WorldWideScience

Sample records for standard diagnostic tool

  1. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    A. Yu. Galkin

    2015-04-01

    Full Text Available In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO 13485 “Medical devices. Quality management system. Regulatory requirements”, and DSTU ISO/IEC 17025 “General requirements for the competence of testing and calibration laboratories”. Similar requirements of the State Pharmacopoeia of Ukraine which are used for drug standardization can not be directly applied to the medical devises for in vitro diagnostics due to a number of features, namely, the serological diagnosis products pre-designed to determine the unknown concentration of a particular analyte in a biological material, the diagnostic kits has to include the control samples (internal standard systems that need to be calibrated. It was determined following parameters of bioanalytical standardization and validation characterization for of qualitative (semi quantitative test-kits for serological diagnosis: precision (convergence, intralaboratory precision and reproducibility, diagnostic and analytical specificity, diagnostic sensitivity. It’s necessary to inspect additional parameters for quantitative test-kits such as accuracy (precision, linearity, analytical sensitivity and range.

  2. Standardization of diagnostic PCR for the detection of foodborne pathogens

    DEFF Research Database (Denmark)

    Malorny, B.; Tassios, P.T.; Radstrom, P.

    2003-01-01

    In vitro amplification of nucleic acids using the polymerase chain reaction (PCR) has become, since its discovery in the 1980s, a powerful diagnostic tool for the analysis of microbial infections as well as for the analysis of microorganisms in food samples. However, despite its potential, PCR has...... neither gained wide acceptance in routine diagnostics nor been widely incorporated in standardized methods. Lack of validation and standard protocols, as well as variable quality of reagents and equipment, influence the efficient dissemination of PCR methodology from expert research laboratories to end......-user laboratories. Moreover, the food industry understandably requires and expects officially approved standards. Recognizing this, in 1999, the European Commission approved the research project, FOOD-PCR (http://www.PCR.dk), which aims to validate and standardize the use of diagnostic PCR for the detection...

  3. SNS Diagnostics Tools for Data Acquisition and Display

    CERN Document Server

    Sundaram, Madhan; Long, Cary D

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1.0 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based and will run Windows for its OS and LabVIEW as its programming language. The diagnostics platform as well as other control systems and operator consoles use the Channel Access (CA) protocol of the Experimental Physics and Industrial Control System (EPICS) to communicate. This paper describes the tools created to evaluate the diagnostic instrument using our standard programming environment, LabVIEW. The tools are based on the LabVIEW Channel Access library and can run on Windows, Linux, and Mac OS X. The data-acquisition tool uses drop and drag to select process variables organized by instrument, accelerator component, or beam parameters. The data can be viewed on-line and logged to disk for later ...

  4. Image analysis as an adjunct to manual HER-2 immunohistochemical review: a diagnostic tool to standardize interpretation.

    LENUS (Irish Health Repository)

    Dobson, Lynne

    2010-07-01

    AIMS: Accurate determination of HER-2 status is critical to identify patients for whom trastuzumab treatment will be of benefit. Although the recommended primary method of evaluation is immunohistochemistry, numerous reports of variability in interpretation have raised uncertainty about the reliability of results. Recent guidelines have suggested that image analysis could be an effective tool for achieving consistent interpretation, and this study aimed to assess whether this technology has potential as a diagnostic support tool. METHODS AND RESULTS: Across a cohort of 275 cases, image analysis could accurately classify HER-2 status, with 91% agreement between computer-aided classification and the pathology review. Assessment of the continuity of membranous immunoreactivity in addition to intensity of reactivity was critical to distinguish between negative and equivocal cases and enabled image analysis to report a lower referral rate of cases for confirmatory fluorescence in situ hybridization (FISH) testing. An excellent concordance rate of 95% was observed between FISH and the automated review across 136 informative cases. CONCLUSIONS: This study has validated that image analysis can robustly and accurately evaluate HER-2 status in immunohistochemically stained tissue. Based on these findings, image analysis has great potential as a diagnostic support tool for pathologists and biomedical scientists, and may significantly improve the standardization of HER-2 testing by providing a quantitative reference method for interpretation.

  5. Polymerase chain reaction: A molecular diagnostic tool in periodontology

    Science.gov (United States)

    Maheaswari, Rajendran; Kshirsagar, Jaishree Tukaram; Lavanya, Nallasivam

    2016-01-01

    This review discusses the principles of polymerase chain reaction (PCR) and its application as a diagnostic tool in periodontology. The relevant MEDLINE and PubMed indexed journals were searched manually and electronically by typing PCR, applications of PCR, PCR in periodontics, polymorphism studies in periodontitis, and molecular techniques in periodontology. The searches were limited to articles in English language and the articles describing PCR process and its relation to periodontology were collected and used to prepare a concise review. PCR has now become a standard diagnostic and research tool in periodontology. Various studies reveal that its sensitivity and specificity allow it as a rapid, efficient method of detecting, identifying, and quantifying organism. Different immune and inflammatory markers can be identified at the mRNA expression level, and also the determination of genetic polymorphisms, thus providing the deeper insight into the mechanisms underlying the periodontal disease. PMID:27143822

  6. Diagnostic test accuracy of nutritional tools used to identify undernutrition in patients with colorectal cancer: a systematic review.

    Science.gov (United States)

    Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela

    2015-05-15

    Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive

  7. Comparative guide to emerging diagnostic tools for large commercial HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Hannah; Piette, Mary Ann

    2001-05-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

  8. Comparing Diagnostic Tools in Personality Disorders

    Directory of Open Access Journals (Sweden)

    Emel AKGUN AKTAS

    2016-04-01

    Full Text Available Personality Disorder is defined as; continually self experience and behavioral pattern which has great variations of individual cultural normal expectations. Several diagnostic tools were developed for diagnosing personality disorders. In our study consistency of different diagnostic tools used for thhe diagnosis of personality disorders were evaluated. 39 inpatients diagnosed as personality disorder from Diskapi Yildirim Beyazit Traning and Reseach Hospital were recruited into the study. Psychotic patients are excluded from the study. Sociodemographic Information Form, MMPI and PBQ scales were given all the patients. Both PBQ personality subscales and MMPI PD scales were compared with semi-structured SCID-II interview diagnoses. Findings suggest less correlation than expected. Relatively higher correlation was found between PBQ personality subscales and MMPI-PD. Most common psychiatric comorbid disorder was depression. These findings suggest that further studies are needed for the development of diagnostic tools which take the differences of self report scales and clinical evalution into consideration. Beside, the differences of the categorical and dimensional classification of personality disorders should be bear in mind in evaluation of this patient group. [JCBPR 2016; 5(1.000: 22-27

  9. Diagnostic tools in ocular allergy.

    Science.gov (United States)

    Leonardi, A; Doan, S; Fauquert, J L; Bozkurt, B; Allegri, P; Marmouz, F; Rondon, C; Jedrzejczak, M; Hellings, P; Delgado, L; Calder, V

    2017-10-01

    Ocular allergy (OA) includes a group of common and less frequent hypersensitivity disorders frequently misdiagnosed and not properly managed. The diagnosis of OA is usually based on clinical history and signs and symptoms, with the support of in vivo and in vitro tests when identification of the specific allergen is required. To date, no specific test is available for the diagnosis of the whole spectrum of the different forms of OA. The lack of recommendations on diagnosis of OA is considered a medical need not only for allergists but also for ophthalmologists. This position paper aims to provide a comprehensive overview of the currently available tools for diagnosing OA to promote a common nomenclature and procedures to be used by different specialists. Questionnaires, sign and symptom grading scales, tests, and potential biomarkers for OA are reviewed. We also identified several unmet needs in the diagnostic tools to generate interest, increase understanding, and inspire further investigations. Tools, recommendations, and algorithms for the diagnosis of OA are proposed for use by both allergists and ophthalmologists. Several unmet needs in the diagnostic tools should be further improved by specific clinical research in OA. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  10. Diagnostic Accuracy of Fall Risk Assessment Tools in People With Diabetic Peripheral Neuropathy

    Science.gov (United States)

    Pohl, Patricia S.; Mahnken, Jonathan D.; Kluding, Patricia M.

    2012-01-01

    Background Diabetic peripheral neuropathy affects nearly half of individuals with diabetes and leads to increased fall risk. Evidence addressing fall risk assessment for these individuals is lacking. Objective The purpose of this study was to identify which of 4 functional mobility fall risk assessment tools best discriminates, in people with diabetic peripheral neuropathy, between recurrent “fallers” and those who are not recurrent fallers. Design A cross-sectional study was conducted. Setting The study was conducted in a medical research university setting. Participants The participants were a convenience sample of 36 individuals between 40 and 65 years of age with diabetic peripheral neuropathy. Measurements Fall history was assessed retrospectively and was the criterion standard. Fall risk was assessed using the Functional Reach Test, the Timed “Up & Go” Test, the Berg Balance Scale, and the Dynamic Gait Index. Sensitivity, specificity, positive and negative likelihood ratios, and overall diagnostic accuracy were calculated for each fall risk assessment tool. Receiver operating characteristic curves were used to estimate modified cutoff scores for each fall risk assessment tool; indexes then were recalculated. Results Ten of the 36 participants were classified as recurrent fallers. When traditional cutoff scores were used, the Dynamic Gait Index and Functional Reach Test demonstrated the highest sensitivity at only 30%; the Dynamic Gait Index also demonstrated the highest overall diagnostic accuracy. When modified cutoff scores were used, all tools demonstrated improved sensitivity (80% or 90%). Overall diagnostic accuracy improved for all tests except the Functional Reach Test; the Timed “Up & Go” Test demonstrated the highest diagnostic accuracy at 88.9%. Limitations The small sample size and retrospective fall history assessment were limitations of the study. Conclusions Modified cutoff scores improved diagnostic accuracy for 3 of 4 fall risk

  11. Comparative guide to emerging diagnostic tools for large commercial HVAC systems; TOPICAL

    International Nuclear Information System (INIS)

    Friedman, Hannah; Piette, Mary Ann

    2001-01-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool

  12. Image standards in Tissue-Based Diagnosis (Diagnostic Surgical Pathology

    Directory of Open Access Journals (Sweden)

    Vollmer Ekkehard

    2008-04-01

    Full Text Available Abstract Background Progress in automated image analysis, virtual microscopy, hospital information systems, and interdisciplinary data exchange require image standards to be applied in tissue-based diagnosis. Aims To describe the theoretical background, practical experiences and comparable solutions in other medical fields to promote image standards applicable for diagnostic pathology. Theory and experiences Images used in tissue-based diagnosis present with pathology – specific characteristics. It seems appropriate to discuss their characteristics and potential standardization in relation to the levels of hierarchy in which they appear. All levels can be divided into legal, medical, and technological properties. Standards applied to the first level include regulations or aims to be fulfilled. In legal properties, they have to regulate features of privacy, image documentation, transmission, and presentation; in medical properties, features of disease – image combination, human – diagnostics, automated information extraction, archive retrieval and access; and in technological properties features of image acquisition, display, formats, transfer speed, safety, and system dynamics. The next lower second level has to implement the prescriptions of the upper one, i.e. describe how they are implemented. Legal aspects should demand secure encryption for privacy of all patient related data, image archives that include all images used for diagnostics for a period of 10 years at minimum, accurate annotations of dates and viewing, and precise hardware and software information. Medical aspects should demand standardized patients' files such as DICOM 3 or HL 7 including history and previous examinations, information of image display hardware and software, of image resolution and fields of view, of relation between sizes of biological objects and image sizes, and of access to archives and retrieval. Technological aspects should deal with image

  13. Changes in IEC standards related to diagnostic radiology

    International Nuclear Information System (INIS)

    Porubszky, T.; Barsai, J.

    2007-01-01

    Complete test of publication follows. Purposes. Technical Committee TC62 of International Electrotechnical Commission (IEC) deals with medical electrical equipment (i.e. medical devices using electricity). Standardization concerning diagnostic radiology equipment is task of its Sub-Committee SC62B. An outlook of its activities and present situation, and especially of radiation protection aspects, is given. Materials and methods. Third edition of basic safety standard for medical electrical equipment IEC 60601-1 was issued in 2005. Elaboration of new collateral and particular standards - applicable together with it - is in progress. These standards are generally at the same time also European - EN - and national standards. There is a great importance of radiation protection in diagnostic X-ray equipment. Collateral standard IEC 6060-1-3 about it was at first issued in 1994. Rapid development of imaging technology demands updating of requirements. SC62B in 2003 founded a maintenance team MT37 for preparation of the second edition of this standard. According to new safety philosophy of IEC all modality specific requirements are to be collected in 'safety and essential performance' particular standards. A new working group WG42 - founded in 2006 - elaborates a new particular standard IEC 60601-2-54 for radiographic and radioscopic equipment. Maintenance team MT32 deals with safety and performance standards for X-ray tube assemblies. The authors actively participate in these activities. Results and discussion. Present and future system of diagnostic radiology IEC standards and some interesting details are presented. Conclusions. International standards - although they are not 'obligatory' - are generally the basis of safety and performance certification of diagnostic radiology equipment and often also of their quality assurance.

  14. Overview of erosion–deposition diagnostic tools for the ITER-Like Wall in the JET tokamak

    International Nuclear Information System (INIS)

    Rubel, M.; Coad, J.P.; Widdowson, A.; Matthews, G.F.; Esser, H.G.; Hirai, T.; Likonen, J.; Linke, J.; Lungu, C.P.; Mayer, M.; Pedrick, L.; Ruset, C.

    2013-01-01

    This paper presents scientific and technical issues related to the development of erosion–deposition diagnostic tools for JET operated with the ITER-Like Wall: beryllium and tungsten marker tiles and several types of wall probes installed in the main chamber and in the divertor. Markers tiles are the standard limiter and divertor components additionally coated first with a thin sandwich of Ni–Be and Mo–W for, beryllium and tungsten markers, respectively. Both types of markers are embedded in regular arrays of limiter and divertor tiles. Coated W–Be probes are also inserted in the Be-covered Inconel cladding tiles on the central column. Other types of erosion–deposition diagnostic tools are: rotating collectors, deposition traps, louver clips, quartz microbalance and mirrors for the First Mirror Test at JET for ITER. The specific role of these tools is discussed in detail

  15. Standardization of positive controls in diagnostic immunohistochemistry

    DEFF Research Database (Denmark)

    Torlakovic, Emina E; Nielsen, Søren; Francis, Glenn

    2015-01-01

    Diagnostic immunohistochemistry (dIHC) has been practiced for several decades, with an ongoing expansion of applications for diagnostic use, and more recently for detection of prognostic and predictive biomarkers. However, standardization of practice has yet to be achieved, despite significant...

  16. XML Diagnostics Description Standard

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Varandas, C.; Lister, J.; Yonekawa, I.

    2006-01-01

    A standard for the self-description of fusion plasma diagnostics will be presented, based on the Extensible Markup Language (XML). The motivation is to maintain and organise the information on all the components of a laboratory experiment, from the hardware to the access security, to save time and money when problems arises. Since there is no existing standard to organise this kind of information, every Association stores and organises each experiment in different ways. This can lead to severe problems when the organisation schema is poorly documented or written in national languages. The exchange of scientists, researchers and engineers between laboratories is a common practice nowadays. Sometimes they have to install new diagnostics or to update existing ones and frequently they lose a great deal of time trying to understand the currently installed system. The most common problems are: no documentation available; the person who understands it has left; documentation written in the national language. Standardisation is the key to solving all the problems mentioned. From the commercial information on the diagnostic (component supplier; component price) to the hardware description (component specifications; drawings) to the operation of the equipment (finite state machines) through change control (who changed what and when) and internationalisation (information at least in the native language and in English), a common XML schema will be proposed. This paper will also discuss an extension of these ideas to the self-description of ITER plant systems, since the problems will be identical. (author)

  17. Evaluating online diagnostic decision support tools for the clinical setting.

    Science.gov (United States)

    Pryor, Marie; White, David; Potter, Bronwyn; Traill, Roger

    2012-01-01

    Clinical decision support tools available at the point of care are an effective adjunct to support clinicians to make clinical decisions and improve patient outcomes. We developed a methodology and applied it to evaluate commercially available online clinical diagnostic decision support (DDS) tools for use at the point of care. We identified 11 commercially available DDS tools and assessed these against an evaluation instrument that included 6 categories; general information, content, quality control, search, clinical results and other features. We developed diagnostically challenging clinical case scenarios based on real patient experience that were commonly missed by junior medical staff. The evaluation was divided into 2 phases; an initial evaluation of all identified and accessible DDS tools conducted by the Clinical Information Access Portal (CIAP) team and a second phase that further assessed the top 3 tools identified in the initial evaluation phase. An evaluation panel consisting of senior and junior medical clinicians from NSW Health conducted the second phase. Of the eleven tools that were assessed against the evaluation instrument only 4 tools completely met the DDS definition that was adopted for this evaluation and were able to produce a differential diagnosis. From the initial phase of the evaluation 4 DDS tools scored 70% or more (maximum score 96%) for the content category, 8 tools scored 65% or more (maximum 100%) for the quality control category, 5 tools scored 65% or more (maximum 94%) for the search category, and 4 tools score 70% or more (maximum 81%) for the clinical results category. The second phase of the evaluation was focused on assessing diagnostic accuracy for the top 3 tools identified in the initial phase. Best Practice ranked highest overall against the 6 clinical case scenarios used. Overall the differentiating factor between the top 3 DDS tools was determined by diagnostic accuracy ranking, ease of use and the confidence and

  18. The size of the thymus: an important immunological diagnostic tool?

    DEFF Research Database (Denmark)

    Jeppesen, Dorthe Lisbeth

    2003-01-01

    of the thymus relevant to its function and could measurement of the thymus be a useful immunological diagnostic tool in the investigation of thymic function in humans with a depressed immune system? Conclusion: Studies using the size of the thymus as an immunological diagnostic tool should be encouraged....

  19. Determination of diagnostic standards on saturated soil extracts for cut roses grown in greenhouses.

    Science.gov (United States)

    Franco-Hermida, John Jairo; Quintero, María Fernanda; Cabrera, Raúl Iskander; Guzman, José Miguel

    2017-01-01

    This work comprises the theoretical determination and validation of diagnostic standards for the analysis of saturated soil extracts for cut rose flower crops (Rosa spp.) growing in the Bogota Plateau, Colombia. The data included 684 plant tissue analyses and 684 corresponding analyses of saturated soil extracts, all collected between January 2009 and June 2013. The tissue and soil samples were selected from 13 rose farms, and from cultivars grafted on the 'Natal Briar' rootstock. These concurrent samples of soil and plant tissues represented 251 production units (locations) of approximately 10,000 m2 distributed across the study area. The standards were conceived as a tool to improve the nutritional balance in the leaf tissue of rose plants and thereby define the norms for expressing optimum productive potential relative to nutritional conditions in the soil. To this end, previously determined diagnostic standard for rose leaf tissues were employed to obtain rates of foliar nutritional balance at each analyzed location and as criteria for determining the diagnostic norms for saturated soil extracts. Implementing this methodology to foliar analysis, showed a higher significant correlation for diagnostic indices. A similar behavior was observed in saturated soil extracts analysis, becoming a powerful tool for integrated nutritional diagnosis. Leaf analyses determine the most limiting nutrients for high yield and analyses of saturated soil extracts facilitate the possibility of correcting the fertigation formulations applied to soils or substrates. Recommendations are proposed to improve the balance in soil-plant system with which the possibility of yield increase becomes more probable. The main recommendations to increase and improve rose crop flower yields would be: continuously check pH values of SSE, reduce the amounts of P, Fe, Zn and Cu in fertigation solutions and carefully analyze the situation of Mn in the soil-plant system.

  20. Comparison of novel and standard diagnostic tools for the detection of Schistosoma mekongi infection in Lao People's Democratic Republic and Cambodia.

    Science.gov (United States)

    Vonghachack, Youthanavanh; Sayasone, Somphou; Khieu, Virak; Bergquist, Robert; van Dam, Govert J; Hoekstra, Pytsje T; Corstjens, Paul L A M; Nickel, Beatrice; Marti, Hanspeter; Utzinger, Jürg; Muth, Sinuon; Odermatt, Peter

    2017-08-10

    Given the restricted distribution of Schistosoma mekongi in one province in Lao People's Democratic Republic (Lao PDR) and two provinces in Cambodia, together with progress of the national control programmes aimed at reducing morbidity and infection prevalence, the elimination of schistosomiasis mekongi seems feasible. However, sensitive diagnostic tools will be required to determine whether elimination has been achieved. We compared several standard and novel diagnostic tools in S. mekongi-endemic areas. The prevalence and infection intensity of S. mekongi were evaluated in 377 study participants from four villages in the endemic areas in Lao PDR and Cambodia using Kato-Katz stool examination, antibody detection based on an enzyme-linked immunosorbent assay (ELISA) and schistosome circulating antigen detection by lateral-flow tests. Two highly sensitive test systems for the detection of cathodic and anodic circulating antigens (CCA, CAA) in urine and serum were utilized. Stool microscopy revealed an overall prevalence of S. mekongi of 6.4% (one case in Cambodia and 23 cases in Lao PDR), while that of Opisthorchis viverrini, hookworm, Trichuris trichiura, Ascaris lumbricoides and Taenia spp. were 50.4%, 28.1%, 3.5%, 0.3% and 1.9%, respectively. In the urine samples, the tests for CCA and CAA detected S. mekongi infections in 21.0% and 38.7% of the study participants, respectively. In the serum samples, the CAA assay revealed a prevalence of 32.4%, while a combination of the CAA assay in serum and in urine revealed a prevalence of 43.2%. There was a difference between the two study locations with a higher prevalence reached in the samples from Lao PDR. The CCA, CAA and ELISA results showed substantially higher prevalence estimates for S. mekongi compared to Kato-Katz thick smears. Active schistosomiasis mekongi in Lao PDR and Cambodia might thus have been considerably underestimated previously. Hence, sustained control efforts are still needed to break transmission

  1. Upgrading the Medical Physics Calibration Laboratory Towards ISO/IEC 17025: Radiation Standards and Calibration in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Muhammad Jamal Md Isa; Abd Aziz Mhd Ramli; Wan Hazlinda Ismail; Norhayati Abdullah; Shahrul Azlan Azizan; Siti Sara Deraman; Nor Azlin Azraai; Md Khairusalih Md Zin

    2010-01-01

    Calibration of quality control (QC) test tools used in diagnostic radiology is legally required under the Ministry of Health (MOH) requirement. The Medical Physics Calibration Laboratory of the Malaysian Nuclear Agency is the national focal point for the calibration of quality control test tools used in diagnostic radiology. The Medical Physics Calibration Laboratory has measurement traceability to primary standard dosimetry laboratory (Physikalisch-Technische Bundesanstalt (PTB)), thus providing an interface between the primary standard dosimetry laboratory and Malaysian hospitals, clinics and license class H holder. The Medical Physics Calibration Laboratory facility is comprised of a constant potential x-ray system with a capability of 160 kV tube and a series of reference and working standard ion chambers. The stability of reference and working standard ion chambers was measured using strontium-90. Dosimetric instruments used in diagnostic radiology is calibrated in terms of air kerma to comply with an International Code of Practices of dosimetry for example IAEA's Technical Report Series number 457. The new series of standard radiation qualities was established based on ISO/IEC 61267. The measurement of beam homogeneity was measured using film and ion chamber to define the field size at certain distance and kV output was measured using the spectrometer and non-invasive kVp meter. The uncertainties measurement was determined with expended uncertainties to a level of confidence of approximately 95% (coverage factor k=2). This paper describes the available facility and the effort of the Medical Physics Calibration Laboratory to upgrade the laboratory towards ISO/IEC 17025. (author)

  2. Measurement properties of screening and diagnostic tools for autism spectrum adults of mean normal intelligence: A systematic review.

    Science.gov (United States)

    Baghdadli, A; Russet, F; Mottron, L

    2017-07-01

    The autism spectrum (AS) is a multifaceted neurodevelopmental variant associated with lifelong challenges. Despite the relevant importance of identifying AS in adults for epidemiological, public health, and quality of life issues, the measurement properties of the tools currently used to screen and diagnose adults without intellectual disabilities (ID) have not been assessed. This systematic review addresses the accuracy, reliability, and validity of the reported AS screening and diagnostic tools used in adults without ID. Electronic databases and bibliographies were searched, and identified papers evaluated against inclusion criteria. The PRISMA statement was used for reporting the review. We evaluated the quality of the papers using the COSMIN Checklist for psychometric data, and QUADAS-2 for diagnostic data. For the COSMIN assessment, evidence was considered to be strong when several methodologically good articles, or one excellent article, reported consistent evidence for or against a measurement property. For the QUADAS ratings, evidence was considered to be "satisfactory" if at least one study was rated with a low risk of bias and low concern about applicability. We included 38 articles comprising 32 studies, five reviews, and one book chapter and assessed nine tools (three diagnostic and six screening, including eight of their short versions). Among screening tools, only AQ-50, AQ-S, and RAADS-R and RAADS-14 were found to provide satisfactory or intermediate values for their psychometric properties, supported by strong or moderate evidence. Nevertheless, risks of bias and concerns on the applicability of these tools limit the evidence on their diagnostic properties. We found that none of the gold standard diagnostic tools used for children had satisfactory measurement properties. There is limited evidence for the measurement properties of the screening and diagnostic tools used for AS adults with a mean normal range of measured intelligence. This may lessen

  3. Diagnostic accuracy research in glaucoma is still incompletely reported: An application of Standards for Reporting of Diagnostic Accuracy Studies (STARD 2015.

    Directory of Open Access Journals (Sweden)

    Manuele Michelessi

    Full Text Available Research has shown a modest adherence of diagnostic test accuracy (DTA studies in glaucoma to the Standards for Reporting of Diagnostic Accuracy Studies (STARD. We have applied the updated 30-item STARD 2015 checklist to a set of studies included in a Cochrane DTA systematic review of imaging tools for diagnosing manifest glaucoma.Three pairs of reviewers, including one senior reviewer who assessed all studies, independently checked the adherence of each study to STARD 2015. Adherence was analyzed on an individual-item basis. Logistic regression was used to evaluate the effect of publication year and impact factor on adherence.We included 106 DTA studies, published between 2003-2014 in journals with a median impact factor of 2.6. Overall adherence was 54.1% for 3,286 individual rating across 31 items, with a mean of 16.8 (SD: 3.1; range 8-23 items per study. Large variability in adherence to reporting standards was detected across individual STARD 2015 items, ranging from 0 to 100%. Nine items (1: identification as diagnostic accuracy study in title/abstract; 6: eligibility criteria; 10: index test (a and reference standard (b definition; 12: cut-off definitions for index test (a and reference standard (b; 14: estimation of diagnostic accuracy measures; 21a: severity spectrum of diseased; 23: cross-tabulation of the index and reference standard results were adequately reported in more than 90% of the studies. Conversely, 10 items (3: scientific and clinical background of the index test; 11: rationale for the reference standard; 13b: blinding of index test results; 17: analyses of variability; 18; sample size calculation; 19: study flow diagram; 20: baseline characteristics of participants; 28: registration number and registry; 29: availability of study protocol; 30: sources of funding were adequately reported in less than 30% of the studies. Only four items showed a statistically significant improvement over time: missing data (16, baseline

  4. Clinical history in management of suspected syncope: A powerful diagnostic tool

    NARCIS (Netherlands)

    Sutton, Richard; van Dijk, Nynke; Wieling, Wouter

    2014-01-01

    In this paper, the role of history taking as a diagnostic tool in patients with transient loss of consciousness (TLOC) is addressed. From a literature review it can be demonstrated that, if properly performed, the history is a powerful diagnostic tool, which in the majority of cases proves to be the

  5. Is this the right normalization? A diagnostic tool for ChIP-seq normalization.

    Science.gov (United States)

    Angelini, Claudia; Heller, Ruth; Volkinshtein, Rita; Yekutieli, Daniel

    2015-05-09

    Chip-seq experiments are becoming a standard approach for genome-wide profiling protein-DNA interactions, such as detecting transcription factor binding sites, histone modification marks and RNA Polymerase II occupancy. However, when comparing a ChIP sample versus a control sample, such as Input DNA, normalization procedures have to be applied in order to remove experimental source of biases. Despite the substantial impact that the choice of the normalization method can have on the results of a ChIP-seq data analysis, their assessment is not fully explored in the literature. In particular, there are no diagnostic tools that show whether the applied normalization is indeed appropriate for the data being analyzed. In this work we propose a novel diagnostic tool to examine the appropriateness of the estimated normalization procedure. By plotting the empirical densities of log relative risks in bins of equal read count, along with the estimated normalization constant, after logarithmic transformation, the researcher is able to assess the appropriateness of the estimated normalization constant. We use the diagnostic plot to evaluate the appropriateness of the estimates obtained by CisGenome, NCIS and CCAT on several real data examples. Moreover, we show the impact that the choice of the normalization constant can have on standard tools for peak calling such as MACS or SICER. Finally, we propose a novel procedure for controlling the FDR using sample swapping. This procedure makes use of the estimated normalization constant in order to gain power over the naive choice of constant (used in MACS and SICER), which is the ratio of the total number of reads in the ChIP and Input samples. Linear normalization approaches aim to estimate a scale factor, r, to adjust for different sequencing depths when comparing ChIP versus Input samples. The estimated scaling factor can easily be incorporated in many peak caller algorithms to improve the accuracy of the peak identification. The

  6. [Diagnostic tools for canine parvovirus infection].

    Science.gov (United States)

    Proksch, A L; Hartmann, K

    2015-01-01

    Canine parvovirus (CPV) infection is one of the most important and common infectious diseases in dogs, in particular affecting young puppies when maternal antibodies have waned and vaccine-induced antibodies have not yet developed. The mortality rate remains high. Therefore, a rapid and safe diagnostic tool is essential to diagnose the disease to 1) provide intensive care treatment and 2) to identify virus-shedding animals and thus prevent virus spread. Whilst the detection of antibodies against CPV is considered unsuitable to diagnose the disease, there are several different methods to directly detect complete virus, virus antigen or DNA. Additionally, to test in commercial laboratories, rapid in-house tests based on ELISA are available worldwide. The specificity of the ELISA rapid in-house tests is reported to be excellent. However, results on sensitivity vary and high numbers of false-negative results are commonly reported, which potentially leads to misdiagnosis. Polymerase chain reaction (PCR) is a very sensitive and specific diagnostic tool. It also provides the opportunity to differentiate vaccine strains from natural infection when sequencing is performed after PCR.

  7. Diagnosis demystified: CT as diagnostic tool in endodontics

    Science.gov (United States)

    Shruthi, Nagaraja; Sreenivasa Murthy, B V; Sundaresh, K J; Mallikarjuna, Rachappa

    2013-01-01

    Diagnosis in endodontics is usually based on clinical and radiographical presentations, which are only empirical methods. The role of healing profession is to apply knowledge and skills towards maintaining and restoring the patient's health. Recent advances in imaging technologies have added to correct interpretation and diagnosis. CT is proving to be an effective tool in solving endodontic mysteries through its three-dimensional visualisation. CT imaging offers many diagnostic advantages to produce reconstructed images in selected projection and low-contrast resolution far superior to that of all other X-ray imaging modalities. This case report is an endeavour towards effective treatment planning of cases with root fracture, root resorption using spiral CT as an adjuvant diagnostic tool. PMID:23814212

  8. Diagnostic framework and health check tool for engineering and technology projects

    Directory of Open Access Journals (Sweden)

    Simon P Philbin

    2014-10-01

    Full Text Available Purpose: Development of a practitioner oriented diagnostic framework and health check tool to support the robust assessment of engineering and technology projects.Design/methodology/approach: The research is based on a literature review that draws together insights on project assessment and critical success factors to establish an integrated systems view of projects. This is extended to allow a comprehensive diagnostic framework to be developed along with a high-level health check tool that can be readily deployed on projects. The utility of the diagnostic framework and health check tool are explored through three illustrative case studies, with two from Canada and one from the United Kingdom. Findings andOriginality/value: The performance of engineering and technology projects can be viewed through a systems perspective and being a function of six sub-systems that are: process, technology, resources, impact, knowledge and culture. The diagnostic framework that is developed through this research integrates these sub-systems to provide a comprehensive assessment methodology for projects, which is linked to existing best practice for project reviews, performance management and maturity models. The case studies provide managerial insights that are related to the diagnostic framework but crucially also position the approach in the context of industrial applications for construction engineering and technology management.Research limitations/implications: The case study approach includes two case studies from the construction and facilities development sector with the third case study from the research and technology sector. Further work is required to investigate the use of the diagnostic framework and health check tool in other sectors.Practical implications: The health check tool will be of practical benefit to new projects managers that require access to a robust and convenient project review methodology for assessing the status and health of a

  9. The diagnostic and prognostic value of conventional and rapid diagnostic tools in malaria

    OpenAIRE

    Chandrakanth C.H

    2016-01-01

    Background: The burden of malaria is raising all over the world and India is no exception. Despite well established treatment regimens and diagnostic tools, Malaria is thought to kill between1.1 to 2.7 million people worldwide each year. Rapid diagnosis and early treatment are one of the key factors in controlling the disease burden of malaria. Objective: The study was conducted to investigate the diagnostic and prognostic utility of rapid test (QBC, PLDH, HRP2) with conventional thick and th...

  10. Development of a High-Temperature Diagnostics-While-Drilling Tool

    Energy Technology Data Exchange (ETDEWEB)

    Blankenship, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Chavira, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Henfling, Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hetmaniak, Chris [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Huey, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jacobson, Ron [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); King, Dennis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Knudsen, Steve [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mansure, A. J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Polsky, Yarom [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2009-01-01

    This report documents work performed in the second phase of the Diagnostics While-Drilling (DWD) project in which a high-temperature (HT) version of the phase 1 low-temperature (LT) proof-of-concept (POC) DWD tool was built and tested. Descriptions of the design, fabrication and field testing of the HT tool are provided.

  11. Prostate cancer diagnostics: Clinical challenges and the ongoing need for disruptive and effective diagnostic tools.

    Science.gov (United States)

    Sharma, Shikha; Zapatero-Rodríguez, Julia; O'Kennedy, Richard

    The increased incidence and the significant health burden associated with carcinoma of the prostate have led to substantial changes in its diagnosis over the past century. Despite technological advancements, the management of prostate cancer has become progressively more complex and controversial for both early and late-stage disease. The limitations and potential harms associated with the use of prostate-specific antigen (PSA) as a diagnostic marker have stimulated significant investigation of numerous novel biomarkers that demonstrate varying capacities to detect prostate cancer and can decrease unnecessary biopsies. However, only a few of these markers have been approved for specific clinical settings while the others have not been adequately validated for use. This review systematically and critically assesses ongoing issues and emerging challenges in the current state of prostate cancer diagnostic tools and the need for disruptive next generation tools based on analysis of combinations of these biomarkers to enhance predictive accuracy which will benefit clinical diagnostics and patient welfare. Copyright © 2016. Published by Elsevier Inc.

  12. The Shoulder Objective Practical Assessment Tool: Evaluation of a New Tool Assessing Residents Learning in Diagnostic Shoulder Arthroscopy.

    Science.gov (United States)

    Talbot, Christopher L; Holt, Edward M; Gooding, Benjamin W T; Tennent, Thomas D; Foden, Philip

    2015-08-01

    To design and validate an objective practical assessment tool for diagnostic shoulder arthroscopy that would provide residents with a method to evaluate their progression in this field of surgery and to identify specific learning needs. We designed and evaluated the shoulder Objective Practical Assessment Tool (OPAT). The shoulder OPAT was designed by us, and scoring domains were created using a Delphi process. The shoulder OPAT was trialed by members of the British Elbow & Shoulder Society Education Committee for internal consistency and ease of use before being offered to other trainers and residents. Inter-rater reliability and intrarater reliability were calculated. One hundred forty orthopaedic residents, of varying seniority, within 5 training regions in the United Kingdom, were questioned regarding the tool. A pilot study of 6 residents was undertaken. Internal consistency was 0.77 (standardized Cronbach α). Inter-rater reliability was 0.60, and intrarater reliability was 0.82. The Spearman correlation coefficient (r) between the global summary score for the shoulder OPAT and the current assessment tool used in postgraduate training for orthopaedic residents undertaking diagnostic shoulder arthroscopy equaled 0.74. Of the residents, 82% agreed or strongly agreed when asked if the shoulder OPAT would be a useful tool in monitoring progression and 72% agreed or strongly agreed with the introduction of the shoulder OPAT within the orthopaedic domain. This study shows that the shoulder OPAT fulfills several aspects of reliability and validity when tested. Despite the inter-rater reliability being 0.60, we believe that the shoulder OPAT has the potential to play a role alongside the current assessment tool in the training of orthopaedic residents. The shoulder OPAT can be used to assess residents during shoulder arthroscopy and has the potential for use in medical education, as well as arthroscopic skills training in the operating theater. Copyright © 2015

  13. Review of diagnostic tools to investigate the physical state of rapid granular filters

    DEFF Research Database (Denmark)

    Lopato, Laure Rose; Binning, Philip John; Arvin, Erik

    2012-01-01

    This paper reviews diagnostic tools that can be used at waterworks to investigate the physical and operational state of rapid granular filters. Diagnostic tools can be of interest for the Water Safety Plans of WHO to monitor filters in a proactive manner. The review considers conventional and state...

  14. Computing tools for implementing standards for single-case designs.

    Science.gov (United States)

    Chen, Li-Ting; Peng, Chao-Ying Joanne; Chen, Ming-E

    2015-11-01

    In the single-case design (SCD) literature, five sets of standards have been formulated and distinguished: design standards, assessment standards, analysis standards, reporting standards, and research synthesis standards. This article reviews computing tools that can assist researchers and practitioners in meeting the analysis standards recommended by the What Works Clearinghouse: Procedures and Standards Handbook-the WWC standards. These tools consist of specialized web-based calculators or downloadable software for SCD data, and algorithms or programs written in Excel, SAS procedures, SPSS commands/Macros, or the R programming language. We aligned these tools with the WWC standards and evaluated them for accuracy and treatment of missing data, using two published data sets. All tools were tested to be accurate. When missing data were present, most tools either gave an error message or conducted analysis based on the available data. Only one program used a single imputation method. This article concludes with suggestions for an inclusive computing tool or environment, additional research on the treatment of missing data, and reasonable and flexible interpretations of the WWC standards. © The Author(s) 2015.

  15. Performance Assessment as a Diagnostic Tool for Science Teachers

    Science.gov (United States)

    Kruit, Patricia; Oostdam, Ron; van den Berg, Ed; Schuitema, Jaap

    2018-04-01

    Information on students' development of science skills is essential for teachers to evaluate and improve their own education, as well as to provide adequate support and feedback to the learning process of individual students. The present study explores and discusses the use of performance assessments as a diagnostic tool for formative assessment to inform teachers and guide instruction of science skills in primary education. Three performance assessments were administered to more than 400 students in grades 5 and 6 of primary education. Students performed small experiments using real materials while following the different steps of the empirical cycle. The mutual relationship between the three performance assessments is examined to provide evidence for the value of performance assessments as useful tools for formative evaluation. Differences in response patterns are discussed, and the diagnostic value of performance assessments is illustrated with examples of individual student performances. Findings show that the performance assessments were difficult for grades 5 and 6 students but that much individual variation exists regarding the different steps of the empirical cycle. Evaluation of scores as well as a more substantive analysis of students' responses provided insight into typical errors that students make. It is concluded that performance assessments can be used as a diagnostic tool for monitoring students' skill performance as well as to support teachers in evaluating and improving their science lessons.

  16. Transcranial brainstem sonography as a diagnostic tool for amyotrophic lateral sclerosis.

    Science.gov (United States)

    Prell, Tino; Schenk, Annekathrin; Witte, Otto W; Grosskreutz, Julian; Günther, Albrecht

    2014-06-01

    Diagnosing amyotrophic lateral sclerosis (ALS) can be difficult, particularly in the early stage of disease; therefore, we evaluated the use of transcranial stem sonography (TCS) to improve early detection of the disease. In this cross-sectional study, 94 patients with sporadic ALS and 46 age- and gender-matched healthy controls were evaluated by TCS according to a standardized protocol used to diagnose Parkinson's disease. Approximately half (48%) of the patients with ALS showed a clear (> 0.25 cm(2)) mesencephalic hyperechogenic structure, 20% showed a possible (laterally. In conclusion, although the neuropathological correlation to hyperechogenicity remains unclear, TCS is an easy, feasible and reproducible technique that could serve as an additional diagnostic tool and as a surrogate biomarker in ALS.

  17. Air kerma standardization for diagnostic radiology in a secondary standard laboratory

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Lopes, Ricardo T.

    2009-01-01

    The demand for calibration services and quality control in diagnostic radiology has grown in the country since the publication of the governmental regulation 453, issued by the Brazilian Ministry of Health in 1998. At that time, to produce results facing the new legislation, many laboratories used different standards and radiation qualities, some of which could be inadequate. The international standards neither supplied consistent radiation qualities and standardization for the different types of equipment available. This situation changed with the publication of the new edition of the IEC 61267 standard, published in 2005. The objective of this work was to implement the standardization of the air kerma for the unatenuated qualities (RQR) of IEC 61267 in the National Laboratory of Metrology of the Ionizing Radiations (LNMRI) of the Institute of Radiation Protection and Dosimetry (IRD). Technical procedures were developed together with uncertainty budget. Results of interlaboratory comparisons demonstrate that the quantity is standardized and internationally traceable. (author)

  18. Does Radar Technology Support the Diagnosis of Pneumothorax? PneumoScan—A Diagnostic Point-of-Care Tool

    Directory of Open Access Journals (Sweden)

    T. Lindner

    2013-01-01

    Full Text Available Background. A nonrecognized pneumothorax (PTX may become a life-threatening tension PTX. A reliable point-of-care diagnostic tool could help in reduce this risk. For this purpose, we investigated the feasibility of the use of the PneumoScan, an innovative device based on micropower impulse radar (MIR. Patients and Methods. addition to a standard diagnostic protocol including clinical examination, chest X-ray (CXR, and computed tomography (CT, 24 consecutive patients with chest trauma underwent PneumoScan testing in the shock trauma room to exclude a PTX. Results. The application of the PneumoScan was simple, quick, and reliable without functional disorder. Clinical examination and CXR each revealed one and PneumoScan three out of altogether four PTXs (sensitivity 75%, specificity 100%, positive predictive value 100%, and negative predictive value 95%. The undetected PTX did not require intervention. Conclusion. The PneumoScan as a point-of-care device offers additional diagnostic value in patient management following chest trauma. Further studies with more patients have to be performed to evaluate the diagnostic accuracy of the device.

  19. Celiac Disease: Diagnostic Standards and Dilemmas

    Science.gov (United States)

    Kaswala, Dharmesh H.; Veeraraghavan, Gopal; Kelly, Ciaran P.; Leffler, Daniel A.

    2015-01-01

    Celiac Disease (CD) affects at least 1% of the population and evidence suggests that prevalence is increasing. The diagnosis of CD depends on providers being alert to both typical and atypical presentations and those situations in which patients are at high risk for the disease. Because of variable presentation, physicians need to have a low threshold for celiac testing. Robust knowledge of the pathogenesis of this autoimmune disease has served as a catalyst for the development of novel diagnostic tools. Highly sensitive and specific serological assays including Endomysial Antibody (EMA), tissue transglutaminase (tTG), and Deamidated Gliadin Peptide (DGP) have greatly simplified testing for CD and serve as the foundation for celiac diagnosis. In addition, genetic testing for HLA DQ2 and DQ8 has become more widely available and there has been refinement of the gluten challenge for use in diagnostic algorithms. While diagnosis is usually straightforward, in special conditions including IgA deficiency, very young children, discrepant histology and serology, and adoption of a gluten free diet prior to testing, CD can be difficult to diagnose. In this review, we provide an overview of the history and current state of celiac disease diagnosis and provide guidance for evaluation of CD in difficult diagnostic circumstances. PMID:28943611

  20. Addiction screening and diagnostic tools: 'Refuting' and 'unmasking' claims to legitimacy.

    Science.gov (United States)

    Dwyer, Robyn; Fraser, Suzanne

    2015-12-01

    Human practices of all kinds - substance use, gambling, sex, even eating - are increasingly being reframed through the language of addiction. This 'addicting' of contemporary society is achieved, in part, through the screening and diagnostic tools intended to identify and measure addiction. These tools are a key element in the expert knowledge-making through which realities of addiction emerge. Promoted as objective and accurate, the tools are given legitimacy through application of scientific validation techniques. In this article, we critically examine the operations of these validation techniques as applied to substance addiction tools. Framed by feminist and other scholarship that decentres the epistemological guarantees of objectivity and validity, we structure our analysis using Ian Hacking's (1999) concepts of 'refuting' (showing a thesis to be false) and 'unmasking' (undermining a thesis). Under 'refuting', we consider the methodological validation processes on their own terms, identifying contradictory claims, weak findings and inconsistent application of methodological standards. Under 'unmasking', we critically analyse validation as a concept in itself. Here we identify two fundamental problems: symptom learning and feedback effects; and circularity and assumptions of independence and objectivity. Our analysis also highlights the extra-theoretical functions and effects of the tools. Both on their own terms and when subjected to more searching analysis, then, the validity claims the tools make fail to hold up to scrutiny. In concluding, we consider some of the effects of the processes we identify. Not only do these tools make certainty where there is none, we contend, they actively participate in the creation of social objects and social groups, and in shaping affected individuals and their opportunities. In unpacking in detail the legitimacy of the tools, our aim is to open up for further scrutiny the processes by which they go about making (rather than

  1. Organization and standards of screening and diagnostic mammography

    International Nuclear Information System (INIS)

    Linderbraten, L.D.; Chikirdin, Eh.G.; Rozhkova, N.I.

    1999-01-01

    Problem of organizing and standards of the reference and diagnostic mammography in our country is discussed. Attention is paid to the terminology, accreditation of mammographic establishments and specialists, specifications of equipment, image quality, mammography results processing, radiation doses [ru

  2. A New Paradigm for Tissue Diagnostics: Tools and Techniques to Standardize Tissue Collection, Transport, and Fixation.

    Science.gov (United States)

    Bauer, Daniel R; Otter, Michael; Chafin, David R

    2018-01-01

    Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions. This review examines the area of tissue collection, transport, and monitoring of formalin diffusion and details a prototype system that could be used to help standardize tissue collection efforts. We have surveyed recent primary literature sources and conducted several site visits to understand the most error-prone processes in histology laboratories. This effort identified errors that resulted from sample collection techniques and subsequent transport delays from the operating room (OR) to the histology laboratories. We have therefore devised a prototype sample collection and transport concept. The system consists of a custom data logger and cold transport box and takes advantage of a novel cold + warm (named 2 + 2) fixation method. This review highlights the beneficial aspects of standardizing tissue collection, fixation, and monitoring. In addition, a prototype system is introduced that could help standardize these processes and is compatible with use directly in the OR and from remote sites.

  3. A construction of standardized near infrared hyper-spectral teeth database: a first step in the development of reliable diagnostic tool for quantification and early detection of caries

    Science.gov (United States)

    Bürmen, Miran; Usenik, Peter; Fidler, Aleš; Pernuš, Franjo; Likar, Boštjan

    2011-03-01

    Dental caries is a disease characterized by demineralization of enamel crystals leading to the penetration of bacteria into the dentin and pulp. If left untreated, the disease can lead to pain, infection and tooth loss. Early detection of enamel demineralization resulting in increased enamel porosity, commonly known as white spots, is a difficult diagnostic task. Several papers reported on near infrared (NIR) spectroscopy to be a potentially useful noninvasive spectroscopic technique for early detection of caries lesions. However, the conducted studies were mostly qualitative and did not include the critical assessment of the spectral variability of the sound and carious dental tissues and influence of the water content. Such assessment is essential for development and validation of reliable qualitative and especially quantitative diagnostic tools based on NIR spectroscopy. In order to characterize the described spectral variability, a standardized diffuse reflectance hyper-spectral database was constructed by imaging 12 extracted human teeth with natural lesions of various degrees in the spectral range from 900 to 1700 nm with spectral resolution of 10 nm. Additionally, all the teeth were imaged by digital color camera. The influence of water content on the acquired spectra was characterized by monitoring the teeth during the drying process. The images were assessed by an expert, thereby obtaining the gold standard. By analyzing the acquired spectra we were able to accurately model the spectral variability of the sound dental tissues and identify the advantages and limitations of NIR hyper-spectral imaging.

  4. Pharmaceutical care and the use of routine diagnostic tools by ...

    African Journals Online (AJOL)

    Purpose: To evaluate the use of routine diagnostic tools among community pharmacists in Ibadan,. Nigeria. ... measurement, and tests for serum cholesterol, capillary .... Development .... Duweijua M, Dodoo A, Plange R. Quality Counseling on.

  5. Improvement of Diagnostic Accuracy by Standardization in Diuretic Renal Scan

    International Nuclear Information System (INIS)

    Hyun, In Young; Lee, Dong Soo; Lee, Kyung Han; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Kim, Kwang Myung; Choi, Hwang; Choi, Yong

    1995-01-01

    We evaluated diagnostic accuracy of diuretic renal scan with standardization in 45 children(107 hydronephrotic kidneys) with 91 diuretic assessments. Sensitivity was 100% specificity was 78%, and accuracy was 84% in 49 hydronephrotic kidneys with standardization. Diuretic renal scan without standardization, sensitivity was 100%, specificity was 38%, and accuracy was 57% in 58 hydronephrotic kidneys. The false-positive results were observed in 25 cases without standardization, and in 8 cases with standardization. In duretic renal scans without standardization, the causes of false-positive results were 10 early injection of lasix before mixing of radioactivity in loplsty, 6 extrarenal pelvis, and 3 immature kidneys of false-positive results were 2 markedly dilated systems postpyeloplsty, 2 etrarenal pevis, 1 immature kidney of neonate , and 2 severe renal dysfunction, 1 vesicoureteral, reflux. In diuretic renal scan without standardization the false-positive results by inadequate study were common, but false-positive results by inadequate study were not found after standardization. The false-positive results by dilated pelvo-calyceal systems postpyeloplsty, extrarenal pelvis, and immature kidneys of, neonates were not dissolved after standardization. In conclusion, diagnostic accuracy of diuretic renal scan with standardization was useful in children with renal outflow tract obstruction by improving specificity significantly.

  6. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    OpenAIRE

    A. Yu. Galkin; A. G. Komar; A. A. Grigorenko

    2015-01-01

    In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO...

  7. Problem Representation, Background Evidence, Analysis, Recommendation: An Oral Case Presentation Tool to Promote Diagnostic Reasoning.

    Science.gov (United States)

    Carter, Cristina; Akar-Ghibril, Nicole; Sestokas, Jeff; Dixon, Gabrina; Bradford, Wilhelmina; Ottolini, Mary

    2018-03-01

    Oral case presentations provide an opportunity for trainees to communicate diagnostic reasoning at the bedside. However, few tools exist to enable faculty to provide effective feedback. We developed a tool to assess diagnostic reasoning and communication during oral case presentations. Published by Elsevier Inc.

  8. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  9. Prototype of a diagnostic decision support tool for structural damage in masonry

    NARCIS (Netherlands)

    De Vent, I.A.E.

    2011-01-01

    This prototype of a diagnostic decision support tool for structural damage in traditional masonry is the result of a PhD research project. The research project has aimed to improve and facilitate the diagnostic process by offering support in the initial phase in which hypotheses are generated. The

  10. National radiology standards in X-ray diagnostic incl. interventional radiology

    International Nuclear Information System (INIS)

    Valek, V.; Kratochvil, P.

    2005-01-01

    In 2004 the Ministry of Health care started within the frame of the program for support of quality in health care a project consisting of 4 separate tasks: creating of standards for medical irradiation in radiodiagnostics, in radiotherapy , in nuclear medicine and creating of standards for patients dose assessment in radiophysics. This document continues with description of a part of the project aimed on X-ray radiodiagnostics. The authors of the project were chosen based on their bids to the public grant issued by the Ministry of Health care. The authors used recommendations, guidelines and instructions of international professional societies and IAEA, as well as the already existing procedures and practices while considering possibilities and state of the praxis in the Czech Republic. The outcome of authors work is now an interim version of a document that will be published in the bulletin of the Ministry of Health care. The document contains a set of standards that cover the whole range o fall complimentarily performed ways of patients irradiation in X-ray diagnostics and interventional radiology . The standards are divided to several categories according to the requirement of the Ministry of Health care based on the diagnostic appliances used for diagnostic irradiation i.e. radiography , fluoroscopy, mammography, stomatology, computer tomography, angiography, interventional radiography and cardiography. (authors)

  11. Virtual standards of vibration-based defects diagnostics in railway industry

    Directory of Open Access Journals (Sweden)

    Vladimir TETTER

    2009-01-01

    Full Text Available The issues related to testing the functionality stated by producers of vibration-based diagnostic equipment have been considered. The introduction of virtual standards of defects found in bearing and geared assemblies of rolling stock is offered. The variants of virtual standards realization have been considered.

  12. A defect-driven diagnostic method for machine tool spindles.

    Science.gov (United States)

    Vogl, Gregory W; Donmez, M Alkan

    2015-01-01

    Simple vibration-based metrics are, in many cases, insufficient to diagnose machine tool spindle condition. These metrics couple defect-based motion with spindle dynamics; diagnostics should be defect-driven. A new method and spindle condition estimation device (SCED) were developed to acquire data and to separate system dynamics from defect geometry. Based on this method, a spindle condition metric relying only on defect geometry is proposed. Application of the SCED on various milling and turning spindles shows that the new approach is robust for diagnosing the machine tool spindle condition.

  13. Cancer-associated fibroblasts as target and tool in cancer therapeutics and diagnostics.

    Science.gov (United States)

    De Vlieghere, Elly; Verset, Laurine; Demetter, Pieter; Bracke, Marc; De Wever, Olivier

    2015-10-01

    Cancer-associated fibroblasts (CAFs) are drivers of tumour progression and are considered as a target and a tool in cancer diagnostic and therapeutic applications. An increased abundance of CAFs or CAF signatures are recognized as a bad prognostic marker in several cancer types. Tumour-environment biomimetics strongly improve our understanding of the communication between CAFs, cancer cells and other host cells. Several experimental drugs targeting CAFs are in clinical trials for multiple tumour entities; alternatively, CAFs can be exploited as a tool to characterize the functionality of circulating tumour cells or to capture them as a tool to prevent metastasis. The continuous interaction between tissue engineers, biomaterial experts and cancer researchers creates the possibility to biomimic the tumour-environment and provides new opportunities in cancer diagnostics and management.

  14. The IDEA Assessment Tool: Assessing the Reporting, Diagnostic Reasoning, and Decision-Making Skills Demonstrated in Medical Students' Hospital Admission Notes.

    Science.gov (United States)

    Baker, Elizabeth A; Ledford, Cynthia H; Fogg, Louis; Way, David P; Park, Yoon Soo

    2015-01-01

    Construct: Clinical skills are used in the care of patients, including reporting, diagnostic reasoning, and decision-making skills. Written comprehensive new patient admission notes (H&Ps) are a ubiquitous part of student education but are underutilized in the assessment of clinical skills. The interpretive summary, differential diagnosis, explanation of reasoning, and alternatives (IDEA) assessment tool was developed to assess students' clinical skills using written comprehensive new patient admission notes. The validity evidence for assessment of clinical skills using clinical documentation following authentic patient encounters has not been well documented. Diagnostic justification tools and postencounter notes are described in the literature (1,2) but are based on standardized patient encounters. To our knowledge, the IDEA assessment tool is the first published tool that uses medical students' H&Ps to rate students' clinical skills. The IDEA assessment tool is a 15-item instrument that asks evaluators to rate students' reporting, diagnostic reasoning, and decision-making skills based on medical students' new patient admission notes. This study presents validity evidence in support of the IDEA assessment tool using Messick's unified framework, including content (theoretical framework), response process (interrater reliability), internal structure (factor analysis and internal-consistency reliability), and relationship to other variables. Validity evidence is based on results from four studies conducted between 2010 and 2013. First, the factor analysis (2010, n = 216) yielded a three-factor solution, measuring patient story, IDEA, and completeness, with reliabilities of .79, .88, and .79, respectively. Second, an initial interrater reliability study (2010) involving two raters demonstrated fair to moderate consensus (κ = .21-.56, ρ =.42-.79). Third, a second interrater reliability study (2011) with 22 trained raters also demonstrated fair to moderate agreement

  15. Which children could benefit from additional diagnostic tools in case of suspected appendicitis?

    NARCIS (Netherlands)

    van den Broek, W. T.; van der Ende, E. D.; Bijnen, A. B.; Breslau, P. J.; Gouma, D. J.

    2004-01-01

    Background: New diagnostic tools such as ultrasound scan, computed tomography (CT) scan, and diagnostic laparoscopy, have become available for children with suspected appendicitis but should be reserved for equivocal cases. The aim of this study was to develop a scoring system to identify this

  16. Molecular diagnostics of inflammatory disease: New tools and perspectives.

    Science.gov (United States)

    Garzorz-Stark, Natalie; Lauffer, Felix

    2017-08-01

    This essay reviews current approaches to establish novel molecular diagnostic tools for inflammatory skin diseases. Moreover, it highlights the importance of stratifying patients according to molecular signatures and revising current outdated disease classification systems to eventually reach the goal of personalized medicine. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.

    Science.gov (United States)

    Obuchowski, Nancy A

    2006-02-15

    ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.

  18. Executive summary of European Task Force document on diagnostic tools in rhinology

    NARCIS (Netherlands)

    Hellings, P. W.; Scadding, G.; Alobid, I.; Bachert, C.; Fokkens, W. J.; Gerth van Wijk, R.; Gevaerts, P.; Guilemany, J.; Kalogjera, L.; Lund, V. J.; Mullol, J.; Passalacqua, G.; Toskala, E.; van Drunen, C. M.

    2012-01-01

    This Executive Summary of the EAACI Task Force document on Diagnostic Tools in Rhinology provides the readers with an over- view of the currently available tools for diagnosis of nasal and sino-nasal disease, published in full version in the first issue of Clini- cal and Translational Allergy. A

  19. Diagnosing Chronic Pancreatitis Comparison and Evaluation of Different Diagnostic Tools

    NARCIS (Netherlands)

    Issa, Yama; van Santvoort, Hjalmar C.; van Dieren, Susan; Besselink, Marc G.; Boermeester, Marja A.; Ahmed Ali, Usama

    2017-01-01

    Objectives: This study aims to compare theM-ANNHEIM, Buchler, and Luneburg diagnostic tools for chronic pancreatitis (CP). Methods: A cross-sectional analysis of the development of CP was performed in a prospectively collected multicenter cohort including 669 patients after a first episode of acute

  20. A diagnostic tool on time perception of children with ADHD

    NARCIS (Netherlands)

    Gongsook, P.; Peijnenborgh, J.; Sallustro, C.; Spek, van der E.D.; Hu, J.; Bellotti, F.; Rauterberg, G.W.M.; Hendriksen, J.G.M.; De Gloria, A.

    2014-01-01

    ADHD is among the most common childhood developmental disorder which may affect the school achievements. Children with ADHD may show symptoms of time perception problems. Although ADHD is a clinical diagnosis with several approaches, no diagnostic tool has been designed to detect the symptoms of

  1. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  2. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  3. The diagnostic value of the premature ejaculation diagnostic tool and its association with intravaginal ejaculatory latency time.

    Science.gov (United States)

    Kam, Sung Chul; Han, Deok Hyun; Lee, Sung Won

    2011-03-01

    Premature ejaculation (PE) is the most prevalent male ejaculation disorder. The premature ejaculation diagnostic tool (PEDT) was developed to systematically apply the DSM-IV-TR criteria in diagnostic PE. To evaluate the diagnostic value of the PEDT and its association with intravaginal ejaculatory latency time (IELT). (i) Korean validation of PEDT: data was collected from men interviewed by one of the two clinical experts, who made a diagnostic of present or absence of PE, using DSM-IV-TR criteria. A total of 103 patients with PE and 100 men without PE were enrolled into the study and requested to complete the PEDT; and (ii) The correlation between IELT and PEDT: 200 participants were enrolled and each participant was asked to make out PEDT. All participants were requested to measure IELT. Validity and reliability of the PEDT and its association with IELT. The geometric mean IELT of the PE group was 115.37 ± 78.14 seconds. The number of men reporting IELTs of 2 minutes were 28 (28.6%), 29 (29.6%), and 41 (41.8%), respectively. The Cronbach's alpha score was calculated as 0.93, showing adequate internal consistency. The test-retest correlation coefficients of each item were higher than 0.72 and the correlation coefficients of the total score was 0.88. (P IELT showed an adequate negative correlation. (ρ = -0.77, P IELT ≤ 2 minutes) and IELT showed a negative correlation. (ρ = -0.6, P < 0.0001) The PEDT was highly effective in detecting the presence of PE. The result of our study supports its validity as a diagnostic tool in the clinical setting. © 2010 International Society for Sexual Medicine.

  4. EEG, CT scan and MRI as diagnostic tools for ADHD in population between 6 and 19 years: a systematic review

    Directory of Open Access Journals (Sweden)

    José Calleja

    2012-09-01

    Full Text Available Introduction: Attention deficit and hyperactivity disorder (ADHD is generally diagnosed based on the criteria of DSM-IV. Because several diagnostic tests have appeared such as electroencephalography (EEG, CT scan and magnetic resonance imaging (MRI, there is a particular interest in determining the usefulness and diagnostic accuracy of these tests for the diagnosis of ADHD. Purpose: To identify, synthesize and evaluate the best available evidence on the usefulness of EEG, CT and MRI as a diagnostic tool in ADHD in the 6-19 year-old population. Methods: A systematic review of studies on diagnostic tests that assessed the validity, reliability and effectiveness of the implementation of EEG, CT and MRI in the diagnosis of ADHD in the 6-19 year-old population was conducted. Searches were done in PubMed/MEDLINE, LILACS, Cochrane, DARE and National Guideline Clearinghouse databases, until February 2012, in English and Spanish. The articles that met the inclusion criteria were independently assessed by two investigators for methodological quality using standard checklists for review articles and diagnostic test articles. Results: Of the 115 studies found, eight studies were included, among which two medium-quality systematic reviews and a good-quality primary article on diagnostic tests. Additionally, five evidence-based clinical guidelines that address this issue were also included. Conclusions: The available evidence on the validity, reliability and effectiveness of the electroencephalogram, computed tomography and magnetic resonance imaging, does not recommend their use as diagnostic tools for ADHD. Clinical practice guidelines do not recommend their use either. These tests are recommended for the assessment of the individual patient with the disorder.

  5. A new diagnostic tool for rapid and accurate detection of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    Ali Nour-Neamatollahi

    2018-03-01

    Full Text Available Mycobacterium tuberculosis, acid fast bacilli from the family of Mycobacteriaceae, is the causative agent of most cases of tuberculosis. Tuberculosis, as a communicable disease, remains a serious public health threat, killing more than one million people globally every year. Primary diagnosis of tuberculosis bacilli (TB relies mainly on microscopic detection of acid fast bacilli (AFB, but the method suffers from low sensitivity and the results largely depend on the technician’s skill. New diagnostic tools are necessary to be introduced for rapid and accurate detection of the bacilli in sputum samples. We, in collaboration with Anda Biologicals, have developed a new platform, named as “Patho-tb”, for rapid detection of AFB with high sensitivity and with low dependence on human skills. Evaluation of Patho-tb test performance was done in two settings: (1 primary field study conducted using 38 sputa from high TB prevalence area of Iran (Zabol city near to the Afghanistan border, and (2 main study conducted using 476 sputa from Tehran, capital of Iran. Patho-tb was applied for processed sputum samples in parallel with routine diagnostic methods (including AFB microscopy, culture and PCR. All test results were compared to final clinical diagnostic state of an individual and diagnostic sensitivity (DSe, specificity, positive predictive value, negative predictive value and accuracy of each test results were calculated using standard formulations. Analytical sensitivity and specificity of the Patho-tb test were also determined. Calculated values for five above mentioned parameters are as follows: for field study: AFB (DSe: 29.6, DSp: 81.8, PPV: 80, NPV: 23.1, AC: 44.7, Patho-tb (DSe: 63, DSp: 72.7, PPV: 85, NPV: 44.4, AC: 65.8, and for main study: AFB (DSe: 86.1, DSp: 99.4, PPV: 98.5, NPV: 93.9, AC: 95.2, Patho-tb (DSe: 97.4, DSp: 92.9, PPV: 86.5, NPV: 98.7, AC: 94.3. Reproducibility of Patho-tb test results were near to 100% (Cohen’s kappa value

  6. Plasma water as a diagnostic tool in the assessment of dehydration in children with acute gastroenteritis.

    Science.gov (United States)

    Plaisier, Annemarie; Maingay-de Groof, Femke; Mast-Harwig, Roechama; Kalkman, Patricia M J; Wulkan, Remi W; Verwers, Renee; Neele, Marjolein; Hop, Wim C J; Groeneweg, Michael

    2010-07-01

    Acute gastroenteritis is common in childhood. The estimation of the degree of dehydration is essential for management of acute gastroenteritis. Plasma water was assessed as a diagnostic tool in children with acute gastroenteritis and dehydration admitted to hospital. In a prospective cohort study, 101 patients presenting at the emergency department with dehydration were included. Clinical assessment, routine laboratory tests, and plasma water measurement were performed. Plasma water was measured as a percentage of water content using dry weight method. During admission, patients were rehydrated in 12 h. Weight gain at the end of the rehydration period and 2 weeks thereafter was used to determine the percentage of weight loss as a gold standard for the severity of dehydration. Clinical assessment of dehydration was not significantly associated with the percentage of weight loss. Blood urea nitrogen (r = 0.3, p = 0.03), base excess (r =-0.31, p = 0.03), and serum bicarbonate (r = 0.32, p = 0.02) were significantly correlated with the percentage of weight loss. Plasma water did not correlate with the percentage of weight loss. On the basis of the presented data, plasma water should not be used as a diagnostic tool in the assessment of dehydration in children with acute gastroenteritis.

  7. The Limpopo Non-Metropolitan Drinking Water Supplier Response to a Diagnostic Tool for Technical Compliance.

    Science.gov (United States)

    Nefale, Avhashoni D; Kamika, Ilunga; Obi, Chikwelu L; Momba, Maggy Nb

    2017-07-19

    Water services providers should supply water that is fit for human consumption, taking into account multi-barrier approaches and technical aspects such as design aspects, operation monitoring, final water quality compliance monitoring, plant monitoring practices, maintenance, and risk management practices. Against this background, this study focused on applying the diagnostic tool for technical compliance as well as assessing the compliance of water treatment plants with management norms. Six plants in the Vhembe District Municipality were selected; the Vondo, Malamulele, Mutshedzi, and Mutale plants (conventional), and the Dzingahe and Tshedza package plants. During the first assessment, four (Malamulele, Mutshedzi, Mutale and Dzingahe) plants scored between 44% and 49% and achieved Class 3 certification, revealing serious challenges requiring immediate intervention. Two water plants (Vondo and Tshedza, scoring 53% and 63%, respectively) were in the Class 2 category, revealing serious challenges requiring attention and improvement. During the second assessment, all plants scored between 63% and 87% (Class 2 category). The greatest improvement (30%) was noted for the Dzingahe and Tshedza plants, followed by the Malamulele plant, while the Mutale, Vondo, and Mutshedzi plants improved their scores by 20%, 17% and 14%, respectively. After corrective actions and re-measurement, no plant complied. It is recommended that Water Services Providers (WSPs) regularly apply the diagnostic tools and water safety plans as developed in order to comply with applicable standards.

  8. The Limpopo Non-Metropolitan Drinking Water Supplier Response to a Diagnostic Tool for Technical Compliance

    Directory of Open Access Journals (Sweden)

    Avhashoni D. Nefale

    2017-07-01

    Full Text Available Water services providers should supply water that is fit for human consumption, taking into account multi-barrier approaches and technical aspects such as design aspects, operation monitoring, final water quality compliance monitoring, plant monitoring practices, maintenance, and risk management practices. Against this background, this study focused on applying the diagnostic tool for technical compliance as well as assessing the compliance of water treatment plants with management norms. Six plants in the Vhembe District Municipality were selected; the Vondo, Malamulele, Mutshedzi, and Mutale plants (conventional, and the Dzingahe and Tshedza package plants. During the first assessment, four (Malamulele, Mutshedzi, Mutale and Dzingahe plants scored between 44% and 49% and achieved Class 3 certification, revealing serious challenges requiring immediate intervention. Two water plants (Vondo and Tshedza, scoring 53% and 63%, respectively were in the Class 2 category, revealing serious challenges requiring attention and improvement. During the second assessment, all plants scored between 63% and 87% (Class 2 category. The greatest improvement (30% was noted for the Dzingahe and Tshedza plants, followed by the Malamulele plant, while the Mutale, Vondo, and Mutshedzi plants improved their scores by 20%, 17% and 14%, respectively. After corrective actions and re-measurement, no plant complied. It is recommended that Water Services Providers (WSPs regularly apply the diagnostic tools and water safety plans as developed in order to comply with applicable standards.

  9. The three-dimensional positioning system at the VINETA.II experiment—a multipurpose tool for in situ plasma diagnostics

    Science.gov (United States)

    Shesterikov, I.; Milojevic, D.; von Stechow, A.; Rahbarnia, K.; Grulke, O.; Klinger, T.

    2017-08-01

    The manipulator systems installed at the VINETA.II magnetic reconnection experiment are essential elements for experimental investigation of local plasma parameters. A novel three-dimensional (3D) probe manipulator has been designed, implemented and successfully operated at VINETA.II. This work presents its design and performance for three-dimensional measurements of VINETA.II plasmas. Its design consists of three vertically stacked independent and mutually perpendicular linear motion stages which allow flexible positioning of diagnostic tools such as electrical and magnetic probes or optical diagnostics within the vacuum vessel. Its design features include a wide spatial coverage, sub-millimeter positioning accuracy and the capability to operate in a harsh environment under the influence of microwaves, radio-frequency waves and direct contact with plasma. Manipulator performance is assessed by measuring a volumetric distribution of plasma parameters by a B-dot probe. A typical discharge of the magnetic reconnection setup in VINETA.II with a pulse time of τ=600 μs is chosen for this purpose. The azimuthal magnetic field distribution measured with the 3D manipulator agrees favorably with measurements obtained by the two-dimensional (2D) manipulator, used at VINETA.II as a standard reference diagnostic tool, thereby demonstrating its reliability and performance. A programmable stepper motor controller (TMCM-1110) that is operated remotely by a PC drives all possible features of the manipulator system.

  10. Psychometric Properties of the Iranian Version of the Premature Ejaculation Diagnostic Tool

    Directory of Open Access Journals (Sweden)

    Amir H. Pakpour, PhD

    2014-04-01

    Conclusion: The results provide evidence for good reliability and validity of the Iranian version of the PEDT. The questionnaire therefore represents a suitable tool for screening PE in Iranian men. Pakpour AH, Yekaninejad MS, Nikoobakht MR, Burri A, and Fridlund B. Psychometric properties of the Iranian version of the Premature Ejaculation Diagnostic Tool. Sex Med 2014;2:31–40.

  11. Assessing use of a standardized dental diagnostic terminology in an electronic health record

    NARCIS (Netherlands)

    Tokede, O.; White, J.; Stark, P.C.; Vaderhobli, R.; Walji, M.F.; Ramoni, R.; Schoonheim-Klein, M.; Kimmes, N.; Tavares, A.; Kalenderian, E.

    2013-01-01

    Although standardized terminologies such as the International Classification of Diseases have been in use in medicine for over a century, efforts in the dental profession to standardize dental diagnostic terms have not achieved widespread acceptance. To address this gap, a standardized dental

  12. Establishment of standard x-ray qualities to be used in diagnostic level at SSDLs

    International Nuclear Information System (INIS)

    A-Aziz, R.O.

    2007-08-01

    The objective of the present work is to modify x-ray machine (used by the secondary standard dosimetry laboratory in Sudan) to produce x-ray qualities suitable for the calibration at diagnostic level. It based on experimental evaluations. The importance of this study appears in development of protocols to calibrate the instruments used in diagnostic radiology in by good response of the instruments and low cost. In particular, the half value layer (HVL) values for the following qualities 40, 60, 80, 100, 120 and 150 were determined using various attenuation layers. Ionization chamber was used to determine the free air kerma rate at a distance of 100 cm from the x-ray generator. The obtained HVL values were compared with standard values of diagnostic levels. It was observed that the HVL of the present x-ray machine in most qualities are smaller than the standard ones. An approved method (described in the standard IEC 61267) was applied to determine the amount of additional filtration required to meet the standard values. The results show that the available cupper layers were not suitable for this purpose as most of the x-ray was absorbed in the material. Aluminum layers, on the other hand , show good performances to reduce the beams to the desired levels. The amount of additional filtration (from aluminum layers) needed in order to establish standard x-ray qualities to be used in diagnostic level were determined.(Author)

  13. Molecular Tools for Diagnosis of Visceral Leishmaniasis: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy

    Science.gov (United States)

    de Ruiter, C. M.; van der Veer, C.; Leeflang, M. M. G.; Deborggraeve, S.; Lucas, C.

    2014-01-01

    Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that evaluate the sensitivities and specificities of molecular tests for diagnosis of VL, adequate classification of study participants, and the absolute numbers of true positives and negatives derivable from the data presented. Forty studies met the selection criteria, including PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), and loop-mediated isothermal amplification (LAMP). The sensitivities of the individual studies ranged from 29 to 100%, and the specificities ranged from 25 to 100%. The pooled sensitivity of PCR in whole blood was 93.1% (95% confidence interval [CI], 90.0 to 95.2), and the specificity was 95.6% (95% CI, 87.0 to 98.6). The specificity was significantly lower in consecutive studies, at 63.3% (95% CI, 53.9 to 71.8), due either to true-positive patients not being identified by parasitological methods or to the number of asymptomatic carriers in areas of endemicity. PCR for patients with HIV-VL coinfection showed high diagnostic accuracy in buffy coat and bone marrow, ranging from 93.1 to 96.9%. Molecular tools are highly sensitive assays for Leishmania detection and may contribute as an additional test in the algorithm, together with a clear clinical case definition. We observed wide variety in reference standards and study designs and now recommend consecutively designed studies. PMID:24829226

  14. The Autism Diagnostic Observation Schedule--Toddler Module: A New Module of a Standardized Diagnostic Measure for Autism Spectrum Disorders

    Science.gov (United States)

    Luyster, Rhiannon; Gotham, Katherine; Guthrie, Whitney; Coffing, Mia; Petrak, Rachel; Pierce, Karen; Bishop, Somer; Esler, Amy; Hus, Vanessa; Oti, Rosalind; Richler, Jennifer; Risi, Susan; Lord, Catherine

    2009-01-01

    The Autism Diagnostic Observation Schedule (ADOS; Lord et al., J Autism Dev Disord, 30(3):205-223, 2000) is widely accepted as a "gold standard" diagnostic instrument, but it is of restricted utility with very young children. The purpose of the current project was to modify the ADOS for use in children under 30 months of age. A modified ADOS, the…

  15. Case Report: SPECT/CT as the New Diagnostic Tool for Specific Wrist Pathology.

    Science.gov (United States)

    Linde, Musters; Ten Broek, M; Kraan, G A

    2017-01-01

    Single photon emission computed tomography has been introduced as a promising new diagnostic tool in orthopaedic pathology since the early 90'. Computed tomography, the combined with SPECT, gives insight in the specific sight of wrist pathology. Literature already supports introduction of SPECT/CT in wrist pathology, but clinical application is lagging. A 40yr old patient reported first in 2004 with persisting pain after a right distal radius fracture. Several diagnostics and operative interventions were performed, all unsuccessful. Because of the persisting pain a SPECT-CT was performed which showed a cyst in the hamate bone, which was successfully enucleated. The patient was finally pain free at recent follow-up. With a QDash-score of 43 and a PRW (H) E-DLV-score of 58/150. In this case report, SPECT/CT proved a very sensitive diagnostic tool for specific pathology of the wrist. It offered precise localisation and thereby the clinically suspected diagnosis was confirmed and the patient successfully treated.

  16. Delving into cornerstones of hypersensitivity to antineoplastic and biological agents: value of diagnostic tools prior to desensitization.

    Science.gov (United States)

    Alvarez-Cuesta, E; Madrigal-Burgaleta, R; Angel-Pereira, D; Ureña-Tavera, A; Zamora-Verduga, M; Lopez-Gonzalez, P; Berges-Gimeno, M P

    2015-07-01

    Evidence regarding drug provocation test (DPT) with antineoplastic and biological agents is scarce. Our aim was to assess the usefulness of including DPT as a paramount gold standard diagnostic tool (prior to desensitization). Prospective, observational, longitudinal study with patients who, during a 3-year period, were referred to the Desensitization Program at Ramon y Cajal University Hospital. Patients underwent a structured diagnostic protocol by means of anamnesis, skin tests (ST), risk assessment, and DPT. Oxaliplatin-specific IgE was determined in oxaliplatin-reactive patients (who underwent DPT regardless of oxaliplatin-specific IgE results). Univariate analysis and multivariate analysis were used to identify predictors of the final diagnosis among several variables. A total of 186 patients were assessed. A total of 104 (56%) patients underwent DPT. Sixty-four percent of all DPTs were negative (i.e., hypersensitivity was excluded). Sensitivity for oxaliplatin-specific IgE (0.35 UI/l cutoff point) was 34%, specificity 90.3%, negative predictive value 45.9%, positive predictive value 85%, negative likelihood ratio 0.7, and positive likelihood ratio 3.5. These are the first reported data based on more than 100 DPTs with antineoplastic and biological agents (paclitaxel, oxaliplatin, rituximab, infliximab, irinotecan, and other drugs). Implementation of DPT in diagnostic protocols helps exclude hypersensitivity (in 36% of all referred patients), and avoids unnecessary desensitizations in nonhypersensitive patients (30-56% of patients, depending on culprit-drug). Drug provocation test is vital to validate diagnostic tools; consequently, quality data are shown on oxaliplatin-specific IgE and oxaliplatin-ST in the largest series of oxaliplatin-reactive patients reported to date (74 oxaliplatin-reactive patients). Identifying phenotypes and predictors of a diagnosis of hypersensitivity may be helpful for tailored plans. © 2015 John Wiley & Sons A/S. Published by

  17. STARD-BLCM: Standards for the Reporting of Diagnostic accuracy studies that use Bayesian Latent Class Models

    DEFF Research Database (Denmark)

    Kostoulas, Polychronis; Nielsen, Søren S.; Branscum, Adam J.

    2017-01-01

    The Standards for the Reporting of Diagnostic Accuracy (STARD) statement, which was recently updated to the STARD2015 statement, was developed to encourage complete and transparent reporting of test accuracy studies. Although STARD principles apply broadly, the checklist is limited to studies......-BLCM (Standards for Reporting of Diagnostic accuracy studies that use Bayesian Latent Class Models), will facilitate improved quality of reporting on the design, conduct and results of diagnostic accuracy studies that use Bayesian latent class models....

  18. CRISP. Simulation tool for fault detection and diagnostics in high-DG power networks

    International Nuclear Information System (INIS)

    Fontela, M.; Andrieu, C.; Raison, B.

    2004-08-01

    This document gives a description of a tool proposed for fault detection and diagnostics. The main principles of the functions of fault localization are described and detailed for a given MV network that will be used for the ICT experiment in Grenoble (experiment 3B). The aim of the tool is to create a technical, simple and realistic context for testing ICT dedicated to an electrical application. The tool gives the expected inputs and outputs contents of the various distributed ICT components when a fault occurs in a given MV network. So the requirements for the ICT components are given in term of expected data collected, analysed and transmitted. Several examples are given in order to illustrate the inputs/outputs in case of different faults. The tool includes a topology description which is a main aspect to develop in the future for managing the distribution network. Updating topology in real time will become necessary for fault diagnostic and protection, but also necessary for the various possible added applications (local market balance and local electrical power quality for instance). The tool gives a context and a simple view for the ICT components behaviours assuming an ideal response and transmission from them. The real characteristics and possible limitations for the ICT (information latency, congestion, security) will be established during the experiments from the same context described in the HTFD tool

  19. Lessons learned developing a diagnostic tool for HIV-associated dementia feasible to implement in resource-limited settings: pilot testing in Kenya.

    Directory of Open Access Journals (Sweden)

    Judith Kwasa

    Full Text Available To conduct a preliminary evaluation of the utility and reliability of a diagnostic tool for HIV-associated dementia (HAD for use by primary health care workers (HCW which would be feasible to implement in resource-limited settings.In resource-limited settings, HAD is an indication for anti-retroviral therapy regardless of CD4 T-cell count. Anti-retroviral therapy, the treatment for HAD, is now increasingly available in resource-limited settings. Nonetheless, HAD remains under-diagnosed likely because of limited clinical expertise and availability of diagnostic tests. Thus, a simple diagnostic tool which is practical to implement in resource-limited settings is an urgent need.A convenience sample of 30 HIV-infected outpatients was enrolled in Western Kenya. We assessed the sensitivity and specificity of a diagnostic tool for HAD as administered by a primary HCW. This was compared to an expert clinical assessment which included examination by a physician, neuropsychological testing, and in selected cases, brain imaging. Agreement between HCW and an expert examiner on certain tool components was measured using Kappa statistic.The sample was 57% male, mean age was 38.6 years, mean CD4 T-cell count was 323 cells/µL, and 54% had less than a secondary school education. Six (20% of the subjects were diagnosed with HAD by expert clinical assessment. The diagnostic tool was 63% sensitive and 67% specific for HAD. Agreement between HCW and expert examiners was poor for many individual items of the diagnostic tool (K = .03-.65. This diagnostic tool had moderate sensitivity and specificity for HAD. However, reliability was poor, suggesting that substantial training and formal evaluations of training adequacy will be critical to enable HCW to reliably administer a brief diagnostic tool for HAD.

  20. Beam diagnostic tools for the negative hydrogen ion source test facility ELISE

    International Nuclear Information System (INIS)

    Nocentini, Riccardo; Fantz, Ursel; Franzen, Peter; Froeschle, Markus; Heinemann, Bernd; Riedl, Rudolf; Ruf, Benjamin; Wuenderlich, Dirk

    2013-01-01

    Highlights: ► We present an overview of beam diagnostic tools foreseen for the new testbed ELISE. ► A sophisticated diagnostic calorimeter allows beam profile measurement. ► A tungsten wire mesh in the beam path provides a qualitative picture of the beam. ► Stripping losses and beam divergence are measured by H α Doppler shift spectroscopy. -- Abstract: The test facility ELISE, presently being commissioned at IPP, is a first step in the R and D roadmap for the RF driven ion source and extraction system of the ITER NBI system. The “half-size” ITER-like test facility includes a negative hydrogen ion source that can be operated for 1 h. ELISE is expected to extract an ion beam of 20 A at 60 kV for 10 s every 3 min, therefore delivering a total power of 1.2 MW. The extraction area has a geometry that closely reproduces the ITER design, with the same width and half the height, i.e. 1 m × 1 m. This paper presents an overview of beam diagnostic tools foreseen for ELISE. For the commissioning phase, a simple beam dump with basic diagnostic capabilities has been installed. In the second phase, the beam dump will be substituted by a more sophisticated diagnostic calorimeter to allow beam profile measurement. Additionally, a tungsten wire mesh will be introduced in the beam path to provide a qualitative picture of beam size and position. Stripping losses and beam divergence will be measured by means of H α Doppler shift spectroscopy. An absolute calibration is foreseen in order to measure beam intensity

  1. THE CONFORMITY OF MACHINE TOOLS WITH RESPECT TO EUROPEAN SAFETY STANDARDS

    CERN Multimedia

    TIS/TE

    2001-01-01

    European regulations require that all motorized machine tools conform to the latest safety standards by the end of the year 2000. CERN must follow these regulations and has already modified most of its machine tools accordingly. However, there is still a small number of machine tools which have not yet been modified as required. These machines should not be used until they are brought up to the required safety standards, failing which the machines should be discarded. One can recognise which machine tools conform with the latest standards by the indication 'CS' on the identification plate of the machine, see foto below. In cases of doubt about the status of a machine tool you should contact K. Altherr/EST or C. Margaroli/TIS for advice.

  2. THE CONFORMITY OF MACHINE TOOLS WITH RESPECT TO EUROPEAN SAFETY STANDARDS

    CERN Multimedia

    TIS/TE

    2000-01-01

    European regulations require that all motorized machine tools conform to the latest safety standards by the end of the year 2000. CERN must follow these regulations and has already modified most of its machine tools accordingly. However, there is still a small number of machine tools which have not yet been modified as required. These machines should not be used until they are brought up to the required safety standards, failing which the machines should be discarded. One can recognise which machine tools conform with the latest standards by the indication 'CS' on the identification plate of the machine, see foto below. In cases of doubt about the status of a machine tool you should contact K. Altherr/EST or C. Margaroli/TIS for advice.

  3. Molecular tools for diagnosis of visceral leishmaniasis: systematic review and meta-analysis of diagnostic test accuracy.

    Science.gov (United States)

    de Ruiter, C M; van der Veer, C; Leeflang, M M G; Deborggraeve, S; Lucas, C; Adams, E R

    2014-09-01

    Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that evaluate the sensitivities and specificities of molecular tests for diagnosis of VL, adequate classification of study participants, and the absolute numbers of true positives and negatives derivable from the data presented. Forty studies met the selection criteria, including PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), and loop-mediated isothermal amplification (LAMP). The sensitivities of the individual studies ranged from 29 to 100%, and the specificities ranged from 25 to 100%. The pooled sensitivity of PCR in whole blood was 93.1% (95% confidence interval [CI], 90.0 to 95.2), and the specificity was 95.6% (95% CI, 87.0 to 98.6). The specificity was significantly lower in consecutive studies, at 63.3% (95% CI, 53.9 to 71.8), due either to true-positive patients not being identified by parasitological methods or to the number of asymptomatic carriers in areas of endemicity. PCR for patients with HIV-VL coinfection showed high diagnostic accuracy in buffy coat and bone marrow, ranging from 93.1 to 96.9%. Molecular tools are highly sensitive assays for Leishmania detection and may contribute as an additional test in the algorithm, together with a clear clinical case definition. We observed wide variety in reference standards and study designs and now recommend consecutively designed studies. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  4. Lacrimination in Sjogren′s syndrome. Is Schirmer′s test really a useful diagnostic tool?

    Directory of Open Access Journals (Sweden)

    Bhadoria D

    1988-01-01

    Full Text Available In the past, Schinier′s test was used as a diagnostic tool in Sjogren′s Syndrome. In this study, a comparison of 100 normal patients with 2l patients with Sjogren′s Syndrome has been made to study its reliability. It has been concluded that Schimer′s test is of a poor diagnostic value in Sjogren′s Syndrome.

  5. A miRNA expression based diagnostic tool for breast cancer using random forests

    OpenAIRE

    Wenric, Stéphane; Freres, Pierre; Josse, Claire; Bours, Vincent; Jerusalem, Guy

    2013-01-01

    We developed a novel diagnostic tool for breast cancer using circulating miRNA expression levels as features of a supervised machine learning problem. We showed very good results on an independent validation cohort.

  6. 18F-DOPA PET/CT and 68Ga-DOTANOC PET/CT scans as diagnostic tools in focal congenital hyperinsulinism

    DEFF Research Database (Denmark)

    Christiansen, Charlotte Dahl; Petersen, Henrik; Nielsen, Anne Lerberg

    2018-01-01

    (68Ga-DOTANOC) PET/CT as diagnostic tools in focal CHI. Methods: PET/CT scans of children with CHI admitted to Odense University Hospital between August 2005 and June 2016 were retrospectively evaluated visually and by their maximal standardized uptake values (SUVmax) by two independent examiners......, blinded for clinical, surgical and pathological data. Pancreatic histology was used as the gold standard. For patients without surgery, the genetic profile served as the gold standard. Results: Fifty-five CHI patients were examined by PET/CT (18F-DOPA n = 53, 68Ga-DOTANOC n = 18). Surgery was performed...... in 34 patients, no surgery in 21 patients. Fifty-one patients had a classifiable outcome, either by histology (n = 33, 22 focal lesions, 11 non-focal) or by genetics (n = 18, all non-focal). The predictive performance of 18F-DOPA PET/CT to identify focal CHI was identical by visual- and cut...

  7. Monitoring the International Standardization Process Theoretical Choices and Methodological Tools

    Directory of Open Access Journals (Sweden)

    Brigitte Juanals

    2012-08-01

    Full Text Available Many organizations are in charge of global security management. This paper outlines and argues for the construction of a theoretical and methodological framework in order to critically assess the new technopolitics currently being developed in the field of global security and which are materialized in standards. The main purpose is to design both a methodology and specific text mining tools to investigate these standards. These tools will be implemented in a platform designed to provide cartographic representations of standards and to assist the navigation of an end-user through a corpus of standards.

  8. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  9. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  10. Proposals for new standardized general diagnostic criteria for the secondary headaches

    DEFF Research Database (Denmark)

    Olesen, J; Steiner, T; Bousser, M-G

    2009-01-01

    headache and chronic migraine. These changes made apparent a further need for broader revisions to the standard formulation of diagnostic criteria for the secondary headaches. Currently, the fourth criterion makes impossible the definitive diagnosis of a secondary headache until the underlying cause has...... propose maintaining a standard approach to the secondary headaches using a set of four criteria A, B, C and D, but we construct these so that the requirement for resolution or successful treatment is removed. The proposal for general diagnostic criteria for the secondary headaches will be entered...... classification are then foreseen for the next 10 years. Until the printing of ICHD-IIR, the printed ICHD-II criteria remain in place for all other purposes. We issue a plea to the headache community to use and study these proposed general criteria for the secondary headaches in order to provide more evidence...

  11. Acute-phase proteins: As diagnostic tool

    Directory of Open Access Journals (Sweden)

    Sachin Jain

    2011-01-01

    Full Text Available The varied reactions of the host to infection, inflammation, or trauma are collectively known as the acute-phase response and encompass a wide range of pathophysiological responses such as pyrexia, leukocytosis, hormone alterations, and muscle protein depletion combining to minimize tissue damage while enhancing the repair process. The mechanism for stimulation of hepatic production of acute-phase proteins is by proinflammatory cytokines. The functions of positive acute-phase proteins (APP are regarded as important in optimization and trapping of microorganism and their products, in activating the complement system, in binding cellular remnants like nuclear fractions, in neutralizing enzymes, scavenging free hemoglobin and radicals, and in modulating the host′s immune response. APP can be used as diagnostic tool in many diseases like bovine respiratory syncytial virus, prostate cancer, bronchopneumonia, multiple myeloma, mastitis, Streptococcus suis infection, starvation, or lymphatic neoplasia. Thus, acute-phase proteins may provide an alternative means of monitoring animal health.

  12. A Standardized Diagnostic Interview for Hypoactive Sexual Desire Disorder in Women

    DEFF Research Database (Denmark)

    Bitzer, Johannes; Giraldi, Annamaria; Pfaus, Jim

    2012-01-01

    procedure that is patient centered and multidimensional. Aim.  Describing a patient-centered and multidimensional standard procedure to diagnose and manage HSDD on a primary care level. Methods.  Review of the literature. Semistructured interview and description of process. Result.  The interactive process...... with the patient follows several steps: initiation, narrative of the patient to understand the individual profile of the disorder, differentiating questions, descriptive diagnosis, exploration of conditioning biomedical, individual psychological, interpersonal, and sociocultural factors (including biomedical......, and Pfaus J. A standardized diagnostic interview for Hypoactive Sexual Desire Disorder in women: standard operating procedure (SOP part 2). J Sex Med **;**:**-**....

  13. Diagnostic tools used in the calibration and verification of protein crystallography synchrotron beam lines and apparatus

    International Nuclear Information System (INIS)

    Rotella, F.J.; Alkire, R.W.; Duke, N.E.C.; Molitsky, M.J.

    2011-01-01

    Diagnostic tools have been developed for use at the Structural Biology Center beam lines at the Advanced Photon Source. These tools are used in the calibration and operating verification of these synchrotron X-ray beam lines and constituent equipment.

  14. Tool coupling for the design and operation of building energy and control systems based on the Functional Mock-up Interface standard

    Energy Technology Data Exchange (ETDEWEB)

    Nouidui, Thierry Stephane; Wetter, Michael

    2014-03-01

    This paper describes software tools developed at the Lawrence Berkeley National Laboratory (LBNL) that can be coupled through the Functional Mock-up Interface standard in support of the design and operation of building energy and control systems. These tools have been developed to address the gaps and limitations encountered in legacy simulation tools. These tools were originally designed for the analysis of individual domains of buildings, and have been difficult to integrate with other tools for runtime data exchange. The coupling has been realized by use of the Functional Mock-up Interface for co-simulation, which standardizes an application programming interface for simulator interoperability that has been adopted in a variety of industrial domains. As a variety of coupling scenarios are possible, this paper provides users with guidance on what coupling may be best suited for their application. Furthermore, the paper illustrates how tools can be integrated into a building management system to support the operation of buildings. These tools may be a design model that is used for real-time performance monitoring, a fault detection and diagnostics algorithm, or a control sequence, each of which may be exported as a Functional Mock-up Unit and made available in a building management system as an input/output block. We anticipate that this capability can contribute to bridging the observed performance gap between design and operational energy use of buildings.

  15. Diagnostic tool for structural health monitoring: effect of material nonlinearity and vibro-impact process

    Science.gov (United States)

    Hiwarkar, V. R.; Babitsky, V. I.; Silberschmidt, V. V.

    2013-07-01

    Numerous techniques are available for monitoring structural health. Most of these techniques are expensive and time-consuming. In this paper, vibration-based techniques are explored together with their use as diagnostic tools for structural health monitoring. Finite-element simulations are used to study the effect of material nonlinearity on dynamics of a cracked bar. Additionally, several experiments are performed to study the effect of vibro-impact behavior of crack on its dynamics. It was observed that a change in the natural frequency of the cracked bar due to crack-tip plasticity and vibro-impact behavior linked to interaction of crack faces, obtained from experiments, led to generation of higher harmonics; this can be used as a diagnostic tool for structural health monitoring.

  16. Report on design rules of μ-tools for standard insert

    DEFF Research Database (Denmark)

    Tosello, Guido; Esmoris, Josa Ignacio; Quadroni, A.

    2011-01-01

    -effectively, especially for micro injection moulding. This particular deliverable has the objective to present the design rules for high performance μ-tools and inserts manufacture based on the new standard manufacturing process chains established during the WP 2.2 work. In particular, the achievable features, surfaces......Tooling is one of the critical stages of the process chain for polymer micro products manufacture and in particular for the COTECH process chain. Therefore, within the scope of SP2 “Tooling”, the WP 2.2 “New tool-making solutions for μ-IM and HE” is designed to investigate, develop and standardize...

  17. Granular filters for water treatment: heterogeneity and diagnostic tools

    DEFF Research Database (Denmark)

    Lopato, Laure Rose

    the last barrier against disinfection resistant protozoan pathogens and this has led to increased regulation of the filtration process. To be able to produce high-quality filtrate in a constant and reliable manner while meeting stricter drinking water guideline values, it is important to be able......Rapid granular filters are the most commonly used filters in drinking water treatment plants and are the focus of this PhD study. They are usually constructed with sand, anthracite, activated carbon, garnet sand, and ilmenite and have filtration rates ranging from 3 to 15 m/h. Filters are often...... options prescribed. The diagnostic tools are then used again to verify the efficiency of the solution applied. If the problem is not solved the whole process starts again. These tools are of significant interest for the development of the Water Safety Plans recommended by WHO to monitor filters...

  18. The diagnostic path, a useful visualisation tool in virtual microscopy.

    Science.gov (United States)

    Schrader, Thomas; Niepage, Sonja; Leuthold, Thomas; Saeger, Kai; Schluns, Karsten; Hufnagl, Peter; Kayser, Klaus; Dietel, Manfred

    2006-11-08

    The Virtual Microscopy based on completely digitalised histological slide. Concerning this digitalisation many new features in mircoscopy can be processed by the computer. New applications are possible or old, well known techniques of image analyses can be adapted for routine use. A so called diagnostic path observes in the way of a professional sees through a histological virtual slide combined with the text information of the dictation process. This feature can be used for image retrieval, quality assurance or for educational purpose. The diagnostic path implements a metadata structure of image information. It stores and processes the different images seen by a pathologist during his "slide viewing" and the obtained image sequence ("observation path"). Contemporary, the structural details of the pathology reports were analysed. The results were transferred into an XML structure. Based on this structure, a report editor and a search function were implemented. The report editor compiles the "diagnostic path", which is the connection from the image viewing sequence ("observation path") and the oral report sequence of the findings ("dictation path"). The time set ups of speech and image viewing serve for the link between the two sequences. The search tool uses the obtained diagnostic path. It allows the user to search for particular histological hallmarks in pathology reports and in the corresponding images. The new algorithm was tested on 50 pathology reports and 74 attached histological images. The creation of a new individual diagnostic path is automatically performed during the routine diagnostic process. The test prototype experienced an insignificant prolongation of the diagnosis procedure (oral case description and stated diagnosis by the pathologist) and a fast and reliable retrieval, especially useful for continuous education and quality control of case description and diagnostic work. The Digital Virtual Microscope has been designed to handle 1000 images

  19. Ultrasound elastography as an objective diagnostic measurement tool for lymphoedema of the treated breast in breast cancer patients following breast conserving surgery and radiotherapy

    International Nuclear Information System (INIS)

    Adriaenssens, Nele; Belsack, Dries; Buyl, Ronald; Ruggiero, Leonardo; Breucq, Catherine; De Mey, Johan; Lievens, Pierre; Lamote, Jan

    2012-01-01

    Lymphoedema of the operated and irradiated breast is a common complication following early breast cancer treatment. There is no consensus on objective diagnostic criteria and standard measurement tools. This study investigates the use of ultrasound elastography as an objective quantitative measurement tool for the diagnosis of parenchymal breast oedema. The elasticity ratio of the subcutis, measured with ultrasound elastography, was compared with high-frequency ultrasound parameters and subjective symptoms in twenty patients, bilaterally, prior to and following breast conserving surgery and breast irradiation. Elasticity ratio of the subcutis of the operated breast following radiation therapy increased in 88.9% of patients, was significantly higher than prior to surgery, unlike the non operated breast and significantly higher than the non operated breast, unlike preoperative results. These results were significantly correlated with visibility of the echogenic line, measured with high-frequency ultrasound. Big preoperative bra cup size was a significant risk factor for the development of breast oedema. Ultrasound elastography is an objective quantitative measurement tool for the diagnosis of parenchymal breast oedema, in combination with other objective diagnostic criteria. Further research with longer follow-up and more patients is necessary to confirm our findings

  20. Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System

    CERN Document Server

    Wu, Juhao; Huang, Zhirong

    2005-01-01

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as the diagnostic tool for bunch length feedback. Calculations show that CSR is a good candidate, even for the non-Gaussian, double-horn longitudinal charge distribution. We further check the feasibility for low and high charge options, and also the possibility for detecting the microbunching.

  1. Molecular tools for diagnosis of visceral leishmaniasis: systematic review and meta-analysis of diagnostic test accuracy

    NARCIS (Netherlands)

    de Ruiter, C. M.; van der Veer, C.; Leeflang, M. M. G.; Deborggraeve, S.; Lucas, C.; Adams, E. R.

    2014-01-01

    Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that

  2. Non-Metropolitan Drinking Water Suppliers’ Response to the Diagnostic Tool for Non-Technical Compliance in Limpopo, South Africa

    Directory of Open Access Journals (Sweden)

    Avhashoni Dorcas Nefale

    2017-11-01

    Full Text Available Without the planning of non-technical issues, water treatment plants may face challenges in sustaining safe drinking water. Parameters such as the planning of financial resources, human resources, a lack of professional process controllers, poor working conditions, staff shortages and a lack of appropriate training of process controllers contribute to the underperformance of drinking water treatment plants. This study aimed at applying the Diagnostic Tool for Non-Technical Compliance to assess the compliance of small drinking water plants with management norms. Six water treatments (Vondo water scheme, Malamulele, Mutshedzi, Mutale regional water treatment plant, Tshedza and Tshedza package plant were selected from the Vhembe district municipality of the Limpopo province in South Africa. From the abovementioned non-technical parameters, the results showed that during the first assessment period (August 2008 and June 2009 selected water treatment plants scored between 53% and 68% and fell under Class 2, indicating serious challenges requiring attention and improvement. During the second assessment period (November and December 2010, a slight improvement was observed as all plants scored between 72% and 80%, falling under the Class 2 category. Even after corrective actions and remeasurement, none of the plants met the compliance standards, which range from 90% to 100% to obtain the Class 1 compliance standard. The study recommended that tactical and strategic plans that clearly define the operational procedures, process controlling, financial planning, maintenance culture, emergency preparedness and regular monitoring and evaluation should be entrenched for the smooth running of the small water treatment plants. Furthermore, all water services providers and water services authorities should apply the diagnostic tools as developed, which provides guidance on a stepwise procedure on plant operations and management on a daily basis.

  3. [The challenges of standardization in clinical diagnostic laboratories of medical organizations].

    Science.gov (United States)

    Men'shikov, V V

    2013-04-01

    The generalized data concerning the conditions of application of regulations of national standards in clinical diagnostic laboratories of medical organizations is presented. The primary information was provided by 14 regions of 6 federal administrative okrugs of Russia. The causes of challenges of application of requirements of standards are presented. They are mostly related with insufficient financial support, lacking of manpower, difficulties with reagents supply, inadequate technical maintenance of devices and absence of support of administration of medical organizations. The recommendations are formulated concerning the necessity of publishing the document of Minzdrav of Russia to determine the need in application of standards in laboratory practice.

  4. Salivary glucose as a diagnostic tool in Type II diabetes mellitus: A ...

    African Journals Online (AJOL)

    2015-11-02

    Nov 2, 2015 ... glucose level is the key to both diagnosis and management of ... diagnostic, as well as a monitoring tool to assess the glycemic status of Type II ..... Priya SS, Bharani GO, Nagalingam M, Jayanthi M, Kanagavalli U. Potential of ... Agrawal RP, Sharma N, Rathore MS, Gupta VB, Jain S, Agarwal V, et al.

  5. Rapid molecular diagnostics for multi-drug resistant tuberculosis in India.

    Science.gov (United States)

    Ramachandran, Rajeswari; Muniyandi, M

    2018-03-01

    Rapid molecular diagnostic methods help in the detection of TB and Rifampicin resistance. These methods detect TB early, are accurate and play a crucial role in reducing the burden of drug resistant tuberculosis. Areas covered: This review analyses rapid molecular diagnostic tools used in the diagnosis of MDR-TB in India, such as the Line Probe Assay and GeneXpert. We have discussed the burden of MDR-TB and the impact of recent diagnostic tools on case detection and treatment outcomes. This review also discusses the costs involved in establishing these new techniques in India. Expert commentary: Molecular methods have considerable advantages for the programmatic management of drug resistant TB. These include speed, standardization of testing, potentially high throughput and reduced laboratory biosafety requirements. There is a desperate need for India to adopt modern, rapid, molecular tools with point-of-care tests being currently evaluated. New molecular diagnostic tests appear to be cost effective and also help in detecting missing cases. There is enough evidence to support the scaling up of these new tools in India.

  6. Evaluation of the Standard Diagnostics Leptospira IgM ELISA for diagnosis of acute leptospirosis in Lao PDR

    NARCIS (Netherlands)

    Tanganuchitcharnchai, Ampai; Smythe, Lee; Dohnt, Michael; Hartskeerl, Rudy; Vongsouvath, Manivanh; Davong, Viengmone; Lattana, Olay; Newton, Paul N.; Blacksell, Stuart D.

    2012-01-01

    The diagnostic utility of the Standard Diagnostics Leptospira IgM ELISA for detection of acute leptospirosis was assessed in febrile adults admitted in Vientiane, Laos. Using the cut-off suggested by the manufacturer [optical density (OD) >= 0.75], the assay demonstrated limited diagnostic capacity

  7. Standard Mutation Nomenclature in Molecular Diagnostics

    Science.gov (United States)

    Ogino, Shuji; Gulley, Margaret L.; den Dunnen, Johan T.; Wilson, Robert B.

    2007-01-01

    To translate basic research findings into clinical practice, it is essential that information about mutations and variations in the human genome are communicated easily and unequivocally. Unfortunately, there has been much confusion regarding the description of genetic sequence variants. This is largely because research articles that first report novel sequence variants do not often use standard nomenclature, and the final genomic sequence is compiled over many separate entries. In this article, we discuss issues crucial to clear communication, using examples of genes that are commonly assayed in clinical laboratories. Although molecular diagnostics is a dynamic field, this should not inhibit the need for and movement toward consensus nomenclature for accurate reporting among laboratories. Our aim is to alert laboratory scientists and other health care professionals to the important issues and provide a foundation for further discussions that will ultimately lead to solutions. PMID:17251329

  8. Assessing the accuracy of forecasting: applying standard diagnostic assessment tools to a health technology early warning system.

    Science.gov (United States)

    Simpson, Sue; Hyde, Chris; Cook, Alison; Packer, Claire; Stevens, Andrew

    2004-01-01

    Early warning systems are an integral part of many health technology assessment programs. Despite this finding, to date, there have been no quantitative evaluations of the accuracy of predictions made by these systems. We report a study evaluating the accuracy of predictions made by the main United Kingdom early warning system. As prediction of impact is analogous to diagnosis, a method normally applied to determine the accuracy of diagnostic tests was used. The sensitivity, specificity, and predictive values of the National Horizon Scanning Centre's prediction methods were estimated with reference to an (imperfect) gold standard, that is, expert opinion of impact 3 to 5 years after prediction. The sensitivity of predictions was 71 percent (95 percent confidence interval [CI], 0.36-0.92), and the specificity was 73 percent (95 percent CI, 0.64-0.8). The negative predictive value was 98 percent (95 percent CI, 0.92-0.99), and the positive predictive value was 14 percent (95 percent CI, 0.06-0.3). Forecasting is difficult, but the results suggest that this early warning system's predictions have an acceptable level of accuracy. However, there are caveats. The first is that early warning systems may themselves reduce the impact of a technology, as helping to control adoption and diffusion is their main purpose. The second is that the use of an imperfect gold standard may bias the results. As early warning systems are viewed as an increasingly important component of health technology assessment and decision making, their outcomes must be evaluated. The method used here should be investigated further and the accuracy of other early warning systems explored.

  9. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  10. MODIFIED ALVARADO SCORING AS A DIAGNOSTIC TOOL IN ACUTE APPENDICITIS- A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    V. K. Arun Kumar

    2017-02-01

    Full Text Available BACKGROUND Acute Appendicitis commonest community-acquired intra-abdominal infections. Acute appendicitis and its associated complications are significant source of morbidity and sometimes mortality. The Modified Alvarado Scoring System (MASS has been reported to be a cheap and quick diagnostic tool in patients with acute appendicitis. Diagnostic accuracy have been observed if the scores were applied to various populations and clinical settings. The purpose of this study was to evaluate the diagnostic value of Modified Alvarado Scoring System in patients with acute appendicitis in our setting. The aim of the study is to evaluate the efficacy of the modified Alvarado score as a diagnostic tool in Acute Appendicitis, as the diagnosis of appendicitis depends on the onset of symptoms and the subjective interpretation of the physical examination. MATERIALS AND METHODS This was a prospective study carried out in Pondicherry Institute of Medical Science during the period of November 2013 to May 2015. This study was done on 50 patients diagnosed with Acute Appendicitis and admitted in General Surgery. RESULTS In this study, there were a total of 50 patients who were taken up for surgery based on clinical and radiological diagnosis. Our study demonstrates that modified Alvarado score applied to all adult patients of acute appendicitis in adults with a sensitivity of 60% and a specificity of 40% only. Showing it wasn’t efficient in diagnosing acute appendicitis. The positive predictive value shown by our study was 80% which is marginally lower than that explained in literature which reports 87.5%. Negative appendicectomy rate in this study is 12%. CONCLUSION Alvarado score is a non-invasive, safe diagnostic procedure, which is simple, fast reliable and repeatable; it can be used in all conditions, without expensive and complicated supportive diagnostic methods. Alvarado score increases the diagnostic certainty of clinical examination in diagnosis of

  11. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

    Directory of Open Access Journals (Sweden)

    Helen L Storey

    Full Text Available Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates.

  12. Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes

    Directory of Open Access Journals (Sweden)

    Beng Kwang Ng

    2013-01-01

    Full Text Available Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart. Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6% had ruptured membranes, while 24 patients (11.4% had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (179 of 179, and negative predictive value of 75.0% (24 of 32. By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (146 of 146, and negative predictive value of 36.9% (24 of 65 in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning, the nitrazine test alone or fern test alone.

  13. Usage of Latent Class Analysis in Diagnostic Microbiology in the Absence of Gold Standard Test

    Directory of Open Access Journals (Sweden)

    Gul Bayram Abiha

    2016-12-01

    Full Text Available The evaluation of performance of various tests diagnostic tests in the absence of gold standard is an important problem. Latent class analysis (LCA is a statistical analysis method known for many years, especially in the absence of a gold standard for evaluation of diagnostic tests so that LCA has found its wide application area. During the last decade, LCA method has widely used in for determining sensivity and specifity of different microbiological tests. It has investigated in the diagnosis of mycobacterium tuberculosis, mycobacterium bovis, human papilloma virus, bordetella pertussis, influenza viruses, hepatitis E virus (HEV, hepatitis C virus (HCV and other various viral infections. Researchers have compared several diagnostic tests for the diagnosis of different pathogens with LCA. We aimed to evaluate performance of latent class analysis method used microbiological diagnosis in various diseases in several researches. When we took into account all of these tests' results, we suppose that LCA is a good statistical analysis method to assess different test performances in the absence of gold standard. [Archives Medical Review Journal 2016; 25(4.000: 467-488

  14. A web-based test of residents' skills in diagnostic radiology

    International Nuclear Information System (INIS)

    Finlay, K.; Norman, G.R.; Keane, D.R.; Stolberg, H.

    2006-01-01

    To develop an objective, Web-based tool for evaluating residents' knowledge of diagnostic radiology. We developed and tested a Web-based evaluation tool (the Diagnostic Radiology Skills Test) that consists of 3 tests, one in each of 3 domains of diagnostic radiology: chest, gastrointestinal, and musculoskeletal imaging. Each test comprises 30 cases representing a range of difficulty in the domain, including normal states, normal variants, typical cases of common diagnoses, and cases with more subtle findings. Cases are presented with a long menu of domain-specific possible diagnoses (response options), each coded for diagnostic appropriateness. Our subjects were 21 residents in postgraduate year (PGY) 2 to 5 and 11 experts in diagnostic radiology. Subjects accessed the tool via a Web site on our Web server. Residents test results were compared for reliability and validity across domain, case, and training level. In addition, results were correlated with commonly used established and objective evaluation tools. The tool demonstrated consistent monotonic improvement in performance with training level. It showed acceptable reliability in discriminating between residents at different performance levels, both within and across training levels (r = 0.53 within level and 0.69 across levels). Test results also had concurrent validity against the American College of Radiology In-Training Examination, a widely accepted objective assessment tool (r = 0.65, P < 0.01), and 2 Objective Structured Clinical Examinations (OSCEs) focusing on diagnostic skills (r = 0.78 and r 0.69, P < 0.01, respectively). Our study demonstrates the feasibility of a Web-based, standardized, objective assessment method for evaluating residents' performance. (author)

  15. The diagnostic path, a useful visualisation tool in virtual microscopy

    Directory of Open Access Journals (Sweden)

    Hufnagl Peter

    2006-11-01

    Full Text Available Abstract Background The Virtual Microscopy based on completely digitalised histological slide. Concerning this digitalisation many new features in mircoscopy can be processed by the computer. New applications are possible or old, well known techniques of image analyses can be adapted for routine use. Aims A so called diagnostic path observes in the way of a professional sees through a histological virtual slide combined with the text information of the dictation process. This feature can be used for image retrieval, quality assurance or for educational purpose. Materials and methods The diagnostic path implements a metadata structure of image information. It stores and processes the different images seen by a pathologist during his "slide viewing" and the obtained image sequence ("observation path". Contemporary, the structural details of the pathology reports were analysed. The results were transferred into an XML structure. Based on this structure, a report editor and a search function were implemented. The report editor compiles the "diagnostic path", which is the connection from the image viewing sequence ("observation path" and the oral report sequence of the findings ("dictation path". The time set ups of speech and image viewing serve for the link between the two sequences. The search tool uses the obtained diagnostic path. It allows the user to search for particular histological hallmarks in pathology reports and in the corresponding images. Results The new algorithm was tested on 50 pathology reports and 74 attached histological images. The creation of a new individual diagnostic path is automatically performed during the routine diagnostic process. The test prototype experienced an insignificant prolongation of the diagnosis procedure (oral case description and stated diagnosis by the pathologist and a fast and reliable retrieval, especially useful for continuous education and quality control of case description and diagnostic work

  16. The European Union CREATE project: a model for international standardization of allergy diagnostics and vaccines

    NARCIS (Netherlands)

    Chapman, Martin D.; Ferreira, Fatima; Villalba, Mayte; Cromwell, Oliver; Bryan, Donna; Becker, Wolf-Meinhard; Fernández-Rivas, Montserrat; Durham, Stephen; Vieths, Stefan; van Ree, Ronald; Aalbers, M.; Notten, S.; Ooievaar-de Heer, P.; Ferreira, F.; Gademaier, G.; Wallner, M.; Villalba, M.; Rodriguez, R.; Becker, W.-M.; Eberhardt, F.; Lepp, U.; Raulf-Heimsoth, M.; Valenta, R.; Focke, M.; Bryan, D.; Dolman, C.; Das, R. G.; Vieths, S.; Fötisch, K.; Di Felice, G.; Pini, C.; Cromwell, O.; Fiebig, H.; Weber, B.; van Schijndel, H.; Dorpema, J. W.; Marco, F. M.; Monsalve, R.; Barber, D.; Caldas, E. Fernandez; Moingeon, P.; Didierlaurent, A.; André, C.; Kroon, A.; Neubauer, A.; Chapman, M.; Vailes, L.; Tsay, A.; Durham, S.; Custovic, A.; Simpson, B.; Knulst, A.; Rivas, M. Fernández; Mancebo, E. Gonzalez; Bahima, A. Cistero; Moncin, M. M. San Miguel; Mari, A.; Kinaciyan, T.; Quiralte, J.; Pauli, G.; de Blay, F.; Purohit, A.; Rak, S.

    2008-01-01

    Allergen measurements are used extensively in the formulation of allergy diagnostics and vaccines, yet no purified international allergen standards are available for calibration purposes. The aims of the European Union CREATE project were to develop international standards with verifiable allergen

  17. Quantifying Traces of Tool Use: A Novel Morphometric Analysis of Damage Patterns on Percussive Tools

    OpenAIRE

    Caruana, Matthew V.; Carvalho, Susana; Braun, David R.; Presnyakova, Darya; Haslam, Michael; Archer, Will; Bobe, Rene; Harris, John W. K.

    2014-01-01

    Percussive technology continues to play an increasingly important role in understanding the evolution of tool use. Comparing the archaeological record with extractive foraging behaviors in nonhuman primates has focused on percussive implements as a key to investigating the origins of lithic technology. Despite this, archaeological approaches towards percussive tools have been obscured by a lack of standardized methodologies. Central to this issue have been the use of qualitative, non-diagnost...

  18. Bayesian modeling and inference for diagnostic accuracy and probability of disease based on multiple diagnostic biomarkers with and without a perfect reference standard.

    Science.gov (United States)

    Jafarzadeh, S Reza; Johnson, Wesley O; Gardner, Ian A

    2016-03-15

    The area under the receiver operating characteristic (ROC) curve (AUC) is used as a performance metric for quantitative tests. Although multiple biomarkers may be available for diagnostic or screening purposes, diagnostic accuracy is often assessed individually rather than in combination. In this paper, we consider the interesting problem of combining multiple biomarkers for use in a single diagnostic criterion with the goal of improving the diagnostic accuracy above that of an individual biomarker. The diagnostic criterion created from multiple biomarkers is based on the predictive probability of disease, conditional on given multiple biomarker outcomes. If the computed predictive probability exceeds a specified cutoff, the corresponding subject is allocated as 'diseased'. This defines a standard diagnostic criterion that has its own ROC curve, namely, the combined ROC (cROC). The AUC metric for cROC, namely, the combined AUC (cAUC), is used to compare the predictive criterion based on multiple biomarkers to one based on fewer biomarkers. A multivariate random-effects model is proposed for modeling multiple normally distributed dependent scores. Bayesian methods for estimating ROC curves and corresponding (marginal) AUCs are developed when a perfect reference standard is not available. In addition, cAUCs are computed to compare the accuracy of different combinations of biomarkers for diagnosis. The methods are evaluated using simulations and are applied to data for Johne's disease (paratuberculosis) in cattle. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Computational evaluation of a pencil ionization chamber in a standard diagnostic radiology beam

    International Nuclear Information System (INIS)

    Mendonca, Dalila Souza Costa; Neves, Lucio Pereira; Perini, Ana Paula; Belinato, Walmir

    2016-01-01

    In this work a pencil ionization chamber was evaluated. This evaluation consisted in the determination of the influence of the ionization chamber components in its response. For this purpose, the Monte Carlo simulations and the spectrum of the standard diagnostic radiology beam (RQR5) were utilized. The results obtained, showed that the influence of the ionization chamber components presented no significant influence on the chamber response. Therefore, this ionization chamber is a good alternative for dosimetry in diagnostic radiology. (author)

  20. Feasibility of streamlining an interactive Bayesian-based diagnostic support tool designed for clinical practice

    Science.gov (United States)

    Chen, Po-Hao; Botzolakis, Emmanuel; Mohan, Suyash; Bryan, R. N.; Cook, Tessa

    2016-03-01

    In radiology, diagnostic errors occur either through the failure of detection or incorrect interpretation. Errors are estimated to occur in 30-35% of all exams and contribute to 40-54% of medical malpractice litigations. In this work, we focus on reducing incorrect interpretation of known imaging features. Existing literature categorizes cognitive bias leading a radiologist to an incorrect diagnosis despite having correctly recognized the abnormal imaging features: anchoring bias, framing effect, availability bias, and premature closure. Computational methods make a unique contribution, as they do not exhibit the same cognitive biases as a human. Bayesian networks formalize the diagnostic process. They modify pre-test diagnostic probabilities using clinical and imaging features, arriving at a post-test probability for each possible diagnosis. To translate Bayesian networks to clinical practice, we implemented an entirely web-based open-source software tool. In this tool, the radiologist first selects a network of choice (e.g. basal ganglia). Then, large, clearly labeled buttons displaying salient imaging features are displayed on the screen serving both as a checklist and for input. As the radiologist inputs the value of an extracted imaging feature, the conditional probabilities of each possible diagnosis are updated. The software presents its level of diagnostic discrimination using a Pareto distribution chart, updated with each additional imaging feature. Active collaboration with the clinical radiologist is a feasible approach to software design and leads to design decisions closely coupling the complex mathematics of conditional probability in Bayesian networks with practice.

  1. Chest X-ray : a cost-diagnostic benefit analysis

    International Nuclear Information System (INIS)

    Winter, L.H.L.

    1991-01-01

    Although plain chest radiography is one of the most useful diagnostic tools available to the physician, this procedure has not evolved into a consistent method. Two Large Field of View Image Intensifiers (LFOV-II) became available; the large imaging area makes them suitable for chest imaging. Both modalities supply 100 mm images to the radiologist. In this thesis the 'diagnostic benefits and 'costs' of these modalities are evaluated and related to the 'gold' standard (conventional full-size). The emphasis is on diagnostic image quality using phantoms for observer performance qualities. (author). 170 refs.; 21 figs.; 47 tabs

  2. Diagnostic accuracy of WHO verbal autopsy tool for ascertaining causes of neonatal deaths in the urban setting of Pakistan: a hospital-based prospective study.

    Science.gov (United States)

    Soofi, Sajid Bashir; Ariff, Shabina; Khan, Ubaidullah; Turab, Ali; Khan, Gul Nawaz; Habib, Atif; Sadiq, Kamran; Suhag, Zamir; Bhatti, Zaid; Ahmed, Imran; Bhal, Rajiv; Bhutta, Zulfiqar Ahmed

    2015-10-05

    Globally, clinical certification of the cause of neonatal death is not commonly available in developing countries. Under such circumstances it is imperative to use available WHO verbal autopsy tool to ascertain causes of death for strategic health planning in countries where resources are limited and the burden of neonatal death is high. The study explores the diagnostic accuracy of WHO revised verbal autopsy tool for ascertaining the causes of neonatal deaths against reference standard diagnosis obtained from standardized clinical and supportive hospital data. All neonatal deaths were recruited between August 2006 -February 2008 from two tertiary teaching hospitals in Province Sindh, Pakistan. The reference standard cause of death was established by two senior pediatricians within 2 days of occurrence of death using the International Cause of Death coding system. For verbal autopsy, trained female community health worker interviewed mother or care taker of the deceased within 2-6 weeks of death using a modified WHO verbal autopsy tool. Cause of death was assigned by 2 trained pediatricians. The performance was assessed in terms of sensitivity and specificity. Out of 626 neonatal deaths, cause-specific mortality fractions for neonatal deaths were almost similar in both verbal autopsy and reference standard diagnosis. Sensitivity of verbal autopsy was more than 93% for diagnosing prematurity and 83.5% for birth asphyxia. However the verbal autopsy didn't have acceptable accuracy for diagnosing the congenital malformation 57%. The specificity for all five major causes of neonatal deaths was greater than 90%. The WHO revised verbal autopsy tool had reasonable validity in determining causes of neonatal deaths. The tool can be used in resource limited community-based settings where neonatal mortality rate is high and death certificates from hospitals are not available.

  3. Diagnostics of Pupils' Meta-Subject Competence during Lessons on Mathematics in Secondary Schools

    Science.gov (United States)

    Khuziakhmetova, Anvar N.; Naumova, Marina V.

    2016-01-01

    The relevance of diagnostic meta-subject competence measures in secondary schools is caused by the fact that the importance of a meta-subject competence formation was officially defined in educational standards, but there are still no qualitative and informative diagnostic tools for this competence development. The purpose of the article is to…

  4. Synchrotron radiation from magnetic undulators as a prospective diagnostic tool

    International Nuclear Information System (INIS)

    Barbini, R.; Ciocci, F.; Dattoli, G.; Torre, A.; Ginnessi, L.

    1989-01-01

    The brightness of the radiation emitted by an ultrarelativistic e-beam passing through a magnetic undulator is sensitive to the beam quality (namely, energy spread and emittances) and to the undulator characteristics (i.e., possible random errors both in intensity and direction of magnetization, etc.) The spectrum distortion induced by the above effects and the possibility of using the undulator radiation as a diagnostic tool is discussed. Finally the importance of near-field effects when the radiation is detectedunfocussed off-axis and how they can combine with the effects induced by the beam emittances to produced a larger on-axis inhomogeneous broadening

  5. MicroRNAs: A Puzzling Tool in Cancer Diagnostics and Therapy.

    Science.gov (United States)

    D'Angelo, Barbara; Benedetti, Elisabetta; Cimini, Annamaria; Giordano, Antonio

    2016-11-01

    MicroRNAs (miRNAs) constitute a dominating class of small RNAs that regulate diverse cellular functions. Due the pivotal role of miRNAs in biological processes, a deregulated miRNA expression is likely involved in human cancers. MicroRNAs possess tumor suppressor capability, as well as display oncogenic characteristics. Interestingly, miRNAs exist in various biological fluids as circulating entities. Changes in the profile of circulating miRNAs are indicative of pathophysiological conditions in human cancer. This concept has led to consider circulating miRNAs valid biomarkers in cancer diagnostics. Furthermore, current research promotes the use of miRNAs as a target in cancer therapy. However, miRNAs are an evolving research field. Although miRNAs have been demonstrated to be potentially valuable tools both in cancer diagnosis and treatment, a greater effort should be made to improve our understanding of miRNAs biology. This review describes the biology of microRNAs, emphasizing on the use of miRNAs in cancer diagnostics and therapy. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  6. Depression screening in stroke: a comparison of alternative measures with the structured diagnostic interview for the diagnostic and statistical manual of mental disorders, fourth edition (major depressive episode) as criterion standard.

    Science.gov (United States)

    Turner, Alyna; Hambridge, John; White, Jennifer; Carter, Gregory; Clover, Kerrie; Nelson, Louise; Hackett, Maree

    2012-04-01

    Screening tools for depression and psychological distress commonly used in medical settings have not been well validated in stroke populations. We aimed to determine the accuracy of common screening tools for depression or distress in detecting caseness for a major depressive episode compared with a clinician-administered structured clinical interview for Diagnostic and Statistical Manual of Mental Disorders Fourth Edition as the gold standard. Seventy-two participants ≥3 weeks poststroke underwent a diagnostic interview for major depressive episode and completed the Patient Health Questionnaire-2 and -9, Hospital Anxiety and Depression Scale, Beck Depression Inventory-II, Distress Thermometer, and Kessler-10. Internal consistency, sensitivity, specificity, likelihood ratios, and posttest probabilities were calculated. Each measure was validated against the gold standard using receiver operating characteristic curves with comparison of the area under the curve for all measures. Internal consistency ranged from acceptable to excellent for all measures (Cronbach α=0.78-0.94). Areas under the curve (95% CI) for the Patient Health Questionnaire-2, Patient Health Questionnaire-9, Hospital Anxiety and Depression Scale depression and total score, Beck Depression Inventory-II, and Kessler-10 ranged from 0.80 (0.69-0.89) for the Kessler-10 to 0.89 (0.79-0.95) for the Beck Depression Inventory-II with no significant differences between measures. The Distress Thermometer had an area under the curve (95% CI) of 0.73 (0.61-0.83), significantly smaller than the Beck Depression Inventory-II (P<0.05). Apart from the Distress Thermometer, selected scales performed adequately in a stroke population with no significant difference between measures. The Patient Health Questionnaire-2 would be the most useful single screen given free availability and the shortest number of items.

  7. Re-Establishment of Standard Radiation Qualities for Calibration of Dosemeter in Diagnostic Radiology - RQR Series

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Norhayati Abdullah; Mohd Firdaus Abd Rahman

    2016-01-01

    After repairing the high voltage (HV) generator for Philips MG165 X-Ray Machine, the reestablishment of the standard radiation qualities has been done at Medical Physics Calibration Laboratory to meet the IEC and IAEA standard. Standard radiation qualities are the important criteria for calibration of dosemeter in diagnostic radiology. Standard radiation qualities are defined as the added filtration needed to produce and the half value layer (HVL) of the beam for specifies x-ray tube kilo voltage (kV). For calibration of dosemeter in diagnostic radiology, standard radiation qualities RQR represent the beam incident on the patient in general radiography, fluoroscopy and dental application. The HVL were measured using PTW ion chamber of volume 1 cm"3 with PTW electrometer and aluminium filter with 99.9 % purity was used as additional filter for RQR and filter for HVL. The first establishment of standard radiation qualities was made in 2009 for the radiation qualities of RQR. The results of additional filter and 1st HVL from 2009 to 2016 will be discussed further in paper. The ratios of the measured HVL to the standard IEC HVL value for the RQR series also described in this paper. The details of the measurement and the results are described in this paper. (author)

  8. Applying open source data visualization tools to standard based medical data.

    Science.gov (United States)

    Kopanitsa, Georgy; Taranik, Maxim

    2014-01-01

    Presentation of medical data in personal health records (PHRs) requires flexible platform independent tools to ensure easy access to the information. Different backgrounds of the patients, especially elder people require simple graphical presentation of the data. Data in PHRs can be collected from heterogeneous sources. Application of standard based medical data allows development of generic visualization methods. Focusing on the deployment of Open Source Tools, in this paper we applied Java Script libraries to create data presentations for standard based medical data.

  9. A computational framework for converting textual clinical diagnostic criteria into the quality data model.

    Science.gov (United States)

    Hong, Na; Li, Dingcheng; Yu, Yue; Xiu, Qiongying; Liu, Hongfang; Jiang, Guoqian

    2016-10-01

    Constructing standard and computable clinical diagnostic criteria is an important but challenging research field in the clinical informatics community. The Quality Data Model (QDM) is emerging as a promising information model for standardizing clinical diagnostic criteria. To develop and evaluate automated methods for converting textual clinical diagnostic criteria in a structured format using QDM. We used a clinical Natural Language Processing (NLP) tool known as cTAKES to detect sentences and annotate events in diagnostic criteria. We developed a rule-based approach for assigning the QDM datatype(s) to an individual criterion, whereas we invoked a machine learning algorithm based on the Conditional Random Fields (CRFs) for annotating attributes belonging to each particular QDM datatype. We manually developed an annotated corpus as the gold standard and used standard measures (precision, recall and f-measure) for the performance evaluation. We harvested 267 individual criteria with the datatypes of Symptom and Laboratory Test from 63 textual diagnostic criteria. We manually annotated attributes and values in 142 individual Laboratory Test criteria. The average performance of our rule-based approach was 0.84 of precision, 0.86 of recall, and 0.85 of f-measure; the performance of CRFs-based classification was 0.95 of precision, 0.88 of recall and 0.91 of f-measure. We also implemented a web-based tool that automatically translates textual Laboratory Test criteria into the QDM XML template format. The results indicated that our approaches leveraging cTAKES and CRFs are effective in facilitating diagnostic criteria annotation and classification. Our NLP-based computational framework is a feasible and useful solution in developing diagnostic criteria representation and computerization. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Consensus based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants.

    NARCIS (Netherlands)

    Gardner, I.A.; Nielsen, S.S.; Whittington, R.J.; Collins, M.T.; Bakker, D.; Harris, B.; Sreevatsan, S.; Lombard, J.E.; Sweeney, R.; Smith, D.R.; Gavalchin, J.; Eda, S.

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy studies

  11. New diagnostic and therapeutic tools for tuberculosis using anti-ESAT-6/CFP-10 aptamers

    CSIR Research Space (South Africa)

    Rotherham, L

    2008-11-01

    Full Text Available to form the heterodimer in vitro. The scientists test the ability of the apmaters to: 1) be used as TB diagnostics tools by detecting the presence of ESAT-6 and/or CFP-10 in blood or sputum samples; 2) inhibit the virulence of M. tuberculosis in vitro...

  12. A survey of diagnostic ultrasound within the physiotherapy profession for the design of future training tools

    International Nuclear Information System (INIS)

    McKiernan, Sharmaine; Chiarelli, Pauline; Warren-Forward, Helen

    2011-01-01

    The expansion of diagnostic ultrasound outside of the traditional radiology profession into the physiotherapy profession is occurring. The purpose of this study was to determine if physiotherapists are purchasing diagnostic ultrasound machines, receiving training in the modality and what imaging procedures they are performing. For the design of future training tools, also investigated were the methods of training that physiotherapists might find most beneficial and what content they deem necessary to be covered during such training for the use of diagnostic ultrasound for their profession. An e-mail invitation was sent to physiotherapists throughout Australian who were registered on two databases, asking them to complete a web based survey. The survey was comprised of 18 questions including open and closed items. The data was then categorised into themes in accordance with the purpose of the study. Of the respondents, 39% did not own a diagnostic ultrasound machine, 33% had access to a machine that was owned by their employer and 18% actually owned a machine themselves. Training in diagnostic ultrasound had been received by 61% of the respondents however for 67% of those who had been trained, this training had only lasted for several hours, not days or weeks. For future training in ultrasound the majority of respondents would prefer either a workshop or DVD to cover imaging anatomy, the use of machine controls and scanning the pelvic floor, abdominal muscles and shoulder. From this survey it can be concluded that physiotherapists have an interest in or are using diagnostic ultrasound in their practice. While some form of training is being provided, further training is considered necessary and wanted by the physiotherapists so training tools need to be developed.

  13. A survey of diagnostic ultrasound within the physiotherapy profession for the design of future training tools

    Energy Technology Data Exchange (ETDEWEB)

    McKiernan, Sharmaine, E-mail: sharmaine.mckiernan@newcastle.edu.a [School of Health Sciences, University of Newcastle, Callaghan, NSW (Australia); Chiarelli, Pauline; Warren-Forward, Helen [School of Health Sciences, University of Newcastle, Callaghan, NSW (Australia)

    2011-05-15

    The expansion of diagnostic ultrasound outside of the traditional radiology profession into the physiotherapy profession is occurring. The purpose of this study was to determine if physiotherapists are purchasing diagnostic ultrasound machines, receiving training in the modality and what imaging procedures they are performing. For the design of future training tools, also investigated were the methods of training that physiotherapists might find most beneficial and what content they deem necessary to be covered during such training for the use of diagnostic ultrasound for their profession. An e-mail invitation was sent to physiotherapists throughout Australian who were registered on two databases, asking them to complete a web based survey. The survey was comprised of 18 questions including open and closed items. The data was then categorised into themes in accordance with the purpose of the study. Of the respondents, 39% did not own a diagnostic ultrasound machine, 33% had access to a machine that was owned by their employer and 18% actually owned a machine themselves. Training in diagnostic ultrasound had been received by 61% of the respondents however for 67% of those who had been trained, this training had only lasted for several hours, not days or weeks. For future training in ultrasound the majority of respondents would prefer either a workshop or DVD to cover imaging anatomy, the use of machine controls and scanning the pelvic floor, abdominal muscles and shoulder. From this survey it can be concluded that physiotherapists have an interest in or are using diagnostic ultrasound in their practice. While some form of training is being provided, further training is considered necessary and wanted by the physiotherapists so training tools need to be developed.

  14. Vulnerability analysis of DT fusion diagnostics for laser Megajoule facility. A new tool: Diacad

    International Nuclear Information System (INIS)

    D'hose, C.; Baggio, J.; Musseau, O.

    1999-01-01

    The Megajoule laser (LMJ) project is a major component of the French simulation program to study inertial confinement. This new facility will provide an energy 60 times greater than the largest lasers presently available (Phebus, Nova, Omega). Many diagnostic links will have to be developed in order to acquire complementary knowledge in this domain. A computer based tool has been defined. This paper presents the most recent developments of this new CAD (computer assisted diagnosis) tool. We first describe LMJ context, and then the analysis methodology developed to address the sensitivity to transient radiation of nuclear diagnosis links. This tool takes into account the vulnerability of individual parts and the global structure of the link. (A.C.)

  15. A Diagnostics Tool to detect ensemble forecast system anomaly and guide operational decisions

    Science.gov (United States)

    Park, G. H.; Srivastava, A.; Shrestha, E.; Thiemann, M.; Day, G. N.; Draijer, S.

    2017-12-01

    The hydrologic community is moving toward using ensemble forecasts to take uncertainty into account during the decision-making process. The New York City Department of Environmental Protection (DEP) implements several types of ensemble forecasts in their decision-making process: ensemble products for a statistical model (Hirsch and enhanced Hirsch); the National Weather Service (NWS) Advanced Hydrologic Prediction Service (AHPS) forecasts based on the classical Ensemble Streamflow Prediction (ESP) technique; and the new NWS Hydrologic Ensemble Forecasting Service (HEFS) forecasts. To remove structural error and apply the forecasts to additional forecast points, the DEP post processes both the AHPS and the HEFS forecasts. These ensemble forecasts provide mass quantities of complex data, and drawing conclusions from these forecasts is time-consuming and difficult. The complexity of these forecasts also makes it difficult to identify system failures resulting from poor data, missing forecasts, and server breakdowns. To address these issues, we developed a diagnostic tool that summarizes ensemble forecasts and provides additional information such as historical forecast statistics, forecast skill, and model forcing statistics. This additional information highlights the key information that enables operators to evaluate the forecast in real-time, dynamically interact with the data, and review additional statistics, if needed, to make better decisions. We used Bokeh, a Python interactive visualization library, and a multi-database management system to create this interactive tool. This tool compiles and stores data into HTML pages that allows operators to readily analyze the data with built-in user interaction features. This paper will present a brief description of the ensemble forecasts, forecast verification results, and the intended applications for the diagnostic tool.

  16. Developing a Multi-Dimensional Early Elementary Mathematics Screener and Diagnostic Tool: The Primary Mathematics Assessment.

    Science.gov (United States)

    Brendefur, Jonathan L; Johnson, Evelyn S; Thiede, Keith W; Strother, Sam; Severson, Herb H

    2018-01-01

    There is a critical need to identify primary level students experiencing difficulties in mathematics to provide immediate and targeted instruction that remediates their deficits. However, most early math screening instruments focus only on the concept of number, resulting in inadequate and incomplete information for teachers to design intervention efforts. We propose a mathematics assessment that screens and provides diagnostic information in six domains that are important to building a strong foundation in mathematics. This article describes the conceptual framework and psychometric qualities of a web-based assessment tool, the Primary Math Assessment (PMA). The PMA includes a screener to identify students at risk for poor math outcomes and a diagnostic tool to provide a more in-depth profile of children's specific strengths and weaknesses in mathematics. The PMA allows teachers and school personnel to make better instructional decisions by providing more targeted analyses.

  17. Clinical utility and diagnostic accuracy of palm-held, mini-sized ultrasonocardiographic scanner in congenital heart disease

    Directory of Open Access Journals (Sweden)

    Mao-Hung Lo

    2018-02-01

    Conclusion: The diagnostic sensitivity of palm-held scanner in detecting CHD was very good. Despite both instruments having a high diagnostic score in detecting CHD, standard echocardiography had better quality. Traditional echocardiography is still the standard tool for CHD evaluation. However, the palm-held scanner can support physical examination for initial screening and follow-up, and offer cardiologists an opportunity to visualize and listen to the heart at any time.

  18. Performance study of the primary standard ionization chamber for deployment of the diagnostic radiology qualities

    International Nuclear Information System (INIS)

    Cardoso, Ricardo de Souza; Bossio, Francisco; Quaresma, Daniel da Silva; Peixoto, Jose Guilherme Pereira

    2013-01-01

    Activities radiotherapy, diagnostic radiology and radiation protection, require knowledge of physical and dosimetric parameters, to be applied safely. Aiming to meet demand in Brazil, the National Laboratory of Metrology of Ionising Radiation - LNMRI - is deploying the primary standard for the calibration of secondary standard chambers, used in quality control in hospitals, clinics and industries. (author)

  19. A tool for standardized collector performance calculations including PVT

    DEFF Research Database (Denmark)

    Perers, Bengt; Kovacs, Peter; Olsson, Marcus

    2012-01-01

    A tool for standardized calculation of solar collector performance has been developed in cooperation between SP Technical Research Institute of Sweden, DTU Denmark and SERC Dalarna University. The tool is designed to calculate the annual performance of solar collectors at representative locations...... can be tested and modeled as a thermal collector, when the PV electric part is active with an MPP tracker in operation. The thermal collector parameters from this operation mode are used for the PVT calculations....

  20. Development of a high-temperature diagnostics-while-drilling tool.

    Energy Technology Data Exchange (ETDEWEB)

    Chavira, David J.; Huey, David (Stress Engineering Services, Inc.); Hetmaniak, Chris (Stress Engineering Services, Inc.); Polsky, Yarom; King, Dennis K.; Jacobson, Ronald David; Blankenship, Douglas Alan; Knudsen, Steven Dell; Henfling, Joseph Anthony; Mansure, Arthur James

    2009-01-01

    The envisioned benefits of Diagnostics-While-Drilling (DWD) are based on the principle that high-speed, real-time information from the downhole environment will promote better control of the drilling process. Although in practice a DWD system could provide information related to any aspect of exploration and production of subsurface resources, the current DWD system provides data on drilling dynamics. This particular set of new tools provided by DWD will allow quicker detection of problems, reduce drilling flat-time and facilitate more efficient drilling (drilling optimization) with the overarching result of decreased drilling costs. In addition to providing the driller with an improved, real-time picture of the drilling conditions downhole, data generated from DWD systems provides researchers with valuable, high fidelity data sets necessary for developing and validating enhanced understanding of the drilling process. Toward this end, the availability of DWD creates a synergy with other Sandia Geothermal programs, such as the hard-rock bit program, where the introduction of alternative rock-reduction technologies are contingent on the reduction or elimination of damaging dynamic effects. More detailed descriptions of the rationale for the program and early development efforts are described in more detail by others [SAND2003-2069 and SAND2000-0239]. A first-generation low-temperature (LT) DWD system was fielded in a series of proof-of-concept tests (POC) to validate functionality. Using the LT system, DWD was subsequently used to support a single-laboratory/multiple-partner CRADA (Cooperative Research and Development Agreement) entitled Advanced Drag Bits for Hard-Rock Drilling. The drag-bit CRADA was established between Sandia and four bit companies, and involved testing of a PDC bit from each company [Wise, et al., 2003, 2004] in the same lithologic interval at the Gas Technology Institute (GTI) test facility near Catoosa, OK. In addition, the LT DWD system has

  1. Acquaintance to Artificial Neural Networks and use of artificial intelligence as a diagnostic tool for tuberculosis: A review.

    Science.gov (United States)

    Dande, Payal; Samant, Purva

    2018-01-01

    Tuberculosis [TB] has afflicted numerous nations in the world. As per a report by the World Health Organization [WHO], an estimated 1.4 million TB deaths in 2015 and an additional 0.4 million deaths resulting from TB disease among people living with HIV, were observed. Most of the TB deaths can be prevented if it is detected at an early stage. The existing processes of diagnosis like blood tests or sputum tests are not only tedious but also take a long time for analysis and cannot differentiate between different drug resistant stages of TB. The need to find newer prompt methods for disease detection has been aided by the latest Artificial Intelligence [AI] tools. Artificial Neural Network [ANN] is one of the important tools that is being used widely in diagnosis and evaluation of medical conditions. This review aims at providing brief introduction to various AI tools that are used in TB detection and gives a detailed description about the utilization of ANN as an efficient diagnostic technique. The paper also provides a critical assessment of ANN and the existing techniques for their diagnosis of TB. Researchers and Practitioners in the field are looking forward to use ANN and other upcoming AI tools such as Fuzzy-logic, genetic algorithms and artificial intelligence simulation as a promising current and future technology tools towards tackling the global menace of Tuberculosis. Latest advancements in the diagnostic field include the combined use of ANN with various other AI tools like the Fuzzy-logic, which has led to an increase in the efficacy and specificity of the diagnostic techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Use of Aptamers as Diagnostics Tools and Antiviral Agents for Human Viruses

    Directory of Open Access Journals (Sweden)

    Víctor M. González

    2016-12-01

    Full Text Available Appropriate diagnosis is the key factor for treatment of viral diseases. Time is the most important factor in rapidly developing and epidemiologically dangerous diseases, such as influenza, Ebola and SARS. Chronic viral diseases such as HIV-1 or HCV are asymptomatic or oligosymptomatic and the therapeutic success mainly depends on early detection of the infective agent. Over the last years, aptamer technology has been used in a wide range of diagnostic and therapeutic applications and, concretely, several strategies are currently being explored using aptamers against virus proteins. From a diagnostics point of view, aptamers are being designed as a bio-recognition element in diagnostic systems to detect viral proteins either in the blood (serum or plasma or into infected cells. Another potential use of aptamers is for therapeutics of viral infections, interfering in the interaction between the virus and the host using aptamers targeting host-cell matrix receptors, or attacking the virus intracellularly, targeting proteins implicated in the viral replication cycle. In this paper, we review how aptamers working against viral proteins are discovered, with a focus on recent advances that improve the aptamers’ properties as a real tool for viral infection detection and treatment.

  3. Diagnostic accuracy of organ electrodermal diagnostics | Szopinski ...

    African Journals Online (AJOL)

    Objective. To estimate the diagnostic accuracy as well as the scope of utilisation of a new bio-electronic method of organ diagnostics. Design. Double-blind comparative study of the diagnostic results obtained by means of organ electrodermal diagnostics (OED) and clinical diagnoses, as a criterion standard. Setting.

  4. Evaluation of the accuracy of diagnostic scales for a syndrome in Chinese medicine in the absence of a gold standard.

    Science.gov (United States)

    Wang, Xiao Nan; Zhou, Vanessa; Liu, Qiang; Gao, Ying; Zhou, Xiao-Hua

    2016-01-01

    The concept of syndromes (zhengs) is unique to Chinese medicine (CM) and difficult to measure. Expert consensus is used as a gold standard to identify zhengs and evaluate the accuracy of existing diagnostic scales for zhengs. But, the use of expert consensus as a gold standard is problematic because the diagnosis of zhengs by expert consensus is not 100 % accurate. This study aimed to evaluate the accuracy of standardized diagnostic scales for a syndrome zhengs in the absence of a gold standard, with application to internal wind (nei feng) syndrome in ischemic stroke patients. A total of 204 participants (age 41-84 years) with ischemic stroke were assessed by the stroke syndrome differentiation diagnostic criterion (SSDC), ischemic stroke TCM syndrome diagnostic scale (ISDS), and expert syndrome differentiation (ESD). The diagnostic tests and data collection process were conducted over a 10-month period (February 2008 to November 2008) in 10 hospitals across nine cities in China. The Bayesian method was used to estimate the accuracy of the SSDC, ISDS, and ESD. For internal wind syndrome, the estimated sensitivities and specificities of the SSDC, ISDS, and ESD without use of a gold standard were respectively: [Formula: see text], [Formula: see text]; [Formula: see text], [Formula: see text]; and [Formula: see text], [Formula: see text]. After adjusting for imperfect gold standard bias, we found that both the sensitivity and specificity of the ISDS were higher than those of the SSDC for diagnosis of internal wind syndrome in ischemic stroke patients.

  5. Demise of Polymerase Chain Reaction/Electrospray Ionization-Mass Spectrometry as an Infectious Diseases Diagnostic Tool.

    Science.gov (United States)

    Özenci, Volkan; Patel, Robin; Ullberg, Måns; Strålin, Kristoffer

    2018-01-18

    Although there are several US Food and Drug Administration (FDA)-approved/cleared molecular microbiology diagnostics for direct analysis of patient samples, all are single target or panel-based tests. There is no FDA-approved/cleared diagnostic for broad microbial detection. Polymerase chain reaction (PCR)/electrospray ionization-mass spectrometry (PCR/ESI-MS), commercialized as the IRIDICA system (Abbott) and formerly PLEX-ID, had been under development for over a decade and had become CE-marked and commercially available in Europe in 2014. Capable of detecting a large number of microorganisms, it was under review at the FDA when, in April 2017, Abbott discontinued it. This turn of events represents not only the loss of a potential diagnostic tool for infectious diseases but may be a harbinger of similar situations with other emerging and expensive microbial diagnostics, especially genomic tests. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  6. INCLEN diagnostic tool for attention deficit hyperactivity disorder (INDT-ADHD): development and validation.

    Science.gov (United States)

    Mukherjee, Sharmila; Aneja, Satinder; Russell, Paul S S; Gulati, Sheffali; Deshmukh, Vaishali; Sagar, Rajesh; Silberberg, Donald; Bhutani, Vinod K; Pinto, Jennifer M; Durkin, Maureen; Pandey, Ravindra M; Nair, M K C; Arora, Narendra K

    2014-06-01

    To develop and validate INCLEN Diagnostic Tool for Attention Deficit Hyperactivity Disorder (INDT-ADHD). Diagnostic test evaluation by cross sectional design. Tertiary care pediatric centers. 156 children aged 65-117 months. After randomization, INDT-ADHD and Connors 3 Parent Rating Scale (C3PS) were administered, followed by an expert evaluation by DSM-IV-TR diagnostic criteria. Psychometric evaluation of diagnostic accuracy, validity (construct, criterion and convergent) and internal consistency. INDT-ADHD had 18 items that quantified symptoms and impairment. Attention deficit hyperactivity disorder was identified in 57, 87 and 116 children by expert evaluation, INDT-ADHD and C3PS, respectively. Psychometric parameters of INDT-ADHD for differentiating attention deficit hyperactivity disorder and normal children were: sensitivity 87.7%, specificity 97.2%, positive predictive value 98.0% and negative predictive value 83.3%, whereas for differentiating from other neuro-developmental disorders were 87.7%, 42.9%, 58.1% and 79.4%, respectively. Internal consistency was 0.91. INDT-ADHD has a 4-factor structure explaining 60.4% of the variance. Convergent validity with Conner's Parents Rating Scale was moderate (r =0.73, P= 0.001). INDT-ADHD is suitable for diagnosing attention deficit hyperactivity disorder in Indian children between the ages of 6 to 9 years.

  7. Air kerma standardization for diagnostic radiology, and requirements proposal for calibration laboratories

    International Nuclear Information System (INIS)

    Ramos, Manoel Mattos Oliveira

    2009-01-01

    The demand for calibration services and quality control in diagnostic radiology has grown in the country since the publication of the governmental regulation 453, issued by the Ministry of Health in 1998. At that time, to produce results facing the new legislation, many laboratories used different standards and radiation qualities, some of which could be inadequate. The international standards neither supplied consistent radiation qualities and standardization for the different types of equipment available. This situation changed with the publication of the new edition of the IEC 61267 standard, published in 2005. A metrology network was created, but it is not yet accredited by the accreditation organism of the country, INMETRO. The objective of this work was to implement the standardization of the air kerma for the un attenuated qualities (RQR) of IEC 61267, and to develop a requirement proposal for instruments calibration laboratories. Results of interlaboratory comparisons demonstrate that the quantity is standardized and internationally traceable. A laboratory requirement proposal was finalized and it shall be submitted to INMETRO to be used as auxiliary normative document in laboratory accreditation. (author)

  8. DsixTools: the standard model effective field theory toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Celis, Alejandro [Ludwig-Maximilians-Universitaet Muenchen, Fakultaet fuer Physik, Arnold Sommerfeld Center for Theoretical Physics, Munich (Germany); Fuentes-Martin, Javier; Vicente, Avelino [Universitat de Valencia-CSIC, Instituto de Fisica Corpuscular, Valencia (Spain); Virto, Javier [University of Bern, Albert Einstein Center for Fundamental Physics, Institute for Theoretical Physics, Bern (Switzerland)

    2017-06-15

    We present DsixTools, a Mathematica package for the handling of the dimension-six standard model effective field theory. Among other features, DsixTools allows the user to perform the full one-loop renormalization group evolution of the Wilson coefficients in the Warsaw basis. This is achieved thanks to the SMEFTrunner module, which implements the full one-loop anomalous dimension matrix previously derived in the literature. In addition, DsixTools also contains modules devoted to the matching to the ΔB = ΔS = 1, 2 and ΔB = ΔC = 1 operators of the Weak Effective Theory at the electroweak scale, and their QCD and QED Renormalization group evolution below the electroweak scale. (orig.)

  9. Fluorophotometry as a diagnostic tool for the evaluation of dry eye disease

    Directory of Open Access Journals (Sweden)

    Fan Vincent C

    2006-05-01

    Full Text Available Abstract Background Dry eye disease is a common debilitating ocular disease. Current diagnostic tests used in dry eye disease are often neither sensitive nor reproducible, making it difficult to accurately diagnose and determine end points for clinical trials, or evaluate the usefulness of different medications in the treatment of dry eye disease. The recently developed fluorophotometer can objectively detect changes in the corneal epithelium by quantitatively measuring its barrier function or permeability. The purpose of the study is to investigate the use of corneal fluorescein penetration measured by the fluorophotometer as a diagnostic tool in the evaluation of dry eye patients. Methods Dry eye patients (16 eyes, who presented with a chief complaint of ocular irritation corresponding with dry eye, low Schirmer's one test ( Results Ten minutes after fluorescein installition, patients with dry eye disease averaged a five-fold increase in corneal tissue fluorescein concentration (mean = 375.26 ± 202.67 ng/ml compared with that of normal subjects (mean = 128.19 ± 85.84 ng/ml. Sixty minutes after dye installation, patients with dry eye disease still revealed higher corneal tissue fluorescein concentration (mean = 112.87 ± 52.83 ng/ml compared with that of controls (mean = 40.64 ± 7.96 ng/ml, averaging a three-fold increase. Conclusion Patients with dry eye disease demonstrated an increased corneal permeability and a slower rate of elimination to topically administered fluorescein when measured by the fluorophotometer. This suggests that fluorophotometry may serve as a valuable quantitative and objective tool for the diagnosis of dry eye disease, and in following patients' response to new treatment modalities. Fluorophotometry may serve as an objective non-invasive tool for end-point analysis in clinical trials of new treatments for dry eye disease.

  10. Diagnostic Machine Learning Models for Acute Abdominal Pain: Towards an e-Learning Tool for Medical Students.

    Science.gov (United States)

    Khumrin, Piyapong; Ryan, Anna; Judd, Terry; Verspoor, Karin

    2017-01-01

    Computer-aided learning systems (e-learning systems) can help medical students gain more experience with diagnostic reasoning and decision making. Within this context, providing feedback that matches students' needs (i.e. personalised feedback) is both critical and challenging. In this paper, we describe the development of a machine learning model to support medical students' diagnostic decisions. Machine learning models were trained on 208 clinical cases presenting with abdominal pain, to predict five diagnoses. We assessed which of these models are likely to be most effective for use in an e-learning tool that allows students to interact with a virtual patient. The broader goal is to utilise these models to generate personalised feedback based on the specific patient information requested by students and their active diagnostic hypotheses.

  11. Evaluation of the New DIN Standard for Quality Assurance of Diagnostic Displays - Technical Review DIN 6868-157.

    Science.gov (United States)

    Entz, Kathrin; Sommer, Alexander; Lenzen, Horst

    2018-01-01

    Acceptance and regular constancy tests are necessary to ensure the quality of diagnostic displays. In November 2014, a new standard (DIN 6868-157) was published which defines the test procedure and limiting values. There are several substantial changes compared with the previous standard DIN V 6868-57, i. e. considering the complete image display system including workstation and application software instead of only the displays. Since its publication, the new standard has raised many questions. This technical review aims to show the strengths and weaknesses of the new standard. Positive aspects are the introduction of a limiting value for the illuminance and the extension of the interval for constancy tests from 3 to 6 six months. The daily constancy test on the other hand, raises several problems and should be replaced by a randomized test. Additionally, the medical relevance is critically questioned and an overview of software for the quality assurance will be given.   · Acceptance and constancy tests for diagnostic displays are defined in DIN 6868-157.. · The new standards has positive and negative aspects.. · Randomized tests should be introduced.. · Entz K, Sommer A, Lenzen H. DIN 6868-157: Image Quality Assurance in Diagnostic X-ray Departments - X-ray Ordinance Acceptance and Constancy Test of Image Display Systems in their Environment - Technical Review -. Fortschr Röntgenstr 2018; 190: 51 - 60. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Development and validation of a premature ejaculation diagnostic tool.

    Science.gov (United States)

    Symonds, Tara; Perelman, Michael A; Althof, Stanley; Giuliano, François; Martin, Mona; May, Kathryn; Abraham, Lucy; Crossland, Anna; Morris, Mark

    2007-08-01

    Diagnosis of premature ejaculation (PE) for clinical trial purposes has typically relied on intravaginal ejaculation latency time (IELT) for entry, but this parameter does not capture the multidimensional nature of PE. Therefore, the aim was to develop a brief, multidimensional, psychometrically validated instrument for diagnosing PE status. The questionnaire development involved three stages: (1) Five focus groups and six individual interviews were conducted to develop the content; (2) psychometric validation using three different groups of men; and (3) generation of a scoring system. For psychometric validation/scoring system development, data was collected from (1) men with PE based on clinician diagnosis, using DSM-IV-TR, who also had IELTs or =11 PE. The development and validation of this new PE diagnostic tool has resulted in a new, user-friendly, and brief self-report questionnaire for use in clinical trials to diagnose PE.

  13. The rapid evolution of molecular genetic diagnostics in neuromuscular diseases.

    Science.gov (United States)

    Volk, Alexander E; Kubisch, Christian

    2017-10-01

    The development of massively parallel sequencing (MPS) has revolutionized molecular genetic diagnostics in monogenic disorders. The present review gives a brief overview of different MPS-based approaches used in clinical diagnostics of neuromuscular disorders (NMDs) and highlights their advantages and limitations. MPS-based approaches like gene panel sequencing, (whole) exome sequencing, (whole) genome sequencing, and RNA sequencing have been used to identify the genetic cause in NMDs. Although gene panel sequencing has evolved as a standard test for heterogeneous diseases, it is still debated, mainly because of financial issues and unsolved problems of variant interpretation, whether genome sequencing (and to a lesser extent also exome sequencing) of single patients can already be regarded as routine diagnostics. However, it has been shown that the inclusion of parents and additional family members often leads to a substantial increase in the diagnostic yield in exome-wide/genome-wide MPS approaches. In addition, MPS-based RNA sequencing just enters the research and diagnostic scene. Next-generation sequencing increasingly enables the detection of the genetic cause in highly heterogeneous diseases like NMDs in an efficient and affordable way. Gene panel sequencing and family-based exome sequencing have been proven as potent and cost-efficient diagnostic tools. Although clinical validation and interpretation of genome sequencing is still challenging, diagnostic RNA sequencing represents a promising tool to bypass some hurdles of diagnostics using genomic DNA.

  14. Mass spectrometry based proteomics profiling as diagnostic tool in oncology: current status and future perspective.

    Science.gov (United States)

    Findeisen, Peter; Neumaier, Michael

    2009-01-01

    Proteomics analysis has been heralded as a novel tool for identifying new and specific biomarkers that may improve diagnosis and monitoring of various disease states. Recent years have brought a number of proteomics profiling technologies. Although proteomics profiling has resulted in the detection of disease-associated differences and modification of proteins, current proteomics technologies display certain limitations that are hampering the introduction of these new technologies into clinical laboratory diagnostics and routine applications. In this review, we summarize current advances in mass spectrometry based biomarker discovery. The promises and challenges of this new technology are discussed with particular emphasis on diagnostic perspectives of mass-spectrometry based proteomics profiling for malignant diseases.

  15. The Standard for Clinicians’ Interview in Psychiatry (SCIP): A Clinician-administered Tool with Categorical, Dimensional, and Numeric Output—Conceptual Development, Design, and Description of the SCIP

    Science.gov (United States)

    Nasrallah, Henry; Muvvala, Srinivas; El-Missiry, Ahmed; Mansour, Hader; Hill, Cheryl; Elswick, Daniel; Price, Elizabeth C.

    2016-01-01

    Existing standardized diagnostic interviews (SDIs) were designed for researchers and produce mainly categorical diagnoses. There is an urgent need for a clinician-administered tool that produces dimensional measures, in addition to categorical diagnoses. The Standard for Clinicians’ Interview in Psychiatry (SCIP) is a method of assessment of psychopathology for adults. It is designed to be administered by clinicians and includes the SCIP manual and the SCIP interview. Clinicians use the SCIP questions and rate the responses according to the SCIP manual rules. Clinicians use the patient’s responses to questions, observe the patient’s behaviors and make the final rating of the various signs and symptoms assessed. The SCIP method of psychiatric assessment has three components: 1) the SCIP interview (dimensional) component, 2) the etiological component, and 3) the disorder classification component. The SCIP produces three main categories of clinical data: 1) a diagnostic classification of psychiatric disorders, 2) dimensional scores, and 3) numeric data. The SCIP provides diagnoses consistent with criteria from editions of the Diagnostic and Statistical Manual (DSM) and International Classification of Disease (ICD). The SCIP produces 18 dimensional measures for key psychiatric signs or symptoms: anxiety, posttraumatic stress, obsessions, compulsions, depression, mania, suicidality, suicidal behavior, delusions, hallucinations, agitation, disorganized behavior, negativity, catatonia, alcohol addiction, drug addiction, attention, and hyperactivity. The SCIP produces numeric severity data for use in either clinical care or research. The SCIP was shown to be a valid and reliable assessment tool, and the validity and reliability results were published in 2014 and 2015. The SCIP is compatible with personalized psychiatry research and is in line with the Research Domain Criteria framework. PMID:27800284

  16. Development and Validation of a Standardized Tool for Prioritization of Information Sources.

    Science.gov (United States)

    Akwar, Holy; Kloeze, Harold; Mukhi, Shamir

    2016-01-01

    To validate the utility and effectiveness of a standardized tool for prioritization of information sources for early detection of diseases. The tool was developed with input from diverse public health experts garnered through survey. Ten raters used the tool to evaluate ten information sources and reliability among raters was computed. The Proc mixed procedure with random effect statement and SAS Macros were used to compute multiple raters' Fleiss Kappa agreement and Kendall's Coefficient of Concordance. Ten disparate information sources evaluated obtained the following composite scores: ProMed 91%; WAHID 90%; Eurosurv 87%; MediSys 85%; SciDaily 84%; EurekAl 83%; CSHB 78%; GermTrax 75%; Google 74%; and CBC 70%. A Fleiss Kappa agreement of 50.7% was obtained for ten information sources and 72.5% for a sub-set of five sources rated, which is substantial agreement validating the utility and effectiveness of the tool. This study validated the utility and effectiveness of a standardized criteria tool developed to prioritize information sources. The new tool was used to identify five information sources suited for use by the KIWI system in the CEZD-IIR project to improve surveillance of infectious diseases. The tool can be generalized to situations when prioritization of numerous information sources is necessary.

  17. GPLS VME Module: A Diagnostic and Display Tool for NSLS Micro Systems

    International Nuclear Information System (INIS)

    Ramamoorthy, S.; Smith, J. D.

    1999-01-01

    The General Purpose Light Source VME module is an integral part of every front-end micro in the NSLS control system. The board incorporates features such as a video character generator, clock signals, time-of-day clock, a VME bus interrupter and general-purpose digital inputs and outputs. This module serves as a valuable diagnostic and real-time display tool for the micro development as well as for the find operational systems. This paper describes the functions provided by the board for the NSLS micro control monitor software

  18. Comprehensive Clinical Audits of Diagnostic Radiology Practices: A Tool for Quality Improvement. Quality Assurance Audit for Diagnostic Radiology Improvement and Learning (QUAADRIL)

    International Nuclear Information System (INIS)

    2011-01-01

    Interest in quality assurance processes and quality improvement in diagnostic radiology is being driven by a number of factors. These include the high cost and complexity of radiological equipment, acknowledgement of the possibility of increasing doses to patients, and the importance of radiological diagnosis to patient management within the health care environment. To acknowledge these interests, clinical audits have been introduced and, in Europe, mandated under a European Directive (Council Directive 97/47/EURATOM). Comprehensive clinical audits focus on clinical management and infrastructure, patient related and technical procedures, and education and research. This publication includes a structured set of standards appropriate for diagnostic radiology, an audit guide to their clinical review, and data collection sheets for the rapid production of reports in audit situations. It will be a useful guide for diagnostic radiology facilities wishing to improve their service to patients through timely diagnosis with minimal radiation dose.

  19. Comprehensive Clinical Audits of Diagnostic Radiology Practices: A Tool for Quality Improvement. Quality Assurance Audit for Diagnostic Radiology Improvement and Learning (QUAADRIL)

    International Nuclear Information System (INIS)

    2010-01-01

    Interest in quality assurance processes and quality improvement in diagnostic radiology is being driven by a number of factors. These include the high cost and complexity of radiological equipment, acknowledgement of the possibility of increasing doses to patients, and the importance of radiological diagnosis to patient management within the health care environment. To acknowledge these interests, clinical audits have been introduced and, in Europe, mandated under a European Directive (Council Directive 97/47/EURATOM). Comprehensive clinical audits focus on clinical management and infrastructure, patient related and technical procedures, and education and research. This publication includes a structured set of standards appropriate for diagnostic radiology, an audit guide to their clinical review, and data collection sheets for the rapid production of reports in audit situations. It will be a useful guide for diagnostic radiology facilities wishing to improve their service to patients through timely diagnosis with minimal radiation dose.

  20. Tools for surveying and improving the quality of life: people with special needs in focus.

    Science.gov (United States)

    Hoyningen-Süess, Ursula; Oberholzer, David; Stalder, René; Brügger, Urs

    2012-01-01

    This article seeks to describe online tools for surveying and improving quality of life for people with disabilities living in assisted living centers and special education service organizations. Ensuring a decent quality of life for disabled people is an important welfare state goal. Using well-accepted quality of life conceptions, online diagnostic and planning tools were developed during an Institute for Education, University of Zurich, research project. The diagnostic tools measure, evaluate and analyze disabled people's quality of life. The planning tools identify factors that can affect their quality of life and suggest improvements. Instrument validity and reliability are not tested according to the standard statistical procedures. This will be done at a more advanced stage of the project. Instead, the tool is developed, refined and adjusted in cooperation with practitioners who are constantly judging it according to best practice standards. The tools support staff in assisted living centers and special education service organizations. These tools offer comprehensive resources for surveying, quantifying, evaluating, describing and simulating quality of life elements.

  1. Design standards for experimental and field studies to evaluate diagnostic accuracy of tests for infectious diseases in aquatic animals.

    Science.gov (United States)

    Laurin, E; Thakur, K K; Gardner, I A; Hick, P; Moody, N J G; Crane, M S J; Ernst, I

    2018-05-01

    Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial-animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk-of-failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta-analyses of DAS research literature. © 2018 John Wiley & Sons Ltd.

  2. Model-based evaluation of the use of polycyclic aromatic hydrocarbons molecular diagnostic ratios as a source identification tool

    International Nuclear Information System (INIS)

    Katsoyiannis, Athanasios; Breivik, Knut

    2014-01-01

    Polycyclic Aromatic Hydrocarbons (PAHs) molecular diagnostic ratios (MDRs) are unitless concentration ratios of pair-PAHs with the same molecular weight (MW); MDRs have long been used as a tool for PAHs source identification purposes. In the present paper, the efficiency of the MDR methodology is evaluated through the use of a multimedia fate model, the calculation of characteristic travel distances (CTD) and the estimation of air concentrations for individual PAHs as a function of distance from an initial point source. The results show that PAHs with the same MW are sometimes characterized by substantially different CTDs and therefore their air concentrations and hence MDRs are predicted to change as the distance from the original source increases. From the assessed pair-PAHs, the biggest CTD difference is seen for Fluoranthene (107 km) vs. Pyrene (26 km). This study provides a strong indication that MDRs are of limited use as a source identification tool. -- Highlights: • Model-based evaluation of the PAHs molecular diagnostic ratios efficiency. • Individual PAHs are characterized by different characteristic travel distances. • MDRs are proven to be a limited tool for source identification. • Use of MDRs for other environmental media is likely unfeasible. -- PAHs molecular diagnostic ratios which change greatly as a function of distance from the emitting source are improper for source identification purposes

  3. COMPREHENSIVE DIAGNOSTIC AND IMPROVEMENT TOOLS FOR HVAC-SYSTEM INSTALLATIONS IN LIGHT COMMERCIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Abram Conant; Mark Modera; Joe Pira; John Proctor; Mike Gebbie

    2004-10-31

    Proctor Engineering Group, Ltd. (PEG) and Carrier-Aeroseal LLP performed an investigation of opportunities for improving air conditioning and heating system performance in existing light commercial buildings. Comprehensive diagnostic and improvement tools were created to address equipment performance parameters (including airflow, refrigerant charge, and economizer operation), duct-system performance (including duct leakage, zonal flows and thermal-energy delivery), and combustion appliance safety within these buildings. This investigation, sponsored by the National Energy Technology Laboratory, a division of the U.S. Department of Energy, involved collaboration between PEG and Aeroseal in order to refine three technologies previously developed for the residential market: (1) an aerosol-based duct sealing technology that allows the ducts to be sealed remotely (i.e., without removing the ceiling tiles), (2) a computer-driven diagnostic and improvement-tracking tool for residential duct installations, and (3) an integrated diagnosis verification and customer satisfaction system utilizing a combined computer/human expert system for HVAC performance. Prior to this work the aerosol-sealing technology was virtually untested in the light commercial sector--mostly because the savings potential and practicality of this or any other type of duct sealing had not been documented. Based upon the field experiences of PEG and Aeroseal, the overall product was tailored to suit the skill sets of typical HVAC-contractor personnel.

  4. Consensus-based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants

    DEFF Research Database (Denmark)

    Gardner, Ian A.; Nielsen, Søren Saxmose; Whittington, Richard

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy...... studies and the finding that incomplete or absent reporting of items in the STARD checklist was associated with overly optimistic estimates of test performance characteristics. Although STARD principles apply broadly, specific guidelines do not exist to account for unique considerations in livestock...... for Reporting of Animal Diagnostic Accuracy Studies for paratuberculosis), should facilitate improved quality of reporting of the design, conduct and results of paratuberculosis test accuracy studies which were identified as “poor” in a review published in 2008 in Veterinary Microbiology...

  5. Lung ultrasound as a diagnostic tool for radiographically-confirmed pneumonia in low resource settings.

    Science.gov (United States)

    Ellington, Laura E; Gilman, Robert H; Chavez, Miguel A; Pervaiz, Farhan; Marin-Concha, Julio; Compen-Chang, Patricia; Riedel, Stefan; Rodriguez, Shalim J; Gaydos, Charlotte; Hardick, Justin; Tielsch, James M; Steinhoff, Mark; Benson, Jane; May, Evelyn A; Figueroa-Quintanilla, Dante; Checkley, William

    2017-07-01

    Pneumonia is a leading cause of morbidity and mortality in children worldwide; however, its diagnosis can be challenging, especially in settings where skilled clinicians or standard imaging are unavailable. We sought to determine the diagnostic accuracy of lung ultrasound when compared to radiographically-confirmed clinical pediatric pneumonia. Between January 2012 and September 2013, we consecutively enrolled children aged 2-59 months with primary respiratory complaints at the outpatient clinics, emergency department, and inpatient wards of the Instituto Nacional de Salud del Niño in Lima, Peru. All participants underwent clinical evaluation by a pediatrician and lung ultrasonography by one of three general practitioners. We also consecutively enrolled children without respiratory symptoms. Children with respiratory symptoms had a chest radiograph. We obtained ancillary laboratory testing in a subset. Final clinical diagnoses included 453 children with pneumonia, 133 with asthma, 103 with bronchiolitis, and 143 with upper respiratory infections. In total, CXR confirmed the diagnosis in 191 (42%) of 453 children with clinical pneumonia. A consolidation on lung ultrasound, which is our primary endpoint for pneumonia, had a sensitivity of 88.5%, specificity of 100%, and an area under-the-curve of 0.94 (95% CI 0.92-0.97) when compared to radiographically-confirmed clinical pneumonia. When any abnormality on lung ultrasound was compared to radiographically-confirmed clinical pneumonia the sensitivity increased to 92.2% and the specificity decreased to 95.2%, with an area under-the-curve of 0.94 (95% CI 0.91-0.96). Lung ultrasound had high diagnostic accuracy for the diagnosis of radiographically-confirmed pneumonia. Added benefits of lung ultrasound include rapid testing and high inter-rater agreement. Lung ultrasound may serve as an alternative tool for the diagnosis of pediatric pneumonia. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights

  6. Diagnosis of TIA (DOT) score--design and validation of a new clinical diagnostic tool for transient ischaemic attack.

    Science.gov (United States)

    Dutta, Dipankar

    2016-02-09

    The diagnosis of Transient Ischaemic Attack (TIA) can be difficult and 50-60% of patients seen in TIA clinics turn out to be mimics. Many of these mimics have high ABCD2 scores and fill urgent TIA clinic slots inappropriately. A TIA diagnostic tool may help non-specialists make the diagnosis with greater accuracy and improve TIA clinic triage. The only available diagnostic score (Dawson et al) is limited in scope and not widely used. The Diagnosis of TIA (DOT) Score is a new and internally validated web and mobile app based diagnostic tool which encompasses both brain and retinal TIA. The score was derived retrospectively from a single centre TIA clinic database using stepwise logistic regression by backwards elimination to find the best model. An optimum cutpoint was obtained for the score. The derivation and validation cohorts were separate samples drawn from the years 2010/12 and 2013 respectively. Receiver Operating Characteristic (ROC) curves and area under the curve (AUC) were calculated and the diagnostic accuracy of DOT was compared to the Dawson score. A web and smartphone calculator were designed subsequently. The derivation cohort had 879 patients and the validation cohort 525. The final model had seventeen predictors and had an AUC of 0.91 (95% CI: 0.89-0.93). When tested on the validation cohort, the AUC for DOTS was 0.89 (0.86-0.92) while that of the Dawson score was 0.77 (0.73-0.81). The sensitivity and specificity of the DOT score were 89% (CI: 84%-93%) and 76% (70%-81%) respectively while those of the Dawson score were 83% (78%-88%) and 51% (45%-57%). Other diagnostic accuracy measures (DOT vs. Dawson) include positive predictive values (75% vs. 58%), negative predictive values (89% vs. 79%), positive likelihood ratios (3.67 vs. 1.70) and negative likelihood ratios (0.15 vs. 0.32). The DOT score shows promise as a diagnostic tool for TIA and requires independent external validation before it can be widely used. It could potentially improve the

  7. LEARNING TOOLS INTEROPERABILITY – A NEW STANDARD FOR INTEGRATION OF DISTANCE LEARNING PLATFORMS

    Directory of Open Access Journals (Sweden)

    Oleksandr A. Shcherbyna

    2015-06-01

    Full Text Available For information technology in education there is always an issue of re-usage of electronic educational resources, their transferring possibility from one virtual learning environment to another. Previously, standardized sets of files were used to serve this purpose, for example, SCORM-packages. In this article the new standard Learning Tools Interoperability (LTI is reviewed, which allows users from one environment to access resources from another environment. This makes it possible to integrate them into a single distributed learning environment that is created and shared. The article gives examples of the practical use of standard LTI in Moodle learning management system using External tool and LTI provider plugins.

  8. Role of teleradiology in modern diagnostic imaging

    International Nuclear Information System (INIS)

    Chrzan, R.; Urbanik, A.; Wyrobek -Renczynska, M.; Podsiadlo, L.

    2004-01-01

    Teleradiology is a dynamically expanding technology of electronic transmission of radiologic images. History of teleradiology development, methods of obtaining images in digital form, media used for their transmission, factors affecting time of transmission, methods of visualization of transmitted images, attempts at standardization of new technology and at last typical applications of teleradiology were presented. Teleradiology from the position of technical curiosity advanced to the role of everyday work tool. Possibility of specialist diagnostic imaging assurance in poorly developed regions, not possessing sufficient number of radiologists, turned out particularly important. Cooperation of regional hospitals with specialist centers of diagnostic images reporting and archiving created a chance for making better use of owned equipment and reducing the costs of diagnostics. For the sake of broader and broader access to teleradiology not only over the world but also in Poland it is advisable to familiarize with its possibilities by both radiologists and clinicists using the results of diagnostic imaging. (author)

  9. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    Science.gov (United States)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  10. The development of standard operating protocols for paediatric radiology

    International Nuclear Information System (INIS)

    Hardwick, J.; Mencik, C.; McLaren, C.; Young, C.; Scadden, S.; Mashford, P.; McHugh, K.; Beckett, M.; Calvert, M.; Marsden, P.J.

    2001-01-01

    This paper describes how the requirement for operating protocols for standard radiological practice was expanded to provide a comprehensive aide to the operator conducting a medical exposure. The protocols adopted now include justification criteria, patient preparation, radiographic technique, standard exposure charts, diagnostic reference levels and image quality criteria. In total, the protocols have been welcomed as a tool for ensuring that medical exposures are properly optimised. (author)

  11. MALDI TOF imaging mass spectrometry in clinical pathology: a valuable tool for cancer diagnostics (review).

    Science.gov (United States)

    Kriegsmann, Jörg; Kriegsmann, Mark; Casadonte, Rita

    2015-03-01

    Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) imaging mass spectrometry (IMS) is an evolving technique in cancer diagnostics and combines the advantages of mass spectrometry (proteomics), detection of numerous molecules, and spatial resolution in histological tissue sections and cytological preparations. This method allows the detection of proteins, peptides, lipids, carbohydrates or glycoconjugates and small molecules.Formalin-fixed paraffin-embedded tissue can also be investigated by IMS, thus, this method seems to be an ideal tool for cancer diagnostics and biomarker discovery. It may add information to the identification of tumor margins and tumor heterogeneity. The technique allows tumor typing, especially identification of the tumor of origin in metastatic tissue, as well as grading and may provide prognostic information. IMS is a valuable method for the identification of biomarkers and can complement histology, immunohistology and molecular pathology in various fields of histopathological diagnostics, especially with regard to identification and grading of tumors.

  12. Job Grading Standard for Machine Tool Operator, WG-3431.

    Science.gov (United States)

    Civil Service Commission, Washington, DC. Bureau of Policies and Standards.

    The standard covers nonsupervisory work involved in the set up, adjustment, and operation of conventional machine tools to perform machining operations in the manufacture and repair of castings, forgings, or parts from raw stock made of various metals, metal alloys, and other materials. A general description of the job at both the WG-8 and WG-9…

  13. A comparison of standard radiological examinations, computed tomography, scintigraphy and angiography in the recidivistic diagnostic of bone tumors

    International Nuclear Information System (INIS)

    Schaeffer, G.

    1986-01-01

    In a retrospective study the diagnostic efficiency of standard radiography, computed tomography (CT), bone scintigraphy and angiography in the diagnosis of tumor recidivism was studied using 54 patients with an operatively treated bone tumor. The highest diagnostic sensitivity (100%) was achieved with the help of CT. For the determination or exclusion of a recidivistic bone tumor, the diagnostic strength of the individual procedures lies in their combinations, but these combinations should be made on the basis of the tumor type and disease. (MBC) [de

  14. New bone post-processing tools in forensic imaging: a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment.

    Science.gov (United States)

    Glemser, Philip A; Pfleiderer, Michael; Heger, Anna; Tremper, Jan; Krauskopf, Astrid; Schlemmer, Heinz-Peter; Yen, Kathrin; Simons, David

    2017-03-01

    The aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy. Thirty autopsy cases (20 with and 10 without rib fractures in autopsy) were randomly selected and included in this study. All cases received a native whole body CT scan prior to the autopsy procedure, which included dissection and careful evaluation of each rib. In addition to standard transverse sections (modality A), CT images were subjected to a reconstruction algorithm to compute axial labelling of the ribs (modality B) as well as "unfolding" visualizations of the rib cage (modality C, "eagle tool"). Three radiologists with different clinical and forensic experience who were blinded to autopsy results evaluated all cases in a random manner of modality and case. Rib fracture assessment of each reader was evaluated compared to autopsy and a CT consensus read as radiologic reference. A detailed evaluation of relevant test parameters revealed a better accordance to the CT consensus read as to the autopsy. Modality C was the significantly quickest rib fracture detection modality despite slightly reduced statistic test parameters compared to modalities A and B. Modern CT post-processing software is able to shorten reading time and to increase sensitivity and specificity compared to standard autopsy alone. The eagle tool as an easy to use tool is suited for an initial rib fracture screening prior to autopsy and can therefore be beneficial for forensic pathologists.

  15. Line and continuum spectroscopy as diagnostic tools for gamma ray bursts

    International Nuclear Information System (INIS)

    Liang, E.P.

    1990-12-01

    We review the theoretical framework of both line and continuum spectra formation in gamma ray bursts. These include the cyclotron features at 10's of keV, redshifted annihilation features at ∼400 keV, as well as other potentially detectable nuclear transition lines, atomic x-ray lines, proton cyclotron lines and plasma oscillation lines. By combining the parameters derived from line and continuum modeling we can try to reconstruct the location, geometry and physical conditions of the burst emission region, thereby constraining and discriminating the astrophysical models. Hence spectroscopy with current and future generations of detectors should provide powerful diagnostic tools for gamma ray bursters. 48 refs., 10 figs., 4 tabs

  16. Managing uncertainty: a qualitative study of GPs' views on the diagnosis and immediate management of transient ischaemic attack and the potential of a diagnostic tool.

    Science.gov (United States)

    Bose, Priyanka; Tarrant, Carolyn; Mistri, Amit K; Wilson, Andrew

    2018-04-12

    Most patients with transient ischaemic attack (TIA) present to their GP. Early identification and treatment reduces the risk of subsequent stroke and consequent disability and mortality. To explore GPs' views on the diagnosis and immediate management of suspected TIA, and the potential utility of a diagnostic tool. This is a qualitative interview study based in Leicestershire, UK. A purposive sample of 10 GPs participated in 30-minute semi-structured telephone interviews. Data were analysed thematically. GPs reported that TIA was more likely to be suspected when patients were more obvious candidates for TIA based on their history, characteristics and symptom presentation. Referrals were in part a strategy to manage risk under conditions of uncertainty and to seek reassurance. GPs valued using a TIA risk stratification tool but felt this did not inform their diagnostic decision making. A diagnostic tool for TIA in primary care was seen to have potential to improve the decision-making process about diagnosis and management and enhance confidence of GPs, particularly in ruling out TIAs. GPs saw benefits of using hard thresholds, but remained concerned about missing TIAs and saw a tool as an adjunct to clinical judgement. GPs weigh up the likelihood of TIA in the context of assessments of candidacy and diverse, often vague, symptoms. A diagnostic tool could support GPs in this process and help reduce reliance on referrals to TIA clinics for reassurance, provided the tool was designed to support decision making in cases of less 'typical' presentations.

  17. Analysis Tools for the Ion Cyclotron Emission Diagnostic on DIII-D

    Science.gov (United States)

    Del Castillo, C. A.; Thome, K. E.; Pinsker, R. I.; Meneghini, O.; Pace, D. C.

    2017-10-01

    Ion cyclotron emission (ICE) waves are excited by suprathermal particles such as neutral beam particles and fusion products. An ICE diagnostic is in consideration for use at ITER, where it could provide important passive measurement of fast ions location and losses, which are otherwise difficult to determine. Simple ICE data analysis codes had previously been developed, but more sophisticated codes are required to facilitate data analysis. Several terabytes of ICE data were collected on DIII-D during the 2015-2017 campaign. The ICE diagnostic consists of antenna straps and dedicated magnetic probes that are both digitized at 200 MHz. A suite of Python spectral analysis tools within the OMFIT framework is under development to perform the memory-intensive analysis of this data. A fast and optimized analysis allows ready access to data visualizations as spectrograms and as plots of both frequency and time cuts of the data. A database of processed ICE data is being constructed to understand the relationship between the frequency and intensity of ICE and a variety of experimental parameters including neutral beam power and geometry, local and global plasma parameters, magnetic fields, and many others. Work supported in part by US DoE under the Science Undergraduate Laboratory Internship (SULI) program and under DE-FC02-04ER54698.

  18. Standardized evaluation of accident victims: demands on diagnostic trauma

    International Nuclear Information System (INIS)

    Kanz, K.G.; Mutschler, W.; Linsenmaier, U.; Pfeifer, K.J.

    2002-01-01

    Introduction. Evaluation of trauma systems requires a complete and exact injury classification. The purpose of this study was the introduction of the Abbreviated injury scale (AIS) for radiological trauma scoring. The development of these easy to use coding tools is essential for prompt quality management of trauma.Material and methods. Standardized radiological injury description using a modified Abbreviated injury scale in combination with a Microsoft Excel trademark spreadsheet allows an immediate calculation of the probability of survival according to TRISS methodology.Results. Computed tomography is the main instrument for injury scoring in trauma care. Postmortem scanning provides a direct feedback for trauma teams especially in cases when autopsy is not possible.Conclusion. Computed tomography enables in combination with a standardized injury description exact trauma scoring. Quality management of trauma care depends on a valid and reliable calculation of the probability of survival using TRISS. (orig.) [de

  19. A malaria diagnostic tool based on computer vision screening and visualization of Plasmodium falciparum candidate areas in digitized blood smears.

    Directory of Open Access Journals (Sweden)

    Nina Linder

    Full Text Available INTRODUCTION: Microscopy is the gold standard for diagnosis of malaria, however, manual evaluation of blood films is highly dependent on skilled personnel in a time-consuming, error-prone and repetitive process. In this study we propose a method using computer vision detection and visualization of only the diagnostically most relevant sample regions in digitized blood smears. METHODS: Giemsa-stained thin blood films with P. falciparum ring-stage trophozoites (n = 27 and uninfected controls (n = 20 were digitally scanned with an oil immersion objective (0.1 µm/pixel to capture approximately 50,000 erythrocytes per sample. Parasite candidate regions were identified based on color and object size, followed by extraction of image features (local binary patterns, local contrast and Scale-invariant feature transform descriptors used as input to a support vector machine classifier. The classifier was trained on digital slides from ten patients and validated on six samples. RESULTS: The diagnostic accuracy was tested on 31 samples (19 infected and 12 controls. From each digitized area of a blood smear, a panel with the 128 most probable parasite candidate regions was generated. Two expert microscopists were asked to visually inspect the panel on a tablet computer and to judge whether the patient was infected with P. falciparum. The method achieved a diagnostic sensitivity and specificity of 95% and 100% as well as 90% and 100% for the two readers respectively using the diagnostic tool. Parasitemia was separately calculated by the automated system and the correlation coefficient between manual and automated parasitemia counts was 0.97. CONCLUSION: We developed a decision support system for detecting malaria parasites using a computer vision algorithm combined with visualization of sample areas with the highest probability of malaria infection. The system provides a novel method for blood smear screening with a significantly reduced need for

  20. SED-ML web tools: generate, modify and export standard-compliant simulation studies.

    Science.gov (United States)

    Bergmann, Frank T; Nickerson, David; Waltemath, Dagmar; Scharm, Martin

    2017-04-15

    The Simulation Experiment Description Markup Language (SED-ML) is a standardized format for exchanging simulation studies independently of software tools. We present the SED-ML Web Tools, an online application for creating, editing, simulating and validating SED-ML documents. The Web Tools implement all current SED-ML specifications and, thus, support complex modifications and co-simulation of models in SBML and CellML formats. Ultimately, the Web Tools lower the bar on working with SED-ML documents and help users create valid simulation descriptions. http://sysbioapps.dyndns.org/SED-ML_Web_Tools/ . fbergman@caltech.edu . © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  1. Web-based tools for quality assurance and radiation protection in diagnostic radiology.

    Science.gov (United States)

    Moores, B M; Charnock, P; Ward, M

    2010-01-01

    Practical and philosophical aspects of radiation protection in diagnostic radiology have changed very little over the past 50 y even though patient doses have continued to rise significantly in this period. This rise has been driven by technological developments, such as multi-slice computed tomography, that have been able to improve diagnostic accuracy but not necessarily provide the same level of risk-benefit to all patients or groups of patients given the dose levels involved. Can practical radiation protection strategies hope to keep abreast of these ongoing developments? A project was started in 1992 in Liverpool that aimed to develop IT driven quality assurance (QA)/radiation protection software tools based upon a modular quality assurance dose data system. One of the modules involved the assessment of the patient entrance surface air kerma (ESAK) for an X-ray examination that was based upon the use of calibrated X-ray tube exposure factors to calculate ESAK as well as collecting appropriate patient details (age, sex, weight, thickness etc). The package also contained modules for logging all necessary equipment performance QA data. This paper will outline the experience gained with this system through its transition from a local application on a stand alone PC within the department to the current web-based approach. Advantages of a web-based approach to delivering such an application as well as centrally storing data originating on many hospital sites will be discussed together with the scientific support processes that can be developed with such a system. This will include local, national and international considerations. The advantages of importing radiographic examination details directly from other electronic storage systems such as a hospital's radiology information system will be presented together with practical outcomes already achieved. This will include the application of statistical techniques to the very large data sets generated. The development

  2. Web-based tools for quality assurance and radiation protection in diagnostic radiology

    International Nuclear Information System (INIS)

    Moores, B. M.; Charnock, P.; Ward, M.

    2010-01-01

    Practical and philosophical aspects of radiation protection in diagnostic radiology have changed very little over the past 50 y even though patient doses have continued to rise significantly in this period. This rise has been driven by technological developments, such as multi-slice computed tomography, that have been able to improve diagnostic accuracy but not necessarily provide the same level of risk-benefit to all patients or groups of patients given the dose levels involved. Can practical radiation protection strategies hope to keep abreast of these ongoing developments? A project was started in 1992 in Liverpool that aimed to develop IT driven quality assurance (QA)/radiation protection software tools based upon a modular quality assurance dose data system. One of the modules involved the assessment of the patient entrance surface air kerma (ESAK) for an X-ray examination that was based upon the use of calibrated X-ray tube exposure factors to calculate ESAK as well as collecting appropriate patient details (age, sex, weight, thickness etc). The package also contained modules for logging all necessary equipment performance QA data. This paper will outline the experience gained with this system through its transition from a local application on a stand alone PC within the department to the current web-based approach. Advantages of a web-based approach to delivering such an application as well as centrally storing data originating on many hospital sites will be discussed together with the scientific support processes that can be developed with such a system. This will include local, national and international considerations. The advantages of importing radiographic examination details directly from other electronic storage systems such as a hospital's radiology information system will be presented together with practical outcomes already achieved. This will include the application of statistical techniques to the very large data sets generated. The development

  3. A Student Assessment Tool for Standardized Patient Simulations (SAT-SPS): Psychometric analysis.

    Science.gov (United States)

    Castro-Yuste, Cristina; García-Cabanillas, María José; Rodríguez-Cornejo, María Jesús; Carnicer-Fuentes, Concepción; Paloma-Castro, Olga; Moreno-Corral, Luis Javier

    2018-05-01

    The evaluation of the level of clinical competence acquired by the student is a complex process that must meet various requirements to ensure its quality. The psychometric analysis of the data collected by the assessment tools used is a fundamental aspect to guarantee the student's competence level. To conduct a psychometric analysis of an instrument which assesses clinical competence in nursing students at simulation stations with standardized patients in OSCE-format tests. The construct of clinical competence was operationalized as a set of observable and measurable behaviors, measured by the newly-created Student Assessment Tool for Standardized Patient Simulations (SAT-SPS), which was comprised of 27 items. The categories assigned to the items were 'incorrect or not performed' (0), 'acceptable' (1), and 'correct' (2). 499 nursing students. Data were collected by two independent observers during the assessment of the students' performance at a four-station OSCE with standardized patients. Descriptive statistics were used to summarize the variables. The difficulty levels and floor and ceiling effects were determined for each item. Reliability was analyzed using internal consistency and inter-observer reliability. The validity analysis was performed considering face validity, content and construct validity (through exploratory factor analysis), and criterion validity. Internal reliability and inter-observer reliability were higher than 0.80. The construct validity analysis suggested a three-factor model accounting for 37.1% of the variance. These three factors were named 'Nursing process', 'Communication skills', and 'Safe practice'. A significant correlation was found between the scores obtained and the students' grades in general, as well as with the grades obtained in subjects with clinical content. The assessment tool has proven to be sufficiently reliable and valid for the assessment of the clinical competence of nursing students using standardized patients

  4. Standard guide for hot cell specialized support equipment and tools

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 Intent: 1.1.1 This guide presents practices and guidelines for the design and implementation of equipment and tools to assist assembly, disassembly, alignment, fastening, maintenance, or general handling of equipment in a hot cell. Operating in a remote hot cell environment significantly increases the difficulty and time required to perform a task compared to completing a similar task directly by hand. Successful specialized support equipment and tools minimize the required effort, reduce risks, and increase operating efficiencies. 1.2 Applicability: 1.2.1 This guide may apply to the design of specialized support equipment and tools anywhere it is remotely operated, maintained, and viewed through shielding windows or by other remote viewing systems. 1.2.2 Consideration should be given to the need for specialized support equipment and tools early in the design process. 1.2.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conv...

  5. Point-of-Care Diagnostic Device for Traumatic Pneumothorax: Low Sensitivity of the Unblinded PneumoScan™

    Directory of Open Access Journals (Sweden)

    M. Rehfeldt

    2018-01-01

    Full Text Available Background. Traumatic Pneumothorax (PTX is a potentially life-threatening injury. It requires a fast and accurate diagnosis and treatment, but diagnostic tools are limited. A new point-of-care device (PneumoScan based on micropower impulse radar (MIR promises to diagnose a PTX within seconds. In this study, we compare standard diagnostics with PneumoScan during shock-trauma-room management. Patients and Methods. Patients with blunt or penetrating chest trauma were consecutively included in the study. All patients were examined including clinical examination with auscultation (CE and supine chest radiography (CXR. In addition, PneumoScan-readings and thoracic ultrasound scan (US were performed. Computed tomography (CT served as gold standard. Results. CT scan revealed PTX in 11 patients. PneumoScan detected two PTX correctly but missed nine. 15 false-positive results were found by PneumoScan, leading to a sensitivity of 20% and specificity of 80%. Six PTX were detected through CE (sensitivity: 54,5%. CXR detected four (sensitivity: 27,3% and thoracic US two PTX correctly (sensitivity: 25%. Conclusion. The unblinded PneumoScan prototype did not confirm the promising results of previous studies. The examined standard diagnostics and thoracic US showed rather weak sensitivity as well. Until now, there is no appropriate point-of-care tool to rule out PTX.

  6. Using three-dimensional-computerized tomography as a diagnostic tool for temporo-mandibular joint ankylosis: a case report.

    Science.gov (United States)

    Kao, S Y; Chou, J; Lo, J; Yang, J; Chou, A P; Joe, C J; Chang, R C

    1999-04-01

    Roentgenographic examination has long been a useful diagnostic tool for temporo-mandibular joint (TMJ) disease. The methods include TMJ tomography, panoramic radiography and computerized tomography (CT) scan with or without injection of contrast media. Recently, three-dimensional CT (3D-CT), reconstructed from the two-dimensional image of a CT scan to simulate the soft tissue or bony structure of the real target, was proposed. In this report, a case of TMJ ankylosis due to traumatic injury is presented. 3D-CT was employed as one of the presurgical roentgenographic diagnostic tools. The conventional radiographic examination including panoramic radiography and tomography showed lesions in both sides of the mandible. CT scanning further suggested that the right-sided lesion was more severe than that on the left. With 3D-CT image reconstruction the size and extent of the lesions were clearly observable. The decision was made to proceed with an initial surgical approach on the right side. With condylectomy and condylar replacement using an autogenous costochondral graft on the right side, the range of mouth opening improved significantly. In this case report, 3D-CT demonstrates its advantages as a tool for the correct and precise diagnosis of TMJ ankylosis.

  7. Intercomparison of ionization chambers in standard X-ray beams, at radiotherapy, diagnostic radiology and radioprotection levels

    International Nuclear Information System (INIS)

    Bessa, Ana Carolina Moreira de

    2007-01-01

    Since the calibration of radiation measurement instruments and the knowledge of their major characteristics are very important subjects, several different types of ionization chambers were inter compared in terms of their calibration coefficients and their energy dependence, in radiotherapy, diagnostic radiology and radioprotection standard beams. An intercomparison of radionuclide calibrators for nuclear medicine was performed, using three radionuclides: 67 Ga, 201 Tl and 99m Tc; the results obtained were all within the requirements of the national standard CNEN-NE-3.05. In order to complete the range of radiation qualities of the Calibration Laboratory of IPEN, standard radiation beam qualities, radiation protection and low energy radiation therapy levels, were established, according international recommendations. Three methodologies for the calibration of unsealed ionization chambers in X-ray beams were studied and compared. A set of Victoreen ionization chambers, specially designed for use in laboratorial intercomparisons, was submitted to characterization tests. The performance of these Victoreen ionization chambers showed that they are suitable for use in radioprotection beams, because the results obtained agree with international recommendations. However, these Victoreen ionization chambers can be used in radiotherapy and diagnostic radiology beams only with some considerations, since their performance in these beams, especially in relation to the energy dependence and stabilization time tests, did not agree with the international recommendations for dosimeters used in radiotherapy and diagnostic radiology beams. This work presents data on the performance of several types of ionization chambers in different X-ray beams, that may be useful for choosing the appropriate instrument for measurements in ionizing radiation beams. (author)

  8. Intercomparison of ionization chambers in standard X-ray beams, at radiotherapy, diagnostic radiology and radioprotection levels

    International Nuclear Information System (INIS)

    Bessa, Ana Carolina Moreira de

    2006-01-01

    Since the calibration of radiation measurement instruments and the knowledge of their major characteristics are very important subjects, several different types of ionization chambers were intercompared in terms of their calibration coefficients and their energy dependence, in radiotherapy, diagnostic radiology and radioprotection standard beams. An intercomparison of radionuclide calibrators for nuclear medicine was performed, using three radionuclides: 67 Ga, 201 Tl and 99m Tc; the results obtained were all within the requirements of the national standard CNEN-NE-3.05. In order to complete the range of radiation qualities of the Calibration Laboratory of IPEN, standard radiation beam qualities, radiation protection and low energy radiation therapy levels, were established, according international recommendations. Three methodologies for the calibration of unsealed ionization chambers in X-ray beams were studied and compared. A set of Victoreen ionization chambers, specially designed for use in laboratorial intercomparisons, was submitted to characterization tests. The performance of these Victoreen ionization chambers showed that they are suitable for use in radioprotection beams, because the results obtained agree with international recommendations. However, these Victoreen ionization chambers can be used in radiotherapy and diagnostic radiology beams only with some considerations, since their performance in these beams, especially in relation to the energy dependence and stabilization time tests, did not agree with the international recommendations for dosimeters used in radiotherapy and diagnostic radiology beams. This work presents data on the performance of several types of ionization chambers in different X-ray beams, that may be useful for choosing the appropriate instrument for measurements in ionizing radiation beams. (author)

  9. 76 FR 28990 - Ultra High Throughput Sequencing for Clinical Diagnostic Applications-Approaches To Assess...

    Science.gov (United States)

    2011-05-19

    ... Web cast of the public meeting, you must register online at http://www.fda.gov/MedicalDevices/News... technologies are currently extensively used in research and are entering clinical diagnostic use; they are... technologies for clinical applications, appropriate evaluation tools (e.g., standards, well established...

  10. Diagnostics aid for mass spectrometer trouble-shooting

    International Nuclear Information System (INIS)

    Filby, E.E.; Rankin, R.A.; Webb, G.W.

    1987-01-01

    The ''MS Expert'' system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho Chemical Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills avilable on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system ''shell.'' The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to the rule base. The overall analysis provides the user with a set of possible solutions to the observed problems, graded as to their probabilities. Besides the trouble-shooting benefits expected from this system, it will also provide structures diagnostic training for lab personnel. In addition, development of the system knowledge base has already produced a better understanding of instrument behavior. Two key findings are that a good user interface is necessary for full acceptance of the tool, and a development system should include standard programming capabilities as well as the expert system shell. 22 refs., 5 figs

  11. Diagnostics aid for mass spectrometer trouble-shooting

    International Nuclear Information System (INIS)

    Filby, E.E.; Rankin, R.A.; Webb, G.W.

    1987-01-01

    The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to the rule base. The overall analysis provides the user with a set of possible solutions to the observed problems, graded as to their probabilities. Besides the trouble-shooting benefits expected from this system, it also provides structured diagnostic training for lab personnel. In addition, development of the system knowledge base has already produced a better understanding of instrument behavior. Two key findings are that a good user interface is necessary for full acceptance of the tool, and, a development system should include standard programming capabilities as well as the expert system shell

  12. Agreement and Diagnostic Performance of FITNESSGRAM®, International Obesity Task Force, and Hungarian National BMI Standards

    Science.gov (United States)

    Laurson, Kelly R.; Welk, Gregory J.; Marton, Orsolya; Kaj, Mónika; Csányi, Tamás

    2015-01-01

    Purpose: This study examined agreement between all 3 standards (as well as relative diagnostic associations with metabolic syndrome) using a representative sample of youth from the Hungarian National Youth Fitness Study. Method: Body mass index (BMI) was assessed in a field sample of 2,352 adolescents (ages 10-18.5 years) and metabolic syndrome…

  13. Diagnostic nerve ultrasonography; Diagnostische Nervensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, T. [Universitaet zu Luebeck CBBM, Haus 66, Institut fuer Neurogenetik, Luebeck (Germany); Grimm, A. [Universitaetsklinikum Tuebingen, Klinik und Poliklinik fuer Neurologie, Tuebingen (Germany); Schelle, T. [Staedtisches Klinikum Dessau, Neurologische Klinik, Dessau (Germany)

    2017-03-15

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [German] Fuer die Diagnostik von Nervenlaesionen ist ein bildgebendes Verfahren zur Darstellung des peripheren Nervs und seiner ihn umgebenden Strukturen fuer eine aetiologische Einordnung erforderlich. Mit der klinisch-neurologischen Untersuchung und Elektrophysiologie ist eine funktionelle Aussage ueber die Nervenlaesion moeglich. In der Standard-MRT-Untersuchung wird der periphere Nerv nur unzureichend gut dargestellt. Die MRT-Neurographie ist ein sehr gutes, aber auch zeit- und ressourcenintensives Verfahren. Nutzung des Ultraschalls fuer die

  14. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    Science.gov (United States)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  15. Comparison of different stains in imprint cytology with the conventional diagnostic tools in detection of Helicobacter pylori infection

    Directory of Open Access Journals (Sweden)

    Shashikant Adlekha

    2015-01-01

    Full Text Available Background: Helicobacter pylori (H. pylori infection is one of the most common causes of gastrointestinal morbidity and mortality worldwide. Early diagnosis of infection is imperative for the cure of distressing symptoms and prevention of complications. Objective: The objective of the study is to evaluate imprint cytology of gastric biopsy specimens as a rapid and cost-effective diagnostic tool and its comparison with conventional diagnostic tests. Materials and Methods: Antral biopsies were collected from 130 patients and evaluated for H. pylori infection by imprint cytology and histopathological examination by different stains and rapid urease test (RUT. Histopathological features of gastric biopsy specimens were also assessed. Results: A total of 118 patients showed H. pylori infection by two or more methods. Giemsa histology showed highest sensitivity, specificity, positive predictive value, negative predictive value and Youden′s Index (YI. Among imprint cytology stain methods, toluidine blue showed highest sensitivity and highest YI was obtained for PAP stain. Conclusion: Helicobacter pylori infection is associated with gastric mucosa changes like chronic active gastritis, atrophy, intestinal metaplasia, ulceration and carcinoma. Imprint cytology has high sensitivity and comparable predictive values to conventional diagnostic tools-histopathological examination and RUT in the detection of H. pylori infection.

  16. Plasma diagnostic tools for optimizing negative hydrogen ion sources

    International Nuclear Information System (INIS)

    Fantz, U.; Falter, H.D.; Franzen, P.; Speth, E.; Hemsworth, R.; Boilson, D.; Krylov, A.

    2006-01-01

    The powerful diagnostic tool of optical emission spectroscopy is used to measure the plasma parameters in negative hydrogen ion sources based on the surface mechanism. Results for electron temperature, electron density, atomic-to-molecular hydrogen density ratio, and gas temperature are presented for two types of sources, a rf source and an arc source, which are currently under development for a neutral beam heating system of ITER. The amount of cesium in the plasma volume is obtained from cesium radiation: the Cs neutral density is five to ten orders of magnitude lower than the hydrogen density and the Cs ion density is two to three orders of magnitude lower than the electron density in front of the grid. It is shown that monitoring of cesium lines is very useful for monitoring the cesium balance in the source. From a line-ratio method negative ion densities are determined. In a well-conditioned source the negative ion density is of the same order of magnitude as the electron density and correlates with extracted current densities

  17. Blood culture-negative endocarditis: Improving the diagnostic yield using new diagnostic tools.

    Science.gov (United States)

    Fournier, Pierre-Edouard; Gouriet, Frédérique; Casalta, Jean-Paul; Lepidi, Hubert; Chaudet, Hervé; Thuny, Franck; Collart, Frédéric; Habib, Gilbert; Raoult, Didier

    2017-11-01

    Blood culture-negative endocarditis (BCNE) may represent up to 70% of all endocarditis cases, depending on series. From 2001 to 2009, we implemented in our laboratory a multimodal diagnostic strategy for BCNE that included systematized testing of blood, and when available, valvular biopsy specimens using serological, broad range molecular, and histopathological assays. A causative microorganism was identified in 62.7% of patients.In this study from January 2010 to December 2015, in an effort to increase the number of identified causative microorganisms, we prospectively added to our diagnostic protocol specific real-time (RT) polymerase chain reaction (PCR) assays targeting various endocarditis agents, and applied them to all patients with BCNE admitted to the 4 public hospitals in Marseille, France.A total of 283 patients with BCNE were included in the study. Of these, 177 were classified as having definite endocarditis. Using our new multimodal diagnostic strategy, we identified an etiology in 138 patients (78.0% of cases). Of these, 3 were not infective (2.2%) and 1 was diagnosed as having Mycobacterium bovis BCG endocarditis. By adding specific PCR assays from blood and valvular biopsies, which exhibited a significantly greater sensitivity (P < 10) than other methods, causative agents, mostly enterococci, streptococci, and zoonotic microorganisms, were identified in an additional 27 patients (14 from valves only, 11 from blood only, and 2 from both). Finally, in another 107 patients, a pathogen was detected using serology in 37, valve culture in 8, broad spectrum PCR from valvular biopsies and blood in 19 and 2, respectively, immunohistochemistry from valves in 3, and a combination of several assays in 38.By adding specific RT-PCR assays to our systematic PCR testing of patients with BCNE, we increased the diagnostic efficiency by 24.3%, mostly by detecting enterococci and streptococci that had not been detected by other diagnostic methods, but also agents

  18. Software Tools to Support the Assessment of System Health

    Science.gov (United States)

    Melcher, Kevin J.

    2013-01-01

    This presentation provides an overview of three software tools that were developed by the NASA Glenn Research Center to support the assessment of system health: the Propulsion Diagnostic Method Evaluation Strategy (ProDIMES), the Systematic Sensor Selection Strategy (S4), and the Extended Testability Analysis (ETA) tool. Originally developed to support specific NASA projects in aeronautics and space, these software tools are currently available to U.S. citizens through the NASA Glenn Software Catalog. The ProDiMES software tool was developed to support a uniform comparison of propulsion gas path diagnostic methods. Methods published in the open literature are typically applied to dissimilar platforms with different levels of complexity. They often address different diagnostic problems and use inconsistent metrics for evaluating performance. As a result, it is difficult to perform a one ]to ]one comparison of the various diagnostic methods. ProDIMES solves this problem by serving as a theme problem to aid in propulsion gas path diagnostic technology development and evaluation. The overall goal is to provide a tool that will serve as an industry standard, and will truly facilitate the development and evaluation of significant Engine Health Management (EHM) capabilities. ProDiMES has been developed under a collaborative project of The Technical Cooperation Program (TTCP) based on feedback provided by individuals within the aircraft engine health management community. The S4 software tool provides a framework that supports the optimal selection of sensors for health management assessments. S4 is structured to accommodate user ]defined applications, diagnostic systems, search techniques, and system requirements/constraints. One or more sensor suites that maximize this performance while meeting other user ]defined system requirements that are presumed to exist. S4 provides a systematic approach for evaluating combinations of sensors to determine the set or sets of

  19. Monte Carlo tools for Beyond the Standard Model Physics , April 14-16

    DEFF Research Database (Denmark)

    Badger...[], Simon; Christensen, Christian Holm; Dalsgaard, Hans Hjersing

    2011-01-01

    This workshop aims to gather together theorists and experimentalists interested in developing and using Monte Carlo tools for Beyond the Standard Model Physics in an attempt to be prepared for the analysis of data focusing on the Large Hadron Collider. Since a large number of excellent tools....... To identify promising models (or processes) for which the tools have not yet been constructed and start filling up these gaps. To propose ways to streamline the process of going from models to events, i.e. to make the process more user-friendly so that more people can get involved and perform serious collider...

  20. Quantifying traces of tool use: a novel morphometric analysis of damage patterns on percussive tools.

    Directory of Open Access Journals (Sweden)

    Matthew V Caruana

    Full Text Available Percussive technology continues to play an increasingly important role in understanding the evolution of tool use. Comparing the archaeological record with extractive foraging behaviors in nonhuman primates has focused on percussive implements as a key to investigating the origins of lithic technology. Despite this, archaeological approaches towards percussive tools have been obscured by a lack of standardized methodologies. Central to this issue have been the use of qualitative, non-diagnostic techniques to identify percussive tools from archaeological contexts. Here we describe a new morphometric method for distinguishing anthropogenically-generated damage patterns on percussive tools from naturally damaged river cobbles. We employ a geomatic approach through the use of three-dimensional scanning and geographical information systems software to statistically quantify the identification process in percussive technology research. This will strengthen current technological analyses of percussive tools in archaeological frameworks and open new avenues for translating behavioral inferences of early hominins from percussive damage patterns.

  1. Quantifying Traces of Tool Use: A Novel Morphometric Analysis of Damage Patterns on Percussive Tools

    Science.gov (United States)

    Caruana, Matthew V.; Carvalho, Susana; Braun, David R.; Presnyakova, Darya; Haslam, Michael; Archer, Will; Bobe, Rene; Harris, John W. K.

    2014-01-01

    Percussive technology continues to play an increasingly important role in understanding the evolution of tool use. Comparing the archaeological record with extractive foraging behaviors in nonhuman primates has focused on percussive implements as a key to investigating the origins of lithic technology. Despite this, archaeological approaches towards percussive tools have been obscured by a lack of standardized methodologies. Central to this issue have been the use of qualitative, non-diagnostic techniques to identify percussive tools from archaeological contexts. Here we describe a new morphometric method for distinguishing anthropogenically-generated damage patterns on percussive tools from naturally damaged river cobbles. We employ a geomatic approach through the use of three-dimensional scanning and geographical information systems software to statistically quantify the identification process in percussive technology research. This will strengthen current technological analyses of percussive tools in archaeological frameworks and open new avenues for translating behavioral inferences of early hominins from percussive damage patterns. PMID:25415303

  2. MET Standards for Electro-Technical Officers

    Directory of Open Access Journals (Sweden)

    Janusz Mindykowski

    2014-12-01

    Full Text Available The paper deals with one of the most important changes in the STCW 1978 as amended in 2010 Convention, from the point of view of the watchkeeping officers responsible for control, maintenance, diagnostic and repair of electrical and electronic installations on board of ships. Some reasons, why the MET Standards for Electro-Technical had to be developed and implemented are shortly analyzed and described. A legislative way towards and a short description of the minimum standards competence for ETO are presented. Next, new tools supporting ETO’s standards implementation are appointed. Finally, the future works as well as the concluding remarks concerning discussed issue are formulated and commented on.

  3. Improvements in diagnostic tools for early detection of psoriatic arthritis.

    Science.gov (United States)

    D'Angelo, Salvatore; Palazzi, Carlo; Gilio, Michele; Leccese, Pietro; Padula, Angela; Olivieri, Ignazio

    2016-11-01

    Psoriatic arthritis (PsA) is a heterogeneous chronic inflammatory disease characterized by a wide clinical spectrum. The early diagnosis of PsA is currently a challenging topic. Areas covered: The literature was extensively reviewed for studies addressing the topic area "diagnosis of psoriatic arthritis". This review will summarize improvements in diagnostic tools, especially referral to the rheumatologist, the role of patient history and clinical examination, laboratory tests, and imaging techniques in getting an early and correct diagnosis of PsA. Expert commentary: Due to the heterogeneity of its expression, PsA may be easily either overdiagnosed or underdiagnosed. A diagnosis of PsA should be taken into account every time a patient with psoriasis or a family history of psoriasis shows peripheral arthritis, especially if oligoarticular or involving the distal interphalangeal joints, enthesitis or dactylitis. Magnetic resonance imaging and ultrasonography are useful for diagnosing PsA early, particularly when isolated enthesitis or inflammatory spinal pain occur.

  4. An update on the use of cerebrospinal fluid analysis as a diagnostic tool in multiple sclerosis.

    Science.gov (United States)

    Gastaldi, Matteo; Zardini, Elisabetta; Franciotta, Diego

    2017-01-01

    Intrathecal B-lymphocyte activation is a hallmark of multiple sclerosis (MS), a multi-factorial inflammatory-demyelinating disease of the central nervous system. Such activation has a counterpart in the cerebrospinal fluid (CSF) oligoclonal IgG bands (OCB), whose diagnostic role in MS has been downgraded within the current McDonald's criteria. With a theoretico-practical approach, the authors review the physiopathological basis of the CSF dynamics, and the state-of-the-art of routine CSF analysis and CSF biomarkers in MS. Areas covered: The authors discuss pros and cons of CSF analysis, including critical evaluations of both well-established, and promising diagnostic and prognostic laboratory tools. New acquisitions on the CSF and cerebral interstitial fluid dynamics are also presented. The authors searched the PubMed database for English-language articles reported between January 2010 and June 2016, using the key words 'multiple sclerosis', 'cerebrospinal fluid', 'oligoclonal bands'. Reference lists of relevant articles were scanned for additional studies. Expert commentary: The availability of performing high-quality, routine CSF tests in specialized laboratories, the emerging potential of novel CSF biomarkers, and the trend for early treatments should induce a reappraisal of CSF analysis for diagnostic and prognostic purposes in MS. Further procedural and methodological improvements seem to be necessary in both research and translational diagnostic CSF settings.

  5. Conventional and molecular diagnostic strategies for prosthetic joint infections.

    Science.gov (United States)

    Esteban, Jaime; Sorlí, Luisa; Alentorn-Geli, Eduard; Puig, Lluís; Horcajada, Juan P

    2014-01-01

    An accurate diagnosis of prosthetic joint infection (PJI) is the mainstay for an optimized clinical management. This review analyzes different diagnostic strategies of PJI, with special emphasis on molecular diagnostic tools and their current and future applications. Until now, the culture of periprosthetic tissues has been considered the gold standard for the diagnosis of PJI. However, sonication of the implant increases the sensitivity of those cultures and is being increasingly adopted by many centers. Molecular diagnostic methods compared with intraoperative tissue culture, especially if combined with sonication, have a higher sensitivity, a faster turnaround time and are not influenced by previous antimicrobial therapy. However, they still lack a system for detection of antimicrobial susceptibility, which is crucial for an optimized and less toxic therapy of PJI. More studies are needed to assess the clinical value of these methods and their cost-effectiveness.

  6. A randomised controlled study of standard versus accelerated deflation of the Terumo radial band haemostasis device after transradial diagnostic cardiac catheterisation.

    Science.gov (United States)

    Deuling, J Han; Vermeulen, Robert P; van den Heuvel, Ad Fm; Schurer, Remco Aj; van der Harst, Pim

    2017-04-01

    Radial access is the preferential access route in patients undergoing diagnostic coronary angiography. We hypothesised that we could reduce hospital stay and improve patient comfort by accelerated deflation of the radial compression device (Terumo radial band). The aim of this study was to compare accelerated pressure reduction with a standard Terumo radial band protocol with regard to local bleeding complications and reported pain scores after cardiac catheterisation. We performed a single centre prospective randomised trial to compare accelerated care to standard care for patients undergoing diagnostic catheterisation through radial access. Patients in the accelerated care group started deflation after 1 hour, with a 2 ml/10-minute interval. Patients in the standard care group started after 2 hours with additional steps of deflation at 3 and 4 hours. Of the 173 analysed patients 86 received accelerated care and 87 patients standard care. A total of 19 patients had pulsatile bleeding, which occurred similarly in the two groups (standard care 11 vs. accelerated care 8, P=0.47). The time to Terumo radial band removal was on average 129 minutes shorter for accelerated care patients compared to standard care ( P<0.01). At 1 hour after Terumo radial band placement, accelerated care patients more often reported pain scores of 0 than standard care patients (89% vs. 74%, P=0.02). There was no increase in local bleedings in the accelerated pressure reduction of the Terumo radial band after diagnostic cardiac catheterisation, increasing patient comfort and reducing hospital stay. These findings will further facilitate the widespread implementation of radial access.

  7. The premature ejaculation diagnostic tool (PEDT): linguistic validity of the Chinese version.

    Science.gov (United States)

    Huang, Yan-Ping; Chen, Bin; Ping, Ping; Wang, Hong-Xiang; Hu, Kai; Zhang, Tao; Yang, Hao; Jin, Yan; Yang, Qi; Huang, Yi-Ran

    2014-09-01

    The premature ejaculation diagnostic tool (PEDT) was developed to standardize the diagnosis of PE and has been applied in many countries. However, a linguistic validation of the Chinese version of PEDT does not exist. This study aims to undertake the Chinese validation of the PEDT and to evaluate its association with self-estimated intravaginal ejaculatory latency time (IELT) and clinical expert diagnosis of PE. A Chinese version of PEDT was confirmed by andrologist and bilingual linguist. Participants were recruited among seven different communities of Shanghai from 2011 to 2012, and their information regarding self-reported PE, self-estimated IELT, expert diagnosis of PE, and PEDT scores were collected. Validity of the PEDT and its association with clinical expert diagnosis of PE and self-estimated IELT were analyzed. A total of 143 patients without PE (mean age 55.11 ± 7.65 years) and 100 men with PE (mean age 53.07 ± 8.08 years) were enrolled for validation. Of the patients in PE group, the number of men reporting self-estimated IELTs of ≤1, 1-2, and >2 minutes were 34 (34.0%), 22 (22.0%), and 44 (44.0%), respectively. The Cronbach's alpha score (α = 0.77) showed adequate internal consistency, and the test-retest correlation coefficients of each item (r ≥ 0.70, P IELT (ρ = -0.396, P IELT ≤1 minute). The Chinese version of PEDT is valid in screening the presence of PE among Chinese men. The PEDT showed an adequate negative correlation with self-estimated IELT and an excellent concordance with clinician diagnosis of PE. © 2014 International Society for Sexual Medicine.

  8. Lithium Battery Transient Response as a Diagnostic Tool

    Science.gov (United States)

    Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.

    2018-05-01

    Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.

  9. Reducing bending stress in external spur gears by redesign of the standard cutting tool

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2009-01-01

    For the design of gears the stress due to bending plays a significant role. The stress from bending is largest in the root of the gear teeth, and the magnitude of the maximum stress is controlled by the nominal bending stress and stress concentration due to the geometric shape of the tooth....... In this work the bending stress of involute teeth is minimized by shape optimizing the tip of the standard cutting tool. By redesign of the tip of the standard cutting tool we achieve that the functional part of the teeth stays the same while at the same time the root shape is changed so that a reduction...... of the stresses results. The tool tip shape is described by different parameterizations that use the super ellipse as the central shape. For shape optimization it is important that the shape is given analytically. The shape of the cut tooth that is the envelope of the cutting tool is found analytically...

  10. Vibration Diagnostics as an effective Tool for Testing Engines of Internal Combustion

    Directory of Open Access Journals (Sweden)

    Ferenc Dömötör

    2017-10-01

    Full Text Available There are several methods of automotive diagnostics used in services to detect a large variety of faults and damages of various parts of engines of internal combustion. Undoubtedly, they are effective, but they are simply unable to find all types of mechanical faults occurring during the operation. This is the reason why authors of this paper tried to use a special tool, which has been proven for years for detecting faults of rolling element bearing in rotating machinery. During their research, the authors tried to find valuable results by measuring vibration of various parts of engines. Three items were tested, a Diesel engine and two Otto motors. A large number of measurements have been taken at various speed, at different points, in different directions, with different parameter setup, etc. However, there was one setup which has been applied to all three engines. It is the measurement setup of vibration velocity, in the frequency range of 2 Hz-300 Hz. Valuable consequences have been found regarding the clogging of the air filters and the exhaust systems. As a conclusion the authors expressed their opinion, that, apart from the traditional diagnostic methods used in services, vibration measurements can also be useful, especially for detecting faults of rolling element bearings.

  11. Diagnostic X-Ray dosimeters using standard Float Zone (FZ) and XRA-50 commercial diodes

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, Josemary A.C.; Bueno, Carmen C., E-mail: josemary@ipen.br, E-mail: ccbueno@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), São Paulo, SP (Brazil); Barros, Vinicius S.M.; Asfora, Viviane K.; Khoury, Helen J., E-mail: vsmdbarros@gmail.com, E-mail: vikhoury@gmail.com, E-mail: hjkhoury@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Física

    2017-07-01

    The results obtained with a standard float zone (FZ) silicon diode, processed at the Helsinki Institute of Physics, used as on-line diagnostic X-ray dosimeter are described in this work. The device was connected in the short circuit current mode to the input of an integrating electrometer. The response repeatability and the current sensitivity coefficient of the diode were measured with diagnostic X-ray beams in the range of 40-80 kV. The dose-response of the device, evaluated from 10 mGy up to 500 mGy, was linear with high charge sensitivity. Nevertheless, significant energy dependence was observed in the charge sensitivity of FZ device for energies below 70 kV. The dosimetric characteristics of this FZ diode were compared to those of an XRA-50 commercial Si diode, specially designed to X-ray dosimetry. The results obtained with the FZ diode evidenced that it can be an alternative choice for diagnostic X-ray dosimetry, although it needs to be calibrated for individual X-ray beam energies. The studies of long-term stability and the radiation hardness of these diodes are under way. (author)

  12. Novel molecular diagnostic tools for malaria elimination: a review of options from the point of view of high-throughput and applicability in resource limited settings.

    Science.gov (United States)

    Britton, Sumudu; Cheng, Qin; McCarthy, James S

    2016-02-16

    As malaria transmission continues to decrease, an increasing number of countries will enter pre-elimination and elimination. To interrupt transmission, changes in control strategies are likely to require more accurate identification of all carriers of Plasmodium parasites, both symptomatic and asymptomatic, using diagnostic tools that are highly sensitive, high throughput and with fast turnaround times preferably performed in local health service settings. Currently available immunochromatographic lateral flow rapid diagnostic tests and field microscopy are unlikely to consistently detect infections at parasite densities less than 100 parasites/µL making them insufficiently sensitive for detecting all carriers. Molecular diagnostic platforms, such as PCR and LAMP, are currently available in reference laboratories, but at a cost both financially and in turnaround time. This review describes the recent progress in developing molecular diagnostic tools in terms of their capacity for high throughput and potential for performance in non-reference laboratories for malaria elimination.

  13. Multimodal nonlinear microscopy: A powerful label-free method for supporting standard diagnostics on biological tissues

    Directory of Open Access Journals (Sweden)

    Riccardo Cicchi

    2014-09-01

    Full Text Available The large use of nonlinear laser scanning microscopy in the past decade paved the way for potential clinical application of this imaging technique. Modern nonlinear microscopy techniques offer promising label-free solutions to improve diagnostic performances on tissues. In particular, the combination of multiple nonlinear imaging techniques in the same microscope allows integrating morphological with functional information in a morpho-functional scheme. Such approach provides a high-resolution label-free alternative to both histological and immunohistochemical examination of tissues and is becoming increasingly popular among the clinical community. Nevertheless, several technical improvements, including automatic scanning and image analysis, are required before the technique represents a standard diagnostic method. In this review paper, we highlight the capabilities of multimodal nonlinear microscopy for tissue imaging, by providing various examples on colon, arterial and skin tissues. The comparison between images acquired using multimodal nonlinear microscopy and histology shows a good agreement between the two methods. The results demonstrate that multimodal nonlinear microscopy is a powerful label-free alternative to standard histopathological methods and has the potential to find a stable place in the clinical setting in the near future.

  14. Development and Assessment of a Diagnostic Tool to Identify Organic Chemistry Students' Alternative Conceptions Related to Acid Strength

    Science.gov (United States)

    McClary, LaKeisha M.; Bretz, Stacey Lowery

    2012-01-01

    The central goal of this study was to create a new diagnostic tool to identify organic chemistry students' alternative conceptions related to acid strength. Twenty years of research on secondary and college students' conceptions about acids and bases has shown that these important concepts are difficult for students to apply to qualitative problem…

  15. A Quasi-Universal Nonword Repetition Task as a Diagnostic Tool for Bilingual Children Learning Dutch as a Second Language.

    Science.gov (United States)

    Boerma, Tessel; Chiat, Shula; Leseman, Paul; Timmermeister, Mona; Wijnen, Frank; Blom, Elma

    2015-12-01

    This study evaluated a newly developed quasi-universal nonword repetition task (Q-U NWRT) as a diagnostic tool for bilingual children with language impairment (LI) who have Dutch as a 2nd language. The Q-U NWRT was designed to be minimally influenced by knowledge of 1 specific language in contrast to a language-specific NWRT with which it was compared. One hundred twenty monolingual and bilingual children with and without LI participated (30 per group). A mixed-design analysis of variance was used to investigate the effects of LI and bilingualism on the NWRTs. Receiver operating characteristic analyses were conducted to evaluate the instruments' diagnostic value. Large negative effects of LI were found on both NWRTs, whereas negative effects of bilingualism only occurred on the language-specific NWRT. Both instruments had high clinical accuracy in the monolingual group, but only the Q-U NWRT had high clinical accuracy in the bilingual group. This study indicates that the Q-U NWRT is a promising diagnostic tool to help identify LI in bilingual children learning Dutch as a 2nd language. The instrument was clinically accurate in both a monolingual and bilingual group of children and seems better able to disentangle LI from language disadvantage than more language-specific measures.

  16. A simple web-based tool to compare freshwater fish data collected using AFS standard methods

    Science.gov (United States)

    Bonar, Scott A.; Mercado-Silva, Norman; Rahr, Matt; Torrey, Yuta T.; Cate, Averill

    2016-01-01

    The American Fisheries Society (AFS) recently published Standard Methods for Sampling North American Freshwater Fishes. Enlisting the expertise of 284 scientists from 107 organizations throughout Canada, Mexico, and the United States, this text was developed to facilitate comparisons of fish data across regions or time. Here we describe a user-friendly web tool that automates among-sample comparisons in individual fish condition, population length-frequency distributions, and catch per unit effort (CPUE) data collected using AFS standard methods. Currently, the web tool (1) provides instantaneous summaries of almost 4,000 data sets of condition, length frequency, and CPUE of common freshwater fishes collected using standard gears in 43 states and provinces; (2) is easily appended with new standardized field data to update subsequent queries and summaries; (3) compares fish data from a particular water body with continent, ecoregion, and state data summaries; and (4) provides additional information about AFS standard fish sampling including benefits, ongoing validation studies, and opportunities to comment on specific methods. The web tool—programmed in a PHP-based Drupal framework—was supported by several AFS Sections, agencies, and universities and is freely available from the AFS website and fisheriesstandardsampling.org. With widespread use, the online tool could become an important resource for fisheries biologists.

  17. Monitoring of lobectomy in cystic fibrosis with electrical impedance tomography - a new diagnostic tool.

    Science.gov (United States)

    Lehmann, Sylvia; Tenbrock, Klaus; Schrading, Simone; Pikkemaat, Robert; Antink, Christoph Hoog; Santos, Susana; Spillner, Jan Wilhelm; Wagner, Norbert; Leonhardt, Steffen

    2014-12-01

    Electrical impedance tomography (EIT) is a radiation-free technique generating cross-sectional images of the lung. EIT visualizes global and regional ventilation by illustrating the distribution of electrical bioimpedance. With an electrode belt around the patient's thorax, rotating injection-couples of a harmless alternating current allow voltage measurement of the remaining electrodes. This enables the reconstruction of a tomogram with highly dynamic changes within ventilation. We report on a female six-year-old patient with cystic fibrosis and complete destruction of the upper and middle lobe of the right lung. Lobectomy, a rare therapeutic option in patients with cystic fibrosis that needs to be considered in cases of severe localized destruction, was performed. We show a pre- and postoperative documentation of static (radiology) and dynamic investigation tools (spirometry) in correlation with EIT as a new non-invasive and radiation-free diagnostic tool for this patient group.

  18. Mobile Phones Democratize and Cultivate Next-Generation Imaging, Diagnostics and Measurement Tools

    Science.gov (United States)

    Ozcan, Aydogan

    2014-01-01

    In this article, I discuss some of the emerging applications and the future opportunities and challenges created by the use of mobile phones and their embedded components for the development of next-generation imaging, sensing, diagnostics and measurement tools. The massive volume of mobile phone users, which has now reached ~7 billion, drives the rapid improvements of the hardware, software and high-end imaging and sensing technologies embedded in our phones, transforming the mobile phone into a cost-effective and yet extremely powerful platform to run e.g., biomedical tests and perform scientific measurements that would normally require advanced laboratory instruments. This rapidly evolving and continuing trend will help us transform how medicine, engineering and sciences are practiced and taught globally. PMID:24647550

  19. Methods Developed by the Tools for Engine Diagnostics Task to Monitor and Predict Rotor Damage in Real Time

    Science.gov (United States)

    Baaklini, George Y.; Smith, Kevin; Raulerson, David; Gyekenyesi, Andrew L.; Sawicki, Jerzy T.; Brasche, Lisa

    2003-01-01

    Tools for Engine Diagnostics is a major task in the Propulsion System Health Management area of the Single Aircraft Accident Prevention project under NASA s Aviation Safety Program. The major goal of the Aviation Safety Program is to reduce fatal aircraft accidents by 80 percent within 10 years and by 90 percent within 25 years. The goal of the Propulsion System Health Management area is to eliminate propulsion system malfunctions as a primary or contributing factor to the cause of aircraft accidents. The purpose of Tools for Engine Diagnostics, a 2-yr-old task, is to establish and improve tools for engine diagnostics and prognostics that measure the deformation and damage of rotating engine components at the ground level and that perform intermittent or continuous monitoring on the engine wing. In this work, nondestructive-evaluation- (NDE-) based technology is combined with model-dependent disk spin experimental simulation systems, like finite element modeling (FEM) and modal norms, to monitor and predict rotor damage in real time. Fracture mechanics time-dependent fatigue crack growth and damage-mechanics-based life estimation are being developed, and their potential use investigated. In addition, wireless eddy current and advanced acoustics are being developed for on-wing and just-in-time NDE engine inspection to provide deeper access and higher sensitivity to extend on-wing capabilities and improve inspection readiness. In the long run, these methods could establish a base for prognostic sensing while an engine is running, without any overt actions, like inspections. This damage-detection strategy includes experimentally acquired vibration-, eddy-current- and capacitance-based displacement measurements and analytically computed FEM-, modal norms-, and conventional rotordynamics-based models of well-defined damages and critical mass imbalances in rotating disks and rotors.

  20. Hybrid tooling technologies and standardization for the manufacturing of inserts for micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Fillon, Bertrand; Azcarate, Sabino

    2007-01-01

    This paper is based on the European Platform’s activities within the 4M Network of Excellence “Multi-Material Micro Manufacturing”. To overpass limitations of the current existing micro tooling capabilities, a new generation of micro hybrid tooling technologies for micro replication was developed....... A metrological approach was applied to standardize the employed tooling processes (micro milling, µEDM, laser micromachining, electrochemical µ-milling). The micro tools were then tested with different polymers (PP, PP + nano fillers, PC, COC). The paper provides a comparison of these technologies concerning...

  1. The two most popular malnutrition screening tools in the light of the new ESPEN consensus definition of the diagnostic criteria for malnutrition.

    Science.gov (United States)

    Poulia, Kalliopi-Anna; Klek, Stanislaw; Doundoulakis, Ioannis; Bouras, Emmanouil; Karayiannis, Dimitrios; Baschali, Aristea; Passakiotou, Marili; Chourdakis, Michael

    2017-08-01

    The new definition of malnutrition in adults proposed recently by The European Society for Clinical Nutrition and Metabolism (ESPEN) changed the view on the issue and raised the question of the reliability of available diagnostic tools. Therefore, the aim of this study was to verify the accuracy of the two most commonly used screening tools by comparing their findings with the new ESPEN criteria. Nutritional screening was performed in 1146 (median age 60 years, interquartile range: 44-73 years, 617 males, 529 females) patients on admission to hospitals with two nutritional screening tools: Nutritional Risk Screening 2002 (NRS2002) and Malnutrition Universal Screening Tool (MUST). The screening results were then compared to the ESPEN new diagnostic criteria for malnutrition. According to the NRS2002 13.5% and 27.9% of the outpatients and hospitalized patients respectively were found to be at moderate/high risk of malnutrition. With the use of MUST 9.1% and 14.9% of the outpatients and hospitalized patients respectively were found to be at moderate/high risk of malnutrition. According to the ESPEN diagnostic criteria 6.4% and 11.3% of outpatients and hospitalized patients respectively were classified as malnourished. MUST was found to be better correlated to the latter for both outpatients (K = 0.777, p malnutrition screening tool in the light of the new ESPEN definition for malnutrition. According to our results, MUST was better correlated with ESPEN criteria for the definition of malnutrition, leading us to the conclusion that it can more efficiently identify the malnourished patients, during the screening process. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  2. Companion diagnostics and molecular imaging-enhanced approaches for oncology clinical trials.

    Science.gov (United States)

    Van Heertum, Ronald L; Scarimbolo, Robert; Ford, Robert; Berdougo, Eli; O'Neal, Michael

    2015-01-01

    In the era of personalized medicine, diagnostic approaches are helping pharmaceutical and biotechnology sponsors streamline the clinical trial process. Molecular assays and diagnostic imaging are routinely being used to stratify patients for treatment, monitor disease, and provide reliable early clinical phase assessments. The importance of diagnostic approaches in drug development is highlighted by the rapidly expanding global cancer diagnostics market and the emergent attention of regulatory agencies worldwide, who are beginning to offer more structured platforms and guidance for this area. In this paper, we highlight the key benefits of using companion diagnostics and diagnostic imaging with a focus on oncology clinical trials. Nuclear imaging using widely available radiopharmaceuticals in conjunction with molecular imaging of oncology targets has opened the door to more accurate disease assessment and the modernization of standard criteria for the evaluation, staging, and treatment responses of cancer patients. Furthermore, the introduction and validation of quantitative molecular imaging continues to drive and optimize the field of oncology diagnostics. Given their pivotal role in disease assessment and treatment, the validation and commercialization of diagnostic tools will continue to advance oncology clinical trials, support new oncology drugs, and promote better patient outcomes.

  3. Ares I-X Ground Diagnostic Prototype

    Science.gov (United States)

    Schwabacher, Mark A.; Martin, Rodney Alexander; Waterman, Robert D.; Oostdyk, Rebecca Lynn; Ossenfort, John P.; Matthews, Bryan

    2010-01-01

    The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.

  4. Creation of complexity assessment tool for patients receiving home care

    Directory of Open Access Journals (Sweden)

    Maria Leopoldina de Castro Villas Bôas

    2016-06-01

    Full Text Available Abstract OBJECTIVE To create and validate a complexity assessment tool for patients receiving home care from a public health service. METHOD A diagnostic accuracy study, with estimates for the tool's validity and reliability. Measurements of sensitivity and specificity were considered when producing validity estimates. The resulting tool was used for testing. Assessment by a specialized team of home care professionals was used as the gold standard. In the tool's reliability study, the authors used the Kappa statistic. The tool's sensitivity and specificity were analyzed using various cut-off points. RESULTS On the best cut-off point-21-with the gold standard, a sensitivity of 75.5% was obtained, with the limits of confidence interval (95% at 68.3% and 82.8% and specificity of 53.2%, with the limits of confidence interval (95% at 43.8% and 62.7%. CONCLUSION The tool presented evidence of validity and reliability, possibly helping in service organization at patient admission, care type change, or support during the creation of care plans.

  5. ULTRASONOGRAPHY, AN EFFECTIVE TOOL IN DIAGNOSING PLANTAR FASCIITIS: A SYSTEMATIC REVIEW OF DIAGNOSTIC TRIALS

    Science.gov (United States)

    Wyland, Matthew; Applequist, Lee; Bolowsky, Erin; Klingensmith, Heather; Virag, Isaac

    2016-01-01

    Background Plantar fasciitis (PF) is the most common cause of heel pain that affects 10% of the general population, whether living an athletic or sedentary lifestyle. The most frequent mechanism of injury is an inflammatory response that is caused by repetitive micro trauma. Many techniques are available to diagnose PF, including the use of ultrasonography (US). Purpose The purpose of this study is to systematically review and appraise previously published articles published between the years 2000 and 2015 that evaluated the effectiveness of using US in the process of diagnosing PF, as compared to alternative diagnostic methods. Methods A total of eight databases were searched to systematically review scholarly (peer reviewed) diagnostic and intervention articles pertaining to the ability of US to diagnose PF. Results Using specific key words the preliminary search yielded 264 articles, 10 of which were deemed relevant for inclusion in the study. Two raters independently scored each article using the 15 point modified QUADAS scale. Discussion Six studies compared the diagnostic efficacy of US to another diagnostic technique to diagnose PF, and four studies focused on comparing baseline assessment of plantar fascia before subsequent intervention. The most notable US outcomes measured were plantar fascia thickness, enthesopathy, and hypoechogenicity. Conclusion US was found to be accurate and reliable compared to alternative reference standards like MRI in the diagnosis of PF. The general advantages of US (e.g. cost efficient, ease of administration, non-invasive, limited contraindications) make it a superior diagnostic modality in the diagnosis of PF. US should be considered in rehabilitation clinics to effectively diagnose PF and to accurately monitor improvement in the disease process following rehabilitation interventions. Level of Evidence 1A PMID:27757279

  6. RF and microwave diagnostics of plasma

    International Nuclear Information System (INIS)

    Basu, J.

    1976-01-01

    A brief review of RF and microwave investigations carried out at laboratory plasma is presented. Both the immersive and non-immersive RF probes of various types are discussed, the major emphasis being laid on the work carried out in extending the scope of the immersive impedance probe and non-immersive coil probe. The standard microwave methods for plasma diagnosis are mentioned. The role of relatively new diagnostic tool, viz., a dielectric-rod waveguide, is described, and the technique of measuring the admittance of such a waveguide (or an antenna) enveloped in plasma is discussed. (K.B.)

  7. Practical tools to implement massive parallel pyrosequencing of PCR products in next generation molecular diagnostics.

    Directory of Open Access Journals (Sweden)

    Kim De Leeneer

    Full Text Available Despite improvements in terms of sequence quality and price per basepair, Sanger sequencing remains restricted to screening of individual disease genes. The development of massively parallel sequencing (MPS technologies heralded an era in which molecular diagnostics for multigenic disorders becomes reality. Here, we outline different PCR amplification based strategies for the screening of a multitude of genes in a patient cohort. We performed a thorough evaluation in terms of set-up, coverage and sequencing variants on the data of 10 GS-FLX experiments (over 200 patients. Crucially, we determined the actual coverage that is required for reliable diagnostic results using MPS, and provide a tool to calculate the number of patients that can be screened in a single run. Finally, we provide an overview of factors contributing to false negative or false positive mutation calls and suggest ways to maximize sensitivity and specificity, both important in a routine setting. By describing practical strategies for screening of multigenic disorders in a multitude of samples and providing answers to questions about minimum required coverage, the number of patients that can be screened in a single run and the factors that may affect sensitivity and specificity we hope to facilitate the implementation of MPS technology in molecular diagnostics.

  8. Auto fluorescence of intervertebral disc tissue: a new diagnostic tool.

    Science.gov (United States)

    Hoell, T; Huschak, G; Beier, A; Hüttmann, G; Minkus, Y; Holzhausen, H J; Meisel, H J

    2006-08-01

    The paper reports on auto fluorescence phenomena of inter-vertebral human discs. It systematically investigates the auto fluorescence effects of ex vivo disc specimen and reports on surgical cases to demonstrate the potential value of the new method. The paper offers biologic explanations of the phenomenon and discusses the potential value of the UV auto fluorescence technique as a diagnostic tool. Intra- and postoperative observations are made by a surgical microscope with an integrated UV light source. Quantitative measurements were carried out using a photon counter and a spectrometer ex vivo. The auto fluorescence phenomenon allows the differentiation of traumatized and degenerated disc tissue intraoperatively in some cases, it allows the differentiation of bony and collagen endplate in cervical disc surgery. The source of the auto fluorescent light emission are amino acids of the collagen molecules. The proteoglycan components and the liquid components of the disc do not show relevant auto fluorescence. Emission wavelength of disc material is equivalent to color perception. It differs due to different collagen composition of the intervertebral disc components from yellow-green to blue-green and can be visualized in situ by naked eye.UV-auto fluorescence of inter-vertebral discs is a new clinical tool that has the potential to differentiate disc material from the anatomical surrounding, to distinguish between different fractions of the disc and to give information on the quality and status of the disc material. Since the technology has just emerged, it needs further investigations to quantify the clinical observations reported in this paper.

  9. Medical Community of Inquiry: A Diagnostic Tool for Learning, Assessment, and Research

    Directory of Open Access Journals (Sweden)

    Rakefet Ackerman

    2017-01-01

    Full Text Available Aim/Purpose: These days educators are expected to integrate technological tools into classes. Although they acquire relevant skills, they are often reluctant to use these tools. Background:\tWe incorporated online forums for generating a Community of Inquiry (CoI in a faculty development program. Extending the Technology, Pedagogy, and Content Knowledge (TPACK model with Assessment Knowledge and content analysis of forum discourse and reflection after each CoI, we offer the Diagnostic Tool for Learning, Assessment, and Research (DTLAR. Methodology: This study spanned over two cycles of a development program for medical faculty. Contribution: This study demonstrates how the DTLAR supports in-depth examination of the benefits and challenges of using CoIs for learning and teaching. Findings: Before the program, participants had little experience with, and were reluctant to use, CoIs in classes. At the program completion, many were willing to adopt CoIs and appreciated this method’s contribution. Both CoIs discourse and reflections included positive attitudes regarding cognitive and teacher awareness categories. However, negative attitudes regarding affective aspects and time-consuming aspects of CoIs were exposed. Participants who experienced facilitating a CoI gained additional insights into its usefulness. Recommendations for Practitioners\t: The DTLAR allows analyzing adaption of online forums for learning and teaching. Recommendation for Researchers: The DTLAR allows analyzing factors that affect the acceptance of online fo-rums for learning and teaching. Impact on Society\t: While the tool was implemented in the context of medical education, it can be readily applied in other adult learning programs. Future Research: The study includes several design aspects that probably affected the improve-ment and challenges we found. Future research is called for providing guidelines for identifying boundary conditions and potential for further

  10. Creation of minimum standard tool for palliative care in India and self-evaluation of palliative care programs using it

    Directory of Open Access Journals (Sweden)

    M R Rajagopal

    2014-01-01

    Full Text Available Background: It is important to ensure that minimum standards for palliative care based on available resources are clearly defined and achieved. Aims: (1 Creation of minimum National Standards for Palliative Care for India. (2 Development of a tool for self-evaluation of palliative care organizations. (3 Evaluation of the tool in India. In 2006, Pallium India assembled a working group at the national level to develop minimum standards. The standards were to be evaluated by palliative care services in the country. Materials and Methods: The working group prepared a "standards" document, which had two parts - the first composed of eight "essential" components and the second, 22 "desirable" components. The working group sent the document to 86 hospice and palliative care providers nationwide, requesting them to self-evaluate their palliative care services based on the standards document, on a modified Likert scale. Results: Forty-nine (57% palliative care organizations responded, and their self-evaluation of services based on the standards tool was analyzed. The majority of the palliative care providers met most of the standards identified as essential by the working group. A variable percentage of organizations had satisfied the desirable components of the standards. Conclusions: We demonstrated that the "standards tool" could be applied effectively in practice for self-evaluation of quality of palliative care services.

  11. Establishing the standard X-ray beam qualities for calibration of dosimeters used in diagnostic radiology following IAEA-TRS457

    International Nuclear Information System (INIS)

    Duong Van Trieu; Ho Quang Tuan; Bui Duc Ky

    2014-01-01

    The determination of the patient dose needs to provide a reference dose for the patient that reference dose levels to assess the relative risk during X- ray diagnostic. This mission, We had established a number of standard beam qualities to perform calibrations of diagnostic dosimeters and methods of measuring patient dose in X-ray diagnostic. At radiation dosimetry room, we had establish RQR2, RQR3, RQR4, RQR5, RQR6 beam qualities based on IAEA-TRS457 documentation with homogeneity coefficient (h) for each beam quality in the range 0.7 - 0.8, and haft-value layers HVL1, HVL2 of experimental and IAEA is different about 10%. Established calibration method for diagnostic dosimeters as KAP meters, UNFORS dosimeters, and the TLD dosimeters, practical measurements of entrance surface air kerma on Shimadzu X-ray machines used phantom. (author)

  12. Sustainable development induction in organizations: a convergence analysis of ISO standards management tools' parameters.

    Science.gov (United States)

    Merlin, Fabrício Kurman; Pereira, Vera Lúciaduarte do Valle; Pacheco, Waldemar

    2012-01-01

    Organizations are part of an environment in which they are pressured to meet society's demands and acting in a sustainable way. In an attempt to meet such demands, organizations make use of various management tools, among which, ISO standards are used. Although there are evidences of contributions provided by these standards, it is questionable whether its parameters converge for a possible induction for sustainable development in organizations. This work presents a theoretical study, designed on structuralism world view, descriptive and deductive method, which aims to analyze the convergence of management tools' parameters in ISO standards. In order to support the analysis, a generic framework for possible convergence was developed, based on systems approach, linking five ISO standards (ISO 9001, ISO 14001, OHSAS 18001, ISO 31000 and ISO 26000) with sustainable development and positioning them according to organization levels (strategic, tactical and operational). The structure was designed based on Brundtland report concept. The analysis was performed exploring the generic framework for possible convergence based on Nadler and Tushman model. The results found the standards can contribute to a possible sustainable development induction in organizations, as long as they meet certain minimum conditions related to its strategic alignment.

  13. Prosthetic joint infection development of an evidence-based diagnostic algorithm.

    Science.gov (United States)

    Mühlhofer, Heinrich M L; Pohlig, Florian; Kanz, Karl-Georg; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; Kelch, Sarah; Harrasser, Norbert; von Eisenhart-Rothe, Rüdiger; Schauwecker, Johannes

    2017-03-09

    Increasing rates of prosthetic joint infection (PJI) have presented challenges for general practitioners, orthopedic surgeons and the health care system in the recent years. The diagnosis of PJI is complex; multiple diagnostic tools are used in the attempt to correctly diagnose PJI. Evidence-based algorithms can help to identify PJI using standardized diagnostic steps. We reviewed relevant publications between 1990 and 2015 using a systematic literature search in MEDLINE and PUBMED. The selected search results were then classified into levels of evidence. The keywords were prosthetic joint infection, biofilm, diagnosis, sonication, antibiotic treatment, implant-associated infection, Staph. aureus, rifampicin, implant retention, pcr, maldi-tof, serology, synovial fluid, c-reactive protein level, total hip arthroplasty (THA), total knee arthroplasty (TKA) and combinations of these terms. From an initial 768 publications, 156 publications were stringently reviewed. Publications with class I-III recommendations (EAST) were considered. We developed an algorithm for the diagnostic approach to display the complex diagnosis of PJI in a clear and logically structured process according to ISO 5807. The evidence-based standardized algorithm combines modern clinical requirements and evidence-based treatment principles. The algorithm provides a detailed transparent standard operating procedure (SOP) for diagnosing PJI. Thus, consistently high, examiner-independent process quality is assured to meet the demands of modern quality management in PJI diagnosis.

  14. Meta-analysis diagnostic accuracy of SNP-based pathogenicity detection tools: a case of UTG1A1 gene mutations.

    Science.gov (United States)

    Galehdari, Hamid; Saki, Najmaldin; Mohammadi-Asl, Javad; Rahim, Fakher

    2013-01-01

    Crigler-Najjar syndrome (CNS) type I and type II are usually inherited as autosomal recessive conditions that result from mutations in the UGT1A1 gene. The main objective of the present review is to summarize results of all available evidence on the accuracy of SNP-based pathogenicity detection tools compared to published clinical result for the prediction of in nsSNPs that leads to disease using prediction performance method. A comprehensive search was performed to find all mutations related to CNS. Database searches included dbSNP, SNPdbe, HGMD, Swissvar, ensemble, and OMIM. All the mutation related to CNS was extracted. The pathogenicity prediction was done using SNP-based pathogenicity detection tools include SIFT, PHD-SNP, PolyPhen2, fathmm, Provean, and Mutpred. Overall, 59 different SNPs related to missense mutations in the UGT1A1 gene, were reviewed. Comparing the diagnostic OR, PolyPhen2 and Mutpred have the highest detection 4.983 (95% CI: 1.24 - 20.02) in both, following by SIFT (diagnostic OR: 3.25, 95% CI: 1.07 - 9.83). The highest MCC of SNP-based pathogenicity detection tools, was belong to SIFT (34.19%) followed by Provean, PolyPhen2, and Mutpred (29.99%, 29.89%, and 29.89%, respectively). Hence the highest SNP-based pathogenicity detection tools ACC, was fit to SIFT (62.71%) followed by PolyPhen2, and Mutpred (61.02%, in both). Our results suggest that some of the well-established SNP-based pathogenicity detection tools can appropriately reflect the role of a disease-associated SNP in both local and global structures.

  15. EnergiTools(R) - a power plant performance monitoring and diagnosis tool

    International Nuclear Information System (INIS)

    Ancion, P.V.; Bastien, R.; Ringdahl, K.

    2000-01-01

    Westinghouse EnergiTools(R) is a performance diagnostic tool for power generation plants that combines the power of on-line process data acquisition with advanced diagnostics methodologies. The system uses analytical models based on thermodynamic principles combined with knowledge of component diagnostic experts. An issue in modeling expert knowledge is to have a framework that can represent and process uncertainty in complex systems. In such experiments, it is nearly impossible to build deterministic models for the effects of faults on symptoms. A methodology based on causal probabilistic graphs, more specifically on Bayesian belief networks, has been implemented in EnergiTools(R) to capture the fault-symptom relationships. The methodology estimates the likelihood of the various component failures using the fault-symptom relationships. The system also has the ability to use neural networks for processes that are difficult to model analytically. An application is the estimation of the reactor power in nuclear power plant by interpreting several plant indicators. EnergiTools(R) is used for the on-line performance monitoring and diagnostics at Vattenfall Ringhals nuclear power plants in Sweden. It has led to the diagnosis of various performance issues with plant components. Two case studies are presented. In the first case, an overestimate of the thermal power due to a faulty instrument was found, which led to a plant operation below its optimal power. The paper shows how the problem was discovered, using the analytical thermodynamic calculations. The second case shows an application of EnergiTools(R) for the diagnostic of a condenser failure using causal probabilistic graphs

  16. Power spectra as a diagnostic tool in probing statistical/nonstatistical behavior in unimolecular reactions

    Science.gov (United States)

    Chang, Xiaoyen Y.; Sewell, Thomas D.; Raff, Lionel M.; Thompson, Donald L.

    1992-11-01

    The possibility of utilizing different types of power spectra obtained from classical trajectories as a diagnostic tool to identify the presence of nonstatistical dynamics is explored by using the unimolecular bond-fission reactions of 1,2-difluoroethane and the 2-chloroethyl radical as test cases. In previous studies, the reaction rates for these systems were calculated by using a variational transition-state theory and classical trajectory methods. A comparison of the results showed that 1,2-difluoroethane is a nonstatistical system, while the 2-chloroethyl radical behaves statistically. Power spectra for these two systems have been generated under various conditions. The characteristics of these spectra are as follows: (1) The spectra for the 2-chloroethyl radical are always broader and more coupled to other modes than is the case for 1,2-difluoroethane. This is true even at very low levels of excitation. (2) When an internal energy near or above the dissociation threshold is initially partitioned into a local C-H stretching mode, the power spectra for 1,2-difluoroethane broaden somewhat, but discrete and somewhat isolated bands are still clearly evident. In contrast, the analogous power spectra for the 2-chloroethyl radical exhibit a near complete absence of isolated bands. The general appearance of the spectrum suggests a very high level of mode-to-mode coupling, large intramolecular vibrational energy redistribution (IVR) rates, and global statistical behavior. (3) The appearance of the power spectrum for the 2-chloroethyl radical is unaltered regardless of whether the initial C-H excitation is in the CH2 or the CH2Cl group. This result also suggests statistical behavior. These results are interpreted to mean that power spectra may be used as a diagnostic tool to assess the statistical character of a system. The presence of a diffuse spectrum exhibiting a nearly complete loss of isolated structures indicates that the dissociation dynamics of the molecule will

  17. Exhaust Gas Temperature Measurements in Diagnostics of Turbocharged Marine Internal Combustion Engines Part I Standard Measurements

    Directory of Open Access Journals (Sweden)

    Korczewski Zbigniew

    2015-01-01

    Full Text Available The article discusses the problem of diagnostic informativeness of exhaust gas temperature measurements in turbocharged marine internal combustion engines. Theoretical principles of the process of exhaust gas flow in turbocharger inlet channels are analysed in its dynamic and energetic aspects. Diagnostic parameters are defined which enable to formulate general evaluation of technical condition of the engine based on standard online measurements of the exhaust gas temperature. A proposal is made to extend the parametric methods of diagnosing workspaces in turbocharged marine engines by analysing time-histories of enthalpy changes of the exhaust gas flowing to the turbocompressor turbine. Such a time-history can be worked out based on dynamic measurements of the exhaust gas temperature, performed using a specially designed sheathed thermocouple.

  18. Wireless capsule endoscopy as a tool in diagnosing autoimmune enteropathy

    DEFF Research Database (Denmark)

    Gram-Kampmann, Eva-Marie; Lillevang, Søren T; Detlefsen, Sönke

    2015-01-01

    Autoimmune enteropathy (AE) is an immune mediated illness of the intestinal mucosa. The cause is unknown, and the diagnosis is based on typical characteristics displayed. There is no gold standard for treatment. We present two adult cases of AE and demonstrate the challenges in establishing....... Use of WCE as a diagnostic tool was invaluable in establishing the diagnosis of AE....

  19. Positivity of magnetic resonance imaging the GIROIMAG-01: Diagnostic tools in injuries of the central nervous system

    International Nuclear Information System (INIS)

    Noda Guerra, Manuel Ernesto; Corujo Torres, Pedro A.; Gonzalez Ferro, Idalia; Daudinot Gomez, Barbara; Montoya Pedron, Arquimedes

    2001-01-01

    A study was made to compare the positivity of magnetic resonance imaging with that of other imaging and neuropsychological diagnostic tools in injuries of the central nervous system in order to determine the sensitivity, specificity, strength and the test error with the GIROIMAG-01 Cuban tomograph in the diagnostic of these injuries. An intentional sample of 398 patients was selected. Only those patients who had undergone computed axial tomography, electroencephalogram or evoked multimodal potentials or both, whose results were registered in the study requests, could be selected. The most representative injuries among the diagnoses made were the degenerative diseases, the brain and cerebellar tumors, the cerebrovascular accidents, the demyelinizating diseases and hydrocephalous. It was demonstrated that this tomograph has an elevated sensitivity and specificity for the detection of injuries of the central nervous system

  20. Torsional vibration signal analysis as a diagnostic tool for planetary gear fault detection

    Science.gov (United States)

    Xue, Song; Howard, Ian

    2018-02-01

    This paper aims to investigate the effectiveness of using the torsional vibration signal as a diagnostic tool for planetary gearbox faults detection. The traditional approach for condition monitoring of the planetary gear uses a stationary transducer mounted on the ring gear casing to measure all the vibration data when the planet gears pass by with the rotation of the carrier arm. However, the time variant vibration transfer paths between the stationary transducer and the rotating planet gear modulate the resultant vibration spectra and make it complex. Torsional vibration signals are theoretically free from this modulation effect and therefore, it is expected to be much easier and more effective to diagnose planetary gear faults using the fault diagnostic information extracted from the torsional vibration. In this paper, a 20 degree of freedom planetary gear lumped-parameter model was developed to obtain the gear dynamic response. In the model, the gear mesh stiffness variations are the main internal vibration generation mechanism and the finite element models were developed for calculation of the sun-planet and ring-planet gear mesh stiffnesses. Gear faults on different components were created in the finite element models to calculate the resultant gear mesh stiffnesses, which were incorporated into the planetary gear model later on to obtain the faulted vibration signal. Some advanced signal processing techniques were utilized to analyses the fault diagnostic results from the torsional vibration. It was found that the planetary gear torsional vibration not only successfully detected the gear fault, but also had the potential to indicate the location of the gear fault. As a result, the planetary gear torsional vibration can be considered an effective alternative approach for planetary gear condition monitoring.

  1. The Unknown Oldowan: ~1.7-Million-Year-Old Standardized Obsidian Small Tools from Garba IV, Melka Kunture, Ethiopia.

    Directory of Open Access Journals (Sweden)

    Rosalia Gallotti

    Full Text Available The Oldowan Industrial Complex has long been thought to have been static, with limited internal variability, embracing techno-complexes essentially focused on small-to-medium flake production. The flakes were rarely modified by retouch to produce small tools, which do not show any standardized pattern. Usually, the manufacture of small standardized tools has been interpreted as a more complex behavior emerging with the Acheulean technology. Here we report on the ~1.7 Ma Oldowan assemblages from Garba IVE-F at Melka Kunture in the Ethiopian highland. This industry is structured by technical criteria shared by the other East African Oldowan assemblages. However, there is also evidence of a specific technical process never recorded before, i.e. the systematic production of standardized small pointed tools strictly linked to the obsidian exploitation. Standardization and raw material selection in the manufacture of small tools disappear at Melka Kunture during the Lower Pleistocene Acheulean. This proves that 1 the emergence of a certain degree of standardization in tool-kits does not reflect in itself a major step in cultural evolution; and that 2 the Oldowan knappers, when driven by functional needs and supported by a highly suitable raw material, were occasionally able to develop specific technical solutions. The small tool production at ~1.7 Ma, at a time when the Acheulean was already emerging elsewhere in East Africa, adds to the growing amount of evidence of Oldowan techno-economic variability and flexibility, further challenging the view that early stone knapping was static over hundreds of thousands of years.

  2. The Unknown Oldowan: ~1.7-Million-Year-Old Standardized Obsidian Small Tools from Garba IV, Melka Kunture, Ethiopia.

    Science.gov (United States)

    Gallotti, Rosalia; Mussi, Margherita

    2015-01-01

    The Oldowan Industrial Complex has long been thought to have been static, with limited internal variability, embracing techno-complexes essentially focused on small-to-medium flake production. The flakes were rarely modified by retouch to produce small tools, which do not show any standardized pattern. Usually, the manufacture of small standardized tools has been interpreted as a more complex behavior emerging with the Acheulean technology. Here we report on the ~1.7 Ma Oldowan assemblages from Garba IVE-F at Melka Kunture in the Ethiopian highland. This industry is structured by technical criteria shared by the other East African Oldowan assemblages. However, there is also evidence of a specific technical process never recorded before, i.e. the systematic production of standardized small pointed tools strictly linked to the obsidian exploitation. Standardization and raw material selection in the manufacture of small tools disappear at Melka Kunture during the Lower Pleistocene Acheulean. This proves that 1) the emergence of a certain degree of standardization in tool-kits does not reflect in itself a major step in cultural evolution; and that 2) the Oldowan knappers, when driven by functional needs and supported by a highly suitable raw material, were occasionally able to develop specific technical solutions. The small tool production at ~1.7 Ma, at a time when the Acheulean was already emerging elsewhere in East Africa, adds to the growing amount of evidence of Oldowan techno-economic variability and flexibility, further challenging the view that early stone knapping was static over hundreds of thousands of years.

  3. Using MALDI-TOF mass spectrometry as a rapid and accurate diagnostic tool in infective endocarditis: a case report of a patient with mitral valve infective endocarditis caused by Abiotrophia defectiva

    DEFF Research Database (Denmark)

    Holler, Jon Gitz; Pedersen, Line; Calum, Henrik

    2011-01-01

    A case of infective endocarditis caused by Abiotrophia defectiva is presented. The use of MALDI-TOF mass spectrometry as a rapid and accurate diagnostic tool in infective endocarditis is discussed.......A case of infective endocarditis caused by Abiotrophia defectiva is presented. The use of MALDI-TOF mass spectrometry as a rapid and accurate diagnostic tool in infective endocarditis is discussed....

  4. Summary of the dose assessment tool for diagnostic X-ray CT, WAZA-ARIv2

    International Nuclear Information System (INIS)

    Koba, Yosuke

    2016-01-01

    WAZA-ARIv2 is the web-based open system for the dose assessment for diagnostic X-ray CT. Amid growing interest about the dose assessment for medical exposure, WAZA-ARIv2 is opened to the public from January 2015 and attracts rising attention. Using WAZA-ARIv2 system, users can calculate exposure dose to consider patient's age and body shape, and can register the calculation results on WAZA-ARIv2 server for checking as histogram statistics. This paper reviews the background of development of WAZA-ARI system, the comparison of characteristics between WAZA-ARIv2 and other tools, and the calculation method of organ dose in WAZA-ARIv2. (author)

  5. Critical Pitfalls in the use of BRAF Mutation as a Diagnostic Tool in Thyroid Nodules: a Case Report.

    Science.gov (United States)

    Kuhn, Elisabetta; Ragazzi, Moira; Zini, Michele; Giordano, Davide; Nicoli, Davide; Piana, Simonetta

    2016-09-01

    Thyroid fine-needle aspiration (FNA) cytology is the primary tool for the diagnostic evaluation of thyroid nodules. BRAF mutation analysis is employed as an ancillary tool in indeterminate cases, as recommended by the American Thyroid Association management guidelines. Hereby, we report the case of a 73-year-old woman who presented an 8-mm-size, ill-defined, left thyroid nodule. FNA resulted "suspicious for papillary thyroid carcinoma". BRAF mutation status was analyzed, and somatic BRAF (V600E) mutation identified. The patient underwent a total thyroidectomy. At histological examination, the nodule was composed of Langerhans cells, admixed with many eosinophils. A final diagnosis of Langerhans cell histiocytosis of the thyroid was made. Our case emphasizes the critical diagnostic pitfalls due to the use of BRAF (V600E) mutation analysis in thyroid FNA. Notably, BRAF (V600E) mutation is common in melanoma, colorectal carcinoma, lung carcinoma, ovarian carcinoma, brain tumors, hairy cell leukemia, multiple myeloma, and histiocytoses. Therefore, in cases of indeterminate FNA with unclassifiable atypical cells BRAF (V600E) mutated, the possibility of a localization of hystiocytosis or a secondary thyroid malignancy should be taken into account.

  6. Laboratory diagnostics of malaria

    Science.gov (United States)

    Siahaan, L.

    2018-03-01

    Even now, malaria treatment should only be administered after laboratory confirmation. There are several principal methods for diagnosing malaria. All these methods have their disadvantages.Presumptive treatment of malaria is widely practiced where laboratory tests are not readily available. Microscopy of Giemsa-stained thick and thin blood films remains the gold standard for the diagnosis of malaria infection. The technique of slide preparation, staining and reading are well known and standardized, and so is the estimate of the parasite density and parasite stages. Microscopy is not always available or feasible at primary health services in limited resource settings due to cost, lack of skilled manpower, accessories and reagents required. Rapid diagnostic tests (RDTs) are potential tools for parasite-based diagnosis since the tests are accurate in detecting malaria infections and are easy to use. The test is based on the capture of parasite antigen that released from parasitized red blood cells using monoclonal antibodies prepared against malaria antigen target. Polymerase Chain Reaction (PCR), depend on DNA amplification approaches and have higher sensitivity than microscopy. PCR it is not widely used due to the lack of a standardized methodology, high costs, and the need for highly-trained staff.

  7. Incoherent Thomson scattering as a diagnostic tool

    NARCIS (Netherlands)

    Barth, C. J.

    1998-01-01

    Thomson scattering is a very powerful diagnostic which is applied at nearly every magnetic confinement device. Depending on the experimental conditions different plasma parameters can be diagnosed. When the wavelength is much smaller than the plasma Debye length, the total scattered power is

  8. Prevalence of pain and relative diagnostic performance of screening tools for neuropathic pain in cancer patients: A cross-sectional study.

    Science.gov (United States)

    Pérez, C; Sánchez-Martínez, N; Ballesteros, A; Blanco, T; Collazo, A; González, F; Villoria, J

    2015-07-01

    Neuropathic pain can be overlooked in cancer patients. The advent of screening tools can help in recognizing it. However, little is known about their relative diagnostic performance and factors that affect it. This study evaluated the prevalence of neuropathic pain using several diagnostic strategies in cancer patients undergoing chemotherapy. Patients attending the Oncology Unit of the investigators' site to continue their chemotherapy schedule were systematically screened for this cross-sectional study. Before starting chemotherapy drugs, pain specialists made a clinical diagnosis of neuropathic pain (either disease related, treatment related or comorbid) and medical oncologists administered three validated screening tools. Their relative diagnostic performance and the impact of some pain features on it were analysed using multivariate statistical methods. From a total of 358 patients, 194 (54.2%) suffered from pain and 73 (20.4%) had a clinical diagnosis of pure neuropathic or mixed pain. Among the screening tools, the Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) was more specific (93.4%), although less sensitive (68.1%) than the Douleur Neuropathique in 4 Questions (DN4) (sensitivity: 87.5%, specificity: 88.4%). Interestingly, the specificities of these two instruments did not differ in patients with mild pain, while the DN4 remained to be more sensitive than the LANSS regardless of pain severity. Neuropathic pain is common in cancer patients undergoing chemotherapy. The DN4 might be of great help for the early detection of patients at risk because of incipient chemotherapy-related neuropathies and the LANSS to rule out neuropathic pain in patients with complex pain conditions. © 2014 The Authors. European Journal of Pain published by John Wiley & Sons Ltd on behalf of European Pain Federation - EFIC®.

  9. [Polish version of the ADOS (autism diagnostic observation schedule-generic)].

    Science.gov (United States)

    Chojnicka, Izabela; Płoski, Rafał

    2012-01-01

    The article presents the Polish version of the autism diagnostic observation schedule-generic (ADOS), which together with the autism diagnostic interview-revised (ADI-R) is cited as the "gold standard" for the diagnosis of autism. The ADOS is a standardised, semistructured observation protocol appropriate for children and adults of differing age and language levels. It is linked to ICD-10 and DSM-IV-TR criteria. The ADOS consists of four modules, ranging from module 1 for nonverbal individuals to module 4 for verbally fluent adults. The adequate inter-rater reliability for items has been established. The protocol has high discriminant validity and distinguishes children with pervasive developmental disorders from children, who are outside of the spectrum. Although it does not enable to distinguish individuals with pervasive developmental disorder, unspecified from individuals with childhood autism. The paper presents subsequent steps of the translation process of the original version into Polish, as well as a chosen adaptation strategy of the Polish version. The ADOS is a very useful tool both for clinical diagnosis and for the scientific purpose diagnosis. In this last case it is extremely important to use a standardised method. Until now, there was no standardised diagnostic tool for autism in Poland.

  10. Diagnostic Tools of Pleural Effusion

    Science.gov (United States)

    2014-01-01

    Pleural effusion is not a rare disease in Korea. The diagnosis of pleural effusion is very difficult, even though the patients often complain of typical symptoms indicating of pleural diseases. Pleural effusion is characterized by the pleural cavity filled with transudative or exudative pleural fluids, and it is developed by various etiologies. The presence of pleural effusion can be confirmed by radiological studies including simple chest radiography, ultrasonography, or computed tomography. Identifying the causes of pleural effusions by pleural fluid analysis is essential for proper treatments. This review article provides information on the diagnostic approaches of pleural effusions and further suggested ways to confirm their various etiologies, by using the most recent journals for references. PMID:24920946

  11. Vibrational spectroscopy: a clinical tool for cancer diagnostics.

    Science.gov (United States)

    Kendall, Catherine; Isabelle, Martin; Bazant-Hegemark, Florian; Hutchings, Joanne; Orr, Linda; Babrah, Jaspreet; Baker, Rebecca; Stone, Nicholas

    2009-06-01

    Vibrational spectroscopy techniques have demonstrated potential to provide non-destructive, rapid, clinically relevant diagnostic information. Early detection is the most important factor in the prevention of cancer. Raman and infrared spectroscopy enable the biochemical signatures from biological tissues to be extracted and analysed. In conjunction with advanced chemometrics such measurements can contribute to the diagnostic assessment of biological material. This paper also illustrates the complementary advantage of using Raman and FTIR spectroscopy technologies together. Clinical requirements are increasingly met by technological developments which show promise to become a clinical reality. This review summarises recent advances in vibrational spectroscopy and their impact on the diagnosis of cancer.

  12. Medical thoracoscopy: a useful diagnostic tool for undiagnosed pleural effusion.

    Science.gov (United States)

    Agarwal, Abhishek; Prasad, Rajendra; Garg, Rajiv; Verma, S K; Singh, Abhijeet; Husain, N

    2014-01-01

    We aimed to assess the role of medical thoracoscopy in patients with undiagnosed pleural effusion. Patiens presenting with pleural effusion underwent three pleural aspirations. Patients in whom pleural fluid analysis was inconclusive underwent closed pleural biopsy for diagnostic confirmation. Patients in whom closed pleural biopsy was incolcusive underwent medical thoracoscopy using a rigid thoracoscope with a viewing angle of zero degrees was done under local anaesthesia and sedation with the patient lying in lateral decubitus position with the affected side up. Biopsy specimens from parietal pleura were obtained under direct vision and were sent for histopathological examination. Of the 128 patients with pleural effusion who were studied, pleural fluid examination established the diagnosis in 81 (malignancy 33, tuberculosis 33, pyogenic 14 and fungal 1); 47 patients underwent closed pleural biopsy and a diagnosis was made in 28 patients (malignancy 24, tuberculosis 4). The remaining 19 patients underwent medical thoracoscopy and pleural biopsy and the aetiological diagnosis could be confirmed in 13 of the 19 patients (69%) (adenocarcinoma 10, poorly differentiated carcinoma 2 and mesothelioma 1). Medical thoracoscopy is a useful tool for the diagnosis of pleural diseases. The procedure is safe with minimal complications.

  13. Use of standardized multidimensional evaluation tools and the emergence of the case manager's professional identity in France.

    Science.gov (United States)

    Nugue, Mathilde; De Stampa, Matthieu; Couturier, Yves; Somme, Dominique

    2012-01-01

    In France, the national public health plan proposes a group of innovations including the initiation of case management for older adults in complex situations, particularly those with cognitive disorders. In this context, public authorities asked case managers to use a standardized multidimensional evaluation tool. The results of a qualitative study on the pertinence of such a tool relative to the emergence of this new professional field are described. Early use of an evaluation tool seems to be linked to the emergence of a new professional identity for recently recruited case managers. Factors determining the strength of this link are training tool standardization, computerization, and local structure's involvement. Our results contribute to identifying one of the ways by which professional identity can be changed to become a case manager.

  14. Partial verification bias and incorporation bias affected accuracy estimates of diagnostic studies for biomarkers that were part of an existing composite gold standard.

    Science.gov (United States)

    Karch, Annika; Koch, Armin; Zapf, Antonia; Zerr, Inga; Karch, André

    2016-10-01

    To investigate how choice of gold standard biases estimates of sensitivity and specificity in studies reassessing the diagnostic accuracy of biomarkers that are already part of a lifetime composite gold standard (CGS). We performed a simulation study based on the real-life example of the biomarker "protein 14-3-3" used for diagnosing Creutzfeldt-Jakob disease. Three different types of gold standard were compared: perfect gold standard "autopsy" (available in a small fraction only; prone to partial verification bias), lifetime CGS (including the biomarker under investigation; prone to incorporation bias), and "best available" gold standard (autopsy if available, otherwise CGS). Sensitivity was unbiased when comparing 14-3-3 with autopsy but overestimated when using CGS or "best available" gold standard. Specificity of 14-3-3 was underestimated in scenarios comparing 14-3-3 with autopsy (up to 24%). In contrast, overestimation (up to 20%) was observed for specificity compared with CGS; this could be reduced to 0-10% when using the "best available" gold standard. Choice of gold standard affects considerably estimates of diagnostic accuracy. Using the "best available" gold standard (autopsy where available, otherwise CGS) leads to valid estimates of specificity, whereas sensitivity is estimated best when tested against autopsy alone. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. A New Browser-based, Ontology-driven Tool for Generating Standardized, Deep Descriptions of Geoscience Models

    Science.gov (United States)

    Peckham, S. D.; Kelbert, A.; Rudan, S.; Stoica, M.

    2016-12-01

    Standardized metadata for models is the key to reliable and greatly simplified coupling in model coupling frameworks like CSDMS (Community Surface Dynamics Modeling System). This model metadata also helps model users to understand the important details that underpin computational models and to compare the capabilities of different models. These details include simplifying assumptions on the physics, governing equations and the numerical methods used to solve them, discretization of space (the grid) and time (the time-stepping scheme), state variables (input or output), model configuration parameters. This kind of metadata provides a "deep description" of a computational model that goes well beyond other types of metadata (e.g. author, purpose, scientific domain, programming language, digital rights, provenance, execution) and captures the science that underpins a model. While having this kind of standardized metadata for each model in a repository opens up a wide range of exciting possibilities, it is difficult to collect this information and a carefully conceived "data model" or schema is needed to store it. Automated harvesting and scraping methods can provide some useful information, but they often result in metadata that is inaccurate or incomplete, and this is not sufficient to enable the desired capabilities. In order to address this problem, we have developed a browser-based tool called the MCM Tool (Model Component Metadata) which runs on notebooks, tablets and smart phones. This tool was partially inspired by the TurboTax software, which greatly simplifies the necessary task of preparing tax documents. It allows a model developer or advanced user to provide a standardized, deep description of a computational geoscience model, including hydrologic models. Under the hood, the tool uses a new ontology for models built on the CSDMS Standard Names, expressed as a collection of RDF files (Resource Description Framework). This ontology is based on core concepts

  16. Toward an Attention-Based Diagnostic Tool for Patients With Locked-in Syndrome.

    Science.gov (United States)

    Lesenfants, Damien; Habbal, Dina; Chatelle, Camille; Soddu, Andrea; Laureys, Steven; Noirhomme, Quentin

    2018-03-01

    Electroencephalography (EEG) has been proposed as a supplemental tool for reducing clinical misdiagnosis in severely brain-injured populations helping to distinguish conscious from unconscious patients. We studied the use of spectral entropy as a measure of focal attention in order to develop a motor-independent, portable, and objective diagnostic tool for patients with locked-in syndrome (LIS), answering the issues of accuracy and training requirement. Data from 20 healthy volunteers, 6 LIS patients, and 10 patients with a vegetative state/unresponsive wakefulness syndrome (VS/UWS) were included. Spectral entropy was computed during a gaze-independent 2-class (attention vs rest) paradigm, and compared with EEG rhythms (delta, theta, alpha, and beta) classification. Spectral entropy classification during the attention-rest paradigm showed 93% and 91% accuracy in healthy volunteers and LIS patients respectively. VS/UWS patients were at chance level. EEG rhythms classification reached a lower accuracy than spectral entropy. Resting-state EEG spectral entropy could not distinguish individual VS/UWS patients from LIS patients. The present study provides evidence that an EEG-based measure of attention could detect command-following in patients with severe motor disabilities. The entropy system could detect a response to command in all healthy subjects and LIS patients, while none of the VS/UWS patients showed a response to command using this system.

  17. Visual operations management tools applied to the oil pipelines and terminals standardization process: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the process by which visual operations management (VOM) tools were implemented, concerning standards and operational procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. It provides: a brief literature review of visual operations management tools applied to total quality management and the standardization processes; a discussion of the assumptions from the second level of VOM (visual standards) upon which TRANSPETRO's oil pipelines and terminals business processes and operational procedures are based; and a description of the VOM implementation process involving more than 100 employees and one illustrative example of 'Quick Guides' for right-of- way management activities. Finally, it discusses the potential impacts and benefits of using VOM tools in the current practices in TRANSPETRO's Oil Pipelines and Terminals Unit, reinforcing the importance of such visual guides as vital to implement regional and corporate procedures, focusing on the main operational processes. (author)

  18. Estimation of Sensitivity and Specificity of Three Conditionally Dependent Diagnostic Tests in the Absence of a Gold Standard

    NARCIS (Netherlands)

    Engel, B.; Swildens, B.; Stegeman, J.A.; Buist, W.G.; Jong, de M.

    2006-01-01

    This article presents a model to evaluate the accuracy of diagnostic tests. Data from three tests for the detection of EF-positive Streptococcus suis serotype 2 strains in sows were analyzed. The data were collected in a field study in the absence of a gold standard, that is, the true disease status

  19. Salivary cortisol as a tool for physiological studies and diagnostic strategies

    Directory of Open Access Journals (Sweden)

    Castro M.

    2000-01-01

    Full Text Available Salivary cortisol is an index of plasma free cortisol and is obtained by a noninvasive procedure. We have been using salivary cortisol as a tool for physiological and diagnostic studies, among them the emergence of circadian rhythm in preterm and term infants. The salivary cortisol circadian rhythm in term and premature infants was established between 8 and 12 postnatal weeks. In the preterm infants the emergence of circadian rhythm was parallel to the onset of sleep rhythm. We also studied the use of salivary cortisol for screening for Cushing's syndrome (CS in control and obese outpatients based on circadian rhythm and the overnight 1 mg dexamethasone (DEX suppression test. Salivary cortisol was suppressed to less than 100 ng/dl after 1 mg DEX in control and obese patients. A single salivary cortisol measurement at 23:00 h and again after 1 mg DEX above the 90th percentile of the obese group values had sensitivity and specificity of 93 and 93% (23:00 h, and 91 and 94% (after DEX, respectively. The sensitivity improved to 100% when we combined both parameters. We also studied 11 CS children and 21 age-matched primary obese children for whom salivary cortisol sensitivity and specificity were 100/95% (23:00 h, and 100/95% (1 mg DEX, respectively. Similar to adults, sensitivity and specificity of 100% were obtained by combining 23:00 h and 1 mg DEX. The measurement of salivary cortisol is a useful tool for physiological studies and for the diagnosis of CS in children and adults on an outpatient basis.

  20. Digitized molecular diagnostics: reading disk-based bioassays with standard computer drives.

    Science.gov (United States)

    Li, Yunchao; Ou, Lily M L; Yu, Hua-Zhong

    2008-11-01

    We report herein a digital signal readout protocol for screening disk-based bioassays with standard optical drives of ordinary desktop/notebook computers. Three different types of biochemical recognition reactions (biotin-streptavidin binding, DNA hybridization, and protein-protein interaction) were performed directly on a compact disk in a line array format with the help of microfluidic channel plates. Being well-correlated with the optical darkness of the binding sites (after signal enhancement by gold nanoparticle-promoted autometallography), the reading error levels of prerecorded audio files can serve as a quantitative measure of biochemical interaction. This novel readout protocol is about 1 order of magnitude more sensitive than fluorescence labeling/scanning and has the capability of examining multiplex microassays on the same disk. Because no modification to either hardware or software is needed, it promises a platform technology for rapid, low-cost, and high-throughput point-of-care biomedical diagnostics.

  1. Quality control in diagnostic immunohistochemistry: integrated on-slide positive controls.

    Science.gov (United States)

    Bragoni, A; Gambella, A; Pigozzi, S; Grigolini, M; Fiocca, R; Mastracci, L; Grillo, F

    2017-11-01

    Standardization in immunohistochemistry is a priority in modern pathology and requires strict quality control. Cost containment has also become fundamental and auditing of all procedures must take into account both these principles. Positive controls must be routinely performed so that their positivity guarantees the appropriateness of the immunohistochemical procedure. The aim of this study is to develop a low cost (utilizing a punch biopsy-PB-tool) procedure to construct positive controls which can be integrated in the patient's tissue slide. Sixteen frequently used control blocks were selected and multiple cylindrical samples were obtained using a 5-mm diameter punch biopsy tool, separately re-embedding them in single blocks. For each diagnostic immunoreaction requiring a positive control, an integrated PB-control section (cut from the appropriate PB-control block) was added to the top right corner of the diagnostic slide before immunostaining. This integrated control technique permitted a saving of 4.75% in total direct lab costs and proved to be technically feasible and reliable. Our proposal is easy to perform and within the reach of all pathology labs, requires easily available tools, its application costs is less than using external paired controls and ensures that a specific control for each slide is always available.

  2. Ultraviolet-visible and fluorescence spectroscopy can be used as a diagnostic tool for gamma irradiation detection in vivo.

    Science.gov (United States)

    K-Abdelhalim, Mohamed Anwar; Moussa, Sherif A-Abdelmottaleb

    2016-09-01

    The spectroscopic properties can indicate important features about the nature and severity of the disease. However, no earlier studies have been used the spectroscopic properties as a diagnostic tool for radiation detection. This study was aimed to use ultraviolet-visible and fluorescence spectroscopy as a diagnostic tool for gamma irradiation detection in rats in vivo. Adult male rats were exposed to 25, 50, 75 and 100 Gray as single dose, using Cobalt-60 (Co-60) source with a dose rate of 0.883 centi Gray/sec (cGy/s). Ultraviolet and fluorescence spectroscopy of rat's blood serum were measured. After gamma irradiation of rats in vivo, the blood serum absorbance peaks for 25, 50, 75 and 100 Gray (Gy) decreased and shifted towards the ultra violet wavelength. A maximal change in fluorescence intensity of blood serum at 350 nm was obtained when exciting light at 194 nm after irradiation. The fluorescence intensity also decreased with the dose. The highest radiation gamma dose might be accompanied with the highest oxidative stress. This study suggests that at the above mentioned gamma radiation doses, the blood is highly fragmented; with low aggregation at 25 Gy and with high aggregation at 50-100 Gy.

  3. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    Energy Technology Data Exchange (ETDEWEB)

    Fallahi, Farshid [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom); North Cumbria University Hospitals, Department of Radiology, Carlisle (United Kingdom); Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom)

    2013-09-15

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  4. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    International Nuclear Information System (INIS)

    Fallahi, Farshid; Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon

    2013-01-01

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  5. Building Accessible Educational Web Sites: The Law, Standards, Guidelines, Tools, and Lessons Learned

    Science.gov (United States)

    Liu, Ye; Palmer, Bart; Recker, Mimi

    2004-01-01

    Professional education is increasingly facing accessibility challenges with the emergence of webbased learning. This paper summarizes related U.S. legislation, standards, guidelines, and validation tools to make web-based learning accessible for all potential learners. We also present lessons learned during the implementation of web accessibility…

  6. GAMBIT: the global and modular beyond-the-standard-model inference tool

    Science.gov (United States)

    Athron, Peter; Balazs, Csaba; Bringmann, Torsten; Buckley, Andy; Chrząszcz, Marcin; Conrad, Jan; Cornell, Jonathan M.; Dal, Lars A.; Dickinson, Hugh; Edsjö, Joakim; Farmer, Ben; Gonzalo, Tomás E.; Jackson, Paul; Krislock, Abram; Kvellestad, Anders; Lundberg, Johan; McKay, James; Mahmoudi, Farvah; Martinez, Gregory D.; Putze, Antje; Raklev, Are; Ripken, Joachim; Rogan, Christopher; Saavedra, Aldo; Savage, Christopher; Scott, Pat; Seo, Seon-Hee; Serra, Nicola; Weniger, Christoph; White, Martin; Wild, Sebastian

    2017-11-01

    We describe the open-source global fitting package GAMBIT: the Global And Modular Beyond-the-Standard-Model Inference Tool. GAMBIT combines extensive calculations of observables and likelihoods in particle and astroparticle physics with a hierarchical model database, advanced tools for automatically building analyses of essentially any model, a flexible and powerful system for interfacing to external codes, a suite of different statistical methods and parameter scanning algorithms, and a host of other utilities designed to make scans faster, safer and more easily-extendible than in the past. Here we give a detailed description of the framework, its design and motivation, and the current models and other specific components presently implemented in GAMBIT. Accompanying papers deal with individual modules and present first GAMBIT results. GAMBIT can be downloaded from gambit.hepforge.org.

  7. GAMBIT. The global and modular beyond-the-standard-model inference tool

    Energy Technology Data Exchange (ETDEWEB)

    Athron, Peter; Balazs, Csaba [Monash University, School of Physics and Astronomy, Melbourne, VIC (Australia); Australian Research Council Centre of Excellence for Particle Physics at the Tera-scale (Australia); Bringmann, Torsten; Dal, Lars A.; Gonzalo, Tomas E.; Krislock, Abram; Raklev, Are [University of Oslo, Department of Physics, Oslo (Norway); Buckley, Andy [University of Glasgow, SUPA, School of Physics and Astronomy, Glasgow (United Kingdom); Chrzaszcz, Marcin [Universitaet Zuerich, Physik-Institut, Zurich (Switzerland); Polish Academy of Sciences, H. Niewodniczanski Institute of Nuclear Physics, Krakow (Poland); Conrad, Jan; Edsjoe, Joakim; Farmer, Ben; Lundberg, Johan [AlbaNova University Centre, Oskar Klein Centre for Cosmoparticle Physics, Stockholm (Sweden); Stockholm University, Department of Physics, Stockholm (Sweden); Cornell, Jonathan M. [McGill University, Department of Physics, Montreal, QC (Canada); Dickinson, Hugh [University of Minnesota, Minnesota Institute for Astrophysics, Minneapolis, MN (United States); Jackson, Paul; White, Martin [Australian Research Council Centre of Excellence for Particle Physics at the Tera-scale (Australia); University of Adelaide, Department of Physics, Adelaide, SA (Australia); Kvellestad, Anders; Savage, Christopher [NORDITA, Stockholm (Sweden); McKay, James [Imperial College London, Blackett Laboratory, Department of Physics, London (United Kingdom); Mahmoudi, Farvah [Univ Lyon, Univ Lyon 1, ENS de Lyon, CNRS, Centre de Recherche Astrophysique de Lyon UMR5574, Saint-Genis-Laval (France); CERN, Theoretical Physics Department, Geneva (Switzerland); Martinez, Gregory D. [University of California, Physics and Astronomy Department, Los Angeles, CA (United States); Putze, Antje [LAPTh, Universite de Savoie, CNRS, Annecy-le-Vieux (France); Ripken, Joachim [Max Planck Institute for Solar System Research, Goettingen (Germany); Rogan, Christopher [Harvard University, Department of Physics, Cambridge, MA (United States); Saavedra, Aldo [Australian Research Council Centre of Excellence for Particle Physics at the Tera-scale (Australia); The University of Sydney, Faculty of Engineering and Information Technologies, Centre for Translational Data Science, School of Physics, Sydney, NSW (Australia); Scott, Pat [Imperial College London, Blackett Laboratory, Department of Physics, London (United Kingdom); Seo, Seon-Hee [Seoul National University, Department of Physics and Astronomy, Seoul (Korea, Republic of); Serra, Nicola [Universitaet Zuerich, Physik-Institut, Zurich (Switzerland); Weniger, Christoph [University of Amsterdam, GRAPPA, Institute of Physics, Amsterdam (Netherlands); Wild, Sebastian [DESY, Hamburg (Germany); Collaboration: The GAMBIT Collaboration

    2017-11-15

    We describe the open-source global fitting package GAMBIT: the Global And Modular Beyond-the-Standard-Model Inference Tool. GAMBIT combines extensive calculations of observables and likelihoods in particle and astroparticle physics with a hierarchical model database, advanced tools for automatically building analyses of essentially any model, a flexible and powerful system for interfacing to external codes, a suite of different statistical methods and parameter scanning algorithms, and a host of other utilities designed to make scans faster, safer and more easily-extendible than in the past. Here we give a detailed description of the framework, its design and motivation, and the current models and other specific components presently implemented in GAMBIT. Accompanying papers deal with individual modules and present first GAMBIT results. GAMBIT can be downloaded from gambit.hepforge.org. (orig.)

  8. GAMBIT. The global and modular beyond-the-standard-model inference tool

    International Nuclear Information System (INIS)

    Athron, Peter; Balazs, Csaba; Bringmann, Torsten; Dal, Lars A.; Gonzalo, Tomas E.; Krislock, Abram; Raklev, Are; Buckley, Andy; Chrzaszcz, Marcin; Conrad, Jan; Edsjoe, Joakim; Farmer, Ben; Lundberg, Johan; Cornell, Jonathan M.; Dickinson, Hugh; Jackson, Paul; White, Martin; Kvellestad, Anders; Savage, Christopher; McKay, James; Mahmoudi, Farvah; Martinez, Gregory D.; Putze, Antje; Ripken, Joachim; Rogan, Christopher; Saavedra, Aldo; Scott, Pat; Seo, Seon-Hee; Serra, Nicola; Weniger, Christoph; Wild, Sebastian

    2017-01-01

    We describe the open-source global fitting package GAMBIT: the Global And Modular Beyond-the-Standard-Model Inference Tool. GAMBIT combines extensive calculations of observables and likelihoods in particle and astroparticle physics with a hierarchical model database, advanced tools for automatically building analyses of essentially any model, a flexible and powerful system for interfacing to external codes, a suite of different statistical methods and parameter scanning algorithms, and a host of other utilities designed to make scans faster, safer and more easily-extendible than in the past. Here we give a detailed description of the framework, its design and motivation, and the current models and other specific components presently implemented in GAMBIT. Accompanying papers deal with individual modules and present first GAMBIT results. GAMBIT can be downloaded from gambit.hepforge.org. (orig.)

  9. Visual operations management tools applied to the oil pipelines and terminals standardization process: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the process by which visual operations management (VOM) tools were implemented, concerning standards and operational procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. It provides: a brief literature review of visual operations management tools applied to total quality management and the standardization processes; a discussion of the assumptions from the second level of VOM (visual standards) upon which TRANSPETRO's oil pipelines and terminals business processes and operational procedures are based; and a description of the VOM implementation process involving more than 100 employees and one illustrative example of 'Quick Guides' for right-of- way management activities. Finally, it discusses the potential impacts and benefits of using VOM tools in the current practices in TRANSPETRO's Oil Pipelines and Terminals Unit, reinforcing the importance of such visual guides as vital to implement regional and corporate procedures, focusing on the main operational processes. (author)

  10. Diagnostic Development on NSTX

    International Nuclear Information System (INIS)

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-01-01

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted

  11. ADHD and Present Hedonism: time perspective as a potential diagnostic and therapeutic tool.

    Science.gov (United States)

    Weissenberger, S; Klicperova-Baker, M; Zimbardo, P; Schonova, K; Akotia, D; Kostal, J; Goetz, M; Raboch, J; Ptacek, R

    2016-01-01

    The article draws primarily from the behavioral findings (mainly psychiatric and psychological observations) and points out the important relationships between attention-deficit/hyperactivity disorder (ADHD) symptoms and time orientation. Specifically, the authors argue that there is a significant overlap between the symptoms of ADHD and Present Hedonism. Present Hedonism is defined by Zimbardo's time perspective theory and assessed by Zimbardo Time Perspective Inventory. Developmental data on Present Hedonism of males and females in the Czech population sample (N=2201) are also presented. The hypothesis of relationship between ADHD and Present Hedonism is mainly derived from the prevalence of addictive behavior (mainly excessive Internet use, alcohol abuse, craving for sweets, fatty foods, and fast foods), deficits in social learning, and increased aggressiveness both in ADHD and in the population scoring high on Present Hedonism in the Zimbardo Time Perspective Inventory. We conclude that Zimbardo's time perspective offers both: 1) a potential diagnostic tool - the Zimbardo Time Perspective Inventory, particularly its Present Hedonism scale, and 2) a promising preventive and/or therapeutic approach by the Time Perspective Therapy. Time Perspective Therapy has so far been used mainly to treat past negative trauma (most notably, posttraumatic stress disorder); however, it also has value as a potential therapeutic tool for possible behavioral compensation of ADHD.

  12. Videofluoroscopy versus upper G.I. endoscopy: A comparative study as a diagnostic tool in patients presenting with dysphagia

    OpenAIRE

    Sharwak Ramlan; Sai Manohar; Gangadhara Somayaji

    2015-01-01

    Background and Objective: Dysphagia is a major symptom in many of the patients coming to the hospital. There can be various causes of dysphagia and its accurate diagnosis shows the way for the necessary treatment. Videofluoroscopy and upper gastrointestinal (GI) endoscopy are the two most commonly employed primary investigating modalities in assessing dysphagia. The objective of the study was to compare videofluoroscopy and upper GI endoscopy and establish a primary diagnostic tool for assess...

  13. Application of the denaturing gradient gel electrophoresis (DGGE) technique as an efficient diagnostic tool for ciliate communities in soil

    OpenAIRE

    Jousset, Alexandre; Lara, Enrique; Nikolausz, Marcell; Harms, Hauke; Chatzinotasa, Antonis

    2010-01-01

    Ciliates (or Ciliophora) are ubiquitous organisms which can be widely used as bioindicators in ecosystems exposed to anthropogenic and industrial influences. The evaluation of the environmental impact on soil ciliate communities with methods relying on morphology-based identification may be hampered by the large number of samples usually required for a statistically supported, reliable conclusion. Cultivation-independent molecular-biological diagnostic tools are a promising alternative to gre...

  14. [Intelligent systems tools in the diagnosis of acute coronary syndromes: A systemic review].

    Science.gov (United States)

    Sprockel, John; Tejeda, Miguel; Yate, José; Diaztagle, Juan; González, Enrique

    2017-03-27

    Acute myocardial infarction is the leading cause of non-communicable deaths worldwide. Its diagnosis is a highly complex task, for which modelling through automated methods has been attempted. A systematic review of the literature was performed on diagnostic tests that applied intelligent systems tools in the diagnosis of acute coronary syndromes. A systematic review of the literature is presented using Medline, Embase, Scopus, IEEE/IET Electronic Library, ISI Web of Science, Latindex and LILACS databases for articles that include the diagnostic evaluation of acute coronary syndromes using intelligent systems. The review process was conducted independently by 2 reviewers, and discrepancies were resolved through the participation of a third person. The operational characteristics of the studied tools were extracted. A total of 35 references met the inclusion criteria. In 22 (62.8%) cases, neural networks were used. In five studies, the performances of several intelligent systems tools were compared. Thirteen studies sought to perform diagnoses of all acute coronary syndromes, and in 22, only infarctions were studied. In 21 cases, clinical and electrocardiographic aspects were used as input data, and in 10, only electrocardiographic data were used. Most intelligent systems use the clinical context as a reference standard. High rates of diagnostic accuracy were found with better performance using neural networks and support vector machines, compared with statistical tools of pattern recognition and decision trees. Extensive evidence was found that shows that using intelligent systems tools achieves a greater degree of accuracy than some clinical algorithms or scales and, thus, should be considered appropriate tools for supporting diagnostic decisions of acute coronary syndromes. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  15. Laparohysteroscopy in female infertility: A diagnostic cum therapeutic tool in Indian setting.

    Science.gov (United States)

    Puri, Suman; Jain, Dinesh; Puri, Sandeep; Kaushal, Sandeep; Deol, Satjeet Kaur

    2015-01-01

    To evaluate the role of laparohysteroscopy in female infertility andto study the effect of therapeutic procedures in achieving fertility. Patients with female infertility presenting to outpatient Department of Obstetrics and Gynecology were evaluated over a period of 18 months. Fifty consenting subjects excluding male factor infertility with normal hormonal profile and no contraindication to laparoscopy were subject to diagnostic laparoscopy and hysteroscopy. T-test. We studied 50 patients comprising of 24 (48%) cases of primary infertility and 26 (52%) patients of secondary infertility. The average age of active married life for 50 patients was between 8 and 9 years. In our study, the most commonly found pathologies were PCOD, endometroisis and tubal blockage. 11 (28.2) patients conceived after laparohysteroscopy followed by artificial reproductive techniques. This study demonstrates the benefit of laparohysteroscopy for diagnosis and as a therapeutic tool in patients with primary and secondary infertility. We were able to achieve a higher conception rate of 28.2%.

  16. Regulatory T cell derived Exosomes: possible therapeutic and diagnostic tools in transplantation

    Directory of Open Access Journals (Sweden)

    Akansha eAgarwal

    2014-11-01

    Full Text Available Exosomes are extracellular vesicles released by many cells of the body. These small vesicles play an important part in intercellular communication both in the local environment and systemically, facilitating in the transfer of proteins, cytokines as well as miRNA between cells. The observation that exosomes isolated from immune cells such as dendritic cells (DCs modulate the immune response has paved the way for these structures to be considered as potential immunotherapeutic reagents. Indeed clinical trials using DC derived exosomes to facilitate immune responses to specific cancer antigens are now underway. Exosomes can also have a negative effect on the immune response and exosomes isolated from regulatory T cells (Tregs and other subsets of T cells have been shown to have immune suppressive capacities. Here we review what is currently known about Treg derived exosomes and their contribution to immune regulation, as well as highlighting their possible therapeutic potential for preventing graft rejection, and their possible use as diagnostic tools to assess transplant outcome.

  17. Tune-Based Halo Diagnostics

    International Nuclear Information System (INIS)

    Cameron, Peter

    2003-01-01

    Tune-based halo diagnostics can be divided into two categories -- diagnostics for halo prevention, and diagnostics for halo measurement. Diagnostics for halo prevention are standard fare in accumulators, synchrotrons, and storage rings, and again can be divided into two categories -- diagnostics to measure the tune distribution (primarily to avoid resonances), and diagnostics to identify instabilities (which will not be discussed here). These diagnostic systems include kicked (coherent) tune measurement, phase-locked loop (PLL) tune measurement, Schottky tune measurement, beam transfer function (BTF) measurements, and measurement of transverse quadrupole mode envelope oscillations. We refer briefly to tune diagnostics used at RHIC and intended for the SNS, and then present experimental results. Tune-based diagnostics for halo measurement (as opposed to prevention) are considerably more difficult. We present one brief example of tune-based halo measurement

  18. Development of Tools for Ensuring the Quality of Labor Potential of Industrial Enterprises

    Directory of Open Access Journals (Sweden)

    Ruslan Skrynkovskyy

    2017-09-01

    Full Text Available The purpose of the article is to deepen theoretical and methodological provisions and to develop tools for ensuring the quality of labor potential of industrial enterprises. It was established that the basis of the development of tools for quality assurance of labor potential (within the framework of the development of industrial enterprises lies the system of goals of managerial diagnostics of an industrial enterprise, which includes such key diagnostic objectives as: 1 diagnostics of the effectiveness of controlling the internal business processes of the enterprise; 2 diagnostics of the effectiveness of the typical organizational structure of enterprise management; 3 diagnostics of the efficiency of standardization of the work of linear and functional managers and specialists at the enterprise; 4 diagnostics of the enterprise in the areas of vocational education, labor activity and motivation, innovation work and social development; 5 diagnostics of management policies in the areas of social responsibility, information security and labor protection; 6 diagnostics of the level of conflict in the team at the enterprise 7 diagnosis of the effectiveness of the use of information technology in the management of the enterprise. It was determined that effective management of the quality of labor potential of the personnel (on the basis of its objective assessment is one of the key conditions that determines the success of industrial enterprises. The prospect of further research in this direction is improving the system of diagnostics and planning of reserves for improving the quality of labor potential of an industrial enterprise in crisis conditions.

  19. Study of an extrapolation chamber in a standard diagnostic radiology beam by Monte Carlo simulation

    International Nuclear Information System (INIS)

    Vedovato, Uly Pita; Silva, Rayre Janaina Vieira; Neves, Lucio Pereira; Santos, William S.; Perini, Ana Paula; Belinato, Walmir

    2016-01-01

    In this work, we studied the influence of the components of an extrapolation ionization chamber in its response. This study was undertaken using the MCNP-5 Monte Carlo code, and the standard diagnostic radiology quality for direct beams (RQR5). Using tally F6 and 2.1 x 10"9 simulated histories, the results showed that the chamber design and material not alter significantly the energy deposited in its sensitive volume. The collecting electrode and support board were the components with more influence on the chamber response. (author)

  20. Risk factors for autism: translating genomic discoveries into diagnostics.

    Science.gov (United States)

    Scherer, Stephen W; Dawson, Geraldine

    2011-07-01

    Autism spectrum disorders (ASDs) are a group of conditions characterized by impairments in communication and reciprocal social interaction, and the presence of restricted and repetitive behaviors. The spectrum of autistic features is variable, with severity of symptoms ranging from mild to severe, sometimes with poor clinical outcomes. Twin and family studies indicate a strong genetic basis for ASD susceptibility. Recent progress in defining rare highly penetrant mutations and copy number variations as ASD risk factors has prompted early uptake of these research findings into clinical diagnostics, with microarrays becoming a 'standard of care' test for any ASD diagnostic work-up. The ever-changing landscape of the generation of genomic data coupled with the vast heterogeneity in cause and expression of ASDs (further influenced by issues of penetrance, variable expressivity, multigenic inheritance and ascertainment) creates complexity that demands careful consideration of how to apply this knowledge. Here, we discuss the scientific, ethical, policy and communication aspects of translating the new discoveries into clinical and diagnostic tools for promoting the well-being of individuals and families with ASDs.

  1. Student Interpretations of Diagnostic Feedback

    Science.gov (United States)

    Doe, Christine

    2015-01-01

    Diagnostic assessment is increasingly being recognized as a potentially beneficial tool for teaching and learning (Jang, 2012). There have been calls in the research literature for students to receive diagnostic feedback and for researchers to investigate how such feedback is used by students. Therefore, this study examined how students…

  2. Schistosoma real-time PCR as diagnostic tool for international travellers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Tannich, Egbert; Polman, Katja; Clerinx, Jan; Van Esbroeck, Marjan

    2012-10-01

    To evaluate the use of a genus-specific PCR that combines high sensitivity with the detection of different Schistosoma species for diagnosis in international travellers and migrants in comparison to standard microscopy. The genus-specific real-time PCR was developed to target the 28S ribosomal RNA gene of the major human Schistosoma species. It was validated for analytical specificity and reproducibility and demonstrated an analytical sensitivity of 0.2 eggs per gram of faeces. Its diagnostic performance was further evaluated on 152 faecal, 32 urine and 38 serum samples from patients presenting at the outpatient clinic of the Institute of Tropical Medicine in Antwerp (Belgium). We detected Schistosoma DNA in 76 faecal (50.0%) and five urine (15.6%) samples of which, respectively, nine and one were not detected by standard microscopy. Only two of the 38 serum samples of patients with confirmed schistosomiasis were positive with the presently developed PCR. Sequence analysis on positive faecal samples allowed identification of the Schistosoma species complex. The real-time PCR is highly sensitive and may offer added value in diagnosing imported schistosomiasis. The genus-specific PCR can detect all schistosome species that are infectious to humans and performs very well with faeces and urine, but not in serum. © 2012 Blackwell Publishing Ltd.

  3. Guidelines and algorithms: strategies for standardization of referral criteria in diagnostic radiology

    International Nuclear Information System (INIS)

    Kainberger, Franz; Pokieser, Peter; Imhof, Herwig; Czembirek, Heinrich; Fruehwald, Franz

    2002-01-01

    Guidelines can be regarded as special forms of algorithms and have been shown to be useful tools for supporting medical decision making. With the Council Directive 97/43/Euratom recommendations concerning referral criteria for medical exposure have to be implemented into national law of all EU member states. The time- and cost-consuming efforts of developing, implementing, and updating such guidelines are balanced by the acceptance in clinical practice and eventual better health outcomes. Clearly defined objectives with special attention drawn on national and regional differences among potential users, support from organisations with expertise in evidence-based medicine, separated development of the evidence component and the recommendations component, and large-scale strategies for distribution and implementation are necessary. Editors as well as users of guidelines for referral criteria have to be aware which expectations can be met and which cannot be fulfilled with this instrument; thus, dealing with guidelines requires a new form of ''diagnostic reasoning'' based on medical ethics. (orig.)

  4. Applications of nanoparticles in cancer detection and diagnostic tool for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Venkatasalam, C.; Nagappan, A.

    2012-01-01

    Cancer nanotechnology is multidisciplinary area of science and technology. In recent days nano particles are used in medical field as diagnostic tools. It is highly precious and accurate measurement tools for detecting many disease. One of the broad application of cancer biology, for detecting molecular imaging, molecular diagnosis of cancer cells. In the present study deals with the nanoparticles are widely used for finding tumor as biomarker imaging for cancer detection and the nanoparticles are have important notice. An ample choice of materials may be used for construct nanoparticles that can cover for increase the capability of delivery or to provide unique structural and electrical properties for imaging. This exclusive properties are worn to several functional nanoparticles have already been demonstrated, including some clinically approved liposome drugs and metallic imaging agents. In early detection of heptocellular carcinoma, the metallic nanoparticles are vital role in the imaging technology. Several functions of nanoparticles that may eventually additional the understanding of producing imaging especially the darkening and enlarging of the images. These nanoparticles may be able to identify malignant cells by means of molecular detection, visualization of their location in the body by providing enhanced contrast in medical imaging technology, Through selective particle targeting and monitoring of identification of multiplied cells in different organs of the body. In the future prospective of medical field, the nanoparticles are having vital role for detecting cancer cells. (author)

  5. The Methodological Aspect of the Diagnostics of Objects in Economics

    Directory of Open Access Journals (Sweden)

    Grynko Pavlo О.

    2017-12-01

    Full Text Available The article on the basis of morphological analysis defines the concept of «diagnostics in economics». The differences of diagnostics in economics, economic diagnostics, and analysis in economics were analyzed. The types, functions, principles of diagnostics in economics in modern conditions have been substantiated. The interrelationship of diagnostics with other functions of management in economics has been concretized. The logic and contents of stages of the diagnostic technology in economics have been clarified. The reliability of diagnostics in economics is determined by analytical tools, which are applicable in its implementation. Recommendations of analytical tools for realization of diagnostics in economics have been substantiated. A structural-logical scheme of diagnostics in economics, firming its scientific base and providing objectivity in practical implementation has been proposed.

  6. Assessing children’s competence to consent in research by a standardized tool: a validity study

    Science.gov (United States)

    2012-01-01

    Background Currently over 50% of drugs prescribed to children have not been evaluated properly for use in their age group. One key reason why children have been excluded from clinical trials is that they are not considered able to exercise meaningful autonomy over the decision to participate. Dutch law states that competence to consent can be presumed present at the age of 12 and above; however, in pediatric practice children’s competence is not that clearly presented and the transition from assent to active consent is gradual. A gold standard for competence assessment in children does not exist. In this article we describe a study protocol on the development of a standardized tool for assessing competence to consent in research in children and adolescents. Methods/design In this study we modified the MacCAT-CR, the best evaluated competence assessment tool for adults, for use in children and adolescents. We will administer the tool prospectively to a cohort of pediatric patients from 6 to18 years during the selection stages of ongoing clinical trials. The outcomes of the MacCAT-CR interviews will be compared to a reference standard, established by the judgments of clinical investigators, and an expert panel consisting of child psychiatrists, child psychologists and medical ethicists. The reliability, criterion-related validity and reproducibility of the tool will be determined. As MacCAT-CR is a multi-item scale consisting of 13 items, power was justified at 130–190 subjects, providing a minimum of 10–15 observations per item. MacCAT-CR outcomes will be correlated with age, life experience, IQ, ethnicity, socio-economic status and competence judgment of the parent(s). It is anticipated that 160 participants will be recruited over 2 years to complete enrollment. Discussion A validity study on an assessment tool of competence to consent is strongly needed in research practice, particularly in the child and adolescent population. In this study we will establish

  7. Assessing children’s competence to consent in research by a standardized tool: a validity study

    Directory of Open Access Journals (Sweden)

    Hein Irma M

    2012-09-01

    Full Text Available Abstract Background Currently over 50% of drugs prescribed to children have not been evaluated properly for use in their age group. One key reason why children have been excluded from clinical trials is that they are not considered able to exercise meaningful autonomy over the decision to participate. Dutch law states that competence to consent can be presumed present at the age of 12 and above; however, in pediatric practice children’s competence is not that clearly presented and the transition from assent to active consent is gradual. A gold standard for competence assessment in children does not exist. In this article we describe a study protocol on the development of a standardized tool for assessing competence to consent in research in children and adolescents. Methods/design In this study we modified the MacCAT-CR, the best evaluated competence assessment tool for adults, for use in children and adolescents. We will administer the tool prospectively to a cohort of pediatric patients from 6 to18 years during the selection stages of ongoing clinical trials. The outcomes of the MacCAT-CR interviews will be compared to a reference standard, established by the judgments of clinical investigators, and an expert panel consisting of child psychiatrists, child psychologists and medical ethicists. The reliability, criterion-related validity and reproducibility of the tool will be determined. As MacCAT-CR is a multi-item scale consisting of 13 items, power was justified at 130–190 subjects, providing a minimum of 10–15 observations per item. MacCAT-CR outcomes will be correlated with age, life experience, IQ, ethnicity, socio-economic status and competence judgment of the parent(s. It is anticipated that 160 participants will be recruited over 2 years to complete enrollment. Discussion A validity study on an assessment tool of competence to consent is strongly needed in research practice, particularly in the child and adolescent population. In

  8. Tool for evaluation compliance standards and expectations in occupational risk prevention by collaborating companies

    International Nuclear Information System (INIS)

    Duran Perez, A.; Gomez Pardo, M. A.; Cao Tejero, R.; Millan Verdejo, J. A.; Blas Perez, P.

    2013-01-01

    Within the framework of a single security in ANAV, in our Action Plan on prevention, we consider it essential to include workers from ECCE working for and by ANAV in compliance with standards and expectations both in the accounts of the incidents. With this system is intended to standardize a set of observed deviations report and a tool for measuring the degree of compliance, allowing to monitor the evolution of each company and the effectiveness of prevention plan.

  9. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    Science.gov (United States)

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory

  10. Trace element analysis: a diagnostic tool

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Cheema, M.N.

    1976-09-01

    The human mody continuously assimilates a variety of elements from the environment, and the concentration of these elements in the blood is regulated by means of various homeostatic mechanisms. Some of the elements, though present in very small amounts, have highly specialized functions in initiating many biochemical reactions. These elements, known as essential trace elements, are closely related to human diseases since their deficiency or excess induces physiological changes. Many diseases such as hypertension, atherosclerosis, diabetes, etc., are related to an imbalance in trace element. The measurement of trace elements in body fluids and tissues can, therefore, be effectively employed for diagnostic tests

  11. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a prospective study.

    Science.gov (United States)

    da Costa, Bruno R; Beckett, Brooke; Diaz, Alison; Resta, Nina M; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2017-03-03

    The Cochrane risk of bias tool is commonly criticized for having a low reliability. We aimed to investigate whether training of raters, with objective and standardized instructions on how to assess risk of bias, can improve the reliability of the Cochrane risk of bias tool. In this pilot study, four raters inexperienced in risk of bias assessment were randomly allocated to minimal or intensive standardized training for risk of bias assessment of randomized trials of physical therapy treatments for patients with knee osteoarthritis pain. Two raters were experienced risk of bias assessors who served as reference. The primary outcome of our study was between-group reliability, defined as the agreement of the risk of bias assessments of inexperienced raters with the reference assessments of experienced raters. Consensus-based assessments were used for this purpose. The secondary outcome was within-group reliability, defined as the agreement of assessments within pairs of inexperienced raters. We calculated the chance-corrected weighted Kappa to quantify agreement within and between groups of raters for each of the domains of the risk of bias tool. A total of 56 trials were included in our analysis. The Kappa for the agreement of inexperienced raters with reference across items of the risk of bias tool ranged from 0.10 to 0.81 for the minimal training group and from 0.41 to 0.90 for the standardized training group. The Kappa values for the agreement within pairs of inexperienced raters across the items of the risk of bias tool ranged from 0 to 0.38 for the minimal training group and from 0.93 to 1 for the standardized training group. Between-group differences in Kappa for the agreement of inexperienced raters with reference always favored the standardized training group and was most pronounced for incomplete outcome data (difference in Kappa 0.52, p training on risk of bias assessment may significantly improve the reliability of the Cochrane risk of bias tool.

  12. Diagnostic utility of selective nerve root blocks in the diagnosis of lumbosacral radicular pain: systematic review and update of current evidence.

    Science.gov (United States)

    Datta, Sukdeb; Manchikanti, Laxmaiah; Falco, Frank J E; Calodney, Aaron K; Atluri, Sairam; Benyamin, Ramsin M; Buenaventura, Ricardo M; Cohen, Steven P

    2013-04-01

      Lumbosacral selective nerve root blocks and/ or transforaminal epidural injections are used for diagnosis and treatment of different disorders causing low back and lower extremity pain. A clear consensus on the use of selective nerve root injections as a diagnostic tool does not currently exist. Additionally, the validity of this procedure as a diagnostic tool is not clear. To evaluate and update the accuracy of selective nerve root injections in diagnosing lumbar spinal disorders. A systematic review of selective nerve root blocks for the diagnosis of low back and lower extremity pain. Methodological quality assessment of included studies was performed using the Quality Appraisal of Reliability Studies (QAREL) checklist. Only diagnostic accuracy studies meeting at least 50% of the designated inclusion criteria were utilized for analysis. Studies scoring less than 50% are presented descriptively and analyzed critically. The level of evidence was classified as good, fair, or limited or poor based on the quality of evidence grading scale developed by the United States Preventive Services Task Force (USPSTF). Data sources included relevant literature identified through searches of PubMed and EMBASE from 1966 to September 2012, and manual searches of the bibliographies of known primary and review articles. In this review, we evaluated studies in which controlled local anesthetic blocks were performed using at least 50% pain relief as the reference standard. There is limited evidence for the accuracy of selective nerve root injections as a diagnostic tool for lumbosacral disorders. There is limited evidence for their use in the preoperative evaluation of patients with negative or inconclusive imaging studies. The limitations of this systematic review include a paucity of literature, variations in technique, and variable criterion standards for the diagnosis of lumbar radicular pain. There is limited evidence for selective nerve root injections as a diagnostic tool in

  13. Standardized Ki67 Diagnostics Using Automated Scoring--Clinical Validation in the GeparTrio Breast Cancer Study.

    Science.gov (United States)

    Klauschen, Frederick; Wienert, Stephan; Schmitt, Wolfgang D; Loibl, Sibylle; Gerber, Bernd; Blohmer, Jens-Uwe; Huober, Jens; Rüdiger, Thomas; Erbstößer, Erhard; Mehta, Keyur; Lederer, Bianca; Dietel, Manfred; Denkert, Carsten; von Minckwitz, Gunter

    2015-08-15

    Scoring proliferation through Ki67 immunohistochemistry is an important component in predicting therapy response to chemotherapy in patients with breast cancer. However, recent studies have cast doubt on the reliability of "visual" Ki67 scoring in the multicenter setting, particularly in the lower, yet clinically important, proliferation range. Therefore, an accurate and standardized Ki67 scoring is pivotal both in routine diagnostics and larger multicenter studies. We validated a novel fully automated Ki67 scoring approach that relies on only minimal a priori knowledge on cell properties and requires no training data for calibration. We applied our approach to 1,082 breast cancer samples from the neoadjuvant GeparTrio trial and compared the performance of automated and manual Ki67 scoring. The three groups of autoKi67 as defined by low (≤ 15%), medium (15.1%-35%), and high (>35%) automated scores showed pCR rates of 5.8%, 16.9%, and 29.5%, respectively. AutoKi67 was significantly linked to prognosis with overall and progression-free survival P values P(OS) cancer that correlated with clinical endpoints and is deployable in routine diagnostics. It may thus help to solve recently reported reliability concerns in Ki67 diagnostics. ©2014 American Association for Cancer Research.

  14. Cross-cultural validity of standardized motor development screening and assessment tools: a systematic review.

    Science.gov (United States)

    Mendonça, Bianca; Sargent, Barbara; Fetters, Linda

    2016-12-01

    To investigate whether standardized motor development screening and assessment tools that are used to evaluate motor abilities of children aged 0 to 2 years are valid in cultures other than those in which the normative sample was established. This was a systematic review in which six databases were searched. Studies were selected based on inclusion/exclusion criteria and appraised for evidence level and quality. Study variables were extracted. Twenty-three studies representing six motor development screening and assessment tools in 16 cultural contexts met the inclusion criteria: Alberta Infant Motor Scale (n=7), Ages and Stages Questionnaire, 3rd edition (n=2), Bayley Scales of Infant and Toddler Development, 3rd edition (n=8), Denver Developmental Screening Test, 2nd edition (n=4), Harris Infant Neuromotor Test (n=1), and Peabody Developmental Motor Scales, 2nd edition (n=1). Thirteen studies found significant differences between the cultural context and normative sample. Two studies established reliability and/or validity of standardized motor development assessments in high-risk infants from different cultural contexts. Five studies established new population norms. Eight studies described the cross-cultural adaptation of a standardized motor development assessment. Standardized motor development assessments have limited validity in cultures other than that in which the normative sample was established. Their use can result in under- or over-referral for services. © 2016 Mac Keith Press.

  15. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  16. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    International Nuclear Information System (INIS)

    Sundstroem, Torbjoern; Riklund, Katrine Aa.; Elgh, Eva; Naesman, Birgitta; Larsson, Anne; Nyberg, Lars

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2±4.8 years) with mild AD and 18 healthy elderly (69.4±3.9 years) were included in the study. The subjects were injected with 99m Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF 99m Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  17. Intelligent model-based diagnostics for vehicle health management

    Science.gov (United States)

    Luo, Jianhui; Tu, Fang; Azam, Mohammad S.; Pattipati, Krishna R.; Willett, Peter K.; Qiao, Liu; Kawamoto, Masayuki

    2003-08-01

    The recent advances in sensor technology, remote communication and computational capabilities, and standardized hardware/software interfaces are creating a dramatic shift in the way the health of vehicles is monitored and managed. These advances facilitate remote monitoring, diagnosis and condition-based maintenance of automotive systems. With the increased sophistication of electronic control systems in vehicles, there is a concomitant increased difficulty in the identification of the malfunction phenomena. Consequently, the current rule-based diagnostic systems are difficult to develop, validate and maintain. New intelligent model-based diagnostic methodologies that exploit the advances in sensor, telecommunications, computing and software technologies are needed. In this paper, we will investigate hybrid model-based techniques that seamlessly employ quantitative (analytical) models and graph-based dependency models for intelligent diagnosis. Automotive engineers have found quantitative simulation (e.g. MATLAB/SIMULINK) to be a vital tool in the development of advanced control systems. The hybrid method exploits this capability to improve the diagnostic system's accuracy and consistency, utilizes existing validated knowledge on rule-based methods, enables remote diagnosis, and responds to the challenges of increased system complexity. The solution is generic and has the potential for application in a wide range of systems.

  18. Application of the denaturing gradient gel electrophoresis (DGGE) technique as an efficient diagnostic tool for ciliate communities in soil.

    Science.gov (United States)

    Jousset, Alexandre; Lara, Enrique; Nikolausz, Marcell; Harms, Hauke; Chatzinotas, Antonis

    2010-02-01

    Ciliates (or Ciliophora) are ubiquitous organisms which can be widely used as bioindicators in ecosystems exposed to anthropogenic and industrial influences. The evaluation of the environmental impact on soil ciliate communities with methods relying on morphology-based identification may be hampered by the large number of samples usually required for a statistically supported, reliable conclusion. Cultivation-independent molecular-biological diagnostic tools are a promising alternative to greatly simplify and accelerate such studies. In this present work a ciliate-specific fingerprint method based on the amplification of a phylogenetic marker gene (i.e. the 18S ribosomal RNA gene) with subsequent analysis by denaturing gradient gel electrophoresis (DGGE) was developed and used to monitor community shifts in a polycyclic aromatic hydrocarbon (PAH) polluted soil. The semi-nested approach generated ciliate-specific amplification products from all soil samples and allowed to distinguish community profiles from a PAH-polluted and a non-polluted control soil. Subsequent sequence analysis of excised bands provided evidence that polluted soil samples are dominated by organisms belonging to the class Colpodea. The general DGGE approach presented in this study might thus in principle serve as a fast and reproducible diagnostic tool, complementing and facilitating future ecological and ecotoxicological monitoring of ciliates in polluted habitats. Copyright 2009 Elsevier B.V. All rights reserved.

  19. Highly polymorphic RFLP probes as diagnostic tools

    International Nuclear Information System (INIS)

    Donis-Keller, H.; Barker, D.F.; Knowlton, R.G.; Schumm, J.W.; Braman, J.C.; Green, P.

    1986-01-01

    In this paper, we describe the identification of highly polymorphic RFLP loci and their application to genotyping in humans and to mapping the CF gene to chromosome 7. We also report the construction of a high-resolution genetic map of chromosome 7 and summarize progress toward the development of a presymptomatic diagnostic test for CF that should be useful in virtually every case. 25 references, 7 figures, 5 tables

  20. Methodological issues in systematic reviews of headache trials: adapting historical diagnostic classifications and outcome measures to present-day standards.

    Science.gov (United States)

    McCrory, Douglas C; Gray, Rebecca N; Tfelt-Hansen, Peer; Steiner, Timothy J; Taylor, Frederick R

    2005-05-01

    Recent efforts to make headache diagnostic classification and clinical trial methodology more consistent provide valuable advice to trialists generating new evidence on effectiveness of treatments for headache; however, interpreting older trials that do not conform to new standards remains problematic. Systematic reviewers seeking to utilize historical data can adapt currently recommended diagnostic classification and clinical trial methodological approaches to interpret all available data relative to current standards. In evaluating study populations, systematic reviewers can: (i) use available data to attempt to map study populations to diagnoses in the new International Classification of Headache Disorders; and (ii) stratify analyses based on the extent to which study populations are precisely specified. In evaluating outcome measures, systematic reviewers can: (i) summarize prevention studies using headache frequency, incorporating headache index in a stratified analysis if headache frequency is not available; (ii) summarize acute treatment studies using pain-free response as reported in directly measured headache improvement or headache severity outcomes; and (iii) avoid analysis of recurrence or relapse data not conforming to the sustained pain-free response definition.

  1. No gold standard estimation of the sensitivity and specificity of two molecular diagnostic protocols for Trypanosoma brucei spp. in Western Kenya.

    Directory of Open Access Journals (Sweden)

    Barend Mark de Clare Bronsvoort

    2010-01-01

    Full Text Available African animal trypanosomiasis is caused by a range of tsetse transmitted protozoan parasites includingTrypanosoma vivax, Trypanosoma congolense and Trypansoma brucei. In Western Kenya and other parts of East Africa two subspecies of T. brucei, T.b. brucei and the zoonoticT.b. rhodesiense, co-circulate in livestock. A range of polymerase chain reactions (PCR have been developed as important molecular diagnostic tools for epidemiological investigations of T. brucei s.l. in the animal reservoir and of its zoonotic potential. Quantification of the relative performance of different diagnostic PCRs is essential to ensure comparability of studies. This paper describes an evaluation of two diagnostic test systems for T. brucei using a T. brucei s.l. specific PCR [1] and a single nested PCR targeting the Internal Transcribed Spacer (ITS regions of trypanosome ribosomal DNA [2]. A Bayesian formulation of the Hui-Walter latent class model was employed to estimate their test performance in the absence of a gold standard test for detecting T.brucei s.l. infections in ear-vein blood samples from cattle, pig, sheep and goat populations in Western Kenya, stored on Whatman FTA cards. The results indicate that the system employing the T. brucei s.l. specific PCR (Se1=0.760 had a higher sensitivity than the ITS-PCR (Se2=0.640; both have high specificity (Sp1=0.998; Sp2=0.997. The true prevalences for livestock populations were estimated (pcattle=0.091, ppigs=0.066, pgoats=0.005, psheep=0.006, taking into account the uncertainties in the specificity and sensitivity of the two test systems. Implications of test performance include the required survey sample size; due to its higher sensitivity and specificity, the T. brucei s.l. specific PCR requires a consistently smaller sample size than the ITS-PCR for the detection of T. brucei s.l. However the ITS-PCR is able to simultaneously screen samples for other pathogenic trypanosomes and may thus be, overall, a better

  2. A Simple Evaluation Tool (ET-CET) Indicates Increase of Diagnostic Skills From Small Bowel Capsule Endoscopy Training Courses

    OpenAIRE

    Albert, J.G.; Humbla, O.; McAlindon, M.E.; Davison, C.; Seitz, U.; Fraser, C.; Hagenm?ller, F.; Noetzel, E.; Spada, C.; Riccioni, M.E.; Barnert, J.; Filmann, N.; Keuchel, M.

    2015-01-01

    Abstract Small bowel capsule endoscopy (SBCE) has become a first line diagnostic tool. Several training courses with a similar format have been established in Europe; however, data on learning curve and training in SBCE remain sparse. Between 2008 and 2011, different basic SBCE training courses were organized internationally in UK (n?=?2), Italy (n?=?2), Germany (n?=?2), Finland (n?=?1), and nationally in Germany (n?=?10), applying similar 8-hour curricula with 50% lectures and 50% hands-on t...

  3. In-vitro diagnostic devices introduction to current point-of-care diagnostic devices

    CERN Document Server

    Cheng, Chao-Min; Chen, Chien-Fu

    2016-01-01

    Addressing the origin, current status, and future development of point-of-care diagnostics, and serving to integrate knowledge and tools from Analytical Chemistry, Bioengineering, Biomaterials, and Nanotechnology, this book focusses on addressing the collective and combined needs of industry and academia (including medical schools) to effectively conduct interdisciplinary research. In addition to summarizing and detailing developed diagnostic devices, this book will attempt to point out the possible future trends of development for point-of-care diagnostics using both scientifically based research and practical engineering needs with the aim to help novices comprehensively understand the development of point-of-care diagnostics. This includes demonstrating several common but critical principles and mechanisms used in point-of-care diagnostics that address practical needs (e.g., disease or healthcare monitoring) using two well-developed examples so far: 1) blood glucose meters (via electrochemistry); and, 2) p...

  4. Diagnostic tests for Helicobacter pylori : A prospective evaluation of their accuracy, without selecting a single test as the gold standard

    NARCIS (Netherlands)

    Thijs, J C; van Zwet, A A; Thijs, W J; Oey, H B; Karrenbeld, A; Stellaard, F; Luijt, D S; Meyer, B C; Kleibeuker, J H

    1996-01-01

    OBJECTIVE: To assess the accuracy of six commonly used diagnostic tests for Helicobacter pylori in a prospective study without using any specific test as the gold standard (the patient was regarded as H. pylori-infected if two or more tests, whatever their nature, were positive). METHODS: In 105

  5. Exploratory Study of the Diagnostic Abilities of the Baptista Depression Scale Adult Version (EBADEP-A

    Directory of Open Access Journals (Sweden)

    Makilim Nunes Baptista

    2013-09-01

    Full Text Available This study’s objective was to analyze the diagnostic capabilities of a depression screening scale. For that, this scale was administered along with two diagnostic instruments, namely, the structured clinical interview from the DSM-IV (SCID-CV and the Hamilton Depression Scale (HAM-D, which are considered to be the gold standard for diagnosing depressive disorders. Participants were 22 subjects diagnosed by psychiatrists with Major Depressive Disorder. The EBADEP-A correctly identified cases of depression, showing a high correlation with the HAM-D, which indicates the scale correctly captures most depressive symptoms, even though it was initially used as a depression-screening tool.

  6. Standardizing the experimental conditions for using urine in NMR-based metabolomic studies with a particular focus on diagnostic studies: a review

    KAUST Repository

    Emwas, Abdul-Hamid M.

    2014-11-21

    The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.

  7. Standardizing the experimental conditions for using urine in NMR-based metabolomic studies with a particular focus on diagnostic studies: a review

    KAUST Repository

    Emwas, Abdul-Hamid M.; Luchinat, Claudio; Turano, Paola; Tenori, Leonardo; Roy, Raja; Salek, Reza M.; Ryan, Danielle; Merzaban, Jasmeen; Kaddurah-Daouk, Rima; Zeri, Ana Carolina; Nagana Gowda, G. A.; Raftery, Daniel; Wang, Yulan; Brennan, Lorraine; Wishart, David S.

    2014-01-01

    The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.

  8. Standardizing the experimental conditions for using urine in NMR-based metabolomic studies with a particular focus on diagnostic studies: a review.

    Science.gov (United States)

    Emwas, Abdul-Hamid; Luchinat, Claudio; Turano, Paola; Tenori, Leonardo; Roy, Raja; Salek, Reza M; Ryan, Danielle; Merzaban, Jasmeen S; Kaddurah-Daouk, Rima; Zeri, Ana Carolina; Nagana Gowda, G A; Raftery, Daniel; Wang, Yulan; Brennan, Lorraine; Wishart, David S

    The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.

  9. Microbial Diagnostic Array Workstation (MDAW: a web server for diagnostic array data storage, sharing and analysis

    Directory of Open Access Journals (Sweden)

    Chang Yung-Fu

    2008-09-01

    Full Text Available Abstract Background Microarrays are becoming a very popular tool for microbial detection and diagnostics. Although these diagnostic arrays are much simpler when compared to the traditional transcriptome arrays, due to the high throughput nature of the arrays, the data analysis requirements still form a bottle neck for the widespread use of these diagnostic arrays. Hence we developed a new online data sharing and analysis environment customised for diagnostic arrays. Methods Microbial Diagnostic Array Workstation (MDAW is a database driven application designed in MS Access and front end designed in ASP.NET. Conclusion MDAW is a new resource that is customised for the data analysis requirements for microbial diagnostic arrays.

  10. Circulating nucleic acids as a new diagnostic tool

    Czech Academy of Sciences Publication Activity Database

    Urbanová, Markéta; Plzák, J.; Strnad, Hynek; Betka, J.

    2010-01-01

    Roč. 15, č. 2 (2010), s. 242-259 ISSN 1425-8153 R&D Projects: GA MŠk 2B06106 Institutional research plan: CEZ:AV0Z50520514 Keywords : circulating nucleic acids * diagnostics * cancer Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.455, year: 2010

  11. Development, validation and psychometric properties of a diagnostic/prognostic tool for breakthrough pain in mixed chronic-pain patients.

    Science.gov (United States)

    Samolsky Dekel, Boaz Gedaliahu; Remondini, Francesca; Gori, Alberto; Vasarri, Alessio; Di Nino, GianFranco; Melotti, Rita Maria

    2016-02-01

    Breakthrough pain (BTP) shows variable prevalence in different clinical contexts of cancer and non-cancer patients. BTP diagnostic tools with demonstrated reliability, validation and prognostic capability are lacking. We report the development, psychometric and validation properties of a diagnostic/prognostic tool, the IQ-BTP, for BTP recognition, its likelihood and clinical features among chronic-pain (CP) patients. n=120 consecutive mixed cancer/non-cancer CP in/outpatients. Development, psychometric analyses and formal validation included: Face/Content validity (by 'experts' opinion and assessing the relationship between the IQ-BTP classes and criteria derived from BTP operational-case-definition); Construct validity, by Principle Component Analysis (PCA); and the strength of Spearman correlation between IQ-BTP classes and the Brief Pain Inventory (BPI) items; Reliability, by Cronbach's alpha statistics. Associations with clinical/demographic moderators were assessed applying χ(2) analysis. Potential-BTP was found in 36.7% of patients (38.4% of non-cancer and 32.4% of cancer patients). Among these the likelihood for BTP diagnosis was 'high' in 25%, 'intermediate' in 41% and, 'low' 34% of patients. Analyses showed significant differences between IQ-BTP classes and between the latter BPI pain-item scores. Correlation between IQ-BTP classes and BPI items was moderate. PCA and scree test identified 3 components accounting for 62.3% of the variance. Cronbach's alpha was 0.71. The IQ-BTP showed satisfactory psychometric and validation properties. With adequate feasibility it enabled the allocating of cancer/non-cancer CP patients in three prognostic classes. Results are sufficient to warrant a subsequent impact study of the IQ-BTP as prognostic model and screening tool for BTP in both CP populations. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Comparison of clinical and paraclinical parameters as tools for early diagnosis of classical swine fever

    DEFF Research Database (Denmark)

    Lohse, Louise; Uttenthal, Åse; Nielsen, Jens

    Comparison of clinical and paraclinical parameters as tools for early diagnosis of classical swine fever. Louise Lohse, Åse Uttenthal, Jens Nielsen. National Veterinary Institute, Division of Virology, Lindholm, Technical University of Denmark. Introduction: In order to limit the far-reaching socio......-economic as well as the animal welfare consequences of an outbreak of classical swine fever (CSF), early diagnosis is essential. However, host-virus interactions strongly influence the course of CSF disease, and the clinical feature is not clear, thus complicating the diagnostic perspective. At the National...... Veterinary Institute, in Denmark, we are conducting a series of animal experiments under standardized conditions in order to investigate new parameters of clinical as well as paraclinical nature that holds the potential as diagnostic tools to improve early detection of CSF. In three recent studies, weaned...

  13. T-scan III system diagnostic tool for digital occlusal analysis in orthodontics - a modern approach.

    Science.gov (United States)

    Trpevska, Vesna; Kovacevska, Gordana; Benedeti, Alberto; Jordanov, Bozidar

    2014-01-01

    This systematic literature review was performed to establish the mechanism, methodology, characteristics, clinical application and opportunities of the T-Scan III System as a diagnostic tool for digital occlusal analysis in different fields of dentistry, precisely in orthodontics. Searching of electronic databases, using MEDLINE and PubMed, hand searching of relevant key journals, and screening of reference lists of included studies with no language restriction was performed. Publications providing statistically examined data were included for systematic review. Twenty potentially relevant Randomized Controlled Trials (RCTs) were identified. Only ten met the inclusion criteria. The literature demonstrates that using digital occlusal analysis with T-Scan III System in orthodontics has significant advantage with regard to the capability of measuring occlusal parameters in static positions and during dynamic of the mandible. Within the scope of this systematic review, there is evidence to support that T-Scan system is rapid and accurate in identifying the distribution of the tooth contacts and it shows great promise as a clinical diagnostic screening device for occlusion and for improving the occlusion after various dental treatments. Additional clinical studies are required to advance the indication filed of this system. Importance of using digital occlusal T-Scan analysis in orthodontics deserves further investigation.

  14. Monitoring the Diagnostic Process on an Inpatient Neurology Service.

    Science.gov (United States)

    Dhand, Amar; Bucelli, Robert; Varadhachary, Arun; Tsiaklides, Michael; de Bruin, Gabriela; Dhaliwal, Gurpreet

    2017-07-01

    The Institute of Medicine report Improving Diagnosis in Health Care called for tools to monitor physicians' diagnostic process. We addressed this need by developing a tool for clinicians to record and analyze their diagnostic process. The tool was a secure web application in which clinicians used a structured grading system to assess the relative impact of clinical, laboratory, and neuroimaging data for every new diagnosis. Four neurohospitalists used the tool for 6.5 months on a general neurology ward service at a single tertiary-level teaching hospital. Process measures of tool use included number of diagnoses entered, time spent on each data entry, and concordance of diagnoses compared to the medical record. We also aggregated the data across clinicians to examine the average process scores across common inpatient disorders. The 4 clinicians entered 254 new diagnoses that took approximately 3 minutes per patient. In 50 randomly chosen cases, the neurohospitalists' diagnoses entered into the tool agreed with 92% of diagnoses in the medical record, which was better than the agreement between billing code and medical record diagnoses (74%). The diagnostic process varied across disease categories, showing a spectrum of clinical-dominant (eg, headache), laboratory-dominant (eg, encephalitis), and neuroimaging-dominant (eg, stroke) disorders. This study demonstrated the feasibility of a clinician-driven diagnostic process monitoring system, along with preliminary characterization of the process for common disorders. The tracking of diagnostic process has the potential to promote reflection on clinical practice, deconstruct neurologists' clinical decision-making, and improve health-care safety.

  15. Russian Language Development Assessment as a Standardized Technique for Assessing Communicative Function in Children Aged 3–9 Years

    Directory of Open Access Journals (Sweden)

    Prikhoda N.A.,

    2016-10-01

    Full Text Available The article describes the Russian Language Development Assessment, a standardized individual diagnostic tool for children aged from 3 to 9 that helps to assess the following components of a child’s communicative function: passive vocabulary, expressive vocabulary, knowledge of semantic constructs with logical, temporal and spatial relations, passive perception and active use of syntactic and morphological features of words in a sentence, active and passive phonological awareness, active and passive knowledge of syntactic structures and categories. The article provides descriptions of content and diagnostic procedures for all 7 subtests included in the assessment (Passive Vocabulary, Active Vocabulary, Linguistic Operators, Sentence structure, Word Structure, Phonology, Sentence Repetition. Basing on the data collected in the study that involved 86 first- graders of a Moscow school, the article analyzes the internal consistency and construct validity of each subtest of the technique. It concludes that the Russian Language Development Assessment technique can be of much use both in terms of diagnostic purposes and in supporting children with ASD taking into account the lack of standardized tools for language and speech development assessment in Russian and the importance of this measure in general.

  16. Diagnostic Performance of F-18 FDG PET/CT in Patients with Cancer of Unknown Primary: Additional Benefit over CT-Based Conventional Work up

    Directory of Open Access Journals (Sweden)

    Mehrdad Bakhshayeshkaram

    2016-01-01

    Full Text Available Background: In the era of well-developed site-specific treatment strategies in cancer, identification of occult primary is of paramount importance in CUP patients. Furthermore, exact determination of the extent of the disease may help in optimizing treatment planning. The aim of the present study was to investigate additional value of F-18 FDG PET/CT in patients with cancer of unknown primary (CUP as an appropriate imaging tool in early phase of initial standard work up.Materials and Methods: Sixty-two newly diagnosed CUP patients with inconclusive diagnostic CT scan of chest, abdomen and pelvis referring for F-18 FDG PET/CT were enrolled in this study. Standard of reference was defined as histopathology, other diagnostic procedures and a 3-month formal clinical follow up. The results of PET/CT were categorized as suggestion for primary site and additional metastasis and classified as true positive, false positive, false negative and true negative. The impact of additional metastasis revealed by F-18 FDG PET/CT on treatment planning and the time contribution of F-18 FDG PET/CT in diagnostic pathway was investigated.Results: Sixty-two patients with mean age of 62 (30 men, 32 women, PET/CT correctly identified primary origin in 32% with false positive rate of 14.8%. No primary lesion was detected after negative PET/CT according to standard of reference. Sensitivity, Specificity and accuracy were 100%, 78% and 85%, respectively. Additional metastatic site was found in 56% with 22% impact on treatment planning. Time contribution for PET/CT was 10% of total diagnostic pathway.Conclusion: Providing higher detection rate of primary origin with excellent diagnostic performance, shortening the diagnostic pathway and improving treatment planning, F-18 FDG PET/CT may play a major role in diagnostic work up of CUP patients and may be recommended as an alternative imaging tool in early phase of investigation.

  17. Vulnerability analysis of DT fusion diagnostics for laser Megajoule facility. A new tool: Diacad; Analyse de vulnerabilite de chaines de diagnostic pour la fusion DT dans le cadre du laser megajoule. Un nouvel outil: diacad

    Energy Technology Data Exchange (ETDEWEB)

    D' hose, C.; Baggio, J.; Musseau, O. [CEA Bruyeres-le-Chatel, 91 (France)

    1999-07-01

    The Megajoule laser (LMJ) project is a major component of the French simulation program to study inertial confinement. This new facility will provide an energy 60 times greater than the largest lasers presently available (Phebus, Nova, Omega). Many diagnostic links will have to be developed in order to acquire complementary knowledge in this domain. A computer based tool has been defined. This paper presents the most recent developments of this new CAD (computer assisted diagnosis) tool. We first describe LMJ context, and then the analysis methodology developed to address the sensitivity to transient radiation of nuclear diagnosis links. This tool takes into account the vulnerability of individual parts and the global structure of the link. (A.C.)

  18. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a study protocol.

    Science.gov (United States)

    da Costa, Bruno R; Resta, Nina M; Beckett, Brooke; Israel-Stahre, Nicholas; Diaz, Alison; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2014-12-13

    The Cochrane risk of bias (RoB) tool has been widely embraced by the systematic review community, but several studies have reported that its reliability is low. We aim to investigate whether training of raters, including objective and standardized instructions on how to assess risk of bias, can improve the reliability of this tool. We describe the methods that will be used in this investigation and present an intensive standardized training package for risk of bias assessment that could be used by contributors to the Cochrane Collaboration and other reviewers. This is a pilot study. We will first perform a systematic literature review to identify randomized clinical trials (RCTs) that will be used for risk of bias assessment. Using the identified RCTs, we will then do a randomized experiment, where raters will be allocated to two different training schemes: minimal training and intensive standardized training. We will calculate the chance-corrected weighted Kappa with 95% confidence intervals to quantify within- and between-group Kappa agreement for each of the domains of the risk of bias tool. To calculate between-group Kappa agreement, we will use risk of bias assessments from pairs of raters after resolution of disagreements. Between-group Kappa agreement will quantify the agreement between the risk of bias assessment of raters in the training groups and the risk of bias assessment of experienced raters. To compare agreement of raters under different training conditions, we will calculate differences between Kappa values with 95% confidence intervals. This study will investigate whether the reliability of the risk of bias tool can be improved by training raters using standardized instructions for risk of bias assessment. One group of inexperienced raters will receive intensive training on risk of bias assessment and the other will receive minimal training. By including a control group with minimal training, we will attempt to mimic what many review authors

  19. Genetic Mimetics of Mycobacterium tuberculosis and Methicillin-Resistant Staphylococcus aureus as Verification Standards for Molecular Diagnostics.

    Science.gov (United States)

    Machowski, Edith Erika; Kana, Bavesh Davandra

    2017-12-01

    Molecular diagnostics have revolutionized the management of health care through enhanced detection of disease or infection and effective enrollment into treatment. In recognition of this, the World Health Organization approved the rollout of nucleic acid amplification technologies for identification of Mycobacterium tuberculosis using platforms such as GeneXpert MTB/RIF, the GenoType MTBDR plus line probe assay, and, more recently, GeneXpert MTB/RIF Ultra. These assays can simultaneously detect tuberculosis infection and assess rifampin resistance. However, their widespread use in health systems requires verification and quality assurance programs. To enable development of these, we report the construction of genetically modified strains of Mycobacterium smegmatis that mimic the profile of Mycobacterium tuberculosis on both the GeneXpert MTB/RIF and the MTBDR plus line probe diagnostic tests. Using site-specific gene editing, we also created derivatives that faithfully mimic the diagnostic result of rifampin-resistant M. tuberculosis , with mutations at positions 513, 516, 526, 531, and 533 in the rifampin resistance-determining region of the rpoB gene. Next, we extended this approach to other diseases and demonstrated that a Staphylococcus aureus gene sequence can be introduced into M. smegmatis to generate a positive response for the SCC mec probe in the GeneXpert SA Nasal Complete molecular diagnostic cartridge, designed for identification of methicillin-resistant S. aureus These biomimetic strains are cost-effective, have low biohazard content, accurately mimic drug resistance, and can be produced with relative ease, thus illustrating their potential for widespread use as verification standards for diagnosis of a variety of diseases. Copyright © 2017 American Society for Microbiology.

  20. Diagnostic accuracy of touch imprint cytology for head and neck malignancies: a useful intra-operative tool in resource limited countries.

    Science.gov (United States)

    Naveed, Hania; Abid, Mariam; Hashmi, Atif Ali; Edhi, Muhammad Muzammamil; Sheikh, Ahmareen Khalid; Mudassir, Ghazala; Khan, Amir

    2017-01-01

    Intraoperative consultation is an important tool for the evaluation of the upper aerodigestive tract (UAT) malignancies. Although frozen section analysis is a preferred method of intra-operative consultation, however in resource limited countries like Pakistan, this facility is not available in most institutes; therefore, we aimed to evaluate the diagnostic accuracy of touch imprint cytology for UAT malignancies using histopathology of the same tissue as gold standard. The study involved 70 cases of UAT lesions operated during the study period. Intraoperatively, after obtaining the fresh biopsy specimen and prior to placing them in fixative, each specimen was imprinted on 4-6 glass slides, fixed immediately in 95% alcohol and stained with Hematoxylin and Eosin stain. After completion of the cytological procedure, the surgical biopsy specimen was processed. The slides of both touch Imprint cytology and histopathology were examined by two consultant histopathologists. The result of touch imprint cytology showed that touch imprint cytology was diagnostic in 68 cases (97.1%), 55 (78.6%) being malignant, 2 cases (2.9%) were suspicious for malignancy, 11 cases (15.7%) were negative for malignancy while 2 cases (2.9%) were false negative. Amongst the 70 cases, 55 cases (78.6%) were malignant showing squamous cell carcinoma in 49 cases (70%), adenoid cystic carcinoma in 2 cases (2.9%), non-Hodgkin lymphoma 2 cases (2.9%), Mucoepidermoid carcinoma 1 case (1.4%), spindle cell sarcoma in 1 case (1.4%). Two cases (2.9%) were suspicious of malignancy showing atypical squamoid cells on touch imprint cytology, while 13 cases (18.6%) were negative for malignancy, which also included 2 false negative cases. The overall diagnostic accuracy of touch imprint cytology came out to be 96.7% with a sensitivity and specificity of 96 and 100%, respectively while PPV and NPV of touch imprint cytology was found to be 100 and 84%, respectively. Our experience in this study has demonstrated

  1. Magnetic diagnostics for the proto-eta Tokamak

    International Nuclear Information System (INIS)

    Ferreira, J.L.; Aso, Y.; Ueda, M.; Ferreira, J.G.

    1991-04-01

    This work gives a general view of the magnetic diagnostics rat will be used in the Proto-Eta Tokamak. These diagnostics will be useful tools to measure currents, electric and magnetic fields involved in the plasma magnetic confinement. (author)

  2. Validation Tools and Methods for Diagnostic Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The potential benefits of advanced algorithms for diagnostics and prognostics, inner-loop control, and other flight critical systems have been demonstrated in a...

  3. Hypersensitivity and desensitization to antineoplastic agents: outcomes of 189 procedures with a new short protocol and novel diagnostic tools assessment.

    Science.gov (United States)

    Madrigal-Burgaleta, R; Berges-Gimeno, M P; Angel-Pereira, D; Ferreiro-Monteagudo, R; Guillen-Ponce, C; Pueyo, C; Gomez de Salazar, E; Alvarez-Cuesta, E

    2013-07-01

    Desensitization to antineoplastic agents is becoming a standard of care. Efforts to establish and improve these techniques are being made at many institutions. Our aims are to evaluate a new rapid desensitization protocol designed to be shorter (approximately 4 h) and safer (reducing hazardous drugs exposure risks) and to assess the oxaliplatin-specific immunoglobulin E (IgE) as a novel diagnostic tool. Prospective, observational, longitudinal study with patients who, for a 1-year period, suffered reactions to antineoplastic agents and were referred to the Desensitization Program at Ramon y Cajal University Hospital (RCUH). Patients were included or excluded as desensitization candidates after anamnesis, skin testing, risk assessment, and graded challenge. Specific IgE was determined in oxaliplatin-reactive patients. Candidate patients were desensitized using the new RCUH rapid desensitization protocol. Of 189 intravenous rapid desensitizations, 188 were successfully accomplished in the 23 patients who met inclusion criteria for desensitization (of 58 referred patients). No breakthrough reactions occurred in 94% of desensitizations, and most breakthrough reactions were mild. In 10 oxaliplatin-reactive patients, 38 desensitizations were successfully accomplished. Sensitivity for oxaliplatin-specific IgE was 38% (0.35UI/l cutoff point) and 54% (0.10UI/l cutoff point); specificity was 100% for both cutoff points. In the hands of a Desensitization Program, managed by drug desensitization experts, this new protocol has proven an effective therapeutic tool for hypersensitivity to several antineoplastic agents (oxaliplatin, carboplatin, paclitaxel, docetaxel, cyclophosphamide, and rituximab); moreover, it improves safety handling of hazardous drugs. We report the first large series of oxaliplatin desensitizations. Oxaliplatin-specific IgE determination could be helpful. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Two novel plasma diagnostic tools: fiber sensors and phase conjugation

    International Nuclear Information System (INIS)

    Jahoda, F.C.

    1985-01-01

    A rapidly developing technology (single-mode optical fiber sensors) and recent fundamental research in nonlinear optics (phase conjugation) both offer opportunities for novel plasma diagnostics. Single-mode fiber sensors can replace electrical wire probes for current and magnetic field measurements with advantages in voltage insulation requirements, electromagnetic noise immunity, much greater bandwidth, and some configuration flexibility. Faraday rotation measurements through fibers wound on the ZT-40M RFP have demonstrated quantitative results, but competing linear birefringence effects still hinder independent interpretation. Twisted fiber may solve this problem. Optical phase conjugation (in which a phase reversed copy of a laser beam is generated) allows real time distortion corrections in laser diagnostics. Self-pumped phase conjugation in BaTiO 3 improves the quality of phase conjugation imagery and greatly simplifies experimentation directed toward plasma diagnostics. Our initial applications are a) time-differential refractometry with high spatial resolution and b) intracavity absorption Zeeman spectroscopy

  5. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Full Text Available Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Resumo: Objetivo: Avaliar o teste QuickVue® RSV Test Kit (QUIDEL Corp, CA, EUA para o diagn

  6. TFTR diagnostic vacuum controller

    International Nuclear Information System (INIS)

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller

  7. Structured diagnostic imaging in patients with multiple trauma

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Rieger, J.; Rock, C.; Pfeifer, K.J.; Reiser, M.; Kanz, K.G.

    2002-01-01

    Purpose. Development of a concept for structured diagnostic imaging in patients with multiple trauma.Material and methods. Evaluation of data from a prospective trial with over 2400 documented patients with multiple trauma. All diagnostic and therapeutic steps, primary and secondary death and the 90 days lethality were documented.Structured diagnostic imaging of multiple injured patients requires the integration of an experienced radiologist in an interdisciplinary trauma team consisting of anesthesia, radiology and trauma surgery. Radiology itself deserves standardized concepts for equipment, personnel and logistics to perform diagnostic imaging for a 24-h-coverage with constant quality.Results. This paper describes criteria for initiation of a shock room or emergency room treatment, strategies for documentation and interdisciplinary algorithms for the early clinical care coordinating diagnostic imaging and therapeutic procedures following standardized guidelines. Diagnostic imaging consists of basic diagnosis, radiological ABC-rule, radiological follow-up and structured organ diagnosis using CT. Radiological trauma scoring allows improved quality control of diagnosis and therapy of multiple injured patients.Conclusion. Structured diagnostic imaging of multiple injured patients leads to a standardization of diagnosis and therapy and ensures constant process quality. (orig.) [de

  8. Multidetector CT: a new gold standard in the diagnosis of pulmonary embolism? State of the art and diagnostic algorithms

    International Nuclear Information System (INIS)

    Russo, Vincenzo; Piva, Tommaso; Lovato, Luigi; Fattori, Rossella; Gavelli, Giampaolo

    2005-01-01

    Purpose: From the early 90s, spiral CT technology has considerably changed the diagnostic capability of Pulmonary Embolism (PE), giving a direct vision of intravascular thrombi. Further technological progress has straightened its diagnostic impact leading to an essential role in clinical practice. The advent of Multi-Detector CT (MDCT) has subsequently increased the reliability of this technique to the point of undermining the role of pulmonary angiography as the gold standard and occupying a central position in diagnostic algorithms. The aim of this paper is to appraise this evolution by means of a meta-analysis of the relevant literature from 1995 to 2004. Results: The review of the literature showed the sensitivity and specificity of CT to have increased from 37-94% and 91-100% (single detector CT) to 87-94% and 94-100% (4-channel multidetector CT), especially thanks to the possibility of depicting subsegmental clots, with an interobserver agreement of 0.63-0.94 (k). Conclusions: CT is one of the most reliable and effective methods in the diagnosis is PE, with the advantage of being extremely fast and providing alternative diagnoses. Recent improvements in MDCT technology confers the highest value of diagnostic accuracy with respect to other imaging modalities such as scintigraphy, angiography, MRI, D-dimer essay and Doppler US [it

  9. Measured parental height in Turner syndrome-a valuable but underused diagnostic tool.

    Science.gov (United States)

    Ouarezki, Yasmine; Cizmecioglu, Filiz Mine; Mansour, Chourouk; Jones, Jeremy Huw; Gault, Emma Jane; Mason, Avril; Donaldson, Malcolm D C

    2018-02-01

    Early diagnosis of Turner syndrome (TS) is necessary to facilitate appropriate management, including growth promotion. Not all girls with TS have overt short stature, and comparison with parental height (Ht) is needed for appropriate evaluation. We examined both the prevalence and diagnostic sensitivity of measured parental Ht in a dedicated TS clinic between 1989 and 2013. Lower end of parental target range (LTR) was calculated as mid-parental Ht (correction factor 12.5 cm minus 8.5 cm) and converted to standard deviation scores (SDS) using UK 1990 data, then compared with patient Ht SDS at first accurate measurement aged > 1 year. Information was available in 172 girls of whom 142 (82.6%) were short at first measurement. However, both parents had been measured in only 94 girls (54.6%). In 92 of these girls age at measurement was 6.93 ± 3.9 years, Ht SDS vs LTR SDS - 2.63 ± 0.94 vs - 1.77 ± 0.81 (p Turner syndrome are short in relation to parental heights, with untreated final height approximately 20 cm below female population mean. • Measured parental height is more accurate than reported height. What is New: • In a dedicated Turner clinic, there was 85% sensitivity when comparing patient height standard deviation score at first accurate measurement beyond 1 year of age with the lower end of the parental target range standard deviation. • However, measured height in both parents had been recorded in only 54.6% of the Turner girls attending the clinic. This indicates the need to improve the quality of growth assessment in tertiary care.

  10. Real-time Modelling, Diagnostics and Optimised MPPT for Residential PV Systems

    DEFF Research Database (Denmark)

    Sera, Dezso

    responsible for yield-reduction of residential photovoltaic systems. Combining the model calculations with measurements, a method to detect changes in the panels’ series resistance based on the slope of the I − V curve in the vicinity of open-circuit conditions and scaled to Standard Test Conditions (STC......The work documented in the thesis has been focused into two main sections. The first part is centred around Maximum Power Point Tracking (MPPT) techniques for photovoltaic arrays, optimised for fast-changing environmental conditions, and is described in Chapter 2. The second part is dedicated...... to diagnostic functions as an additional tool to maximise the energy yield of photovoltaic arrays (Chapter 4). Furthermore, mathematical models of PV panels and arrays have been developed and built (detailed in Chapter 3) for testing MPPT algorithms, and for diagnostic purposes. In Chapter 2 an overview...

  11. A revolution in diagnostic imaging.

    Science.gov (United States)

    Mamula, Paul W

    2003-03-01

    In November 1966, Sandy Koufax, the star left-handed pitcher of the Los Angeles Dodgers, retired after spending his final season coping with traumatic arthritis in his elbow, the compounded effects of a sliding injury to his pitching arm the previous season and 12 years of hard throwing.1 Had his career begun a few years later, he might have been able to benefit from the advances in diagnostic imaging and treatment that were introduced at that time. Modern arthroscopy and computed tomography (CT) did not become available until the mid 1970s,2 and the first elbow reconstruction was done by Frank Jobe, MD, about 10 years after Koufax retired.1 Arthroscopy was first used as a diagnostic tool, but it later became a surgical tool, affecting treatment of knees, then, later, shoulders. Since 1973, when The Physician and Sportsmedicine was launched, we have witnessed a revolution in diagnostic imaging and are continuing to see an evolution of modalities.

  12. Open source tools for standardized privacy protection of medical images

    Science.gov (United States)

    Lien, Chung-Yueh; Onken, Michael; Eichelberg, Marco; Kao, Tsair; Hein, Andreas

    2011-03-01

    In addition to the primary care context, medical images are often useful for research projects and community healthcare networks, so-called "secondary use". Patient privacy becomes an issue in such scenarios since the disclosure of personal health information (PHI) has to be prevented in a sharing environment. In general, most PHIs should be completely removed from the images according to the respective privacy regulations, but some basic and alleviated data is usually required for accurate image interpretation. Our objective is to utilize and enhance these specifications in order to provide reliable software implementations for de- and re-identification of medical images suitable for online and offline delivery. DICOM (Digital Imaging and Communications in Medicine) images are de-identified by replacing PHI-specific information with values still being reasonable for imaging diagnosis and patient indexing. In this paper, this approach is evaluated based on a prototype implementation built on top of the open source framework DCMTK (DICOM Toolkit) utilizing standardized de- and re-identification mechanisms. A set of tools has been developed for DICOM de-identification that meets privacy requirements of an offline and online sharing environment and fully relies on standard-based methods.

  13. Diagnostic accuracy of physical examination tests of the ankle/foot complex: a systematic review.

    Science.gov (United States)

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren; Cook, Chad

    2013-08-01

    Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. 3a.

  14. Three novel software tools for ASDEX Upgrade

    International Nuclear Information System (INIS)

    Martinov, S.; Löbhard, T.; Lunt, T.; Behler, K.; Drube, R.; Eixenberger, H.; Herrmann, A.; Lohs, A.; Lüddecke, K.; Merkel, R.; Neu, G.; ASDEX Upgrade Team; MPCDF Garching

    2016-01-01

    Highlights: • Key features of innovative software tools for data visualization and inspection are presented to the nuclear fusion research community. • 3D animation of experiment geometry together with diagnostic data and images allow better understanding of measurements and influence of machine construction details behind them. • Multi-video viewer with fusion relevant image manipulation abilities and event database features allows faster and better decision making from video streams coming from various plasma and machine diagnostics. • Platform independant Web technologies enable the inspection of diagnostic raw signals with virtually any kind of display device. - Abstract: Visualization of measurements together with experimental settings is a general subject in experiments analysis. The complex engineering design, 3D geometry, and manifold of diagnostics in larger fusion research experiments justify the development of special analysis and visualization programs. Novel ASDEX Upgrade (AUG) software tools bring together virtual navigation through 3D device models and advanced play-back and interpretation of video streams from plasma discharges. A third little tool allows the web-based platform independent observation of real-time diagnostic signals. While all three tools stem from spontaneous development ideas and are not considered mission critical for the operation of a fusion device, they with time and growing completeness shaped up as valuable helpers to visualize acquired data in fusion research. A short overview on the goals, the features, and the design as well as the operation of these tools is given in this paper.

  15. Three novel software tools for ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Martinov, S. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, D-85748 Garching bei München (Germany); Löbhard, T. [Conovum GmbH & Co. KG, Nymphenburger Straße 13, D-80335 München (Germany); Lunt, T. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, D-85748 Garching bei München (Germany); Behler, K., E-mail: karl.behler@ipp.mpg.de [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, D-85748 Garching bei München (Germany); Drube, R.; Eixenberger, H.; Herrmann, A.; Lohs, A. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, D-85748 Garching bei München (Germany); Lüddecke, K. [Unlimited Computer Systems GmbH, Seeshaupterstr. 15, D-82393 Iffeldorf (Germany); Merkel, R.; Neu, G.; ASDEX Upgrade Team [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, D-85748 Garching bei München (Germany); MPCDF Garching [Max Planck Compu ting and Data Facility, Boltzmannstr. 2, D-85748 Garching (Germany)

    2016-11-15

    Highlights: • Key features of innovative software tools for data visualization and inspection are presented to the nuclear fusion research community. • 3D animation of experiment geometry together with diagnostic data and images allow better understanding of measurements and influence of machine construction details behind them. • Multi-video viewer with fusion relevant image manipulation abilities and event database features allows faster and better decision making from video streams coming from various plasma and machine diagnostics. • Platform independant Web technologies enable the inspection of diagnostic raw signals with virtually any kind of display device. - Abstract: Visualization of measurements together with experimental settings is a general subject in experiments analysis. The complex engineering design, 3D geometry, and manifold of diagnostics in larger fusion research experiments justify the development of special analysis and visualization programs. Novel ASDEX Upgrade (AUG) software tools bring together virtual navigation through 3D device models and advanced play-back and interpretation of video streams from plasma discharges. A third little tool allows the web-based platform independent observation of real-time diagnostic signals. While all three tools stem from spontaneous development ideas and are not considered mission critical for the operation of a fusion device, they with time and growing completeness shaped up as valuable helpers to visualize acquired data in fusion research. A short overview on the goals, the features, and the design as well as the operation of these tools is given in this paper.

  16. Constructive Technology Assessment (CTA) as a tool in coverage with evidence development: the case of the 70-gene prognosis signature for breast cancer diagnostics

    NARCIS (Netherlands)

    Retel, Valesca; Retèl, Valesca P.; Bueno-de-Mesquita, Jolien M.; Hummel, J. Marjan; van de Vijver, Marc J.; Douma, Kirsten F.L.; Karsenberg, Kim; van Dam, Frits S.A.M.; van Krimpen, Cees; Bellot, Frank E.; Roumen, Rudi M.H.; Linn, Sabine C.; van Harten, Willem H.

    2009-01-01

    Objectives: Constructive Technology Assessment (CTA) is a means to guide early implementation of new developments in society, and can be used as an evaluation tool for Coverage with Evidence Development (CED). We used CTA for the introduction of a new diagnostic test in the Netherlands, the 70-gene

  17. Constructive Technology Assessment (CTA) as a tool in Coverage with Evidence Development: The case of the 70-gene prognosis signature for breast cancer diagnostics

    NARCIS (Netherlands)

    Retèl, Valesca P.; Bueno-de-Mesquita, Jolien M.; Hummel, Marjan J. M.; van de Vijver, Marc J.; Douma, Kirsten F. L.; Karsenberg, Kim; van Dam, Frits S. A. M.; van Krimpen, Cees; Bellot, Frank E.; Roumen, Rudi M. H.; Linn, Sabine C.; van Harten, Wim H.

    2009-01-01

    Objectives: Constructive Technology Assessment (CTA) is a means to guide early implementation of new developments in society, and can be used as an evaluation tool for Coverage with Evidence Development (CED). We used CTA for the introduction of a new diagnostic test in the Netherlands, the 70-gene

  18. Auditory brainstem response as a diagnostic tool for patients suffering from schizophrenia, attention deficit hyperactivity disorder, and bipolar disorder: protocol.

    Science.gov (United States)

    Wahlström, Viktor; Åhlander, Fredrik; Wynn, Rolf

    2015-02-12

    Psychiatric disorders, such as schizophrenia, attention deficit hyperactivity disorder (ADHD), and bipolar disorder, may sometimes be difficult to diagnose. There is a great need for a valid and reliable diagnostic tool to aid clinicians in arriving at the diagnoses in a timely and accurate manner. Prior studies have suggested that patients suffering from schizophrenia and ADHD may process certain sound stimuli in the brainstem in an unusual manner. When these patient groups have been examined with the electrophysiological method of brainstem audiometry, some studies have found illness-specific aberrations. Such aberrations may also exist for patients suffering from bipolar disorder. In this study, we will examine whether the method of brainstem audiometry can be used as a diagnostic tool for patients suffering from schizophrenia, ADHD, and bipolar disorder. The method includes three steps: (1) auditory stimulation with specific sound stimuli, (2) simultaneous measurement of brainstem activity, and (3) automated interpretation of the resulting brain stem audiograms with data-based signal analysis. We will compare three groups of 12 individuals with confirmed diagnoses of schizophrenia, ADHD, or bipolar disorder with 12 healthy subjects under blinded conditions for a total of 48 participants. The extent to which the method can be used to reach the correct diagnosis will be investigated. The project is now in a recruiting phase. When all patients and controls have been recruited and the measurements have been performed, the data will be analyzed according to a previously arranged algorithm. We expect the recruiting phase and measurements to be completed in early 2015, the analyses to be performed in mid-2015, and the results of the study to be published in early 2016. If the results support previous findings, this will lend strength to the idea that brainstem audiometry can offer objective diagnostic support for patients suffering from schizophrenia, ADHD, and

  19. Use of urethral catheters for diagnostic peritoneal lavage in blunt ...

    African Journals Online (AJOL)

    Background: Diagnostic peritoneal lavage (DPL) has been reported to be a reliable diagnostic tool in assessing the need for liparotomy in blunt abdominal trauma (BAT) with a diagnostic accuracy of more thin 95% when using a peritoneal lavage catheter (PLC). The aim of this study was to determine the diagnostic ...

  20. Automated innovative diagnostic, data management and communication tool, for improving malaria vector control in endemic settings.

    Science.gov (United States)

    Vontas, John; Mitsakakis, Konstantinos; Zengerle, Roland; Yewhalaw, Delenasaw; Sikaala, Chadwick Haadezu; Etang, Josiane; Fallani, Matteo; Carman, Bill; Müller, Pie; Chouaïbou, Mouhamadou; Coleman, Marlize; Coleman, Michael

    2016-01-01

    Malaria is a life-threatening disease that caused more than 400,000 deaths in sub-Saharan Africa in 2015. Mass prevention of the disease is best achieved by vector control which heavily relies on the use of insecticides. Monitoring mosquito vector populations is an integral component of control programs and a prerequisite for effective interventions. Several individual methods are used for this task; however, there are obstacles to their uptake, as well as challenges in organizing, interpreting and communicating vector population data. The Horizon 2020 project "DMC-MALVEC" consortium will develop a fully integrated and automated multiplex vector-diagnostic platform (LabDisk) for characterizing mosquito populations in terms of species composition, Plasmodium infections and biochemical insecticide resistance markers. The LabDisk will be interfaced with a Disease Data Management System (DDMS), a custom made data management software which will collate and manage data from routine entomological monitoring activities providing information in a timely fashion based on user needs and in a standardized way. The ResistanceSim, a serious game, a modern ICT platform that uses interactive ways of communicating guidelines and exemplifying good practices of optimal use of interventions in the health sector will also be a key element. The use of the tool will teach operational end users the value of quality data (relevant, timely and accurate) to make informed decisions. The integrated system (LabDisk, DDMS & ResistanceSim) will be evaluated in four malaria endemic countries, representative of the vector control challenges in sub-Saharan Africa, (Cameroon, Ivory Coast, Ethiopia and Zambia), highly representative of malaria settings with different levels of endemicity and vector control challenges, to support informed decision-making in vector control and disease management.

  1. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Zagzebski, J. [University of Wisconsin (United States)

    2016-06-15

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  2. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    International Nuclear Information System (INIS)

    Zagzebski, J.

    2016-01-01

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  3. Monitoring of ionospheric turbulence spatial features by SEE diagnostic tools

    Science.gov (United States)

    Sergeev, E. N.; Boiko, G. N.; Shvarts, M. M.; Grach, S. M.; Kotov, P. V.

    Spatial features of HF pumped ionospheric F-region are investigated experimentally at the SURA facility by means of the stimulated electromagnetic emission (SEE). SEE, recall, appears as a result of conversion (or scattering) of HF pump-driven plasma waves off the geomagnetic field aligned electron density irregularities (striations). A specially designed pumping scheme was elaborated to study an influence of the perturbations of the electron density and temperature, created by powerful pump wave at frequency f_h and occupying quite extended altitude range (range-I), on spectral and temporal evolution of the diagnostic SEE (DSEE) generated by a weak continuous or pulse diagnostic wave at a frequency f_d in an altitude range-II, spatially shifted from the centre of the range-I. New two-channel digital receiver allowed to analyze the SEE from both ranges (around both frequencies f_h and f_d) simultaneously. A combination of the SEE diagnostics and computer simulations allowed to study:% (a) dependences of striation spectrum and dynamics on the frequency shift |f_h-f_d| (which can be easily translated to the altitude displacement), powers of the pump and diagnostic waves, offsets of the frequencies f_h and f_d from electron gyroharmonics, and on the daily conditions. It is found that a slow (time scale of 1--10 s) dynamics of DSEE, namely, characteristics of its slow overshoot and undershoot effects are determined by the spectral shape and intensity of the striations at, respectively, the development and relaxation stages. It is shown that the striation spectrum flattens in meter scale range for f_h between 3th and 4th gyroharmonics in comparison with larger f_h, in the centre of the range-I in comparison with its periphery, that the range-I extension increases with its altitude and with a transition from day to night conditions;% (b) an influence of the powerful pumping on ``diagnostic'' HF plasma wave evolution by measurements of growth and decay times of the DSEE

  4. Multidisciplinary molecular diagnostics: the 9th European meeting on molecular diagnostics.

    Science.gov (United States)

    Loonen, Anne J M; Schuurman, Rob; van den Brule, Adriaan J C

    2016-01-01

    This report presents a summary of the 9th European Meeting on Molecular Diagnostics held in Noordwijk, The Netherlands, 14-16 October 2015. This 3-day conference covered many relevant topics in the field of molecular diagnostics in humans, including infectious disease, oncology, outbreak management, population-based cancer screening, standardization and quality control, chronic diseases and pharmacogenetics. Beyond these different areas, shared values are new technologies and novel technical and clinical applications. Approximately 450 participants, the majority coming from European countries, attended the meeting. Besides high quality scientific presentations, more than 35 diagnostic companies presented their latest innovations, altogether in an informal and inspiring scientific ambience.

  5. Survey of Compliance with Radiation Protection Standards in Diagnostic Imaging Centers of Khuzestan Province in 2015

    Directory of Open Access Journals (Sweden)

    farshid mahmoudi

    2017-03-01

    rooms in 32 diagnostic imaging centers in Khuzestan Province, Iran, 2015. The centers were chosen through random cluster sampling method. The data were obtained using open-ended interview and a checklist designed based on the recommendations of the International Commission for Radiation Protection and Atomic Energy Organization of Iran. Results: The compliance rates with regard to radiology room, radiology equipment, darkroom, and radiographer’s protection were 80.76%, 80.47%, 69.28%, and 93.12%, respectively. Maximum and minimum rates of compliance with the standards were related to performance of the cassette tray (100% and hopper status (25%, respectively. Comparison of public and private imaging centers in terms of safety standards showed no significant differences (P>0.05.Conclusion: The observance of the radiation protection standards in Khuzestan Province was in a relativly desirable condition. However, there are some shortcomings in compliance with the principles of protection in the darkroom. In this regard, with recommend adopting protection measures such as timelyreplacement of processing solution, appropriate ventilation of darkroom, provisionof protection equipment and appliances, and protection training required for entering the darkroom.

  6. Nanotechnology solutions for Alzheimer's disease: advances in research tools, diagnostic methods and therapeutic agents.

    Science.gov (United States)

    Nazem, Amir; Mansoori, G Ali

    2008-03-01

    A century of research has passed since the discovery and definition of Alzheimer's disease (AD), the primary common dementing disorder worldwide. However, AD lacks definite diagnostic approaches and effective cure at the present. Moreover, the currently available diagnostic tools are not sufficient for an early screening of AD in order to start preventive approaches. Recently the emerging field of nanotechnology has promised new techniques to solve some of the AD challenges. Nanotechnology refers to the techniques of designing and manufacturing nanosize (1-100 nm) structures through controlled positional and/or self-assembly of atoms and molecules. In this report, we present the promises that nanotechnology brings in research on the AD diagnosis and therapy. They include its potential for the better understanding of the AD root cause molecular mechanisms, AD's early diagnoses, and effective treatment. The advances in AD research offered by the atomic force microscopy, single molecule fluorescence microscopy and NanoSIMS microscopy are examined here. In addition, the recently proposed applications of nanotechnology for the early diagnosis of AD including bio-barcode assay, localized surface plasmon resonance nanosensor, quantum dot and nanomechanical cantilever arrays are analyzed. Applications of nanotechnology in AD therapy including neuroprotections against oxidative stress and anti-amyloid therapeutics, neuroregeneration and drug delivery beyond the blood brain barrier (BBB) are discussed and analyzed. All of these applications could improve the treatment approach of AD and other neurodegenerative diseases. The complete cure of AD may become feasible by a combination of nanotechnology and some other novel approaches, like stem cell technology.

  7. Reticulocyte haemoglobin content as a diagnostic tool for iron ...

    African Journals Online (AJOL)

    IDA) in ill children is complicated by the unreliability of serum ferritin (S-ferritin). The presence of a microcytic, hypochromic anaemia suggests IDA but is not specific. There is a need for a diagnostic test that will be accessible, cost-effective and ...

  8. Fourier transform-infrared spectroscopy as a diagnostic tool for mosquito coil smoke inhalation toxicity in Swiss Albino mice

    Science.gov (United States)

    Anusha, Chidambaram; Sankar, Renu; Varunkumar, Krishnamoorthy; Sivasindhuja, Gnanasambantham; Ravikumar, Vilwanathan

    2017-12-01

    The goal of this study is to establish Fourier transform-infrared (FTIR) spectroscopy as a diagnostic tool for allethrin-based mosquito coil smoke inhalation induced toxicity in mice. Primarily, we confirmed mosquito coil smoke inhalation toxicity in mice via reduced the body, organ weight and major vital organ tissue morphological structure changes. Furthermore, FTIR spectra was collected from control and mosquito coil smoke inhalation (8 h per day for 30 days) mice various tissues like liver, kidney, lung, heart and brain, to investigate the functional groups and their corresponding biochemical content variations. The FTIR spectra result shown major bio macromolecules such as protein and lipid functional peaks were shifted (decreased) in the mosquito coil smoke inhalation group as compared to control. The drastic peak shift was noticed in the liver, kidney followed by lung and brain. It is therefore concluded that the FTIR spectroscopy can be a successful detection tool in mosquito coil smoke inhalation toxicity.

  9. Automated diagnostics scoping study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Quadrel, R.W.; Lash, T.A.

    1994-06-01

    The objective of the Automated Diagnostics Scoping Study was to investigate the needs for diagnostics in building operation and to examine some of the current technologies in automated diagnostics that can address these needs. The study was conducted in two parts. In the needs analysis, the authors interviewed facility managers and engineers at five building sites. In the technology survey, they collected published information on automated diagnostic technologies in commercial and military applications as well as on technologies currently under research. The following describe key areas that the authors identify for the research, development, and deployment of automated diagnostic technologies: tools and techniques to aid diagnosis during building commissioning, especially those that address issues arising from integrating building systems and diagnosing multiple simultaneous faults; technologies to aid diagnosis for systems and components that are unmonitored or unalarmed; automated capabilities to assist cause-and-effect exploration during diagnosis; inexpensive, reliable sensors, especially those that expand the current range of sensory input; technologies that aid predictive diagnosis through trend analysis; integration of simulation and optimization tools with building automation systems to optimize control strategies and energy performance; integration of diagnostic, control, and preventive maintenance technologies. By relating existing technologies to perceived and actual needs, the authors reached some conclusions about the opportunities for automated diagnostics in building operation. Some of a building operator`s needs can be satisfied by off-the-shelf hardware and software. Other needs are not so easily satisfied, suggesting directions for future research. Their conclusions and suggestions are offered in the final section of this study.

  10. A Tool Measuring Remaining Thickness of Notched Acoustic Cavities in Primary Reaction Control Thruster NDI Standards

    Science.gov (United States)

    Sun, Yushi; Sun, Changhong; Zhu, Harry; Wincheski, Buzz

    2006-01-01

    Stress corrosion cracking in the relief radius area of a space shuttle primary reaction control thruster is an issue of concern. The current approach for monitoring of potential crack growth is nondestructive inspection (NDI) of remaining thickness (RT) to the acoustic cavities using an eddy current or remote field eddy current probe. EDM manufacturers have difficulty in providing accurate RT calibration standards. Significant error in the RT values of NDI calibration standards could lead to a mistaken judgment of cracking condition of a thruster under inspection. A tool based on eddy current principle has been developed to measure the RT at each acoustic cavity of a calibration standard in order to validate that the standard meets the sample design criteria.

  11. Selective use of diagnostic laparoscopy in patients with suspected appendicitis

    NARCIS (Netherlands)

    van den Broek, W. T.; Bijnen, A. B.; van Eerten, P. V.; de Ruiter, P.; Gouma, D. J.

    2000-01-01

    BACKGROUND: Diagnostic laparoscopy has been introduced as a new diagnostic tool for patients with acute appendicitis. We performed diagnostic laparoscopy when the clinical diagnosis of appendicitis was in doubt. The aims of this study were to evaluate this strategy and to analyze the efficacy of

  12. Software Users Manual (SUM): Extended Testability Analysis (ETA) Tool

    Science.gov (United States)

    Maul, William A.; Fulton, Christopher E.

    2011-01-01

    This software user manual describes the implementation and use the Extended Testability Analysis (ETA) Tool. The ETA Tool is a software program that augments the analysis and reporting capabilities of a commercial-off-the-shelf (COTS) testability analysis software package called the Testability Engineering And Maintenance System (TEAMS) Designer. An initial diagnostic assessment is performed by the TEAMS Designer software using a qualitative, directed-graph model of the system being analyzed. The ETA Tool utilizes system design information captured within the diagnostic model and testability analysis output from the TEAMS Designer software to create a series of six reports for various system engineering needs. The ETA Tool allows the user to perform additional studies on the testability analysis results by determining the detection sensitivity to the loss of certain sensors or tests. The ETA Tool was developed to support design and development of the NASA Ares I Crew Launch Vehicle. The diagnostic analysis provided by the ETA Tool was proven to be valuable system engineering output that provided consistency in the verification of system engineering requirements. This software user manual provides a description of each output report generated by the ETA Tool. The manual also describes the example diagnostic model and supporting documentation - also provided with the ETA Tool software release package - that were used to generate the reports presented in the manual

  13. Research Review: Test-retest reliability of standardized diagnostic interviews to assess child and adolescent psychiatric disorders: a systematic review and meta-analysis.

    Science.gov (United States)

    Duncan, Laura; Comeau, Jinette; Wang, Li; Vitoroulis, Irene; Boyle, Michael H; Bennett, Kathryn

    2018-02-19

    A better understanding of factors contributing to the observed variability in estimates of test-retest reliability in published studies on standardized diagnostic interviews (SDI) is needed. The objectives of this systematic review and meta-analysis were to estimate the pooled test-retest reliability for parent and youth assessments of seven common disorders, and to examine sources of between-study heterogeneity in reliability. Following a systematic review of the literature, multilevel random effects meta-analyses were used to analyse 202 reliability estimates (Cohen's kappa = ҡ) from 31 eligible studies and 5,369 assessments of 3,344 children and youth. Pooled reliability was moderate at ҡ = .58 (CI 95% 0.53-0.63) and between-study heterogeneity was substantial (Q = 2,063 (df = 201), p reliability varied across informants for specific types of psychiatric disorder (ҡ = .53-.69 for parent vs. ҡ = .39-.68 for youth) with estimates significantly higher for parents on attention deficit hyperactivity disorder, oppositional defiant disorder and the broad groupings of externalizing and any disorder. Reliability was also significantly higher in studies with indicators of poor or fair study methodology quality (sample size reliability of SDIs and the usefulness of these tools in both clinical and research contexts. Potential remedies include the introduction of standardized study and reporting requirements for reliability studies, and exploration of other approaches to assessing and classifying child and adolescent psychiatric disorder. © 2018 Association for Child and Adolescent Mental Health.

  14. It's time to change perspective! New diagnostic tools for lateral elbow pain.

    Science.gov (United States)

    Arrigoni, P; Cucchi, D; Menon, A; Randelli, P

    2017-12-01

    The presence of intra-articular findings that may complement the extra-articular pathology in lateral epicondilytis has been suggested, and a role for minor instability of the elbow as part of the causative process of this disease has been postulated. This study was designed to describe two new clinical tests, aimed at detecting intra-articular pathology in patients affected by recalcitrant lateral epicondylitis and investigate their diagnostic performance. Ten patients suffering of atraumatic lateral elbow pain unresponsive to conservative treatment were considered in this study. Two clinical tests were developed and administrated prior to arthroscopy: Supination and Antero-Lateral pain Test (SALT); Posterior Elbow Pain by Palpation-Extension of the Radiocapitellar joint (PEPPER). Sensitivity, specificity, predictive values and accuracy of SALT and PEPPER as diagnostic tests for seven intra-articular findings were calculated. In 90% of the patients, at least one test was positive. All patients with signs of lateral ligamentous patholaxity or intra-articular abnormal findings had a positive response to at least one of the two tests. SALT proved to have a high sensitivity but a low specificity and is accurate in detecting the presence of intra-articular abnormal findings, especially synovitis. PEPPER test was sensible, specific and accurate in the detection of radial head chondropathy. Two new diagnostic tests (SALT and PEPPER) were specifically designed to evoke pain from intra-articular structures. These tests could be a valid support in the diagnostic algorithm of recalcitrant lateral elbow pain. Positive findings may be indicative of a minor instability of the lateral elbow condition. Diagnostic study, development of diagnostic criteria on basis of consecutive patients, level II.

  15. [Assessment of IDC-Pal as a Diagnostic Tool for Family Physicians to Identify Patients with Complex Palliative Care Needs in Germany: a Pilot Study].

    Science.gov (United States)

    Comino, María Rosa Salvador; Garcia, Victor Regife; López, Maria Auxiliadora Fernández; Feddersen, Berend; Roselló, María Luisa Martin; Sanftenberg, Linda; Schelling, Jörg

    2017-07-11

    Background Palliative medicine is an essential component of the health care system. Basic palliative care should be provided by primary care services (family physician and home nursing) with palliative-medical basic qualification. Often it is very difficult to identify patients that would profit from a specialized palliative care team. For the evaluation of the case complexity of a palliative patient, we present a Spanish diagnostic tool IDC-Pal, which tries to specify when, why and where a palliative patient should be referred. The aims of this study were the translation and cultural adaptation of the diagnostic tool for complexity in palliative care IDC-Pal to the German language, and the measurement of its feasibility and face validity. Methods During the first phase, a forward-backward translation with linguistic and cultural adaptation of the tool IDC-Pal as well as the validation of its content by a review committee was performed. During the second phase, the preliminary version of the tool was tested by 38 family physicians that were asked for a qualitative assessment using a 10-points Likert scale (1 = "strongly disagree" and 10 = "totally agree"). Finally, a definitive version was developed. Results The translation and adaptation were achieved without major problems. Both feasibility and apparent validity of the tool IDC-Pal were rated as high. The mean response in the Likert scale was 7.79, with a SD of 0.36. Participants strongly agreed on the apparent validity of the tool with a mean of 7.82 and a SD of 0.26 and on its feasibility with a mean of 7.79, and a SD of 0.39. Conclusions A conceptually, culturally and linguistically equivalent version of the original instrument IDC-Pal was obtained. German family physicians agreed on the usability of IDC-Pal as a tool for rating the case complexity of palliative patients. These results indicate that physicians in Bavaria and eventually in Germany could benefit of the full validation of IDC-Pal. © Georg Thieme

  16. Pig producer perspectives on the use of meat inspection as an animal health and welfare diagnostic tool in the Republic of Ireland and Northern Ireland.

    Science.gov (United States)

    Devitt, Catherine; Boyle, Laura; Teixeira, D L; O'Connell, N E; Hawe, M; Hanlon, Alison

    2015-01-01

    Currently, there is growing interest in developing ante and post mortem meat inspection (MI) to incorporate measures of pig health and welfare for use as a diagnostic tool on pig farms. However, the success of the development of the MI process requires stakeholder engagement with the process. Knowledge gaps and issues of trust can undermine the effective exchange and utilisation of information across the supply chain. A social science research methodology was employed to establish stakeholder perspectives towards the development of MI to include measures of pig health and welfare. In this paper the findings of semi-structured telephone interviews with 18 pig producers from the Republic of Ireland and Northern Ireland are presented. Producers recognised the benefit of the utilisation of MI data as a health and welfare diagnostic tool. This acknowledgment, however, was undermined for some by dissatisfaction with the current system of MI information feedback, by trust and fairness concerns, and by concerns regarding the extent to which data would be used in the producers' interests. Tolerance of certain animal welfare issues may also have a negative impact on how producers viewed the potential of MI data. The private veterinary practitioner was viewed as playing a vital role in assisting them with the interpretation of MI data for herd health planning. The development of positive relationships based on trust, commitment and satisfaction across the supply chain may help build a positive environment for the effective utilisation of MI data in improving pig health and welfare. The utilisation of MI as a diagnostic tool would benefit from the development of a communication strategy aimed at building positive relationships between stakeholders in the pig industry.

  17. Review of Mycobacteriumavium subsp. paratuberculosis antigen candidates with diagnostic potential

    DEFF Research Database (Denmark)

    Mikkelsen, Heidi; Aagaard, Claus; Nielsen, Søren Saxmose

    2011-01-01

    antigens, heat shock antigens and hypothetical antigens. Strategies for evaluation of novel antigen candidates are discussed critically. Relatively few of the described antigens were evaluated for their use in CMI based diagnostic assays and so far, no obvious candidate has been identified...... to development of antibodies and shedding of detectable amounts of MAP. At present, available diagnostic assays are limited by the lack of MAP specific antigens included in these assays resulting in poor specificity. The objective of this review is to provide a systematic overview of diagnostic MAP antigen...... faeces; however, these diagnostic tools are often not applicable until years after infection. Detection of MAP specific cell-mediated immune (CMI) responses can serve as an alternative and be implemented in a diagnostic tool. CMI responses can be measured at an early stage of infection, prior...

  18. Diagnostic imaging and radiation therapy equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-05-01

    This is the third edition of CSA Standard C22.2 No. 114 (now CAN/CSA-C22.2 No. 114), which is one of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This edition marks an important shift towards harmonization of Canadian requirements with those of the European community and the United States. Also important to this edition is the expansion of its scope to include the complete range of diagnostic imaging and radiation therapy equipment, rather than solely radiation-emitting equipment. In so doing, equipment previously addressed by CSA Standard C22.2 No. 125, Electromedical Equipment, specifically lasers for medical applications and diagnostic ultrasound units, is now dealt with in the new edition. By virtue of this expanded scope, many of the technical requirements in the electromedical equipment standard have been introduced to the new edition, thereby bringing CSA Standard C22.2 No. 114 up to date. 14 tabs., 16 figs.

  19. Diagnostic imaging and radiation therapy equipment

    International Nuclear Information System (INIS)

    1990-05-01

    This is the third edition of CSA Standard C22.2 No. 114 (now CAN/CSA-C22.2 No. 114), which is one of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This edition marks an important shift towards harmonization of Canadian requirements with those of the European community and the United States. Also important to this edition is the expansion of its scope to include the complete range of diagnostic imaging and radiation therapy equipment, rather than solely radiation-emitting equipment. In so doing, equipment previously addressed by CSA Standard C22.2 No. 125, Electromedical Equipment, specifically lasers for medical applications and diagnostic ultrasound units, is now dealt with in the new edition. By virtue of this expanded scope, many of the technical requirements in the electromedical equipment standard have been introduced to the new edition, thereby bringing CSA Standard C22.2 No. 114 up to date. 14 tabs., 16 figs

  20. Preoperative Decision Making for Nephron-Sparing Procedure in the Renal Mass: Time for Using Standard Tools?

    NARCIS (Netherlands)

    Zondervan, Patricia J.; van Lienden, Krijn P.; van Delden, Otto M.; de La Rosette, Jean J. M. C. H.; Laguna, M. Pilar

    2016-01-01

    To determine if the application of using standard tools on tumor complexity and comorbidity indexes may replace the traditional choice of nephron-sparing procedure (NSP) based on clinical maximal tumor diameter (cMTD), age, and comorbidity. Anatomic complexity scores (PADUA and RENAL) and Charlson

  1. Tracking Progress in Improving Diagnosis: A Framework for Defining Undesirable Diagnostic Events.

    Science.gov (United States)

    Olson, Andrew P J; Graber, Mark L; Singh, Hardeep

    2018-01-29

    Diagnostic error is a prevalent, harmful, and costly phenomenon. Multiple national health care and governmental organizations have recently identified the need to improve diagnostic safety as a high priority. A major barrier, however, is the lack of standardized, reliable methods for measuring diagnostic safety. Given the absence of reliable and valid measures for diagnostic errors, we need methods to help establish some type of baseline diagnostic performance across health systems, as well as to enable researchers and health systems to determine the impact of interventions for improving the diagnostic process. Multiple approaches have been suggested but none widely adopted. We propose a new framework for identifying "undesirable diagnostic events" (UDEs) that health systems, professional organizations, and researchers could further define and develop to enable standardized measurement and reporting related to diagnostic safety. We propose an outline for UDEs that identifies both conditions prone to diagnostic error and the contexts of care in which these errors are likely to occur. Refinement and adoption of this framework across health systems can facilitate standardized measurement and reporting of diagnostic safety.

  2. Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.

    Science.gov (United States)

    Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew

    2012-12-01

    Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.

  3. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Baorong, Yue

    2008-01-01

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  4. A Verification and Validation Tool for Diagnostic Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced diagnostic systems have the potential to improve safety, increase availability, and reduce maintenance costs in aerospace vehicle and a variety of other...

  5. From Provenance Standards and Tools to Queries and Actionable Provenance

    Science.gov (United States)

    Ludaescher, B.

    2017-12-01

    The W3C PROV standard provides a minimal core for sharing retrospective provenance information for scientific workflows and scripts. PROV extensions such as DataONE's ProvONE model are necessary for linking runtime observables in retrospective provenance records with conceptual-level prospective provenance information, i.e., workflow (or dataflow) graphs. Runtime provenance recorders, such as DataONE's RunManager for R, or noWorkflow for Python capture retrospective provenance automatically. YesWorkflow (YW) is a toolkit that allows researchers to declare high-level prospective provenance models of scripts via simple inline comments (YW-annotations), revealing the computational modules and dataflow dependencies in the script. By combining and linking both forms of provenance, important queries and use cases can be supported that neither provenance model can afford on its own. We present existing and emerging provenance tools developed for the DataONE and SKOPE (Synthesizing Knowledge of Past Environments) projects. We show how the different tools can be used individually and in combination to model, capture, share, query, and visualize provenance information. We also present challenges and opportunities for making provenance information more immediately actionable for the researchers who create it in the first place. We argue that such a shift towards "provenance-for-self" is necessary to accelerate the creation, sharing, and use of provenance in support of transparent, reproducible computational and data science.

  6. Tools to Detect Delirium Superimposed on Dementia: A Systematic Review

    Science.gov (United States)

    Morandi, Alessandro; McCurley, Jessica; Vasilevskis, Eduard E.; Fick, Donna M.; Bellelli, Giuseppe; Lee, Patricia; Jackson, James C.; Shenkin, Susan D.; Trabucchi, Marco; Schnelle, John; Inouye, Sharon K.; Ely, Wesley E.; MacLullich, Alasdair

    2012-01-01

    Background Delirium commonly occurs in patients with dementia. Though several tools for detecting delirium exist, it is unclear which are valid in patients with delirium superimposed on dementia. Objectives Identify valid tools to diagnose delirium superimposed on dementia Design We performed a systematic review of studies of delirium tools, which explicitly included patients with dementia. Setting In-hospital patients Participants Studies were included if delirium assessment tools were validated against standard criteria, and the presence of dementia was assessed according to standard criteria that used validated instruments. Measurements PubMed, Embase, and Web of Science databases were searched for articles in English published between January 1960 and January 2012. Results Nine studies fulfilled the selection criteria. Of the total of 1569 patients, 401 had dementia, and 50 had delirium superimposed on dementia. Six delirium tools were evaluated. One studyusing the Confusion Assessment Method (CAM) with 85% patients with dementia showed a high specificity (96–100%) and moderate sensitivity (77%).Two intensive care unit studies that used the CAM for the Intensive Care Unit (CAM-ICU) ICU reported 100% sensitivity and specificity for delirium among 23 dementia patients. One study using electroencephalography reported a sensitivity of 67% and a specificity of 91% among a population with 100% prevalence of dementia. No studies examined potential effects of dementia severity or subtype upon diagnostic accuracy. Conclusions The evidence base on tools for detection of delirium superimposed on dementia is limited, although some existing tools show promise. Further studies of existing or refined tools with larger samples and more detailed characterization of dementia are now required to address the identification of delirium superimposed on dementia. PMID:23039270

  7. The ITER bolometer diagnostic: Status and plans

    International Nuclear Information System (INIS)

    Meister, H.; Giannone, L.; Horton, L. D.; Raupp, G.; Zeidner, W.; Grunda, G.; Kalvin, S.; Fischer, U.; Serikov, A.; Stickel, S.; Reichle, R.

    2008-01-01

    A consortium consisting of four EURATOM Associations has been set up to develop the project plan for the full development of the ITER bolometer diagnostic and to continue urgent R and D activities. An overview of the current status is given, including detector development, line-of-sight optimization, performance analysis as well as the design of the diagnostic components and their integration in ITER. This is complemented by the presentation of plans for future activities required to successfully implement the bolometer diagnostic, ranging from the detector development over diagnostic design and prototype testing to RH tools for calibration.

  8. The ITER bolometer diagnostic: Status and plansa)

    Science.gov (United States)

    Meister, H.; Giannone, L.; Horton, L. D.; Raupp, G.; Zeidner, W.; Grunda, G.; Kalvin, S.; Fischer, U.; Serikov, A.; Stickel, S.; Reichle, R.

    2008-10-01

    A consortium consisting of four EURATOM Associations has been set up to develop the project plan for the full development of the ITER bolometer diagnostic and to continue urgent R&D activities. An overview of the current status is given, including detector development, line-of-sight optimization, performance analysis as well as the design of the diagnostic components and their integration in ITER. This is complemented by the presentation of plans for future activities required to successfully implement the bolometer diagnostic, ranging from the detector development over diagnostic design and prototype testing to RH tools for calibration.

  9. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  10. Translation and validation of Autism Diagnostic Interview-Revised (ADI-R for autism diagnosis in Brazil

    Directory of Open Access Journals (Sweden)

    Michele M. Becker

    2012-03-01

    Full Text Available OBJECTIVE: To translate into Brazilian Portuguese the Autism Diagnostic Interview-Revised (ADI-R, an extremely useful diagnostic tool in autism. METHODS: A case-control study was done to validate the ADI-R. After being translated, the interview was applied in a sample of 20 patients with autism and 20 patients with intellectual disability without autism, in order to obtain the initial psychometric properties. RESULTS: The internal consistency was high, with a of Crombach of 0.967. The validity of criterion had sensitivity and specificity of 100%, having as a gold standard the DSM-IV diagnostic criteria. The interview had high discriminant validity, with higher scores in the group of patients with autism, as well as high interobserver consistency, with median kappa of 0.824. CONCLUSION: The final version of ADI-R had satisfactory psychometric characteristics, indicating good preliminary validation properties. The instrument needs to be applied in bigger samples in other areas of the country.

  11. Trans-identity - the Standards of Diagnostics and Treatment

    Directory of Open Access Journals (Sweden)

    Gessmann H.-V.

    2014-11-01

    Full Text Available German Society for Sexual Research, Academy of Sexual Medicine and Society of Sexology formulated standards for evaluation and treatment of transsexuals. The creation of the standards involved Sophinette Becker, Hartmut A. G. Bosinski, Ulrich Clement, Wolf Eicher, Thomas M. Goerlich, Uwe Hartmann, Götz Kockott, Dieter Langer, Wilhelm E. Preuss, Gunter Schmidt, Alfred Springer, Reinhard Wille. Since 1980, the Federal Republic of Germany has a law on transsexualism, which regulates the right of the individual to change the sex. However, until now there were no specifically defined standards of assessment and treatment of transsexuals. For the first time, in 1979 Harry Benjamin invited the International Medical Association of Germany to revise the standards of medical care for gender dysphoria. The following standards of assessment and treatment of transsexuals have been developed at a conference convened by the German Society for Research Expert Committee under the leadership of Sophinette Becker. The review of currently valid standards for evaluation and treatment of transgender is the subject of this article

  12. Evaluating the diagnostic device DETEC-PC for the thyroid uptakes

    International Nuclear Information System (INIS)

    Alonso Abad, Dolores; Arista Romeu, Eduardo; Alonso Abad, Ariel

    2008-01-01

    A study is presented for evaluating the diagnostic capacity of the DETEC-PC, detection measurement system for the Thyroid Uptakes. A clinical trial was designed for that effect and all the patients included were evaluated using the DETEC-PC and the well-known radioimmunoassay (RIA) standard diagnostic procedure known by acronym RIA. For the Thyroid Uptakes using the DETEC-PC patients received an oral administration of a solution of radioactive iodine. The radioactive substance is attracted chemically to the gland and ionising radiation detector captures their emissions. The iodine concentration in the Thyroid, as well as the variation of this concentration over time reflects the function of the gland. The RIA is based on the analysis of the values associated with the t3, t4 and tsh hormones, and when these three parameters are in a certain range the patients can be classified. The sample size was calculated in order to estimate the gross coincidence percent between both methods with a precision of 1 % at a confidence level of 95%. In total 110 patients were included in the trial. Mainly two types of statistical analysis were carried out, in the first analysis all the patients included in the study were considered whereas in the second analysis the patients with doubtful RIA results were not included. Ideally the performance of a diagnostic tool is evaluated through the estimation of its sensitivity and specificity. Nevertheless, in the present study the reference procedure (RIA) can not be considered a gold standard diagnostic device. In such a setting the international regulations advise to use measurements of agreement to evaluate the diagnostic capacity of the new method. In the present study we evaluated the level of diagnostic agreement between the DETEC-PC and the RIA using the Kappa statistics. Additionally, the confidence interval for the Kappa statistics and the corresponding significant test for the present of agreement were also computes. The obtained

  13. The value of Standards and Labelling: an international cost-benefit analysis tool for Standards and Labelling programs with results for Central American countries

    International Nuclear Information System (INIS)

    Buskirk, Robert D. Van; McNeil, Michael A.; Letschert, Virginie E.

    2005-01-01

    We describe a cost-benefit spreadsheet analysis tool that provides an evaluation of the net impacts of an appliance standards and labelling (SandL) program. The tool is designed to provide a rough estimate at very low cost to local analysts, while allowing for a more accurate evaluation when detailed local data are available. The methodology takes a bottom-up engineering approach, beginning with appliance-specific engineering parameters relating efficiency improvement and incremental costs associated with specific design technologies. Efficiency improvement afforded by each potential policy option is combined with local appliance use patterns to estimate average annual energy consumption for each appliance. This information is combined with appliance lifetime data and local energy prices to provide a life cycle cost impact assessment at the household level. In addition to household level impacts, the analysis tool forecasts future appliance sales, in order to calculate potential energy savings, consumer financial impacts and carbon emissions reductions at the national level. In order to demonstrate the features of the policy model employed, this poster presents a regional analysis based on the most recent publicly available appliance data. In particular, a set of developing countries in Central America were chosen as an example. Taken as a whole, the Central American results demonstrate the general level of benefit which could be afforded in these countries. Comparison between the countries reveals the key parameters determining the benefit a given country can expect from a standards program

  14. The next organizational challenge: finding and addressing diagnostic error.

    Science.gov (United States)

    Graber, Mark L; Trowbridge, Robert; Myers, Jennifer S; Umscheid, Craig A; Strull, William; Kanter, Michael H

    2014-03-01

    Although health care organizations (HCOs) are intensely focused on improving the safety of health care, efforts to date have almost exclusively targeted treatment-related issues. The literature confirms that the approaches HCOs use to identify adverse medical events are not effective in finding diagnostic errors, so the initial challenge is to identify cases of diagnostic error. WHY HEALTH CARE ORGANIZATIONS NEED TO GET INVOLVED: HCOs are preoccupied with many quality- and safety-related operational and clinical issues, including performance measures. The case for paying attention to diagnostic errors, however, is based on the following four points: (1) diagnostic errors are common and harmful, (2) high-quality health care requires high-quality diagnosis, (3) diagnostic errors are costly, and (4) HCOs are well positioned to lead the way in reducing diagnostic error. FINDING DIAGNOSTIC ERRORS: Current approaches to identifying diagnostic errors, such as occurrence screens, incident reports, autopsy, and peer review, were not designed to detect diagnostic issues (or problems of omission in general) and/or rely on voluntary reporting. The realization that the existing tools are inadequate has spurred efforts to identify novel tools that could be used to discover diagnostic errors or breakdowns in the diagnostic process that are associated with errors. New approaches--Maine Medical Center's case-finding of diagnostic errors by facilitating direct reports from physicians and Kaiser Permanente's electronic health record--based reports that detect process breakdowns in the followup of abnormal findings--are described in case studies. By raising awareness and implementing targeted programs that address diagnostic error, HCOs may begin to play an important role in addressing the problem of diagnostic error.

  15. Green and sustainable remediation (GSR) evaluation: framework, standards, and tool. A case study in Taiwan.

    Science.gov (United States)

    Huang, Wen-Yen; Hung, Weiteng; Vu, Chi Thanh; Chen, Wei-Ting; Lai, Jhih-Wei; Lin, Chitsan

    2016-11-01

    Taiwan has a large number of poorly managed contaminated sites in need of remediation. This study proposes a framework, a set of standards, and a spreadsheet-based evaluation tool for implementing green and sustainable principles into remediation projects and evaluating the projects from this perspective. We performed a case study to understand how the framework would be applied. For the case study, we used a spreadsheet-based evaluation tool (SEFA) and performed field scale cultivation tests on a site contaminated with total petroleum hydrocarbons (TPHs). The site was divided into two lots: one treated by chemical oxidation and the other by bioremediation. We evaluated five core elements of green and sustainable remediation (GSR): energy, air, water resources, materials and wastes, and land and ecosystem. The proposed evaluation tool and field scale cultivation test were found to efficiently assess the effectiveness of the two remediation alternatives. The framework and related tools proposed herein can potentially be used to support decisions about the remediation of contaminated sites taking into account engineering management, cost effectiveness, and social reconciliation.

  16. Adaptation and standardization of a Western tool for assessing child development in non-Western low-income context

    Directory of Open Access Journals (Sweden)

    Teklu Gemechu Abessa

    2016-07-01

    Full Text Available Abstract Background Due to lack of culturally relevant assessment tools, little is known about children’s developmental profiles in low income settings such as Ethiopia. The objective of this study was to adapt and standardize the Denver II for assessing child development in Jimma Zone, South West Ethiopia. Methods Culture-specific test items in Denver II were modified. After translation into two local languages, all test items were piloted and fine-tuned. Using 1597 healthy children 4 days to 70.6 months of age, the 25, 50, 75 and 90 % passing ages were determined for each test item as milestones. Milestones attainment on the adapted version and the Denver II were compared on the 90 % passing age. Reliability of the adapted tool was examined. Results A total of 36 (28.8 % test items, mostly from personal social domain, were adapted. Milestones attainment ages on the two versions differed significantly on 42 (34 % test items. The adapted tool has an excellent inter-rater on 123 (98 % items and substantial to excellent test-retest reliability on 119 (91 % items. Conclusions A Western developmental assessment tool can be adapted reliably for use in low-income settings. Age differences in attaining milestones indicate a correct estimation of child development requires a population-specific standard.

  17. Diagnostic accuracy of the iCare rebound tonometer compared to the Perkins applanation tonometer in assessing intraocular pressure in rural patients.

    Science.gov (United States)

    Li, Yifan; Carpenter, Christopher R; Nicholson, Kathryn; Milne, William Ken

    2015-12-01

    Vision health is recognized as a critical unmet need in North America. The ocular morbidity associated with glaucoma results from increased intraocular pressure (IOP) and early detection is crucial for the management of glaucoma. Our objective was to find a diagnostically accurate screening tool for intraocular hypertension that can be used in rural communities. We sought to validate the diagnostic accuracy of the iCare rebound tonometer against the gold standard Perkins applanation tonometer (PAT) in measuring IOP. Patients from two rural communities in Ontario, Canada visiting their optometrists for routine appointments had their IOP measured by a non-contact tonometer (NCT), an iCare rebound tonometer, and a Perkins applanation tonometer (PAT). Values of sensitivity, specificity, and likelihood ratios for a positive and negative result were calculated for the iCare and the NCT. Complete data was collected from 209 patients. Overall, the iCare tonometer had high levels of validity, as compared to the gold standard PAT. The iCare tonometer displayed excellent sensitivity of 98.3% (90-99%, 95% CI) and excellent negative likelihood ratio of 0.024 (0.0088-0.066, 95% CI) which is useful for ruling out intraocular hypertension. The iCare tonometer is a reasonably valid tool for detecting elevated IOP. Its ease of use, simplicity, and accessibility makes it a good screening tool to improve eye health in rural areas.

  18. Center of excellence in research reporting in neurosurgery--diagnostic ontology.

    Directory of Open Access Journals (Sweden)

    Amrapali Zaveri

    Full Text Available MOTIVATION: Evidence-based medicine (EBM, in the field of neurosurgery, relies on diagnostic studies since Randomized Controlled Trials (RCTs are uncommon. However, diagnostic study reporting is less standardized which increases the difficulty in reliably aggregating results. Although there have been several initiatives to standardize reporting, they have shown to be sub-optimal. Additionally, there is no central repository for storing and retrieving related articles. RESULTS: In our approach we formulate a computational diagnostic ontology containing 91 elements, including classes and sub-classes, which are required to conduct Systematic Reviews-Meta Analysis (SR-MA for diagnostic studies, which will assist in standardized reporting of diagnostic articles. SR-MA are studies that aggregate several studies to come to one conclusion for a particular research question. We also report high percentage of agreement among five observers as a result of the interobserver agreement test that we conducted among them to annotate 13 articles using the diagnostic ontology. Moreover, we extend our existing repository CERR-N to include diagnostic studies. AVAILABILITY: The ontology is available for download as an.owl file at: http://bioportal.bioontology.org/ontologies/3013.

  19. Explanation of diagnostic criteria for radiation-induced nervous system disease

    International Nuclear Information System (INIS)

    Xing Zhiwei; Jiang Enhai

    2012-01-01

    National occupational health standard-Diagnostic Criteria for Radiation-Induced Nervous System Disease has been issued and implemented by the Ministry of health. This standard contained three independent criteria of the brain, spinal cord and peripheral nerve injury. These three kinds of disease often go together in clinic,therefore,the three diagnostic criteria were merged into radioactive nervous system disease diagnostic criteria for entirety and maneuverability of the standard. This standard was formulated based on collection of the clinical practice experience, extensive research of relevant literature and foreign relevant publications. It is mainly applied to diagnosis and treatment of occupational radiation-induced nervous system diseases, and to nervous system diseases caused by medical radiation exposure as well. In order to properly implement this standard, also to correctly deal with radioactive nervous system injury, the main contents of this standard including dose threshold, clinical manifestation, indexing standard and treatment principle were interpreted in this article. (authors)

  20. Use of CAPE-OPEN standards in the interoperability between modelling tools (MoT) and process simulators (ProSim)

    DEFF Research Database (Denmark)

    Morales Rodriguez, Ricardo; Gani, Rafiqul; Déchelotte, Stéphane

    2008-01-01

    Computer-aided design, analysis and/or operation of chemical products and processes that manufacture them require a number of computational tools. As these tools may come from different sources and disciplines, an important issue is how they can be used simultaneously and efficiently for the design...... computational tools according to problem specific work-flows/data-flows. The reliability of the integration of different tools is illustrated through two case studies. In case study 1, the tools Simulis® Thermodynamics (PME) and ICAS-MoT (PMC) are combined for the calculation of thermodynamic properties through......SimPlus-ICAS-MoT-COFE interoperability is also carried out successfully to proof the interoperability of the different computational entities. Furthermore, the introduction of the multiscale modelling concept and its application through the CAPE-OPEN standards is highlighted....

  1. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

    Directory of Open Access Journals (Sweden)

    Wilfredo R Matias

    Full Text Available Rapid diagnostic tests (RDT for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7% were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6% and 71.1% (95%CI: 64.7%-76.9%, respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100% and specificity of 69.1% (95%CI: 55.2%-80.9%. SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8% and specificity of 92.8% (95%CI: 88.4%-95.9%. Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

  2. Development of a non-contact diagnostic tool for high power lasers

    Science.gov (United States)

    Simmons, Jed A.; Guttman, Jeffrey L.; McCauley, John

    2016-03-01

    High power lasers in excess of 1 kW generate enough Rayleigh scatter, even in the NIR, to be detected by silicon based sensor arrays. A lens and camera system in an off-axis position can therefore be used as a non-contact diagnostic tool for high power lasers. Despite the simplicity of the concept, technical challenges have been encountered in the development of an instrument referred to as BeamWatch. These technical challenges include reducing background radiation, achieving high signal to noise ratio, reducing saturation events caused by particulates crossing the beam, correcting images to achieve accurate beam width measurements, creating algorithms for the removal of non-uniformities, and creating two simultaneous views of the beam from orthogonal directions. Background radiation in the image was reduced by the proper positioning of the back plane and the placement of absorbing materials on the internal surfaces of BeamWatch. Maximizing signal to noise ratio, important to the real-time monitoring of focus position, was aided by increasing lens throughput. The number of particulates crossing the beam path was reduced by creating a positive pressure inside BeamWatch. Algorithms in the software removed non-uniformities in the data prior to generating waist width, divergence, BPP, and M2 results. A dual axis version of BeamWatch was developed by the use of mirrors. By its nature BeamWatch produced results similar to scanning slit measurements. Scanning slit data was therefore taken and compared favorably with BeamWatch results.

  3. — study of the use of two standard- and non-standard-measuring devices

    Directory of Open Access Journals (Sweden)

    Paweł Ostapkowicz

    2014-03-01

    Full Text Available This paper deals with leak detection in liquid transmission pipelines. Diagnostic method based on negative pressure wave detection is taken into account here. The paper focuses on variant of this method, related to the use of only two measurement points (devices, placed at the inlet and outlet of the pipeline. Standard transducers for measurement of pressure signals and non-standard elaborated technique for measurement of new diagnostic signals were used. New diagnostic signals, conventionally named the signals of weak interactions, result from the work of special devices (correctors joined to the pipeline. In order to compare both hardware solutions key performance attributes for the analyzed leak detection method were determined. The bases of such assessment were experimental tests. They were conducted with the use of a physical model of a pipeline. The pipeline was 380 meters long, 34 mm in internal diameter and made of polyethylene (PEHD pipes. The medium pumped through the pipeline was water. Carrying out such research, diagnostic procedures elaborated by the author were used and tested.[b]Keywords[/b]: technical diagnostics, pipelines, leak detection

  4. How to appraise a diagnostic test

    Directory of Open Access Journals (Sweden)

    Ramanitharan Manikandan

    2011-01-01

    Full Text Available Urologists frequently encounter problems in making a clinical diagnosis whose resolution requires the use of diagnostic tests. With an ever increasing choice of investigations being available, the urologist often has to decide which diagnostic test(s will best resolve the patient′s diagnostic problem. In this article, we aim to help the urologist understand how to critically appraise studies on diagnostic tests and make a rational choice. This article presents the guiding principles in scientifically assessing studies on diagnostic tests by proposing a clinical scenario. The authors describe a standardized protocol to assess the validity of the test and its relevance to the clinical problem that can help the urologist in decision making. The three important issues to be considered when evaluating the validity of the study are to identify how the study population was chosen, how the test was performed and whether there is a comparison to the gold standard test so as to confirm or refute the diagnosis. Then, the urologist would need to know the probability of the test in providing the correct diagnosis in an individual patient in order to decide about its utility in solving the diagnostic dilemma. By performing the steps described in this article, the urologist would be able to critically appraise diagnostic studies and draw meaningful conclusions about the investigations in terms of validity, results and its applicability to the patient′s problem. This would provide a scientific basis for using diagnostic tests for improving patient care.

  5. Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

    Directory of Open Access Journals (Sweden)

    M. H. Kharita

    2017-06-01

    Full Text Available Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013 to verify compliance of performance of X-ray machines with the regulatory requirements stipulated by the national regulatory body. Materials and Methods: In this study, QC audit included 487 X-ray diagnostic machines, (363 radiography and 124 fluoroscopy devices, installed in 306 medical diagnostic radiology centers in 14 provinces in Syria. We employed an X-ray beam analyzer device (NERO model 8000, Victoreen, USA, which was tested and calibrated at the National Secondary Standard Dosimetry Laboratory traceable to the IAEA Network of Secondary Standard Dosimetry Laboratories. Standard QC tool kits were used to evaluate tube and generator of the X-ray machines, which constituted potential (kVp, timer accuracy, radiation output consistency, tube filtration, small and large focal spot sizes, X-ray beam collimation and alignment, as well as high- and low-resolution and entrance surface dose in fluoroscopy. Results: According to our results, most of the assessed operating parameters were in compliance with the standards stipulated by the National Regulatory Authority. In cases of noncompliance for the assessed parameters, maximum value (28.77% pertained to accuracy of kVp calibration for radiography units, while the lowest value (2.42% belonged to entrance surface dose in fluoroscopy systems. Conclusion: Effective QC program in diagnostic radiology leads to obtaining information regarding quality of radiology devices used for medical diagnosis and minimizing the doses received by patients and medical personnel. The findings of this QC program, as the main part of QA program, illustrated that most

  6. Diagnostic double guarded low-volume uterine lavage in mares

    DEFF Research Database (Denmark)

    Christoffersen, Mette; Brandis, Louise; Samuelsson, Julia

    2014-01-01

    Endometritis constitutes a major problem in the management of broodmares; hence diagnostic tests with a high sensitivity and specificity are desired. We hypothesize that a double guarded uterine flush technique for bacterial culture and cytology is comparable to standard diagnostic tests, the end......Endometritis constitutes a major problem in the management of broodmares; hence diagnostic tests with a high sensitivity and specificity are desired. We hypothesize that a double guarded uterine flush technique for bacterial culture and cytology is comparable to standard diagnostic tests...... (lavage: 11%, swab: 8%, biopsy: 7%) (positive bacterial growth > 4 Colony forming units (CFU)). Positive cytology was less likely to occur when E. coli was isolated from the diagnostic tests compared to the growth of β-hemolytic streptococci. Isolation of pathogens from uterine samples was highly...

  7. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    Science.gov (United States)

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  8. Diagnostic nuclear medicine. 2. rev. ed.

    International Nuclear Information System (INIS)

    Schiepers, C.

    2006-01-01

    The field of nuclear medicine is undergoing rapid expansion, and is evolving into diagnostic molecular imaging. During recent years, dual-modality imaging with PET/CT has gained acceptance and this is currently the fastest-growing technique for oncological imaging applications. The glucose analogue FDG has held its place in diagnostic oncology, assessment of myocardial viability and diagnosis of neuro-degenerative disorders. Peptides have become even more important as imaging agents. The accuracy of hepatobiliary scintigraphy has been enhanced by cholecystokinin. The use of ACE inhibitors in the evaluation of renovascular hypertension has become the standard in renography. New instrumentation has led to faster scanners, and computer development to better image processing software. Automatic processing is more common, and standardization of protocols can be accomplished easily. The field of gene imaging has progressed, although routine clinical applications are not yet available. The present text, supplemented with many detailed and informative illustrations, represents an adjunct to the standard knowledge of diagnostic nuclear medicine and provides both the student and the professional with an overview of developments during the past decade. (orig.)

  9. Nordic working group for medical x-ray diagnostics: Diagnostic reference levels within xray diagnostics - experiences in the Nordic countries

    International Nuclear Information System (INIS)

    Leitz, W.; Groen, P.; Servomaa, A.; Einarsson, G.; Olerud, H.

    2003-01-01

    Medical x-ray diagnostics is one of the few applications of ionising radiation where people are irradiated on purpose. The strategy for radiation protection is also different compared to that in other areas that have the zero-alternative as its ultimate goal, meaning that no human beings at all are exposed in these practices. The focus in x-ray diagnostics concerning radiation protection is justification and optimisation. Optimisation implies that the examination is performed in such a way that the radiation dose is as small as possible without jeopardising the diagnostic security. X- ray diagnostics is a complex method where many technical parameters and methodology factors together are interacting in the determination of radiation dose and image quality. The optimisation process is not a simple and uncomplicated procedure, this difficulty is reflected in many international and national surveys showing a large spread of patient doses for one and the same type of examination. The concept diagnostic reference levels (DRL) has been introduced as a tool for reducing this wide distribution that is obviously indicating a lack of optimisation, and for cutting the highest radiation doses. In this presentation the concept for DRL and the experience gained in the Nordic countries with DRL are described. (orig.)

  10. Ambient diagnostics

    CERN Document Server

    Cai, Yang

    2014-01-01

    Part I. FundamentalsIntroductionWhat is Ambient Diagnostics?Diagnostic ModelsMultimedia IntelligenceCrowd SourcingSoft SensorsScience of SimplicityPersonal DiagnosesBasic AlgorithmsBasic ToolsSummaryProblemsTransformationEarly Discoveries of Heartbeat PatternsTransforms, Features, and AttributesSequential FeaturesSpatiotemporal FeaturesShape FeaturesImagery FeaturesFrequency Domain FeaturesMulti-Resolution FeaturesSummaryProblemsPattern RecognitionSimilarities and DistancesClustering MethodsClassification MethodsClassifier Accuracy MeasuresSummaryProblemsPart II. Multimedia IntelligenceSound RecognitionMicrophone AppsModern Acoustic Transducers (Microphones)Frequency Response CharacteristicsDigital Audio File FormatsHeart Sound SensingLung Sound SensingSnore MeterSpectrogram (STFT)Ambient Sound AnalysisSound RecognitionRecognizing Asthma SoundPeak ShiftFeature CompressionRegroupingNoise IssuesFuture ApplicationsSummaryProblemsColor SensorsColor SensingHuman Color VisionColor SensorsColor Matching ExperimentsC...

  11. Patient dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Shrimpton, P.C.

    2000-01-01

    Full text: X-ray examinations remain an essential and widely used diagnostic tool in medicine and hence the most significant source of exposure to man-made radiation for populations. Patterns of practice in diagnostic radiology continue to evolve, with overall growth in the numbers of procedures worldwide and, particularly in developed countries, increasing importance for complex procedures such as computed tomography (CT) and interventional techniques. In order to maximise the benefits from x-rays relative to the associated radiation risks, there is a need to ensure the prior justification of all examinations and the optimisation of patient protection such that doses are as low as reasonably practicable to meet specific clinical requirements. Accordingly, patient dosimetry is a fundamental requirement in diagnostic radiology. Detailed measurements for the assessment of risks or comparison of different types of procedure require the estimation of organ and effective doses. Such comprehensive dosimetry necessarily involves the simulation of clinical practice using anthropomorphic phantoms, with either measurements in a physical phantom or calculations utilising a mathematical phantom. Simpler measurements for the routine monitoring of dose in x-ray departments can be based on practical quantities such as entrance surface dose, dose-area product and, for CT, weighted CT dose index and dose-length product. Widescale surveys reveal significant variations between departments in the typical doses for a given type of procedure and potential scope for dose reductions. In order to promote improvements in practice, the results of periodic dose surveys in departments should be compared with appropriate standards, such as diagnostic reference levels for adult and paediatric patients, that are set nationally or locally for the purposes of promoting critical review of the equipment and techniques in use. Patient dosimetry should form an essential element of routine quality

  12. Next-generation confirmatory disease diagnostics

    Science.gov (United States)

    Lin, Robert; Gerver, Rachel; Karns, Kelly; Apori, Akwasi A.; Denisin, Aleksandra K.; Herr, Amy E.

    2014-06-01

    Microfluidic tools are advancing capabilities in screening diagnostics for use in near-patient settings. Here, we review three case studies to illustrate the flexibility and analytical power offered by microanalytical tools. We first overview a near-patient tool for detection of protein markers found in cerebrospinal fluid (CSF), as a means to identify the presence of cerebrospinal fluid in nasal mucous - an indication that CSF is leaking into the nasal cavity. Microfluidic design allowed integration of several up-stream preparatory steps and rapid, specific completion of the human CSF protein assay. Second, we overview a tear fluid based assay for lactoferrin, a protein produced in the lacrimal gland, then secreted into tear fluid. Tear Lf is a putative biomarker for primary SS. A critical contribution of this and related work being measurement of Lf, even in light of well-known and significant matrix interactions and losses during the tear fluid collection and preparation. Lastly, we review a microfluidic barcode platform that enables rapid measurement of multiple infectious disease biomarkers in human sera. The assay presents a new approach to multiplexed biomarker detection, yet in a simple straight microchannel - thus providing a streamlined, simplified microanalytical platform, as is relevant to robust operation in diagnostic settings. We view microfluidic design and analytical chemistry as the basis for emerging, sophisticated assays that will advance not just screening diagnostic technology, but confirmatory assays, sample preparation and handling, and thus introduction and utilization of new biomarkers and assay formats.

  13. Reducing beam shaper alignment complexity: diagnostic techniques for alignment and tuning

    Science.gov (United States)

    Lizotte, Todd E.

    2011-10-01

    Safe and efficient optical alignment is a critical requirement for industrial laser systems used in a high volume manufacturing environment. Of specific interest is the development of techniques to align beam shaping optics within a beam line; having the ability to instantly verify by a qualitative means that each element is in its proper position as the beam shaper module is being aligned. There is a need to reduce these types of alignment techniques down to a level where even a newbie to optical alignment will be able to complete the task. Couple this alignment need with the fact that most laser system manufacturers ship their products worldwide and the introduction of a new set of variables including cultural and language barriers, makes this a top priority for manufacturers. Tools and methodologies for alignment of complex optical systems need to be able to cross these barriers to ensure the highest degree of up time and reduce the cost of maintenance on the production floor. Customers worldwide, who purchase production laser equipment, understand that the majority of costs to a manufacturing facility is spent on system maintenance and is typically the largest single controllable expenditure in a production plant. This desire to reduce costs is driving the trend these days towards predictive and proactive, not reactive maintenance of laser based optical beam delivery systems [10]. With proper diagnostic tools, laser system developers can develop proactive approaches to reduce system down time, safe guard operational performance and reduce premature or catastrophic optics failures. Obviously analytical data will provide quantifiable performance standards which are more precise than qualitative standards, but each have a role in determining overall optical system performance [10]. This paper will discuss the use of film and fluorescent mirror devices as diagnostic tools for beam shaper module alignment off line or in-situ. The paper will also provide an overview

  14. Implementation of TMA and digitalization in routine diagnostics of breast pathology.

    Science.gov (United States)

    Rossing, Henrik Holm; Talman, Maj-Lis Møller; Laenkholm, Anne-Vibeke; Wielenga, Vera Timmermans

    2012-04-01

    To ensure optimal treatment of breast cancer patients, breast tumours are classified based on clinico-pathological features. As part of this process, routine diagnostics of breast tumours includes histological typing and grading, as well as profiling by use of an immunohistochemistry panel of antibodies, probes and in situ hybridization. This will, as a minimum, include assessment of oestrogen receptor (OR) and HER2. The individual preparation and staining of many breast tumours in a large laboratory with this standard panel is thus time consuming and costly. Herein, we show that in breast cancer routine diagnostics the use of the tissue microarray technique in combination with digitalization of the stained multi-slides is not only economical, with a considerable cost reduction, but it also enhances standardization of tumour profiling. We demonstrate that 2 mm breast tumour cores correlate with the corresponding tumour on whole mount slides, regarding staining/hybridizing results with the biomarkers in our panel consisting of human epidermal growth factor receptor 2, OR and Topiomerase IIa. Furthermore, we show that simultaneous staining/hybridizing of multiple breast tumour specimens reduces variation of staining/hybridizing quality, hereby increasing reliability of interpretation. By scanning and digitalization of the stained and hybridized multi-slides, we could optimize documentation and filing of the results. Our work is an example of translational research by implementing a tool in daily diagnostics originally developed for high throughput analyses in the search for prognostic and predictive markers in targeted medicine. © 2012 The Authors APMIS © 2012 APMIS.

  15. Pinpointing water entries using pulsed neutron and Production logging tools

    International Nuclear Information System (INIS)

    Mukerji, P.; Oluwa, J.

    2003-01-01

    A successful work over requires a comprehensive understanding of fluid entries into the wellbore and fluid contact movement in the reservoir. Such information can be obtained by a combination of production logs and saturation-monitoring measurements. The ability to combine pulsed neutron and production logging tools provides the operator with better diagnostics for identifying candidates for remedial actions and greatly increases the possibility of a successful well intervention. Advances in pulsed neutron spectroscopy tools have improved the accuracy and precision of measured carbon/oxygen ratios. Some of the improvements in accuracy and precision have resulted from better tool characterization in a wider variety of logging environments in the calibration facility and new spectral standards. Coincident with the advances in pulsed neutron spectroscopy has been the development of production logging measurements run on a platform common. We will show how the application of pulsed neutron and production logs can optimize subsequent well intervention to reduce water production and/or increase oil production

  16. Identification of facilitators and barriers to residents' use of a clinical reasoning tool.

    Science.gov (United States)

    DiNardo, Deborah; Tilstra, Sarah; McNeil, Melissa; Follansbee, William; Zimmer, Shanta; Farris, Coreen; Barnato, Amber E

    2018-03-28

    While there is some experimental evidence to support the use of cognitive forcing strategies to reduce diagnostic error in residents, the potential usability of such strategies in the clinical setting has not been explored. We sought to test the effect of a clinical reasoning tool on diagnostic accuracy and to obtain feedback on its usability and acceptability. We conducted a randomized behavioral experiment testing the effect of this tool on diagnostic accuracy on written cases among post-graduate 3 (PGY-3) residents at a single internal medical residency program in 2014. Residents completed written clinical cases in a proctored setting with and without prompts to use the tool. The tool encouraged reflection on concordant and discordant aspects of each case. We used random effects regression to assess the effect of the tool on diagnostic accuracy of the independent case sets, controlling for case complexity. We then conducted audiotaped structured focus group debriefing sessions and reviewed the tapes for facilitators and barriers to use of the tool. Of 51 eligible PGY-3 residents, 34 (67%) participated in the study. The average diagnostic accuracy increased from 52% to 60% with the tool, a difference that just met the test for statistical significance in adjusted analyses (p=0.05). Residents reported that the tool was generally acceptable and understandable but did not recognize its utility for use with simple cases, suggesting the presence of overconfidence bias. A clinical reasoning tool improved residents' diagnostic accuracy on written cases. Overconfidence bias is a potential barrier to its use in the clinical setting.

  17. Analytical and diagnostic performance of a qPCR assay for Ichthyophonus spp. compared to the tissue culture 'gold standard'.

    Science.gov (United States)

    Lowe, Vanessa C; Hershberger, Paul K; Friedman, Carolyn S

    2018-06-04

    Parasites of the genus Ichthyophonus infect many fish species and have a non-uniform distribution within host tissues. Due in part to this uneven distribution, the comparative sensitivity and accuracy of using molecular-based detection methods versus culture to estimate parasite prevalence is under debate. We evaluated the analytical and diagnostic performance of an existing qPCR assay in comparison to the 'gold standard' culture method using Pacific herring Clupea pallasii with known exposure history. We determined that the assay is suitable for use in this host, and diagnostic specificity was consistently high (>98%) in both heart and liver tissues. Diagnostic sensitivity could not be fully assessed due to low infection rates, but our results suggest that qPCR is not as sensitive as culture under all circumstances. Diagnostic sensitivity of qPCR relative to culture is likely affected by the amount of sample processed. The prevalence values estimated by the 2 methods were not significantly different when sample amounts were equal (heart tissue), but when the assayed sample amounts were unequal (liver tissue), the culture method detected a significantly higher prevalence of the parasite than qPCR. Further, culture of liver also detected significantly more Ichthyophonus infections than culture of heart, suggesting that the density and distribution of parasites in tissues also plays a role in assay sensitivity. This sensitivity issue would be most problematic for fish with light infections. Although qPCR does not detect the presence of a live organism, DNA-based pathogen detection methods provide the opportunity for alternate testing strategies when culture is not possible.

  18. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    International Nuclear Information System (INIS)

    Chon, Kwon Su; Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha

    2009-01-01

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-μm thickness. With a thicker molybdenum filter (100 μm thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-μm thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue

  19. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Chon, Kwon Su [Catholic University of Daegu, Daegu (Korea, Republic of); Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha [Wonkwang University, Iksan (Korea, Republic of)

    2009-12-15

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-{mu}m thickness. With a thicker molybdenum filter (100 {mu}m thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-{mu}m thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue.

  20. User interface graphically improves generator AL diagnostics

    International Nuclear Information System (INIS)

    Gray, R.F.; King, I.J.

    1991-01-01

    In April of 1990, the recently developed Diagnostic Graphical User Interface (DGUI) was installed at a large nuclear power plant in the midwestern United States. Since 1988, the power plant has been using the Generator Artificial Intelligence Diagnostics (GenAID) System, which provides online diagnostic capability for the generator and generator auxiliaries through a plant data center (PDC) and communication link to the diagnostic operations center (DOC) in Orlando, Florida. The enhanced system provides the power plant control room operator with a comprehensive tool to understand and better utilize the information provided by the existing knowledge bases. This paper represents a significant improvement over existing technology by providing the power plant control room operator with the capability of interacting directly with the diagnostic system

  1. Extended Testability Analysis Tool

    Science.gov (United States)

    Melcher, Kevin; Maul, William A.; Fulton, Christopher

    2012-01-01

    The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.

  2. Quality of reporting of diagnostic accuracy studies

    NARCIS (Netherlands)

    Smidt, N.; Rutjes, A.W.; Windt - Mens, van der D.A.W.M.; Ostelo, R.W.J.G.; Reitsma, J.B.; Bouter, L.M.; Vet, de H.C.W.

    2005-01-01

    PURPOSE: To evaluate quality of reporting in diagnostic accuracy articles published in 2000 in journals with impact factor of at least 4 by using items of Standards for Reporting of Diagnostic Accuracy (STARD) statement published later in 2003. MATERIALS AND METHODS: English-language articles on

  3. ADHD and Present Hedonism: time perspective as a potential diagnostic and therapeutic tool

    Directory of Open Access Journals (Sweden)

    Weissenberger S

    2016-11-01

    Full Text Available S Weissenberger,1 M Klicperova-Baker,2 P Zimbardo,3 K Schonova,1 D Akotia,1 J Kostal,2 M Goetz,4 J Raboch,1 R Ptacek1 1First Medical Faculty, Charles University, 2Institute of Psychology, Academy of Sciences of the Czech Republic, Praha, Czech Republic; 3Department of Psychology, Stanford University, Stanford, CA, USA; 4Second Faculty of Medicine, Department of Child Psychiatry, Charles University, Motol University Hospital, Praha, Czech RepublicAbstract: The article draws primarily from the behavioral findings (mainly psychiatric and psychological observations and points out the important relationships between attention-deficit/hyperactivity disorder (ADHD symptoms and time orientation. Specifically, the authors argue that there is a significant overlap between the symptoms of ADHD and Present Hedonism. Present Hedonism is defined by Zimbardo’s time perspective theory and assessed by Zimbardo Time Perspective Inventory. Developmental data on Present Hedonism of males and females in the Czech population sample (N=2201 are also presented. The hypothesis of relationship between ADHD and Present Hedonism is mainly derived from the prevalence of addictive behavior (mainly excessive Internet use, alcohol abuse, craving for sweets, fatty foods, and fast foods, deficits in social learning, and increased aggressiveness both in ADHD and in the population high on Present Hedonism. We conclude that Zimbardo’s time perspective offers both: 1 a potential diagnostic tool – the Zimbardo Time Perspective Inventory, particularly its Present Hedonism scale, and 2 a promising preventive and/or therapeutic approach by the Time Perspective Therapy. Time Perspective Therapy has so far been used mainly to treat past negative trauma (most notably, posttraumatic stress disorder; however, it also has value as a potential therapeutic tool for possible behavioral compensation of ADHD.Keywords: ADHD, time perspective, ZTPI, Zimbardo, addiction, alcoholism, delinquency

  4. Leishmania OligoC-TesT as a simple, rapid, and standardized tool for molecular diagnosis of cutaneous leishmaniasis in Peru.

    Science.gov (United States)

    Espinosa, Diego; Boggild, Andrea K; Deborggraeve, Stijn; Laurent, Thierry; Valencia, Cristian; Pacheco, Rosa; Miranda-Verástegui, César; Llanos-Cuentas, Alejandro; Leclipteux, Thierry; Dujardin, Jean-Claude; Büscher, Philippe; Arévalo, Jorge

    2009-08-01

    Molecular methods such as PCR have become attractive tools for diagnosis of cutaneous leishmaniasis (CL), both for their high sensitivity and for their specificity. However, their practical use in routine diagnosis is limited due to the infrastructural requirements and the lack of any standardization. Recently, a simplified and standardized PCR format for molecular detection of Leishmania was developed. The Leishmania OligoC-TesT is based on simple and rapid detection using a dipstick with PCR-amplified Leishmania DNA. In this study, we estimated the diagnostic accuracy of the Leishmania OligoC-TesT for 61 specimens from 44 CL-suspected patients presenting at the leishmaniasis clinic of the Instituto de Medicina Tropical Alexander von Humboldt, Peru. On the basis of parasitological detection and the leishmanin skin test (LST), patients were classified as (i) confirmed CL cases, (ii) LST-positive cases, and (iii) LST-negative cases. The sensitivities of the Leishmania OligoC-TesT was 74% (95% confidence interval (CI), 60.5% to 84.1%) for lesion aspirates and 92% (95% CI, 81.2% to 96.9%) for scrapings. A significantly higher sensitivity was observed with a conventional PCR targeting the kinetoplast DNA on the aspirates (94%) (P = 0.001), while there was no significant difference in sensitivity for the lesion scrapings (88%) (P = 0.317). In addition, the Leishmania OligoC-TesT was evaluated for 13 CL-suspected patients in two different peripheral health centers in the central jungle of Peru. Our findings clearly indicate the high accuracy of the Leishmania OligoC-TesT for lesion scrapings for simple and rapid molecular diagnosis of CL in Peru.

  5. Leishmania OligoC-TesT as a Simple, Rapid, and Standardized Tool for Molecular Diagnosis of Cutaneous Leishmaniasis in Peru▿

    Science.gov (United States)

    Espinosa, Diego; Boggild, Andrea K.; Deborggraeve, Stijn; Laurent, Thierry; Valencia, Cristian; Pacheco, Rosa; Miranda-Verástegui, César; Llanos-Cuentas, Alejandro; Leclipteux, Thierry; Dujardin, Jean-Claude; Büscher, Philippe; Arévalo, Jorge

    2009-01-01

    Molecular methods such as PCR have become attractive tools for diagnosis of cutaneous leishmaniasis (CL), both for their high sensitivity and for their specificity. However, their practical use in routine diagnosis is limited due to the infrastructural requirements and the lack of any standardization. Recently, a simplified and standardized PCR format for molecular detection of Leishmania was developed. The Leishmania OligoC-TesT is based on simple and rapid detection using a dipstick with PCR-amplified Leishmania DNA. In this study, we estimated the diagnostic accuracy of the Leishmania OligoC-TesT for 61 specimens from 44 CL-suspected patients presenting at the leishmaniasis clinic of the Instituto de Medicina Tropical Alexander von Humboldt, Peru. On the basis of parasitological detection and the leishmanin skin test (LST), patients were classified as (i) confirmed CL cases, (ii) LST-positive cases, and (iii) LST-negative cases. The sensitivities of the Leishmania OligoC-TesT was 74% (95% confidence interval (CI), 60.5% to 84.1%) for lesion aspirates and 92% (95% CI, 81.2% to 96.9%) for scrapings. A significantly higher sensitivity was observed with a conventional PCR targeting the kinetoplast DNA on the aspirates (94%) (P = 0.001), while there was no significant difference in sensitivity for the lesion scrapings (88%) (P = 0.317). In addition, the Leishmania OligoC-TesT was evaluated for 13 CL-suspected patients in two different peripheral health centers in the central jungle of Peru. Our findings clearly indicate the high accuracy of the Leishmania OligoC-TesT for lesion scrapings for simple and rapid molecular diagnosis of CL in Peru. PMID:19553579

  6. Magnetic resonance imaging-a diagnostic tool for postoperative evaluation of dental implants: a case report.

    Science.gov (United States)

    Wanner, Laura; Ludwig, Ute; Hövener, Jan-Bernd; Nelson, Katja; Flügge, Tabea

    2018-04-01

    Compared with cone beam computed tomography (CBCT), magnetic resonance imaging (MRI) might be superior for the diagnosis of nerve lesions associated with implant placement. A patient presented with unilateral pain associated with dysesthesia in the region of the right lower lip and chin after implant placement. Conventional orthopantomography could not identify an association between the position of the inferior alveolar nerve and the implant. For 3-dimensional display of the implant in relation to the surrounding anatomy, CBCT was compared with MRI. MRI enabled the precise depiction of the implant position and its spatial relation to the inferior alveolar nerve, whereas the nerve position and its exact course within the mandible could not be directly displayed in CBCT. MRI may be a valuable, radiation-free diagnostic tool for the visualization of intraoral hard and soft tissues, offering an objective assessment of nerve injuries by a direct visualization of the inferior alveolar neurovascular bundle. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Applying standards to ICT models, tools and data in Europe to improve river basin networks and spread innovation on water sector

    Science.gov (United States)

    Pesquer, Lluís; Jirka, Simon; van de Giesen, Nick; Masó, Joan; Stasch, Christoph; Van Nooyen, Ronald; Prat, Ester; Pons, Xavier

    2015-04-01

    This work describes the strategy of the European Horizon 2020 project WaterInnEU. Its vision is to enhance the exploitation of EU funded ICT models, tools, protocols and policy briefs related to the water sector and to establish suitable conditions for new market opportunities based on these offerings. The main goals are: • Connect the research results and developments of previous EU funded activities with the already existing data available on European level and also with to the companies that are able to offer products and services based on these tools and data. • Offer an independent marketplace platform complemented by technical and commercial expertise as a service for users to allow the access to products and services best fitting their priorities, capabilities and procurement processes. One of the pillars of WaterInnEU is to stimulate and prioritize the application of international standards into ICT tools and policy briefs. The standardization of formats, services and processes will allow for a harmonized water management between different sectors, fragmented areas and scales (local, regional or international) approaches. Several levels of interoperability will be addressed: • Syntactic: Connecting system and tools together: Syntactic interoperability allows for client and service tools to automatically discover, access, and process data and information (query and exchange parts of a database) and to connect each other in process chains. The discovery of water related data is achieved using metadata cataloguing standards and, in particular, the one adopted by the INSPIRE directive: OGC Catalogue Service for the Web (CSW). • Semantic: Sharing a pan-European conceptual framework This is the ability of computer systems to exchange data with unambiguous, shared meaning. The project therefore addresses not only the packaging of data (syntax), but also the simultaneous transmission of the meaning with the data (semantics). This is accomplished by linking

  8. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    Energy Technology Data Exchange (ETDEWEB)

    Sundstroem, Torbjoern; Riklund, Katrine Aa. [Umeaa University, Umeaa University Hospital, Department of Radiation Sciences, Diagnostic Radiology, Umeaa (Sweden); Elgh, Eva; Naesman, Birgitta [Umeaa University, Department of Community Medicine and Rehabilitation, Geriatric Medicine, Umeaa (Sweden); Larsson, Anne [Umeaa University, Department of Radiation Sciences, Radiation Physics, Umeaa (Sweden); Nyberg, Lars [Umeaa University, Department of Psychology, Umeaa (Sweden)

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2{+-}4.8 years) with mild AD and 18 healthy elderly (69.4{+-}3.9 years) were included in the study. The subjects were injected with{sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF{sup 99m}Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  9. Democratizing molecular diagnostics for the developing world.

    Science.gov (United States)

    Abou Tayoun, Ahmad N; Burchard, Paul R; Malik, Imran; Scherer, Axel; Tsongalis, Gregory J

    2014-01-01

    Infectious diseases that are largely treatable continue to pose a tremendous burden on the developing world despite the availability of highly potent drugs. The high mortality and morbidity rates of these diseases are largely due to a lack of affordable diagnostics that are accessible to resource-limited areas and that can deliver high-quality results. In fact, modified molecular diagnostics for infectious diseases were rated as the top biotechnology to improve health in developing countries. In this review, we describe the characteristics of accessible molecular diagnostic tools and discuss the challenges associated with implementing such tools at low infrastructure sites. We highlight our experience as part of the "Grand Challenge" project supported by the Gates Foundation for addressing global health inequities and describe issues and solutions associated with developing adequate technologies or molecular assays needed for broad access in the developing world. We believe that sharing this knowledge will facilitate the development of new molecular technologies that are extremely valuable for improving global health.

  10. Implementation of an Evidence-Based and Content Validated Standardized Ostomy Algorithm Tool in Home Care: A Quality Improvement Project.

    Science.gov (United States)

    Bare, Kimberly; Drain, Jerri; Timko-Progar, Monica; Stallings, Bobbie; Smith, Kimberly; Ward, Naomi; Wright, Sandra

    Many nurses have limited experience with ostomy management. We sought to provide a standardized approach to ostomy education and management to support nurses in early identification of stomal and peristomal complications, pouching problems, and provide standardized solutions for managing ostomy care in general while improving utilization of formulary products. This article describes development and testing of an ostomy algorithm tool.

  11. Diagnosis of cattle diseases endemic to sub-Saharan Africa: evaluating a low cost decision support tool in use by veterinary personnel.

    Directory of Open Access Journals (Sweden)

    Mark C Eisler

    Full Text Available BACKGROUND: Diagnosis is key to control and prevention of livestock diseases. In areas of sub-Saharan Africa where private practitioners rarely replace Government veterinary services reduced in effectiveness by structural adjustment programmes, those who remain lack resources for diagnosis and might benefit from decision support. METHODOLOGY/PRINCIPAL FINDINGS: We evaluated whether a low-cost diagnostic decision support tool would lead to changes in clinical diagnostic practice by fifteen veterinary and animal health officers undertaking primary animal healthcare in Uganda. The eight diseases covered by the tool included 98% of all bovine diagnoses made before or after its introduction. It may therefore inform proportional morbidity in the area; breed, age and geographic location effects were consistent with current epidemiological understanding. Trypanosomosis, theileriosis, anaplasmosis, and parasitic gastroenteritis were the most common conditions among 713 bovine clinical cases diagnosed prior to introduction of the tool. Thereafter, in 747 bovine clinical cases estimated proportional morbidity of fasciolosis doubled, while theileriosis and parasitic gastroenteritis were diagnosed less commonly and the average number of clinical signs increased from 3.5 to 4.9 per case, with 28% of cases reporting six or more signs compared to 3% beforehand. Anaemia/pallor, weakness and staring coat contributed most to this increase, approximately doubling in number and were recorded in over half of all cases. Finally, although lack of a gold standard hindered objective assessment of whether the tool improved the reliability of diagnosis, informative concordance and misclassification matrices yielded useful insights into its role in the diagnostic process. CONCLUSIONS/SIGNIFICANCE: The diagnostic decision support tool covered the majority of diagnoses made before or after its introduction, leading to a significant increase in the number of clinical signs

  12. Large biases in regression-based constituent flux estimates: causes and diagnostic tools

    Science.gov (United States)

    Hirsch, Robert M.

    2014-01-01

    It has been documented in the literature that, in some cases, widely used regression-based models can produce severely biased estimates of long-term mean river fluxes of various constituents. These models, estimated using sample values of concentration, discharge, and date, are used to compute estimated fluxes for a multiyear period at a daily time step. This study compares results of the LOADEST seven-parameter model, LOADEST five-parameter model, and the Weighted Regressions on Time, Discharge, and Season (WRTDS) model using subsampling of six very large datasets to better understand this bias problem. This analysis considers sample datasets for dissolved nitrate and total phosphorus. The results show that LOADEST-7 and LOADEST-5, although they often produce very nearly unbiased results, can produce highly biased results. This study identifies three conditions that can give rise to these severe biases: (1) lack of fit of the log of concentration vs. log discharge relationship, (2) substantial differences in the shape of this relationship across seasons, and (3) severely heteroscedastic residuals. The WRTDS model is more resistant to the bias problem than the LOADEST models but is not immune to them. Understanding the causes of the bias problem is crucial to selecting an appropriate method for flux computations. Diagnostic tools for identifying the potential for bias problems are introduced, and strategies for resolving bias problems are described.

  13. Artificial neural networks for processing fluorescence spectroscopy data in skin cancer diagnostics

    International Nuclear Information System (INIS)

    Lenhardt, L; Zeković, I; Dramićanin, T; Dramićanin, M D

    2013-01-01

    Over the years various optical spectroscopic techniques have been widely used as diagnostic tools in the discrimination of many types of malignant diseases. Recently, synchronous fluorescent spectroscopy (SFS) coupled with chemometrics has been applied in cancer diagnostics. The SFS method involves simultaneous scanning of both emission and excitation wavelengths while keeping the interval of wavelengths (constant-wavelength mode) or frequencies (constant-energy mode) between them constant. This method is fast, relatively inexpensive, sensitive and non-invasive. Total synchronous fluorescence spectra of normal skin, nevus and melanoma samples were used as input for training of artificial neural networks. Two different types of artificial neural networks were trained, the self-organizing map and the feed-forward neural network. Histopathology results of investigated skin samples were used as the gold standard for network output. Based on the obtained classification success rate of neural networks, we concluded that both networks provided high sensitivity with classification errors between 2 and 4%. (paper)

  14. Diagnosis and Management of Patients with Paroxysmal Sympathetic Hyperactivity following Acute Brain Injuries Using a Consensus-Based Diagnostic Tool: A Single Institutional Case Series.

    Science.gov (United States)

    Godo, Shigeo; Irino, Shigemi; Nakagawa, Atsuhiro; Kawazoe, Yu; Fujita, Motoo; Kudo, Daisuke; Nomura, Ryosuke; Shimokawa, Hiroaki; Kushimoto, Shigeki

    2017-09-01

    Paroxysmal sympathetic hyperactivity (PSH) is a distinct syndrome of episodic sympathetic hyperactivities following severe acquired brain injury, characterized by paroxysmal transient fever, tachycardia, hypertension, tachypnea, excessive diaphoresis and specific posturing. PSH remains to be an under-recognized condition with a diagnostic pitfall especially in the intensive care unit (ICU) settings due to the high prevalence of concomitant diseases that mimic PSH. A consensus set of diagnostic criteria named PSH-Assessment Measure (PSH-AM) has been developed recently, which is consisted of two components: a diagnosis likelihood tool derived from clinical characteristics of PSH, and a clinical feature scale assigned to the severity of each sympathetic hyperactivity. We herein present a case series of patients with PSH who were diagnosed and followed by using PSH-AM in our tertiary institutional medical and surgical ICU between April 2015 and March 2017 in order to evaluate the clinical efficacy of PSH-AM. Among 394 survivors of 521 patients admitted with acquired brain injury defined as acute brain injury at all levels of severity regardless of the presence of altered consciousness, including traumatic brain injury, stroke, infectious disease, and encephalopathy, 6 patients (1.5%) were diagnosed as PSH by using PSH-AM. PSH-AM served as a useful scoring system for early objective diagnosis, assessment of severity, and serial evaluation of treatment efficacy in the management of PSH in the ICU settings. In conclusion, critical care clinicians should consider the possibility of PSH and can use PSH-AM as a useful diagnostic and guiding tool in the management of PSH.

  15. 18F-DOPA PET/CT and 68Ga-DOTANOC PET/CT scans as diagnostic tools in focal congenital hyperinsulinism: a blinded evaluation.

    Science.gov (United States)

    Christiansen, Charlotte Dahl; Petersen, Henrik; Nielsen, Anne Lerberg; Detlefsen, Sönke; Brusgaard, Klaus; Rasmussen, Lars; Melikyan, Maria; Ekström, Klas; Globa, Evgenia; Rasmussen, Annett Helleskov; Hovendal, Claus; Christesen, Henrik Thybo

    2018-02-01

    Focal congenital hyperinsulinism (CHI) is curable by surgery, which is why identification of the focal lesion is crucial. We aimed to determine the use of 18F-fluoro-dihydroxyphenylalanine (18F-DOPA) PET/CT vs. 68Ga-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic-acid-1-Nal3-octreotide (68Ga-DOTANOC) PET/CT as diagnostic tools in focal CHI. PET/CT scans of children with CHI admitted to Odense University Hospital between August 2005 and June 2016 were retrospectively evaluated visually and by their maximal standardized uptake values (SUV max ) by two independent examiners, blinded for clinical, surgical and pathological data. Pancreatic histology was used as the gold standard. For patients without surgery, the genetic profile served as the gold standard. Fifty-five CHI patients were examined by PET/CT (18F-DOPA n = 53, 68Ga-DOTANOC n = 18). Surgery was performed in 34 patients, no surgery in 21 patients. Fifty-one patients had a classifiable outcome, either by histology (n = 33, 22 focal lesions, 11 non-focal) or by genetics (n = 18, all non-focal). The predictive performance of 18F-DOPA PET/CT to identify focal CHI was identical by visual- and cut-off-based evaluation: sensitivity (95% CI) of 1 (0.85-1); specificity of 0.96 (0.82-0.99). The optimal 18F-DOPA PET SUV max ratio cut-off was 1.44 and the optimal 68Ga-DOTANOC PET SUV max cut-off was 6.77 g/ml. The area under the receiver operating curve was 0.98 (0.93-1) for 18F-DOPA PET vs. 0.71 (0.43-0.95) for 68Ga-DOTANOC PET (p PET/CT and 68Ga-DOTANOC PET/CT, respectively. 18F-DOPA PET/CT was excellent in predicting focal CHI and superior compared to 68Ga-DOTANOC PET/CT. Further use of 68GA-DOTANOC PET/CT in predicting focal CHI is discouraged.

  16. Dosimetry in Diagnostic Radiology for Paediatric Patients

    International Nuclear Information System (INIS)

    2013-01-01

    Concern about the radiation dose to children from diagnostic radiology examinations has recently been popularly expressed, particularly as related to computed tomography (CT) procedures. This involves the observation that children can receive doses far in excess of those delivered to adults, in part due to the digital nature of the image receptors that may give no warning to the operator of the dose to the patient. Concern for CT examinations should be extended to the broad range of paediatric diagnostic radiological procedures responsible for radiation doses in children, especially as factors, such as increased radiosensitivity and the longer life expectancy of children, increase the associated radiation risk. In all cases, owing to the added paediatric radiological examination factor of patient size and its associated impact on equipment selection, clinical examination protocol and dosimetric audit, the determination of paediatric dose requires a distinct approach from adult dosimetry associated with diagnostic radiological examinations. In response to this, there is a need to inform health professionals about standardized methodologies used to determine paediatric dose for all major modalities such as general radiography, fluoroscopy and CT. Methodologies for standardizing the conduct of dose audits and their use for the derivation and application of diagnostic reference levels for patient populations, that vary in size, are also required. In addition, a review is needed of the current knowledge on risks specific to non-adults from radiation, and also an analysis of the management of factors contributing to dose from paediatric radiological examinations. In 2007, the IAEA published a code of practice, Dosimetry in Diagnostic Radiology: An International Code of Practice, as Technical Reports Series No. 457 (TRS 457). TRS 457 recommends procedures for dosimetric measurement and calibration for the attainment of standardized dosimetry, and addresses requirements

  17. Molecular diagnostic PCR handbook

    International Nuclear Information System (INIS)

    Viljoen, G.J.; Crowther, J.R.; Nel, L.H.

    2005-01-01

    The uses of nucleic acid-directed methods have increased significantly in the past five years and have made important contributions to disease control country programmes for improving national and international trade. These developments include the more routine use of PCR as a diagnostic tool in veterinary diagnostic laboratories. However, there are many problems associated with the transfer and particularly, the application of this technology. These include lack of consideration of: the establishment of quality-assured procedures, the required set-up of the laboratory and the proper training of staff. This can lead to a situation where results are not assured. This book gives a comprehensive account of the practical aspects of PCR and strong consideration is given to ensure its optimal use in a laboratory environment. This includes the setting-up of a PCR laboratory; Good Laboratory Practice and standardised PCR protocols to detect animal disease pathogens. Examples of Standard Operating Procedures as used in individual specialist laboratories and an outline of training materials necessary for PCR technology transfer are presented. The difficulties, advantages and disadvantages in PCR applications are explained and placed in context with other test systems. Emphasis is placed on the use of PCR for detection of pathogens, with a particular focus on diagnosticians and scientists from the developing world. It is hoped that this book will enable readers from various disciplines and levels of expertise to better judge the merits of PCR and to increase their skills and knowledge in order to assist in a more logical, efficient and assured use of this technology

  18. Comparison of Diagnostic Performance of Semi-Quantitative Knee Ultrasound and Knee Radiography with MRI: Oulu Knee Osteoarthritis Study

    Science.gov (United States)

    Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W.; Arokoski, Jari P.; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T.; Tervonen, Osmo; Koski, Juhani M.; Saarakkala, Simo

    2016-01-01

    Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level. PMID:26926836

  19. Quality Assessment of Research Articles in Nuclear Medicine Using STARD and QUADAS-2 Tools

    International Nuclear Information System (INIS)

    Roysri, Krisana; Chotipanich, Chanisa; Laopaiboon, Vallop; Khiewyoo, Jiraporn

    2014-01-01

    Diagnostic nuclear medicine is being increasingly employed in clinical practice with the advent of new technologies and radiopharmaceuticals. The report of the prevalence of a certain disease is important for assessing the quality of that article. Therefore, this study was performed to evaluate the quality of published nuclear medicine articles and determine the frequency of reporting the prevalence of studied diseases. We used Standards for Reporting of Diagnostic Accuracy (STARD) and Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklists for evaluating the quality of articles published in five nuclear medicine journals with the highest impact factors in 2012. The articles were retrieved from Scopus database and were selected and assessed independently by two nuclear medicine physicians. Decision concerning equivocal data was made by consensus between the reviewers. The average STARD score was approximately 17 points, and the highest score was 17.19±2.38 obtained by the European Journal of Nuclear Medicine. QUADAS-2 tool showed that all journals had low bias regarding study population. The Journal of Nuclear Medicine had the highest score in terms of index test, reference standard, and time interval. Lack of clarity regarding the index test, reference standard, and time interval was frequently observed in all journals including Clinical Nuclear Medicine, in which 64% of the studies were unclear regarding the index test. Journal of Nuclear Cardiology had the highest number of articles with appropriate reference standard (83.3%), though it had the lowest frequency of reporting disease prevalence (zero reports). All five journals had the same STARD score, while index test, reference standard, and time interval were very unclear according to QUADAS-2 tool. Unfortunately, data were too limited to determine which journal had the lowest risk of bias. In fact, it is the author's responsibility to provide details of research methodology so that the

  20. Nuclear/Nucleolar morphometry and DNA image cytometry as a combined diagnostic tool in pathology of prostatic carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kavantzas, N.; Agapitos, E.; Lazaris, A. C.; Pavlopulos, P.M.; Sofikitis, N.; Davaris, P. [National University of Athens, Dept. of Pathology, Medical School, Athens (Greece)

    2001-12-01

    Paraffin tissue sections from 50 patients with prostate adenocarcinoma were used to study nuclear and nucleolar morphometric features by image analysis. The results were compared to DNA ploidy and Gleason grade. In the examined histological samples nuclear and nucleolar areas were positively interrelated. It was also noticed that the higher the percentage of nucleolated nuclei, the bigger the nuclear and nucleolar areas. The morphometric characteristics did not differ significantly among the four grades of the examined specimens. In well-differentiated carcinomas the DNA index was lower than in the rest at a statistically significant level. Hypodiploid carcinomas were found to possess significantly bigger nuclear areas than any other DNA index group. Morphonuclear evidence of anaplasia and DNA aneuploidy may be used as diagnostic tools in prostate cancer in addition to Gleason grade.

  1. Nuclear/Nucleolar morphometry and DNA image cytometry as a combined diagnostic tool in pathology of prostatic carcinoma

    International Nuclear Information System (INIS)

    Kavantzas, N.; Agapitos, E.; Lazaris, A. C.; Pavlopulos, P.M.; Sofikitis, N.; Davaris, P.

    2001-01-01

    Paraffin tissue sections from 50 patients with prostate adenocarcinoma were used to study nuclear and nucleolar morphometric features by image analysis. The results were compared to DNA ploidy and Gleason grade. In the examined histological samples nuclear and nucleolar areas were positively interrelated. It was also noticed that the higher the percentage of nucleolated nuclei, the bigger the nuclear and nucleolar areas. The morphometric characteristics did not differ significantly among the four grades of the examined specimens. In well-differentiated carcinomas the DNA index was lower than in the rest at a statistically significant level. Hypodiploid carcinomas were found to possess significantly bigger nuclear areas than any other DNA index group. Morphonuclear evidence of anaplasia and DNA aneuploidy may be used as diagnostic tools in prostate cancer in addition to Gleason grade

  2. IMPROVEMENT OF METHODS FOR HYDROBIOLOGICAL RESEARCH AND MODIFICATION OF STANDARD TOOLS FOR SAMPLE COLLECTION

    Directory of Open Access Journals (Sweden)

    M. M. Aligadjiev

    2015-01-01

    Full Text Available Aim. The paper discusses the improvement of methods of hydrobiological studies by modifying tools for plankton and benthic samples collecting. Methods. In order to improve the standard methods of hydro-biological research, we have developed tools for sampling zooplankton and benthic environment of the Caspian Sea. Results. Long-term practice of selecting hydrobiological samples in the Caspian Sea shows that it is required to complete the modernization of the sampling tools used to collect hydrobiological material. With the introduction of Azov and Black Sea invasive comb jelly named Mnemiopsis leidyi A. Agassiz to the Caspian Sea there is a need to collect plankton samples without disturbing its integrity. Tools for collecting benthic fauna do not always give a complete picture of the state of benthic ecosystems because of the lack of visual site selection for sampling. Moreover, while sampling by dredge there is a probable loss of the samples, especially in areas with difficult terrain. Conclusion. We propose to modify a small model of Upstein net (applied in shallow water to collect zooplankton samples with an upper inverted cone that will significantly improve the catchability of the net in theCaspian Sea. Bottom sampler can be improved by installing a video camera for visual inspection of the bottom topography, and use sensors to determine tilt of the dredge and the position of the valves of the bucket. 

  3. Review: Henry E. Brady & David Collier (Eds. (2004. Rethinking Social Inquiry: Diverse Tools, Shared Standards

    Directory of Open Access Journals (Sweden)

    Matthias Catón

    2006-03-01

    Full Text Available The book Rethinking Social Inquiry, edited by Henry E. BRADY and David COLLIER, is a response to a book by KING, KEOHANE and VERBA (1994 that aimed to introduce quantitative standards to qualitative research. The authors of the book reviewed here criticize many of the suggestions made there because they argue that qualitative research requires other tools. Nevertheless, they agree that the foundations of research design are similar. The book comprises a comprehensive critique of mainstream quantitative techniques, describes a set of qualitative tools for research, and addresses issues of how to combine qualitative and quantitative approaches to maximize analytical leverage. It is an excellent contribution to the methodological debate in the social sciences. URN: urn:nbn:de:0114-fqs0602309

  4. Developing an automated database for monitoring ultrasound- and computed tomography-guided procedure complications and diagnostic yield.

    Science.gov (United States)

    Itri, Jason N; Jones, Lisa P; Kim, Woojin; Boonn, William W; Kolansky, Ana S; Hilton, Susan; Zafar, Hanna M

    2014-04-01

    Monitoring complications and diagnostic yield for image-guided procedures is an important component of maintaining high quality patient care promoted by professional societies in radiology and accreditation organizations such as the American College of Radiology (ACR) and Joint Commission. These outcome metrics can be used as part of a comprehensive quality assurance/quality improvement program to reduce variation in clinical practice, provide opportunities to engage in practice quality improvement, and contribute to developing national benchmarks and standards. The purpose of this article is to describe the development and successful implementation of an automated web-based software application to monitor procedural outcomes for US- and CT-guided procedures in an academic radiology department. The open source tools PHP: Hypertext Preprocessor (PHP) and MySQL were used to extract relevant procedural information from the Radiology Information System (RIS), auto-populate the procedure log database, and develop a user interface that generates real-time reports of complication rates and diagnostic yield by site and by operator. Utilizing structured radiology report templates resulted in significantly improved accuracy of information auto-populated from radiology reports, as well as greater compliance with manual data entry. An automated web-based procedure log database is an effective tool to reliably track complication rates and diagnostic yield for US- and CT-guided procedures performed in a radiology department.

  5. Bicuspid aortic valves: Diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, David J., E-mail: david.murphy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); McEvoy, Sinead H., E-mail: s.mcevoy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); Iyengar, Sri, E-mail: sri.iyengar@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Feuchtner, Gudrun, E-mail: Gudrun.Feuchtner@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck (Austria); Cury, Ricardo C., E-mail: r.cury@baptisthealth.net [Department of Radiology, Baptist Cardiac and Vascular Institute, 8900 North Kendall Drive, Miami, FL 33176 (United States); Roobottom, Carl, E-mail: carl.roobottom@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Plymouth University Peninsula Schools of Medicine and Dentistry (United Kingdom); Baumueller, Stephan, E-mail: Hatem.Alkadhi@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Alkadhi, Hatem, E-mail: stephan.baumueller@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Dodd, Jonathan D., E-mail: jonniedodd@gmail.com [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland)

    2014-08-15

    Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥3.8 cm{sup 2}, 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54–1.0), 100%, 100% and 70% respectively. Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT

  6. Developing and Standardization of a Diagnostic Reading Test

    Directory of Open Access Journals (Sweden)

    Tahereh Sima-Shirazi

    2004-06-01

    Full Text Available Objective: This paper is a report on the development, structure and content of a diagnostic dyslexia reading test. The target population of this test is persian children who have problems in learning reading and may be considered as dyslexic. This diagnostic test is the first reading test developed for the native speakers of persian. Materials & Methods: The theoretical framework of the test is based on two well- established reading tests for the English speaking children, namely Durrell Analysis of Reading and Neale Analysis of Reading Ability. The linguistic content of the subtests is selected from the vocabulary and texts of the textbook used in the primary schools. Both the vocabulary and the sentences of the parrallel passeges were controlled for frequency, phonemic/graphemic regularity, syllable structure, morphology, syntax and semantics. They were also controlled for value judgement by two linguistics and three first grader teachers.The first version of the test is normed on 605 boy and girl first graders from different educational sectors and schools selected randomly.The method used in this research is cross- sectional, descriptive- analytic and the data analysis is based on pearson, and mann-whitney u. Results: Reliability of the test is calculated based on parrallel forms (~ 90% and validity is based on content validity.This test has a supplementary section including spelling, graphem/ phoneme correspondness, nonword reading, irregular word reading, and copy subtests. Conclusion: Considering highreliability and precise validation of the test it can be used to diagnose the dyslexia and related linguistic impairments.

  7. Ultrasonography as a diagnostic tool in assessing deltoid ligament injury in supination external rotation fractures of the ankle.

    LENUS (Irish Health Repository)

    Henari, Shwan

    2011-10-01

    The medial deltoid ligament is the primary stabilizing structure in the ankle joint following lateral malleolar fracture. However, medial deltoid ligament ruptures are difficult to diagnose using current imaging modalities. We hypothesized that ultrasonography can be used to accurately allow early clinical assessment of ankle fracture stability, thereby negating the need to perform plain film stress views of the acutely injured ankle. This prospective study included 12 patients (age range, 18-72) with supination external rotation fractures requiring operative fixation. Following induction of anesthesia, ultrasonography examination was performed, followed by an arthrogram under fluoroscopic screening. Radiographs, ultrasonography, and arthrographic findings were compared. There was 100% correlation between ultrasonography and arthrogram findings. Ultrasonography accurately diagnosed medial deltoid rupture with a sensitivity of 100% and specificity of 100%. Plain film radiographs of the ankle had a sensitivity of 57.1% and a specificity of 60%. The difference between these was significant (χ(2)=.0091). This study demonstrates diagnostic ultrasonography to be an accurate diagnostic modality in assessing medial deltoid ligament integrity in patients with supination external rotation fractures. It offers the same sensitivity and specificity as arthrography without the need for additional invasive procedures. Its relative ease of use and lack of ionizing radiation make it a potentially useful tool, particularly in a busy trauma service.

  8. Characterizing the intrinsic bioremediation potential of 1,4-dioxane and trichloroethene using innovative environmental diagnostic tools.

    Science.gov (United States)

    Chiang, Sheau-Yun Dora; Mora, Rebecca; Diguiseppi, William H; Davis, Greg; Sublette, Kerry; Gedalanga, Phillip; Mahendra, Shaily

    2012-09-01

    An intrinsic biodegradation study involving the design and implementation of innovative environmental diagnostic tools was conducted to evaluate whether monitored natural attenuation (MNA) could be considered as part of the remedial strategy to treat an aerobic aquifer contaminated with 1,4-dioxane and trichloroethene (TCE). In this study, advanced molecular biological and stable isotopic tools were applied to confirm in situ intrinsic biodegradation of 1,4-dioxane and TCE. Analyses of Bio-Trap® samplers and groundwater samples collected from monitoring wells verified the abundance of bacteria and enzymes capable of aerobically degrading TCE and 1,4-dioxane. Furthermore, phospholipid fatty acid analysis with stable isotope probes (PLFA-SIP) of the microbial community validated the ability for microbial degradation of TCE and 1,4-dioxane. Compound specific isotope analysis (CSIA) of groundwater samples for TCE resulted in δ(13)C values that indicated likely biodegradation of TCE in three of the four monitoring wells sampled. Results of the MNA evaluation showed that enzymes capable of aerobically degrading TCE and 1,4-dioxane were present, abundant, and active in the aquifer. Taken together, these results provide direct evidence of the occurrence of TCE and 1,4-dioxane biodegradation at the study site, supporting the selection of MNA as part of the final remedy at some point in the future.

  9. Recent diagnostic developments on LHD

    International Nuclear Information System (INIS)

    Sudo, S.; Nagayama, Y.; Peterson, B.J.

    2003-01-01

    Standard diagnostics for fundamental plasma parameters and for plasma physics are routinely utilized for daily operation and physics study in the large helical device (LHD) with high reliability. Diagnostics for steady state plasma are intensively developed, especially for T e , n e (YAG laser Thomson, CO 2 laser polarimeter), data acquisition in steady state, heat resistant probes. To clarify the plasma property of the helical structure, 2-D or 3-D diagnostics are intensively developed: Tangential cameras (Fast SX TV, Photon counting CCD, H α TV); Tomography (Tangential SX CCD, Bolometer); Imaging (Bolometer, ECE, Reflectometer). Divertor and edge physics are one of important key issues for steady state operation. Diagnostics for neutral flux (H α array, Zeeman spectroscopy) and n e (Fast scanning probe, Li beam probe, Pulsed radar reflectometer). In addition to these, advanced diagnostics are being intensively developed with national and international collaborations in LHD. (author)

  10. Using the Nursing Culture Assessment Tool (NCAT) in Long-Term Care: An Update on Psychometrics and Scoring Standardization.

    Science.gov (United States)

    Kennerly, Susan; Heggestad, Eric D; Myers, Haley; Yap, Tracey L

    2015-07-29

    An effective workforce performing within the context of a positive cultural environment is central to a healthcare organization's ability to achieve quality outcomes. The Nursing Culture Assessment Tool (NCAT) provides nurses with a valid and reliable tool that captures the general aspects of nursing culture. This study extends earlier work confirming the tool's construct validity and dimensionality by standardizing the scoring approach and establishing norm-referenced scoring. Scoring standardization provides a reliable point of comparison for NCAT users. NCAT assessments support nursing's ability to evaluate nursing culture, use results to shape the culture into one that supports change, and advance nursing's best practices and care outcomes. Registered nurses, licensed practical nurses, and certified nursing assistants from 54 long-term care facilities in Kentucky, Nevada, North Carolina, and Oregon were surveyed. Confirmatory factor analysis yielded six first order factors forming the NCAT's subscales (Expectations, Behaviors, Teamwork, Communication, Satisfaction, Commitment) (Comparative Fit Index 0.93) and a second order factor-The Total Culture Score. Aggregated facility level comparisons of observed group variance with expected random variance using rwg(J) statistics is presented. Normative scores and cumulative rank percentages and how the NCAT can be used in implementing planned change are provided.

  11. Beam Instrumentation and Diagnostics

    CERN Document Server

    Strehl, Peter

    2006-01-01

    This treatise covers all aspects of the design and the daily operations of a beam diagnostic system for a large particle accelerator. A very interdisciplinary field, it involves contributions from physicists, electrical and mechanical engineers and computer experts alike so as to satisfy the ever-increasing demands for beam parameter variability for a vast range of operation modi and particles. The author draws upon 40 years of research and work, most of them spent as the head of the beam diagnostics group at GSI. He has illustrated the more theoretical aspects with many real-life examples that will provide beam instrumentation designers with ideas and tools for their work.

  12. Pilot randomized crossover study comparing the efficacy of transnasal disposable endosheath with standard endoscopy to detect Barrett's esophagus.

    Science.gov (United States)

    Shariff, Mohammed K; Varghese, Sibu; O'Donovan, Maria; Abdullahi, Zarah; Liu, Xinxue; Fitzgerald, Rebecca C; di Pietro, Massimiliano

    2016-02-01

    The transnasal endosheath endoscope is a new disposable technology with potential applicability to the primary care setting. The aim of this study was to evaluate the efficacy of transnasal endosheath endoscopy (TEE) for the detection of Barrett's esophagus, by comparing the diagnostic accuracy of TEE with that of standard endoscopy. This was a prospective, randomized, crossover study performed in a single tertiary referral center. Consecutive patients undergoing surveillance for Barrett's esophagus or referred for diagnostic assessment were recruited. All patients were randomized to undergo TEE followed by standard endoscopy or the reverse. Endoscopy experiences and patient preferences were evaluated using a questionnaire. Endoscopic and histologic diagnosis of Barrett's esophagus, and optical image quality of both endoscopic procedures, were compared. A total of 21 of 25 patients completed the study. TEE had sensitivity and specificity of 100 % for an endoscopic diagnosis of Barrett's esophagus, and of 66.7 % and 100 %, respectively, for the histologic diagnosis of Barrett's esophagus. The mean optical quality of standard endoscopy was significantly better than that of TEE (7.11 ± 0.42 vs. 4.06 ± 0.27; P evaluation in primary care as an initial diagnostic tool. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Dentistry 4. X-ray diagnostics

    International Nuclear Information System (INIS)

    2014-01-01

    DIN pocketbook 267/4 gives an overview of the normative requirements of the new X-Ray and Radiation Protection Ordinance, which has been in effect since 1 November 2011. This DIN pocketbook is intended for anyone charged with professional responsibility for the use of ionizing radiation in dentistry, operators and users of x-ray devices, radiation protection officers, accredited experts, manufacturers as well as for anyone with an interest in radiation protection or optimal radiological diagnostics. It contains standards relating to the following areas: acceptance and constancy testing; devices for evaluating findings (monitors, film viewing devices), films, printers; archiving, designating, labelling. Adherence to the standards makes it possible to avoid distractive artefacts in x-ray images and optimise the quality of x-ray diagnostics in dentistry.

  14. Interactive Data Visualization for HIV Cohorts: Leveraging Data Exchange Standards to Share and Reuse Research Tools.

    Directory of Open Access Journals (Sweden)

    Meridith Blevins

    Full Text Available To develop and disseminate tools for interactive visualization of HIV cohort data.If a picture is worth a thousand words, then an interactive video, composed of a long string of pictures, can produce an even richer presentation of HIV population dynamics. We developed an HIV cohort data visualization tool using open-source software (R statistical language. The tool requires that the data structure conform to the HIV Cohort Data Exchange Protocol (HICDEP, and our implementation utilized Caribbean, Central and South America network (CCASAnet data.This tool currently presents patient-level data in three classes of plots: (1 Longitudinal plots showing changes in measurements viewed alongside event probability curves allowing for simultaneous inspection of outcomes by relevant patient classes. (2 Bubble plots showing changes in indicators over time allowing for observation of group level dynamics. (3 Heat maps of levels of indicators changing over time allowing for observation of spatial-temporal dynamics. Examples of each class of plot are given using CCASAnet data investigating trends in CD4 count and AIDS at antiretroviral therapy (ART initiation, CD4 trajectories after ART initiation, and mortality.We invite researchers interested in this data visualization effort to use these tools and to suggest new classes of data visualization. We aim to contribute additional shareable tools in the spirit of open scientific collaboration and hope that these tools further the participation in open data standards like HICDEP by the HIV research community.

  15. Bayesian spatio-temporal modeling of Schistosoma japonicum prevalence data in the absence of a diagnostic 'gold' standard.

    Science.gov (United States)

    Wang, Xian-Hong; Zhou, Xiao-Nong; Vounatsou, Penelope; Chen, Zhao; Utzinger, Jürg; Yang, Kun; Steinmann, Peter; Wu, Xiao-Hua

    2008-06-11

    Spatial modeling is increasingly utilized to elucidate relationships between demographic, environmental, and socioeconomic factors, and infectious disease prevalence data. However, there is a paucity of studies focusing on spatio-temporal modeling that take into account the uncertainty of diagnostic techniques. We obtained Schistosoma japonicum prevalence data, based on a standardized indirect hemagglutination assay (IHA), from annual reports from 114 schistosome-endemic villages in Dangtu County, southeastern part of the People's Republic of China, for the period 1995 to 2004. Environmental data were extracted from satellite images. Socioeconomic data were available from village registries. We used Bayesian spatio-temporal models, accounting for the sensitivity and specificity of the IHA test via an equation derived from the law of total probability, to relate the observed with the 'true' prevalence. The risk of S. japonicum was positively associated with the mean land surface temperature, and negatively correlated with the mean normalized difference vegetation index and distance to the nearest water body. There was no significant association between S. japonicum and socioeconomic status of the villages surveyed. The spatial correlation structures of the observed S. japonicum seroprevalence and the estimated infection prevalence differed from one year to another. Variance estimates based on a model adjusted for the diagnostic error were larger than unadjusted models. The generated prediction map for 2005 showed that most of the former and current infections occur in close proximity to the Yangtze River. Bayesian spatial-temporal modeling incorporating diagnostic uncertainty is a suitable approach for risk mapping S. japonicum prevalence data. The Yangtze River and its tributaries govern schistosomiasis transmission in Dangtu County, but spatial correlation needs to be taken into consideration when making risk prediction at small scales.

  16. Diagnostic and prognostic utility of an inexpensive rapid on site malaria diagnostic test (ParaHIT f) among ethnic tribal population in areas of high, low and no transmission in central India

    Science.gov (United States)

    Singh, Neeru; Mishra, AK; Shukla, MM; Chand, SK; Bharti, Praveen Kumar

    2005-01-01

    Background Malaria presents a diagnostic challenge in most tropical countries. Rapid detection of the malaria parasite and early treatment of infection still remain the most important goals of disease management. Therefore, performance characteristics of the new indigenous ParaHIT f test (Span diagnostic Ltd, Surat, India) was determined among ethnic tribal population in four districts of different transmission potential in central India to assess whether this rapid diagnostic test (RDT) could be widely applied as a diagnostic tool to control malaria. Beyond diagnosis, the logical utilization of RDTs is to monitor treatment outcome. Methods A finger prick blood sample was collected from each clinically suspected case of malaria to prepare blood smear and for testing with the RDT after taking informed consent. The blood smears were read by an experienced technician blinded to the RDT results and clinical status of the subjects. The figures for specificity, sensitivity, accuracy and predictive values were calculated using microscopy as gold standard. Results The prevalence of malaria infection estimated by RDT in parallel with microscopy provide evidence of the type of high, low or no transmission in the study area. Analysis revealed (pooled data of all four epidemiological settings) that overall sensitivity, specificity and accuracy of the RDT were >90% in areas of different endemicity. While, RDT is useful to confirm the diagnosis of new symptomatic cases of suspected P. falciparum infection, the persistence of parasite antigen leading to false positives even after clearance of asexual parasitaemia has limited its utility as a prognostic tool. Conclusion The study showed that the ParaHIT f test was easy to use, reliable and cheap. Thus this RDT is an appropriate test for the use in the field by paramedical staff when laboratory facilities are not available and thus likely to contribute greatly to an effective control of malaria in resource poor countries. PMID

  17. Climate Model Diagnostic Analyzer

    Science.gov (United States)

    Lee, Seungwon; Pan, Lei; Zhai, Chengxing; Tang, Benyang; Kubar, Terry; Zhang, Zia; Wang, Wei

    2015-01-01

    The comprehensive and innovative evaluation of climate models with newly available global observations is critically needed for the improvement of climate model current-state representation and future-state predictability. A climate model diagnostic evaluation process requires physics-based multi-variable analyses that typically involve large-volume and heterogeneous datasets, making them both computation- and data-intensive. With an exploratory nature of climate data analyses and an explosive growth of datasets and service tools, scientists are struggling to keep track of their datasets, tools, and execution/study history, let alone sharing them with others. In response, we have developed a cloud-enabled, provenance-supported, web-service system called Climate Model Diagnostic Analyzer (CMDA). CMDA enables the physics-based, multivariable model performance evaluations and diagnoses through the comprehensive and synergistic use of multiple observational data, reanalysis data, and model outputs. At the same time, CMDA provides a crowd-sourcing space where scientists can organize their work efficiently and share their work with others. CMDA is empowered by many current state-of-the-art software packages in web service, provenance, and semantic search.

  18. Development and validation of an observation tool for the assessment of nursing pain management practices in intensive care unit in a standardized clinical simulation setting.

    Science.gov (United States)

    Gosselin, Emilie; Bourgault, Patricia; Lavoie, Stephan; Coleman, Robin-Marie; Méziat-Burdin, Anne

    2014-12-01

    Pain management in the intensive care unit is often inadequate. There is no tool available to assess nursing pain management practices. The aim of this study was to develop and validate a measuring tool to assess nursing pain management in the intensive care unit during standardized clinical simulation. A literature review was performed to identify relevant components demonstrating optimal pain management in adult intensive care units and to integrate them in an observation tool. This tool was submitted to an expert panel and pretested. It was then used to assess pain management practice during 26 discrete standardized clinical simulation sessions with intensive care nurses. The Nursing Observation Tool for Pain Management (NOTPaM) contains 28 statements grouped into 8 categories, which are grouped into 4 dimensions: subjective assessment, objective assessment, interventions, and reassessment. The tool's internal consistency was calculated at a Cronbach's alpha of 0.436 for the whole tool; the alpha varies from 0.328 to 0.518 for each dimension. To evaluate the inter-rater reliability, intra-class correlation coefficient was used, which was calculated at 0.751 (p nurses' pain management in a standardized clinical simulation. The NOTPaM is the first tool created for this purpose. Copyright © 2014 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  19. Radiation exposure in diagnostic medicine

    International Nuclear Information System (INIS)

    Haehnel, S.; Michalczak, H.; Reinoehl-Kompa, S.

    1995-01-01

    This volume includes the manuscripts of the papers read at the conference as well as a summary and assessment of its results. The scientific discussions were centred upon the following issues: - International surveys and comparisons of rdiation exposures in diagnostic radiology and nuclear medicine, frequency of the individual diagnostic procedures and age distribution of patients examined; - policies and regulations for the radiation protection of patients, charcteristic dosimetric values and practical usefulness of the effective dose concept during medical examinations; - assessments of the relative benefits and risks and measures to reduce the radiation exposure in the light of quality assurance aspects. The main objective of this conference not only was to evaluate the risks from diagnostic radiology and nuclear medicine but also to encourgage a critical analysis and adjustment of examination routines followed in everyday practice. Among the measures recommended were quality assurance, maintenace of international standards, development of guidelines, introduction of standard doses, improved training and professional education of personnel as well as surveys and analyses of certain examination procedures associated with substantial radiation exposure. (orig./MG) [de

  20. Portable Diagnostics Technology Assessment for Space Missions. Part 2; Market Survey

    Science.gov (United States)

    Nelson, Emily S.; Chait, Arnon

    2010-01-01

    A mission to Mars of several years duration requires more demanding standards for all onboard instruments than a 6-month mission to the Moon or the International Space Station. In Part 1, we evaluated generic technologies and suitability to NASA needs. This prior work considered crew safety, device maturity and flightworthiness, resource consumption, and medical value. In Part 2, we continue the study by assessing the current marketplace for reliable Point-of-Care diagnostics. The ultimate goal of this project is to provide a set of objective analytical tools to suggest efficient strategies for reaching specific medical targets for any given space mission as program needs, technological development, and scientific understanding evolve.

  1. Medical decision making tools: Bayesian analysis and ROC analysis

    International Nuclear Information System (INIS)

    Lee, Byung Do

    2006-01-01

    During the diagnostic process of the various oral and maxillofacial lesions, we should consider the following: 'When should we order diagnostic tests? What tests should be ordered? How should we interpret the results clinically? And how should we use this frequently imperfect information to make optimal medical decision?' For the clinicians to make proper judgement, several decision making tools are suggested. This article discusses the concept of the diagnostic accuracy (sensitivity and specificity values) with several decision making tools such as decision matrix, ROC analysis and Bayesian analysis. The article also explain the introductory concept of ORAD program

  2. Diagnostic value of adenosine deaminase in ascites for tuberculosis ascites: a meta-analysis.

    Science.gov (United States)

    Tao, Lin; Ning, Hong-Jian; Nie, Hai-Ming; Guo, Xiao-Yun; Qin, Shan-Yu; Jiang, Hai-Xing

    2014-05-01

    The diagnosis of tuberculosis (TB) ascites using standard diagnostic tools is difficult. The aim of the present meta-analysis was to establish the overall diagnostic accuracy of adenosine deaminase (ADA) levels in ascites for diagnosing TB ascites. A systematic review was performed of English language publications prior to April 2013. Sensitivity, specificity, and other measures of the accuracy of ADA for the diagnosis of TB ascites using ascites fluid were summarized using a random-effects model or a fixed-effects model. Receiver operating characteristic curves were used to summarize overall test performance. Seventeen studies involving 1797 subjects were eligible for the analysis. The summary estimates of sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and the area under cure of overall analysis were: 0.93, 0.94, 13.55, 0.11, 169.83, and 0.976, respectively; the results of sensitivity analysis of studies that used Giusti method were 0.94, 0.94, 12.99, 0.08, 183.18, and 0.977, respectively. Our results suggest that ADA in the ascites can be a sensitive and specific target and a critical criterion for the diagnosis of TB ascites. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. In-service diagnostics of pumping facilities

    International Nuclear Information System (INIS)

    Jaros, I.

    1987-01-01

    The potential is discussed of technical diagnostics in increasing operating reliability of pumping facilities of conventional and nuclear power plants, and in rationalizing the system of their maintenance. Attention is focused on the selection of diagnostic parameters in which the so-called subjective expert methodology is applied, and on the diagnostic system design. At this stage, the construction of the respective facility and the analysis of the failure rate of its individual assemblies should be considered. The selection of diagnostic means directly depends on the selection of diagnostic parameters and is conditional on other factors, such as availability, cost, technical service, and operator's training. Briefly characterized are Czechoslovak standards assessing the mechanical condition of rotary machines from the measurement of the effective value of the rate of their oscillations. (Z.M.)

  4. Evidence and diagnostic reporting in the IHE context.

    Science.gov (United States)

    Loef, Cor; Truyen, Roel

    2005-05-01

    Capturing clinical observations and findings during the diagnostic imaging process is increasingly becoming a critical step in diagnostic reporting. Standards developers-notably HL7 and DICOM-are making significant progress toward standards that enable exchanging clinical observations and findings among the various information systems of the healthcare enterprise. DICOM-like the HL7 Clinical Document Architecture (CDA) -uses templates and constrained, coded vocabulary (SNOMED, LOINC, etc.). Such a representation facilitates automated software recognition of findings and observations, intrapatient comparison, correlation to norms, and outcomes research. The scope of DICOM Structured Reporting (SR) includes many findings that products routinely create in digital form (measurements, computed estimates, etc.). In the Integrating the Healthcare Enterprise (IHE) framework, two Integration Profiles are defined for clinical data capture and diagnostic reporting: Evidence Document, and Simple Image and Numeric Report. This report describes these two DICOM SR-based integration profiles in the diagnostic reporting process.

  5. Chronic pelvic pain: how does noninvasive imaging compare with diagnostic laparoscopy?

    Science.gov (United States)

    Tirlapur, Seema A; Daniels, Jane P; Khan, Khalid S

    2015-12-01

    Chronic pelvic pain (CPP) has an annual prevalence of 38/1000 in the UK, with coexisting pathologies often present. Diagnostic laparoscopy has long been the gold standard diagnostic test, but with up to 40% showing no abnormality, we explore the value of noninvasive imaging, such as pelvic ultrasound and MRI. A literature review from inception until January 2015 of the following databases: PubMed, MEDLINE, Cumulative Index to Nursing and Allied Health Literature, Excerpta Medica database, and System for Information on Grey Literature in Europe were performed to identify published studies assessing the usefulness of ultrasound, MRI, and laparoscopy in the diagnosis of CPP. Three studies (194 women) addressed their comparative performance in patients with endometriosis, showing the sensitivity of ultrasound ranged between 58 and 88.5%; MRI was 56-91.5% and in the one study using histology as its reference standard, the sensitivity of laparoscopy was 85.7%. Noninvasive imaging has the additional benefit of being well tolerated, safer, and cheaper than surgery. CPP, by nature of its multifactorial causation, can be difficult to manage and often requires a multidisciplinary team. Ultrasound and MRI may provide information about the presence or lack of abnormality, which would allow general practitioners or office gynaecologists to initiate treatment and think about surgery as a second-line investigative tool.

  6. The european approach to quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Benini, A.

    1997-01-01

    The european and increasingly the international organizations are emphasizing the importance of appropriate quality assurance programmes in diagnostic radiology. The European Directive (particularly the directive 84/466/EURATOM). the various publications of the International Commission for radiation protection (ICRP), related to protection of the patients and workers and the Basic Safety Standards of the International Atomic Energy Agency (IAEA) might be considered the landmarks of the new approach to the problems of dose reduction and quality in diagnostic radiology. In particular ICRP maintains a watching brief on all aspects related to radiation protection and makes recommendations concerning basic principles. Since ICRP 26 (1977), several ICRP publications have dealt with all the principal fields of diagnostic radiology. The IAEA has recently published the new Basic Safety Standards including guidance levels for the most common diagnostic investigations.Within the European countries the European Union and the European legislation have strong influence of the implementation of radiation protection and Q A at a national level. This has led to a substantial effort in the european countries to establish national standards and basic quality requirements. (author)

  7. Microwave imaging for plasma diagnostics and its applications

    International Nuclear Information System (INIS)

    Mase, A.; Kogi, Y.; Ito, N.

    2007-01-01

    Microwave to millimeter-wave diagnostic techniques such as interferometry, reflectometry, scattering, and radiometry have been powerful tools for diagnosing magnetically confined plasmas. Important plasma parameters were measured to clarify the physics issues such as stability, wave phenomena, and fluctuation-induced transport. Recent advances in microwave and millimeter-wave technology together with computer technology have enabled the development of advanced diagnostics for visualization of 2D and 3D structures of plasmas. Microwave/millimeter-wave imaging is expected to be one of the most promising diagnostic methods for this purpose. We report here on the representative microwave diagnostics and their industrial applications as well as application to magnetically-confined plasmas. (author)

  8. Diagnostic Accuracy of Rating Scales for Attention-Deficit/Hyperactivity Disorder: A Meta-analysis.

    Science.gov (United States)

    Chang, Ling-Yin; Wang, Mei-Yeh; Tsai, Pei-Shan

    2016-03-01

    The Child Behavior Checklist-Attention Problem (CBCL-AP) scale and Conners Rating Scale-Revised (CRS-R) are commonly used behavioral rating scales for diagnosing attention-deficit/hyperactivity disorder (ADHD) in children and adolescents. To evaluate and compare the diagnostic performance of CBCL-AP and CRS-R in diagnosing ADHD in children and adolescents. PubMed, Ovid Medline, and other relevant electronic databases were searched for articles published up to May 2015. We included studies evaluating the diagnostic performance of either CBCL-AP scale or CRS-R for diagnosing ADHD in pediatric populations in comparison with a defined reference standard. Bivariate random effects models were used for pooling and comparing diagnostic performance. We identified and evaluated 14 and 11 articles on CBCL-AP and CRS-R, respectively. The results revealed pooled sensitivities of 0.77, 0.75, 0.72, and 0.83 and pooled specificities of 0.73, 0.75, 0.84, and 0.84 for CBCL-AP, Conners Parent Rating Scale-Revised, Conners Teacher Rating Scale-Revised, and Conners Abbreviated Symptom Questionnaire (ASQ), respectively. No difference was observed in the diagnostic performance of the various scales. Study location, age of participants, and percentage of female participants explained the heterogeneity in the specificity of the CBCL-AP. CBCL-AP and CRS-R both yielded moderate sensitivity and specificity in diagnosing ADHD. According to the comparable diagnostic performance of all examined scales, ASQ may be the most effective diagnostic tool in assessing ADHD because of its brevity and high diagnostic accuracy. CBCL is recommended for more comprehensive assessments. Copyright © 2016 by the American Academy of Pediatrics.

  9. First Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-01-01

    Considerable effort in the astronomy education research over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing astronomy as a sub-discipline of physics education research, allowing researchers to establish the initial knowledge state of students as well as to attempt to measure some of the impacts of innovative instructional interventions. Before now, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. Moving beyond the 10-year old Astronomy Diagnostics Test, we have developed and validated a new assessment instrument that is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this multiple-choice instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  10. Head-To-Head Comparison Between High- and Standard-b-Value DWI for Detecting Prostate Cancer: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup

    2018-01-01

    The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.

  11. Integration of the ITER diagnostic plant systems with CODAC

    International Nuclear Information System (INIS)

    Simrock, S.; Barnsley, R.; Bertalot, L.; Hansalia, C.; Klotz, W.D.; Makijarvi, P.; Reichle, R.; Vayakis, G.; Yonekawa, I.; Walker, C.; Wallander, A.; Walsh, M.; Winter, A.

    2011-01-01

    ITER requires extensive diagnostic systems in order to meet the requirements for machine operation, protection, plasma control and physics studies. The realization of these systems is a major challenge not only because of the harsh environment and the nuclear requirements but also with respect to Instrumentation and Control (I and C) of all the 59 diagnostics plants. The Plant Systems I and C are mostly 'in-kind', i.e. procured by the seven ITER Domestic Agencies (DAs), while the Central I and C Systems are 'in-fund', i.e. procured by ITER Organization (IO). Standardization of Plant Systems I and C is of primary importance and has been one of the highest priority tasks of CODAC. The standards are published in the Plant Control Design Handbook (PCDH) which will be followed to ensure a homogeneous design, guarantee high availability and simplify maintenance and support future upgrades. Most important for a successful commissioning and operation of the ITER facility are the concepts of interfacing the diagnostics plant systems with CODAC and the standards for instrumentation and control which must be followed all contributing parties. In this paper, we will elaborate on the concepts of interfacing the diagnostics plant systems with CODAC and the standards that must be followed for the design.

  12. Modeling Complex Workflow in Molecular Diagnostics

    Science.gov (United States)

    Gomah, Mohamed E.; Turley, James P.; Lu, Huimin; Jones, Dan

    2010-01-01

    One of the hurdles to achieving personalized medicine has been implementing the laboratory processes for performing and reporting complex molecular tests. The rapidly changing test rosters and complex analysis platforms in molecular diagnostics have meant that many clinical laboratories still use labor-intensive manual processing and testing without the level of automation seen in high-volume chemistry and hematology testing. We provide here a discussion of design requirements and the results of implementation of a suite of lab management tools that incorporate the many elements required for use of molecular diagnostics in personalized medicine, particularly in cancer. These applications provide the functionality required for sample accessioning and tracking, material generation, and testing that are particular to the evolving needs of individualized molecular diagnostics. On implementation, the applications described here resulted in improvements in the turn-around time for reporting of more complex molecular test sets, and significant changes in the workflow. Therefore, careful mapping of workflow can permit design of software applications that simplify even the complex demands of specialized molecular testing. By incorporating design features for order review, software tools can permit a more personalized approach to sample handling and test selection without compromising efficiency. PMID:20007844

  13. Species-specific nested PCR as a diagnostic tool for Brucella ovis infection in rams

    Directory of Open Access Journals (Sweden)

    L.F. Costa

    2013-02-01

    Full Text Available The aim of the present study was to evaluate a species-specific nested PCR based on a previously described species-specific PCR for detection of B. ovis in semen and urine samples of experimentally infected rams. The performance of the species-specific nested PCR was compared with the results of a genus-specific PCR. Fourteen rams were experimentally infected with the Brucella ovis REO 198 strain and samples of semen and urine were collected every week up to 180 days post infection. Out of 83 semen samples collected, 42 (50.6% were positive for the species-specific nested PCR, and 23 (27.7% were positive for the genus-specific PCR. Out of 75 urine samples, 49 (65.3% were positive for the species-specific nested PCR, whereas 11 (14.6% were genus-specific PCR positive. Species-specific nested PCR was significantly more sensitive (P<0.001 than the genus-specific PCR in semen and urine from experimentally infected rams. In conclusion, the species-specific nested PCR developed in this study may be used as a diagnostic tool for the detection of B. ovis in semen and urine samples from suspected rams.

  14. Good Practice Standards – a Regulation Tool

    DEFF Research Database (Denmark)

    Sørensen, Marie Jull

    2013-01-01

    The purpose of this article is to identify the considerations weighed in regulation with good practice standards. In this article, potential due process problems with regulation via legal standards are identified and compared to other considerations, which this regulation technique meets....

  15. Radiation effects in IFMIF Li target diagnostic systems

    International Nuclear Information System (INIS)

    Molla, J.; Vila, R.; Shikama, T.; Horiike, H.; Simakov, S.; Ciotti, M.; Ibarra, A.

    2009-01-01

    Diagnostics for the lithium target will be crucial for the operation of IFMIF. Several parameters as the lithium temperature, target thickness or wave pattern must be monitored during operation. Radiation effects may produce malfunctioning in any of these diagnostics due to the exposure to high radiation fields. The main diagnostic systems proposed for the operation of IFMIF are reviewed in this paper from the point of view of radiation damage. The main tools for the assessment of the performance of these diagnostics are the neutronics calculations by using specialised codes and the information accumulated during the last decades on the radiation effects in functional materials, components and diagnostics for ITER. This analysis allows to conclude that the design of some of the diagnostic systems must be revised to assure the high availability required for the target system.

  16. Alternative affinity tools: more attractive than antibodies?

    NARCIS (Netherlands)

    Ruigrok, V.J.B.; Levisson, M.; Eppink, M.H.M.; Smidt, H.; Oost, van der J.

    2011-01-01

    Antibodies are the most successful affinity tools used today, in both fundamental and applied research (diagnostics, purification and therapeutics). Nonetheless, antibodies do have their limitations, including high production costs and low stability. Alternative affinity tools based on nucleic acids

  17. 3D cutting tool-wear monitoring in the process

    Energy Technology Data Exchange (ETDEWEB)

    Cerce, Luka; Pusavec, Franci; Kopac Janez [University of Ljubljana, Askerceva (Slovenia)

    2015-09-15

    The tool-wear of cutting tools has a very strong impact on the product quality as well as efficiency of the machining processes. Therefore, it in-the process characterization is crucial. This paper presents an innovative and reliable direct measuring procedure for measuring spatial cutting tool-wear with usage of laser profile sensor. The technique provides possibility for determination of 3D wear profiles, as advantage to currently used 2D techniques. The influence of the orientation of measurement head on the accuracy and the amount of captured reliable data was examined and the optimal setup of the measuring system was defined. Further, a special clamping system was designed to mount the measurement device on the machine tool turret. To test the measurement system, tool-life experiment was performed. Additionally, a new tool-life criterion was developed, including spatial characteristics of the tool-wear. The results showed that novel tool-wear and tool-life diagnostic represent objective and robust estimator of the machining process. Additionally, such automation of tool-wear diagnostics on machine tool provides higher productivity and quality of the machining process.

  18. Improvement of malaria diagnostic system based on acridine orange staining.

    Science.gov (United States)

    Kimura, Masatsugu; Teramoto, Isao; Chan, Chim W; Idris, Zulkarnain Md; Kongere, James; Kagaya, Wataru; Kawamoto, Fumihiko; Asada, Ryoko; Isozumi, Rie; Kaneko, Akira

    2018-02-07

    Rapid diagnosis of malaria using acridine orange (AO) staining and a light microscope with a halogen lamp and interference filter was deployed in some malaria-endemic countries. However, it has not been widely adopted because: (1) the lamp was weak as an excitation light and the set-up did not work well under unstable power supply; and, (2) the staining of samples was frequently inconsistent. The halogen lamp was replaced by a low-cost, blue light-emitting diode (LED) lamp. Using a reformulated AO solution, the staining protocol was revised to make use of a concentration gradient instead of uniform staining. To evaluate this new AO diagnostic system, a pilot field study was conducted in the Lake Victoria basin in Kenya. Without staining failure, malaria infection status of about 100 samples was determined on-site per one microscopist per day, using the improved AO diagnostic system. The improved AO diagnosis had both higher overall sensitivity (46.1 vs 38.9%: p = 0.08) and specificity (99.0 vs 96.3%) than the Giemsa method (N = 1018), using PCR diagnosis as the standard. Consistent AO staining of thin blood films and rapid evaluation of malaria parasitaemia with the revised protocol produced superior results relative to the Giemsa method. This AO diagnostic system can be set up easily at low cost using an ordinary light microscope. It may supplement rapid diagnostic tests currently used in clinical settings in malaria-endemic countries, and may be considered as an inexpensive tool for case surveillance in malaria-eliminating countries.

  19. Multirule Based Diagnostic Approach for the Fog Predictions Using WRF Modelling Tool

    Directory of Open Access Journals (Sweden)

    Swagata Payra

    2014-01-01

    Full Text Available The prediction of fog onset remains difficult despite the progress in numerical weather prediction. It is a complex process and requires adequate representation of the local perturbations in weather prediction models. It mainly depends upon microphysical and mesoscale processes that act within the boundary layer. This study utilizes a multirule based diagnostic (MRD approach using postprocessing of the model simulations for fog predictions. The empiricism involved in this approach is mainly to bridge the gap between mesoscale and microscale variables, which are related to mechanism of the fog formation. Fog occurrence is a common phenomenon during winter season over Delhi, India, with the passage of the western disturbances across northwestern part of the country accompanied with significant amount of moisture. This study implements the above cited approach for the prediction of occurrences of fog and its onset time over Delhi. For this purpose, a high resolution weather research and forecasting (WRF model is used for fog simulations. The study involves depiction of model validation and postprocessing of the model simulations for MRD approach and its subsequent application to fog predictions. Through this approach model identified foggy and nonfoggy days successfully 94% of the time. Further, the onset of fog events is well captured within an accuracy of 30–90 minutes. This study demonstrates that the multirule based postprocessing approach is a useful and highly promising tool in improving the fog predictions.

  20. Machine Tool Advanced Skills Technology (MAST). Common Ground: Toward a Standards-Based Training System for the U.S. Machine Tool and Metal Related Industries. Volume 11: Computer-Aided Manufacturing & Advanced CNC, of a 15-Volume Set of Skill Standards and Curriculum Training Materials for the Precision Manufacturing Industry.

    Science.gov (United States)

    Texas State Technical Coll., Waco.

    This document is intended to help education and training institutions deliver the Machine Tool Advanced Skills Technology (MAST) curriculum to a variety of individuals and organizations. MAST consists of industry-specific skill standards and model curricula for 15 occupational specialty areas within the U.S. machine tool and metals-related…

  1. Metrology of radiation doses in diagnostic radiology

    International Nuclear Information System (INIS)

    Leclet, H.

    2016-01-01

    This article recalls how to calculate effective and equivalent doses in radiology from the measured value of the absorbed dose. The 97/43 EURATOM directive defines irradiation standards for diagnostic radiology (NRD) as the value of the radiation dose received by the patient's skin when the diagnostic exam is performed. NRD values are standard values that can be exceeded only with right medical or technical reasons, they are neither limit values nor optimized values. The purpose of NRD values is to avoid the over-irradiation of patients and to homogenize radiologists' practices. French laws impose how and when radiologists have to calculate the radiation dose received by the patient's skin. The calculated values have to be compared with NRD values and any difference has to be justified. A table gives NRD values for all diagnostic exams. (A.C.)

  2. Development of an Internal Real-Time Wireless Diagnostic Tool for a Proton Exchange Membrane Fuel Cell.

    Science.gov (United States)

    Lee, Chi-Yuan; Chen, Chia-Hung; Tsai, Chao-Hsuan; Wang, Yu-Syuan

    2018-01-13

    To prolong the operating time of unmanned aerial vehicles which use proton exchange membrane fuel cells (PEMFC), the performance of PEMFC is the key. However, a long-term operation can make the Pt particles of the catalyst layer and the pollutants in the feedstock gas bond together (e.g., CO), so that the catalyst loses reaction activity. The performance decay and aging of PEMFC will be influenced by operating conditions, temperature, flow and CO concentration. Therefore, this study proposes the development of an internal real-time wireless diagnostic tool for PEMFC, and uses micro-electro-mechanical systems (MEMS) technology to develop a wireless and thin (PEMFC; (5) customized design and development. The flexible integrated microsensor is embedded in the PEMFC, three important physical quantities in the PEMFC, which are the temperature, flow and CO, can be measured simultaneously and instantly, so as to obtain the authentic and complete reaction in the PEMFC to enhance the performance of PEMFC and to prolong the service life.

  3. Tracer methodology: an appropriate tool for assessing compliance with accreditation standards?

    Science.gov (United States)

    Bouchard, Chantal; Jean, Olivier

    2017-10-01

    Tracer methodology has been used by Accreditation Canada since 2008 to collect evidence on the quality and safety of care and services, and to assess compliance with accreditation standards. Given the importance of this methodology in the accreditation program, the objective of this study is to assess the quality of the methodology and identify its strengths and weaknesses. A mixed quantitative and qualitative approach was adopted to evaluate consistency, appropriateness, effectiveness and stakeholder synergy in applying the methodology. An online questionnaire was sent to 468 Accreditation Canada surveyors. According to surveyors' perceptions, tracer methodology is an effective tool for collecting useful, credible and reliable information to assess compliance with Qmentum program standards and priority processes. The results show good coherence between methodology components (appropriateness of the priority processes evaluated, activities to evaluate a tracer, etc.). The main weaknesses are the time constraints faced by surveyors and management's lack of cooperation during the evaluation of tracers. The inadequate amount of time allowed for the methodology to be applied properly raises questions about the quality of the information obtained. This study paves the way for a future, more in-depth exploration of the identified weaknesses to help the accreditation organization make more targeted improvements to the methodology. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. The use of magnetic resonance tomography in gastrointestinal diagnostics

    International Nuclear Information System (INIS)

    Geitung, Jonn Terje

    2000-01-01

    Background: Magnetic resonance imaging (MRI) is a promising method for examination of the gastrointestinal tract. In this article we present the present status and potential of MRI. Material and method: The review is based on personal experience and selected published, international papers. Results: Magnetic resonance cholangio-pancreatography (MRCP) and MRI of the liver are well documented examinations which are widely performed. These examinations partly replace existing modalities such as CT and ERCP and represent additional possibilities for examining this anatomic area. MRI is not as yet accepted as the standard examination of the pancreas, but it is regarded as comparable to CT. The adrenals may be examined even more accurately with MRI than with CT. MRI examinations of the oesophagus and gastric ventricle seem promising, but it should be said that they are in an early and not well document phase. MRI of the small and large bowels is not common. With the exception of preoperative staging of rectal cancers, it is still experimental. MR angiography, functional MRI studies and perfusion studies are not yet common in abdominal diseases. We may, however, believe that they will become important diagnostic tools. Interpretation: MRI is rapidly increasing its share of gastrointestinal imaging examinations. This is mainly due to the increased speed of newer machines. The diagnostic quality has improved and will improve more. It is thus likely that MRI will, in a large amount of abdominal imaging, replace CT and to some extent other diagnostic modalities. It is, however, not possible to replace CT for emergencies and we will probably look forward to more and better imaging with more diagnostic modalities in the future

  5. Diagnostic value of polymerase chain reaction analysis of skin biopsies in purpura fulminans.

    Science.gov (United States)

    Beau, Caroline; Vlassova, Natalia; Sarlangue, Jean; Brissaud, Olivier; Léauté-Labrèze, Christine; Boralevi, Franck

    2013-01-01

    Even though prompt diagnosis and treatment of purpura fulminans (PF) is essential to reduce mortality, early administration of antibiotics may preclude identification of the causative agent by standard bacterial cultures and thus render definitive diagnosis impossible. Here we present a case of an infant with PF and negative bacterial cultures for whom polymerase chain reaction (PCR) analysis of a cutaneous biopsy specimen obtained 4 days after initiation of antibiotics identified the genomic sequence of Neisseria meningitidis genogroup C. When bacterial cultures fail to provide useful information, PCR of skin biopsy specimens can be a valuable diagnostic tool in PF. © 2013 Wiley Periodicals, Inc.

  6. Evaluation of reduced-dose CT for acute non-traumatic abdominal pain: evaluation of diagnostic accuracy in comparison to standard-dose CT.

    Science.gov (United States)

    Othman, Ahmed E; Bongers, Malte Niklas; Zinsser, Dominik; Schabel, Christoph; Wichmann, Julian L; Arshid, Rami; Notohamiprodjo, Mike; Nikolaou, Konstantin; Bamberg, Fabian

    2018-01-01

    Background Patients with acute non-traumatic abdominal pain often undergo abdominal computed tomography (CT). However, abdominal CT is associated with high radiation exposure. Purpose To evaluate diagnostic performance of a reduced-dose 100 kVp CT protocol with advanced modeled iterative reconstruction as compared to a linearly blended 120 kVp protocol for assessment of acute, non-traumatic abdominal pain. Material and Methods Two radiologists assessed 100 kVp and linearly blended 120 kVp series of 112 consecutive patients with acute non-traumatic pain (onset diagnostic confidence. Both 100 kVp and linearly blended 120 kVp series were quantitatively evaluated regarding radiation dose and image noise. Comparative statistics and diagnostic accuracy was calculated using receiver operating curve (ROC) statistics, with final clinical diagnosis/clinical follow-up as reference standard. Results Image quality was high for both series without detectable significant differences ( P = 0.157). Image noise and artifacts were rated low for both series but significantly higher for 100 kVp ( P ≤ 0.021). Diagnostic accuracy was high for both series (120 kVp: area under the curve [AUC] = 0.950, sensitivity = 0.958, specificity = 0.941; 100 kVp: AUC ≥ 0.910, sensitivity ≥ 0.937, specificity = 0.882; P ≥ 0.516) with almost perfect inter-rater agreement (Kappa = 0.939). Diagnostic confidence was high for both dose levels without significant differences (100 kVp 5, range 4-5; 120 kVp 5, range 3-5; P = 0.134). The 100 kVp series yielded 26.1% lower radiation dose compared with the 120 kVp series (5.72 ± 2.23 mSv versus 7.75 ± 3.02 mSv, P diagnostic accuracy for the assessment of acute non-traumatic abdominal pain.

  7. Diagnostic efficacy of standard knee magnetic resonance imaging and radiography in evaluating integrity of anterior cruciate ligament before unicompartmental knee arthroplasty.

    Science.gov (United States)

    Altınel, Levent; Er, Mehmet Serhan; Kaçar, Emre; Erten, Recep Abdullah

    2015-01-01

    The purpose of this study was to investigate the diagnostic efficacy of standard magnetic resonance imaging (MRI) and plain radiographs in determining the status of anterior cruciate ligament (ACL) for surgical decision-making processes in cases of medial unicompartmental knee arthroplasty (UKA). A total of 59 knees of 36 consecutive patients who underwent knee replacement surgery were analyzed retrospectively. MRI scans were assessed independently by 3 observers (radiologists), while the plain radiographs were evaluated by an independent radiologist. Results were compared with the intraoperative ACL status. Cross tabulation was used for descriptive statistics to analyze sensitivity, specificity, and accuracy of MRI and plain radiographs. When the same observer assessed and classified the MRI twice, the reproducibility of the classification system varied from moderate to excellent. However, the interobserver concordance was moderate. The sensitivity of MRI was 73% and the specificity was 81%, while the sensitivity and specificity of plain radiographs was 36% and 79%, respectively. The accuracy of MRI was 80%, while that of the radiographs was 71%. Detection of intact ACL may be possible on available plain radiographs without necessity for additional means such as MRI, which may cause increase costs and loss of time. In cases where there is uncertainty regarding ACL integrity in degenerative knees, although standard MRI provides additional information on ACL status, it is not of sufficient diagnostic value.

  8. Validation of the Australian Midwifery Standards Assessment Tool (AMSAT): A tool to assess midwifery competence.

    Science.gov (United States)

    Sweet, Linda; Bazargan, Maryam; McKellar, Lois; Gray, Joanne; Henderson, Amanda

    2018-02-01

    There is no current validated clinical assessment tool to measure the attainment of midwifery student competence in the midwifery practice setting. The lack of a valid assessment tool has led to a proliferation of tools and inconsistency in assessment of, and feedback on student learning. This research aimed to develop and validate a tool to assess competence of midwifery students in practice-based settings. A mixed-methods approach was used and the study implemented in two phases. Phase one involved the development of the AMSAT tool with qualitative feedback from midwifery academics, midwife assessors of students, and midwifery students. In phase two the newly developed AMSAT tool was piloted across a range of midwifery practice settings and ANOVA was used to compare scores across year levels, with feedback being obtained from assessors. Analysis of 150 AMSAT forms indicate the AMSAT as: reliable (Cronbach alpha greater than 0.9); valid-data extraction loaded predominantly onto one factor; and sensitivity scores indicating level of proficiency increased across the three years. Feedback evaluation forms (n=83) suggest acceptance of this tool for the purpose of both assessing and providing feedback on midwifery student's practice performance and competence. The AMSAT is a valid, reliable and acceptable midwifery assessment tool enables consistent assessment of midwifery student competence. This assists benchmarking across midwifery education programs. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  9. Metabolomics for laboratory diagnostics.

    Science.gov (United States)

    Bujak, Renata; Struck-Lewicka, Wiktoria; Markuszewski, Michał J; Kaliszan, Roman

    2015-09-10

    Metabolomics is an emerging approach in a systems biology field. Due to continuous development in advanced analytical techniques and in bioinformatics, metabolomics has been extensively applied as a novel, holistic diagnostic tool in clinical and biomedical studies. Metabolome's measurement, as a chemical reflection of a current phenotype of a particular biological system, is nowadays frequently implemented to understand pathophysiological processes involved in disease progression as well as to search for new diagnostic or prognostic biomarkers of various organism's disorders. In this review, we discussed the research strategies and analytical platforms commonly applied in the metabolomics studies. The applications of the metabolomics in laboratory diagnostics in the last 5 years were also reviewed according to the type of biological sample used in the metabolome's analysis. We also discussed some limitations and further improvements which should be considered taking in mind potential applications of metabolomic research and practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Knee Arthroscopy Simulation: A Randomized Controlled Trial Evaluating the Effectiveness of the Imperial Knee Arthroscopy Cognitive Task Analysis (IKACTA) Tool.

    Science.gov (United States)

    Bhattacharyya, Rahul; Davidson, Donald J; Sugand, Kapil; Bartlett, Matthew J; Bhattacharya, Rajarshi; Gupte, Chinmay M

    2017-10-04

    Virtual-reality and cadaveric simulations are expensive and not readily accessible. Innovative and accessible training adjuncts are required to help to meet training needs. Cognitive task analysis has been used extensively to train pilots and in other surgical specialties. However, the use of cognitive task analyses within orthopaedics is in its infancy. The purpose of this study was to evaluate the effectiveness of a novel cognitive task analysis tool to train novice surgeons in diagnostic knee arthroscopy in high-fidelity, phantom-limb simulation. Three expert knee surgeons were interviewed independently to generate a list of technical steps, decision points, and errors for diagnostic knee arthroscopy. A modified Delphi technique was used to generate the final cognitive task analysis. A video and a voiceover were recorded for each phase of this procedure. These were combined to produce the Imperial Knee Arthroscopy Cognitive Task Analysis (IKACTA) tool that utilizes written and audiovisual stimuli to describe each phase of a diagnostic knee arthroscopy. In this double-blinded, randomized controlled trial, a power calculation was performed prior to recruitment. Sixteen novice orthopaedic trainees who performed ≤10 diagnostic knee arthroscopies were randomized into 2 equal groups. The intervention group (IKACTA group) was given the IKACTA tool and the control group had no additional learning material. They were assessed objectively (validated Arthroscopic Surgical Skill Evaluation Tool [ASSET] global rating scale) on a high-fidelity, phantom-knee simulator. All participants, using the Likert rating scale, subjectively rated the tool. The mean ASSET score (and standard deviation) was 19.5 ± 3.7 points in the IKACTA group and 10.6 ± 2.3 points in the control group, resulting in an improvement of 8.9 points (95% confidence interval, 7.6 to 10.1 points; p = 0.002); the score was determined as 51.3% (19.5 of 38) for the IKACTA group, 27.9% (10.6 of 38) for the

  11. Bayesian spatio-temporal modeling of Schistosoma japonicum prevalence data in the absence of a diagnostic 'gold' standard.

    Directory of Open Access Journals (Sweden)

    Xian-Hong Wang

    Full Text Available BACKGROUND: Spatial modeling is increasingly utilized to elucidate relationships between demographic, environmental, and socioeconomic factors, and infectious disease prevalence data. However, there is a paucity of studies focusing on spatio-temporal modeling that take into account the uncertainty of diagnostic techniques. METHODOLOGY/PRINCIPAL FINDINGS: We obtained Schistosoma japonicum prevalence data, based on a standardized indirect hemagglutination assay (IHA, from annual reports from 114 schistosome-endemic villages in Dangtu County, southeastern part of the People's Republic of China, for the period 1995 to 2004. Environmental data were extracted from satellite images. Socioeconomic data were available from village registries. We used Bayesian spatio-temporal models, accounting for the sensitivity and specificity of the IHA test via an equation derived from the law of total probability, to relate the observed with the 'true' prevalence. The risk of S. japonicum was positively associated with the mean land surface temperature, and negatively correlated with the mean normalized difference vegetation index and distance to the nearest water body. There was no significant association between S. japonicum and socioeconomic status of the villages surveyed. The spatial correlation structures of the observed S. japonicum seroprevalence and the estimated infection prevalence differed from one year to another. Variance estimates based on a model adjusted for the diagnostic error were larger than unadjusted models. The generated prediction map for 2005 showed that most of the former and current infections occur in close proximity to the Yangtze River. CONCLUSION/SIGNIFICANCE: Bayesian spatial-temporal modeling incorporating diagnostic uncertainty is a suitable approach for risk mapping S. japonicum prevalence data. The Yangtze River and its tributaries govern schistosomiasis transmission in Dangtu County, but spatial correlation needs to be taken

  12. Characterization and Diagnostics for Photovoltaic Modules and Arrays

    DEFF Research Database (Denmark)

    Spataru, Sergiu

    part of this work were developed based on two well-known module characterization techniques, namely current-voltage (I-V) characterization, and electroluminescence imaging. he I-V based module diagnostic methods were developed by combining the strengths of light I-V and dark I-V characterization......, characterization and diagnostic methods are increasingly important in identifying and understanding the failures and degradation modes affecting PV modules and arrays, as well as developing relevant tools and tests for assessing the reliability and lifetime of PV modules. This thesis investigates diagnostic...... methods for characterizing and detecting degradation modes in crystalline silicon photovoltaic modules and arrays, and is structured into two parts. The first part of this work is focused on developing PV module characterization and diagnostic methods for use in module diagnostics and failure...

  13. Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

    International Nuclear Information System (INIS)

    Debono, Josephine C; Poulos, Ann E

    2015-01-01

    The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed tool applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice

  14. Nuances of Morphology in Myelodysplastic Diseases in the Age of Molecular Diagnostics.

    Science.gov (United States)

    Shaver, Aaron C; Seegmiller, Adam C

    2017-10-01

    Morphologic dysplasia is an important factor in diagnosis of myelodysplastic syndrome (MDS). However, the role of dysplasia is changing as new molecular genetic and genomic technologies take a more prominent place in diagnosis. This review discusses the role of morphology in the diagnosis of MDS and its interactions with cytogenetic and molecular testing. Recent changes in diagnostic criteria have attempted to standardize approaches to morphologic diagnosis of MDS, recognizing significant inter-observer variability in assessment of dysplasia. Definitive correlates between cytogenetic/molecular and morphologic findings have been described in only a small set of cases. However, these genetic and morphologic tools do play a complementary role in the diagnosis of both MDS and other myeloid neoplasms. Diagnosis of MDS requires a multi-factorial approach, utilizing both traditional morphologic as well as newer molecular genetic techniques. Understanding these tools, and the interplay between them, is crucial in the modern diagnosis of myeloid neoplasms.

  15. Update on diagnostic strategies of pulmonary embolism

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Heussel, C.P.; Thelen, M.

    1999-01-01

    Acute pulmonary embolism is a frequent disease with non-specific findings, high mortality, and multiple therapeutic options. A definitive diagnosis must be established by accurate, non-invasive, easily performed, cost-effective, and widely available imaging modalities. Conventional diagnostic strategies have relied on ventilation-perfusion scintigraphy complemented by venous imaging. If the results are inconclusive, pulmonary angiography, which is regarded as the gold standard, is to be performed. Recently, marked improvements in CT and MRI and shortcomings of scintigraphy led to an update of the diagnostic strategy. Spiral CT is successfully employed as a second-line procedure to clarify indeterminate scintigraphic results avoiding pulmonary angiography. It can also be used as a first-line screening tool if service and expertise is provided. Venous imaging is indicated if CT is inconclusive. The MRI technique can be applied as an alternative second-line test if spiral CT is not available or is contraindicated. It has the greatest potential for further developments and refinements. Echocardiography should be used as a first-line bedside examination in critical patients. If inconclusive stabilized patients undergo spiral CT, unstable patients should be referred for pulmonary angiography. Chronic thromboembolic pulmonary hypertension is a rare sequela of acute pulmonary embolism which can be cured surgically. Morphology, complications, and differential diagnoses are better illustrated by spiral CT and MRA, whereas invasive acquisition of hemodynamic data is the sole advantage of angiography. (orig.)

  16. Best practice guidelines for the use of next-generation sequencing applications in genome diagnostics: a national collaborative study of dutch genome diagnostic laboratories

    NARCIS (Netherlands)

    Weiss, Marjan M.; van der Zwaag, Bert; Jongbloed, Jan D. H.; Vogel, Maartje J.; Brüggenwirth, Hennie T.; Lekanne Deprez, Ronald H.; Mook, Olaf; Ruivenkamp, Claudia A. L.; van Slegtenhorst, Marjon A.; van den Wijngaard, Arthur; Waisfisz, Quinten; Nelen, Marcel R.; van der Stoep, Nienke

    2013-01-01

    Next-generation sequencing (NGS) methods are being adopted by genome diagnostics laboratories worldwide. However, implementing NGS-based tests according to diagnostic standards is a challenge for individual laboratories. To facilitate the implementation of NGS in Dutch laboratories, the Dutch

  17. Quantified light-induced fluorescence, review of a diagnostic tool in prevention of oral disease

    NARCIS (Netherlands)

    de Josselin de Jong, E.; Higham, S.M.; Smith, P.W.; van Daelen, C.J.; van der Veen, M.H.

    2009-01-01

    Diagnostic methods for the use in preventive dentistry are being developed continuously. Few of these find their way into general practice. Although the general trend in medicine is to focus on disease prevention and early diagnostics, in dentistry this is still not the case. Nevertheless, in dental

  18. comparative analysis of diagnostic applications of autoscan tools

    African Journals Online (AJOL)

    user

    A structured questionnaire with 3 items questions as checklist, 2 Auto scan tools were used for the study and test carried out on 5 vehicle systems at the 3 centers where Innova ... maintenance, auto- analyzers, solid work design and can-.

  19. Diagnostic radiography: A study in distancing

    International Nuclear Information System (INIS)

    Reeves, Pauline J.; Decker, Sola

    2012-01-01

    Aims: This article aims to explore the ways in which diagnostic radiographers use distancing as a tool for emotional management in radiography practice. Methods: This review utilises data from oral history interviews undertaken as part of a larger study documenting the oral history of the diagnostic radiography profession in the United Kingdom as recounted by 24 participants. Results: The results are presented as illustrative of various aspects of the role of the diagnostic radiographer including the initial choice of diagnostic radiography as a profession, the endemic use of particular terminology, the nature of the encounter in diagnostic radiography (including that of sectional imaging) and whether the role is really patient-centred. Conclusions: The article concludes by suggesting that distancing from the patient is mediated by the need for physical touch in order to position the patient for radiography and also makes the suggestion that those opting for diagnostic radiography as a career may do so because they want a profession which is more distanced from the patient and that, even where this is not the case initially, individuals are socialised into adopting the ‘feeling rules’ of the profession. The article concludes by outlining potential areas for further research.

  20. Diagnostic imaging in pregraduate integrated curricula

    International Nuclear Information System (INIS)

    Kainberger, F.; Kletter, K.

    2007-01-01

    Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

  1. [Diagnostic imaging in pregraduate integrated curricula].

    Science.gov (United States)

    Kainberger, F; Kletter, K

    2007-11-01

    Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula.

  2. XII All-Russian conference Diagnostics of high-temperature plasma. Abstracts of reports and conference program

    International Nuclear Information System (INIS)

    2007-01-01

    Abstracts of reports made on the XII All-Russian conference on high-temperature plasma diagnostics are presented. The different methods of hot plasma diagnostics are considered, namely microwave diagnostic methods, laser diagnostic techniques, X-ray plasma diagnostics and corpuscular diagnostic methods. The particular attention is given to wall plasma diagnostics and diagnostics of inertial synthesis systems. Current diagnostic tools and metrological provision for plasma diagnostics are considered. The diagnostic complexes of thermonuclear devices are described. The problems of experimental data processing are discussed [ru

  3. Differential diagnostic of the burnout syndrome.

    Science.gov (United States)

    Korczak, Dieter; Huber, Beate; Kister, Christine

    2010-07-05

    significant others (for example patients). There is no evidence for stigmatization of persons with burnout. The evidence of the majority of the studies is predominantly low. Most of the studies are descriptive and explorative. Self-assessment tools are mainly used, overall the Maslach Burnout Inventory (MBI). Objective data like medical parameters, health status, sick notes or judgements by third persons are extremely seldomly included in the studies. The sample construction is coincidental in the majority of cases, response rates are often low. Almost no longitudinal studies are available. There are insufficient results on the stability and the duration of related symptoms. The ambiguity of the burnout diagnosis is regularly neglected in the studies. The authors conclude, that (1) further research, particularly high-quality studies are needed, to broaden the understanding of the burnout syndrome. Equally (2) a definition of the burnout syndrome has to be found which goes beyond the published understanding of burnout and is based on common scientific consent. Furthermore, there is a need (3) for finding a standardized, international accepted and valid procedure for the differentiated diagnostics of burnout and for (4) developing a third party assessment tool for the diagnosis of burnout. Finally, (5) the economic effects and implication of burnout diagnostics on the economy, the health insurances and the patients have to be analysed.

  4. Differential diagnostic of the burnout syndrome

    Directory of Open Access Journals (Sweden)

    Kister, Christine

    2010-01-01

    derogation of work performance it can have also negative effects on significant others (for example patients. There is no evidence for stigmatization of persons with burnout. Discussion: The evidence of the majority of the studies is predominantly low. Most of the studies are descriptive and explorative. Self-assessment tools are mainly used, overall the Maslach Burnout Inventory (MBI. Objective data like medical parameters, health status, sick notes or judgements by third persons are extremely seldomly included in the studies. The sample construction is coincidental in the majority of cases, response rates are often low. Almost no longitudinal studies are available. There are insufficient results on the stability and the duration of related symptoms. The ambiguity of the burnout diagnosis is regularly neglected in the studies. Conclusions: The authors conclude, that (1 further research, particularly high-quality studies are needed, to broaden the understanding of the burnout syndrome. Equally (2 a definition of the burnout syndrome has to be found which goes beyond the published understanding of burnout and is based on common scientific consent. Furthermore, there is a need (3 for finding a standardized, international accepted and valid procedure for the differentiated diagnostics of burnout and for (4 developing a third party assessment tool for the diagnosis of burnout. Finally, (5 the economic effects and implication of burnout diagnostics on the economy, the health insurances and the patients have to be analysed.

  5. An Inch Deep and a Mile Wide: Electronic Tools for Savvy Administrators

    Directory of Open Access Journals (Sweden)

    Deborah Jolly

    1999-01-01

    Full Text Available Texas school administrators often lack vital knowledge of technology trends, issues and skills; therefore, they are not as effective leaders of technology introduction, integration, and management as are needed. This lack comes from three sources: 1 school administrator preparatory programs have not and do not provide technology-related courses; 2 there are few technology-related in-service training course available to administrators; and 3 many Texas administrators are geographically isolated and thus have less opportunity to interact with colleagues and less opportunity to receive training. This article presents and explains web-based resources for: 1 standards development for administrator, teacher and student technology skills and knowledge; 2 standards development for accessibility, connectivity, and software; and 3 national and state resources such as diagnostic tools, school data/statistics, and other technology-related information.

  6. Bayesian analysis of longitudinal Johne's disease diagnostic data without a gold standard test

    DEFF Research Database (Denmark)

    Wang, C.; Turnbull, B.W.; Nielsen, Søren Saxmose

    2011-01-01

    the posterior estimates of the model parameters that provide the basis for inference concerning the accuracy of the diagnostic procedure. Based on the Bayesian approach, the posterior probability distribution of the change-point onset time can be obtained and used as a criterion for infection diagnosis......-point process with a Weibull survival hazard function was used to model the progression of the hidden disease status. The model adjusted for the fixed effects of covariate variables and random effects of subject on the diagnostic testing procedure. Markov chain Monte Carlo methods were used to compute....... An application is presented to an analysis of ELISA and fecal culture test outcomes in the diagnostic testing of paratuberculosis (Johne's disease) for a Danish longitudinal study from January 2000 to March 2003. The posterior probability criterion based on the Bayesian model with 4 repeated observations has...

  7. Diagnostic and interventional angiography of superior mesenteric artery

    Energy Technology Data Exchange (ETDEWEB)

    Simonetti, G; Urigo, F; Canalis, G C; Guazzaroni, M; Caboni, M; Rossi, P; Passariello, R

    1986-01-01

    The widespread diffusion of digital imaging progressivaly reduces the indications to conventional angiography in all vascular districts. On the contrary, angiography of mesenteric arteries still works as a valid complementary diagnostic tool in granulomatous and neoplastic lesions of ileum. Today, in selected patients, angiography is the first diagnostic approach to vascular ischemic and hemorrhagic pathology of ileum; timely resort to interventional angiography improve a dramatic prognosis. 70 refs.

  8. Steps to standardization and validation of hippocampal volumetry as a biomarker in clinical trials and diagnostic criteria for Alzheimer’s disease

    Science.gov (United States)

    Jack, Clifford R; Barkhof, Frederik; Bernstein, Matt A; Cantillon, Marc; Cole, Patricia E; DeCarli, Charles; Dubois, Bruno; Duchesne, Simon; Fox, Nick C; Frisoni, Giovanni B; Hampel, Harald; Hill, Derek LG; Johnson, Keith; Mangin, Jean-François; Scheltens, Philip; Schwarz, Adam J; Sperling, Reisa; Suhy, Joyce; Thompson, Paul M; Weiner, Michael; Foster, Norman L

    2012-01-01

    Background The promise of Alzheimer’s disease (AD) biomarkers has led to their incorporation in new diagnostic criteria and in therapeutic trials; however, significant barriers exist to widespread use. Chief among these is the lack of internationally accepted standards for quantitative metrics. Hippocampal volumetry is the most widely studied quantitative magnetic resonance imaging (MRI) measure in AD and thus represents the most rational target for an initial effort at standardization. Methods and Results The authors of this position paper propose a path toward this goal. The steps include: 1) Establish and empower an oversight board to manage and assess the effort, 2) Adopt the standardized definition of anatomic hippocampal boundaries on MRI arising from the EADC-ADNI hippocampal harmonization effort as a Reference Standard, 3) Establish a scientifically appropriate, publicly available Reference Standard Dataset based on manual delineation of the hippocampus in an appropriate sample of subjects (ADNI), and 4) Define minimum technical and prognostic performance metrics for validation of new measurement techniques using the Reference Standard Dataset as a benchmark. Conclusions Although manual delineation of the hippocampus is the best available reference standard, practical application of hippocampal volumetry will require automated methods. Our intent is to establish a mechanism for credentialing automated software applications to achieve internationally recognized accuracy and prognostic performance standards that lead to the systematic evaluation and then widespread acceptance and use of hippocampal volumetry. The standardization and assay validation process outlined for hippocampal volumetry is envisioned as a template that could be applied to other imaging biomarkers. PMID:21784356

  9. Dermoscopy, Digital Dermoscopy and Other Diagnostic Tools in the Early Detection of Melanoma and Follow-up of High-risk Skin Cancer Patients.

    Science.gov (United States)

    Thomas, Luc; Puig, Susana

    2017-07-05

    Early detection is a key strategy for reducing the mortality and economic burden associated with melanoma. Dermoscopy is a non-invasive and cost-effective tool for melanoma diagnosis, which has been shown to be a reliable and sensitive method for detecting early-stage skin cancer and reducing the number of unnecessary excisions. Patients at high risk of developing melanoma require long-term surveillance. Use of digital dermoscopy follow-up of these patients has led to improved outcomes. Combined follow-up programmes using total-body photography and digital dermoscopy have led to further improvements in early diagnosis and diagnostic accuracy. Dermoscopy is now widely used by dermatologists, but the public health impact of this tool is yet to be evaluated. Despite the clear advantages of dermoscopy and digital follow-up meth-ods, dermoscopy training and access to digital dermoscopy among dermatologists and general practitioners needs to be improved.

  10. Telepsychiatry clinical decision support system used by non-psychiatrists in remote areas: Validity & reliabilityof diagnostic module

    Directory of Open Access Journals (Sweden)

    Savita Malhotra

    2017-01-01

    Interpretation & conclusions: Diagnostic tool showed acceptable to good validity and reliability when used by non-specialists at remote sites. Our findings show that diagnostic tool of the telepsychiatry application has potential to empower non-psychiatrist doctors and paramedics to diagnose psychiatric disorders accurately and reliably in remote sites.

  11. Converging Human and Malaria Vector Diagnostics with Data Management towards an Integrated Holistic One Health Approach

    Directory of Open Access Journals (Sweden)

    Konstantinos Mitsakakis

    2018-02-01

    Full Text Available Monitoring malaria prevalence in humans, as well as vector populations, for the presence of Plasmodium, is an integral component of effective malaria control, and eventually, elimination. In the field of human diagnostics, a major challenge is the ability to define, precisely, the causative agent of fever, thereby differentiating among several candidate (also non-malaria febrile diseases. This requires genetic-based pathogen identification and multiplexed analysis, which, in combination, are hardly provided by the current gold standard diagnostic tools. In the field of vectors, an essential component of control programs is the detection of Plasmodium species within its mosquito vectors, particularly in the salivary glands, where the infective sporozoites reside. In addition, the identification of species composition and insecticide resistance alleles within vector populations is a primary task in routine monitoring activities, aiming to support control efforts. In this context, the use of converging diagnostics is highly desirable for providing comprehensive information, including differential fever diagnosis in humans, and mosquito species composition, infection status, and resistance to insecticides of vectors. Nevertheless, the two fields of human diagnostics and vector control are rarely combined, both at the diagnostic and at the data management end, resulting in fragmented data and mis- or non-communication between various stakeholders. To this direction, molecular technologies, their integration in automated platforms, and the co-assessment of data from multiple diagnostic sources through information and communication technologies are possible pathways towards a unified human vector approach.

  12. Converging Human and Malaria Vector Diagnostics with Data Management towards an Integrated Holistic One Health Approach.

    Science.gov (United States)

    Mitsakakis, Konstantinos; Hin, Sebastian; Müller, Pie; Wipf, Nadja; Thomsen, Edward; Coleman, Michael; Zengerle, Roland; Vontas, John; Mavridis, Konstantinos

    2018-02-03

    Monitoring malaria prevalence in humans, as well as vector populations, for the presence of Plasmodium , is an integral component of effective malaria control, and eventually, elimination. In the field of human diagnostics, a major challenge is the ability to define, precisely, the causative agent of fever, thereby differentiating among several candidate (also non-malaria) febrile diseases. This requires genetic-based pathogen identification and multiplexed analysis, which, in combination, are hardly provided by the current gold standard diagnostic tools. In the field of vectors, an essential component of control programs is the detection of Plasmodium species within its mosquito vectors, particularly in the salivary glands, where the infective sporozoites reside. In addition, the identification of species composition and insecticide resistance alleles within vector populations is a primary task in routine monitoring activities, aiming to support control efforts. In this context, the use of converging diagnostics is highly desirable for providing comprehensive information, including differential fever diagnosis in humans, and mosquito species composition, infection status, and resistance to insecticides of vectors. Nevertheless, the two fields of human diagnostics and vector control are rarely combined, both at the diagnostic and at the data management end, resulting in fragmented data and mis- or non-communication between various stakeholders. To this direction, molecular technologies, their integration in automated platforms, and the co-assessment of data from multiple diagnostic sources through information and communication technologies are possible pathways towards a unified human vector approach.

  13. Converging Human and Malaria Vector Diagnostics with Data Management towards an Integrated Holistic One Health Approach

    Science.gov (United States)

    Mitsakakis, Konstantinos; Hin, Sebastian; Wipf, Nadja; Coleman, Michael; Zengerle, Roland; Vontas, John; Mavridis, Konstantinos

    2018-01-01

    Monitoring malaria prevalence in humans, as well as vector populations, for the presence of Plasmodium, is an integral component of effective malaria control, and eventually, elimination. In the field of human diagnostics, a major challenge is the ability to define, precisely, the causative agent of fever, thereby differentiating among several candidate (also non-malaria) febrile diseases. This requires genetic-based pathogen identification and multiplexed analysis, which, in combination, are hardly provided by the current gold standard diagnostic tools. In the field of vectors, an essential component of control programs is the detection of Plasmodium species within its mosquito vectors, particularly in the salivary glands, where the infective sporozoites reside. In addition, the identification of species composition and insecticide resistance alleles within vector populations is a primary task in routine monitoring activities, aiming to support control efforts. In this context, the use of converging diagnostics is highly desirable for providing comprehensive information, including differential fever diagnosis in humans, and mosquito species composition, infection status, and resistance to insecticides of vectors. Nevertheless, the two fields of human diagnostics and vector control are rarely combined, both at the diagnostic and at the data management end, resulting in fragmented data and mis- or non-communication between various stakeholders. To this direction, molecular technologies, their integration in automated platforms, and the co-assessment of data from multiple diagnostic sources through information and communication technologies are possible pathways towards a unified human vector approach. PMID:29401670

  14. Tracer Equivalent Latitude: A Diagnostic Tool for Isentropic Transport Studies.

    Science.gov (United States)

    Allen, Douglas R.; Nakamura, Noboru

    2003-01-01

    Area equivalent latitude based on potential vorticity (PV) is a widely used diagnostic for isentropic transport in the stratosphere and upper troposphere. Here, an alternate method for calculating equivalent latitude is explored, namely, a numerical synthesis of a PV-like tracer from a long-term integration of the advection-diffusion equation on isentropic surfaces. It is found that the tracer equivalent latitude (TrEL) behaves much like the traditional PV equivalent latitude (PVEL) despite the simplified governing physics; this is evidenced by examining the kinematics of the Arctic lower stratospheric vortex. Yet in some cases TrEL performs markedly better as a coordinate for long-lived trace species such as ozone. These instances include analysis of lower stratospheric ozone during the Stratospheric Aerosol and Gas Experiment (SAGE) III Ozone Loss and Validation Experiment (SOLVE) campaign and three-dimensional reconstruction of total column ozone during November-December 1999 from fitted ozone-equivalent latitude relationship. It is argued that the improvement is due to the tracer being free from the diagnostic errors and certain diabatic processes that affect PV. The sensitivity of TrEL to spatial and temporal resolution, advection scheme, and driving winds is also examined.

  15. Cultural competency assessment tool for hospitals: evaluating hospitals' adherence to the culturally and linguistically appropriate services standards.

    Science.gov (United States)

    Weech-Maldonado, Robert; Dreachslin, Janice L; Brown, Julie; Pradhan, Rohit; Rubin, Kelly L; Schiller, Cameron; Hays, Ron D

    2012-01-01

    The U.S. national standards for culturally and linguistically appropriate services (CLAS) in health care provide guidelines on policies and practices aimed at developing culturally competent systems of care. The Cultural Competency Assessment Tool for Hospitals (CCATH) was developed as an organizational tool to assess adherence to the CLAS standards. First, we describe the development of the CCATH and estimate the reliability and validity of the CCATH measures. Second, we discuss the managerial implications of the CCATH as an organizational tool to assess cultural competency. We pilot tested an initial draft of the CCATH, revised it based on a focus group and cognitive interviews, and then administered it in a field test with a sample of California hospitals. The reliability and validity of the CCATH were evaluated using factor analysis, analysis of variance, and Cronbach's alphas. Exploratory and confirmatory factor analyses identified 12 CCATH composites: leadership and strategic planning, data collection on inpatient population, data collection on service area, performance management systems and quality improvement, human resources practices, diversity training, community representation, availability of interpreter services, interpreter services policies, quality of interpreter services, translation of written materials, and clinical cultural competency practices. All the CCATH scales had internal consistency reliability of .65 or above, and the reliability was .70 or above for 9 of the 12 scales. Analysis of variance results showed that not-for-profit hospitals have higher CCATH scores than for-profit hospitals in five CCATH scales and higher CCATH scores than government hospitals in two CCATH scales. The CCATH showed adequate psychometric properties. Managers and policy makers can use the CCATH as a tool to evaluate hospital performance in cultural competency and identify and target improvements in hospital policies and practices that undergird the provision

  16. 18F-DOPA PET/CT and 68Ga-DOTANOC PET/CT scans as diagnostic tools in focal congenital hyperinsulinism. A blinded evaluation

    International Nuclear Information System (INIS)

    Dahl Christiansen, Charlotte; Helleskov Rasmussen, Annett; Petersen, Henrik; Lerberg Nielsen, Anne; Detlefsen, Soenke; Brusgaard, Klaus; Rasmussen, Lars; Hovendal, Claus; Melikyan, Maria; Ekstroem, Klas; Globa, Evgenia; Christesen, Henrik Thybo

    2018-01-01

    Focal congenital hyperinsulinism (CHI) is curable by surgery, which is why identification of the focal lesion is crucial. We aimed to determine the use of 18F-fluoro-dihydroxyphenylalanine (18F-DOPA) PET/CT vs. 68Ga-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic-acid-1-Nal3 -octreotide (68Ga-DOTANOC) PET/CT as diagnostic tools in focal CHI. PET/CT scans of children with CHI admitted to Odense University Hospital between August 2005 and June 2016 were retrospectively evaluated visually and by their maximal standardized uptake values (SUV max ) by two independent examiners, blinded for clinical, surgical and pathological data. Pancreatic histology was used as the gold standard. For patients without surgery, the genetic profile served as the gold standard. Fifty-five CHI patients were examined by PET/CT (18F-DOPA n = 53, 68Ga-DOTANOC n = 18). Surgery was performed in 34 patients, no surgery in 21 patients. Fifty-one patients had a classifiable outcome, either by histology (n = 33, 22 focal lesions, 11 non-focal) or by genetics (n = 18, all non-focal). The predictive performance of 18F-DOPA PET/CT to identify focal CHI was identical by visual- and cut-off-based evaluation: sensitivity (95% CI) of 1 (0.85-1); specificity of 0.96 (0.82-0.99). The optimal 18F-DOPA PET SUV max ratio cut-off was 1.44 and the optimal 68Ga-DOTANOC PET SUV max cut-off was 6.77 g/ml. The area under the receiver operating curve was 0.98 (0.93-1) for 18F-DOPA PET vs. 0.71 (0.43-0.95) for 68Ga-DOTANOC PET (p < 0.03). In patients subjected to surgery, localization of the focal lesion was correct in 91%, and 100%, by 18F-DOPA PET/CT and 68Ga-DOTANOC PET/CT, respectively. 18F-DOPA PET/CT was excellent in predicting focal CHI and superior compared to 68Ga-DOTANOC PET/CT. Further use of 68GA-DOTANOC PET/CT in predicting focal CHI is discouraged. (orig.)

  17. 18F-DOPA PET/CT and 68Ga-DOTANOC PET/CT scans as diagnostic tools in focal congenital hyperinsulinism. A blinded evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dahl Christiansen, Charlotte; Helleskov Rasmussen, Annett [Hans Christian Andersen Children' s Hospital, Odense University Hospital, Odense (Denmark); University of Southern Denmark, Department of Clinical Research, Odense (Denmark); Petersen, Henrik; Lerberg Nielsen, Anne [Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark); Detlefsen, Soenke [University of Southern Denmark, Department of Clinical Research, Odense (Denmark); Odense University Hospital, Department of Pathology, Odense (Denmark); Brusgaard, Klaus [Odense University Hospital, Department of Clinical Genetics, Odense (Denmark); Rasmussen, Lars; Hovendal, Claus [Odense University Hospital, Department of Abdominal Surgery, Odense (Denmark); Melikyan, Maria [Endocrine Research Centre, Moscow (Russian Federation); Ekstroem, Klas [Karolinska Hospital, Astrid Lindgren Children' s Hospital, Stockholm (Sweden); Globa, Evgenia [MOH of Ukraine, Ukrainian Center of Endocrine Surgery, Endocrine Organs and Tissue Transplantation, Kyiv (Ukraine); Christesen, Henrik Thybo [Hans Christian Andersen Children' s Hospital, Odense University Hospital, Odense (Denmark); University of Southern Denmark, Department of Clinical Research, Odense (Denmark); Odense University Hospital, Odense Pancreas Center (OPAC), Odense (Denmark); Odense University Hospital, Department of Paediatrics, Odense C (Denmark)

    2018-02-15

    Focal congenital hyperinsulinism (CHI) is curable by surgery, which is why identification of the focal lesion is crucial. We aimed to determine the use of 18F-fluoro-dihydroxyphenylalanine (18F-DOPA) PET/CT vs. 68Ga-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic-acid-1-Nal3 -octreotide (68Ga-DOTANOC) PET/CT as diagnostic tools in focal CHI. PET/CT scans of children with CHI admitted to Odense University Hospital between August 2005 and June 2016 were retrospectively evaluated visually and by their maximal standardized uptake values (SUV{sub max}) by two independent examiners, blinded for clinical, surgical and pathological data. Pancreatic histology was used as the gold standard. For patients without surgery, the genetic profile served as the gold standard. Fifty-five CHI patients were examined by PET/CT (18F-DOPA n = 53, 68Ga-DOTANOC n = 18). Surgery was performed in 34 patients, no surgery in 21 patients. Fifty-one patients had a classifiable outcome, either by histology (n = 33, 22 focal lesions, 11 non-focal) or by genetics (n = 18, all non-focal). The predictive performance of 18F-DOPA PET/CT to identify focal CHI was identical by visual- and cut-off-based evaluation: sensitivity (95% CI) of 1 (0.85-1); specificity of 0.96 (0.82-0.99). The optimal 18F-DOPA PET SUV{sub max} ratio cut-off was 1.44 and the optimal 68Ga-DOTANOC PET SUV{sub max} cut-off was 6.77 g/ml. The area under the receiver operating curve was 0.98 (0.93-1) for 18F-DOPA PET vs. 0.71 (0.43-0.95) for 68Ga-DOTANOC PET (p < 0.03). In patients subjected to surgery, localization of the focal lesion was correct in 91%, and 100%, by 18F-DOPA PET/CT and 68Ga-DOTANOC PET/CT, respectively. 18F-DOPA PET/CT was excellent in predicting focal CHI and superior compared to 68Ga-DOTANOC PET/CT. Further use of 68GA-DOTANOC PET/CT in predicting focal CHI is discouraged. (orig.)

  18. Quantitative Electroencephalography as a Diagnostic Tool for Alzheimer's Dementia in Adults with Down Syndrome

    DEFF Research Database (Denmark)

    Salem, Lise Cronberg; Sabers, Anne; Kjaer, Troels W

    2015-01-01

    be used as a diagnostic marker for dementia. The aim of this study was to examine the value of qEEG in the diagnostic evaluation of dementia in patients with Down syndrome (DS). METHOD: The study included 21 patients with DS and mild-to-moderate dementia due to Alzheimer's disease (DS-AD) and 16 age...

  19. Report on design rules of μ-tools for hybrid tooling

    DEFF Research Database (Denmark)

    Esmoris, Jose Ignacio; Azcarate, S.; Tosello, Guido

    2011-01-01

    -effectively, especially for micro injection moulding. This particular deliverable has the objective to present the design rules for high performance μ-tools and inserts manufacture based on the new standard manufacturing process chains established during the WP 2.2 work. In particular, the achievable features, surfaces......Tooling is one of the critical stages of the process chain for polymer micro products manufacture and in particular for the COTECH process chain. Therefore, within the scope of SP2 “Tooling”, the WP 2.2 “New tool-making solutions for μ-IM and HE” is designed to investigate, develop and standardize...

  20. Out of Hours Emergency Computed Tomography Brain Studies: Comparison of Standard 3 Megapixel Diagnostic Workstation Monitors With the iPad 2.

    Science.gov (United States)

    Salati, Umer; Leong, Sum; Donnellan, John; Kok, Hong Kuan; Buckley, Orla; Torreggiani, William

    2015-11-01

    The purpose was to compare performance of diagnostic workstation monitors and the Apple iPad 2 (Cupertino, CA) in interpretation of emergency computed tomography (CT) brain studies. Two experienced radiologists interpreted 100 random emergency CT brain studies on both on-site diagnostic workstation monitors and the iPad 2 via remote access. The radiologists were blinded to patient clinical details and to each other's interpretation and the study list was randomized between interpretations on different modalities. Interobserver agreement between radiologists and intraobserver agreement between modalities was determined and Cohen kappa coefficients calculated for each. Performance with regards to urgent and nonurgent abnormalities was assessed separately. There was substantial intraobserver agreement of both radiologists between the modalities with overall calculated kappa values of 0.959 and 0.940 in detecting acute abnormalities and perfect agreement with regards to hemorrhage. Intraobserver agreement kappa values were 0.939 and 0.860 for nonurgent abnormalities. Interobserver agreement between the 2 radiologists for both diagnostic monitors and the iPad 2 was also substantial ranging from 0.821-0.860. The iPad 2 is a reliable modality in the interpretation of CT brain studies in them emergency setting and for the detection of acute and chronic abnormalities, with comparable performance to standard diagnostic workstation monitors. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.