WorldWideScience

Sample records for stark effects diagnostics

  1. Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited)

    Energy Technology Data Exchange (ETDEWEB)

    Pablant, N. A. [University of California-San Diego, La Jolla, California 92093 (United States); Burrell, K. H.; Groebner, R. J.; Kaplan, D. H. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Holcomb, C. T. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2010-10-15

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D{sub {alpha}} emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B{sub {theta}}/B{sub T} and |B| over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0x10{sup 19} m{sup -3}, and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

  2. Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited).

    Science.gov (United States)

    Pablant, N A; Burrell, K H; Groebner, R J; Holcomb, C T; Kaplan, D H

    2010-10-01

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D(α) emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B(θ)/B(T) and ∣B∣ over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0×10(19) m(-3), and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

  3. Atomic Models for Motional Stark Effects Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Gu, M F; Holcomb, C; Jayakuma, J; Allen, S; Pablant, N A; Burrell, K

    2007-07-26

    We present detailed atomic physics models for motional Stark effects (MSE) diagnostic on magnetic fusion devices. Excitation and ionization cross sections of the hydrogen or deuterium beam traveling in a magnetic field in collisions with electrons, ions, and neutral gas are calculated in the first Born approximation. The density matrices and polarization states of individual Stark-Zeeman components of the Balmer {alpha} line are obtained for both beam into plasma and beam into gas models. A detailed comparison of the model calculations and the MSE polarimetry and spectral intensity measurements obtained at the DIII-D tokamak is carried out. Although our beam into gas models provide a qualitative explanation for the larger {pi}/{sigma} intensity ratios and represent significant improvements over the statistical population models, empirical adjustment factors ranging from 1.0-2.0 must still be applied to individual line intensities to bring the calculations into full agreement with the observations. Nevertheless, we demonstrate that beam into gas measurements can be used successfully as calibration procedures for measuring the magnetic pitch angle through {pi}/{sigma} intensity ratios. The analyses of the filter-scan polarization spectra from the DIII-D MSE polarimetry system indicate unknown channel and time dependent light contaminations in the beam into gas measurements. Such contaminations may be the main reason for the failure of beam into gas calibration on MSE polarimetry systems.

  4. The motional stark effect with laser-induced fluorescence diagnostic

    Science.gov (United States)

    Foley, E. L.; Levinton, F. M.

    2010-05-01

    The motional Stark effect (MSE) diagnostic is the worldwide standard technique for internal magnetic field pitch angle measurements in magnetized plasmas. Traditionally, it is based on using polarimetry to measure the polarization direction of light emitted from a hydrogenic species in a neutral beam. As the beam passes through the magnetized plasma at a high velocity, in its rest frame it perceives a Lorentz electric field. This field causes the H-alpha emission to be split and polarized. A new technique under development adds laser-induced fluorescence (LIF) to a diagnostic neutral beam (DNB) for an MSE measurement that will enable radially resolved magnetic field magnitude as well as pitch angle measurements in even low-field (experiments. An MSE-LIF system will be installed on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory. It will enable reconstructions of the plasma pressure, q-profile and current as well as, in conjunction with the existing MSE system, measurements of radial electric fields.

  5. Magnetic field pitch angle diagnostic using the motional Stark effect (invited)

    International Nuclear Information System (INIS)

    Levinton, F.M.; Gammel, G.M.; Kaita, R.; Kugel, H.W.; Roberts, D.W.

    1990-01-01

    The Stark effect has been employed in a novel technique for obtaining the pitch angle profile and q(r) using polarimetry measurements of the Doppler shifted H α emission from a hydrogen diagnostic neutral beam. As a neutral beam propagates through a plasma, collisions of the beam particles with the background ions and electrons will excite beam atoms, leading to emission of radiation. The motional Stark effect, which arises from the electric field induced in the atom's rest frame due to the beam motion across the magnetic field (E=V beam xB), causes a wavelength splitting of several angstroms and polarization of the emitted radiation. The Δm=±1 transitions, or σ components, from the beam fluorescence are linearly polarized parallel to the direction of the local magnetic field when viewed transverse to the fields. Since the hydrogen beam provides good spatial localization and penetration, the pitch angle can be obtained anywhere in the plasma. A photoelastic modulator (PEM) is used to modulate the linearly polarized light. Depending on the orientation of the PEM, it can measure the sine or cosine of the angle of polarization. Two PEM's are used to measure both components simultaneously. Results of q(r) for both Ohmic and NBI heated discharges have been obtained in the Princeton Beta Experiment (PBX-M) tokamak, with an uncertainty of ∼6% for q(0)

  6. Design of a New Optical System for Alcator C-Mod Motional Stark Effect Diagnostic

    International Nuclear Information System (INIS)

    Ko, Jinseok; Scott, Steve; Bitter, Manfred; Lerner, Scott

    2009-01-01

    The motional Stark effect (MSE) diagnostic on Alcator C-Mod uses an in-vessel optical system (five lenses and three mirrors) to relay polarized light to an external polarimeter because port access limitations on Alcator C-Mod preclude a direct view of the diagnostic beam. The system experiences unacceptable, spurious drifts of order several degrees in measured pitch angle over the course of a run day. Recent experiments illuminated the MSE diagnostic with polarized light of fixed orientation as heat was applied to various optical elements. A large change in measured angle was observed as two particular lenses were heated, indicating that thermal-stress-induced birefringence is a likely cause of the spurious variability. Several new optical designs have been evaluated to eliminate the affected in-vessel lenses and to replace the focusing they provide with curved mirrors; however, ray tracing calculations imply that this method is not feasible. A new approach is under consideration that utilizes in situ calibrations with in-vessel reference polarized light sources. 2008 American Institute of Physics.

  7. Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Foley, E. L.; Levinton, F. M. [Nova Photonics, Inc., Princeton, New Jersey 08540 (United States)

    2013-04-15

    The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

  8. Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

    Science.gov (United States)

    Foley, E. L.; Levinton, F. M.

    2013-04-01

    The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

  9. Imaging motional Stark effect measurements at ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Ford, O. P.; Burckhart, A.; McDermott, R.; Pütterich, T.; Wolf, R. C. [Max-Planck Institut für Plasmaphysik, Greifswald/Garching (Germany)

    2016-11-15

    This paper presents an overview of results from the Imaging Motional Stark Effect (IMSE) diagnostic obtained during its first measurement campaign at ASDEX Upgrade since installation as a permanent diagnostic. A brief overview of the IMSE technique is given, followed by measurements of a standard H-mode discharge, which are compared to equilibrium reconstructions showing good agreement where expected. The development of special discharges for the calibration of pitch angle is reported and safety factor profile changes during sawteeth crashes are shown, which can be resolved to a few percent due to the high sensitivity at good time resolution of the new IMSE system.

  10. Stark--Zeeman effect of metastable hydrogen molecules

    International Nuclear Information System (INIS)

    Kagann, R.H.

    1975-01-01

    The Stark effect of the N = 1 rotational level of orthohydrogen and the N = 2 rotational level of parahydrogen in the metastable c 3 PI/sub u/ electronic state has been measured using the molecular beam magnetic resonance method. The Stark effect of the metastable state is 10,000 times larger than that of the ground electronic state. The Stark effect of parahydrogen was found to be weakly dependent on static magnetic field strength, whereas the Stark effect of orthohydrogen was found to be more strongly dependent on the magnetic field strength. The Stark effect of orthohydrogen has been calculated using second-order perturbation theory with a pure Stark effect perturbation. The magnetic field dependence of the Stark effect was calculated using third-order perturbation theory with a mixed Stark--Zeeman effect double perturbation. A comparison of the experimental and theoretical values of α/sub perpendicular/ provides information on the electronic transition moment connecting the c 3 PI/sub u/ state to the a 3 Σ + /sub g/ state. The transition moment is needed to calculate the radiative lifetimes of the various vibrational levels of the c 3 PI/sub u/ state. The transition moment also enters the calculation of the quenching of this metastable state by an external electric field. There is a disagreement between theoretical predictions and the results of an experiment on the electric field quenching of the metastables. A test of the electronic transition moment may help shed light on this question. The experimental determination of the values of the transition moments allows one to test theory by comparing these values to those obtained by calculations employing ab initio wavefunctions

  11. Valley-selective optical Stark effect probed by Kerr rotation

    Science.gov (United States)

    LaMountain, Trevor; Bergeron, Hadallia; Balla, Itamar; Stanev, Teodor K.; Hersam, Mark C.; Stern, Nathaniel P.

    2018-01-01

    The ability to monitor and control distinct states is at the heart of emerging quantum technologies. The valley pseudospin in transition metal dichalcogenide (TMDC) monolayers is a promising degree of freedom for such control, with the optical Stark effect allowing for valley-selective manipulation of energy levels in WS2 and WSe2 using ultrafast optical pulses. Despite these advances, understanding of valley-sensitive optical Stark shifts in TMDCs has been limited by reflectance-based detection methods where the signal is small and prone to background effects. More sensitive polarization-based spectroscopy is required to better probe ultrafast Stark shifts for all-optical manipulation of valley energy levels. Here, we show time-resolved Kerr rotation to be a more sensitive probe of the valley-selective optical Stark effect in monolayer TMDCs. Compared to the established time-resolved reflectance methods, Kerr rotation is less sensitive to background effects. Kerr rotation provides a fivefold improvement in the signal-to-noise ratio of the Stark effect optical signal and a more precise estimate of the energy shift. This increased sensitivity allows for observation of an optical Stark shift in monolayer MoS2 that exhibits both valley and energy selectivity, demonstrating the promise of this method for investigating this effect in other layered materials and heterostructures.

  12. Real-time motional Stark effect in jet

    International Nuclear Information System (INIS)

    Alves, D.; Stephen, A.; Hawkes, N.; Dalley, S.; Goodyear, A.; Felton, R.; Joffrin, E.; Fernandes, H.

    2004-01-01

    The increasing importance of real-time measurements and control systems in JET experiments, regarding e.g. Internal Transport Barrier (ITB) and q-profile control, has motivated the development of a real-time motional Stark effect (MSE) system. The MSE diagnostic allows the measurement of local magnetic fields in different locations along the neutral beam path providing, therefore, local measurement of the current and q-profiles. Recently in JET, an upgrade of the MSE diagnostic has been implemented, incorporating a totally new system which allows the use of this diagnostic as a real-time control tool as well as an extended data source for off-line analysis. This paper will briefly describe the technical features of the real-time diagnostic with main focus on the system architecture, which consists of a VME crate hosting three PowerPC processor boards and a fast ADC, all connected via Front Panel Data Port (FPDP). The DSP algorithm implements a lockin-amplifier required to demodulate the JET MSE signals. Some applications for the system will be covered such as: feeding the real-time equilibrium reconstruction code (EQUINOX) and allowing the full coverage analysis of the Neutral Beam time window. A brief comparison between the real-time MSE analysis and the off-line analysis will also be presented

  13. Faraday-Shielded dc Stark-Shift-Free Optical Lattice Clock

    Science.gov (United States)

    Beloy, K.; Zhang, X.; McGrew, W. F.; Hinkley, N.; Yoon, T. H.; Nicolodi, D.; Fasano, R. J.; Schäffer, S. A.; Brown, R. C.; Ludlow, A. D.

    2018-05-01

    We demonstrate the absence of a dc Stark shift in an ytterbium optical lattice clock. Stray electric fields are suppressed through the introduction of an in-vacuum Faraday shield. Still, the effectiveness of the shielding must be experimentally assessed. Such diagnostics are accomplished by applying high voltage to six electrodes, which are grounded in normal operation to form part of the Faraday shield. Our measurements place a constraint on the dc Stark shift at the 10-20 level, in units of the clock frequency. Moreover, we discuss a potential source of error in strategies to precisely measure or cancel nonzero dc Stark shifts, attributed to field gradients coupled with the finite spatial extent of the lattice-trapped atoms. With this consideration, we find that Faraday shielding, complemented with experimental validation, provides both a practically appealing and effective solution to the problem of dc Stark shifts in optical lattice clocks.

  14. Dipole transitions and Stark effect in the charge-dyon system

    International Nuclear Information System (INIS)

    Mardoyan, Levon; Nersessian, Armen; Sarkisyan, Hayk; Yeghikyan, Vahagn

    2007-01-01

    We consider the dipole transitions and the linear and quadratic Stark effects in the MICZ-Kepler system interpreted as a charge-dyon system. We show that while the linear Stark effect in the ground state is proportional to the azimuth quantum number (and to the sign of the monopole number), the quadratic Stark effect in the ground state is independent of the signs of the azimuth and monopole numbers

  15. Improved signal analysis for motional Stark effect data

    International Nuclear Information System (INIS)

    Makowski, M.A.; Allen, S.L.; Ellis, R.; Geer, R.; Jayakumar, R.J.; Moller, J.M.; Rice, B.W.

    2005-01-01

    Nonideal effects in the optical train of the motional Stark effect diagnostic have been modeled using the Mueller matrix formalism. The effects examined are birefringence in the vacuum windows, an imperfect reflective mirror, and signal pollution due to the presence of a circularly polarized light component. Relations for the measured intensity ratio are developed for each case. These relations suggest fitting functions to more accurately model the calibration data. One particular function, termed the tangent offset model, is found to fit the data for all channels better than the currently used tangent slope function. Careful analysis of the calibration data with the fitting functions reveals that a nonideal effect is present in the edge array and is attributed to nonideal performance of a mirror in that system. The result of applying the fitting function to the analysis of our data has been to improve the equilibrium reconstruction

  16. Rydberg State Stark Spectroscopy and Applications to Plasma Diagnostics

    Science.gov (United States)

    1990-03-01

    Bayfield47 provides an excellent review of the AC Stark effect, in which the primary effect is Rabi splitting. Several authors48 , 49, 50 have...purity of the spectrum indicates that the field present is dominantly anisotropic . 53 n:26NEON LINE n=35 0 n= 40 p.- n=45 IL 0 31975 31950 31925 31900...applied (axial) electric field which is anisotropic , so pure polarization spectra can be recorded. The intensity profile of the Am = 0 polarization is

  17. Motional Stark Effect measurements of the local magnetic field in high temperature fusion plasmas

    Science.gov (United States)

    Wolf, R. C.; Bock, A.; Ford, O. P.; Reimer, R.; Burckhart, A.; Dinklage, A.; Hobirk, J.; Howard, J.; Reich, M.; Stober, J.

    2015-10-01

    The utilization of the Motional Stark Effect (MSE) experienced by the neutral hydrogen or deuterium injected into magnetically confined high temperature plasmas is a well established technique to infer the internal magnetic field distribution of fusion experiments. In their rest frame, the neutral atoms experience a Lorentz electric field, EL = v × B, which results in a characteristic line splitting and polarized line emission. The different properties of the Stark multiplet allow inferring, both the magnetic field strength and the orientation of the magnetic field vector. Besides recording the full MSE spectrum, several types of polarimeters have been developed to measure the polarization direction of the Stark line emission. To test physics models of the magnetic field distribution and dynamics, the accuracy requirements are quite demanding. In view of these requirements, the capabilities and issues of the different techniques are discussed, including the influence of the Zeeman Effect and the sensitivity to radial electric fields. A newly developed Imaging MSE system, which has been tested on the ASDEX Upgrade tokamak, is presented. The sensitivity allows to resolve sawtooth oscillations. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  18. Variable scaling method and Stark effect in hydrogen atom

    International Nuclear Information System (INIS)

    Choudhury, R.K.R.; Ghosh, B.

    1983-09-01

    By relating the Stark effect problem in hydrogen-like atoms to that of the spherical anharmonic oscillator we have found simple formulas for energy eigenvalues for the Stark effect. Matrix elements have been calculated using 0(2,1) algebra technique after Armstrong and then the variable scaling method has been used to find optimal solutions. Our numerical results are compared with those of Hioe and Yoo and also with the results obtained by Lanczos. (author)

  19. Direct measurements of safety factor profiles with motional Stark effect for KSTAR tokamak discharges with internal transport barriers

    Science.gov (United States)

    Ko, J.; Chung, J.

    2017-06-01

    The safety factor profile evolutions have been measured from the plasma discharges with the external current drive mechanism such as the multi-ion-source neutral beam injection for the Korea Superconducting Tokamak Advanced Research (KSTAR) for the first time. This measurement has been possible by the newly installed motional Stark effect (MSE) diagnostic system that utilizes the polarized Balmer-alpha emission from the energetic neutral deuterium atoms induced by the Stark effect under the Lorentz electric field. The 25-channel KSTAR MSE diagnostic is based on the conventional photoelastic modulator approach with the spatial and temporal resolutions less than 2 cm (for the most of the channels except 2 to 3 channels inside the magnetic axis) and about 10 ms, respectively. The strong Faraday rotation imposed on the optical elements in the diagnostic system is calibrated out from a separate and well-designed polarization measurement procedure using an in-vessel reference polarizer during the toroidal-field ramp-up phase before the plasma experiment starts. The combination of the non-inductive current drive during the ramp-up and shape control enables the formation of the internal transport barrier where the pitch angle profiles indicate flat or slightly hollow profiles in the safety factor.

  20. Regularities And Irregularities Of The Stark Parameters For Single Ionized Noble Gases

    Science.gov (United States)

    Peláez, R. J.; Djurovic, S.; Cirišan, M.; Aparicio, J. A.; Mar S.

    2010-07-01

    Spectroscopy of ionized noble gases has a great importance for the laboratory and astrophysical plasmas. Generally, spectra of inert gases are important for many physics areas, for example laser physics, fusion diagnostics, photoelectron spectroscopy, collision physics, astrophysics etc. Stark halfwidths as well as shifts of spectral lines are usually employed for plasma diagnostic purposes. For example atomic data of argon krypton and xenon will be useful for the spectral diagnostic of ITER. In addition, the software used for stellar atmosphere simulation like TMAP, and SMART require a large amount of atomic and spectroscopic data. Availability of these parameters will be useful for a further development of stellar atmosphere and evolution models. Stark parameters data of spectral lines can also be useful for verification of theoretical calculations and investigation of regularities and systematic trends of these parameters within a multiplet, supermultiplet or transition array. In the last years, different trends and regularities of Stark parameters (halwidths and shifts of spectral lines) have been analyzed. The conditions related with atomic structure of the element as well as plasma conditions are responsible for regular or irregular behaviors of the Stark parameters. The absence of very close perturbing levels makes Ne II as a good candidate for analysis of the regularities. Other two considered elements Kr II and Xe II with complex spectra present strong perturbations and in some cases an irregularities in Stark parameters appear. In this work we analyze the influence of the perturbations to Stark parameters within the multiplets.

  1. Semiconductor-metal transition induced by giant Stark effect in blue phosphorene nanoribbons

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Peng-Yu; Chen, Shi-Zhang; Zhou, Wu-Xing; Chen, Ke-Qiu, E-mail: keqiuchen@hnu.edu.cn

    2017-06-28

    The electronic structures and transport properties in monolayer blue phosphorene nanoribbons (BPNRs) with transverse electric field have been studied by using density functional theory and nonequilibrium Green's functions method. The results show that the band gaps of BPNRs with both armchair and zigzag edges are linearly decreased with the increasing of the strength of transverse electric field. A semiconductor-metal transition occurs when the electric field strength reaches to 5 V/nm. The Stark coefficient presents a linear dependency on BPNRs widths, and the slopes of both zBPNRs and aBPNRs are 0.41 and 0.54, respectively, which shows a giant Stark effect occurs. Our studies show that the semiconductor-metal transition originates from the giant Stark effect. - Highlights: • The electronic transport in blue phosphorene nanoribbons. • Semiconductor-metal transition can be observed. • The semiconductor-metal transition originates from the giant Stark effect.

  2. Measurements of the internal magnetic field on DIII-D using intensity and spacing of the motional Stark multiplet.

    Science.gov (United States)

    Pablant, N A; Burrell, K H; Groebner, R J; Kaplan, D H; Holcomb, C T

    2008-10-01

    We describe a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of Stark split D(alpha) emission from the neutral beams. This system, named B-Stark, has been recently installed on the DIII-D tokamak. To find the magnetic pitch angle, we use the ratio of the intensities of the pi(3) and sigma(1) lines. These lines originate from the same upper level and so are not dependent on the level populations. In future devices, such as ITER, this technique may have advantages over diagnostics based on MSE polarimetry. We have done an optimization of the viewing direction for the available ports on DIII-D to choose the installation location. With this placement, we have a near optimal viewing angle of 59.6 degrees from the vertical direction. All hardware has been installed for one chord, and we have been routinely taking data since January 2007. We fit the spectra using a simple Stark model in which the upper level populations of the D(alpha) transition are treated as free variables. The magnitude and direction of the magnetic field obtained using this diagnostic technique compare well with measurements from MSE polarimetry and EFIT.

  3. Stark broadening in cold plasmas with low electron densities calibrated with Thomson scattering

    International Nuclear Information System (INIS)

    Palomares, J.M.; Hübner, S.; Carbone, E.A.D.; Vries, N. de; Veldhuizen, E.M. de; Sola, A.; Gamero, A.; Mullen, J.J.A.M. van der

    2012-01-01

    In the present work Stark broadening measurements have been carried out on low electron density (n e 19 m −3 ) and (relatively) low gas temperature (T g e . - Highlights: ► Stark broadening measurements at low density and temperature conditions ► Calibration with Thomson scattering ► Indications of the non-Lorentzian shape of the Stark broadening ► Impossibility of simultaneous diagnostic of gas temperature and electron density

  4. A Stark-tuned, far-infrared laser for high frequency plasma diagnostics

    International Nuclear Information System (INIS)

    Mansfield, D.K.; Vocaturo, M.; Guttadora, L.; Rockmore, M.; Micai, K.; Krug, P.A.

    1992-03-01

    A Stark-tuned optically pumped far-infrared methanol laser operating at 119 micrometers has been built. The laser is designed to operate at high power while exhibiting a well-separated Stark doublet. At a pump power of 65 Watts and electric field of 1 kV/cm the laser has delivered over 100 mW c.w. while exhibiting a frequency splitting of 34 MHz. These parameters indicate that this laser would be suitable for use in the present generation of modulated interferometers on large thermonuclear plasma devices. The achieved modulation frequency is more than an order of magnitude higher than could be achieved using standard techniques

  5. Stark effect in finite-barrier quantum wells, wires, and dots

    International Nuclear Information System (INIS)

    Pedersen, Thomas Garm

    2017-01-01

    The properties of confined carriers in low-dimensional nanostructures can be controlled by external electric fields and an important manifestation is the Stark shift of quantized energy levels. Here, a unifying analytic theory for the Stark effect in arbitrary dimensional nanostructures is presented. The crucial role of finite potential barriers is stressed, in particular, for three-dimensional confinement. Applying the theory to CdSe quantum dots, finite barriers are shown to improve significantly the agreement with experiments. (paper)

  6. A temporally and spatially resolved electron density diagnostic method for the edge plasma based on Stark broadening

    Energy Technology Data Exchange (ETDEWEB)

    Zafar, A., E-mail: zafara@ornl.gov [Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States); Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830 (United States); Martin, E. H.; Isler, R. C.; Caughman, J. B. O. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830 (United States); Shannon, S. C. [Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States)

    2016-11-15

    An electron density diagnostic (≥10{sup 10} cm{sup −3}) capable of high temporal (ms) and spatial (mm) resolution is currently under development at Oak Ridge National Laboratory. The diagnostic is based on measuring the Stark broadened, Doppler-free spectral line profile of the n = 6–2 hydrogen Balmer series transition. The profile is then fit to a fully quantum mechanical model including the appropriate electric and magnetic field operators. The quasi-static approach used to calculate the Doppler-free spectral line profile is outlined here and the results from the model are presented for H-δ spectra for electron densities of 10{sup 10}–10{sup 13} cm{sup −3}. The profile shows complex behavior due to the interaction between the magnetic substates of the atom.

  7. Stark Broadening and White Dwarfs

    Directory of Open Access Journals (Sweden)

    Dimitrijević Milan S.

    2011-12-01

    Full Text Available White dwarf and pre-white dwarfs are the best types of stars for the application of Stark broadening research results in astrophysics, since in the atmospheres of these stars physical conditions are very favorable for this line broadening mechanism - in hot hydrogen-deficient white dwarfs and pre-white dwarfs Teff = 75 000–180 000 K and log g = 5.5–8 [cgs]. Even for much cooler DA and DB white dwarfs with the typical effective temperatures 10 000-20 000 K, Stark broadening is usually the dominant broadening mechanism. In this review, Stark broadening in white dwarf spectra is considered, and the attention is drawn to the STARK-B database (http://stark-b.obspm.fr/, containing the parameters needed for analysis and synthesis of white dwarf spectra, as well as for the collective efforts to develop the Virtual Atomic and Molecular Data Center.

  8. Ab initio modeling of the motional Stark effect on MAST

    International Nuclear Information System (INIS)

    De Bock, M. F. M.; Conway, N. J.; Walsh, M. J.; Carolan, P. G.; Hawkes, N. C.

    2008-01-01

    A multichord motional Stark effect (MSE) system has recently been built on the MAST tokamak. In MAST the π and σ lines of the MSE spectrum overlap due to the low magnetic field typical for present day spherical tokamaks. Also, the field curvature results in a large change in the pitch angle over the observation volume. The measured polarization angle does not relate to one local pitch angle but to an integration over all pitch angles in the observation volume. The velocity distribution of the neutral beam further complicates the measurement. To take into account volume effects and velocity distribution, an ab initio code was written that simulates the MSE spectrum on MAST. The code is modular and can easily be adjusted for other tokamaks. The code returns the intensity, polarized fraction, and polarization angle as a function of wavelength. Results of the code are presented, showing the effect on depolarization and wavelength dependence of the polarization angle. The code is used to optimize the design and calibration of the MSE diagnostic.

  9. Asymmetry of Stark-broadened Layman lines from laser-produced plasmas

    International Nuclear Information System (INIS)

    Joyce, R.F.; Woltz, L.A.; Hooper, C.F. Jr.

    1986-01-01

    This paper discusses three significant causes of spectral line asymmetry: the ion-quadrupole interaction, the quadratic Stark effect and fine structure splitting that are included in the calculation of Lyman line profiles emitted by highly-ionized hydrogenic radiators in a dense, hot plasma. The line asymmetries are shown to be strongly dependent on the plasma density, indicating that the asymmetry may be of use as a density diagnostic

  10. H{sub {beta}} Stark broadening in cold plasmas with low electron densities calibrated with Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Palomares, J.M., E-mail: j.m.palomares-linares@tue.nl [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Huebner, S.; Carbone, E.A.D.; Vries, N. de; Veldhuizen, E.M. de [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Sola, A.; Gamero, A. [Departamento de Fisica, Universidad de Cordoba, Campus de Rabanales, ed. C-2, 14071 Cordoba (Spain); Mullen, J.J.A.M. van der [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands)

    2012-07-15

    In the present work Stark broadening measurements have been carried out on low electron density (n{sub e} < 5{center_dot}10{sup 19} m{sup -3}) and (relatively) low gas temperature (T{sub g} < 1100 K) argon-hydrogen plasma, under low-intermediate pressure conditions (3 mbar-40 mbar). A line fitting procedure is used to separate the effects of the different broadening mechanisms (e.g. Doppler and instrumental broadening) from the Stark broadening. A Stark broadening theory is extrapolated to lower electron density values, below its theoretical validity regime. Thomson scattering measurements are used to calibrate and validate the procedure. The results show an agreement within 20%, what validates the use of this Stark broadening method under such low density conditions. It is also found that Stark broadened profiles cannot be assumed to be purely Lorentzian. Such an assumption would lead to an underestimation of the electron density. This implies that independent information on the gas temperature is needed to find the correct values of n{sub e}. - Highlights: Black-Right-Pointing-Pointer Stark broadening measurements at low density and temperature conditions Black-Right-Pointing-Pointer Calibration with Thomson scattering Black-Right-Pointing-Pointer Indications of the non-Lorentzian shape of the Stark broadening Black-Right-Pointing-Pointer Impossibility of simultaneous diagnostic of gas temperature and electron density.

  11. Stark effect in Rydberg states of helium and barium

    International Nuclear Information System (INIS)

    Lahaije, C.T.W.

    1989-01-01

    This thesis, which deals with the effect of an electric field up to moderate field strengths on atoms with two valence electrons outside closed shells, in casu helium and barium, contains chapter in which the linear Stark effect in the 1 snp 1, 3 p Rydberg states of helium (n around 40) has been studied in a CW laser-atomic beam experiment. The evolution of the angular momentum manifolds into the n-mixing regime was followed and avoided level crossings were observed. Stark manifolds were also calculated by diagonalization of the complete energy matrix in the presence of an electric field. It turned out to be necessary to include up to five n-values in the calculations already at moderate values of the field to reproduce the data within the experimental accuracy (a few MHz), especially in the regime of the avoided crossings. (author). 147 refs.; 30 figs.; 8 tabs

  12. Stark effect measurements on monomers and trimers of reconstituted light-harvesting complex II of plants

    NARCIS (Netherlands)

    Palacios, M.A.; Caffarri, S.; Bassi, R.; Grondelle, van R.; Amerongen, van H.

    2004-01-01

    The electric-field induced absorption changes (Stark effect) of reconstituted light-harvesting complex II (LHCII) in different oligomerisation states - monomers and trimers - with different xanthophyll content have been probed at 77 K. The Stark spectra of the reconstituted control samples,

  13. Dynamic Stark broadening as the Dicke narrowing effect

    International Nuclear Information System (INIS)

    Calisti, A.; Mosse, C.; Ferri, S.; Talin, B.; Rosmej, F.; Bureyeva, L. A.; Lisitsa, V. S.

    2010-01-01

    A very fast method to account for charged particle dynamics effects in calculations of spectral line shape emitted by plasmas is presented. This method is based on a formulation of the frequency fluctuation model (FFM), which provides an expression of the dynamic line shape as a functional of the static distribution of frequencies. Thus, the main numerical work rests on the calculation of the quasistatic Stark profile. This method for taking into account ion dynamics allows a very fast and accurate calculation of Stark broadening of atomic hydrogen high-n series emission lines. It is not limited to hydrogen spectra. Results on helium-β and Lyman-α lines emitted by argon in microballoon implosion experiment conditions compared with experimental data and simulation results are also presented. The present approach reduces the computer time by more than 2 orders of magnitude as compared with the original FFM with an improvement of the calculation precision, and it opens broad possibilities for its application in spectral line-shape codes.

  14. Quantum-Confined Stark Effect in Ensemble of Colloidal Semiconductor Quantum Dots

    International Nuclear Information System (INIS)

    Zhi-Bing, Wang; Hui-Chao, Zhang; Jia-Yu, Zhang; Su, Huaipeng; Wang, Y. Andrew

    2010-01-01

    The presence of a strong, changing, randomly-oriented, local electric field, which is induced by the photo-ionization that occurs universally in colloidal semiconductor quantum dots (QDs), makes it difficult to observe the quantum-confined Stark effect in ensemble of colloidal QDs. We propose a way to inhibit such a random electric field, and a clear quantum-confined Stark shift is observed directly in close-packed colloidal QDs. Besides the applications in optical switches and modulators, our experimental results indicate how the oscillator strengths of the optical transitions are changed under external electric fields. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  15. Case studies on recent Stark broadening calculations and STARK-B database development in the framework of the European project VAMDC (Virtual Atomic and Molecular Data Center)

    International Nuclear Information System (INIS)

    Sahal-Brechot, S

    2010-01-01

    Stark broadening theories and calculations have been extensively developed for about 50 years. The theory can now be considered as mature for many applications, especially for accurate spectroscopic diagnostics and modelling. In astrophysics, with the increasing sensitivity of observations and spectral resolution, in all domains of wavelengths from far UV to infrared, it has become possible to develop realistic models of interiors and atmospheres of stars and interpret their evolution and the creation of elements through nuclear reactions. For hot stars, especially white dwarfs, Stark broadening is the dominant collisional line broadening process. This requires the knowledge of numerous profiles, especially for trace elements, which are used as useful probes for modern spectroscopic diagnostics. Hence, calculations based on a simple but enough accurate and fast method, are necessary for obtaining numerous results. Ab initio calculations are a growing domain of development. Nowadays, the access to such data via an on line database becomes crucial. This is the object of STARK-B, which is a collaborative project between the Paris Observatory and the Astronomical Observatory of Belgrade. It is a database of calculated widths and shifts of isolated lines of atoms and ions due to electron and ion collisions. It is devoted to modelling and spectroscopic diagnostics of stellar atmospheres and envelopes. In addition, it is relevant to laboratory plasmas, laser equipments and technological plasmas. It is a part of VAMDC (Virtual Atomic and Molecular Data Centre), which is an European Union funded collaboration between groups involved in the generation and use of atomic and molecular data.

  16. The stark effect in intense field. 2

    International Nuclear Information System (INIS)

    Popov, V.S.; Mur, V.D.; Sergeev, A.V.; Weinberg, V.M.

    1987-01-01

    The problem of hydrogen atom in homogeneous electric field is considered. The Stark shifts and widths of atomic levels are computed by summation of divergent perturbation series and by 1/n-expansion - up to E values comparable with the field on the electron orbit. The results of the calculations are presented for the following sequences of states: |n 1 ,0,0>, |0,n 2 ,0>, |n 1 ,n 1 ,0>, as well as for all states with n=2 and 3 (n is the principal quantum number). The Stark shifts and widths of Rydberg states (with n=15-30) in electric field which exceeds the classical ionization threshold are computed. The results of our calculations agree with experiment

  17. Spectral-Kinetic Coupling and Effect of Microfield Rotation on Stark Broadening in Plasmas

    Directory of Open Access Journals (Sweden)

    Alexander V. Demura

    2014-07-01

    Full Text Available The study deals with two conceptual problems in the theory of Stark broadening by plasmas. One problem is the assumption of the density matrix diagonality in the calculation of spectral line profiles. This assumption is closely related to the definition of zero wave functions basis within which the density matrix is assumed to be diagonal, and obviously violated under the basis change. A consistent use of density matrix in the theoretical scheme inevitably leads to interdependence of atomic kinetics, describing the population of atomic states with the Stark profiles of spectral lines, i.e., to spectral-kinetic coupling. The other problem is connected with the study of the influence of microfield fluctuations on Stark profiles. Here the main results of the perturbative approach to ion dynamics, called the theory of thermal corrections (TTC, are presented, within which the main contribution to effects of ion dynamics is due to microfield fluctuations caused by rotations. In the present study the qualitative behavior of the Stark profiles in the line center within predictions of TTC is confirmed, using non-perturbative computer simulations.

  18. Electroreflectance investigations of quantum confined Stark effect in GaN quantum wells

    International Nuclear Information System (INIS)

    Drabinska, A; Pakula, K; Baranowski, J M; Wysmolek, A

    2010-01-01

    In this paper we present room temperature electroreflectance studies of GaN quantum wells (QWs) with different well width. The electroreflectance measurements were performed with external voltage applied to the structure therefore it was possible to tune the electric field inside QW up to its completely screening and furthermore even reversing it. The analysis of QW spectral lines showed the Stark shift dependence on applied voltage and well width reaching about 35 meV for highest voltage and widest well width. It was possible to obtain the condition of zero electric field in QW. Both broadening and amplitude of QW lines are minimal for zero electric field and increases for increasing electric field in QW. The energy transition is maximum for zero electric field and for increasing electric field it decreases due to Stark effect. Neither amplitude and broadening parameter nor energy transition does not depend on the direction of electric field. Only parameter that depends on the direction of electric field in QW is phase of the signal. The analysis of Franz-Keldysh oscillations (FKOs) from AlGaN barriers allowed to calculate the real electric field dependence on applied voltage and therefore to obtain the Stark shift dependence on electric field. The Stark shift reached from -12 meV to -35 meV for 450 kV/cm depending on the well width. This conditions were established for highest forward voltages therefore this is the value of electric field and Stark shift caused only by the intrinsic polarization of nitrides.

  19. Diagnostic development for current density profile control at KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Ko, J., E-mail: jinseok@nfri.re.kr [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); University of Science and Technology, Daejeon 34113 (Korea, Republic of); Chung, J. [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); Messmer, M.C.C. [Department of Applied Physics, Eindhoven University of Technology, Eindhoven (Netherlands)

    2016-11-01

    Highlights: • The motional Stark effect (MSE) diagnostic installed at KSTAR. • Engineering challenges and solutions on the design and fabrication of the front optics housing and filter modules. • Characterization of the bandpass filters and the responses to polarized light. - Abstract: The current density profile diagnostics are critical for the control of the steady-state burning plasma operations. A multi-channel motional Stark effect (MSE) diagnostic system has been implemented for the measurements of the internal magnetic field structures that constrain the magnetic equilibrium reconstruction to accurately produce the tokamak safety factor and current density profiles for the Korea Superconducting Tokamak Advanced Research (KSTAR). This work presents the design and fabrication of the front optics and the filter modules and the calibration activities for the MSE diagnostic at KSTAR.

  20. Stark shift and g-factor tuning in nanowires with Rashba effect

    International Nuclear Information System (INIS)

    Alhaddad, Iman; Habanjar, Khulud; Sakr, M.R.

    2015-01-01

    We report on the Stark shift of the energy subbands and the possibility of tuning the g-factor of electrons in nanowires subjected to external magnetic field. The electric field is applied along the direction of quantum confinement. Our analysis is based on numerical and perturbation calculations in the weak Rashba regime. For in-plane magnetic fields, the Stark shift is rigid and depends on the square of the electric field. Such rigid shift results in a field independent g-factor. Perpendicular magnetic fields induce a similar Stark shift accompanied by a lateral displacement of the energy spectra that is linear in the electric field. In this case, the g-factor shows square dependence on weak electric fields that varies with the subband index. However, in strong electric fields, the g-factor becomes subband independent and varies linearly with the field. - Highlights: • Energy spectra of electrons in nanowires are calculated in the weak Rashba regime. • For in-plane magnetic field, the Stark shift is rigid and the g-factor cannot be tuned. • Perpendicular magnetic fields add lateral displacement to the Stark shift. • The g-factor can be tuned by external electric field in this case. • The tuning of the g-factor is linear and unique for all subbands at high fields

  1. Stark shift and g-factor tuning in nanowires with Rashba effect

    Energy Technology Data Exchange (ETDEWEB)

    Alhaddad, Iman; Habanjar, Khulud [Department of Physics, Faculty of Science, Beirut Arab University, P.O. Box 11, 5020 Riad El Solh, 11072809 - Beirut (Lebanon); Sakr, M.R., E-mail: msakr@alexu.edu.eg [Department of Physics, Faculty of Science, Beirut Arab University, P.O. Box 11, 5020 Riad El Solh, 11072809 - Beirut (Lebanon); Department of Physics, Faculty of Science, Alexandria University, Moharram Bek, Alexandria 21511 (Egypt)

    2015-10-15

    We report on the Stark shift of the energy subbands and the possibility of tuning the g-factor of electrons in nanowires subjected to external magnetic field. The electric field is applied along the direction of quantum confinement. Our analysis is based on numerical and perturbation calculations in the weak Rashba regime. For in-plane magnetic fields, the Stark shift is rigid and depends on the square of the electric field. Such rigid shift results in a field independent g-factor. Perpendicular magnetic fields induce a similar Stark shift accompanied by a lateral displacement of the energy spectra that is linear in the electric field. In this case, the g-factor shows square dependence on weak electric fields that varies with the subband index. However, in strong electric fields, the g-factor becomes subband independent and varies linearly with the field. - Highlights: • Energy spectra of electrons in nanowires are calculated in the weak Rashba regime. • For in-plane magnetic field, the Stark shift is rigid and the g-factor cannot be tuned. • Perpendicular magnetic fields add lateral displacement to the Stark shift. • The g-factor can be tuned by external electric field in this case. • The tuning of the g-factor is linear and unique for all subbands at high fields.

  2. Overview of equilibrium reconstruction on DIII-D using new measurements from an expanded motional Stark effect diagnostic

    International Nuclear Information System (INIS)

    Holcomb, C; Makowski, M; Allen, S; Meyer, W; Van Zeeland, M

    2008-01-01

    Motional Stark effect (MSE) measurements constrain equilibrium reconstruction of DIII-D tokamak plasmas using the equilibrium code EFIT. In 2007, two new MSE arrays were brought online, bringing the system to three core arrays, two edge arrays, and 64 total channels. We present the first EFIT reconstructions using this expanded system. Safety factor and E R profiles produced by fitting to data from the two new arrays and one of the other three agree well with independent measurements. Comparison of the data from the three arrays that view the core shows that one of the older arrays is inconsistent with the other two unless the measured calibration factors for this array are adjusted. The required adjustments depend on toroidal field and plasma current direction, and on still other uncertain factors that change as the plasma evolves. We discuss possible sources of calibration error for this array

  3. Plasma density characterization at SPARC-LAB through Stark broadening of Hydrogen spectral lines

    Energy Technology Data Exchange (ETDEWEB)

    Filippi, F., E-mail: francesco.filippi@roma1.infn.it [Dipartimento di Scienze di Base e Applicate per l' Ingegneria (SBAI), ‘Sapienza’ Università di Roma, Via A. Scarpa 14-16, 00161 Roma (Italy); INFN-Roma1, Piazzale Aldo Moro, 2 00161 Roma (Italy); Anania, M.P.; Bellaveglia, M.; Biagioni, A.; Chiadroni, E. [Laboratori Nazionali di Frascati, INFN, Via E. Fermi, Frascati (Italy); Cianchi, A. [Dipartimento di Fisica, Universitá di Roma Tor Vergata, Via della Ricerca Scientifica 1, 00133 Roma (Italy); Di Giovenale, D.; Di Pirro, G.; Ferrario, M. [Laboratori Nazionali di Frascati, INFN, Via E. Fermi, Frascati (Italy); Mostacci, A.; Palumbo, L. [Dipartimento di Scienze di Base e Applicate per l' Ingegneria (SBAI), ‘Sapienza’ Università di Roma, Via A. Scarpa 14-16, 00161 Roma (Italy); INFN-Roma1, Piazzale Aldo Moro, 2 00161 Roma (Italy); Pompili, R.; Shpakov, V.; Vaccarezza, C.; Villa, F. [Laboratori Nazionali di Frascati, INFN, Via E. Fermi, Frascati (Italy); Zigler, A. [Hebrew University of Jerusalem, Jerusalem 91904 (Israel)

    2016-09-01

    Plasma-based acceleration techniques are of great interest for future, compact accelerators due to their high accelerating gradient. Both particle-driven and laser-driven Plasma Wakefield Acceleration experiments are foreseen at the SPARC-LAB Test Facility (INFN National Laboratories of Frascati, Italy), with the aim to accelerate high-brightness electron beams. In order to optimize the efficiency of the acceleration in the plasma and preserve the quality of the accelerated beam, the knowledge of the plasma electron density is mandatory. The Stark broadening of the Hydrogen spectral lines is one of the candidates used to characterize plasma density. The implementation of this diagnostic for plasma-based experiments at SPARC-LAB is presented. - Highlights: • Stark broadening of Hydrogen lines has been measured to determine plasma density. • Plasma density diagnostic tool for plasma-based experiments at SPARC-LAB is presented. • Plasma density in tapered laser triggered ablative capillary discharge was measured. • Results of plasma density measurements in ablative capillaries are shown.

  4. Plasma density characterization at SPARC-LAB through Stark broadening of Hydrogen spectral lines

    International Nuclear Information System (INIS)

    Filippi, F.; Anania, M.P.; Bellaveglia, M.; Biagioni, A.; Chiadroni, E.; Cianchi, A.; Di Giovenale, D.; Di Pirro, G.; Ferrario, M.; Mostacci, A.; Palumbo, L.; Pompili, R.; Shpakov, V.; Vaccarezza, C.; Villa, F.; Zigler, A.

    2016-01-01

    Plasma-based acceleration techniques are of great interest for future, compact accelerators due to their high accelerating gradient. Both particle-driven and laser-driven Plasma Wakefield Acceleration experiments are foreseen at the SPARC-LAB Test Facility (INFN National Laboratories of Frascati, Italy), with the aim to accelerate high-brightness electron beams. In order to optimize the efficiency of the acceleration in the plasma and preserve the quality of the accelerated beam, the knowledge of the plasma electron density is mandatory. The Stark broadening of the Hydrogen spectral lines is one of the candidates used to characterize plasma density. The implementation of this diagnostic for plasma-based experiments at SPARC-LAB is presented. - Highlights: • Stark broadening of Hydrogen lines has been measured to determine plasma density. • Plasma density diagnostic tool for plasma-based experiments at SPARC-LAB is presented. • Plasma density in tapered laser triggered ablative capillary discharge was measured. • Results of plasma density measurements in ablative capillaries are shown.

  5. Oscillator strength and quantum-confined Stark effect of excitons in a thin PbS quantum disk

    Science.gov (United States)

    Oukerroum, A.; El-Yadri, M.; El Aouami, A.; Feddi, E.; Dujardin, F.; Duque, C. A.; Sadoqi, M.; Long, G.

    2018-01-01

    In this paper, we report a study of the effect of a lateral electric field on a quantum-confined exciton in a thin PbS quantum disk. Our approach was performed in the framework of the effective mass theory and adiabatic approximation. The ground state energy and the stark shift were determined by using a variational method with an adequate trial wavefunction, by investigating a 2D oscillator strength under simultaneous consideration of the geometrical confinement and the electric field strength. Our results showed a strong dependence of the exciton binding and the Stark shift on the disk dimensions in both axial and longitudinal directions. On the other hand, our results also showed that the Stark shift’s dependence on the electric field is not purely quadratic but the linear contribution is also important and cannot be neglected, especially when the confinement gets weaker.

  6. Stark effect and polarizability of graphene quantum dots

    DEFF Research Database (Denmark)

    Pedersen, Thomas Garm

    2017-01-01

    The properties of graphene quantum dots can be manipulated via lateral electric fields. Treating electrons in such structures as confined massless Dirac fermions, we derive an analytical expression for the quadratic Stark shift valid for arbitrary angular momentum and quantum dot size. Moreover, we...

  7. Quantum confined Stark effect in Gaussian quantum wells: A tight-binding study

    International Nuclear Information System (INIS)

    Ramírez-Morales, A.; Martínez-Orozco, J. C.; Rodríguez-Vargas, I.

    2014-01-01

    The main characteristics of the quantum confined Stark effect (QCSE) are studied theoretically in quantum wells of Gaussian profile. The semi-empirical tight-binding model and the Green function formalism are applied in the numerical calculations. A comparison of the QCSE in quantum wells with different kinds of confining potential is presented

  8. Quantum confined Stark effect in Gaussian quantum wells: A tight-binding study

    Energy Technology Data Exchange (ETDEWEB)

    Ramírez-Morales, A.; Martínez-Orozco, J. C.; Rodríguez-Vargas, I. [Unidad Académica de Física, Universidad Autónoma de Zacatecas, Calzada Solidaridad Esquina Con Paseo La Bufa S/N, 98060 Zacatecas, Zac. (Mexico)

    2014-05-15

    The main characteristics of the quantum confined Stark effect (QCSE) are studied theoretically in quantum wells of Gaussian profile. The semi-empirical tight-binding model and the Green function formalism are applied in the numerical calculations. A comparison of the QCSE in quantum wells with different kinds of confining potential is presented.

  9. Stark resonances in disordered systems

    International Nuclear Information System (INIS)

    Grecchi, V.; Maioli, M.; Modena Univ.; Sacchetti, A.

    1992-01-01

    By slightly restricting the conditions given by Herbst and Howland, we prove the existence of resonances in the Stark effect of disordered systems (and atomic crystals) for large atomic mean distance. In the crystal case the ladders of resonances have the Wannier behavior for small complex field. (orig.)

  10. Laser-induced fluorescences due to quadrupole moment transition and Stark effect in a He glow discharge

    International Nuclear Information System (INIS)

    Sakai, Hisashi; Takiyama, Ken; Kimura, Masahiko; Yamasaki, Motokuni; Fujita, Toshiaki; Oda, Toshiatsu; Kawasaki, Ken.

    1993-01-01

    The electric quadrupole moment transition and the Stark effect are investigated in a He hollow cathode discharge with laser-induced fluorescence method. It is shown that the forbidden transition from 2 1 S to 3 1 D in the negative glow is dominantly due to the quadrupole moment transition. This absorption coefficient is obtained from the laser-induced fluorescence intensity measurement in which the collisional transfers are taken into account. The result agrees with the theoretical coefficient. In the cathode dark space the fluorescence due to the Stark effect is also observed. Spatial distribution of the fluorescence is discussed, compared with the electric field distribution in the dark space. (author)

  11. Stark broadening of hydrogen (1961); Sur l'effet stark dans les plasmas d'hydrogene (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Fidone, I [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France)

    1961-07-01

    The effect of electron impacts on the Stark broadening of hydrogen atoms has been considered using a Debye-Huckel potential instead of a cut-off limit for the integrals giving the shift and the half-width. A slight difference results which in a typical case is of the order of 12 - 15 per cent. The simple adiabatic impact approximation has been used. (author) [French] L'effet des chocs electroniques sur l'elargissement Stark des raies d'hydrogene est calcule avec le potentiel de Debye-Huckel au lieu de l'emploi du cut-off pour les integrales qui donnent le deplacement et l'elargissement de la raie. On obtient une faible difference qui, dans un cas typique, est de l'ordre de grandeur de 12 - 15 pour cent. L'approximation adiabatique a ete employee pour decrire les chocs. (auteur)

  12. Scattering theory for Stark Hamiltonians

    International Nuclear Information System (INIS)

    Jensen, Arne

    1994-01-01

    An introduction to the spectral and scattering theory for Schroedinger operators is given. An abstract short range scattering theory is developed. It is applied to perturbations of the Laplacian. Particular attention is paid to the study of Stark Hamiltonians. The main result is an explanation of the discrepancy between the classical and the quantum scattering theory for one-dimensional Stark Hamiltonians. (author). 47 refs

  13. The Stark effect of 1H and 4He+ in the beam foil source

    International Nuclear Information System (INIS)

    Doobov, M.H.; Hay, H.J.; Sofield, C.J.; Newton, C.S.

    1974-01-01

    The appearance of Stark patterns obtained with a beam-foil source differed from those characteristically obtained from gas discharge sources. In the former source excitation of the hydrogenic ions occurred in a brief time interval ( 14 s) during the passage of a high velocity unidirectional beam of ions which produces non-statistical population distributions for the Stark perturbed states. The relative intensities of Stark perturbed components of the Hsub(β) hydrogen line and the Fsub(α) ionized helium line have been measured in a beam-foil source. In each case an initial population of states of principal quantum number n = 4 due to radiative decay and Stark mixing, and comparing the resultant patterns with the observed patterns. The inferred population distributions indicate that the states of low orbital angular momentum (L) are preferentially populated, and alignment referred to the beam axis is produced such that states with lower z component of L are preferentially populated. (author)

  14. Dynamic Stark shift and alignment-to-orientation conversion

    International Nuclear Information System (INIS)

    Kuntz, Matthew C.; Hilborn, Robert C.; Spencer, Alison M.

    2002-01-01

    We have observed alignment-to-orientation conversion in the (5d6p) 1 P state of atomic barium due to the combined effects of a static Zeeman shift and a dynamic Stark shift associated with the electric field of a pulsed laser beam. The measurements yield a value for the frequency-dependent tensor polarizability of the state in reasonable agreement with a simple perturbation theory calculation. With a tunable laser producing the dynamic Stark shift, we can both enhance the magnitude of the effect by tuning close to a resonance and reverse the sign of the orientation by tuning above or below the resonance. This method of producing an oriented atomic state is quite general, and with easily available field strengths can produce large orientations

  15. DC Stark addressing for quantum memory in Tm:YAG

    Science.gov (United States)

    Gerasimov, Konstantin; Minnegaliev, Mansur; Urmancheev, Ravil; Moiseev, Sergey

    2017-10-01

    We observed a linear DC Stark effect for 3H6 - 3H4 optical transition of Tm3+ ions in Y3Al5O12. We observed that application of electric field pulse suppresses the two-pulse photon echo signal. If we then apply a second electric pulse of opposite polarity the echo signal is restored again, which indicates the linear nature of the observed effect. The effect is present despite the D2 symmetry of the Tm3+ sites that prohibits a linear Stark effect. Experimental data analysis shows that the observed electric field influence can be attributed to defects that break the local crystal field symmetry near Tm3+ ions. Using this effect we demonstrate selective retrieval of light pulses in two-pulse photon echo.

  16. A motional Stark effect diagnostic analysis routine for improved resolution of iota in the core of the large helical device.

    Science.gov (United States)

    Dobbins, T J; Ida, K; Suzuki, C; Yoshinuma, M; Kobayashi, T; Suzuki, Y; Yoshida, M

    2017-09-01

    A new Motional Stark Effect (MSE) analysis routine has been developed for improved spatial resolution in the core of the Large Helical Device (LHD). The routine was developed to reduce the dependency of the analysis on the Pfirsch-Schlüter (PS) current in the core. The technique used the change in the polarization angle as a function of flux in order to find the value of diota/dflux at each measurement location. By integrating inwards from the edge, the iota profile can be recovered from this method. This reduces the results' dependency on the PS current because the effect of the PS current on the MSE measurement is almost constant as a function of flux in the core; therefore, the uncertainty in the PS current has a minimal effect on the calculation of the iota profile. In addition, the VMEC database was remapped from flux into r/a space by interpolating in mode space in order to improve the database core resolution. These changes resulted in a much smoother iota profile, conforming more to the physics expectations of standard discharge scenarios in the core of the LHD.

  17. Deflection of atomic beams with isotope separation by optical resonance radiation using stimulated emission and the ac stark effect

    International Nuclear Information System (INIS)

    Bjorkholm, J.E.; Liao, P.F.H.

    1977-01-01

    Improved atomic beam deflection and improved isotope separation, even in vapors, is proposed by substituting the A.C. Stark effect for the baseband chirp of the pushing beam in the prior proposal by I. Nebenzahl et al., Applied Physics Letters, Vol. 25, page 327 (September 1974). The efficiency inherent in re-using the photons as in the Nebenzahl et al proposal is retained; but the external frequency chirpers are avoided. The entire process is performed by two pulses of monochromatic coherent light, thereby avoiding the complication of amplifying frequency-modulated light pulses. The A.C. Stark effect is provided by the second beam of coherent monochromatic light, which is sufficiently intense to chirp the energy levels of the atoms or isotopes of the atomic beam or vapor. Although, in general, the A.C. Stark effect will alter the isotope shift somewhat, it is not eliminated. In fact, the appropriate choice of frequencies of the pushing and chirping beams may even relax the requirements with respect to the isotope absorption line shift for effective separation. That is, it may make the isotope absorption lines more easily resolvable

  18. Stark-like electron transfer between quantum wells

    International Nuclear Information System (INIS)

    Dubovis, S.A.; Voronko, A.N.; Basharov, A.M.

    2008-01-01

    The Stark-like mechanism of electron transfer between two energy subband localized in remote quantum wells is examined theoretically. Estimations of major parameters of the problem in case of delta-function-wells model are adduced. Schematic model allowing experimental study of Stark-like transfer is proposed

  19. Diagnostics development for E-beam excited air channels

    Science.gov (United States)

    Eckstrom, D. J.; Dickenson, J. S.

    1982-02-01

    As the tempo of development of particle beam weapons increases, more detailed diagnostics of the interaction of the particle beam with the atmosphere are being proposed and implemented. Some of these diagnostics involve probing of the excited air channel with visible wavelength laser radiation. Examples include the use of visible wavelength interferometry to measure electron density profiles in the nose of the beam Ri81 and Stark shift measurements to determine self-induced electric fields Hi81, DR81. In these diagnostics, the change in laser intensity due to the desired diagnostic effect can be quite small, leading to the possibility that other effects, such as gas phase absorption, could seriously interfere with the measurement.

  20. Stark widths regularities within spectral series of sodium isoelectronic sequence

    Science.gov (United States)

    Trklja, Nora; Tapalaga, Irinel; Dojčinović, Ivan P.; Purić, Jagoš

    2018-02-01

    Stark widths within spectral series of sodium isoelectronic sequence have been studied. This is a unique approach that includes both neutrals and ions. Two levels of problem are considered: if the required atomic parameters are known, Stark widths can be calculated by some of the known methods (in present paper modified semiempirical formula has been used), but if there is a lack of parameters, regularities enable determination of Stark broadening data. In the framework of regularity research, Stark broadening dependence on environmental conditions and certain atomic parameters has been investigated. The aim of this work is to give a simple model, with minimum of required parameters, which can be used for calculation of Stark broadening data for any chosen transitions within sodium like emitters. Obtained relations were used for predictions of Stark widths for transitions that have not been measured or calculated yet. This system enables fast data processing by using of proposed theoretical model and it provides quality control and verification of obtained results.

  1. Higher order Stark effect and transition probabilities on hyperfine structure components of hydrogen like atoms

    Energy Technology Data Exchange (ETDEWEB)

    Pal' chikov, V.G. [National Research Institute for Physical-Technical and Radiotechnical Measurements - VNIIFTRI (Russian Federation)], E-mail: vitpal@mail.ru

    2000-08-15

    A quantum-electrodynamical (QED) perturbation theory is developed for hydrogen and hydrogen-like atomic systems with interaction between bound electrons and radiative field being treated as the perturbation. The dependence of the perturbed energy of levels on hyperfine structure (hfs) effects and on the higher-order Stark effect is investigated. Numerical results have been obtained for the transition probability between the hfs components of hydrogen-like bismuth.

  2. Stark effect of excitons in corrugated lateral surface superlattices: effect of centre-of-mass quantization

    International Nuclear Information System (INIS)

    Hong Sun

    1998-11-01

    The quantum confined Stark effect (QCSE) of excitons in GaAs/AlAs corrugated lateral surface superlattices (CLSSLs) is calculated. Blue and red shifts in the exciton energies are predicted for the heavy- and light-excitons in the CLSSLs, respectively, comparing with those in the unmodulated quantum well due to the different effective hole masses in the parallel direction. Sensitive dependence of the QCSE on the hole effective mass in the parallel direction is expected because of the ''centre-of-mass'' quantization (CMQ) induced by the periodic corrugated interfaces of the CLSSLs. The effect of the CMQ on the exciton mini-bands and the localization of the excitons in the CLSSLs is discussed. (author)

  3. Stark Broadening of Cr III Spectral Lines: DO White Dwarfs

    Directory of Open Access Journals (Sweden)

    Milan S. Dimitrijević

    2018-04-01

    Full Text Available Using the modified semiempirical method of Dimitrijević and Konjević, Stark widths have been calculated for six Cr III transitions, for an electron density of 10 17 cm ‒ 3 and for temperatures from 5000–80,000 K. Results have been used for the investigation of the influence of Stark broadening on spectral lines in cool DO white dwarf atmospheres. Calculated Stark widths will be implemented in the STARK-B database, which is also a part of the Virtual Atomic and Molecular Data Center (VAMDC.

  4. The giant Stark effect in armchair-edge phosphorene nanoribbons under a transverse electric field

    Science.gov (United States)

    Zhou, Benliang; Zhou, Benhu; Liu, Pu; Zhou, Guanghui

    2018-01-01

    We study the variation of electronic properties for armchair-edge phosphorene nanoribbons (APNRs) modulated by a transverse electric field. Within the tight-binding model Hamiltonian, and by solving the differential Schrödinger equation, we find that a band gap closure appears at the critical field due to the giant Stark effect for an APNR. The gap closure has no field polarity, and the gap varies quadratically for small fields but becomes linear for larger ones. We attribute the giant Stark effect to the broken edge degeneracy, i.e., the charge redistributions of the conduction band minimum and valence band maximum states localized at opposite edges induced by the field. By combined with the Green's function approach, it is shown that in the presence of the critical field a gap of density of states (DOS) disappears and a high value DOS turns up at the energy position of the band gap closure. Finally, as the field increases, we find the band gap decreases more rapidly and the gap closure occurs at smaller fields for wider ribbons. Both the band gap and DOS variations with the field show an insulator-metal transition induced by a transverse electric field for the APNR. Our results show that wider APNRs are more appreciable to design field-effect transistors.

  5. Cross-sectional nanophotoluminescence studies of Stark effects in self-assembled quantum dots

    International Nuclear Information System (INIS)

    Htoon, H.; Keto, J. W.; Baklenov, O.; Holmes, A. L. Jr.; Shih, C. K.

    2000-01-01

    By using a cross-sectional geometry, we show the capability to perform single-dot spectroscopy in self-assembled quantum dots using far-field optics. By using this method, we study the quantum-confined Stark effect in self-assembled quantum dots. For single-stack quantum dots (QDs), we find that the spectra are redshifted with an increase in electric field. For vertically coupled double-stack quantum dots, while most of the QDs are redshifted, some QDs show blueshifted spectra, which can be interpreted as an evidence of coupled QD molecules. (c) 2000 American Institute of Physics

  6. Stark shifting two-electron quantum dot

    International Nuclear Information System (INIS)

    Dineykhan, M.; Zhaugasheva, S.A.; Duysebaeva, K.S.

    2003-01-01

    Advances in modern technology make it possible to create semiconducting nano-structures (quantum dot) in which a finite number of electrons are 'captured' in a bounded volume. A quantum dot is associated with a quantum well formed at the interface, between two finite-size semiconductors owing to different positions of the forbidden gaps on the energy scale in these semiconductors. The possibility of monitoring and controlling the properties of quantum dots attracts considerable attention to these objects, as a new elemental basis for future generations of computers. The quantum-mechanical effects and image potential play a significant role in the description of the formation mechanism quantum dot, and determined the confinement potential in a two-electron quantum dot only for the spherical symmetric case. In the present talk, we considered the formation dynamics of two-electron quantum dot with violation of spherical symmetry. So, we have standard Stark potential. The energy spectrum two-electron quantum dot were calculated. Usually Stark interactions determined the tunneling phenomena between quantum dots

  7. Progress on the MSE diagnostic for ITER

    International Nuclear Information System (INIS)

    Lotte, Ph.; Giannella, R.; Von Hellermann, M.; Kuldkepp, M.; Rachlew, E.; Malaquias, A.; Costley, A.; Walker, C.

    2004-01-01

    The Motional Stark Effect (MSE) diagnostic is now considered as an essential diagnostic for an accurate determination of current profiles in tokamak discharges. It mainly allows a measurement of the direction of the total magnetic field, a very powerful constraint for the determination of the safety factor profile. The realisation of such a diagnostic on ITER implies to face new challenges, because of the bigger size of the machine and of its hard environment. Now, most of the foreseen difficulties have been examined, solutions envisaged, and we propose to review them in this paper. This article is divided into 3 parts: 1) principle of the MSE diagnostic and its feasibility at higher Lorentz electric fields, 2) spatial and time resolution of the diagnostic, and 3) the light collection system

  8. ZEST: A Fast Code for Simulating Zeeman-Stark Line-Shape Functions

    Directory of Open Access Journals (Sweden)

    Franck Gilleron

    2018-03-01

    Full Text Available We present the ZEST code, dedicated to the calculation of line shapes broadened by Zeeman and Stark effects. As concerns the Stark effect, the model is based on the Standard Lineshape Theory in which ions are treated in the quasi-static approximation, whereas the effects of electrons are represented by weak collisions in the framework of a binary collision relaxation theory. A static magnetic field may be taken into account in the radiator Hamiltonian in the dipole approximation, which leads to additional Zeeman splitting patterns. Ion dynamics effects are implemented using the fast Frequency-Fluctuation Model. For fast calculations, the static ion microfield distribution in the plasma is evaluated using analytic fits of Monte-Carlo simulations, which depend only on the ion-ion coupling parameter and the electron-ion screening factor.

  9. The AC Stark Effect, Time-Dependent Born-Oppenheimer Approximation, and Franck-Condon Factors

    CERN Document Server

    Hagedorn, G A; Jilcott, S W

    2005-01-01

    We study the quantum mechanics of a simple molecular system that is subject to a laser pulse. We model the laser pulse by a classical oscillatory electric field, and we employ the Born--Oppenheimer approximation for the molecule. We compute transition amplitudes to leading order in the laser strength. These amplitudes contain Franck--Condon factors that we compute explicitly to leading order in the Born--Oppenheimer parameter. We also correct an erroneous calculation in the mathematical literature on the AC Stark effect for molecular systems.

  10. Multiphoton Rabi oscillations between highly excited Stark states of potassium

    International Nuclear Information System (INIS)

    He Yonglin

    2011-01-01

    We have applied a nonperturbative resonant theory to study the Rabi frequency of microwave multiphoton transitions between two Rydberg states of potassium in a static electric field. The Stark electric dipole moments used to calculate the Rabi frequency are determined by the Stark states' wave functions, which are obtained by the diagonalization method. The frequencies of the Rabi oscillations are in good agreement with either experimental ones or ones calculated by the time-dependent close-coupling method and the Floquet theory. Furthermore, we are able to show that the size of avoided crossings between the (n+2)s and (n,3) states can be predicted from the Stark electric dipole moment and the difference of the two Stark states' energy at a given resonance.

  11. Coherence imaging spectro-polarimetry for magnetic fusion diagnostics

    International Nuclear Information System (INIS)

    Howard, J

    2010-01-01

    This paper presents an overview of developments in imaging spectro-polarimetry for magnetic fusion diagnostics. Using various multiplexing strategies, it is possible to construct optical polarization interferometers that deliver images of underlying physical parameters such as flow speed, temperature (Doppler effect) or magnetic pitch angle (motional Stark and Zeeman effects). This paper also describes and presents first results for a new spatial heterodyne interferometric system used for both Doppler and polarization spectroscopy.

  12. Stark resonances: asymptotics and distributional Borel sum

    International Nuclear Information System (INIS)

    Caliceti, E.; Grecchi, V.; Maioli, M.

    1993-01-01

    We prove that the Stark effect perturbation theory of a class of bound states uniquely determines the position and the width of the resonances by Distributional Borel Sum. In particular the small field asymptotics of the width is uniquely related to the large order asymptotics of the perturbation coefficients. Similar results apply to all the ''resonances'' of the anharmonic and double well oscillators. (orig.)

  13. Stark effect of optical properties of excitons in a quantum nanorod with parabolic confinement

    Energy Technology Data Exchange (ETDEWEB)

    Lyo, S.K., E-mail: sklyo@uci.edu

    2014-01-15

    We study the quantum Stark effect of optical properties of a quasi-one-dimensional quantum rod with parabolic confinement. Interplays between the competing/cooperative forces from confinement, electron–hole (e–h) attraction, and an external field are examined by studying the binding energy, the oscillator strength, and the root-mean-square (RMS) average of the e–h separation in a nonlinear electric field. In a long rod with weak confinement, the e–h interaction dominates over the confinement effect, yielding an abrupt drop of the exciton binding energy, oscillator strength, and a sudden increase of the RMS average e–h separation as the excitons are dissociated at the threshold field as the field increases. The exciton-dissociation transition is gradual in a short rod, where the confinement force dominates over the e–h attraction. We show that a DC field can induce an optically active excited exciton state in a narrow field range, causing a sharp peak in the oscillator strength and a dip in the RMS average of the e–h separation as the field increases. The Stark effects are also investigated as a function of the linear confinement length (i.e., rod length) at fixed fields. -- Highlights: • Study the dependence of optical properties of nanorods on the rod size and field. • Study the interplay between forces of confinement, Coulomb attraction, and field. • A strong field induces an optically active excited state observed in quantum dots.

  14. Supersonic Molecular Beam Optical Stark Spectroscopy of MnH.

    Science.gov (United States)

    Gengler, Jamie; Ma, Tongmei; Harrison, Jeremy; Steimle, Timothy

    2006-03-01

    The large moment of inertia, large magnetic moment, and possible large permanent electric dipole moment of manganese monohydride, MnH, makes it a prime candidate for ultra-cold molecule production via Stark deceleration and magnetic trapping. Here we report the first molecular beam production of MnH and the analysis of the Stark effect in the (0,0) A^7 π -- X^ 7σ^+ band. The sample was prepared by laser ablation of solid Mn in an H2 supersonic expansion. The low rotational temperature (MnH and the analysis of T.D. Varberg, J.A. Gray, R.W. Field, and A.J. Merer, J. Mol. Spec. 156, 296-318 (1992). I.E. Gordon, D.R.T. Appadoo, A. Shayesteh, K.A. Walker, and P.F. Bernath, J. Mol. Spec., 229, 145-149 (2005).

  15. Influence of the ac Stark effect on stimulated hyper-Raman profiles in sodium vapor

    International Nuclear Information System (INIS)

    Moore, M.A.; Garrett, W.R.; Payne, M.G.

    1988-08-01

    When pumping near the two-photon 3d resonance in pure sodium vapor and observing the backward hyper-Raman emission to the 3p substates, an asymmetry in ratios of 3p/sub 1/2/, 3p/sub 3/2/ associated emissions was observed dependent upon the direction of the initial laser detuning from the resonance. It has been determined that this asymmetry can be attributed to the ac Stark effect induced by the hyper-Raman emission itself. 3 refs., 3 figs

  16. Stark broadening measurements of Xe III spectral lines

    International Nuclear Information System (INIS)

    Pelaez, R J; Cirisan, M; Djurovic, S; Aparicio, J A; Mar, S

    2006-01-01

    This work reports measured Stark widths of doubly ionized xenon lines. Pulsed arc was used as a plasma source. Measured electron densities and temperatures were in the ranges of (0.2 - 1.6) x 10 23 m -3 and 18 300-25 500 K, respectively. Stark halfwidths of lines from 6s-6p, 6s-4f and 5d-6p transitions have been measured and compared with available experimental and theoretical data

  17. Utilizing the dynamic stark shift as a probe for dielectric relaxation in photosynthetic reaction centers during charge separation.

    Science.gov (United States)

    Guo, Zhi; Lin, Su; Woodbury, Neal W

    2013-09-26

    In photosynthetic reaction centers, the electric field generated by light-induced charge separation produces electrochromic shifts in the transitions of reaction center pigments. The extent of this Stark shift indirectly reflects the effective field strength at a particular cofactor in the complex. The dynamics of the effective field strength near the two monomeric bacteriochlorophylls (BA and BB) in purple photosynthetic bacterial reaction centers has been explored near physiological temperature by monitoring the time-dependent Stark shift during charge separation (dynamic Stark shift). This dynamic Stark shift was determined through analysis of femtosecond time-resolved absorbance change spectra recorded in wild type reaction centers and in four mutants at position M210. In both wild type and the mutants, the kinetics of the dynamic Stark shift differ from those of electron transfer, though not in the same way. In wild type, the initial electron transfer and the increase in the effective field strength near the active-side monomer bacteriochlorophyll (BA) occur in synchrony, but the two signals diverge on the time scale of electron transfer to the quinone. In contrast, when tyrosine is replaced by aspartic acid at M210, the kinetics of the BA Stark shift and the initial electron transfer differ, but transfer to the quinone coincides with the decay of the Stark shift. This is interpreted in terms of differences in the dynamics of the local dielectric environment between the mutants and the wild type. In wild type, comparison of the Stark shifts associated with BA and BB on the two quasi-symmetric halves of the reaction center structure confirm that the effective dielectric constants near these cofactors are quite different when the reaction center is in the state P(+)QA(-), as previously determined by Steffen et al. at 1.5 K (Steffen, M. A.; et al. Science 1994, 264, 810-816). However, it is not possible to determine from static, low-temperature measurments if the

  18. Runge-Lenz wave packet in multichannel Stark photoionization

    International Nuclear Information System (INIS)

    Texier, F.

    2005-01-01

    In a previous slow photoionization experiment, modulations of ionization rings were manifested for Xe in a constant electric field. The present quantum calculation reveals that the modulation is an effect of the multichannel core scattering and of tunneling waves through the Coulomb-Stark potential barrier: the barrier reduces the number of oscillations that is observed relatively to the number of oscillations of the short range wave functions, and the nonhydrogenic core phase shifts modify the position of the ionization rings. We find a hidden difference, in the ionization process, for two close values of the energy depending on the resonance with the barrier. The ionization intensity is interpreted as a Runge-Lenz wave packet; thus, we can relate the quantum modulation to the classical Coulomb-Stark trajectories. The Runge-Lenz wave packet differs from a usual temporal wave packet because its components are eigenstates of the Runge-Lenz vector z projection and its evolution is not temporal but spatial

  19. Influence of the dynamic Stark effect on long-term frequency stability of a self-oscillating magnetometer with laser-pumped alkali atoms

    Science.gov (United States)

    Baranov, A. A.; Ermak, S. V.; Kulachenkov, N. K.; Petrenko, M. V.; Sagitov, E. A.; Semenov, V. V.

    2017-11-01

    This paper presents the results of investigation Stark shift effect influence on the long-term stability of a dual scheme of quantum magnetometers. Such scheme allows suppressing Stark shift components when a certain pumping light polarization is applied. As a result, long-term stability of a quantum sensor increases. However, when low-frequency (LF) and microwave fields are attached to a single vapor cell a coherence circulation in hyperfine structure of alkali atoms takes place. Physical origin of this effect is associated with the so called “dressed” atom theory, when atom is “dressed” by LF field. It yields in multiphoton absorption and resonance frequency shift. First estimates for this shift based on density matrix evolution formalism are provided in the paper.

  20. Interband optical absorption in the Wannier-Stark ladder under the electron-LO-phonon resonance condition

    International Nuclear Information System (INIS)

    Govorov, A.O.

    1993-08-01

    Interband optical absorption in the Wannier-Stark ladder in the presence of the electron-LO-phonon resonance is investigated theoretically. The electron-LO-phonon resonance occurs when the energy spacing between adjacent Stark-ladder levels coincides with the LO-phonon energy. We propose a model describing the polaron effect in a superlattice. Calculations show that the absorption line shape is strongly modified due to the polaron effect under the electron-LO-phonon resonance condition. We consider optical phenomena in a normal magnetic field that leads to enhancement of polaron effects. (author). 17 refs, 5 figs

  1. Stark width regularities within spectral series of the lithium isoelectronic sequence

    Science.gov (United States)

    Tapalaga, Irinel; Trklja, Nora; Dojčinović, Ivan P.; Purić, Jagoš

    2018-03-01

    Stark width regularities within spectral series of the lithium isoelectronic sequence have been studied in an approach that includes both neutrals and ions. The influence of environmental conditions and certain atomic parameters on the Stark widths of spectral lines has been investigated. This study gives a simple model for the calculation of Stark broadening data for spectral lines within the lithium isoelectronic sequence. The proposed model requires fewer parameters than any other model. The obtained relations were used for predictions of Stark widths for transitions that have not yet been measured or calculated. In the framework of the present research, three algorithms for fast data processing have been made and they enable quality control and provide verification of the theoretically calculated results.

  2. The STARK-B database VAMDC node: a repository for spectral line broadening and shifts due to collisions with charged particles

    Science.gov (United States)

    Sahal-Bréchot, S.; Dimitrijević, M. S.; Moreau, N.; Ben Nessib, N.

    2015-05-01

    Accurate spectroscopic diagnostics and modeling require the knowledge of numerous collisional line profiles. Access to such data via an online database has become indispensable. The STARK-B database is aimed at meeting these needs for widths and shifts of isolated lines of neutral and ionized elements due to electron and ion impacts. This database of the Paris Observatory is a result of scientific cooperation between S Sahal-Bréchot (LERMA) and M S Dimitrijević (AOB). Access to it is free, and it was opened online at the end of 2008. STARK-B is a node of the Virtual Atomic and Molecular Data Centre (VAMDC) and thus complies with VAMDC and Virtual Observatory standards. VAMDC is a European Union-funded collaboration among groups involved in the generation and use of interoperable atomic and molecular data. STARK-B now contains all our semiclassical-perturbation (SCP) calculated data for more than 123 neutral or ionized elements as published in international refereed journals. It is devoted to modeling and spectroscopic diagnostics of stellar atmospheres and envelopes, laboratory plasmas, laser equipment, and technological plasmas. Hence, the range of temperatures and densities covered by the tables is broad and depends on the ionization degree of the radiating atom. The modified semiempirical (MSE) results of calculations have begun to be implemented. In this paper, we highlight the key points of the method and the assumptions used in the calculations, which have lately been revisited. Then we present the database and its recent developments, as well as our ongoing work and our plans for the future.

  3. The STARK-B database VAMDC node: a repository for spectral line broadening and shifts due to collisions with charged particles

    International Nuclear Information System (INIS)

    Sahal-Bréchot, S; Moreau, N; Dimitrijević, M S; Nessib, N Ben

    2015-01-01

    Accurate spectroscopic diagnostics and modeling require the knowledge of numerous collisional line profiles. Access to such data via an online database has become indispensable. The STARK-B database is aimed at meeting these needs for widths and shifts of isolated lines of neutral and ionized elements due to electron and ion impacts. This database of the Paris Observatory is a result of scientific cooperation between S Sahal-Bréchot (LERMA) and M S Dimitrijević (AOB). Access to it is free, and it was opened online at the end of 2008. STARK-B is a node of the Virtual Atomic and Molecular Data Centre (VAMDC) and thus complies with VAMDC and Virtual Observatory standards. VAMDC is a European Union-funded collaboration among groups involved in the generation and use of interoperable atomic and molecular data. STARK-B now contains all our semiclassical-perturbation (SCP) calculated data for more than 123 neutral or ionized elements as published in international refereed journals. It is devoted to modeling and spectroscopic diagnostics of stellar atmospheres and envelopes, laboratory plasmas, laser equipment, and technological plasmas. Hence, the range of temperatures and densities covered by the tables is broad and depends on the ionization degree of the radiating atom. The modified semiempirical (MSE) results of calculations have begun to be implemented. In this paper, we highlight the key points of the method and the assumptions used in the calculations, which have lately been revisited. Then we present the database and its recent developments, as well as our ongoing work and our plans for the future. (paper)

  4. Molecular quantum mechanical gradients within the polarizable embedding approach—Application to the internal vibrational Stark shift of acetophenone

    DEFF Research Database (Denmark)

    List, Nanna Holmgaard; Beerepoot, Maarten; Olsen, Jógvan Magnus Haugaard

    2015-01-01

    for the quantum region, covering (multiconfigurational) self-consistent-field and Kohn–Sham density functional theory. As the first application of the implementation, we consider the internal vibrational Stark effect of the C=O group of acetophenone in different solvents and derive its vibrational linear Stark...

  5. Properties of Linear Entropy in k-Photon Jaynes-Cummings Model with Stark Shift and Kerr-Like Medium

    International Nuclear Information System (INIS)

    Liao Qinghong; Wang Yueyuan; Liu Shutian; Ahmad, Muhammad Ashfaq

    2010-01-01

    The time evolution of the linear entropy of an atom in k-photon Jaynes-Cummings model is investigated taking into consideration Stark shift and Kerr-like medium. The effect of both the Stark shift and Kerr-like medium on the linear entropy is analyzed using a numerical technique for the field initially in coherent state and in even coherent state. The results show that the presence of the Kerr-like medium and Stark shift has an important effect on the properties of the entropy and entanglement. It is also shown that the setting of the initial state plays a significant role in the evolution of the linear entropy and entanglement. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  6. Stark laws and fair market value exceptions: an introduction.

    Science.gov (United States)

    Siebrasse, Paul B

    2007-01-01

    This article will focus on one aspect of complexity in modern healthcare, namely the implications of Stark laws and other fraud and abuse provisions, including anti-kickback statutes and HIPAA. Also, this article explores the prevalence of fair market value as an exception in the Stark laws and discusses the meanings of those exceptions. Finally, the article explores basic approaches to assessing fair market value, including cost, income, and marketing approaches.

  7. Stark broadening parameters and transition probabilities of persistent lines of Tl II

    Science.gov (United States)

    de Andrés-García, I.; Colón, C.; Fernández-Martínez, F.

    2018-05-01

    The presence of singly ionized thallium in the stellar atmosphere of the chemically peculiar star χ Lupi was reported by Leckrone et al. in 1999 by analysis of its stellar spectrum obtained with the Goddard High Resolution Spectrograph (GHRS) on board the Hubble Space Telescope. Atomic data about the spectral line of 1307.50 Å and about the hyperfine components of the spectral lines of 1321.71 Å and 1908.64 Å were taken from different sources and used to analyse the isotopic abundance of thallium II in the star χ Lupi. From their results the authors concluded that the photosphere of the star presents an anomalous isotopic composition of Tl II. A study of the atomic parameters of Tl II and of the broadening by the Stark effect of its spectral lines (and therefore of the possible overlaps of these lines) can help to clarify the conclusions about the spectral abundance of Tl II in different stars. In this paper we present calculated values of the atomic transition probabilities and Stark broadening parameters for 49 spectral lines of Tl II obtained by using the Cowan code including core polarization effects and the Griem semiempirical approach. Theoretical values of radiative lifetimes for 11 levels (eight with experimental values in the bibliography) are calculated and compared with the experimental values in order to test the quality of our results. Theoretical trends of the Stark width and shift parameters versus the temperature for spectral lines of astrophysical interest are displayed. Trends of our calculated Stark width for the isoelectronic sequence Tl II-Pb III-Bi IV are also displayed.

  8. Stark broadening parameter regularities and interpolation and critical evaluation of data for CP star atmospheres research: Stark line shifts

    Science.gov (United States)

    Dimitrijevic, M. S.; Tankosic, D.

    1998-04-01

    In order to find out if regularities and systematic trends found to be apparent among experimental Stark line shifts allow the accurate interpolation of new data and critical evaluation of experimental results, the exceptions to the established regularities are analysed on the basis of critical reviews of experimental data, and reasons for such exceptions are discussed. We found that such exceptions are mostly due to the situations when: (i) the energy gap between atomic energy levels within a supermultiplet is equal or comparable to the energy gap to the nearest perturbing levels; (ii) the most important perturbing level is embedded between the energy levels of the supermultiplet; (iii) the forbidden transitions have influence on Stark line shifts.

  9. Orthogonal Electric Field Measurements near the Green Fluorescent Protein Fluorophore through Stark Effect Spectroscopy and pKa Shifts Provide a Unique Benchmark for Electrostatics Models.

    Science.gov (United States)

    Slocum, Joshua D; First, Jeremy T; Webb, Lauren J

    2017-07-20

    Measurement of the magnitude, direction, and functional importance of electric fields in biomolecules has been a long-standing experimental challenge. pK a shifts of titratable residues have been the most widely implemented measurements of the local electrostatic environment around the labile proton, and experimental data sets of pK a shifts in a variety of systems have been used to test and refine computational prediction capabilities of protein electrostatic fields. A more direct and increasingly popular technique to measure electric fields in proteins is Stark effect spectroscopy, where the change in absorption energy of a chromophore relative to a reference state is related to the change in electric field felt by the chromophore. While there are merits to both of these methods and they are both reporters of local electrostatic environment, they are fundamentally different measurements, and to our knowledge there has been no direct comparison of these two approaches in a single protein. We have recently demonstrated that green fluorescent protein (GFP) is an ideal model system for measuring changes in electric fields in a protein interior caused by amino acid mutations using both electronic and vibrational Stark effect chromophores. Here we report the changes in pK a of the GFP fluorophore in response to the same mutations and show that they are in excellent agreement with Stark effect measurements. This agreement in the results of orthogonal experiments reinforces our confidence in the experimental results of both Stark effect and pK a measurements and provides an excellent target data set to benchmark diverse protein electrostatics calculations. We used this experimental data set to test the pK a prediction ability of the adaptive Poisson-Boltzmann solver (APBS) and found that a simple continuum dielectric model of the GFP interior is insufficient to accurately capture the measured pK a and Stark effect shifts. We discuss some of the limitations of this

  10. Quantum mechanical calculation of electric fields and vibrational Stark shifts at active site of human aldose reductase.

    Science.gov (United States)

    Wang, Xianwei; Zhang, John Z H; He, Xiao

    2015-11-14

    Recent advance in biophysics has made it possible to directly measure site-specific electric field at internal sites of proteins using molecular probes with C = O or C≡N groups in the context of vibrational Stark effect. These measurements directly probe changes of electric field at specific protein sites due to, e.g., mutation and are very useful in protein design. Computational simulation of the Stark effect based on force fields such as AMBER and OPLS, while providing good insight, shows large errors in comparison to experimental measurement due to inherent difficulties associated with point charge based representation of force fields. In this study, quantum mechanical calculation of protein's internal electrostatic properties and vibrational Stark shifts was carried out by using electrostatically embedded generalized molecular fractionation with conjugate caps method. Quantum calculated change of mutation-induced electric field and vibrational Stark shift is reported at the internal probing site of enzyme human aldose reductase. The quantum result is in much better agreement with experimental data than those predicted by force fields, underscoring the deficiency of traditional point charge models describing intra-protein electrostatic properties.

  11. Quantum mechanical calculation of electric fields and vibrational Stark shifts at active site of human aldose reductase

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xianwei [Center for Optics and Optoelectronics Research, College of Science, Zhejiang University of Technology, Hangzhou, Zhejiang 310023 (China); State Key Laboratory of Precision Spectroscopy, Institute of Theoretical and Computational Science, East China Normal University, Shanghai 200062 (China); Zhang, John Z. H.; He, Xiao, E-mail: xiaohe@phy.ecnu.edu.cn [State Key Laboratory of Precision Spectroscopy, Institute of Theoretical and Computational Science, East China Normal University, Shanghai 200062 (China); NYU-ECNU Center for Computational Chemistry at NYU Shanghai, Shanghai 200062 (China)

    2015-11-14

    Recent advance in biophysics has made it possible to directly measure site-specific electric field at internal sites of proteins using molecular probes with C = O or C≡N groups in the context of vibrational Stark effect. These measurements directly probe changes of electric field at specific protein sites due to, e.g., mutation and are very useful in protein design. Computational simulation of the Stark effect based on force fields such as AMBER and OPLS, while providing good insight, shows large errors in comparison to experimental measurement due to inherent difficulties associated with point charge based representation of force fields. In this study, quantum mechanical calculation of protein’s internal electrostatic properties and vibrational Stark shifts was carried out by using electrostatically embedded generalized molecular fractionation with conjugate caps method. Quantum calculated change of mutation-induced electric field and vibrational Stark shift is reported at the internal probing site of enzyme human aldose reductase. The quantum result is in much better agreement with experimental data than those predicted by force fields, underscoring the deficiency of traditional point charge models describing intra-protein electrostatic properties.

  12. Experimental determination of the Stark broadening of Cu I spectral lines in a plasma of a capillary discharge

    International Nuclear Information System (INIS)

    Sandolache, G.; Zoita, V.; Bauchire, M.; Le Menn, E.; Gentils, F.; Fleurier, C.

    2001-01-01

    Copper lines are frequently observed in various types of plasma device and industrial plasmas and then it is desirable to develop methods of plasma diagnostics using the emission spectrum of copper lines. The aim of this work is to create a database for the neutral copper spectral lines directly usable for the diagnostic of plasmas with metal vapors. An experimental device has been developed to create a metal plasma having the required metrological properties to facilitate the spectroscopic measurements. A capillary discharge technique has been used to create a plasma jet representing a radially symmetric light source. The copper-hydrogen plasma jet was produced by the ablation of the capillary wall consisting of a copper-embedded elastomer. The plasma jet was observed side-on using the high-resolution spectrometers equipped with ICCD detectors. The 2D square matrix ICCD detectors have permitted the observation of cross sections of the plasma jet. The high-speed time resolved camera equipped with interference filters has been used to check the cylindrical shape and the homogeneity of the plasma jet. The electron density of the plasma jet was obtained by using the H α spectral line of the hydrogen component plasma. The temperature was determined by applying the relative intensity method to the measured intensities of the neutral copper spectral lines emitted by the plasma jet. The hydrogen and copper lines were broadened principally by the Stark effect. The measured temperatures were about 15,000 K and the electron density of about 2x10 17 cm -3 . The results of the Stark broadening of the neutral cooper concerned particularly the lines 453.9 nm, 465.1 nm, 515.3 nm and 529.2 nm. (authors)

  13. An easy way to determine simultaneously the electron density and temperature in high-pressure plasmas by using Stark broadening

    International Nuclear Information System (INIS)

    Torres, J; Jonkers, J; Sande, M J van de; Mullen, J J A M van der; Gamero, A; Sola, A

    2003-01-01

    This paper discusses the possibility of determining, at the same time, both the electron density and temperature in a discharge produced at atmospheric pressure using the Stark broadening of lines spontaneously emitted by a plasma. This direct method allows us to obtain experimental results that are in good agreement with others previously obtained for the same type of discharge. Its advantages and disadvantages compared to other direct methods of diagnostics, namely Thomson scattering, are also discussed. (rapid communication)

  14. A study of the ac Stark effect in doped photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Haque, I; Singh, Mahi R [Department of Physics and Astronomy, University of Western Ontario, London, ON, N6A 3K7 (Canada)

    2007-04-16

    In this paper we present calculations of level populations and susceptibility for an ensemble of five-level atoms doped in a photonic crystal, using the master equation method. The atoms in the ensemble interact with the crystal which acts as a reservoir and are coupled with two strong pump fields and a weak probe field. It is found that, by manipulating the resonance energy associated with one of the decay channels of the atom, the system can be switched between an inverted and a non-inverted state. We have also observed the ac Stark effect in these atoms and have shown that due to the role played by the band structure of the photonic crystal, it is possible to switch between an absorption state and a non-absorption state of the atomic system. This is a very important finding as techniques of rendering material systems transparent to resonant laser radiation are very desirable in the fabrication of novel optical and photonic devices.

  15. Exceptions to the Stark law: practical considerations for surgeons.

    Science.gov (United States)

    Satiani, Bhagwan

    2006-03-01

    The purpose of this study was to provide an understanding of the applicable legislative exceptions to prohibitions under the Stark law, which governs common legitimate business relationships in surgical practice. Stark I and II prohibits all referrals (and claims) for the provision of designated health services for federal reimbursement if a physician or immediate family member has any financial relationship with the entity. Regardless of intent (unlike the antikickback statute), any financial relationship is illegal unless specifically excepted by statute. These exceptions are relevant to ownership, compensation arrangements, or both. The most important ones relevant to surgeons are as follows: physician service exception (services rendered in an intragroup referral); in-office ancillary services exception (office-based vascular laboratory); the whole hospital exception (ownership interest in a hospital or department); lease exception (conditions that must be met for a lease not to be considered illegal); bona fide employment exception (important to academic medical centers); personal services arrangement exception (vascular laboratory medical directorship); physician incentive plans exception (if volume or value of referrals are an issue); hospital-affiliated group practice exception (physician services billed by a hospital); recruitment arrangement exception (inducements by hospitals to relocate); items/services exception (transcription services purchased from a hospital); fair market value exception (covers services provided to health care entities); indirect compensation arrangements (dealings between a hospital and entity owned by physicians); and academic medical centers exception (new phase II rules broaden the definition of academic medical centers and ease the requirement that practice plans be tax-exempt organizations, among other changes. Although expert legal advice is required for navigation through the maze of Stark laws, it is incumbent on surgeons

  16. On the Application of Stark Broadening Data Determined with a Semiclassical Perturbation Approach

    Directory of Open Access Journals (Sweden)

    Milan S. Dimitrijević

    2014-08-01

    Full Text Available The significance of Stark broadening data for problems in astrophysics, physics, as well as for technological plasmas is discussed and applications of Stark broadening parameters calculated using a semiclassical perturbation method are analyzed.

  17. Motional stark effect upgrades on DIII-D

    International Nuclear Information System (INIS)

    Rice, B.W.; Nilson, D.G.; Wroblewski, D.

    1994-04-01

    The measurement and control of the plasma current density profile (or q profile) is critical to the advanced tokamak program on DIII-D. A complete understanding of the stability and transport properties of advanced operating regimes requires detail poloidal field measurements over the entire plasma radius from the core to the edge. In support of this effort, the authors have recently completed an upgrade of the existing MSE diagnostic, increasing the number of channels from 8 to 16. A new viewing geometry has been added to the outer edge of the plasma which improves the radial resolution in this region from 10 cm to < 4 cm. This view requires the use of a reflector that has been designed to minimize polarization amplitude and phase effects. Vacuum-compatible polarizers have also been added to the instrument for in-situ calibration. Future use of the MSE diagnostic for feedback control of the q profile will also be discussed

  18. Wannier–Stark electro-optical effect, quasi-guided and photonic modes in 2D macroporous silicon structures with SiO_2 coatings

    International Nuclear Information System (INIS)

    Karachevtseva, L.; Goltviansky, Yu.; Sapelnikova, O.; Lytvynenko, O.; Stronska, O.; Bo, Wang; Kartel, M.

    2016-01-01

    Highlights: • The IR absorption spectra of oxidized macroporous silicon were studied. • The Wannier–Stark electro-optical effect on Si-SiO_2 boundary was confirmed. • An additional electric field of quasi-guided optical modes was evaluated. • The photonic modes and band gaps were measured as peculiarities in absorption spectra. - Abstract: Opportunities to enhance the properties of structured surfaces were demonstrated on 2D macroporous silicon structures with SiO_2 coatings. We investigated the IR light absorption oscillations in macroporous silicon structures with SiO2 coatings 0–800 nm thick. The Wannier–Stark electro-optical effect due to strong electric field on Si-SiO_2boundary and an additional electric field of quasi-guided optical modes were taken into account. The photonic modes and band gaps were also considered as peculiarities in absorbance spectra of macroporous silicon structures with a thick SiO_2 coating. The photonic modes do not coincide with the quasi-guided modes in the silicon matrix and do not appear in absorption spectra of 2D macroporous silicon structures with surface nanocrystals.

  19. Measurement of the poloidal magnetic field in the PBX-M tokamak using the motional Stark effect

    International Nuclear Information System (INIS)

    Levinton, F.M.; Fonck, R.J.; Gammel, G.M.; Kaita, R.; Kugel, H.W.; Powell, E.T.; Roberts, D.W.

    1989-05-01

    Polarimetry measurements of the Doppler-shifted H/sub α/ emission from a hydrogen neutral beam on the PBX-M tokamak have been employed in a novel technique for obtaining q(0) and poloidal magnetic field profiles. The electric field from the beam particle motion across the magnetic field (E = V/sub beam/ /times/ B) causes a wavelength splitting of several angstroms, and polarization of the emitted radiation (Stark effect). Viewed transverse to the fields, the emission is linearly polarized with the angle of polarization related to the direction of the magnetic field. 14 refs., 5 figs

  20. Stark widths of Xe II lines in a pulsed plasma

    International Nuclear Information System (INIS)

    Djurovic, S; Pelaez, R J; Cirisan, M; Aparicio, J A; Mar, S

    2006-01-01

    In this paper, we present a review of experimental work on Stark broadening of singly ionized xenon lines. Eighty lines, from close UV to the red region of the spectrum, have been studied. Stark halfwidths were compared with experimental data from the literature and modified semi-empirical calculations. A pulsed arc with 95% of helium and 5% xenon was used as a plasma source for this study. Measured electron densities N e and temperatures T were in the ranges of 0.2-1.6 x 10 23 m -3 and 18 300-25 500 K, respectively

  1. New Aspects of Field Entropy Squeezing as an Indicator for Mixed State Entanglement in an Effective Two-Level System with Stark Shift

    Institute of Scientific and Technical Information of China (English)

    S.Abdel-Khalek; M.M.A.Ahmed; A-S F.Obada

    2011-01-01

    We present an effective two-level system in interaction through two-photon processes with a single mode quantized electromagnetic field,initially prepared in a coherent state.Field entropy squeezing as an indicator of the entanglement in a mixed state system is suggested.The temporal evolution of the negativity,Wehrl entropy,Wehrl phase distribution and field entropy squeezing are investigated.The results highlight the important roles played by both the Stark shift parameters and the mixed state setting in the dynamics of the Wehrl entropy,Wehrl phase distribution and field entropy squeezing.%We present an effective two-level system in interaction through two-photon processes with a single mode quantized electromagnetic Reid, initially prepared in a coherent state. Field entropy squeezing as an indicator of the entanglement in a mixed state system is suggested. The temporal evolution of the negativity, Wehrl entropy, Wehrl phase distribution and field entropy squeezing are investigated. The results highlight the important roles played by both the Stark shift parameters and the mixed state setting in the dynamics of the Wehrl entropy, Wehrl phase distribution and field entropy squeezing.

  2. Stark broadening of several Bi IV spectral lines of astrophysical interest

    Science.gov (United States)

    Colón, C.; Moreno-Díaz, C.; de Andrés-García, I.; Alonso-Medina, A.

    2017-09-01

    The presence of spectral lines of bismuth in stellar atmospheres has been reported in different stars. The anomalous values of the spectral intensities of Bi II and Bi III, compared to the theoretical Local Termodinamic Equilibrium (LTE) standards of Bi I/Bi II/Bi III, have been reported in the spectra obtained with the High Resolution Spectrograph of the Hubble/Goddard Space Telescope in the chemically peculiar stars HgMn stars χ Lupi and HR 7775. Spectral lines of 1436.8, 1902.3, 2630.9 and 2936.7 Å of Bi II and 1423.4 Å of Bi III were reported and their relative intensities were measured in these studies Litzén & Wahlgren 2002. These lines are overlapped with spectral lines of 1437.65, 2630.1 and 2937.1 Å of Bi IV. A study of the Stark broadening parameters of Bi IV spectral lines can help to study these overlaps. In this paper, using the Griem semi-empirical approach, we report calculated values of the Stark parameters for 64 spectral lines of Bi IV. The matrix elements used in these calculations have been determined from 17 configurations of Bi IV. They were calculated using the cowan code including core polarization effects. Data are displayed for an electron density of 1017 cm-3 and temperatures T = 10 000-160 000 K. Also calculated radiative lifetimes for 12 levels with experimental lifetime are presented, in order to test the goodness of our calculations. Theoretical trends of the Stark width and shift parameters versus the temperature for spectral lines of astrophysical interest are displayed.

  3. Position- and time-resolved Stark broadening diagnostics of a non-thermal laser-induced plasma

    International Nuclear Information System (INIS)

    Liu, Hao; Truscott, Benjamin S; Ashfold, Michael N R

    2016-01-01

    We present an analysis of the Stark-broadened line shapes of silicon ions in a laser-induced plasma using a model constructed, without assuming local thermodynamic equilibrium (LTE), using a Druyvesteyn electron energy distribution function (EEDF). The method is applied to temporally and spatially resolved measurements of Si 2+ and Si 3+ emissions from a transient plasma expanding into vacuum, produced by 1064 nm, nanosecond pulsed laser ablation of a Si (1 0 0) target. The best-fitting simulated line shapes and the corresponding electron number densities and temperatures (or equivalently, Druyvesteyn average energies) are compared with those returned assuming LTE (i.e. for a Maxwellian EEDF). Non-thermal behavior is found to dominate at all but the very earliest stages of expansion close to the target surface, consistent with McWhirter’s criterion for the establishment of LTE. The Druyvesteyn EEDF always yields an equivalent or better model of the experimental measurements, and the observed increasingly strong departure from the Maxwellian case with time and distance from the ablation event highlights the essential invalidity of the LTE assumption for moderate-power, nanosecond laser-induced plasma expanding in vacuo. (paper)

  4. Modified dynamic Stark shift and depopulation rate of an atom inside a Kerr nonlinear blackbody

    International Nuclear Information System (INIS)

    Yin Miao; Cheng Ze

    2009-01-01

    We investigate the dynamic Stark shift and atomic depopulation rate induced by real photons in a Kerr nonlinear blackbody. We found that the dynamic Stark shift and atomic depopulation rate are equally modified by a nonlinear contribution factor and a linear contribution factor under a transition temperature T c . The nonlinear contribution factor depends on the Kerr nonlinear coefficient as well as the absolute temperature. Below T c , the absolute values of the dynamic Stark shift and depopulation rate of a single atomic state (not the ground state) are correspondingly larger than those in a normal blackbody whose interior is filled with a nonabsorbing linear medium. Above T c , the dynamic Stark shift and atomic depopulation rate are correspondingly equal to those in a normal blackbody with a nonabsorbing linear medium in its interior.

  5. Existence of the Stark-Wannier quantum resonances

    Energy Technology Data Exchange (ETDEWEB)

    Sacchetti, Andrea, E-mail: andrea.sacchetti@unimore.it [Department of Physics, Computer Sciences and Mathematics, University of Modena e Reggio Emilia, Modena (Italy)

    2014-12-15

    In this paper, we prove the existence of the Stark-Wannier quantum resonances for one-dimensional Schrödinger operators with smooth periodic potential and small external homogeneous electric field. Such a result extends the existence result previously obtained in the case of periodic potentials with a finite number of open gaps.

  6. Asymmetry of Hβ Stark profiles in T-tube hydrogen plasma

    International Nuclear Information System (INIS)

    Djurovic, S.; Nikolic, D.; Savic, I.; Soerge, S.; Demura, A. V.

    2005-01-01

    The whole Balmer H β line profiles are studied in detail experimentally in the T-tube discharge for the wide range of plasma parameters. Besides the common one, two additional parameters are introduced to characterize the asymmetry behavior of the experimental Stark profiles with the reference point chosen in the center of the line. The experimental data are analyzed and benchmarked versus the simple theoretical model based on the effects of microfield nonuniformity and electron impact shifts

  7. A new questionnaire for measuring quality of life - the Stark QoL.

    Science.gov (United States)

    Hardt, Jochen

    2015-10-26

    The Stark questionnaire measures health-related quality of life (QoL) using pictures almost exclusively. It is supplemented by a minimum of words. It comprises a mental and a physical health component. A German sample of n = 500 subjects, age and gender stratified, filled out the Stark Qol questionnaire along with various other questionnaires via internet. The physical component shows good reliability (Cronbach's alpha = McDonalds Omega = greatest lower bound = .93), the mental component can be improved (Cronbach's alpha = .63, McDonalds Omega = .72, greatest lower bound = .77). Confirmatory factor analysis shows a good fit (Bentlers CFI = .97). Construct validity was proven. The Stark QoL is a promising new development in measuring QoL, it is a short and easy to apply questionnaire. Additionally, it is particularly promising for international research.

  8. Stark broadening of Ca IV spectral lines of astrophysical interest

    Science.gov (United States)

    Alonso-Medina, A.; Colón, C.

    2014-12-01

    Ca IV emission lines are under the preview of Solar Ultraviolet Measurements of Emitted Radiation device aboard the Solar and Heliospheric Observatory. Also, lines of the Ca IV in planetary nebulae NGC 7027 were detected with the Short Wavelength Spectrometer on board the Infrared Space Observatory. These facts justify an attempt to provide new spectroscopic parameters of Ca IV. There are no theoretical or experimental Stark broadening data for Ca IV. Using the Griem semi-empirical approach and the COWAN code, we report in this paper calculated values of the Stark broadening parameters for 467 lines of Ca IV. They were calculated using a set of wavefunctions obtained by using Hartree-Fock relativistic calculations. These lines arising from 3s23p4ns (n = 4, 5), 3s23p44p, 3s23p4nd (n = 3, 4) configurations. Stark widths and shifts are presented for an electron density of 1017 cm-3 and temperatures T = 10 000, 20 000 and 50 200 K. As these data cannot be compared to others in the literature, we present an analysis of the different regularities of the values presented in this work.

  9. Observation of the Stark effect in υ+ = 0 Rydberg states of NO: a comparison between predissociating and bound states

    International Nuclear Information System (INIS)

    Jones, N J A; Minns, R S; Patel, R; Fielding, H H

    2008-01-01

    The Stark spectra of Rydberg states of NO below the υ + = 0 ionization limit, with principal quantum numbers n = 25-30, have been investigated in the presence of dc electric fields in the range 0-150 V cm -1 . The Stark states were accessed by two-colour, double-resonance excitation via the υ' = 0, N' = 0 rovibrational state of the A 2 Σ + state. The N( 2 D) atoms produced by predissociation were measured by (2 + 1) resonance-enhanced multiphoton ionization, and compared with pulsed-field ionization spectra of the bound Rydberg state population (Patel et al 2007 J. Phys. B: At. Mol. Opt. Phys. 40 1369)

  10. Phonon-assisted hopping of an electron on a Wannier-Stark ladder in a strong electric field

    International Nuclear Information System (INIS)

    Emin, D.; Hart, C.F.

    1987-01-01

    With the application of a spatially constant electric field, the degeneracy of electronic energy levels of geometrically equivalent sites of a crystal is generally lifted. As a result, the electric field causes the electronic eigenstates of a one-dimensional periodic chain to become localized. In particular, they are Wannier-Stark states. With sufficiently large electric-field strengths these states become sufficiently well localized that it becomes appropriate to consider electronic transport to occur via a succession of phonon-assisted hops between the localized Wannier-Stark states. In this paper, we present calculations of the drift velocity arising from acoustic- and optical-phonon-assisted hopping motion between Wannier-Stark states. When the intersite electronic transfer energy is sufficiently small so that the Wannier-Stark states are essentially each confined to a single atomic site, the transport reduces to that of a small polaron. In this regime, while the drift velocity initially rises with increasing electric field strength, the drift velocity ultimately falls with increasing electric-field strength at extremely large electric fields. More generally, for common values of the electronic bandwidth and electric field strength, the Wannier-Stark states span many sites. At sufficiently large electric fields, the energy separation between Wannier-Stark states exceeds the energy uncertainty associated with the carrier's interaction with phonons. Then, it is appropriate to treat the electronic transport in terms of phonon-assisted hopping between Wannier-Stark states. The resulting high-field drift velocity falls with increasing field strength in a series of steps. Thus, we find a structured negative differential mobility at large electric fields

  11. Stark shift measurements of Xe II and Xe III spectral lines

    International Nuclear Information System (INIS)

    Cirisan, M; Pelaez, R J; Djurovic, S; Aparicio, J A; Mar, S

    2007-01-01

    Stark shift measurements of singly and doubly ionized Xe spectral lines are presented in this paper. Shifts of 110 Xe II lines and 42 Xe III lines are reported, including a significant number of new results. A low-pressure-pulsed arc with 95% of He and 5% of Xe was used as a plasma source. All measurements were performed under the following plasma conditions: electron density (0.2-1.4) x 10 23 m -3 and electron temperature 18 000-23 000 K. The measured Stark shifts are compared with other experimental and theoretical data

  12. Effect of holding period prior to storage on the chemical attributes of Starking Delicious apples during refrigerated storage

    Directory of Open Access Journals (Sweden)

    Aynur Batkan

    2012-06-01

    Full Text Available In this research, the effects of three different holding periods (6, 12 and 24 hours prior to storage on the quality attributes of Starking Delicious apples were investigated during storage of 8 months at 0.5 ± 1.0 ºC. Changes in weight loss, flesh firmness, pH values, soluble dry matter amount, titratable acidity values, ascorbic acid contents, and total and reducing sugar content were determined. According to the results, the holding period showed statistically significant changes in the quality attributes of the apples (p < 0.05.

  13. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade.

    Science.gov (United States)

    Viezzer, E; Dux, R; Dunne, M G

    2016-11-01

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line D α . The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  14. Rydberg-Stark states of Positronium for atom optics

    International Nuclear Information System (INIS)

    Alonso, A M; Cooper, B S; Deller, A; Hogan, S D; Wall, T E; Cassidy, D B

    2015-01-01

    Positronium atoms were produced in Rydberg states by means of a two-step optical excitation process (1s→2p→nd/ns). The n = 11 Rydberg-Stark manifold has been studied using different laser polarizations providing greater control over the electric dipole moment. (paper)

  15. Strong quantum-confined stark effect in germanium quantum-well structures on silicon

    International Nuclear Information System (INIS)

    Kuo, Y.; Lee, Y. K.; Gei, Y.; Ren, S; Roth, J. E.; Miller, D. A.; Harris, J. S.

    2006-01-01

    Silicon is the dominant semiconductor for electronics, but there is now a growing need to integrate such component with optoelectronics for telecommunications and computer interconnections. Silicon-based optical modulators have recently been successfully demonstrated but because the light modulation mechanisms in silicon are relatively weak, long (for example, several millimeters) devices or sophisticated high-quality-factor resonators have been necessary. Thin quantum-well structures made from III-V semiconductors such as GaAs, InP and their alloys exhibit the much stronger Quantum-Confined Stark Effect (QCSE) mechanism, which allows modulator structures with only micrometers of optical path length. Such III-V materials are unfortunately difficult to integrate with silicon electronic devices. Germanium is routinely integrated with silicon in electronics, but previous silicon-germanium structures have also not shown strong modulation effects. Here we report the discovery of the QCSE, at room temperature, in thin germanium quantum-well structures grown on silicon. The QCSE here has strengths comparable to that in III-V materials. Its clarity and strength are particularly surprising because germanium is an indirect gap semiconductor, such semiconductors often display much weak optical effects than direct gap materials (such as the III-V materials typically used for optoelectronics). This discovery is very promising for small, high-speed, low-power optical output devices fully compatible with silicon electronics manufacture. (author)

  16. Stark shift and photoionization cross section of on-center and off-center donor impurity in a core/shell ellipsoidal quantum dot

    Science.gov (United States)

    Shi, L.; Yan, Z. W.

    2018-04-01

    Within the framework of the effective-mass approximation and by using a variational method, the Stark shift of on-center and off-center donor impurity binding energies and photoionization cross section under a z-direction electric field in a prolate (oblate) core/shell ellipsoidal quantum dot has been studied. We have calculated the Stark shift as a function of the core and shell sizes and shapes, electric field, and impurity position. We also discuss the photoionization cross section as a function of photon energy with different core and shell sizes and shapes, electric field strengths, and impurity positions. The results show that the Stark shift depends strongly on the impurity position, it could be positive or negative. The core and shell sizes and shapes also have a pronounce influence on the Stark shift, and the Stark shift changes with them is non-monotonic, especially when the impurity is located at the -z-axis, the situation will become complicated. In addition, the core and shell sizes and shapes, impurity position, and electric field also have an important influence on the photoionization cross section. In particular, the photoionization cross section will vanish when the impurity is located at center of spherical core with spherical or prolate shell case at zero field.

  17. Stark effect of the hyperfine structure of ICl in its rovibronic ground state: Towards further molecular cooling

    Science.gov (United States)

    Qing-Hui, Wang; Xu-Ping, Shao; Xiao-Hua, Yang

    2016-01-01

    Hyperfine structures of ICl in its vibronic ground state due to the nuclear spin and electric quadruple interactions are determined by diagonalizing the effective Hamiltonian matrix. Furthermore, the Stark sub-levels are precisely determined as well. The results are helpful for electro-static manipulation (trapping or further cooling) of cold ICl molecules. For example, an electric field of 1000 V/cm can trap ICl molecules less than 637 μK in the lowest hyperfine level. Project supported by the National Natural Science Foundation of China (Grant No. 11034002), the National Basic Research Program of China (Grant No. 2011CB921602), and Qing Lan Project, China.

  18. Stark effect-dependent of ground-state donor binding energy in InGaN/GaN parabolic QWW

    International Nuclear Information System (INIS)

    El Ghazi, Haddou; Zorkani, Izeddine; Jorio, Anouar

    2013-01-01

    Using the finite-difference method within the quasi-one-dimensional effective potential model and effective mass approximation, the ground-state binding energy of hydrogenic shallow-donor impurity in wurtzite (WZ) (In,Ga)N/GaN parabolic transversal-section quantum-well wires (PQWWs) subjected to external electric field is investigated. An effective radius of a cylindrical QWW describing the strength of the lateral confinement is introduced. The results show that (i) the position of the largest electron probability density in x–y plane is located at a point and it is pushed along the negative sense by the electric field directed along the positive sense, (ii) the ground-state binding energy is largest for the impurity located at this point and starts to decrease when the impurity is away from this point, (iii) the ground-state binding energy decreases with increase in the external electric field and effective radius, and (iv) the Stark-shift increases with the increase of the external electric field and the effective radius

  19. Stark broadening of potassium ns-4p and nd-4p lines in a wall-stabilized arc

    International Nuclear Information System (INIS)

    Hohimer, J.P.

    1984-01-01

    Stark-width measurements are reported for lines in the ns-4p (n = 7--10) and nd-4p (n = 5--8) series in neutral potassium (K I). These measurements were made by observing the end-on emission from a low pressure (20 Torr) potassium-argon wall-stabilized arc source. The on-axis electron density and temperature in the 20-A arc were (2.0 +- 0.2) x 10 15 cm -3 and 2955 +- 100 K, respectively. The experimentally determined Stark widths were compared with the theoretical values calculated by Griem. The measured Stark widths agreed with theory to within 30% for lines in the ns-4p series; while the measured Stark widths of the nd-4p series lines were only one-third of the theoretical values

  20. Simultaneous influence of Stark effect and excessive line broadening on the Hα line

    Science.gov (United States)

    Cvetanović, Nikola; Ivković, Saša S.; Obradović, Bratislav M.; Kuraica, Milorad M.

    2017-12-01

    The aim of this paper is to study the combined influence of the Stark effect and the excessive Doppler broadening on the Balmer alpha line in hydrogen discharges. Since this line is a good candidate for measuring electric field in various types of discharges with different gas compositions, a simple method for field measurement based on polarization spectroscopy is developed, that includes all the excitation mechanisms. To simultaneously test the flexibility of the fitting procedure and investigate the excessive broadening, we applied the fitting procedure on line profiles obtained at a range of conditions from two different discharges. The range of pressures and voltages was examined in an abnormal glow and in dielectric barrier discharge operating with hydrogen gas. The model fitting function was able to respond and follow the change in the line profile caused by the change of conditions. This procedure can therefore be recommended for electric field measurement. Contribution to the "Topical Issue: Physics of Ionized Gases (SPIG 2016)", edited by Goran Poparic, Bratislav Obradovic, Dragana Maric and Aleksandar Milosavljevic.

  1. Stark-shift of impurity fundamental state in a lens shaped quantum dot

    Science.gov (United States)

    Aderras, L.; Bah, A.; Feddi, E.; Dujardin, F.; Duque, C. A.

    2017-05-01

    We calculate the Stark effect and the polarisability of shallow-donor impurity located in the centre of lens shaped quantum dot by a variational method and in the effective-mass approximation. Our theoretical model assumes an infinite confinement to describe the barriers at the dot boundaries and the electric field is considered to be applied in the z-direction. The systematic theoretical investigation contains results with the quantum dot size and the strength of the external field. Our calculations reveal that the interval wherein the polarisability varies depends strongly on the dot size.

  2. Modeling of hydrogen Stark line shapes with kinetic theory methods

    Science.gov (United States)

    Rosato, J.; Capes, H.; Stamm, R.

    2012-12-01

    The unified formalism for Stark line shapes is revisited and extended to non-binary interactions between an emitter and the surrounding perturbers. The accuracy of this theory is examined through comparisons with ab initio numerical simulations.

  3. Theoretical investigation of stark effect on shallow donor binding energy in InGaN spherical QD-QW

    International Nuclear Information System (INIS)

    El Ghazi, Haddou; Jorio, Anouar; Zorkani, Izeddine

    2013-01-01

    In this paper, a simultaneous study of electric field and impurity's position effects on the ground-state shallow-donor binding energy in GaN|InGaN|GaN spherical quantum dot-quantum well (SQD-QW) as a function of the ratio of the inner and the outer radius is reported. The calculations are investigated using variational approach within the framework of the effective-mass approximation. The numerical results show that: (i) the binding energy is strongly affected by the external electric field and the SQD-QW dimension, (ii) a critical value of spherical system's radius is obtained constituting the limit of three dimension confinement and spherical thin layer confinement and (iii) the Stark shift increases with increasing electric field and it is more pronounced around the position of the impurity corresponding to the binding energy maxima than in the spherical layer extremities

  4. Stark Broadening of Carbon and Oxygen Lines in Hot DQ White Dwarf Stars: Recent Results and Applications

    Directory of Open Access Journals (Sweden)

    Dufour P.

    2011-12-01

    Full Text Available White dwarf stars are traditionally found to have surface compositions made primarily of hydrogen or helium. However, a new family has recently been uncovered, the so-called hot DQ white dwarfs, which have surface compositions dominated by carbon and oxygen with little or no trace of hydrogen and helium (Dufour et al. 2007, 2008, 2010. Deriving precise atmospheric parameters for these objects (such as the effective temperature and the surface gravity requires detailed modeling of spectral line profiles. Stark broadening parameters are of crucial importance in that context. We present preliminary results from our new generation of model atmospheres including the latest Stark broadening calculations for C II lines and discuss the implications as well as future work that remains to be done.

  5. Propagation of vector solitons in a quasi-resonant medium with stark deformation of quantum states

    Energy Technology Data Exchange (ETDEWEB)

    Sazonov, S. V., E-mail: sazonov.sergei@gmail.com [National Research Centre Kurchatov Institute (Russian Federation); Ustinov, N. V., E-mail: n_ustinov@mail.ru [Moscow State Railway University, Kaliningrad Branch (Russian Federation)

    2012-11-15

    The nonlinear dynamics of a vector two-component optical pulse propagating in quasi-resonance conditions in a medium of nonsymmetric quantum objects is investigated for Stark splitting of quantum energy levels by an external electric field. We consider the case when the ordinary component of the optical pulse induces {sigma} transitions, while the extraordinary component induces the {pi} transition and shifts the frequencies of the allowed transitions due to the dynamic Stark effect. It is found that under Zakharov-Benney resonance conditions, the propagation of the optical pulse is accompanied by generation of an electromagnetic pulse in the terahertz band and is described by the vector generalization of the nonlinear Yajima-Oikawa system. It is shown that this system (as well as its formal generalization with an arbitrary number of optical components) is integrable by the inverse scattering transformation method. The corresponding Darboux transformations are found for obtaining multisoliton solutions. The influence of transverse effects on the propagation of vector solitons is investigated. The conditions under which transverse dynamics leads to self-focusing (defocusing) of solitons are determined.

  6. Theoretical investigation of stark effect on shallow donor binding energy in InGaN spherical QD-QW

    Energy Technology Data Exchange (ETDEWEB)

    El Ghazi, Haddou, E-mail: hadghazi@gmail.com [Solid State Physics Laboratory, Faculty of Science, Dhar EL Mehrez, BP 1796 Fes-Atlas (Morocco); Mathématiques spéciales, CPGE Kénitra, Chakib Arsalane Street (Morocco); Jorio, Anouar; Zorkani, Izeddine [Solid State Physics Laboratory, Faculty of Science, Dhar EL Mehrez, BP 1796 Fes-Atlas (Morocco)

    2013-08-01

    In this paper, a simultaneous study of electric field and impurity's position effects on the ground-state shallow-donor binding energy in GaN|InGaN|GaN spherical quantum dot-quantum well (SQD-QW) as a function of the ratio of the inner and the outer radius is reported. The calculations are investigated using variational approach within the framework of the effective-mass approximation. The numerical results show that: (i) the binding energy is strongly affected by the external electric field and the SQD-QW dimension, (ii) a critical value of spherical system's radius is obtained constituting the limit of three dimension confinement and spherical thin layer confinement and (iii) the Stark shift increases with increasing electric field and it is more pronounced around the position of the impurity corresponding to the binding energy maxima than in the spherical layer extremities.

  7. Fractional Stark state selective electric field ionization of very high-n Rydberg states of molecules

    International Nuclear Information System (INIS)

    Dietrich, H.; Mueller-Dethlefs, K.; Baranov, L.Y.

    1996-01-01

    For the first time fractional Stark state selective electric field ionization of very high-n (n approx-gt 250) molecular Rydberg states is observed. An open-quote open-quote offset close-quote close-quote electric pulse selectively ionizes the more fragile open-quote open-quote red close-quote close-quote (down shifted in energy) Stark states. The more resilient open-quote open-quote bluer close-quote close-quote, or up-shifted, ones survive and are shifted down in energy upon application of a second (open-quote open-quote probe close-quote close-quote) pulse of opposite direction (diabatic Stark states close-quote inversion). Hence, even for smaller probe than offset fields ionization is observed. The offset/probe ratio allows one to control spectral peak shapes in zero-kinetic-energy photoelectron spectroscopy. copyright 1995 The American Physical Society

  8. A New Analysis of Stark and Zeeman Effects on Hydrogen Lines in Magnetized DA White Dwarfs

    Directory of Open Access Journals (Sweden)

    Ny Kieu

    2017-11-01

    Full Text Available White dwarfs with magnetic field strengths larger than 10 T are understood to represent more than 10% of the total population of white dwarfs. The presence of such strong magnetic fields is clearly indicated by the Zeeman triplet structure visible on absorption lines. In this work, we discuss the line broadening mechanisms and focus on the sensitivity of hydrogen lines on the magnetic field. We perform new calculations in conditions relevant to magnetized DA stellar atmospheres using models inspired from magnetic fusion plasma spectroscopy. A white dwarf spectrum from the Sloan Digital Sky Survey (SDSS database is analyzed. An effective temperature is provided by an adjustment of the background radiation with a Planck function, and the magnetic field is inferred from absorption lines presenting a Zeeman triplet structure. An order-of-magnitude estimate for the electron density is also performed from Stark broadening analysis.

  9. Stark-shift induced resonances in multiphoton ionization

    International Nuclear Information System (INIS)

    Potvliege, R M; Vuci, Svetlana

    2006-01-01

    The resonance enhancements marking the ATI spectrum of argon are discussed in the light of a recently compiled map of the quasienergies of this atom. Many of the dressed excited states of interest shift nonponderomotively in complicated ways, but keep an ionization width narrow enough to produce sharp substructures of both low and high ATI peaks through Stark-shift induced resonances. The most prominent enhancement observed in the high-order ATI peaks originates from ionization from the dressed ground state perturbed by the influence of neighbouring resonant dressed states

  10. Stark interaction of identical particles with the vacuum electromagnetic field as quantum Poisson process suppressing collective spontaneous emission

    International Nuclear Information System (INIS)

    Basharov, A. M.

    2011-01-01

    The effective Hamiltonian describing resonant interaction of an ensemble of identical quantum particles with a photon-free vacuum electromagnetic field has been obtained with allowance for terms of second order in the coupling constant (the Stark interaction) by means of the perturbation theory on the basis of the unitary transformation of the system quantum state. It has been shown that in the Markov approximation the effective Hamiltonian terms of first order in the coupling constant are represented by the quantum Wiener process, whereas terms of second order are expressed by the quantum Poisson process. During the course of the investigation, it was established that the Stark interaction played a significant role in the ensemble dynamics, thus influencing the collective spontaneous decay of the ensemble of an appreciably high number of identical particles. Fundamental effects have been discovered, i.e., the excitation conservation in a sufficiently dense ensemble of identical particles and superradiance suppression in the collective decaying process of an excited ensemble with a determined number of particles.

  11. Comparison of three Stark problem solution techniques for the bounded case

    Science.gov (United States)

    Hatten, Noble; Russell, Ryan P.

    2015-01-01

    Three methods of obtaining solutions to the Stark problem—one developed by Lantoine and Russell using Jacobi elliptic and related functions, one developed by Biscani and Izzo using Weierstrass elliptic and related functions, and one developed by Pellegrini, Russell, and Vittaldev using and Taylor series extended to the Stark problem—are compared qualitatively and quantitatively for the bounded motion case. For consistency with existing available code for the series solution, Fortran routines of the Lantoine method and Biscani method are newly implemented and made available. For these implementations, the Lantoine formulation is found to be more efficient than the Biscani formulation in the propagation of a single trajectory segment. However, for applications for which acceptable accuracy may be achieved by orders up to 16, the Pellegrini series solution is shown to be more efficient than either analytical method. The three methods are also compared in the propagation of sequentially connected trajectory segments in a low-thrust orbital transfer maneuver. Separate tests are conducted for discretizations between 8 and 96 segments per orbit. For the series solution, the interaction between order and step size leads to computation times that are nearly invariable to discretization for a given truncation error tolerance over the tested range of discretizations. This finding makes the series solution particularly attractive for mission design applications where problems may require both coarse and fine discretizations. Example applications include the modeling of low-thrust propulsion and time-varying perturbations—problems for which the efficient propagation of relatively short Stark segments is paramount because the disturbing acceleration generally varies continuously.

  12. Surface Acoustic Bloch Oscillations, the Wannier-Stark Ladder, and Landau-Zener Tunneling in a Solid

    Science.gov (United States)

    de Lima, M. M., Jr.; Kosevich, Yu. A.; Santos, P. V.; Cantarero, A.

    2010-04-01

    We present the experimental observation of Bloch oscillations, the Wannier-Stark ladder, and Landau-Zener tunneling of surface acoustic waves in perturbed grating structures on a solid substrate. A model providing a quantitative description of our experimental observations, including multiple Landau-Zener transitions of the anticrossed surface acoustic Wannier-Stark states, is developed. The use of a planar geometry for the realization of the Bloch oscillations and Landau-Zener tunneling allows a direct access to the elastic field distribution. The vertical surface displacement has been measured by interferometry.

  13. Determination of Stark parameters by cross-calibration in a multi-element laser-induced plasma

    Science.gov (United States)

    Liu, Hao; Truscott, Benjamin S.; Ashfold, Michael N. R.

    2016-05-01

    We illustrate a Stark broadening analysis of the electron density Ne and temperature Te in a laser-induced plasma (LIP), using a model free of assumptions regarding local thermodynamic equilibrium (LTE). The method relies on Stark parameters determined also without assuming LTE, which are often unknown and unavailable in the literature. Here, we demonstrate that the necessary values can be obtained in situ by cross-calibration between the spectral lines of different charge states, and even different elements, given determinations of Ne and Te based on appropriate parameters for at least one observed transition. This approach enables essentially free choice between species on which to base the analysis, extending the range over which these properties can be measured and giving improved access to low-density plasmas out of LTE. Because of the availability of suitable tabulated values for several charge states of both Si and C, the example of a SiC LIP is taken to illustrate the consistency and accuracy of the procedure. The cross-calibrated Stark parameters are at least as reliable as values obtained by other means, offering a straightforward route to extending the literature in this area.

  14. Developmental characters of Pseitina iijimae (Jordan and Starks), bothid flat fishes- pisces

    Digital Repository Service at National Institute of Oceanography (India)

    Devi, C.B.L.

    Post larval stages of Psettina iQimae (Jordan and Starks) ranging from 1.8 mm NL to 44.6 mm SL collected during Naga Expedition and International Indian Ocean Expedition (JIOE) are described The characteristics which help to identify larval stages...

  15. A Riemann-Hilbert approach to the inverse problem for the Stark operator on the line

    Science.gov (United States)

    Its, A.; Sukhanov, V.

    2016-05-01

    The paper is concerned with the inverse scattering problem for the Stark operator on the line with a potential from the Schwartz class. In our study of the inverse problem, we use the Riemann-Hilbert formalism. This allows us to overcome the principal technical difficulties which arise in the more traditional approaches based on the Gel’fand-Levitan-Marchenko equations, and indeed solve the problem. We also produce a complete description of the relevant scattering data (which have not been obtained in the previous works on the Stark operator) and establish the bijection between the Schwartz class potentials and the scattering data.

  16. Effect of holding period prior to storage on the chemical attributes of Starking Delicious apples during refrigerated storage Efeito do período que antecede o armazenamento nos atributos químicos de maças Starking Delicious durante o armazenamento refrigerado

    Directory of Open Access Journals (Sweden)

    Aynur Batkan

    2012-06-01

    Full Text Available In this research, the effects of three different holding periods (6, 12 and 24 hours prior to storage on the quality attributes of Starking Delicious apples were investigated during storage of 8 months at 0.5 ± 1.0 ºC. Changes in weight loss, flesh firmness, pH values, soluble dry matter amount, titratable acidity values, ascorbic acid contents, and total and reducing sugar content were determined. According to the results, the holding period showed statistically significant changes in the quality attributes of the apples (p Neste trabalho, os efeitos de três diferentes tempos de espera (6, 12 e 24 horas antes do armazenamento sobre os atributos de qualidade de maçãs tipo Starking Delicious foram investigados durante o armazenamento de 8 meses a 0,5 ± 1,0 ºC. Alterações na perda de peso, firmeza da polpa, valores de pH, quantidade de matéria seca solúvel, valores de acidez titulável, teor de ácido ascórbico e teor de açúcar redutor e total das amostras foram determinadas. De acordo com os resultados da análise, o tempo de espera causou alterações estatisticamente significativas sobre as nos atributos de qualidade das maçãs (p < 0,05.

  17. Surface Acoustic Analog of Bloch Oscillations, Wannier-Stark Ladders and Landau-Zener Tunneling

    Science.gov (United States)

    de Lima, M. M.; Kosevich, Yu. A.; Santos, P. V.; Cantarero, A.

    2011-12-01

    In this contribution, we discuss the recent experimental demonstration of Wannier-Stark ladders, Bloch Oscillations and Landau Zener tunneling in a solid by means of surface acoustic waves propagating through perturbed grating structures.

  18. Measured, calculated and predicted Stark widths of the singly ionized C, N, O, F, Ne, Si, P, S, Cl and Ar spectral lines

    Directory of Open Access Journals (Sweden)

    Djeniže S.

    2000-01-01

    Full Text Available In order to find reliable Stark width data, needed in plasma spectroscopy comparision between the existing measured, calculated and predicted Stark width values was performed for ten singly ionized emitters: C, N, O, F, Ne Si, P, S, Cl and Ar in the lower lying 3s - 3p, 3p - 3d and 4s - 4p transitions. These emitters are present in many cosmic light sources. On the basis of the agreement between mentioned values 17 spectral lines from six singly ionized spectra have been recommended, for the first time, for plasma spectroscopy as spectral lines with reliable Stark width data. Critical analysis of the existing Stark width data is also given.

  19. Comparison between different methods of magnetic field diagnostics in beam emission spectroscopy

    International Nuclear Information System (INIS)

    Voslamber, D.

    1995-01-01

    Magnetic field diagnostics in tokamaks using the motional Stark effect in fast neutral beams have been based on two kinds of polarimetry which are called 'static' and 'dynamic'. It is shown that static polarimetry presents a number of advantages over dynamic polarimetry, provided it is made complete in the sense that a sufficient number of polarisation analysers is installed and different parts of the spectrum are explored to yield full information on the set of unknowns inherent in the problem. A detailed scheme of self-calibrating static polarimetry is proposed, including the case where an in-vessel mirror with changing characteristics (coating by impurities) is placed in front of the optical detection system. (author) 5 refs.; 2 figs

  20. Can the Stark-Einstein law resolve the measurement problem from an animate perspective?

    Science.gov (United States)

    Thaheld, Fred H

    2015-09-01

    Analysis of the Stark-Einstein law as it applies to the retinal molecule, which is part of the rhodopsin molecule within the rod cells of the retina, reveals that it may provide the solution to the measurement problem from an animate perspective. That it represents a natural boundary where the Schrödinger equation or wave function automatically goes from linear to nonlinear while remaining in a deterministic state. It will be possible in the near future to subject this theory to empirical tests as has been previously proposed. This analysis provides a contrast to the many decades well studied and debated inanimate measurement problem and would represent an addition to the Stark-Einstein law involving information carried by the photon. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Stark broadening of resonant Cr II 3d5-3d44p spectral lines in hot stellar atmospheres

    Science.gov (United States)

    Simić, Z.; Dimitrijević, M. S.; Sahal-Bréchot, S.

    2013-07-01

    New Stark broadening parameters of interest for the astrophysical, laboratory and technological plasma modelling, investigations and analysis for nine resonant Cr II multiplets have been determined within the semiclassical perturbation approach. In order to demonstrate one possibility for their usage in astrophysical plasma research, obtained results have been applied to the analysis of the Stark broadening influence on stellar spectral line shapes.

  2. Stark mapping of H2 Rydberg states in the strong-field regime with dynamical resolution

    International Nuclear Information System (INIS)

    Glab, W.L.; Qin, K.

    1993-01-01

    We have acquired spectra of high Rydberg states of molecular hydrogen in a static external field, in the energy region from below the energy at which field ionization becomes classically possible (E c ) to well above this energy. Simultaneous spectra of ionization and dissociation were acquired, thereby allowing direct information on the excited-state decay dynamics to be obtained. We have found that states with energies below E c undergo field-induced predissociation, while states with energies well above E c decay predominantly by field ionization. Field ionization and dissociation compete effectively as decay channels for states with energies in a restricted region just above E c . Comparison of our ionization spectra to the results of a single-channel quantum-defect theory Stark calculation shows quantitative agreement except near curve crossings, indicating that inclusion of different core rotational state channels will be required to properly account for coupling between the Stark states. Several states in the spectra undergo pronounced changes in their dynamical properties over a narrow range of field values, which we interpret as being due to interference cancellation of the ionization rates for these states

  3. Quantum-confined Stark effect at 1.3 μm in Ge/Si(0.35)Ge(0.65) quantum-well structure.

    Science.gov (United States)

    Rouifed, Mohamed Said; Chaisakul, Papichaya; Marris-Morini, Delphine; Frigerio, Jacopo; Isella, Giovanni; Chrastina, Daniel; Edmond, Samson; Le Roux, Xavier; Coudevylle, Jean-René; Vivien, Laurent

    2012-10-01

    Room-temperature quantum-confined Stark effect in a Ge/SiGe quantum-well structure is reported at the wavelength of 1.3 μm. The operating wavelength is tuned by the use of strain engineering. Low-energy plasma-enhanced chemical vapor deposition is used to grow 20 periods of strain-compensated quantum wells (8 nm Ge well and 12 nm Si(0.35)Ge(0.65) barrier) on Si(0.21)Ge(0.79) virtual substrate. The fraction of light absorbed per well allows for a strong modulation around 1.3 μm. The half-width at half-maximum of the excitonic peak of only 12 meV allows for a discussion on physical mechanisms limiting the performances of such devices.

  4. Stark broadening of the Hα line of hydrogen at low densities: quantal and semiclassical results

    International Nuclear Information System (INIS)

    Stehle, C.; Feautrier, N.

    1984-01-01

    Stark profiles of the Hα lines of hydrogen are computed at low densities in the 'impact' theory. By a comparison with quantal results, it is shown that a simple semiclassical perturbational approach with appropriate cutoffs is sufficient to give accurate profiles in the line centre. Neglecting the natural broadening and the fine-structure effects, the authors prove that the electronic broadening is negligible and that the profile has a Lorentzian shape. An analytical expression of the half width is given. (author)

  5. Science Translator: An Interview with Louisa Stark.

    Science.gov (United States)

    Stark, Louisa A

    2015-07-01

    The Genetics Society of America's Elizabeth W. Jones Award for Excellence in Education recognizes significant and sustained impact on genetics education. The 2015 awardee, Louisa Stark, has made a major impact on global access to genetics education through her work as director of the University of Utah Genetic Science Learning Center. The Center's Learn.Genetics and Teach.Genetics websites are the most widely used online genetic education resources in the world. In 2014, they were visited by 18 million students, educators, scientists, and members of the public. With over 60 million page views annually, Learn.Genetics is among the most used sites on the Web. Copyright © 2015 by the Genetics Society of America.

  6. Influence of Doppler and 'Stark' effects on the shape of the autoionization peaks in electron energy spectra produced in ion-atom collisions

    International Nuclear Information System (INIS)

    Gleizes, A.; Benoit-Cattin, P.; Bordenave-Montesquieu, A.; Merchez, H.

    1976-01-01

    A detailed study is given of the influence of the Doppler shift and broadening on the spectra of electrons ejected by autoionization in collisions between heavy particles. General formulae have been obtained which permit the validity of results already published by other authors to be discussed. These results have been applied to the spectra of electrons ejected in He + -He collisions at 15 keV. The variation of the width of the autoionization peaks against ejection angle is well explained by Doppler broadening. On the contrary, the shape of these peaks cannot be due to the Doppler effect but rather to the Stark effect which is also studied in various experimental cases; it has been verified that the latter effect disappears in collisions between neutral particles for which symmetric peaks at 15 keV are obtained. (author)

  7. High-frequency Stark effect and two-quantum transitions

    International Nuclear Information System (INIS)

    Hildebrandt, J

    2007-01-01

    A problem which motivated a great deal of work about 20 years ago, namely, satellite lines occurring for atomic emitters undergoing a harmonic perturbation, is revisited. On a theoretical point of view, two photon mechanisms or equivalent are involved to explain those satellites due to high-frequency electric fields. Although today the activity on these problems is rather low, interest in observing such effects in the domain of x-ray spectroscopy exists, namely for hot and dense plasmas. More generally, satellites can be also seen as connected to turbulence diagnostics. This mainly motivates the design of plasmas and improvements of x-ray spectroscopy techniques. However, up to now, attempts to extend the methods of nonlinear spectroscopy to this domain have been rather disappointing. As a promotion for a resurgence of the field, an improved theory, founded on formalisms of nonlinear optics, is developed to suggest a new interpretation of the experiments. Previous publications are modified and an old problem is closed. Hopefully, this will help us to stimulate new applications of two-photon techniques in plasmas

  8. Self-screening of the quantum confined Stark effect by the polarization induced bulk charges in the quantum barriers

    International Nuclear Information System (INIS)

    Zhang, Zi-Hui; Liu, Wei; Ju, Zhengang; Tiam Tan, Swee; Ji, Yun; Kyaw, Zabu; Zhang, Xueliang; Wang, Liancheng; Wei Sun, Xiao; Volkan Demir, Hilmi

    2014-01-01

    InGaN/GaN light-emitting diodes (LEDs) grown along the polar orientations significantly suffer from the quantum confined Stark effect (QCSE) caused by the strong polarization induced electric field in the quantum wells, which is a fundamental problem intrinsic to the III-nitrides. Here, we show that the QCSE is self-screened by the polarization induced bulk charges enabled by designing quantum barriers. The InN composition of the InGaN quantum barrier graded along the growth orientation opportunely generates the polarization induced bulk charges in the quantum barrier, which well compensate the polarization induced interface charges, thus avoiding the electric field in the quantum wells. Consequently, the optical output power and the external quantum efficiency are substantially improved for the LEDs. The ability to self-screen the QCSE using polarization induced bulk charges opens up new possibilities for device engineering of III-nitrides not only in LEDs but also in other optoelectronic devices.

  9. Self-screening of the quantum confined Stark effect by the polarization induced bulk charges in the quantum barriers

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zi-Hui; Liu, Wei; Ju, Zhengang; Tiam Tan, Swee; Ji, Yun; Kyaw, Zabu; Zhang, Xueliang; Wang, Liancheng; Wei Sun, Xiao, E-mail: exwsun@ntu.edu.sg, E-mail: volkan@stanfordalumni.org [LUMINOUS Centre of Excellence for Semiconductor Lighting and Displays, School of Electrical and Electronic Engineering, School of Physical and Mathematical Sciences, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Volkan Demir, Hilmi, E-mail: exwsun@ntu.edu.sg, E-mail: volkan@stanfordalumni.org [LUMINOUS Centre of Excellence for Semiconductor Lighting and Displays, School of Electrical and Electronic Engineering, School of Physical and Mathematical Sciences, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Department of Electrical and Electronics, Department of Physics, and UNAM-Institute of Material Science and Nanotechnology, Bilkent University, TR-06800 Ankara (Turkey)

    2014-06-16

    InGaN/GaN light-emitting diodes (LEDs) grown along the polar orientations significantly suffer from the quantum confined Stark effect (QCSE) caused by the strong polarization induced electric field in the quantum wells, which is a fundamental problem intrinsic to the III-nitrides. Here, we show that the QCSE is self-screened by the polarization induced bulk charges enabled by designing quantum barriers. The InN composition of the InGaN quantum barrier graded along the growth orientation opportunely generates the polarization induced bulk charges in the quantum barrier, which well compensate the polarization induced interface charges, thus avoiding the electric field in the quantum wells. Consequently, the optical output power and the external quantum efficiency are substantially improved for the LEDs. The ability to self-screen the QCSE using polarization induced bulk charges opens up new possibilities for device engineering of III-nitrides not only in LEDs but also in other optoelectronic devices.

  10. Stark components of lower-lying manifolds and emission cross-sections of intermanifold and inter-stark transitions of Nd3+(4f3) in polycrystalline ceramic garnet Y3Al5O12

    International Nuclear Information System (INIS)

    Sardar, Dhiraj K.; Yow, Raylon M.; Gruber, John B.; Allik, Toomas H.; Zandi, Bahram

    2006-01-01

    Stark energy levels of the 4 F 3/2 , 4 I 9/2 , and 4 I 11/2 manifolds have been characterized using the room temperature fluorescence spectra for the 4 F 3/2 → 4 I 9/2 and 4 F 3/2 → 4 I 11/2 transitions of Nd 3+ (4f 3 ) in polycrystalline ceramic garnet Y 3 Al 5 O 12 (YAG). The emission cross-sections of the intermanifold transitions, 4 F 3/2 → 4 I 9/2 and 4 F 3/2 → 4 I 11/2 , as well as the principal inter-Stark transitions, R 1 →Z 5 (945.3 nm) and R 1 →Y 2 (1063.5 nm), have also been determined. These results are finally compared with those of Nd 3+ :YAG single crystal

  11. Raman-laser spectroscopy of Wannier-Stark states

    International Nuclear Information System (INIS)

    Tackmann, G.; Pelle, B.; Hilico, A.; Beaufils, Q.; Pereira dos Santos, F.

    2011-01-01

    Raman lasers are used as a spectroscopic probe of the state of atoms confined in a shallow one-dimensional (1D) vertical lattice. For sufficiently long laser pulses, resolved transitions in the bottom band of the lattice between Wannier Stark states corresponding to neighboring wells are observed. Couplings between such states are measured as a function of the lattice laser intensity and compared to theoretical predictions, from which the lattice depth can be extracted. Limits to the linewidth of these transitions are investigated. Transitions to higher bands can also be induced, as well as between transverse states for tilted Raman beams. All these features allow for a precise characterization of the trapping potential and for an efficient control of the atomic external degrees of freedom.

  12. Implementation of quantum logic gates via Stark-tuned Förster resonance in Rydberg atoms

    Science.gov (United States)

    Huang, Xi-Rong; Hu, Chang-Sheng; Shen, Li-Tuo; Yang, Zhen-Biao; Wu, Huai-Zhi

    2018-02-01

    We present a scheme for implementation of controlled-Z and controlled-NOT gates via rapid adiabatic passage and Stark-tuned Förster resonance. By sweeping the Förster resonance once without passing through it and adiabatically tuning the angle-dependent Rydberg-Rydberg interaction of the dipolar nature, the system can be effectively described by a two-level system with the adiabatic theorem. The single adiabatic passage leads to a gate fidelity as high as 0.999 and a greatly reduced gate operation time. We investigate the scheme by considering an actual atomic level configuration with rubidium atoms, where the fidelity of the controlled-Z gate is still higher than 0.99 under the influence of the Zeeman effect.

  13. Diagnostics for real-time plasma control in PBX-M

    Science.gov (United States)

    Kaita, R.; Batha, S.; Bell, R. E.; Bernabei, S.; Hatcher, R.; Kozub, T.; Kugel, H.; Levinton, F.; Okabayashi, M.; Sesnic, S.; von Goeler, S.; Zolfaghari, A.; PBX-M Group

    1995-01-01

    An important issue for future tokamaks is real-time plasma control for the avoidance of magnetohydrodynamic instabilities and other applications that require detailed plasma profile and fluctuation data. Although measurements from diagnostics providing this information require significantly more processing than magnetic flux data, recent advancements could make them practical for adjusting operational settings for plasma heating and current drive systems as well as field coil currents. On the Princeton Beta Experiment-Modification (PBX-M), the lower hybrid current drive phasing can be varied during a plasma shot using digitally programmable ferrite phase shifters, and neural beam functions can be fully computer controlled. PBX-M diagnostics that may be used for control purposes include motional Stark-effect polarimetry for magnetic field pitch angle profiles, soft x-ray arrays for plasma position control and the separation of βp from li, hard x-ray detectors for energetic electron distributions, a multichannel electron cyclotron emission radiometer for ballooning mode identification, and passive plate eddy current monitors for kink stabilization. We will describe the present status of these systems on PBX-M, and discuss their suitability for feedback applications.

  14. Diagnostics for real-time plasma control in PBX-M

    International Nuclear Information System (INIS)

    Kaita, R.; Batha, S.; Bell, R.E.; Bernabei, S.; Hatcher, R.; Kozub, T.; Kugel, H.; Levinton, F.; Okabayashi, M.; Sesnic, S.; Goeler, S. von; Zolfaghari, A.

    1995-01-01

    An important issue for future tokamaks is real-time plasma control for the avoidance of magnetohydrodynamic instabilities and other applications that require detailed plasma profile and fluctuation data. Although measurements from diagnostics providing this information require significantly more processing than magnetic flux data, recent advancements could make them practical for adjusting operational settings for plasma heating and current drive systems as well as field coil currents. On the Princeton Beta Experiment-Modification (PBX-M), the lower hybrid current drive phasing can be varied during a plasma shot using digitally programmable ferrite phase shifters, and neural beam functions can be fully computer controlled. PBX-M diagnostics that may be used for control purposes include motional Stark-effect polarimetry for magnetic field pitch angle profiles, soft x-ray arrays for plasma position control and the separation of β p from l i , hard x-ray detectors for energetic electron distributions, a multichannel electron cyclotron emission radiometer for ballooning mode identification, and passive plate eddy current monitors for kink stabilization. We will describe the present status of these systems on PBX-M, and discuss their suitability for feedback applications

  15. Optimal beam sources for Stark decelerators in collision experiments: a tutorial review

    International Nuclear Information System (INIS)

    Vogels, Sjoerd N.; Gao, Zhi; Meerakker, Sebastiaan Y.T. van de

    2015-01-01

    With the Stark deceleration technique, packets of molecules with a tunable velocity, a narrow velocity spread, and a high state purity can be produced. These tamed molecular beams find applications in high resolution spectroscopy, cold molecule trapping, and controlled scattering experiments. The quality and purity of the packets of molecules emerging from the decelerator critically depend on the specifications of the decelerator, but also on the characteristics of the molecular beam pulse with which the decelerator is loaded. We consider three frequently used molecular beam sources, and discuss their suitability for molecular beam deceleration experiments, in particular with the application in crossed beam scattering in mind. The performance of two valves in particular, the Nijmegen Pulsed Valve and the Jordan Valve, is illustrated by decelerating ND 3 molecules in a 2.6 meter-long Stark decelerator. We describe a protocol to characterize the valve, and to optimally load the pulse of molecules into the decelerator. We characterize the valves regarding opening time duration, optimal valve-to-skimmer distance, mean velocity, velocity spread, state purity, and relative intensity. (orig.)

  16. Wave-function analysis of dynamic cancellation of ac Stark shifts in optical lattice clocks by use of pulsed Raman and electromagnetically-induced-transparency techniques

    International Nuclear Information System (INIS)

    Yoon, Tai Hyun

    2007-01-01

    We study analytically the dynamic cancellation of ac Stark shift in the recently proposed pulsed electromagnetically-induced-transparency (EIT-)Raman optical lattice clock based on the wave-function formalism. An explicit expression for the time evolution operator corresponding to the effective two-level interaction Hamiltonian has been obtained in order to explain the atomic phase shift cancellation due to the ac Stark shift induced by the time-separated laser pulses. We present how to determine an optimum value of the common detuning of the driving fields at which the atomic phase shift cancels completely with the parameters for the practical realization of the EIT-Raman optical lattice clock with alkaline-earth-metal atoms

  17. Molecular quantum mechanical gradients within the polarizable embedding approach—Application to the internal vibrational Stark shift of acetophenone

    International Nuclear Information System (INIS)

    List, Nanna Holmgaard; Jensen, Hans Jørgen Aagaard; Kongsted, Jacob; Beerepoot, Maarten T. P.; Gao, Bin; Ruud, Kenneth; Olsen, Jógvan Magnus Haugaard

    2015-01-01

    We present an implementation of analytical quantum mechanical molecular gradients within the polarizable embedding (PE) model to allow for efficient geometry optimizations and vibrational analysis of molecules embedded in large, geometrically frozen environments. We consider a variational ansatz for the quantum region, covering (multiconfigurational) self-consistent-field and Kohn–Sham density functional theory. As the first application of the implementation, we consider the internal vibrational Stark effect of the C=O group of acetophenone in different solvents and derive its vibrational linear Stark tuning rate using harmonic frequencies calculated from analytical gradients and computed local electric fields. Comparisons to PE calculations employing an enlarged quantum region as well as to a non-polarizable embedding scheme show that the inclusion of mutual polarization between acetophenone and water is essential in order to capture the structural modifications and the associated frequency shifts observed in water. For more apolar solvents, a proper description of dispersion and exchange–repulsion becomes increasingly important, and the quality of the optimized structures relies to a larger extent on the quality of the Lennard-Jones parameters

  18. Molecular quantum mechanical gradients within the polarizable embedding approach—Application to the internal vibrational Stark shift of acetophenone

    Energy Technology Data Exchange (ETDEWEB)

    List, Nanna Holmgaard, E-mail: nhl@sdu.dk; Jensen, Hans Jørgen Aagaard; Kongsted, Jacob [Department of Physics, Chemistry and Pharmacy, University of Southern Denmark, Campusvej 55, Odense M, Odense DK-5230 Denmark (Denmark); Beerepoot, Maarten T. P.; Gao, Bin; Ruud, Kenneth [Centre for Theoretical and Computational Chemistry, Department of Chemistry, University of Tromsø–The Arctic University of Norway, N-9037 Tromsø (Norway); Olsen, Jógvan Magnus Haugaard [Department of Physics, Chemistry and Pharmacy, University of Southern Denmark, Campusvej 55, Odense M, Odense DK-5230 Denmark (Denmark); Laboratory of Computational Chemistry and Biochemistry, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland)

    2015-01-21

    We present an implementation of analytical quantum mechanical molecular gradients within the polarizable embedding (PE) model to allow for efficient geometry optimizations and vibrational analysis of molecules embedded in large, geometrically frozen environments. We consider a variational ansatz for the quantum region, covering (multiconfigurational) self-consistent-field and Kohn–Sham density functional theory. As the first application of the implementation, we consider the internal vibrational Stark effect of the C=O group of acetophenone in different solvents and derive its vibrational linear Stark tuning rate using harmonic frequencies calculated from analytical gradients and computed local electric fields. Comparisons to PE calculations employing an enlarged quantum region as well as to a non-polarizable embedding scheme show that the inclusion of mutual polarization between acetophenone and water is essential in order to capture the structural modifications and the associated frequency shifts observed in water. For more apolar solvents, a proper description of dispersion and exchange–repulsion becomes increasingly important, and the quality of the optimized structures relies to a larger extent on the quality of the Lennard-Jones parameters.

  19. Quality Of Starking Apples After Exposure To Gamma Radiation As A Quarantine Treatment

    International Nuclear Information System (INIS)

    Mansour, M.; Mohamad, F.; Al-Bachir, M.

    2004-01-01

    Starking apples approaching physiological maturity were exposed, immediately after harvest, to gamma radiation doses ranging from 100 to 400 Gy. The irradiated fruit were stored for six months in a cold storage facility at 1±1 deg. C and 90±5 % RH. Effects of gamma radiation on weight loss, fruit firmness, pH of fruit juice, fruit taste, color and visible injuries were evaluated. The results showed that gamma irradiation increased weight loss, particularly in the first 45 days of storage. Doses higher than 200 Gy, on the other hand, reduced apple firmness after 45 days of storage while a 400 Gy dose decreased fruit pH immediately after irradiation. (Authors)

  20. Rabi oscillations and rapid-passage effects in the molecular-beam CO2-laser Stark spectroscopy of CH3F

    International Nuclear Information System (INIS)

    Adam, A.G.; Gough, T.E.; Isenor, N.R.; Scoles, G.

    1985-01-01

    sub-Doppler molecular-beam laser Stark spectroscopy has been employed to produce high-contrast Rabi oscillations in the ν 3 band of CH 3 F. By varying the intensity of the cw CO 2 laser, up to five complete oscillations were observed before the phenomenon was washed out by rapid-passage effects and damping mechanisms. Besides being useful in clarifying key features of coherent ir molecular-beam spectroscopy, the observation of Rabi oscillations provides one of the most accurate means of directly measuring transition dipole moments. Analysis of the present data on three rovibrational transitions, Q(1,1) -1reverse arrow0, P(1,0) 0reverse arrow0, and R(1,1) 0reverse arrow1, has yielded a rotationless transition dipole moment of 0.21 +- 0.01 D for the ν 3 = 1reverse arrow0 vibration. This result is in agreement with values estimated from both band-intensity and absorption-coefficient data in the literature

  1. Experimental evidence in favour of the Stark mixing of atomic L-subshell states in the boron impact of Au and Bi

    International Nuclear Information System (INIS)

    Padhi, H.C.; Dhal, B.B.; Nandi, T.; Trautmann, D.

    1995-01-01

    L-subshell ionization of Au and Bi induced by boron impact has been investigated for impact energies ranging from 0.48 to 0.88 MeV/μ. The energy dependence of the measured ionization cross section shows, for the first time, a plateau structure for all three subshells. The plateau structure revealed by previous data for proton and helium impact was for the L 1 subshell only and this had been attributed to the bimodal nature of the 2s electron density. The observed plateau structure for all the three subshells and its occurrence at a somewhat lower energy signifies a considerable amount of Stark mixing of target 2s and 2p atomic wavefunctions. Fresh calculations incorporating the Stark mixing effect in target atomic wavefunctions are necessary to improve agreement with the present data. The existing theories, however, are found to be inadequate. (author)

  2. Measurement of Stark width of some Ar I transitions and the investigation of local thermodynamic equilibrium (LTE) in an atmospheric d.c. argon plasma jet

    International Nuclear Information System (INIS)

    Bakshi, V.

    1988-01-01

    The Stark widths of seven Ar I transitions are reported. Axial line shape data from an atmospheric d.c. argon plasma jet were Abel-inverted to obtain radial line shapes. The electron-density was determined by Stark width measurements of the hydrogen H β transition. In the electron-density region of ≤6 x 10 22 m -3 the experimental Ar I Stark widths are fitted to a linear dependence on the electron-density. Values of Stark width extrapolated to other electron densities are compared to measurements reported in the literature on the 4s-4p array. Experimental values are up to 45% smaller than those predicted by Griem's theory of Stark broadening. Conditions for local thermodynamic equilibrium (LTE) to exist in an atmospheric argon plasma jet were studied. The experiment measures the emission coefficient of seven Ar I transitions and the line shape of the hydrogen H beta transition. After transforming the side-on data into radial space the excited neutral argon atom-density and the electron-density are determined. It is found LTE does not exist below an electron-density of 6 x 10 33 m -3 in the experimental conditions

  3. Stark shift of impurity doped quantum dots: Role of noise

    Science.gov (United States)

    Arif, Sk. Md.; Bera, Aindrila; Ghosh, Anuja; Ghosh, Manas

    2018-02-01

    Present study makes a punctilious investigation of the profiles of Stark shift (SS) of doped GaAs quantum dot (QD) under the supervision of Gaussian white noise. A few physical parameters have been varied and the consequent variations in the SS profiles have been monitored. The said physical parameters comprise of magnetic field, confinement potential, dopant location, dopant potential, noise strength, aluminium concentration (only for AlxGa1-x As alloy QD), position-dependent effective mass (PDEM), position-dependent dielectric screening function (PDDSF), anisotropy, hydrostatic pressure (HP) and temperature. The SS profiles unfurl interesting features that heavily depend upon the particular physical quantity concerned, presence/absence of noise and the manner (additive/multiplicative) noise enters the system. The study highlights feasible means of maximizing SS of doped QD in presence of noise by suitable adjustment of several control parameters. The study deems importance in view of technological applications of QD devices where noise plays some prominent role.

  4. Electric Fields near RF Heating and Current Drive Antennas in Tore Supra Measured with Dynamic Stark Effect Spectroscopy*

    Science.gov (United States)

    Klepper, C. C.; Martin, E. H.; Isler, R. C.; Colas, L.; Hillairet, J.; Marandet, Y.; Lotte, Ph.; Colledani, G.; Martin, V.; Hillis, D. L.; Harris, J. H.; Saoutic, B.

    2011-10-01

    Computational models of the interaction between RF waves and the scrape-off layer plasma near ion cyclotron resonant heating (ICRH) and lower hybrid current drive launch antennas are continuously improving. These models mainly predict the RF electric fields produced in the SOL and, therefore, the best measurement for verification of these models would be a direct measurement of these electric fields. Both types of launch antennas are used on Tore Supra and are designed for high power (up to 4MW/antenna) and long pulse (> > 25s) operation. Direct, non-intrusive measurement of the RF electric fields in the vicinity of these structures is achieved by fitting spectral profiles of deuterium Balmer-alpha and Balmer-beta to a model that includes the dynamic, external-field Stark effect, as well as Zeeman splitting and Doppler broadening mechanisms. The measurements are compared to the mentioned, near-field region, RF antenna models. *Work supported in part by the US DOE under Contract No. DE-AC05-00OR22725 with UT-Battelle, LLC.

  5. Multiple Temperature-Sensing Behavior of Green and Red Upconversion Emissions from Stark Sublevels of Er3+

    Directory of Open Access Journals (Sweden)

    Baosheng Cao

    2015-12-01

    Full Text Available Upconversion luminescence properties from the emissions of Stark sublevels of Er3+ were investigated in Er3+-Yb3+-Mo6+-codoped TiO2 phosphors in this study. According to the energy levels split from Er3+, green and red emissions from the transitions of four coupled energy levels, 2H11/2(I/2H11/2(II, 4S3/2(I/4S3/2(II, 4F9/2(I/4F9/2(II, and 2H11/2(I + 2H11/2(II/4S3/2(I + 4S3/2(II, were observed under 976 nm laser diode excitation. By utilizing the fluorescence intensity ratio (FIR technique, temperature-dependent upconversion emissions from these four coupled energy levels were analyzed at length. The optical temperature-sensing behaviors of sensing sensitivity, measurement error, and operating temperature for the four coupled energy levels are discussed, all of which are closely related to the energy gap of the coupled energy levels, FIR value, and luminescence intensity. Experimental results suggest that Er3+-Yb3+-Mo6+-codoped TiO2 phosphor with four pairs of energy levels coupled by Stark sublevels provides a new and effective route to realize multiple optical temperature-sensing through a wide range of temperatures in an independent system.

  6. Stark broadening of the 1640- and 4686-A lines of ionized helium

    International Nuclear Information System (INIS)

    Greene, R.L.

    1976-01-01

    The Stark-broadened profiles of the 1640- and 4686-A lines of ionized helium have been calculated using an approximation to the electron broadening operator in the unified classical-path theory of Smith, Vidal, and Cooper. The approximation is such that the results reproduce the time-ordered impact-theory results in the line center, and the ionized-radiator quasistatic results in the far wings. Sample calculations at n/sub e/ = 10/sup 17/ cm/sup -3/ and T = 40 000 degreeK are found to give significantly more narrow profiles than the corresponding modified-impact-theory results because of a different treatment of the lower-state interaction. Indirect comparison with experiment indicates that the calculated lines are too narrow, but it is expected that the inclusion of neglected effects of ion dynamics and inelastic collisions would improve agreement

  7. Stark effect in a hydrogenic atom or ion treated by the phase-integral method with adjoined papers by A. Hökback and P. O. Fröman

    CERN Document Server

    Fröman, Nanny

    2008-01-01

    This book treats the Stark effect of a hydrogenic atom or ion in a homogeneous electric field. It begins with a thorough review of previous work in this field since 1926. After the Schrödinger equation has been separated with respect to time dependence, centre of mass motion and internal motion, followed by a discussion of its eigenfunctions, the exact development in time of the probability amplitude for a decaying state is obtained by means of a formula analogous to the Fock-Krylov theorem. From this formula one obtains by means of the phase-integral approximation generated from a particular

  8. Quantum logic gates using Stark-shifted Raman transitions in a cavity

    International Nuclear Information System (INIS)

    Biswas, Asoka; Agarwal, G.S.

    2004-01-01

    We present a scheme to realize the basic two-qubit logic gates such as the quantum phase gate and the controlled-NOT gate using a detuned optical cavity interacting with a three-level Raman system. We discuss the role of Stark shifts, which are as important as the terms leading to the two-photon transition. The operation of the proposed logic gates involves metastable states of the atom and hence is not affected by spontaneous emission. These ideas can be extended to produce multiparticle entanglement

  9. FOCUSED FEASIBILITY STUDY OF PHYTOREMEDIATION ALTERNATIVE FOR THE INDUSTRIAL EXCESS LANDFILL SITE IN STARK COUNTY, OHIO.

    Science.gov (United States)

    Focused feasibility study of phytoremediation alternative for the Industrial Excess Landfill site in Stark County, Ohio. More information can be found on the NPL Fact Sheet for this site at www.epa.gov/region5/superfund/npl/ohio/OHD000377971.htm

  10. Anti-Stokes emissions and determination of Stark sub-level diagram of Er3+ ions in KY3F10

    International Nuclear Information System (INIS)

    Boulma, E; Diaf, M; Jouart, J P; Bouffard, M; Doualan, J L; Moncorge, R

    2006-01-01

    We are interested, in this work, in determining the Stark sub-level of Er 3+ ions doping a KY 3 F 10 single crystal with a molar concentration of 1%. We have used a new method of measurement of energies of the ground level and emitting levels from excitation and anti-Stokes emission spectra recorded at liquid nitrogen temperature. This technique is based on a spectral analysis of the anti-Stokes emissions recorded after selective excitation with a red dye tunable laser. Thus, we could determine the Stark sub-levels of the ground and the principal emitting levels in the infrared, visible and near-UV ranges with a very good precision

  11. The influence of static fields on the dynamic Stark spectra of hydrogen Balmer lines

    International Nuclear Information System (INIS)

    Janssen, G.C.A.M.; Jayakumar, R.; Granneman, E.H.A.

    1981-01-01

    In plasmas atomic-line radiation is influenced by static and high frequency fields. A simple method of calculating the Stark profiles of the Balmer α and β lines for the case of one-dimensional fields is discussed. Using a Holtsmark field for the static component, the resulting profile of Balmer α shows a splitting of the satellites. (author)

  12. Application of Stark Tuned Laser for Interferometry and Polarimetry in Plasmas

    International Nuclear Information System (INIS)

    H.K. Park; K.C. Lee; B. Deng; C.W. Domier; M. Johnson; B. Nathan; N.C. Luhmann, Jr.

    2001-01-01

    A Stark-tuned optically pumped far-infrared CH(subscript ''3'')OH laser at 119 mm has been successfully applied in the Far Infrared Tangential Interferometer/Polarimeter (FIReTIP) system for the National Spherical Torus Experiment (NSTX). The system will provide temporally and radially resolved 2-D electron density profile [n(subscript ''e'')(r,t)] and toroidal field profile [B(subscript ''T'')(r,t)] data. In the 2001 campaign, a single channel interferometer system has been operated and tested for the Faraday rotation measurement. A plan for improvement and upgrading of the FIReTIP is discussed

  13. Extremely short pulses via stark modulation of the atomic transition frequencies.

    Science.gov (United States)

    Radeonychev, Y V; Polovinkin, V A; Kocharovskaya, Olga

    2010-10-29

    We propose a universal method to produce extremely short pulses of electromagnetic radiation in various spectral ranges. The essence of the method is a resonant interaction of radiation with atoms under the conditions of adiabatic periodic modulation of atomic transition frequencies by a far-off-resonant control laser field via dynamic Stark shift of the atomic levels and proper adjustment of the control field intensity and frequency, as well as the optical depth of the medium. The potential of the method is illustrated by an example in a hydrogenlike atomic system.

  14. Pre-ionization and spectroscopic diagnostic of plasma generated and confined by magnetic fields

    International Nuclear Information System (INIS)

    Honda, R.Y.

    1980-01-01

    A θ-pinch system has been constructed with pre-heating devices with a total energy of 2 kJ. During this experiment a He Plasma was studied using the following three different diagnostics. a) Magnetic Probes b) Visible Spectroscopy using the Optical Multichannel Analyser - OMA c) Image Converter Camera. The experimental results have been checked with existing theoretical models. The electrical characteristics of the system were determined with the magnetic probe. The Doppler and Stark broadening effects of the λ o = 4686 (angstrom) (HeII) have been used to determine the ionic temperature and electronic density respectively. The time evolution of these parameters was obtained using the OMA. The dynamics of the plasma were observed by high speed photography. Instabilities in the plasma columm have been observed. Good agreement between the experimental and theoretical values was obtained. (author) [pt

  15. Irradiation effects on plasma diagnostic components

    International Nuclear Information System (INIS)

    Nishitani, Takeo; Iida, Toshiyuki; Ikeda, Yujiro

    1998-10-01

    One of the most important issues to develop the diagnostics for the experimental thermonuclear reactor such as ITER is the irradiation effects on the diagnostics components. Typical neutron flux and fluence on the first wall are 1 MW/m 2 and 1 MWa/m 2 , respectively for ITER. In such radiation condition, most of the present diagnostics could not survive so that those will be planed to be installed far from the vacuum vessel. However, some diagnostics sensors such as bolometers and magnetic probes still have to be install inside vessel. And many transmission components for lights, wave and electric signals are inevitable even inside vessel. As a part of this R and D program of the ITER Engineering Design Activities (EDA), we carried out the irradiation tests on the basic materials of the transmission components and in-vessel diagnostics sensors in order to identify radiation hardened materials that can be used for diagnostic systems. (J.P.N.)

  16. Irradiation effects on plasma diagnostic components

    Energy Technology Data Exchange (ETDEWEB)

    Nishitani, Takeo [ed.] [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Iida, Toshiyuki; Ikeda, Yujiro [and others

    1998-10-01

    One of the most important issues to develop the diagnostics for the experimental thermonuclear reactor such as ITER is the irradiation effects on the diagnostics components. Typical neutron flux and fluence on the first wall are 1 MW/m{sup 2} and 1 MWa/m{sup 2}, respectively for ITER. In such radiation condition, most of the present diagnostics could not survive so that those will be planed to be installed far from the vacuum vessel. However, some diagnostics sensors such as bolometers and magnetic probes still have to be install inside vessel. And many transmission components for lights, wave and electric signals are inevitable even inside vessel. As a part of this R and D program of the ITER Engineering Design Activities (EDA), we carried out the irradiation tests on the basic materials of the transmission components and in-vessel diagnostics sensors in order to identify radiation hardened materials that can be used for diagnostic systems. (J.P.N.)

  17. Stark broadening in the laser-induced Cu I and Cu II spectra

    International Nuclear Information System (INIS)

    Skočić, M; Burger, M; Nikolić, Z; Bukvić, S; Djeniže, S

    2013-01-01

    In this work we present the Stark widths (W) of 22 neutral (Cu I) and 100 singly ionized (Cu II) copper spectral lines that have been measured at 18 400 K and 19 300 K electron temperatures and 6.3 × 10  22 m −3 and 2.1 × 10  23 m −3 electron densities, respectively. The experiment is conducted in the laser-induced plasma—the Nd:YAG laser, operating at 532 nm, was used to produce plasma from the copper sample in the residual air atmosphere at a pressure of 8 Pa. The electron temperature and density were estimated by the Boltzmann-plot method and from the Saha equation. The investigated Cu I lines belong to the 4s–4p′, 4s  2 –4p″ and 4p′–4d′ transitions while Cu II spectral lines belong to the 4s–4p, 4p–5s, 4p–4d, 4p–4s  2 , 4d–4f and 4d–v transitions. Comparison with existing experimental data was possible only in the case of 17 Cu II lines due to a lack of experimental and theoretical values. The rest of the data, Stark widths of 22 Cu I and 83 Cu II lines are published for the first time. (paper)

  18. Stark effect investigations of excited cadmium, ytterbium, and thulium I-levels using the methods of double resonance and level crossing

    International Nuclear Information System (INIS)

    Rinkleff, R.H.

    1977-01-01

    Using the method of optical double resonance, the 5s5p 3 P 1 level tensor polarizability of Cadmium has been measured. For this state, various authors have published different results, using different experimental methods. The experimental result presented here is in excellent agreement with the value of Happer, based on level crossing investigations, and agrees well with the theoretical result of Robinson based on a modified Sternheimer approximation, and so gives a reliable value for the tensor polarizability. Furthermore the tensor polarizability of the 6s6p 3 P 1 - level of the even Ytterbium isotopes and the odd Ytterbium 171 nucleus have been measured with the optical double resonance method, and the Stark constant has been calculated based on a given theory and oscillator strengths. Using the methods of optical double resonance and level crossing, the tensor polarizability of 5 excited levels of the Thulium configurations 4f 13 6s6p + 4f 12 5d6s 2 have been measured. From the experimental Stark constants and the angular coefficients of the eigenfunctions calculated by Camus, the radial integrals I(5d, 5p) and I(6p, 5d) are calculated for electric dipole transitions between levels of the configurations 4f 12 5d6s 2 + 4f 13 6s6p and levels of the 4f 12 6p6s 2 + 4f 13 6s5d configurations. The tensor polarizability calculated with these radial integrals show very good agreement with the experimental values. (orig./LH) [de

  19. Radiation effects in IFMIF Li target diagnostic systems

    International Nuclear Information System (INIS)

    Molla, J.; Vila, R.; Shikama, T.; Horiike, H.; Simakov, S.; Ciotti, M.; Ibarra, A.

    2009-01-01

    Diagnostics for the lithium target will be crucial for the operation of IFMIF. Several parameters as the lithium temperature, target thickness or wave pattern must be monitored during operation. Radiation effects may produce malfunctioning in any of these diagnostics due to the exposure to high radiation fields. The main diagnostic systems proposed for the operation of IFMIF are reviewed in this paper from the point of view of radiation damage. The main tools for the assessment of the performance of these diagnostics are the neutronics calculations by using specialised codes and the information accumulated during the last decades on the radiation effects in functional materials, components and diagnostics for ITER. This analysis allows to conclude that the design of some of the diagnostic systems must be revised to assure the high availability required for the target system.

  20. Stark parameters of some asymmetrical Si II lines

    International Nuclear Information System (INIS)

    Ferhat, B; Azzouz, Y; Redon, R; Ripert, M; Lesage, A

    2012-01-01

    Six lines of SiII are experimentally studied in pulsed plasma generated by Nd :Yag laser breakdown on pure solid silicon target. A set of experimental Stark parameters of asymmetrical lines are measured in temperature range from 14 000 K to 18 000 K (using Boltzmann plot). Calculated values of the electron density (using Griem's formula) vary from 1.7 to 6.1 × 10 23 m −3 . Processed spectral lines are 333.982 nm (3s 2 4p -3s 2 6s) and 397.746 nm, 399.177 nm, 399.801 nm, 401.622 nm (3d' 2 F 0 -4f' 4 G) and (3d' 2 F 0 - 4f' 2 G) of astrophysical interest. Asymmetrical line shapes are synthesized by a sum of two semi-Lorentzian distributions. The obtained fit is in good agreement with the measured spectra.

  1. Interband Stark effects in InxGa1-xAs/InyAl1-yAs coupled step quantum wells

    International Nuclear Information System (INIS)

    Kim, J.H.; Kim, T.W.; Yoo, K.H.

    2005-01-01

    The effects of an electric field on the interband transitions in In x Ga 1-x As/In y Al 1-y As coupled step quantum wells have been investigated both experimentally and theoretically. A In x Ga 1-x As/In y Al 1-y As coupled step quantum well sample consisted of the two sets of a 50 Aa In 0.53 Ga 0.47 As shallow quantum well and a 50 Aa In 0.65 Ga 0.35 As deep step quantum well bounded by two thick In 0.52 Al 0.48 As barriers separated by a 30 Aa In 0.52 Al 0.48 As embedded potential barrier. The Stark shift of the interband transition energy in the In x Ga 1-x As/In y Al 1-y As coupled step quantum well is larger than that of the single quantum well, and the oscillator strength in the In x Ga 1-x As/In y Al 1-y As coupled step quantum well is larger than that in a coupled rectangular quantum well. These results indicate that In x Ga 1-x As/In y Al 1-y As coupled step quantum wells hold promise for potential applications in optoelectron devices, such as tunable lasers

  2. Theory of coherent Stark nonlinear spectroscopy in a three-level system

    International Nuclear Information System (INIS)

    Loiko, Yurii; Serrat, Carles

    2007-01-01

    Coherent Stark nonlinear spectroscopy (CSNS) is a spectroscopic tool based on the cancellation of the phase sensitivity at frequency 5ω in the ultrafast four-wave mixing (FWM) of two-color pulses with frequencies ω and 3ω. We develop a theory for CSNS in three-level V-type systems, and reveal that the mechanism for the phase sensitivity at 5ω is the quantum interference between the two primary paths in the FWM of the ω and 3ω fields. We find that the cancellation phenomenon occurs when the probability amplitude of one of these two primary pathways becomes equal to zero due to the competition effect between the two allowed transitions in the V-type system. The analytical expressions that describe the phase-sensitivity phenomenon and the conditions for its cancellation have been derived on the basis of perturbation theory, and are confirmed by numerical integration of the density matrix and Maxwell equations. We argue that CSNS can be utilized, in particular, for the investigation of optically dense media

  3. Topology of surfaces for molecular Stark energy, alignment, and orientation generated by combined permanent and induced electric dipole interactions.

    Science.gov (United States)

    Schmidt, Burkhard; Friedrich, Bretislav

    2014-02-14

    We show that combined permanent and induced electric dipole interactions of linear polar and polarizable molecules with collinear electric fields lead to a sui generis topology of the corresponding Stark energy surfaces and of other observables - such as alignment and orientation cosines - in the plane spanned by the permanent and induced dipole interaction parameters. We find that the loci of the intersections of the surfaces can be traced analytically and that the eigenstates as well as the number of their intersections can be characterized by a single integer index. The value of the index, distinctive for a particular ratio of the interaction parameters, brings out a close kinship with the eigenproperties obtained previously for a class of Stark states via the apparatus of supersymmetric quantum mechanics.

  4. Observation of asymmetric Stark profiles from plasmas created by a picosecond KrF laser

    International Nuclear Information System (INIS)

    Nam, C.H.; Tighe, W.; Suckewer, S.; Seely, J.F.; Feldman, U.; Woltz, L.A.

    1987-10-01

    High-resolution extreme ultraviolet (XUV) spectra from solid targets irradiated by a picosecond KrF* laser focused to 10 16 W/cm 2 have been recorded. The line profiles of transitions in Li-like fluorine and oxygen are asymmetric and up to 2 A in width. Calculations indicate the presence of transitions of the type 2p-3p and other forbidden Stark components. 11 refs., 6 figs

  5. Quantum confined Stark effects of single dopant in polarized hemispherical quantum dot: Two-dimensional finite difference approach and Ritz-Hassé variation method

    Science.gov (United States)

    El Harouny, El Hassan; Nakra Mohajer, Soukaina; Ibral, Asmaa; El Khamkhami, Jamal; Assaid, El Mahdi

    2018-05-01

    Eigenvalues equation of hydrogen-like off-center single donor impurity confined in polarized homogeneous hemispherical quantum dot deposited on a wetting layer, capped by insulated matrix and submitted to external uniform electric field is solved in the framework of the effective mass approximation. An infinitely deep potential is used to describe effects of quantum confinement due to conduction band offsets at surfaces where quantum dot and surrounding materials meet. Single donor ground state total and binding energies in presence of electric field are determined via two-dimensional finite difference approach and Ritz-Hassé variation principle. For the latter method, attractive coulomb correlation between electron and ionized single donor is taken into account in the expression of trial wave function. It appears that off-center single dopant binding energy, spatial extension and radial probability density are strongly dependent on hemisphere radius and single dopant position inside quantum dot. Influence of a uniform electric field is also investigated. It shows that Stark effect appears even for very small size dots and that single dopant energy shift is more significant when the single donor is near hemispherical surface.

  6. Experimental transition probabilities and Stark parameters of singly ionized noble gases

    OpenAIRE

    Belmonte Sainz-Ezquerra, María Teresa

    2016-01-01

    La medida de parámetros atómicos, tales como las probabilidades de transición y las anchuras y desplazamientos Stark, es de gran importancia no solo en el campo de la física teórica y atómica, sino también en el diagnóstico de cualquier fuente emisora de radiación y en el área de la astrofísica. El objetivo de esta tesis doctoral es la medida de nuevos datos atómicos mediante una técnica de espectroscopia de emisión de plasmas. En concreto, este trabajo se ha centrado en: 1) Me...

  7. Topology of surfaces for molecular Stark energy, alignment, and orientation generated by combined permanent and induced electric dipole interactions

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Burkhard, E-mail: burkhard.schmidt@fu-berlin.de [Institute for Mathematics, Freie Universität Berlin, Arnimallee 6, D-14195 Berlin (Germany); Friedrich, Bretislav, E-mail: brich@fhi-berlin.mpg.de [Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, D-14195 Berlin (Germany)

    2014-02-14

    We show that combined permanent and induced electric dipole interactions of linear polar and polarizable molecules with collinear electric fields lead to a sui generis topology of the corresponding Stark energy surfaces and of other observables – such as alignment and orientation cosines – in the plane spanned by the permanent and induced dipole interaction parameters. We find that the loci of the intersections of the surfaces can be traced analytically and that the eigenstates as well as the number of their intersections can be characterized by a single integer index. The value of the index, distinctive for a particular ratio of the interaction parameters, brings out a close kinship with the eigenproperties obtained previously for a class of Stark states via the apparatus of supersymmetric quantum mechanics.

  8. Vibrational Stark Effect of the Electric-Field Reporter 4-Mercaptobenzonitrile as a Tool for Investigating Electrostatics at Electrode/SAM/Solution Interfaces

    Directory of Open Access Journals (Sweden)

    Peter Hildebrandt

    2012-06-01

    Full Text Available 4-mercaptobenzonitrile (MBN in self-assembled monolayers (SAMs on Au and Ag electrodes was studied by surface enhanced infrared absorption and Raman spectroscopy, to correlate the nitrile stretching frequency with the local electric field exploiting the vibrational Stark effect (VSE. Using MBN SAMs in different metal/SAM interfaces, we sorted out the main factors controlling the nitrile stretching frequency, which comprise, in addition to external electric fields, the metal-MBN bond, the surface potential, and hydrogen bond interactions. On the basis of the linear relationships between the nitrile stretching and the electrode potential, an electrostatic description of the interfacial potential distribution is presented that allows for determining the electric field strengths on the SAM surface, as well as the effective potential of zero-charge of the SAM-coated metal. Comparing this latter quantity with calculated values derived from literature data, we note a very good agreement for Au/MBN but distinct deviations for Ag/MBN which may reflect either the approximations and simplifications of the model or the uncertainty in reported structural parameters for Ag/MBN. The present electrostatic model consistently explains the electric field strengths for MBN SAMs on Ag and Au as well as for thiophenol and mercaptohexanoic acid SAMs with MBN incorporated as a VSE reporter.

  9. The Stark-crossing method for the simultaneous determination of the electron temperature and density in plasmas

    International Nuclear Information System (INIS)

    Torres, J; Carabano, O; Fernandez, M; Rubio, S; Alvarez, R; Rodero, A; Lao, C; Quintero, M C; Gamero, A; Sola, A

    2006-01-01

    The use of the Stark broadening of Balmer lines spontaneously emitted by atmospheric-pressure plasmas as a method to determine both the electron density and temperature in high-pressure plasmas is discussed in this paper. This method is applied to argon and helium plasmas produced in microwave discharges. Especially for Ar plasmas, valuable and reliable results are obtained

  10. Quantification of the impact of large and small-scale instabilities on the fast-ion confinement in ASDEX Upgrade

    DEFF Research Database (Denmark)

    Geiger, B.; Weiland, M.; Mlynek, A.

    2015-01-01

    with up to 10 MW of heating power, the fast-ion measurements agree best with the theoretical predictions that assume a weak level anomalous fast-ion transport. This is also in agreement with measurements of the internal inductance, a Motional Stark Effect diagnostic and a novel polarimetry diagnostic...

  11. Stark tuning and electrical charge state control of single divacancies in silicon carbide

    Science.gov (United States)

    de las Casas, Charles F.; Christle, David J.; Ul Hassan, Jawad; Ohshima, Takeshi; Son, Nguyen T.; Awschalom, David D.

    2017-12-01

    Neutrally charged divacancies in silicon carbide (SiC) are paramagnetic color centers whose long coherence times and near-telecom operating wavelengths make them promising for scalable quantum communication technologies compatible with existing fiber optic networks. However, local strain inhomogeneity can randomly perturb their optical transition frequencies, which degrades the indistinguishability of photons emitted from separate defects and hinders their coupling to optical cavities. Here, we show that electric fields can be used to tune the optical transition frequencies of single neutral divacancy defects in 4H-SiC over a range of several GHz via the DC Stark effect. The same technique can also control the charge state of the defect on microsecond timescales, which we use to stabilize unstable or non-neutral divacancies into their neutral charge state. Using fluorescence-based charge state detection, we show that both 975 nm and 1130 nm excitation can prepare their neutral charge state with near unity efficiency.

  12. Stark shifts and widths of a hydrogen atom in Debye plasmas

    International Nuclear Information System (INIS)

    Yu, A.C.H.; Ho, Y.K.

    2005-01-01

    A computational scheme has been developed and used to investigate the influence of the plasma environments on modified atomic autoionization for isolated atoms/ions by using the complex coordinate rotation method which is proved to be a very simple and powerful tool to analyze the position and the width of a resonance. The Debye screening potential is employed to describe the effects of the plasma environments. Stark shifts and widths on the ground state of hydrogen are reported for field strength up to F=0.12 a.u. Slater-type basis wave functions are used to describe the system and angular-momentum states up to L=11 are included when the external electric field is turned on. Converged results are obtained by using different maximum angular-momentum states. The modified autoionization for various Debye lengths ranging from infinite to a small value of 0.86 are reported. It has been observed that for a given temperature and under the influence of a given external electric field, the resonance energy and the autoionization width increase for increasing electron density in the plasma. A discussion on the physical implication of our results is made

  13. To Bind Ties between the School and Tribal Life: Educational Policy for Africans under George Stark in Zimbabwe.

    Science.gov (United States)

    Mungazi, Dickson A.

    1989-01-01

    Contends that educational policy in Zimbabwe from 1934 to 1954 served the political purposes of the colonial government and neglected genuine educational development of the colonized Africans. During George Stark's tenure as Director of Native Education, Zimbabweans were consigned to "practical training" programs and were denied access…

  14. The effects of ultrasonic pretreatment and structural changes during the osmotic dehydration of the 'Starking' apple (Malus domestica Borkh)

    Energy Technology Data Exchange (ETDEWEB)

    Rosa-Mendoza, M. E.; Fernandez-Munoz, J. L.; Arjona-Roman, J. L.

    2012-11-01

    During the osmotic dehydration (OD) of fruit, the cell membrane displays a high resistance to mass transfer, thereby reducing the dehydration rate. To reduce thermal damage to cell membranes, alternative methods have recently been introduced to reduce the initial moisture content and/or modify the structure of fruit tissue. The aim of this work was to evaluate the effects of an ultrasound (US) pretreatment for OD on the effective diffusion coefficients and to observe the changes in the molecular structure of 'Starking' apple cubes by Fourier-transform infrared spectroscopy (FTIR) during a 3 h process using a 45 dregee Bx sucrose solution at 60 degree centigrade. In the pretreatment step, apple samples were immersed in an ultrasonic bath at 45 kHz for 20 min. The effective diffusion coefficients for water (Dew) and solids (Des) were calculated from the observed osmotic kinetics according to Fick's second law for the transient state. The solids coefficients were higher than the water coefficients in both processes due to the concentration difference (De = 7.7 × 10{sup -}9 and 9.7 × 10{sup -}9 m{sup 2} s{sup -}1 for ODUS). The structural changes were determined by FTIR by measuring the molecular vibration frequency for sucrose. The 1,500-900 cm{sup -}1 region of the infrared spectra was used to monitor the effect of sucrose concentration on fruit structure. We observed that the first bonds formed were C-H and C-O-C stretching (at 920 and 1,129 cm{sup -}1, respectively) in the sucrose skeleton and glycoside bonds among sucrose molecules. The water concentration affected the diffusion coefficient significantly due to its dependence on the physical structure of the food. (Author) 27 refs.

  15. Line Shape Modeling for the Diagnostic of the Electron Density in a Corona Discharge

    Directory of Open Access Journals (Sweden)

    Joël Rosato

    2017-09-01

    Full Text Available We present an analysis of spectra observed in a corona discharge designed for the study of dielectrics in electrical engineering. The medium is a gas of helium and the discharge was performed at the vicinity of a tip electrode under high voltage. The shape of helium lines is dominated by the Stark broadening due to the plasma microfield. Using a computer simulation method, we examine the sensitivity of the He 492 nm line shape to the electron density. Our results indicate the possibility of a density diagnostic based on passive spectroscopy. The influence of collisional broadening due to interactions between the emitters and neutrals is discussed.

  16. The importance of the radial electric field (Er) on interpretation of motional Stark effect measurements of the q profile in DIII-D high performance plasmas

    International Nuclear Information System (INIS)

    Rice, B.W.; Lao, L.L.; Burrell, K.H.; Greenfield, C.M.; Lin-Liu, Y.R.

    1997-06-01

    The development of enhanced confinement regimes such as negative central magnetic shear (NCS) and VH-mode illustrates the importance of the q profile and ExB velocity shear in improving stability and confinement in tokamak plasmas. Recently, it was realized that the large values of radial electric field observed in these high performance plasmas, up to 200 kV/m in DIII-D, have an effect on the interpretation of motional Stark effect (MSE) measurements of the q profile. It has also been shown that, with additional MSE measurements, one can extract a direct measurement of E r in addition to the usual poloidal field measurement. During a recent vent on DIII-D, 19 additional MSE channels with new viewing angles were added (for a total of 35 channels) in order to descriminate between the neutral beam v b x B electric field and the plasma E r field. In this paper, the system upgrade will be described and initial measurements demonstrating simultaneous measurement of the q and E r profiles will be presented

  17. Spectroscopic diagnostics of industrial plasmas

    International Nuclear Information System (INIS)

    Joshi, N.K.

    2004-01-01

    Plasmas play key role in modern industry and are being used for processing micro electronic circuits to the destruction of toxic waste. Characterization of industrial plasmas which includes both 'thermal plasmas' and non-equilibrium plasmas or 'cold plasmas' in industrial environment offers quite a challenge. Numerous diagnostic techniques have been developed for the measurement of these partially ionized plasma and/or particulate parameters. The 'simple' non-invasive spectroscopic methods for characterization of industrial plasmas will be discussed in detail in this paper. The excitation temperature in thermal (DC/RF) plasma jets has been determined using atomic Boltzmann technique. The central axis temperature of thermal plasma jets in a spray torch can be determined using modified atomic Boltzmann technique with out using Abel inversion. The Stark broadening of H β and Ar-I (430 nm) lines have been used to determine the electron number density in thermal plasma jets. In low-pressure non-equilibrium argon plasma, electron temperature has been measured using the Corona model from the ratio of line intensities of atomic and ionic transitions. (author)

  18. Trends with coverage and pH in Stark tuning rates for CO on Pt(1 1 1) electrodes

    International Nuclear Information System (INIS)

    Uddin, Jamal; Anderson, Alfred B.

    2013-01-01

    The general understanding of so-called electrochemical Stark tuning rates, that is, the potential dependence of vibrational frequency of CO adsorbed on Pt(1 1 1), has developed over the past thirty years in terms of two semiempirical models. The first is the Fermi level shift model used in non-self-consistent-field one-electron molecular orbital theory. This approach has provided qualitative understanding in terms of Fermi level-dependent variations in σ and π orbital bonding between CO and the electrode surface atoms. The second is the use of self-consistent-field theory with surface charging to create adjustable electric fields. Adsorbed CO then reacts to the field in a classical Stark effect with some small uncharacterized Fermi level shift superimposed. It is now possible, using two-dimensional density functional theory, including electrolyte polarization from surface charging, and the dielectric continuum to approximate solvation energy, to calculate the tuning rate in response to shifts in the Fermi level and electrode potential caused by changing the surface charge density. Here we apply this first principles method to calculate trends in the tuning rate for CO adsorbed on 1-fold Pt(1 1 1) sites with changes in CO(ads) coverage and with changes in electrolyte pH. The tuning rate is calculated to decrease as the coverage is increased and, for high coverage, to increase as the pH is increased. These trends are shown to be in qualitative agreement with the very little existing experimental data for these trends

  19. Direct measurement of electron density in microdischarge at atmospheric pressure by Stark broadening

    International Nuclear Information System (INIS)

    Dong Lifang; Ran Junxia; Mao Zhiguo

    2005-01-01

    We present a method and results for measurement of electron density in atmospheric-pressure dielectric barrier discharge. The electron density of microdischarge in atmospheric pressure argon is measured by using the spectral line profile method. The asymmetrical deconvolution is used to obtain Stark broadening. The results show that the electron density in single filamentary microdischarge at atmospheric pressure argon is 3.05x10 15 cm -3 if the electron temperature is 10,000 K. The result is in good agreement with the simulation. The electron density in dielectric barrier discharge increases with the increase of applied voltage

  20. Self-calibrating magnetic field diagnostics in beam emission spectroscopy

    International Nuclear Information System (INIS)

    Voslamber, D.

    1995-01-01

    Magnetic field diagnostics in tokamaks using the motional Stark effect in fast neutral beams have been based on two kinds of polarimetry which we call ''static'' and ''dynamic.'' A detailed analysis shows that static polarimetry presents a number of advantages over dynamic polarimetry, provided it is made complete in the sense that a sufficient number of polarization analyzers are installed and different parts of the spectrum are explored to yield full information on the set of unknowns inherent in the problem. A detailed scheme of complete static polarimetry is proposed, including the case where an in-vessel mirror with changing characteristics (coating by impurities) is placed in front of the optical detection system. The main merit of this scheme relies on the fact that it is self-calibrating with respect to both the characteristics of the mirror and the transmission of the different polarization channels, the latter item implying that it is uniquely based on relative measurements of spectra. Further advantages are a greater flexibility with regard to different kinds of diagnostics and the circumstance that the technical equipment is less involved. The above scheme is based on a detection system of moderate etendue exploiting a large spectral domain, which is the regime where static polarimetry usually operates. It is also possible, however, to work with large etendue and a small spectral domain, such as commonly adopted in dynamic polarimetry. Using such a regime, static polarimetry loses the advantages mentioned above but gains, as a new advantage, the benefit of a comparatively lower level of photon noise. copyright 1995 American Institute of Physics

  1. Extensión del Formalismo de Orbitales de Defecto Cuántico al tratamiento del efecto Stark (SQDO).

    Science.gov (United States)

    Menéndez, J. M.; Martín, I.; Velasco, A. M.

    El estudio experimental de las interacciones de átomos Rydberg altamente excitados con campos eléctricos ha experimentado un creciente interés durante las dos últimas décadas debido, en gran medida, al desarrollo de nuevas técnicas para crear y estudiar átomos Rydberg en el laboratorio. Acompañando a estas nuevas técnicas experimentales, es necesario el desarrollo de modelos teóricos que nos permitan contrastar sus medidas y conocer mejor los fundamentos de los mismos. Desde el punto de vista teórico el conocimiento del desdoblamiento de los niveles energéticos de un átomo en función de la magnitud del campo eléctrico aplicado (lo que se conoce como mapa Stark) es el mejor punto de partida para la descripción del sistema y un prerrequisito fundamental para el cálculo de distintas propiedades atómicas en presencia del campo eléctrico tales como intensidades de transición, umbrales de ionización de campo eléctrico, tiempos de vida, posición y anchura de cruces evitados, etc. En este trabajo presentamos la adaptación del método de orbitales de defecto cuántico [1,2,3] al tratamiento del efecto Stark (SQDO) [4] y su aplicación al cálculo de los desdoblamientos energéticos y fuerzas de oscilador de estados Rydberg en los átomos de Li, Na y K. El propósito de este estudio es, por un lado, desarrollar métodos fiables para la determinación de propiedades atómicas en presencia de campos eléctricos y, por otro, mostrar la fiabilidad de las funciones de onda QDO en la descripción del efecto Stark en sistemas atómicos.

  2. Dental and dental hygiene students' diagnostic accuracy in oral radiology: effect of diagnostic strategy and instructional method.

    Science.gov (United States)

    Baghdady, Mariam T; Carnahan, Heather; Lam, Ernest W N; Woods, Nicole N

    2014-09-01

    There has been much debate surrounding diagnostic strategies and the most appropriate training models for novices in oral radiology. It has been argued that an analytic approach, using a step-by-step analysis of the radiographic features of an abnormality, is ideal. Alternative research suggests that novices can successfully employ non-analytic reasoning. Many of these studies do not take instructional methodology into account. This study evaluated the effectiveness of non-analytic and analytic strategies in radiographic interpretation and explored the relationship between instructional methodology and diagnostic strategy. Second-year dental and dental hygiene students were taught four radiographic abnormalities using basic science instructions or a step-by-step algorithm. The students were tested on diagnostic accuracy and memory immediately after learning and one week later. A total of seventy-three students completed both immediate and delayed sessions and were included in the analysis. Students were randomly divided into two instructional conditions: one group provided a diagnostic hypothesis for the image and then identified specific features to support it, while the other group first identified features and then provided a diagnosis. Participants in the diagnosis-first condition (non-analytic reasoning) had higher diagnostic accuracy then those in the features-first condition (analytic reasoning), regardless of their learning condition. No main effect of learning condition or interaction with diagnostic strategy was observed. Educators should be mindful of the potential influence of analytic and non-analytic approaches on the effectiveness of the instructional method.

  3. An expanded genetic code for probing the role of electrostatics in enzyme catalysis by vibrational Stark spectroscopy.

    Science.gov (United States)

    Völler, Jan-Stefan; Biava, Hernan; Hildebrandt, Peter; Budisa, Nediljko

    2017-11-01

    To find experimental validation for electrostatic interactions essential for catalytic reactions represents a challenge due to practical limitations in assessing electric fields within protein structures. This review examines the applications of non-canonical amino acids (ncAAs) as genetically encoded probes for studying the role of electrostatic interactions in enzyme catalysis. ncAAs constitute sensitive spectroscopic probes to detect local electric fields by exploiting the vibrational Stark effect (VSE) and thus have the potential to map the protein electrostatics. Mapping the electrostatics in proteins will improve our understanding of natural catalytic processes and, in beyond, will be helpful for biocatalyst engineering. This article is part of a Special Issue entitled "Biochemistry of Synthetic Biology - Recent Developments" Guest Editor: Dr. Ilka Heinemann and Dr. Patrick O'Donoghue. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Does MR imaging effectively replace diagnostic arthroscopy

    International Nuclear Information System (INIS)

    Ruwe, P.; McCarthy, S.; Wright, J.; Randall, L.; Lynch, K.; Jokyl, P.

    1990-01-01

    This paper determines if MR imaging reduces the number of diagnostic arthroscopic procedures required in patients with knee complaints and if MR imaging is cost-effective compared with diagnostic arthroscopy. The cohort analysis consists of 100 patients seen in a sports medicine clinic by two orthopedic surgeons who agreed on well-defined criteria for performing MR imaging and arthroscopy. Each orthopedic surgeon referring a patient for MR imaging checked a form regarding the plans for arthroscopy. Outcome analysis was conducted at 6 months

  5. Modeling sequential context effects in diagnostic interpretation of screening mammograms.

    Science.gov (United States)

    Alamudun, Folami; Paulus, Paige; Yoon, Hong-Jun; Tourassi, Georgia

    2018-07-01

    Prior research has shown that physicians' medical decisions can be influenced by sequential context, particularly in cases where successive stimuli exhibit similar characteristics when analyzing medical images. This type of systematic error is known to psychophysicists as sequential context effect as it indicates that judgments are influenced by features of and decisions about the preceding case in the sequence of examined cases, rather than being based solely on the peculiarities unique to the present case. We determine if radiologists experience some form of context bias, using screening mammography as the use case. To this end, we explore correlations between previous perceptual behavior and diagnostic decisions and current decisions. We hypothesize that a radiologist's visual search pattern and diagnostic decisions in previous cases are predictive of the radiologist's current diagnostic decisions. To test our hypothesis, we tasked 10 radiologists of varied experience to conduct blind reviews of 100 four-view screening mammograms. Eye-tracking data and diagnostic decisions were collected from each radiologist under conditions mimicking clinical practice. Perceptual behavior was quantified using the fractal dimension of gaze scanpath, which was computed using the Minkowski-Bouligand box-counting method. To test the effect of previous behavior and decisions, we conducted a multifactor fixed-effects ANOVA. Further, to examine the predictive value of previous perceptual behavior and decisions, we trained and evaluated a predictive model for radiologists' current diagnostic decisions. ANOVA tests showed that previous visual behavior, characterized by fractal analysis, previous diagnostic decisions, and image characteristics of previous cases are significant predictors of current diagnostic decisions. Additionally, predictive modeling of diagnostic decisions showed an overall improvement in prediction error when the model is trained on additional information about

  6. METHODS OF DIAGNOSTIC EFFECTIVENESS ORGANIZATIONAL CHANGES IN CARGO MOTOR TRANSPORTATION ORGANIZATIONS

    Directory of Open Access Journals (Sweden)

    Denis Sergeevich Antipov

    2017-03-01

    Full Text Available The article propose methods of diagnostic effectiveness organizational changes in cargo motor transportation organizations. The article contain the main results approbation of the developed methods of diagnostic effectiveness organizational changes in cargo motor transportation organizations in 37 cargo motor transportation organizations of Saint-Petersburg and the Leningrad Region. Constructed diagrams of conformity specific weights resulting from organizational changes in cargo motor transportation organizations. Presents diagrams effectiveness organizational changes in cargo motor transportation organizations at every stages of the life cycle. The goal of the present paper is to development methods of diagnostic effectiveness organizational changes in cargo motor transportation organizations.

  7. Entanglement analysis of a two-atom nonlinear Jaynes-Cummings model with nondegenerate two-photon transition, Kerr nonlinearity, and two-mode Stark shift

    Science.gov (United States)

    Baghshahi, H. R.; Tavassoly, M. K.; Faghihi, M. J.

    2014-12-01

    An entangled state, as an essential tool in quantum information processing, may be generated through the interaction between light and matter in cavity quantum electrodynamics. In this paper, we study the interaction between two two-level atoms and a two-mode field in an optical cavity enclosed by a medium with Kerr nonlinearity in the presence of a detuning parameter and Stark effect. It is assumed that the atom-field coupling and third-order susceptibility of the Kerr medium depend on the intensity of the light. In order to investigate the dynamics of the introduced system, we obtain the exact analytical form of the state vector of the considered atom-field system under initial conditions which may be prepared for the atoms (in a coherent superposition of their ground and upper states) and the fields (in a standard coherent state). Then, in order to evaluate the degree of entanglement between the subsystems, we investigate the dynamics of the entanglement by employing the entanglement of formation. Finally, we analyze in detail the influences of the Stark shift, the deformed Kerr medium, the intensity-dependent coupling, and also the detuning parameter on the behavior of this measure for different subsystems. The numerical results show that the amount of entanglement between the different subsystems can be controlled by choosing the evolved parameters appropriately.

  8. Entanglement analysis of a two-atom nonlinear Jaynes–Cummings model with nondegenerate two-photon transition, Kerr nonlinearity, and two-mode Stark shift

    International Nuclear Information System (INIS)

    Baghshahi, H R; Tavassoly, M K; Faghihi, M J

    2014-01-01

    An entangled state, as an essential tool in quantum information processing, may be generated through the interaction between light and matter in cavity quantum electrodynamics. In this paper, we study the interaction between two two-level atoms and a two-mode field in an optical cavity enclosed by a medium with Kerr nonlinearity in the presence of a detuning parameter and Stark effect. It is assumed that the atom–field coupling and third-order susceptibility of the Kerr medium depend on the intensity of the light. In order to investigate the dynamics of the introduced system, we obtain the exact analytical form of the state vector of the considered atom–field system under initial conditions which may be prepared for the atoms (in a coherent superposition of their ground and upper states) and the fields (in a standard coherent state). Then, in order to evaluate the degree of entanglement between the subsystems, we investigate the dynamics of the entanglement by employing the entanglement of formation. Finally, we analyze in detail the influences of the Stark shift, the deformed Kerr medium, the intensity-dependent coupling, and also the detuning parameter on the behavior of this measure for different subsystems. The numerical results show that the amount of entanglement between the different subsystems can be controlled by choosing the evolved parameters appropriately. (paper)

  9. Observation of interference between stark and electric quadrupole transitions in LIF from He atoms in plasmas

    International Nuclear Information System (INIS)

    Takiyama, K.; Namba, S.; Furukawa, S.; Oda, T.; James, B.W.; Andruczyk, D.

    2004-01-01

    Interference between Stark-induced dipole and electric quadrupole amplitudes was observed in a He hollow cathode plasma with axial magnetic field perpendicular to the sheath electric field E by laser-induced fluorescence (LIF) method. Circularly polarized LIF signals were observed in the sheath region. Spatial profile of the degree of polarization P c showed characteristic features of the interference. Using theoretically calculated P c -E relationship, E-profile was successfully obtained form the measure P c . (author)

  10. WATER TEMPERATURE and other data from STARK in the Mediterranean Sea from 1992-01-07 to 1992-01-31 (NODC Accession 9200044)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data in this accession were collected in Mediterranean Sea from ship STARK between January 7, 1992 and January 31, 1992. The real time data of water temperature...

  11. The influence of Stark shift and plasma inhomogeneity on half width of self-absorbed line profiles in the plasma emission spectrum

    International Nuclear Information System (INIS)

    Catsalap, K.Yu.; Ershov-Pavlov, E.A.

    2005-01-01

    Emission spectral line profiles are commonly used for the evaluation of local plasma parameters. The plasma parameters and local line profiles are related in a rather simple way: e.g. at quadratic Stark broadening, the local line half widths and shifts are proportional to the electron density. For homogeneous optically thin plasmas, there is no difference in the line profiles of plasma emission and emissivity spectra. However for inhomogeneous source, the profiles are different due to spatial dependence of electron density and plasma temperature: profiles in the plasma emission are a superposition of different local ones. A transition from the recorded to local profiles is usually performed by tomography techniques. As the result, the measurement procedure is getting slower and additional errors occurs. For transparent plasmas, an approach was developed to evaluate local profiles from as recorded spectra using relations found by modeling. However, for semi-transparent plasmas the relation between the recorded and local profiles is more complicated one. With the optical thickness t increase, profile half width Δλ in the plasma emission spectrum changes much comparing to the profile half width Δλ 0 in the spectrum of optically thin plasma. The ratio t h =Δλ/Δλ 0 on τ for dispersion profile and homogeneous plasma can be written as t h =(-1-τ/ln((1+e -τ )/2)) 1/2 . When Δλ and τ are known, the function allows obtaining Δλ 0 , i. e. reducing the problem to the transparent plasma diagnostics. However, the plasma is nearly always inhomogeneous and the value t depends significantly on plasma inhomogeneity and on Stark parameters ratio d/w. Here, the dependence t(τ) for plasmas of different inhomogeneity rates has been obtained by the numerical simulation. The radiation transfer equation has been solved to calculate the spectral line profiles for LTE-plasma of known composition and distribution of temperature along the observation line. The temperature

  12. Comparing the relative cost-effectiveness of diagnostic studies: a new model

    International Nuclear Information System (INIS)

    Patton, D.D.; Woolfenden, J.M.; Wellish, K.L.

    1986-01-01

    We have developed a model to compare the relative cost-effectiveness of two or more diagnostic tests. The model defines a cost-effectiveness ratio (CER) for a diagnostic test as the ratio of effective cost to base cost, only dollar costs considered. Effective cost includes base cost, cost of dealing with expected side effects, and wastage due to imperfect test performance. Test performance is measured by diagnostic utility (DU), a measure of test outcomes incorporating the decision-analytic variables sensitivity, specificity, equivocal fraction, disease probability, and outcome utility. Each of these factors affecting DU, and hence CER, is a local, not universal, value; these local values strongly affect CER, which in effect becomes a property of the local medical setting. When DU = +1 and there are no adverse effects, CER = 1 and the patient benefits from the test dollar for dollar. When there are adverse effects effective cost exceeds base cost, and for an imperfect test DU 1. As DU approaches 0 (worthless test), CER approaches infinity (no effectiveness at any cost). If DU is negative, indicating that doing the test at all would be detrimental, CER also becomes negative. We conclude that the CER model is a useful preliminary method for ranking the relative cost-effectiveness of diagnostic tests, and that the comparisons would best be done using local values; different groups might well arrive at different rankings. (Author)

  13. Study of Stark Effect in n-doped 1.55 μm InN0.92yP1-1.92yBiy/InP MQWs

    Science.gov (United States)

    Bilel, C.; Chakir, K.; Rebey, A.; Alrowaili, Z. A.

    2018-05-01

    The effect of an applied electric field on electronic band structure and optical absorption properties of n-doped InN0.92y P1-1.92y Bi y /InP multiple quantum wells (MQWs) was theoretically studied using a self-consistent calculation combined with the 16-band anti-crossing model. The incorporation of N and Bi atoms into an InP host matrix leads to rapid reduction of the band gap energy covering a large infrared range. The optimization of the well parameters, such as the well/barrier widths, N/Bi compositions and doping density, allowed us to obtain InN0.92y P1-1.92y Bi y /InP MQWs operating at the wavelength 1.55 μm. Application of the electric field causes a red-shift of the fundamental transition energy T 1 accompanied by a significant change in the spatial distribution of confined electron density. The Stark effect on the absorption coefficient of n-doped InN0.92y P1-1.92y Bi y /InP MQWs was investigated. The Bi composition of these MQWs was adjusted for each electric field value in order to maintain the wavelength emission at 1.55 μm.

  14. Turbidity, SOLAR RADIATION - ATMOSPHERIC and other data from STARK in the NW Atlantic from 1991-01-01 to 1991-12-31 (NODC Accession 9600031)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Ocean Station Data from 17 stations; and Conductivity, Temperature and Depth (CTD) data from 49 casts were collected using ship Stark during cruises # 688-711....

  15. Effects of radiation exposure from radiopharmaceuticals used in diagnostic studies

    International Nuclear Information System (INIS)

    Witcofski, R.L.

    1981-01-01

    In the United States about 90 percent of man-made radiation exposure to the general population is from the use of radiation in diagnostic medicine. Although the doses of radiation from these procedures to individuals are generally quite small, large numbers of people are exposed. Estimates of the radiation doses associated with such use in the healing arts are approximately 15 million person-rem to the general population from diagnostic x ray and 3.3 million person-rem from the diagnostic use of radiopharmaceuticals. The purpose of this paper is to present what is known about the possible effects of radiation from diagnostic radiopharmaceuticals

  16. A Comprehensive Diagnostic Framework for Evaluating Business Intelligence and Analytics Effectiveness

    Directory of Open Access Journals (Sweden)

    Neil Foshay

    2015-09-01

    Full Text Available Business intelligence and analytics (BIA initiatives are costly, complex and experience high failure rates. Organizations require effective approaches to evaluate their BIA capabilities in order to develop strategies for their evolution. In this paper, we employ a design science paradigm to develop a comprehensive BIA effectiveness diagnostic (BIAED framework that can be easily operationalized. We propose that a useful BIAED framework must assess the correct factors, should be deployed in the proper process context and acquire the appropriate input from different constituencies within an organization. Drawing on the BIAED framework, we further develop an online diagnostic toolkit that includes a comprehensive survey instrument. We subsequently deploy the diagnostic mechanism within three large organizations in North America (involving over 1500 participants and use the results to inform BIA strategy formulation. Feedback from participating organizations indicates that BIA diagnostic toolkit provides insights that are essential inputs to strategy development. This work addresses a significant research gap in the area of BIA effectiveness assessment.

  17. Theoretical Stark widths and shifts of spectral lines of 2p5nf and 2p55g configurations of Mg III

    International Nuclear Information System (INIS)

    Moreno-Díaz, Cristina; Alonso-Medina, Aurelia; Colón, Cristóbal

    2014-01-01

    In this paper, we report theoretical Stark widths and shifts calculated using the Griem semi-empirical approach, which corresponds to 111 spectral lines of Mg III. The values of these Stark broadening parameters of spectral lines that arise from levels of 2p 5 nf and 2p 5 5g configurations of Mg III are presented in the literature for the first time. The aim of this work is to provide values to estimate the electron density of plasma Mg III in astrophysics and industrial applications. The data are presented for the temperatures T = 0.5–10.0 (10 4 K) and for an electron density of 10 17 cm −3 . The matrix of elements used in these calculations has been determined from 23 configurations of Mg III: 2s 2 2p 6 , 2s 2 2p 5 3p, 2s 2 2p 5 4p, 2s 2 2p 5 4f and 2s 2 2p 5 5f for the even parity and 2s 2 2p 5 ns (n = 3–6), 2s 2 2p 5 nd (n = 3–9), 2s 2 2p 5 5g and 2s2p 6 np (n = 3–8) for the odd parity. For the intermediate coupling calculations, we use the standard method of least square fitting from experimental energy levels by means of Cowan’s computer code. Lines with wavelengths of 134.6460, 135.2800, 189.0380, 190.0043, 192.8424, 408.2939 and 409.4375 nm have high probabilities and also have high values of broadening. Therefore, these lines can be used in some applications. A common regularity for the Stark width of the 189.038 nm spectral line of Mg III is discussed. (paper)

  18. Fulltext PDF

    Indian Academy of Sciences (India)

    ized neon and argon for laboratory plasma diagnostics. The shifts have been compared with existing experimental values. The obtained data will be included in the STARK-B database, which is a part of the Virtual. Atomic and Molecular Data Center – VAMDC. Key words. Stark broadening—atomic data—Ne I: line profiles.

  19. D-T radiation effects on TFTR diagnostics

    International Nuclear Information System (INIS)

    Ramsey, A.T.

    1994-10-01

    For a 50%-50% deuterium-tritium plasma, the neutron production is 80x higher and the total energy release is 200x higher than the same plasma composed only of deuterium. With this increase in radiation, diagnostics which see only negligible amounts of noise during DD operation may find themselves overwhelmed during DT. The neutrons are not only more numerous, but have 6x as much energy, which causes the calculated 2.4x increase in the gamma flux per neutron near TFTR. We report here the effects of this increased radiation on the TFTR diagnostic set. The most noticeable effects are luminescence and transmission losses in fiber optic signal cables. In addition, a plastic fiber near the torus became unusably opaque after a few DT discharges. Silicon detectors show signs of neutron interactions as well as gamma response, and microchannel electron multipliers show an increased background due to the gamma flux. Bolometers show n and γ heating, and the Thomson scattering intensifier gate spark gap was unreliable until the gas pressure was adjusted. All of these effects were anticipated, and in some cases shielding or compensation techniques were used. Compensation fibers work satisfactorily at these radiation levels, and the rapid fall-off of the radiation as one moves away from the machine makes relocation of fibers and other sensitive components very useful. Conventional shielding designs worked when streaming through signal penetrations was properly dealt with. In coming DT campaigns and the generation of new tokamaks, such problems will be more severe. JET anticipates higher dose levels per shot during DT; TPX has 1000 s pulses and ITER presents a particularly difficult challenge. We shall discuss the implications of our results for diagnostics on these machines

  20. Nanometer-scale monitoring of quantum-confined Stark effect and emission efficiency droop in multiple GaN/AlN quantum disks in nanowires

    Science.gov (United States)

    Zagonel, L. F.; Tizei, L. H. G.; Vitiello, G. Z.; Jacopin, G.; Rigutti, L.; Tchernycheva, M.; Julien, F. H.; Songmuang, R.; Ostasevicius, T.; de la Peña, F.; Ducati, C.; Midgley, P. A.; Kociak, M.

    2016-05-01

    We report on a detailed study of the intensity dependent optical properties of individual GaN/AlN quantum disks (QDisks) embedded into GaN nanowires (NW). The structural and optical properties of the QDisks were probed by high spatial resolution cathodoluminescence (CL) in a scanning transmission electron microscope (STEM). By exciting the QDisks with a nanometric electron beam at currents spanning over three orders of magnitude, strong nonlinearities (energy shifts) in the light emission are observed. In particular, we find that the amount of energy shift depends on the emission rate and on the QDisk morphology (size, position along the NW and shell thickness). For thick QDisks (>4 nm), the QDisk emission energy is observed to blueshift with the increase of the emission intensity. This is interpreted as a consequence of the increase of carriers density excited by the incident electron beam inside the QDisks, which screens the internal electric field and thus reduces the quantum confined Stark effect (QCSE) present in these QDisks. For thinner QDisks (energy shifts, marking the transition from unscreened to partially screened QCSE. From the threshold value we estimate the lifetime in the unscreened regime. These observations suggest that, counterintuitively, electrons of high energy can behave ultimately as single electron-hole pair generators. In addition, when we increase the current from 1 to 10 pA the light emission efficiency drops by more than one order of magnitude. This reduction of the emission efficiency is a manifestation of the "efficiency droop" as observed in nitride-based 2D light emitting diodes, a phenomenon tentatively attributed to the Auger effect.

  1. Independent variations of applied voltage and injection current for controlling the quantum-confined Stark effect in an InGaN/GaN quantum-well light-emitting diode.

    Science.gov (United States)

    Chen, Horng-Shyang; Liu, Zhan Hui; Shih, Pei-Ying; Su, Chia-Ying; Chen, Chih-Yen; Lin, Chun-Han; Yao, Yu-Feng; Kiang, Yean-Woei; Yang, C C

    2014-04-07

    A reverse-biased voltage is applied to either device in the vertical configuration of two light-emitting diodes (LEDs) grown on patterned and flat Si (110) substrates with weak and strong quantum-confined Stark effects (QCSEs), respectively, in the InGaN/GaN quantum wells for independently controlling the applied voltage across and the injection current into the p-i-n junction in the lateral configuration of LED operation. The results show that more carrier supply is needed in the LED of weaker QCSE to produce a carrier screening effect for balancing the potential tilt in increasing the forward-biased voltage, when compared with the LED of stronger QCSE. The small spectral shift range in increasing injection current in the LED of weaker QCSE is attributed not only to the weaker QCSE, but also to its smaller device resistance such that a given increment of applied voltage leads to a larger increment of injection current. From a viewpoint of practical application in LED operation, by applying a reverse-biased voltage in the vertical configuration, the applied voltage and injection current in the lateral configuration can be independently controlled by adjusting the vertical voltage for keeping the emission spectral peak fixed.

  2. Systematic Review of the Diagnostic Accuracy and Therapeutic Effectiveness of Sacroiliac Joint Interventions.

    Science.gov (United States)

    Simopoulos, Thomas T; Manchikanti, Laxmaiah; Gupta, Sanjeeva; Aydin, Steve M; Kim, Chong Hwan; Solanki, Daneshvari; Nampiaparampil, Devi E; Singh, Vijay; Staats, Peter S; Hirsch, Joshua A

    2015-01-01

    The sacroiliac joint is well known as a cause of low back and lower extremity pain. Prevalence estimates are 10% to 25% in patients with persistent axial low back pain without disc herniation, discogenic pain, or radiculitis based on multiple diagnostic studies and systematic reviews. However, at present there are no definitive management options for treating sacroiliac joint pain. To evaluate the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. A systematic review of the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. The available literature on diagnostic and therapeutic sacroiliac joint interventions was reviewed. The quality assessment criteria utilized were the Quality Appraisal of Reliability Studies (QAREL) checklist for diagnostic accuracy studies, Cochrane review criteria to assess sources of risk of bias, and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment (IPM-QRB) criteria for randomized therapeutic trials and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment for Nonrandomized Studies (IPM-QRBNR) for observational therapeutic assessments. The level of evidence was based on a best evidence synthesis with modified grading of qualitative evidence from Level I to Level V. Data sources included relevant literature published from 1966 through March 2015 that were identified through searches of PubMed and EMBASE, manual searches of the bibliographies of known primary and review articles, and all other sources. For the diagnostic accuracy assessment, and for the therapeutic modalities, the primary outcome measure of pain relief and improvement in functional status were utilized. A total of 11 diagnostic accuracy studies and 14 therapeutic studies were included. The evidence for diagnostic accuracy is Level II for dual diagnostic blocks with at least 70% pain relief as the criterion

  3. Production of H(2s) fast metastable atoms (0.25-3 keV) on a Cs target. Detection of the α Lyman radiation induced by Stark effect: polarisation. Destruction of H(2s) atoms on an IH target

    International Nuclear Information System (INIS)

    Valance, Antoine.

    1974-01-01

    The production, detection and destruction of the 2S1/2 metastable state of the hydrogen atom were studied. The quasi-resonant charge exchange processes between fast protons and cesium target, in the total cross sections for production of metastable H(2s) atoms and radiative H(2p) atoms showed structures hitherto unobserved. The theoretical study is based on calculation of the adiabatic molecular potential terms of the ionic quasi-molecule (CsH) + , taking a Helmann type pseudopotential to describe the electron with respect to the core of the cesium ion. The probabilities of transition towards the output channels are calculated using a stationary state perturbation method. From the data obtained the interferece phenomena of excited quasi-molecular states can be interpreted coherently in slow collision. The probability of transition along the inelastic output channels displays characteristics of a harmonic oscillatory function inversely proportional to the speed of approach of the particles. The frequency of these oscillations depends very slightly on the impact parameter. The theory proposed involves three Σ states. During detection of the metastable ions the Lyman-α radiation induced in the de-excitation electric field by Stark effect present anisotropic features. The degree of polarization measured as a function of the field strength oscillates around a slow decay toward a limit-1 at strong electric field. A theory not accounting for the hyperfine structure of states mixed by Stark effect showed a double oscillatory structure containing the two frequencies correlated to the 2P1/2 and 2P3/2 states from the 2S1/2 state. Finally the results on the electron detachment reaction between fast metastable atoms and hydroiodic acid target have contributed towards research on polarized proton sources [fr

  4. Effective diagnostic DAQ systems to reduce unnecessary data in KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Taegu, E-mail: glory@nfri.re.kr; Lee, Woongryol; Hong, Jaesic; Park, Kaprai

    2016-11-15

    Highlights: • When plasma shots do not successfully perform during the intended target time, the diagnostics systems continue to record these unusable data, contributing to increasing data size. • To overcome this problem, some KSTAR’s library were upgraded to monitor the plasma status in real-time. • With the real-time information of plasma status, some of the KSTAR diagnostic systems stop the acquisition process of unnecessary data. • We were able to reduce the refuse data of approximately 698 GByte in the KSTAR 7th campaign. • It was a very effective way to store useful data, and it was helpful to analysts after shot. - Abstract: The plasma status of Korea Superconducting Tokamak Advanced Research (KSTAR) is measured by various diagnostics systems. The measured data size has been increasing every year due to increasing plasma pulse lengths, higher diagnostics operating frequencies, the additions of new diagnostic systems, and an increasing number of diagnostics channels. At times, when plasma shots do not successfully perform during the intended target time, the diagnostics systems continue to record these unusable data, contributing to increasing data size. In addition, the analysis time was affected, as these data need to be separated from the relevant data set. To overcome this problem, KSTAR’s Standard Framework (SFW), Real Time Monitoring (RTMON), and Pulse Automation and Scheduling System (PASS) were upgraded to monitor the plasma status in real-time. When the plasma current is less than 200kA, RTMON sends the plasma status information every second to the SFW via EPICS Channel Access. With the real-time information on plasma status, some of the KSTAR diagnostic systems stop the acquisition process of unnecessary data. This paper describes a method for reducing the storage of unnecessary data and its results in the KSTAR 7th campaign.

  5. Cost-Effectiveness Analysis of Helicobacter pylori Diagnostic Methods in Patients with Atrophic Gastritis

    Directory of Open Access Journals (Sweden)

    Fumio Omata

    2017-01-01

    Full Text Available Background. There are several diagnostic methods for Helicobacter pylori (H. pylori infection. A cost-effective analysis is needed to decide on the optimal diagnostic method. The aim of this study was to determine a cost-effective diagnostic method in patients with atrophic gastritis (AG. Methods. A decision-analysis model including seven diagnostic methods was constructed for patients with AG diagnosed by esophagogastroduodenoscopy. Expected values of cost and effectiveness were calculated for each test. Results. If the prevalence of H. pylori in the patients with AG is 85% and CAM-resistant H. pylori is 30%, histology, stool H. pylori antigen (SHPAg, bacterial culture (BC, and urine H. pylori antibody (UHPAb were dominated by serum H. pylori IgG antibody (SHPAb, rapid urease test (RUT, and urea breath test (UBT. Among three undominated methods, the incremental cost-effective ratios (ICER of RUT versus SHPAb and UBT versus RUT were $214 and $1914, respectively. If the prevalence of CAM-sensitive H. pylori was less than 55%, BC was not dominated, but its H. pylori eradication success rate was 0.86. Conclusions. RUT was the most cost-effective at the current prevalence of CAM-resistant H. pylori. BC could not be selected due to its poor effectiveness even if CAM-resistant H. pylori was more than 45%.

  6. Effect of extended scope physiotherapists assessments in orthopaedic diagnostic setting: a systematic review

    DEFF Research Database (Denmark)

    Trøstrup, Jeanette; Juhl, Carsten Bogh; Mikkelsen, Lone Ramer

    2017-01-01

    Background Patients with musculoskeletal diseases can potentially be assessed by an extended scope physiotherapist (ESP) instead of by an orthopaedic surgeon (OS). Objectives To evaluate the effectiveness of the diagnostic musculoskeletal assessment performed by ESP compared to OS. Data sources...... and satisfaction in studies with high, moderate and low risk of bias. Limitations Risk of bias in the included studies. Conclusion and implication of key findings Diagnostic assessments performed by ESP may be as beneficial as or even better than assessment performed by OSs in terms diagnostic agreement, costs...... and satisfaction. However, the methodological quality was generally too low to determine the clear effectiveness of ESP assessment, and more high quality studies are needed....

  7. A new species of Neoperla from China, with a redescription of the female of N. mnong Stark, 1987 (Plecoptera, Perlidae).

    Science.gov (United States)

    Chen, Zhi-Teng; Du, Yu-Zhou

    2016-01-01

    A new species of the Neoperla clymene group (Plecoptera, Perlidae), Neoperla chebalinga sp. n. from Guangdong Province of southern China is described, illustrated, and compared with related taxa. The new species is characterized by the slender aedeagal tube, strongly sclerotized dorsally, and weakly sclerotized ventrally with an upcurved, medial, finger-like membranous lobe. Additionally the aedeagal sac gradually tapers to a blunt apex with a dorsoapical patch of spines. A supplementary description of the female of Neoperla mnong Stark, 1987 from Guangdong Province, China is also given.

  8. Theoretical Stark broadening parameters for spectral lines arising from the 2p5ns, 2p5np and 2p5nd electronic configurations of Mg III

    Science.gov (United States)

    Colón, C.; Moreno-Díaz, C.; Alonso-Medina, A.

    2013-10-01

    In the present work we report theoretical Stark widths and shifts calculated using the Griem semi-empirical approach, corresponding to 237 spectral lines of Mg III. Data are presented for an electron density of 1017 cm-3 and temperatures T = 0.5-10.0 (104K). The matrix elements used in these calculations have been determined from 23 configurations of Mg III: 2s22p6, 2s22p53p, 2s22p54p, 2s22p54f and 2s22p55f for even parity and 2s22p5ns (n = 3-6), 2s22p5nd (n = 3-9), 2s22p55g and 2s2p6np (n = 3-8) for odd parity. For the intermediate coupling (IC) calculations, we use the standard method of least-squares fitting from experimental energy levels by means of the Cowan computer code. Also, in order to test the matrix elements used in our calculations, we present calculated values of 70 transition probabilities of Mg III spectral lines and 14 calculated values of radiative lifetimes of Mg III levels. There is good agreement between our calculations and experimental radiative lifetimes. Spectral lines of Mg III are relevant in astrophysics and also play an important role in the spectral analysis of laboratory plasma. Theoretical trends of the Stark broadening parameter versus the temperature for relevant lines are presented. No values of Stark parameters can be found in the bibliography.

  9. A new species of Neoperla from China, with a redescription of the female of N. mnong Stark, 1987 (Plecoptera, Perlidae

    Directory of Open Access Journals (Sweden)

    Zhi-Teng Chen

    2016-09-01

    Full Text Available A new species of the Neoperla clymene group (Plecoptera, Perlidae, N. chebalinga sp. n. from Guangdong Province of southern China is described, illustrated, and compared with related taxa. The new species is characterized by the slender aedeagal tube, strongly sclerotized dorsally, and weakly sclerotized ventrally with an upcurved, medial, finger-like membranous lobe. Additionally the aedeagal sac gradually tapers to a blunt apex with a dorsoapical patch of spines. A supplementary description of the female of N. mnong Stark, 1987 from Guangdong Province, China is also given.

  10. Whole exome sequencing in neurogenetic odysseys: An effective, cost- and time-saving diagnostic approach.

    Directory of Open Access Journals (Sweden)

    Marta Córdoba

    Full Text Available Diagnostic trajectories for neurogenetic disorders frequently require the use of considerable time and resources, exposing patients and families to so-called "diagnostic odysseys". Previous studies have provided strong evidence for increased diagnostic and clinical utility of whole-exome sequencing in medical genetics. However, specific reports assessing its utility in a setting such as ours- a neurogeneticist led academic group serving in a low-income country-are rare.To assess the diagnostic yield of WES in patients suspected of having a neurogenetic condition and explore the cost-effectiveness of its implementation in a research group located in an Argentinean public hospital.This is a prospective study of the clinical utility of WES in a series of 40 consecutive patients selected from a Neurogenetic Clinic of a tertiary Hospital in Argentina. We evaluated patients retrospectively for previous diagnostic trajectories. Diagnostic yield, clinical impact on management and economic diagnostic burden were evaluated.We demonstrated the clinical utility of Whole Exome Sequencing in our patient cohort, obtaining a diagnostic yield of 40% (95% CI, 24.8%-55.2% among a diverse group of neurological disorders. The average age at the time of WES was 23 (range 3-70. The mean time elapsed from symptom onset to WES was 11 years (range 3-42. The mean cost of the diagnostic workup prior to WES was USD 1646 (USD 1439 to 1853, which is 60% higher than WES cost in our center.WES for neurogenetics proved to be an effective, cost- and time-saving approach for the molecular diagnosis of this heterogeneous and complex group of patients.

  11. The clinician's guide to diagnostic imaging: Cost-effective pathways. Second edition

    International Nuclear Information System (INIS)

    Grossman, Z.D.; Chew, F.S.; Ellis, D.A.; Brigham, S.C.

    1987-01-01

    The authors developed a cost-effective approach to imaging studies, based on initial selection of an exam that best addresses the specific clinical problem and obviates the need for additional diagnostic tests. Tightly reasoned arguments compare available imaging options with respect to diagnostic yield, feasibility, risk, and cost. To aid the clinician in making cost comparisons, each paper of the Second Edition lists the dollar cost of relevant imaging studies. The Second Edition has been thoroughly revised to reflect the important advances in diagnostic imaging of the past three years, highlighting CT's expanding role in thoracic and abdominal problems, magnetic resonance imaging as a spectacular diagnostic tool for the central nervous system, and the clinical application of many newly-developed radiopharmaceuticals. New chapters cover breast cancer screening, acute spinal trauma, search for primary cancer of unknown origin, acute anuria, blunt chest trauma, new onset seizures, and spinal cord compression from metastases. Other papers have been rewritten for greater clarity and to incorporate new techniques, like dipyridamole stress testing. A glossary and an introduction define and explain the capabilities and limitations of current techniques

  12. Effect Size (Cohen's d of Cognitive Screening Instruments Examined in Pragmatic Diagnostic Accuracy Studies

    Directory of Open Access Journals (Sweden)

    Andrew J. Larner

    2014-07-01

    Full Text Available Background/Aims: Many cognitive screening instruments (CSI are available to clinicians to assess cognitive function. The optimal method comparing the diagnostic utility of such tests is uncertain. The effect size (Cohen's d, calculated as the difference of the means of two groups divided by the weighted pooled standard deviations of these groups, may permit such comparisons. Methods: Datasets from five pragmatic diagnostic accuracy studies, which examined the Mini-Mental State Examination (MMSE, the Mini-Mental Parkinson (MMP, the Six-Item Cognitive Impairment Test (6CIT, the Montreal Cognitive Assessment (MoCA, the Test Your Memory test (TYM, and the Addenbrooke's Cognitive Examination-Revised (ACE-R, were analysed to calculate the effect size (Cohen's d for the diagnosis of dementia versus no dementia and for the diagnosis of mild cognitive impairment versus no dementia (subjective memory impairment. Results: The effect sizes for dementia versus no dementia diagnosis were large for all six CSI examined (range 1.59-1.87. For the diagnosis of mild cognitive impairment versus no dementia, the effect sizes ranged from medium to large (range 0.48-1.45, with MoCA having the largest effect size. Conclusion: The calculation of the effect size (Cohen's d in diagnostic accuracy studies is straightforward. The routine incorporation of effect size calculations into diagnostic accuracy studies merits consideration in order to facilitate the comparison of the relative value of CSI.

  13. Local Electric Field Strength in a Hollow Cathode Determined by Stark Splitting of the 2S Level of Hydrogen Isotopes by Optogalvanic Spectroscopy

    International Nuclear Information System (INIS)

    Perez, C.; Rosa, M. I. de la; Gruetzmacher, K.; Fuentes, L. M.; Gonzalo, A. B.

    2008-01-01

    In this work we present Doppler-free two-photon optogalvanic spectroscopy as a tool to measure the electric field strength in the cathode fall region of a hollow cathode discharge via the Stark splitting of the 2S level of atomic deuterium. The strong electric field strength present in the hollow cathode is determined for various discharge conditions which allows studying the corresponding variations of the cathode fall, and its changes with discharge operation time.

  14. The effect of information types on diagnostic strategies in the information aid

    International Nuclear Information System (INIS)

    Kim, Jong Hyun; Seong, Poong Hyun

    2007-01-01

    Through experiments, this paper investigates the compatibility of information types with the diagnostic strategy in information aid. Compatibility with operator strategies is an important requirement for information aiding systems in nuclear power plants (NPPs). This paper used three typical types of information aids for MCR operators to investigate the effect of the aids on diagnostic strategies: 'alarm (A),' 'hypothesis on faults (H),' and 'hypothesis on faults and expected symptoms (HS).' The experimental results indicate that the effectiveness of information aid types can vary, dependent on the strategies subjects employ. The results also show that the HS aid improved the diagnosis performance in the hypothesis-and-test strategy

  15. Cost-effectiveness of diagnostic-therapeutic strategies for paediatric visceral leishmaniasis in Morocco.

    Science.gov (United States)

    Alonso, Sergi; Tachfouti, Nabil; Najdi, Adil; Sicuri, Elisa; Picado, Albert

    2017-01-01

    Visceral leishmaniasis (VL) is a neglected parasitic disease with a high fatality rate if left untreated. Endemic in Morocco, as well as in other countries in the Mediterranean basin, VL mainly affects children living in rural areas. In Morocco, the direct observation of Leishmania parasites in bone marrow (BM) aspirates is used to diagnose VL and meglumine antimoniate (SB) is the first line of treatment. Less invasive, more efficacious and safer alternatives exist. In this study we estimate the cost-effectiveness of alternative diagnostic-therapeutic algorithms for paediatric VL in Morocco. A decision tree was used to estimate the cost-effectiveness of using BM or rapid diagnostic tests (RDTs) as diagnostic tools and/or SB or two liposomal amphotericin B (L-AmB) regimens: 6-day and 2-day courses to treat VL. Incremental cost-effectiveness ratios, expressed as cost per death averted, were estimated by comparing costs and effectiveness of the alternative algorithms. A threshold analysis evaluated at which price L-AmB became cost-effective compared with current practices. Implementing RDT and/or L-AmB treatments would be cost-effective in Morocco according to the WHO thresholds. Introducing the 6-day course L-AmB, current second-line treatment, would be highly cost-effective if L-AmB price was below US$100/phial. The 2-day L-AmB treatment, current standard treatment of paediatric VL in France, is highly cost-effective, with L-AmB at its market price (US$165/phial). The results of this study should encourage the implementation of RDT and/or short-course L-AmB treatments for paediatric VL management in Morocco and other North African countries.

  16. Decision analysis to complete diagnostic research by closing the gap between test characteristics and cost-effectiveness.

    Science.gov (United States)

    Schaafsma, Joanna D; van der Graaf, Yolanda; Rinkel, Gabriel J E; Buskens, Erik

    2009-12-01

    The lack of a standard methodology in diagnostic research impedes adequate evaluation before implementation of constantly developing diagnostic techniques. We discuss the methodology of diagnostic research and underscore the relevance of decision analysis in the process of evaluation of diagnostic tests. Overview and conceptual discussion. Diagnostic research requires a stepwise approach comprising assessment of test characteristics followed by evaluation of added value, clinical outcome, and cost-effectiveness. These multiple goals are generally incompatible with a randomized design. Decision-analytic models provide an important alternative through integration of the best available evidence. Thus, critical assessment of clinical value and efficient use of resources can be achieved. Decision-analytic models should be considered part of the standard methodology in diagnostic research. They can serve as a valid alternative to diagnostic randomized clinical trials (RCTs).

  17. Cost-effectiveness of diagnostic for malaria in Extra-Amazon Region, Brazil

    Directory of Open Access Journals (Sweden)

    de Oliveira Maria Regina F

    2012-11-01

    Full Text Available Abstract Background Rapid diagnostic tests (RDT for malaria have been demonstrated to be effective and they should replace microscopy in certain areas. Method The cost-effectiveness of five RDT and thick smear microscopy was estimated and compared. Data were collected on Brazilian Extra-Amazon Region. Data sources included the National Malaria Control Programme of the Ministry of Health, the National Healthcare System reimbursement table, laboratory suppliers and scientific literature. The perspective was that of the Brazilian public health system, the analytical horizon was from the start of fever until the diagnostic results provided to patient and the temporal reference was that of year 2010. Two costing methods were produced, based on exclusive-use microscopy or shared-use microscopy. The results were expressed in costs per adequately diagnosed cases in 2010 U.S. dollars. One-way sensitivity analysis was performed considering key model parameters. Results In the cost-effectiveness analysis with exclusive-use microscopy, the RDT CareStart™ was the most cost-effective diagnostic strategy. Microscopy was the most expensive and most effective, with an additional case adequately diagnosed by microscopy costing US$ 35,550.00 in relation to CareStart™. In opposite, in the cost-effectiveness analysis with shared-use microscopy, the thick smear was extremely cost-effective. Introducing into the analytic model with shared-use microscopy a probability for individual access to the diagnosis, assuming a probability of 100% of access for a public health system user to any RDT and, hypothetically, of 85% of access to microscopy, this test saw its effectiveness reduced and was dominated by the RDT CareStart™. Conclusion The analysis of cost-effectiveness of malaria diagnosis technologies in the Brazilian Extra-Amazon Region depends on the exclusive or shared use of the microscopy. Following the assumptions of this study, shared-use microscopy would be

  18. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  19. Role of quantum-confined stark effect on bias dependent photoluminescence of N-polar GaN/InGaN multi-quantum disk amber light emitting diodes

    Science.gov (United States)

    Tangi, Malleswararao; Mishra, Pawan; Janjua, Bilal; Prabaswara, Aditya; Zhao, Chao; Priante, Davide; Min, Jung-Wook; Ng, Tien Khee; Ooi, Boon S.

    2018-03-01

    We study the impact of quantum-confined stark effect (QCSE) on bias dependent micro-photoluminescence emission of the quantum disk (Q-disk) based nanowires light emitting diodes (NWs-LED) exhibiting the amber colored emission. The NWs are found to be nitrogen polar (N-polar) verified using KOH wet chemical etching and valence band spectrum analysis of high-resolution X-ray photoelectron spectroscopy. The crystal structure and quality of the NWs were investigated by high-angle annular dark field - scanning transmission electron microscopy. The LEDs were fabricated to acquire the bias dependent micro-photoluminescence spectra. We observe a redshift and a blueshift of the μPL peak in the forward and reverse bias conditions, respectively, with reference to zero bias, which is in contrast to the metal-polar InGaN well-based LEDs in the literature. Such opposite shifts of μPL peak emission observed for N-polar NWs-LEDs, in our study, are due to the change in the direction of the internal piezoelectric field. The quenching of PL intensity, under the reverse bias conditions, is ascribed to the reduction of electron-hole overlap. Furthermore, the blueshift of μPL emission with increasing excitation power reveals the suppression of QCSE resulting from the photo-generated carriers. Thereby, our study confirms the presence of QCSE for NWs-LEDs from both bias and power dependent μPL measurements. Thus, this study serves to understand the QCSE in N-polar InGaN Q-disk NWs-LEDs and other related wide-bandgap nitride nanowires, in general.

  20. Role of quantum-confined stark effect on bias dependent photoluminescence of N-polar GaN/InGaN multi-quantum disk amber light emitting diodes

    KAUST Repository

    Tangi, Malleswararao

    2018-03-09

    We study the impact of quantum-confined stark effect (QCSE) on bias dependent micro-photoluminescence emission of the quantum disk (Q-disk) based nanowires light emitting diodes (NWs-LED) exhibiting the amber colored emission. The NWs are found to be nitrogen polar (N-polar) verified using KOH wet chemical etching and valence band spectrum analysis of high-resolution X-ray photoelectron spectroscopy. The crystal structure and quality of the NWs were investigated by high-angle annular dark field - scanning transmission electron microscopy. The LEDs were fabricated to acquire the bias dependent micro-photoluminescence spectra. We observe a redshift and a blueshift of the μPL peak in the forward and reverse bias conditions, respectively, with reference to zero bias, which is in contrast to the metal-polar InGaN well-based LEDs in the literature. Such opposite shifts of μPL peak emission observed for N-polar NWs-LEDs, in our study, are due to the change in the direction of the internal piezoelectric field. The quenching of PL intensity, under the reverse bias conditions, is ascribed to the reduction of electron-hole overlap. Furthermore, the blueshift of μPL emission with increasing excitation power reveals the suppression of QCSE resulting from the photo-generated carriers. Thereby, our study confirms the presence of QCSE for NWs-LEDs from both bias and power dependent μPL measurements. Thus, this study serves to understand the QCSE in N-polar InGaN Q-disk NWs-LEDs and other related wide-bandgap nitride nanowires, in general.

  1. Effectiveness of relaxation techniques before diagnostic screening of cancer patients

    Directory of Open Access Journals (Sweden)

    Montserrat Aiger

    2016-07-01

    Full Text Available Psychophysiological arousal was observed in cancer patients during the application of relaxation techniques prior to a diagnostic scan (PET-CT. The aim of the study is twofold: firstly, it is sought to establish whether such techniques can minimize patient arousal before diagnostic screening begins, and secondly to measure which of them are most effective. The dependent variable is electrodermal activity, recording the attentional level and emotional response, and the independent variable comprises the relaxation techniques used, namely Jacobson, breathing and visualization. The 39 patients were split into experimental groups to whom the relaxation techniques (Jacobson, breathing exercises, and visualization were applied before they went for the PET-CT. An activity-module procedure was applied to track electrodermal activity during the relaxation sessions, consisting of instructions, timeout; wait, task; relaxation and end of the recording session. The control group received no relaxation techniques before the PET-CT. Session-end results show that patients who perform relaxation techniques achieve greater attentional focus using Jacobson's technique (M = .212 and enhanced emotional containment using visualization (M = .206. It is concluded that relaxation techniques minimize the state of activation during the waiting period before a diagnostic scan.

  2. Investigation of non thermal effects from the Dα line wings in edge plasmas

    International Nuclear Information System (INIS)

    Marandet, Y.; Godbert-Mouret, L.; Koubiti, M.; Stamm, R.; Capes, H.; Guirlet, R.

    2002-01-01

    The far wings of intense Dα lines measured at the edge of the Tore Supra Tokamak are found to exhibit a power-law behavior. The characteristic exponent is not far from two. Since the low density rules out thermal Stark broadening, we discuss non thermal effects which may arise from the edge plasma drift-wave turbulence. We suggest that both the Stark and the Doppler profile could be affected by the turbulence

  3. Fast-ion transport and neutral beam current drive in ASDEX upgrade

    DEFF Research Database (Denmark)

    Geiger, B.; Weiland, M.; Jacobsen, Asger Schou

    2015-01-01

    The neutral beam current drive efficiency has been investigated in the ASDEX Upgrade tokamak by replacing on-axis neutral beams with tangential off-axis beams. A clear modification of the radial fast-ion profiles is observed with a fast-ion D-alpha diagnostic that measures centrally peaked profiles...... during on-axis injection and outwards shifted profiles during off-axis injection. Due to this change of the fast-ion population, a clear modification of the plasma current profile is predicted but not observed by a motional Stark effect diagnostic. The fast-ion transport caused by MHD activity has been...

  4. Structure induction in diagnostic causal reasoning.

    Science.gov (United States)

    Meder, Björn; Mayrhofer, Ralf; Waldmann, Michael R

    2014-07-01

    Our research examines the normative and descriptive adequacy of alternative computational models of diagnostic reasoning from single effects to single causes. Many theories of diagnostic reasoning are based on the normative assumption that inferences from an effect to its cause should reflect solely the empirically observed conditional probability of cause given effect. We argue against this assumption, as it neglects alternative causal structures that may have generated the sample data. Our structure induction model of diagnostic reasoning takes into account the uncertainty regarding the underlying causal structure. A key prediction of the model is that diagnostic judgments should not only reflect the empirical probability of cause given effect but should also depend on the reasoner's beliefs about the existence and strength of the link between cause and effect. We confirmed this prediction in 2 studies and showed that our theory better accounts for human judgments than alternative theories of diagnostic reasoning. Overall, our findings support the view that in diagnostic reasoning people go "beyond the information given" and use the available data to make inferences on the (unobserved) causal rather than on the (observed) data level. (c) 2014 APA, all rights reserved.

  5. Effects of occupational exposure of X-Ray on hematological parameters of diagnostic technicians

    Science.gov (United States)

    Taqi, Ali H.; Faraj, Kharman A.; Zaynal, Sarah A.; Hameed, Ahmed M.; Mahmood, Abd-Alkader A.

    2018-06-01

    The aim of this study was to identify the effects of long term exposure of X-ray on diagnostic technicians which they work at Kirkuk hospitals through examining some hematological parameters which are white blood cells (WBC), Neutrophils, Lymphocyte, Monocyte, Eosinophil, Basophil, Reactive Lymphocyte, red blood cells (RBC), hemoglobin (Hb), hematocrit (HCT), Mean Cell Volume (MCV), Mean Corpuscular Hemoglobin (MCH), Mean Cell Hemoglobin Concentration (MCHC), Red Cell Distribution Width (RDW), Platelet (PLT). The study included 54 male diagnostic technicians and 54 male healthy controls match with the first group to show any alteration of the hematological parameters. The diagnostic technicians divided into two groups depending on their work experience and hours working per day. The statistical analysis was performed using (Graph-pad) program. Our results showed that the Complete blood cells count (CBC) parameters (Neutrophil, Monocytes, Basophile, MCV, RDW and PLT) significantly (Pgroups of the diagnostic technicians compared with their controls. We concluded that chronic exposure of X-ray can significantly alter some hematological parameters and the number of hours working per day has observable effects on the some hematological parameters. We recommended training and courses about hazard of ionizing radiation should be organized for enhance the healthcare quality of the technicians and to improve their knowledge about benefit of radiation protection tools to protect themselves from any overexposure during the daily life.

  6. Diagnostic Impact and Cost-effectiveness of Whole-Exome Sequencing for Ambulant Children With Suspected Monogenic Conditions.

    Science.gov (United States)

    Tan, Tiong Yang; Dillon, Oliver James; Stark, Zornitza; Schofield, Deborah; Alam, Khurshid; Shrestha, Rupendra; Chong, Belinda; Phelan, Dean; Brett, Gemma R; Creed, Emma; Jarmolowicz, Anna; Yap, Patrick; Walsh, Maie; Downie, Lilian; Amor, David J; Savarirayan, Ravi; McGillivray, George; Yeung, Alison; Peters, Heidi; Robertson, Susan J; Robinson, Aaron J; Macciocca, Ivan; Sadedin, Simon; Bell, Katrina; Oshlack, Alicia; Georgeson, Peter; Thorne, Natalie; Gaff, Clara; White, Susan M

    2017-09-01

    Optimal use of whole-exome sequencing (WES) in the pediatric setting requires an understanding of who should be considered for testing and when it should be performed to maximize clinical utility and cost-effectiveness. To investigate the impact of WES in sequencing-naive children suspected of having a monogenic disorder and evaluate its cost-effectiveness if WES had been available at different time points in their diagnostic trajectory. This prospective study was part of the Melbourne Genomics Health Alliance demonstration project. At the ambulatory outpatient clinics of the Victorian Clinical Genetics Services at the Royal Children's Hospital, Melbourne, Australia, children older than 2 years suspected of having a monogenic disorder were prospectively recruited from May 1 through November 30, 2015, by clinical geneticists after referral from general and subspecialist pediatricians. All children had nondiagnostic microarrays and no prior single-gene or panel sequencing. All children underwent singleton WES with targeted phenotype-driven analysis. The study examined the clinical utility of a molecular diagnosis and the cost-effectiveness of alternative diagnostic trajectories, depending on timing of WES. Of 61 children originally assessed, 44 (21 [48%] male and 23 [52%] female) aged 2 to 18 years (mean age at initial presentation, 28 months; range, 0-121 months) were recruited, and a diagnosis was achieved in 23 (52%) by singleton WES. The diagnoses were unexpected in 8 of 23 (35%), and clinical management was altered in 6 of 23 (26%). The mean duration of the diagnostic odyssey was 6 years, with each child having a mean of 19 tests and 4 clinical genetics and 4 nongenetics specialist consultations, and 26 (59%) underwent a procedure while under general anesthetic for diagnostic purposes. Economic analyses of the diagnostic trajectory identified that WES performed at initial tertiary presentation resulted in an incremental cost savings of A$9020 (US$6838) per

  7. The effect of Er on MSE measurements of q, a new technique for measuring Er, and a test of the neoclassical electric field

    International Nuclear Information System (INIS)

    Zarnstorff, M.C.; Synakowski, E.J.

    1996-10-01

    Previous analysis of motional-Stark Effect (MSE) data to measure the q-profile ignored contributions from the plasma electric field. The MSE measurements are shown to be sensitive to the electric field and require significant corrections for plasmas with large rotation velocities or pressure gradients. MSE measurements from rotating plasmas on the Tokamak Fusion Test Reactor (TFTR) confirm the significance of these corrections and verify their magnitude. Several attractive configurations are considered for future MSE-based diagnostics for measuring the plasma radial electric field. MSE data from TFTR is analyzed to determine the change in the radial electric field between two plasmas. The measured electric field quantitatively agrees with the predictions of neoclassical theory. These results confirm the utility of a MSE electric field measurement

  8. Intellectual property considerations for molecular diagnostic development with emphasis on companion diagnostics.

    Science.gov (United States)

    Glorikian, Harry; Warburg, Richard Jeremy; Moore, Kelly; Malinowski, Jennifer

    2018-02-01

    The development of molecular diagnostics is a complex endeavor, with multiple regulatory pathways to consider and numerous approaches to development and commercialization. Companion diagnostics, devices which are "essential for the safe and effective use of a corresponding drug or diagnostic product" (see U.S. Food & Drug Administration, In Vitro Diagnostics - Companion Diagnostics, U.S. Dept. of Health & Human Services(2016), available at https://www.fda.gov/medicaldevices/productsandmedicalprocedures/invitrodiagnostics/ucm407297.htm ) and complementary diagnostics, which are more broadly associated with a class of drug, are becoming increasingly important as integral components of the implementation of precision medicine. Areas covered: The following article will highlight the intellectual property ('IP') considerations pertinent to molecular diagnostics development with special emphasis on companion diagnostics. Expert opinion/commentary Summary: For all molecular diagnostics, intellectual property (IP) concerns are of paramount concern, whether the device will be marketed only in the United States or abroad. Taking steps to protect IP at each stage of product development is critical to optimize profitability of a diagnostic product. Also the legal framework around IP protection of diagnostic technologies has been changing over the previous few years and can be expected to continue to change in the foreseeable near future, thus, a comprehensive IP strategy should take into account the fact that changes in the law can be expected.

  9. The Effect of Molecular Diagnostics on the Treatment of Glioma.

    Science.gov (United States)

    Bush, Nancy Ann Oberheim; Butowski, Nicholas

    2017-04-01

    This review summarizes the use of molecular diagnostics in glioma and its effect on the development of novel therapeutics and management decisions. Genomic and proteomic profiling of brain tumors has provided significant expansion of our understanding of oncogenesis, characterization, and prognostication of brain tumors. Molecular markers such as MGMT, EGFR, IDH, 1p19q, ATRX, TERT, FGFR-TACC, and BRAF are now being used to classify brain tumors as well as influence management decisions. Several of these markers are also being used as therapeutic targets. We review the use of several molecular diagnostics in gliomas and discuss their impact on drug development and clinical trial design. In the future, molecular characterization based on a specific genomic, proteomic as well as transcriptomes for bioformatics analysis will provide clinicians the ability to rationally select drugs with actionable targets for each patient.

  10. Characterization of hollow cathode fall field strength measured by Doppler-free two-photon optogalvanic spectroscopy via Stark splitting of the 2S level of hydrogen and deuterium

    Energy Technology Data Exchange (ETDEWEB)

    Perez, C; De la Rosa, M I; Gruetzmacher, K, E-mail: concha@opt.uva.e [Universidad de Valladolid, Facultad de Ciencias, 47071 Valladolid (Spain)

    2010-05-01

    Doppler-free two-photon optogalvanic spectroscopy has been applied to measure the strong electric field strength and the cathode fall characteristics of hollow cathode discharges operated in hydrogen and deuterium via the Stark splitting of the 2S level of atomic hydrogen isotopes. In this paper we show similarities and differences in the tendencies of the cathode fall characteristics of hydrogen and deuterium in a wide range of identical discharge parameters.

  11. Characterization of hollow cathode fall field strength measured by Doppler-free two-photon optogalvanic spectroscopy via Stark splitting of the 2S level of hydrogen and deuterium

    International Nuclear Information System (INIS)

    Perez, C; De la Rosa, M I; Gruetzmacher, K

    2010-01-01

    Doppler-free two-photon optogalvanic spectroscopy has been applied to measure the strong electric field strength and the cathode fall characteristics of hollow cathode discharges operated in hydrogen and deuterium via the Stark splitting of the 2S level of atomic hydrogen isotopes. In this paper we show similarities and differences in the tendencies of the cathode fall characteristics of hydrogen and deuterium in a wide range of identical discharge parameters.

  12. Cost-effectiveness of functional cardiac imaging in the diagnostic work-up of coronary heart disease.

    Science.gov (United States)

    Pletscher, Mark; Walker, Simon; Moschetti, Karine; Pinget, Christophe; Wasserfallen, Jean-Blaise; Greenwood, John P; Schwitter, Juerg; Girardin, François R

    2016-07-01

    The aim of this study was to assess the cost-effectiveness of eight common diagnostic work-up strategies for coronary heart disease (CHD) in patients with stable angina symptoms in Switzerland. A decision analytical model was used to perform a cost-effectiveness comparison of eight common multitest strategies to diagnose CHD using combinations of four diagnostic techniques: exercise treadmill test (ETT), single-photon emission computed tomography (SPECT), cardiac magnetic resonance imaging (CMR), and coronary angiography (CA). We used a Markov state transition model to extrapolate the results over a life-time horizon, from a third-party payer perspective. We used a CHD prevalence rate of 39% in patients and a base-case scenario with 60-year-old male patients with intermediate symptom severity Canadian Cardiovascular Society grading of angina pectoris 2 and at least one cardiovascular (CV) risk factor but without a history of myocardial infarction and without need for revascularization. Among the eight work-up strategies, one strategy was dominant, i.e. least costly and most effective: ETT followed by CMR if the ETT result was inconclusive and then CA if the CMR result was positive or inconclusive. The CMR features a favourable balance between false-negative diagnoses, associated with an elevated risk of CV events, and false-positive diagnoses, leading to unnecessary CA and related mortality. Key parameters guiding the diagnostic strategy are the prevalence of CHD in patients with angina symptoms and the diagnostic costs of CA and CMR. Cardiac magnetic resonance imaging appears to be a cost-effective work-up strategy compared with other regimens using SPECT or direct CA. Cardiac magnetic resonance imaging should be more widely recommended as a diagnostic procedure for patients with suspected angina symptoms.

  13. Software for the estimation of organ equivalent and effective doses from diagnostic radiology procedures

    International Nuclear Information System (INIS)

    Osei, Ernest K; Barnett, Rob

    2009-01-01

    Diagnostic radiological imaging such as conventional radiography, fluoroscopy and computed tomography (CT) examinations will continue to provide tremendous benefits in modern healthcare. The benefit derived by the patient should far outweigh the risk associated with a properly conducted imaging examination. Nonetheless, it is very important to be able to quantify the risk associated with any radiological examination of patients, and effective dose has been considered a useful indicator of patient exposure. Quantification of the risks associated with radiological imaging is very important as such information will be helpful to physicians and their patients for comparing risks from various imaging examinations and for making informed decisions whenever there is a need for any radiological imaging. The determination of equivalent and effective doses in diagnostic radiology is of interest as a basis for estimates of risk from medical exposures. In this paper we describe a simple computer program OrgDose, which calculates the doses to 27 organs in the body and then calculates the organ equivalent and effective doses and the risk from various procedures in the radiology department including conventional radiography, fluoroscopy and computed tomography examinations. The program will be a useful tool for the medical and paramedical personnel who are involved with assessing organ and effective doses and risks from diagnostic radiology procedures.

  14. Access to diagnostics in primary care and the impact on a primary care led health service.

    LENUS (Irish Health Repository)

    O'Riordan, M

    2015-02-01

    We undertook a postal survey of GPs to establish their current access to radiological and endoscopic tests. More than one fifth of GPs do not have direct access to abdominal (n = 42, 21.4%) or pelvic (n = 49, 24.6%) ultrasound in the public system. Where access is available public patients have an average 14 week waiting period. In stark contrast in the private system virtually all GPs have direct access (n = 159, 99.2% and n = 156, 98.8% respectively for abdominal and pelvic ultrasound) with an average wait of just over four days. Direct access to CT scan in the public system is available to the minority of GPs, e.g. n = 31, 18.4% for chest scan, in the public system; even where available, there is an average 12 week wait for this. In comparison 151 (88.6%) GPs have access to CT chest scanning in the private sector with an average waiting time of 5.4 working days. Such limited access to diagnostics impacts on the delivery of a quality service.

  15. In-vitro diagnostic devices introduction to current point-of-care diagnostic devices

    CERN Document Server

    Cheng, Chao-Min; Chen, Chien-Fu

    2016-01-01

    Addressing the origin, current status, and future development of point-of-care diagnostics, and serving to integrate knowledge and tools from Analytical Chemistry, Bioengineering, Biomaterials, and Nanotechnology, this book focusses on addressing the collective and combined needs of industry and academia (including medical schools) to effectively conduct interdisciplinary research. In addition to summarizing and detailing developed diagnostic devices, this book will attempt to point out the possible future trends of development for point-of-care diagnostics using both scientifically based research and practical engineering needs with the aim to help novices comprehensively understand the development of point-of-care diagnostics. This includes demonstrating several common but critical principles and mechanisms used in point-of-care diagnostics that address practical needs (e.g., disease or healthcare monitoring) using two well-developed examples so far: 1) blood glucose meters (via electrochemistry); and, 2) p...

  16. Companion diagnostics: a regulatory perspective from the last 5 years of molecular companion diagnostic approvals.

    Science.gov (United States)

    Roscoe, Donna M; Hu, Yun-Fu; Philip, Reena

    2015-01-01

    Companion diagnostics are essential for the safe and effective use of the corresponding therapeutic products. The US FDA has approved a number of companion diagnostics used to select cancer patients for treatment with contemporaneously approved novel therapeutics. The processes of co-development and co-approval of a therapeutic product and its companion diagnostic have been a learning experience that continues to evolve. Using several companion diagnostics as examples, this article describes the challenges associated with the scientific, clinical and regulatory hurdles faced by FDA and industry alike. Taken together, this discussion is intended to assist manufacturers toward a successful companion diagnostics development plan.

  17. Interindividual testing of water-soluble oral contrast media in respect of diagnostic ranking, side effects and taste

    International Nuclear Information System (INIS)

    Staebler, A.; Fink, U.; Siuda, S.; Neville, S.

    1989-01-01

    Three groups of patients (n = 55, 52 and 54) were examined with the X-ray contrast media Gastrografin, Peritrast-Oral GI, and Telebrix Gastro to assess the diagnostic ranking, side effects and taste of watersoluble oral contrast media. No significant differences were seen in respect of diagnostic ranking and side effects. Side effects were exclusively abdominal symptoms; there was no difference with regard to laxative action. Telebrix Gastroas accepted significantly better in respect of taste than Gastrografin and Peritrast-Oral GI. (orig.) [de

  18. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D.

    Science.gov (United States)

    Chen, J; Ding, W X; Brower, D L; Finkenthal, D; Muscatello, C; Taussig, D; Boivin, R

    2016-11-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  19. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

    International Nuclear Information System (INIS)

    Chen, J.; Ding, W. X.; Brower, D. L.; Finkenthal, D.; Muscatello, C.; Taussig, D.; Boivin, R.

    2016-01-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  20. The Effects of Fatigue From Overnight Shifts on Radiology Search Patterns and Diagnostic Performance.

    Science.gov (United States)

    Hanna, Tarek N; Zygmont, Matthew E; Peterson, Ryan; Theriot, David; Shekhani, Haris; Johnson, Jamlik-Omari; Krupinski, Elizabeth A

    2018-01-20

    The aim of this study was to assess the effect of overnight shifts (ONS) on radiologist fatigue, visual search pattern, and diagnostic performance. This experimental study was approved by the institutional review board. Twelve radiologists (five faculty members and seven residents) each completed two sessions: one during a normal workday ("not fatigued") and another in the morning after an ONS ("fatigued"). Each radiologist completed the Swedish Occupational Fatigue Inventory. During each session, radiologists viewed 20 bone radiographs consisting of normal and abnormal findings. Viewing time, diagnostic confidence, and eye-tracking data were recorded. Swedish Occupational Fatigue Inventory results demonstrated worsening in all five variables (lack of energy, physical exertion, physical discomfort, lack of motivation, and sleepiness) after ONS (P radiologists were more fatigued with worse diagnostic performance, a 45% increase in view time per case, a 60% increase in total gaze fixations, and a 34% increase in time to fixate on the fracture. The effects of fatigue were more pronounced in residents. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. Electrophysiological evidence for colour effects on the naming of colour diagnostic and noncolour diagnostic objects

    OpenAIRE

    Bramão, I.; Francisco, A.; Inácio , F.; Faísca, L.; Reis, A.; Petersson, K.

    2012-01-01

    In this study, we investigated the level of visual processing at which surface colour information improves the naming of colour diagnostic and noncolour diagnostic objects. Continuous electroencephalograms were recorded while participants performed a visual object naming task in which coloured and black-and-white versions of both types of objects were presented. The black-and-white and the colour presentations were compared in two groups of event-related potentials (ERPs): (1) The P1 and N1 c...

  2. Proceedings on US-Japan workshop A-56 'irradiation effects on plasma diagnostic equipment'

    International Nuclear Information System (INIS)

    1986-06-01

    This is a collection of abstracts and papers for the US-Japan Workshop A-56 on ''Irradiation Effects on Plasma Diagnostic Equipments'' held at the Institute of Plasma Physics, Nagoya University, on January 28 through 30, 1986. The topics presented at the workshop are classified as follows: 1) Definition of the problems and general views. 2) Radiation levels estimated from recent experiments and analysis on large tokamaks. 3) Radiation sensitivities of diagnostic components. 4) Neutron sources for irradiation testing. 5) Discussion on suggested experiments on radiation hardening and conclusions. The conclusions summarized by Dr. K. M. Young are also included. (author)

  3. Side effects after diagnostic lumbar puncture and lumbar iohexol myelography

    International Nuclear Information System (INIS)

    Sand, T.; Stovner, L.J.; Salvesen, R.; Dale, L.

    1987-01-01

    A prospective, controlled study was performed to compare side effect incidences after lumbar iohexol myelography (n=97) and diagnostic lumbar puncture (n=85). No significant side effect incidence differences (iohexol vs. controls) were found regarding number of patients with any side effect (63 vs. 73%), headache (44 vs. 54%), nausea, dizziness, visual, auditory, or psychic symptoms. Early-onset headache occurred significantly more often in the iohexol group (16 vs 5%), while postural headache occurred most frequently after lumbar puncture (25 vs. 41%). These results suggest that apart from the slight early-onset headache, most side effets after lumbar iohexol myelography are related to the puncture per se, not to the contrast agent. (orig.)

  4. Diagnostic reasoning strategies and diagnostic success.

    Science.gov (United States)

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  5. Diagnostic grand rounds: A new teaching concept to train diagnostic reasoning

    International Nuclear Information System (INIS)

    Stieger, Stefan; Praschinger, Andrea; Kletter, Kurt; Kainberger, Franz

    2011-01-01

    Introduction: Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. Methods: During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. Results: The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Conclusion: Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice.

  6. Diagnostic grand rounds: A new teaching concept to train diagnostic reasoning

    Energy Technology Data Exchange (ETDEWEB)

    Stieger, Stefan, E-mail: stefan.stieger@univie.ac.at [Department of Basic Psychological Research, School of Psychology, University of Vienna, Liebiggasse 5, A-1010 Vienna (Austria); Praschinger, Andrea, E-mail: andrea.praschinger@meduniwien.ac.at [Core Unit for Medical Education (BEMAW), Medical University of Vienna, Spitalgasse 23, BT87, P.O. 10, A-1097 Vienna (Austria); Kletter, Kurt, E-mail: kurt.kletter@meduniwien.ac.at [Department of Nuclear Medicine, General Hospital of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kainberger, Franz, E-mail: franz.kainberger@meduniwien.ac.at [Department of Radiology, General Hospital of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2011-06-15

    Introduction: Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. Methods: During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. Results: The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Conclusion: Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice.

  7. Prostate cancer diagnostics: Clinical challenges and the ongoing need for disruptive and effective diagnostic tools.

    Science.gov (United States)

    Sharma, Shikha; Zapatero-Rodríguez, Julia; O'Kennedy, Richard

    The increased incidence and the significant health burden associated with carcinoma of the prostate have led to substantial changes in its diagnosis over the past century. Despite technological advancements, the management of prostate cancer has become progressively more complex and controversial for both early and late-stage disease. The limitations and potential harms associated with the use of prostate-specific antigen (PSA) as a diagnostic marker have stimulated significant investigation of numerous novel biomarkers that demonstrate varying capacities to detect prostate cancer and can decrease unnecessary biopsies. However, only a few of these markers have been approved for specific clinical settings while the others have not been adequately validated for use. This review systematically and critically assesses ongoing issues and emerging challenges in the current state of prostate cancer diagnostic tools and the need for disruptive next generation tools based on analysis of combinations of these biomarkers to enhance predictive accuracy which will benefit clinical diagnostics and patient welfare. Copyright © 2016. Published by Elsevier Inc.

  8. International differences in health care costs in Europe and the United States: Do these affect the cost-effectiveness of diagnostic strategies for pulmonary embolism?

    International Nuclear Information System (INIS)

    Erkel, A.R. van; Pattynama, P.M.T.; Hout, W.B. van den

    1999-01-01

    The aim of this study was to assess whether potential differences in costs for diagnostic procedures and treatment of pulmonary embolism (PE) among European and U. S. hospitals alter the optimal cost-effective diagnostic strategy for PE. A standardized questionnaire was used to obtain cost data for the diagnosis and treatment of PE in participating European and U. S. hospitals. Costs for diagnostic tests and treatment of PE were then calculated in a standardized manner for all participating hospitals, from the hospital perspective. Costs were used in an existing cost-effectiveness analysis (CEA) model to determine the most cost-effective diagnostic strategy in participating hospitals. There were considerable differences in costs for diagnostic and therapeutic procedures for PE among the participating centers. These differences, however, did not affect the most cost-effective strategy based on incremental cost-effectiveness. In all hospitals the most cost-effective strategy appeared to be ultrasound followed by helical CT. International differences in cost of diagnostic and therapeutic procedures certainly exist and should be considered before applying a published CEA. Nevertheless, despite these cost differences, the diagnostic strategy for PE of ultrasound followed by helical CT appears most cost-effective. (orig.)

  9. Diagnostic tool for structural health monitoring: effect of material nonlinearity and vibro-impact process

    Science.gov (United States)

    Hiwarkar, V. R.; Babitsky, V. I.; Silberschmidt, V. V.

    2013-07-01

    Numerous techniques are available for monitoring structural health. Most of these techniques are expensive and time-consuming. In this paper, vibration-based techniques are explored together with their use as diagnostic tools for structural health monitoring. Finite-element simulations are used to study the effect of material nonlinearity on dynamics of a cracked bar. Additionally, several experiments are performed to study the effect of vibro-impact behavior of crack on its dynamics. It was observed that a change in the natural frequency of the cracked bar due to crack-tip plasticity and vibro-impact behavior linked to interaction of crack faces, obtained from experiments, led to generation of higher harmonics; this can be used as a diagnostic tool for structural health monitoring.

  10. ULTRASONOGRAPHY, AN EFFECTIVE TOOL IN DIAGNOSING PLANTAR FASCIITIS: A SYSTEMATIC REVIEW OF DIAGNOSTIC TRIALS

    Science.gov (United States)

    Wyland, Matthew; Applequist, Lee; Bolowsky, Erin; Klingensmith, Heather; Virag, Isaac

    2016-01-01

    Background Plantar fasciitis (PF) is the most common cause of heel pain that affects 10% of the general population, whether living an athletic or sedentary lifestyle. The most frequent mechanism of injury is an inflammatory response that is caused by repetitive micro trauma. Many techniques are available to diagnose PF, including the use of ultrasonography (US). Purpose The purpose of this study is to systematically review and appraise previously published articles published between the years 2000 and 2015 that evaluated the effectiveness of using US in the process of diagnosing PF, as compared to alternative diagnostic methods. Methods A total of eight databases were searched to systematically review scholarly (peer reviewed) diagnostic and intervention articles pertaining to the ability of US to diagnose PF. Results Using specific key words the preliminary search yielded 264 articles, 10 of which were deemed relevant for inclusion in the study. Two raters independently scored each article using the 15 point modified QUADAS scale. Discussion Six studies compared the diagnostic efficacy of US to another diagnostic technique to diagnose PF, and four studies focused on comparing baseline assessment of plantar fascia before subsequent intervention. The most notable US outcomes measured were plantar fascia thickness, enthesopathy, and hypoechogenicity. Conclusion US was found to be accurate and reliable compared to alternative reference standards like MRI in the diagnosis of PF. The general advantages of US (e.g. cost efficient, ease of administration, non-invasive, limited contraindications) make it a superior diagnostic modality in the diagnosis of PF. US should be considered in rehabilitation clinics to effectively diagnose PF and to accurately monitor improvement in the disease process following rehabilitation interventions. Level of Evidence 1A PMID:27757279

  11. Effect of extended scope physiotherapists assessments in orthopaedic diagnostic setting: a systematic review

    DEFF Research Database (Denmark)

    Trøstrup, Jeanette; Juhl, Carsten Bogh; Mikkelsen, Lone Ramer

    2017-01-01

    Background Patients with musculoskeletal diseases can potentially be assessed by an extended scope physiotherapist (ESP) instead of by an orthopaedic surgeon (OS). Objectives To evaluate the effectiveness of the diagnostic musculoskeletal assessment performed by ESP compared to OS. Data sources M...

  12. Effective doses in diagnostic nuclear medicine in Brazil: Possibilities of optimisation

    International Nuclear Information System (INIS)

    Veslasques de Oliveira, S. M.; Tauhata, L.; Lipsztein, J. L.; Boasquevisque, E. M.

    2006-01-01

    With the aim of analysing protection of patient in diagnostic nuclear medicine, this study present data collected from sixteen nuclear medicine public and private institutions in three regions of the country, namely Northeast, Southeast and South regions 26,782 patients protocols were analysed, 24,371 adults and 2,411 children and teen-ages. Myocardial perfusion and bone imaging were responsible, respectively, for 53% and 23% of all diagnostic procedures. For 3.010 adults with age and weight registered, 96% had more than 40 years and mean weight was (69.9±14.1) kg for both genders. Due to similarities in physical characteristics between Brazilian adults patients and ICRP Reference Man, effective doses were estimated using ICRP conversion factors. For adults, the ratio mean activities per mean weigh was higher for female than male for the majority of procedures. For children and teen-ages, this ratio was higher for younger ages. Protocols should consider mean corporal weight for female and activities may be reduced accordingly. For children and teen-ages, effective doses may be reduced for younger ages. High absolved doses in bone surfaces of children due to 67Ga citrate imaging and bone scintigraphies should be investigated. (Author)

  13. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  14. Electron density measurement in gas discharge plasmas by optical and acoustic methods

    International Nuclear Information System (INIS)

    Biagioni, A.; Anania, M.P.; Bellaveglia, M.; Chiadroni, E.; Giovenale, D. Di; Pirro, G. Di; Ferrario, M.; Pompili, R.; Shpakov, V.; Vaccarezza, C.; Villa, F.; Cianchi, A.; Filippi, F.; Mostacci, A.; Zigler, A.

    2016-01-01

    Plasma density represents a very important parameter for both laser wakefield and plasma wakefield acceleration, which use a gas-filled capillary plasma source. Several techniques can be used to measure the plasma density within a capillary discharge, which are mainly based on optical diagnostic methods, as for example the well-known spectroscopic method using the Stark broadening effect. In this work, we introduce a preliminary study on an alternative way to detect the plasma density, based on the shock waves produced by gas discharge in a capillary. Firstly, the measurements of the acoustic spectral content relative to the laser-induced plasmas by a solid target allowed us to understand the main properties of the acoustic waves produced during this kind of plasma generation; afterwards, we have extended such acoustic technique to the capillary plasma source in order to calibrate it by comparison with the stark broadening method.

  15. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  16. The effect of question format and task difficulty on reasoning strategies and diagnostic performance in Internal Medicine residents.

    Science.gov (United States)

    Heemskerk, Laura; Norman, Geoff; Chou, Sophia; Mintz, Marcy; Mandin, Henry; McLaughlin, Kevin

    2008-11-01

    Previous studies have suggested an association between reasoning strategies and diagnostic success, but the influence on this relationship of variables such as question format and task difficulty, has not been studied. Our objective was to study the association between question format, task difficulty, reasoning strategies and diagnostic success. Study participants were 13 Internal Medicine residents at the University of Calgary. Each was given eight problem-solving questions in four clinical presentations and were randomized to groups that differed only in the question format, such that a question presented as short answer (SA) to the first group was presented as extended matching (EM) to the second group. There were equal numbers of SA/EM questions and straightforward/difficult tasks. Participants performed think-aloud during diagnostic reasoning. Data were analyzed using multiple logistic regression. Question format was associated with reasoning strategies; hypothetico-deductive reasoning being used more frequently on EM questions and scheme-inductive reasoning on SA questions. For SA question, non-analytic reasoning alone was used more frequently to answer straightforward cases than difficult cases, whereas for EM questions no such association was observed. EM format and straightforward task increased the odds of diagnostic success, whereas hypothetico-deductive reasoning was associated with reduced odds of success. Question format and task difficulty both influence diagnostic reasoning strategies and studies that examine the effect of reasoning strategies on diagnostic success should control for these effects. Further studies are needed to investigate the effect of reasoning strategies on performance of different groups of learners.

  17. The impact of new trends in POCTs for companion diagnostics, non-invasive testing and molecular diagnostics.

    Science.gov (United States)

    Huckle, David

    2015-06-01

    Point-of-care diagnostics have been slowly developing over several decades and have taken on a new importance in current healthcare delivery for both diagnostics and development of new drugs. Molecular diagnostics have become a key driver of technology change and opened up new areas in companion diagnostics for use alongside pharmaceuticals and in new clinical approaches such as non-invasive testing. Future areas involving smartphone and other information technology advances, together with new developments in molecular biology, microfluidics and surface chemistry are adding to advances in the market. The focus for point-of-care tests with molecular diagnostic technologies is focused on advancing effective applications.

  18. Cognitive aspect of diagnostic errors.

    Science.gov (United States)

    Phua, Dong Haur; Tan, Nigel C K

    2013-01-01

    Diagnostic errors can result in tangible harm to patients. Despite our advances in medicine, the mental processes required to make a diagnosis exhibits shortcomings, causing diagnostic errors. Cognitive factors are found to be an important cause of diagnostic errors. With new understanding from psychology and social sciences, clinical medicine is now beginning to appreciate that our clinical reasoning can take the form of analytical reasoning or heuristics. Different factors like cognitive biases and affective influences can also impel unwary clinicians to make diagnostic errors. Various strategies have been proposed to reduce the effect of cognitive biases and affective influences when clinicians make diagnoses; however evidence for the efficacy of these methods is still sparse. This paper aims to introduce the reader to the cognitive aspect of diagnostic errors, in the hope that clinicians can use this knowledge to improve diagnostic accuracy and patient outcomes.

  19. The effect of threat of litigation on forensic pathologist diagnostic decision making.

    Science.gov (United States)

    Oliver, William Russell

    2011-12-01

    Recent litigation involving medical examiners has caused concern over certifying deaths. We administered a survey of 716 medical examiners regarding the effects of the threat of litigation. Two hundred twenty-two medical examiners responded (31%). Of those who responded, approximately 13.5% admitted to having modified their diagnostic findings due to threat of litigation, and approximately 32.5% stated these considerations would affect their decisions in the future. Physicians who indicated they had or would modify their diagnoses expressed more concern over the possibility of litigation. Chiefs of services were less likely than staff members to indicate changing diagnoses. Practitioners whose jurisdictions included rural areas were significantly more likely to indicate that litigation considerations would affect their diagnoses in the future, although this was not true with those who had already modified their diagnoses. No correlation was found with elected versus appointed positions, accreditation status, sex, race, geographic location, or board certification. Although very few medical examiners have actually been sued because of their diagnoses, a demonstrated threat of litigation has a substantial effect on diagnostic decision making.

  20. Diagnostic accuracy of organ electrodermal diagnostics | Szopinski ...

    African Journals Online (AJOL)

    Objective. To estimate the diagnostic accuracy as well as the scope of utilisation of a new bio-electronic method of organ diagnostics. Design. Double-blind comparative study of the diagnostic results obtained by means of organ electrodermal diagnostics (OED) and clinical diagnoses, as a criterion standard. Setting.

  1. The diagnostic effects of s-TSH and TRH stimulating test on subclinical thyroid function

    International Nuclear Information System (INIS)

    Lu Shujun; Wang Wenliang; Lu Shuyan; Zheng Linong; Hu Changjun; Fang Xiaozheng; Zheng Huian; Ma Meizhen

    2002-01-01

    The study was carried out to investigate the diagnostic effects of supersensitive TSH on diagnosing subclinical thyroid function with only once s-TSH detection and with TRH stimulating tests. TRH stimulating tests have been undertaken for 90 patients with different thyroid disease and 58 normal subjects. Diagnostic basal levels of s-TSH test in control group, subclinical hyperthyroidism group and subclinical hypothyroidism group were 2.20 +- 1.85 mIU/L, 0.54 +- 0.3 mIU/L and 9.08 +- 6.3 mIU/L, respectively, the levels of subclinical hyperthyroidism and subclinical hypothyroidism group were significantly higher than that of normal subjects group (P s -TSH>30 mIU/L. Dynamic observing of TRH stimulating tests have more effect than that of only once s-TSH detection in diagnosing subclinical thyroid function

  2. Cost-effectiveness of using a molecular diagnostic test to improve preoperative diagnosis of thyroid cancer.

    Science.gov (United States)

    Najafzadeh, Mehdi; Marra, Carlo A; Lynd, Larry D; Wiseman, Sam M

    2012-12-01

    Fine-needle aspiration biopsy (FNAB) is a safe and inexpensive diagnostic procedure for evaluating thyroid nodules.Up to 25% of the results from an FNAB, however, may not be diagnostic or may be indeterminate, leading to a subsequent diagnostic thyroid surgery. A new molecularly based diagnostic test could potentially reduce indeterminate cytological results and, with high accuracy, provide a definitive diagnosis for cancer in thyroid nodules. The aim of the study was to estimate the cost-effectiveness of utilizing a molecular diagnostic (DX) test as an adjunct to FNAB, compared with NoDX, to improve the preoperative diagnosis of thyroid nodules. We constructed a patient-level simulation model to estimate the clinical and economic outcomes of using a DX test compared with current practice (NoDX) for the diagnosis of thyroid nodules. By using a cost-effectiveness framework, we measured incremental clinical benefits in terms of quality-adjusted life-years and incremental costs over a 10-year time horizon. Assuming 95% sensitivity and specificity of the Dx test when used as an adjunct to FNAB, the utilization of the DX test resulted in a gain of 0.046 quality-adjusted life-years (95% confidence interval 0.019-0.078) and a saving of $1087 (95% confidence interval $691-$1533) in direct costs per patient. If the cost of the Dx test is less than $1087 per test, we expect to save quality-adjusted life-years and reduce costs when it is utilized. Sensitivity of the DX test, compared with specificity, had a larger influence on the overall outcomes. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  3. Diagnostic causal reasoning with verbal information.

    Science.gov (United States)

    Meder, Björn; Mayrhofer, Ralf

    2017-08-01

    In diagnostic causal reasoning, the goal is to infer the probability of causes from one or multiple observed effects. Typically, studies investigating such tasks provide subjects with precise quantitative information regarding the strength of the relations between causes and effects or sample data from which the relevant quantities can be learned. By contrast, we sought to examine people's inferences when causal information is communicated through qualitative, rather vague verbal expressions (e.g., "X occasionally causes A"). We conducted three experiments using a sequential diagnostic inference task, where multiple pieces of evidence were obtained one after the other. Quantitative predictions of different probabilistic models were derived using the numerical equivalents of the verbal terms, taken from an unrelated study with different subjects. We present a novel Bayesian model that allows for incorporating the temporal weighting of information in sequential diagnostic reasoning, which can be used to model both primacy and recency effects. On the basis of 19,848 judgments from 292 subjects, we found a remarkably close correspondence between the diagnostic inferences made by subjects who received only verbal information and those of a matched control group to whom information was presented numerically. Whether information was conveyed through verbal terms or numerical estimates, diagnostic judgments closely resembled the posterior probabilities entailed by the causes' prior probabilities and the effects' likelihoods. We observed interindividual differences regarding the temporal weighting of evidence in sequential diagnostic reasoning. Our work provides pathways for investigating judgment and decision making with verbal information within a computational modeling framework. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. MHD marking using the MSE polarimeter optics in ILW JET plasmas

    CERN Document Server

    Reyes Cortes, S.; Alves, D.; Baruzzo, M.; Bernardo, J.; Buratti, P.; Coelho, R.; Challis, C.; Chapman, I.; Hawkes, N.; Hender, T.C.; Hobirk, J.; Joffrin, E.

    2016-01-01

    In this communication we propose a novel diagnostic technique, which uses the collection optics of the JET Motional Stark Effect (MSE) diagnostic, to perform polarimetry marking of observed MHD in high temperature plasma regimes. To introduce the technique, first we will present measurements of the coherence between MSE polarimeter, electron cyclotron emission, and Mirnov coil signals aiming to show the feasibility of the method. The next step consists of measuring the amplitude fluctuation of the raw MSE polarimeter signals, for each MSE channel, following carefully the MHD frequency on Mirnov coil data spectrograms. A variety of experimental examples in JET ITER-Like Wall (ILW) plasmas are presented, providing an adequate picture and interpretation for the MSE optics polarimeter technique.

  5. Evaluation of the effectiveness of gonad protection in diagnostic radiology

    International Nuclear Information System (INIS)

    Kawaura, Chiyo; Aoyama, Takahiko; Koyama, Shuji

    2004-01-01

    In the present study we describes the evaluation of the effectiveness of gonad protection in diagnostic radiology based on the measurement of organ and the effective doses with and without lead clothing to gonads. We devised in-phantom dosimetry system and measured organ and effective doses in x-ray radiography and CT examinations with the new dosimetry system. From the data of organ and the effective doses we assessed the effectiveness of radiological protection by the use of lead clothing to gonads. Although in chest radiography and chest CT examinations, the effectiveness of radiological protection was not found, in the case of hip joint radiography (AP), gonad doses decreased remarkably by using lead clothing. The effectiveness of radiological protection, i.e. the ratio of the decreased dose to the dose value without protection, in testis and ovary were found to be 91.4% and 68.0%, respectively. It was also found that gonad doses observed with and without gonad protection were extremely lower than those of threshold for sterility recommended by the International Commission on Radiological Protection 60 (ICRP Publ. 60). (author)

  6. [Evaluation of the effectiveness of gonad protection in diagnostic radiology].

    Science.gov (United States)

    Kawaura, Chiyo; Aoyama, Takahiko; Koyama, Shuji

    2004-01-01

    In the present study we describe the evaluation of the effectiveness of gonad protection in diagnostic radiology based on the measurement of organ and the effective doses with and without lead clothing to gonads. We devised in-phantom dosimetry system and measured organ and effective doses in x-ray radiography and CT examinations with the new dosimetry system. From the data of organ and the effective doses we assessed the effectiveness of radiological protection by the use of lead clothing to gonads. Although in chest radiography and chest CT examinations, the effectiveness of radiological protection was not found, in the case of hip joint radiography (AP), gonad doses decreased remarkably by using lead clothing. The effectiveness of radiological protection, i.e. the ratio of the decreased dose to the dose value without protection, in testis and ovary were found to be 91.4% and 68.0%, respectively. It was also found that gonad doses observed with and without gonad protection were extremely lower than those of threshold for sterility recommended by the International Commission on Radiological Protection 60 (ICRP Publ. 60).

  7. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  8. Effect of data compression on diagnostic accuracy in digital hand and chest radiography

    Science.gov (United States)

    Sayre, James W.; Aberle, Denise R.; Boechat, Maria I.; Hall, Theodore R.; Huang, H. K.; Ho, Bruce K. T.; Kashfian, Payam; Rahbar, Guita

    1992-05-01

    Image compression is essential to handle a large volume of digital images including CT, MR, CR, and digitized films in a digital radiology operation. The full-frame bit allocation using the cosine transform technique developed during the last few years has been proven to be an excellent irreversible image compression method. This paper describes the effect of using the hardware compression module on diagnostic accuracy in hand radiographs with subperiosteal resorption and chest radiographs with interstitial disease. Receiver operating characteristic analysis using 71 hand radiographs and 52 chest radiographs with five observers each demonstrates that there is no statistical significant difference in diagnostic accuracy between the original films and the compressed images with a compression ratio as high as 20:1.

  9. Diagnostic effectiveness of immunoassays systems for hepatitis C virus in samples from multi-transfusion patients

    International Nuclear Information System (INIS)

    Rivero Jimenez, Rene A; Merlin Linares, Julio C; Blanco de Armas, Madelin; Navea Leyva, Leonor M

    2009-01-01

    Hepatitis C virus (CHV) blood-transmission is a health problem in Cuba and in the world. Some types of diagnostic immunoassays have been developed for the blood certification and in general have a high diagnostic sensitivity and specificity in healthy donors. However, its behavior in samples from multi-transfusion patients could by less effective. To assess the diagnostic effectiveness of the UMELISA HCV third generation Cuban immunoassay (TecnoSUMA, S.A. La Habana), Cuba) in samples from multi-transfusion patients, in parallel, 335 sera from patients were processed by UBI HCV EIA 4.0 (United Biomedical, EE.UU) and UMELISA HCV third generation, and the samples with incongruous results were verified by PCR COBAS AmpliScreen HCV Test, v2 system (Roche, EE.UU.) Comparing the UMELISA HCV third generation system with the UBI HCV EIA 4.0 it was achieved a Sd of 95,8% CI(95%): 92,5-99,15 and a Ed of 100% CI (95%): 99,7-100, with IY: 0,96 (0,93-0,99) with k: 0,0582 ID (95%): 0,9276-0,9888, p = 0,000. Both immunoassay systems were satisfactory for immunodiagnosis of multi-transfusion patients

  10. Neutral Beam Source and Target Plasma for Development of a Local Electric Field Fluctuation Diagnostic

    Science.gov (United States)

    Bakken, M. R.; Burke, M. G.; Fonck, R. J.; Lewicki, B. T.; Rhodes, A. T.; Winz, G. R.

    2016-10-01

    A new diagnostic measuring local E-> (r , t) fluctuations is being developed for plasma turbulence studies in tokamaks. This is accomplished by measuring fluctuations in the separation of the π components in the Hα motional Stark spectrum. Fluctuations in this separation are expected to be Ẽ / ẼEMSE 10-3EMSE 10-3 . In addition to a high throughput, high speed spectrometer, the project requires a low divergence (Ω 0 .5°) , 80 keV, 2.5 A H0 beam and a target plasma test stand. The beam employs a washer-stack arc ion source to achieve a high species fraction at full energy. Laboratory tests of the ion source demonstrate repeatable plasmas with Te 10 eV and ne 1.6 ×1017 m-3, sufficient for the beam ion optics requirements. Te and ne scalings of the ion source plasma are presented with respect to operational parameters. A novel three-phase resonant converter power supply will provide 6 mA/cm2 of 80 keV H0 at the focal plane for pulse lengths up to 15 ms, with low ripple δV / 80 keV 0.05 % at 280 kHz. Diagnostic development and validation tests will be performed on a magnetized plasma test stand with 0.5 T field. The test chamber will utilize a washer-stack arc source to produce a target plasma comparable to edge tokamak plasmas. A bias-plate with programmable power supply will be used to impose Ẽ within the target plasma. Work supported by US DOE Grant DE-FG02-89ER53296.

  11. Development of the Model of the System of Managerial Diagnostics of the Enterprise on the Basis of Improvement of Diagnostic Purposes

    Directory of Open Access Journals (Sweden)

    Grzegorz Pawlowski

    2017-11-01

    Full Text Available The purpose of the article is to develop a model of the system of managerial diagnostics of the enterprise on the basis of the improvement of diagnostic purposes. The developed model of the system of managerial diagnostics of the enterprise is a set of subjects (owners, managers, investors, specialists, etc., objects (management system, resources, technology, methods (a set of methods and means, business indicators and criteria (parameters that, when interacting, provide the achievement (efficient and effective of the diagnostic objectives of the system of the objectives of managerial diagnostics of the enterprise, taking into account the compliance of its competitive strategy of the state of the environment function of direct action (competitors, customers, suppliers, mediators, and other contact audiences in the context of improving the efficiency and developing the management. It is determined that the system of goals of the model of the system of managerial diagnostics of the enterprise (taking into account the ensuring of the compliance of the system of management with strategic goals and tactical tasks form the following key diagnostic objectives that require improvement on the basis of business indicators (parameters, namely: 1 diagnostics of the effectiveness of controlling the internal business processes of the enterprise; 2 diagnostics of the effectiveness of the typical organizational structure of enterprise management; 3 diagnostics of the efficiency of standardization of the work of linear and functional managers and specialists at the enterprise; 4 diagnostics of the enterprise in the areas of vocational education, labor activity and motivation, innovation work and social development; 5 diagnostics of the level of conflict in the team at the enterprise; 6 diagnostics of efficiency of use of information technologies in the management of the enterprise. The prospect of further research in this area is to improve the complex system of

  12. Reducing Diagnostic Errors through Effective Communication: Harnessing the Power of Information Technology

    Science.gov (United States)

    Naik, Aanand Dinkar; Rao, Raghuram; Petersen, Laura Ann

    2008-01-01

    Diagnostic errors are poorly understood despite being a frequent cause of medical errors. Recent efforts have aimed to advance the "basic science" of diagnostic error prevention by tracing errors to their most basic origins. Although a refined theory of diagnostic error prevention will take years to formulate, we focus on communication breakdown, a major contributor to diagnostic errors and an increasingly recognized preventable factor in medical mishaps. We describe a comprehensive framework that integrates the potential sources of communication breakdowns within the diagnostic process and identifies vulnerable steps in the diagnostic process where various types of communication breakdowns can precipitate error. We then discuss potential information technology-based interventions that may have efficacy in preventing one or more forms of these breakdowns. These possible intervention strategies include using new technologies to enhance communication between health providers and health systems, improve patient involvement, and facilitate management of information in the medical record. PMID:18373151

  13. Technical diagnostics of steam turbines

    International Nuclear Information System (INIS)

    Vlckova, B.; Drahy, J.

    1987-01-01

    This paper deals with practical experience in application of technical diagnostics methods to steam turbines, in particular using pedestal and shaft vibration measurements as well as estimation of bearing metal temperature and ultrasound emission signals. An estimation of effectiveness of the diagnostics methods used is given on the basis of experimental investigations made on a 30-MW turbine. (author)

  14. Transformer engineering design, technology, and diagnostics

    CERN Document Server

    Kulkarni, SV

    2012-01-01

    Transformer Engineering: Design, Technology, and Diagnostics, Second Edition helps you design better transformers, apply advanced numerical field computations more effectively, and tackle operational and maintenance issues. Building on the bestselling Transformer Engineering: Design and Practice, this greatly expanded second edition also emphasizes diagnostic aspects and transformer-system interactions. What's New in This Edition Three new chapters on electromagnetic fields in transformers, transformer-system interactions and modeling, and monitoring and diagnostics An extensively revised chap

  15. Regional Diagnostic Reference Levels and Collective Effective Doses from Computed Tomography (CT) Scanners in India

    International Nuclear Information System (INIS)

    Livingstone, R.S.; Dinakaran, P.M.

    2011-01-01

    Diagnostic examinations performed using computed tomography (CT) are on the increase, and the use of this modality needs to be monitored periodically. The aim of this study was to formulate regional diagnostic reference levels (DRLs) and assess collective effective doses from CT scanners in Tamil Nadu, India. In-site CT dose measurements were performed for 127 CT scanners in Tamil Nadu as a part of the Atomic Energy Regulatory Board (AERB) funded project for a period of two years. Regional DRLs were formulated at third quartile level for three CT protocols such as thorax, abdomen and pelvis and were found to be 557 mGy.cm, 521 mGy.cm and 294 mGy.cm, respectively. The collective effective dose in Tamil Nadu was found to be 14.93 man Sv per day. (author)

  16. Measuring of electric fields with laser-induced fluorescence-dip Stark spectroscopy

    NARCIS (Netherlands)

    Wagenaars, E.; Bowden, M.D.; Kroesen, G.M.W.

    2007-01-01

    The electric field is an important quantity in low-pressure gas discharges, driving many fundamental processes. Unfortunately, it is difficult to measure electric field distributions in plasmas directly. The goal of this research was to develop a diagnostic technique to measure electric fields in

  17. A Three-Tier Diagnostic Test to Assess Pre-Service Teachers' Misconceptions about Global Warming, Greenhouse Effect, Ozone Layer Depletion, and Acid Rain

    Science.gov (United States)

    Arslan, Harika Ozge; Cigdemoglu, Ceyhan; Moseley, Christine

    2012-01-01

    This study describes the development and validation of a three-tier multiple-choice diagnostic test, the atmosphere-related environmental problems diagnostic test (AREPDiT), to reveal common misconceptions of global warming (GW), greenhouse effect (GE), ozone layer depletion (OLD), and acid rain (AR). The development of a two-tier diagnostic test…

  18. Black-body radiation effects and light shifts in atomic frequency standards

    Energy Technology Data Exchange (ETDEWEB)

    Pal' chikov, V G; Domnin, Yu S; Novoselov, A V [Institute of Metrology for Time and Space at National Research Institute for Physical-Technical and Radiotechnical Measurements - IMVP GP VNIIFTRI, Mendeleevo, Moscow Region, 141570 (Russian Federation)

    2003-04-01

    A general method is presented for calculating the higher-order terms of series in powers of the black-body radiation field for the Stark-state wavefunctions, dipole transition matrix elements and corresponding frequency shifts of hyperfine splitting in the ground states for Cs and Rb atoms. A numerical method for calculating the light shifts in Sr atoms is described. It is based on the Green function method for summation over all intermediate states and exact Dirac-Fock wavefunctions for the resonant transitions to the first excited s-, p- and d-states. By comparing the calculated Stark shift with results of measurements employing atomic frequency standards, the black-body radiation effects on the ground state are analysed.

  19. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    Science.gov (United States)

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  20. Diagnostics of electric fields in plasmas using Stark spectroscopy of xenon atoms

    NARCIS (Netherlands)

    Bowden, M.D.; Jiang, Tao; Visser, B.; Kroesen, G.M.W.

    2003-01-01

    Plasma breakdown is the process that occurs when a voltage is applied across an electrode gap and the neutral gas in the gap becomes ionized and electrically conducting. The goal of our research is to study breakdown processes experimentally on a sub-nanosecond timescale, so that features of

  1. In-service diagnostics of pumping facilities

    International Nuclear Information System (INIS)

    Jaros, I.

    1987-01-01

    The potential is discussed of technical diagnostics in increasing operating reliability of pumping facilities of conventional and nuclear power plants, and in rationalizing the system of their maintenance. Attention is focused on the selection of diagnostic parameters in which the so-called subjective expert methodology is applied, and on the diagnostic system design. At this stage, the construction of the respective facility and the analysis of the failure rate of its individual assemblies should be considered. The selection of diagnostic means directly depends on the selection of diagnostic parameters and is conditional on other factors, such as availability, cost, technical service, and operator's training. Briefly characterized are Czechoslovak standards assessing the mechanical condition of rotary machines from the measurement of the effective value of the rate of their oscillations. (Z.M.)

  2. Excitonic dynamical Franz-Keldysh effect

    DEFF Research Database (Denmark)

    Nordstrøm, K.B.; Johnsen, Kristinn; Allen, S.J.

    1998-01-01

    The dynamical Franz-Keldysh effect is exposed by exploring near-band-gap absorption in the presence of intense THz electric fields. It bridges the gap between the de Franz-Keldysh effect and multiphoton absorption and competes with the THz ac Stark effect in shifting the energy of the excitonic...... resonance. A theoretical model which includes the strong THz field nonperturbatively via a nonequilibrium Green functions technique is able to describe the dynamical Franz-Keldysh effect in the presence of excitonic absorption....

  3. Assessment of organ equivalent doses and effective doses from diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Park, Sang Hyun

    2003-02-01

    The MIRD-type adult male, female and age 10 phantoms were constructed to evaluate organ equivalent dose and effective dose of patient due to typical diagnostic X-ray examination. These phantoms were constructed with external and internal dimensions of Korean. The X-ray energy spectra were generated with SPEC78. MCNP4B ,the general-purposed Monte Carlo code, was used. Information of chest PA , chest LAT, and abdomen AP diagnostic X-ray procedures was collected on the protocol of domestic hospitals. The results showed that patients pick up approximate 0.02 to 0.18 mSv of effective dose from a single chest PA examination, and 0.01 to 0.19 mSv from a chest LAT examination depending on the ages. From an abdomen AP examination, patients pick up 0.17 to 1.40 mSv of effective dose. Exposure time, organ depth from the entrance surface and X-ray beam field coverage considerably affect the resulting doses. Deviation among medical institutions is somewhat high, and this indicated that medical institutions should interchange their information and the need of education for medical staff. The methodology and the established system can be applied, with some expansion, to dose assessment for other medical procedures accompanying radiation exposure of patients like nuclear medicine or therapeutic radiology

  4. Development of ITER diagnostics: Neutronic analysis and radiation hardness

    Energy Technology Data Exchange (ETDEWEB)

    Vukolov, Konstantin, E-mail: vukolov_KY@nrcki.ru; Borisov, Andrey; Deryabina, Natalya; Orlovskiy, Ilya

    2015-10-15

    Highlights: • Problems of ITER diagnostics caused by neutron radiation from hot DT plasma considered. • Careful neutronic analysis is necessary for ITER diagnostics development. • Effective nuclear shielding for ITER diagnostics in the 11th equatorial port plug proposed. • Requirements for study of radiation hardness of diagnostic elements defined. • Results of optical glasses irradiation tests in a fission reactor given. - Abstract: The paper is dedicated to the problems of ITER diagnostics caused by effects of radiation from hot DT plasma. An effective nuclear shielding must be arranged in diagnostic port plugs to meet the nuclear safety requirements and to provide reliable operation of the diagnostics. This task can be solved with the help of neutronic analysis of the diagnostics environment within the port plugs at the design stage. Problems of neutronic calculations are demonstrated for the 11th equatorial port plug. The numerical simulation includes the calculations of neutron fluxes in the port-plug and in the interspace. Options for nuclear shielding, such as tungsten collimator, boron carbide and water moderators, stainless steel and lead screens are considered. Data on neutron fluxes along diagnostic labyrinths allow to define radiation hardness requirements for the diagnostic components and to specify their materials. Options for windows and lenses materials for optical diagnostics are described. The results of irradiation of flint and silica glasses in nuclear reactor have shown that silica KU-1 and KS-4V retain transparency in visible range after neutron fluence of 10{sup 17} cm{sup −2}. Flints required for achromatic objectives have much less radiation hardness about 5 × 10{sup 14} n/cm{sup 2}.

  5. Stark absorption spectroscopy on the carotenoids bound to B800-820 and B800-850 type LH2 complexes from a purple photosynthetic bacterium, Phaeospirillum molischianum strain DSM120.

    Science.gov (United States)

    Horibe, Tomoko; Qian, Pu; Hunter, C Neil; Hashimoto, Hideki

    2015-04-15

    Stark absorption spectroscopy was applied to clarify the structural differences between carotenoids bound to the B800-820 and B800-850 LH2 complexes from a purple photosynthetic bacterium Phaeospirillum (Phs.) molischianum DSM120. The former complex is produced when the bacteria are grown under stressed conditions of low temperature and dim light. These two LH2 complexes bind carotenoids with similar composition, 10% lycopene and 80% rhodopin, each with the same number of conjugated CC double bonds (n=11). Quantitative classical and semi-quantum chemical analyses of Stark absorption spectra recorded in the carotenoid absorption region reveal that the absolute values of the difference dipole moments |Δμ| have substantial differences (2 [D/f]) for carotenoids bound to either B800-820 or B800-850 complexes. The origin of this striking difference in the |Δμ| values was analyzed using the X-ray crystal structure of the B800-850 LH2 complex from Phs. molischianum DSM119. Semi-empirical molecular orbital calculations predict structural deformations of the major carotenoid, rhodopin, bound within the B800-820 complex. We propose that simultaneous rotations around neighboring CC and CC bonds account for the differences in the 2 [D/f] of the |Δμ| value. The plausible position of the rotation is postulated to be located around C21-C24 bonds of rhodopin. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Screening diagnostic program breast cancer

    International Nuclear Information System (INIS)

    Portnoj, L.M.; Zhakova, I.I.; Budnikova, N.V.; Rukhlyadko, E.D.

    1995-01-01

    The authors propose their screening program for detection of breast cancer. It includes the entire complex of present-day screening diagnostic methods, starting from an original system for the formation of groups at risk of breast cancer and completed by the direct diagnostic model of detection of the condition, oriented at a differentiated approach to the use of mammographic techniques. The proposed organizational and methodologic screening measures are both economic and diagnostically effective, thus meeting the principal requirements to screening programs. Screening of 8541 risk-groups patients helped detect 867 nodular formations, 244 of which were cancer and 623 benign formations. 8 refs., 3 figs.,

  7. Resolution of effects in multi-frequency eddy current data for reliable diagnostics of conductive materials

    DEFF Research Database (Denmark)

    Egorov, Alexander; Kucheryavskiy, Sergey V.; Polyakov, Viktor

    2017-01-01

    The effect of eddy currents is widely used for diagnostics of conductive materials. It allows to create very simple and inexpensive systems for non-destructive measurements. However, the results of the measurements depend on many factors, including first of all, a conductivity of material...

  8. Barytes board: a cost effective radiation barrier material for use in diagnostic x-ray suites

    International Nuclear Information System (INIS)

    Coalter, G.C.; Metcalfe, P.E.

    1987-01-01

    The use of barium based products in protective barrier materials proved successful for many years until their cost of manufacture and increases in labour costs for fixing and stopping saw the introduction of lead ply as the material of choice in diagnostic X-ray suites. Whilst the advantage of sheet lead as a barrier for diagnostic X-rays, where the photoelectric effect predominates is recognised, this precedence is somewhat negated by the high cost of manufacture and delays in supply. Lead lined ply also requires external cladding after erection for an acceptable finish to be obtained. Such cost increases have prompted us to re-evaluate the use of precast barium plaster sheets (Barytes Board) as an alternative barrier material

  9. Radiation doses and correlated late effects in diagnostic radiology

    International Nuclear Information System (INIS)

    Gustafsson, M.

    1980-04-01

    Patient irradiation in diagnostic radiology was estimated from measurements of absorbed doses in different organs, assessment of the energy imparted and retrospective calculations based on literature data. Possible late biological effects, with special aspects on children, were surveyed. The dose to the lens of the eye and the possibility of shielding in carotid angiography was studied as was the absorbed dose to the thyroid gland at cardiac catheterization and angiocardiography in children. Calculations of the mean bone marrow dose and gonad doses were performed in children with chronic skeletal disease revealing large contributions from examinations of organs other than the skeleton. The dose distribution in the breast in mammography was investigated. Comparison of the energy imparted in common roentgen examinations in 1960 and 1975 showed an unexpected low decrease in spite of technical improvements. Reasons for the failing decrease are discussed. The energy imparted to children in urological examinations was reduced significantly due to introduction of high sensitivity screens and omission of dose demanding projections. Contributions to the possible late effects were estimated on the basis of the organ doses assessed. (author)

  10. A study on enforcement effects of radiation safety control regulations for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Sung, Mo IL; Park, Myeong Hwan; Kwon, Duk Moon; Lee, Joon IL

    1999-01-01

    The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipment and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of he respondents realized the importance of the radiation safety control system, but about a half of them revealed that regulations were not well observed in accordance with their purposes. Only 43.9 percent of the respondents took an active part in quality control of radiation. And responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Training for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipment. And management of organizations using diagnostic X-ray equipment have to understand and stress the importance of radiation safety control system. (author)

  11. The Thrombolytic Effect of Diagnostic Ultrasound-Induced Microbubble Cavitation in Acute Carotid Thromboembolism.

    Science.gov (United States)

    Porter, Thomas R; Xie, Feng; Lof, John; Powers, Jeffry; Vignon, Francois; Shi, William; White, Matthew

    2017-08-01

    Acute ischemic stroke is often due to thromboembolism forming over ruptured atherosclerotic plaque in the carotid artery (CA). The presence of intraluminal CA thrombus is associated with a high risk of thromboembolic cerebral ischemic events. The cavitation induced by diagnostic ultrasound high mechanical index (MI) impulses applied locally during a commercially available intravenous microbubble infusion has dissolved intravascular thrombi, especially when using longer pulse durations. The beneficial effects of this in acute carotid thromboembolism is not known. An oversized balloon injury was created in the distal extracranial common CA of 38 porcine carotid arteries. After this, a 70% to 80% stenosis was created in the mid common CA proximal to the injury site using partial balloon inflation. Acute thrombotic CA occlusions were created just distal to the balloon catheter by injecting fresh autologous arterial thrombi. After angiographic documentation of occlusion, the common carotid thrombosis was treated with either diagnostic low MI imaging alone (0.2 MI; Philips S5-1) applied through a tissue mimicking phantom (TMP) or intermittent diagnostic high MI stable cavitation (SC)-inducing impulses with a longer pulse duration (0.8 MI; 20 microseconds' pulse duration) or inertial cavitation (IC) impulses (1.2 MI; 20 microseconds' pulse duration). All treatment times were for 30 minutes. Intravenous ultrasound contrast (2% Definity; Lantheus Medical) was infused during the treatment period. Angiographic recanalization in 4 intracranial and extracranial vessels downstream from the CA occlusion (auricular, ascending pharyngeal, buccinator, and maxillary) was assessed with both magnetic resonance 3-dimensional time-of-flight and phase contrast angiography. All magnetic resonance images were interpreted by an independent neuroradiologist using the thrombolysis in cerebral infarction (TICI) scoring system. By phase contrast angiography, at least mild recanalization (TICI 2a

  12. Exposure from diagnostic nuclear medicine procedures

    International Nuclear Information System (INIS)

    Iacob, O.; Diaconescu, C.; Isac, R.

    2002-01-01

    According to our last national study on population exposures from natural and artificial sources of ionizing radiation, 16% of overall annual collective effective dose represent the contribution of diagnostic medical exposures. Of this value, 92% is due to diagnostic X-ray examinations and only 8% arise from diagnostic nuclear medicine procedures. This small contribution to collective dose is mainly the result of their lower frequency compared to that of the X-ray examinations, doses delivered to patients being, on average, ten times higher. The purpose of this review was to reassess the population exposure from in vivo diagnostic nuclear medicine procedures and to evaluate the temporal trends of diagnostic usage of radiopharmaceuticals in Romania. The current survey is the third one conducted in the last decade. As in the previous ones (1990 and 1995), the contribution of the Radiation Hygiene Laboratories Network of the Ministry of Health and Family in collecting data from nuclear medicine departments in hospitals was very important

  13. Photon acceleration versus frequency-domain interferometry for laser wakefield diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dias, J M; Oliveira e Silva, L; Mendonca, J T [GoLP/Centro de Fisica de Plasmas, Inst. Superior Tecnico, Lisbon (Portugal)

    1998-03-01

    A detailed comparison between the photon acceleration diagnostic technique and the frequency-domain interferometric technique for laser wakefield diagnostics, by using ray-tracing equations is presented here. The dispersion effects on the probe beam and the implications of an arbitrary phase velocity of the plasma wave are discussed for both diagnostic techniques. In the presence of large amplitude plasma wave and long interaction distances significant frequency shifts can be observed. The importance of this effect on the determination of the phase and frequency shifts measurements given by each of the two diagnostic techniques, is also analyzed. The accuracy of both diagnostic techniques is discussed and some of their technical problems are reviewed. (author)

  14. Diagnostic challenges of childhood asthma.

    Science.gov (United States)

    Bakirtas, Arzu

    2017-01-01

    Diagnosis of asthma in childhood is challenging. Both underdiagnosis and overdiagnosis of asthma are important issues. The present review gives information about challenging factors for an accurate diagnosis of childhood asthma. Although underdiagnosis of asthma in childhood has always been the most important diagnostic problem, overdiagnosis of asthma has also been increasingly recognized. This is probably due to diagnosis of asthma based on symptoms and signs alone. Demonstration of variable airflow obstruction by lung function tests is the most common asthma diagnostic tests used in practice and is therefore strongly recommended in children who can cooperate. Recently, an asthma guideline combining the clinical and economic evidences with sensitivity and specificity of diagnostic procedures was developed to improve accuracy of diagnosis and to avoid overdiagnosis. This guideline provided an algorithmic clinical and cost-effective approach and included fractional exhaled nitric oxide measurement as one of the diagnostic tests in addition to lung function. Diagnosis of asthma in children should be made by combining relevant history with at least two confirmatory diagnostic tests whenever possible. Diagnosis based on short-period treatment trials should be limited to young children who are unable to cooperate with these tests.

  15. Cost-effectiveness of malaria microscopy and rapid diagnostic tests versus presumptive diagnosis

    DEFF Research Database (Denmark)

    Batwala, Vincent; Magnussen, Pascal; Hansen, Kristian Schultz

    2011-01-01

    .9) than in low transmission setting (US$1.78). At a willingness to pay of US$2.8, RDT remained cost effective up to a threshold value of the cost of treatment of US$4.7. CONCLUSION: RDT was cost effective in both low and high transmission settings. With a global campaign to reduce the costs of AL and RDT......ABSTRACT: BACKGROUND: Current Uganda National Malaria treatment guidelines recommend parasitological confirmation either by microscopy or rapid diagnostic test (RDT) before treatment with artemether-lumefantrine (AL). However, the cost-effectiveness of these strategies has not been assessed...... departments were enrolled from March 2010 to February 2011. Of these, a random sample of 1,627 was selected to measure additional socio-economic characteristics. Costing was performed following the standard step-down cost allocation and the ingredients approach. Effectiveness was measured as the number...

  16. Prioritic directions of inculcation of diagnostic equipment at NPP

    International Nuclear Information System (INIS)

    Morozov, V.I.

    2000-01-01

    The diagnostic provision creates the conditions for increasing the safety and reliability of the NPP functioning, technical service and maintenance by the actual state. With an account of the large number of the NPP equipment elements, limitedness of financial resources, different technical-economical effect from diagnostics determination of the priority directions for introduction of technical diagnostic means into the operational practice is one of the main factors. The method for determining the above-mentioned priorities is proposed. The main aspects of the method and mathematical models, based on the logical-probabilistic modeling, are presented. The essence of the method consists in ranging the technical-economical effect from introduction of various factors of the diagnostic equipment [ru

  17. The Effect of Hypoallergenic Diagnostic Diet in Adolescents and Adult Patients Suffering from Atopic Dermatitis

    Directory of Open Access Journals (Sweden)

    Jarmila Celakovská

    2012-01-01

    Full Text Available Aim: To evaluate the effect of a diagnostic hypoallergenic diet on the severity of atopic dermatitis in patients over 14 years of age. Materials and Methods: The diagnostic hypoallergenic diet was recommended to patients suffering from atopic dermatitis for a period of 3 weeks. The severity of atopic dermatitis was evaluated at the beginning and at the end of this diet (SCORAD I, SCORAD II and the difference in the SCORAD over this period was statistically evaluated. Results: One hundred and forty-nine patients suffering from atopic dermatitis were included in the study: 108 women and 41 men. The average age of the subjects was 26.03 (SD: 9.6 years, with the ages ranging from a minimum of 14 years to a maximum of 63 years. The mean SCORAD at the beginning of the study (SCORAD I was 32.9 points (SD: 14.1 and the mean SCORAD at the end of the diet (SCORAD II was 25.2 points (SD: 9.99. The difference between SCORAD I and SCORAD II was evaluated with the Wilcoxon signed-rank test. The average decrease of SCORAD was 7.7 points, which was statistically significant (P=.00000. Conclusion: Introduction of the diagnostic hypoallergenic diet may serve as a temporary medical solution" in patients suffering from moderate or severe forms of atopic dermatitis. It is recommended that this diet be used in the diagnostic workup of food allergy.

  18. Evidence synthesis to inform model-based cost-effectiveness evaluations of diagnostic tests: a methodological review of health technology assessments

    Directory of Open Access Journals (Sweden)

    Bethany Shinkins

    2017-04-01

    Full Text Available Abstract Background Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. Methods We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1 what evidence aside from test accuracy was searched for and synthesised, 2 which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3 how/whether threshold effects were explored, 4 how the potential dependency between multiple tests in a pathway was accounted for, and 5 for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. Results The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings

  19. Spontaneous emission of the non-Wiener type

    International Nuclear Information System (INIS)

    Basharov, A. M.

    2011-01-01

    The spontaneous emission of a quantum particle and superradiation of an ensemble of identical quantum particles in a vacuum electromagnetic field with zero photon density are examined under the conditions of significant Stark particle and field interaction. New fundamental effects are established: suppression of spontaneous emission by the Stark interaction, an additional “decay” shift in energy of the decaying level as a consequence of Stark interaction unrelated to the Lamb and Stark level shifts, excitation conservation phenomena in a sufficiently dense ensemble of identical particles and suppression of superradiaton in the decay of an ensemble of excited quantum particles of a certain density. The main equations describing the emission processes under conditions of significant Stark interaction are obtained in the effective Hamiltonian representation of quantum stochastic differential equations. It is proved that the Stark interaction between a single quantum particle and a broadband electromagnetic field is represented as a quantum Poisson process and the stochastic differential equations are of the non-Wiener (generalized Langevin) type. From the examined case of spontaneous emission of a quantum particle, the main rules are formulated for studying open systems in the effective Hamiltonian representation.

  20. Relating faults in diagnostic reasoning with diagnostic errors and patient harm.

    NARCIS (Netherlands)

    Zwaan, L.; Thijs, A.; Wagner, C.; Wal, G. van der; Timmermans, D.R.M.

    2012-01-01

    Purpose: The relationship between faults in diagnostic reasoning, diagnostic errors, and patient harm has hardly been studied. This study examined suboptimal cognitive acts (SCAs; i.e., faults in diagnostic reasoning), related them to the occurrence of diagnostic errors and patient harm, and studied

  1. Effects of Experience and Training on Diagnostic Accuracy.

    Science.gov (United States)

    Brammer, Robert

    The interview process was studied to uncover the relationship of expertise in psychotherapy to the likelihood of accurate diagnosis. Experience and training affect the number of diagnostic questions clinicians ask as compared to personal, family, social, occupational, and history questions; and this in turn affects the accuracy of the diagnoses…

  2. Effect of clinical specialist physiotherapists in orthopaedic diagnostic setting - A systematic review

    DEFF Research Database (Denmark)

    Trøstrup, Jeanette; Mikkelsen, Lone Ramer; Juhl, Carsten

    with advanced clinical competencies; Clinical Specialist Physiotherapists (CSP). The use of CSPs instead of OSs to perform diagnostic assessment of patients with musculoskeletal complaints has been implemented in several countries (1). Earlier systematic reviews have evaluated CSPs effectiveness in diagnosing...... methodological quality where one study of high methodological quality found that CSP-clinics were more expensive than OS-led clinics. Patient satisfaction (n=12) ranged from 77–100 % being satisfied (n=9) with similar satisfaction in studies of low, acceptable and high methodological quality. In three studies...

  3. Cost-effectiveness analysis of introducing malaria diagnostic testing in drug shops

    DEFF Research Database (Denmark)

    Hansen, Kristian Schultz; Clarke, Siân E.; Lal, Sham

    2017-01-01

    Background Private sector drug shops are an important source of malaria treatment in Africa, yet diagnosis without parasitological testing is common among these providers. Accurate rapid diagnostic tests for malaria (mRDTs) require limited training and present an opportunity to increase access...... to correct diagnosis. The present study was a cost-effectiveness analysis of the introduction of mRDTs in Ugandan drug shops. Methods Drug shop vendors were trained to perform and sell subsidised mRDTs and artemisinin-based combination therapies (ACTs) in the intervention arm while vendors offered ACTs...... following presumptive diagnosis of malaria in the control arm. The effect on the proportion of customers with fever ‘appropriately treated of malaria with ACT’ was captured during a randomised trial in drug shops in Mukono District, Uganda. Health sector costs included: training of drug shop vendors...

  4. Improving Diagnostics and Treatments for GWI Females by Accounting for the Effects of PTSD

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-16-1-0552 TITLE: Improving Diagnostics and Treatments for GWI Females by Accounting for the Effects of PTSD PRINCIPAL...entered data with past data collections efforts containing additional psychological and symptom based measures including the 36 Item Short Form...differences in psychological and symptom measures were run between the low trauma control group (HC), and the three classification of GWI: total GWI

  5. Effect of radiologists' diagnostic work-up volume on interpretive performance.

    Science.gov (United States)

    Buist, Diana S M; Anderson, Melissa L; Smith, Robert A; Carney, Patricia A; Miglioretti, Diana L; Monsees, Barbara S; Sickles, Edward A; Taplin, Stephen H; Geller, Berta M; Yankaskas, Bonnie C; Onega, Tracy L

    2014-11-01

    To examine radiologists' screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. In an institutional review board-approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [ FPR false-positive rate ], and cancer detection rate [ CDR cancer detection rate ]). Logistic regression was used to assess the association between the volume of recalled screening mammograms ("own" mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and "any" mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0-50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0-50 mammograms, 32% performed the work-up for 51-125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPR false-positive rate (P = .004), and CDR cancer detection rate (P women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant

  6. Effect of Radiologists’ Diagnostic Work-up Volume on Interpretive Performance

    Science.gov (United States)

    Anderson, Melissa L.; Smith, Robert A.; Carney, Patricia A.; Miglioretti, Diana L.; Monsees, Barbara S.; Sickles, Edward A.; Taplin, Stephen H.; Geller, Berta M.; Yankaskas, Bonnie C.; Onega, Tracy L.

    2014-01-01

    Purpose To examine radiologists’ screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. Materials and Methods In an institutional review board–approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [FPRfalse-positive rate], and cancer detection rate [CDRcancer detection rate]). Logistic regression was used to assess the association between the volume of recalled screening mammograms (“own” mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and “any” mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Results Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0–50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0–50 mammograms, 32% performed the work-up for 51–125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPRfalse-positive rate (P = .004), and CDRcancer detection rate (P work-ups for any radiologist yielded significant increases in FPRfalse-positive rate (P = .011) and CDRcancer detection rate (P

  7. Nonlinear effects in ultrasound fields of diagnostic-type transducers used for kidney stone propulsion: Characterization in water

    International Nuclear Information System (INIS)

    Karzova, M.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Cunitz, B.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Kreider, W.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Bailey, M.; Yuldashev, P.; Andriyakhina, Y.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Sapozhnikov, O.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Khokhlova, V.

    2015-01-01

    Newer imaging and therapeutic ultrasound technologies require higher in situ pressure levels compared to conventional diagnostic values. One example is the recently developed use of focused ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.3 MHz C5-2 array probe is used to deliver the acoustic pushing pulses. The probe comprises 128 elements equally spaced at the 55 mm long convex cylindrical surface with 38 mm radius of curvature. The efficacy of the treatment can be increased by using higher intensity at the focus to provide stronger pushing force; however, nonlinear acoustic saturation can be a limiting factor. In this work nonlinear propagation effects were analyzed for the C5-2 transducer using a combined measurement and modeling approach. Simulations were based on the 3D Westervelt equation; the boundary condition was set to match the focal geometry of the beam as measured at a low power output. Focal waveforms simulated for increased output power levels were compared with the fiber-optic hydrophone measurements and were found in good agreement. It was shown that saturation effects do limit the acoustic pressure in the focal region of the transducer. This work has application to standard diagnostic probes and imaging

  8. Nonlinear effects in ultrasound fields of diagnostic-type transducers used for kidney stone propulsion: Characterization in water

    Energy Technology Data Exchange (ETDEWEB)

    Karzova, M., E-mail: masha@acs366.phys.msu.ru [Laboratoire de Mécanique des Fluides et d’Acoustique, Ecole Centrale de Lyon, 36 Avenue Guy de Collongue, 69134 Ecully (France); Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Cunitz, B.; Kreider, W.; Bailey, M. [Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40" t" h Street, Seattle, WA 98105 (United States); Yuldashev, P.; Andriyakhina, Y. [Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Sapozhnikov, O.; Khokhlova, V. [Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40" t" h Street, Seattle, WA 98105 (United States)

    2015-10-28

    Newer imaging and therapeutic ultrasound technologies require higher in situ pressure levels compared to conventional diagnostic values. One example is the recently developed use of focused ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.3 MHz C5-2 array probe is used to deliver the acoustic pushing pulses. The probe comprises 128 elements equally spaced at the 55 mm long convex cylindrical surface with 38 mm radius of curvature. The efficacy of the treatment can be increased by using higher intensity at the focus to provide stronger pushing force; however, nonlinear acoustic saturation can be a limiting factor. In this work nonlinear propagation effects were analyzed for the C5-2 transducer using a combined measurement and modeling approach. Simulations were based on the 3D Westervelt equation; the boundary condition was set to match the focal geometry of the beam as measured at a low power output. Focal waveforms simulated for increased output power levels were compared with the fiber-optic hydrophone measurements and were found in good agreement. It was shown that saturation effects do limit the acoustic pressure in the focal region of the transducer. This work has application to standard diagnostic probes and imaging.

  9. Effect of clinical specialist physiotherapists in orthopaedic diagnostic setting - A systematic review

    DEFF Research Database (Denmark)

    Trøstrup, Jeanette; Mikkelsen, Lone Ramer; Juhl, Carsten

    Relevance: Patients with musculoskeletal complaints are commonly referred to orthopaedic surgeons (OS) with 20 % of patients in primary care being referred to OS consultation. A high proportion of these referrals is not relevant for surgery and can potentially be managed entirely by physiotherapist...... with advanced clinical competencies; Clinical Specialist Physiotherapists (CSP). The use of CSPs instead of OSs to perform diagnostic assessment of patients with musculoskeletal complaints has been implemented in several countries (1). Earlier systematic reviews have evaluated CSPs effectiveness in diagnosing...... patients with musculoskeletal complaints and concluded that CSPs have the ability to diagnose musculoskeletal conditions (2), however since then more new studies have been published. Purpose: To evaluate the effectiveness of assessment of musculoskeletal complaints performed by CSP compared to OS...

  10. Diagnostic staging laparoscopy in gastric cancer treatment: A cost-effectiveness analysis.

    Science.gov (United States)

    Li, Kevin; Cannon, John G D; Jiang, Sam Y; Sambare, Tanmaya D; Owens, Douglas K; Bendavid, Eran; Poultsides, George A

    2018-05-01

    Accurate preoperative staging helps avert morbidity, mortality, and cost associated with non-therapeutic laparotomy in gastric cancer (GC) patients. Diagnostic staging laparoscopy (DSL) can detect metastases with high sensitivity, but its cost-effectiveness has not been previously studied. We developed a decision analysis model to assess the cost-effectiveness of preoperative DSL in GC workup. Analysis was based on a hypothetical cohort of GC patients in the U.S. for whom initial imaging shows no metastases. The cost-effectiveness of DSL was measured as cost per quality-adjusted life-year (QALY) gained. Drivers of cost-effectiveness were assessed in sensitivity analysis. Preoperative DSL required an investment of $107 012 per QALY. In sensitivity analysis, DSL became cost-effective at a threshold of $100 000/QALY when the probability of occult metastases exceeded 31.5% or when test sensitivity for metastases exceeded 86.3%. The likelihood of cost-effectiveness increased from 46% to 93% when both parameters were set at maximum reported values. The cost-effectiveness of DSL for GC patients is highly dependent on patient and test characteristics, and is more likely when DSL is used selectively where procedure yield is high, such as for locally advanced disease or in detecting peritoneal and superficial versus deep liver lesions. © 2017 Wiley Periodicals, Inc.

  11. Nanobiosensors in diagnostics

    Directory of Open Access Journals (Sweden)

    Alejandro Chamorro-Garcia

    2016-11-01

    Full Text Available Medical diagnosis has been greatly improved thanks to the development of new techniques capable of performing very sensitive detection and quantifying certain parameters. These parameters can be correlated with the presence of specific molecules and their quantity. Unfortunately, these techniques are demanding, expensive, and often complicated. On the other side, progress in other fields of science and technology has contributed to the rapid growth of nanotechnology. Although being an emerging discipline, nanotechnology has raised huge interest and expectations. Most of the enthusiasm comes from new possibilities and properties of nanomaterials. Biosensors (simple, robust, sensitive, cost-effective combined with nanomaterials, also called nanobiosensors, are serving as bridge between advanced detection/diagnostics and daily/routine tests. Here we review some of the latest applications of nanobiosensors in diagnostics field.

  12. Electron beam diagnostics study

    International Nuclear Information System (INIS)

    Garganne, P.

    1989-08-01

    This paper summarizes the results of a study on beam diagnostics, using carbon wire scanners and optical transition radiation (DTR) monitors. The main consideration consists in the material selection, taking their thermal properties and their effect on the beam into account [fr

  13. Slowing and cooling of heavy or light (even with a tiny electric dipole moment) polar molecules using a novel, versatile electrostatic Stark decelerator.

    Science.gov (United States)

    Wang, Qin; Hou, Shunyong; Xu, Liang; Yin, Jianping

    2016-02-21

    To meet some demands for realizing precise measurements of an electric dipole moment of electron (eEDM) and examining cold collisions or cold chemical physics, we have proposed a novel, versatile electrostatic Stark decelerator with an array of true 3D electric potential wells, which are created by a series of horizontally-oriented, U-shaped electrodes with time-sequence controlling high voltages (± HV) and two guiding electrodes with a constant voltage. We have calculated the 2D electric field distribution, the Stark shifts of the four lowest rotational sub-levels of PbF molecules in the X1(2)Π1/2(v = 0) electronic and vibrational ground states as well as the population in the different rotational levels. We have discussed the 2D longitudinal and transverse phase-space acceptances of PbF molecules in our decelerator. Subsequently, we have simulated the dynamic processes of the decelerated PbF molecules using the 3D Monte-Carlo method, and have found that a supersonic PbF beam with a velocity of 300 m s(-1) can be efficiently slowed to about 5 m s(-1), which will greatly enhance the sensitivities to research a parity violation and measure an eEDM. In addition, we have investigated the dependences of the longitudinal velocity spread, longitudinal temperature and bunching efficiency on both the number of guiding stages and high voltages, and found that after bunching, a cold packet of PbF molecules in the J = 7/2, MΩ = -7/4 state with a longitudinal velocity spread of 0.69 m s(-1) (corresponding to a longitudinal temperature of 2.35 mK) will be produced by our high-efficient decelerator, which will generate a high energy-resolution molecular beam for studying cold collision physics. Finally, our novel decelerator can also be used to efficiently slow NO molecules with a tiny electric dipole moment (EDM) of 0.16 D from 315 m s(-1) to 28 m s(-1). It is clear that our proposed new decelerator has a good slowing performance and experimental feasibility as well as wide

  14. Electric-dipole moment of CaF by molecular-beam, laser-rf, double-resonance study of Stark splittings

    International Nuclear Information System (INIS)

    Childs, W.J.; Goodman, L.S.; Nielsen, U.; Pfeufer, V.

    1984-01-01

    The electronic structure of diatomic molecules is much more complex for open-shell sytems (radicals) than for the normal closed-shell systems, and the development of an adequate theoretical understanding will require a substantial upgrading of experimental knowledge in both quality and quantity. The alkaline-earth monohalide family of radicals, with only a single electron outside closed-shell cores, would appear to be a logical starting point for such studies, and there has been a great increase in work in this area in the last few years in spite of the special difficulties of working with free radicals. As the work of measuring the vibrational and rotational structure of the electronic states has become more complete, attention has turned to study of the much weaker spin-rotation and hyperfine interactions. Within the last three years, these interactions have been studied systematically at high precision in the calcium monohalide family with the molecular-beam, laser-rf double-resonance technique. The same method has now been modified and extended to make possible measurement of the electric-dipole moments of these molecules through observation of the Stark splittings of radiofrequency transitions. It is hoped that when considered together, the several types of data will make it possible to understand the ground-state electronic wave functions of these molecules at least qualitatively. 2 figures

  15. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  16. Tune-Based Halo Diagnostics

    International Nuclear Information System (INIS)

    Cameron, Peter

    2003-01-01

    Tune-based halo diagnostics can be divided into two categories -- diagnostics for halo prevention, and diagnostics for halo measurement. Diagnostics for halo prevention are standard fare in accumulators, synchrotrons, and storage rings, and again can be divided into two categories -- diagnostics to measure the tune distribution (primarily to avoid resonances), and diagnostics to identify instabilities (which will not be discussed here). These diagnostic systems include kicked (coherent) tune measurement, phase-locked loop (PLL) tune measurement, Schottky tune measurement, beam transfer function (BTF) measurements, and measurement of transverse quadrupole mode envelope oscillations. We refer briefly to tune diagnostics used at RHIC and intended for the SNS, and then present experimental results. Tune-based diagnostics for halo measurement (as opposed to prevention) are considerably more difficult. We present one brief example of tune-based halo measurement

  17. Combining principles of Cognitive Load Theory and diagnostic error analysis for designing job aids: Effects on motivation and diagnostic performance in a process control task.

    Science.gov (United States)

    Kluge, Annette; Grauel, Britta; Burkolter, Dina

    2013-03-01

    Two studies are presented in which the design of a procedural aid and the impact of an additional decision aid for process control were assessed. In Study 1, a procedural aid was developed that avoids imposing unnecessary extraneous cognitive load on novices when controlling a complex technical system. This newly designed procedural aid positively affected germane load, attention, satisfaction, motivation, knowledge acquisition and diagnostic speed for novel faults. In Study 2, the effect of a decision aid for use before the procedural aid was investigated, which was developed based on an analysis of diagnostic errors committed in Study 1. Results showed that novices were able to diagnose both novel faults and practised faults, and were even faster at diagnosing novel faults. This research contributes to the question of how to optimally support novices in dealing with technical faults in process control. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  18. Diagnostics for FIRE: A Status Report

    International Nuclear Information System (INIS)

    Kenneth M. Young

    2002-01-01

    The mission for the proposed FIRE (Fusion Ignition Research Experiment) device is to ''attain, explore, understand and optimize fusion-dominated plasmas.'' Operation at Q * 5, for 20 sec with a fusion power output of *150 MW is the major goal. Attaining this mission sets demands for plasma measurement that are at least as comprehensive as on present tokamaks, with the additional capabilities needed for control of the plasma and for understanding the effects of the alpha-particles. Because of the planned operation in advanced tokamak scenarios, with steep transport barriers, the diagnostic instrumentation must be able to provide fine spatial and temporal resolution. It must also be able to withstand the impact of the intense neutron and gamma irradiation. There are practical engineering issues of minimizing radiation streaming while providing essential diagnostic access to the plasma. Many components will operate close to the first wall, e.g. ceramics and mineral insulated cable for magnetic diagnostics and mirrors for optical diagnostics; these components must be selected and mounted so that they will operate and survive in fluxes which require special material selection. The measurement requirements have been assessed so that the diagnostics for the FIRE device can be defined. Clearly a better set of diagnostics of alpha-particles than that available for TFTR is essential, since the alpha-particles provide the dominant sources of heating and of instability-drive in the plasma

  19. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  20. Radiation hazards and protection of patient in diagnostic radiology

    International Nuclear Information System (INIS)

    Agarwal, Y.C.; Haldar, P.K.

    1980-01-01

    Biological radiation effects such as somatic certainty effects, somatic stochastic effects and genetic effects are described. Diagnostic radiology, therefore, involves risk to the patient in case of undesirable exposures and in particular to the fetus. Gonad doses in diagnostic radiology which may lead to genetic effects have been found to vary within a wide range. To avoid somatic certainty and to keep genetic effects to a minimum, some suggestions are enumerated. They deal with the choice of technique, proper positioning, use of calibrated equipment and use of techniques like xerography, ultrasonography, thermography etc. (M.G.B.)

  1. Proposed diagnostic criteria for internet addiction.

    Science.gov (United States)

    Tao, Ran; Huang, Xiuqin; Wang, Jinan; Zhang, Huimin; Zhang, Ying; Li, Mengchen

    2010-03-01

    The objective of this study was to develop diagnostic criteria for internet addiction disorder (IAD) and to evaluate the validity of our proposed diagnostic criteria for discriminating non-dependent from dependent internet use in the general population. This study was conducted in three stages: the developmental stage (110 subjects in the survey group; 408 subjects in the training group), where items of the proposed diagnostic criteria were developed and tested; the validation stage (n = 405), where the proposed criteria were evaluated for criterion-related validity; and the clinical stage (n = 150), where the criteria and the global clinical impression of IAD were evaluated by more than one psychiatrist to determine inter-rater reliability. The proposed internet addiction diagnostic criteria consisted of symptom criterion (seven clinical symptoms of IAD), clinically significant impairment criterion (functional and psychosocial impairments), course criterion (duration of addiction lasting at least 3 months, with at least 6 hours of non-essential internet usage per day) and exclusion criterion (exclusion of dependency attributed to psychotic disorders). A diagnostic score of 2 + 1, where the first two symptoms (preoccupation and withdrawal symptoms) and at least one of the five other symptoms (tolerance, lack of control, continued excessive use despite knowledge of negative effects/affects, loss of interests excluding internet, and use of the internet to escape or relieve a dysphoric mood) was established. Inter-rater reliability was 98%. Our findings suggest that the proposed diagnostic criteria may be useful for the standardization of diagnostic criteria for IAD.

  2. Automated diagnostics scoping study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Quadrel, R.W.; Lash, T.A.

    1994-06-01

    The objective of the Automated Diagnostics Scoping Study was to investigate the needs for diagnostics in building operation and to examine some of the current technologies in automated diagnostics that can address these needs. The study was conducted in two parts. In the needs analysis, the authors interviewed facility managers and engineers at five building sites. In the technology survey, they collected published information on automated diagnostic technologies in commercial and military applications as well as on technologies currently under research. The following describe key areas that the authors identify for the research, development, and deployment of automated diagnostic technologies: tools and techniques to aid diagnosis during building commissioning, especially those that address issues arising from integrating building systems and diagnosing multiple simultaneous faults; technologies to aid diagnosis for systems and components that are unmonitored or unalarmed; automated capabilities to assist cause-and-effect exploration during diagnosis; inexpensive, reliable sensors, especially those that expand the current range of sensory input; technologies that aid predictive diagnosis through trend analysis; integration of simulation and optimization tools with building automation systems to optimize control strategies and energy performance; integration of diagnostic, control, and preventive maintenance technologies. By relating existing technologies to perceived and actual needs, the authors reached some conclusions about the opportunities for automated diagnostics in building operation. Some of a building operator`s needs can be satisfied by off-the-shelf hardware and software. Other needs are not so easily satisfied, suggesting directions for future research. Their conclusions and suggestions are offered in the final section of this study.

  3. CRISIS-DIAGNOSTICS IN ANTI-CRISIS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Gavrylenko Valentina

    2018-01-01

    Full Text Available Introduction. In today’s conditions of a changing market environment, uncertainty and risk, one of the main tasks of management is the timely detection of crisis symptoms and the development of measures aimed at preventing their negative impact on the activities of the enterprise. The purpose of this article is to determine the accounting and analytical information for the development of the model KRIZІS-diagnostics and ensure the effectiveness of its functioning in anti-crisis management. Results. The analysis of definition of the concept «KRIZІS-diagnostics» in the scientific literature is carried out. Multi-factor models for assessing the financial status and the diagnostics of enterprises bankruptcy for different countries are presented. The specified classification of management KRIZІS-diagnostics is specified. The stages and tasks of KRIZІS-diagnostics are determined. The sources of information, which are determinants of the early symptoms of the crisis and necessary for KRIZІS-diagnostics are indicated and the characteristic is also given. Qualitative and quantitative indicators that characterize the business processes of the enterprise and can be used to analyze the state of the enterprise in a changing environment for preventing the crisis are determined. Conclusions. This approach of identifying crisis symptoms in business processes is the basis for managing an enterprise to make strategic management decisions in order to prevent a crisis at its early stages. The development of KRIZІS-diagnostics as an information provision for anti-crisis management is the direction of further research.

  4. Diagnostic imaging in pregraduate integrated curricula

    International Nuclear Information System (INIS)

    Kainberger, F.; Kletter, K.

    2007-01-01

    Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

  5. [Diagnostic imaging in pregraduate integrated curricula].

    Science.gov (United States)

    Kainberger, F; Kletter, K

    2007-11-01

    Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula.

  6. Suspected acute pulmonary emboli: cost-effectiveness of chest helical computed tomography versus a standard diagnostic algorithm incorporating ventilation-perfusion scintigraphy

    International Nuclear Information System (INIS)

    Larcos, G.; Chi, K.K.G.; Berry, G.; Westmead Hospital, Sydney, NSW; Shiell, A.

    2000-01-01

    There is a controversy regarding the investigation of patients with suspected acute pulmonary embolism (PE). To compare the cost-effectiveness of alternative methods of diagnosing acute PE, chest helical computed tomography (CT) alone and in combination with venous ultrasound (US) of legs and pulmonary angiography (PA) were compared to a conventional algorithm using ventilation-perfusion (V/Q) scintigraphy supplemented in selected cases by US and PA. A decision-analytical model was constructed to model the costs and effects of the three diagnostic strategies in a hypothetical cohort of 1000 patients each. Transition probabilities were based on published data. Life years gained by each strategy were estimated from published mortality rates. Schedule fees were used to estimate costs. The V/Q protocol is both more expensive and more effective than CT alone resulting in 20.1 additional lives saved at a (discounted) cost of $940 per life year gained. An additional 2.5 lives can be saved if CT replaces V/Q scintigraphy in the diagnostic algorithm but at a cost of $23,905 per life year saved. It resulted that the more effective diagnostic strategies are also more expensive. In patients with suspected PE, the incremental cost-effectiveness of the V/Q based strategy over CT alone is reasonable in comparison with other health interventions. The cost-effectiveness of the supplemented CT strategy is more questionable. Copyright (2000) The Australasian College of Physicians

  7. Vibration Diagnostics as an effective Tool for Testing Engines of Internal Combustion

    Directory of Open Access Journals (Sweden)

    Ferenc Dömötör

    2017-10-01

    Full Text Available There are several methods of automotive diagnostics used in services to detect a large variety of faults and damages of various parts of engines of internal combustion. Undoubtedly, they are effective, but they are simply unable to find all types of mechanical faults occurring during the operation. This is the reason why authors of this paper tried to use a special tool, which has been proven for years for detecting faults of rolling element bearing in rotating machinery. During their research, the authors tried to find valuable results by measuring vibration of various parts of engines. Three items were tested, a Diesel engine and two Otto motors. A large number of measurements have been taken at various speed, at different points, in different directions, with different parameter setup, etc. However, there was one setup which has been applied to all three engines. It is the measurement setup of vibration velocity, in the frequency range of 2 Hz-300 Hz. Valuable consequences have been found regarding the clogging of the air filters and the exhaust systems. As a conclusion the authors expressed their opinion, that, apart from the traditional diagnostic methods used in services, vibration measurements can also be useful, especially for detecting faults of rolling element bearings.

  8. Veterinary Molecular Diagnostics

    NARCIS (Netherlands)

    Roest, H.I.J.; Engelsma, M.Y.; Weesendorp, E.; Bossers, A.; Elbers, A.R.W.

    2017-01-01

    In veterinary molecular diagnostics, samples originating from animals are tested. Developments in the farm animals sector and in our societal attitude towards pet animals have resulted in an increased demand for fast and reliable diagnostic techniques. Molecular diagnostics perfectly matches this

  9. Measures to Improve Diagnostic Safety in Clinical Practice.

    Science.gov (United States)

    Singh, Hardeep; Graber, Mark L; Hofer, Timothy P

    2016-10-20

    Timely and accurate diagnosis is foundational to good clinical practice and an essential first step to achieving optimal patient outcomes. However, a recent Institute of Medicine report concluded that most of us will experience at least one diagnostic error in our lifetime. The report argues for efforts to improve the reliability of the diagnostic process through better measurement of diagnostic performance. The diagnostic process is a dynamic team-based activity that involves uncertainty, plays out over time, and requires effective communication and collaboration among multiple clinicians, diagnostic services, and the patient. Thus, it poses special challenges for measurement. In this paper, we discuss how the need to develop measures to improve diagnostic performance could move forward at a time when the scientific foundation needed to inform measurement is still evolving. We highlight challenges and opportunities for developing potential measures of "diagnostic safety" related to clinical diagnostic errors and associated preventable diagnostic harm. In doing so, we propose a starter set of measurement concepts for initial consideration that seem reasonably related to diagnostic safety and call for these to be studied and further refined. This would enable safe diagnosis to become an organizational priority and facilitate quality improvement. Health-care systems should consider measurement and evaluation of diagnostic performance as essential to timely and accurate diagnosis and to the reduction of preventable diagnostic harm.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  10. Correlation measurements for fusion plasma diagnostics

    International Nuclear Information System (INIS)

    Pazsit, I.

    1995-01-01

    A list of a few methods for plasma diagnostics via fluctuations (noise) analysis of random (both temporally and spatially) system parameters is reviewed. Analogy is drawn with certain noise analysis methods, used in the diagnostics of fission reactors. These methods have been applied also to fusion measurements to some extent. However, the treatment of fusion plasma fluctuations is dominated by an approach that allows for temporal randomness, but assumes periodicity in space. This approach suits well a large class of phenomena such as magnetic fluctuations (MHD effects), but is much less suited to treat localised effects such as turbulence and density fluctuations. This paper discusses the potentials of the former approach, i.e. ordinary noise analysis methods of non-periodic variables in fusion plasma diagnostics. A new recommendation is to use the crossed beam correlation analysis of soft X-ray signals for determining the local short-range correlations in the plasma and to perform a systematic exploration of the plasma spatial correlation structure with that and other methods. 16 refs, 7 figs

  11. Comparison of diagnostic protocols and the equivalent effective dose in renal cancer and herniated lumbar disc

    International Nuclear Information System (INIS)

    Ruiz Perez de Villar, M.J.; Vano Carruana, E.; Lanzos Gonbzalez, E.; Perez Torrubia, A.

    1994-01-01

    Renal cancer (RC) and herniated lumbar disc (HLD) were the two pathologies selected for the study of the diagnostic protocols applied in different centers to determine how their variability is reflected in the effective equivalent dose (EED) and establish the optimal radiological protocol for diagnostic purposes, while using the lowest possible dose. On the basis of 222 case histories, it was observed that the EED resulting from the diagnosis of HLD can vary as much as a factor of 3(6.2-18.9 mSv). Likewise, the EED related to the diagnosis of RC can be modified by a factor of 1.5(32.6-48.3 mSv), depending on the diagnostic protocol employed. It can be considered that the optimal protocol to reach a diagnosis of HLD includes chest x-ray, lumbar spine x-ray and lumbar CT scan, while that required for the diagnosis of RC involves chest x-ray, IVU, abdominal CT scan and digital subtraction angiography. The optimization of the study protocols-especially the reduction of the number of exposures, modernization and quality control of the equipment, among other aspects, can reduce the EED by a factor of 2. (Author)

  12. Investigations of the cathode region of an argon arc plasma by degenerate four-wave mixing laser spectroscopy and optical emission spectroscopy

    International Nuclear Information System (INIS)

    Dzierzega, K; Pokrzywka, B; Pellerin, S

    2004-01-01

    Degenerate four-wave mixing (DFWM) laser spectroscopy was used in local studies of atmospheric pressure argon plasma generated in a free-burning arc. The results of plasma diagnostics using the DFWM method were compared to the results obtained with optical emission measurements. In the cathode region of the arc the maxima of both the DFWM signal and the emission coefficient for the 696.5 nm Ar I line depend on the distance from the cathode tip. This effect proves the departure of the plasma state from local thermal equilibrium (LTE) as it has been reported by many authors. On the other hand the Stark shifts of the 696.5 nm Ar I line determined by the DFWM method in relation to plasma diagnostic results show no deviations from LTE on the arc axis down to 1.0 mm from the cathode tip

  13. Assessment of the radiation risk from diagnostic radiology

    International Nuclear Information System (INIS)

    Streffer, C.; Mueller, W.U.

    1995-01-01

    In any assessment of radiation risks from diagnostic radiology the main concern is the possible induction of cancer. It now appears to be beyond all doubt that ionizing rays invite the development of cancer in humans. The radiation doses encountered in diagnostic radiology generally vary from 1 to 50 mSv. For this dose range, no measured values are available to ascertain cancer risks from ionizing rays. The effects of such doses must therefore be extrapolated from higher dose levels under consideration of given dose-effect relationships. All relevant figures for diagnostic X-ray measures are therefore mathematically determined approximate values. The stochastic radiation risk following non-homogeneous radiation exposure is assessed on the basis of the effective dose. This dose was originally introduced to ascertain the risk from radioactive substances incorporated at the working place. A secondary intention was to trigger further developmental processes in radiation protection. Due to the difficulties previously outlined and the uncertainties surrounding the determination and assessment of the effective dose from diagnostic X-ray procedures, this dose should merely be used for technological refinements and comaprisons of examination procedures. It appears unreasonable that the effective doses determined for the individual examinations are summed up to obtain a collective effective dose and to multiply this with a risk factor so as to give an approximation of the resulting deaths from cancer. A reasonable alternative is to inform patients subjected to X-ray examinations about the associated radiation dose and to estimate form this the magnitude of the probable radiation risk. (orig./MG) [de

  14. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  15. Distortion of plasma diagnostics by an ambient gas

    International Nuclear Information System (INIS)

    Pearlman, J.S.; Matzen, M.K.

    1978-03-01

    The effect of vacuum chamber background gas on the ion measurements of a laser-produced, expanding plasma is studied over a wide range of background gas pressures. Experimental measurements are compared with calculations from a coupled rate equation-hydrodynamics code. The code is then used for a parametric study of the effect of background gas pressure on plasma diagnostic measurements. Charge exchange is found to be an important process in our diagnostics above vacuum chamber pressures of 10 -5 Torr

  16. Challenges for Plasma Diagnostic in a Next Step Device (FIRE)

    International Nuclear Information System (INIS)

    Young, Kenneth M.

    2002-01-01

    The physics program of any next-step tokamak such as FIRE [Fusion Ignition Research Experiment] sets demands for plasma measurement which are at least as comprehensive as on present tokamaks, with the additional capabilities needed for control of the plasma and for understanding the effects of the alpha-particles. The diagnostic instrumentation must be able to provide the fine spatial and temporal resolution required for the advanced tokamak plasma scenarios. It must also be able to overcome the effects of neutron- and gamma-induced electrical noise in ceramic components or detectors, and fluorescence and absorption in optical components. There are practical engineering issues of minimizing radiation streaming while providing essential diagnostic access to the plasma. Many diagnostics will require components at or close to the first wall, e.g., ceramics and MI cable for magnetic diagnostics and mirrors for optical diagnostics; these components must be mounted to operate, and survive, i n fluxes which require special material selection. A better set of diagnostics of alpha-particles than that available for the TFTR [Tokamak Fusion Test Reactor] is essential; it must be qualified well before moving into D-T [deuterim-tritium] experiments. A start has been made to assessing the potential implementation of key diagnostics for the FIRE device. The present status is described

  17. Electric field effects on red chlorophylls, b-carotenes and P700 in cyanobacterial photosystem I complexes.

    NARCIS (Netherlands)

    Frese, R.N.; Palacios, M.A.; Azzizi, A.; van Stokkum, I.H.M.; Kruip, J.; Rögner, M.; Karapetyan, N.V.; Schlodder, E.; van Grondelle, R.; Dekker, J.P.

    2002-01-01

    We have probed the absorption changes due to an externally applied electric field (Stark effect) of Photosystem I (PSI) core complexes from the cyanobacteria Synechocystis sp. PCC 6803, Synechococcus elongatus and Spirulina platensis. The results reveal that the so-called C719 chlorophylls in S.

  18. Portable Diagnostics and Rapid Germination

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, Zachary Spencer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versions of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.

  19. The effect of nonlinear propagation on heating of tissue: A numerical model of diagnostic ultrasound beams

    Science.gov (United States)

    Cahill, Mark D.; Humphrey, Victor F.; Doody, Claire

    2000-07-01

    Thermal safety indices for diagnostic ultrasound beams are calculated under the assumption that the sound propagates under linear conditions. A non-axisymmetric finite difference model is used to solve the KZK equation, and so to model the beam of a diagnostic scanner in pulsed Doppler mode. Beams from both a uniform focused rectangular source and a linear array are considered. Calculations are performed in water, and in attenuating media with tissue-like characteristics. Attenuating media are found to exhibit significant nonlinear effects for finite-amplitude beams. The resulting loss of intensity by the beam is then used as the source term in a model of tissue heating to estimate the maximum temperature rises. These are compared with the thermal indices, derived from the properties of the water-propagated beams.

  20. The effectiveness of diagnostic imaging methods for the assessment of soft tissue and articular disorders of the shoulder and elbow

    Energy Technology Data Exchange (ETDEWEB)

    Shahabpour, M. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: Maryam@shahabpour.uzbrussel; Kichouh, M.; Laridon, E. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium); Gielen, J.L. [Department of Radiology, Universitair Ziekenhuis Antwerpen, Universiteit Antwerpen, Wilrijkstraat 10, 2650 Edegem (Belgium); De Mey, J. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)

    2008-02-15

    There are no clear guidelines for diagnostic imaging of articular and soft tissue pathologies of the shoulder and elbow. Several methods are used, including magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and ultrasound (US). Their cost-effectiveness is still unclear. We performed a meta-analysis of the relevant literature and discussed the role of MR imaging of the shoulder and elbow compared with other diagnostic imaging modalities. For the shoulder impingement syndrome and rotator cuff tears, MRI and US have a comparable accuracy for detection of full-thickness rotator cuff tears. MRA and US might be more accurate for the detection of partial-thickness tears than MRI. Given the large difference in cost of MR and US, ultrasound may be the most cost-effective diagnostic method for identification of full-thickness tears in a specialist hospital setting (Evidence level 3). Both MRA and CT arthrography (CTA) are effective methods for the detection of labrum tears. More recently, multidetector CTA has offered the advantages of thinner slices than with MRA in a shorter examination time. Still, MRA has the advantage towards CTA to directly visualize the affected structures with a better evaluation of extent and location and to detect associated capsuloligamentous injuries. For the elbow pathologies, plain MRI or MRA have the advantage towards CTA to detect occult bone injuries. CTA is better for the assessment of the thin cartilage of the elbow. Both US and MRI are reliable methods to detect chronic epicondylitis; US is more available and far more cost-effective (Evidence level 2). MRA can differentiate complete from partial tears of the medial collateral ligament. US or MRI can detect partial and complete biceps tendon tears and/or bursitis. MRI can provide important diagnostic information in lesions of the ulnar, radial, or median nerve.

  1. Systematic Benchmarking of Diagnostic Technologies for an Electrical Power System

    Science.gov (United States)

    Kurtoglu, Tolga; Jensen, David; Poll, Scott

    2009-01-01

    Automated health management is a critical functionality for complex aerospace systems. A wide variety of diagnostic algorithms have been developed to address this technical challenge. Unfortunately, the lack of support to perform large-scale V&V (verification and validation) of diagnostic technologies continues to create barriers to effective development and deployment of such algorithms for aerospace vehicles. In this paper, we describe a formal framework developed for benchmarking of diagnostic technologies. The diagnosed system is the Advanced Diagnostics and Prognostics Testbed (ADAPT), a real-world electrical power system (EPS), developed and maintained at the NASA Ames Research Center. The benchmarking approach provides a systematic, empirical basis to the testing of diagnostic software and is used to provide performance assessment for different diagnostic algorithms.

  2. Fractures of the distal limb occuring under effective diagnostic anaethesia during equine lameness examination

    OpenAIRE

    Plückhahn, Nina

    2011-01-01

    Fractures of the distal limb occuring during present effect of diagnostic nerve blocks respective intraarticular anesthesia represent rare but severe complications in equine lameness examinations. Due to very poor prognosis most cases in this study resulted in euthanisation of the horse. Several reasons can be claimed to cause fractures. As for the above mentioned fact that total loss of the animal is common due to severity of the fracture, the most important reason is represented by undet...

  3. Soft x-ray virtual diagnostics for tokamak simulations

    Science.gov (United States)

    Kim, J. S.; Zhao, L.; Bogatu, I. N.; In, Y.; Turnbull, A.; Osborne, T.; Maraschek, M.; Comer, K.

    2009-11-01

    The numerical toolset, FAR-TECH Virtual Diagnostic Utility, for generating virtual experimental data based on theoretical models and comparing it with experimental data, has been developed for soft x-ray diagnostics on DIII-D. The virtual (or synthetic) soft x-ray signals for a sample DIII-D discharge are compared with the experimental data. The plasma density and temperature radial profiles needed in the soft x-ray signal modeling are obtained from experimental data, i.e., from Thomson scattering and electron cyclotron emission. The virtual soft x-ray diagnostics for the equilibriums have a good agreement with the experimental data. The virtual diagnostics based on an ideal linear instability also agree reasonably well with the experimental data. The agreements are good enough to justify the methodology presented here for utilizing virtual diagnostics for routine comparison of experimental data. The agreements also motivate further detailed simulations with improved physical models such as the nonideal magnetohydrodynamics contributions (resistivity, viscosity, nonaxisymmetric error fields, etc.) and other nonlinear effects, which can be tested by virtual diagnostics with various stability modeling.

  4. Soft x-ray virtual diagnostics for tokamak simulations

    International Nuclear Information System (INIS)

    Kim, J. S.; Zhao, L.; Bogatu, I. N.; In, Y.; Turnbull, A.; Osborne, T.; Maraschek, M.; Comer, K.

    2009-01-01

    The numerical toolset, FAR-TECH Virtual Diagnostic Utility, for generating virtual experimental data based on theoretical models and comparing it with experimental data, has been developed for soft x-ray diagnostics on DIII-D. The virtual (or synthetic) soft x-ray signals for a sample DIII-D discharge are compared with the experimental data. The plasma density and temperature radial profiles needed in the soft x-ray signal modeling are obtained from experimental data, i.e., from Thomson scattering and electron cyclotron emission. The virtual soft x-ray diagnostics for the equilibriums have a good agreement with the experimental data. The virtual diagnostics based on an ideal linear instability also agree reasonably well with the experimental data. The agreements are good enough to justify the methodology presented here for utilizing virtual diagnostics for routine comparison of experimental data. The agreements also motivate further detailed simulations with improved physical models such as the nonideal magnetohydrodynamics contributions (resistivity, viscosity, nonaxisymmetric error fields, etc.) and other nonlinear effects, which can be tested by virtual diagnostics with various stability modeling.

  5. Improving early cycle economic evaluation of diagnostic technologies.

    Science.gov (United States)

    Steuten, Lotte M G; Ramsey, Scott D

    2014-08-01

    The rapidly increasing range and expense of new diagnostics, compels consideration of a different, more proactive approach to health economic evaluation of diagnostic technologies. Early cycle economic evaluation is a decision analytic approach to evaluate technologies in development so as to increase the return on investment as well as patient and societal impact. This paper describes examples of 'early cycle economic evaluations' as applied to diagnostic technologies and highlights challenges in its real-time application. It shows that especially in the field of diagnostics, with rapid technological developments and a changing regulatory climate, early cycle economic evaluation can have a guiding role to improve the efficiency of the diagnostics innovation process. In the next five years the attention will move beyond the methodological and analytic challenges of early cycle economic evaluation towards the challenge of effectively applying it to improve diagnostic research and development and patient value. Future work in this area should therefore be 'strong on principles and soft on metrics', that is, the metrics that resonate most clearly with the various decision makers in this field.

  6. Effects of using the developing nurses' thinking model on nursing students' diagnostic accuracy.

    Science.gov (United States)

    Tesoro, Mary Gay

    2012-08-01

    This quasi-experimental study tested the effectiveness of an educational model, Developing Nurses' Thinking (DNT), on nursing students' clinical reasoning to achieve patient safety. Teaching nursing students to develop effective thinking habits that promote positive patient outcomes and patient safety is a challenging endeavor. Positive patient outcomes and safety are achieved when nurses accurately interpret data and subsequently implement appropriate plans of care. This study's pretest-posttest design determined whether use of the DNT model during 2 weeks of clinical postconferences improved nursing students' (N = 83) diagnostic accuracy. The DNT model helps students to integrate four constructs-patient safety, domain knowledge, critical thinking processes, and repeated practice-to guide their thinking when interpreting patient data and developing effective plans of care. The posttest scores of students from the intervention group showed statistically significant improvement in accuracy. Copyright 2012, SLACK Incorporated.

  7. Clinical outcomes and cost effectiveness of accelerated diagnostic protocol in a chest pain center compared with routine care of patients with chest pain.

    Science.gov (United States)

    Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi

    2015-01-01

    The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (pdiagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (pdiagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (pdiagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), pdiagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14-0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources.

  8. Worked Examples with Errors: When Self-Explanation Prompts Hinder Learning of Teachers Diagnostic Competences on Problem-Based Learning

    Science.gov (United States)

    Heitzmann, Nicole; Fischer, Frank; Fischer, Martin R.

    2018-01-01

    To diagnose classroom situations is crucial for teachers' everyday practice. The approach of worked examples with errors seems promising to support the diagnosis of classroom situations in student teachers (Stark et al. in "Learn Instr" 21(1):22-33, 2011). To enhance that approach, error-explanation prompts and an adaptable feedback…

  9. A revolution in diagnostic imaging.

    Science.gov (United States)

    Mamula, Paul W

    2003-03-01

    In November 1966, Sandy Koufax, the star left-handed pitcher of the Los Angeles Dodgers, retired after spending his final season coping with traumatic arthritis in his elbow, the compounded effects of a sliding injury to his pitching arm the previous season and 12 years of hard throwing.1 Had his career begun a few years later, he might have been able to benefit from the advances in diagnostic imaging and treatment that were introduced at that time. Modern arthroscopy and computed tomography (CT) did not become available until the mid 1970s,2 and the first elbow reconstruction was done by Frank Jobe, MD, about 10 years after Koufax retired.1 Arthroscopy was first used as a diagnostic tool, but it later became a surgical tool, affecting treatment of knees, then, later, shoulders. Since 1973, when The Physician and Sportsmedicine was launched, we have witnessed a revolution in diagnostic imaging and are continuing to see an evolution of modalities.

  10. Dual processing and diagnostic errors.

    Science.gov (United States)

    Norman, Geoff

    2009-09-01

    In this paper, I review evidence from two theories in psychology relevant to diagnosis and diagnostic errors. "Dual Process" theories of thinking, frequently mentioned with respect to diagnostic error, propose that categorization decisions can be made with either a fast, unconscious, contextual process called System 1 or a slow, analytical, conscious, and conceptual process, called System 2. Exemplar theories of categorization propose that many category decisions in everyday life are made by unconscious matching to a particular example in memory, and these remain available and retrievable individually. I then review studies of clinical reasoning based on these theories, and show that the two processes are equally effective; System 1, despite its reliance in idiosyncratic, individual experience, is no more prone to cognitive bias or diagnostic error than System 2. Further, I review evidence that instructions directed at encouraging the clinician to explicitly use both strategies can lead to consistent reduction in error rates.

  11. The next organizational challenge: finding and addressing diagnostic error.

    Science.gov (United States)

    Graber, Mark L; Trowbridge, Robert; Myers, Jennifer S; Umscheid, Craig A; Strull, William; Kanter, Michael H

    2014-03-01

    Although health care organizations (HCOs) are intensely focused on improving the safety of health care, efforts to date have almost exclusively targeted treatment-related issues. The literature confirms that the approaches HCOs use to identify adverse medical events are not effective in finding diagnostic errors, so the initial challenge is to identify cases of diagnostic error. WHY HEALTH CARE ORGANIZATIONS NEED TO GET INVOLVED: HCOs are preoccupied with many quality- and safety-related operational and clinical issues, including performance measures. The case for paying attention to diagnostic errors, however, is based on the following four points: (1) diagnostic errors are common and harmful, (2) high-quality health care requires high-quality diagnosis, (3) diagnostic errors are costly, and (4) HCOs are well positioned to lead the way in reducing diagnostic error. FINDING DIAGNOSTIC ERRORS: Current approaches to identifying diagnostic errors, such as occurrence screens, incident reports, autopsy, and peer review, were not designed to detect diagnostic issues (or problems of omission in general) and/or rely on voluntary reporting. The realization that the existing tools are inadequate has spurred efforts to identify novel tools that could be used to discover diagnostic errors or breakdowns in the diagnostic process that are associated with errors. New approaches--Maine Medical Center's case-finding of diagnostic errors by facilitating direct reports from physicians and Kaiser Permanente's electronic health record--based reports that detect process breakdowns in the followup of abnormal findings--are described in case studies. By raising awareness and implementing targeted programs that address diagnostic error, HCOs may begin to play an important role in addressing the problem of diagnostic error.

  12. Diagnostic Evaluation of Effective Thyroxine Ratio

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Choi, Sang Jae; Ro, Heung Kyu; Lee, Hong Kyu; Koh, Chang Soon; Lee, Mun Ho

    1975-01-01

    The purpose of the present study is to evaluate the diagnostic value of the ETR test as compared to other thyroid function tests in normal persons, patients with thyroid disorders and patients with alterations of thyroxine-binding proteins. The ETR values were obtained from 35 cases as normal control, 63 hyperthyroid patients, 56 euthyroid patients, 23 hypothyroid patients, 10 pregnant women, 5 women taking oral contraceptive medication, 8 liver cirrhosis patients and 4 nephrotic syndrome patients. The results obtained were as follows. 1) The mean value of ETR obtained from the normal controls was 0.99±0.06. 2) The mean ETR values of various thyroid states were 1.25±0.16 in hyperthyroidism, 0.99±0.08 in euthyroidism and 0.82±0.05 in hypothyroidism and significant difference was found between these groups. 3) Seven out of 63 hyperthyroid patients (11.1%) and 2 out of 23 hypothyroid patients (8.7%) had ETR values within normal range and among the 56 euthyroid patients 6 (10.7%) had ETR values outside normal range, so the diagnostic compatibility of ETR was 89.4% in thyroid diseases. 4) Even though the ETR value was well correlated with 131 I-thyroid uptake rate, serum T 3 resin uptake rate and serum T 4 , a high positive correlation was found (r=0.79) between ETR and T 7 . 5) The mean ETR values from patients with alteration in TBG binding capacity were 0.99±0.05 in pregnant women, 0.98±0.04 in women with oral contraceptive medication, 1.04±0.09 in liver cirrhosis patients and 0.94±0.02 in nephrotic syndrome patients and most of them (85.2%) had ETR values within normal range. Our results, therefore, suggests that the ETR estimation does offer the simplest and most reliable single procedure for the screening and diagnosis of various thyroid diseases as a indirect indicator of serum-free thyroxine concentration without essential influence of changes in the thyroxine-binding proteins in serum.

  13. Diagnostic Evaluation of Effective Thyroxine Ratio

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Chul; Choi, Sang Jae; Ro, Heung Kyu; Lee, Hong Kyu; Koh, Chang Soon; Lee, Mun Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1975-09-15

    The purpose of the present study is to evaluate the diagnostic value of the ETR test as compared to other thyroid function tests in normal persons, patients with thyroid disorders and patients with alterations of thyroxine-binding proteins. The ETR values were obtained from 35 cases as normal control, 63 hyperthyroid patients, 56 euthyroid patients, 23 hypothyroid patients, 10 pregnant women, 5 women taking oral contraceptive medication, 8 liver cirrhosis patients and 4 nephrotic syndrome patients. The results obtained were as follows. 1) The mean value of ETR obtained from the normal controls was 0.99+-0.06. 2) The mean ETR values of various thyroid states were 1.25+-0.16 in hyperthyroidism, 0.99+-0.08 in euthyroidism and 0.82+-0.05 in hypothyroidism and significant difference was found between these groups. 3) Seven out of 63 hyperthyroid patients (11.1%) and 2 out of 23 hypothyroid patients (8.7%) had ETR values within normal range and among the 56 euthyroid patients 6 (10.7%) had ETR values outside normal range, so the diagnostic compatibility of ETR was 89.4% in thyroid diseases. 4) Even though the ETR value was well correlated with {sup 131}I-thyroid uptake rate, serum T{sub 3} resin uptake rate and serum T{sub 4}, a high positive correlation was found (r=0.79) between ETR and T{sub 7}. 5) The mean ETR values from patients with alteration in TBG binding capacity were 0.99+-0.05 in pregnant women, 0.98+-0.04 in women with oral contraceptive medication, 1.04+-0.09 in liver cirrhosis patients and 0.94+-0.02 in nephrotic syndrome patients and most of them (85.2%) had ETR values within normal range. Our results, therefore, suggests that the ETR estimation does offer the simplest and most reliable single procedure for the screening and diagnosis of various thyroid diseases as a indirect indicator of serum-free thyroxine concentration without essential influence of changes in the thyroxine-binding proteins in serum.

  14. Minimizing Load Effects on NA4 Gear Vibration Diagnostic Parameter

    Science.gov (United States)

    Dempsey, Paula J.; Zakrajsek, James J.

    2001-01-01

    NA4 is a vibration diagnostic parameter, developed by researchers at NASA Glenn Research Center, for health monitoring of gears in helicopter transmissions. The NA4 reacts to the onset of gear pitting damage and continues to react to the damage as it spreads. This research also indicates NA4 reacts similarly to load variations. The sensitivity of NA4 to load changes will substantially affect its performance on a helicopter gearbox that experiences continuously changing load throughout its flight regimes. The parameter NA4 has been used to monitor gear fatigue tests at constant load. At constant load, NA4 effectively detects the onset of pitting damage and tracks damage severity. Previous research also shows that NA4 reacts to changes in load applied to the gears in the same way it reacts to the onset of pitting damage. The method used to calculate NA4 was modified to minimize these load effects. The modified NA4 parameter was applied to four sets of experimental data. Results indicate the modified NA4 is no longer sensitive to load changes, but remains sensitive to pitting damage.

  15. Companion diagnostics

    DEFF Research Database (Denmark)

    Jørgensen, Jan Trøst; Hersom, Maria

    2016-01-01

    of disease mechanisms, things are slowly changing. Within the last few years, we have seen an increasing number of predictive biomarker assays being developed to guide the use of targeted cancer drugs. This type of assay is called companion diagnostics and is developed in parallel to the drug using the drug-diagnostic...... co-development model. The development of companion diagnostics is a relatively new discipline and in this review, different aspects will be discussed including clinical and regulatory issues. Furthermore, examples of drugs, such as the ALK and PD-1/PD-L1 inhibitors, that have been approved recently....... Despite having discussed personalized medicine for more than a decade, we still see that most drug prescriptions for severe chronic diseases are largely based on 'trial and error' and not on solid biomarker data. However, with the advance of molecular diagnostics and a subsequent increased understanding...

  16. Diagnostic information management system for the evaluation of medical images

    Energy Technology Data Exchange (ETDEWEB)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina

    1985-04-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions.

  17. Diagnostic information management system for the evaluation of medical images

    International Nuclear Information System (INIS)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina.

    1985-01-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions. (author)

  18. Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; Reitsma, Johannes B.; Linnet, Kristian; Moons, Karel G. M.

    2012-01-01

    Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical

  19. ECE diagnostics for RTO/RC ITER

    International Nuclear Information System (INIS)

    Vayakis, G.; Bartlett, D.V.; Costley, A.E.

    2001-01-01

    This paper presents the current status of the Electron Cyclotron Emission (ECE) diagnostic on the Reduced Technical Objectives/Reduced Cost International Thermonuclear Experimental Reactor (RTO/RC ITER). It discusses the implications of the new machine design on the measurement requirements, the ability of the diagnostic technique to meet these, and the changes in the implementation imposed by the new layout. Finally, it outlines the physics studies, design and R and D work required prior to the detailed design and construction of the diagnostic. Key results are: (i) that the localisation of the measurement is similar to that in ITER-FDR (40-100 mm in X-mode, 60-200 mm in O-mode for the reference scenario), so that the relative spatial resolution degrades in this, smaller, machine, and (ii) the expected effect of transport barriers on the temperature profile in the high temperature region will be poorly resolved, because the effect of the temperature gradient on the outboard side is to degrade the resolution to (∼250 mm in X-mode, ∼350 mm in O-mode). Nevertheless ECE will be able to make a unique and useful contribution to the RTO/RC ITER measurement set

  20. Patient dosimetry in diagnostic radiology

    Directory of Open Access Journals (Sweden)

    Ciraj-Bjelac Olivera F.

    2003-01-01

    Full Text Available The objective of this work is to assess patient organ doses, effective doses and entrance surface doses in conventional diagnostic radiology procedures for standard adult patient. The survey consists of measurements of doses delivered to 239 patients in nine types of X-ray examinations. Three types of data were collected: X-ray machine data, patient data, and output measurements. Entrance surface dose was assessed based on the survey data and subsequently, using conversion coefficients, the organ doses and effective doses were calculated. Values of the entrance surface dose and the effective dose were estimated to be 0.4 to 5.8 mGy and 0.03 to 3.00 mSv for different examinations. Derived doses were compared with recommended general diagnostic reference levels. The impact of examination parameters on dose values was discussed. Except for posterior-anterior chest examination, all estimated doses are lower than stated reference levels. Survey data are aimed at helping development of national quality control and radiation protection programmed for medical exposures.

  1. Decision analysis to complete diagnostic research by closing the gap between test characteristics and cost-effectiveness

    NARCIS (Netherlands)

    Schaafsma, Joanna D.; van der Graaf, Yolanda; Rinkel, Gabriel J. E.; Buskens, Erik

    2009-01-01

    Objective: The lack of a standard methodology in diagnostic research impedes adequate evaluation before implementation of constantly developing diagnostic techniques. We discuss the methodology of diagnostic research and underscore the relevance of decision analysis in the process of evaluation of

  2. Cost analysis of breast cancer diagnostic assessment programs.

    Science.gov (United States)

    Honein-AbouHaidar, G N; Hoch, J S; Dobrow, M J; Stuart-McEwan, T; McCready, D R; Gagliardi, A R

    2017-10-01

    Diagnostic assessment programs (daps) appear to improve the diagnosis of cancer, but evidence of their cost-effectiveness is lacking. Given that no earlier study used secondary financial data to estimate the cost of diagnostic tests in the province of Ontario, we explored how to use secondary financial data to retrieve the cost of key diagnostic test services in daps, and we tested the reliability of that cost-retrieving method with hospital-reported costs in preparation for future cost-effectiveness studies. We powered our sample at an alpha of 0.05, a power of 80%, and a margin of error of ±5%, and randomly selected a sample of eligible patients referred to a dap for suspected breast cancer during 1 January-31 December 2012. Confirmatory diagnostic tests received by each patient were identified in medical records. Canadian Classification of Health Intervention procedure codes were used to search the secondary financial data Web portal at the Ontario Case Costing Initiative for an estimate of the direct, indirect, and total costs of each test. The hospital-reported cost of each test received was obtained from the host-hospital's finance department. Descriptive statistics were used to calculate the cost of individual or group confirmatory diagnostic tests, and the Wilcoxon signed-rank test or the paired t-test was used to compare the Ontario Case Costing Initiative and hospital-reported costs. For the 191 identified patients with suspected breast cancer, the estimated total cost of $72,195.50 was not significantly different from the hospital-reported total cost of $72,035.52 ( p = 0.24). Costs differed significantly when multiple tests to confirm the diagnosis were completed during one patient visit and when confirmatory tests reported in hospital data and in medical records were discrepant. The additional estimated cost for non-salaried physicians delivering diagnostic services was $28,387.50. It was feasible to use secondary financial data to retrieve the cost

  3. [CONTEMPORARY MOLECULAR-GENETIC METHODS USED FOR ETIOLOGIC DIAGNOSTICS OF SEPSIS].

    Science.gov (United States)

    Gavrilov, S N; Skachkova, T S; Shipulina, O Yu; Savochkina, Yu A; Shipulin, G A; Maleev, V V

    2016-01-01

    Etiologic diagnostics of sepsis is one of the most difficult problems of contemporary medicine due to a wide variety of sepsis causative agents, many of which are components of normal human microflora. Disadvantages of contemporary "golden standard" of microbiologic diagnostics of sepsis etiology by seeding of blood for sterility are duration of cultivation, limitation in detection of non-cultivable forms of microorganisms, significant effect of preliminary empiric antibiotics therapy on results of the analysis. Methods of molecular diagnostics that are being actively developed and integrated during the last decade are deprived of these disadvantages. Main contemporary methods of molecular-biological diagnostics are examined in the review, actualdata on their diagnostic characteristic are provided. Special attention is given to methods of PCR-diagnostics, including novel Russian developments. Methods of nucleic acid hybridization and proteomic analysis are examined in comparative aspect. Evaluation of application and perspectives of development of methods of molecular diagnostics of sepsis is given.

  4. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  5. Image enhancement of digital periapical radiographs according to diagnostic tasks

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung

    2014-01-01

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  6. Image enhancement of digital periapical radiographs according to diagnostic tasks

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung [Dept. of Oral and Maxillofacial Radiology, Dankook University College of Dentistry, Cheonan (Korea, Republic of)

    2014-03-15

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  7. The possibilities of laser scattering diagnostics in plasmas

    International Nuclear Information System (INIS)

    Doebele, H.F.

    1974-01-01

    The laser has opened many new possibilities for plasma diagnostics. Intensive monochromatic light sources with higher precision and better time resolution have helped to improve such well-known techniques as interferometry and Schlieren method. At the same time, the range of applicability was extended into the infrared range. Due to the wave length dependence of the plasma diffraction index, the effects increase approximately lambda in interferometry and approximately lambda 2 in the Schlieren methods. The laser also helped to develop entirely new methods such as utilization of the Faraday effect in the electrons of a plasma in a magnetic field which allows the calculation of the product nsub(e) x B from the rotation of the polarization plane of monochromatic light with linear polarization. Here, too, the effect increases approximately lambda 2 , and measurements have been carried out up to FIR (HCN,337 μ). The best diagnostic possibilities are offered by the Thomson scattering diagnostics. Electron and ion temperatures, electron densities, drift velocities, magnetic fields, wave propagation and dissipation can be measured by this method. (orig./AK) [de

  8. A qualitative model construction method of nuclear power plants for effective diagnostic knowledge generation

    International Nuclear Information System (INIS)

    Yoshikawa, Shinji; Endou, Akira; Kitamura, Yoshinobu; Sasajima, Munehiko; Ikeda, Mitsuru; Mizoguchi, Riichiro.

    1994-01-01

    This paper discusses a method to construct a qualitative model of a nuclear power plant, in order to generate effective diagnostic knowledge. The proposed method is to prepare deep knowledge to be provided to a knowledge compiler based upon qualitative reasoning (QR). Necessity of knowledge compilation for nuclear plant diagnosis will be explained first, and conventionally-experienced problems in qualitative reasoning and a proposed method to overcome this problem is shown next, then a sample procedure to build a qualitative nuclear plant model is demonstrated. (author)

  9. Radiation hardening of diagnostics

    International Nuclear Information System (INIS)

    Siemon, R.E.

    1991-01-01

    The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique facility to help in this regard is the Los Alamos Spallation Radiation Effects Facility, a neutron source located at the beam stop of the world's most powerful accelerator, the Los Alamos Meson Physics Facility (LAMPF). The LAMPF proton beam generates 10 16 neutrons per second because of ''spallation'' reactions when the protons collide with the copper nuclei in the beam stop

  10. The Influence of Time Pressure and Case Complexity on Physicians׳ Diagnostic Performance

    Directory of Open Access Journals (Sweden)

    Dalal A. ALQahtani

    2016-12-01

    Conclusions: Time pressure did not impact the diagnostic performance, whereas the complexity of the clinical case negatively influenced the diagnostic accuracy. Further studies with the enhanced experimental manipulation of time pressure are needed to reveal the effect of time pressure, if any, on a physician׳s diagnostic performance.

  11. Effect of in utero exposure to diagnostic doses of X-rays on the growth and behaviour of mouse

    International Nuclear Information System (INIS)

    Prakash Hande, M.; Uma Devi, P.

    1992-01-01

    Intrauterine development, particularly the period of organogenesis is an especially radiosensitive phase in mammals. Teratogenic effect of low dose irradiation has been demonstrated in laboratory animals. Several studies have indicated the vulnerability of the developing human brain to radiation injury and demonstrated changes in postnatal behaviour following intrauterine animal irradiation. However, data are lacking on the comparative response of the different stages of prenatal development to low doses at levels that could result from diagnostic radiation exposure. This study attempts to empirically evaluate the differential response of critical stages in prenatal development of mouse to single low dose exposures to diagnostic X-rays. Data on growth and behaviour are briefly presented. (author). 22 refs., 2 figs., 1 tab

  12. Diagnostic errors in pediatric radiology

    International Nuclear Information System (INIS)

    Taylor, George A.; Voss, Stephan D.; Melvin, Patrice R.; Graham, Dionne A.

    2011-01-01

    Little information is known about the frequency, types and causes of diagnostic errors in imaging children. Our goals were to describe the patterns and potential etiologies of diagnostic error in our subspecialty. We reviewed 265 cases with clinically significant diagnostic errors identified during a 10-year period. Errors were defined as a diagnosis that was delayed, wrong or missed; they were classified as perceptual, cognitive, system-related or unavoidable; and they were evaluated by imaging modality and level of training of the physician involved. We identified 484 specific errors in the 265 cases reviewed (mean:1.8 errors/case). Most discrepancies involved staff (45.5%). Two hundred fifty-eight individual cognitive errors were identified in 151 cases (mean = 1.7 errors/case). Of these, 83 cases (55%) had additional perceptual or system-related errors. One hundred sixty-five perceptual errors were identified in 165 cases. Of these, 68 cases (41%) also had cognitive or system-related errors. Fifty-four system-related errors were identified in 46 cases (mean = 1.2 errors/case) of which all were multi-factorial. Seven cases were unavoidable. Our study defines a taxonomy of diagnostic errors in a large academic pediatric radiology practice and suggests that most are multi-factorial in etiology. Further study is needed to define effective strategies for improvement. (orig.)

  13. Diagnostic interface problems on TFTR

    International Nuclear Information System (INIS)

    Goldfarb, S.

    1977-01-01

    Diagnostic equipment on TFTR has functional interfaces with many machine systems. Salient requirements include plasma access, environmental resistance to thermal, magnetic and radiation effects, automated data acquisition and controls, remote handling and personnel safety. Problems imposed by these requirements and the solutions being considered are described

  14. Radiation exposure in diagnostic medicine

    International Nuclear Information System (INIS)

    Haehnel, S.; Michalczak, H.; Reinoehl-Kompa, S.

    1995-01-01

    This volume includes the manuscripts of the papers read at the conference as well as a summary and assessment of its results. The scientific discussions were centred upon the following issues: - International surveys and comparisons of rdiation exposures in diagnostic radiology and nuclear medicine, frequency of the individual diagnostic procedures and age distribution of patients examined; - policies and regulations for the radiation protection of patients, charcteristic dosimetric values and practical usefulness of the effective dose concept during medical examinations; - assessments of the relative benefits and risks and measures to reduce the radiation exposure in the light of quality assurance aspects. The main objective of this conference not only was to evaluate the risks from diagnostic radiology and nuclear medicine but also to encourgage a critical analysis and adjustment of examination routines followed in everyday practice. Among the measures recommended were quality assurance, maintenace of international standards, development of guidelines, introduction of standard doses, improved training and professional education of personnel as well as surveys and analyses of certain examination procedures associated with substantial radiation exposure. (orig./MG) [de

  15. 42 CFR 415.180 - Teaching setting requirements for the interpretation of diagnostic radiology and other diagnostic...

    Science.gov (United States)

    2010-10-01

    ... interpretation of diagnostic radiology and other diagnostic tests. 415.180 Section 415.180 Public Health CENTERS... for the interpretation of diagnostic radiology and other diagnostic tests. (a) General rule. Physician fee schedule payment is made for the interpretation of diagnostic radiology and other diagnostic tests...

  16. Developing Pairwise Preference-Based Personality Test and Experimental Investigation of Its Resistance to Faking Effect by Item Response Model

    Science.gov (United States)

    Usami, Satoshi; Sakamoto, Asami; Naito, Jun; Abe, Yu

    2016-01-01

    Recent years have shown increased awareness of the importance of personality tests in educational, clinical, and occupational settings, and developing faking-resistant personality tests is a very pragmatic issue for achieving more precise measurement. Inspired by Stark (2002) and Stark, Chernyshenko, and Drasgow (2005), we develop a pairwise…

  17. Diagnostic system for primary circuits of pressurized-water reactors

    International Nuclear Information System (INIS)

    Liska, J.; Majer, J.

    1983-01-01

    The diagnostic system monitors the reactor, the main circulating pipe, the main circulating pump, the main shut-off valve, the steam generator and the pressurizer. Diagnostic signals are obtained from the sensors designed for operation measurements and from sensors for special diagnostic purposes. The following operations are carried out: detection of dangerous dynamic stress of components, detection of damage to functional surfaces of components, detection of occurrence and propagation of defects in component materials, detection of loose particles and foreign bodies, detection of coolant leakage, detection of coolant boiling in the core and detection of impermissible non-homogeneities of fields of physical quantities in the core. The diagnostic system comprises: monitoring, classification of properly investigated effects, periodical tracing and long-term tracing. The operational diagnostics system developed by the SKODA Concern consists of a vibration monitoring system, a spectral analysis system and a central evaluation system. (M.D.)

  18. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  19. Synergy Effect of Combining Fluorescence and Mid Infrared Fiber Spectroscopy for Kidney Tumor Diagnostics

    Directory of Open Access Journals (Sweden)

    Andrey Bogomolov

    2017-11-01

    Full Text Available Matching pairs of tumor and non-tumor kidney tissue samples of four patients were investigated ex vivo using a combination of two methods, attenuated total reflection mid infrared spectroscopy and fluorescence spectroscopy, through respectively prepared and adjusted fiber probes. In order to increase the data information content, the measurements on tissue samples in both methods were performed in the same 31 preselected positions. Multivariate data analysis revealed a synergic effect of combining the two methods for the diagnostics of kidney tumor compared to individual techniques.

  20. Diagnostic dilemma

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Dobrovolny, Robert; Nazarenko, Irina

    2011-01-01

    Fabry disease, an X-linked lysosomal storage disorder, results from the deficient activity of a-galactosidase A (a-Gal A). In affected males, the clinical diagnosis is confirmed by the markedly decreased a-Gal A activity. However, in female heterozygotes, the a-Gal A activity can range from low t...... on enzyme replacement therapy. Thus, gene dosage analyses can detect large deletions (>50bp) in suspect heterozygotes for X-linked and autosomal dominant diseases that are "sequencing cryptic," resolving molecular diagnostic dilemmas....... to normal due to random X-chromosomal inactivation, and diagnostic confirmation requires identification of the family's a-Gal A gene mutation. In a young female who had occasional acroparesthesias, corneal opacities, and 15 to 50% of the lower limit of normal leukocyte a-Gal A activity, a-Gal A sequencing...... in two expert laboratories did not identify a confirmatory mutation, presenting a diagnostic dilemma. A renal biopsy proved diagnostic and renewed efforts to detect an a-Gal A mutation. Subsequent gene dosage analyses identified a large a-Gal A deletion confirming her heterozygosity, and she was started...

  1. Modeling of novel diagnostic strategies for active tuberculosis - a systematic review: current practices and recommendations.

    Directory of Open Access Journals (Sweden)

    Alice Zwerling

    Full Text Available The field of diagnostics for active tuberculosis (TB is rapidly developing. TB diagnostic modeling can help to inform policy makers and support complicated decisions on diagnostic strategy, with important budgetary implications. Demand for TB diagnostic modeling is likely to increase, and an evaluation of current practice is important. We aimed to systematically review all studies employing mathematical modeling to evaluate cost-effectiveness or epidemiological impact of novel diagnostic strategies for active TB.Pubmed, personal libraries and reference lists were searched to identify eligible papers. We extracted data on a wide variety of model structure, parameter choices, sensitivity analyses and study conclusions, which were discussed during a meeting of content experts.From 5619 records a total of 36 papers were included in the analysis. Sixteen papers included population impact/transmission modeling, 5 were health systems models, and 24 included estimates of cost-effectiveness. Transmission and health systems models included specific structure to explore the importance of the diagnostic pathway (n = 4, key determinants of diagnostic delay (n = 5, operational context (n = 5, and the pre-diagnostic infectious period (n = 1. The majority of models implemented sensitivity analysis, although only 18 studies described multi-way sensitivity analysis of more than 2 parameters simultaneously. Among the models used to make cost-effectiveness estimates, most frequent diagnostic assays studied included Xpert MTB/RIF (n = 7, and alternative nucleic acid amplification tests (NAATs (n = 4. Most (n = 16 of the cost-effectiveness models compared new assays to an existing baseline and generated an incremental cost-effectiveness ratio (ICER.Although models have addressed a small number of important issues, many decisions regarding implementation of TB diagnostics are being made without the full benefits of insight from mathematical

  2. Implementation of Rapid Molecular Infectious Disease Diagnostics: the Role of Diagnostic and Antimicrobial Stewardship.

    Science.gov (United States)

    Messacar, Kevin; Parker, Sarah K; Todd, James K; Dominguez, Samuel R

    2017-03-01

    New rapid molecular diagnostic technologies for infectious diseases enable expedited accurate microbiological diagnoses. However, diagnostic stewardship and antimicrobial stewardship are necessary to ensure that these technologies conserve, rather than consume, additional health care resources and optimally affect patient care. Diagnostic stewardship is needed to implement appropriate tests for the clinical setting and to direct testing toward appropriate patients. Antimicrobial stewardship is needed to ensure prompt appropriate clinical action to translate faster diagnostic test results in the laboratory into improved outcomes at the bedside. This minireview outlines the roles of diagnostic stewardship and antimicrobial stewardship in the implementation of rapid molecular infectious disease diagnostics. Copyright © 2017 American Society for Microbiology.

  3. Development of global data warehouse for beam diagnostics at SSRF

    International Nuclear Information System (INIS)

    Lai Longwei; Leng Yongbin; Yan Yingbing; Chen Zhichu

    2015-01-01

    The beam diagnostic system is adequate during the daily operation and machine study at the Shanghai Synchrotron Radiation Facility (SSRF). Without the effective event detecting mechanism, it is difficult to dump and analyze abnormal phenomena such as the global orbital disturbance, the malfunction of the BPM and the noise of the DCCT. The global beam diagnostic data warehouse was built in order to monitor the status of the accelerator and the beam instruments. The data warehouse was designed as a Soft IOC hosted on an independent server. Once abnormal phenomena happen it will be triggered and will store the relevant data for further analysis. The results show that the data warehouse can detect abnormal phenomena of the machine and the beam diagnostic system effectively, and can be used for calculating confidential indicators of the beam instruments. It provides an efficient tool for the improvement of the beam diagnostic system and accelerator. (authors)

  4. Childhood Enuresis: Current Diagnostic Formulations, Salient Findings, and Effective Treatment Modalities.

    Science.gov (United States)

    Thurber, Steven

    2017-06-01

    Enuresis constitutes a frequently encountered problem area for children that may adversely affect social and emotional adjustment. This type of incontinence has been of concern to the human family for centuries. A brief history of enuresis is presented followed by current conceptualizations, diagnostic criteria, prevalence rates and psychiatric comorbidities. Historic notions of causation together with ineffective, sometimes barbaric treatments are then discussed, ending with a presentation of evidence-based treatment modalities, with the urine alarm being an essential element of effective treatment. An intervention termed dry bed training combines the urine alarm with a series of procedures designed in part to reduce relapse potential and should be a primary consideration for implementation by treatment professionals. Finally, a brief case study is presented illustrating special etiological and treatment considerations with juvenile psychiatric patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Effect of Bovine Serum Albumin Treatment on the Aging and Activity of Antibodies in Paper Diagnostics

    Science.gov (United States)

    Huang, Ziwei; Gengenbach, Thomas; Tian, Junfei; Shen, Wei; Garnier, Gil

    2018-05-01

    Paper and cellulosic films are used in many designs of low-cost diagnostics such as paper-based blood grouping devices. A major issue limiting their commercialization is the short stability of the functional biomolecules. To address this problem, the effect of relative humidity (RH) and bovine serum albumin (BSA) on the antibody bioactivity and the surface chemical composition of a paper blood typing biodiagnostic were studied. An IgM blood typing antibody was physisorbed from solution onto paper - with or without BSA pretreatment, and aged for periods up to 9 weeks at room temperature and under different RH conditions. The blood typing efficiency of the antibodies and the substrate surface chemical composition were analyzed by image analysis and X-ray photoelectron spectroscopy (XPS), respectively. This study tests two hypotheses. The first is that the hydroxyl groups in paper promote antibody denaturation on paper; the second hypothesis is that proteins such as BSA can partially block the hydroxyl groups with paper, thus preserving antibody bioactivity. Results show that high RH is detrimental to antibody longevity on paper, while BSA can block hydroxyl groups and prolong antibody longevity by almost an order of magnitude – regardless of humidity. This study opens up new engineering concepts to develop robust and marketable paper diagnostics. The simplest is to store paper and antibody based diagnostics in moisture proof packages.

  6. Recall Tests Are Effective to Detect Mild Cognitive Impairment: A Systematic Review and Meta-analysis of 108 Diagnostic Studies.

    Science.gov (United States)

    Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S

    2017-09-01

    Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most

  7. Chapter 7: Diagnostics [Progress in the ITER Physics Basis (PIPB)

    International Nuclear Information System (INIS)

    Donne, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    diagnostics to measure a selected set of plasma parameters is presented. The integration of the various diagnostic systems onto the ITER tokamak is described. Generic research and development in the field of irradiation effects on materials and environmental effects on first mirrors are briefly presented. The paper ends with an assessment of the measurement capability for ITER and a forward of what will be gained from operation of the various diagnostic systems on ITER in preparation for the machines that will follow ITER

  8. Effects on costs of frontline diagnostic evaluation in patients suspected of angina: coronary computed tomography angiography vs. conventional ischaemia testing

    DEFF Research Database (Denmark)

    Nielsen, Lene H; Olsen, Jens; Markenvard, John

    2013-01-01

    group. The mean (SD) total costs per patient at the end of thefollow-up were 14% lower in the CTA group than in the ex-test group, € 1510 (3474) vs. €1777 (3746) (P = 0.03). CONCLUSION: Diagnostic assessment of symptomatic patients with a low-intermediate probability of CAD by CTA incurred lower costs......AIMS: The aim of this study was to investigate in patients with stable angina the effects on costs of frontline diagnostics by exercise-stress testing (ex-test) vs. coronary computed tomography angiography (CTA). METHODS AND RESULTS: In two coronary units at Lillebaelt Hospital, Denmark, 498...... patients were identified in whom either ex-test (n = 247) or CTA (n = 251) were applied as the frontline diagnostic strategy in symptomatic patients with a low-intermediate pre-test probability of coronary artery disease (CAD). During 12 months of follow-up, death, myocardial infarction and costs...

  9. Contrast-enhanced three-dimensional MR angiography of neck vessels: does dephasing effect alter diagnostic accuracy?

    International Nuclear Information System (INIS)

    Cosottini, M.; Calabrese, R.; Murri, L.; Puglioli, M.; Zampa, V.; Michelassi, M.C.; Ortori, S.; Bartolozzi, C.

    2003-01-01

    The aim of this study was to evaluate diagnostic accuracy of contrast-enhanced MRA (CEMRA) compared with digital subtraction angiography (DSA) in studying neck vessels of 48 patients. In three groups of patients, we used three MRA protocols differing for voxel size to assess if intravoxel dephasing effects could modify accuracy of CEMRA. Accuracy and correlation with DSA results were calculated in all patients and separately in the three groups. A qualitative analysis of the likeness between morphology of the stenosis in CEMRA and DSA images was also assessed. In all patients accuracy and agreement with DSA were 96% and k=0.85 in subclavian arteries, 96% and k=0.84 in vertebral artery, 97% and k=0.88 in common carotid arteries, and 94% and k=0.86 in internal carotid arteries. In the three groups accuracy and agreement with DSA did not show any significant difference. Qualitative analysis of CEMRA and DSA images revealed a better agreement in depicting the morphology of stenosis using a smaller voxel size. The CEMRA represents a powerful tool for the non-invasive evaluation of neck vessels. Overestimation trend of CEMRA is confirmed and the reduction of voxel size, decreasing the dephasing intravoxel effect, allows to have a better overlapping of stenosis morphology on CEMRA compared with DSA, but it does not yield diagnostic gain in the stenosis grading. (orig.)

  10. Challenges of ITER diagnostic electrical services

    Energy Technology Data Exchange (ETDEWEB)

    Encheva, A., E-mail: anna.encheva@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Omran, H. [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); Pérez-Lasala, M. [The European Joint Undertaking for ITER and the Development of Fusion Energy, c/Josep Pla, n° 2, Torres Diagonal Litoral, Edificio B3, 08019 Barcelona (Spain); Alekseev, A. [Efremov Institute, Metallostroy, Doroga na Metallostroy, 3 bld., Saint-Petersburg 196641 (Russian Federation); Arshad, S. [The European Joint Undertaking for ITER and the Development of Fusion Energy, c/Josep Pla, n° 2, Torres Diagonal Litoral, Edificio B3, 08019 Barcelona (Spain); Bede, O. [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); Bender, S. [Efremov Institute, Metallostroy, Doroga na Metallostroy, 3 bld., Saint-Petersburg 196641 (Russian Federation); Bertalot, L.; Direz, M.-F.; Drevon, J.-M.; Jakhar, S.; Kaschuk, Y.; Komarov, V.; Lebarbier, R. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Lucca, F. [L.T. Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Macklin, B.; Maquet, P. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Marin, A. [L.T. Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Martin, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Mills, S. [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); and others

    2013-10-15

    Highlights: • A brief description of all major components part of diagnostic electrical services has been given. • The integration challenges have been presented. • Design assumptions and requirements for the components have been described. • The design of the conduit/loom and the relevant analysis has been highlighted. -- Abstract: Diagnostic electrical services provide the electrical infrastructure to serve diagnostic components installed on the ITER tokamak. This infrastructure is composed of cables, connectors, cable tails, looms, conduits and feedthroughs. The diagnostic services offer as well a shelter for various instrumentations – vacuum vessel (VV), blanket and divertor. The diagnostic sensors are located on the inner and outer VV wall, on blanket shield modules, divertor cassettes and in port plugs. They require electrical cabling to extract the measurement and, in some cases, to supply electrical power to the sensors. These cables run from the sensors to feedthroughs on the VV and the port interspace or cryostat. The design and integration of all components that are part of diagnostic electrical services is an important engineering activity that is being challenged by the multiple requirements and constraints which have to be satisfied while at the same time delivering the required diagnostic performance. The positioning of the components must correlate not only with their functional specifications but also with the design of the major ITER components. This is a particular challenge because not all systems have reached the same level of design maturity. This paper outlines the engineering challenges of ITER diagnostics electrical services. The environmental conditions inside the VV will have an important impact. Leading risks to these components include poor electrical contact at connectors, the effects of exposure to nuclear irradiation, such as material transmutation, heating, and generation of spurious electrical signals etc., failure due to

  11. Cerebrovascular effects of intraarterial CO2 in quantities required for diagnostic imaging

    International Nuclear Information System (INIS)

    Coffey, R.; Quisling, R.G.; Mickle, J.P.; Hawkins, I.F. Jr.; Ballinger, W.B.

    1984-01-01

    The recent development of digital subtraction angiography (DSA) has renewed interest in the use of gasses, especially carbon dioxide, as contrast agents. Both early physiologic studies and recent clinical reports suggest that arterial CO 2 -DSA is a safe and useful diagnostic tool in the examination of extremity circulation. The present study examined the neurologic sequelae, pathologic changes, and effects on the blood-brain barrier to intravenous Evans-Blue and horseradish peroxidase of intracarotid CO 2 , in albino rats. As with other forms of cerebral gas embolization, CO 2 produced multifocal ischemic infarctions and disrupted the blood-brain barrier to macromolecular tracers. The site of the barrier lesion is the endothelial cell membrane, although the precise mechanisms of damage remain unknown

  12. Diagnostics Upgrades for Investigations of HOM Effects in TESLA-type SCRF Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Edstrom Jr., D.; Ruan, J. [Fermilab; Thurman-Keup, R. [Fermilab; Shin, Y. [Fermilab; Prieto, P. [Fermilab; Eddy, N. [Fermilab; Carlsten, B. E. [Los Alamos

    2017-08-23

    We describe the upgrades to diagnostic capabilities on the Fermilab Accelerator Science and Technology (FAST) electron linear accelerator that will allow investigations of the effects of high-order modes (HOMs) in SCRF cavities on macropulse-average beam quality. We examine the dipole modes in the first pass-band generally observed in the 1.6-1.9 GHz regime for TESLA-type SCRF cavities due to uniform transverse beam offsets of the electron beam. Such cavities are the basis of the accelerators such as the European XFEL and the proposed MaRIE XFEL facility. Preliminary HOM detector data, prototype BPM test data, and first framing camera OTR data with ~20- micron spatial resolution at 250 pC per bunch will be presented.

  13. Diagnostic Algorithm Benchmarking

    Science.gov (United States)

    Poll, Scott

    2011-01-01

    A poster for the NASA Aviation Safety Program Annual Technical Meeting. It describes empirical benchmarking on diagnostic algorithms using data from the ADAPT Electrical Power System testbed and a diagnostic software framework.

  14. Biological mechanisms of radiation effects; Biologische Mechanismen der Strahlenwirkung

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, S.; Doerr, W. [Medizinische Universitaet Wien, ATRAB - Angewandte und Translationale Radiobiologie, Univ.-Klinik fuer Strahlentherapie, Wien (Austria)

    2017-07-15

    Exposure to ionizing radiation for diagnostic purposes is inevitable in modern medicine. The therapeutic application of irradiation is highly effective against cancer; however, this implies exposure of normal tissue structures to significant doses of radiation. Diagnostic or therapeutic exposure to ionizing radiation can result in tissue changes and tumor induction in the long term. Knowledge of the biological mechanisms underlying these effects is essential for individualization of the application. This article examines the biological mechanisms at the tissue and molecular level, the clinical manifestation of radiation effects, dose-dependence of the risk and the temporal progression as well as influencing factors. The time course of the reaction of tissues to radiation exposure extends over wide ranges up to many decades. The effects of radiation on tissues are classified into early and late and their pathobiology is significantly different. Various factors (R) influencing the clinical manifestation of radiation effects have been identified related to the exposure pattern. The radiation tolerance of normal tissue structures regarding the induction of functional deficits shows great variation but always has a threshold value, which is usually not exceeded in diagnostic procedures. The risk of a radiation-induced fatal malignancy (total body exposure 5%/Gy) for a medical administration of radiation must be considered as very low in comparison to the natural risks. Informed consent of patients must reflect this in a balanced way. (orig.) [German] Eine Exposition mit ionisierender Strahlung fuer diagnostische Zwecke ist in der modernen Medizin unumgaenglich. Bei einer Tumorerkrankung ist die therapeutische Anwendung dieser Strahlung hoch effektiv. Dies impliziert immer eine Exposition normaler Gewebestrukturen mit signifikanten Strahlendosen. Die diagnostische oder therapeutische Exposition mit ionisierender Strahlung kann langfristig zu Gewebeveraenderungen und

  15. Economic evaluation of diagnostic localization following biochemical prostate cancer recurrence.

    Science.gov (United States)

    Barocas, Daniel A; Bensink, Mark E; Berry, Kristin; Musa, Zahra; Bodnar, Carolyn; Dann, Robert; Ramsey, Scott D

    2014-10-01

    The aim of this study was to assess potential cost-effectiveness of using a prostate cancer specific functional imaging technology capable of identifying residual localized disease versus small volume metastatic disease for asymptomatic men with low but detectable prostate specific antigen (PSA) elevation following radical prostatectomy. Markov modeling was used to estimate the incremental impact on healthcare system costs (2012 USD) and quality-adjusted life-years (QALYs) of two alternative strategies: (i) using the new diagnostic to guide therapy versus (ii) current usual care-using a combination of computed tomography, magnetic resonance imaging, and bone scan to guide therapy. Costs were based on estimates from literature and Medicare reimbursement. Prostate cancer progression, survival, utilities, and background risk of all-cause mortality were obtained from literature. Base-case diagnostic sensitivity (75 percent), specificity (90 percent), and cost (USD 2,500) were provided by our industry partner GE Healthcare. The new diagnostic strategy provided an average gain of 1.83 (95 percent uncertainty interval [UI]: 1.24-2.64) QALYs with added costs of USD 15,595 (95 percent UI: USD -6,330-44,402) over 35 years. The resulting incremental cost-effectiveness ratio was USD 8,516/QALY (95 percent UI: USD -2,947-22,372). RESULTS were most influenced by the utility discounting rate and test performance characteristics; however, the new diagnostic provided clinical benefits over a wide range of sensitivity and specificity. This analysis suggests a diagnostic technology capable of identifying whether men with biochemical recurrence after radical prostatectomy have localized versus metastatic disease would be a cost-effective alternative to current standard work-up. The results support additional investment in development and validation of such a diagnostic.

  16. Dentistry 4. X-ray diagnostics

    International Nuclear Information System (INIS)

    2014-01-01

    DIN pocketbook 267/4 gives an overview of the normative requirements of the new X-Ray and Radiation Protection Ordinance, which has been in effect since 1 November 2011. This DIN pocketbook is intended for anyone charged with professional responsibility for the use of ionizing radiation in dentistry, operators and users of x-ray devices, radiation protection officers, accredited experts, manufacturers as well as for anyone with an interest in radiation protection or optimal radiological diagnostics. It contains standards relating to the following areas: acceptance and constancy testing; devices for evaluating findings (monitors, film viewing devices), films, printers; archiving, designating, labelling. Adherence to the standards makes it possible to avoid distractive artefacts in x-ray images and optimise the quality of x-ray diagnostics in dentistry.

  17. Cognitive diagnostic assessment via Bayesian evaluation of informative diagnostic hypotheses.

    NARCIS (Netherlands)

    Hoijtink, Herbert; Béland, Sébastien; Vermeulen, Jorine A.

    2014-01-01

    There exist diverse approaches that can be used for cognitive diagnostic assessment, such as mastery testing, constrained latent class analysis, rule space methodology, diagnostic cognitive modeling, and person-fit analysis. Each of these approaches can be used within 1 of the 4 psychometric

  18. Cognitive Diagnostic Assessment via Bayesian Evaluation of Informative Diagnostic Hypotheses

    NARCIS (Netherlands)

    Hoitink, Herbert; Beland, Sebastien; Vermeulen, Jorine

    2014-01-01

    There exist diverse approaches that can be used for cognitive diagnostic assessment, such as mastery testing, constrained latent class analysis, rule space methodology, diagnostic cognitive modeling, and person-fit analysis. Each of these approaches can be used within 1 of the 4 psychometric

  19. Guide to good practices for teamwork training and diagnostic skills development

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This guide provides assistance in the development, implementation, and improvement of training on teamwork and diagnostics. DOE and contractor representatives identified the need for teamwork and diagnostics training guidance. This need was based on the increasing emphasis of properly applying knowledge and skills to complete assigned tasks. Teamwork and diagnostic skills have become a focal point because of the impact they have on effective facility operation and safety.

  20. Molecular Diagnostics

    OpenAIRE

    Choe, Hyonmin; Deirmengian, Carl A.; Hickok, Noreen J.; Morrison, Tiffany N.; Tuan, Rocky S.

    2015-01-01

    Orthopaedic infections are complex conditions that require immediate diagnosis and accurate identification of the causative organisms to facilitate appropriate management. Conventional methodologies for diagnosis of these infections sometimes lack accuracy or sufficient rapidity. Current molecular diagnostics are an emerging area of bench-to-bedside research in orthopaedic infections. Examples of promising molecular diagnostics include measurement of a specific biomarker in the synovial fluid...

  1. The Effects of Signal Erosion and Core Genome Reduction on the Identification of Diagnostic Markers

    Directory of Open Access Journals (Sweden)

    Jason W. Sahl

    2016-09-01

    Full Text Available Whole-genome sequence (WGS data are commonly used to design diagnostic targets for the identification of bacterial pathogens. To do this effectively, genomics databases must be comprehensive to identify the strict core genome that is specific to the target pathogen. As additional genomes are analyzed, the core genome size is reduced and there is erosion of the target-specific regions due to commonality with related species, potentially resulting in the identification of false positives and/or false negatives.

  2. Evaluation of the Revised Algorithm of Autism Diagnostic Observation Schedule (ADOS) in the Diagnostic Investigation of High-Functioning Children and Adolescents with Autism Spectrum Disorders

    Science.gov (United States)

    Kamp-Becker, Inge; Ghahreman, Mardjan; Heinzel-Gutenbrunner, Monika; Peters, Mira; Remschmidt, Helmut; Becker, Katja

    2013-01-01

    The Autism Diagnostic Observation Schedule (ADOS) is a semi-structured, standardized assessment designed for use in diagnostic evaluation of individuals with suspected autism spectrum disorder (ASD). The ADOS has been effective in categorizing children who definitely have autism or not, but has lower specificity and sometimes sensitivity for…

  3. Diagnostics, therapy and ecology of thyroid diseases

    International Nuclear Information System (INIS)

    Stieve, F.E.; Roedler, H.D.

    1983-01-01

    Topical problems concerning diagnostics, therapy and ecology of thyroid diseases were discussed on an international level at this symposium. As the problems are mostly medical in nature, the symposium started with papers on the anatomy, physiology, and pathology of the thyroid, followed by lectures on dose calculation and dose/effect relationships. Particular attention is paid to the distinction between external radiation exposure and incorporation of radioactive materials, especially iodine. Another section of the symposium was dedicated to the establishment of radiation hazards. The symposium ended with a discussion of the value of diagnostic and therapeutical procedures. The extensive discussions between experts from different nations and different fields of science have surely helped to deepen the knowledge on radiation effects. (orig./MG) [de

  4. Prioritizing comparative effectiveness research for cancer diagnostics using a regional stakeholder approach.

    Science.gov (United States)

    Klein, Gregory; Gold, Laura S; Sullivan, Sean D; Buist, Diana S M; Ramsey, Scott; Kreizenbeck, Karma; Snell, Kyle; Loggers, Elizabeth Trice; Gifford, Joseph; Watkins, John B; Kessler, Larry

    2012-05-01

    This paper describes our process to engage regional stakeholders for prioritizing comparative effectiveness research (CER) in cancer diagnostics. We also describe a novel methodology for incorporating stakeholder data and input to inform the objectives of selected CER studies. As an integrated component to establishing the infrastructure for community-based CER on diagnostic technologies, we have assembled a regional stakeholder group composed of local payers, clinicians and state healthcare representatives to not only identify and prioritize CER topics most important to the western Washington State region, but also to inform the study design of selected research areas. A landscape analysis process combining literature searches, expert consultations and stakeholder discussions was used to identify possible CER topics in cancer diagnostics. Stakeholders prioritized the top topics using a modified Delphi/group-nominal method and a standardized evaluation criteria framework to determine a final selected CER study area. Implementation of the selected study was immediate due to a unique American Recovery and Reinvestment Act funding structure involving the same researchers and stakeholders in both the prioritization and execution phases of the project. Stakeholder engagement was enhanced after study selection via a rapid analysis of a subset of payers' internal claims, coordinated by the research team, to obtain summary data of imaging patterns of use. Results of this preliminary analysis, which we termed an 'internal analysis,' were used to determine with the stakeholders the most important and feasible study objectives. Stakeholders identified PET and MRI in cancers including breast, lung, lymphoma and colorectal as top priorities. In an internal analysis of breast cancer imaging, summary data from three payers demonstrated utilization rates of advanced imaging increased between 2002 and 2009 in the study population, with a great deal of variability in use between

  5. Prioritizing comparative effectiveness research for cancer diagnostics using a regional stakeholder approach

    Science.gov (United States)

    Klein, Gregory; Gold, Laura S; Sullivan, Sean D; Buist, Diana SM; Ramsey, Scott; Kreizenbeck, Karma; Snell, Kyle; Loggers, Elizabeth Trice; Gifford, Joseph; Watkins, John B; Kessler, Larry

    2012-01-01

    Aims This paper describes our process to engage regional stakeholders for prioritizing comparative effectiveness research (CER) in cancer diagnostics. We also describe a novel methodology for incorporating stakeholder data and input to inform the objectives of selected CER studies. Materials & methods As an integrated component to establishing the infrastructure for community-based CER on diagnostic technologies, we have assembled a regional stakeholder group composed of local payers, clinicians and state healthcare representatives to not only identify and prioritize CER topics most important to the western Washington State region, but also to inform the study design of selected research areas. A landscape analysis process combining literature searches, expert consultations and stakeholder discussions was used to identify possible CER topics in cancer diagnostics. Stakeholders prioritized the top topics using a modified Delphi/group-nominal method and a standardized evaluation criteria framework to determine a final selected CER study area. Implementation of the selected study was immediate due to a unique American Recovery and Reinvestment Act funding structure involving the same researchers and stakeholders in both the prioritization and execution phases of the project. Stakeholder engagement was enhanced after study selection via a rapid analysis of a subset of payers’ internal claims, coordinated by the research team, to obtain summary data of imaging patterns of use. Results of this preliminary analysis, which we termed an ‘internal analysis,’ were used to determine with the stakeholders the most important and feasible study objectives. Results Stakeholders identified PET and MRI in cancers including breast, lung, lymphoma and colorectal as top priorities. In an internal analysis of breast cancer imaging, summary data from three payers demonstrated utilization rates of advanced imaging increased between 2002 and 2009 in the study population, with a great

  6. International Conference on Plasma Diagnostics. Slides, papers and posters of Plasma Diagnostics 2010

    International Nuclear Information System (INIS)

    Hartfuss, H.J.; Bonhomme, G.; Grisolia, C.; Hirsch, M.; Klos, Z.; Mazouffre, S.; Musielok, J.; Ratynskaya, S.; Sadowski, M.; Van de Sanden, R.; Sentis, M.; Stroth, U.; Tereshin, V.; Tichy, M.; Unterberg, B.; Weisen, H.; Zoletnik, S.

    2011-01-01

    Plasma diagnostics 2010 is an International Conference on Diagnostic Methods involved in Research and Applications of Plasmas, originating on combining the 5. German-Polish Conference on Plasma Diagnostics for Fusion and Applications and the 7. French-Polish Seminar on Thermal Plasma in Space and Laboratory. The Scientific Committee of 'Plasma 2007' decided to concentrate the attention of future conferences more on the diagnostic development and diagnostic interpretation in the fields of high and low temperature plasmas and plasma applications. It is aimed at involving all European activities in the fields. The Scientific Program will cover the fields from low temperature laboratory to fusion plasmas of various configurations as well as dusty and astrophysical plasmas and industrial plasma applications

  7. Lithium Battery Transient Response as a Diagnostic Tool

    Science.gov (United States)

    Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.

    2018-05-01

    Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.

  8. Litigations in diagnostic radiology

    International Nuclear Information System (INIS)

    Patil, Ranjit

    2014-01-01

    There are various regulatory bodies at the international and national level, which lay down norms for radiation protection. These are the International Commission for Radiation Protection (ICRP) the National Commission for Radiation Protection (NCRP) in America, and the Atomic Energy Regulatory Board (AERB) in India. These bodies recommend norms on various radiation issues. Radiography and radiology are two key tools for diagnosing and treating diseases. Recently there are concerns about the effect of ionizing radiation on man and the frequent use of diagnostic radiographs. The professionals are expected to conduct their actions according to guidelines which reflect new information and changing technology in diagnostic radiography. Failure to do so may have severe legal consequences. Patient protection is a matter of normal course but knowledge and awareness of the legal issues is important to avoid legal hassles. Implications of the radiation protection guidelines are discussed. (author)

  9. Evaluation of observed blast loading effects on NIF x-ray diagnostic collimators.

    Science.gov (United States)

    Masters, N D; Fisher, A; Kalantar, D; Prasad, R; Stölken, J S; Wlodarczyk, C

    2014-11-01

    We present the "debris wind" models used to estimate the impulsive load to which x-ray diagnostics and other structures are subject during National Ignition Facility experiments. These models are used as part of the engineering design process. Isotropic models, based on simulations or simplified "expanding shell" models, are augmented by debris wind multipliers to account for directional anisotropy. We present improvements to these multipliers based on measurements of the permanent deflections of diagnostic components: 4× for the polar direction and 2× within the equatorial plane-the latter relaxing the previous heuristic debris wind multiplier.

  10. A flexible simulator for training an early fault diagnostic system

    International Nuclear Information System (INIS)

    Marsiletti, M.; Santinelli, A.; Zuenkov, M.; Poletykin, A.

    1997-01-01

    An early fault diagnostic system has been developed addressed to timely trouble shooting in process plants during any operational modes. The theory of this diagnostic system is related with the usage of learning methods for automatic generation of knowledge bases. This approach enables the conversion of ''cause→effect'' relations into ''effect→possible-causes'' ones. The diagnostic rules are derived from the operation of a plant simulator according to a specific procedure. Flexibility, accuracy and high speed are the major characteristics of the training simulator, used to generate the diagnostic knowledge base. The simulator structure is very flexible, being based on LEGO code but allowing the use of practically any kind of FORTRAN routines (recently also ACSL macros has been introduced) as plant modules: this permits, when needed, a very accurate description of the malfunctions the diagnostic system should ''known''. The high speed is useful to shorten the ''learning'' phase of the diagnostic system. The feasibility of the overall system has been assessed, using as reference plant the conventional Sampierdarena (Italy) power station, that is a combined cycle plant dedicated to produce both electrical and heat power. The hardware configuration of this prototype system was made up of a network of a Hewlett-Packard workstation and a Digital VAX-Station. The paper illustrates the basic structure of the simulator used for this diagnostic system training purpose, as well as the theoretical background on which the diagnostic system is based. Some evidence of the effectiveness of the concept through the application to Sampierdarena 40 MW cogeneration plant is reported. Finally an outline of an ongoing application to a WWER-1000 plant is given; the operating system is, in this case, UNIX. (author)

  11. Regression models of reactor diagnostic signals

    International Nuclear Information System (INIS)

    Vavrin, J.

    1989-01-01

    The application is described of an autoregression model as the simplest regression model of diagnostic signals in experimental analysis of diagnostic systems, in in-service monitoring of normal and anomalous conditions and their diagnostics. The method of diagnostics is described using a regression type diagnostic data base and regression spectral diagnostics. The diagnostics is described of neutron noise signals from anomalous modes in the experimental fuel assembly of a reactor. (author)

  12. Numerical investigation of the effect of stenosis geometry on the coronary diagnostic parameters.

    Science.gov (United States)

    Kamangar, Sarfaraz; Kalimuthu, Govindaraju; Badruddin, Irfan Anjum; Badarudin, A; Ahmed, N J Salman; Khan, T M Yunus

    2014-01-01

    The present study deals with the functional severity of a coronary artery stenosis assessed by the fractional flow reserve (FFR). The effects of different geometrical shapes of lesion on the diagnostic parameters are unknown. In this study, 3D computational simulation of blood flow in three different geometrical shapes of stenosis (triangular, elliptical, and trapezium) is considered in steady and transient conditions for 70% (moderate), 80% (intermediate), and 90% (severe) area stenosis (AS). For a given percentage AS, the variation of diagnostic parameters which are derived from pressure drop across the stenosis was found in three different geometrical shapes of stenosis and it was observed that FFR is higher in triangular shape and lower in trapezium shape. The pressure drop coefficient (CDP) was higher in trapezium shape and lower in triangular model whereas the LFC shows opposite trend. From the clinical perspective, the relationship between percentage AS and FFR is linear and inversely related in all the three models. A cut-off value of 0.75 for FFR was observed at 76.5% AS in trapezium model, 79.5% in elliptical model, and 82.7% AS for the triangular shaped model. The misinterpretation of the functional severity of the stenosis is in the region of 76.5%-82.7 % AS from different shapes of stenosis models.

  13. Numerical Investigation of the Effect of Stenosis Geometry on the Coronary Diagnostic Parameters

    Directory of Open Access Journals (Sweden)

    Sarfaraz Kamangar

    2014-01-01

    Full Text Available The present study deals with the functional severity of a coronary artery stenosis assessed by the fractional flow reserve (FFR. The effects of different geometrical shapes of lesion on the diagnostic parameters are unknown. In this study, 3D computational simulation of blood flow in three different geometrical shapes of stenosis (triangular, elliptical, and trapezium is considered in steady and transient conditions for 70% (moderate, 80% (intermediate, and 90% (severe area stenosis (AS. For a given percentage AS, the variation of diagnostic parameters which are derived from pressure drop across the stenosis was found in three different geometrical shapes of stenosis and it was observed that FFR is higher in triangular shape and lower in trapezium shape. The pressure drop coefficient (CDP was higher in trapezium shape and lower in triangular model whereas the LFC shows opposite trend. From the clinical perspective, the relationship between percentage AS and FFR is linear and inversely related in all the three models. A cut-off value of 0.75 for FFR was observed at 76.5% AS in trapezium model, 79.5% in elliptical model, and 82.7% AS for the triangular shaped model. The misinterpretation of the functional severity of the stenosis is in the region of 76.5%-82.7 % AS from different shapes of stenosis models.

  14. Effects of a Multidisciplinary Approach to Improve Volume of Diagnostic Material in CT-Guided Lung Biopsies.

    Science.gov (United States)

    Ferguson, Philip E; Sales, Catherine M; Hodges, Dalton C; Sales, Elizabeth W

    2015-01-01

    Recent publications have emphasized the importance of a multidisciplinary strategy for maximum conservation and utilization of lung biopsy material for advanced testing, which may determine therapy. This paper quantifies the effect of a multidisciplinary strategy implemented to optimize and increase tissue volume in CT-guided transthoracic needle core lung biopsies. The strategy was three-pronged: (1) once there was confidence diagnostic tissue had been obtained and if safe for the patient, additional biopsy passes were performed to further increase volume of biopsy material, (2) biopsy material was placed in multiple cassettes for processing, and (3) all tissue ribbons were conserved when cutting blocks in the histology laboratory. This study quantifies the effects of strategies #1 and #2. This retrospective analysis comparing CT-guided lung biopsies from 2007 and 2012 (before and after multidisciplinary approach implementation) was performed at a single institution. Patient medical records were reviewed and main variables analyzed include biopsy sample size, radiologist, number of blocks submitted, diagnosis, and complications. The biopsy sample size measured was considered to be directly proportional to tissue volume in the block. Biopsy sample size increased 2.5 fold with the average total biopsy sample size increasing from 1.0 cm (0.9-1.1 cm) in 2007 to 2.5 cm (2.3-2.8 cm) in 2012 (Pstrategy to CT-guided lung biopsies was effective in significantly increasing tissue volume and number of blocks available for advanced diagnostic testing.

  15. Point-of-care diagnostics: market trends and growth drivers.

    Science.gov (United States)

    Rajan, Aruna; Glorikian, Harry

    2009-01-01

    There is a significant demand for in vitro diagnostic (IVD) testing to move closer to the patient point-of-care diagnostics [POC]), whether in the hospital, physician's office, rapid clinic or the home, effectively cutting time to results and helping patients make better informed decisions about their health. To analyze the point-of-care market and its trends and growth drivers. In 2007, POC made up 30% of the IVD market and is expected to grow at 9% a year. Although the overall POC market is expected to grow steadily, infectious POC is now the most attractive segment. Availability of rapid random access molecular diagnostic system for critical care infectious diseases such as MRSA and sepsis in the near future is likely to be a significant driver of infectious POC post 2012. Owing to the extraordinary increase in the cost of care, healthcare delivery is moving to increasingly decentralized settings such as rapid clinics and the home, driven by point-of-care diagnostics that provide accurate and directional results. We are evolving from the analog testing world to the digital testing world, where diagnosis is exact and therapy can be administered and be predictably effective.

  16. Nuclear aspects of diagnostics in RTO/RC ITER

    International Nuclear Information System (INIS)

    Walker, C.I.; Yamamoto, S.; Costley, A.; Kock, L. de; Ebisawa, K.; Janeschitz, G.; Khripunov, V.; Martin, E.; Vayakis, G.

    2000-01-01

    ITER (international thermonuclear experimental reactor) will be the first fusion device where the design of the plasma diagnostic systems will make extensive use of the materials and techniques developed in the nuclear technology field. The designs have to satisfy stringent requirements for tritium confinement, nuclear shielding and vacuum integrity. This paper introduces the requirements for diagnostics in the ITER long pulse, burning plasma environment, and addresses the impact of the reactor environment on the diagnostics and ancillary equipment. These systems necessarily require access to the plasma or first wall, which generally conflicts with the requirements of the basic machine. Holes are required through the first wall, primary shielding, containment boundaries and biological shielding. Components have a limited life and require maintenance. This paper describes the effect of the radiation environment on diagnostic design at different locations. Ex-vessel and in-vessel remote handling, hot cell refurbishment and tritium confinement are also described

  17. Electron–Cyclotron Laser Using Free-Electron Two-Quantum Stark Radiation in a Strong Uniform Axial Magnetic Field and an Alternating Axial Electric Field in a Voltage-Supplied Pill-Box Cavity

    International Nuclear Information System (INIS)

    Kim, S. H.

    2016-01-01

    We consider the radiation from the beam electrons traveling in a strong uniform axial magnetic field and an axial alternating electric field of wavelength λ_w generated by a voltage-supplied pill-box cavity. The beam electrons emit genuine laser radiation that propagates only in the axial direction through free-electron two-quantum Stark radiation. We find that laser radiation takes place only at the expense of the axial kinetic energy when λ_w ≪ c/(ω_c/γ), where ω_c/γ is the relativistic electron–cyclotron frequency. We formulate the laser power based on quantum-wiggler electrodynamics, and envision a laser of length 10 m with estimated power 0.1 GW/(kA) in the 10"−"4 cm wavelength range. (paper)

  18. Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sohi; Kim, Myung-Joon; Lee, Mi-Jung [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Kim, Dong Wook; Hong, Jung Hwa [Yonsei University College of Medicine, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2014-12-15

    Since children are more radio-sensitive than adults, there is a need to minimize radiation exposure during CT exams. To evaluate the effects of adaptive statistical iterative reconstruction (ASIR) on radiation dose reduction, image quality and diagnostic accuracy in pediatric abdominal CT. We retrospectively reviewed the abdominal CT examinations of 41 children (24 boys and 17 girls; mean age: 10 years) with a low-dose radiation protocol and reconstructed with ASIR (the ASIR group). We also reviewed routine-dose abdominal CT examinations of 41 age- and sex-matched controls reconstructed with filtered-back projection (control group). Image quality was assessed objectively as noise measured in the liver, spleen and aorta, as well as subjectively by three pediatric radiologists for diagnostic acceptability using a four-point scale. Radiation dose and objective image qualities of each group were compared with the paired t-test. Diagnostic accuracy was evaluated by reviewing follow-up imaging studies and medical records in 2012 and 2013. There was 46.3% dose reduction of size-specific dose estimates in ASIR group (from 13.4 to 7.2 mGy) compared with the control group. Objective noise was higher in the liver, spleen and aorta of the ASIR group (P < 0.001). However, the subjective image quality was average or superior in 84-100% of studies. Only one image was subjectively rated as unacceptable by one reviewer. There was only one case with interpretational error in the control group and none in the ASIR group. Use of the ASIR technique resulted in greater than a 45% reduction in radiation dose without impairing subjective image quality or diagnostic accuracy in pediatric abdominal CT, despite increased objective image noise. (orig.)

  19. Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT

    International Nuclear Information System (INIS)

    Bae, Sohi; Kim, Myung-Joon; Lee, Mi-Jung; Yoon, Choon-Sik; Kim, Dong Wook; Hong, Jung Hwa

    2014-01-01

    Since children are more radio-sensitive than adults, there is a need to minimize radiation exposure during CT exams. To evaluate the effects of adaptive statistical iterative reconstruction (ASIR) on radiation dose reduction, image quality and diagnostic accuracy in pediatric abdominal CT. We retrospectively reviewed the abdominal CT examinations of 41 children (24 boys and 17 girls; mean age: 10 years) with a low-dose radiation protocol and reconstructed with ASIR (the ASIR group). We also reviewed routine-dose abdominal CT examinations of 41 age- and sex-matched controls reconstructed with filtered-back projection (control group). Image quality was assessed objectively as noise measured in the liver, spleen and aorta, as well as subjectively by three pediatric radiologists for diagnostic acceptability using a four-point scale. Radiation dose and objective image qualities of each group were compared with the paired t-test. Diagnostic accuracy was evaluated by reviewing follow-up imaging studies and medical records in 2012 and 2013. There was 46.3% dose reduction of size-specific dose estimates in ASIR group (from 13.4 to 7.2 mGy) compared with the control group. Objective noise was higher in the liver, spleen and aorta of the ASIR group (P < 0.001). However, the subjective image quality was average or superior in 84-100% of studies. Only one image was subjectively rated as unacceptable by one reviewer. There was only one case with interpretational error in the control group and none in the ASIR group. Use of the ASIR technique resulted in greater than a 45% reduction in radiation dose without impairing subjective image quality or diagnostic accuracy in pediatric abdominal CT, despite increased objective image noise. (orig.)

  20. [Effectiveness of conventional diagnostic radiology and nuclear medicine in the treatment of pain from bone metastases].

    Science.gov (United States)

    Genovese, Eugenio Annibale; Mallardo, Vania; Vaccaro, Andrea; Santagata, Mario; Raucci, Antonio; D'Agosto, Gianfranco; Fontanarosa, Antonio; Schillirò, Francesco

    2013-01-01

    Bone is one of the most common metastasis sites from solid tumors. Bone pain due to metastatic neoplastic growth is due to tumor infiltration and expansion of bone membranes. Treatment of acute and chronic pain represents one of the greatest problems in clinical oncology, requiring a multidisciplinary approach. This review focuses on the effectiveness of conventional diagnostic radiology and nuclear medicine for the detection, management and treatment of pain from bone metastasis.

  1. Metrology of radiation doses in diagnostic radiology

    International Nuclear Information System (INIS)

    Leclet, H.

    2016-01-01

    This article recalls how to calculate effective and equivalent doses in radiology from the measured value of the absorbed dose. The 97/43 EURATOM directive defines irradiation standards for diagnostic radiology (NRD) as the value of the radiation dose received by the patient's skin when the diagnostic exam is performed. NRD values are standard values that can be exceeded only with right medical or technical reasons, they are neither limit values nor optimized values. The purpose of NRD values is to avoid the over-irradiation of patients and to homogenize radiologists' practices. French laws impose how and when radiologists have to calculate the radiation dose received by the patient's skin. The calculated values have to be compared with NRD values and any difference has to be justified. A table gives NRD values for all diagnostic exams. (A.C.)

  2. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  3. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  4. Diagnostic planning in JT-60 project

    International Nuclear Information System (INIS)

    Matoba, Tohru; Suzuki, Yasuo; Funahashi, Akimasa; Itagaki, Tokiyoshi

    1977-08-01

    The diagnostic plans of JT-60 were made along with design of the main machine. Basic requirements of the diagnostic program are (1) multiple measurement of respective plasma parameters, (2) efficient usage of the discharge, (3) capable data acquisition system, (4) high reliability of the diagnostic equipments, and (5) systematic development of new diagnostic techniques. Dimensions of the diagnostic ports were determined in detailed design of the vacuum vessel, anticipating the possible diagnostic methods. The proposed diagnostic systems and the plans are shown in table and figures respectively. Problems in the diagnostics are also described. (auth.)

  5. Cognitive and system factors contributing to diagnostic errors in radiology.

    Science.gov (United States)

    Lee, Cindy S; Nagy, Paul G; Weaver, Sallie J; Newman-Toker, David E

    2013-09-01

    In this article, we describe some of the cognitive and system-based sources of detection and interpretation errors in diagnostic radiology and discuss potential approaches to help reduce misdiagnoses. Every radiologist worries about missing a diagnosis or giving a false-positive reading. The retrospective error rate among radiologic examinations is approximately 30%, with real-time errors in daily radiology practice averaging 3-5%. Nearly 75% of all medical malpractice claims against radiologists are related to diagnostic errors. As medical reimbursement trends downward, radiologists attempt to compensate by undertaking additional responsibilities to increase productivity. The increased workload, rising quality expectations, cognitive biases, and poor system factors all contribute to diagnostic errors in radiology. Diagnostic errors are underrecognized and underappreciated in radiology practice. This is due to the inability to obtain reliable national estimates of the impact, the difficulty in evaluating effectiveness of potential interventions, and the poor response to systemwide solutions. Most of our clinical work is executed through type 1 processes to minimize cost, anxiety, and delay; however, type 1 processes are also vulnerable to errors. Instead of trying to completely eliminate cognitive shortcuts that serve us well most of the time, becoming aware of common biases and using metacognitive strategies to mitigate the effects have the potential to create sustainable improvement in diagnostic errors.

  6. Cost Implications of Value-Based Pricing for Companion Diagnostic Tests in Precision Medicine.

    Science.gov (United States)

    Zaric, Gregory S

    2016-07-01

    Many interpretations of personalized medicine, also referred to as precision medicine, include discussions of companion diagnostic tests that allow drugs to be targeted to those individuals who are most likely to benefit or that allow treatment to be designed in a way such that individuals who are unlikely to benefit do not receive treatment. Many authors have commented on the clinical and competitive implications of companion diagnostics, but there has been relatively little formal analysis of the cost implications of companion diagnostics, although cost reduction is often cited as a significant benefit of precision medicine. We investigate the potential impact on costs of precision medicine implemented through the use of companion diagnostics. We develop a framework in which the costs of companion diagnostic tests are determined by considerations of profit maximization and cost effectiveness. We analyze four scenarios that are defined by the incremental cost-effectiveness ratio of the new drug in the absence of a companion diagnostic test. We find that, in most scenarios, precision medicine strategies based on companion diagnostics should be expected to lead to increases in costs in the short term and that costs would fall only in a limited number of situations.

  7. Inhibition of collective spontaneous decay and superradiance in an ensemble of sufficiently high quantity of excited identical atoms

    International Nuclear Information System (INIS)

    Basharov, A.M.

    2011-01-01

    New effects of suppression of the collective spontaneous emission and superradiance have been predicted. At a certain number N of ensemble atoms, the Stark interaction with a vacuum field was shown as being high enough for the excited N-atom ensemble to be stabilized with respect to the collective decay. The result was derived analytically as a consequence of applying the quantum stochastic differential equations to the description of the atomic dynamics in vacuum, where the Stark interaction operator is expressed in terms of the quantum Poisson process. -- Highlights: → Enhancement of the Stark interaction of N atoms ensemble with vacuum, with N rising. → Representation of the Stark interaction as the quantum Poisson process. → Collective spontaneous decay and superradiance under the strong Stark interaction. → Inhibition of superradiance at a certain number of ensemble atoms. → Analysis of superradiance experiments in terms of inhibition of collective decay.

  8. Development of a diagnostic technique based on Cherenkov effect for measurements of fast electrons in fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Plyusnin, V. V.; Duarte, P.; Fernandes, H.; Silva, C. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Jakubowski, L.; Zebrowski, J.; Malinowski, K.; Rabinski, M.; Sadowski, M. J. [National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock (Poland)

    2012-08-15

    A diagnostic technique based on the Cherenkov effect is proposed for detection and characterization of fast (super-thermal and runaway) electrons in fusion devices. The detectors of Cherenkov radiation have been specially designed for measurements in the ISTTOK tokamak. Properties of several materials have been studied to determine the most appropriate one to be used as a radiator of Cherenkov emission in the detector. This technique has enabled the detection of energetic electrons (70 keV and higher) and the determination of their spatial and temporal variations in the ISTTOK discharges. Measurement of hard x-ray emission has also been carried out in experiments for validation of the measuring capabilities of the Cherenkov-type detector and a high correlation was found between the data of both diagnostics. A reasonable agreement was found between experimental data and the results of numerical modeling of the runaway electron generation in ISTTOK.

  9. ITER diagnostics ex-vessel engineering services

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, A.P., E-mail: arun.prakash@iter.org; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.; and others

    2013-10-15

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  10. ITER diagnostics ex-vessel engineering services

    International Nuclear Information System (INIS)

    Arumugam, A.P.; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.

    2013-01-01

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  11. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel 'V-plot' methodology to display accuracy values.

    Science.gov (United States)

    Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.

  12. Mobile diagnostics: next-generation technologies for in vitro diagnostics.

    Science.gov (United States)

    Shin, Joonchul; Chakravarty, Sudesna; Choi, Wooseok; Lee, Kyungyeon; Han, Dongsik; Hwang, Hyundoo; Choi, Jaekyu; Jung, Hyo-Il

    2018-03-26

    The emergence of a wide range of applications of smartphones along with advances in 'liquid biopsy' has significantly propelled medical research particularly in the field of in vitro diagnostics (IVD). Herein, we have presented a detailed analysis of IVD, its associated critical concerns and probable solutions. It also demonstrates the transition in terms of analytes from minimally invasive (blood) to non-invasive (urine, saliva and sweat) and depicts how the different features of a smartphone can be integrated for specific diagnostic purposes. This review basically highlights recent advances in the applications of smartphone-based biosensors in IVD taking into account the following factors: accuracy and portability; quantitative and qualitative analysis; and centralization and decentralization tests. Furthermore, the critical concerns and future direction of diagnostics based on smartphones are also discussed.

  13. Reflectometry diagnostics on TCV

    Science.gov (United States)

    Molina Cabrera, Pedro; Coda, Stefano; Porte, Laurie; Offeddu, Nicola; Tcv Team

    2017-10-01

    Both profile reflectometer and Doppler back-scattering (DBS) diagnostics are being developed for the TCV Tokamak using a steerable quasi-optical launcher and universal polarizers. First results will be presented. A pulse reflectometer is being developed to complement Thomson Scattering measurements of electron density, greatly increasing temporal resolution and also effectively enabling fluctuation measurements. Pulse reflectometry consists of sending short pulses of varying frequency and measuring the roundtrip group-delay with precise chronometers. A fast arbitrary waveform generator is used as a pulse source feeding frequency multipliers that bring the pulses to V-band. A DBS diagnostic is currently operational in TCV. DBS may be used to infer the perpendicular velocity and wave number spectrum of electron density fluctuations in the 3-15 cm-1 wave-number range. Off-the-shelf transceiver modules, originally used for VNA measurements, are being used in a Doppler radar configuration. See author list of S. Coda et al., 2017 Nucl. Fusion 57 102011.

  14. PRESSURE SHIFT AND GRAVITATIONAL REDSHIFT OF BALMER LINES IN WHITE DWARFS: REDISCUSSION

    Energy Technology Data Exchange (ETDEWEB)

    Halenka, Jacek; Olchawa, Wieslaw [Institute of Physics, University of Opole, ul. Oleska 48, 45-052, Opole (Poland); Madej, Jerzy [Astronomical Observatory, University of Warsaw, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Grabowski, Boleslaw, E-mail: halenka@uni.opole.pl, E-mail: wolch@uni.opole.pl, E-mail: jm@astrouw.edu.pl, E-mail: bgrab@uni.opole.pl [Wroclaw School of Information Technology WWSIS “Horyzont,” ul. Wejherowska 28, 54-239 Wroclaw (Poland)

    2015-08-01

    The Stark-induced shift and asymmetry, the so-called pressure shift (PS) of H{sub α} and H{sub β} Balmer lines in spectra of DA white dwarfs (WDs), have been examined in detail as masking effects in measurements of the gravitational redshift in WDs. The results are compared with our earlier ones from a quarter of a century ago. In these earlier papers, the standard, symmetrical Stark line profiles, as a dominant constituent of the Balmer line profiles but shifted as a whole by the PS effect, were applied to all spectrally active layers of the WD atmosphere. At present, in each of the WD layers, the Stark line profiles (especially of H{sub β}) are inherently asymmetrical and shifted due to the effects of strong inhomogeneity of the perturbing fields in plasma. To calculate the Stark line profiles in successive layers of the WD atmosphere we used the modified Full Computer Simulation Method, able to take adequately into account the complexity of local elementary quantum processes in plasma. In the case of the H{sub α} line, the present value of Stark-induced shift of the synthetic H{sub α} line profile is about half the previous one and it is negligible in comparison with the gravitational redshift. In the case of the H{sub β} line, the present value of Stark-induced shift of the synthetic H{sub β} line profile is about twice the previous one. The source of this extra shift is the asymmetry of H{sub β} peaks.

  15. Observation of instability-induced current redistribution in a spherical-torus plasma.

    Science.gov (United States)

    Menard, J E; Bell, R E; Gates, D A; Kaye, S M; LeBlanc, B P; Levinton, F M; Medley, S S; Sabbagh, S A; Stutman, D; Tritz, K; Yuh, H

    2006-09-01

    A motional Stark effect diagnostic has been utilized to reconstruct the parallel current density profile in a spherical-torus plasma for the first time. The measured current profile compares favorably with neoclassical theory when no large-scale magnetohydrodynamic instabilities are present in the plasma. However, a current profile anomaly is observed during saturated interchange-type instability activity. This apparent anomaly can be explained by redistribution of neutral beam injection current drive and represents the first observation of interchange-type instabilities causing such redistribution. The associated current profile modifications contribute to sustaining the central safety factor above unity for over five resistive diffusion times, and similar processes may contribute to improved operational scenarios proposed for ITER.

  16. Simulation and interpretation of ion beam diagnostics on PBFA-II

    International Nuclear Information System (INIS)

    Mehlhorn, T.A.; Nelson, W.E.; Maenchen, J.E.; Stygar, W.A.; Ruiz, C.L.; Lockner, T.R.; Johnson, D.J.

    1988-03-01

    Ion diode and beam focusing experiments are in progress on PBFA-II working towards an ultimate goal of significant burn of an ICF pellet. Beam diagnostics on these experiments include a Thomson parabola, K/sub alpha/ x-ray pinhole cameras, filtered ion pinhole cameras, and a magnetic spectrometer. We are developing two new computer programs to simulate and interpret the data obtained from these diagnostics. VIDA is a VAX-based program that manipulates and unfolds data from digitized particle and x-ray diagnostic images. VIDA operations include: image display, background substraction, relative-to-absolute coordinate transformations, and image projection into the beam reference frame. PICDIAG allows us to study the effects of time-dependent ion focusing on the performance of ion beam diagnostics. 10 refs., 5 figs

  17. Diagnosis demystified: CT as diagnostic tool in endodontics

    Science.gov (United States)

    Shruthi, Nagaraja; Sreenivasa Murthy, B V; Sundaresh, K J; Mallikarjuna, Rachappa

    2013-01-01

    Diagnosis in endodontics is usually based on clinical and radiographical presentations, which are only empirical methods. The role of healing profession is to apply knowledge and skills towards maintaining and restoring the patient's health. Recent advances in imaging technologies have added to correct interpretation and diagnosis. CT is proving to be an effective tool in solving endodontic mysteries through its three-dimensional visualisation. CT imaging offers many diagnostic advantages to produce reconstructed images in selected projection and low-contrast resolution far superior to that of all other X-ray imaging modalities. This case report is an endeavour towards effective treatment planning of cases with root fracture, root resorption using spiral CT as an adjuvant diagnostic tool. PMID:23814212

  18. Plasma diagnostics for the compact ignition tokamak

    International Nuclear Information System (INIS)

    Medley, S.S.; Young, K.M.

    1988-06-01

    The primary mission of the Compact Ignition Tokamak (CIT) is to study the physics of alpha-particle heating in an ignited D-T plasma. A burn time of about 10 /tau//sub E/ is projected in a divertor configuration with baseline machine design parameters of R=2.10 m, 1=0.65 m, b=1.30 m, I/sub p/=11 MA, B/sub T/=10 T and 10-20 MW of auxiliary rf heating. Plasma temperatures and density are expected to reach T/sub e/(O) /approximately/20 keV, T/sub i/(O) /approximately/30 keV, and n/sub e/(O) /approximately/ 1 /times/ 10 21 m/sup /minus/3/. The combined effects of restricted port access to the plasma, the presence of severe neutron and gamma radiation backgrounds, and the necessity for remote of in-cell components create challenging design problems for all of the conventional diagnostic associated with tokamak operations. In addition, new techniques must be developed to diagnose the evolution in space, time, and energy of the confined alpha distribution as well as potential plasma instabilities driven by collective alpha-particle effects. The design effort for CIT diagnostics is presently in the conceptual phase with activity being focused on the selection of a viable diagnostic set and the identification of essential research and development projects to support this process. A review of these design issues and other aspects impacting the selection of diagnostic techniques for the CIT experiment will be presented. 28 refs., 10 figs., 2 tabs

  19. Diagnostic Development on NSTX

    International Nuclear Information System (INIS)

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-01-01

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted

  20. Picosecond image-converter diagnostics

    International Nuclear Information System (INIS)

    Schelev, M.Ya.

    1975-01-01

    A brief review is presented of the improvements in picosecond image-converter diagnostics carried out since the previous Congress in 1972. The account is given under the following headings: picosecond image converter cameras for visible and x-ray radiation diagnostics; Nd:glass and ruby mode-locked laser measurements; x-ray plasma emission diagnostics; computer treatment of pictures produced by picosecond cameras. (U.K.)

  1. NEW STRONG-LINE ABUNDANCE DIAGNOSTICS FOR H II REGIONS: EFFECTS OF κ-DISTRIBUTED ELECTRON ENERGIES AND NEW ATOMIC DATA

    Energy Technology Data Exchange (ETDEWEB)

    Dopita, Michael A.; Sutherland, Ralph S.; Nicholls, David C.; Kewley, Lisa J.; Vogt, Frédéric P. A., E-mail: Michael.Dopita@anu.edu.au [Research School of Astronomy and Astrophysics, Australian National University, Cotter Rd., Weston ACT 2611 (Australia)

    2013-09-01

    Recently, Nicholls et al., inspired by in situ observations of solar system astrophysical plasmas, suggested that the electrons in H II regions are characterized by a κ-distribution of energies rather than a simple Maxwell-Boltzmann distribution. Here, we have collected together new atomic data within a modified photoionization code to explore the effects of both the new atomic data and the κ-distribution on the strong-line techniques used to determine chemical abundances in H II regions. By comparing the recombination temperatures (T {sub rec}) with the forbidden line temperatures (T {sub FL}), we conclude that κ ∼ 20. While representing only a mild deviation from equilibrium, this result is sufficient to strongly influence abundances determined using methods that depend on measurements of the electron temperature from forbidden lines. We present a number of new emission line ratio diagnostics that cleanly separate the two parameters determining the optical spectrum of H II regions—the ionization parameter q or U and the chemical abundance, 12+log(O/H). An automated code to extract these parameters is presented. Using the homogeneous data set from van Zee et al., we find self-consistent results between all of these different diagnostics. The systematic errors between different line ratio diagnostics are much smaller than those found in the earlier strong-line work. Overall, the effect of the κ-distribution on the strong-line abundances derived solely on the basis of theoretical models is rather small.

  2. The role of neural networks in reactor diagnostics and control

    International Nuclear Information System (INIS)

    Pazsit, I.; Kitamura, M.

    1997-01-01

    Reactor diagnostics and core diagnostics in particular, is an inverse task, just as most other diagnostics. One measures some physical parameter at some position, or the fluctuation thereof, which is given rise by the fluctuation of another parameter, presumably at a different position. In neutron noise diagnostics, the measured quantity is the neutron noise, whereas the cause, fluctuations of the core material, is called the open-quotes noise sourceclose quotes. The relationship between the cause (noise source) and the induced noise (effect) is determined by the physics of the process and can usually be described by a theory. This means that the direct task, calculation of the noise from the noise source, can always be achieved. In diagnostics, however, the process starts from the back end, i.e. one observes the effect of some cause. The task is to infer the cause (noise source) from the effect (induced noise), which is an inverse task (sometimes also called unfolding). The situation is very much similar even regarding control problems. The system state is described by a vector in the parameter space. When it deviates from the desired one, the control parameters need to be changed to bring the system into the desired state. The computation of the change in the state vector, due to a change in the control vector, can be calculated with no difficulty in principle. The control requires however the inverse task to be performed, i.e. to determine which changes of the control vector would bring the state vector into the desired state

  3. LHD neutron diagnostics

    International Nuclear Information System (INIS)

    Isobe, M.; Ogawa, K.; Kobuchi, T.

    2015-01-01

    The Large Helical Device (LHD) project will step into a next stage, i.e. experiment by using deuterium gases after two years of preparation. A comprehensive set of neutron and γ-ray diagnostics is going to be installed on the LHD towards extension of energetic-particle (EP) physics research in heliotron plasmas. Conceptual design of fusion products diagnostics for the LHD was made in late 1990s. After conclusion of agreements for the LHD deuterium experiment with local government bodies, development of FPs diagnostics has begun lately. Because there are a lot of tasks to do, all Japan fusion neutron and γ-ray diagnostics team has been organized in the collaboration framework of National Institute for Fusion Science. FPs diagnostics system on the LHD will consist of 1) wide dynamic range neutron flux monitor (NFM), 2) neutron activation system (NAS), 3) vertical neutron camera (VNC). In addition to these, we are developing a directional scintillating fiber detector, an artificial diamond detector and a γ-ray scintillation detector for confinement study of MeV ions. A neutron energy spectrometer prototype is also being developed and tested in KSTAR. In this paper, roles of NFM, NAS and VNC and current status of implementation onto the LHD are briefly described. (author)

  4. Plasma diagnostics for tokamaks and stellarators

    International Nuclear Information System (INIS)

    Stott, P.E.; Sanchez, J.

    1994-01-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Sattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma

  5. Thyroid diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Scriba, P C; Boerner, W; Emrich, S; Gutekunst, R; Herrmann, J; Horn, K; Klett, M; Krueskemper, H L; Pfannenstiel, P; Pickardt, C R

    1985-03-01

    None of the in-vitro and in-vivo methods listed permits on unambiguous diagnosis when applied alone, owing to the fact that similar or even identical findings are obtained for various individual parameters in different thyroid diseases. Further, especially the in-vitro tests are also subject to extrathyroidal effects which may mask the typical findings. The limited and varying specificity and sensitivity of the tests applied, as well as the falsification of results caused by the patients' idiosyncracies and the methodology, make it necessary to interpret and evaluate the in-vivo and in-vitro findings only if the clinical situation (anamnesis and physical examination) is known. For maximum diagnostic quality of the tests, the initial probability of the assumed type of thyroid disease must be increased (formulation of the clinical problem). The concepts of exclusion diagnosis and identification must be distinguished as well as the diagnosis of functional disturbances on the one hand and of thyroid diseases on the other. Both of this requires a qualified, specific and detailed anamnesis and examination procedure, and the clinical examination remains the obligatory basis of clinical diagnostics. In case of inexplicable discrepancies between the clinical manifestations and the findings obtained with specific methods, or between the findings obtained with a specific method, the patient should be referred to an expert institution, or the expert institution should be consulted.

  6. Thyroid diagnostics

    International Nuclear Information System (INIS)

    Scriba, P.C.; Boerner, W.; Emrich, S.; Gutekunst, R.; Herrmann, J.; Horn, K.; Klett, M.; Krueskemper, H.L.; Pfannenstiel, P.; Pickardt, C.R.; Reiners, C.; Reinwein, D.; Schleusener, H.

    1985-01-01

    None of the in-vitro and in-vivo methods listed permits on unambiguous diagnosis when applied alone, owing to the fact that similar or even identical findings are obtained for various individual parameters in different thyroid diseases. Further, especially the in-vitro tests are also subject to extrathyroidal effects which may mask the typical findings. The limited and varying specificity and sensitivity of the tests applied, as well as the falsification of results caused by the patients' idiosyncracies and the methodology, make it necessary to interpret and evaluate the in-vivo and in-vitro findings only if the clinical situation (anamnesis and physical examination) is known. For maximum diagnostic quality of the tests, the initial probability of the assumed type of thyroid disease must be increased (formulation of the clinical problem). The concepts of exclusion diagnosis and identification must be distinguished as well as the diagnosis of functional disturbances on the one hand and of thyroid diseases on the other. Both of this requires a qualified, specific and detailed anamnesis and examination procedure, and the clinical examination remains the obligatory basis of clinical diagnostics. In case of inexplicable discrepancies between the clinical manifestations and the findings obtained with specific methods, or between the findings obtained with a specific method, the patient should be referred to an expert institution, or the expert institution should be consulted. (orig./MG) [de

  7. Clinical diagnostic ultrasound

    International Nuclear Information System (INIS)

    Barnett, E.; Morley, P.

    1986-01-01

    This textbook on diagnostic ultrasound covers the main systems, with emphasis being placed on the clinical application of diagnostic ultrasound in everyday practice. It provides not only a textbook for postgraduates (particularly FRCR candidates), but also a reference work for practitioners of clinical ultrasound and clinicians generally

  8. The Role of Radiology in the Diagnostic Process: Information, Communication, and Teamwork.

    Science.gov (United States)

    Larson, David B; Langlotz, Curtis P

    2017-11-01

    The diagnostic radiology process represents a partnership between clinical and radiology teams. As such, breakdowns in interpersonal interactions and communication can result in patient harm. We explore the role of radiology in the diagnostic process, focusing on key concepts of information and communication, as well as key interpersonal interactions of teamwork, collaboration, and collegiality, all based on trust. We propose 10 principles to facilitate effective information flow in the diagnostic process.

  9. Plasma diagnostics on large tokamaks

    International Nuclear Information System (INIS)

    Orlinskij, D.V.; Magyar, G.

    1988-01-01

    The main tasks of the large tokamaks which are under construction (T-15 and Tore Supra) and of those which have already been built (TFTR, JET, JT-60 and DIII-D) together with their design features which are relevant to plasma diagnostics are briefly discussed. The structural features and principal characteristics of the diagnostic systems being developed or already being used on these devices are also examined. The different diagnostic methods are described according to the physical quantities to be measured: electric and magnetic diagnostics, measurements of electron density, electron temperature, the ion components of the plasma, radiation loss measurements, spectroscopy of impurities, edge diagnostics and study of plasma stability. The main parameters of the various diagnostic systems used on the six large tokamaks are summarized in tables. (author). 351 refs, 44 figs, 22 tabs

  10. Outcomes of non-invasive diagnostic modalities for the detection of coronary artery disease: network meta-analysis of diagnostic randomised controlled trials

    Science.gov (United States)

    Siontis, George CM; Mavridis, Dimitris; Greenwood, John P; Coles, Bernadette; Nikolakopoulou, Adriani; Jüni, Peter; Salanti, Georgia

    2018-01-01

    Abstract Objective To evaluate differences in downstream testing, coronary revascularisation, and clinical outcomes following non-invasive diagnostic modalities used to detect coronary artery disease. Design Systematic review and network meta-analysis. Data sources Medline, Medline in process, Embase, Cochrane Library for clinical trials, PubMed, Web of Science, SCOPUS, WHO International Clinical Trials Registry Platform, and Clinicaltrials.gov. Eligibility criteria for selecting studies Diagnostic randomised controlled trials comparing non-invasive diagnostic modalities in patients presenting with symptoms suggestive of low risk acute coronary syndrome or stable coronary artery disease. Data synthesis A random effects network meta-analysis synthesised available evidence from trials evaluating the effect of non-invasive diagnostic modalities on downstream testing and patient oriented outcomes in patients with suspected coronary artery disease. Modalities included exercise electrocardiograms, stress echocardiography, single photon emission computed tomography-myocardial perfusion imaging, real time myocardial contrast echocardiography, coronary computed tomographic angiography, and cardiovascular magnetic resonance. Unpublished outcome data were obtained from 11 trials. Results 18 trials of patients with low risk acute coronary syndrome (n=11 329) and 12 trials of those with suspected stable coronary artery disease (n=22 062) were included. Among patients with low risk acute coronary syndrome, stress echocardiography, cardiovascular magnetic resonance, and exercise electrocardiograms resulted in fewer invasive referrals for coronary angiography than coronary computed tomographic angiography (odds ratio 0.28 (95% confidence interval 0.14 to 0.57), 0.32 (0.15 to 0.71), and 0.53 (0.28 to 1.00), respectively). There was no effect on the subsequent risk of myocardial infarction, but estimates were imprecise. Heterogeneity and inconsistency were low. In patients with

  11. A genetic programming approach for Burkholderia Pseudomallei diagnostic pattern discovery

    Science.gov (United States)

    Yang, Zheng Rong; Lertmemongkolchai, Ganjana; Tan, Gladys; Felgner, Philip L.; Titball, Richard

    2009-01-01

    Motivation: Finding diagnostic patterns for fighting diseases like Burkholderia pseudomallei using biomarkers involves two key issues. First, exhausting all subsets of testable biomarkers (antigens in this context) to find a best one is computationally infeasible. Therefore, a proper optimization approach like evolutionary computation should be investigated. Second, a properly selected function of the antigens as the diagnostic pattern which is commonly unknown is a key to the diagnostic accuracy and the diagnostic effectiveness in clinical use. Results: A conversion function is proposed to convert serum tests of antigens on patients to binary values based on which Boolean functions as the diagnostic patterns are developed. A genetic programming approach is designed for optimizing the diagnostic patterns in terms of their accuracy and effectiveness. During optimization, it is aimed to maximize the coverage (the rate of positive response to antigens) in the infected patients and minimize the coverage in the non-infected patients while maintaining the fewest number of testable antigens used in the Boolean functions as possible. The final coverage in the infected patients is 96.55% using 17 of 215 (7.4%) antigens with zero coverage in the non-infected patients. Among these 17 antigens, BPSL2697 is the most frequently selected one for the diagnosis of Burkholderia Pseudomallei. The approach has been evaluated using both the cross-validation and the Jack–knife simulation methods with the prediction accuracy as 93% and 92%, respectively. A novel approach is also proposed in this study to evaluate a model with binary data using ROC analysis. Contact: z.r.yang@ex.ac.uk PMID:19561021

  12. Dynamic Visualization of SNS Diagnostics Summary Report and System Status

    CERN Document Server

    Blokland, Willem; Long, Cary D; Murphy, Darryl J; Purcell, John D; Sundaram, Madhan

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based running Embedded Windows XP and LabVIEW. The diagnostics instruments communicate with the control system using the Channel Access (CA) protocol of the Experimental Physics and Industrial Control System (EPICS). This paper describes the Diagnostics Group's approach to collecting data from the instruments, processing it, and presenting live in a summarized way over the web. Effectively, adding a supervisory level to the diagnostics instruments. One application of this data mining is the "Diagnostics Status Page" that summarizes the insert-able devices, transport efficiencies, and the mode of the accelerator in a compact webpage. The displays on the webpage change automatically to show the latest and/o...

  13. Plasma diagnostics for tokamaks and stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Stott, P E; Sanchez, J

    1994-07-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: Magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Scattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma. (Author) 451 refs.

  14. Spectral Effects on Fast Wave Core Heating and Current Drive

    International Nuclear Information System (INIS)

    Phillips, C.K.; Bell, R.E.; Berry, L.A.; Bonoli, P.T.; Harvey, R.W.; Hosea, J.C.; Jaeger, E.F.; LeBlanc, B.P.; Ryan, P.M.; Taylor, G.; Valeo, E.J.; Wilson, J.R.; Wright, J.C.; Yuh, H. and the NSTX Team

    2009-01-01

    Recent results obtained with high harmonic fast wave (HHFW) heating and current drive (CD) on NSTX strongly support the hypothesis that the onset of perpendicular fast wave propagation right at or very near the launcher is a primary cause for a reduction in core heating efficiency at long wavelengths that is also observed in ICRF heating experiments in numerous tokamaks. A dramatic increase in core heating efficiency was first achieved in NSTX L-mode helium majority plasmas when the onset for perpendicular wave propagation was moved away from the antenna and nearby vessel structures. Efficient core heating in deuterium majority L mode and H mode discharges, in which the edge density is typically higher than in comparable helium majority plasmas, was then accomplished by reducing the edge density in front of the launcher with lithium conditioning and avoiding operational points prone to instabilities. These results indicate that careful tailoring of the edge density profiles in ITER should be considered to limit rf power losses to the antenna and plasma facing materials. Finally, in plasmas with reduced rf power losses in the edge regions, the first direct measurements of high harmonic fast wave current drive were obtained with the motional Stark effect (MSE) diagnostic. The location and radial dependence of HHFW CD measured by MSE are in reasonable agreement with predictions from both full wave and ray tracing simulations

  15. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  16. Nordic working group for medical x-ray diagnostics: Diagnostic reference levels within xray diagnostics - experiences in the Nordic countries

    International Nuclear Information System (INIS)

    Leitz, W.; Groen, P.; Servomaa, A.; Einarsson, G.; Olerud, H.

    2003-01-01

    Medical x-ray diagnostics is one of the few applications of ionising radiation where people are irradiated on purpose. The strategy for radiation protection is also different compared to that in other areas that have the zero-alternative as its ultimate goal, meaning that no human beings at all are exposed in these practices. The focus in x-ray diagnostics concerning radiation protection is justification and optimisation. Optimisation implies that the examination is performed in such a way that the radiation dose is as small as possible without jeopardising the diagnostic security. X- ray diagnostics is a complex method where many technical parameters and methodology factors together are interacting in the determination of radiation dose and image quality. The optimisation process is not a simple and uncomplicated procedure, this difficulty is reflected in many international and national surveys showing a large spread of patient doses for one and the same type of examination. The concept diagnostic reference levels (DRL) has been introduced as a tool for reducing this wide distribution that is obviously indicating a lack of optimisation, and for cutting the highest radiation doses. In this presentation the concept for DRL and the experience gained in the Nordic countries with DRL are described. (orig.)

  17. The diagnostic value of the premature ejaculation diagnostic tool and its association with intravaginal ejaculatory latency time.

    Science.gov (United States)

    Kam, Sung Chul; Han, Deok Hyun; Lee, Sung Won

    2011-03-01

    Premature ejaculation (PE) is the most prevalent male ejaculation disorder. The premature ejaculation diagnostic tool (PEDT) was developed to systematically apply the DSM-IV-TR criteria in diagnostic PE. To evaluate the diagnostic value of the PEDT and its association with intravaginal ejaculatory latency time (IELT). (i) Korean validation of PEDT: data was collected from men interviewed by one of the two clinical experts, who made a diagnostic of present or absence of PE, using DSM-IV-TR criteria. A total of 103 patients with PE and 100 men without PE were enrolled into the study and requested to complete the PEDT; and (ii) The correlation between IELT and PEDT: 200 participants were enrolled and each participant was asked to make out PEDT. All participants were requested to measure IELT. Validity and reliability of the PEDT and its association with IELT. The geometric mean IELT of the PE group was 115.37 ± 78.14 seconds. The number of men reporting IELTs of 2 minutes were 28 (28.6%), 29 (29.6%), and 41 (41.8%), respectively. The Cronbach's alpha score was calculated as 0.93, showing adequate internal consistency. The test-retest correlation coefficients of each item were higher than 0.72 and the correlation coefficients of the total score was 0.88. (P IELT showed an adequate negative correlation. (ρ = -0.77, P IELT ≤ 2 minutes) and IELT showed a negative correlation. (ρ = -0.6, P < 0.0001) The PEDT was highly effective in detecting the presence of PE. The result of our study supports its validity as a diagnostic tool in the clinical setting. © 2010 International Society for Sexual Medicine.

  18. Plasma diagnostic reflectometry

    International Nuclear Information System (INIS)

    Cohen, B.I.; Afeyan, B.B.; Garrison, J.C.; Kaiser, T.B.; Luhmann, N.C. Jr.; Domier, C.W.; Chou, A.E.; Baang, S.

    1996-01-01

    Theoretical and experimental studies of plasma diagnostic reflectometry have been undertaken as a collaborative research project between the Lawrence Livermore National Laboratory (LLNL) and the University of California Department of Applied Science Plasma Diagnostics Group under the auspices of the Laboratory Directed Research and Development Program at LLNL. Theoretical analyses have explored the basic principles of reflectometry to understand its limitations, to address specific gaps in the understanding of reflectometry measurements in laboratory experiments, and to explore extensions of reflectometry such as ultra-short-pulse reflectometry. The theory has supported basic laboratory reflectometry experiments where reflectometry measurements can be corroborated by independent diagnostic measurements

  19. Diagnostic procedure on brake pad assembly based on Young's modulus estimation

    International Nuclear Information System (INIS)

    Chiariotti, P; Santolini, C; Tomasini, E P; Martarelli, M

    2013-01-01

    Quality control of brake pads is an important issue, since the pad is a key component of the braking system. Typical damage of a brake pad assembly is the pad–backing plate detachment that affects and modifies the mechanical properties of the whole system. The most sensitive parameter to the damage is the effective Young's modulus, since the damage induces a decrease of the pad assembly stiffness and therefore of its effective Young's modulus: indeed its variation could be used for diagnostic purposes. The effective Young's modulus can be estimated from the first bending resonance frequency identified from the frequency response function measured on the pad assembly. Two kinds of excitation methods, i.e. conventional impulse excitation and magnetic actuation, will be presented and two different measurement sensors, e.g. laser Doppler vibrometer and microphone, analyzed. The robustness of the effective Young's modulus as a diagnostic feature will be demonstrated in comparison to the first bending resonance frequency, which is more sensitive to geometrical dimensions. Variability in the sample dimension, in fact, will induce a variation of the resonance frequency which could be mistaken for damage. The diagnostic approach has been applied to a set of undamaged and damaged pad assemblies showing good performance in terms of damage identification. The environmental temperature can be an important interfering input for the diagnostic procedure, since it influences the effective Young's modulus of the assembly. For that reason, a test at different temperatures in the range between 15 °C and 30 °C has been performed, evidencing that damage identification technique is efficient at any temperature. The robustness of the Young's modulus as a diagnostic feature with respect to damping is also presented. (paper)

  20. Lectures in plasma diagnostics

    International Nuclear Information System (INIS)

    Hutchinson, I.H.

    1990-06-01

    This paper discusses the following topics on plasma diagnostics: Electric probes in flowing and magnetized plasmas; Electron cyclotron emission absorption; Magnetic diagnostics; Spectroscopy; and Thomson Scattering

  1. Anisotropic spin–orbit stark effect in cubic semiconductors without an inversion center

    International Nuclear Information System (INIS)

    Alekseev, P. S.

    2015-01-01

    The effect of external electric and magnetic fields on shallow donor levels in a semiconductor of the T d crystallographic class is analyzed. Application of an electric field eliminates the symmetry of the donor potential with respect to space inversion; as a result, corrections from the momentum-odd spin–orbit Dresselhaus term appear in the donor levels. In a strong electric field, such corrections determine the anisotropy of spin splitting of the donor levels relative to the directions of the external fields in the crystallographic coordinate system. Analytic expressions are derived for the spin splitting anisotropy for various relations between the magnitudes of the magnetic and electric fields. The results of this study can be used to determine the Dresselhaus spin–orbit interaction constant by a new method (in experiments on spin splitting of donor levels)

  2. Anisotropic spin–orbit stark effect in cubic semiconductors without an inversion center

    Energy Technology Data Exchange (ETDEWEB)

    Alekseev, P. S., E-mail: pavel.alekseev@mail.ioffe.ru [Russian Academy of Sciences, Ioffe Physicotechnical Institute (Russian Federation)

    2015-09-15

    The effect of external electric and magnetic fields on shallow donor levels in a semiconductor of the T{sub d} crystallographic class is analyzed. Application of an electric field eliminates the symmetry of the donor potential with respect to space inversion; as a result, corrections from the momentum-odd spin–orbit Dresselhaus term appear in the donor levels. In a strong electric field, such corrections determine the anisotropy of spin splitting of the donor levels relative to the directions of the external fields in the crystallographic coordinate system. Analytic expressions are derived for the spin splitting anisotropy for various relations between the magnitudes of the magnetic and electric fields. The results of this study can be used to determine the Dresselhaus spin–orbit interaction constant by a new method (in experiments on spin splitting of donor levels)

  3. Cost-effectiveness analysis of rapid diagnostic test, microscopy and syndromic approach in the diagnosis of malaria in Nigeria: implications for scaling-up deployment of ACT

    Directory of Open Access Journals (Sweden)

    Onwujekwe Obinna E

    2009-11-01

    Full Text Available Abstract Background The diagnosis and treatment of malaria is often based on syndromic presentation (presumptive treatment and microscopic examination of blood films. Treatment based on syndromic approach has been found to be costly, and contributes to the development of drug resistance, while microscopic diagnosis of malaria is time-consuming and labour-intensive. Also, there is lack of trained microscopists and reliable equipment especially in rural areas of Nigeria. However, although rapid diagnostic tests (RDTs have improved the ease of appropriate diagnosis of malaria diagnosis, the cost-effectiveness of RDTs in case management of malaria has not been evaluated in Nigeria. The study hence compares the cost-effectiveness of RDT versus syndromic diagnosis and microscopy. Methods A total of 638 patients with fever, clinically diagnosed as malaria (presumptive malaria by health workers, were selected for examination with both RDT and microscopy. Patients positive on RDT received artemisinin-based combination therapy (ACT and febrile patients negative on RDT received an antibiotic treatment. Using a decision tree model for a hypothetical cohort of 100,000 patients, the diagnostic alternatives considered were presumptive treatment (base strategy, RDT and microscopy. Costs were based on a consumer and provider perspective while the outcome measure was deaths averted. Information on costs and malaria epidemiology were locally generated, and along with available data on effectiveness of diagnostic tests, adherence level to drugs for treatment, and drug efficacy levels, cost-effectiveness estimates were computed using TreeAge programme. Results were reported based on costs and effects per strategy, and incremental cost-effectiveness ratios. Results The cost-effectiveness analysis at 43.1% prevalence level showed an incremental cost effectiveness ratio (ICER of 221 per deaths averted between RDT and presumptive treatment, while microscopy is dominated

  4. Effects of job stress on hypertension among medical diagnostic X-ray workers in China

    International Nuclear Information System (INIS)

    Zhao Zhigang; Wang Jixian; Zhao Yongcheng; Zhang Wei

    2004-01-01

    Objective: To study the relation between job stress and hypertension among medical diagnostic x-ray workers in China. Methods: A total of 264 confirmed cases of hypertension were selected among medical diagnostic X-ray workers from 10 provinces and cities. A case-control study with 1:2 matched pair was conducted. Job stress was defined according to Siegrist effort-reward imbalance model. Results: High imbalance ,high overcommitment and severe work environment were associated with enhanced hypertension risk significantly. The OR was 1.848 (P=0.018), 2.058 (P=0.000) and 1.797 (P=0.008) for imbalance, overcommitment and severe work environment, respectively. After controlling other risk factors, the relation still remained significant. Conclusion: The main work-related risk factors causing hypertension among diagnostic X-ray workers are effort-reward imbalance, overcommitment and severe work environment. (authors)

  5. Development of JT-60 diagnostics system

    International Nuclear Information System (INIS)

    Suzuki, Yasuo

    1988-01-01

    The various kinds of plasma diagnostics have been developed and utilized in the JT-60 experiments. The features of JT-60 diagnostics system and the historical proceeding of the development are described in this paper. Taking account of the design consideration, JT-60 diagnostics system is sorted out into eight groups, which include six diagnostics systems, the data processing system and diagnostics supporting system. The all devices in the JT-60 diagnostics system were instrumented on schedule in the end of the fiscal year of 1985 and have contributed to JT-60 experiments. (author)

  6. Advantages of digital imaging for radiological diagnostic

    International Nuclear Information System (INIS)

    Trapero, M. A.; Gonzalez, S.; Albillos, J. C.; Martel, J.; Rebollo, M.

    2006-01-01

    The advantages and limitations of radiological digital images in comparison with analogic ones are analyzed. We discuss three main topics: acquisition, post-procedure manipulation, and visualization, archive and communication. Digital acquisition with computed radiology systems present a global sensitivity very close to conventional film for diagnostic purposes. However, flat panel digital systems seems to achieve some advantages in particular clinical situations. A critical issue is the radiation dose-reduction that can be accomplished without reducing image quality nor diagnostic exactitude. The post-procedure manipulation allows, particularly in multiplanar modalities like CT or MR, to extract all implicit diagnostic information in the images: Main procedures are multiplanar and three-dimensional reformations, dynamic acquisitions, functional studies and image fusion. The use of PACS for visualization, archive and communication of images, improves the effectiveness and the efficiency of the workflow, allows a more comfortable diagnosis for the radiologist and gives way to improvements in the communication of images, allowing tele consulting and the tele radiology. (Author) 6 refs

  7. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel ‘V-plot’ methodology to display accuracy values

    Science.gov (United States)

    Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Background Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test’s performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. Methods and findings We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Cholrapid and Cholgold) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). Conclusion No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard. PMID:29387424

  8. Characterization of diagnostic hole-closure in Z-pinch driven hohlraums

    International Nuclear Information System (INIS)

    Baker, K. L.; Porter, J. L.; Ruggles, L. E.; Chandler, G. A.; Deeney, Chris; Vargas, M.; Moats, Ann; Struve, Ken; Torres, J.; McGurn, J. S.

    2000-01-01

    In this article we investigate the partial closure of diagnostic holes in Z-pinch driven hohlraums. These hohlraums differ from current laser-driven hohlraums in a number of ways such as their larger size, greater x-ray drive energy, and lower temperature. Although the diameter of the diagnostic holes on these Z-pinch driven hohlraums can be much greater than their laser-driven counterparts, 4 mm in diameter or larger, radiation impinges on the wall material surrounding the hole for the duration of the Z pinch, nearly 100 ns. This incident radiation causes plasma to ablate from the hohlraum walls surrounding the diagnostic hole and partially obscure this diagnostic hole. This partial obscuration reduces the effective area over which diagnostics view the hohlraum's radiation. This reduction in area can lead to an underestimation of the wall temperature when nonimaging diagnostics such as x-ray diodes and bolometers are used to determine power and later to infer a wall temperature. In this article we describe the techniques used to characterize the hole-closure in these hohlraums and present the experimental measurements of this process. (c) 2000 American Institute of Physics

  9. Characterization of diagnostic hole-closure in Z-pinch driven hohlraums

    Energy Technology Data Exchange (ETDEWEB)

    Baker, K. L. [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Porter, J. L. [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Ruggles, L. E. [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Chandler, G. A. [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Deeney, Chris [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Vargas, M. [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Moats, Ann [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Struve, Ken [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Torres, J. [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); McGurn, J. S. [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States)] (and others)

    2000-02-01

    In this article we investigate the partial closure of diagnostic holes in Z-pinch driven hohlraums. These hohlraums differ from current laser-driven hohlraums in a number of ways such as their larger size, greater x-ray drive energy, and lower temperature. Although the diameter of the diagnostic holes on these Z-pinch driven hohlraums can be much greater than their laser-driven counterparts, 4 mm in diameter or larger, radiation impinges on the wall material surrounding the hole for the duration of the Z pinch, nearly 100 ns. This incident radiation causes plasma to ablate from the hohlraum walls surrounding the diagnostic hole and partially obscure this diagnostic hole. This partial obscuration reduces the effective area over which diagnostics view the hohlraum's radiation. This reduction in area can lead to an underestimation of the wall temperature when nonimaging diagnostics such as x-ray diodes and bolometers are used to determine power and later to infer a wall temperature. In this article we describe the techniques used to characterize the hole-closure in these hohlraums and present the experimental measurements of this process. (c) 2000 American Institute of Physics.

  10. Integration of interactive three-dimensional image post-processing software into undergraduate radiology education effectively improves diagnostic skills and visual-spatial ability

    Energy Technology Data Exchange (ETDEWEB)

    Rengier, Fabian, E-mail: fabian.rengier@web.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Häfner, Matthias F. [University Hospital Heidelberg, Department of Radiation Oncology, Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Unterhinninghofen, Roland [Karlsruhe Institute of Technology (KIT), Institute for Anthropomatics, Department of Informatics, Adenauerring 2, 76131 Karlsruhe (Germany); Nawrotzki, Ralph; Kirsch, Joachim [University of Heidelberg, Institute of Anatomy and Cell Biology, Im Neuenheimer Feld 307, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Giesel, Frederik L. [University of Heidelberg, Institute of Anatomy and Cell Biology, Im Neuenheimer Feld 307, 69120 Heidelberg (Germany); University Hospital Heidelberg, Department of Nuclear Medicine, Im Neuenheimer Feld 400, 69120 Heidelberg (Germany)

    2013-08-15

    Purpose: Integrating interactive three-dimensional post-processing software into undergraduate radiology teaching might be a promising approach to synergistically improve both visual-spatial ability and radiological skills, thereby reducing students’ deficiencies in image interpretation. The purpose of this study was to test our hypothesis that a hands-on radiology course for medical students using interactive three-dimensional image post-processing software improves radiological knowledge, diagnostic skills and visual-spatial ability. Materials and methods: A hands-on radiology course was developed using interactive three-dimensional image post-processing software. The course consisted of seven seminars held on a weekly basis. The 25 participating fourth- and fifth-year medical students learnt to systematically analyse cross-sectional imaging data and correlated the two-dimensional images with three-dimensional reconstructions. They were instructed by experienced radiologists and collegiate tutors. The improvement in radiological knowledge, diagnostic skills and visual-spatial ability was assessed immediately before and after the course by multiple-choice tests comprising 64 questions each. Wilcoxon signed rank test for paired samples was applied. Results: The total number of correctly answered questions improved from 36.9 ± 4.8 to 49.5 ± 5.4 (p < 0.001) which corresponded to a mean improvement of 12.6 (95% confidence interval 9.9–15.3) or 19.8%. Radiological knowledge improved by 36.0% (p < 0.001), diagnostic skills for cross-sectional imaging by 38.7% (p < 0.001), diagnostic skills for other imaging modalities – which were not included in the course – by 14.0% (p = 0.001), and visual-spatial ability by 11.3% (p < 0.001). Conclusion: The integration of interactive three-dimensional image post-processing software into undergraduate radiology education effectively improves radiological reasoning, diagnostic skills and visual-spatial ability, and thereby

  11. Integration of interactive three-dimensional image post-processing software into undergraduate radiology education effectively improves diagnostic skills and visual-spatial ability

    International Nuclear Information System (INIS)

    Rengier, Fabian; Häfner, Matthias F.; Unterhinninghofen, Roland; Nawrotzki, Ralph; Kirsch, Joachim; Kauczor, Hans-Ulrich; Giesel, Frederik L.

    2013-01-01

    Purpose: Integrating interactive three-dimensional post-processing software into undergraduate radiology teaching might be a promising approach to synergistically improve both visual-spatial ability and radiological skills, thereby reducing students’ deficiencies in image interpretation. The purpose of this study was to test our hypothesis that a hands-on radiology course for medical students using interactive three-dimensional image post-processing software improves radiological knowledge, diagnostic skills and visual-spatial ability. Materials and methods: A hands-on radiology course was developed using interactive three-dimensional image post-processing software. The course consisted of seven seminars held on a weekly basis. The 25 participating fourth- and fifth-year medical students learnt to systematically analyse cross-sectional imaging data and correlated the two-dimensional images with three-dimensional reconstructions. They were instructed by experienced radiologists and collegiate tutors. The improvement in radiological knowledge, diagnostic skills and visual-spatial ability was assessed immediately before and after the course by multiple-choice tests comprising 64 questions each. Wilcoxon signed rank test for paired samples was applied. Results: The total number of correctly answered questions improved from 36.9 ± 4.8 to 49.5 ± 5.4 (p < 0.001) which corresponded to a mean improvement of 12.6 (95% confidence interval 9.9–15.3) or 19.8%. Radiological knowledge improved by 36.0% (p < 0.001), diagnostic skills for cross-sectional imaging by 38.7% (p < 0.001), diagnostic skills for other imaging modalities – which were not included in the course – by 14.0% (p = 0.001), and visual-spatial ability by 11.3% (p < 0.001). Conclusion: The integration of interactive three-dimensional image post-processing software into undergraduate radiology education effectively improves radiological reasoning, diagnostic skills and visual-spatial ability, and thereby

  12. Start-effect measurement of high FEL [free-electron laser] electric fields in MTX [Microwave Tokamak Experiment] by laser-aided particle-probe spectroscopy

    International Nuclear Information System (INIS)

    Oda, T.; Takiyama, K.; Odajima, K.; Ohasa, K.; Shiho, M.; Mizuno, K.; Foote, J.H.; Nilson, D.G.

    1990-01-01

    We are constructing a diagnostic system to measure the electric field (>100 kV/cm) of a free-electron laser (FEL) beam when injected into the plasma of the Microwave Tokamak Experiment (MTX). The apparatus allows a crossed-beam measurement, with 2-cm spatial resolution in the plasma, involving the FEL beam (with 140-GHz, ∼1-GW ECH pulses), a neutral-helium beam, and a dye-laser beam. After the laser beam pumps metastable helium atoms to higher excited states, their decay light is detected by an efficient optical system. Because of the Stark effect arising from the FEL electric field (rvec E), a forbidden transition can be strongly induced. The intensity of emitted light resulting from the forbidden transition is proportional to E 2 . Because photon counting rates are estimated to be low, extra effort is made to minimize background and noise levels. It is possible that the lower rvec E of an MTX gyrotron-produced ECH beam with its longer-duration pulses can also be measured using this method. Other applications of the apparatus described here may include measurements of ion temperature (using charge-exchange recombination), edge-density fluctuations, and core impurity concentrations

  13. Radiological diagnostics of skeletal tumors

    International Nuclear Information System (INIS)

    Uhl, M.; Herget, G.W.

    2008-01-01

    The book contains contributions concerning the following topics: 1. introduction and fundamentals: WHO classification of bone tumors, imaging diagnostics and their function; localization, typical clinical and radiological criteria, TNM classification and status classification, invasive tumor diagnostics; 2. specific tumor diagnostics: chondrogenic bone tumors, osseous tumors, connective tissue bony tumors, osteoclastoma, osteomyelogenic bone tumors, vascular bone tumors, neurogenic bone tumors, chordoma; adamantinoma of the long tubular bone; tumor-like lesions, bony metastases, bone granulomas, differential diagnostics: tumor-like lesions

  14. Multidisciplinary molecular diagnostics: the 9th European meeting on molecular diagnostics.

    Science.gov (United States)

    Loonen, Anne J M; Schuurman, Rob; van den Brule, Adriaan J C

    2016-01-01

    This report presents a summary of the 9th European Meeting on Molecular Diagnostics held in Noordwijk, The Netherlands, 14-16 October 2015. This 3-day conference covered many relevant topics in the field of molecular diagnostics in humans, including infectious disease, oncology, outbreak management, population-based cancer screening, standardization and quality control, chronic diseases and pharmacogenetics. Beyond these different areas, shared values are new technologies and novel technical and clinical applications. Approximately 450 participants, the majority coming from European countries, attended the meeting. Besides high quality scientific presentations, more than 35 diagnostic companies presented their latest innovations, altogether in an informal and inspiring scientific ambience.

  15. Diagnostic characteristics of lethal prostate cancer

    DEFF Research Database (Denmark)

    Helgstrand, John Thomas; Røder, Martin Andreas; Klemann, Nina

    2017-01-01

    eventually died from PCa. PATIENTS AND METHODS: Based on the national database, the Danish Prostate Cancer Registry, a nationwide population-based study of all 19,487 men who died from PCa in Denmark between 1995 and 2013 was conducted. Trends in median survival and trends in age, prostate-specific antigen......BACKGROUND: The diagnostic characteristics of men who eventually die from prostate cancer (PCa) and the extent to which early diagnostic strategies have affected these characteristics are unclear. We aimed to investigate trends in survival and clinical presentation at diagnosis in men who...... significantly over time, parallelled by an increase in median survival. Taken together, this indicates a lead-time effect on survival, which presently, however, is not substantial enough to result in a reduced PCa-specific mortality....

  16. Study for the design method of multi-agent diagnostic system to improve diagnostic performance for similar abnormality

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents on industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning such as support vector machine is expected to detect the occurrence of abnormality in a plant early and correctly. There were reported that these diagnostic machines has high accuracy to diagnose the operating state of industrial plant under mono abnormality occurrence. But the each diagnostic machine on the multi-agent diagnostic system may misdiagnose similar abnormalities as a same abnormality if abnormalities to diagnose increases. That causes that a single diagnostic machine may show higher diagnostic performance than one of multi-agent diagnostic system because decision-making considering with misdiagnosis is difficult. Therefore, we study the design method for multi-agent diagnostic system to diagnose similar abnormality correctly. This method aimed to realize automatic generation of diagnostic system where the generation process and location of diagnostic machines are optimized to diagnose correctly the similar abnormalities which are evaluated from the similarity of process signals by statistical method. This paper explains our design method and reports the result evaluated our method applied to the process data of the fast-breeder reactor Monju

  17. Benchmarking Diagnostic Algorithms on an Electrical Power System Testbed

    Science.gov (United States)

    Kurtoglu, Tolga; Narasimhan, Sriram; Poll, Scott; Garcia, David; Wright, Stephanie

    2009-01-01

    Diagnostic algorithms (DAs) are key to enabling automated health management. These algorithms are designed to detect and isolate anomalies of either a component or the whole system based on observations received from sensors. In recent years a wide range of algorithms, both model-based and data-driven, have been developed to increase autonomy and improve system reliability and affordability. However, the lack of support to perform systematic benchmarking of these algorithms continues to create barriers for effective development and deployment of diagnostic technologies. In this paper, we present our efforts to benchmark a set of DAs on a common platform using a framework that was developed to evaluate and compare various performance metrics for diagnostic technologies. The diagnosed system is an electrical power system, namely the Advanced Diagnostics and Prognostics Testbed (ADAPT) developed and located at the NASA Ames Research Center. The paper presents the fundamentals of the benchmarking framework, the ADAPT system, description of faults and data sets, the metrics used for evaluation, and an in-depth analysis of benchmarking results obtained from testing ten diagnostic algorithms on the ADAPT electrical power system testbed.

  18. Optical fibres for fusion plasma diagnostics systems

    International Nuclear Information System (INIS)

    Brichard, B.

    2005-01-01

    The condition to achieve and maintain the ignition of a thermonuclear fusion plasma ignition calls for the construction of a large scale fusion reactor, namely ITER. This reactor is designed to deliver an average fusion power of 500 MW. The burning of fusion plasma at such high power level will release a tremendous amount of energy in the form of particle fluxes and ionising radiation. This energy release, primarily absorbed by the plasma facing components, can significantly degrade the performances of the plasma diagnostic equipment surrounding the machine. To ensure a correct operation of the Tokamak we need to develop highly radiation-resistance devices. In plasma diagnostic systems, optical fibre is viewed as a convenient tool to transport light from the plasma edge to the diagnostic area. Radiation affects the optical performances of the fibre mainly by the occurrence of radiation-induced absorption and luminescence. Both effects degrade the light signal used for plasma diagnostic. SCK-CEN is currently assessing radiation-resistant glasses for optical fibres and is developing the associated qualification procedure. The main objectives of this study were to increase the lifetime of optical components in high radiation background and to develop a radiation resistance optical fibre capable to operate in the radiation background of ITER

  19. Active beam spectroscopy for ITER

    International Nuclear Information System (INIS)

    Von Hellermann, M.; Giroud, C.; Jaspers, R.; Hawkes, N.C.; Mullane, M.O.; Zastrow, K.D.; Krasilnikov, A.; Tugarinov, S.; Lotte, P.; Malaquias, A.; Rachlew, E.

    2003-01-01

    The latest status of 'Active Beam' related spectroscopy aspects as part of the ITER diagnostic scenario is presented. A key issue of the proposed scheme is based on the concept that in order to achieve the ultimate goal of global data consistency, all particles involved, that is, intrinsic and seeded impurity ions as well as helium ash ions and bulk plasma ions and also the plasma background data (e.g. magnetic and electric fields, electron density and temperature profiles) need to be addressed. A further sensible step in this direction is the decision of exploiting both a dedicated low-energy, low-power diagnostic beam (DNB, 2.2 MW 100 keV/amu) as well as the high-power, high-energy heating beams (HNB, 17 MW 500 keV/amu) for maximum diagnostic information. The authors report some new aspects referring to the use of DNB for motional Stark effect (MSE) where the main idea is to treat both beams (HNB and DNB) as potential diagnostic tools with complementary roles. The equatorial ports for the DNB promise excellent spatial resolution, however, the angles are less favourable for a polarimetric MSE exploitation. HNB can be used as probe beam for diagnosing slowing-down fusion alpha with a birth energy of 3,5 MeV

  20. Microbial Diagnostic Array Workstation (MDAW: a web server for diagnostic array data storage, sharing and analysis

    Directory of Open Access Journals (Sweden)

    Chang Yung-Fu

    2008-09-01

    Full Text Available Abstract Background Microarrays are becoming a very popular tool for microbial detection and diagnostics. Although these diagnostic arrays are much simpler when compared to the traditional transcriptome arrays, due to the high throughput nature of the arrays, the data analysis requirements still form a bottle neck for the widespread use of these diagnostic arrays. Hence we developed a new online data sharing and analysis environment customised for diagnostic arrays. Methods Microbial Diagnostic Array Workstation (MDAW is a database driven application designed in MS Access and front end designed in ASP.NET. Conclusion MDAW is a new resource that is customised for the data analysis requirements for microbial diagnostic arrays.