, using a sensitivity analysis based on Cosine Amplitude Method, axial load is introduced as the most influential parameter, while the ratio l/d is reported as the least effective parameter on the settlements of CPRFs.

  3. Statics formulas and problems : engineering mechanics 1

    CERN Document Server

    Gross, Dietmar; Wriggers, Peter; Schröder, Jörg; Müller, Ralf

    2017-01-01

    This book contains the most important formulas and more than 160 completely solved problems from Statics. It provides engineering students material to improve their skills and helps to gain experience in solving engineering problems. Particular emphasis is placed on finding the solution path and formulating the basic equations. Topics include: - Equilibrium - Center of Gravity, Center of Mass, Centroids - Support Reactions - Trusses - Beams, Frames, Arches - Cables - Work and Potential Energy - Static and Kinetic Friction - Moments of Inertia.

  4. Statics and rotational dynamics of composite beams

    CERN Document Server

    Ghorashi, Mehrdaad

    2016-01-01

    This book presents a comprehensive study of the nonlinear statics and dynamics of composite beams and consists of solutions with and without active elements embedded in the beams. The static solution provides the initial conditions for the dynamic analysis. The dynamic problems considered include the analyses of clamped (hingeless) and articulated (hinged) accelerating rotating beams. Two independent numerical solutions for the steady state and the transient responses are presented. The author illustrates that the transient solution of the nonlinear formulation of accelerating rotating beam converges to the steady state solution obtained by the shooting method. Other key areas considered include calculation of the effect of perturbing the steady state solution, coupled nonlinear flap-lag dynamics of a rotating articulated beam with hinge offset and aerodynamic damping, and static and dynamic responses of nonlinear composite beams with embedded anisotropic piezo-composite actuators. The book is intended as a t...

  5. EXAMINATION OF EFFECTS OF DEVELOPMENT GYMNASTICS TEACHING OF PHYSICAL EDUCATION ON STATIC STRENGTH OF 3TH & 4TH GRADE PUPILS OF ELEMENTARY SCHOOLS

    Directory of Open Access Journals (Sweden)

    Dragana Aleksić

    2011-09-01

    Full Text Available In this work, the subject of the research is only one segment of the anthropological area, which refers to the appearance of appropriate motor abilities-coordination. Static strength Static strength is ability to retain in nonmetrics contraction of muscle that body is preserved in certain position. Static work as physical work doesn’t exist in static strength, because development doesn’t exist, but quality of static work the muscle should start with physiology’s opinion of work. Static work is used for demonstration the power during that last.The battery for the evaluation of static strength consists of the following tests: MVIS, MIPR, MINS. During the 2005/06 academic year, a research was conducted so as to determine the effects of current program of physical education teaching on motor abilities coordination of female pupils. The research involved a total sample of 102 girls from the 3th and 4th grade of elementary school. The subjects were classified in one experimental and one control group. The experimental group was made of 54 studentsand they were practicing according to planning instruction where the artistic gymnastics had the primary part. The control group of 48 students was practicing according to official instructional plan and program for P.E. of the Republic of Serbia. At the beginning of the academic year, initial (first measurement was performed, followed by experimental final (second measurement at the end of experiment. The multi-variant procedures were used in this research ant those were: the multi-variant analysis of the variable (MANCOVA, MANOVA. Also, the mono-variant procedures were used and those were: the variable analysis (ANCOVA, ANOVA and the interval of entrust. After the experimental treatment, i.e. at the final testing, significant differences were found with female pupils in the experimental and control groups concerning the one of three tests for the evaluation of static strength. The basic conclusion is

  6. The effect of 8 weeks of whole body vibration training on static balance and explosive strength of lower limbs in physical education students

    Directory of Open Access Journals (Sweden)

    George Dallas

    2017-12-01

    Full Text Available Background: It has been shown that whole body vibration training has an effect on strength and balance in athletes of various sports.Objective: The purpose of the study was to examine the effect of 8 weeks of Whole Body Vibration (WBV training on static balance and explosive strength of the lower limbs, using two different training intensities vibration protocols.Methods: Eighty-three physical education students (age 19.39 ± 2.35 years volunteered to participate in an 8-week WBV training. They were randomly divided into two groups with 30 sec and 60 sec duration of vibration exposure per exercise, total volume of exercise was the same for both groups. The explosive strength of the lower limbs was assessed by a squat jump and static balance by Balance Error Scoring System at the baseline (pre-test and after 8 weeks of WBV training at 15 sec, 5, 10, and 15 min after the end of WBV exposure. A two-way ANOVA 2 × 5 (protocol × time with repeated measures on both factors was used. Univariate analyses with simple contrasts across time were selected as post hoc tests.Results: Results showed a time × protocol interaction effect for static balance (p < .001 but not for the squat jump (p > .05. Furthermore, a time effect was found for the static balance and squat jump test. The 60 sec protocol had a greater percentage improvement compared to the 30 sec protocol in static balance (p = .003, whereas the 30 sec protocol was superior to the 60 sec protocol in explosive strength. However, the differences between the two protocols were not significant.Conclusion: WBV training had positive effects on static balance and explosive strength in physical education students. Balance and jump performance may benefit from WBV training. Therefore, WBV may be an effective training method for the improvement of static balance and lower limb strength.

  7. Computerized adaptive testing--ready for ambulatory monitoring?

    DEFF Research Database (Denmark)

    Rose, Matthias; Bjørner, Jakob; Fischer, Felix

    2012-01-01

    Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted.......Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted....

  8. Static mechanical properties of 30 x 11.5-14.5, type VII, aircraft tires of bias-ply and radial-belted design

    Science.gov (United States)

    Davis, Pamela A.; Lopez, Mercedes C.

    1987-01-01

    An investigation was conducted to determine the static mechanical characteristics of 30 x 115-14.5 bias-ply and radial aircraft tires. The tires were subjected to vertical and lateral loads and mass moment of inertia tests were conducted. Static load deflection curves, spring rates, hysteresis losses, and inertia data are presented along with a discussion of the advantages and disadvantages of one tire over the other.

  9. Development of a clinical static and dynamic standing balance measurement tool appropriate for use in adolescents.

    Science.gov (United States)

    Emery, Carolyn A; Cassidy, J David; Klassen, Terry P; Rosychuk, Rhonda J; Rowe, Brian B

    2005-06-01

    There is a need in sports medicine for a static and dynamic standing balance measure to quantify balance ability in adolescents. The purposes of this study were to determine the test-retest reliability of timed static (eyes open) and dynamic (eyes open and eyes closed) unipedal balance measurements and to examine factors associated with balance. Adolescents (n=123) were randomly selected from 10 Calgary high schools. This study used a repeated-measures design. One rater measured unipedal standing balance, including timed eyes-closed static (ECS), eyes-open dynamic (EOD), and eyes-closed dynamic (ECD) balance at baseline and 1 week later. Dynamic balance was measured on a foam surface. Reliability was examined using both intraclass correlation coefficients (ICCs) and Bland and Altman statistical techniques. Multiple linear regressions were used to examine other potentially influencing factors. Based on ICCs, test-retest reliability was adequate for ECS, EOD, and ECD balance (ICC=.69, .59, and .46, respectively). The results of Bland and Altman methods, however, suggest that caution is required in interpreting reliability based on ICCs alone. Although both ECS balance and ECD balance appear to demonstrate adequate test-retest reliability by ICC, Bland and Altman methods of agreement demonstrate sufficient reliability for ECD balance only. Thirty percent of the subjects reached the 180-second maximum on EOD balance, suggesting that this test is not appropriate for use in this population. Balance ability (ECS and ECD) was better in adolescents with no past history of lower-extremity injury. Timed ECD balance is an appropriate and reliable clinical measurement for use in adolescents and is influenced by previous injury.

  10. Static Behaviour of Natural Gas and its Flow in Pipes

    OpenAIRE

    Ohirhian, Peter

    2010-01-01

    1. 2. A general differential equation that governs static behavior of any fluid and its flow in horizontal, uphill and downhill pipes has been developed. classical fourth order Runge-Kutta numerical method is programmed in Fortran 77, to test the equation and results are accurate. The program shows that a length ncrement as large as 10,000 ft can be used in the Runge-Kutta method of solution to differential equation during uphill gas flow and up to 5700ft for downhill gas flow The Runge-Kutta...

  11. Nuclear static eliminators halt airborne contamination and enhance personnel safety

    International Nuclear Information System (INIS)

    Edelmann, G.F.; Regan, J.T.

    1985-01-01

    In January 1984, Nelco Products, Inc. opened a new plant in Fullerton, CA to produce fiberglass/epoxy sheet stock which is used to manufacture single-sided, double-sided and multi-layer printed circuit boards (PCB) for electronic and telecommunications apparatus. The process for making the PCB core material begins with woven fiberglass fabric which passes through a series of metal take-up and tensioning rollers, and is then immersed in and impregnated with an equivalent weight of epoxy resin. Shortly after startup, the plant encountered quality control and safety problems due to electrostatic charges that commonly occur when processing non-conductors such as fiberglass plastics and paper given serious consideration until the plant had been operating for about six months and continued to have quality and safety problems due to static charges. The engineers decided to try a bar-type nuclear static eliminator containing polonium 210 (Po-210) whose emissions create both negative and positive air ions. The nuclear-powered device is available only on an annual renewable lease, because the normal useful life is one year, and the US Nuclear Regulatory Commission requires a leak test each 12 months. A fresh bar is shipped to the lessee at the end of the 12-month period, and the old one is returned to the lessor. The nuclear-powered static eliminators have improved the quality of the PCB core material since the fiberglass cloth is practically free of any dirt or dust before it enters the resin-impregnating bath. Furthermore, the operators no longer complain about electrical shocks

  12. SU-F-T-645: To Test Spatial Anddosimetric Accuracy of Small Cranial Target Irradiation Based On 1.5 T MRIscans Using Static Arcs with MLCDefined Fields

    International Nuclear Information System (INIS)

    Brezovich, I; Wu, X; Popple, R; Shen, S; Cardan, R; Bolding, M; Fiveash, J; Kraus, J; Spencer, S

    2016-01-01

    Purpose: To test spatial and dosimetric accuracy of small cranial target irradiation based on 1.5 T MRI scans using static arcs with MLC-defined fields Methods: A plastic (PMMA) phantom simulating a small brain lesion was mounted on a GammaKnife headframe equipped with MRI localizer. The lesion was a 3 mm long, 3.175 mm diameter cylindrical cavity filled with MRI contrast. Radiochromic film passing through the cavity was marked with pin pricks at the cavity center. The cavity was contoured on an MRI image and fused with CT to simulate treatment of a lesion not visible on CT. The transfer of the target to CT involved registering the MRI contrast cannels of the localizer that were visible on both modalities. Treatments were planned to deliver 800 cGy to the cavity center using multiple static arcs with 5.0×2.4 mm MLC-defined fields. The phantom was aligned on a STx accelerator by registering the conebeam CT with the planning CT. Films from coronal and sagittal planes were scanned and evaluated using ImageJ software Results: Geographic errors in treatment based on 1.5 T scans agreed within 0.33, −0.27 and 1.21 mm in the vertical, lateral and longitudinal dimensions, respectively. The doses delivered to the cavity center were 7.2% higher than planned. The dose distributions were similar to those of a GammaKnife. Conclusion: Radiation can be delivered with an accelerator at mm accuracy to small cranial targets based on 1.5 MRI scans fused to CTs using a standard GammaKnife headframe and MRI localizer. MLC-defined static arcs produce isodose lines very similar to the GammaKnife.

  13. Navigating on handheld displays: Dynamic versus Static Keyhole Navigation

    NARCIS (Netherlands)

    Mehra, S.; Werkhoven, P.; Worring, M.

    2006-01-01

    Handheld displays leave little space for the visualization and navigation of spatial layouts representing rich information spaces. The most common navigation method for handheld displays is static peephole navigation: The peephole is static and we move the spatial layout behind it (scrolling). A

  14. A Transformational Approach to Parametric Accumulated-Cost Static Profiling

    DEFF Research Database (Denmark)

    Haemmerlé, Rémy; López García, Pedro; Liqat, Umer

    2016-01-01

    Traditional static resource analyses estimate the total resource usage of a program, without executing it. In this paper we present a novel resource analysis whose aim is instead the static profiling of accumulated cost, i.e., to discover, for selected parts of the program, an estimate or bound...... of the resource usage accumulated in each of those parts. Traditional resource analyses are parametric in the sense that the results can be functions on input data sizes. Our static profiling is also parametric, i.e., our accumulated cost estimates are also parameterized by input data sizes. Our proposal is based...... on the concept of cost centers and a program transformation that allows the static inference of functions that return bounds on these accumulated costs depending on input data sizes, for each cost center of interest. Such information is much more useful to the software developer than the traditional resource...

  15. Static Deadlock Detection in MPI Synchronization Communication

    OpenAIRE

    Ming-Xue, Liao; Xiao-Xin, He; Zhi-Hua, Fan

    2007-01-01

    It is very common to use dynamic methods to detect deadlocks in MPI programs for the reason that static methods have some restrictions. To guarantee high reliability of some important MPI-based application software, a model of MPI synchronization communication is abstracted and a type of static method is devised to examine deadlocks in such modes. The model has three forms with different complexity: sequential model, single-loop model and nested-loop model. Sequential model is a base for all ...

  16. Performance of static var compensator control type thyristor controlled reactor and thyristor switched capacitor

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Josias M. de; Yung, Chou Shaw; Rose, Eber H; Pantoja, Antonio L.A. [ELETRONORTE, Belem, PA (Brazil); Fouesnant, Thomas; Boissier, Luc

    1994-12-31

    This paper has the objective of presenting the philosophy of Static Var Compensator (SVC) Control as well the necessary adjustments in the project of control system to guarantee suitable performance under different operating conditions. The verification on the performance of the SVC control has been done by Transient Network Analyzer (TNA/CEPEL) studies, commissioning tests and a factory tests. The SVC is the type of Thyristor Controlled Reactor (TCR) and Thyristor Switched Capacitor (TSC). (author) 3 refs., 12 figs.

  17. Static and wind tunnel near-field/far-field jet noise measurements from model scale single-flow base line and suppressor nozzles. Summary report. [conducted in the Boeing large anechoic test chamber and the NASA-Ames 40by 80-foot wind tunnel

    Science.gov (United States)

    Jaeck, C. L.

    1977-01-01

    A test program was conducted in the Boeing large anechoic test chamber and the NASA-Ames 40- by 80-foot wind tunnel to study the near- and far-field jet noise characteristics of six baseline and suppressor nozzles. Static and wind-on noise source locations were determined. A technique for extrapolating near field jet noise measurements into the far field was established. It was determined if flight effects measured in the near field are the same as those in the far field. The flight effects on the jet noise levels of the baseline and suppressor nozzles were determined. Test models included a 15.24-cm round convergent nozzle, an annular nozzle with and without ejector, a 20-lobe nozzle with and without ejector, and a 57-tube nozzle with lined ejector. The static free-field test in the anechoic chamber covered nozzle pressure ratios from 1.44 to 2.25 and jet velocities from 412 to 594 m/s at a total temperature of 844 K. The wind tunnel flight effects test repeated these nozzle test conditions with ambient velocities of 0 to 92 m/s.

  18. Model tests on dynamic performance of RC shear walls

    International Nuclear Information System (INIS)

    Nagashima, Toshio; Shibata, Akenori; Inoue, Norio; Muroi, Kazuo.

    1991-01-01

    For the inelastic dynamic response analysis of a reactor building subjected to earthquakes, it is essentially important to properly evaluate its restoring force characteristics under dynamic loading condition and its damping performance. Reinforced concrete shear walls are the main structural members of a reactor building, and dominate its seismic behavior. In order to obtain the basic information on the dynamic restoring force characteristics and damping performance of shear walls, the dynamic test using a large shaking table, static displacement control test and the pseudo-dynamic test on the models of a shear wall were conducted. In the dynamic test, four specimens were tested on a large shaking table. In the static test, four specimens were tested, and in the pseudo-dynamic test, three specimens were tested. These tests are outlined. The results of these tests were compared, placing emphasis on the restoring force characteristics and damping performance of the RC wall models. The strength was higher in the dynamic test models than in the static test models mainly due to the effect of loading rate. (K.I.)

  19. Foot deformation during walking: differences between static and dynamic 3D foot morphology in developing feet.

    Science.gov (United States)

    Barisch-Fritz, Bettina; Schmeltzpfenning, Timo; Plank, Clemens; Grau, Stefan

    2014-01-01

    The complex functions of feet require a specific composition, which is progressively achieved by developmental processes. This development should take place without being affected by footwear. The aim of this study is to evaluate differences between static and dynamic foot morphology in developing feet. Feet of 2554 participants (6-16 years) were recorded using a new scanner system (DynaScan4D). Each foot was recorded in static half and full weight-bearing and during walking. Several foot measures corresponding to those used in last construction were calculated. The differences were identified by one-way ANOVA and paired Student's t-test. Static and dynamic values of each foot measure must be considered to improve the fit of footwear. In particular, footwear must account for the increase of forefoot width and the decrease of midfoot girth. Furthermore, the toe box should have a more rounded shape. The findings are important for the construction of footwear for developing feet.

  20. 14 CFR 27.610 - Lightning and static electricity protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Lightning and static electricity protection....610 Lightning and static electricity protection. (a) The rotorcraft must be protected against catastrophic effects from lightning. (b) For metallic components, compliance with paragraph (a) of this section...

  1. Static friction of stainless steel wire rope–rubber contacts.

    NARCIS (Netherlands)

    Loeve, A.J.; Krijger, T.; Mugge, W.; Breedveld, P.; Dodou, D.; Dankelman, J.

    2014-01-01

    Little is known about static friction of stainless-steel wire ropes ('cables') in contact with soft rubbers, an interface of potential importance for rigidifiable medical instruments. Although friction theories imply that the size and profile of the cables affect static friction, there are no

  2. A simple criterion for determining the static friction force between nanowires and flat substrates using the most-bent-state method.

    Science.gov (United States)

    Hou, Lizhen; Wang, Shiliang; Huang, Han

    2015-04-24

    A simple criterion was developed to assess the appropriateness of the currently available models that estimate the static friction force between nanowires and substrates using the 'most-bent-state' method. Our experimental testing of the static friction force between Al2O3 nanowires and Si substrate verified our theoretical analysis, as well as the establishment of the criterion. It was found that the models are valid only for the bent nanowires with the ratio of wire length over the minimum curvature radius [Formula: see text] no greater than 1. For the cases with [Formula: see text] greater than 1, the static friction force was overestimated as it neglected the effect of its tangential component.

  3. Relationship between Static Stiffness and Modal Stiffness of Structures

    Directory of Open Access Journals (Sweden)

    Tianjian Ji Tianjian Ji

    2010-02-01

    Full Text Available This paper derives the relationship between the static stiffness and modal stiffness of a structure. The static stiffness and modal stiffness are two important concepts in both structural statics and dynamics. Although both stiffnesses indicate the capacity of the structure to resist deformation, they are obtained using different methods. The former is calculated by solving the equations of equilibrium and the latter can be obtained by solving an eigenvalue problem. A mathematical relationship between the two stiffnesses was derived based on the definitions of two stiffnesses. This relationship was applicable to a linear system and the derivation of relationships does not reveal any other limitations. Verification of the relationship was given by using several examples. The relationship between the two stiffnesses demonstrated that the modal stiffness of the fundamental mode was always larger than the static stiffness of a structure if the critical point and the maximum mode value are at the same node, i.e. for simply supported beam and seven storeys building are 1.5% and 15% respectively. The relationship could be applied into real structures, where the greater the number of modes being considered, the smaller the difference between the modal stiffness and the static stiffness of a structure.

  4. Power system static state estimation using Kalman filter algorithm

    Directory of Open Access Journals (Sweden)

    Saikia Anupam

    2016-01-01

    Full Text Available State estimation of power system is an important tool for operation, analysis and forecasting of electric power system. In this paper, a Kalman filter algorithm is presented for static estimation of power system state variables. IEEE 14 bus system is employed to check the accuracy of this method. Newton Raphson load flow study is first carried out on our test system and a set of data from the output of load flow program is taken as measurement input. Measurement inputs are simulated by adding Gaussian noise of zero mean. The results of Kalman estimation are compared with traditional Weight Least Square (WLS method and it is observed that Kalman filter algorithm is numerically more efficient than traditional WLS method. Estimation accuracy is also tested for presence of parametric error in the system. In addition, numerical stability of Kalman filter algorithm is tested by considering inclusion of zero mean errors in the initial estimates.

  5. Quasi-static structural optimization under the seismic loads

    International Nuclear Information System (INIS)

    Choi, W. S.; Lee, K. M.; Kim, T. W.

    2001-01-01

    For preliminaries to optimization of SMART under the seismic loads, a quasi-static structural optimization for elastic structures under dynamic loads is presented. An equivalent static load (ESL) set is defined as a static load set, which generates the same displacement field as that from a dynamic load at a certain time. Multiple ESL sets calculated at all the time intervals are employed to represent the various states of the structure under the dynamic load. They can cover all the critical states that might happen at arbitrary times. The continuous characteristics of a dynamic load are considered by multiple static load sets. The calculated sets of ESLs are utilized as a multiple loading condition in the optimization process. A design cycle is defined as a circulated process between an analysis domain and a design domain. The analysis domain gives the loading condition needed in the design domain. The design domain gives a new updated design to be verified by the analysis domain in the next design cycle. The design cycles are iterated until the design converges. Structural optimization with dynamic loads is tangible by the proposed method. Standard example problems are solved to verify the validity of the method

  6. Relationship between static foot posture and foot mobility

    Directory of Open Access Journals (Sweden)

    McPoil Thomas G

    2011-01-01

    Full Text Available Abstract Background It is not uncommon for a person's foot posture and/or mobility to be assessed during a clinical examination. The exact relationship, however, between static posture and mobility is not known. Objective The purpose of this study was to determine the degree of association between static foot posture and mobility. Method The static foot posture and foot mobility of 203 healthy individuals was assessed and then analyzed to determine if low arched or "pronated" feet are more mobile than high arched or "supinated" feet. Results The study demonstrated that those individuals with a lower standing dorsal arch height and/or a wider standing midfoot width had greater mobility in their foot. In addition, those individuals with higher Foot Posture Index (FPI values demonstrated greater mobility and those with lower FPI values demonstrated less mobility. Finally, the amount of foot mobility that an individual has can be predicted reasonably well using either a 3 or 4 variable linear regression model. Conclusions Because of the relationship between static foot posture and mobility, it is recommended that both be assessed as part of a comprehensive evaluation of a individual with foot problems.

  7. Developmental model of static allometry in holometabolous insects.

    Science.gov (United States)

    Shingleton, Alexander W; Mirth, Christen K; Bates, Peter W

    2008-08-22

    The regulation of static allometry is a fundamental developmental process, yet little is understood of the mechanisms that ensure organs scale correctly across a range of body sizes. Recent studies have revealed the physiological and genetic mechanisms that control nutritional variation in the final body and organ size in holometabolous insects. The implications these mechanisms have for the regulation of static allometry is, however, unknown. Here, we formulate a mathematical description of the nutritional control of body and organ size in Drosophila melanogaster and use it to explore how the developmental regulators of size influence static allometry. The model suggests that the slope of nutritional static allometries, the 'allometric coefficient', is controlled by the relative sensitivity of an organ's growth rate to changes in nutrition, and the relative duration of development when nutrition affects an organ's final size. The model also predicts that, in order to maintain correct scaling, sensitivity to changes in nutrition varies among organs, and within organs through time. We present experimental data that support these predictions. By revealing how specific physiological and genetic regulators of size influence allometry, the model serves to identify developmental processes upon which evolution may act to alter scaling relationships.

  8. Girls with generalized joint hypermobility display changed muscle activity and postural sway during static balance tasks

    DEFF Research Database (Denmark)

    Juul-Kristensen, B; Johansen, Kl; Hendriksen, P

    2016-01-01

    OBJECTIVES: To study knee muscle activity and static postural sway in girls with generalized joint hypermobility (GJH). METHOD: Sixteen girls with GJH and 11 girls with non-GJH (NGJH) aged 14 years, randomly recruited among schoolchildren, participated in this study. GJH inclusion criteria were......: Beighton score minimum 6/9 and one hypermobile knee; for NGJH: Beighton score maximum 5/9 and no knees with hypermobility. The participants performed a static two-legged balance test with eyes open (2EO) and eyes closed (2EC) and a one-legged stance test with eyes open (1EO). Postural sway (centre......) of Q, H, and G muscle activity was calculated. Knee function was self-reported using the Knee Injury and Osteoarthritis Outcome Score for children (KOOS-Child). RESULTS: GJH had a significantly lower lateral HQ CCI and a higher medial/lateral HQ CCI ratio in all balance tasks. Group mean EMG varied...

  9. Fast and Safe Concrete Code Execution for Reinforcing Static Analysis and Verification

    Directory of Open Access Journals (Sweden)

    M. Belyaev

    2015-01-01

    Full Text Available The problem of improving precision of static analysis and verification techniques for C is hard due to simplification assumptions these techniques make about the code model. We present a novel approach to improving precision by executing the code model in a controlled environment that captures program errors and contract violations in a memory and time efficient way. We implemented this approach as an executor module Tassadar as a part of bounded model checker Borealis. We tested Tassadar on two test sets, showing that its impact on performance of Borealis is minimal.The article is published in the authors’ wording.

  10. Static and kinetic friction force and surface roughness of different archwire-bracket sliding contacts.

    Science.gov (United States)

    Carrion-Vilches, Francisco J; Bermudez, María-Dolores; Fructuoso, Paula

    2015-01-01

    The aim of this study was to determine the static and kinetic friction forces of the contact bracket-archwire with different dental material compositions in order to select those materials with lower resistance to sliding. We carried out sliding friction tests by means of a universal testing machine following an experimental procedure as described in ASTM D1894 standard. We determined the static and kinetic friction forces under dry and lubricating conditions using an artificial saliva solution at 36.5ºC. The bracket-archwire pairs studied were: stainless steel-stainless steel; stainless steel-glass fiber composite; stainless steel-Nitinol 60; sapphire-stainless steel; sapphire-glass fiber composite; and sapphire-Nitinol 60. The best performance is obtained for Nitinol 60 archwire sliding against a stainless steel bracket, both under dry and lubricated conditions. These results are in agreement with the low surface roughness of Nitinol 60 with respect to the glass fiber composite archwire. The results described here contribute to establishing selection criteria for materials for dental archwire-brackets.

  11. 14 CFR 29.610 - Lightning and static electricity protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Lightning and static electricity protection... § 29.610 Lightning and static electricity protection. (a) The rotorcraft structure must be protected against catastrophic effects from lightning. (b) For metallic components, compliance with paragraph (a) of...

  12. Static multiplicities in heterogeneous azeotropic distillation sequences

    DEFF Research Database (Denmark)

    Esbjerg, Klavs; Andersen, Torben Ravn; Jørgensen, Sten Bay

    1998-01-01

    In this paper the results of a bifurcation analysis on heterogeneous azeotropic distillation sequences are given. Two sequences suitable for ethanol dehydration are compared: The 'direct' and the 'indirect' sequence. It is shown, that the two sequences, despite their similarities, exhibit very...... different static behavior. The method of Petlyuk and Avet'yan (1971), Bekiaris et al. (1993), which assumes infinite reflux and infinite number of stages, is extended to and applied on heterogeneous azeotropic distillation sequences. The predictions are substantiated through simulations. The static sequence...

  13. Assessment of the hazard to the public from anti-static brushes containing polonium-210 in the form of ceramic microspheres

    International Nuclear Information System (INIS)

    Webb, G.A.M.; Wilkins, B.T.; Wrixon, A.D.

    1975-04-01

    Anti-static brushes containing polonium-210 in the form of ceramic microspheres have been tested and evaluated with regard to their availability to the general public. After summarising existing test information, results are given of routine leakage tests and special tests intended to simulate severe but credible abuse and accidents with these devices. It is found that the low levels of removable contamination and the possible loss of complete microspheres, although in principle undesirable, do not present a significant hazard. The containment integrity of ceramic microspheres under severe conditions (impact and fire) has been found unsatisfactory and it is considered possible that ICRP dose limits could be approached or even exceeded under these severe but credible abuse, accident or disposal conditions. The results of comparative tests with nonradioactive methods for static elimination did not demonstrate any adequate justification for the use of a radioactive material. The potential exposure from Staticmaster Brushes is therefore considered an unnecessary hazard to members of the public. (author)

  14. Interaction mechanisms and biological effects of static magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Tenforde, T.S.

    1994-06-01

    Mechanisms through which static magnetic fields interact with living systems are described and illustrated by selected experimental observations. These mechanisms include electrodynamic interactions with moving, ionic charges (blood flow and nerve impulse conduction), magnetomechanical interactions (orientation and translation of molecules structures and magnetic particles), and interactions with electronic spin states in charge transfer reactions (photo-induced electron transfer in photosynthesis). A general summary is also presented of the biological effects of static magnetic fields. There is convincing experimental evidence for magnetoreception mechanisms in several classes of lower organisms, including bacteria and marine organisms. However, in more highly evolved species of animals, there is no evidence that the interactions of static magnetic fields with flux densities up to 2 Tesla (1 Tesla [T] = 10{sup 4} Gauss) produce either behavioral or physiolocical alterations. These results, based on controlled studies with laboratory animals, are consistent with the outcome of recent epidemiological surveys on human populations exposed occupationally to static magnetic fields.

  15. Static and kinematic formulation of planar reciprocal assemblies

    DEFF Research Database (Denmark)

    Parigi, Dario; Sassone, Mario; Kirkegaard, Poul Henning

    2014-01-01

    Planar reciprocal frames are two dimensional structures formed by elements joined together according to the principle of structural reciprocity. In this paper a rigorous formulation of the static and kinematic problem is proposed and developed extending the theory of pin-jointed assemblies....... This formulation is used to evaluate the static and kinematic determinacy of reciprocal assemblies from the properties of their equilibrium and kinematic matrices...

  16. Comparison between ground tests and flight data for two static 32 KB memories

    International Nuclear Information System (INIS)

    Cheynet, Ph.; Velazco, R.; Cheynet, Ph.; Ecoffet, R.; Duzellier, S.; David, J.P.; Loquet, J.G.

    1999-01-01

    The study concerns two 32 K-byte static memories, one from Hitachi (HM62256) and the other (HM65756) from Matra-MHS. The results correspond to around one year of measurement in high radiation orbit and a total of 268 upsets were detected. As a preliminary conclusion it can be stated that the MHS SRAM is probably at least 4 times more sensitive to SEU (single event upset) than the Hitachi SRAM. The Hitachi memory has exhibited what we call ''stuck-at'' bit errors. This kind of event is identified when the same address and data is found in error (fixed read data) for several consecutive read cycles. A confrontation of SEU rates derived from predictions to those measured in flight has shown that: - error rate is underestimated for HM62256 using standard prediction models, - error rate can be under or over-estimated for HM65756 but the dispersion on heavy-ion ground results does not allow us to conclude. (A.C.)

  17. The Effect of Rope Jumping Exercise on Postural Control, Static and Dynamic Balance in Male Students with Cavus Foot

    Directory of Open Access Journals (Sweden)

    Mahdi Ghaderiyan

    2016-06-01

    Full Text Available Background and Objectives: Plantar foot is a very active part in leap activities, such as rope jumping and with its small surface playes an important role in balance control. In this research, the effect of 12 week rope jumping exercise was investigated on postural control and static and dynamic balance in 10-13 years old male students with cavus foot. Methods: This quasi-experimental study was done on 450 male students aged 13-10 years in Jarghouyeh sofla. After the initial evaluation by pedescope (qualitative and then measurement by a foot scanner (quantitative and Staheli index, 30 students were selected as samples and were divided into two groups (experimental and control, each 15 cases. To measure the postural control, a foot scanner device was used and changes in plantar center of pressure was recorded for 20 seconds. Static balance was evaluated with stork test and dynamic balance by Y balance test. The subjects of the experimental group participated in a rope jumping training protocol three 45-minute sessions per week for 12 weeks. In this period of time, the subjects of the control group did not participate in any regular physical activity program in this time. Data were analyzed using dependent and independent t-tests. The significance level was considered p<0/05. Results: A 12-week rope jumping exercise improved postural control and static and dynamic balance in patients with cavus foot, which this change was significant (p<0.001. Conclusion: According to the results of this study, rope jumping can be a useful exercise to improve static and dynamic balance and postural control in individuals with cavus foot.

  18. Tritiated Dust Levitation by Beta Induced Static Charge

    International Nuclear Information System (INIS)

    Skinner, C.H.; Gentile, C.A.; Ciebiera, L.; Langish, S.

    2003-01-01

    Tritiated particles have been observed to spontaneously levitate under the influence of a static electric field. Tritium containing co-deposits were mechanically scraped from tiles that had been used in the Tokamak Fusion Test Reactor (TFTR) inner limiter during the deuterium-tritium campaign and were placed in a glass vial. On rubbing the plastic cap of the vial a remarkable ''fountain'' of particles was seen inside the vial. Particles from an unused tile or from a TFTR co-deposit formed during deuterium discharges did not exhibit this phenomenon. It appears that tritiated particles are more mobile than other particles and this should be considered in assessing tokamak accident scenarios and in occupational safety

  19. Static facial expression recognition with convolution neural networks

    Science.gov (United States)

    Zhang, Feng; Chen, Zhong; Ouyang, Chao; Zhang, Yifei

    2018-03-01

    Facial expression recognition is a currently active research topic in the fields of computer vision, pattern recognition and artificial intelligence. In this paper, we have developed a convolutional neural networks (CNN) for classifying human emotions from static facial expression into one of the seven facial emotion categories. We pre-train our CNN model on the combined FER2013 dataset formed by train, validation and test set and fine-tune on the extended Cohn-Kanade database. In order to reduce the overfitting of the models, we utilized different techniques including dropout and batch normalization in addition to data augmentation. According to the experimental result, our CNN model has excellent classification performance and robustness for facial expression recognition.

  20. Rigidity of generalized Bach-flat vacuum static spaces

    Science.gov (United States)

    Yun, Gabjin; Hwang, Seungsu

    2017-11-01

    In this paper, we study the structure of generalized Bach-flat vacuum static spaces. Generalized Bach-flat metrics are considered as extensions of both Einstein and Bach-flat metrics. First, we prove that a compact Riemannian n-manifold with n ≥ 4 which is a generalized Bach-flat vacuum static space is Einstein. A generalized Bach-flat vacuum static space with the potential function f having compact level sets is either Ricci-flat or a warped product with zero scalar curvature when n ≥ 5, and when n = 4, it is Einstein if f has its minimum. Secondly, we consider critical metrics for another quadratic curvature functional involving the Ricci tensor, and prove similar results. Lastly, by applying the technique developed above, we prove Besse conjecture when the manifold is generalized Bach-flat.

  1. A quasi-static polynomial nodal method for nuclear reactor analysis

    International Nuclear Information System (INIS)

    Gehin, J.C.

    1992-09-01

    Modern nodal methods are currently available which can accurately and efficiently solve the static and transient neutron diffusion equations. Most of the methods, however, are limited to two energy groups for practical application. The objective of this research is the development of a static and transient, multidimensional nodal method which allows more than two energy groups and uses a non-linear iterative method for efficient solution of the nodal equations. For both the static and transient methods, finite-difference equations which are corrected by the use of discontinuity factors are derived. The discontinuity factors are computed from a polynomial nodal method using a non-linear iteration technique. The polynomial nodal method is based upon a quartic approximation and utilizes a quadratic transverse-leakage approximation. The solution of the time-dependent equations is performed by the use of a quasi-static method in which the node-averaged fluxes are factored into shape and amplitude functions. The application of the quasi-static polynomial method to several benchmark problems demonstrates that the accuracy is consistent with that of other nodal methods. The use of the quasi-static method is shown to substantially reduce the computation time over the traditional fully-implicit time-integration method. Problems involving thermal-hydraulic feedback are accurately, and efficiently, solved by performing several reactivity/thermal-hydraulic updates per shape calculation

  2. A quasi-static polynomial nodal method for nuclear reactor analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gehin, Jess C. [Massachusetts Inst. of Tech., Cambridge, MA (United States)

    1992-09-01

    Modern nodal methods are currently available which can accurately and efficiently solve the static and transient neutron diffusion equations. Most of the methods, however, are limited to two energy groups for practical application. The objective of this research is the development of a static and transient, multidimensional nodal method which allows more than two energy groups and uses a non-linear iterative method for efficient solution of the nodal equations. For both the static and transient methods, finite-difference equations which are corrected by the use of discontinuity factors are derived. The discontinuity factors are computed from a polynomial nodal method using a non-linear iteration technique. The polynomial nodal method is based upon a quartic approximation and utilizes a quadratic transverse-leakage approximation. The solution of the time-dependent equations is performed by the use of a quasi-static method in which the node-averaged fluxes are factored into shape and amplitude functions. The application of the quasi-static polynomial method to several benchmark problems demonstrates that the accuracy is consistent with that of other nodal methods. The use of the quasi-static method is shown to substantially reduce the computation time over the traditional fully-implicit time-integration method. Problems involving thermal-hydraulic feedback are accurately, and efficiently, solved by performing several reactivity/thermal-hydraulic updates per shape calculation.

  3. Screening of the field of a static charge in an anisotropic magnetized plasma

    International Nuclear Information System (INIS)

    Arsenin, V.V.; Puzitskii, M.L.

    1991-01-01

    The field of a static charge placed in an equilibrium plasma is screened at a distance of the order of the Debye radius. Debye screening occurs both with and without an external magnetic field. This property also persists when the plasma is not an equilibrium plasma but the velocity distribution function of the particles is isotropic (the screening radius in this case contains the characteristic value of the energy instead of the temperature). The situation can change if the distribution is anisotropic. First, the drop in the field can become non-Debye. In particular, in an unmagnetized plasma some distribution functions are characterized by a power-law decrease of the field. Second, a static test charge induces a magnetic as well as an electrostatic field in an anisotropic plasma. In this communication the authors describe the anomalies of screening of the field of a static charge in a magnetized plasma. For definiteness they consider a situation (typical, e.g., of magnetic mirror systems) when the ionic component is anisotropic. The simplifications for the sake of computations are limited to the case of a charge which extends along the magnetic field and only harmonics much longer than the Debye length are significant in the Fourier expansion of the density of this charge in the longitudinal coordinate

  4. Static stretching does not alter pre and post-landing muscle activation

    Directory of Open Access Journals (Sweden)

    Moss Wesley R

    2011-05-01

    Full Text Available Abstract Background Static stretching may result in various strength and power deficiencies. Prior research has not determined, however, if static stretching causes a change in muscle activation during a functional task requiring dynamic stability. The purpose of this study was to determine if static stretching has an effect on mean pre and postlanding muscle (vastus medialis VM, vastus lateralis VL, medial hamstring MH, and biceps femoris BF activity. Methods 26 healthy, physically active subjects were recruited, from which 13 completed a 14-day static stretching regimen for the quadriceps and hamstrings. Using the data from the force plate and EMG readings, a mean of EMG amplitude was calculated for 150 msec before and after landing. Each trial was normalized to an isometric reference position. Means were calculated for the VM, VL, MH, and BF from 5 trials in each session. Measures were collected pre, immediately following the 1st stretching session, and following 2 weeks of stretching. Results A 14-day static stretching regimen resulted in no significant differences in pre or postlanding mean EMG amplitude during a drop landing either acutely or over a 14-day period. Conclusions Static stretching, done acutely or over a 14-day period does not result in measurable differences of mean EMG amplitude during a drop landing. Static stretching may not impede dynamic stability of joints about which stretched muscles cross.

  5. The Norwegian Computerized Adaptive Test of Personality Disorder-Static Form (CAT-PD-SF): Reliability, Factor Structure, and Relationships With Personality Functioning.

    Science.gov (United States)

    Thimm, Jens C

    2017-12-01

    The Computerized Adaptive Test of Personality Disorder-Static Form (CAT-PD-SF) is a self-report inventory developed to assess pathological personality traits. The current study explored the reliability and higher order factor structure of the Norwegian version of the CAT-PD-SF and the relationships between the CAT-PD traits and domains of personality functioning in an undergraduate student sample ( N = 375). In addition to the CAT-PD-SF, the short form of the Severity Indices of Personality Problems and the Brief Symptom Inventory were administered. The results showed that the Norwegian CAT-PD-SF has good score reliability. Factor analysis of the CAT-PD-SF scales indicated five superordinate factors that correspond to the trait domains of the alternative DSM-5 model for personality disorders. The CAT-PD traits were highly predictive of impaired personality functioning after controlling for psychological distress. It is concluded that the CAT-PD-SF is a promising tool for the assessment of personality disorder traits.

  6. Contagion processes on the static and activity driven coupling networks

    OpenAIRE

    Lei, Yanjun; Jiang, Xin; Guo, Quantong; Ma, Yifang; Li, Meng; Zheng, Zhiming

    2015-01-01

    The evolution of network structure and the spreading of epidemic are common coexistent dynamical processes. In most cases, network structure is treated either static or time-varying, supposing the whole network is observed in a same time window. In this paper, we consider the epidemic spreading on a network consisting of both static and time-varying structures. At meanwhile, the time-varying part and the epidemic spreading are supposed to be of the same time scale. We introduce a static and a...

  7. Simulation of the Static VAR Compensator Culiacan Three Substation for the Analysis of Transients

    Directory of Open Access Journals (Sweden)

    Coronel-Mercado Luis Enrique

    2013-06-01

    Full Text Available Since its emergence in the late 60’s the FACTS (Flexible AC Transmission Systems have been and continue to be studied and implemented in all electrical networks around the world, becoming an essential element for stability, control and maximum exploitation of thereof. One of the most used FACTS devices is the Static VAR Compensator or SVC. In this work, the modeling in Simulink of the Static VAR Compensator installed at the substation Culiacán Tres (CUT belonging to CFE is presented. The SVC is the ability of ±100 MVAR and ABB brand. The modeling was performed to visually program in detail the different subsystems in Simulink such as the timing unit, the TSC (thyristor switched capacitor, TCR (thyristor controlled reactors, filters of the 5th and the 7th harmonic, the transformer bank, the control unit, distribution unit and the measurement unit. Data for major components were taken from data sheet and equipment manuals. ASPEN software was used in order to obtain Thevenin equivalent of the EPS to connect to them the SVC model to test the step and three-phase short circuit. The results of these tests were compared with test results of commissioning of the SVC.

  8. MEMS linear and nonlinear statics and dynamics

    CERN Document Server

    Younis, Mohammad I

    2011-01-01

    MEMS Linear and Nonlinear Statics and Dynamics presents the necessary analytical and computational tools for MEMS designers to model and simulate most known MEMS devices, structures, and phenomena. This book also provides an in-depth analysis and treatment of the most common static and dynamic phenomena in MEMS that are encountered by engineers. Coverage also includes nonlinear modeling approaches to modeling various MEMS phenomena of a nonlinear nature, such as those due to electrostatic forces, squeeze-film damping, and large deflection of structures. The book also: Includes examples of nume

  9. Stability of the Einstein static universe in open cosmological models

    International Nuclear Information System (INIS)

    Canonico, Rosangela; Parisi, Luca

    2010-01-01

    The stability properties of the Einstein static solution of general relativity are altered when corrective terms arising from modification of the underlying gravitational theory appear in the cosmological equations. In this paper the existence and stability of static solutions are considered in the framework of two recently proposed quantum gravity models. The previously known analysis of the Einstein static solutions in the semiclassical regime of loop quantum cosmology with modifications to the gravitational sector is extended to open cosmological models where a static neutrally stable solution is found. A similar analysis is also performed in the framework of Horava-Lifshitz gravity under detailed balance and projectability conditions. In the case of open cosmological models the two solutions found can be either unstable or neutrally stable according to the admitted values of the parameters.

  10. Glycerol and microwave preservation of annual statice (Limonium sinuatum Mill.)

    International Nuclear Information System (INIS)

    Paparozzi, E.T.; McCallister, D.E.

    1988-01-01

    Stems of annual statice (Limonium sinuatum Mill.) were harvested from the field in 1982 and soaked in varying concentrations of glycerol: water solutions for 24 and 48 h and then microwaved for 0, 1, 3 or 5 min. Half of the branch stems were measured for flexibility, with the remainder being assessed 1 year later. Stems harvested in 1983 were wet- and dry-stored at 3°C for varying lengths of time and then preserved. Preservation was best when statice was preserved immediately. Cold storage decreased preserved statice flexibility, but was better than air-drying. Fresh cut statice stems, up to 34 cm long, should be preserved by soaking in a 1:2 or 1:3 glycerol: water solution for 48 h followed by microwaving for 1 min at medium-high (34°C)

  11. Extending Graphic Statics for User-Controlled Structural Morphogenesis

    OpenAIRE

    Fivet, Corentin; Zastavni, Denis; Cap, Jean-François; Structural Morphology Group International Seminar 2011

    2011-01-01

    The first geometrical definitions of any structure are of primary importance when considering pertinence and efficiency in structural design processes. Engineering history has taught us how graphic statics can be a very powerful tool since it allows the designer to take shapes and forces into account simultaneously. However, current and past graphic statics methods are more suitable for analysis than structural morphogenesis. This contribution introduces new graphical methods that can supp...

  12. Static and Dynamic Strain Monitoring of Reinforced Concrete Components through Embedded Carbon Nanotube Cement-Based Sensors

    Directory of Open Access Journals (Sweden)

    Antonella D’Alessandro

    2017-01-01

    Full Text Available The paper presents a study on the use of cement-based sensors doped with carbon nanotubes as embedded smart sensors for static and dynamic strain monitoring of reinforced concrete (RC elements. Such novel sensors can be used for the monitoring of civil infrastructures. Because they are fabricated from a structural material and are easy to utilize, these sensors can be integrated into structural elements for monitoring of different types of constructions during their service life. Despite the scientific attention that such sensors have received in recent years, further research is needed to understand (i the repeatability and accuracy of sensors’ behavior over a meaningful number of sensors, (ii testing configurations and calibration methods, and (iii the sensors’ ability to provide static and dynamic strain measurements when actually embedded in RC elements. To address these research needs, this paper presents a preliminary characterization of the self-sensing capabilities and the dynamic properties of a meaningful number of cement-based sensors and studies their application as embedded sensors in a full-scale RC beam. Results from electrical and electromechanical tests conducted on small and full-scale specimens using different electrical measurement methods confirm that smart cement-based sensors show promise for both static and vibration-based structural health monitoring applications of concrete elements but that calibration of each sensor seems to be necessary.

  13. Research on micromanipulator’s clamping force sensing based on static wirerope tension of a surgical robot

    Directory of Open Access Journals (Sweden)

    Lingtao Yu

    2015-04-01

    Full Text Available The micromanipulator’s force feedback is one of the key research contents of minimally invasive surgical robotic system. Because the micromanipulator is a kind of compact construction which is suitable for valve installation with small space in surgery, especially for the influence of disinfection method, there are major difficulties and limitations to integrate compact sensors in the end of micromanipulator. This article focuses on the 3-degree-of-freedom micromanipulator’s clamping force sensing, and these three joints are actuated by wirerope driving. A clamping force sensing method is proposed based on static tension of wirerope driving, and a static model between the clamping force and wirerope’s static tension is established considering the influence of real friction resistance in the mechanical system. Finally, an equivalent experimental test platform for 3-degree-of-freedom micromanipulator’s clamping force sensing is set up, and then a series of experiments of the clamping force are studied. The frictional resistances of wirerope between the guide plate and guide pulley mechanism are tested, and a calibration and correction method of the experimental clamping force is proposed. The final experiment results show that the total average accuracy of experimental clamping force is about 78.3%, and it can be the basic measurement force to realize micromanipulator’s clamping force feedback of a minimally invasive surgical robot.

  14. The frozen face effect: why static photographs may not do you justice.

    Science.gov (United States)

    Post, Robert B; Haberman, Jason; Iwaki, Lica; Whitney, David

    2012-01-01

    When a video of someone speaking is paused, the stationary image of the speaker typically appears less flattering than the video, which contained motion. We call this the frozen face effect (FFE). Here we report six experiments intended to quantify this effect and determine its cause. In Experiment 1, video clips of people speaking in naturalistic settings as well as all of the static frames that composed each video were presented, and subjects rated how flattering each stimulus was. The videos were rated to be significantly more flattering than the static images, confirming the FFE. In Experiment 2, videos and static images were inverted, and the videos were again rated as more flattering than the static images. In Experiment 3, a discrimination task measured recognition of the static images that composed each video. Recognition did not correlate with flattery ratings, suggesting that the FFE is not due to better memory for particularly distinct images. In Experiment 4, flattery ratings for groups of static images were compared with those for videos and static images. Ratings for the video stimuli were higher than those for either the group or individual static stimuli, suggesting that the amount of information available is not what produces the FFE. In Experiment 5, videos were presented under four conditions: forward motion, inverted forward motion, reversed motion, and scrambled frame sequence. Flattery ratings for the scrambled videos were significantly lower than those for the other three conditions. In Experiment 6, as in Experiment 2, inverted videos and static images were compared with upright ones, and the response measure was changed to perceived attractiveness. Videos were rated as more attractive than the static images for both upright and inverted stimuli. Overall, the results suggest that the FFE requires continuous, natural motion of faces, is not sensitive to inversion, and is not due to a memory effect.

  15. The Frozen Face Effect: Why static photographs may not do you justice.

    Directory of Open Access Journals (Sweden)

    Robert ePost

    2012-02-01

    Full Text Available When a video of someone speaking is paused, the stationary image of the speaker typically appears less flattering than the video, which contained motion. We call this the Frozen Face Effect (FFE. Here we report six experiments intended to quantify this effect and determine its cause. In Experiment 1, video clips of people speaking in naturalistic settings as well as all of the static frames that composed each video were presented, and subjects rated how flattering each stimulus was. The videos were rated to be significantly more flattering than the static images, confirming the FFE. In Experiment 2, videos and static images were inverted, and the videos were again rated as more flattering than the static images. In Experiment 3, a discrimination task measured recognition of the static images that composed each video. Recognition did not correlate with flattery ratings, suggesting that the FFE is not due to better memory for particularly distinct images. In Experiment 4, flattery ratings for groups of static images were compared with those for videos and static images. Ratings for the video stimuli were higher than those for either the group or individual static stimuli, suggesting that the amount of information available is not what produces the FFE. In Experiment 5, videos were presented under four conditions: forward motion, inverted forward motion, reversed motion, and scrambled frame sequence. Flattery ratings for the scrambled videos were significantly lower than those for the other three conditions. In Experiment 6, as in Experiment 2, inverted videos and static images were compared with upright ones, and the response measure was changed to perceived attractiveness. Videos were rated as more attractive than the static images for both upright and inverted stimuli. Overall, the results suggest that the FFE requires continuous, natural motion of faces, is not sensitive to inversion, and is not due to a memory effect.

  16. New Systematic CFD Methods to Calculate Static and Single Dynamic Stability Derivatives of Aircraft

    Directory of Open Access Journals (Sweden)

    Bai-gang Mi

    2017-01-01

    Full Text Available Several new systematic methods for high fidelity and reliability calculation of static and single dynamic derivatives are proposed in this paper. Angle of attack step response is used to obtain static derivative directly; then translation acceleration dynamic derivative and rotary dynamic derivative can be calculated by employing the step response motion of rate of the angle of attack and unsteady motion of pitching angular velocity step response, respectively. Longitudinal stability derivative calculations of SACCON UCAV are taken as test cases for validation. Numerical results of all cases achieve good agreement with reference values or experiments data from wind tunnel, which indicate that the proposed methods can be considered as new tools in the process of design and production of advanced aircrafts for their high efficiency and precision.

  17. Novel Friction Law for the Static Friction Force based on Local Precursor Slipping

    OpenAIRE

    Katano, Yu; Nakano, Ken; Otsuki, Michio; Matsukawa, Hiroshi

    2014-01-01

    The sliding of a solid object on a solid substrate requires a shear force that is larger than the maximum static friction force. It is commonly believed that the maximum static friction force is proportional to the loading force and does not depend on the apparent contact area. The ratio of the maximum static friction force to the loading force is called the static friction coefficient µ M, which is considered to be a constant. Here, we conduct experiments demonstrating that the static fricti...

  18. Analysis of static and dynamic pile-soil-jacket behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Azadi, Mohammad Reza Emami

    1998-12-31

    In the offshore industry, recent extreme storms, severe earthquakes and subsidence of the foundation of jacket platforms have shown that new models and methods must take into account the jacket- pile-soil foundation interaction as well as the non-linear dynamic performance/loading effects. This thesis begins with a review of the state of art pile-soil interaction model, recognizing that most existing pile-soil models have been established based on large diameter pile tests on specific sites. The need for site independent and mechanistic pile-soil interaction models led to the development of new (t-z) and (p-y) disk models. These are validated using the available database from recent large diameter pile tests in the North Sea and Gulf of Mexico. The established static disk models are applied for non-linear static analysis of the jacket-pile-soil system under extreme wave loading. Dynamic pile-soil interaction is studied and a new disk-cone model is developed for the non-linear and non-homogeneous soils. This model is applied to both surface and embedded disks in a soil layer with non-linear properties. Simplified non-linear as well as more complex analysis methods are used to study the dynamic response of the jacket platform under extreme sea and seismic loading. Ductility spectra analysis is introduced and used to study the dynamic performance of the jacket systems near collapse. Case studies are used to illustrate the effects of structural, foundation failure characteristics as well as dynamic loading effects on the overall performance of the jacket-pile-soil systems near ultimate collapse. 175 refs., 429 figs., 70 tabs.

  19. Utsu aftershock productivity law explained from geometric operations on the permanent static stress field of mainshocks

    Science.gov (United States)

    Mignan, Arnaud

    2018-03-01

    The aftershock productivity law is an exponential function of the form K ∝ exp(αM), with K being the number of aftershocks triggered by a given mainshock of magnitude M and α ≈ ln(10) being the productivity parameter. This law remains empirical in nature although it has also been retrieved in static stress simulations. Here, we parameterize this law using the solid seismicity postulate (SSP), the basis of a geometrical theory of seismicity where seismicity patterns are described by mathematical expressions obtained from geometric operations on a permanent static stress field. We first test the SSP that relates seismicity density to a static stress step function. We show that it yields a power exponent q = 1.96 ± 0.01 for the power-law spatial linear density distribution of aftershocks, once uniform noise is added to the static stress field, in agreement with observations. We then recover the exponential function of the productivity law with a break in scaling obtained between small and large M, with α = 1.5ln(10) and ln(10), respectively, in agreement with results from previous static stress simulations. Possible biases of aftershock selection, proven to exist in epidemic-type aftershock sequence (ETAS) simulations, may explain the lack of break in scaling observed in seismicity catalogues. The existence of the theoretical kink, however, remains to be proven. Finally, we describe how to estimate the solid seismicity parameters (activation density δ+, aftershock solid envelope r∗ and background stress amplitude range Δo∗) for large M values.

  20. Computational Fluid Dynamics and Experimental Studies of a New Mixing Element in a Static Mixer as a Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Konopacki Maciej

    2015-03-01

    Full Text Available The main aim of this work is to study the thermal efficiency of a new type of a static mixer and to analyse the flow and temperature patterns and heat transfer efficiency. The measurements were carried out for the static mixer equipped with a new mixing insert. The heat transfer enhancement was determined by measuring the temperature profiles on each side of the heating pipe as well as the temperature field inside the static mixer. All experiments were carried out with varying operating parameters for four liquids: water, glycerol, transformer oil and an aqueous solution of molasses. Numerical CFD simulations were carried out using the two-equation turbulence k-ω model, provided by ANSYS Workbench 14.5 software. The proposed CFD model was validated by comparing the predicted numerical results against experimental thermal database obtained from the investigations. Local and global convective heat transfer coefficients and Nusselt numbers were detrmined. The relationship between heat transfer process and hydrodynamics in the static mixer was also presented. Moreover, a comparison of the thermal performance between the tested static mixer and a conventional empty tube was carried out. The relative enhancement of heat transfer was characterised by the rate of relative heat transfer intensification.

  1. Hanging an Airplane: A Case Study in Static Equilibrium

    Science.gov (United States)

    Katz, Debora M.

    2009-01-01

    Our classrooms are filled with engineering majors who take a semester-long course in static equilibrium. Many students find this class too challenging and drop their engineering major. In our introductory physics class, we often breeze through static equilibrium; to physicists equilibrium is just a special case of Newton's second law. While it is…

  2. Static Verification for Code Contracts

    Science.gov (United States)

    Fähndrich, Manuel

    The Code Contracts project [3] at Microsoft Research enables programmers on the .NET platform to author specifications in existing languages such as C# and VisualBasic. To take advantage of these specifications, we provide tools for documentation generation, runtime contract checking, and static contract verification.

  3. Static Analysis for Dynamic XML

    DEFF Research Database (Denmark)

    Christensen, Aske Simon; Møller, Anders; Schwartzbach, Michael Ignatieff

    2002-01-01

    We describe the summary graph lattice for dataflow analysis of programs that dynamically construct XML documents. Summary graphs have successfully been used to provide static guarantees in the JWIG language for programming interactive Web services. In particular, the JWIG compiler is able to check...

  4. Understanding students' concepts through guided inquiry learning and free modified inquiry on static fluid material

    OpenAIRE

    Sularso Sularso; Widha Sunarno; Sarwanto Sarwanto

    2017-01-01

    This study provides information on understanding students' concepts in guided inquiry learning groups and in free modified inquiry learning groups. Understanding of student concept is reviewed on the concept of static fluid case. The number of samples tested were 67 students. The sample is divided into 2 groups of students: the group is given guided inquiry learning and the group given the modified free inquiry learning. Understanding the concept of students is measured through 23 tests of it...

  5. Residual strength and crack propagation tests on C-130 airplane center wings with service-imposed fatigue damage

    Science.gov (United States)

    Snider, H. L.; Reeder, F. L.; Dirkin, W. J.

    1972-01-01

    Fourteen C-130 airplane center wings, each containing service-imposed fatigue damage resulting from 4000 to 13,000 accumulated flight hours, were tested to determine their fatigue crack propagation and static residual strength characteristics. Eight wings were subjected to a two-step constant amplitude fatigue test prior to static testing. Cracks up to 30 inches long were generated in these tests. Residual static strengths of these wings ranged from 56 to 87 percent of limit load. The remaining six wings containing cracks up to 4 inches long were statically tested as received from field service. Residual static strengths of these wings ranged from 98 to 117 percent of limit load. Damage-tolerant structural design features such as fastener holes, stringers, doublers around door cutouts, and spanwise panel splices proved to be effective in retarding crack propagation.

  6. Slipping and Tipping: Measuring Static Friction with a Straightedge

    Science.gov (United States)

    Dietz, Eric; Aguilar, Isaac

    2012-01-01

    Following a discussion of forces, torques, and the conditions for static equilibrium, I tell my introductory mechanics class that I will show them how to measure the coefficient of static friction, us, between the surfaces of a block and the front bench using "nothing but a straightedge". After a few seconds of hushed anticipation, I nudge the…

  7. Evaluation of static and dynamic fracture toughness in ductile cast iron

    International Nuclear Information System (INIS)

    Kobayashi, Toshiro; Yamada, Shinya

    1994-01-01

    Ductile cast irons have been explored as a cask (container for spent nuclear fuel) material because of their low cost and good formability. The cask, which is a huge casting with 400-mm thickness and 100-Mg weight, envelops the nuclear material. Therefore, the fracture toughness of cask must be evaluated not only under the static loading condition but also under the dynamic loading condition to ensure its safety against an accident during the transport. In this article, crack extension behavior and fracture toughness of ductile cast iron were examined by three-point bend tests, where various detection methods of crack initiation under static and dynamic loading conditions were adopted. Loading on the specimens was interrupted at various displacement points, and the final fracture surfaces of the specimen were observed via scanning electron microscopy (SEM). Crack-tip opening displacement (CTOD) obtained under the dynamic loading conditions was smaller than that under the static loading condition in ferritic ductile cast iron, and CTOD additionally decreased with increasing pearlite content in the matrix. The relationship between J(ΔC) obtained by the compliance changing rate method and J(R) established by the intersection of the crack extension resistance curve and the theoretical blunting line varied with pearlite content. The average value of J(ΔC) and J(R), that is J(mid), was proposed to define the fracture toughness of ductile cast iron; J(mid) was considered to be a reasonable measure for the fracture toughness of ductile cast iron, irrespective of loading condition and the pearlite content in the matrix

  8. Centrifuge modeling of rapid load tests with open-ended piles

    NARCIS (Netherlands)

    Nguyen, T.C.; Van Lottum, H.; Holscher, P.; Van Tol, A.F.

    2012-01-01

    Rapid and static load tests were conducted on open-ended and close-ended piles in the Deltares GeoCentriflige. hi flight, a pile was driven into the soil. Both fme-grained sand and silt beds were tested. Both the rapid and static soil resistances o f a close-ended pile were higher than the soil

  9. Static Scale Conversion Weigh-In-Motion System; FINAL

    International Nuclear Information System (INIS)

    Beshears, D.L.

    2001-01-01

    In support of the Air Mobility Battle Lab (AMBL), the Defense Advanced Research Projects Agency (DARPA) Advanced Logistics Program and the U. S. Transportation Command (USTRANSCOM), the ultimate objective of this project is to develop and demonstrate a full-scale prototype static scale conversion weigh-in-motion/Profilometry (SSC-WIM/P) system to measure and record dimensional and weight information for the Department of Defense (DoD) equipment and cargo. The Oak Ridge National Laboratory (ORNL), along with the AMBL, and Intercomp, Inc. have developed a long-range plan for developing a dual-use system which can be used as a standard static scale or an accurate weigh-in-motion system. AMBL will work to define requirements for additional activities with U.S. Transportation Command, Air Mobility Command, and the Joint Warfighting Battle Lab for both the SSC-WIM/P and a portable Weigh-in-Motion System for individual units. The funding goal is to fully fund the development of two prototype test articles (a SSC-WIM kit, and a laser profilometer) and have at least one fully operational system by the early 2002 timeframe. The objective of this portion of the project will be to develop a SSC-WIM system, which at a later date can be fully integrated with a profilometry system; to fully characterize DOD wheeled vehicles and cargo (individual axle weights, total vehicle weight, center of balance, height, width and length measurements). The program will be completed in phases with the initial AMBL/DARPA funding being used to initiate the efforts while AMBL/USTC obtains funding to complete the first generation system effort. At the completion of an initial effort, the interface hardware and the data acquisition/analysis hardware will be developed, fabricated, and system principles and basic functionality evaluated, tested, and demonstrated. Additional funding, when made available, will allow the successful completion of a first generation prototype system. This effort will be

  10. The effect of shoe type on static and dynamic balance during treadmill walking in young healthy women.

    Science.gov (United States)

    Kim, Mi-Kyoung; Kong, Byung-Sun; Yoo, Kyung-Tae

    2017-09-01

    [Purpose] The purpose of this study was to analyze the effect of various shoes on the static and dynamic balance of young women in their 20s. [Subjects and Methods] The subjects of the study were 15 healthy young women and repeated measured design. The subjects walked on the treadmill at a speed of 4 km/h for 30 minutes wearing three types of shoes: sneaker, rain boots, and combat boots. Balance was measured by a Romberg test and a limits of stability test. One-way ANOVA was used for statistical analysis. [Results] As the results of the Romberg test, the main effect of time was shown in the EO-COG area, EO-COG length, and EO-COG velocity. As the results of the limits of stability test, the main effects of time in LT, RT, FW, and total. There were significant differences in the LT in the sneaker group, the rain boots group, and the LT and RT in the combat boots group between the pre- and post-test. [Conclusion] The characteristics of shoes such as the materials, hardness, and thickness of the soles, the coefficient of friction of the outsoles, and the collar height affected the static and dynamic balance.

  11. Identification of a Critical Time with Acoustic Emission Monitoring during Static Fatigue Tests on Ceramic Matrix Composites: Towards Lifetime Prediction

    Directory of Open Access Journals (Sweden)

    Nathalie Godin

    2016-02-01

    Full Text Available Non-oxide fiber-reinforced ceramic-matrix composites are promising candidates for some aeronautic applications that require good thermomechanical behavior over long periods of time. This study focuses on the behavior of a SiCf/[Si-B-C] composite with a self-healing matrix at intermediate temperature under air. Static fatigue experiments were performed below 600 °C and a lifetime diagram is presented. Damage is monitored both by strain measurement and acoustic emission during the static fatigue experiments. Two methods of real-time analysis of associated energy release have been developed. They allow for the identification of a characteristic time that was found to be close to 55% of the measured rupture time. This critical time reflects a critical local energy release assessed by the applicability of the Benioff law. This critical aspect is linked to a damage phase where slow crack growth in fibers is prevailing leading to ultimate fracture of the composite.

  12. Static Analysis of Functional Programs

    NARCIS (Netherlands)

    van den Berg, Klaas; van den Broek, P.M.

    1994-01-01

    In this paper, the static analysis of programs in the functional programming language Miranda is described based on two graph models. A new control-flow graph model of Miranda definitions is presented, and a model with four classes of caligraphs. Standard software metrics are applicable to these

  13. AERODYNAMIC STUDIES IN THE STATIC COMPONENTS OF A CENTRIFUGAL COMPRESSOR STAGE

    Directory of Open Access Journals (Sweden)

    K. Srinivasa Reddy

    2011-12-01

    Full Text Available Aerodynamic studies in the static components of a centrifugal compressor stage were conducted using the computational fluid dynamics solver FLUENT. For the simulation study, a typical centrifugal compressor stage geometry with a flow coefficient of 0.053 was chosen, The study is confined to the static components of the centrifugal compressor stage, i.e., the crossover bend (180° U-bend, a radial cascade of return channel vanes, and the exit ducting (90° L-turn. The aerodynamic performance is reported in terms of total pressure loss coefficient, static pressure recovery coefficient, return channel vane surface static pressure distribution, and stage exit swirl angle distribution. The simulated flow through the static components covered five different operating conditions of the actual centrifugal compressor stage: the design point with 100% flow rate, and the off-design operating conditions with 70%, 80%, 110%, and 120% flow rates. The standard k-ε model was used with standard wall functions to predict the turbulence. A minimum total pressure loss coefficient was observed near 80% flow rate when the average flow angle at the U-bend inlet was 24°. Better static pressure recovery was observed with 70%, 80%, and 100% flow rates. The swirl angle distribution at the stage exit was recognized as satisfactory.

  14. Cylindrically symmetric, static strings with a cosmological constant in Brans-Dicke theory

    International Nuclear Information System (INIS)

    Delice, Oezguer

    2006-01-01

    The static cylindrically symmetric vacuum solutions with a cosmological constant in the framework of the Brans-Dicke theory are investigated. Some of these solutions admitting Lorentz boost invariance along the symmetry axis correspond to local, straight cosmic strings with a cosmological constant. Some physical properties of such solutions are studied. These strings apply attractive or repulsive forces on the test particles. A smooth matching is also performed with a recently introduced interior thick string solution with a cosmological constant

  15. Concussion History and Time Since Concussion Do not Influence Static and Dynamic Balance in Collegiate Athletes.

    Science.gov (United States)

    Merritt, Eric D; Brown, Cathleen N; Queen, Robin M; Simpson, Kathy J; Schmidt, Julianne D

    2017-11-01

    Dynamic balance deficits exist following a concussion, sometimes years after injury. However, clinicians lack practical tools for assessing dynamic balance. To determine if there are significant differences in static and dynamic balance performance between individuals with and without a history of concussion. Cross sectional. Clinical research laboratory. 45 collegiate student-athletes with a history of concussion (23 males, 22 females; age = 20.0 ± 1.4 y; height = 175.8 ± 11.6 cm; mass = 76.4 ± 19.2 kg) and 45 matched controls with no history of concussion (23 males, 22 females; age = 20.0 ± 1.3 y; height = 178.8 ± 13.2 cm; mass = 75.7 ± 18.2 kg). Participants completed a static (Balance Error Scoring System) and dynamic (Y Balance Test-Lower Quarter) balance assessment. A composite score was calculated from the mean normalized Y Balance Test-Lower Quarter reach distances. Firm, foam, and overall errors were counted during the Balance Error Scoring System by a single reliable rater. One-way ANOVAs were used to compare balance performance between groups. Pearson's correlations were performed to determine the relationship between the time since the most recent concussion and balance performance. A Bonferonni adjusted a priori α balance performance did not significantly differ between groups. No significant correlation was found between the time since the most recent concussion and balance performance. Collegiate athletes with a history of concussion do not present with static or dynamic balance deficits when measured using clinical assessments. More research is needed to determine whether the Y Balance Test-Lower Quarter is sensitive to acute balance deficits following concussion.

  16. A cumulant functional for static and dynamic correlation

    International Nuclear Information System (INIS)

    Hollett, Joshua W.; Hosseini, Hessam; Menzies, Cameron

    2016-01-01

    A functional for the cumulant energy is introduced. The functional is composed of a pair-correction and static and dynamic correlation energy components. The pair-correction and static correlation energies are functionals of the natural orbitals and the occupancy transferred between near-degenerate orbital pairs, rather than the orbital occupancies themselves. The dynamic correlation energy is a functional of the statically correlated on-top two-electron density. The on-top density functional used in this study is the well-known Colle-Salvetti functional. Using the cc-pVTZ basis set, the functional effectively models the bond dissociation of H 2 , LiH, and N 2 with equilibrium bond lengths and dissociation energies comparable to those provided by multireference second-order perturbation theory. The performance of the cumulant functional is less impressive for HF and F 2 , mainly due to an underestimation of the dynamic correlation energy by the Colle-Salvetti functional.

  17. Size scaling of static friction.

    Science.gov (United States)

    Braun, O M; Manini, Nicola; Tosatti, Erio

    2013-02-22

    Sliding friction across a thin soft lubricant film typically occurs by stick slip, the lubricant fully solidifying at stick, yielding and flowing at slip. The static friction force per unit area preceding slip is known from molecular dynamics (MD) simulations to decrease with increasing contact area. That makes the large-size fate of stick slip unclear and unknown; its possible vanishing is important as it would herald smooth sliding with a dramatic drop of kinetic friction at large size. Here we formulate a scaling law of the static friction force, which for a soft lubricant is predicted to decrease as f(m)+Δf/A(γ) for increasing contact area A, with γ>0. Our main finding is that the value of f(m), controlling the survival of stick slip at large size, can be evaluated by simulations of comparably small size. MD simulations of soft lubricant sliding are presented, which verify this theory.

  18. Statics of historic masonry constructions

    CERN Document Server

    Como, Mario

    2016-01-01

    This successful book, which is now appearing in its second edition, presents a comprehensive new Statics of Masonry Constructions. Masonry constructions are the great majority of the buildings in Europe’s historic centres and the most important monuments in its architectural heritage. Given the age of these constructions, the demand for safety assessments and restoration projects is pressing and constant. The book you hold in hands contributes to fill this demand. The second edition integrates the original text of the first edition with new developments, widening and revisions, due to recent research studies achievements. The result is a book that gives a complete picture of the behaviour of the Masonry Constructions. First of all, it gives the fundamentals of its Statics, based on the no-tension assumption, and then it develops the Limit Analysis for the Masonry Constructions. In this framework, through an interdisciplinary approach combining Engineering and Architecture, the book also investigates the sta...

  19. Hubble expansion in static spacetime

    International Nuclear Information System (INIS)

    Rossler, Otto E.; Froehlich, Dieter; Movassagh, Ramis; Moore, Anthony

    2007-01-01

    A recently proposed mechanism for light-path expansion in a static spacetime is based on the moving-lenses paradigm. Since the latter is valid independently of whether space expands or not, a static universe can be used to better see the implications. The moving-lenses paradigm is related to the paradigm of dynamical friction. If this is correct, a Hubble-like law is implicit. It is described quantitatively. A bent in the Hubble-like line is predictably implied. The main underlying assumption is Price's Principle (PI 3 ). If the theory is sound, the greatest remaining problem in cosmology becomes the origin of hydrogen. Since Blandford's jet production mechanism for quasars is too weak, a generalized Hawking radiation hidden in the walls of cosmic voids is invoked. A second prediction is empirical: slow pattern changes in the cosmic microwave background. A third is ultra-high redshifts for Giacconi quasars. Bruno's eternal universe in the spirit of Augustine becomes a bit less outlandish

  20. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    OpenAIRE

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests a...

  1. Vrancea slab earthquakes triggered by static stress transfer

    Directory of Open Access Journals (Sweden)

    A. Ganas

    2010-12-01

    Full Text Available The purpose of this paper is to study the interaction of the Vrancea seismic activity (Romania in space as result of Coulomb, static stress transfer during M=7+ events. In this area, three large events occurred in 1977, 1986 and 1990 at mid-lower, lithospheric depths and with similar focal mechanisms. Assuming elastic rheology for the deforming rocks it is suggested that frictional sliding on pre-existing fault produced the 1986 M=7.1 event (depth 131 km, that was possibly triggered by the 1977 M=7.4 event (depth 94 km. We calculated a static stress transfer of 0.52–0.78 bar to the hypocentre of the 1986 event. On the contrary, the occurrence of the 1990 event is uncertain: it is located inside the relaxed (shadow zone of the combined 1977 and 1986 static stress field considering an azimuth for maximum compression of N307° E. It follows that, the 1990 earthquake most likely represents an unbroken patch (asperity of the 1977 rupture plane that failed due to loading. However, if a different compression azimuth is assumed (N323° E then the 1990 event was also possibly triggered by static stress transfer of the 1977 and 1986 events (combined. Our modeling is a first-order approximation of the kind of earthquake interaction we might expect at intermediate lithospheric depths (80–90 to 130–140 km. It is also suggested that static stress transfer may explain the clustering of Vrancea earthquakes in space by the rupturing of two (possibly three NW-dipping major zones of weakness (faults which accommodate the extension (vertical elongation of the slab.

  2. Dynamic path planning for autonomous driving on various roads with avoidance of static and moving obstacles

    Science.gov (United States)

    Hu, Xuemin; Chen, Long; Tang, Bo; Cao, Dongpu; He, Haibo

    2018-02-01

    This paper presents a real-time dynamic path planning method for autonomous driving that avoids both static and moving obstacles. The proposed path planning method determines not only an optimal path, but also the appropriate acceleration and speed for a vehicle. In this method, we first construct a center line from a set of predefined waypoints, which are usually obtained from a lane-level map. A series of path candidates are generated by the arc length and offset to the center line in the s - ρ coordinate system. Then, all of these candidates are converted into Cartesian coordinates. The optimal path is selected considering the total cost of static safety, comfortability, and dynamic safety; meanwhile, the appropriate acceleration and speed for the optimal path are also identified. Various types of roads, including single-lane roads and multi-lane roads with static and moving obstacles, are designed to test the proposed method. The simulation results demonstrate the effectiveness of the proposed method, and indicate its wide practical application to autonomous driving.

  3. A comparative study of the effect of soft and hard cervical collars on static postural

    Directory of Open Access Journals (Sweden)

    Minoo Khalkhali Zavieh

    2013-01-01

    Full Text Available AbstractBackground and Aim: Using cervical collars is one of the treatment methods for releaving cervical pain. The effect of limb orthotics on proprioception and postural stability has been suggested. There is not sufficient studies about the effect of cervical collars on static and dynamic stability, and the effect of soft and hard collars have not been compared with one another. The objective of this study is investigating and comparing the immediate effect of soft and hard cervical collars on static postural stability in healthy young subjects. Methods & Materials: In standing position on firm surface with closed eyes, both soft and hard collars decreased the stability and there was not any significant difference among collars. In standing positions on soft surface with closed and opened eyes, using none of the soft and hard collars did not change the stability. This quasi experimental study through repeated measure method has been conducted on 65 healthy young male and female college students. Static stability was evaluated by modified Clinical Test for Sensory Interaction and Balance (CTSIB in conditions without collar and by soft and hard cervical collars and were compared between the conditions. Results: Conclusion: Our results suggest that in static conditions, without vision, both collars decrease the stability in healthy young subjects. So considering the evaluation of stability and prevention of balance disturbance during the collar prescription seems to be necessary.

  4. Geomagnetic and strong static magnetic field effects on growth and chlorophyll a fluorescence in Lemna minor.

    Science.gov (United States)

    Jan, Luka; Fefer, Dušan; Košmelj, Katarina; Gaberščik, Alenka; Jerman, Igor

    2015-04-01

    The geomagnetic field (GMF) varies over Earth's surface and changes over time, but it is generally not considered as a factor that could influence plant growth. The effects of reduced and enhanced GMFs and a strong static magnetic field on growth and chlorophyll a (Chl a) fluorescence of Lemna minor plants were investigated under controlled conditions. A standard 7 day test was conducted in extreme geomagnetic environments of 4 µT and 100 µT as well as in a strong static magnetic field environment of 150 mT. Specific growth rates as well as slow and fast Chl a fluorescence kinetics were measured after 7 days incubation. The results, compared to those of controls, showed that the reduced GMF significantly stimulated growth rate of the total frond area in the magnetically treated plants. However, the enhanced GMF pointed towards inhibition of growth rate in exposed plants in comparison to control, but the difference was not statistically significant. This trend was not observed in the case of treatments with strong static magnetic fields. Our measurements suggest that the efficiency of photosystem II is not affected by variations in GMF. In contrast, the strong static magnetic field seems to have the potential to increase initial Chl a fluorescence and energy dissipation in Lemna minor plants. © 2015 Wiley Periodicals, Inc.

  5. The assessment of static balance in children with hearing, visual and intellectual disabilities

    Directory of Open Access Journals (Sweden)

    Aija Klavina

    2017-10-01

    Full Text Available Background: Balance is a fundamental part of many movement tasks a child performs. Maintaining upright posture is a complex process involving multiple body parts and functional systems. Objective: This study aimed to explore the mean amplitude and velocity of the center of pressure (COP displacements during static balance tests in children with and without disabilities. Methods: Participants were 34 children (age 8.5 to 10.8 years including 6 typically developed children, 8 children with hearing, 8 children with visual and 12 children with intellectual disabilities. Static balance data were obtained in 15 s bipedal stance with eyes open and eyes closed, and also in 10 s unipedal stance. A force plate was used to collect data of COP amplitude in anterior-posterior (COPA-P, medio-lateral (COPM-L directions and COP velocity (COPV. Results: Study outcomes revealed that all subgroups presented larger COP displacement and velocity with eyes closed (p < .001. During bipedal stance with eyes open for results of COPM-L and COPV no significant differences were found between children with and without disabilities (p > .05. Children with intellectual and visual impairments presented significantly larger displacement in COPA-P and COPM-L in comparison with children with hearing impairment and without disability (p < .05. Conclusions: This study provided evidence of comparative outcomes on static stability assessment in elementary school children with and without disability. While in many test items children with disability did not demonstrate a significantly decreased level of postural control outcomes comparing to their peers without disability, the balance assessment should be used for early detection of dysfunction in children, so as to guide the application of appropriate intervention.

  6. An eight-legged tactile sensor to estimate coefficient of static friction.

    Science.gov (United States)

    Wei Chen; Rodpongpun, Sura; Luo, William; Isaacson, Nathan; Kark, Lauren; Khamis, Heba; Redmond, Stephen J

    2015-08-01

    It is well known that a tangential force larger than the maximum static friction force is required to initiate the sliding motion between two objects, which is governed by a material constant called the coefficient of static friction. Therefore, knowing the coefficient of static friction is of great importance for robot grippers which wish to maintain a stable and precise grip on an object during various manipulation tasks. Importantly, it is most useful if grippers can estimate the coefficient of static friction without having to explicitly explore the object first, such as lifting the object and reducing the grip force until it slips. A novel eight-legged sensor, based on simplified theoretical principles of friction is presented here to estimate the coefficient of static friction between a planar surface and the prototype sensor. Each of the sensor's eight legs are straight and rigid, and oriented at a specified angle with respect to the vertical, allowing it to estimate one of five ranges (5 = 8/2 + 1) that the coefficient of static friction can occupy. The coefficient of friction can be estimated by determining whether the legs have slipped or not when pressed against a surface. The coefficients of static friction between the sensor and five different materials were estimated and compared to a measurement from traditional methods. A least-squares linear fit of the sensor estimated coefficient showed good correlation with the reference coefficient with a gradient close to one and an r(2) value greater than 0.9.

  7. Whole-lung volume and density in spirometrically-gated inspiratory and expiratory CT in systemic sclerosis: correlation with static volumes at pulmonary function tests.

    Science.gov (United States)

    Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M

    2013-03-01

    Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.

  8. Static Analysis for Systems Biology

    DEFF Research Database (Denmark)

    Nielson, Flemming; Nielson, Hanne Riis; Rosa, D. Schuch da

    2004-01-01

    This paper shows how static analysis techniques can help understanding biological systems. Based on a simple example we illustrate the outcome of performing three different analyses extracting information of increasing precision. We conclude by reporting on the potential impact and exploitation o...... of these techniques in systems biology....

  9. Effects of a static electric field on two-color photoassociation between different atoms

    International Nuclear Information System (INIS)

    Chakraborty, Debashree; Deb, Bimalendu

    2014-01-01

    We study non-perturbative effects of a static electric field on two-color photoassociation of different atoms. A static electric field induces anisotropy in scattering between two different atoms and hybridizes field-free rotational states of heteronuclear dimers or polar molecules. In a previous paper [D. Chakraborty et al., J. Phys. B 44, 095201 (2011)], the effects of a static electric field on one-color photoassociation between different atoms has been described through field-modified ground-state scattering states, neglecting electric field effects on heteronuclear diatomic bound states. To study the effects of a static electric field on heteronuclear bound states, and the resulting influence on Raman-type two-color photoassociation between different atoms in the presence of a static electric field, we develop a non-perturbative numerical method to calculate static electric field-dressed heteronuclear bound states. We show that the static electric field induced scattering anisotropy as well as hybridization of rotational states strongly influence two-color photoassociation spectra, leading to significant enhancement in PA rate and large shift. In particular, for static electric field strengths of a few hundred kV/cm, two-color PA rate involving high-lying bound states in electronic ground-state increases by several orders of magnitude even in the weak photoassociative coupling regime

  10. Strength training in elderly people improves static balance: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Sarabon Nejc

    2013-07-01

    Full Text Available Aim of this study was to investigate the effects of two different types of strength training programs on static balance in elderly subjects. Subjects older than 65 years of age were enrolled and assigned to control group (CG, n =19, electrical stimulation group (ES, n = 27 or leg press group (LP, n = 28. Subjects in both the training groups were exposed to training (2-3x/week for a period of 9 weeks. In the ES group the subjects received neuromuscular electrical stimulation of the anterior thigh muscles. In the LP group the subjects performed strength training on a computer-controlled leg press machine. Before and after the training period, static balance of the subject was tested using a quiet stance task. Average velocity, amplitude and frequency of the center-of-pressure (CoP were calculated from the acquired force plate signal. The data was statistically tested with analysis of (covariance and t-tests. The three groups of subjects showed statistically significant differences (p < 0.05 regarding the pre-training vs. post-training changes in CoP velocity, amplitude and frequency. The differences were more pronounced for CoP velocity and amplitude, while they were less evident in case of mean frequency. The mean improvements were higher in the LP group than in the ES group. Our results provide supportive evidence to the existence of the strength-balance relationship. Additionally, results indicate the role of recruiting central processes and activation of functional kinetic chains for the better end effect.

  11. Towards a formal definition of static and dynamic electronic correlations.

    Science.gov (United States)

    Benavides-Riveros, Carlos L; Lathiotakis, Nektarios N; Marques, Miguel A L

    2017-05-24

    Some of the most spectacular failures of density-functional and Hartree-Fock theories are related to an incorrect description of the so-called static electron correlation. Motivated by recent progress in the N-representability problem of the one-body density matrix for pure states, we propose a method to quantify the static contribution to the electronic correlation. By studying several molecular systems we show that our proposal correlates well with our intuition of static and dynamic electron correlation. Our results bring out the paramount importance of the occupancy of the highest occupied natural spin-orbital in such quantification.

  12. Contagion processes on the static and activity-driven coupling networks

    Science.gov (United States)

    Lei, Yanjun; Jiang, Xin; Guo, Quantong; Ma, Yifang; Li, Meng; Zheng, Zhiming

    2016-03-01

    The evolution of network structure and the spreading of epidemic are common coexistent dynamical processes. In most cases, network structure is treated as either static or time-varying, supposing the whole network is observed in the same time window. In this paper, we consider the epidemics spreading on a network which has both static and time-varying structures. Meanwhile, the time-varying part and the epidemic spreading are supposed to be of the same time scale. We introduce a static and activity-driven coupling (SADC) network model to characterize the coupling between the static ("strong") structure and the dynamic ("weak") structure. Epidemic thresholds of the SIS and SIR models are studied using the SADC model both analytically and numerically under various coupling strategies, where the strong structure is of homogeneous or heterogeneous degree distribution. Theoretical thresholds obtained from the SADC model can both recover and generalize the classical results in static and time-varying networks. It is demonstrated that a weak structure might make the epidemic threshold low in homogeneous networks but high in heterogeneous cases. Furthermore, we show that the weak structure has a substantive effect on the outbreak of the epidemics. This result might be useful in designing some efficient control strategies for epidemics spreading in networks.

  13. Relationship between the medial longitudinal arch and the thoracic and lumbar curvatures with the static and dynamic stability in obese females

    Directory of Open Access Journals (Sweden)

    Abbas Rahimi

    2012-07-01

    Full Text Available Background and Aim: Reviewing the literature reveals a possible correlation between the obesity and the potential foot, spine and stability problems. Investigating the important parameters affecting the balance of obese people and prevention from falling are of high importance to reduce the resulting expenditures. This study aimed to assess the acts and the counter acts between the medial longitudinal arch (MLA and the thoracic and lumbar curvatures with the static and dynamic stability in obese females. Materials and Methods: Twenty eight obese females (age= 25±8 years old, BMI=37±4 and twenty nine non-obese females (age= 23±4 years old, BMI=23±3 were recruited in this case-control study with the cross-sectional technique. The MLA, spinal curve angles and the static or dynamic balance index of the subjects were measured using the navicular drop, flexible ruler and Biodex balance system tools, respectively. The static balance test was carried out using a modified Clinical Test of Sensory Interaction and Balance (CTSIB test in both the open and closed eyes while the subjects stood on their dominant legs. The order of the dynamic and static tests was selected randomly.Results: The findings of this study showed that in closed eye condition, most changes happened between the global Stability Index (SI and BMI; while in open eye condition, most changes occurred between the lateral-medial stability index and BMI (r=0.5. Also during an open eye condition, a moderate correlation was found between the navicular drop and lateral-medial stability index (r=0.05. In closed eyes condition, no significant changes were found between the SI and lumbar lordosis (r=0.0004; while a weak correlation was found between the thoracic curve angle and lateral-medial stability index (r=0.04.Conclusion: The dynamic stability is not only correlated to their BMI, but is highly dependent on their foot curvature types and slightly on their thoracic curve angle. Abdominal

  14. Java bytecode verification via static single assignment form

    DEFF Research Database (Denmark)

    Gal, Andreas; Probst, Christian W.; Franz, Michael

    2008-01-01

    Java Virtual Machines (JVMs) traditionally perform bytecode verification by way of an iterative data-flow analysis. Bytecode verification is necessary to ensure type safety because temporary variables in the JVM are not statically typed. We present an alternative verification mechanism that trans......Java Virtual Machines (JVMs) traditionally perform bytecode verification by way of an iterative data-flow analysis. Bytecode verification is necessary to ensure type safety because temporary variables in the JVM are not statically typed. We present an alternative verification mechanism...

  15. Newton gauge cosmological perturbations for static spherically symmetric modifications of the de Sitter metric

    Science.gov (United States)

    Santa Vélez, Camilo; Enea Romano, Antonio

    2018-05-01

    Static coordinates can be convenient to solve the vacuum Einstein's equations in presence of spherical symmetry, but for cosmological applications comoving coordinates are more suitable to describe an expanding Universe, especially in the framework of cosmological perturbation theory (CPT). Using CPT we develop a method to transform static spherically symmetric (SSS) modifications of the de Sitter solution from static coordinates to the Newton gauge. We test the method with the Schwarzschild de Sitter (SDS) metric and then derive general expressions for the Bardeen's potentials for a class of SSS metrics obtained by adding to the de Sitter metric a term linear in the mass and proportional to a general function of the radius. Using the gauge invariance of the Bardeen's potentials we then obtain a gauge invariant definition of the turn around radius. We apply the method to an SSS solution of the Brans-Dicke theory, confirming the results obtained independently by solving the perturbation equations in the Newton gauge. The Bardeen's potentials are then derived for new SSS metrics involving logarithmic, power law and exponential modifications of the de Sitter metric. We also apply the method to SSS metrics which give flat rotation curves, computing the radial energy density profile in comoving coordinates in presence of a cosmological constant.

  16. The Design and Development of Driving Game as an Evaluation Instrument for Driving License Test

    OpenAIRE

    Abdul Hadi Abdul Razak; Mohd Hairy Manap

    2013-01-01

    The focus of this paper is to highlight the design and development of an educational game prototype as an evaluation instrument for the Malaysia driving license static test. This educational game brings gaming technology into the conventional objective static test to make it more effective, real and interesting. From the feeling of realistic, the future driver can learn something, memorized and use it in the real life. The current online objective static test only make th...

  17. Static Progressive Orthoses for Elbow Contracture: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Bin Chen

    2017-01-01

    Full Text Available Background. As one of the most common musculoskeletal complications following trauma, elbow contracture is a frequent source of disabled daily activities. Conventional interventions are inadequate to provide favorable outcome. The static progressive orthoses are getting popular in the treatment of this problem. Objective. The purpose of this review was to assess the effectiveness of static progressive orthoses for elbow contracture. Methods. Literatures when written in English published during 1 January 1997 and 31 January 2017 were searched in the following databases: Web of Science, Cochrane Library, PubMed, and EBSCOhost. Articles are quality-assessed by two assessors, each article was summarized in evidence tables, and a narrative synthesis was also performed. Results. Ten clinical trials were included. The study design and outcome measures used varied. Significant immediate improvement in the range of motion was reported by all studies, and those effects were still significant at follow-up. No significant difference was shown between static progressive and dynamic orthoses for elbow contracture in one randomized control trial. Conclusions. Current low-quality evidence suggested that static progressive orthoses provided assistance for elbow contracture through improving range of motion. Further research is recommended using high-quality randomized controlled trials.

  18. Supporting secure programming in web applications through interactive static analysis.

    Science.gov (United States)

    Zhu, Jun; Xie, Jing; Lipford, Heather Richter; Chu, Bill

    2014-07-01

    Many security incidents are caused by software developers' failure to adhere to secure programming practices. Static analysis tools have been used to detect software vulnerabilities. However, their wide usage by developers is limited by the special training required to write rules customized to application-specific logic. Our approach is interactive static analysis, to integrate static analysis into Integrated Development Environment (IDE) and provide in-situ secure programming support to help developers prevent vulnerabilities during code construction. No additional training is required nor are there any assumptions on ways programs are built. Our work is motivated in part by the observation that many vulnerabilities are introduced due to failure to practice secure programming by knowledgeable developers. We implemented a prototype interactive static analysis tool as a plug-in for Java in Eclipse. Our technical evaluation of our prototype detected multiple zero-day vulnerabilities in a large open source project. Our evaluations also suggest that false positives may be limited to a very small class of use cases.

  19. A curved beam test specimen for determining the interlaminar tensile strength of a laminated composite

    Science.gov (United States)

    Hiel, Clement C.; Sumich, Mark; Chappell, David P.

    1991-01-01

    A curved beam type of test specimen is evaluated for use in determining the through-the-thickness strength of laminated composites. Two variations of a curved beam specimen configuration (semicircular and elliptical) were tested to failure using static and fatigue loads. The static failure load for the semicircular specimens was found to be highly sensitive to flaw content, with the specimens falling into two distinct groups. This result supports the use of proof testing for structural validation. Static design allowables are derived based on the Weibull distribution. Fatigue data indicates no measured increase in specimen compliance prior to final fracture. All static and fatigue failures at room temperature dry conditions occurred catastrophically. The elliptical specimens demonstrated unusually high failure strengths indicating the presence of phenomena requiring further study. Results are also included for specimens exposed to a wet environment showing a matrix strength degradation due to moisture content. Further testing is underway to evaluate a fatigue methodology for matrix dominated failures based on residual static strength (wearout).

  20. Bi-conformal symmetry and static Green functions in the Schwarzschild-Tangherlini spacetimes

    International Nuclear Information System (INIS)

    Frolov, Valeri P.; Zelnikov, Andrei

    2015-01-01

    We study a static massless minimally coupled scalar field created by a source in a static D-dimensional spacetime. We demonstrate that the corresponding equation for this field is invariant under a special transformation of the background metric. This transformation consists of the static conformal transformation of the spatial part of the metric accompanied by a properly chosen transformation of the red-shift factor. Both transformations are determined by one function Ω of the spatial coordinates. We show that in a case of higher dimensional spherically symmetric black holes one can find such a bi-conformal transformation that the symmetry of the D-dimensional metric is enhanced after its application. Namely, the metric becomes a direct sum of the metric on a unit sphere and the metric of 2D anti-de Sitter space. The method of the heat kernels is used to find the Green function in this new space, which allows one, after dimensional reduction, to obtain a static Green function in the original space of the static black hole. The general useful representation of static Green functions is obtained in the Schwarzschild-Tangherlini spacetimes of arbitrary dimension. The exact explicit expressions for the static Green functions are obtained in such metrics for D<6. It is shown that in the four dimensional case the corresponding Green function coincides with the Copson solution.

  1. Fracture Testing with Surface Crack Specimens. [especially the residual tensile strength test

    Science.gov (United States)

    Orange, T. W.

    1974-01-01

    Recommendations are given for the design, preparation, and static fracture testing of surface crack specimens. The recommendations are preceded by background information including discussions of stress intensity factors, crack opening displacements, and fracture toughness values associated with surface crack specimens. Cyclic load and sustained load tests are discussed briefly.

  2. A materials test system for static compression at elevated temperatures

    Science.gov (United States)

    Korellis, J. S.; Steinhaus, C. A.; Totten, J. J.

    1992-06-01

    This report documents modifications to our existing computer-controlled compression testing system to allow elevated temperature testing in an evacuated environment. We have adopted an 'inverse' design configuration where the evacuated test volume is located within the induction heating coil, eliminating the expense and minimizing the evacuation time of a much larger traditional vacuum chamber.

  3. Static and dynamical properties of light hadrons in QCD

    International Nuclear Information System (INIS)

    Ioffe, B.L.

    1984-01-01

    The review of QCD determination of static and dynamical properties of hadrons is given. Hadron masses, their transition constants into quark currents, meson formfactors at intermediate momentum transfers, mesonic partial widths and structure functions at small x are considered. A special attention is paid to calculation of static paramaters of hadrons in external fields (nucleon and hyperon magnetic moments, interaction constants with axial currents)

  4. CONTINUOUS PRODUCTION OF HYDROXYPROPYL STARCH IN A STATIC MIXER REACTOR

    NARCIS (Netherlands)

    LAMMERS, G; STAMHUIS, EJ; BEENACKERS, AACM

    A novel type of reactor for the chemical derivatization of starch pastes is presented. The design is based on the application of static mixers. The reactor shows excellent plug flow behaviour with a Peclet number of about 100. The viscosity behaviour of concentrated starch pastes in the static mixer

  5. Static harmonization of dynamically harmonized Fourier transform ion cyclotron resonance cell.

    Science.gov (United States)

    Zhdanova, Ekaterina; Kostyukevich, Yury; Nikolaev, Eugene

    2017-08-01

    Static harmonization in the Fourier transform ion cyclotron resonance cell improves the resolving power of the cell and prevents dephasing of the ion cloud in the case of any trajectory of the charged particle, not necessarily axisymmetric cyclotron (as opposed to dynamic harmonization). We reveal that the Fourier transform ion cyclotron resonance cell with dynamic harmonization (paracell) is proved to be statically harmonized. The volume of the statically harmonized potential distribution increases with an increase in the number of trap segments.

  6. Performance characterization of VGCF/epoxy nanocomposite sensors under static load cycles and in static structural health monitoring

    International Nuclear Information System (INIS)

    Hu, Bin; Hu, Ning; Cai, Yindi; Furukawa, Manabu; Matsushita, Makoto; Yuan, Weifeng; Cai, Yong; Yan, Cheng

    2013-01-01

    Compared to conventional metal-foil strain gauges, nanocomposite piezoresistive strain sensors have demonstrated high strain sensitivity and have been attracting increasing attention in recent years. To fulfil their ultimate success, the performance of vapor growth carbon fiber (VGCF)/epoxy nanocomposite strain sensors subjected to static cyclic loads was evaluated in this work. A strain-equivalent quantity (resistance change ratio) in cantilever beams with intentionally induced notches in bending was evaluated using the conventional metal-foil strain gauges and the VGCF/epoxy nanocomposite sensors. Compared to the metal-foil strain gauges, the nanocomposite sensors are much more sensitive to even slight structural damage. Therefore, it was confirmed that the signal stability, reproducibility, and durability of these nanocomposite sensors are very promising, leading to the present endeavor to apply them for static structural health monitoring. (paper)

  7. Quantitative static scintigraphy for the evaluation of mucociliary clearance

    International Nuclear Information System (INIS)

    Maini, C.L.; Marchetti, L.; Giordano, A.; Antonelli Incalzi, R.; Fuso, L.

    1988-01-01

    Mucociliary clearance can be evaluated by radionuclide techniques, but such approaches have been usually implemented only in research-oriented laboratories because of technical difficulties. A very practical radionuclide method is here presented which requires only three static acquisitions after the inhalation of a polydisperse radioaerosol produced by a commercial generator. Data processing is also very simple. The diagnostic performance of the method was tested on a study population of 10 healthy subjects and 10 patients with athrophic bronchitis; a higly significance difference between normal and pathological patients was found. Its simple implementation and diagnostic yield recommend this radionuclide method for the routine assessment of mucociliary clearance also in busy clinical-oriented laboratories

  8. Static and dynamic analyses on the MFTF [Mirror Fusion Test Facility]-B Axicell Vacuum Vessel System: Final report

    International Nuclear Information System (INIS)

    Ng, D.S.

    1986-09-01

    The Mirror Fusion Test Facility (MFTF-B) at Lawrence Livermore National Laboratory (LLNL) is a large-scale, tandem-mirror-fusion experiment. MFTF-B comprises many highly interconnected systems, including a magnet array and a vacuum vessel. The vessel, which houses the magnet array, is supported by reinforced concrete piers and steel frames resting on an array of foundations and surrounded by a 7-ft-thick concrete shielding vault. The Pittsburgh-Des Moines (PDM) Corporation, which was awarded the contract to design and construct the vessel, carried out fixed-base static and dynamic analyses of a finite-element model of the axicell vessel and magnet systems, including the simulation of various loading conditions and three postulated earthquake excitations. Meanwhile, LLNL monitored PDM's analyses with modeling studies of its own, and independently evaluated the structural responses of the vessel in order to define design criteria for the interface members and other project equipment. The assumptions underlying the finite-element model and the behavior of the axicell vessel are described in detail in this report, with particular emphasis placed on comparing the LLNL and PDM studies and on analyzing the fixed-base behavior with the soil-structure interaction, which occurs between the vessel and the massive concrete vault wall during a postulated seismic event. The structural members that proved sensitive to the soil effect are also reevaluated

  9. Constitutive equation of butter at static loading

    Directory of Open Access Journals (Sweden)

    Šárka Nedomová

    2008-01-01

    Full Text Available This study focuses on the constitutive modelling of finite deformation in the commercially obtained butter (composition is 83 % of milk fat at the temperature 17–20 °C. The specimens from the butter (height L0=14.6 mm and diameter 20 mm have been compressed between two parallel metal plates at a fixed crosshead speed 20 mm/min using of the testing device TIRA TEST. The force F and the deformation ∆L are measured during compression and both quantities are recorded. The experimental records force F – displacement (deformation were obtained. These records have been transformed into stress–strain dependences and into true stress–true strain. The basic data on the strain behaviour of a butter under low strain rates have been obtained. Experimental results show that the behaviour of butter can be described by a hyperelastic material model. In this model, the quasi–static response is defined by compressible hyperelasticity, whereby the strain energy potential is assumed to be representable by a newly proposed polynomial series with three independent parameters. The material parameters in the constitutive model are determined from compression test. A comparison of predictions based on the proposed constitutive equation with experiments shows that the model is able to describe the strain behaviour of the butter examined.

  10. Intracage ammonia levels in static and individually ventilated cages housing C57BL/6 mice on 4 bedding substrates.

    Science.gov (United States)

    Ferrecchia, Christie E; Jensen, Kelly; Van Andel, Roger

    2014-03-01

    The relationship among ammonia levels, cage-changing frequency, and bedding types is an important and potentially controversial topic in the laboratory animal science community. Some bedding options may not provide sufficient urine absorption and bacterial regulation to minimize ammonia production during the interval between cage changes. High intracage ammonia levels can cause subclinical degeneration and inflammation of nasal passages, rhinitis and olfactory epithelial necrosis in exposed mice. Here we sought to compare the effects of 4 commonly used bedding substrates (1/4-in. irradiated corncob, reclaimed wood pulp, aspen wood chips, and recycled newspaper) on ammonia generation when housing female C57BL/6 mice in static and individually ventilated caging. Intracage ammonia levels were measured daily for 1 wk (static cage experiment) or 2 wk (IVC experiment). The results of this study suggest that the corncob, aspen wood chip, and recycled newspaper beddings that we tested are suitable for once-weekly cage changing for static cages and for changing every 2 wk for IVC. However, ammonia levels were not controlled appropriately in cages containing reclaimed wood pulp bedding, and pathologic changes occurred within 1 wk in the nares of mice housed on this bedding in static cages.

  11. Effects of temperature and strain rate on the tensile behaviors of SIMP steel in static lead bismuth eutectic

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jian, E-mail: jliu12b@imr.ac.cn [Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016 (China); University of Chinese Academy of Sciences, Beijing, 100049 (China); Yan, Wei [Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016 (China); Sha, Wei [School of Planning, Architecture and Civil Engineering, Queen' s University Belfast, Belfast, BT9 5AG (United Kingdom); Wang, Wei; Shan, Yiyin [Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016 (China); Yang, Ke, E-mail: kyang@imr.ac.cn [Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016 (China)

    2016-05-15

    In order to assess the susceptibility of candidate structural materials to liquid metal embrittlement, this work investigated the tensile behaviors of ferritic-martensitic steel in static lead bismuth eutectic (LBE). The tensile tests were carried out in static lead bismuth eutectic under different temperatures and strain rates. Pronounced liquid metal embrittlement phenomenon is observed between 200 °C and 450 °C. Total elongation is reduced greatly due to the liquid metal embrittlement in LBE environment. The range of ductility trough is larger under slow strain rate tensile (SSRT) test. - Highlights: • The tensile behaviors of SIMP steel in LBE are investigated for the first time. • The SIMP is susceptible to LME at different strain rates and temperatures. • The total elongation is reduced greatly. • The ductility trough is wider under SSRT. • The tensile specimens rupture in brittle manner without obvious necking.

  12. Effects of temperature and strain rate on the tensile behaviors of SIMP steel in static lead bismuth eutectic

    International Nuclear Information System (INIS)

    Liu, Jian; Yan, Wei; Sha, Wei; Wang, Wei; Shan, Yiyin; Yang, Ke

    2016-01-01

    In order to assess the susceptibility of candidate structural materials to liquid metal embrittlement, this work investigated the tensile behaviors of ferritic-martensitic steel in static lead bismuth eutectic (LBE). The tensile tests were carried out in static lead bismuth eutectic under different temperatures and strain rates. Pronounced liquid metal embrittlement phenomenon is observed between 200 °C and 450 °C. Total elongation is reduced greatly due to the liquid metal embrittlement in LBE environment. The range of ductility trough is larger under slow strain rate tensile (SSRT) test. - Highlights: • The tensile behaviors of SIMP steel in LBE are investigated for the first time. • The SIMP is susceptible to LME at different strain rates and temperatures. • The total elongation is reduced greatly. • The ductility trough is wider under SSRT. • The tensile specimens rupture in brittle manner without obvious necking.

  13. Influence Of The Gripping Fixture On The Modified Compact Tension Test Results: Evaluation Of The Experiments On Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Holušová Táňa

    2015-12-01

    Full Text Available The modified compact tension test (MCT might become in the future a stable test configuration for the evaluation of fracture-mechanics parameters or also for description of fatigue behavior of composites materials such as concrete. Core drilling is used for sampling of existing structures. These samples have cylindrical shape with the selected thickness to avoid the stress concentration. This contribution focuses on the evaluation of the fracture behavior during static and quasi static tests. Static tests are performed on standard specimen with diameter 150 mm and length 300 mm. The quasi-static tests are performed using two different gripping fixtures. The results for quasi-static tests are represented as L-COD diagrams (i.e. load vs. crack opening displacement measured on the loading axis. The comparison of results and discussion of advantages and disadvantages are introduced.

  14. Novel friction law for the static friction force based on local precursor slipping.

    Science.gov (United States)

    Katano, Yu; Nakano, Ken; Otsuki, Michio; Matsukawa, Hiroshi

    2014-09-10

    The sliding of a solid object on a solid substrate requires a shear force that is larger than the maximum static friction force. It is commonly believed that the maximum static friction force is proportional to the loading force and does not depend on the apparent contact area. The ratio of the maximum static friction force to the loading force is called the static friction coefficient µM, which is considered to be a constant. Here, we conduct experiments demonstrating that the static friction force of a slider on a substrate follows a novel friction law under certain conditions. The magnitude of µM decreases as the loading force increases or as the apparent contact area decreases. This behavior is caused by the slip of local precursors before the onset of bulk sliding and is consistent with recent theory. The results of this study will develop novel methods for static friction control.

  15. Simulations of the Static Friction Due to Adsorbed Molecules

    OpenAIRE

    He, Gang; Robbins, Mark O.

    2001-01-01

    The static friction between crystalline surfaces separated by a molecularly thin layer of adsorbed molecules is calculated using molecular dynamics simulations. These molecules naturally lead to a finite static friction that is consistent with macroscopic friction laws. Crystalline alignment, sliding direction, and the number of adsorbed molecules are not controlled in most experiments and are shown to have little effect on the friction. Temperature, molecular geometry and interaction potenti...

  16. STEM - software test and evaluation methods: fault detection using static analysis techniques

    International Nuclear Information System (INIS)

    Bishop, P.G.; Esp, D.G.

    1988-08-01

    STEM is a software reliability project with the objective of evaluating a number of fault detection and fault estimation methods which can be applied to high integrity software. This Report gives some interim results of applying both manual and computer-based static analysis techniques, in particular SPADE, to an early CERL version of the PODS software containing known faults. The main results of this study are that: The scope for thorough verification is determined by the quality of the design documentation; documentation defects become especially apparent when verification is attempted. For well-defined software, the thoroughness of SPADE-assisted verification for detecting a large class of faults was successfully demonstrated. For imprecisely-defined software (not recommended for high-integrity systems) the use of tools such as SPADE is difficult and inappropriate. Analysis and verification tools are helpful, through their reliability and thoroughness. However, they are designed to assist, not replace, a human in validating software. Manual inspection can still reveal errors (such as errors in specification and errors of transcription of systems constants) which current tools cannot detect. There is a need for tools to automatically detect typographical errors in system constants, for example by reporting outliers to patterns. To obtain the maximum benefit from advanced tools, they should be applied during software development (when verification problems can be detected and corrected) rather than retrospectively. (author)

  17. Static devices with new permanent magnets

    International Nuclear Information System (INIS)

    Chavanne, J.; Laforest, J.; Pauthenet, R.

    1987-01-01

    The high remanence and coercivity of the new permanent magnet materials are of special interest in the static applications. High ordering temperature and are uniaxial anisotropy at the origin of their good permanent magnet properties are obtained in rare earth-transition metal compounds. Binary SmCo/sub 5/ and Sm/sub 2/Co/sub 17/ and ternary Nd/sub 2/Fe/sub 14/B compounds are the basis materials of the best permanent magnets. new concepts of calculations of static devices with these magnets can be applied: the magnetization can be considered as ridig, the density of the surface Amperian current is constant, the relative permeability is approximately 1 and the induction calculations are linear. Examples of hexapoles with Sm-Co and NdFeB magnets are described and the performances are compared. The problems of temperature behavior and corrosion resistance are underlined

  18. Experimental Comparison of Statically and Cyclically Loaded Non-Slender Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo

    rigid form of motion. The Winkler model approach, employing p-y curves to describe the soil-pile interaction, is often employed as the design method for laterally loaded piles. The p-y curve formulation, currently recommended by the American Petroleum Institute and Det Norske Veritas, is based on tests...... on slender piles with length to diameter ratios larger than ten and outer pile diameters less than two meters. Hence, the pile tests that form the basis of the currently recommended p-y curve formulation are conducted with use of piles that exhibits a flexible behaviour, which is in contrast to the piles...... used as foundation for modern offshore wind energy converters. The aim of the present work is to investigate the pile behaviour for non-slender piles by means of small-scale testing. The pile behaviour is investigated and compared for both static and cyclic loading. When conducting small-scale tests...

  19. The whole space three-dimensional magnetotelluric inversion algorithm with static shift correction

    Science.gov (United States)

    Zhang, K.

    2016-12-01

    Base on the previous studies on the static shift correction and 3D inversion algorithms, we improve the NLCG 3D inversion method and propose a new static shift correction method which work in the inversion. The static shift correction method is based on the 3D theory and real data. The static shift can be detected by the quantitative analysis of apparent parameters (apparent resistivity and impedance phase) of MT in high frequency range, and completed correction with inversion. The method is an automatic processing technology of computer with 0 cost, and avoids the additional field work and indoor processing with good results.The 3D inversion algorithm is improved (Zhang et al., 2013) base on the NLCG method of Newman & Alumbaugh (2000) and Rodi & Mackie (2001). For the algorithm, we added the parallel structure, improved the computational efficiency, reduced the memory of computer and added the topographic and marine factors. So the 3D inversion could work in general PC with high efficiency and accuracy. And all the MT data of surface stations, seabed stations and underground stations can be used in the inversion algorithm. The verification and application example of 3D inversion algorithm is shown in Figure 1. From the comparison of figure 1, the inversion model can reflect all the abnormal bodies and terrain clearly regardless of what type of data (impedance/tipper/impedance and tipper). And the resolution of the bodies' boundary can be improved by using tipper data. The algorithm is very effective for terrain inversion. So it is very useful for the study of continental shelf with continuous exploration of land, marine and underground.The three-dimensional electrical model of the ore zone reflects the basic information of stratum, rock and structure. Although it cannot indicate the ore body position directly, the important clues are provided for prospecting work by the delineation of diorite pluton uplift range. The test results show that, the high quality of

  20. Simple and Reliable Method to Estimate the Fingertip Static Coefficient of Friction in Precision Grip.

    Science.gov (United States)

    Barrea, Allan; Bulens, David Cordova; Lefevre, Philippe; Thonnard, Jean-Louis

    2016-01-01

    The static coefficient of friction (µ static ) plays an important role in dexterous object manipulation. Minimal normal force (i.e., grip force) needed to avoid dropping an object is determined by the tangential force at the fingertip-object contact and the frictional properties of the skin-object contact. Although frequently assumed to be constant for all levels of normal force (NF, the force normal to the contact), µ static actually varies nonlinearly with NF and increases at low NF levels. No method is currently available to measure the relationship between µ static and NF easily. Therefore, we propose a new method allowing the simple and reliable measurement of the fingertip µ static at different NF levels, as well as an algorithm for determining µ static from measured forces and torques. Our method is based on active, back-and-forth movements of a subject's finger on the surface of a fixed six-axis force and torque sensor. µ static is computed as the ratio of the tangential to the normal force at slip onset. A negative power law captures the relationship between µ static and NF. Our method allows the continuous estimation of µ static as a function of NF during dexterous manipulation, based on the relationship between µ static and NF measured before manipulation.

  1. FACET Tolerances for Static and Dynamic Misalignments

    Energy Technology Data Exchange (ETDEWEB)

    Federico, Joel

    2012-07-13

    The Facility for AdvancedAccelerator and Experimental Tests (FACET) at the SLAC National Accelerator Laboratory is designed to deliver a beam with a transverse spot size on the order of 10 {micro}m x 10 {micro}m in a new beamline constructed at the two kilometer point of the SLAC linac. Commissioning the beamline requires mitigating alignment errors and their effects, which can be significant and result in spot sizes orders of magnitude larger. Sextupole and quadrupole alignment errors in particular can introduce errors in focusing, steering, and dispersion which can result in spot size growth, beta mismatch, and waist movement. Alignment errors due to static misalignments, mechanical jitter, energy jitter, and other physical processes can be analyzed to determine the level of accuracy and precision that the beamline requires. It is important to recognize these effects and their tolerances in order to deliver a beam as designed.

  2. Robot-Crawler: Statically Balanced Gaits

    Directory of Open Access Journals (Sweden)

    S. Parasuraman

    2012-12-01

    Full Text Available This paper presents a new statically balanced walking technique for a robot-crawler. The gait design and the control of the robot crawler aim to achieve stability while walking. This statically balanced gait has to be designed in a different fashion to a wheeled robot, as there are discrete changes in the support of the robot when its legs are lifted or placed on the ground. The stability of the robot depends on how the legs are positioned relative to the body and also on the sequence and timing with which the legs are lifted and placed. In order to reduce the risk of stability loss while walking, a measure for the robot stability (so-called stability margin is typically used in the gait and motion planning. In this paper different biological behaviours of four-legged animals are studied and mapped on a quad-legrobot-crawler. Experiments were carried out on the forward walking gaits of lizards and horses. Based on these results, the stability margins of different gaits are discussed and compared.

  3. Influence of visual control, conduction, and central integration on static and dynamic balance in healthy older adults.

    Science.gov (United States)

    Perrin, P P; Jeandel, C; Perrin, C A; Béné, M C

    1997-01-01

    Aging is associated with decreased balance abilities, resulting in an increased risk of fall. In order to appreciate the visual, somatosensory, and central signals involved in balance control, sophisticated methods of posturography assessment have been developed, using static and dynamic tests, eventually associated with electromyographic measurements. We applied such methods to a population of healthy older adults in order to appreciate the respective importance of each of these sensorial inputs in aging individuals. Posture control parameters were recorded on a force-measuring platform in 41 healthy young (age 28.5 +/- 5.9 years) and 50 older (age 69.8 +/- 5.9 years) adults, using a static test and two dynamic tests performed by all individuals first with eyes open, then with eyes closed. The distance covered by the center of foot pressure, sway area, and anteroposterior oscillations were significantly higher, with eyes open or closed, in older people than in young subjects. Significant differences were noted in dynamic tests with longer latency responses in the group of old people. Dynamic recordings in a sinusoidal test had a more regular pattern when performed eyes open in both groups and evidenced significantly greater instability in old people. These data suggest that vision remains important in maintaining postural control while conduction and central integration become less efficient with age.

  4. Distinct Nature of Static and Dynamic Magnetic Stripes in Cuprate Superconductors

    Science.gov (United States)

    Jacobsen, H.; Holm, S. L.; Lǎcǎtuşu, M.-E.; Rømer, A. T.; Bertelsen, M.; Boehm, M.; Toft-Petersen, R.; Grivel, J.-C.; Emery, S. B.; Udby, L.; Wells, B. O.; Lefmann, K.

    2018-01-01

    We present detailed neutron scattering studies of the static and dynamic stripes in an optimally doped high-temperature superconductor, La2 CuO4 +y . We observe that the dynamic stripes do not disperse towards the static stripes in the limit of vanishing energy transfer. Therefore, the dynamic stripes observed in neutron scattering experiments are not the Goldstone modes associated with the broken symmetry of the simultaneously observed static stripes, and the signals originate from different domains in the sample. These observations support real-space electronic phase separation in the crystal, where the static stripes in one phase are pinned versions of the dynamic stripes in the other, having slightly different periods. Our results explain earlier observations of unusual dispersions in underdoped La2 -xSrx CuO4 (x =0.07 ) and La2 -xBax CuO4 (x =0.095 ).

  5. Improved quasi-static nodal green's function method

    International Nuclear Information System (INIS)

    Li Junli; Jing Xingqing; Hu Dapu

    1997-01-01

    Improved Quasi-Static Green's Function Method (IQS/NGFM) is presented, as an new kinetic method. To solve the three-dimensional transient problem, improved Quasi-Static Method is adopted to deal with the temporal problem, which will increase the time step as long as possible so as to decrease the number of times of space calculation. The time step of IQS/NGFM can be increased to 5∼10 times longer than that of Full Implicit Differential Method. In spatial calculation, the NGFM is used to get the distribution of shape function, and it's spatial mesh can be nearly 20 times larger than that of Definite Differential Method. So the IQS/NGFM is considered as an efficient kinetic method

  6. Pressure sensor for use in the Loss-of-Fluid-Test (LOFT) reactor

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1979-07-01

    Tests at temperatures up to 800 0 F and pressures up to 2500 psig were conducted at Hanford Engineering Development Laboratory (HEDL) to qualify an instrument for measurement of fuel-rod pressure in the Loss-of-Fluid-Test (LOFT) reactor. Operational characteristics of the selected pressure transducers are summarized for a series of static, quasi-static, and transient tests conducted for a period of about 700 hours

  7. Enhancing Creativity by Test Diversity

    DEFF Research Database (Denmark)

    Probst, Christian; Nielson, Hanne Riis; Nielson, Flemming

    2006-01-01

    Elements of education fall in four major categories—teaching, learning, evaluation, and experimentation. Each of these elements can have differing impact on the overall result of an education process, partly due to the personal experience provided to learners. Obviously, this connection also hold......-understood abstraction technique from computer science, as input data for test generation. This allows describing test data in a concise and compact way, and generating a potentially infinite number of tests as well as a checker to verify solutions....... a quiz. However, since the initial set of questions is static, the number of possible quizzes is static as well. Students will have to take several quizzes before having seen all questions and this is often experi-enced as being very unsatisfactory. We suggest using finite automata, a well...

  8. On the equivalent static loads approach for dynamic response structural optimization

    DEFF Research Database (Denmark)

    Stolpe, Mathias

    2014-01-01

    The equivalent static loads algorithm is an increasingly popular approach to solve dynamic response structural optimization problems. The algorithm is based on solving a sequence of related static response structural optimization problems with the same objective and constraint functions...... as the original problem. The optimization theoretical foundation of the algorithm is mainly developed in Park and Kang (J Optim Theory Appl 118(1):191–200, 2003). In that article it is shown, for a certain class of problems, that if the equivalent static loads algorithm terminates then the KKT conditions...

  9. On perfect fluids and black holes in static equilibrium

    International Nuclear Information System (INIS)

    Carrasco, Alberto; Mars, Marc; Simon, Walter

    2007-01-01

    Proofs of spherical symmetry of static black holes and of spherical symmetry of static perfect fluids normally require, a priori, 'black holes only' or 'fluid only'. In a recent paper Shiromizu, Yamada and Yoshino admit a priori (and exclude) coexistence of fluids and holes. This work assumes connectedness of the fluid region and the same assumptions on the equation of state as earlier papers on the 'fluid only' case, and requires in addition an upper bound for the fluid mass in terms of the black holes masses. We discuss this paper. As a new result we show that there cannot exist static fluid shells (i.e. fluid regions of the topology of an annulus) even if one a priori admits, inside and outside the shell, any arrangement of black holes or additional matter which satisfies the energy condition

  10. Static dipole polarizabilities of Scn (n ≤ 15) clusters

    International Nuclear Information System (INIS)

    Xi-Bo, Li; Jiang-Shan, Luo; Wei-Dong, Wu; Yong-Jian, Tang; Hong-Yan, Wang; Yun-Dong, Guo

    2009-01-01

    The static dipole polarizabilities of scandium clusters with up to 15 atoms are determined by using the numerically finite field method in the framework of density functional theory. The electronic effects on the polarizabilities are investigated for the scandium clusters. We examine a large highest occupied molecular orbital — the lowest occupied molecular orbital (HOMO–LUMO) gap of a scandium cluster usually corresponds to a large dipole moment. The static polarizability per atom decreases slowly and exhibits local minimum with increasing cluster size. The polarizability anisotropy and the ratio of mean static polarizability to the HOMO–LUMO gap can also reflect the cluster stability. The polarizability of the scandium cluster is partially related to the HOMO–LUMO gap and is also dependent on geometrical characteristics. A strong correlation between the polarizability and ionization energy is observed. (atomic and molecular physics)

  11. Damping Inter-area Oscillations using Static Synchronous Series Compensator (SSSC)

    DEFF Research Database (Denmark)

    Su, Chi; Chen, Zhe

    2011-01-01

    Static synchronous series compensator (SSSC) has the ability to emulate a reactance in series with the connected transmission line. When fed with some supplementary signals from the connected system, SSSC is able to participate in the power system inter-area oscillation damping by changing...... the compensated reactance. This paper analyses the influence of SSSC on power system small signal stability. A SSSC damping controller scheme is presented and discussed. In DIgSILENT PowerFactory software, modal analysis and time-domain simulation are conducted in a single-machine infinite bus system model...... and a four-machine two-area test system model to verify and improve the damping controller scheme....

  12. Static Equilibrium Configurations of Charged Metallic Bodies

    African Journals Online (AJOL)

    Key words: Static equilibrium, charged metallic body, potential energy, projected gradient method. ... television, radio, internet, microwave ovens, mobile telephones, satellite communication systems, radar systems, electrical motors, electrical.

  13. Supporting secure programming in web applications through interactive static analysis

    Science.gov (United States)

    Zhu, Jun; Xie, Jing; Lipford, Heather Richter; Chu, Bill

    2013-01-01

    Many security incidents are caused by software developers’ failure to adhere to secure programming practices. Static analysis tools have been used to detect software vulnerabilities. However, their wide usage by developers is limited by the special training required to write rules customized to application-specific logic. Our approach is interactive static analysis, to integrate static analysis into Integrated Development Environment (IDE) and provide in-situ secure programming support to help developers prevent vulnerabilities during code construction. No additional training is required nor are there any assumptions on ways programs are built. Our work is motivated in part by the observation that many vulnerabilities are introduced due to failure to practice secure programming by knowledgeable developers. We implemented a prototype interactive static analysis tool as a plug-in for Java in Eclipse. Our technical evaluation of our prototype detected multiple zero-day vulnerabilities in a large open source project. Our evaluations also suggest that false positives may be limited to a very small class of use cases. PMID:25685513

  14. Supporting secure programming in web applications through interactive static analysis

    Directory of Open Access Journals (Sweden)

    Jun Zhu

    2014-07-01

    Full Text Available Many security incidents are caused by software developers’ failure to adhere to secure programming practices. Static analysis tools have been used to detect software vulnerabilities. However, their wide usage by developers is limited by the special training required to write rules customized to application-specific logic. Our approach is interactive static analysis, to integrate static analysis into Integrated Development Environment (IDE and provide in-situ secure programming support to help developers prevent vulnerabilities during code construction. No additional training is required nor are there any assumptions on ways programs are built. Our work is motivated in part by the observation that many vulnerabilities are introduced due to failure to practice secure programming by knowledgeable developers. We implemented a prototype interactive static analysis tool as a plug-in for Java in Eclipse. Our technical evaluation of our prototype detected multiple zero-day vulnerabilities in a large open source project. Our evaluations also suggest that false positives may be limited to a very small class of use cases.

  15. Interaction between hopping and static spins in a discrete network

    Energy Technology Data Exchange (ETDEWEB)

    Ciccarello, Francesco, E-mail: francesco.ciccarello@sns.it [CNISM and Dipartimento di Fisica, Universita' degli Studi di Palermo, Viale delle Scienze, Edificio 18, I-90128 Palermo (Italy); NEST, Scuola Normale Superiore and Istituto Nanoscienze-CNR, Piazza dei Cavalieri 7, I-56126 Pisa (Italy)

    2011-06-27

    We consider a process where a spin hops across a discrete network and at certain sites couples to static spins. While this setting is implementable in various scenarios (e.g. quantum dots or coupled cavities) the physics of such processes is still basically unknown. Here, we take a first step along this line by scrutinizing a two-site and a three-site lattices, each with two static spins. Despite a generally complex dynamics occurs, we show a regime such that the spin dynamics is described by an effective three-spin chain. Tasks such as entanglement generation and quantum state transfer can be achieved accordingly. -- Highlights: → We study mobile spins hopping in a discrete network and coupled to static spins. → This setting can be implemented in various scenarios. → We address a two-site and a three-site lattice, each with two static spins. → We show a regime where the setup can be described by an effective three-spin chain. → Accordingly, it is prone to be exploited for some QIP applications.

  16. A scanning bi-static SODAR

    Energy Technology Data Exchange (ETDEWEB)

    Behrens, P; Bradley, S [Physics Department, Auckland University, 38 Princes Street, Auckland (New Zealand); Hunerbein, S von [Acoustics Department, Newton Building, University of Salford, Greater Manchester M5 4WT (United Kingdom)

    2008-05-01

    Field results are given from a bi-static SODAR which uses a single central vertical transmission and three distributed microphone array receivers. Fourier transform delay methods are applied to data sampled from each microphone to retrospectively scan in angle and follow the transmitted pulse. Advantages of sampling a narrow atmospheric column, rather than distributed volumes are discussed.

  17. A scanning bi-static SODAR

    International Nuclear Information System (INIS)

    Behrens, P; Bradley, S; Hunerbein, S von

    2008-01-01

    Field results are given from a bi-static SODAR which uses a single central vertical transmission and three distributed microphone array receivers. Fourier transform delay methods are applied to data sampled from each microphone to retrospectively scan in angle and follow the transmitted pulse. Advantages of sampling a narrow atmospheric column, rather than distributed volumes are discussed

  18. The assessment of static balance in children with hearing, visual and intellectual disabilities

    OpenAIRE

    Aija Klavina; Anna Zusa-Rodke; Zinta Galeja

    2017-01-01

    Background: Balance is a fundamental part of many movement tasks a child performs. Maintaining upright posture is a complex process involving multiple body parts and functional systems. Objective: This study aimed to explore the mean amplitude and velocity of the center of pressure (COP) displacements during static balance tests in children with and without disabilities. Methods: Participants were 34 children (age 8.5 to 10.8 years) including 6 typically developed children, 8 children with he...

  19. From Static to Interactive: Transforming Data Visualization to Improve Transparency.

    Directory of Open Access Journals (Sweden)

    Tracey L Weissgerber

    2016-06-01

    Full Text Available Data presentation for scientific publications in small sample size studies has not changed substantially in decades. It relies on static figures and tables that may not provide sufficient information for critical evaluation, particularly of the results from small sample size studies. Interactive graphics have the potential to transform scientific publications from static reports of experiments into interactive datasets. We designed an interactive line graph that demonstrates how dynamic alternatives to static graphics for small sample size studies allow for additional exploration of empirical datasets. This simple, free, web-based tool (http://statistika.mfub.bg.ac.rs/interactive-graph/ demonstrates the overall concept and may promote widespread use of interactive graphics.

  20. Impact of element-level static condensation on iterative solver performance

    KAUST Repository

    Pardo, D.

    2015-10-02

    This paper provides theoretical estimates that quantify and clarify the savings associated to the use of element-level static condensation as a first step of an iterative solver. These estimates are verified numerically. The numerical evidence shows that static condensation at the element level is beneficial for higher-order methods. For lower-order methods or when the number of iterations required for convergence is low, the setup cost of the elimination as well as its implementation may offset the benefits obtained during the iteration process. However, as the iteration count (e.g., above 50) or the polynomial order (e.g., above cubics) grows, the benefits of element-level static condensation are significant.

  1. A Developmental Study of Static Postural Control and Superimposed Arm Movements in Normal and Slowly Developing Children.

    Science.gov (United States)

    Fisher, Janet M.

    Selected electromyographic parameters underlying static postural control in 4, 6, and 8 year old normally and slowly developing children during performance of selected arm movements were studied. Developmental delays in balance control were assessed by the Cashin Test of Motor Development (1974) and/or the Williams Gross Motor Coordination Test…

  2. Quasi-static elastography comparison of hyaline cartilage structures

    Science.gov (United States)

    McCredie, A. J.; Stride, E.; Saffari, N.

    2009-11-01

    Joint cartilage, a load bearing structure in mammals, has only limited ability for regeneration after damage. For tissue engineers to design functional constructs, better understanding of the properties of healthy tissue is required. Joint cartilage is a specialised structure of hyaline cartilage; a poroviscoelastic solid containing fibril matrix reinforcements. Healthy joint cartilage is layered, which is thought to be important for correct tissue function. However, the behaviour of each layer during loading is poorly understood. Ultrasound elastography provides access to depth-dependent information in real-time for a sample during loading. A 15 MHz focussed transducer provided details from scatterers within a small fixed region in each sample. Quasi-static loading was applied to cartilage samples while ultrasonic signals before and during compressions were recorded. Ultrasonic signals were processed to provide time-shift profiles using a sum-squared difference method and cross-correlation. Two structures of hyaline cartilage have been tested ultrasonically and mechanically to determine method suitability for monitoring internal deformation differences under load and the effect of the layers on the global mechanical material behaviour. Results show differences in both the global mechanical properties and the ultrasonically tested strain distributions between the two structures tested. It was concluded that these differences are caused primarily by the fibril orientations.

  3. Temperature-controlled continuous production of all-trans retinoic acid-loaded solid lipid nanoparticles using static mixers

    Science.gov (United States)

    Shao, Wenyao; Yan, Mengwen; Chen, Tingting; Chen, Yuqing; Xiao, Zongyuan

    2017-04-01

    This work aims to develop a temperature-controlled continuous solvent emulsification-diffusion process to synthesize all-trans retinoic acid (ATRA)-loaded solid lipid nanoparticles (SLNs) using static mixers. ATRA-loaded SLNs of around 200 nm were obtained when the flow rates of the organic and aqueous phases were 50 ml min-1 and 500 ml min-1, respectively. It was found that the lipid concentration played a dominant role in the size of the obtained SLNs, and higher drug concentration resulted in relatively low entrapment efficiency. The encapsulation of ATRA in the SLNs was effective in improving its stability according to the photo-degradation test. The in vitro release of SLN was slow without an initial burst. This study demonstrates that the solvent emulsification-diffusion technique with static mixing is an effective method of producing SLNs, and could easily be scaled up for industrial applications. Highlights Higher lipid concentration leads to larger SLNs. SLN transformation occurs due to Ostwald ripening. The ATRA-loaded SLNs around 200 nm were successfully produced with static mixers. ATRA-loaded SLNs show better stability towards sunlight. ATRA in SLNs exhibited a relatively slow release rate without a significant initial burst.

  4. Calculation of equivalent static loads and its application

    International Nuclear Information System (INIS)

    Choi, Woo-Seok; Park, K.B.; Park, G.J.

    2005-01-01

    All the forces in the real world act dynamically on structures. Since dynamic loads are extremely difficult to handle in analysis and design, static loads are usually utilized with dynamic factors. Generally, the dynamic factors are determined from design codes or experience. Therefore, static loads may not give accurate solutions in analysis and design and structural engineers often come up with unreliable solutions. Two different methods are proposed for the transformation of dynamic loads into equivalent static loads (ESLs). One is an analytical method for exact ESLs and the other is an approximation method. The exact ESLs are calculated to generate identical response fields such as displacement and stress with those from dynamic loads at a certain time. Some approximation methods are proposed in engineering applications, which generate similar response fields from dynamic loads. They are divided into the displacement-based approach and the stress-based approach. The process is derived and evaluated mathematically. Standard examples are selected and solved by the proposed method and error analyses are conducted. Applications of the method to structural optimization are discussed

  5. Precipitation-Static-Reduction Research

    Science.gov (United States)

    1943-03-31

    if» 85 z \\ PRECIPITATION-STATIC-REDUCTION RESEARCH study of the effects of flame length , flame spacing, and burner spacing on B shows that there...unod: Flame length *. The visual length of the flame from the burner tip to the flame tip when examined in a darkened room against a black background...Postlve and Negative Flames The use of the second flame-conduction coefficient, B, facilitates considerably the study of the effect of flame length , spacing

  6. The Static Quantum Multiverse

    OpenAIRE

    Nomura, Yasunori

    2012-01-01

    We consider the multiverse in the intrinsically quantum mechanical framework recently proposed in Refs. [1,2]. By requiring that the principles of quantum mechanics are universally valid and that physical predictions do not depend on the reference frame one chooses to describe the multiverse, we find that the multiverse state must be static---in particular, the multiverse does not have a beginning or end. We argue that, despite its naive appearance, this does not contradict observation, inclu...

  7. Acute Effects of Static vs. Ballistic Stretching on Strength and Muscular Fatigue Between Ballet Dancers and Resistance-Trained Women.

    Science.gov (United States)

    Lima, Camila D; Brown, Lee E; Wong, Megan A; Leyva, Whitney D; Pinto, Ronei S; Cadore, Eduardo L; Ruas, Cassio V

    2016-11-01

    Lima, CD, Brown, LE, Wong, MA, Leyva, WD, Pinto, RS, Cadore, EL, and Ruas, CV. Acute effects of static vs. ballistic stretching on strength and muscular fatigue between ballet dancers and resistance-trained women. J Strength Cond Res 30(11): 3220-3227, 2016-Stretching is used to increase joint range of motion, but the acute effects can decrease muscle strength. However, this may depend on the population or mode of stretching. The purpose of this study was to compare the acute effects of static vs. ballistic stretching on strength and muscular fatigue between ballet dancers and resistance-trained women. Fifteen resistance-trained women (age 23.8 ± 1.80 years, mass 67.47 ± 7.77 kg, height 168.30 ± 5.53 cm) and 12 ballet dancers (age 22.8 ± 3.04 years, mass 58.67 ± 5.65 kg, height 168.00 ± 7.69 cm) performed 5 days of testing. The first day was control (no stretching), whereas the other 4 days were static or ballistic stretching in a counterbalanced order. Range of motion, strength, and fatigue tests were also performed. Both groups demonstrated a significant decrease in hamstrings strength after static (102.71 ± 2.67 N·m) and ballistic stretching (99.49 ± 2.61 N·m) compared with control (113.059 ± 3.25 N·m), with no changes in quadriceps strength. For fatigue, only ballet dancers demonstrated a decrease from control (71.79 ± 4.88%) to ballistic (65.65 ± 8.19%), but no difference with static (65.01 ± 12.29%). These findings suggest that stretching decreases hamstrings strength similarly in ballet dancers and resistance-trained women, with no differences between modes of stretching. However, ballistic stretching only decreased muscular fatigue in ballet dancers, but not in resistance-trained women. Therefore, no stretching should be performed before strength performance. However, ballistic stretching may decrease acute muscular fatigue in ballet dancers.

  8. Composite slab behavior and strength analysis under static and dynamic loads

    Directory of Open Access Journals (Sweden)

    Florin Radu HARIGA

    2012-07-01

    Full Text Available Steel-framed buildings are typically constructed using steel-deck-reinforced concrete floor slabs. The in-plane (or diaphragm strength and stiffness of the floor system are frequently utilized in the lateral load-resisting system design. This paper presents the results of an experimental research program in which four full size composite diaphragms were vertically loaded to the limit state, under static or dynamic loads. Two test specimens were provided with longitudinal steel-deck ribs, and the other two specimens with cross steel-deck ribs. Typical composite diaphragm limit states are described, and the controlling limit state for each of the full size tests is indicated. The interaction effects between the reinforced concrete slab and the steel girder on the composite slab strength and stiffness were mainly studied.

  9. Experimental Comparison of Non-Slender Piles under Static Loading and under Cyclic Loading in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo

    2012-01-01

    An experimental evaluation of the pile behavior of non-slender piles exposed to static and cyclic lateral loading is presented. The tests were conducted in a pressure tank at Aalborg University. This enabled the possibility of applying an overburden pressure to the soil. When conducting small......-scale tests at 1-g the determination of the friction angle and the Young’s modulus of elasticity of the soil are difficult and further these soil parameters varies greatly with depth. These uncertainties were avoided by application of an overburden pressure....

  10. A study of microstructure, quasi-static response, fatigue, deformation and fracture behavior of high strength alloy steels

    Science.gov (United States)

    Kannan, Manigandan

    The history of steel dates back to the 17th century and has been instrumental in the betterment of every aspect of our lives ever since, from the pin that holds the paper together to the Automobile that takes us to our destination steel touches everyone every day. Path breaking improvements in manufacturing techniques, access to advanced machinery and understanding of factors like heat treatment, corrosion resistance have aided in the advancement in the properties of steel in the last few years. In this dissertation document, the results of a study aimed at the influence of alloy chemistry, processing and influence of the quasi static and fatigue behavior of seven alloy steels is discussed. The microstructure of the as-received steel was examined and characterized for the nature and morphology of the grains and the presence of other intrinsic features in the microstructure. The tensile, cyclic fatigue and bending fatigue tests were done on a fully automated closed-loop servo-hydraulic test machine at room temperature. The failed samples of high strength steels were examined in a scanning electron microscope for understanding the fracture behavior, especially the nature of loading be it quasi static, cyclic fatigue or bending fatigue . The quasi static and cyclic fatigue fracture behavior of the steels examined coupled with various factors contributing to failure are briefly discussed in light of the conjoint and mutually interactive influences of intrinsic microstructural effects, nature of loading, and stress (load)-deformation-microstructural interactions.

  11. Accuracy of Replicating Static Torque and its Effect on Shooting Accuracy in Young Basketball Players

    Directory of Open Access Journals (Sweden)

    Struzik Artur

    2014-12-01

    Full Text Available Purpose. Accurate shooting in basketball is a prerequisite for success. Coordination ability, one of the abilities that determine the repeatability of accurate shooting, is based on kinesthetic differentiation. The aim of the study was to evaluate the strength component of kinesthetic differentiation ability and determine its relationship with shooting accuracy. Methods. Peak muscle torque of the elbow extensors under static conditions was measured in 12 young basketball players. Participants then reproduced the same movement at a perceived magnitude of 25%, 50%, and 75% of static peak torque, with error scores calculated as a measure of kinesthetic differentiation. The results were compared with players’ field goal percentages calculated during game play in a regional championship. Results. No statistically significant relationships were found between the level of kinesthetic differentiation ability and field goal percentage. Additionally, no upper limb asymmetry was found in the sample. Conclusions. The relatively high levels of elbow static peak torque suggest the importance of upper limb strength in contemporary basketball. The lack of a statistically significant difference between the right and left limbs decreases the risk of suffering injury. It is likely that choosing other suitable tests would demonstrate the relationships between field goal percentage and kinesthetic differentiation ability.

  12. EFFECTS OF CYCLIC STATIC STRETCH ON FATIGUE RECOVERY OF TRICEPS SURAE IN FEMALE BASKETBALL PLAYERS

    Directory of Open Access Journals (Sweden)

    Mehri Ghasemia

    2013-04-01

    Full Text Available Static stretch is a safe and feasible method which usually is used before exercise to avoid muscle injury and to improve muscle performance. The purpose of this study was to determine the effects of cyclic static stretch (CSS on fatigue recovery of triceps surae (TS in female basketball players.Nine athlete volunteers between 20 and 30 years participated in this study containing two sessions. After warm-up a pressure cuff was fastened above the knee joint and its pressure was increased to 140 mmHg. The subjects were asked to perform one maximum voluntary contraction (MVC followed by a fatigue test including maximum isometric fatiguing contraction of TS. These steps were similar in both sessions. Then, a two-minute rest was included in the first session while 4 static stretches were performed to TS in the second session. After interventions, one MVC was done and the pressure cuff was released. During these steps, peak torque (PT and electromyography (EMG were recorded. The amount of lower leg pain was determined by the visual analogue scale (VAS. The value of PT increased significantly after CSS but its increase was not significant after rest. It seems that the effects of rest and CSS on the EMG parameters, PT and pain are similar.

  13. Physiological Response to Static Muscle Contractions in Standing and Supine Positions

    DEFF Research Database (Denmark)

    Pedersen, Jens Meldgaard; Andersen, T. Bull

    2013-01-01

    The purpose of this study was to investigate the physiological responses to static muscle contractions in the standing position and the supine position. Eight subjects performed static contractions of the ankle extensors in both positions. Blood pressure (SBP and DBP), heart rate (HR...

  14. Static Analysis of Steel Fiber Concrete Beam With Heterosis Finite Elements

    Directory of Open Access Journals (Sweden)

    James H. Haido

    2014-08-01

    Full Text Available Steel fiber is considered as the most commonly used constructional fibers in concrete structures. The formulation of new nonlinearities to predict the static performance of steel fiber concrete composite structures is considered essential. Present study is devoted to investigate the efficiency of utilizing heterosis finite elements analysis in static analysis of steel fibrous beams. New and simple material nonlinearities are proposed and used in the formulation of these elements. A computer program coded in FORTRAN was developed to perform current finite element static analysis with considering four cases of elements stiffness matrix determination. The results are compared with the experimental data available in literature in terms of central deflections, strains, and failure form, good agreement was found. Suitable outcomes have been observed in present static analysis with using of tangential stiffness matrix and stiffness matrix in second iteration of the load increment.

  15. Static Extraction of Object-Oriented Runtime Architectures

    National Research Council Canada - National Science Library

    Abi-Antoun, Marwan; Aldrich, Jonathan

    2008-01-01

    .... But it is hard to statically extract runtime object graphs that provide architectural abstraction from an arbitrary program written in a general purpose language that follows common design idioms...

  16. On static and radiative space-times

    International Nuclear Information System (INIS)

    Friedrich, H.

    1988-01-01

    The conformal constraint equations on space-like hypersurfaces are discussed near points which represent either time-like or spatial infinity for an asymptotically flat solution of Einstein's vacuum field equations. In the case of time-like infinity a certain 'radiativity condition' is derived which must be satisfied by the data at that point. The case of space-like infinity is analysed in detail for static space-times with non-vanishing mass. It is shown that the conformal structure implied here on a slice of constant Killing time, which extends analytically through infinity, satisfies at spatial infinity the radiativity condition. Thus to any static solution exists a certain 'radiative solution' which has a smooth structure at past null infinity and is regular at past time-like infinity. A characterization of these solutions by their 'free data' is given and non-symmetry properties are discussed. (orig.)

  17. Differences in dynamic and static functional connectivity between young and elderly healthy adults

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Eun; Jung, Seung Chai; Ryu, Kyeoung Hwa; Oh, Joo Young; Kim, Ho Sung; Choi, Choong-Gon; Kim, Sang Joon; Shim, Woo Hyun [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Songpa-Gu, Seoul (Korea, Republic of)

    2017-08-15

    Brain connectivity is highly dynamic, but functional connectivity (FC) studies using resting-state functional magnetic resonance imaging (rs-fMRI) assume it to be static. This study assessed differences in dynamic FC between young healthy adults (YH) and elderly healthy adults (EH) compared to static FC. Using rs-fMRI data from 12 YH and 31 EH, FC was assessed in six functional regions (subcortical, auditory [AUD], sensorimotor [SM], visuospatial [VS], cognitive control [CC], and default mode network [DMN]). Static FC was calculated as Fisher's z-transformed correlation coefficient. The sliding time window correlation (window size 30 s, step size 3 s) was applied for dynamic FC, and the standard deviation across sliding windows was calculated. Differences in static and dynamic FC between EH and YH were calculated and compared by region. EH showed decreased static FC in the subcortical, CC, and DMN regions (FDR corrected p = 0.0013; 74 regions), with no regions showing static FC higher than that in YH. EH showed increased dynamic FC in the subcortical, CC, and DMN regions, whereas decreased dynamic FC in CC and DMN regions (p < 0.01). However, the regions showing differences between EH and YH did not overlap between static and dynamic FC. Dynamic FC exhibited differences from static FC in EH and YH, mainly in regions involved in cognitive control and the DMN. Altered dynamic FC demonstrated both qualitatively and quantitatively distinct patterns of transient brain activity and needs to be studied as an imaging biomarker in the aging process. (orig.)

  18. Human body capacitance: static or dynamic concept? [ESD

    DEFF Research Database (Denmark)

    Jonassen, Niels M

    1998-01-01

    A standing human body insulated from ground by footwear and/or floor covering is in principle an insulated conductor and has, as such, a capacitance, i.e. the ability to store a charge and possibly discharge the stored energy in a spark discharge. In the human body, the human body capacitance (HBC...... when a substantial part of the flux extends itself through badly defined stray fields. Since the concept of human body capacitance is normally used in a static (electric) context, it is suggested that the HBC be determined by a static method. No theoretical explanation of the observed differences...

  19. On perfect fluids and black holes in static equilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Carrasco, Alberto; Mars, Marc; Simon, Walter [Facultad de Ciencias, Universidad de Salamanca, Plaza de la Merced s/n, 37008 Salamanca (Spain)

    2007-05-15

    Proofs of spherical symmetry of static black holes and of spherical symmetry of static perfect fluids normally require, a priori, 'black holes only' or 'fluid only'. In a recent paper Shiromizu, Yamada and Yoshino admit a priori (and exclude) coexistence of fluids and holes. This work assumes connectedness of the fluid region and the same assumptions on the equation of state as earlier papers on the 'fluid only' case, and requires in addition an upper bound for the fluid mass in terms of the black holes masses. We discuss this paper. As a new result we show that there cannot exist static fluid shells (i.e. fluid regions of the topology of an annulus) even if one a priori admits, inside and outside the shell, any arrangement of black holes or additional matter which satisfies the energy condition.

  20. Static potentials from an extended gauge symmetry

    International Nuclear Information System (INIS)

    Doria, R.M.; Helayel Neto, J.A.

    1985-01-01

    Static potentials derived from the inclusion of more than one vector field in a single simple group are calculated. A confinement mechanism including colourful unphysical particle is discussed. (Author) [pt