WorldWideScience

Sample records for standard debye result

  1. Peter Debye

    Indian Academy of Sciences (India)

    1884-03-24

    In fact, the American Chemical Society chose to name its annual award for a physical chemist as the 'Peter Debye Award in Physical Chemistry'. Debye was born at Maastricht, Netherlands on March 24, 1884. His primary education was in his home town. He joined Aachen Institute of Technology (Technische Hochschule) ...

  2. Peter Debye

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 15; Issue 12. Peter Debye. E Arunan. Article-in-a-Box Volume 15 Issue 12 December 2010 pp 1056-1059 ... Author Affiliations. E Arunan1. Department of Inorganic and Physical Chemistry, Indian Institute of Science, Bangalore 560012, India.

  3. Angular Distribution and Linear Polarization of X-ray Radiation Resulting from Electron Impact Excitation of Highly Charged Ions in Debye Plasmas

    Science.gov (United States)

    Chen, Zhanbin

    2018-05-01

    Plasma-screening effects on the 1s _{1/2} → 2l (l = s , p ) and 1s _{1/2} → 3d _{3/2} electron-impact excitation of highly charged ions are investigated, together with their subsequent radiative decay. The analysis is performed based on the multi-configuration Dirac-Fock method and the fully relativistic distorted-wave method incorporating the Debye-Hückel potential. To explore the nature of the effects, calculations are carried out based on detailed analyses of the integrated total and magnetic sublevel cross sections, the alignment parameters, the linear polarizations, and the angular distribution of the X-ray photoemission, as well as on corresponding data calculated in various Debye lengths/environments, taking the 2p _{3/2}→ 1s _{1/2} and 3d _{3/2}→ 1s _{1/2} characteristic lines of H-like Fe^{25+} ion as an example. The present results are compared with experimental data and other theoretical predictions where available.

  4. Peter Debye and Electrochemistry

    Indian Academy of Sciences (India)

    The most frequent exam question related to activity coefficients… .” The importance and ... physics, mathematics and electrical engineering. His entry into chemistry was rather late, but he was a dominant figure in physical chemistry and chemical physics during the first half of the 20th century. Debye, along with Erich Hückel, ...

  5. Peter Debye and Electrochemistry

    Indian Academy of Sciences (India)

    Debye won the 1936 Nobel Prize in Chemistry for his contri- butions to molecular structure, dipole moment relationship and for diffraction of X-rays and electrons. Electrochemists, however, remember him for the Debye–Hückel limiting law that describes the behavior of strong electrolytes. In explain- ing the non-ideal ...

  6. Boundary asymptotics for a non-neutral electrochemistry model with small Debye length

    Science.gov (United States)

    Lee, Chiun-Chang; Ryham, Rolf J.

    2018-04-01

    This article addresses the boundary asymptotics of the electrostatic potential in non-neutral electrochemistry models with small Debye length in bounded domains. Under standard physical assumptions motivated by non-electroneutral phenomena in oxidation-reduction reactions, we show that the electrostatic potential asymptotically blows up at boundary points with respect to the bulk reference potential as the scaled Debye length tends to zero. The analysis gives a lower bound for the blow-up rate with respect to the model parameters. Moreover, the maximum potential difference over any compact subset of the physical domain vanishes exponentially in the zero-Debye-length limit. The results mathematically confirm the physical description that electrolyte solutions are electrically neutral in the bulk and are strongly electrically non-neutral near charged surfaces.

  7. Spectra of electron pair under harmonic and Debye potential

    Energy Technology Data Exchange (ETDEWEB)

    Munjal, D. [Department of Physics and Astrophysics, University of Delhi (India); Department of Physics, Swami Shraddhanand College, University of Delhi (India); Prasad, V. [Department of Physics, Swami Shraddhanand College, University of Delhi (India)

    2017-02-15

    Two electron systems confined by harmonic potential is known as harmonium. Such a system has been studied for many reasons in the literature. In this work we study harmonium under Debye potential. We use higher order finite difference method for the solution of Schrodinger equation. Complete energy spectrum of harmonium and harmonium under Debye potential is studied. Debye screening length shows considerable effect on the energy levels and the radial matrix elements. The results are analysed in the light of existing results and the comparison with available results shows remarkable agreement. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Elastic and piezoelectric properties, sound velocity and Debye ...

    Indian Academy of Sciences (India)

    The phase transition, the independent elastic stiffness constants, the bulk modulus, the direct and converse piezoelectric coefficients, the longitudinal, transverse, and average sound velocities, and finally the Debye temperature under pressure are studied. The results obtained are generally lower than the available ...

  9. Low temperature heat capacities and thermodynamic functions described by Debye-Einstein integrals.

    Science.gov (United States)

    Gamsjäger, Ernst; Wiessner, Manfred

    2018-01-01

    Thermodynamic data of various crystalline solids are assessed from low temperature heat capacity measurements, i.e., from almost absolute zero to 300 K by means of semi-empirical models. Previous studies frequently present fit functions with a large amount of coefficients resulting in almost perfect agreement with experimental data. It is, however, pointed out in this work that special care is required to avoid overfitting. Apart from anomalies like phase transformations, it is likely that data from calorimetric measurements can be fitted by a relatively simple Debye-Einstein integral with sufficient precision. Thereby, reliable values for the heat capacities, standard enthalpies, and standard entropies at T  = 298.15 K are obtained. Standard thermodynamic functions of various compounds strongly differing in the number of atoms in the formula unit can be derived from this fitting procedure and are compared to the results of previous fitting procedures. The residuals are of course larger when the Debye-Einstein integral is applied instead of using a high number of fit coefficients or connected splines, but the semi-empiric fit coefficients keep their meaning with respect to physics. It is suggested to use the Debye-Einstein integral fit as a standard method to describe heat capacities in the range between 0 and 300 K so that the derived thermodynamic functions are obtained on the same theory-related semi-empiric basis. Additional fitting is recommended when a precise description for data at ultra-low temperatures (0-20 K) is requested.

  10. Debye-Waller factors of fcc metals by the modified angular force model

    International Nuclear Information System (INIS)

    Kharoo, H.L.; Gupta, O.P.; Hemkar, M.P.

    1977-01-01

    A modified form of the non-central force model which takes account of the electron-ion interaction term of the Kreb's model in the Clark, Gazis and Wallis type angular forces is condidered to calculate the Debye-Waller exponents at different temperatures for five fcc metals: copper, silver, gold, aluminium and nickel. The results are compared with the available X-ray measurements in terms of the temperature parameter Y of the Debye-Waller factor, the Debye characteristic temperature thetasub(M) and the mean square displacement of the atoms. The theoretical results are found to be in reasonably satisfactory agreement with the experimental values. (orig.) [de

  11. Electron impact excitation of helium in Debye plasma

    Energy Technology Data Exchange (ETDEWEB)

    Diallo, S.; Gomis, L.; Faye, I. G.; Tall, M. S.; Diédhiou, I. [Département de Physique, Faculté des Sciences and Techniques, Université Cheikh Anta Diop, Dakar-Fann (Senegal); Diatta, C. S. [Institut International des Sciences et de Technologie, 28 Avenue des Ambassadeurs Dakar-Fann (Senegal); Zammit, M. [ARC Centre for Antimatter-Matter Studies, Curtin University, GPO Box U1987, Perth, Western Australia 6845 (Australia)

    2015-03-15

    The probability, differential, and integral scattering cross sections of the 1{sup 1}S→2{sup 1}S and 1{sup 1}S→2{sup 1}P transitions of helium have been calculated in the first Born approximation. The projectile-target interactions depending on the temperature and the density of plasma are described by the Debye-Hückel model. Wave functions of the target before and after collision were modeled by non orthogonal Hartree-Fock orbitals. The wave functions parameters are calculated with the Ritz variational method. We improve our unscreened first Born approximation integral cross sections by using the BE-scaled (B stands for binding energy and E excitation energy) method. The second Born approximation has also been used to calculate the excitation cross sections in Debye plasma. Our calculations are compared to other theoretical and experimental results where applicable.

  12. Review of quantum collision dynamics in Debye plasmas

    Directory of Open Access Journals (Sweden)

    R.K. Janev

    2016-09-01

    Full Text Available Hot, dense plasmas exhibit screened Coulomb interactions, resulting from the collective effects of correlated many-particle interactions. In the lowest particle correlation order (pair-wise correlations, the interaction between charged plasma particles reduces to the Debye–Hückel (Yukawa-type potential, characterized by the Debye screening length. Due to the importance of Coulomb interaction screening in dense laboratory and astrophysical plasmas, hundreds of theoretical investigations have been carried out in the past few decades on the plasma screening effects on the electronic structure of atoms and their collision processes employing the Debye–Hückel screening model. The present article aims at providing a comprehensive review of the recent studies in atomic physics in Debye plasmas. Specifically, the work on atomic electronic structure, photon excitation and ionization, electron/positron impact excitation and ionization, and excitation, ionization and charge transfer of ion-atom/ion collisions will be reviewed.

  13. Debye Entropic Force and Modified Newtonian Dynamics

    International Nuclear Information System (INIS)

    Li Xin; Chang Zhe

    2011-01-01

    Verlinde has suggested that the gravity has an entropic origin, and a gravitational system could be regarded as a thermodynamical system. It is well-known that the equipartition law of energy is invalid at very low temperature. Therefore, entropic force should be modified while the temperature of the holographic screen is very low. It is shown that the modified entropic force is proportional to the square of the acceleration, while the temperature of the holographic screen is much lower than the Debye temperature T D . The modified entropic force returns to the Newton's law of gravitation while the temperature of the holographic screen is much higher than the Debye temperature. The modified entropic force is connected with modified Newtonian dynamics (MOND). The constant a 0 involved in MOND is linear in the Debye frequency ω D , which can be regarded as the largest frequency of the bits in screen. We find that there do have a strong connection between MOND and cosmology in the framework of Verlinde's entropic force, if the holographic screen is taken to be bound of the Universe. The Debye frequency is linear in the Hubble constant H 0 . (geophysics, astronomy, and astrophysics)

  14. Electron plasma oscillations at arbitrary Debye lengths

    International Nuclear Information System (INIS)

    Lehnert, B.

    1990-12-01

    A solution is presented for electron plasma oscillation in a thermalized homogeneous plasma, at arbitrary ratios between the Debye length λ D and the perturbation wave length λ. The limit λ D D >> λ corresponds to the free-streaming limit of strong kinetic phase-mixing due to large particle excursions. A strong large Debye distance (LDD) effect already appears when λ D > approx λ. The initial amplitude of the fluid-like contribution to the macroscopic density perturbation then becomes small as compared to the contribution from the free-streaming part. As a consequence, only a small fraction of the density perturbation remains after a limited number of kinetic damping times of the free-streaming part. The analysis further shows that a representation in terms of normal model of the form exp(-iωt) leads to amplitude factors of these modes which are related to each other and which depend on the combined free-streaming and fluid behaviour of the plasma. Consequently, these modes are coupled and cannot be treated as being independent of each other. (au)

  15. The Temperature Dependence of the Debye-Waller Factor of Magnesium

    DEFF Research Database (Denmark)

    Sledziewska-Blocka, D.; Lebech, Bente

    1976-01-01

    The temperature dependence of the average Debye-Waller factor for magnesium was measured by means of neutron diffraction spectrometry. The experimental results obtained in the temperature range from 5 to 256 K are compared with theoretical calculations, using the harmonic and quasi-harmonic appro......The temperature dependence of the average Debye-Waller factor for magnesium was measured by means of neutron diffraction spectrometry. The experimental results obtained in the temperature range from 5 to 256 K are compared with theoretical calculations, using the harmonic and quasi...

  16. Determination of Debye temperatures and Lamb–Mössbauer factors for LnFeO3 orthoferrite perovskites (Ln  =  La, Nd, Sm, Eu, Gd)

    Science.gov (United States)

    Scrimshire, A.; Lobera, A.; Bell, A. M. T.; Jones, A. H.; Sterianou, I.; Forder, S. D.; Bingham, P. A.

    2018-03-01

    Lanthanide orthoferrites have wide-ranging industrial uses including solar, catalytic and electronic applications. Here a series of lanthanide orthoferrite perovskites, LnFeO3 (Ln  =  La Nd; Sm; Eu; Gd), prepared through a standard stoichiometric wet ball milling route using oxide precursors, has been studied. Characterisation through x-ray diffraction and x-ray fluorescence confirmed the synthesis of phase-pure or near-pure LnFeO3 compounds. 57Fe Mössbauer spectroscopy was performed over a temperature range of 10 K–293 K to observe hyperfine structure and to enable calculation of the recoil-free fraction and Debye temperature (θ D) of each orthoferrite. Debye temperatures (Ln  =  La 474 K Nd 459 K Sm 457 K Eu 452 K Gd 473 K) and recoil-free fractions (Ln  =  La 0.827; Nd 0.817; Sm 0.816; Eu 0.812; Gd 0.826) were approximated through minimising the difference in the temperature dependent experimental centre shift and theoretical isomer shift, by allowing the Debye temperature and isomer shift values to vary. This method of minimising the difference between theoretical and actual values yields Debye temperatures consistent with results from other studies determined through thermal analysis methods. This displays the ability of variable-temperature Mössbauer spectroscopy to approximate Debye temperatures and recoil-free fractions, whilst observing temperature induced transitions over the temperature range observed. X-ray diffraction and Rietveld refinement show an inverse relationship between FeO6 octahedral volume and approximated Debye temperatures. Raman spectroscopy show an increase in the band positions attributed to soft modes of Ag symmetry, Ag(3) and Ag(5) from La to GdFeO3 corresponding to octahedral rotations and tilts in the [0 1 0] and [1 0 1] planes respectively.

  17. Charge transfer in proton-hydrogen collisions under Debye plasma

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Arka [Department of Mathematics, Burdwan University, Golapbag, Burdwan 713 104, West Bengal (India); Kamali, M. Z. M. [Centre for Foundation Studies in Science, University of Malaya, 50603 Kuala Lumpur (Malaysia); Ghoshal, Arijit, E-mail: arijit98@yahoo.com [Department of Mathematics, Burdwan University, Golapbag, Burdwan 713 104, West Bengal (India); Department of Mathematics, Kazi Nazrul University, B.C.W. Campus, Asansol 713 304, West Bengal (India); Institute of Mathematical Sciences, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia); Ratnavelu, K. [Department of Mathematics, Kazi Nazrul University, B.C.W. Campus, Asansol 713 304, West Bengal (India)

    2015-02-15

    The effect of plasma environment on the 1s → nlm charge transfer, for arbitrary n, l, and m, in proton-hydrogen collisions has been investigated within the framework of a distorted wave approximation. The effect of external plasma has been incorporated using Debye screening model of the interacting charge particles. Making use of a simple variationally determined hydrogenic wave function, it has been possible to obtain the scattering amplitude in closed form. A detailed study has been made to investigate the effect of external plasma environment on the differential and total cross sections for electron capture into different angular momentum states for the incident energy in the range of 20–1000 keV. For the unscreened case, our results are in close agreement with some of the most accurate results available in the literature.

  18. Debye screening length effects of nanostructured materials

    CERN Document Server

    Ghatak, Kamakhya Prasad

    2014-01-01

    This monograph solely investigates the Debye Screening Length (DSL) in semiconductors and their nano-structures. The materials considered are quantized structures of non-linear optical, III-V, II-VI, Ge, Te, Platinum Antimonide, stressed materials, Bismuth, GaP, Gallium Antimonide, II-V and Bismuth Telluride respectively. The DSL in opto-electronic materials and their quantum confined counterparts is studied in the presence of strong light waves and intense electric fields on the basis of newly formulated electron dispersion laws that control the studies of such quantum effect devices. The suggestions for the experimental determination of 2D and 3D DSL and the importance of measurement of band gap in optoelectronic materials under intense built-in electric field in nano devices and strong external photo excitation (for measuring photon induced physical properties) have also been discussed in this context. The influence of crossed electric and quantizing magnetic fields on the DSL and the DSL in heavily doped ...

  19. CMS standard model Higgs boson results

    Directory of Open Access Journals (Sweden)

    Garcia-Abia Pablo

    2013-11-01

    Full Text Available In July 2012 CMS announced the discovery of a new boson with properties resembling those of the long-sought Higgs boson. The analysis of the proton-proton collision data recorded by the CMS detector at the LHC, corresponding to integrated luminosities of 5.1 fb−1 at √s = 7 TeV and 19.6 fb−1 at √s = 8 TeV, confirm the Higgs-like nature of the new boson, with a signal strength associated with vector bosons and fermions consistent with the expectations for a standard model (SM Higgs boson, and spin-parity clearly favouring the scalar nature of the new boson. In this note I review the updated results of the CMS experiment.

  20. A generalized Debye source approach to electromagnetic scattering in layered media

    International Nuclear Information System (INIS)

    O’Neil, Michael

    2014-01-01

    The standard solution to time-harmonic electromagnetic scattering problems in homogeneous layered media relies on the use of the electric field dyadic Green's function. However, for small values of the governing angular frequency ω, evaluation of the electric field using this Green's function exhibits numerical instability. In this short note, we provide an alternative approach which is immune from this low-frequency breakdown as ω → 0. Our approach is based on the generalized Debye source representation of Maxwell fields. Using this formulation, the electric and magnetic fields gracefully decouple in the static limit, a behavior similar to that of the classical Lorenz-Debye-Mie representation of Maxwell fields in spherical geometries. We derive extensions of both the generalized Deybe source and Lorenz-Debye-Mie representations to planar geometries, as well as provide equations for the solution of scattering from a perfectly conducting half-space and in layered media using a Sommerfeld-like approach. These formulas are stable as ω tends to zero, and offer alternatives to the electric field dyadic Green's function

  1. Calculating Debye potentials from data on I or H

    International Nuclear Information System (INIS)

    Torrence, R.J.

    1982-01-01

    Using the formalism of Cohen and Kegeles equations are obtained for arbitrary spin radiation field Debye potentials in Reissner-Nordstrom geometries, and a formal series solution is presented. For the case of integer spin the series is modified to what appears to be am more natural form. In the particular case of vanishing spin it is shown that in some important cases the modified series converges to a solution of the Debye potential equation, which is the scalar wave equation, and is simply related to characteristic initial data given on either H or I. (author)

  2. Quantum Debye-Hueckel theory and the possible plasma phase transition

    International Nuclear Information System (INIS)

    Baker, G. Jr.

    1998-01-01

    In this paper the author first sketches the calculation of the pressure of a neutral, ion-electron gas as an expansion in powers of the electron charge, e, by means of the Matsubara, finite-temperature, many-body, perturbation theory. He then goes on to derive the Debye-Hue term and other equations to support his contentions. His results support but do not prove the existence of a phase transition

  3. Debye–Einstein approximation approach to calculate the lattice specific heat and related parameters for a Si nanowire

    Directory of Open Access Journals (Sweden)

    A. KH. Alassafee

    2017-11-01

    Full Text Available The modified Debye–Einstein approximation model is used to calculate nanoscale size-dependent values of Gruneisen parameters and lattice specific heat capacity for Si nanowires. All parameters forming the model, including Debye temperatures, bulk moduli, the lattice thermal expansion and the lattice volume, are calculated according to their nanoscale size dependence. Values for lattice volume Gruneisen parameters increase with the decrease of the nanowires’ diameter, while all other parameters decrease. The nanosize dependence of lattice thermal parameters agree with other reported theoretical results. Keywords: Lattice specific heat capacity, Gruneisen parameter, Debye–Einstein model, Si nanowires

  4. Some Debye temperatures from single-crystal elastic constant data

    Science.gov (United States)

    Robie, R.A.; Edwards, J.L.

    1966-01-01

    The mean velocity of sound has been calculated for 14 crystalline solids by using the best recent values of their single-crystal elastic stiffness constants. These mean sound velocities have been used to obtain the elastic Debye temperatures ??De for these materials. Models of the three wave velocity surfaces for calcite are illustrated. ?? 1966 The American Institute of Physics.

  5. Elastic and piezoelectric properties, sound velocity and Debye ...

    Indian Academy of Sciences (India)

    As shown in figure 3, both the direct and the converse piezoelectric coefficients decrease gradually with increasing hydrostatic pressure. 3.4 Sound velocity and Debye temperature. Sound velocities in an anisotropic material are strongly dependent on the propagation directions. Two types of waves, longitudinal and shear ...

  6. Debye temperatures of uranium chalcogenides from their lattice ...

    Indian Academy of Sciences (India)

    Phonon dispersion relations in uranium chalcogenides have been investigated using a modified three-body force shell model. From the phonon frequencies, their Debye temperatures are evaluated. Further, on the basis of the spin fluctuation in the heavy fermion uranium compounds, UPt3 and UBe13, the possible ...

  7. Debye temperatures of uranium chalcogenides from their lattice ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. Phonon dispersion relations in uranium chalcogenides have been investigated using a modified three-body force shell model. From the phonon frequencies, their Debye temperatures are evaluated. Further, on the basis of the spin fluctuation in the heavy fermion uranium compounds, UPt3 and UBe13, the ...

  8. Solvent dynamical effects in electron transfer: Predicted consequences of non-Debye relaxation processes and some comparisons with experimental kinetics

    Science.gov (United States)

    McManis, George E.; Weaver, Michael J.

    1989-01-01

    The consequences of non-Debye solvent relaxation upon the barrier-crossing dynamics of adiabatic electron-transfer processes have been explored numerically using a rate formulation due to Hynes for several common forms of the dielectric response function Ê(s), with the objective of assessing the likely experimental importance of such effects. For the ``multiple Debye'' form of Ê(s), analytic expressions for the required time-correlation function can be obtained, whereas for the Davidson-Cole and Cole-Cole forms numerical solutions to the inverse Laplace transform were required. Illustrative numerical results are presented of the increases in the adiabatic barrier-crossing frequency, νn, predicted to be engendered by the presence of higher-frequency relaxation components for dielectric conditions of likely experimental relevance. Substantial (five- to ten fold) rate enhancements are often obtained, resulting from the disproportionately large influence upon νn predicted to arise from the higher-frequency components of Ê(s). Neither νn, nor the non-Debye influence upon νn, are found to be affected greatly by alterations in the shape of the barrier top caused by variations in the electronic coupling matrix element. Comparisons between these numerical predictions and corresponding experimental solvent-dependent νn values extracted from metallocene self-exchange kinetics indicate that the former can account for a substantial fraction of the νn accelerations observed in alcohols and other non-Debye solvents. Roughly concordant non-Debye effects are also predicted from some other, but not all, recent rate formulations. The desirability of utilizing subpicosecond dynamical solvation information from fluorescence Stokes shifts to predict non-Debye effects upon electron-transfer barrier-crossing frequencies is pointed out.

  9. Calculations of thermophysical properties of cubic carbides and nitrides using the Debye-Grueneisen model

    Energy Technology Data Exchange (ETDEWEB)

    Lu Xiaogang [Department of Materials Science and Engineering, Royal Institute of Technology, SE-100 44 Stockholm (Sweden)]. E-mail: xiaogang@thermocalc.se; Selleby, Malin [Department of Materials Science and Engineering, Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Sundman, Bo [Department of Materials Science and Engineering, Royal Institute of Technology, SE-100 44 Stockholm (Sweden)

    2007-02-15

    The thermal expansivities and heat capacities of MX (M = Ti, Zr, Hf, V, Nb, Ta; X = C, N) carbides and nitrides with NaCl structure were calculated using the Debye-Grueneisen model combined with ab initio calculations. Two different approximations for the Grueneisen parameter {gamma} were used in the Debye-Grueneisen model, i.e. the expressions proposed by Slater and by Dugdale and MacDonald. The thermal electronic contribution was evaluated from ab initio calculations of the electronic density of states. The calculated results were compared with CALPHAD assessments and experimental data. It was found that the calculations using the Dugdale-MacDonald {gamma} can account for most of the experimental data. By fitting experimental heat capacity and thermal expansivity data below the Debye temperatures, an estimation of Poisson's ratio was obtained and Young's and shear moduli were evaluated. In order to reach a reasonable agreement with experimental data, it was necessary to use the logarithmic averaged mass of the constituent atoms. The agreements between the calculated and the experimental values for the bulk and Young's moduli are generally better than the agreement for shear modulus.

  10. Calculations of thermophysical properties of cubic carbides and nitrides using the Debye-Grueneisen model

    International Nuclear Information System (INIS)

    Lu Xiaogang; Selleby, Malin; Sundman, Bo

    2007-01-01

    The thermal expansivities and heat capacities of MX (M = Ti, Zr, Hf, V, Nb, Ta; X = C, N) carbides and nitrides with NaCl structure were calculated using the Debye-Grueneisen model combined with ab initio calculations. Two different approximations for the Grueneisen parameter γ were used in the Debye-Grueneisen model, i.e. the expressions proposed by Slater and by Dugdale and MacDonald. The thermal electronic contribution was evaluated from ab initio calculations of the electronic density of states. The calculated results were compared with CALPHAD assessments and experimental data. It was found that the calculations using the Dugdale-MacDonald γ can account for most of the experimental data. By fitting experimental heat capacity and thermal expansivity data below the Debye temperatures, an estimation of Poisson's ratio was obtained and Young's and shear moduli were evaluated. In order to reach a reasonable agreement with experimental data, it was necessary to use the logarithmic averaged mass of the constituent atoms. The agreements between the calculated and the experimental values for the bulk and Young's moduli are generally better than the agreement for shear modulus

  11. High-T QCD and dimensional reduction measuring the Debye mass

    CERN Document Server

    Kajantie, Keijo; Peisa, J; Rajantie, A; Rummukainen, K; Shaposhnikov, Mikhail E

    1997-01-01

    We study the high-temperature phase of SU(2) and SU(3) QCD using lattice simulations of an effective 3-dimensional SU(N) + adjoint Higgs -theory, obtained through dimensional reduction. We investigate the phase diagram of the 3D theory, and find that the high-T QCD phase corresponds to the metastable symmetric phase of the 3D theory. We measure the Debye screening mass m_D with gauge invariant operators; in particular we determine the O(g^2) and O(g^3) corrections to m_D. The corrections are seen to be large, modifying the standard power-counting hierarchy in high temperature QCD.

  12. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic Systems § 493.1281 Standard:...

  13. Interpreting Results from the Standardized UXO Test Sites

    National Research Council Canada - National Science Library

    May, Michael; Tuley, Michael

    2007-01-01

    ...) and the Environmental Security Technology Certification Program (ESCTP) to complete a detailed analysis of the results of testing carried out at the Standardized Unexploded Ordnance (UXO) Test Sites...

  14. Debye-Waller factors and absorptive scattering factors of elemental crystals

    International Nuclear Information System (INIS)

    Peng, L.M.; Ren, G.; Dudarev, S.L.; Whelan, M.J.

    1996-01-01

    Debye-Waller factors and absorptive scattering factors are given of 44 elemental crystals over the temperature range from 1 to 1000 K or to the melting temperature, whichever is smaller. The Debye-Waller factors are derived from the experimentally determined phonon density of states and the accuracy of these factors is typically 2 to 3%. Necessary data have also been compiled for an additional 22 elemental crystals for which the characteristic Debye temperatures are known. These data can be used to estimate the Debye-Waller factor at any temperature using the analytical Debye expression of the phonon density of states. (orig.)

  15. Scattering Light by а Cylindrical Capsule with Arbitrary End Caps in the Rayleigh-Gans-Debye Approximation

    Directory of Open Access Journals (Sweden)

    K. A. Shapovalov

    2015-01-01

    Full Text Available The paper concerns the light scattering problem of biological objects of complicated structure.It considers optically “soft” (having a refractive index close to that of a surrounding medium homogeneous cylindrical capsules, composed of three parts: central one that is cylindrical and two symmetrical rounding end caps. Such capsules can model more broad class of biological objects than the ordinary shapes of a spheroid or sphere. But, unfortunately, if a particle has other than a regular geometrical shape, then it is very difficult or impossible to solve the scattering problem analytically in its most general form that oblige us to use numerical and approximate analytical methods. The one of such approximate analytical method is the Rayleigh-Gans-Debye approximation (or the first Born approximation.So, the Rayleigh-Gans-Debye approximation is valid for different objects having size from nanometer to millimeter and depending on wave length and refractive index of an object under small phase shift of central ray.The formulas for light scattering amplitude of cylindrical capsule with arbitrary end caps in the Rayleigh-Gans-Debye approximation in scalar form are obtained. Then the light scattering phase function [or element of scattering matrix f11] for natural incident light (unpolarized or arbitrary polarized light is calculated.Numerical results for light scattering phase functions of cylindrical capsule with conical, spheroidal, paraboloidal ends in the Rayleigh-Gans-Debye approximation are compared. Also numerical results for light scattering phase function of cylindrical capsule with conical ends in the Rayleigh-Gans-Debye approximation and in the method of Purcell-Pennypacker (or Discrete Dipole method are compared. The good agreement within an application range of the RayleighGans-Debye approximation is obtained.Further continuation of the work, perhaps, is a consideration of multilayer cylindrical capsule in the Rayleigh-Gans-Debye

  16. The primary extinction and static Debye-Waller factor in the characterization of textured nickel by X-ray diffraction

    International Nuclear Information System (INIS)

    Kryshtab, T.; Palacios G, J.; Cadena A, A.; Kryvko, A.

    2015-01-01

    The texture analysis using X-ray diffraction (XRD) implies measurement of pole figures (Pf) from the diffracted intensities considering the model of kinematical dispersion. The extinction phenomenon results in a decrease of diffracted intensity and that in turn in a decrease of pole densities (Pds). The phenomenon appears in the kinematical theory of XRD as the primary extinction and the secondary extinction to characterize the loss of intensity of kinematical dispersion. In turn, the static Debye-Waller factor is an integral characteristic of defects in crystals that is introduced in the kinematical theory of XRD and also is used in dynamical theory of XRD. In this work the correlation between the primary extinction coefficient and the static Debye-Waller factor in the case of textured nickel was determined. The value of static Debye-Waller factor was determined from the value of the calculated primary extinction coefficient. For the evaluation there were used Pds in the maxima of Pf obtained for 111 and 200 reflections with Mo Kα radiation, and the Pds in the maxima of Pf obtained for the first and second orders of these reflections with Cu Kα and Co Kα radiations. There were calculated the dislocation densities in grains using values of static Debye-Waller factor and the extinction coefficients. The dislocation densities calculated from these two characteristics are practically equal. (Author)

  17. Sheath parameters for non-Debye plasmas: Simulations and arc damage

    Directory of Open Access Journals (Sweden)

    I. V. Morozov

    2012-05-01

    Full Text Available This paper describes the surface environment of the dense plasma arcs that damage rf accelerators, tokamaks, and other high gradient structures. We simulate the dense, nonideal plasma sheath near a metallic surface using molecular dynamics (MD to evaluate sheaths in the non-Debye region for high density, low temperature plasmas. We use direct two-component MD simulations where the interactions between all electrons and ions are computed explicitly. We find that the non-Debye sheath can be extrapolated from the Debye sheath parameters with small corrections. We find that these parameters are roughly consistent with previous particle-in-cell code estimates, pointing to densities in the range 10^{24}–10^{25}  m^{-3}. The high surface fields implied by these results could produce field emission that would short the sheath and cause an instability in the time evolution of the arc, and this mechanism could limit the maximum density and surface field in the arc. These results also provide a way of understanding how the properties of the arc depend on the properties (sublimation energy, for example of the metal. Using these results, and equating surface tension and plasma pressure, it is possible to infer a range of plasma densities and sheath potentials from scanning electron microscope images of arc damage. We find that the high density plasma these results imply and the level of plasma pressure they would produce is consistent with arc damage on a scale 100 nm or less, in examples where the liquid metal would cool before this structure would be lost. We find that the submicron component of arc damage, the burn voltage, and fluctuations in the visible light production of arcs may be the most direct indicators of the parameters of the dense plasma arc, and the most useful diagnostics of the mechanisms limiting gradients in accelerators.

  18. Standardization of health informatics--results and challenges.

    Science.gov (United States)

    Klein, G O

    2002-01-01

    This review article aims to highlight the importance of standards for effective communication and provides an overview of international standardization activities. This article is based on the experience of the author of European standardization in CEN, which he leads, and the global work of ISO, where he is leading the security working group, and an overview of the work of DICOM, IEEE and HL7, partly using their web presentations. Health communication is highly dependent of the general development of information technology with standards coming from ISO/IEC JTCI, ITU and several other organizations e.g. IETF, the World Wide Web consortium and Open group. A number of standardization initiatives have been in progress for more than ten years with the aim to facilitate different aspects of the exchange of health information. Electronic record architecture, Message structures, Concept representation, Device communication including imaging and Security are the main areas. Important results have been achieved, and in some fields and parts of the world, standards are widely used today. Unfortunately, we are still facing the fact that most healthcare information systems cannot exchange information with all systems for which this would be desired. Either the existing standards are not sufficiently implemented, or the required standards and necessary national implementation guidelines do not yet exist. This causes unacceptable risks to patients, inefficient use of healthcare resources, and sub-optimal development of medical knowledge. Fortunately, the different bodies are now largely co-operating to achieve global consensus.

  19. Free-Free Transitions in the Presence of Laser Fields and Debye Potential at Very Low Incident Electron Energies

    Science.gov (United States)

    Bhatia, Anand

    2012-01-01

    We study the free-free transition in electron-helium ion in the ground state and embedded in a Debye potential in the presence of an external laser field at very low incident electron energies. The laser field is treated classically while the collision dynamics is treated quantum mechanically. The laser field is chosen as monochromatic, linearly polarized and homogeneous. The incident electron is considered to be dressed by the laser field in a nonperturbative manner by choosing Volkov wave function for it. The scattering wave function for the incident electron on the target embedded in a Debye potential is solved numerically by taking into account the effect of electron exchange. We calculate the laser-assisted differential and total cross sections for free-free transition for absorption/emission of a single photon or no photon exchange. The results will be presented at the conference.

  20. Calculation of Half-Metal, Debye and Curie Temperatures of Co2VAl Compound: First Principles Study

    Science.gov (United States)

    Arash, Boochani; Heidar, Khosravi; Jabbar, Khodadadi; Shahram, Solaymani; Masoud Majidiyan, Sarmazdeh; Rohollah Taghavi, Mendi; Sayed, Mohammad Elahi

    2015-05-01

    By FP-LAPW calculations, the structural, elastic, Debye and Curie temperatures, electronic and magnetic properties of Co2 VAl are investigated. The results indicate that Ferromagnetic (FM) phase is more stable than Anti-Ferromagnetic (AFM) and Non-magnetic (NM) ones. In addition, C11-C12 > 0, C44 > 0, and B > 0 so Co2VAl is an elastically stable material with high Debye temperature. Also, the B/G ratio exhibits a ductility behavior. The relatively high Curie temperature provides it as a favorable material for spintronic application. It's electronic and magnetic properties are studied by GGA+U approach leading to a 100% spin polarization at Fermi level. Supported by the simulation of Nano Physics Lab center of Kermanshah Branch, Islamic Azad University

  1. Review of Current Standard Model Results in ATLAS

    CERN Document Server

    Brandt, Gerhard; The ATLAS collaboration

    2018-01-01

    This talk highlights results selected from the Standard Model research programme of the ATLAS Collaboration at the Large Hadron Collider. Results using data from $p-p$ collisions at $\\sqrt{s}=7,8$~TeV in LHC Run-1 as well as results using data at $\\sqrt{s}=13$~TeV in LHC Run-2 are covered. The status of cross section measurements from soft QCD processes and jet production as well as photon production are presented. The presentation extends to vector boson production with associated jets. Precision measurements of the production of $W$ and $Z$ bosons, including a first measurement of the mass of the $W$ bosons, $m_W$, are discussed. The programme to measure electroweak processes with di-boson and tri-boson final states is outlined. All presented measurements are compatible with Standard Model descriptions and allow to further constrain it. In addition they allow to probe new physics which would manifest through extra gauge couplings, or Standard Model gauge couplings deviating from their predicted value.

  2. Use of Debye's series to determine the optimal edge-effect terms for computing the extinction efficiencies of spheroids.

    Science.gov (United States)

    Lin, Wushao; Bi, Lei; Liu, Dong; Zhang, Kejun

    2017-08-21

    The extinction efficiencies of atmospheric particles are essential to determining radiation attenuation and thus are fundamentally related to atmospheric radiative transfer. The extinction efficiencies can also be used to retrieve particle sizes or refractive indices through particle characterization techniques. This study first uses the Debye series to improve the accuracy of high-frequency extinction formulae for spheroids in the context of Complex angular momentum theory by determining an optimal number of edge-effect terms. We show that the optimal edge-effect terms can be accurately obtained by comparing the results from the approximate formula with their counterparts computed from the invariant imbedding Debye series and T-matrix methods. An invariant imbedding T-matrix method is employed for particles with strong absorption, in which case the extinction efficiency is equivalent to two plus the edge-effect efficiency. For weakly absorptive or non-absorptive particles, the T-matrix results contain the interference between the diffraction and higher-order transmitted rays. Therefore, the Debye series was used to compute the edge-effect efficiency by separating the interference from the transmission on the extinction efficiency. We found that the optimal number strongly depends on the refractive index and is relatively insensitive to the particle geometry and size parameter. By building a table of optimal numbers of edge-effect terms, we developed an efficient and accurate extinction simulator that has been fully tested for randomly oriented spheroids with various aspect ratios and a wide range of refractive indices.

  3. Comparative PGAA and NAA results of geological samples and standards

    International Nuclear Information System (INIS)

    Gmeling, K.; Simonits, A.; Sziklai, L.I.; Parkanyi, D.

    2014-01-01

    Concentrations of major and trace elements in volcanic rock and soil samples, including geological standard reference materials, were determined by neutron activation analysis (NAA) and prompt gamma activation analysis (PGAA), both using the k 0-standardization method. The paper highlights the different experimental procedures, such as sample preparation, data collection and spectrum evaluation. In geological samples, PGAA gives precise results for major elements (Si, Ti, Al, Fe, Mn, Mg, Ca, Na, K and - as a unique method - for H), for some of the light trace elements as B and Cl, as well as for Sc, S, Cr, Co, Ni, Cd, Nd, Sm and Gd. NAA is sensitive for the rare earth elements, and for many major (Ti, Al, Fe, Mn, Mg, Ca, Na, K) and trace elements (e.g.: Sc, V, Cr, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Zr, As, Sb, Ce, Ba, Hf, Ta, W). For most major elements the results obtained by the two methods show good agreement. The comparison of the results obtained for trace elements is not always possible, since PGAA is less sensitive and concentrations are often below its detection limits. Nevertheless, the complementarity of NAA and PGAA allows nearly panoramic analysis of geological materials. (author)

  4. Thermal spectrum of pseudo-scalar glueballs and Debye screening mass from holography

    Science.gov (United States)

    Braga, Nelson R. F.; Ferreira, Luiz F.

    2017-10-01

    The finite temperature spectrum of pseudo-scalar glueballs in a plasma is studied using a holographic model. The 0^{-+} glueball is represented by a pseudo-scalar (axion) field living in a five dimensional geometry that comes from a solution of Einstein equations for gravity coupled with a dilaton scalar field. The spectral function obtained from the model shows a clear peak corresponding to the quasi-particle ground state. Analyzing the variation of the position of the peak with temperature, we describe the thermal behavior of the Debye screening mass of the plasma. As a check of consistency, the zero temperature limit of the model is also investigated. The glueball masses obtained are consistent with previous lattice results.

  5. Thermal spectrum of pseudo-scalar glueballs and Debye screening mass from holography

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Nelson R.F.; Ferreira, Luiz F. [Universidade Federal do Rio de Janeiro, Instituto de Fisica, Rio de Janeiro, RJ (Brazil)

    2017-10-15

    The finite temperature spectrum of pseudo-scalar glueballs in a plasma is studied using a holographic model. The 0{sup -+} glueball is represented by a pseudo-scalar (axion) field living in a five dimensional geometry that comes from a solution of Einstein equations for gravity coupled with a dilaton scalar field. The spectral function obtained from the model shows a clear peak corresponding to the quasi-particle ground state. Analyzing the variation of the position of the peak with temperature, we describe the thermal behavior of the Debye screening mass of the plasma. As a check of consistency, the zero temperature limit of the model is also investigated. The glueball masses obtained are consistent with previous lattice results. (orig.)

  6. Size, shape, and diffusivity of a single Debye-Hückel polyelectrolyte chain in solution

    Science.gov (United States)

    Soysa, W. Chamath; Dünweg, B.; Prakash, J. Ravi

    2015-08-01

    Brownian dynamics simulations of a coarse-grained bead-spring chain model, with Debye-Hückel electrostatic interactions between the beads, are used to determine the root-mean-square end-to-end vector, the radius of gyration, and various shape functions (defined in terms of eigenvalues of the radius of gyration tensor) of a weakly charged polyelectrolyte chain in solution, in the limit of low polymer concentration. The long-time diffusivity is calculated from the mean square displacement of the centre of mass of the chain, with hydrodynamic interactions taken into account through the incorporation of the Rotne-Prager-Yamakawa tensor. Simulation results are interpreted in the light of the Odjik, Skolnick, Fixman, Khokhlov, and Khachaturian blob scaling theory (Everaers et al., Eur. Phys. J. E 8, 3 (2002)) which predicts that all solution properties are determined by just two scaling variables—the number of electrostatic blobs X and the reduced Debye screening length, Y. We identify three broad regimes, the ideal chain regime at small values of Y, the blob-pole regime at large values of Y, and the crossover regime at intermediate values of Y, within which the mean size, shape, and diffusivity exhibit characteristic behaviours. In particular, when simulation results are recast in terms of blob scaling variables, universal behaviour independent of the choice of bead-spring chain parameters, and the number of blobs X, is observed in the ideal chain regime and in much of the crossover regime, while the existence of logarithmic corrections to scaling in the blob-pole regime leads to non-universal behaviour.

  7. GIBBS: isothermal-isobaric thermodynamics of solids from energy curves using a quasi-harmonic Debye model

    Science.gov (United States)

    Blanco, M. A.; Francisco, E.; Luaña, V.

    2004-03-01

    Given the energy of a solid ( E) as a function of the molecular volume ( V), the gibbs program uses a quasi-harmonic Debye model to generate the Debye temperature Θ( V), obtains the non-equilibrium Gibbs function G★( V; p, T), and minimizes G★ to derive the thermal equation of state (EOS) V( p, T) and the chemical potential G( p, T) of the corresponding phase. Other macroscopic properties are also derived as a function of p and T from standard thermodynamic relations. The program focuses in obtaining as much thermodynamical information as possible from a minimum set of ( E, V) data, making it suitable to analyse the output of costly electronic structure calculations, adding thermal effects at a low computational cost. Any of three analytical EOS widely used in the literature can be fitted to the p- V( p, T) data, giving an alternative set of isothermal bulk moduli and their pressure derivatives that can be fed to the Debye model machinery. Program summaryTitle of the program:gibbs Catalogue number: ADSY Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADSY Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Licensing provisions: Persons requesting the program must sign the standard CPC non-profit use license Computers on which the program has been tested: Intel Pentium, Alpha, Sun Sparc/Ultra/Blade Operating system under which the program has been tested: Unix, GNU/Linux Programming language used: Fortran 77 Memory required to execute with typical data: 700 KB No. of bits in a word: 32 No. of processors used: 1 No. of bytes in distributed program, including test data, etc.: 277 497 No. of lines in distributed program, including test data, etc.: 7390 Distribution format: tar gzip file Keywords: Quasi-harmonic Debye model, equation of state Nature of physical problem: Derivation of the static and thermal equation of state, chemical potential, and thermodynamic properties of a crystal from energy-volume data only. Method

  8. Preliminary results of standard quantitative analysis by ED-XRF

    International Nuclear Information System (INIS)

    Lara, Alessandro L. de; Franca, Alana C.; Neto, Manoel R.M.; Paschuk, Sergei A.

    2013-01-01

    A comparison between the results of elemental concentration proposed by XRS-FP software , using data obtained by EDXRF technique with those obtained by stoichiometric calculation was performed. For this purpose, five standard samples of known compounds were produced: two lead- oxide, magnesium chloride and iodine in controlled amounts. The compounds were subsequently mixed and compressed to form tablets. The samples were irradiated in three endpoints, according to an orientation. The measurements were performed at the Laboratory for Radiological UTFPR using X-123SDD the Amptek detector and X-ray tube with silver target from the same manufacturer. The operating conditions tube were 05μA current to a 40 kV voltage. Finally, the 15 spectra analyzed with the software to determine the concentration of chlorine, iodine and lead. Data from this analysis were compared with results expected in stoichiometric calculations. The data provided by the program, a convergence of results, indicating homogeneity of the samples was found. Compared to the stoichiometric calculation, a considerable discrepancy that may be the result of a misconfiguration or contamination of the sample was found. At the end, we created a proposal for continuation of the work using an auxiliary calculation should be developed in the next step

  9. The primary extinction and static Debye-Waller factor in the characterization of textured nickel by X-ray diffraction; La extincion primaria y el factor estatico de Debye-Waller en la caracterizacion de niquel con textura mediante difraccion de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Kryshtab, T.; Palacios G, J. [Instituto Politecnico Nacional, Escuela Superior de Fisica y Matematicas, Av. IPN s/n, 07738 Mexico D. F. (Mexico); Cadena A, A. [Instituto Politecnico Nacional, Escuela Superior de Ingenieria Quimica e Industrias Extractivas, Av. IPN s/n, 07738 Mexico D. F. (Mexico); Kryvko, A., E-mail: kryshtab@gmail.com [Instituto Politecnico Nacional, Escuela Superior de Ingenieria Mecanica y Electrica, Unidad Zacatenco, 07360 Mexico D. F. (Mexico)

    2015-07-01

    The texture analysis using X-ray diffraction (XRD) implies measurement of pole figures (Pf) from the diffracted intensities considering the model of kinematical dispersion. The extinction phenomenon results in a decrease of diffracted intensity and that in turn in a decrease of pole densities (Pds). The phenomenon appears in the kinematical theory of XRD as the primary extinction and the secondary extinction to characterize the loss of intensity of kinematical dispersion. In turn, the static Debye-Waller factor is an integral characteristic of defects in crystals that is introduced in the kinematical theory of XRD and also is used in dynamical theory of XRD. In this work the correlation between the primary extinction coefficient and the static Debye-Waller factor in the case of textured nickel was determined. The value of static Debye-Waller factor was determined from the value of the calculated primary extinction coefficient. For the evaluation there were used Pds in the maxima of Pf obtained for 111 and 200 reflections with Mo Kα radiation, and the Pds in the maxima of Pf obtained for the first and second orders of these reflections with Cu Kα and Co Kα radiations. There were calculated the dislocation densities in grains using values of static Debye-Waller factor and the extinction coefficients. The dislocation densities calculated from these two characteristics are practically equal. (Author)

  10. Strength and Debye temperature measurements of cerium across the γ → α volume collapse: the lattice contribution

    International Nuclear Information System (INIS)

    Lipp, M J; Jenei, Zs; Cynn, H; Aracne-Ruddle, C; Evans, W J; Kono, Y; Park, C; Kenney-Benson, C

    2013-01-01

    The longitudinal and transverse sound speeds, c L and c T , of polycrystalline cerium were measured under pressure across the iso-structural γ–α phase transition at 0.75 GPa to beyond 3 GPa. In contrast to previous methods all quantities were directly obtained and no assumptions were made about the size of the volume collapse. Up to the transition our values for c L are in excellent agreement with previous ones, while our values for c T are significantly lower. We deduce values for the adiabatic bulk modulus B S , the shear modulus G=ρc(2)/T, and the pressure dependent Debye temperature, Θ D (p). Θ D (p) is in good agreement with recent results derived from phonon dispersion measurements on single crystals. The ratio of the Debye temperature values bracketing the transition indicates a lattice contribution to the entropy change across the volume collapse, ΔS vib (γ → α) ≈ (0.68 ± 0.06)k B , consistent with previous results obtained by neutron scattering, but significantly larger than other previously determined values. (paper)

  11. An Investigation on the He−(1s2s2 2S Resonance in Debye Plasmas

    Directory of Open Access Journals (Sweden)

    Arijit Ghoshal

    2017-01-01

    Full Text Available The effect of Debye plasma on the 1 s 2 s 2 2 S resonance states in the scattering of electron from helium atom has been investigated within the framework of the stabilization method. The interactions among the charged particles in Debye plasma have been modelled by Debye–Huckel potential. The 1 s 2 s excited state of the helium atom has been treated as consisting of a H e + ionic core plus an electron moving around. The interaction between the core and the electron has then been modelled by a model potential. It has been found that the background plasma environment significantly affects the resonance states. To the best of our knowledge, such an investigation of 1 s 2 s 2 2 S resonance states of the electron–helium system embedded in Debye plasma environment is the first reported in the literature.

  12. X-ray stress measurement of ferritic steel using fourier analysis of Debye-Scherrer ring

    International Nuclear Information System (INIS)

    Fujimoto, Yohei; Sasaki, Toshihiko; Miyazaki, Toshiyuki

    2015-01-01

    In this study, X-ray stress measurements of ferritic steel based on Fourier analysis are conducted. Taira et al. developed the cosα method for X-ray stress measurements using a two-dimensional X-ray detector. Miyazaki et al. reported that the cosα method can be described more concisely by developing the Fourier series (the Fourier analysis method). The Fourier analysis method is expected to yield the stress measurement with an imperfect Debye-Scherrer ring and there is a possibility that the materials evaluation is different compared with the conventional method, that is, the sin 2 ψ method. In the Fourier analysis method, the strain measured by X-rays is developed as a Fourier series, and all the plane-stress components can be calculated from the Fourier series. In this study, the normal stress calculation was confirmed. In addition, the Fourier-analysis and cosα methods were used for X-ray stress measurements during a four-point bending test on a S45C test piece, and the effectiveness of the Fourier analysis method was confirmed. It was found that the experimental results from the Fourier analysis and cosα methods were nearly identical. In addition, the measurement accuracies of both the methods were equivalent. (author)

  13. Interactions of two food colourants with BSA: Analysis by Debye-Hückel theory.

    Science.gov (United States)

    Li, Tian; Cheng, Zhengjun; Cao, Lijun; Jiang, Xiaohui; Fan, Lei

    2016-11-15

    We have focused on exploring pH- and ionic strength-modulated binding of acid red 1 (AR1) and acid green 50 (AG50) with bovine serum albumin (BSA) by fluorescence, UV-vis absorption and FTIR spectra. The results implied that the quenching mechanism of BSA-AR1/AG50 system was a static quenching, electrostatic force dominated the formation of BSA-AR1/AG50 complex, and the binding affinity of AR1 was greater than that of AG50 on the subdomain IIA of BSA. Moreover, their true thermodynamic binding constant (Keq), true free energy change (ΔG(0)I→0), and effective charge (ZP) in the anion receptor pocket of BSA were calculated using Debye-Hückel limiting law. The local charge bound by AR1/AG50 rather than the overall or surface charge of BSA played a key role in determining their interaction strength. Besides, the thermal and structural stabilization of BSA was discussed by analyzing the changes of Tm and Hurea without/with the addition of AR1/AG50, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. X-ray Debye-Waller factor measurements of solid 3He and 4He

    International Nuclear Information System (INIS)

    Arms, D.A.; Shah, R.S.; Simmons, R.O.

    2003-01-01

    X-ray synchrotron radiation was used to measure Debye-Waller factors of helium crystals for both 3 He and 4 He in both hcp and fcc phases. To our knowledge, there are no previous measurements for 3 He. The ranges studied for 3 He and 4 He crystals were 11.52-12.82 and 10.95-12.13 cm 3 , respectively, and 11.5-18.2 and 12.0-20.3 K. With small uncertainty, only a Gaussian dependence upon momentum transfer Q was found, and no anisotropy was detected in the hcp phase. Mean square atomic deviations, 2 >, and Lindemann ratios were obtained. Large Lindemann ratios confirm that these solids are highly anharmonic. The 2 > values agree within an average 1% with computations of Draeger and Ceperley from path integral Monte Carlo methods including unusual extrapolations to the thermodynamic limit. Because the path-integral Monte Carlo (PIMC) computations exhibit a T 3 dependence for 2 >, which also depends upon molar volume, an empirical analysis was made of the present data as well as of published x-ray and neutron data on hcp 4 He. The volume dependencies are similar to those found from calorimetry, over a large volume range, and the temperature dependencies show similar systematic variations with molar volume both in x-ray data and PIMC results

  15. Thermodynamics of Binary Mixed Crystals in the Sub-quasi-chemical/Debye Approximation

    Science.gov (United States)

    van der Kemp, W. J. M.; Verdonk, M. L.

    1995-03-01

    A new statistical model for the description of the thermodynamic properties of binary mixed crystals is discussed. The model is based on an asymmetrical analogue of the quasi-chemical approximation and the Debye model of a solid. With two interchange -energy parameters and two interchange-Debye-temperature parameters, all important thermodynamic functions, at constant volume, of the binary mixed crystal can be calculated as a function of temperature and composition. The binary system {( 1 - x)Nai + xKI}(s) is used for illustration of the model.

  16. A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.

    Science.gov (United States)

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius

    2017-06-01

    The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.

  17. [Neonatal circumcision with local anesthesia. Results of a standardized protocol].

    Science.gov (United States)

    Ovalle, Alejandra; López, Pedro-Jose; Guelfand, Miguel; Zubieta, Ricardo

    2016-01-01

    Neonatal circumcision is a common procedure in the US and other countries, with low rates of complications in trained hands. However, it has recently been incorporated into the clinical environment in Chile. Our goal was to establish a local standardised protocol for neonatal circumcision under local anaesthesia, and evaluate the results and possible complications. A standardised prospective protocol was used on patients who underwent neonatal circumcision. The inclusion criteria were: children local anaesthesia and penile block, attrition of redundant prepuce and mucosa with Mogen® clamp, and section with scalpel. The protocol was used and evaluated from November 2005 to October 2014 by a paediatric surgeon and/or paediatric urologist trained in the technique. Complications and conditions until final discharge were analysed. The protocol was applied to 108 patients over a 9year period. The mean age at procedure was 9days (1-52). One patient (0.9%) had immediate bleeding, requiring further surgery. All patients were discharged from further medical checks at 1 month, without any other complications. The reason for the procedure was by parental request in 100% of the cases, and always for sociocultural reasons. Neonatal circumcision under local anaesthesia is a simple procedure, and has excellent results in selected patients, and with no major complications. With proper training, and adapting the initial protocol, it can be performed on an outpatient basis, without putting the neonates through the risks of general anaesthesia. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Elastic constants and Debye temperature of wz-AlN and wz-GaN ...

    Indian Academy of Sciences (India)

    First-principles calculations were performed to study the elastic stiffness constants ( C i j ) and Debye temperature ( D ) of wurzite (wz) AlN and GaN binary semiconductors at high pressure. The lattice constants were calculated from the optimized structure of these materials. The band gaps were calculated at point using ...

  19. Modelling the X-ray powder diffraction of nitrogen-expanded austenite using the Debye formula

    DEFF Research Database (Denmark)

    Oddershede, Jette; Christiansen, Thomas; Ståhl, Kenny

    2008-01-01

    Stress-free and homogeneous samples of nitrogen-expanded austenite, a defect-rich f.c.c. structure with a high interstitial nitrogen occupancy (between 0.36 and 0.61), have been studied using X-ray powder diffraction and Debye simulations. The simulations confirm the presence of deformation...... to be indistinguishable to X-ray powder diffraction....

  20. Introduction to the theory and application of a unified Bohm criterion for arbitrary-ion-temperature collision-free plasmas with finite Debye lengths

    Science.gov (United States)

    Kos, L.; Jelić, N.; Kuhn, S.; Tskhakaya, D. D.

    2018-04-01

    At present, identifying and characterizing the common plasma-sheath edge (PSE) in the conventional fluid approach leads to intrinsic oversimplifications, while the kinetic one results in unusable over-generalizations. In addition, none of these approaches can be justified in realistic plasmas, i.e., those which are characterized by non-negligible Debye lengths and a well-defined non-negligible ion temperature. In an attempt to resolve this problem, we propose a new formulation of the Bohm criterion [D. Bohm, The Characteristics of Electrical Discharges in Magnetic Fields (McGraw-Hill, New York, 1949)], which is here expressed in terms of fluid, kinetic, and electrostatic-pressure contributions. This "unified" Bohm criterion consists of a set of two equations for calculating the ion directional energy (i.e., the mean directional velocity) and the plasma potential at the common PSE, and is valid for arbitrary ion-to-electron temperature ratios. It turns out to be exact at any point of the quasi-neutral plasma provided that the ion differential polytropic coefficient function (DPCF) of Kuhn et al. [Phys. Plasmas 13, 013503 (2006)] is employed, with the advantage that the DPCF is an easily measurable fluid quantity. Moreover, our unified Bohm criterion holds in plasmas with finite Debye lengths, for which the famous kinetic criterion formulated by Harrison and Thompson [Proc. Phys. Soc. 74, 145 (1959)] fails. Unlike the kinetic criterion in the case of negligible Debye length, the kinetic contribution to the unified Bohm criterion, arising due to the presence of negative and zero velocities in the ion velocity distribution function, can be calculated separately from the fluid term. This kinetic contribution disappears identically at the PSE, yielding strict equality of the ion directional velocity there and the ion sound speed, provided that the latter is formulated in terms of the present definition of DPCFs. The numerical values of these velocities are found for the

  1. Debye series analysis of internal and near-surface fields for a homogeneous sphere illuminated by an axicon-generated vector Bessel beam

    Science.gov (United States)

    Qin, Shitong; Li, Renxian; Yang, Ruiping; Ding, Chunying

    2017-07-01

    The interaction of an axicon-generated vector Bessel beam (AGVBB) with a homogeneous sphere is investigated in the framework of generalized Lorenz-Mie theory (GLMT). An analytical expression of beam shape coefficients (BSCs) is derived using angular spectrum decomposition method (ASDM), and the scattering coefficients are expanded using Debye series (DSE) in order to isolate the contribution of single scattering process. The internal and near-surface electric fields are numerically analyzed, and the effect of beam location, polarization, order of beam, half-cone angle, and scattering process (namely Debye mode p) are mainly discussed. Numerical results show that a curve formed by extreme peaks can be observed, and the electric fields can be locally enhanced after the interaction of AGVBBs with the particle. Internal and near-surface fields, especially its local enhancement, are very sensitive to the beam parameters, including polarization, order, half-cone angle, etc. The internal fields can also be enhanced by various scattering process (or Debye mode p). Such results have important applications in various fields, including particle sizing, optical tweezers, etc.

  2. Corrected Debye-Hückel analysis of surface complexation. II. A theory of surface charging.

    Science.gov (United States)

    Gunnarsson, Magnus; Abbas, Zareen; Ahlberg, Elisabet; Gobom, Sylvia; Nordholm, Sture

    2002-05-01

    A theory of surface charging of colloidal particles suspended in an electrolyte solution is presented. The charging at the particle surface is assumed to originate from the adsorption and desorption of protons and is therefore strongly dependent on the acidity of the solution. The surface binding of protons occurs locally at sites of occupancy zero or one that are described by a binding energy u(0) and a three-dimensional vibration of frequency nu. The diffuse screening of ions at the surface is described by the corrected Debye-Hückel analysis assuming linear response. The model contains a capacitor layer close to the charged surface and the finite size of the electrolyte ions is taken into account. The theory has been applied to titrated surface charge data on goethite (alpha-FeOOH) at NaClO(4) background concentrations ranging from 0.01 to 1.0 M. The protonation mechanism used in the modeling of these data corresponds to the 1-pK approach. A very good description of the experimental data was obtained at the highest ionic strength. Close to the pH(pzc) the theory also gave a good description at lower ionic strengths. However, at low salt concentrations and pH values far away from the pH(pzc) the electrostatic potential outside the capacitor layer becomes so high that nonlinear electrostatic effects become important and the theory therefore underestimates the surface charge. These results were compared with model calculations obtained using existing surface complexation models.

  3. Finite-element time-domain algorithms for modeling linear Debye and Lorentz dielectric dispersions at low frequencies.

    Science.gov (United States)

    Stoykov, Nikolay S; Kuiken, Todd A; Lowery, Madeleine M; Taflove, Allen

    2003-09-01

    We present what we believe to be the first algorithms that use a simple scalar-potential formulation to model linear Debye and Lorentz dielectric dispersions at low frequencies in the context of finite-element time-domain (FETD) numerical solutions of electric potential. The new algorithms, which permit treatment of multiple-pole dielectric relaxations, are based on the auxiliary differential equation method and are unconditionally stable. We validate the algorithms by comparison with the results of a previously reported method based on the Fourier transform. The new algorithms should be useful in calculating the transient response of biological materials subject to impulsive excitation. Potential applications include FETD modeling of electromyography, functional electrical stimulation, defibrillation, and effects of lightning and impulsive electric shock.

  4. Nonabelian Debye screening and the {open_quotes}tsunami{close_quotes} problem

    Energy Technology Data Exchange (ETDEWEB)

    Pisarski, R.D. [Brookhaven National Lab., Upton, NY (United States)

    1997-09-22

    The phenomenon of Debye screening is familiar from electrolytes and many other systems. Recently, it has been recognized that in nonabelian gauge theories at high temperature, even perturbatively Debye screening is much more complicated than in nonrelativistic systems. This was originally derived as {open_quotes}hard thermal loops{close_quotes}. Hard thermal loops have been derived perturbatively, by a semiclassical truncation of the Schwinger-Dyson equations, and by classical kinetic theory. In this talk I give a pedagogical derivation, following that of Kelly, Liu, Lucchesi, and Manuel. The derivation is valid not just for a thermal distribution, but (modulo certain obvious restrictions) for an arbitrary initial distribution of particles. Consider, for example, the {open_quotes}tsunami{close_quotes} problem: suppose that one starts, at time t = 0, with a spatially homogenous, infinite wall of particles, all moving with the same velocity at the speed of light.

  5. Application of Fibonacci oscillators in the Debye model

    Science.gov (United States)

    Marinho, André A. A.; Brito, F. A.; Chesman, C.

    2014-12-01

    In this paper we study the thermodynamics of a crystalline solid by applying q-deformed algebra of Fibonacci oscillators through the generalized Fibonacci sequence of two real and independent deformation parameters q1 and q2. We find a (q1, q2)-deformed Hamiltonian and consequently the q-deformed thermodynamic quantities. The results led us to interpret the deformation parameters acting as disturbance or impurities factors modifying the characteristics of a crystal structure. More specifically, we found the possibility of adjusting the Fibonacci oscillators to describe the change of thermal conductivity of a given element as one inserts impurites.

  6. Temperature dependence of non-Debye disorder in doped manganites

    International Nuclear Information System (INIS)

    Meneghini, C.; Cimino, R.; Pascarelli, S.; Mobilio, S.; Raghu, C.; Sarma, D.D.

    1997-01-01

    Ca-doped manganite La 1-x Ca x MnO 3 samples with x=0.2 and 0.4 were investigated by extended x-ray absorption fine structure (EXAFS) as a function of temperature and preparation method. The samples exhibit characteristic resistivity change across the metal-insulator (MI) transition temperature whose shape and position depend on Ca-doping concentration and sample thermal treatment. EXAFS results evidenced an increase of nonthermal disorder at the MI transition temperature which is significantly correlated with the resistivity behavior. copyright 1997 The American Physical Society

  7. Lattice dynamical appraisal of the anisotropic Debye-Waller factors in graphite lattice

    International Nuclear Information System (INIS)

    Haridasan, T.M.; Sathyamurthy, G.

    1989-12-01

    The Debye-Waller factors in graphite for the atomic motions within the basal plane and also across the basal planes have been calculated using the various lattice dynamical models available to date and a critical comparison is made with the existing experimental data from X ray and neutron scattering studies. The present study reveals the need for further investigation on the nature of atomic motion across the basal planes. (author). 15 refs, 1 tab

  8. Rigorous study of the mean field approximation of Debye and Hueckel for Coulomb systems

    International Nuclear Information System (INIS)

    Kennedy, T.G.

    1984-01-01

    The statistical mechanics of a classical charge symmetric Coulomb system is studied in three dimensions in the limit that the plasma parameter (the inverse temperature divided by the Debye length) goes to zero. To make the system stable, a short range interaction, e.g., hard cores is included. This short range interaction is allowed to go to zero as the plasma parameter goes to zero. Debye and Hueckel used a mean field approximation to give a nonrigorous study of Coulomb systems in his limit. For a system with no external charge distribution, it is shown that the pressure, density, and correlation functions are asymptotic to their Debye-Hueckel approximations. These approximations consist of the ideal gas term plus a term of one lower order in the plasma parameter. The main tools are the Sine-Gordon transformation, the Mayer expansion, and some new correlation inequalities. The sine-Gordon transformation and the Mayer expansion are used to express the observables as functional integrals with respect to a Gaussian measure. The correlation inequalities help control these functional integrals

  9. Peter Debye

    Indian Academy of Sciences (India)

    made much use. Hopefully, the new year will bring more good than our little faith allows us to see at this moment. ... structure to such an extent that the Royal Academy of Sciences has awarded you the Nobel Prize for Chemistry. ... ended in Europe in 1939, during the turmoil of the Second World War. His career as a chemist.

  10. End-Use Opportunity Analysis from Progress Indicator Results for ASHRAE Standard 90.1-2013

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    This report and an accompanying spreadsheet (PNNL 2014a) compile the end use building simulation results for prototype buildings throughout the United States. The results represent he energy use of each edition of ASHRAE Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings (ASHRAE 2004, 2007, 2010, 2013). PNNL examined the simulation results to determine how the remaining energy was used.

  11. Behaviour of TSI in Magnetized Plasmas for different Plasma Oscillation to Debye Wavelength ratio

    Science.gov (United States)

    Jyoti; Malik, Rakhee

    2017-04-01

    The continuity and the momentum equation which take into account the constant rate of ionization are formulated for ions and the electrons. Using normal mode analysis along with linear approximation, potential is found from Poisson’s equation neglecting higher order perturbed terms. From Potential equation, dispersion relation is generated which is solved numerically for obtaining the value of ω using typical plasma parameters. The behavior of growth rate with magnetic field and the propagation angle along with ionization constant has been studied with different plasma oscillation wavelength to Debye length ratio.

  12. First principles and Debye model study of the thermodynamic, electronic and optical properties of MgO under high-temperature and pressure

    Science.gov (United States)

    Miao, Yurun; Li, Huayang; Wang, Hongjuan; He, Kaihua; Wang, Qingbo

    2018-02-01

    First principles and quasi-harmonic Debye model have been used to study the thermodynamic properties, enthalpies, electronic and optical properties of MgO up to the core-mantle boundary (CMB) condition (137 GPa and 3700 K). Thermodynamic properties calculation includes thermal expansion coefficient and capacity, which have been studied up to the CMB pressure (137 GPa) and temperature (3700 K) by the Debye model with generalized gradient approximation (GGA) and local-density approximation (LDA). First principles with hybrid functional method (PBE0) has been used to calculate the electronic and optical properties under pressure up to 137 GPa and 0 K. Our results show the Debye model with LDA and first principles with PBE0 can provide accurate thermodynamic properties, enthalpies, electronic and optical properties. Calculated enthalpies show that MgO keep NaCl (B1) structure up to 137 GPa. And MgO is a direct bandgap insulator with a 7.23 eV calculated bandgap. The bandgap increased with increasing pressure, which will induce a blue shift of optical properties. We also calculated the density of states (DOS) and discussed the relation between DOS and band, optical properties. Equations were used to fit the relations between pressure and bandgaps, absorption coefficient (α(ω)) of MgO. The equations can be used to evaluate pressure after careful calibration. Our calculations can not only be used to identify some geological processes, but also offer a reference to the applications of MgO in the future.

  13. The non-perturbative QCD Debye mass from a Wilson line operator

    CERN Document Server

    Laine, Mikko

    1999-01-01

    According to a proposal by Arnold and Yaffe, the non-perturbative g^2T-contribution to the Debye mass in the deconfined QCD plasma phase can be determined from a single Wilson line operator in the three-dimensional pure SU(3) gauge theory. We extend a previous SU(2) measurement of this quantity to the physical SU(3) case. We find a numerical coefficient which is more accurate and smaller than that obtained previously with another method, but still very large compared with the naive expectation: the correction is larger than the leading term up to T ~ 10^7 T_c, corresponding to g^2 ~ 0.4. At moderate temperatures T ~ 2 T_c, a consistent picture emerges where the Debye mass is m_D ~ 6T, the lightest gauge invariant screening mass in the system is ~ 3T, and the purely magnetic operators couple dominantly to a scale ~ 6T. Electric (~ gT) and magnetic (~ g^2T) scales are therefore strongly overlapping close to the phase transition, and the colour-electric fields play an essential role in the dynamics.

  14. Low temperature thermoelastic properties of galena in a simple, self-consistent, two-term Debye model

    Science.gov (United States)

    Knight, Kevin S.

    2015-03-01

    The thermoelastic properties of the thermoelectric chalcogenide galena, lead sulfide (PbS), have been determined in the temperature interval 10-350 K from high resolution neutron powder diffraction data, and literature values of the isobaric heat capacity. Within this temperature range, galena can be described by a simple phenomenological model in which the cation and anion vibrate independently of one another in a Debye-like manner, with vibrational Debye temperatures of 120(1) K for the lead, and 324(2) K for the sulfur. Simultaneous fitting of the unit cell volume and the isochoric heat capacity to a two-term Debye internal energy function gives characteristic temperatures of 110(2), and 326(5) K in excellent agreement with the measured vibrational Debye temperatures derived from fitting the atomic displacement parameters. The thermodynamic Grüneisen constant derived from the isochoric heat capacity is found to monotonically increase with decreasing temperature, from 2.5 at 300 K, to 3.25 at 25 K, in agreement with the deductions of earlier work. The full phonon density of states calculated from the two-term Debye model shows fair agreement with that derived from density functional theory.

  15. Unprecedented Integral-Free Debye Temperature Formulas: Sample Applications to Heat Capacities of ZnSe and ZnTe

    Directory of Open Access Journals (Sweden)

    R. Pässler

    2017-01-01

    Full Text Available Detailed analytical and numerical analyses are performed for combinations of several complementary sets of measured heat capacities, for ZnSe and ZnTe, from the liquid-helium region up to 600 K. The isochoric (harmonic parts of heat capacities, CVh(T, are described within the frame of a properly devised four-oscillator hybrid model. Additional anharmonicity-related terms are included for comprehensive numerical fittings of the isobaric heat capacities, Cp(T. The contributions of Debye and non-Debye type due to the low-energy acoustical phonon sections are represented here for the first time by unprecedented, integral-free formulas. Indications for weak electronic contributions to the cryogenic heat capacities are found for both materials. A novel analytical framework has been constructed for high-accuracy evaluations of Debye function integrals via a couple of integral-free formulas, consisting of Debye’s conventional low-temperature series expansion in combination with an unprecedented high-temperature series representation for reciprocal values of the Debye function. The zero-temperature limits of Debye temperatures have been detected from published low-temperature Cp(T data sets to be significantly lower than previously estimated, namely, 270 (±3 K for ZnSe and 220 (±2 K for ZnTe. The high-temperature limits of the “true” (harmonic lattice Debye temperatures are found to be 317 K for ZnSe and 262 K for ZnTe.

  16. Two-dimensional imaging of Debye-Scherrer ring for tri-axial stress analysis of industrial materials

    International Nuclear Information System (INIS)

    Sasaki, T; Maruyama, Y; Ohba, H; Ejiri, S

    2014-01-01

    In this study, an application of the two-dimensional imaging technology to the X ray tri-axial stress analysis was studied. An image plate (IP) was used to obtain a Debye-Scherre ring and the image data was analized for determining stress. A new principle for stress analysis which is suitable to two-dimensional imaging data was used. For the verification of this two-dimensional imaging type X-ray stress measurement method, an experiment was conducted using a ferritic steel sample which was processed with a surface grinder. Tri-axial stress analysis was conducted to evaluate the sample. The conventional method for X-ray tri-axial stress analysis proposed by Dölle and Hauk was used to evaluate residual stress in order to compare with the present method. As a result, it was confirmed that a sufficiently highly precise and high-speed stress measurement was enabled with the two-dimensional imaging technology compared with the conventional method

  17. Non-Debye heat capacity formula refined and applied to GaP, GaAs, GaSb, InP, InAs, and InSb

    Directory of Open Access Journals (Sweden)

    R. Pässler

    2013-08-01

    Full Text Available Characteristic non-Debye behaviors of low-temperature heat capacities of GaP, GaAs, GaSb, InP, InAs, and InSb, which are manifested above all in form of non-monotonic behaviors (local maxima of the respective Cp(T/T3 curves in the cryogenic region, are described by means of a refined version of a recently proposed low-to-high-temperature interpolation formula of non-Debye type. Least-mean-square fittings of representative Cp(T data sets available for these materials from several sources show excellent agreements, from the liquid-helium region up to room temperature. The results of detailed calculations of the respective material-specific Debye temperature curves, ΘD(T, are represented in graphical form. The strong, non-monotonic variations of ΘD(T values confirm that it is impossible to provide reasonable numerical simulations of measured Cp(T dependences in terms of fixed Debye temperatures. We show that it is possible to describe in good approximation the complete Debye temperature curves, from the cryogenic region up to their definitive disappearance (dropping to 0 in the high temperature region, by a couple of unprecedented algebraic formulas. The task of constructing physically adequate prolongations of the low-temperature Cp(T curves up to melting points was strongly impeded by partly rather large differences (up to an order of 10 J/(K·mol between the high-temperature data sets presented in different research papers and/or data reviews. Physically plausible criteria are invoked, which enabled an a priori rejection of a series of obviously unrealistic high-temperature data sets. Residual uncertainties for GaAs and InAs could be overcome by re-evaluations of former enthalpy data on the basis of a novel set of properly specified four-parameter polynomial expressions applying to large regions, from moderately low temperatures up to melting points. Detailed analytical and numerical descriptions are given for the anharmonicity

  18. Molecular physics. Production of trilobite Rydberg molecule dimers with kilo-Debye permanent electric dipole moments.

    Science.gov (United States)

    Booth, D; Rittenhouse, S T; Yang, J; Sadeghpour, H R; Shaffer, J P

    2015-04-03

    Permanent electric dipole moments are important for understanding symmetry breaking in molecular physics, control of chemical reactions, and realization of strongly correlated many-body quantum systems. However, large molecular permanent electric dipole moments are challenging to realize experimentally. We report the observation of ultralong-range Rydberg molecules with bond lengths of ~100 nanometers and kilo-Debye permanent electric dipole moments that form when an ultracold ground-state cesium (Cs) atom becomes bound within the electronic cloud of an extended Cs electronic orbit. The electronic character of this hybrid class of "trilobite" molecules is dominated by degenerate Rydberg manifolds, making them difficult to produce by conventional photoassociation. We used detailed coupled-channel calculations to reproduce their properties quantitatively. Our findings may lead to progress in ultracold chemistry and strongly correlated many-body physics. Copyright © 2015, American Association for the Advancement of Science.

  19. A dedicated torsion balance to detect neutrinos by coherent scattering on high Debye temperature monocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Cruceru, I; Nicolescu, G [National Institute of Research and Development for Physics and Nuclear Engineering ' Horia - Hulubei' , PO Box MG - 6, 077125 Magurele (Romania); Duliu, O G [University of Bucharest, Department of Atomic and Nuclear Physics, PO Box MG-II, 077125 Magurele (Romania)

    2008-11-01

    Coherent scattering of neutrinos on high Debye temperature monocrystals represent an alternative to detect solar as well as other high flux neutrino sources such as nuclear reactors or nuclear tests. Therefore, the possibility of detecting neutrinos by using sapphire monocrystals is presented and analyzed. Preliminary evaluations showed that 1 MeV neutrinos with a fluency density of 10{sup 12} cm{sup -1} s{sup -1} could interact with a 100 g sapphire monocrystal with a force of about 10{sup -6} dyne, value measurable with a high sensitivity torsion balance. For this reason a torsion balance provided with 1 m length molybdenum or tungsten wire and an optical autocollimator able to measure small rotation angles of about 0.1 seconds of arc was designed, constructed and now is under preliminary tests. Both theoretical and practical implications of such kind of detector are presented and discussed.

  20. Estimation of the reduction of sputtering for fusion grade materials after disappearance of the Debye sheath

    Science.gov (United States)

    Adhikari, S.; Moulick, R.; Goswami, K. S.

    2018-02-01

    The effect of grazing angle on a solid surface (divertor) erosion due to ion sputtering is studied by 1D-3V fluid approach. For an oblique magnetic field, there exists a region in front of the solid surface called Chodura sheath (CS). It is assumed that the CS is additive to the Debye sheath (DS). For a certain value of the grazing angle, it has been observed that the DS vanishes and the entire potential drop occurs across the CS. This new analysis of the event provides some facts of pragmatic importance in improving the solutions of edge impurity codes. Important factors, such as ion energy, impact angle for physical sputtering are highlighted. The dependence of these two parameters on the grazing angle is also investigated in detail.

  1. KEhD-1 Debye-Sherrar camera with a coordinate proportional counter

    International Nuclear Information System (INIS)

    Ageev, O.I.; Glazova, L.P.; Goganov, D.A.; Rejzis, B.M.; Syrkin, M.G.

    1985-01-01

    An arrangement of the KEhD-1 Debye-Sherrar camera, in which the advantages of a proportional counter are combined with the wide range of simultaneous image recording is described. The camera consists of an X-ray tube unit with the URS-0.1 source, a linear coordinate detector with resistive-capacity coding, a signal transducer and the MK-1 multichannel system for data acquisition and processing based on the ''Uskra-1256'' computer. The counting rate of X-ray pulses is > 5x10 4 s -1 , energy resolution for the CuKsub(α) line constitutes 20%, spatial resolution equals 150 μm, detection efficiency constitutes not less than 64%. The range of the detector displacement varies from -30 deg to +130 deg. The information obtained by means of the camera may be output to a display, a plotter, a numeric printer or a magnetic tape

  2. Accounting for Debye sheath expansion for proud Langmuir probes in magnetic confinement fusion plasmas

    Science.gov (United States)

    Tsui, C. K.; Boedo, J. A.; Stangeby, P. C.; TCV Team

    2018-01-01

    A Child-Langmuir law-based method for accounting for Debye sheath expansion while fitting the current-voltage I-V characteristic of proud Langmuir probes (electrodes that extend into the volume of the plasma) is described. For Langmuir probes of a typical size used in tokamak plasmas, these new estimates of electron temperature and ion saturation current density values decreased by up to 60% compared to methods that did not account for sheath expansion. Changes to the collection area are modeled using the Child-Langmuir law and effective expansion perimeter lp, and the model is thus referred to as the "perimeter sheath expansion method." lp is determined solely from electrode geometry, so the method may be employed without prior measurement of the magnitude of the sheath expansion effects for a given Langmuir probe and can be used for electrodes of different geometries. This method correctly predicts the non-saturating ΔI/ΔV slope for cold, low-density plasmas where sheath-expansion effects are strong, as well as for hot plasmas where ΔI/ΔV ˜ 0, though it is shown that the sheath can still significantly affect the collection area in these hot conditions. The perimeter sheath expansion method has several advantages compared to methods where the non-saturating current is fitted: (1) It is more resilient to scatter in the I-V characteristics observed in turbulent plasmas. (2) It is able to separate the contributions to the ΔI/ΔV slope from sheath expansion to that of the high energy electron tail in high Te conditions. (3) It calculates the change in the collection area due to the Debye sheath for conditions where ΔI/ΔV ˜ 0 and for V = Vf.

  3. The Debye light scattering equation’s scaling relation reveals the purity of synthetic dendrimers

    International Nuclear Information System (INIS)

    Tseng, Hui-Yu; Chen, Hsiao-Ping; Tang, Yi-Hsuan; Chen, Hui-Ting; Kao, Chai-Lin; Wang, Shau-Chun

    2016-01-01

    Spherical dendrimer structures cannot be structurally modeled using conventional polymer models of random coil or rod-like configurations during the calibration of the static light scattering (LS) detectors used to determine the molecular weight (M.W.) of a dendrimer or directly assess the purity of a synthetic compound. In this paper, we used the Debye equation-based scaling relation, which predicts that the static LS intensity per unit concentration is linearly proportional to the M.W. of a synthetic dendrimer in a dilute solution, as a tool to examine the purity of high-generational compounds and to monitor the progress of dendrimer preparations. Without using expensive equipment, such as nuclear magnetic resonance or mass spectrometry, this method only required an affordable flow injection set-up with an LS detector. Solutions of the purified dendrimers, including the poly(amidoamine) (PAMAM) dendrimer and its fourth to seventh generation pyridine derivatives with size range of 5–9 nm, were used to establish the scaling relation with high linearity. The use of artificially impure mixtures of six or seven generations revealed significant deviations from linearity. The raw synthesized products of the pyridine-modified PAMAM dendrimer, which included incompletely reacted dendrimers, were also examined to gauge the reaction progress. As a reaction toward a particular generational derivative of the PAMAM dendrimers proceeded over time, deviations from the linear scaling relation decreased. The difference between the polydispersity index of the incompletely converted products and that of the pure compounds was only about 0.01. The use of the Debye equation-based scaling relation, therefore, is much more useful than the polydispersity index for monitoring conversion processes toward an indicated functionality number in a given preparation.Graphical abstract

  4. The Debye light scattering equation’s scaling relation reveals the purity of synthetic dendrimers

    Energy Technology Data Exchange (ETDEWEB)

    Tseng, Hui-Yu; Chen, Hsiao-Ping [National Chung Cheng University, Department of Chemistry and Biochemistry (China); Tang, Yi-Hsuan [Kaohsiung Medical University, Department of Medicinal and Applied Chemistry (China); Chen, Hui-Ting [Kaohsiung Medical University, Department of Fragrance and Cosmetic Science (China); Kao, Chai-Lin, E-mail: clkao@kmu.edu.tw [Kaohsiung Medical University, Department of Medicinal and Applied Chemistry (China); Wang, Shau-Chun, E-mail: chescw@ccu.edu.tw [National Chung Cheng University, Department of Chemistry and Biochemistry (China)

    2016-03-15

    Spherical dendrimer structures cannot be structurally modeled using conventional polymer models of random coil or rod-like configurations during the calibration of the static light scattering (LS) detectors used to determine the molecular weight (M.W.) of a dendrimer or directly assess the purity of a synthetic compound. In this paper, we used the Debye equation-based scaling relation, which predicts that the static LS intensity per unit concentration is linearly proportional to the M.W. of a synthetic dendrimer in a dilute solution, as a tool to examine the purity of high-generational compounds and to monitor the progress of dendrimer preparations. Without using expensive equipment, such as nuclear magnetic resonance or mass spectrometry, this method only required an affordable flow injection set-up with an LS detector. Solutions of the purified dendrimers, including the poly(amidoamine) (PAMAM) dendrimer and its fourth to seventh generation pyridine derivatives with size range of 5–9 nm, were used to establish the scaling relation with high linearity. The use of artificially impure mixtures of six or seven generations revealed significant deviations from linearity. The raw synthesized products of the pyridine-modified PAMAM dendrimer, which included incompletely reacted dendrimers, were also examined to gauge the reaction progress. As a reaction toward a particular generational derivative of the PAMAM dendrimers proceeded over time, deviations from the linear scaling relation decreased. The difference between the polydispersity index of the incompletely converted products and that of the pure compounds was only about 0.01. The use of the Debye equation-based scaling relation, therefore, is much more useful than the polydispersity index for monitoring conversion processes toward an indicated functionality number in a given preparation.Graphical abstract.

  5. Accounting for Debye sheath expansion for proud Langmuir probes in magnetic confinement fusion plasmas.

    Science.gov (United States)

    Tsui, C K; Boedo, J A; Stangeby, P C

    2018-01-01

    A Child-Langmuir law-based method for accounting for Debye sheath expansion while fitting the current-voltage I-V characteristic of proud Langmuir probes (electrodes that extend into the volume of the plasma) is described. For Langmuir probes of a typical size used in tokamak plasmas, these new estimates of electron temperature and ion saturation current density values decreased by up to 60% compared to methods that did not account for sheath expansion. Changes to the collection area are modeled using the Child-Langmuir law and effective expansion perimeter l p , and the model is thus referred to as the "perimeter sheath expansion method." l p is determined solely from electrode geometry, so the method may be employed without prior measurement of the magnitude of the sheath expansion effects for a given Langmuir probe and can be used for electrodes of different geometries. This method correctly predicts the non-saturating ΔI/ΔV slope for cold, low-density plasmas where sheath-expansion effects are strong, as well as for hot plasmas where ΔI/ΔV ∼ 0, though it is shown that the sheath can still significantly affect the collection area in these hot conditions. The perimeter sheath expansion method has several advantages compared to methods where the non-saturating current is fitted: (1) It is more resilient to scatter in the I-V characteristics observed in turbulent plasmas. (2) It is able to separate the contributions to the ΔI/ΔV slope from sheath expansion to that of the high energy electron tail in high Te conditions. (3) It calculates the change in the collection area due to the Debye sheath for conditions where ΔI/ΔV ∼ 0 and for V = V f .

  6. Information-theoretic measures of hydrogen-like ions in weakly coupled Debye plasmas

    Science.gov (United States)

    Zan, Li Rong; Jiao, Li Guang; Ma, Jia; Ho, Yew Kam

    2017-12-01

    Recent development of information theory provides researchers an alternative and useful tool to quantitatively investigate the variation of the electronic structure when atoms interact with the external environment. In this work, we make systematic studies on the information-theoretic measures for hydrogen-like ions immersed in weakly coupled plasmas modeled by Debye-Hückel potential. Shannon entropy, Fisher information, and Fisher-Shannon complexity in both position and momentum spaces are quantified in high accuracy for the hydrogen atom in a large number of stationary states. The plasma screening effect on embedded atoms can significantly affect the electronic density distributions, in both conjugate spaces, and it is quantified by the variation of information quantities. It is shown that the composite quantities (the Shannon entropy sum and the Fisher information product in combined spaces and Fisher-Shannon complexity in individual space) give a more comprehensive description of the atomic structure information than single ones. The nodes of wave functions play a significant role in the changes of composite information quantities caused by plasmas. With the continuously increasing screening strength, all composite quantities in circular states increase monotonously, while in higher-lying excited states where nodal structures exist, they first decrease to a minimum and then increase rapidly before the bound state approaches the continuum limit. The minimum represents the most reduction of uncertainty properties of the atom in plasmas. The lower bounds for the uncertainty product of the system based on composite information quantities are discussed. Our research presents a comprehensive survey in the investigation of information-theoretic measures for simple atoms embedded in Debye model plasmas.

  7. Debye potentials, electromagnetic reciprocity and impedance boundary conditions for efficient analytic approximation of coupling impedances in complex heterogeneous accelerator pipes

    Energy Technology Data Exchange (ETDEWEB)

    Petracca, S. [Salerno Univ. (Italy)

    1996-08-01

    Debye potentials, the Lorentz reciprocity theorem, and (extended) Leontovich boundary conditions can be used to obtain simple and accurate analytic estimates of the longitudinal and transverse coupling impedances of (piecewise longitudinally uniform) multi-layered pipes with non simple transverse geometry and/or (spatially inhomogeneous) boundary conditions. (author)

  8. Non-SUSY Beyond Standard Model Searches: Recent Results from ATLAS and CMS

    CERN Document Server

    Malek, Fairouz; The ATLAS collaboration

    2015-01-01

    The Standard Model of particle physics is a sensational success, especially since the discovery of the 125 GeV Higgs boson. However, there are still numerous unanswered questions. Why is the Higgs so light? Do the interactions couplings unify and how can gravity be included? Why three fermion generations? What is dark matter? Theories Beyond the Standard Model (BSM), such as Grand Unified Theories, Extra Dimensions or Technicolour are trying to answer these questions. In this proceedings, we will focus on the most recent results obtained by the ATLAS and CMS experiments at the LHC for BSM searches, excluding Higgs and supersymmetry searches. New results on Dark matter, heavy narrow bosons, new heavy quarks and third generation leptoquarks are presented. A summary of the prospects at 14 TeV and at the High Luminosity LHC period is given.

  9. Calibration and consistency of results of an ionization-chamber secondary standard measuring system for activity

    International Nuclear Information System (INIS)

    Schrader, Heinrich

    2000-01-01

    Calibration in terms of activity of the ionization-chamber secondary standard measuring systems at the PTB is described. The measurement results of a Centronic IG12/A20, a Vinten ISOCAL IV and a radionuclide calibrator chamber for nuclear medicine applications are discussed, their energy-dependent efficiency curves established and the consistency checked using recently evaluated radionuclide decay data. Criteria for evaluating and transferring calibration factors (or efficiencies) are given

  10. Evaluation of a draft standard on performance specifications for health physics instrumentation: results for environmental tests

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Mashburn, K.R.; Selby, J.M.

    1984-06-01

    Draft ANSI Standard N42.17 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. Evaluation is performed by testing a cross-section of currently available instruments with testing procedures based on specifications of the standard and then determining the degree of conformance to the various elements of the proposed standard. Data will be presented on the performance of a cross-section of beta-gamma survey instruments under various environmental tests. Test results that will be presented include temperature effects, humidity effects, radio frequency (r.f.) susceptibility, ambient pressure effects, vibration effects, and shock effects. Tests performed to date show that most instruments will meet the temperature, humidity, and ambient pressure tests. A large variability is noted among instruments from the same or different vendors. Preliminary r.f. susceptibility tests have shown large artificial responses at some frequencies for specific instruments. The presentation will also include a discussion of procedures used in the testing and weaknesses identified in the proposed standard

  11. Validation Test For The Result Of Neutron Activation Analysis With Standard Reference Material

    International Nuclear Information System (INIS)

    Rina M, Th; Wardani, Sri

    2001-01-01

    The validity test with standard reference material is necessary to ensure the result analysis of samples. The analysis of CRM No.8 (Vehicle Exhaust Particulates) and SRM 1646a (Estuary Sediment) has been done in P2TRR. These analysis is intended to validate the analysis result done in NAA laboratory of P2TRR. For the CRM No. 8, is elements of the 30 certified elements were successfully analyzed Meanwhile, for SRM 1646a, 21 elements of the 39 certified elements were completely investigated The quantitative analysis showed the relative difference of 2% - 15% compared to the certificate

  12. Stability results of a free air ionization chamber in standard mammography beams

    International Nuclear Information System (INIS)

    Silva, Natalia F.; Xavier, Marcos; Vivolo, Vitor; Caldas, Linda V.E.

    2015-01-01

    Free air ionization chambers are absolute dosimeters, because they can measure basic physical quantities directly without the need of their calibration in a standard radiation beam. They are used for measuring exposure and air kerma in X and gamma radiation beams. The Calibration Laboratory (LCI) of IPEN has a free air ionization chamber of the cylindrical type for low energies. The characterization of this ionization chamber was already performed and reported in a previous study. After a modification in the support of the micrometers used for the movement of the internal cylinder devices, the tests were redone. The objective of this work was to present the new alignment protocol of the free air ionization chamber in low energies of X-ray beams of standard mammography qualities, assuring the positioning reproducibility, and new results of stability tests performed with the application of this protocol will be presented. (author)

  13. Thermal noise due to surface-charge effects within the Debye layer of endogenous structures in dendrites

    Science.gov (United States)

    Poznanski, Roman R.

    2010-02-01

    An assumption commonly used in cable theory is revised by taking into account electrical amplification due to intracellular capacitive effects in passive dendritic cables. A generalized cable equation for a cylindrical volume representation of a dendritic segment is derived from Maxwell’s equations under assumptions: (i) the electric-field polarization is restricted longitudinally along the cable length; (ii) extracellular isopotentiality; (iii) quasielectrostatic conditions; and (iv) homogeneous medium with constant conductivity and permittivity. The generalized cable equation is identical to Barenblatt’s equation arising in the theory of infiltration in fissured strata with a known analytical solution expressed in terms of a definite integral involving a modified Bessel function and the solution to a linear one-dimensional classical cable equation. Its solution is used to determine the impact of thermal noise on voltage attenuation with distance at any particular time. A regular perturbation expansion for the membrane potential about the linear one-dimensional classical cable equation solution is derived in terms of a Green’s function in order to describe the dynamics of free charge within the Debye layer of endogenous structures in passive dendritic cables. The asymptotic value of the first perturbative term is explicitly evaluated for small values of time to predict how the slowly fluctuating (in submillisecond range) electric field attributed to intracellular capacitive effects alters the amplitude of the membrane potential. It was found that capacitive effects are almost negligible for cables with electrotonic lengths L>0.5 , contributes up to 10% of the signal for cables with electrotonic lengths in the range between 0.25results show that electrotonically short dendritic cables with both ends sealed are prone to significant neurobiological thermal noise due

  14. Comparison of complications and functional results of standard posterolateral thoracotomy with muscle sparing thoracotomy

    Directory of Open Access Journals (Sweden)

    Peiravy Sereshke H

    2009-10-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Standard thoracotomy necessitates division of thoracic large muscles leading to pain and impaired respiratory movements; muscle sparing postero-lateral thoracotomy has been suggested as an alternative to reduce the aforementioned effect. The aim of this study was to compare muscle saving posterolateral thoracotomy with standard thoracotomy."n"nMethods: This study was a clinical trial. All patients who were candidates for elective thoracotomy were included and divided into two groups of muscle saving thoracotomy and standard thoracotomy randomly. Required time for opening and closing the chest, amount of prescribed narcotics, shoulder movements (flexion, extension, abduction and internal rotation, pulmonary function (FVC, FEV1, VC, development of seroma, and duration of hospitalization were assessed. Shoulder movements and pulmonary function were measured immediately before operation and 7 days later while pain measured in 1st and 7th post-operative days."n"nResults: 60 patients (42 males entered the study and there were no significant differences regarding age and sex distribution between two groups (p>0.05. Mean duration of opening the chest in muscle saving thoracotomy was significantly longer than

  15. Is It Working? Distractor Analysis Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-05-01

    The Test Of Astronomy STandards (TOAST) assessment instrument is a multiple-choice survey tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) have been conducting a question-by-question distractor analysis procedure to determine the sensitivity and effectiveness of each item. In brief, the frequency each possible answer choice, known as a foil or distractor on a multiple-choice test, is determined and compared to the existing literature on the teaching and learning of astronomy. In addition to having statistical difficulty and discrimination values, a well functioning assessment item will show students selecting distractors in the relative proportions to how we expect them to respond based on known misconceptions and reasoning difficulties. In all cases, our distractor analysis suggests that all items are functioning as expected. These results add weight to the validity of the Test Of Astronomy STandards (TOAST) assessment instrument, which is designed to help instructors and researchers measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  16. Limits of metastability in amorphous ices: the neutron scattering Debye-Waller factor.

    Science.gov (United States)

    Amann-Winkel, Katrin; Löw, Florian; Handle, Philip H; Knoll, Wiebke; Peters, Judith; Geil, Burkhard; Fujara, Franz; Loerting, Thomas

    2012-12-21

    Recently, it became clear that relaxation effects in amorphous ices play a very important role that has previously been overlooked. The thermodynamic history of amorphous samples strongly affects their transition behavior. In particular, well-relaxed samples show higher thermal stability, thereby providing a larger window to investigate their glass transitions. We here present neutron scattering experiments using fixed elastic window scans on relaxed forms of amorphous ice, namely expanded high density amorphous ice (eHDA), a variant of low density amorphous ice (LDA-II) and hyperquenched glassy water (HGW). These amorphous ices are expected to be true glassy counterparts of deeply supercooled liquid water, therefore fast precursor dynamics of structural relaxation are expected to appear below the calorimetric glass transition temperature. The Debye-Waller factor shows a very weak sub-T(g) anomaly in some of the samples, which might be the signature of such fast precursor dynamics. However, we cannot find this behavior consistently in all samples at all reciprocal length scales of momentum transfer.

  17. Recent results of searches for beyond Standard Model physics in ATLAS

    CERN Document Server

    Serkin, Leonid; The ATLAS collaboration

    2017-01-01

    Recent results of searches for beyond Standard Model physics in ATLAS are presented, with particular focus on searches for new phenomena in high jet multiplicity final states. These include searches for charged Higgs boson in the $H^{+} \\to tb $ decay channel, vector-like quark pair production, four-top-quark production in different signal benchmark scenarios and associated heavy Higgs boson production. No significant excess are observed in data and exclusion limits on cross sections and masses are given for the signal models in a number of benchmark scenarios, in most cases significantly extending the reach of previous searches.

  18. Results from the direct search for the Standard Model Higgs boson at LEP

    CERN Document Server

    Marco, Jesus

    2001-01-01

    The direct search for the Standard Model Higgs boson at LEP, using 2.5 fb−1 of e+e− collision data collected and analyzed by the four LEP collaborations, ALEPH, DELPHI, L3 and OPAL, at center-of-mass energies between 189 and 209 GeV, is pre- sented. The combination of their results by the LEP Higgs Working Group sets a lower bound for the SM Higgs boson mass of 114.1 GeV/c2 at the 95% confidence level. The excess observed in the higher mass zone, with a significance at the 2 σ level, is described.

  19. The influence of motivations and other factors on the results of implementing ISO 9001 standards

    Directory of Open Access Journals (Sweden)

    Carlos del Castillo-Peces

    2018-01-01

    Full Text Available The objective of this paper is to analyze the influence that the internal and external motivations, as well as other factors can suppose for the appearance of the benefits derived from the adherence to the ISO 9001 Standards. For this, it has been made a research centered in The Spanish construction sector. This sector is of great importance at both the global and Spanish level, and ISO 9001 Standard is widespread in it. A questionnaire was sent to 302 companies that are part of this sector, obtaining 126 valid questionnaires, whose data have been treated using a multiple linear regression model. The results of this model indicate that the type of internal or external motivation to implement such a regulation, as well as the seniority in adhering to it, are significant variables for the achievement of the positive results that can be derived from ISO 9001. However, the size of the company is not significant for the appearance of such results.

  20. Standardized modified colposuspension – mid-term results of prospective studies in one centre

    Directory of Open Access Journals (Sweden)

    Grzegorz Surkont

    2015-05-01

    Full Text Available Introduction. Burch colposuspension is still estimated as a ‘gold standard’ by the Cochrane Collaboration Group in the treatment of operative stress urinary incontinence (SUI Some urogynecologists agree with this statement, some argue that Burch colposuspension should no longer be used. Objective. The aim of this study was to evaluate mid-term effects and patient’s satisfaction with standardized modified colposuspension performed in one centre. Material and methods. Modified colposuspension was performed after standardization by 2 trained gynaecologists in 354 women. Data collected from 227 women were added to the final analysis of mid-term results. Average time from the operation to mid-term visit was 19 months (range 9–36 months. Results. At mid-term visit, 86.3% of patients were cured. There was no case of post-void urine residual over 100 ml. Pain near the operated region was reported by 1 woman from agricultural region. No one reported negative impact of modified colposuspension on sexual activity or dyspareunia. Conclusions. Modified colposuspension according to the E. Petri technique seems to be an operation that is safe and well-tolerated by women with preoperative stress urinary incontinence and paravaginal defect without urodynamic signs of ISD in mid-term observation.

  1. Collisional scattering for binary Coulomb interactions that are cut off at a distance different than the Debye length

    International Nuclear Information System (INIS)

    Correa, J.R.; Chang Yongbin; Ordonez, C.A.

    2005-01-01

    Collisional scattering is considered within a system of charged particles experiencing binary Coulomb interactions when the scale length for the range of each interaction is not isotropic and is not necessarily equal to the Debye length. For example, one or more dimensions of the system could be smaller than the Debye length. The effect is assessed by evaluating integrals over the impact cross section. Cutoffs on both the impact parameter and the Coulomb interaction potential are employed, and no assumption is made regarding the value of the Coulomb logarithm. Two expressions are found that have a dependence on the cutoff lengths, with one of the expressions being associated with the Coulomb logarithm. Collisional scattering within an electrostatic ion trap is considered by way of example

  2. Inelastic dark matter, non-standard halos and the DAMA/LIBRA results

    International Nuclear Information System (INIS)

    March-Russell, John; McCabe, Christopher; McCullough, Matthew

    2009-01-01

    The DAMA collaboration have claimed to detect particle dark matter (DM) via an annual modulation in their observed recoil event rate. This appears to be in strong disagreement with the null results of other experiments if interpreted in terms of elastic DM scattering, while agreement for a small region of parameter space is possible for inelastic DM (iDM) due to the altered kinematics of the collision. To date most analyses assume a simple galactic halo DM velocity distribution, the Standard Halo Model, but direct experimental support for the SHM is severely lacking and theoretical studies indicate possible significant differences. We investigate the dependence of DAMA and the other direct detection experiments on the local DM velocity distribution, utilizing the results of the Via Lactea and Dark Disc numerical simulations. We also investigate effects of varying the solar circular velocity, the DM escape velocity, and the DAMA quenching factor within experimental limits. Our data set includes the latest ZEPLIN-III results, as well as full publicly available data sets. Due to the more sensitive dependence of the inelastic cross section on the velocity distribution, we find that with Via Lactea the DAMA results can be consistent with all other experiments over an enlarged region of iDM parameter space, with higher mass particles being preferred, while Dark Disc does not lead to an improvement. A definitive test of DAMA for iDM requires heavy element detectors.

  3. Standardization of reflectance measurements in dispersed organic matter: results of an exercise to improve interlaboratory agreement

    Science.gov (United States)

    Hackley, Paul C.; Araujo, Carla Viviane; Borrego, Angeles G.; Bouzinos, Antonis; Cardott, Brian; Cook, Alan C.; Eble, Cortland; Flores, Deolinda; Gentzis, Thomas; Gonçalves, Paula Alexandra; Filho, João Graciano Mendonça; Hámor-Vidó, Mária; Jelonek, Iwona; Kommeren, Kees; Knowles, Wayne; Kus, Jolanta; Mastalerz, Maria; Menezes, Taíssa Rêgo; Newman, Jane; Pawlewicz, Mark; Pickel, Walter; Potter, Judith; Ranasinghe, Paddy; Read, Harold; Reyes, Julito; Rodriguez, Genaro De La Rosa; de Souza, Igor Viegas Alves Fernandes; Suarez-Ruiz, Isabel; Sýkorová, Ivana; Valentine, Brett J.

    2015-01-01

    Vitrinite reflectance generally is considered the most robust thermal maturity parameter available for application to hydrocarbon exploration and petroleum system evaluation. However, until 2011 there was no standardized methodology available to provide guidelines for vitrinite reflectance measurements in shale. Efforts to correct this deficiency resulted in publication of ASTM D7708: Standard test method for microscopical determination of the reflectance of vitrinite dispersed in sedimentary rocks. In 2012-2013, an interlaboratory exercise was conducted to establish precision limits for the D7708 measurement technique. Six samples, representing a wide variety of shale, were tested in duplicate by 28 analysts in 22 laboratories from 14 countries. Samples ranged from immature to overmature (0.31-1.53% Ro), from organic-lean to organic-rich (1-22 wt.% total organic carbon), and contained Type I (lacustrine), Type II (marine), and Type III (terrestrial) kerogens. Repeatability limits (maximum difference between valid repetitive results from same operator, same conditions) ranged from 0.03-0.11% absolute reflectance, whereas reproducibility limits (maximum difference between valid results obtained on same test material by different operators, different laboratories) ranged from 0.12-0.54% absolute reflectance. Repeatability and reproducibility limits degraded consistently with increasing maturity and decreasing organic content. However, samples with terrestrial kerogens (Type III) fell off this trend, showing improved levels of reproducibility due to higher vitrinite content and improved ease of identification. Operators did not consistently meet the reporting requirements of the test method, indicating that a common reporting template is required to improve data quality. The most difficult problem encountered was the petrographic distinction of solid bitumens and low-reflecting inert macerals from vitrinite when vitrinite occurred with reflectance ranges overlapping

  4. Scoliosis short-term rehabilitation (SSTR according to 'Best Practice' standards - are the results repeatable?

    Directory of Open Access Journals (Sweden)

    Borysov Maksym

    2012-01-01

    Full Text Available Abstract Claims have been made in a pilot study that a new form of short-term rehabilitation according to 'Best Practice' standards would change signs and symptoms of patients with scoliosis in the short-term. Aim of this study is to repeat the study published 2010 with a larger sample of patients using the same protocol. Both authors have undergone training in this special approach to scoliosis rehabilitation in 2010. Materials and methods 34 patients with Adolescent Idiopathic Scoliosis (AIS, 32 girls and 2 boys, average age 13.7 years and an average Cobb angle of 28.7 degrees (21-43 degrees underwent Scoliosis Short-Term Rehabilitation (SSTR of seven days. Two days with an intensity of 3 × 90 min sessions/day, and five days with an intensity of 2 × 60 min sessions/day. Angle of trunk rotation (ATR was measured before and after the time of treatment as well as the active correctability of the ATR after the programme as it has been done in the pilot investigation. Additionally to that, we also recorded the changes in Vital Capacity (VC before and after the programme. Results ATR was reduced significantly from 11,5 degrees to 8,4 degrees, the active correctability as measured with the Scoliometer (TM was also reduced significantly from the ATR after treatment 8,9 degrees to 6,5 degrees in the patients with thoracic curves. VC improved significantly (P Discussion The results achieved in the pilot investigation published previously are repeatable. The deformity of the trunk can be reduced significantly after SSTR. During the pilot study VC was not investigated. In our study VC improved significantly. Therefore, also shorter rehabilitation times with an appropriate programme seem to be able to change signs and symptoms of a patient with scoliosis. Like the out-patient Schroth programme as described in a study from Turkey, the SSTR provides benefits leading to an improvement of the condition. Conclusion Out-patient rehabilitation following the

  5. Results of patch testing with a standard series of allergens at Manipal

    Directory of Open Access Journals (Sweden)

    Shenoi Shrutakirthi

    1994-01-01

    Full Text Available The study was designed to determine the common sensitizers in allergic contact dermatitis, to evolve a standard patch test tray for screening patients at our centre and to suggest allergens for multicentric trial in India. 212 patients (65 women, 147 men were patch tested with a standard series of allergens (23 allergens of European standard series extended with lanolin, cresol and gentamycin. The frequent sensitizers observed were gentamycin (14.2%, potassium dichromate (7.1%, colophony (6.6% and fragrance mix (6.1%. No positive reactions were observed for lanolin, quaternium - 15 and mercaptomix. Our standard tray will thus consist of all the allergens of European standard series except primin along with lanolin, cresol and gentamycin. Lanolin is included despite negativity as it was found to be the commonest sensitizer among topical medications in our previous study.

  6. Result of standard patch test in patients suspected of having allergic contact dermatitis.

    Science.gov (United States)

    Wongpiyabovorn, Jongkonnee; Puvabanditsin, Porntip

    2005-09-01

    Contact dermatitis is a common skin disease. Disease was diagnosed by a history of contact substance together with geographic distribution of lesion. Up till now, standard patch test is one of the most reliable test to identify and confirm causative agent of allergic contact dermatitis. To determine the rate of positive standard patch test and to identify the common allergen of contact dermatitis in Thailand, we performed the standard patch test in 129 patients, suspected having allergic contact dermatitis at Department of Dermatology, King Chulalongkorn Memorial Hospital, Thailand from June 1, 2003 to September 1, 2004. The rate of positive standard patch test is 59.7% (n = 77/129). The most 3 common positive allergens were nickel sulfate (18.60%), cobalt chloride (17.05%) and fragrance mix (14.73%), respectively. The chance of positive standard patch test significantly correlated with sex (woman), initial diagnosis as contact dermatitis and history of house-worker (p = 0.017, p = 0.005 and p = 0.023, respectively). Whereas, there were no significant correlation between the chance of positive standard patch test and age of patient, location of lesion, history of recurrence, history of atopy, history of drug and food allergy. In addition, history of metal allergy significantly correlated with the chance of positive nickel sulfate or cobalt chloride in standard patch test (p = 0.017). In conclusion, this study demonstrated the prevalence of causative allergen of contact dermatitis in Thai patients using that standard patch test. Moreover, our data shown that the chance positive standard patch test was greater in patient, who were women or initial diagnosed as contact dermatitis or had history of houseworker or history of metal allergy.

  7. Results of international standard problem No. 36 severe fuel damage experiment of a VVER fuel bundle

    Energy Technology Data Exchange (ETDEWEB)

    Firnhaber, M. [Gesellschaft fuer Anlagen-und Reaktorsicherheit, Koeln (Germany); Yegorova, L. [Nuclear Safety Institute of Russian Research Center, Moscow (Russian Federation); Brockmeier, U. [Ruhr-Univ. of Bochum (Germany)] [and others

    1995-09-01

    International Standard Problems (ISP) organized by the OECD are defined as comparative exercises in which predictions with different computer codes for a given physical problem are compared with each other and with a carefully controlled experimental study. The main goal of ISP is to increase confidence in the validity and accuracy of analytical tools used in assessing the safety of nuclear installations. In addition, it enables the code user to gain experience and to improve his competence. This paper presents the results and assessment of ISP No. 36, which deals with the early core degradation phase during an unmitigated severe LWR accident in a Russian type VVER. Representatives of 17 organizations participated in the ISP using the codes ATHLET-CD, ICARE2, KESS-III, MELCOR, SCDAP/RELAP5 and RAPTA. Some participants performed several calculations with different codes. As experimental basis the severe fuel damage experiment CORA-W2 was selected. The main phenomena investigated are thermal behavior of fuel rods, onset of temperature escalation, material behavior and hydrogen generation. In general, the calculations give the right tendency of the experimental results for the thermal behavior, the hydrogen generation and, partly, for the material behavior. However, some calculations deviate in important quantities - e.g. some material behavior data - showing remarkable discrepancies between each other and from the experiments. The temperature history of the bundle up to the beginning of significant oxidation was calculated quite well. Deviations seem to be related to the overall heat balance. Since the material behavior of the bundle is to a great extent influenced by the cladding failure criteria a more realistic cladding failure model should be developed at least for the detailed, mechanistic codes. Regarding the material behavior and flow blockage some models for the material interaction as well as for relocation and refreezing requires further improvement.

  8. Comparison between Einstein and Debye models for an amorphous Ni46Ti54 alloy produced by mechanical alloying investigated using extended x-ray absorption fine structure and cumulant expansion.

    Science.gov (United States)

    Machado, K D

    2011-02-14

    We investigated an amorphous Ni(46)Ti(54) alloy produced by mechanical alloying using extended x-ray absorption fine structure (EXAFS) technique and cumulant expansion considering Einstein and Debye models for the temperature dependence of the cumulants. Results obtained from both models were compared and very similar values were obtained. From them, we found information about the structure of the alloy besides thermal and structural disorder, anharmonicity, thermal expansion, and asymmetry of the partial distribution functions g(ij)(r). The cumulants C(1)(*), C(2)(*), and C(3)(*) also allowed us to reconstruct the g(ij)(r, T) functions from EXAFS.

  9. Towards reporting standards for neuropsychological study results: A proposal to minimize communication errors with standardized qualitative descriptors for normalized test scores.

    Science.gov (United States)

    Schoenberg, Mike R; Rum, Ruba S

    2017-11-01

    Rapid, clear and efficient communication of neuropsychological results is essential to benefit patient care. Errors in communication are a lead cause of medical errors; nevertheless, there remains a lack of consistency in how neuropsychological scores are communicated. A major limitation in the communication of neuropsychological results is the inconsistent use of qualitative descriptors for standardized test scores and the use of vague terminology. PubMed search from 1 Jan 2007 to 1 Aug 2016 to identify guidelines or consensus statements for the description and reporting of qualitative terms to communicate neuropsychological test scores was conducted. The review found the use of confusing and overlapping terms to describe various ranges of percentile standardized test scores. In response, we propose a simplified set of qualitative descriptors for normalized test scores (Q-Simple) as a means to reduce errors in communicating test results. The Q-Simple qualitative terms are: 'very superior', 'superior', 'high average', 'average', 'low average', 'borderline' and 'abnormal/impaired'. A case example illustrates the proposed Q-Simple qualitative classification system to communicate neuropsychological results for neurosurgical planning. The Q-Simple qualitative descriptor system is aimed as a means to improve and standardize communication of standardized neuropsychological test scores. Research are needed to further evaluate neuropsychological communication errors. Conveying the clinical implications of neuropsychological results in a manner that minimizes risk for communication errors is a quintessential component of evidence-based practice. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Influence of Multifocal Intraocular Lenses on Standard Automated Perimetry Test Results

    NARCIS (Netherlands)

    Aychoua, Nancy; Montolio, Francisco G. Junoy; Jansonius, Nomdo M.

    Importance: A multifocal intraocular lens (MFIOL) allows for spectacle independence after cataract surgery and is thus a seemingly attractive option. However, several optical limitations have been reported or can be hypothesized. Objective: To evaluate the influence of an MFIOL on standard automated

  11. Size-dependent standard deviation for growth rates: Empirical results and theoretical modeling

    Science.gov (United States)

    Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H. Eugene; Grosse, I.

    2008-05-01

    We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation σ(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation σ(R) on the average value of the wages with a scaling exponent β≈0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation σ(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of σ(R) on the average payroll with a scaling exponent β≈-0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.

  12. Limiting Debye temperature behavior following from cryogenic heat capacity data for group-IV, III-V, and II-VI materials

    Energy Technology Data Exchange (ETDEWEB)

    Paessler, R. [Technische Universitaet Chemnitz, Institut fuer Physik, 09107 Chemnitz (Germany)

    2010-01-15

    We perform analyses of cryogenic heat capacity data sets, that are available from thermo-physical literature for group-IV materials (diamond, Si, Ge, and 3C-SiC), a variety of III-V materials (BN, BP, BAs, GaN, GaP, GaAs, GaSb, InP, InAs, InSb), and several II-VI materials (ZnO, ZnS, ZnSe, CdS, and CdTe). A prominent new result of the present study consists above all in a general high-precision formula, {theta}{sub D}(T)= {theta}{sub D}(0)(1+a{sub 2}T{sup 2}+a{sub 4}T{sup 4}){sup -1/3}, for the limiting behavior of the Debye temperature in the liquid helium-hydrogen region. The actual magnitudes of limiting Debye temperatures, {theta}{sub D}(0), in combination with the associated (throughout positive) curve shape coefficients, a{sub 2} and a{sub 4}, are given in unambiguous way in terms of the three lowest-order heat capacity coefficients involved by conventional Taylor series expansions for lattice heat capacities within the cryogenic range up to temperatures of order {theta}{sub D}(0){theta}{sub D}(0)/30. Among the variety of presently specified calorimetric {theta}{sub D}(0) values, particularly those obtained for a series of wide-bandgap materials may be of considerable interest. These are about 1110 K for 3C-SiC, 1860 for c-BN, 950 K for BP, 592 K for GaN, 429 or 392 K for isotopically modified samples {sup 64}Zn {sup 16}O and {sup 68}Zn {sup 18}O, respectively, 414 K for natural ZnO, 349 K for ZnS, 276 K for ZnSe, and 236 K for CdS. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  13. Preliminary results on 3D channel modeling: From theory to standardization

    KAUST Repository

    Kammoun, Abla

    2014-06-01

    Three dimensional (3D) beamforming (also elevation beamforming) is now gaining interest among researchers in wireless communication. The reason can be attributed to its potential for enabling a variety of strategies such as sector or user specific elevation beamforming and cell-splitting. Since these techniques cannot be directly supported by current LTE releases, the 3GPP is now working on defining the required technical specifications. In particular, a large effort is currently being made to get accurate 3D channel models that support the elevation dimension. This step is necessary as it will evaluate the potential of 3D and full dimensional (FD) beamforming techniques to benefit from the richness of real channels. This work aims at presenting the on-going 3GPP study item \\'study on 3D-channel model for elevation beamforming and FD-MIMO studies for LTE\\' and positioning it with respect to previous standardization works. © 2014 IEEE.

  14. Profile of osteopathic practice in Spain: results from a standardized data collection study.

    Science.gov (United States)

    Alvarez Bustins, Gerard; López Plaza, Pedro-Victor; Carvajal, Sonia Roura

    2018-04-11

    There is limited research regarding patients' profiles and consumer attitudes and habits of osteopathy in Spain. The purpose of this study was to profile patients who regularly receive osteopathic care in Spain using an internationally developed standardized data collection tool. During the period between April 2014 and December 2015, a UK-developed standardized data collection tool was distributed to Spanish osteopaths who voluntarily agreed to participate in this cross-sectional study. Thirty-six osteopaths participated in this study and returned a total of 314 completed datasets. Of 314 patients, 61% were women and 39% were men, with a mean age of 40 years (SD 17.02 years, range 0 to 83 years). Forty-four percent were full-time salaried workers, and in 78% of cases, receiving osteopathic treatment was the patient's own choice. Chronic spinal pain presentations were the most frequent reasons for consultation. Seventy-five percent of patients presented with a coexisting condition, mainly gastrointestinal disorders and headaches. The main treatment approach consisted of mobilization techniques, followed by soft tissue, cranial and high velocity thrust techniques. Improvement or resolution of the complaint was experienced by 93% of patients after a small number of sessions. Adverse events were minor and occurred in 7% of all cases. This is the first study carried out in Spain analyzing the profile of patients who receive osteopathic care. The typical patient who receives osteopathic care in Spain is middle-aged, presents mainly with chronic spinal pain, and voluntarily seeks osteopathic treatment. Osteopathic treatment produces a significant improvement in the majority of cases with a low rate of minor adverse events reported.

  15. Accuracy of portrayal by standardized patients: results from four OSCE stations conducted for high stakes examinations.

    Science.gov (United States)

    Baig, Lubna A; Beran, Tanya N; Vallevand, Andrea; Baig, Zarrukh A; Monroy-Cuadros, Mauricio

    2014-05-19

    The reliability in Objective Structured Clinical Exams (OSCEs) is based on variance introduced due to examiners, stations, items, standardized patients (SP), and the interaction of one or more of these items with the candidates. The impact of SPs on the reliability has not been well studied. Accordingly, the main purpose of the present study was to assess the accuracy of portrayal by standardized patients. Four stations from a ten station high-stakes OSCE were selected for video recording. Due to the large number of candidates to be evaluated, the OSCE was administered using four assessment tracks. Four SPs were trained for each case (n = 16). Two physician assessors were trained to assess the accuracy of SP portrayal using a station-specific instrument based on the station guidelines. For the items with disagreement a third physician was asked to review and the mode was used for analysis. Each instrument included case-specific items on verbal and physical portrayal using a 3-point rating scale ("yes", "yes, but" and "not done"). The physician assessors also scored each SP on their overall performance based on a 5-item anchored global rating scale ("very poor", "poor", "ok", "good", and "very good"). SPs at location 1 were trained by one trainer and SPs at location 2 had another trainer. All SPs were employed in a high-stakes OSCE for at least the second time. The reliability of rating scores ranged from Cronbach's alpha of .40 to .74. Verbal portrayal by SPs did not significantly differ for most items; however, the facial expressions of the SPs differed significantly (p OSCE may contribute substantial error to OSCE assessments. The training of SPs should be strengthened and constantly monitored during the exam to ensure that the examinees' scores are a true reflection of their competency and devoid of exam errors.

  16. First Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-01-01

    Considerable effort in the astronomy education research over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing astronomy as a sub-discipline of physics education research, allowing researchers to establish the initial knowledge state of students as well as to attempt to measure some of the impacts of innovative instructional interventions. Before now, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. Moving beyond the 10-year old Astronomy Diagnostics Test, we have developed and validated a new assessment instrument that is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this multiple-choice instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  17. Study on Temperature Characteristics of Frequency -domain Dielectric Spectrum of Capacitive Oil-paper Insulation Bushing Based on Extended Debye Model

    Science.gov (United States)

    Xu, X. W.; Pan, G.; Wang, K.; Liu, W. D.

    2017-07-01

    In order to study the influence of temperature on the frequency domain spectroscopy (FDS) of the oil-paper insulation system, the 72.5kV bushing test model was fabricated according to the actual size, and the FDS of the bushing was tested at different temperatures. According to the test curves of the dielectric constant at different temperatures, the influence of temperature on FDS is analysed, and then the extended Debye equivalent circuit model is used to fit the FDS test curves at different temperatures. The characteristic parameters that could be used to characterize the temperature characteristics are extracted, and the relationship between the characteristic parameters and the temperature is established. The results show that dielectric constant tend to move in the high frequency with the increase of temperature. The parameters of the equivalent circuit model are sensitive to the temperature, the insulation resistance Rg and the maximum time constant branch parameter R1 show the exponential function with the temperature, the minimum time constant branch parameter R3 and the temperature show a power function relationship, so the variation of characteristic parameters can be applied to evaluate the influence of temperature on the FDS of the oil-paper insulation bushing.

  18. Assessing the contributions of surface waves and complex rays to far-field Mie scattering by use of the Debye series

    Science.gov (United States)

    Hovenac, Edward A.; Lock, James A.

    1991-01-01

    The contributions of complex rays and the secondary radiation shed by surface waves to scattering by a dielectric sphere are calculated in the context of the Debye series expansion of the Mie scattering amplitudes. Also, the contributions of geometrical rays are reviewed and compared with the Debye series. Interference effects between surface waves, complex waves, and geometrical waves are calculated, and the possibility of observing these interference effects is discussed. Experimental data supporting the observation of a surface wave-geometrical pattern is presented.

  19. Calculation of NaCl, KCl and LiCl Salts Activity Coefficients in Polyethylene Glycol (PEG4000)-Water System Using Modified PHSC Equation of State, Extended Debye-Hückel Model and Pitzer Model

    Science.gov (United States)

    Marjani, Azam

    2016-07-01

    For biomolecules and cell particles purification and separation in biological engineering, besides the chromatography as mostly applied process, aqueous two-phase systems (ATPS) are of the most favorable separation processes that are worth to be investigated in thermodynamic theoretically. In recent years, thermodynamic calculation of ATPS properties has attracted much attention due to their great applications in chemical industries such as separation processes. These phase calculations of ATPS have inherent complexity due to the presence of ions and polymers in aqueous solution. In this work, for target ternary systems of polyethylene glycol (PEG4000)-salt-water, thermodynamic investigation for constituent systems with three salts (NaCl, KCl and LiCl) has been carried out as PEG is the most favorable polymer in ATPS. The modified perturbed hard sphere chain (PHSC) equation of state (EOS), extended Debye-Hückel and Pitzer models were employed for calculation of activity coefficients for the considered systems. Four additional statistical parameters were considered to ensure the consistency of correlations and introduced as objective functions in the particle swarm optimization algorithm. The results showed desirable agreement to the available experimental data, and the order of recommendation of studied models is PHSC EOS > extended Debye-Hückel > Pitzer. The concluding remark is that the all the employed models are reliable in such calculations and can be used for thermodynamic correlation/predictions; however, by using an ion-based parameter calculation method, the PHSC EOS reveals both reliability and universality of applications.

  20. The standardization of 133Ba: international comparison of results (June 1984)

    International Nuclear Information System (INIS)

    Meyer, B.R.

    1985-01-01

    Participation in an international intercomparison of measurements of the activity of a 133 Ba solution is described. The 4π (LS) -γ coincidence extrapolation method was used. Results for two different γ-channels were obtained. A graphical representation of the results obtained by the different participating laboratories is given

  1. 75 FR 33578 - Certain Welded Carbon Steel Standard Pipes and Tubes from India: Preliminary Results of...

    Science.gov (United States)

    2010-06-14

    ...) (implementing the 1997 regulations), and Oil Country Tubular Goods from Japan: Preliminary Results of...), unchanged in Oil Country Tubular Goods from Japan: Final Results and Partial Rescission of Antidumping Duty... statistic (where all sample statistics were for five days) of ``All C&I Loans 31 365 days'' from the Federal...

  2. Temperature dependence of the lattice parameter and Debye-Waller factor of a high-chromium pressure-vessel steel

    Science.gov (United States)

    Sumin, V. V.; Simkin, V. G.; Sheverev, S. G.; Leont'eva-Smirnova, M. V.; Chernov, V. M.

    2009-12-01

    The method of thermal neutron diffraction has been used to study samples of the EK-181 steel at temperatures of 15 to 973 K in an IBR-2 reactor (Joint Institute for Nuclear Research (JINR)). Temperature dependences of the lattice parameter, internal textural stresses (of the third kind), and the Debye-Waller factor of this steel have been calculated from diffraction spectra by the Rietveld method. It has been found that at low temperatures the temperature dependence of the lattice parameter in the EK-181 steel (RUSFER EK-181) differs from the corresponding dependence in pure iron and binary iron-chromium alloys containing 12 and 16% Cr. Also, a broadening of the ( 200) reflection has been observed in the diffraction spectra of the EK-181 steel and the Fe-12Cr alloy, while it is not detected in the spectra of Fe-16Cr and pure iron.

  3. Effects of dielectric inhomogeneity on electrostatic twist rigidity of a helical biomolecule in Debye-Hückel regime

    Science.gov (United States)

    Rezaie-Dereshgi, Amir; Mohammad-Rafiee, Farshid

    2018-04-01

    The electrostatic interactions play a crucial role in biological systems. Here we consider an impermeable dielectric molecule in the solvent with a different dielectric constant. The electrostatic free energy in the problem is studied in the Debye-Hückel regime using the analytical Green function that is calculated in the paper. Using this electrostatic free energy, we study the electrostatic contribution to the twist rigidity of a double stranded helical molecule such as a DNA and an actin filament. The dependence of the electrostatic twist rigidity of the molecule to the dielectric inhomogeneity, structural parameters, and the salt concentration is studied. It is shown that, depending on the parameters, the electrostatic twist rigidity could be positive or negative.

  4. Long Range Debye-Hückel Correction for Computation of Grid-based Electrostatic Forces Between Biomacromolecules

    Energy Technology Data Exchange (ETDEWEB)

    Mereghetti, Paolo; Martinez, M.; Wade, Rebecca C.

    2014-06-17

    Brownian dynamics (BD) simulations can be used to study very large molecular systems, such as models of the intracellular environment, using atomic-detail structures. Such simulations require strategies to contain the computational costs, especially for the computation of interaction forces and energies. A common approach is to compute interaction forces between macromolecules by precomputing their interaction potentials on three-dimensional discretized grids. For long-range interactions, such as electrostatics, grid-based methods are subject to finite size errors. We describe here the implementation of a Debye-Hückel correction to the grid-based electrostatic potential used in the SDA BD simulation software that was applied to simulate solutions of bovine serum albumin and of hen egg white lysozyme.

  5. Standardization of the Alberta infant motor scale in full-term Greek infants: Preliminary results.

    Science.gov (United States)

    Syrengelas, D; Siahanidou, T; Kourlaba, G; Kleisiouni, P; Bakoula, C; Chrousos, G P

    2010-04-01

    The Alberta Infant Motor Scale (AIMS) is a norm-referenced test that assesses the spontaneous motor performance of infants from birth through independent walking (0-18 months). This scale has been utilized for clinical and research purposes in various countries, however, whether the initial standardization in Canadian infants is also representative of other countries' populations has been questioned. To assess whether the AIMS needs new reference values for Greek infants. A cohort of 424 healthy full-term infants (250 boys and 174 girls), aged between 7 days and 18 months, derived from various areas of the Prefecture of Attica and from all socio-economic classes to ensure a true representation, was studied. The AIMS-scores of Greek infants were compared with the norm-referenced values of the original Canadian population reported by Piper and Darrah. The mean AIMS-scores did not differ significantly between Greek and Canadian infants at any age level from birth to 18 months, except for the 2-<3 month of age when higher scores were observed in Greek infants (p=0.02). There was no significant difference in AIMS-values corresponding to the 5th and 90th percentile between Greek and Canadian infants. Inter-rater reliability was excellent in our study population [ICC: 0.99 (95% CI: 0.99-0.99)]. In healthy full-term Greek infants, gross motor maturity assessed by the AIMS during the first 18 months of age, seems to follow a similar course to that of Canadian infants. 2010 Elsevier Ireland Ltd. All rights reserved.

  6. [Standardization of weaning of the mechanical ventilation in a Intensive Care Unit: results afterwards one year].

    Science.gov (United States)

    Oliveira, Luiz Rogério de Carvalho; José, Anderson; Dias, Elaine Cristina Polleti; Ruggero, Cíntia; Molinari, Camila Viteli; Chiavone, Paulo Antonio

    2006-06-01

    The weaning of mechanical ventilation is the process of transition from mechanical ventilation to spontaneous. The actual practice weaning reveals that the empirism is insufficient and inadequate. On the other side, the standardization of the weaning provides best conductions in the process. The objective of this study was to evaluate the effects of the application of a weaning protocol in an intensive care unit. It was included in this study all the patients in program of liberation from the mechanical ventilation, in which the evolution of the weaning was followed by the utilization of a pre-establish protocol and publicated by the service. It was studied 127 patients. In 91% (115) of the patients we had success in the weaning and unsuccess in 9% (12). The non-invasive ventilation after the extubation was utilized in 19% (24) of them. None obit was observed. Comparing the group of the patients that had success with the failed group, there were no statistically significant variations observed in sex (p = 0.96), APACHE II (19.5 versus 18.6 p = 0.75), risk of obit (29% versus 22% p = 0.54), MIP (38 versus 32 cmH2O p = 0.17), duration of mechanical ventilation (6 versus 7 days p = 0.70), PaO2/FiO2 relation (324 versus 312 p = 0.83), weaning modality (PSV or T Tube p = 0.29). There were statistically significant variations observed in rapid shallow respiratory index (59 versus 77 p = 0.02) and duration of the weaning (1 versus 30 hours p improvement in its conduction, maintaining the high success index with low mortality.

  7. Immunohistochemical Labelling for Cyclo-oxygenase-2: Does the Positive Control Guarantee Standardized Results?

    Science.gov (United States)

    Belluco, S; Carnier, P; Castagnaro, M; Chiers, K; Millanta, F; Peña, L; Pires, I; Queiroga, F; Riffard, S; Scase, T; Polton, G

    2016-01-01

    Since the identification of cyclo-oxygenase-2 as a potentially important therapeutic target in veterinary oncology, numerous studies on its expression have been conducted. Unfortunately, results have been heterogeneous and conclusions are difficult to draw. We tested the ability of a defined positive control to guarantee reproducibility of results among different laboratories. Valid positive controls were defined by positivity of the renal macula densa without background labelling. Fifteen colorectal tumours and 15 oral squamous cell carcinomas were labelled immunohistochemically by six European laboratories. Slides were evaluated in blinded fashion for percentage of positive cells and labelling intensity by three pathologists, and results were analyzed statistically for reproducibility and inter-reader variability. Macula densa positivity was an insufficiently sensitive control to guarantee reproducible results for percentage of positive cells and labelling intensity. Inter-reader variability was proven statistically, making the case for image analysis or other automated quantitative evaluation techniques. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Expressive Language in Preschoolers Born Preterm: Results of Language Sample Analysis and Standardized Assessment

    Science.gov (United States)

    Imgrund, Caitlin

    2017-01-01

    Children born preterm constitute one of the largest populations of children at risk for the development of language impairments. A little over one in ten pregnancies result in a preterm birth and approximately 25% of these children go on to experience subsequent difficulties with language (CDC, 2015; Foster-Cohen, Friesen, Champion, &…

  9. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  10. Off-Planar Geometry and Structural Instability of EDO-TTF Explained by Using the Extended Debye Polarizability Model for Bond Angles

    NARCIS (Netherlands)

    Linker, Gerrit-Jan; van Duijnen, Piet Th.; van Loosdrecht, Paul H. M.; Broer-Braam, Henderika

    2012-01-01

    The geometry of ethylenedioxy-tetrathiafulvalene, EDO-TTF, plays an important role in the metal-insulator transition in the charge transfer salt (EDO-TTF)(2)PF6. The planar and off-planar geometrical conformations of the EDO-TTF molecules are explained using an extended Debye polarizability model

  11. Telerehabilitation after arthroscopic subacromial decompression is effective and not inferior to standard practice: Preliminary results.

    Science.gov (United States)

    Pastora-Bernal, Jose Manuel; Martín-Valero, Rocío; Barón-López, Francisco Javier; Guerrero Moyano, Noelia; Estebanez-Pérez, María-José

    2017-01-01

    Background Telerehabilitation promises to improve quality, increase patient access and reduce costs in health care. Physiotherapy with exercises is generally recommended to restore function after surgery in patients with chronic subacromial syndrome. Relatively few studies have investigated the feasibility of telerehabilitation interventions in musculoskeletal and orthopaedic disorders. The aim of this study was to evaluate the feasibility and effectiveness of a customizable telerehabilitation intervention and compare with traditional care. Methods This research includes 18 consecutive patients with subacromial impingement who underwent arthroscopic subacromial decompression in a controlled clinical prospective study. Patients were randomized to either a 12-week telerehabilitation programme or the usual face-to-face physical therapy for immediate postoperative rehabilitation. We have developed a telerehabilitation system to provide services to patients who have undergone shoulder arthroscopy. An independent blinded observer performed postoperative follow-up after 4, 8, and 12 weeks. Results The preliminary efficacy of this telerehabilitation programme in terms of both physical and functional objective outcome measures was assessed on eight patients. Using the Constant-Murley score to evaluate functional outcome, patients in the telerehabilitation group were shown to have improved from a mean 43.50 ± 3.21 points to a mean 68.50 ± 0.86 points after 12 weeks. The physical and functional improvements in the telerehabilitation group were similar to those in the control group ( p = 0.213). There was a non-significant trend for greater improvements in the telerehabilitation group for most outcome measurements. Conclusion The results of this study provide evidence for the efficacy of telerehabilitation after shoulder arthroscopy in shoulder impingement syndrome. A telerehabilitation programme with range of motion, strengthening of the rotator cuff and scapula

  12. Subcell Debye behavior analysis of order–disorder effects in triple-junction InGaP-based photovoltaic solar cells

    International Nuclear Information System (INIS)

    Hsiao, Jui-Ju; Chen, Hung-Ing; Huang, Yi-Jen; Wang, Jen-Cheng; Lu, Bing-Yuh; Wu, Ya-Fen; Nee, Tzer-En

    2015-01-01

    Analysis was made of the Subcell Debye behavior of the order–disorder effects in triple-junction InGaP-based photovoltaic solar cells fabricated by a metal organic vapor phase epitaxy (MOVPE) system with careful adjustment of the growth conditions. The order–disorder configurations of the InGaP subcells were investigated after post-annealing treatment at various temperatures in a nitrogen atmosphere. Temperature-dependent photoluminescence (PL) measurements over a broad temperature range provided insight into the roles of the thermophysical phenomena connected with the ordering and disordering in the InGaP alloys. The thermally-related spectroscopic observations associated with the ordering effects on the photon–phonon interactions were confirmed by the McCumber–Sturge theory. The variations of both the full width at half-maximum (FWHM) and shift in the peak of PL with temperature were analyzed. According to the width-related PL observations the effective photon–phonon coupling coefficient and the Debye temperature were 0.53 meV and 424 K, respectively; according to shift-related PL observations of the as-grown sample they were 0.3247 eV and 430 K, respectively, for the width-related PL observation they were 0.29 meV and 421 K; and from the shift-related PL observations for the as-grown ordered samples they were 0.3142 eV and 425 K, respectively, implying that the spontaneously disordered InGaP heterostructures met the demand for improvement of photovoltaic devices. Both the effective photon–phonon coupling coefficient and the Debye temperatures were characterized as functions of the annealing temperature. The Debye temperatures obtained for the disordered and ordered top subcells were consistent with the universal Gruneisen–Bloch relation. - Highlights: • Analysis was made of the Subcell Debye behavior in photovoltaic solar cells. • The order–disorder configurations of the InGaP subcells were investigated. • The Debye temperatures were

  13. Patch Test Results with Standard and Cosmetic Series in Patients with Suspected Cosmetic-Induced Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Şenay Hacıoğlu

    2010-12-01

    Full Text Available Background and Design: Our aim was to evaluate the hypersensitivity to cosmetic chemicals in patients with clinically suspected cosmetic-induced contact dermatitis in Bursa and the South Marmara Region (Turkey by patch testing with standard and cosmetic series.Material and Method: Seventy-three patients with clinically suspected contact dermatitis due to cosmetics were patch tested by the European standard series and cosmetic series. The patch test results were analyzed as percentages. x2 test was used to demonstrate the relationship between cosmetic products and cosmetic allergens.Results: 90.4% of patients in our study group were female and 9.6% were male; the median age was 37.5 (range 16-71 years. The most commonly involved parts of the body were the face (49.3%, hands (16.4%, periocular region (6.8%, lips (6.8%, and the neck (5.5%. The most common offending cosmetic products causing allergic contact dermatitis were soaps and cleansing lotions (32.8%, moisturizer creams (21.9%, make-up (15.0%, and hair dyes (9.6%. 41.0% of patients showed positive reaction to at least one cosmetic allergen included in either standard or cosmetic series. The cosmetic allergens in the standard series and the rates of positivity were as follows: fragrance mix (6.8%, lanolin alcohols (5.5%, paraphenylenedaimine (2.7%, colophony (1.4%, paraben mix (1.4%, formaldehyde (1.4%, and methylchloroisothiazolinone (Kathon CG in descending order. The most common offending cosmetic allergen groups were preservatives (21.9%, antioxidants (8.2% and fragrances (6.8%. Conclusion: Allergic or irritant contact dermatitis due to cosmetics should be considered in cases of eczema involving face, neck, eyelids, lips, scalp or hands. Patch testing with cosmetic series beside standard series would be more helpful in detecting the responsible allergen(s.

  14. Analysis of radiation pressure force exerted on a biological cell induced by high-order Bessel beams using Debye series

    International Nuclear Information System (INIS)

    Li, Renxian; Ren, Kuan Fang; Han, Xiang'e; Wu, Zhensen; Guo, Lixin; Gong, Shuxi

    2013-01-01

    Debye series expansion (DSE) is employed to the analysis of radiation pressure force (RPF) exerted on biological cells induced by high-order Bessel beams (BB). The beam shape coefficients (BSCs) for high-order Bessel beams are calculated using analytical expressions obtained by the integral localized approximation (ILA). Different types of cells, including a real Chinese Hamster Ovary (CHO) cell and a lymphocyte which are respectively modeled by a coated and five-layered sphere, are considered. The RPF induced by high-order Bessel beams is compared with that by Gaussian beams and zeroth-order Bessel beams, and the effect of different scattering processes on RPF is studied. Numerical calculations show that high-order Bessel beams with zero central intensity can also transversely trap particle in the beam center, and some scattering processes can provide longitudinal pulling force. -- Highlights: ► BSCs for high-order Bessel beam (HOBB) is derived using ILA. ► DSE is employed to study the RPF induced by HOBB exerted on multilayered cells. ► RPF is decided by radius relative to the interval of peaks in intensity profile. ► HOBB can also transversely trap high-index particle in the vicinity of beam axis. ► RPF for some scattering processes can longitudinally pull particles back

  15. Evaluation of macroscopic polarization and actuation abilities of electrostrictive dipolar polymers using the microscopic Debye/Langevin formalism

    International Nuclear Information System (INIS)

    Capsal, Jean-Fabien; Lallart, Mickaël; Galineau, Jeremy; Cottinet, Pierre-Jean; Sebald, Gaël; Guyomar, Daniel

    2012-01-01

    Electrostrictive polymers, as an important category of electroactive polymers, are known to have non-linear response in terms of actuation that strongly affects their dynamic performance and limits their applications. Very few models exist in the literature, and even fewer are capable of making reliable predictions under an electric field. In this paper, electrostrictive strain of dipolar polymeric systems is discussed through constitutive equations derived from the Boltzmann statistics and Debye/Langevin formalism. Macroscopic polarization is expressed as a function of the inherent microscopic parameters of the dielectric material. Electrostrictive strain, polarization and dielectric permittivity are described well by the model in terms of dipole moment and saturation of dipole orientation, allowing the physical definition of the electrostrictive coefficient Q. Maxwell forces generated by dipolar orientation inducing surface charges are also used to explain the electrostrictive strain of polymers. The assessment of this analysis through a comparison with experimental data shows good agreement between reported values and theoretical predictions. These materials are generally used in low-frequency applications, thus the interfacial phenomena that are responsible for low saturation electric field should not be omitted so as not to underestimate or overestimate the low electric field response of the electrostrictive strain. (paper)

  16. [Hearing aid fitting: Effect of doubling the standard rate on compliance, quality of results, and excess payments].

    Science.gov (United States)

    Braun, B; Dietrich, A; Akcicek, B; Wollenberg, B; Schönweiler, R; Löhler, J

    2015-12-01

    This study investigates the effect that doubling the standard rate for hearing aid fitting which is covered by statutory insurance has had on the size of excess payments and compliance, as well as on benefits for patients and their satisfaction. In April 2014, 859 members of a statutory insurance scheme (hkk) who received hearing aids in the 6 months prior to the reform were questioned on the timing and financial details of their hearing aid fitting, as well as on treatment compliance and quality of the results using a standardized questionnaire. In October 2014, the same questionnaire was used to collect these data from a further 622 insurance holders who had received hearing aids in the 8 months following introduction of the new regulation. Most of the questions concerning hearing quality corresponded to those of the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire. The project revealed a statistically significant decrease of 6 percent points in the proportion of hearing aid users who had to pay any excess whatsoever; from 80.6% to 74.1%. However, 40% of the insured persons continued to pay an excess of 1000 euros and more. The subjective hearing quality remained practically unimproved by the reform and was statistically, almost without exception, independent of whether hearing aid users wore expensive devices associated with a large excess, or devices available at the standard rate. Finally, the study confirmed a previously recognized usage pattern characterized by noncompliance. For example, approximately 40% of hearing aid users did not wear their device in the everyday environment. This observation was independent of the size of the excess and the timing of the most recent visit to the hearing aid acoustician. Despite doubling of the standard rate, three quarters of patients pay an excess--sometimes a substantial one. The subjective hearing quality was not improved by doubling the standard rate; the majority of patients continue to complain of

  17. High-pressure and high-temperature physical properties of half-metallic full-Heusler alloy Mn{sub 2}RuSi by first-principles and quasi-harmonic Debye model

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ting [State Key Laboratory of Advanced Processing and Recycling of Non-ferrous Metals, Lanzhou University of Technology, Lanzhou 730050 (China); School of Mathematics and Physics, Lanzhou Jiaotong University, Lanzhou 730070 (China); Ma, Qin, E-mail: maqin_lut@yeah.net [State Key Laboratory of Advanced Processing and Recycling of Non-ferrous Metals, Lanzhou University of Technology, Lanzhou 730050 (China); Sun, Xiao-Wei [School of Mathematics and Physics, Lanzhou Jiaotong University, Lanzhou 730070 (China); Liu, Zi-Jiang [School of Mathematics and Physics, Lanzhou Jiaotong University, Lanzhou 730070 (China); Department of Physics, Lanzhou City University, Lanzhou 730070 (China); Wei, Xiao-Ping [School of Mathematics and Physics, Lanzhou Jiaotong University, Lanzhou 730070 (China); Tian, Jun-Hong [School of Mathematics and Physics, Lanzhou Jiaotong University, Lanzhou 730070 (China); Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610065 (China)

    2017-02-15

    First-principles calculations based on density functional theory and quasi-harmonic Debye model are used to investigate the high-pressure and high-temperature physical properties, including the lattice constant, magnetic moment, density of states, pressure-volume-temperature relationship, bulk modulus, thermal expansivity, heat capacity, and Grüneisen parameter for the new Mn-based full-Heusler alloy Mn{sub 2}RuSi in CuHg{sub 2}Ti-type structure. The optimized equilibrium lattice constant is consistent with experimental and other theoretical results. The calculated total spin magnetic moment remains an integral value of 2.0 μ{sub B} in the lattice constant range of 5.454–5.758 Å, and then decreases very slowly with the decrease of lattice constant to 5.333 Å. By the spin resolved density of states calculations, we have shown that Mn{sub 2}RuSi compound presents half-metallic ferrimagnetic properties under the equilibrium lattice constant. The effects of temperature and pressure on bulk modulus, thermal expansivity, heat capacity, and Grüneisen parameter are opposite, which are consistent with a compression rate of volume. Furthermore, the results show that the effect of temperature is larger than pressure for heat capacity and the effect of high temperature and pressure on thermal expansion coefficient is small. All the properties of Mn{sub 2}RuSi alloy are summarized in the pressure range of 0–100 GPa and the temperature up to 1200 K. - Highlights: • High-pressure and high-temperature physical properties of Mn2RuSi were investigated. • Ferrimagnetic ground state has been confirmed in Mn2RuSi alloy. • The first-principle calculations and quasi-harmonic Debye model were used. • The pressure up to 100 GPa and the temperature up to 1200 K.

  18. Numerical analysis of finite Debye-length effects in induced-charge electro-osmosis

    DEFF Research Database (Denmark)

    Gregersen, Misha Marie; Andersen, Mathias Bækbo; Soni, G.

    2009-01-01

    For a microchamber filled with a binary electrolyte and containing a flat unbiased center electrode at one wall, we employ three numerical models to study the strength of the resulting induced-charge electro-osmotic (ICEO) flow rolls: (i) a full nonlinear continuum model resolving the double laye...

  19. Correlation between standard Charpy and sub-size Charpy test results of selected steels in upper shelf region

    Science.gov (United States)

    Konopík, P.; Džugan, J.; Bucki, T.; Rzepa, S.; Rund, M.; Procházka, R.

    2017-02-01

    Absorbed energy obtained from impact Charpy tests is one of the most important values in many applications, for example in residual lifetime assessment of components in service. Minimal absorbed energy is often the value crucial for extending components service life, e.g. turbines, boilers and steam lines. Using a portable electric discharge sampling equipment (EDSE), it is possible to sample experimental material non-destructively and subsequently produce mini-Charpy specimens. This paper presents a new approach in correlation from sub-size to standard Charpy test results.

  20. Off-planar geometry and structural instability of EDO-TTF explained by using the extended debye polarizability model for bond angles.

    Science.gov (United States)

    Linker, Gerrit-Jan; van Duijnen, Piet Th; van Loosdrecht, Paul H M; Broer, Ria

    2012-07-05

    The geometry of ethylenedioxy-tetrathiafulvalene, EDO-TTF, plays an important role in the metal-insulator transition in the charge transfer salt (EDO-TTF)(2)PF(6). The planar and off-planar geometrical conformations of the EDO-TTF molecules are explained using an extended Debye polarizability model for the bond angle. The geometrical structure of EDO-TTF is dictated by its four sulfur bond angles and these are, in turn, determined by the polarizability of the sulfur atoms. With Hartree-Fock and second-order Møller-Plesset perturbation theory calculations on EDO-TTF, TTF, H(2)S, and their oxygen and selenium substituted counterparts we confirm this hypothesis. The Debye polarizability model for bond angles relates directly the optimum bond angle with the polarizability of the center atom. Considering the (EDO-TTF)(2)PF(6) material in this light proves to be very fruitful.

  1. Simulating the thermodynamics of charging in weak polyelectrolytes: the Debye-Hückel limit

    Science.gov (United States)

    Rathee, Vikramjit S.; Sikora, Benjamin J.; Sidky, Hythem; Whitmer, Jonathan K.

    2018-01-01

    The coil-globule transition in weak (annealed) polyelectrolytes involves a subtle balance of pH, charge strength, and solvation forces. In this work, we utilize a coarse-grained hybrid grand-canonical Monte Carlo and molecular dynamics approach to explore the swelling behavior of weak linear and star polyelectrolytes under different ionic screening conditions and pH. Importantly, we are able to quantify topology-dependent effects in charging which arise at the core of star polymers. Our results are suggestive of suppression of charging in star weak polyelectrolytes in comparison to linear weak polyelectrolytes. Furthermore, we characterize the coil-globule transition in linear and star weak polyelectrolyte through expanded ensemble density-of-states simulations which suggest a change from a first order to second order phase transition moving from linear to star polyelectrolytes. Lastly, we characterize the inhomogeneous charging across the weak star polyelectrolyte through observed shifts in {{Δ }}{{{pK}}}{{o}}, and compare with experimental work. We discuss these results in relation to surfaces functionalized by weak polyelectrolyte brushes and weak polyelectrolyte-based drug delivery applications.

  2. Standardized inspections of food premises during the 2004 Athens Olympic Games: descriptive analysis and risk factors for unsatisfactory results.

    Science.gov (United States)

    Hadjichristodoulou, Christos; Mouchtouri, Varvara; Varzakas, Theodoros; Arvanitoyannis, Ioannis; Kremastinou, Jenny

    2008-08-01

    Standardized inspections of food premises are part of environmental health systems implemented worldwide. The food safety strategy for the 2004 Olympic Games included standardized inspections to ensure uniformity and consistency of procedures and effective electronic management of data. Inspections were carried out by 196 inspectors in the five Olympic cities: Athens, Thessalonica, Volos, Iraklio, and Patra. From January 2003 to September 2004, a total of 1,249 food premises were inspected. An unsatisfactory inspection result (C grade) was received by 347 (27.8%) food premises, a relatively satisfactory result (B grade) was received by 332 (26.6%), and a satisfactory result (A grade) was received by 570 (45.6%). About 16% of inspected premises did not hold a valid permit. Unsatisfactory inspection results were more frequent for premises located in the two largest Greek cities in comparison with the other smaller cities (relative risk = 1.95, 95% confidence interval [CI] = 1.36 to 2.80). Based on logistic regression analysis, unsatisfactory inspection results were positively associated with food premises that were not located on a ground floor (odds ratio [OR] = 2.56, 95% CI = 1.39 to 4.73) and negatively associated with application of hazard analysis critical control point (HACCP) principles (OR = 0.27, 95% CI = 0.10 to 0.71). Food hygiene education through formal training programs should be encouraged to improve compliance of food premises. Food premises located on hotel floors and serving buffet meals are at higher risk for unsatisfactory conditions. Businesses that implemented a HACCP system within their operations to ensure food safety operated under more hygienic conditions. Future inspections by Public Health Authorities should involve elements of audit after the legislation for the application of HACCP principles.

  3. Design reinforced concrete structures: Differences in procedure, formula, and results between Eurocode 2 and British Standard 8110

    Science.gov (United States)

    Rahim, Mustaqqim Abdul; Ying, Lum Chui; Shahidan, Shahiron; Ghazaly, Zuhayr Md.; Anudai, Shamilah; Bawadi, Nor Faizah; Isa, Nur Fitriah; Hassan, Zulkarnain; Habulat, Afifuddin; Ismail, Zul-Atfi

    2017-09-01

    This research is mainly about comparisons of reinforced concrete structure design based on Eurocode 2 and British Standard 8110. The reinforcement concrete element is designed by referring Eurocode 2 (EN1992-1-1) and British Standard 8110 (BS8110-1:1997) for comparing purpose. The work examples of the structural elements has been done in this research to obtain the area of reinforcement required. The differences in procedure, formula and result of area of steel required for the elements based on both of the codes are compared and tabulated. In this research, there are five part of reinforced concrete structure elements are designed which are continuous beams, one way slabs, braced and short column, pile cap, and cantilever retaining wall. From the result acquired, it shows that area of reinforcement required based on EC 2 is lesser than BS 8110 and the dimension required based on BS8110 is larger than EC 2. Meanwhile, the design based on Eurocode 2 came out with more economical structural elements compare to BS 8110 as lesser steel and concrete volume required.

  4. Thermodynamic geometry, condensation and Debye model of two-parameter deformed statistics

    Science.gov (United States)

    Mohammadzadeh, Hosein; Azizian-Kalandaragh, Yashar; Cheraghpour, Narges; Adli, Fereshteh

    2017-08-01

    We consider the statistical distribution function of a two parameter deformed system, namely qp-deformed bosons and fermions. Using a thermodynamic geometry approach, we derive the thermodynamic curvature of an ideal gas with particles obeying qp-bosons and qp-fermions. We show that the intrinsic statistic interaction of qp-bosons is attractive in all physical ranges, while it is repulsive for qp-fermions. Also, the thermodynamic curvature of qp-boson gas is singular at a specified value of fugacity and therefore, a phase transition such as Bose-Einstein condensation can take place. In the following, we compare the experimental and theoretical results of temperature-dependent specific heat capacity of some metallic materials in the framework of q and qp-deformed algebras.

  5. The effect of standardized patient feedback in teaching surgical residents informed consent: results of a pilot study.

    Science.gov (United States)

    Leeper-Majors, Kristine; Veale, James R; Westbrook, Thomas S; Reed, Kendall

    2003-01-01

    The purpose of this pilot study was to determine the effectiveness of using feedback from a standardized patient (SP) to teach a surgical resident (SR) informed consent (IC) protocol. Four general case types of increasing difficulty were tested in a longitudinal experimental design format. The four types of cases were appendectomy, cholecystectomy, colorectal cancer, and breast cancer. Eight SRs of varying years of completion in medical school served as subjects-four in the experimental group (received performance feedback from an SP) and four in the control group (received no SP feedback). Both the control and experimental groups participated in two patient encounters per case type. The first patient encounter served as the pretest, and the second patient encounter was the posttest. In each encounter, an SP rated the resident on 14 measures using an open-ended seven-point rating scale adopted and modified from the Brown University Interpersonal Skill Evaluation (BUISE). Each resident also reviewed a videotape of an expert giving IC between pretest and the posttest for basic instructional protocol. Random stratified sampling was used to equally distribute the residents by postgraduate years. A total of 16 SPs were used in this study. All patient/SR encounters were videotaped. There was a statistically significant overall change--pretest to posttest and across cases (p = 0.001). The group effect was statistically significant (p = 0.000), with the experimental group averaging about 10 points greater than the control group. Standardized patient feedback is an effective modality in teaching surgical residents informed consent protocol. This conclusion is tentative, due to the limitations of sample size. The results of this study support continued research on the effects of standardized patient feedback to teach informed consent to surgical residents.

  6. Thermal noise due to surface-charge effects within the Debye layer of endogenous structures in dendrites.

    Science.gov (United States)

    Poznanski, Roman R

    2010-02-01

    An assumption commonly used in cable theory is revised by taking into account electrical amplification due to intracellular capacitive effects in passive dendritic cables. A generalized cable equation for a cylindrical volume representation of a dendritic segment is derived from Maxwell's equations under assumptions: (i) the electric-field polarization is restricted longitudinally along the cable length; (ii) extracellular isopotentiality; (iii) quasielectrostatic conditions; and (iv) homogeneous medium with constant conductivity and permittivity. The generalized cable equation is identical to Barenblatt's equation arising in the theory of infiltration in fissured strata with a known analytical solution expressed in terms of a definite integral involving a modified Bessel function and the solution to a linear one-dimensional classical cable equation. Its solution is used to determine the impact of thermal noise on voltage attenuation with distance at any particular time. A regular perturbation expansion for the membrane potential about the linear one-dimensional classical cable equation solution is derived in terms of a Green's function in order to describe the dynamics of free charge within the Debye layer of endogenous structures in passive dendritic cables. The asymptotic value of the first perturbative term is explicitly evaluated for small values of time to predict how the slowly fluctuating (in submillisecond range) electric field attributed to intracellular capacitive effects alters the amplitude of the membrane potential. It was found that capacitive effects are almost negligible for cables with electrotonic lengths L>0.5 , contributes up to 10% of the signal for cables with electrotonic lengths in the range between 0.25thermal noise due to intracellular capacitive effects. The presence of significant thermal noise weakens the assumption of intracellular isopotentiality when approximating dendrites with compartments.

  7. Standard-based comprehensive detection of adverse drug reaction signals from nursing statements and laboratory results in electronic health records.

    Science.gov (United States)

    Lee, Suehyun; Choi, Jiyeob; Kim, Hun-Sung; Kim, Grace Juyun; Lee, Kye Hwa; Park, Chan Hee; Han, Jongsoo; Yoon, Dukyong; Park, Man Young; Park, Rae Woong; Kang, Hye-Ryun; Kim, Ju Han

    2017-07-01

    We propose 2 Medical Dictionary for Regulatory Activities-enabled pharmacovigilance algorithms, MetaLAB and MetaNurse, powered by a per-year meta-analysis technique and improved subject sampling strategy. This study developed 2 novel algorithms, MetaLAB for laboratory abnormalities and MetaNurse for standard nursing statements, as significantly improved versions of our previous electronic health record (EHR)-based pharmacovigilance method, called CLEAR. Adverse drug reaction (ADR) signals from 117 laboratory abnormalities and 1357 standard nursing statements for all precautionary drugs ( n   = 101) were comprehensively detected and validated against SIDER (Side Effect Resource) by MetaLAB and MetaNurse against 11 817 and 76 457 drug-ADR pairs, respectively. We demonstrate that MetaLAB (area under the curve, AUC = 0.61 ± 0.18) outperformed CLEAR (AUC = 0.55 ± 0.06) when we applied the same 470 drug-event pairs as the gold standard, as in our previous research. Receiver operating characteristic curves for 101 precautionary terms in the Medical Dictionary for Regulatory Activities Preferred Terms were obtained for MetaLAB and MetaNurse (0.69 ± 0.11; 0.62 ± 0.07), which complemented each other in terms of ADR signal coverage. Novel ADR signals discovered by MetaLAB and MetaNurse were successfully validated against spontaneous reports in the US Food and Drug Administration Adverse Event Reporting System database. The present study demonstrates the symbiosis of laboratory test results and nursing statements for ADR signal detection in terms of their system organ class coverage and performance profiles. Systematic discovery and evaluation of the wide spectrum of ADR signals using standard-based observational electronic health record data across many institutions will affect drug development and use, as well as postmarketing surveillance and regulation. © The Author 2017. Published by Oxford University Press on behalf of the American

  8. A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts.

    Directory of Open Access Journals (Sweden)

    Andrzej Polanczyk

    Full Text Available Currently, studies connected with Computational Fluid Dynamic (CFD techniques focus on assessing hemodynamic of blood flow in vessels in different conditions e.g. after stent-graft's placement. The paper propose a novel method of standardization of results obtained from calculations of stent-grafts' "pushing forces" (cumulative WSS--Wall Shear Stress, and describes its usefulness in diagnostic process. AngioCT data from 27 patients were used to reconstruct 3D geometries of stent-grafts which next were used to create respective reference cylinders. We made an assumption that both the side surface and the height of a stent-graft and a reference cylinder were equal. The proposed algorithm in conjunction with a stent-graft "pushing forces" on an implant wall, allowed us to determine which spatial configuration of a stent-graft predispose to the higher risk of its migration. For stent-grafts close to cylindrical shape (shape factor φ close to 1 WSS value was about 267 Pa, while for stent-grafts different from cylindrical shape (φ close to 2 WSS value was about 635 Pa. It was also noticed that deformation in the stent-graft's bifurcation part impaired blood flow hemodynamic. Concluding the proposed algorithm of standardization proved its usefulness in estimating the WSS values that may be useful in diagnostic process. Angular bends or tortuosity in bifurcations of an aortic implant should be considered in further studies of estimation of the risk of implantation failure.

  9. Peter Debye and Electrochemistry

    Indian Academy of Sciences (India)

    Keywords. Debye–Hückel theory; electrolytic conductivity; activity co-efficient; transport properties. Author Affiliations. A K Shukla1 T Prem Kumar2. Solid State and Structural Chemistry Unit, Indian Institute of Science, Bangalore 560 012, India. Electrochemical Power Systems Division Central Electrochemical Research ...

  10. An XML standard for the dissemination of annotated 2D gel electrophoresis data complemented with mass spectrometry results

    Directory of Open Access Journals (Sweden)

    Arthur John

    2004-01-01

    Full Text Available Abstract Background Many proteomics initiatives require a seamless bioinformatics integration of a range of analytical steps between sample collection and systems modeling immediately assessable to the participants involved in the process. Proteomics profiling by 2D gel electrophoresis to the putative identification of differentially expressed proteins by comparison of mass spectrometry results with reference databases, includes many components of sample processing, not just analysis and interpretation, are regularly revisited and updated. In order for such updates and dissemination of data, a suitable data structure is needed. However, there are no such data structures currently available for the storing of data for multiple gels generated through a single proteomic experiments in a single XML file. This paper proposes a data structure based on XML standards to fill the void that exists between data generated by proteomics experiments and storing of data. Results In order to address the resulting procedural fluidity we have adopted and implemented a data model centered on the concept of annotated gel (AG as the format for delivery and management of 2D Gel electrophoresis results. An eXtensible Markup Language (XML schema is proposed to manage, analyze and disseminate annotated 2D Gel electrophoresis results. The structure of AG objects is formally represented using XML, resulting in the definition of the AGML syntax presented here. Conclusion The proposed schema accommodates data on the electrophoresis results as well as the mass-spectrometry analysis of selected gel spots. A web-based software library is being developed to handle data storage, analysis and graphic representation. Computational tools described will be made available at http://bioinformatics.musc.edu/agml. Our development of AGML provides a simple data structure for storing 2D gel electrophoresis data.

  11. An XML standard for the dissemination of annotated 2D gel electrophoresis data complemented with mass spectrometry results.

    Science.gov (United States)

    Stanislaus, Romesh; Jiang, Liu Hong; Swartz, Martha; Arthur, John; Almeida, Jonas S

    2004-01-29

    Many proteomics initiatives require a seamless bioinformatics integration of a range of analytical steps between sample collection and systems modeling immediately assessable to the participants involved in the process. Proteomics profiling by 2D gel electrophoresis to the putative identification of differentially expressed proteins by comparison of mass spectrometry results with reference databases, includes many components of sample processing, not just analysis and interpretation, are regularly revisited and updated. In order for such updates and dissemination of data, a suitable data structure is needed. However, there are no such data structures currently available for the storing of data for multiple gels generated through a single proteomic experiments in a single XML file. This paper proposes a data structure based on XML standards to fill the void that exists between data generated by proteomics experiments and storing of data. In order to address the resulting procedural fluidity we have adopted and implemented a data model centered on the concept of annotated gel (AG) as the format for delivery and management of 2D Gel electrophoresis results. An eXtensible Markup Language (XML) schema is proposed to manage, analyze and disseminate annotated 2D Gel electrophoresis results. The structure of AG objects is formally represented using XML, resulting in the definition of the AGML syntax presented here. The proposed schema accommodates data on the electrophoresis results as well as the mass-spectrometry analysis of selected gel spots. A web-based software library is being developed to handle data storage, analysis and graphic representation. Computational tools described will be made available at http://bioinformatics.musc.edu/agml. Our development of AGML provides a simple data structure for storing 2D gel electrophoresis data.

  12. Main results of the standardization through anti-coincident from the Brazilian Laboratory for Metrology of Ionizing Radiations - LNMRI/IRD/CNEN-RJ in the last 8 years

    International Nuclear Information System (INIS)

    Silva, Carlos J. da

    2014-01-01

    The LNMRI implemented in 2006 a system of time keeping in anticoincidence live in this time and dead time extensible today 18 radionuclides were standardized. To store the results of these primary standardization the LNMRI/IRD reference with ionization chamber were calibrated with these standards. In this work will be discussed the main operational difficulties and components of uncertainty and the main results. (author)

  13. 76 FR 65179 - Certain Welded Carbon Steel Standard Pipe From Turkey: Extension of Time for Preliminary Results...

    Science.gov (United States)

    2011-10-20

    ... International Trade Administration Certain Welded Carbon Steel Standard Pipe From Turkey: Extension of Time for... countervailing duty order on certain welded carbon steel standard pipe from Turkey covering the period of review...: October 14, 2011. Christian Marsh, Deputy Assistant Secretary for Antidumping and Countervailing Duty...

  14. Fiscal 1997 report on the results of the international standardization R and D. Overall survey; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Sogo chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The paper summed up the results of the survey of tackling with the international standardization by enterprises and organizations involved in the standardization in the U.S., Europe and Japan, the results of the R and D on 20 themes for the international standardization, and the development toward the international standardization. As the R and D themes, the following were selected: the development of chemical method to analyze/evaluate metallic coatings of surface treated steel coating sheets, R and D of the basic evaluation method of functional composite particles, international standards for computer/manikins, basic technology of color image management, study on optimizing design/evaluation technology using quality engineering, study of the international standardization by economic evaluation of environmental impacts, R and D of the standardization of a method to test acceleration life of phosphorous acid fuel cells, development of a test method of halogen-free flame-retardant cables and a study of the cable standards, standard measuring methods of hormone effects of chemical substances, quantification of the sensory evaluation and international standardization in the paint field, experimental study on the international standardization for immunochemical measurement of chemical substances, etc. 24 figs., 16 tabs.

  15. A Multilingual Approach to Analysing Standardized Test Results: Immigrant Primary School Children and the Role of Languages Spoken in a Bi-/Multilingual Community

    Science.gov (United States)

    De Angelis, Gessica

    2014-01-01

    The present study adopts a multilingual approach to analysing the standardized test results of primary school immigrant children living in the bi-/multilingual context of South Tyrol, Italy. The standardized test results are from the Invalsi test administered across Italy in 2009/2010. In South Tyrol, several languages are spoken on a daily basis…

  16. results

    Directory of Open Access Journals (Sweden)

    Salabura Piotr

    2017-01-01

    Full Text Available HADES experiment at GSI is the only high precision experiment probing nuclear matter in the beam energy range of a few AGeV. Pion, proton and ion beams are used to study rare dielectron and strangeness probes to diagnose properties of strongly interacting matter in this energy regime. Selected results from p + A and A + A collisions are presented and discussed.

  17. First Results of the “Carbonaceous Aerosol in Rome and Environs (CARE” Experiment: Beyond Current Standards for PM10

    Directory of Open Access Journals (Sweden)

    Francesca Costabile

    2017-12-01

    future research directions. First, we found that BC and EC mass concentration in Rome are larger than those measured in similar urban areas across Europe (the urban background mass concentration of eBC in Rome in winter being on average 2.6 ± 2.5 μ g · m − 3 , mean eBC at the peak level hour being 5.2 (95% CI = 5.0–5.5 μ g · m − 3 . Then, we discussed significant variations of carbonaceous aerosol properties occurring with time scales of minutes, and questioned on the data averaging period used in current air quality standard for PM 10 (24-h. Third, we showed that the oxidative potential induced by aerosol depends on particle size and composition, the effects of toxicity being higher with lower mass concentrations and smaller particle size. Albeit this is a preliminary analysis, findings reinforce the need for an urgent update of existing air quality standards for PM 10 and PM 2.5 with regard to particle composition and size distribution, and data averaging period. Our results reinforce existing concerns about the toxicity of carbonaceous aerosols, support the existing evidence indicating that particle size distribution and composition may play a role in the generation of this toxicity, and remark the need to consider a shorter averaging period (<1 h in these new standards.

  18. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Maijers, M.C.; Ritt, M.J.P.F. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Niessen, F.B. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Jan van Goyen Clinic, Department of Plastic Surgery, Amsterdam (Netherlands); Veldhuizen, J.F.H. [MRI Centre, Amsterdam (Netherlands); Manoliu, R.A. [MRI Centre, Amsterdam (Netherlands); VU University Medical Centre, Department of Radiology, Amsterdam (Netherlands)

    2014-06-15

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  19. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    International Nuclear Information System (INIS)

    Maijers, M.C.; Ritt, M.J.P.F.; Niessen, F.B.; Veldhuizen, J.F.H.; Manoliu, R.A.

    2014-01-01

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  20. Complex Number Representation in RCBNS Form for Arithmetic Operations and Conversion of the Result into Standard Binary Form

    Directory of Open Access Journals (Sweden)

    Hatim Zaini

    2004-12-01

    Full Text Available paper introduces a novel method for complex number representation. The proposed Redundant Complex Binary Number System (RCBNS is developed by combining a Redundant Binary Number and a complex number in base (-1+j. Donald [1] and Walter Penny [2,3] represented complex numbers using base –j and (-1+j in the classified algorithmic models. A Redundant Complex Binary Number System consists of both real and imaginary-radix number systems that form a redundant integer digit set. This system is formed by using complex radix of (-1+j and a digit set of á= 3, where á assumes a value of -3, -2, -1, 0, 1, 2, 3. The arithmetic operations of complex numbers with this system treat the real and imaginary parts as one unit. The carry-free addition has the advantage of Redundancy in number representation in the arithmetic operations. Results of the arithmetic operations are in the RCBNS form. The two methods for conversion from the RCBNS form to the standard binary number form have been presented. In this paper the RCBNS reduces the number of steps required to perform complex number arithmetic operations, thus enhancing the speed.

  1. XML-based formulation of field theoretical models. A proposal for a future standard and data base for model storage, exchange and cross-checking of results

    International Nuclear Information System (INIS)

    Demichev, A.; Kryukov, A.; Rodionov, A.

    2002-01-01

    We propose an XML-based standard for formulation of field theoretical models. The goal of creation of such a standard is to provide a way for an unambiguous exchange and cross-checking of results of computer calculations in high energy physics. At the moment, the suggested standard implies that models under consideration are of the SM or MSSM type (i.e., they are just SM or MSSM, their submodels, smooth modifications or straightforward generalizations). (author)

  2. An International Collaboration To Standardize HIV-2 Viral Load Assays: Results from the 2009 ACHIEV2E Quality Control Study▿

    OpenAIRE

    Damond, F.; Benard, A.; Balotta, Claudia; Böni, Jürg; Cotten, Matthew; Duque, Vitor; Ferns, Bridget; Garson, Jeremy; Gomes, Perpetua; Gonçalves, Fátima; Gottlieb, Geoffrey; Kupfer, Bernd; Ruelle, Jean; Rodes, Berta; Soriano, Vicente

    2011-01-01

    Accurate HIV-2 plasma viral load quantification is crucial for adequate HIV-2 patient management and for the proper conduct of clinical trials and international cohort collaborations. This study compared the homogeneity of HIV-2 RNA quantification when using HIV-2 assays from ACHIEV2E study sites and either in-house PCR calibration standards or common viral load standards supplied to all collaborators. Each of the 12 participating laboratories quantified blinded HIV-2 samples, using its own H...

  3. The European standard series in 9 European countries, 2002/2003 - First results of the European Surveillance System on Contact Allergies

    NARCIS (Netherlands)

    Uter, W; Hegewald, J; Aberer, W; Ayala, F; Bircher, AJ; Brasch, J; Coenraads, PJ; Schuttelaar, Marielouise; Elsner, P; Fartasch, M; Mahler, V.; Fortina, AB; Frosch, PJ; Fuchs, T; Johansen, JD; Menne, T; Jolanki, R; Krecisz, B; Kiec-Swierczynska, M; Larese, F; Orton, D; Peserico, A; Rantanen, T; Schnuch, A

    Since January 2001, the European Surveillance System on Contact Allergies (ESSCA), supported by European Union funding (contract QLK4-CT-2001-00343), has started to collect patch-test data. This comprises a standardized clinical history and the patch-test results using the European standard series,

  4. Drop Tests Results Of Revised Closure Bolt Configuration Of The Standard Waste Box, Standard Large Box 2, And Ten Drum Overpack Packagings

    International Nuclear Information System (INIS)

    May, C.; Opperman, E.; Mckeel, C.

    2010-01-01

    The Transuranic (TRU) Disposition Project at Savannah River Site will require numerous transfers of radioactive materials within the site boundaries for sorting and repackaging. The three DOT Type A shipping packagings planned for this work have numerous bolts for securing the lids to the body of the packagings. In an effort to reduce operator time to open and close the packages during onsite transfers, thus reducing personnel exposure and costs, an evaluation was performed to analyze the effects of reducing the number of bolts required to secure the lid to the packaging body. The evaluation showed the reduction to one-third of the original number of bolts had no effect on the packagings capability to sustain vibratory loads, shipping loads, internal pressure loads, and the loads resulting from a 4-ft drop. However, the loads caused by the 4-ft drop are difficult to estimate and the study recommended each of the packages be dropped to show the actual effects on the package closure. Even with reduced bolting, the packagings were still required to meet the 49 CFR 178.350 performance criteria for Type A packaging. This paper discusses the effects and results of the drop testing of the three packagings.

  5. How Californians View Education Standards, Testing and Accountability: Results from the Third PACE/USC Rossier Poll

    Science.gov (United States)

    Plank, David N.; Brewer, Dominic J.; Polikoff, Morgan; Hall, Michelle

    2013-01-01

    California is in the midst of sweeping education changes. The state is rolling out the Common Core State Standards (CCSS) and a new system of assessments. Voters approved a temporary statewide tax increase that will provide additional funding to schools after years of spending cuts. The Legislature adopted a new system for funding schools (the…

  6. Information Literacy Standards and the World Wide Web: Results from a Student Survey on Evaluation of Internet Information Sources

    Science.gov (United States)

    Taylor, Arthur; Dalal, Heather A.

    2014-01-01

    Introduction: This paper aims to determine how appropriate information literacy instruction is for preparing students for these unmediated searches using commercial search engines and the Web. Method. A survey was designed using the 2000 Association of College and Research Libraries literacy competency standards for higher education. Survey…

  7. Compliance of the Stokes-Einstein model and breakdown of the Stokes-Einstein-Debye model for a urea-based supramolecular polymer of high viscosity.

    Science.gov (United States)

    Świergiel, Jolanta; Bouteiller, Laurent; Jadżyn, Jan

    2014-11-14

    Impedance spectroscopy was used for the study of the static and dynamic behavior of the electrical conductivity of a hydrogen-bonded supramolecular polymer of high viscosity. The experimental data are discussed in the frame of the Stokes-Einstein and Stokes-Einstein-Debye models. It was found that the translational movement of the ions is due to normal Brownian diffusion, which was revealed by a fulfillment of Ohm's law by the electric current and a strictly exponential decay of the current after removing the electric stimulus. The dependence of the dc conductivity on the viscosity of the medium fulfills the Stokes-Einstein model quite well. An extension of the model, by including in it the conductivity relaxation time, is proposed in this paper. A breakdown of the Stokes-Einstein-Debye model is revealed by the relations of the dipolar relaxation time to the viscosity and to the dc ionic conductivity. The importance of the C=O···H-N hydrogen bonds in that breakdown is discussed.

  8. A direct sensitivity approach to predict hourly ozone resulting from compliance with the National Ambient Air Quality Standard.

    Science.gov (United States)

    Simon, Heather; Baker, Kirk R; Akhtar, Farhan; Napelenok, Sergey L; Possiel, Norm; Wells, Benjamin; Timin, Brian

    2013-03-05

    In setting primary ambient air quality standards, the EPA's responsibility under the law is to establish standards that protect public health. As part of the current review of the ozone National Ambient Air Quality Standard (NAAQS), the US EPA evaluated the health exposure and risks associated with ambient ozone pollution using a statistical approach to adjust recent air quality to simulate just meeting the current standard level, without specifying emission control strategies. One drawback of this purely statistical concentration rollback approach is that it does not take into account spatial and temporal heterogeneity of ozone response to emissions changes. The application of the higher-order decoupled direct method (HDDM) in the community multiscale air quality (CMAQ) model is discussed here to provide an example of a methodology that could incorporate this variability into the risk assessment analyses. Because this approach includes a full representation of the chemical production and physical transport of ozone in the atmosphere, it does not require assumed background concentrations, which have been applied to constrain estimates from past statistical techniques. The CMAQ-HDDM adjustment approach is extended to measured ozone concentrations by determining typical sensitivities at each monitor location and hour of the day based on a linear relationship between first-order sensitivities and hourly ozone values. This approach is demonstrated by modeling ozone responses for monitor locations in Detroit and Charlotte to domain-wide reductions in anthropogenic NOx and VOCs emissions. As seen in previous studies, ozone response calculated using HDDM compared well to brute-force emissions changes up to approximately a 50% reduction in emissions. A new stepwise approach is developed here to apply this method to emissions reductions beyond 50% allowing for the simulation of more stringent reductions in ozone concentrations. Compared to previous rollback methods, this

  9. Incidence trends of cannabis and cocaine use from periodic Spanish general population surveys: effect of standardizing results by age structure.

    Science.gov (United States)

    Sánchez-Niubò, Albert; Sordo, Luis; Fortiana, Josep; Brugal, M Teresa; Domingo-Salvany, Antònia

    2013-08-01

    This study estimates life-time incidence trends of cannabis and cocaine use over 38 years from general population surveys of drug use (GPSDU) in Spain, taking into account changes of population age structure. Periodic cross-sectional studies. Eight biennial GPSDU from 1995 to 2009 in Spain. Interviewees aged 15-64 years who reported age of first ever cannabis and/or cocaine use between 10 and 64 years between 1971 and 2008. Estimates of raw and standardized incidences were calculated as a weighted mean of the incidences from all surveys. Standardization was conducted to take into account changes of population age structure. Incidence trends were extracted applying weighted cubic smoothing splines to incidence estimates. For both substances, estimated raw incidence trends increased up until 2000 (rates of 11.5 ± 0.7 and 3.6 ± 0.5 per 1000, respectively, for cannabis and cocaine), and then decreased significantly (in 2008, 9.6 ± 1.2 and 2.7 ± 0.6, respectively). In contrast, standardized rates exhibit a steadily increasing trend up to 2000 (9.0 ± 0.6 and 2.8 ± 0.4), followed by a statistically non-significant increasing trend afterwards (in 2008, 9.5 ± 1.2 and 2.8 ± 0.6). The largest increases of incidence were observed in both male and female subjects aged 15-19 years. Using data from Spanish general population surveys of drug use, an apparently decreasing trend of raw incidence rates in both cannabis and cocaine use from 2000 became non-decreasing trends when these rates were standardized. First experiences of cannabis and cocaine use in Spain occur mainly in younger ages (15-19 years). © 2013 Society for the Study of Addiction.

  10. [New standards for catecholamine therapy in cardiopulmonary resuscitation? Results of a modified application in a resuscitation model].

    Science.gov (United States)

    Hörnchen, U; Lussi, C; Schüttler, J

    1992-06-01

    Using a standardized porcine CPR-model (3 min of cardiac arrest induced by ventricular fibrillation) the effects of epinephrine (10 micrograms/kg iv, 50 micrograms/kg iv, 100 micrograms/kg endobronchially, eb) and norepinephrine (10 micrograms/kg iv, 100 micrograms/kg eb) on resuscitability and early post-resuscitation haemodynamics were compared. Success rate was 100% after epinephrine 10 micrograms/kg iv and 100 micrograms/kg eb, 75% after epinephrine 50 micrograms/kg iv, 80% after norepinephrine iv and 60% after norepinephrine eb. In an unmedicated control group 50% of all animals were successfully resuscitated. Early post-resuscitation haemodynamics in the high dose epinephrine group were characterized by tachycardia and progredient myocardial failure, while in the norepinephrine groups a low cardiac output was accompanied by small cardiac stroke volumes and an increased vascular resistance. It is concluded that iv or eb epinephrine given in standard doses has still to be considered as the drug therapy of choice after short term cardiac arrest or in the presence of ventricular fibrillation. Before different drugs or dosing strategies can be recommended, further experimental and clinical validation is required.

  11. Modified risk stratification grouping using standard clinical and biopsy information for patients undergoing radical prostatectomy: Results from SEARCH.

    Science.gov (United States)

    Zumsteg, Zachary S; Chen, Zinan; Howard, Lauren E; Amling, Christopher L; Aronson, William J; Cooperberg, Matthew R; Kane, Christopher J; Terris, Martha K; Spratt, Daniel E; Sandler, Howard M; Freedland, Stephen J

    2017-12-01

    Prostate cancer is a heterogeneous disease, and risk stratification systems have been proposed to guide treatment decisions. However, significant heterogeneity remains for those with unfavorable-risk disease. This study included 3335 patients undergoing radical prostatectomy without adjuvant radiotherapy in the SEARCH database. High-risk patients were dichotomized into standard and very high-risk (VHR) groups based on primary Gleason pattern, percentage of positive biopsy cores (PPBC), number of NCCN high-risk factors, and stage T3b-T4 disease. Similarly, intermediate-risk prostate cancer was separated into favorable and unfavorable groups based on primary Gleason pattern, PPBC, and number of NCCN intermediate-risk factors. Median follow-up was 78 months. Patients with VHR prostate cancer had significantly worse PSA relapse-free survival (PSA-RFS, P < 0.001), distant metastasis (DM, P = 0.004), and prostate cancer-specific mortality (PCSM, P = 0.015) in comparison to standard high-risk (SHR) patients in multivariable analyses. By contrast, there was no significant difference in PSA-RFS, DM, or PCSM between SHR and unfavorable intermediate-risk (UIR) patients. Therefore, we propose a novel risk stratification system: Group 1 (low-risk), Group 2 (favorable intermediate-risk), Group 3 (UIR and SHR), and Group 4 (VHR). The c-index of this new grouping was 0.683 for PSA-RFS and 0.800 for metastases, compared to NCCN-risk groups which yield 0.666 for PSA-RFS and 0.764 for metastases. Patients classified as VHR have markedly increased rates of PSA relapse, DM, and PCSM in comparison to SHR patients, whereas UIR and SHR patients have similar prognosis. Novel therapeutic strategies are needed for patients with VHR, likely involving multimodality therapy. © 2017 Wiley Periodicals, Inc.

  12. An international collaboration to standardize HIV-2 viral load assays: results from the 2009 ACHI(E)V(2E) quality control study.

    Science.gov (United States)

    Damond, F; Benard, A; Balotta, Claudia; Böni, Jürg; Cotten, Matthew; Duque, Vitor; Ferns, Bridget; Garson, Jeremy; Gomes, Perpetua; Gonçalves, Fátima; Gottlieb, Geoffrey; Kupfer, Bernd; Ruelle, Jean; Rodes, Berta; Soriano, Vicente; Wainberg, Mark; Taieb, Audrey; Matheron, Sophie; Chene, Genevieve; Brun-Vezinet, Francoise

    2011-10-01

    Accurate HIV-2 plasma viral load quantification is crucial for adequate HIV-2 patient management and for the proper conduct of clinical trials and international cohort collaborations. This study compared the homogeneity of HIV-2 RNA quantification when using HIV-2 assays from ACHI(E)V(2E) study sites and either in-house PCR calibration standards or common viral load standards supplied to all collaborators. Each of the 12 participating laboratories quantified blinded HIV-2 samples, using its own HIV-2 viral load assay and standard as well as centrally validated and distributed common HIV-2 group A and B standards (http://www.hiv.lanl.gov/content/sequence/HelpDocs/subtypes-more.html). Aliquots of HIV-2 group A and B strains, each at 2 theoretical concentrations (2.7 and 3.7 log(10) copies/ml), were tested. Intralaboratory, interlaboratory, and overall variances of quantification results obtained with both standards were compared using F tests. For HIV-2 group A quantifications, overall and interlaboratory and/or intralaboratory variances were significantly lower when using the common standard than when using in-house standards at the concentration levels of 2.7 log(10) copies/ml and 3.7 log(10) copies/ml, respectively. For HIV-2 group B, a high heterogeneity was observed and the variances did not differ according to the type of standard used. In this international collaboration, the use of a common standard improved the homogeneity of HIV-2 group A RNA quantification only. The diversity of HIV-2 group B, particularly in PCR primer-binding regions, may explain the heterogeneity in quantification of this strain. Development of a validated HIV-2 viral load assay that accurately quantifies distinct circulating strains is needed.

  13. Non-Debye relaxation and resonance phenomena in dielectric spectra of CaCu3Ti4O12 family functional ceramic materials

    Science.gov (United States)

    Turik, A. V.; Bogatin, A. S.

    2015-01-01

    Experimental data on dielectric spectra of calcium copper titanate, CaCu3Ti4O12 (CCTO) family functional ceramics have been studied and analyzed. It is shown that there are both non-Debye relaxation and resonance regions in their spectra. An occurrence of a retardation of complex permittivity and a relaxation of electric modulus is established. An average relaxation frequency of the electric modulus is considerably (in some cases several orders of magnitude) larger than the retardation frequency of the permittivity. A parallel connection of the capacity and complex conductivity is used to model and interpret experimental data on a negative permittivity in the infralow frequency range. Computer simulation enables us to reveal that the hopping conductivity, characteristic for disordered heterogeneous systems, is to be taken into account to describe adequately experimental data on passing the real part of the capacity (or permittivity) through zero. We have found a critical frequency at which the parallel resonance would take place.

  14. Population pharmacokinetics of piperacillin in the early phase of septic shock: does standard dosing result in therapeutic plasma concentrations?

    Science.gov (United States)

    Öbrink-Hansen, Kristina; Juul, Rasmus Vestergaard; Storgaard, Merete; Thomsen, Marianne Kragh; Hardlei, Tore Forsingdal; Brock, Birgitte; Kreilgaard, Mads; Gjedsted, Jakob

    2015-11-01

    Antibiotic dosing in septic shock patients poses a challenge for clinicians due to the pharmacokinetic (PK) variability seen in this patient population. Piperacillin-tazobactam is often used for empirical treatment, and initial appropriate dosing is crucial for reducing mortality. Accordingly, we determined the pharmacokinetic profile of piperacillin (4 g) every 8 h, during the third consecutive dosing interval, in 15 patients treated empirically for septic shock. We developed a population pharmacokinetic model to assess empirical dosing and to simulate alternative dosing regimens and modes of administration. Time above the MIC (T>MIC) predicted for each patient was evaluated against clinical breakpoint MIC for Pseudomonas aeruginosa (16 mg/liter). Pharmacokinetic-pharmacodynamic (PK/PD) targets evaluated were 50% fT>4×MIC and 100% fT>MIC. A population PK model was developed using NONMEM, and data were best described by a two-compartment model. Central and intercompartmental clearances were 3.6 liters/h (relative standard error [RSE], 15.7%) and 6.58 liters/h (RSE, 16.4%), respectively, and central and peripheral volumes were 7.3 liters (RSE, 11.8%) and 3.9 liters (RSE, 9.7%), respectively. Piperacillin plasma concentrations varied considerably between patients and were associated with levels of plasma creatinine. Patients with impaired renal function were more likely to achieve predefined PK/PD targets than were patients with preserved or augmented renal function. Simulations of alternative dosing regimens showed that frequent intermittent bolus dosing as well as dosing by extended and continuous infusion increases the probability of attaining therapeutic plasma concentrations. For septic shock patients with preserved or augmented renal function, dose increment or prolonged infusion of the drug needs to be considered. (This study has been registered at ClinicalTrials.gov under registration no. NCT02306928.). Copyright © 2015, American Society for Microbiology

  15. Comparison of the precision of two standardized co-ordinate systems for the quantitation of brain anatomy: preliminary results.

    Science.gov (United States)

    Sandor, T; Tieman, J; Ong, H T; Moss, M B; Jolesz, F; Albert, M

    1994-10-01

    We assessed reproducible definition of two standardized co-ordinate systems for intersubject analysis of brain images. The baselines in the two co-ordinate systems were a modification of the canthomeatal (mCM) line and the anterior-posterior commissural (AC-PC) line. Axial spin-echo MR images of four subjects at 1.5T were used. Operator error was computed from the replicate analyses of two operators. The mCM line was determined by the lens of the eye and the internal auditory canal, and the AC-PC line was determined by the intersection of AC and PC with the interhemispheric fissure. Reproducibility of the mCM markers (SD = 0.59 mm) did not differ significantly from that of the AC-PC line (SD = 0.68 mm). The measurement error of the angle of the baseline (delta alpha), however, was more than 7 times as large for the AC-PC line as for the mCM line. An additional error affecting the rostrocaudal rotation of the co-ordinate systems, attributable to the distance between the anatomic markers, was 2.1 and 3.6 degrees (3 mm and 5 mm slice thickness) for the mCM co-ordinate system and 8.2 and 11.0 degrees (3 mm and 5 mm slice thickness) for the AC-PC system. The AC-PC line based co-ordinate system is therefore, less reproducible than the mCM line based system. This could be improved if a combination of axial and sagittal images were used for the definition of the AC-PC line.

  16. DICOM for quantitative imaging biomarker development: a standards based approach to sharing clinical data and structured PET/CT analysis results in head and neck cancer research

    Directory of Open Access Journals (Sweden)

    Andriy Fedorov

    2016-05-01

    Full Text Available Background. Imaging biomarkers hold tremendous promise for precision medicine clinical applications. Development of such biomarkers relies heavily on image post-processing tools for automated image quantitation. Their deployment in the context of clinical research necessitates interoperability with the clinical systems. Comparison with the established outcomes and evaluation tasks motivate integration of the clinical and imaging data, and the use of standardized approaches to support annotation and sharing of the analysis results and semantics. We developed the methodology and tools to support these tasks in Positron Emission Tomography and Computed Tomography (PET/CT quantitative imaging (QI biomarker development applied to head and neck cancer (HNC treatment response assessment, using the Digital Imaging and Communications in Medicine (DICOM® international standard and free open-source software. Methods. Quantitative analysis of PET/CT imaging data collected on patients undergoing treatment for HNC was conducted. Processing steps included Standardized Uptake Value (SUV normalization of the images, segmentation of the tumor using manual and semi-automatic approaches, automatic segmentation of the reference regions, and extraction of the volumetric segmentation-based measurements. Suitable components of the DICOM standard were identified to model the various types of data produced by the analysis. A developer toolkit of conversion routines and an Application Programming Interface (API were contributed and applied to create a standards-based representation of the data. Results. DICOM Real World Value Mapping, Segmentation and Structured Reporting objects were utilized for standards-compliant representation of the PET/CT QI analysis results and relevant clinical data. A number of correction proposals to the standard were developed. The open-source DICOM toolkit (DCMTK was improved to simplify the task of DICOM encoding by introducing new API

  17. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    NARCIS (Netherlands)

    Maijers, M.C.; Niessen, F.B.; Veldhuizen, J.F.H.; Ritt, M.J.P.F.; Manoliu, R.A.

    2014-01-01

    Objectives: The recall of Poly Implant Prothèse (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in

  18. [Results of a standardized survey on the medical use of cannabis products in the German-speaking area].

    Science.gov (United States)

    Schnelle, M; Grotenhermen, F; Reif, M; Gorter, R W

    1999-10-01

    The plant Cannabis sativa has a long history of medical use in the treatment of pain and spasms, the promotion of sleep, and the suppression of nausea and vomiting. However, in the early 70s cannabis was classified in the Narcotic Acts in countries all over the world as having no therapeutic benefit; therefore, it cannot be prescribed by physicians or dispensed by pharmacists. In the light of this contradictory situation an increasing number of patients practices a self-prescription with cannabis products for relieving a variety of symptoms. An anonymous standardized survey of the medical use of cannabis and cannabis products of patients in Germany, Austria and Switzerland was conducted by the Association for Cannabis as Medicine (Cologne, Germany). During about one year 170 subjects participated in this survey; questionnaires of 128 patients could be included into the evaluation. 68% of these participants were males, 32% females, with a total mean age of 37.5 (+/- 9.6) years. The most frequently mentioned indications for medicinal cannabis use were depression (12.0%), multiple sclerosis (10.8%), HIV-infection (9.0%), migraine (6.6%), asthma (6.0%), back pain (5.4%), hepatitis C (4. 8%), sleeping disorders (4.8%), epilepsy (3.6%), spasticity (3.6%), headache (3.6%), alcoholism (3.0%), glaucoma (3.0%), nausea (3.0%), disk prolapse (2.4%), and spinal cord injury (2.4%). The majority of patients used natural cannabis products such as marihuana, hashish and an alcoholic tincture; in just 5 cases dronabinol (Marinol) was taken by prescription. About half of the 128 participants of the survey (52.4%) had used cannabis as a recreational drug before the onset of their illness. To date 14.3% took cannabis orally, 49.2% by inhalation and in 36.5% of cases both application modes were used. 72.2% of the patients stated the symptoms of their illness to have 'much improved' after cannabis ingestion, 23.4% stated to have 'slightly improved', 4.8% experienced 'no change' and 1

  19. Pet Food Palatability Evaluation: A Review of Standard Assay Techniques and Interpretation of Results with a Primary Focus on Limitations

    OpenAIRE

    Aldrich, Gregory C.; Koppel, Kadri

    2015-01-01

    Simple Summary Palatability of pet foods is typically measured using a single-bowl or a two-bowl test. While these tests give a general understanding of the liking or preference of one food over another, opportunities exist for further method development. Abstract The pet food industry continues to grow steadily as a result of new innovative products. Quality control and product development tests for pet foods are typically conducted through palatability testing with dogs and cats. Palatabili...

  20. Pet Food Palatability Evaluation: A Review of Standard Assay Techniques and Interpretation of Results with a Primary Focus on Limitations.

    Science.gov (United States)

    Aldrich, Gregory C; Koppel, Kadri

    2015-01-16

    The pet food industry continues to grow steadily as a result of new innovative products. Quality control and product development tests for pet foods are typically conducted through palatability testing with dogs and cats. Palatability is the measure of intake of a food that indicates acceptance or the measure of preference of one food over another. Pet food palatability is most commonly measured using a single-bowl or a two-bowl assay. While these tests answer some questions about the animals' perception of the food, there are many limitations as well. This review addresses some of these limitations and indicates opportunities for future research.

  1. Pet Food Palatability Evaluation: A Review of Standard Assay Techniques and Interpretation of Results with a Primary Focus on Limitations

    Directory of Open Access Journals (Sweden)

    Gregory C. Aldrich

    2015-01-01

    Full Text Available The pet food industry continues to grow steadily as a result of new innovative products. Quality control and product development tests for pet foods are typically conducted through palatability testing with dogs and cats. Palatability is the measure of intake of a food that indicates acceptance or the measure of preference of one food over another. Pet food palatability is most commonly measured using a single-bowl or a two-bowl assay. While these tests answer some questions about the animals’ perception of the food, there are many limitations as well. This review addresses some of these limitations and indicates opportunities for future research.

  2. The European standard series in 9 European countries, 2002/2003 -- first results of the European Surveillance System on Contact Allergies

    DEFF Research Database (Denmark)

    Uter, W; Hegewald, J; Aberer, W

    2005-01-01

    Since January 2001, the European Surveillance System on Contact Allergies (ESSCA), supported by European Union funding (contract QLK4-CT-2001-00343), has started to collect patch-test data. This comprises a standardized clinical history and the patch-test results using the European standard series...... observed. The prevalence of contact allergy to Myroxylon pereirae resin (balsam of Peru) (5.8%) is coming close to the frequency found with the fragrance mix (6.4%). Regarding contact allergy to chromium compounds, different frequencies were noted in the 2 centres focused on occupational dermatitis (2...

  3. PRELIMINARY RESULTS OF THE COMPARISON OF SATELLITE IMAGERS USING TUZ GÖLÜ AS A REFERENCE STANDARD

    Directory of Open Access Journals (Sweden)

    H. Özen

    2012-07-01

    Full Text Available Earth surfaces, such as deserts, salt lakes, and playas, have been widely used in the vicarious radiometric calibration of optical earth observation satellites. In 2009, the Infrared and Visible Optical Sensors (IVOS sub-group of the Committee of Earth Observation Satellites (CEOS Working Group on Calibration and Validation (WGCV designated eight LANDNET reference sites to focus international efforts, facilitate traceability and enable the establishment of measurement "best practices." With support from the European Space Agency (ESA, one of the LANDNET sites, the Tuz Gölü salt lake located in central Turkey, was selected to host a cross-comparison of measurement instrumentation and methodologies conducted by 11 different ground teams across the globe. This paper provides an overview of the preliminary results of the cross-comparison of the ground-based spectral measurements made during the CEOS Land Comparison 13-27 August, 2010 with the simultaneous satellite image data acquisitions of the same site.

  4. Neoadjuvant capecitabine combined with standard radiotherapy in patients with locally advanced rectal cancer. Mature results of a phase II trial

    Energy Technology Data Exchange (ETDEWEB)

    Dunst, J. [Dept. of Radiotherapy, Univ. of Luebeck (Germany); Debus, J. [Univ. of Heidelberg (Germany); Rudat, V. [Univ. of Hamburg (Germany); Wulf, J. [Univ. of Wuerzburg (Germany); Budach, W. [Univ. of Tuebingen (Germany); Hoelscher, T. [Technical Univ., Dresden (Germany); Reese, T. [Martin Luther Univ., Halle (Germany); Mose, S.; Roedel, C. [Univ. of Frankfurt (Germany); Zuehlke, H. [Paul Gerhard Hospital, Wittenberg (Germany); Hinke, A. [WiSP GmbH, Langenfeld (Germany)

    2008-09-15

    Purpose: the objective of this expanded phase II trial was to confirm the safety results of the preceding phase I study and establish the efficacy of neoadjuvant radiochemotherapy with capecitabine in rectal cancer in a multicenter setting. Patients and methods: 96 patients (63% male, age 34-81 years) with advanced rectal cancer (cT3-4 or cN+) from seven university centers in Germany were recruited. All were to receive a total irradiation dose of 50.4-55.8 Gy with conventional fractions. Capecitabine was given at an oral dosage of 825 mg/m{sup 2} bid on each day of the radiotherapy period with the first daily dose applied 2 h before irradiation, followed by surgery 6 weeks later. Results: most of the patients suffered from an advanced primary tumor (cT3: 57%, cT4: 40%) with lymph node involvement in 60%. After neoadjuvant treatment, with a mean of 99% of the scheduled radiation dose actually delivered, a clinical response rate of 68% (95% confidence interval: 57-78%) was observed. Out of 87 evaluable patients undergoing surgery, a sphincter-preserving procedure could be performed in 51% and RO resection in 94%. A pathologically complete response was achieved in six patients (7%, 95% confidence interval: 3-14%). The comparison of initial diagnosis and pathologic findings showed a downstaging in 61%. Acute toxicity with > 5% incidence of NCI (National Cancer Institute) grade {>=} 3 included lymphopenia (12%), leukopenia (6%), and diarrhea (7%). Mild to moderate hand-foot syndrome occurred in 12% only. After a median follow-up of 48 months, the 5-year overall survival and tumor control data were, with regard to patient selection, in the expected range with an overall survival of 65%, a relapse-free survival of 47%, and a local recurrence rate after 5 years of 17%. Conclusion: the data clearly confirm that capecitabine is an adequate substitute for 5-fluorouracil in preoperative chemoradiation of rectal cancer with a favorable safety profile. (orig.)

  5. Results of the Phase I Dose-Escalating Study of Motexafin Gadolinium With Standard Radiotherapy in Patients With Glioblastoma Multiforme

    International Nuclear Information System (INIS)

    Ford, Judith M.; Seiferheld, Wendy; Alger, Jeffrey R.; Wu, Genevieve; Endicott, Thyra J.; Mehta, Minesh; Curran, Walter; Phan, See-Chun

    2007-01-01

    Purpose: Motexafin gadolinium (MGd) is a putative radiation enhancer initially evaluated in patients with brain metastases. This Phase I trial studied the safety and tolerability of a 2-6-week course (10-22 doses) of MGd with radiotherapy for glioblastoma multiforme. Methods and Materials: A total of 33 glioblastoma multiforme patients received one of seven MGd regimens starting at 10 doses of 4 mg/kg/d MGd and escalating to 22 doses of 5.3 mg/kg/d MGd (5 or 10 daily doses then three times per week). The National Cancer Institute Cancer Therapy Evaluation Program toxicity and stopping rules were applied. Results: The maximal tolerated dose was 5.0 mg/kg/d MGd (5 d/wk for 2 weeks, then three times per week) for 22 doses. The dose-limiting toxicity was reversible transaminase elevation. Adverse reactions included rash/pruritus (45%), chills/fever (30%), and self-limiting vesiculobullous rash of the thumb and fingers (42%). The median survival of 17.6 months prompted a case-matched analysis. In the case-matched analysis, the MGd patients had a median survival of 16.1 months (n = 31) compared with the matched Radiation Therapy Oncology Group database patients with a median survival of 11.8 months (hazard ratio, 0.43; 95% confidence interval, 0.20-0.94). Conclusion: The maximal tolerated dose of MGd with radiotherapy for glioblastoma multiforme in this study was 5 mg/kg/d for 22 doses (daily for 2 weeks, then three times weekly). The baseline survival calculations suggest progression to Phase II trials is appropriate, with the addition of MGd to radiotherapy with concurrent and adjuvant temozolomide

  6. Combined results of searches for the standard model Higgs boson in pp collisions at $\\sqrt{s}$ = 7 TeV

    CERN Document Server

    Chatrchyan, Serguei; Sirunyan, Albert M; Tumasyan, Armen; Adam, Wolfgang; Bergauer, Thomas; Dragicevic, Marko; Erö, Janos; Fabjan, Christian; Friedl, Markus; Fruehwirth, Rudolf; Ghete, Vasile Mihai; Hammer, Josef; Hoch, Michael; Hörmann, Natascha; Hrubec, Josef; Jeitler, Manfred; Kiesenhofer, Wolfgang; Krammer, Manfred; Liko, Dietrich; Mikulec, Ivan; Pernicka, Manfred; Rahbaran, Babak; Rohringer, Christine; Rohringer, Herbert; Schöfbeck, Robert; Strauss, Josef; Taurok, Anton; Teischinger, Florian; Wagner, Philipp; Waltenberger, Wolfgang; Walzel, Gerhard; Widl, Edmund; Wulz, Claudia-Elisabeth; Mossolov, Vladimir; Shumeiko, Nikolai; Suarez Gonzalez, Juan; Bansal, Sunil; Benucci, Leonardo; Cornelis, Tom; De Wolf, Eddi A; Janssen, Xavier; Luyckx, Sten; Maes, Thomas; Mucibello, Luca; Ochesanu, Silvia; Roland, Benoit; Rougny, Romain; Selvaggi, Michele; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Remortel, Nick; Van Spilbeeck, Alex; Blekman, Freya; Blyweert, Stijn; D'Hondt, Jorgen; Gonzalez Suarez, Rebeca; Kalogeropoulos, Alexis; Maes, Michael; Olbrechts, Annik; Van Doninck, Walter; Van Mulders, Petra; Van Onsem, Gerrit Patrick; Villella, Ilaria; Charaf, Otman; Clerbaux, Barbara; De Lentdecker, Gilles; Dero, Vincent; Gay, Arnaud; Hammad, Gregory Habib; Hreus, Tomas; Léonard, Alexandre; Marage, Pierre Edouard; Thomas, Laurent; Vander Velde, Catherine; Vanlaer, Pascal; Wickens, John; Adler, Volker; Beernaert, Kelly; Cimmino, Anna; Costantini, Silvia; Garcia, Guillaume; Grunewald, Martin; Klein, Benjamin; Lellouch, Jérémie; Marinov, Andrey; Mccartin, Joseph; Ocampo Rios, Alberto Andres; Ryckbosch, Dirk; Strobbe, Nadja; Thyssen, Filip; Tytgat, Michael; Vanelderen, Lukas; Verwilligen, Piet; Walsh, Sinead; Yazgan, Efe; Zaganidis, Nicolas; Basegmez, Suzan; Bruno, Giacomo; Ceard, Ludivine; De Favereau De Jeneret, Jerome; Delaere, Christophe; Du Pree, Tristan; Favart, Denis; Forthomme, Laurent; Giammanco, Andrea; Grégoire, Ghislain; Hollar, Jonathan; Lemaitre, Vincent; Liao, Junhui; Militaru, Otilia; Nuttens, Claude; Pagano, Davide; Pin, Arnaud; Piotrzkowski, Krzysztof; Schul, Nicolas; Beliy, Nikita; Caebergs, Thierry; Daubie, Evelyne; Alves, Gilvan; Correa Martins Junior, Marcos; De Jesus Damiao, Dilson; Martins, Thiago; Pol, Maria Elena; Henrique Gomes E Souza, Moacyr; Aldá Júnior, Walter Luiz; Carvalho, Wagner; Custódio, Analu; Melo Da Costa, Eliza; De Oliveira Martins, Carley; Fonseca De Souza, Sandro; Matos Figueiredo, Diego; Mundim, Luiz; Nogima, Helio; Oguri, Vitor; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Silva Do Amaral, Sheila Mara; Soares Jorge, Luana; Sznajder, Andre; Souza Dos Anjos, Tiago; Bernardes, Cesar Augusto; De Almeida Dias, Flavia; Tomei, Thiago; De Moraes Gregores, Eduardo; Lagana, Caio; Da Cunha Marinho, Franciole; Mercadante, Pedro G; Novaes, Sergio F; Padula, Sandra; Genchev, Vladimir; Iaydjiev, Plamen; Piperov, Stefan; Rodozov, Mircho; Stoykova, Stefka; Sultanov, Georgi; Tcholakov, Vanio; Trayanov, Rumen; Vutova, Mariana; Dimitrov, Anton; Hadjiiska, Roumyana; Karadzhinova, Aneliya; Kozhuharov, Venelin; Litov, Leander; Pavlov, Borislav; Petkov, Peicho; Bian, Jian-Guo; Chen, Guo-Ming; Chen, He-Sheng; Jiang, Chun-Hua; Liang, Dong; Liang, Song; Meng, Xiangwei; Tao, Junquan; Wang, Jian; Wang, Jian; Wang, Xianyou; Wang, Zheng; Xiao, Hong; Xu, Ming; Zang, Jingjing; Zhang, Zhen; Asawatangtrakuldee, Chayanit; Ban, Yong; Guo, Shuang; Guo, Yifei; Li, Wenbo; Liu, Shuai; Mao, Yajun; Qian, Si-Jin; Teng, Haiyun; Wang, Siguang; Zhu, Bo; Zou, Wei; Cabrera, Andrés; Gomez Moreno, Bernardo; Osorio Oliveros, Andres Felipe; Sanabria, Juan Carlos; Godinovic, Nikola; Lelas, Damir; Plestina, Roko; Polic, Dunja; Puljak, Ivica; Antunovic, Zeljko; Dzelalija, Mile; Kovac, Marko; Brigljevic, Vuko; Duric, Senka; Kadija, Kreso; Luetic, Jelena; Morovic, Srecko; Attikis, Alexandros; Galanti, Mario; Mousa, Jehad; Nicolaou, Charalambos; Ptochos, Fotios; Razis, Panos A; Finger, Miroslav; Finger Jr, Michael; Assran, Yasser; Ellithi Kamel, Ali; Khalil, Shaaban; Mahmoud, Mohammed; Radi, Amr; Hektor, Andi; Kadastik, Mario; Müntel, Mait; Raidal, Martti; Rebane, Liis; Tiko, Andres; Azzolini, Virginia; Eerola, Paula; Fedi, Giacomo; Voutilainen, Mikko; Czellar, Sandor; Härkönen, Jaakko; Heikkinen, Mika Aatos; Karimäki, Veikko; Kinnunen, Ritva; Kortelainen, Matti J; Lampén, Tapio; Lassila-Perini, Kati; Lehti, Sami; Lindén, Tomas; Luukka, Panja-Riina; Mäenpää, Teppo; Peltola, Timo; Tuominen, Eija; Tuominiemi, Jorma; Tuovinen, Esa; Ungaro, Donatella; Wendland, Lauri; Banzuzi, Kukka; Korpela, Arja; Tuuva, Tuure; Sillou, Daniel; Besancon, Marc; Choudhury, Somnath; Dejardin, Marc; Denegri, Daniel; Fabbro, Bernard; Faure, Jean-Louis; Ferri, Federico; Ganjour, Serguei; Givernaud, Alain; Gras, Philippe; Hamel de Monchenault, Gautier; Jarry, Patrick; Locci, Elizabeth; Malcles, Julie; Millischer, Laurent; Rander, John; Rosowsky, André; Shreyber, Irina; Titov, Maksym; Baffioni, Stephanie; Beaudette, Florian; Benhabib, Lamia; Bianchini, Lorenzo; Bluj, Michal; Broutin, Clementine; Busson, Philippe; Charlot, Claude; Daci, Nadir; Dahms, Torsten; Dobrzynski, Ludwik; Elgammal, Sherif; Granier de Cassagnac, Raphael; Haguenauer, Maurice; Miné, Philippe; Mironov, Camelia; Ochando, Christophe; Paganini, Pascal; Sabes, David; Salerno, Roberto; Sirois, Yves; Thiebaux, Christophe; Veelken, Christian; Zabi, Alexandre; Agram, Jean-Laurent; Andrea, Jeremy; Bloch, Daniel; Bodin, David; Brom, Jean-Marie; Cardaci, Marco; Chabert, Eric Christian; Collard, Caroline; Conte, Eric; Drouhin, Frédéric; Ferro, Cristina; Fontaine, Jean-Charles; Gelé, Denis; Goerlach, Ulrich; Juillot, Pierre; Karim, Mehdi; Le Bihan, Anne-Catherine; Van Hove, Pierre; Fassi, Farida; Mercier, Damien; Baty, Clement; Beauceron, Stephanie; Beaupere, Nicolas; Bedjidian, Marc; Bondu, Olivier; Boudoul, Gaelle; Boumediene, Djamel; Brun, Hugues; Chasserat, Julien; Chierici, Roberto; Contardo, Didier; Depasse, Pierre; El Mamouni, Houmani; Falkiewicz, Anna; Fay, Jean; Gascon, Susan; Gouzevitch, Maxime; Ille, Bernard; Kurca, Tibor; Le Grand, Thomas; Lethuillier, Morgan; Mirabito, Laurent; Perries, Stephane; Sordini, Viola; Tosi, Silvano; Tschudi, Yohann; Verdier, Patrice; Viret, Sébastien; Lomidze, David; Anagnostou, Georgios; Beranek, Sarah; Edelhoff, Matthias; Feld, Lutz; Heracleous, Natalie; Hindrichs, Otto; Jussen, Ruediger; Klein, Katja; Merz, Jennifer; Ostapchuk, Andrey; Perieanu, Adrian; Raupach, Frank; Sammet, Jan; Schael, Stefan; Sprenger, Daniel; Weber, Hendrik; Wittmer, Bruno; Zhukov, Valery; Ata, Metin; Caudron, Julien; Dietz-Laursonn, Erik; Erdmann, Martin; Güth, Andreas; Hebbeker, Thomas; Heidemann, Carsten; Hoepfner, Kerstin; Klimkovich, Tatsiana; Klingebiel, Dennis; Kreuzer, Peter; Lanske, Dankfried; Lingemann, Joschka; Magass, Carsten; Merschmeyer, Markus; Meyer, Arnd; Olschewski, Mark; Papacz, Paul; Pieta, Holger; Reithler, Hans; Schmitz, Stefan Antonius; Sonnenschein, Lars; Steggemann, Jan; Teyssier, Daniel; Weber, Martin; Bontenackels, Michael; Cherepanov, Vladimir; Davids, Martina; Flügge, Günter; Geenen, Heiko; Geisler, Matthias; Haj Ahmad, Wael; Hoehle, Felix; Kargoll, Bastian; Kress, Thomas; Kuessel, Yvonne; Linn, Alexander; Nowack, Andreas; Perchalla, Lars; Pooth, Oliver; Rennefeld, Jörg; Sauerland, Philip; Stahl, Achim; Zoeller, Marc Henning; Aldaya Martin, Maria; Behrenhoff, Wolf; Behrens, Ulf; Bergholz, Matthias; Bethani, Agni; Borras, Kerstin; Burgmeier, Armin; Cakir, Altan; Calligaris, Luigi; Campbell, Alan; Castro, Elena; Dammann, Dirk; Eckerlin, Guenter; Eckstein, Doris; Flossdorf, Alexander; Flucke, Gero; Geiser, Achim; Hauk, Johannes; Jung, Hannes; Kasemann, Matthias; Katsas, Panagiotis; Kleinwort, Claus; Kluge, Hannelies; Knutsson, Albert; Krämer, Mira; Krücker, Dirk; Kuznetsova, Ekaterina; Lange, Wolfgang; Lohmann, Wolfgang; Lutz, Benjamin; Mankel, Rainer; Marfin, Ihar; Marienfeld, Markus; Melzer-Pellmann, Isabell-Alissandra; Meyer, Andreas Bernhard; Mnich, Joachim; Mussgiller, Andreas; Naumann-Emme, Sebastian; Olzem, Jan; Petrukhin, Alexey; Pitzl, Daniel; Raspereza, Alexei; Ribeiro Cipriano, Pedro M; Rosin, Michele; Salfeld-Nebgen, Jakob; Schmidt, Ringo; Schoerner-Sadenius, Thomas; Sen, Niladri; Spiridonov, Alexander; Stein, Matthias; Tomaszewska, Justyna; Walsh, Roberval; Wissing, Christoph; Autermann, Christian; Blobel, Volker; Bobrovskyi, Sergei; Draeger, Jula; Enderle, Holger; Erfle, Joachim; Gebbert, Ulla; Görner, Martin; Hermanns, Thomas; Höing, Rebekka Sophie; Kaschube, Kolja; Kaussen, Gordon; Kirschenmann, Henning; Klanner, Robert; Lange, Jörn; Mura, Benedikt; Nowak, Friederike; Pietsch, Niklas; Sander, Christian; Schettler, Hannes; Schleper, Peter; Schlieckau, Eike; Schmidt, Alexander; Schröder, Matthias; Schum, Torben; Stadie, Hartmut; Steinbrück, Georg; Thomsen, Jan; Barth, Christian; Berger, Joram; Chwalek, Thorsten; De Boer, Wim; Dierlamm, Alexander; Dirkes, Guido; Feindt, Michael; Gruschke, Jasmin; Guthoff, Moritz; Hackstein, Christoph; Hartmann, Frank; Heinrich, Michael; Held, Hauke; Hoffmann, Karl-Heinz; Honc, Simon; Katkov, Igor; Komaragiri, Jyothsna Rani; Kuhr, Thomas; Martschei, Daniel; Mueller, Steffen; Müller, Thomas; Niegel, Martin; Nürnberg, Andreas; Oberst, Oliver; Oehler, Andreas; Ott, Jochen; Peiffer, Thomas; Quast, Gunter; Rabbertz, Klaus; Ratnikov, Fedor; Ratnikova, Natalia; Renz, Manuel; Röcker, Steffen; Saout, Christophe; Scheurer, Armin; Schieferdecker, Philipp; Schilling, Frank-Peter; Schmanau, Mike; Schott, Gregory; Simonis, Hans-Jürgen; Stober, Fred-Markus Helmut; Troendle, Daniel; Wagner-Kuhr, Jeannine; Weiler, Thomas; Zeise, Manuel; Ziebarth, Eva Barbara; Daskalakis, Georgios; Geralis, Theodoros; Kesisoglou, Stilianos; Kyriakis, Aristotelis; Loukas, Demetrios; Manolakos, Ioannis; Markou, Athanasios; Markou, Christos; Mavrommatis, Charalampos; Ntomari, Eleni; Gouskos, Loukas; Mertzimekis, Theodoros; Panagiotou, Apostolos; Saoulidou, Niki; Stiliaris, Efstathios; Evangelou, Ioannis; Foudas, Costas; Kokkas, Panagiotis; Manthos, Nikolaos; Papadopoulos, Ioannis; Patras, Vaios; Triantis, Frixos A; Aranyi, Attila; Bencze, Gyorgy; Boldizsar, Laszlo; Hajdu, Csaba; Hidas, Pàl; Horvath, Dezso; Kapusi, Anita; Krajczar, Krisztian; Sikler, Ferenc; Veszpremi, Viktor; Vesztergombi, Gyorgy; Beni, Noemi; Molnar, Jozsef; Palinkas, Jozsef; Szillasi, Zoltan; Karancsi, János; Raics, Peter; Trocsanyi, Zoltan Laszlo; Ujvari, Balazs; Beri, Suman Bala; Bhatnagar, Vipin; Dhingra, Nitish; Gupta, Ruchi; Jindal, Monika; Kaur, Manjit; Kohli, Jatinder Mohan; Mehta, Manuk Zubin; Nishu, Nishu; Saini, Lovedeep Kaur; Sharma, Archana; Singh, Anil; Singh, Jasbir; Singh, Supreet Pal; Ahuja, Sudha; Choudhary, Brajesh C; Kumar, Ashok; Kumar, Arun; Malhotra, Shivali; Naimuddin, Md; Ranjan, Kirti; Sharma, Varun; Shivpuri, Ram Krishen; Banerjee, Sunanda; Bhattacharya, Satyaki; Dutta, Suchandra; Gomber, Bhawna; Jain, Sandhya; Jain, Shilpi; Khurana, Raman; Sarkar, Subir; Choudhury, Rajani Kant; Dutta, Dipanwita; Kailas, Swaminathan; Kumar, Vineet; Mohanty, Ajit Kumar; Pant, Lalit Mohan; Shukla, Prashant; Aziz, Tariq; Ganguly, Sanmay; Guchait, Monoranjan; Gurtu, Atul; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mohanty, Gagan Bihari; Parida, Bibhuti; Saha, Anirban; Sudhakar, Katta; Wickramage, Nadeesha; Banerjee, Sudeshna; Dugad, Shashikant; Mondal, Naba Kumar; Arfaei, Hessamaddin; Bakhshiansohi, Hamed; Etesami, Seyed Mohsen; Fahim, Ali; Hashemi, Majid; Hesari, Hoda; Jafari, Abideh; Khakzad, Mohsen; Mohammadi, Abdollah; Mohammadi Najafabadi, Mojtaba; Paktinat Mehdiabadi, Saeid; Safarzadeh, Batool; Zeinali, Maryam; Abbrescia, Marcello; Barbone, Lucia; Calabria, Cesare; Chhibra, Simranjit Singh; Colaleo, Anna; Creanza, Donato; De Filippis, Nicola; De Palma, Mauro; Fiore, Luigi; Iaselli, Giuseppe; Lusito, Letizia; Maggi, Giorgio; Maggi, Marcello; Manna, Norman; Marangelli, Bartolomeo; My, Salvatore; Nuzzo, Salvatore; Pacifico, Nicola; Pompili, Alexis; Pugliese, Gabriella; Romano, Francesco; Selvaggi, Giovanna; Silvestris, Lucia; Singh, Gurpreet; Tupputi, Salvatore; Zito, Giuseppe; Abbiendi, Giovanni; Benvenuti, Alberto; Bonacorsi, Daniele; Braibant-Giacomelli, Sylvie; Brigliadori, Luca; Capiluppi, Paolo; Castro, Andrea; Cavallo, Francesca Romana; Cuffiani, Marco; Dallavalle, Gaetano-Marco; Fabbri, Fabrizio; Fanfani, Alessandra; Fasanella, Daniele; Giacomelli, Paolo; Grandi, Claudio; Marcellini, Stefano; Masetti, Gianni; Meneghelli, Marco; Montanari, Alessandro; Navarria, Francesco; Odorici, Fabrizio; Perrotta, Andrea; Primavera, Federica; Rossi, Antonio; Rovelli, Tiziano; Siroli, Gianni; Travaglini, Riccardo; Albergo, Sebastiano; Cappello, Gigi; Chiorboli, Massimiliano; Costa, Salvatore; Potenza, Renato; Tricomi, Alessia; Tuve, Cristina; Barbagli, Giuseppe; Ciulli, Vitaliano; Civinini, Carlo; D'Alessandro, Raffaello; Focardi, Ettore; Frosali, Simone; Gallo, Elisabetta; Gonzi, Sandro; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Tropiano, Antonio; Benussi, Luigi; Bianco, Stefano; Colafranceschi, Stefano; Fabbri, Franco; Piccolo, Davide; Fabbricatore, Pasquale; Musenich, Riccardo; Benaglia, Andrea; De Guio, Federico; Di Matteo, Leonardo; Fiorendi, Sara; Gennai, Simone; Ghezzi, Alessio; Malvezzi, Sandra; Manzoni, Riccardo Andrea; Martelli, Arabella; Massironi, Andrea; Menasce, Dario; Moroni, Luigi; Paganoni, Marco; Pedrini, Daniele; Ragazzi, Stefano; Redaelli, Nicola; Sala, Silvano; Tabarelli de Fatis, Tommaso; Buontempo, Salvatore; Carrillo Montoya, Camilo Andres; Cavallo, Nicola; De Cosa, Annapaola; Dogangun, Oktay; Fabozzi, Francesco; Iorio, Alberto Orso Maria; Lista, Luca; Merola, Mario; Paolucci, Pierluigi; Azzi, Patrizia; Bacchetta, Nicola; Bellan, Paolo; Bisello, Dario; Branca, Antonio; Carlin, Roberto; Checchia, Paolo; Dorigo, Tommaso; Dosselli, Umberto; Fanzago, Federica; Gasparini, Fabrizio; Gasparini, Ugo; Gozzelino, Andrea; Kanishchev, Konstantin; Lacaprara, Stefano; Lazzizzera, Ignazio; Margoni, Martino; Mazzucato, Mirco; Meneguzzo, Anna Teresa; Nespolo, Massimo; Perrozzi, Luca; Pozzobon, Nicola; Ronchese, Paolo; Simonetto, Franco; Torassa, Ezio; Tosi, Mia; Vanini, Sara; Zotto, Pierluigi; Zumerle, Gianni; Berzano, Umberto; Gabusi, Michele; Ratti, Sergio P; Riccardi, Cristina; Torre, Paola; Vitulo, Paolo; Biasini, Maurizio; Bilei, Gian Mario; Caponeri, Benedetta; Fanò, Livio; Lariccia, Paolo; Lucaroni, Andrea; Mantovani, Giancarlo; Menichelli, Mauro; Nappi, Aniello; Romeo, Francesco; Santocchia, Attilio; Taroni, Silvia; Valdata, Marisa; Azzurri, Paolo; Bagliesi, Giuseppe; Boccali, Tommaso; Broccolo, Giuseppe; Castaldi, Rino; D'Agnolo, Raffaele Tito; Dell'Orso, Roberto; Fiori, Francesco; Foà, Lorenzo; Giassi, Alessandro; Kraan, Aafke; Ligabue, Franco; Lomtadze, Teimuraz; Martini, Luca; Messineo, Alberto; Palla, Fabrizio; Palmonari, Francesco; Rizzi, Andrea; Serban, Alin Titus; Spagnolo, Paolo; Tenchini, Roberto; Tonelli, Guido; Venturi, Andrea; Verdini, Piero Giorgio; Barone, Luciano; Cavallari, Francesca; Del Re, Daniele; Diemoz, Marcella; Fanelli, Cristiano; Grassi, Marco; Longo, Egidio; Meridiani, Paolo; Micheli, Francesco; Nourbakhsh, Shervin; Organtini, Giovanni; Pandolfi, Francesco; Paramatti, Riccardo; Rahatlou, Shahram; Sigamani, Michael; Soffi, Livia; Amapane, Nicola; Arcidiacono, Roberta; Argiro, Stefano; Arneodo, Michele; Biino, Cristina; Botta, Cristina; Cartiglia, Nicolo; Castello, Roberto; Costa, Marco; Demaria, Natale; Graziano, Alberto; Mariotti, Chiara; Maselli, Silvia; Migliore, Ernesto; Monaco, Vincenzo; Musich, Marco; Obertino, Maria Margherita; Pastrone, Nadia; Pelliccioni, Mario; Potenza, Alberto; Romero, Alessandra; Ruspa, Marta; Sacchi, Roberto; Sola, Valentina; Solano, Ada; Staiano, Amedeo; Vilela Pereira, Antonio; Belforte, Stefano; Cossutti, Fabio; Della Ricca, Giuseppe; Gobbo, Benigno; Marone, Matteo; Montanino, Damiana; Penzo, Aldo; Heo, Seong Gu; Nam, Soon-Kwon; Chang, Sunghyun; Chung, Jin Hyuk; Kim, Dong Hee; Kim, Gui Nyun; Kim, Ji Eun; Kong, Dae Jung; Park, Hyangkyu; Ro, Sang-Ryul; Son, Dong-Chul; Kim, Jae Yool; Kim, Zero Jaeho; Song, Sanghyeon; Jo, Hyun Yong; Choi, Suyong; Gyun, Dooyeon; Hong, Byung-Sik; Jo, Mihee; Kim, Hyunchul; Kim, Tae Jeong; Lee, Kyong Sei; Moon, Dong Ho; Park, Sung Keun; Seo, Eunsung; Sim, Kwang Souk; Choi, Minkyoo; Kang, Seokon; Kim, Hyunyong; Kim, Ji Hyun; Park, Chawon; Park, Inkyu; Park, Sangnam; Ryu, Geonmo; Cho, Yongjin; Choi, Young-Il; Choi, Young Kyu; Goh, Junghwan; Kim, Min Suk; Lee, Byounghoon; Lee, Jongseok; Lee, Sungeun; Seo, Hyunkwan; Yu, Intae; Bilinskas, Mykolas Jurgis; Grigelionis, Ignas; Janulis, Mindaugas; Castilla-Valdez, Heriberto; De La Cruz-Burelo, Eduard; Heredia-de La Cruz, Ivan; Lopez-Fernandez, Ricardo; Magaña Villalba, Ricardo; Martínez-Ortega, Jorge; Sánchez-Hernández, Alberto; Villasenor-Cendejas, Luis Manuel; Carrillo Moreno, Salvador; Vazquez Valencia, Fabiola; Salazar Ibarguen, Humberto Antonio; Casimiro Linares, Edgar; Morelos Pineda, Antonio; Reyes-Santos, Marco A; Krofcheck, David; Bell, Alan James; Butler, Philip H; Doesburg, Robert; Reucroft, Steve; Silverwood, Hamish; Ahmad, Muhammad; Asghar, Muhammad Irfan; Hoorani, Hafeez R; Khalid, Shoaib; Khan, Wajid Ali; Khurshid, Taimoor; Qazi, Shamona; Shah, Mehar Ali; Shoaib, Muhammad; Brona, Grzegorz; Cwiok, Mikolaj; Dominik, Wojciech; Doroba, Krzysztof; Kalinowski, Artur; Konecki, Marcin; Krolikowski, Jan; Bialkowska, Helena; Boimska, Bozena; Frueboes, Tomasz; Gokieli, Ryszard; Górski, Maciej; Kazana, Malgorzata; Nawrocki, Krzysztof; Romanowska-Rybinska, Katarzyna; Szleper, Michal; Wrochna, Grzegorz; Zalewski, Piotr; Almeida, Nuno; Bargassa, Pedrame; David Tinoco Mendes, Andre; Faccioli, Pietro; Ferreira Parracho, Pedro Guilherme; Gallinaro, Michele; Musella, Pasquale; Nayak, Aruna; Pela, Joao; Ribeiro, Pedro Quinaz; Seixas, Joao; Varela, Joao; Vischia, Pietro; Belotelov, Ivan; Bunin, Pavel; Golutvin, Igor; Kamenev, Alexey; Karjavin, Vladimir; Konoplyanikov, Viktor; Kozlov, Guennady; Lanev, Alexander; Malakhov, Alexander; Moisenz, Petr; Palichik, Vladimir; Perelygin, Victor; Savina, Maria; Shmatov, Sergey; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoli; Evstyukhin, Sergey; Golovtsov, Victor; Ivanov, Yury; Kim, Victor; Levchenko, Petr; Murzin, Victor; Oreshkin, Vadim; Smirnov, Igor; Sulimov, Valentin; Uvarov, Lev; Vavilov, Sergey; Vorobyev, Alexey; Vorobyev, Andrey; Andreev, Yuri; Dermenev, Alexander; Gninenko, Sergei; Golubev, Nikolai; Kirsanov, Mikhail; Krasnikov, Nikolai; Matveev, Viktor; Pashenkov, Anatoli; Toropin, Alexander; Troitsky, Sergey; Epshteyn, Vladimir; Erofeeva, Maria; Gavrilov, Vladimir; Kossov, Mikhail; Krokhotin, Andrey; Lychkovskaya, Natalia; Popov, Vladimir; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Vlasov, Evgueni; Zhokin, Alexander; Belyaev, Andrey; Boos, Edouard; Dubinin, Mikhail; Dudko, Lev; Ershov, Alexander; Gribushin, Andrey; Kodolova, Olga; Lokhtin, Igor; Markina, Anastasia; Obraztsov, Stepan; Perfilov, Maxim; Petrushanko, Sergey; Sarycheva, Ludmila; Savrin, Viktor; Snigirev, Alexander; Andreev, Vladimir; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Leonidov, Andrey; Mesyats, Gennady; Rusakov, Sergey V; Vinogradov, Alexey; Azhgirey, Igor; Bayshev, Igor; Bitioukov, Sergei; Grishin, Viatcheslav; Kachanov, Vassili; Konstantinov, Dmitri; Korablev, Andrey; Krychkine, Victor; Petrov, Vladimir; Ryutin, Roman; Sobol, Andrei; Tourtchanovitch, Leonid; Troshin, Sergey; Tyurin, Nikolay; Uzunian, Andrey; Volkov, Alexey; Adzic, Petar; Djordjevic, Milos; Ekmedzic, Marko; Krpic, Dragomir; Milosevic, Jovan; Aguilar-Benitez, Manuel; Alcaraz Maestre, Juan; Arce, Pedro; Battilana, Carlo; Calvo, Enrique; Cerrada, Marcos; Chamizo Llatas, Maria; Colino, Nicanor; De La Cruz, Begona; Delgado Peris, Antonio; Diez Pardos, Carmen; Domínguez Vázquez, Daniel; Fernandez Bedoya, Cristina; Fernández Ramos, Juan Pablo; Ferrando, Antonio; Flix, Jose; Fouz, Maria Cruz; Garcia-Abia, Pablo; Gonzalez Lopez, Oscar; Goy Lopez, Silvia; Hernandez, Jose M; Josa, Maria Isabel; Merino, Gonzalo; Puerta Pelayo, Jesus; Redondo, Ignacio; Romero, Luciano; Santaolalla, Javier; Senghi Soares, Mara; Willmott, Carlos; Albajar, Carmen; Codispoti, Giuseppe; de Trocóniz, Jorge F; Cuevas, Javier; Fernandez Menendez, Javier; Folgueras, Santiago; Gonzalez Caballero, Isidro; Lloret Iglesias, Lara; Piedra Gomez, Jonatan; Vizan Garcia, Jesus Manuel; Brochero Cifuentes, Javier Andres; Cabrillo, Iban Jose; Calderon, Alicia; Chuang, Shan-Huei; Duarte Campderros, Jordi; Felcini, Marta; Fernandez, Marcos; Gomez, Gervasio; Gonzalez Sanchez, Javier; Jorda, Clara; Lobelle Pardo, Patricia; Lopez Virto, Amparo; Marco, Jesus; Marco, Rafael; Martinez Rivero, Celso; Matorras, Francisco; Munoz Sanchez, Francisca Javiela; Rodrigo, Teresa; Rodríguez-Marrero, Ana Yaiza; Ruiz-Jimeno, Alberto; Scodellaro, Luca; Sobron Sanudo, Mar; Vila, Ivan; Vilar Cortabitarte, Rocio; Abbaneo, Duccio; Auffray, Etiennette; Auzinger, Georg; Baillon, Paul; Ball, Austin; Barney, David; Bernet, Colin; Bialas, Wojciech; Bianchi, Giovanni; Bloch, Philippe; Bocci, Andrea; Breuker, Horst; Bunkowski, Karol; Camporesi, Tiziano; Cerminara, Gianluca; Christiansen, Tim; Coarasa Perez, Jose Antonio; Curé, Benoît; D'Enterria, David; De Roeck, Albert; Di Guida, Salvatore; Dobson, Marc; Dupont-Sagorin, Niels; Elliott-Peisert, Anna; Frisch, Benjamin; Funk, Wolfgang; Gaddi, Andrea; Georgiou, Georgios; Gerwig, Hubert; Giffels, Manuel; Gigi, Dominique; Gill, Karl; Giordano, Domenico; Giunta, Marina; Glege, Frank; Gomez-Reino Garrido, Robert; Govoni, Pietro; Gowdy, Stephen; Guida, Roberto; Guiducci, Luigi; Hansen, Magnus; Harris, Philip; Hartl, Christian; Harvey, John; Hegner, Benedikt; Hinzmann, Andreas; Hoffmann, Hans Falk; Innocente, Vincenzo; Janot, Patrick; Kaadze, Ketino; Karavakis, Edward; Kousouris, Konstantinos; Lecoq, Paul; Lenzi, Piergiulio; Lourenco, Carlos; Maki, Tuula; Malberti, Martina; Malgeri, Luca; Mannelli, Marcello; Masetti, Lorenzo; Mavromanolakis, Georgios; Meijers, Frans; Mersi, Stefano; Meschi, Emilio; Moser, Roland; Mozer, Matthias Ulrich; Mulders, Martijn; Nesvold, Erik; Nguyen, Matthew; Orimoto, Toyoko; Orsini, Luciano; Palencia Cortezon, Enrique; Perez, Emmanuelle; Petrilli, Achille; Pfeiffer, Andreas; Pierini, Maurizio; Pimiä, Martti; Piparo, Danilo; Polese, Giovanni; Quertenmont, Loic; Racz, Attila; Reece, William; Rodrigues Antunes, Joao; Rolandi, Gigi; Rommerskirchen, Tanja; Rovelli, Chiara; Rovere, Marco; Sakulin, Hannes; Santanastasio, Francesco; Schäfer, Christoph; Schwick, Christoph; Segoni, Ilaria; Sharma, Archana; Siegrist, Patrice; Silva, Pedro; Simon, Michal; Sphicas, Paraskevas; Spiga, Daniele; Spiropulu, Maria; Stoye, Markus; Tsirou, Andromachi; Veres, Gabor Istvan; Vichoudis, Paschalis; Wöhri, Hermine Katharina; Worm, Steven; Zeuner, Wolfram Dietrich; Bertl, Willi; Deiters, Konrad; Erdmann, Wolfram; Gabathuler, Kurt; Horisberger, Roland; Ingram, Quentin; Kaestli, Hans-Christian; König, Stefan; Kotlinski, Danek; Langenegger, Urs; Meier, Frank; Renker, Dieter; Rohe, Tilman; Sibille, Jennifer; Bäni, Lukas; Bortignon, Pierluigi; Buchmann, Marco-Andrea; Casal, Bruno; Chanon, Nicolas; Chen, Zhiling; Deisher, Amanda; Dissertori, Günther; Dittmar, Michael; Dünser, Marc; Eugster, Jürg; Freudenreich, Klaus; Grab, Christoph; Lecomte, Pierre; Lustermann, Werner; Martinez Ruiz del Arbol, Pablo; Mohr, Niklas; Moortgat, Filip; Nägeli, Christoph; Nef, Pascal; Nessi-Tedaldi, Francesca; Pape, Luc; Pauss, Felicitas; Peruzzi, Marco; Ronga, Frederic Jean; Rossini, Marco; Sala, Leonardo; Sanchez, Ann - Karin; Sawley, Marie-Christine; Starodumov, Andrei; Stieger, Benjamin; Takahashi, Maiko; Tauscher, Ludwig; Thea, Alessandro; Theofilatos, Konstantinos; Treille, Daniel; Urscheler, Christina; Wallny, Rainer; Weber, Hannsjoerg Artur; Wehrli, Lukas; Weng, Joanna; Aguilo, Ernest; Amsler, Claude; Chiochia, Vincenzo; De Visscher, Simon; Favaro, Carlotta; Ivova Rikova, Mirena; Millan Mejias, Barbara; Otiougova, Polina; Robmann, Peter; Snoek, Hella; Verzetti, Mauro; Chang, Yuan-Hann; Chen, Kuan-Hsin; Kuo, Chia-Ming; Li, Syue-Wei; Lin, Willis; Liu, Zong-Kai; Lu, Yun-Ju; Mekterovic, Darko; Volpe, Roberta; Yu, Shin-Shan; Bartalini, Paolo; Chang, Paoti; Chang, You-Hao; Chang, Yu-Wei; Chao, Yuan; Chen, Kai-Feng; Dietz, Charles; Grundler, Ulysses; Hou, George Wei-Shu; Hsiung, Yee; Kao, Kai-Yi; Lei, Yeong-Jyi; Lu, Rong-Shyang; Majumder, Devdatta; Petrakou, Eleni; Shi, Xin; Shiu, Jing-Ge; Tzeng, Yeng-Ming; Wang, Minzu; Adiguzel, Aytul; Bakirci, Mustafa Numan; Cerci, Salim; Dozen, Candan; Dumanoglu, Isa; Eskut, Eda; Girgis, Semiray; Gokbulut, Gul; Hos, Ilknur; Kangal, Evrim Ersin; Karapinar, Guler; Kayis Topaksu, Aysel; Onengut, Gulsen; Ozdemir, Kadri; Ozturk, Sertac; Polatoz, Ayse; Sogut, Kenan; Sunar Cerci, Deniz; Tali, Bayram; Topakli, Huseyin; Uzun, Dilber; Vergili, Latife Nukhet; Vergili, Mehmet; Akin, Ilina Vasileva; Aliev, Takhmasib; Bilin, Bugra; Bilmis, Selcuk; Deniz, Muhammed; Gamsizkan, Halil; Guler, Ali Murat; Ocalan, Kadir; Ozpineci, Altug; Serin, Meltem; Sever, Ramazan; Surat, Ugur Emrah; Yalvac, Metin; Yildirim, Eda; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Gülmez, Erhan; Isildak, Bora; Kaya, Mithat; Kaya, Ozlem; Ozkorucuklu, Suat; Sonmez, Nasuf; Levchuk, Leonid; Bostock, Francis; Brooke, James John; Clement, Emyr; Cussans, David; Flacher, Henning; Frazier, Robert; Goldstein, Joel; Grimes, Mark; Heath, Greg P; Heath, Helen F; Kreczko, Lukasz; Metson, Simon; Newbold, Dave M; Nirunpong, Kachanon; Poll, Anthony; Senkin, Sergey; Smith, Vincent J; Williams, Thomas; Basso, Lorenzo; Bell, Ken W; Belyaev, Alexander; Brew, Christopher; Brown, Robert M; Cockerill, David JA; Coughlan, John A; Harder, Kristian; Harper, Sam; Jackson, James; Kennedy, Bruce W; Olaiya, Emmanuel; Petyt, David; Radburn-Smith, Benjamin Charles; Shepherd-Themistocleous, Claire; Tomalin, Ian R; Womersley, William John; Bainbridge, Robert; Ball, Gordon; Beuselinck, Raymond; Buchmuller, Oliver; Colling, David; Cripps, Nicholas; Cutajar, Michael; Dauncey, Paul; Davies, Gavin; Della Negra, Michel; Ferguson, William; Fulcher, Jonathan; Futyan, David; Gilbert, Andrew; Guneratne Bryer, Arlo; Hall, Geoffrey; Hatherell, Zoe; Hays, Jonathan; Iles, Gregory; Jarvis, Martyn; Karapostoli, Georgia; Lyons, Louis; Magnan, Anne-Marie; Marrouche, Jad; Mathias, Bryn; Nandi, Robin; Nash, Jordan; Nikitenko, Alexander; Papageorgiou, Anastasios; Pesaresi, Mark; Petridis, Konstantinos; Pioppi, Michele; Raymond, David Mark; Rogerson, Samuel; Rompotis, Nikolaos; Rose, Andrew; Ryan, Matthew John; Seez, Christopher; Sparrow, Alex; Tapper, Alexander; Tourneur, Stephane; Vazquez Acosta, Monica; Virdee, Tejinder; Wakefield, Stuart; Wardle, Nicholas; Wardrope, David; Whyntie, Tom; Barrett, Matthew; Chadwick, Matthew; Cole, Joanne; Hobson, Peter R; Khan, Akram; Kyberd, Paul; Leslie, Dawn; Martin, William; Reid, Ivan; Symonds, Philip; Teodorescu, Liliana; Turner, Mark; Hatakeyama, Kenichi; Liu, Hongxuan; Scarborough, Tara; Henderson, Conor; Avetisyan, Aram; Bose, Tulika; Carrera Jarrin, Edgar; Fantasia, Cory; Heister, Arno; St John, Jason; Lawson, Philip; Lazic, Dragoslav; Rohlf, James; Sperka, David; Sulak, Lawrence; Bhattacharya, Saptaparna; Cutts, David; Ferapontov, Alexey; Heintz, Ulrich; Jabeen, Shabnam; Kukartsev, Gennadiy; Landsberg, Greg; Luk, Michael; Narain, Meenakshi; Nguyen, Duong; Segala, Michael; Sinthuprasith, Tutanon; Speer, Thomas; Tsang, Ka Vang; Breedon, Richard; Breto, Guillermo; Calderon De La Barca Sanchez, Manuel; Caulfield, Matthew; Chauhan, Sushil; Chertok, Maxwell; Conway, John; Conway, Rylan; Cox, Peter Timothy; Dolen, James; Erbacher, Robin; Gardner, Michael; Houtz, Rachel; Ko, Winston; Kopecky, Alexandra; Lander, Richard; Mall, Orpheus; Miceli, Tia; Nelson, Randy; Pellett, Dave; Robles, Jorge; Rutherford, Britney; Searle, Matthew; Smith, John; Squires, Michael; Tripathi, Mani; Vasquez Sierra, Ricardo; Andreev, Valeri; Arisaka, Katsushi; Cline, David; Cousins, Robert; Duris, Joseph; Erhan, Samim; Everaerts, Pieter; Farrell, Chris; Hauser, Jay; Ignatenko, Mikhail; Jarvis, Chad; Plager, Charles; Rakness, Gregory; Schlein, Peter; Tucker, Jordan; Valuev, Vyacheslav; Weber, Matthias; Babb, John; Clare, Robert; Ellison, John Anthony; Gary, J William; Giordano, Ferdinando; Hanson, Gail; Jeng, Geng-Yuan; Liu, Hongliang; Long, Owen Rosser; Luthra, Arun; Nguyen, Harold; Paramesvaran, Sudarshan; Sturdy, Jared; Sumowidagdo, Suharyo; Wilken, Rachel; Wimpenny, Stephen; Andrews, Warren; Branson, James G; Cerati, Giuseppe Benedetto; Cittolin, Sergio; Evans, David; Golf, Frank; Holzner, André; Kelley, Ryan; Lebourgeois, Matthew; Letts, James; Macneill, Ian; Mangano, Boris; Padhi, Sanjay; Palmer, Christopher; Petrucciani, Giovanni; Pi, Haifeng; Pieri, Marco; Ranieri, Riccardo; Sani, Matteo; Sfiligoi, Igor; Sharma, Vivek; Simon, Sean; Sudano, Elizabeth; Tadel, Matevz; Tu, Yanjun; Vartak, Adish; Wasserbaech, Steven; Würthwein, Frank; Yagil, Avraham; Yoo, Jaehyeok; Barge, Derek; Bellan, Riccardo; Campagnari, Claudio; D'Alfonso, Mariarosaria; Danielson, Thomas; Flowers, Kristen; Geffert, Paul; Incandela, Joe; Justus, Christopher; Kalavase, Puneeth; Koay, Sue Ann; Kovalskyi, Dmytro; Krutelyov, Vyacheslav; Lowette, Steven; Mccoll, Nickolas; Pavlunin, Viktor; Rebassoo, Finn; Ribnik, Jacob; Richman, Jeffrey; Rossin, Roberto; Stuart, David; To, Wing; Vlimant, Jean-Roch; West, Christopher; Apresyan, Artur; Bornheim, Adolf; Bunn, Julian; Chen, Yi; Di Marco, Emanuele; Duarte, Javier; Gataullin, Marat; Ma, Yousi; Mott, Alexander; Newman, Harvey B; Rogan, Christopher; Timciuc, Vladlen; Traczyk, Piotr; Veverka, Jan; Wilkinson, Richard; Yang, Yong; Zhu, Ren-Yuan; Akgun, Bora; Carroll, Ryan; Ferguson, Thomas; Iiyama, Yutaro; Jang, Dong Wook; Jun, Soon Yung; Liu, Yueh-Feng; Paulini, Manfred; Russ, James; Vogel, Helmut; Vorobiev, Igor; Cumalat, John Perry; Dinardo, Mauro Emanuele; Drell, Brian Robert; Edelmaier, Christopher; Ford, William T; Gaz, Alessandro; Heyburn, Bernadette; Luiggi Lopez, Eduardo; Nauenberg, Uriel; Smith, James; Stenson, Kevin; Ulmer, Keith; Wagner, Stephen Robert; Zang, Shi-Lei; Agostino, Lorenzo; Alexander, James; Chatterjee, Avishek; Eggert, Nicholas; Gibbons, Lawrence Kent; Heltsley, Brian; Hopkins, Walter; Khukhunaishvili, Aleko; Kreis, Benjamin; Mirman, Nathan; Nicolas Kaufman, Gala; Patterson, Juliet Ritchie; Ryd, Anders; Salvati, Emmanuele; Sun, Werner; Teo, Wee Don; Thom, Julia; Thompson, Joshua; Vaughan, Jennifer; Weng, Yao; Winstrom, Lucas; Wittich, Peter; Biselli, Angela; Winn, Dave; Abdullin, Salavat; Albrow, Michael; Anderson, Jacob; Apollinari, Giorgio; Atac, Muzaffer; Bakken, Jon Alan; Bauerdick, Lothar AT; Beretvas, Andrew; Berryhill, Jeffrey; Bhat, Pushpalatha C; Bloch, Ingo; Burkett, Kevin; Butler, Joel Nathan; Chetluru, Vasundhara; Cheung, Harry; Chlebana, Frank; Cihangir, Selcuk; Cooper, William; Eartly, David P; Elvira, Victor Daniel; Esen, Selda; Fisk, Ian; Freeman, Jim; Gao, Yanyan; Gottschalk, Erik; Green, Dan; Gutsche, Oliver; Hanlon, Jim; Harris, Robert M; Hirschauer, James; Hooberman, Benjamin; Jensen, Hans; Jindariani, Sergo; Johnson, Marvin; Joshi, Umesh; Kilminster, Benjamin; Klima, Boaz; Kunori, Shuichi; Kwan, Simon; Leonidopoulos, Christos; Lincoln, Don; Lipton, Ron; Lykken, Joseph; Maeshima, Kaori; Marraffino, John Michael; Maruyama, Sho; Mason, David; McBride, Patricia; Miao, Ting; Mishra, Kalanand; Mrenna, Stephen; Musienko, Yuri; Newman-Holmes, Catherine; O'Dell, Vivian; Pivarski, James; Pordes, Ruth; Prokofyev, Oleg; Schwarz, Thomas; Sexton-Kennedy, Elizabeth; Sharma, Seema; Spalding, William J; Spiegel, Leonard; Tan, Ping; Taylor, Lucas; Tkaczyk, Slawek; Uplegger, Lorenzo; Vaandering, Eric Wayne; Vidal, Richard; Whitmore, Juliana; Wu, Weimin; Yang, Fan; Yumiceva, Francisco; Yun, Jae Chul; Acosta, Darin; Avery, Paul; Bourilkov, Dimitri; Chen, Mingshui; Das, Souvik; De Gruttola, Michele; Di Giovanni, Gian Piero; Dobur, Didar; Drozdetskiy, Alexey; Field, Richard D; Fisher, Matthew; Fu, Yu; Furic, Ivan-Kresimir; Gartner, Joseph; Goldberg, Sean; Hugon, Justin; Kim, Bockjoo; Konigsberg, Jacobo; Korytov, Andrey; Kropivnitskaya, Anna; Kypreos, Theodore; Low, Jia Fu; Matchev, Konstantin; Milenovic, Predrag; Mitselmakher, Guenakh; Muniz, Lana; Remington, Ronald; Rinkevicius, Aurelijus; Schmitt, Michael Houston; Scurlock, Bobby; Sellers, Paul; Skhirtladze, Nikoloz; Snowball, Matthew; Wang, Dayong; Yelton, John; Zakaria, Mohammed; Gaultney, Vanessa; Lebolo, Luis Miguel; Linn, Stephan; Markowitz, Pete; Martinez, German; Rodriguez, Jorge Luis; Adams, Todd; Askew, Andrew; Bochenek, Joseph; Chen, Jie; Diamond, Brendan; Gleyzer, Sergei V; Haas, Jeff; Hagopian, Sharon; Hagopian, Vasken; Jenkins, Merrill; Johnson, Kurtis F; Prosper, Harrison; Sekmen, Sezen; Veeraraghavan, Venkatesh; Weinberg, Marc; Baarmand, Marc M; Dorney, Brian; Hohlmann, Marcus; Kalakhety, Himali; Vodopiyanov, Igor; Adams, Mark Raymond; Anghel, Ioana Maria; Apanasevich, Leonard; Bai, Yuting; Bazterra, Victor Eduardo; Betts, Russell Richard; Callner, Jeremy; Cavanaugh, Richard; Dragoiu, Cosmin; Gauthier, Lucie; Gerber, Cecilia Elena; Hofman, David Jonathan; Khalatyan, Samvel; Kunde, Gerd J; Lacroix, Florent; Malek, Magdalena; O'Brien, Christine; Silkworth, Christopher; Silvestre, Catherine; Strom, Derek; Varelas, Nikos; Akgun, Ugur; Albayrak, Elif Asli; Bilki, Burak; Clarida, Warren; Duru, Firdevs; Griffiths, Scott; Lae, Chung Khim; McCliment, Edward; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony; Nachtman, Jane; Newsom, Charles Ray; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Ozok, Ferhat; Sen, Sercan; Tiras, Emrah; Wetzel, James; Yetkin, Taylan; Yi, Kai; Barnett, Bruce Arnold; Blumenfeld, Barry; Bolognesi, Sara; Bonato, Alessio; Fehling, David; Giurgiu, Gavril; Gritsan, Andrei; Guo, Zijin; Hu, Guofan; Maksimovic, Petar; Rappoccio, Salvatore; Swartz, Morris; Tran, Nhan Viet; Whitbeck, Andrew; Baringer, Philip; Bean, Alice; Benelli, Gabriele; Grachov, Oleg; Kenny Iii, Raymond Patrick; Murray, Michael; Noonan, Daniel; Sanders, Stephen; Stringer, Robert; Tinti, Gemma; Wood, Jeffrey Scott; Zhukova, Victoria; Barfuss, Anne-Fleur; Bolton, Tim; Chakaberia, Irakli; Ivanov, Andrew; Khalil, Sadia; Makouski, Mikhail; Maravin, Yurii; Shrestha, Shruti; Svintradze, Irakli; Gronberg, Jeffrey; Lange, David; Wright, Douglas; Baden, Drew; Boutemeur, Madjid; Calvert, Brian; Eno, Sarah Catherine; Gomez, Jaime; Hadley, Nicholas John; Kellogg, Richard G; Kirn, Malina; Kolberg, Ted; Lu, Ying; Marionneau, Matthieu; Mignerey, Alice; Peterman, Alison; Rossato, Kenneth; Rumerio, Paolo; Skuja, Andris; Temple, Jeffrey; Tonjes, Marguerite; Tonwar, Suresh C; Twedt, Elizabeth; Alver, Burak; Bauer, Gerry; Bendavid, Joshua; Busza, Wit; Butz, Erik; Cali, Ivan Amos; Chan, Matthew; Dutta, Valentina; Gomez Ceballos, Guillelmo; Goncharov, Maxim; Hahn, Kristan Allan; Kim, Yongsun; Klute, Markus; Lee, Yen-Jie; Li, Wei; Luckey, Paul David; Ma, Teng; Nahn, Steve; Paus, Christoph; Ralph, Duncan; Roland, Christof; Roland, Gunther; Rudolph, Matthew; Stephans, George; Stöckli, Fabian; Sumorok, Konstanty; Sung, Kevin; Velicanu, Dragos; Wenger, Edward Allen; Wolf, Roger; Wyslouch, Bolek; Xie, Si; Yang, Mingming; Yilmaz, Yetkin; Yoon, Sungho; Zanetti, Marco; Cooper, Seth; Cushman, Priscilla; Dahmes, Bryan; De Benedetti, Abraham; Franzoni, Giovanni; Gude, Alexander; Haupt, Jason; Kao, Shih-Chuan; Klapoetke, Kevin; Kubota, Yuichi; Mans, Jeremy; Pastika, Nathaniel; Rekovic, Vladimir; Rusack, Roger; Sasseville, Michael; Singovsky, Alexander; Tambe, Norbert; Turkewitz, Jared; Cremaldi, Lucien Marcus; Godang, Romulus; Kroeger, Rob; Perera, Lalith; Rahmat, Rahmat; Sanders, David A; Summers, Don; Avdeeva, Ekaterina; Bloom, Kenneth; Bose, Suvadeep; Butt, Jamila; Claes, Daniel R; Dominguez, Aaron; Eads, Michael; Jindal, Pratima; Keller, Jason; Kravchenko, Ilya; Lazo-Flores, Jose; Malbouisson, Helena; Malik, Sudhir; Snow, Gregory R; Baur, Ulrich; Godshalk, Andrew; Iashvili, Ia; Jain, Supriya; Kharchilava, Avto; Kumar, Ashish; Shipkowski, Simon Peter; Smith, Kenneth; Wan, Zongru; Alverson, George; Barberis, Emanuela; Baumgartel, Darin; Chasco, Matthew; Trocino, Daniele; Wood, Darien; Zhang, Jinzhong; Anastassov, Anton; Kubik, Andrew; Mucia, Nicholas; Odell, Nathaniel; Ofierzynski, Radoslaw Adrian; Pollack, Brian; Pozdnyakov, Andrey; Schmitt, Michael Henry; Stoynev, Stoyan; Velasco, Mayda; Won, Steven; Antonelli, Louis; Berry, Douglas; Brinkerhoff, Andrew; Hildreth, Michael; Jessop, Colin; Karmgard, Daniel John; Kolb, Jeff; Lannon, Kevin; Luo, Wuming; Lynch, Sean; Marinelli, Nancy; Morse, David Michael; Pearson, Tessa; Ruchti, Randy; Slaunwhite, Jason; Valls, Nil; Wayne, Mitchell; Wolf, Matthias; Ziegler, Jill; Bylsma, Ben; Durkin, Lloyd Stanley; Hill, Christopher; Killewald, Phillip; Kotov, Khristian; Ling, Ta-Yung; Puigh, Darren; Rodenburg, Marissa; Vuosalo, Carl; Williams, Grayson; Adam, Nadia; Berry, Edmund; Elmer, Peter; Gerbaudo, Davide; Halyo, Valerie; Hebda, Philip; Hegeman, Jeroen; Hunt, Adam; Laird, Edward; Lopes Pegna, David; Lujan, Paul; Marlow, Daniel; Medvedeva, Tatiana; Mooney, Michael; Olsen, James; Piroué, Pierre; Quan, Xiaohang; Raval, Amita; Saka, Halil; Stickland, David; Tully, Christopher; Werner, Jeremy Scott; Zuranski, Andrzej; Acosta, Jhon Gabriel; Huang, Xing Tao; Lopez, Angel; Mendez, Hector; Oliveros, Sandra; Ramirez Vargas, Juan Eduardo; Zatserklyaniy, Andriy; Alagoz, Enver; Barnes, Virgil E; Benedetti, Daniele; Bolla, Gino; Bortoletto, Daniela; De Mattia, Marco; Everett, Adam; Gutay, Laszlo; Hu, Zhen; Jones, Matthew; Koybasi, Ozhan; Kress, Matthew; Laasanen, Alvin T; Leonardo, Nuno; Maroussov, Vassili; Merkel, Petra; Miller, David Harry; Neumeister, Norbert; Shipsey, Ian; Silvers, David; Svyatkovskiy, Alexey; Vidal Marono, Miguel; Yoo, Hwi Dong; Zablocki, Jakub; Zheng, Yu; Guragain, Samir; Parashar, Neeti; Adair, Antony; Boulahouache, Chaouki; Cuplov, Vesna; Ecklund, Karl Matthew; Geurts, Frank JM; Padley, Brian Paul; Redjimi, Radia; Roberts, Jay; Zabel, James; Betchart, Burton; Bodek, Arie; Chung, Yeon Sei; Covarelli, Roberto; de Barbaro, Pawel; Demina, Regina; Eshaq, Yossof; Garcia-Bellido, Aran; Goldenzweig, Pablo; Gotra, Yury; Han, Jiyeon; Harel, Amnon; Miner, Daniel Carl; Petrillo, Gianluca; Sakumoto, Willis; Vishnevskiy, Dmitry; Zielinski, Marek; Bhatti, Anwar; Ciesielski, Robert; Demortier, Luc; Goulianos, Konstantin; Lungu, Gheorghe; Malik, Sarah; Mesropian, Christina; Arora, Sanjay; Atramentov, Oleksiy; Barker, Anthony; Chou, John Paul; Contreras-Campana, Christian; Contreras-Campana, Emmanuel; Duggan, Daniel; Ferencek, Dinko; Gershtein, Yuri; Gray, Richard; Halkiadakis, Eva; Hidas, Dean; Hits, Dmitry; Lath, Amitabh; Panwalkar, Shruti; Park, Michael; Patel, Rishi; Richards, Alan; Rose, Keith; Salur, Sevil; Schnetzer, Steve; Seitz, Claudia; Somalwar, Sunil; Stone, Robert; Thomas, Scott; Cerizza, Giordano; Hollingsworth, Matthew; Spanier, Stefan; Yang, Zong-Chang; York, Andrew; Eusebi, Ricardo; Flanagan, Will; Gilmore, Jason; Kamon, Teruki; Khotilovich, Vadim; Montalvo, Roy; Osipenkov, Ilya; Pakhotin, Yuriy; Perloff, Alexx; Roe, Jeffrey; Safonov, Alexei; Sakuma, Tai; Sengupta, Sinjini; Suarez, Indara; Tatarinov, Aysen; Toback, David; Akchurin, Nural; Damgov, Jordan; Dudero, Phillip Russell; Jeong, Chiyoung; Kovitanggoon, Kittikul; Lee, Sung Won; Libeiro, Terence; Roh, Youn; Sill, Alan; Volobouev, Igor; Wigmans, Richard; Appelt, Eric; Brownson, Eric; Engh, Daniel; Florez, Carlos; Gabella, William; Gurrola, Alfredo; Issah, Michael; Johns, Willard; Kurt, Pelin; Maguire, Charles; Melo, Andrew; Sheldon, Paul; Snook, Benjamin; Tuo, Shengquan; Velkovska, Julia; Arenton, Michael Wayne; Balazs, Michael; Boutle, Sarah; Conetti, Sergio; Cox, Bradley; Francis, Brian; Goadhouse, Stephen; Goodell, Joseph; Hirosky, Robert; Ledovskoy, Alexander; Lin, Chuanzhe; Neu, Christopher; Wood, John; Yohay, Rachel; Gollapinni, Sowjanya; Harr, Robert; Karchin, Paul Edmund; Kottachchi Kankanamge Don, Chamath; Lamichhane, Pramod; Mattson, Mark; Milstène, Caroline; Sakharov, Alexandre; Anderson, Michael; Bachtis, Michail; Belknap, Donald; Bellinger, James Nugent; Bernardini, Jacopo; Borrello, Laura; Carlsmith, Duncan; Cepeda, Maria; Dasu, Sridhara; Efron, Jonathan; Friis, Evan; Gray, Lindsey; Grogg, Kira Suzanne; Grothe, Monika; Hall-Wilton, Richard; Herndon, Matthew; Hervé, Alain; Klabbers, Pamela; Klukas, Jeffrey; Lanaro, Armando; Lazaridis, Christos; Leonard, Jessica; Loveless, Richard; Mohapatra, Ajit; Ojalvo, Isabel; Pierro, Giuseppe Antonio; Ross, Ian; Savin, Alexander; Smith, Wesley H; Swanson, Joshua

    2013-07-16

    Combined results are reported from searches for the standard model Higgs boson in proton-proton collisions at $\\sqrt{s}$=7 TeV in five Higgs boson decay modes: gamma pair, b-quark pair, tau lepton pair, W pair, and Z pair. The explored Higgs boson mass range is 110-600 GeV. The analysed data correspond to an integrated luminosity of 4.6-4.8 inverse femtobarns. The expected excluded mass range in the absence of the standard model Higgs boson is 118-543 GeV at 95% CL. The observed results exclude the standard model Higgs boson in the mass range 127-600 GeV at 95% CL, and in the mass range 129-525 GeV at 99% CL. An excess of events above the expected standard model background is observed at the low end of the explored mass range making the observed limits weaker than expected in the absence of a signal. The largest excess, with a local significance of 3.1 sigma, is observed for a Higgs boson mass hypothesis of 124 GeV. The global significance of observing an excess with a local significance greater than 3.1 sigm...

  7. Combined results of searches for the standard model Higgs boson in pp collisions at sqrt(s) = 7 TeV

    Energy Technology Data Exchange (ETDEWEB)

    Chatrchyan, Serguei [Yerevan Physics Inst. (Armenia); et al.

    2012-03-01

    Combined results are reported from searches for the standard model Higgs boson in proton-proton collisions at sqrt(s)=7 TeV in five Higgs boson decay modes: gamma pair, b-quark pair, tau lepton pair, W pair, and Z pair. The explored Higgs boson mass range is 110-600 GeV. The analysed data correspond to an integrated luminosity of 4.6-4.8 inverse femtobarns. The expected excluded mass range in the absence of the standard model Higgs boson is 118-543 GeV at 95% CL. The observed results exclude the standard model Higgs boson in the mass range 127-600 GeV at 95% CL, and in the mass range 129-525 GeV at 99% CL. An excess of events above the expected standard model background is observed at the low end of the explored mass range making the observed limits weaker than expected in the absence of a signal. The largest excess, with a local significance of 3.1 sigma, is observed for a Higgs boson mass hypothesis of 124 GeV. The global significance of observing an excess with a local significance greater than 3.1 sigma anywhere in the search range 110-600 (110-145) GeV is estimated to be 1.5 sigma (2.1 sigma). More data are required to ascertain the origin of this excess.

  8. [Poverty and Health: The Living Standard Approach as a Supplementary Concept to Measure Relative Poverty. Results from the German Socio-Economic Panel (GSOEP 2011)].

    Science.gov (United States)

    Pförtner, T-K

    2016-06-01

    A common indicator of the measurement of relative poverty is the disposable income of a household. Current research introduces the living standard approach as an alternative concept for describing and measuring relative poverty. This study compares both approaches with regard to subjective health status of the German population, and provides theoretical implications for the utilisation of the income and living standard approach in health research. Analyses are based on the German Socio-Economic Panel (GSOEP) from the year 2011 that includes 12 290 private households and 21106 survey members. Self-rated health was based on a subjective assessment of general health status. Income poverty is based on the equalised disposable income and is applied to a threshold of 60% of the median-based average income. A person will be denoted as deprived (inadequate living standard) if 3 or more out of 11 living standard items are lacking due to financial reasons. To calculate the discriminate power of both poverty indicators, descriptive analyses and stepwise logistic regression models were applied separately for men and women adjusted for age, residence, nationality, educational level, occupational status and marital status. The results of the stepwise regression revealed a stronger poverty-health relationship for the living standard indicator. After adjusting for all control variables and the respective poverty indicator, income poverty was statistically not significantly associated with a poor subjective health status among men (OR Men: 1.33; 95% CI: 1.00-1.77) and women (OR Women: 0.98; 95% CI: 0.78-1.22). In contrast, the association between deprivation and subjective health status was statistically significant for men (OR Men: 2.00; 95% CI: 1.57-2.52) and women (OR Women: 2.11; 95% CI: 1.76-2.64). The results of the present study indicate that the income and standard of living approach measure different dimensions of poverty. In comparison to the income approach, the living

  9. Does the perception of fairness and standard of care in the health system depend on the field of study? Results of an empirical analysis.

    Science.gov (United States)

    Damm, Kathrin; Prenzler, Anne; Zuchandke, Andy

    2014-04-12

    The main challenge in the context of health care reforms and priority setting is the establishment and/or maintenance of fairness and standard of care. For the political process and interdisciplinary discussion, the subjective perception of the health care system might even be as important as potential objective criteria. Of special interest are the perceptions of academic disciplines, whose representatives act as decision makers in the health care sector. The aim of this study is to explore and compare the subjective perception of fairness and standard of care in the German health care system among students of medicine, law, economics, philosophy, and religion. Between October 2011 and January 2012, we asked freshmen and advanced students of the fields mentioned above to participate in a paper and pencil survey. Prior to this, we formulated hypotheses. The data were analysed by micro econometric regression techniques. Data from 1,088 students were included in the study. Medical students, freshmen, and advanced students perceive the standard of care significantly as being better than non-medical students. Differences in the perception of fairness are not significant between the freshmen of the academic disciplines; however, they increase with the number of study terms. Besides the field of study, further variables such as gender and health status have a significant impact on perceptions. Our results show that there are differences in the perception of fairness and standard of care between academic disciplines, which might influence the interdisciplinary discussion on health care reforms and priority setting.

  10. Trans fat feeding results in higher serum alanine aminotransferase and increased insulin resistance compared with a standard murine high-fat diet.

    Science.gov (United States)

    Koppe, Sean W P; Elias, Marc; Moseley, Richard H; Green, Richard M

    2009-08-01

    Diets high in trans fats are associated with an increased risk of cardiovascular disease and components of the metabolic syndrome. The influence of these toxic fatty acids on the development of nonalcoholic fatty liver disease has not been significantly examined. Therefore, we sought to compare the effect of a murine diet high in trans fat to a standard high-fat diet that is devoid of trans fats but high in saturated fats. Male AKR/J mice were fed a calorically identical trans fat diet or standard high-fat diet for 10 days, 4 wk, and 8 wk. Serum alanine aminotransferase (ALT), lipid, insulin, and leptin levels were determined and the quantitative insulin-sensitivity check index (QUICKI) was calculated as a measure of insulin resistance. Additionally, hepatic triglyceride content and gene expression of several proinflammatory genes were assessed. By 8 wk, trans fat-fed mice exhibited higher ALT values than standard high-fat-fed mice (126 +/- 16 vs. 71 +/- 7 U/l, P Trans fat-fed mice also had increased insulin resistance compared with high-fat-fed mice at 4 and 8 wk with significantly higher insulin levels and lower QUICKI values. Additionally, hepatic interleukin-1beta (IL-1beta) gene expression was 3.6-fold higher at 4 wk (P trans fat-fed mice compared with standard high-fat-fed mice. Trans fat feeding results in higher ALT values, increased insulin resistance, and elevated IL-1beta levels compared with standard high-fat feeding.

  11. Standardized evaluation of tumor-infiltrating lymphocytes in breast cancer: results of the ring studies of the international immuno-oncology biomarker working group.

    Science.gov (United States)

    Denkert, Carsten; Wienert, Stephan; Poterie, Audrey; Loibl, Sibylle; Budczies, Jan; Badve, Sunil; Bago-Horvath, Zsuzsanna; Bane, Anita; Bedri, Shahinaz; Brock, Jane; Chmielik, Ewa; Christgen, Matthias; Colpaert, Cecile; Demaria, Sandra; Van den Eynden, Gert; Floris, Giuseppe; Fox, Stephen B; Gao, Dongxia; Ingold Heppner, Barbara; Kim, S Rim; Kos, Zuzana; Kreipe, Hans H; Lakhani, Sunil R; Penault-Llorca, Frederique; Pruneri, Giancarlo; Radosevic-Robin, Nina; Rimm, David L; Schnitt, Stuart J; Sinn, Bruno V; Sinn, Peter; Sirtaine, Nicolas; O'Toole, Sandra A; Viale, Giuseppe; Van de Vijver, Koen; de Wind, Roland; von Minckwitz, Gunter; Klauschen, Frederick; Untch, Michael; Fasching, Peter A; Reimer, Toralf; Willard-Gallo, Karen; Michiels, Stefan; Loi, Sherene; Salgado, Roberto

    2016-10-01

    Multiple independent studies have shown that tumor-infiltrating lymphocytes (TIL) are prognostic in breast cancer with potential relevance for response to immune-checkpoint inhibitor therapy. Although many groups are currently evaluating TIL, there is no standardized system for diagnostic applications. This study reports the results of two ring studies investigating TIL conducted by the International Working Group on Immuno-oncology Biomarkers. The study aim was to determine the intraclass correlation coefficient (ICC) for evaluation of TIL by different pathologists. A total of 120 slides were evaluated by a large group of pathologists with a web-based system in ring study 1 and a more advanced software-system in ring study 2 that included an integrated feedback with standardized reference images. The predefined aim for successful ring studies 1 and 2 was an ICC above 0.7 (lower limit of 95% confidence interval (CI)). In ring study 1 the prespecified endpoint was not reached (ICC: 0.70; 95% CI: 0.62-0.78). On the basis of an analysis of sources of variation, we developed a more advanced digital image evaluation system for ring study 2, which improved the ICC to 0.89 (95% CI: 0.85-0.92). The Fleiss' kappa value for international standardization project shows that reproducible evaluation of TIL is feasible in breast cancer. This opens the way for standardized reporting of tumor immunological parameters in clinical studies and diagnostic practice. The software-guided image evaluation approach used in ring study 2 may be of value as a tool for evaluation of TIL in clinical trials and diagnostic practice. The experience gained from this approach might be applicable to the standardization of other diagnostic parameters in histopathology.

  12. Cost-Effectiveness of Endovascular Femoropopliteal Intervention Using Drug-Coated Balloons Versus Standard Percutaneous Transluminal Angioplasty: Results From the IN.PACT SFA II Trial.

    Science.gov (United States)

    Salisbury, Adam C; Li, Haiyan; Vilain, Katherine R; Jaff, Michael R; Schneider, Peter A; Laird, John R; Cohen, David J

    2016-11-28

    The aim of this study was to evaluate the cost-effectiveness of drug-coated balloon (DCB) angioplasty versus standard percutaneous transluminal angioplasty (PTA). Recent trials have reported lower rates of target lesion revascularization with DCB angioplasty versus standard PTA. However, the cost-effectiveness of DCB angioplasty is unknown. A prospective economic study was performed alongside the IN.PACT SFA II (IN.PACT Admiral Drug-Coated Balloon vs. Standard Balloon Angioplasty for the Treatment of Superficial Femoral Artery [SFA] and Proximal Popliteal Artery [PPA]) trial, which randomized 181 patients with femoropopliteal disease to the IN.PACT DCB versus standard PTA. Resource use data were collected over 2-year follow-up, and costs were assigned using resource-based accounting and billing data. Health utilities were assessed using the EuroQol 5-dimensions questionnaire. Cost-effectiveness was assessed as cost per quality-adjusted life-year (QALY) gained using a decision-analytic model on the basis of empirical data from the trial assuming identical long-term mortality. Initial costs were $1,129 per patient higher with DCB angioplasty than standard PTA, driven by higher costs for the DCB itself. Between discharge and 24 months, target limb-related costs were $1,212 per patient lower with DCB angioplasty such that discounted 2-year costs were similar for the 2 groups ($11,277 vs. $11,359, p = 0.97), whereas QALYs tended to be greater among patients treated with DCBs (1.53 ± 0.44 vs. 1.47 ± 0.42, p = 0.40). The probability that DCB angioplasty is cost-effective compared with standard PTA was 70% using a threshold of $50,000 per QALY gained and 79% at a threshold of $150,000 per QALY gained. For patients with femoropopliteal disease, DCB angioplasty is associated with better 2-year outcomes and similar target limb-related costs compared with standard PTA. Formal cost-effectiveness analysis on the basis of these results suggests that use of the DCB angioplasty

  13. A computer program for lattice-dynamical evaluation of Debye-Waller factors and thermodynamic functions for minerals, starting from empirical force fields

    International Nuclear Information System (INIS)

    Pilati, T.; Dermartin, F.; Gramaccioli, C.M.

    1993-01-01

    A wide-purpose computer program has been written (Fortran) for lattice dynamical evaluation of crystallographic and thermodynamic properties of solids, especially minerals or inorganic substances.The program essentially consists of a routine affording first and second derivatives of energy with respect to mass weighted coordinates, properly modulated by a wave vector algorithm, so that diagonalization can immediately follow and arrive at frequencies, density of states, and eventually to thermodynamic functions and Debye-Waller parameters thorough an automatic Brillouin-zone sampling procedure. The input consists of crystallographic data (unit-cell parameters, space group symmetry operations, atomic coordinates), plus atomic charge and empirical parameters, such as force constants or non-bonded atom-atom interaction energy functions in almost any form. It is also possible to obtain the structure corresponding to the energy minimum, or even to work with partial rigid bodies, in order to reduce the order of the dynamical matrices. The program provides for automatic symmetry labelling of the vibrational modes, in order to compare them with the experimental data; there is possibility of improving the empirical functions through a minimization routine. Examples of application and transferability of force fields to a series of minerals are provided. (author)

  14. Effect of anharmonicity and Debye-Waller factor on the superconductivity of PdHsub(x) and PdDsub(x)

    International Nuclear Information System (INIS)

    Griessen, R.; Groot, D.G. de

    1983-01-01

    On the basis of existing superconducting tunnelling, neutron scattering, electrical resistivity and Raman scattering data and new thermal expansion, elastic moduli and point-contact spectroscopy data it is concluded that the anharmonicity of the proton (deuteron)-palladium potential is such that Msub(H)#betta#sub(H) 2 /(Msub(D)#betta#sub(D) 2 ) = 1.12 +- 0.05 Msub(H(D)) is the mass and #betta#sub(H(D)) the frequency of the vibration of hydrogen (deuterium). This anharmonicity is approximately 2 times too weak to reproduce the observed inverse isotope effect in the superconducting transition temperature of concentrated PdHsub(x) and PdDsub(x) alloys. Within a pseudopotential formalism it is shown that the Debye-Waller factor arising from the large zero-point amplitude of the interstitial hydrogen (deuterium) leads to a contribution to the inverse isotope effect in Tsub(c) which is as large as that of anharmonicity alone. (Auth.)

  15. Total knee arthroplasties performed with a mini-incision or a standard incision. Similar results at six months follow-up

    Directory of Open Access Journals (Sweden)

    Noriega-Fernandez Alfonso

    2010-02-01

    Full Text Available Abstract Background Minimal invasion surgery (MIS is a recent technique recommended for Total knee arthroplasty (TKA but demands an effort of the surgeons and the learning curve may be long. Methods Twenty six MIS-TKA were matched to 36 standard TKA with respect to age, sex, body mass index or preoperative score. All patients suffered from knee osteoarthritis, which had not improved with medical treatment and which presented a less than 10° deformity in the coronal and sagittal radiographic projections. At six months after the surgery a specific questionnaire was completed as well as the KSS (Knee Society rating scale, the generic short-form health questionnaire (SF-12 and a visual analogue scale (VAS. Results The MIS technique required more time of surgery (p Conclusions Minimal invasion surgery in total knee arthroplasty showed no improvement over a standard approach.

  16. Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children

    Directory of Open Access Journals (Sweden)

    Sibel Kocabeyoglu

    2013-01-01

    Full Text Available Aims : The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24-2 threshold program and standard automated perimetry (SAP using the Swedish interactive threshold algorithm (SITA-Standard 24-2 test. Materials and Methods: This prospective study included 55 healthy children without ocular or systemic disorders who underwent both SAP and frequency doubling technology (FDT perimetry visual field testing. Visual field test reliability indices, test duration, global indices (mean deviation [MD], and pattern standard deviation [PSD] were compared between the 2 tests using the Wilcoxon signed-rank test and paired t-test. The performance of the Humphrey field analyzer (HFA 24-2 SITA-standard and frequency-doubling technology Matrix 24-2 tests between genders were compared with Mann-Whitney U-test. Results: Fifty-five healthy children with a mean age of 12.2 ± 1.9 years (range from 8 years to 16 years were included in this prospective study. The test durations of SAP and FDT were similar (5.2 ± 0.5 and 5.1 ± 0.2 min, respectively, P = 0.651. MD and the PSD values obtained via FDT Matrix were significantly higher than those obtained via SAP (P < 0.001, and fixation losses and false negative errors were significantly less with SAP (P < 0.05. A weak positive correlation between the two tests in terms of MD (r = 0.352, P = 0.008 and PSD (r = 0.329, P = 0.014 was observed. Conclusion: Children were able to complete both the visual test algorithms successfully within 6 min. However, SAP testing appears to be associated with less depression of the visual field indices of healthy children. FDT Matrix and SAP should not be used interchangeably in the follow-up of children.

  17. Preliminary results of capecitabine metronomic chemotherapy in operable triple-negative breast cancer after standard adjuvant therapy – A single-arm phase II study

    Directory of Open Access Journals (Sweden)

    Hanan Shawky

    2014-12-01

    Conclusion: One year of capecitabine metronomic therapy preceded by standard adjuvant chemotherapy, is active and well-tolerated in TNBC patients previously treated with standard adjuvant chemotherapy.

  18. [Effects of standardized Myrtol in therapy of acute sinusitis--results of a double-blind, randomized multicenter study compared with placebo].

    Science.gov (United States)

    Federspil, P; Wulkow, R; Zimmermann, T

    1997-01-01

    In the management of non-purulent acute sinusitis, alpha adrenergic substances are administered topically and secretolytics systemically. Antibiotic therapy should be restricted to purulent forms. This study was designed to demonstrate the importance of the maintenance of permanent ventilation and drainage of the sinuses as a therapeutic concept. In a multicentric trial the efficacy and safety of myrtol standardized and another essential oil were investigated in 331 patients with acute sinusitis in comparison to placebo. Three hundred thirty patients were evaluated in an intent-to-treat-analysis and 291 patients remained for statistical analysis. The study was conducted in 16 centers in a double-blind, double-dummy, randomized design versus placebo. During an observation-period of 14 days the patients were treated for 6 +/- 2 days with the respective study medication. With respect to efficacy, both myrtol standardized and the other essential oil proved to be significantly superior to placebo. As to the tolerance, a slight advantage of myrtol standardized was demonstrated in comparison to the other verum substance. These results which do support the value of essential oils like myrtol as an effective treatment in acute, uncomplicated sinusitis instead of antibiotics as first choice, are confirmed by the existing literature.

  19. Diagnostic Pathway with Multiparametric Magnetic Resonance Imaging Versus Standard Pathway: Results from a Randomized Prospective Study in Biopsy-naïve Patients with Suspected Prostate Cancer.

    Science.gov (United States)

    Porpiglia, Francesco; Manfredi, Matteo; Mele, Fabrizio; Cossu, Marco; Bollito, Enrico; Veltri, Andrea; Cirillo, Stefano; Regge, Daniele; Faletti, Riccardo; Passera, Roberto; Fiori, Cristian; De Luca, Stefano

    2017-08-01

    An approach based on multiparametric magnetic resonance imaging (mpMRI) might increase the detection rate (DR) of clinically significant prostate cancer (csPCa). To compare an mpMRI-based pathway with the standard approach for the detection of prostate cancer (PCa) and csPCa. Between November 2014 and April 2016, 212 biopsy-naïve patients with suspected PCa (prostate specific antigen level ≤15 ng/ml and negative digital rectal examination results) were included in this randomized clinical trial. Patients were randomized into a prebiopsy mpMRI group (arm A, n=107) or a standard biopsy (SB) group (arm B, n=105). In arm A, patients with mpMRI evidence of lesions suspected for PCa underwent mpMRI/transrectal ultrasound fusion software-guided targeted biopsy (TB) (n=81). The remaining patients in arm A (n=26) with negative mpMRI results and patients in arm B underwent 12-core SB. The primary end point was comparison of the DR of PCa and csPCa between the two arms of the study; the secondary end point was comparison of the DR between TB and SB. The overall DRs were higher in arm A versus arm B for PCa (50.5% vs 29.5%, respectively; p=0.002) and csPCa (43.9% vs 18.1%, respectively; p<0.001). Concerning the biopsy approach, that is, TB in arm A, SB in arm A, and SB in arm B, the overall DRs were significantly different for PCa (60.5% vs 19.2% vs 29.5%, respectively; p<0.001) and for csPCa (56.8% vs 3.8% vs 18.1%, respectively; p<0.001). The reproducibility of the study could have been affected by the single-center nature. A diagnostic pathway based on mpMRI had a higher DR than the standard pathway in both PCa and csPCa. In this randomized trial, a pathway for the diagnosis of prostate cancer based on multiparametric magnetic resonance imaging (mpMRI) was compared with the standard pathway based on random biopsy. The mpMRI-based pathway had better performance than the standard pathway. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All

  20. Community health nurses' learning needs in relation to the Canadian community health nursing standards of practice: results from a Canadian survey.

    Science.gov (United States)

    Valaitis, Ruta K; Schofield, Ruth; Akhtar-Danesh, Noori; Baumann, Andrea; Martin-Misener, Ruth; Underwood, Jane; Isaacs, Sandra

    2014-01-01

    CANADIAN COMMUNITY HEALTH NURSES (CHNS) WORK IN DIVERSE URBAN, RURAL, AND REMOTE SETTINGS SUCH AS: public health units/departments, home health, community health facilities, family practices, and other community-based settings. Research into specific learning needs of practicing CHNs is sparsely reported. This paper examines Canadian CHNs learning needs in relation to the 2008 Canadian Community Health Nursing Standards of Practice (CCHN Standards). It answers: What are the learning needs of CHNs in Canada in relation to the CCHN Standards? What are differences in CHNs' learning needs by: province and territory in Canada, work setting (home health, public health and other community health settings) and years of nursing practice? Between late 2008 and early 2009 a national survey was conducted to identify learning needs of CHNs based on the CCHN Standards using a validated tool. Results indicated that CHNs had learning needs on 25 of 88 items (28.4%), suggesting CHNs have confidence in most CCHN Standards. Three items had the highest learning needs with mean scores > 0.60: two related to epidemiology (means 0.62 and 0.75); and one to informatics (application of information and communication technology) (mean = 0.73). Public health nurses had a greater need to know about "…evaluating population health promotion programs systematically" compared to home health nurses (mean 0.66 vs. 0.39, p learn "… advocating for healthy public policy…" than their more experienced peers (p = 0.0029). Also, NPs had a greater need to learn about "…using community development principles when engaging the individual/community in a consultative process" compared to RNs (p = 0.05). Many nurses were unsure if they applied foundational theoretical frameworks (i.e., the Ottawa Charter of Health Promotion, the Jakarta Declaration, and the Population Health Promotion Model) in practice. CHN educators and practice leaders need to consider these results in determining where to strengthen

  1. ValidatorDB: database of up-to-date validation results for ligands and non-standard residues from the Protein Data Bank.

    Science.gov (United States)

    Sehnal, David; Svobodová Vařeková, Radka; Pravda, Lukáš; Ionescu, Crina-Maria; Geidl, Stanislav; Horský, Vladimír; Jaiswal, Deepti; Wimmerová, Michaela; Koča, Jaroslav

    2015-01-01

    Following the discovery of serious errors in the structure of biomacromolecules, structure validation has become a key topic of research, especially for ligands and non-standard residues. ValidatorDB (freely available at http://ncbr.muni.cz/ValidatorDB) offers a new step in this direction, in the form of a database of validation results for all ligands and non-standard residues from the Protein Data Bank (all molecules with seven or more heavy atoms). Model molecules from the wwPDB Chemical Component Dictionary are used as reference during validation. ValidatorDB covers the main aspects of validation of annotation, and additionally introduces several useful validation analyses. The most significant is the classification of chirality errors, allowing the user to distinguish between serious issues and minor inconsistencies. Other such analyses are able to report, for example, completely erroneous ligands, alternate conformations or complete identity with the model molecules. All results are systematically classified into categories, and statistical evaluations are performed. In addition to detailed validation reports for each molecule, ValidatorDB provides summaries of the validation results for the entire PDB, for sets of molecules sharing the same annotation (three-letter code) or the same PDB entry, and for user-defined selections of annotations or PDB entries. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  2. Effects of Casting Size on Microstructure and Mechanical Properties of Spheroidal and Compacted Graphite Cast Irons: Experimental Results and Comparison with International Standards

    Science.gov (United States)

    Ceschini, L.; Morri, Alessandro; Morri, Andrea

    2017-05-01

    The aim of this research was to investigate the effects of casting size (10-210 mm) on the microstructure and mechanical properties of spheroidal (SGI) and compacted (CGI) graphite cast irons. A comparison of the experimental mechanical data with those specified by ISO standards is presented and discussed. The study highlighted that the microstructure and mechanical properties of SGI (also known as ductile or nodular cast iron) are more sensitive to casting size than CGI (also known as vermicular graphite cast irons). In particular, in both types of cast iron, hardness, yield strength and ultimate tensile strength decreased, with increasing casting size, by 27% in SGI and 17% in CGI. Elongation to failure showed, instead, an opposite trend, decreasing from 5 to 3% in CGI, while increasing from 5 to 11% in SGI. These results were related to different microstructures, the ferritic fraction being more sensitive to the casting size in SGI than CGI. Degeneration of spheroidal graphite was observed at casting size above 120 mm. The microstructural similarities between degenerated SGI and CGI suggested the proposal of a unified empirical constitutional law relating the most important microstructural parameters to the ultimate tensile strength. An outstanding result was also the finding that standard specifications underestimated the mechanical properties of both cast irons (in particular SGI) and, moreover, did not take into account their variation with casting size, at thicknesses over 60 mm.

  3. Results of a survey on applied quality standards in non-interventional studies among the members of the German Association of Research-based Pharmaceutical Companies

    Science.gov (United States)

    Hahn, Michael; Ruppert, Thorsten; Bethke, Thomas D.; Hundt, Ferdinand

    2010-01-01

    After the regulatory approval has been obtained, epidemiological studies are acknowledged scientific medical research methods for a new drug which provide additional knowledge about routine application of the drug in clinical daily routine. These studies are performed according to the recommendations of both international and national expert associations, the recommendations of the higher federal authorities in Germany and according to the recommendations of the associations of the pharmaceutical industry. Two surveys among the member companies of the Association of Research-based Pharmaceutical Companies investigated the status of the implementation of the recommendations in the years 2008 and 2010 and compared the results with each other. It could be shown that these recommendations were implemented successfully and were fully adhered to during the conduct of non-interventional studies in Germany. The recommendations define a quality standard which justifies a high level of confidence in the validity of the data collected and the results from these investigations. PMID:21063466

  4. Development of standard methods for activity measurement of natural radionuclides in waterworks as basis for dose and risk assessment—First results of an Austrian study

    International Nuclear Information System (INIS)

    Stietka, M.; Baumgartner, A.; Seidel, C.; Maringer, F.J.

    2013-01-01

    A comprehensive study with the aim to evaluate the risks due to radiation exposure for workers in water supply is conducted in 21 Austrian waterworks. The development of standard methods for the assessment of occupational exposure of water work staff is a part of this study. Preliminary results of this study show a wide range of Rn-222 activity concentration in waterworks with values from (28±10) Bq/m 3 to (38,000±4000) Bq/m 3 . Also seasonal variations of the Rn-222 activity concentration could be observed. - Highlights: • In this study operational exposure of water work staff was evaluated. • The Rn-222 concentration in indoor air in waterworks was measured for 1 year. • Results show a wide range of Rn-222 activity concentration in waterworks. • Seasonal variations of the Rn-222 activity concentration could be observed

  5. Effects of rapid versus standard HIV voluntary counselling and testing on receipt rate of HIV test results: a meta-analysis.

    Science.gov (United States)

    Wang, Yuan; Guo, Jian; Lu, Wenli

    2015-03-01

    Rapid HIV voluntary counselling and testing (RVCT) is an alternative method of standard HIV voluntary counselling and testing (SVCT). Less is known about whether RVCT improves the receipt rate of HIV test results among clients who seek HIV counselling and testing. We aimed to evaluate effectiveness of RVCT on result receipt rate. We conducted a comprehensive search of databases containing Medline, EBSCO, Web of science, and Cochrane library to identify studies published up to August 2012. Reviewers extracted information independently. Risk of bias was evaluated with Cochrane Collaboration's tool for assessing study quality. Five randomised controlled trials were included and analysed for the result receipt rate using a random-effects model. The pooled receipt rate of HIV test results in the RVCT was significantly higher than in the SVCT (RR = 1.74, 95% CI = 1.47-2.07). Our results suggest RVCT as a favourable method to increase the receipt of HIV test results. Only two included studies assessed the modification of risk behaviour after HIV-CT in a different manner; also, the sample size was small in the current meta-analysis. In future research, it is necessary to confirm the effect of RVCT on disinhibition of post-test risk behaviour. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  6. Complex carotid cavernous sinus fistulas Barrow type D: endovascular treatment via the ophthalmic vein, imaging control with standardized MRI, long-term results

    International Nuclear Information System (INIS)

    Struffert, T.; Grunwald, I.Q.; Reith, W.; Muecke, I.

    2007-01-01

    Purpose: Since feeding arteries from both the internal and external carotid artery are common, cavernous fistulas of Barrow type D are difficult to treat. Embolization using the transarterial approach is considered to be the standard therapy. However, it is often impossible to embolize feeders from the internal carotid artery. The transorbital approach after anterior orbitotomy through the ophthalmic vein is an alternative in this complex situation. The following reports our experience with three female patients who underwent transvenous embolization. Procedural success was documented using standardized MRI and clinical reevaluation. Materials and Methods: Three female patients between 57 and 78 years of age were diagnosed with carotid cavernous fistulas by conventional angiogram. All patients were suffering from exophthalmus and visual impairment. Two patients showed secondary glaucoma and diplopia. In one patient we performed a technically successful transarterial embolization using particles, but no relevant improvement of the patient's condition was seen. Transfemoral transvenous access via the sinus petrosus was not possible in any patient. All patients were then embolized via the ophthalmic vein using GDC detachable coils. All patients were clinically reevaluated by an ophthalmologist. Also a standardized MRI was performed for documentation. Follow-up was performed for the first patient for 32 months, for the second patient for 34 months and for the third patient for 50 months. Results: Transvenous embolization was technically successful in all three cases. Clinical symptoms disappeared rapidly. Postprocedural MRI showed a symmetric diameter of the ophthalmic vein. Venous congestion of the orbit caused by fatty tissue edema regressed completely. Contrast-enhanced magnetic resonance angiography showed normal arterial vessels without evidence of fistula. (orig.)

  7. Assessing standardization of molecular testing for non-small-cell lung cancer: results of a worldwide external quality assessment (EQA) scheme for EGFR mutation testing.

    Science.gov (United States)

    Patton, S; Normanno, N; Blackhall, F; Murray, S; Kerr, K M; Dietel, M; Filipits, M; Benlloch, S; Popat, S; Stahel, R; Thunnissen, E

    2014-07-15

    The external quality assurance (EQA) process aims at establishing laboratory performance levels. Leading European groups in the fields of EQA, Pathology, and Medical and Thoracic Oncology collaborated in a pilot EQA scheme for somatic epidermal growth factor receptor (EGFR) gene mutational analysis in non-small-cell lung cancer (NSCLC). EQA samples generated from cell lines mimicking clinical samples were provided to participating laboratories, each with a mock clinical case. Participating laboratories performed the analysis using their usual method(s). Anonymous results were assessed and made available to all participants. Two subsequent EQA rounds followed the pilot scheme. One hundred and seventeen labs from 30 countries registered and 91 returned results. Sanger sequencing and a commercial kit were the main methodologies used. The standard of genotyping was suboptimal, with a significant number of genotyping errors made. Only 72 out of 91 (72%) participants passed the EQA. False-negative and -positive results were the main sources of error. The quality of reports submitted was acceptable; most were clear, concise and easy to read. However, some participants reported the genotyping result in the absence of any interpretation and many obscured the interpretation required for clinical care. Even in clinical laboratories, the technical performance of genotyping in EGFR mutation testing for NSCLC can be improved, evident from a high level of diagnostic errors. Robust EQA can contribute to global optimisation of EGFR testing for NSCLC patients.

  8. Neutral kaon mixing beyond the Standard Model with nf=2+1 chiral fermions. Part 1: bare matrix elements and physical results

    International Nuclear Information System (INIS)

    Garron, Nicolas; Hudspith, Renwick J.; Lytle, Andrew T.

    2016-01-01

    We compute the hadronic matrix elements of the four-quark operators relevant for K 0 −K̄ 0 mixing beyond the Standard Model. Our results are from lattice QCD simulations with n f =2+1 flavours of domain-wall fermion, which exhibit continuum-like chiral-flavour symmetry. The simulations are performed at two different values of the lattice spacing (a∼0.08 and a∼0.11 fm) and with lightest unitary pion mass ∼300 MeV. For the first time, the full set of relevant four-quark operators is renormalised non-perturbatively through RI-SMOM schemes; a detailed description of the renormalisation procedure is presented in a companion paper. We argue that the intermediate renormalisation scheme is responsible for the discrepancies found by different collaborations. We also study different normalisations and determine the matrix elements of the relevant four-quark operators with a precision of ∼5% or better.

  9. Effect of intensive versus standard clinic-based hypertension management on ambulatory blood pressure – results from the SPRINT ambulatory blood pressure study

    Science.gov (United States)

    Drawz, Paul; Pajewski, Nicholas M.; Bates, Jeffrey T.; Bello, Natalie A.; Cushman, William C.; Dwyer, Jamie P.; Fine, Lawrence J.; Goff, David C.; Haley, William E.; Krousel-Wood, Marie; McWilliams, Andrew; Rifkin, Dena E.; Slinin, Yelena; Taylor, Addison; Townsend, Raymond; Wall, Barry; Wright, Jackson T.; Rahman, Mahboob

    2016-01-01

    The effect of clinic-based intensive hypertension treatment on ambulatory blood pressure (BP) is unknown. The goal of the Systolic Blood Pressure Intervention Trial (SPRINT) Ambulatory BP Ancillary Study was to evaluate the effect of intensive versus standard clinic-based BP targets on ambulatory BP. Ambulatory BP was obtained within 3 weeks of the 27 month study visit in 897 SPRINT participants. Intensive treatment resulted in lower clinic systolic BP (mean difference between groups = 16.0 mmHg (95% CI: 14.1 to 17.8 mmHg)), nighttime systolic BP (mean difference = 9.6 mmHg (95% CI: 7.7 to 11.5 mmHg)), daytime systolic BP (mean difference = 12.3 mmHg (95% CI: 10.6 to 13.9 mmHg)), and 24 hour systolic BP (mean difference = 11.2 mmHg (95% CI: 9.7 to 12.8 mmHg)). The night/day systolic BP ratio was similar between the intensive (0.92 ± 0.09) and standard treatment groups (0.91 ± 0.09). There was considerable lack of agreement within participants between clinic systolic BP and daytime ambulatory systolic BP with wide limits of agreement on Bland-Altman plots. In conclusion, targeting a systolic BP of less than 120 mmHg, as compared with less than 140 mmHg, resulted in lower nighttime, daytime, and 24 hour systolic BP, but did not change the night/day systolic BP ratio. Ambulatory BP monitoring may be required to assess the effect of targeted hypertension therapy on out of office BP. Further studies are needed to assess whether targeting hypertension therapy based on ambulatory BP improves clinical outcomes. PMID:27849563

  10. 'Standard' versus 'nose reference' electrode placement for measuring oVEMPs with air-conducted sound: Test-retest reliability and preliminary patient results.

    Science.gov (United States)

    Leyssens, Laura; Heinze, Barbara; Vinck, Bart; Van Ombergen, Angelique; Vanspauwen, Robby; Wuyts, Floris L; Maes, Leen K

    2017-02-01

    This study compared two electrode placements ('standard' versus 'nose reference' placement) for measuring oVEMPs, elicited by air-conducted 500Hz tone bursts. The test-retest reliability of both positions was evaluated and additionally both electrode placements were applied on a group of vestibular patients. Eighteen healthy volunteers (range of 20-25years) participated in the first part and were retested after one week for evaluation of the test-retest reliability. Eleven patients (range of 41-74years) with a variety of vestibular pathologies were tested once. In the normal group, the nose reference electrode placement resulted in significantly larger peak-to-peak amplitudes (ptest-retest reliability was observed with the nose reference configuration, as shown by the intraclass correlation coefficient (ICC), the coefficient of variation of the method error (CV ME ) and the minimal detectable differences (MDD). In the patient group, the same significant amplitude difference was found. Moreover, three patients presented with absent oVEMPs when recorded with the standard placement, whereas the nose reference placement could evoke a detectable oVEMP response. This study demonstrated that a nose reference electrode position results in larger oVEMP amplitudes and achieves a better reliability for the most important clinical parameters (amplitude and IOR). Our patient data substantiate the possible clinical benefit of this position, but further systematic patient verification is required. The nose reference electrode position facilitates the detection of generally very small oVEMP responses and shows a high test-retest reliability, showing promising potential for future use in the vestibular clinic. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  11. Effect of Intensive Versus Standard Clinic-Based Hypertension Management on Ambulatory Blood Pressure: Results From the SPRINT (Systolic Blood Pressure Intervention Trial) Ambulatory Blood Pressure Study.

    Science.gov (United States)

    Drawz, Paul E; Pajewski, Nicholas M; Bates, Jeffrey T; Bello, Natalie A; Cushman, William C; Dwyer, Jamie P; Fine, Lawrence J; Goff, David C; Haley, William E; Krousel-Wood, Marie; McWilliams, Andrew; Rifkin, Dena E; Slinin, Yelena; Taylor, Addison; Townsend, Raymond; Wall, Barry; Wright, Jackson T; Rahman, Mahboob

    2017-01-01

    The effect of clinic-based intensive hypertension treatment on ambulatory blood pressure (BP) is unknown. The goal of the SPRINT (Systolic Blood Pressure Intervention Trial) ambulatory BP ancillary study was to evaluate the effect of intensive versus standard clinic-based BP targets on ambulatory BP. Ambulatory BP was obtained within 3 weeks of the 27-month study visit in 897 SPRINT participants. Intensive treatment resulted in lower clinic systolic BP (mean difference between groups=16.0 mm Hg; 95% confidence interval, 14.1-17.8 mm Hg), nighttime systolic BP (mean difference=9.6 mm Hg; 95% confidence interval, 7.7-11.5 mm Hg), daytime systolic BP (mean difference=12.3 mm Hg; 95% confidence interval, 10.6-13.9 mm Hg), and 24-hour systolic BP (mean difference=11.2 mm Hg; 95% confidence interval, 9.7-12.8 mm Hg). The night/day systolic BP ratio was similar between the intensive (0.92±0.09) and standard-treatment groups (0.91±0.09). There was considerable lack of agreement within participants between clinic systolic BP and daytime ambulatory systolic BP with wide limits of agreement on Bland-Altman plots. In conclusion, targeting a systolic BP of hypertension therapy on out of office BP. Further studies are needed to assess whether targeting hypertension therapy based on ambulatory BP improves clinical outcomes. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01835249. © 2016 American Heart Association, Inc.

  12. Comparison of Analysis Results Between 2D/1D Synthesis and RAPTOR-M3G in the Korea Standard Nuclear Plant (KSNP)

    Science.gov (United States)

    Joung Lim, Mi; Maeng, Young Jae; Fero, Arnold H.; Anderson, Stanwood L.

    2016-02-01

    The 2D/1D synthesis methodology has been used to calculate the fast neutron (E > 1.0 MeV) exposure to the beltline region of the reactor pressure vessel. This method uses the DORT 3.1 discrete ordinates code and the BUGLE-96 cross-section library based on ENDF/B-VI. RAPTOR-M3G (RApid Parallel Transport Of Radiation-Multiple 3D Geometries) which performs full 3D calculations was developed and is based on domain decomposition algorithms, where the spatial and angular domains are allocated and processed on multi-processor computer architecture. As compared to traditional single-processor applications, this approach reduces the computational load as well as the memory requirement per processor. Both methods are applied to surveillance test results for the Korea Standard Nuclear Plant (KSNP)-OPR (Optimized Power Reactor) 1000 MW. The objective of this paper is to compare the results of the KSNP surveillance program between 2D/1D synthesis and RAPTOR-M3G. Each operating KSNP has a reactor vessel surveillance program consisting of six surveillance capsules located between the core and the reactor vessel in the downcomer region near the reactor vessel wall. In addition to the In-Vessel surveillance program, an Ex-Vessel Neutron Dosimetry (EVND) program has been implemented. In order to estimate surveillance test results, cycle-specific forward transport calculations were performed by 2D/1D synthesis and by RAPTOR-M3G. The ratio between measured and calculated (M/C) reaction rates will be discussed. The current plan is to install an EVND system in all of the Korea PWRs including the new reactor type, APR (Advanced Power Reactor) 1400 MW. This work will play an important role in establishing a KSNP-specific database of surveillance test results and will employ RAPTOR-M3G for surveillance dosimetry location as well as positions in the KSNP reactor vessel.

  13. Bridging the gap: Research and validation of the DST (Dynamic System Testing) performance test method for CE and ISO standards. Progress and preliminary results

    NARCIS (Netherlands)

    Naron, D.J.; Ree, B.G.C. van der; Rolloos, M.

    1998-01-01

    The Dynamic System Testing (DST) method is one of the methods chosen in the preliminary CEN/TC 312 European quality standards [1 ] to measure the energetic performance of Solar Domestic Hot Water (SDHW) systems. These European standards make a reference to the DST procedure as defined in the Draft

  14. FY 1999 Report on the technical results. Research and development project for creation of the quick-effect type international standards (Comprehensive surveys); 1999 nendo sokkogata kokusai hyojun sosei kenkyu kaihatsu jigyo seika hokokusho. Sogo chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Safety, environment protection and internationality are most important product qualities, and international standardization of product qualities and testing methods are essential for strengthening international competitiveness. Viewed from this angle, the R and D project is conducted to propose the international standards for the following 5 areas related to environment and safety, selected in expectation that the results could be obtained in short time for preparation of the international proposals; (1) standardization of the wireless IC tags for logistics management, (2) standardization of quality and testing methods of automobile fuels and lubricants, (3) research and development for international standards in the field of safety of machinery, (4) standardization of evaluation methods for electronic data security system, and (5) standardization for the safety of light emitting diodes. The results are obtained for preparation of the international standard drafts, interim or final. The activities are directed to promotion of international interchangeability of radio frequency identification (RFID) systems for area (1); to standardization of the systems for emergency stopping/controlling machines for the area (3), to improvement of security evaluation standards of existing information systems for the area (4), and to unification of the ISO/IEC safety standards for the area (5). (NEDO)

  15. Neutral kaon mixing beyond the Standard Model with n{sub f}=2+1 chiral fermions. Part 1: bare matrix elements and physical results

    Energy Technology Data Exchange (ETDEWEB)

    Garron, Nicolas [Theoretical Physics Division, Department of Mathematical Sciences, University of Liverpool,Brownlow Hill, Liverpool, L69 3BX (United Kingdom); Hudspith, Renwick J. [Department of Physics and Astronomy, York University,4700 Keele Street, Toronto, Ontario, M3J 1P3 (Canada); Lytle, Andrew T. [SUPA, School of Physics and Astronomy, University of Glasgow,University Avenue, Glasgow, G12 8QQ (United Kingdom); Collaboration: The RBC/UKQCD collaboration

    2016-11-02

    We compute the hadronic matrix elements of the four-quark operators relevant for K{sup 0}−K̄{sup 0} mixing beyond the Standard Model. Our results are from lattice QCD simulations with n{sub f}=2+1 flavours of domain-wall fermion, which exhibit continuum-like chiral-flavour symmetry. The simulations are performed at two different values of the lattice spacing (a∼0.08 and a∼0.11 fm) and with lightest unitary pion mass ∼300 MeV. For the first time, the full set of relevant four-quark operators is renormalised non-perturbatively through RI-SMOM schemes; a detailed description of the renormalisation procedure is presented in a companion paper. We argue that the intermediate renormalisation scheme is responsible for the discrepancies found by different collaborations. We also study different normalisations and determine the matrix elements of the relevant four-quark operators with a precision of ∼5% or better.

  16. Evaluation of the use of a standard input function for compartment analysis of [123I]iomazenil data. Factors influencing the quantitative results

    International Nuclear Information System (INIS)

    Seike, Yujiro; Hashikawa, Kazuo; Oku, Naohiko

    2004-01-01

    Adoption of standard input function (SIF) has been proposed for kinetic analysis of receptor binding potential (BP), instead of invasive frequent arterial samplings. The purpose of this study was to assess the SIP method in quantitative analysis of [ 123 I]iomazenil (IMZ), a central benzodiazepine antagonist, for SPECT. SPECT studies were performed on 10 patients with cerebrovascular disease or Alzheimer disease. Intermittent dynamic SPECT scans were performed from 0 to 201 min after IMZ-injection. BPs calculated from SIFs obtained from normal volunteers (BP s ) were compared with those of individual arterial samplings (BP O ). Good correlations were shown between BP O s and BP S s in the 9 subjects, but maximum BP S s were four times larger than the corresponding BP O s in one case. There were no abnormal laboratory data in this patient, but the relative arterial input count in the late period was higher than the SIF. Simulation studies with modified input functions revealed that height in the late period can produce significant errors in estimated BPs. These results suggested that the simplified method with one-point arterial sampling and SIF can not be applied clinically. One additional arterial sampling in the late period may be useful. (author)

  17. Standardized Expression of 18F-NAV4694 and 11C-PiB β-Amyloid PET Results with the Centiloid Scale.

    Science.gov (United States)

    Rowe, Christopher C; Jones, Gareth; Doré, Vincent; Pejoska, Svetlana; Margison, Laura; Mulligan, Rachel S; Chan, J Gordon; Young, Kenneth; Villemagne, Victor L

    2016-08-01

    A common quantitative output value for PET measures of β-amyloid (Aβ) binding across tracers and methods would allow better comparison of data across sites and application of universal diagnostic and prognostic values. A method has recently been developed that generates a unit of measurement called the centiloid. We applied this method to 2-[2-(18)F-fluoro-6-(methylamino)-3-pyridinyl]-1-benzofuran-5-ol ((18)F-NAV4694) and (11)C-Pittsburgh compound B ((11)C-PiB) Aβ images to derive the scaling factor required to express tracer binding in centiloids. Fifty-five participants, including 10 young controls (33 ± 7 y old), underwent both (11)C-PiB and (18)F-NAV4694 imaging no more than 3 mo apart, with the images acquired 50-70 min after tracer injection. The images were spatially normalized and analyzed using the standard centiloid method and regions (cortex and whole-cerebellum reference) downloaded from the Global Alzheimer Association Interactive Network website. SUV ratios (SUVRs) showed a strong correlation in tracer binding ((18)F-NAV4694 SUVR = 1.09 × (11)C-PiB SUVR - 0.08, R(2) = 0.99). The equation to convert (18)F-NAV4694 to centiloids [100 × ((18)F-NAV4694 SUVR - 1.028)/1.174] was similar to a published equation for (11)C-PiB [100 × ((11)C-PiB SUVR - 1.009)/1.067]. In the young controls, the variance ratio ((18)F-NAV4694 centiloid SD divided by (11)C-PiB centiloid SD) was 0.85. The results for both (11)C-PiB and (18)F-NAV4694 can now be expressed in centiloids, an important step that should allow better clinical and research use of Aβ imaging. The standard centiloid method also showed that (18)F-NAV4694 has slightly higher Aβ binding and lower variance than (11)C-PiB, important properties for detecting early Aβ deposition and change over time. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  18. Comparison of Analysis Results Between 2D/1D Synthesis and RAPTOR-M3G in the Korea Standard Nuclear Plant (KSNP

    Directory of Open Access Journals (Sweden)

    Lim Mi Joung

    2016-01-01

    Full Text Available The 2D/1D synthesis methodology has been used to calculate the fast neutron (E > 1.0 MeV exposure to the beltline region of the reactor pressure vessel. This method uses the DORT 3.1 discrete ordinates code and the BUGLE-96 cross-section library based on ENDF/B-VI. RAPTOR-M3G (RApid Parallel Transport Of Radiation-Multiple 3D Geometries which performs full 3D calculations was developed and is based on domain decomposition algorithms, where the spatial and angular domains are allocated and processed on multi-processor computer architecture. As compared to traditional single-processor applications, this approach reduces the computational load as well as the memory requirement per processor. Both methods are applied to surveillance test results for the Korea Standard Nuclear Plant (KSNP-OPR (Optimized Power Reactor 1000 MW. The objective of this paper is to compare the results of the KSNP surveillance program between 2D/1D synthesis and RAPTOR-M3G. Each operating KSNP has a reactor vessel surveillance program consisting of six surveillance capsules located between the core and the reactor vessel in the downcomer region near the reactor vessel wall. In addition to the In-Vessel surveillance program, an Ex-Vessel Neutron Dosimetry (EVND program has been implemented. In order to estimate surveillance test results, cycle-specific forward transport calculations were performed by 2D/1D synthesis and by RAPTOR-M3G. The ratio between measured and calculated (M/C reaction rates will be discussed. The current plan is to install an EVND system in all of the Korea PWRs including the new reactor type, APR (Advanced Power Reactor 1400 MW. This work will play an important role in establishing a KSNP-specific database of surveillance test results and will employ RAPTOR-M3G for surveillance dosimetry location as well as positions in the KSNP reactor vessel.

  19. Costs and cost-effectiveness of carotid stenting versus endarterectomy for patients at standard surgical risk: results from the Carotid Revascularization Endarterectomy Versus Stenting Trial (CREST).

    Science.gov (United States)

    Vilain, Katherine R; Magnuson, Elizabeth A; Li, Haiyan; Clark, Wayne M; Begg, Richard J; Sam, Albert D; Sternbergh, W Charles; Weaver, Fred A; Gray, William A; Voeks, Jenifer H; Brott, Thomas G; Cohen, David J

    2012-09-01

    from this controlled clinical trial demonstrate only trivial differences in overall healthcare costs and quality-adjusted life expectancy between the 2 strategies. If the CREST results can be replicated in clinical practice, these findings suggest that factors other than cost-effectiveness should be considered when deciding between treatment options for carotid artery stenosis in patients at standard risk for surgical complications. Clinical Trial Registration- URL: http://clinicaltrials.gov. Unique Identifier: NCT00004732.

  20. Exploration of pH-dependent behavior of the anion receptor pocket of subdomain IIA of HSA: determination of effective pocket charge using the Debye-Hückel limiting law.

    Science.gov (United States)

    Bolel, Priyanka; Datta, Shubhashis; Mahapatra, Niharendu; Halder, Mintu

    2014-01-09

    Protein-ligand electrostatic interaction can be looked upon as ion receptor-ligand interaction, and the binding cavity of protein can be either an anion or cation receptor depending on the charge of the guest. Here we focus on the exploration of pH-modulated binding of a number of anionic ligands, specific to the subdomain IIA cavity of HSA, such as carmoisine, tartrazine, cochineal red, and warfarin. The logarithm of the binding constant is found to vary linearly with the square-root of ionic strength, indicating applicability of the Debye-Hückel limiting law to protein-ligand electrostatic binding equilibrium, and concludes that the subdomain IIA cavity is an anion receptor. The present approach is very unique that one can calculate the effective charge of the protein-based anion receptor pocket, and the calculated charge has been found to vary between +1 and +3 depending on the pH and ligand itself. The study also indicates that in such cases of specific ligand binding the pocket charge rather than the overall or surface charge of the macromolecule seems to have a paramount role in determining the strength of interaction. For the first time, it is demonstrated that the Debye-Hückel interionic interaction model can be successfully applied to understand the protein-based receptor-ligand electrostatic interaction in general.

  1. Drug-eluting balloon versus standard balloon angioplasty for infrapopliteal arterial revascularization in critical limb ischemia: 12-month results from the IN.PACT DEEP randomized trial.

    Science.gov (United States)

    Zeller, Thomas; Baumgartner, Iris; Scheinert, Dierk; Brodmann, Marianne; Bosiers, Marc; Micari, Antonio; Peeters, Patrick; Vermassen, Frank; Landini, Mario; Snead, David B; Kent, K Craig; Rocha-Singh, Krishna J

    2014-10-14

    Drug-eluting balloons (DEB) may reduce infrapopliteal restenosis and reintervention rates versus percutaneous transluminal angioplasty (PTA) and improve wound healing/limb preservation. The goal of this clinical trial was to assess the efficacy and safety of IN.PACT Amphirion drug-eluting balloons (IA-DEB) compared to PTA for infrapopliteal arterial revascularization in patients with critical limb ischemia (CLI). Within a prospective, multicenter, randomized, controlled trial with independent clinical event adjudication and angiographic and wound core laboratories 358 CLI patients were randomized 2:1 to IA-DEB or PTA. The 2 coprimary efficacy endpoints through 12 months were clinically driven target lesion revascularization (CD-TLR) and late lumen loss (LLL). The primary safety endpoint through 6 months was a composite of all-cause mortality, major amputation, and CD-TLR. Clinical characteristics were similar between the 2 groups. Significant baseline differences between the IA-DEB and PTA arms included mean lesion length (10.2 cm vs. 12.9 cm; p = 0.002), impaired inflow (40.7% vs. 28.8%; p = 0.035), and previous target limb revascularization (32.2% vs. 21.8%; p = 0.047). Primary efficacy results of IA-DEB versus PTA were CD-TLR of 9.2% versus 13.1% (p = 0.291) and LLL of 0.61 ± 0.78 mm versus 0.62 ± 0.78 mm (p = 0.950). Primary safety endpoints were 17.7% versus 15.8% (p = 0.021) and met the noninferiority hypothesis. A safety signal driven by major amputations through 12 months was observed in the IA-DEB arm versus the PTA arm (8.8% vs. 3.6%; p = 0.080). In patients with CLI, IA-DEB had comparable efficacy to PTA. While primary safety was met, there was a trend towards an increased major amputation rate through 12 months compared to PTA. (Study of IN.PACT Amphirion™ Drug Eluting Balloon vs. Standard PTA for the Treatment of Below the Knee Critical Limb Ischemia [INPACT-DEEP]; NCT00941733). Copyright © 2014 American College of Cardiology Foundation. Published

  2. Common Pressures, Same Results? Recent Reforms in Professional Standards and Competences in Teacher Education for Secondary Teachers in England, France and Germany

    Science.gov (United States)

    Page, Tina M.

    2015-01-01

    Over the last decade, the introduction of professional standards and competences in initial teacher education for secondary teachers in England, France and Germany has provided the cornerstone of education reform in all three countries. The precise number and specific content of a measurable set of skills for teachers have offered challenges for…

  3. Who Are the Students Who May Qualify for an Alternate Assessment Based on Modified Academic Achievement Standards (AA-MAS)?: Focus Group Results. Synthesis Report 79

    Science.gov (United States)

    Berndt, Sandra; Ebben, Barbara; Kubinski, Eva; Sim, Grant; Liu, Kristin; Lazarus, Sheryl; Thurlow, Martha; Christian, Elizabeth

    2011-01-01

    Beginning in 2007, federal regulations to two major education laws gave state departments of education the option to develop an alternate assessment based on modified achievement standards (AA-MAS) for some students with disabilities. The regulations stated that the AA-MAS was intended for students who were being instructed in the grade-level…

  4. Does the Responsive Classroom Approach Affect the Use of Standards-Based Mathematics Teaching Practices?: Results from a Randomized Controlled Trial

    Science.gov (United States)

    Ottmar, Erin R.; Rimm-Kaufman, Sara E.; Berry, Robert Q.; Larsen, Ross A.

    2013-01-01

    This study highlights the connections between two facets of teachers' skills--those supporting teachers' mathematical instructional interactions and those underlying social interactions within the classroom. The impact of the Responsive Classroom (RC) approach and use of RC practices on the use of standards-based mathematics teaching practices was…

  5. Fiscal 1997 report on the results of the international standardization R and D. International standards for computers/manikins; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Computer manikin ni kansuru kokusai hyojun kikaku

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    Through the development of computer manikins (CM) which assess human adaptability to products and environments, a draft for international standardization was worked out to propose to ISO. A draft for the international standardization was presented to ISO through a development of `a structure model` changing based on human attributes, a study of `a motion model` enabling changes in posture and movement, a study of `an evaluation model` evaluating attainment ranges and ecodynamic loads, and a development of `computer functions` realizing the above-mentioned functions. The development of CM having the following characteristics: a function to reproduce `the structure model` based on the ISO7250 human body dimensional measuring values which were regulated in items for the human body dimensional measuring, a function to change posture/movement based on the joint movable range data, a function to evaluate geometrical human adaptability such as attainment ranges. As a plug-in to Autodesk Mechanical Desktop 2.0, the above-mentioned functions were realized, and the modular structure platform was constructed which enables the wide-range cross-industry option and functional expansion by the advance of CM. 7 refs., 41 figs., 18 tabs.

  6. An alternative explanation of the change in T-dependence of the effective Debye-Waller factor at T{sub c} or T{sub B}

    Energy Technology Data Exchange (ETDEWEB)

    Ngai, K. L. [Dipartimento di Fisica, Università di Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); CNR-IPCF, Largo Bruno Pontecorvo 3, I-56127 Pisa (Italy); Habasaki, J. [Tokyo Institute of Technology, Yokohama 226-8502 (Japan)

    2014-09-21

    The cusp-like temperature dependence of the Debye-Waller factor or non-ergodicity parameter f{sub Q}(T) at some temperature T{sub c} above T{sub g} found by experiments in several fragile glassformers has been considered as critical evidence for validity of the ideal Mode Coupling Theory (MCT). A comprehensive review of experimental data of f{sub Q}(T) and beyond brings out various problems of the MCT predictions. For example, the molten salt, 0.4Ca(NO{sub 3}){sub 2}-0.6KNO{sub 3} (CKN), was the first glassformer measured by neutron scattering to verify the cusp-like behavior of f{sub Q}(T) at T{sub c} predicted by ideal MCT. While the fits of the other scaling laws of MCT to viscosity, light scattering, and dielectric relaxation data all give T{sub c} in the range from 368 to 375 K, there is no evidence of cusp-like behavior of f{sub Q}(T) at T{sub c} from more accurate neutron scattering data obtained later on by Mezei and Russina [J. Phys.: Condens. Matter 11, A341 (1999)] at temperatures below 400 K. In several molecular glass-formers, experiments have found at temperatures below T{sub c} that [1−f{sub Q}(T)] is manifested as nearly constant loss (NCL) in the frequency dependent susceptibility. The NCL persists down to below T{sub g} and is not predicted by the ideal MCT. No clear evidence of the change of T-dependence of f{sub Q}(T) at any T{sub c} was found in intermediate and strong glassformers, although ideal MCT does not distinguish fragile and strong glassformers in predicting the critical behavior of f{sub Q}(T) a priori. Experiments found f{sub Q}(T) changes T-dependence not only at T{sub c} but also at the glass transition temperature T{sub g}. The changes of T-dependence of f{sub Q}(T) at T{sub c} and T{sub g} are accompanied by corresponding changes of dynamic variables and thermodynamic quantities at T{sub B} ≈ T{sub c} and at T{sub g}. The dynamic variables include the relaxation time τ{sub α}(T), the non-exponentiality parameter n(T), and

  7. Fiscal 1997 report on the results of the international standardization R and D. Robot control system; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Robot seigyo system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    R and D of the robot control system was conducted in the following items: 1) integrated open control system, 2) remote control robot manipulation language, 3) human factor robot use built-in LAN system, 4) built-in actuator driver. In 1), there were some problems to be pointed out around the system, but the effectiveness was confirmed as system architecture of each verification item. In 2), development/design were made of RCML(R-Cube Manipulation Language) as a remote robot manipulation language, telecommunication protocol, and the experimental system, and the international standardization was targeted. In 3), the R and D was conducted of the realtime telecommunication protocol which clears the standards for the distributed control required for construction of human factor robot and the advanced realtime micro-controller, ULSI, which is the one that the protocol was made IC. In 4), an intelligent connector for built-in actuator was developed which enables saving of wiring in robot system and plug-in connection. 13 refs., 186 figs., 53 tabs.

  8. An international effort towards developing standards for best practices in analysis, interpretation and reporting of clinical genome sequencing results in the CLARITY Challenge

    DEFF Research Database (Denmark)

    Brownstein, Catherine A; Beggs, Alan H; Homer, Nils

    2014-01-01

    and reporting. The CLARITY Challenge was designed to spur convergence in methods for diagnosing genetic disease starting from clinical case history and genome sequencing data. DNA samples were obtained from three families with heritable genetic disorders and genomic sequence data were donated by sequencing......Background : There is tremendous potential for genome sequencing to improve clinical diagnosis and care once it becomes routinely accessible, but this will require formalizing research methods into clinical best practices in the areas of sequence data generation, analysis, interpretation......, demonstrating a need for consistent fine-tuning of the generally accepted methods. There was greater diversity of the final clinical report content and in the patient consenting process, demonstrating that these areas require additional exploration and standardization. Conclusions : The CLARITY Challenge...

  9. Compendium of Single Event Effects (SEE) Test Results for COTS and Standard Electronics for Low Earth Orbit and Deep Space Applications

    Science.gov (United States)

    Reddell, Brandon; Bailey, Chuck; Nguyen, Kyson; O'Neill, Patrick; Gaza, Razvan; Patel, Chirag; Cooper, Jaime; Kalb, Theodore

    2017-01-01

    We present the results of SEE testing with high energy protons and with low and high energy heavy ions. This paper summarizes test results for components considered for Low Earth Orbit and Deep Space applications.

  10. Literacy, Numeracy, and Problem Solving in Technology-Rich Environments among U.S. Adults: Results from the Program for the International Assessment of Adult Competencies 2012. Appendix D: Standard Error Tables. First Look. NCES 2014-008

    Science.gov (United States)

    National Center for Education Statistics, 2013

    2013-01-01

    This paper provides Appendix D, Standard Error tables, for the full report, entitled. "Literacy, Numeracy, and Problem Solving in Technology-Rich Environments among U.S. Adults: Results from the Program for the International Assessment of Adult Competencies 2012. First Look. NCES 2014-008." The full report presents results of the Program…

  11. Presence of a novel DNA methylation enzyme in methicillin-resistant Staphylococcus aureus isolates associated with pig farming leads to uninterpretable results in standard pulsed-field gel electrophoresis analysis.

    NARCIS (Netherlands)

    Bens, C.C.; Voss, A.; Klaassen, C.H.W.

    2006-01-01

    Genomic DNA from methicillin-resistant Staphylococcus aureus isolates recovered from pigs and their caretakers proved resistant to SmaI digestion, leading to uninterpretable results in standard pulsed-field gel electrophoresis. This is the result of a yet unknown restriction/methylation system in

  12. Presence of a Novel DNA Methylation Enzyme in Methicillin-Resistant Staphylococcus aureus Isolates Associated with Pig Farming Leads to Uninterpretable Results in Standard Pulsed-Field Gel Electrophoresis Analysis

    OpenAIRE

    Bens, Corina C. P. M.; Voss, Andreas; Klaassen, Corné H. W.

    2006-01-01

    Genomic DNA from methicillin-resistant Staphylococcus aureus isolates recovered from pigs and their caretakers proved resistant to SmaI digestion, leading to uninterpretable results in standard pulsed-field gel electrophoresis. This is the result of a yet unknown restriction/methylation system in the genus Staphylococcus with the recognition sequence CCNGG.

  13. Randomized, Multicenter Trial on the Effect of Radiation Therapy on Plantar Fasciitis (Painful Heel Spur) Comparing a Standard Dose With a Very Low Dose: Mature Results After 12 Months' Follow-Up

    International Nuclear Information System (INIS)

    Niewald, Marcus; Seegenschmiedt, M. Heinrich; Micke, Oliver; Graeber, Stefan; Muecke, Ralf; Schaefer, Vera; Scheid, Christine; Fleckenstein, Jochen; Licht, Norbert; Ruebe, Christian

    2012-01-01

    Purpose: To conduct a randomized trial of radiation therapy for painful heel spur, comparing a standard dose with a very low dose. Methods and Materials: Sixty-six patients were randomized to receive radiation therapy either with a total dose of 6.0 Gy applied in 6 fractions of 1.0 Gy twice weekly (standard dose) or with a total dose of 0.6 Gy applied in 6 fractions of 0.1 Gy twice weekly (low dose). In all patients lateral opposing 4- to 6-MV photon beams were used. The results were measured using a visual analogue scale, the Calcaneodynia score, and the SF12 health survey. The fundamental phase of the study ended after 3 months, and the follow-up was continued up to 1 year. Patients with insufficient pain relief after 3 months were offered reirradiation with the standard dosage at any time afterward. Results: Of 66 patients, 4 were excluded because of withdrawal of consent or screening failures. After 3 months the results in the standard arm were highly significantly superior compared with those in the low-dose arm (visual analogue scale, P=.001; Calcaneodynia score, P=.027; SF12, P=.045). The accrual of patients was stopped at this point. Further evaluation after 12 months' follow-up showed the following results: (1) highly significant fewer patients were reirradiated in the standard arm compared with the low-dose arm (P<.001); (2) the results of patients in the low-dose arm who were reirradiated were identical to those in the standard arm not reirradiated (reirradiation as a salvage therapy if the lower dose was ineffective); (3) patients experiencing a favorable result after 3 months showed this even after 12 months, and some results even improved further between 3 and 12 months. Conclusions: This study confirms the superior analgesic effect of radiation therapy with 6-Gy doses on painful heel spur even for a longer time period of at least 1 year.

  14. Correlation between apparent diffusion coefficients and standardized uptake values in hybrid {sup 18}F-FDG PET/MR: Preliminary results in rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye [Dept. of Nuclear Medicine, Kyungpook National University Hospital, Daegu (Korea, Republic of); Cho, Ihn Ho; Chun, Kyung Ah; Kong, Eun Jung; Kwon, Sang Don; Kim, Jae Hwang [Yeungnam University Hospital, Daegu (Korea, Republic of)

    2016-06-15

    Fluorine-18-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography (PET) and diffusion-weighted magnetic resonance imaging (DWI) share the same role in clinical oncology and it is feasible to obtain the standardized uptake value (SUV) and apparent diffusion coefficient (ADC) simultaneously by emerging the hybrid positron emission tomography/magnetic resonance (PET/MR). This study investigated the correlation between the ADCs of rectal cancer lesions and their SUVs derived from hybrid PET/MR. Nine patients with histologically proven rectal adenocarcinoma (5 men, 4 women; mean age, 70 ± 15.91 years) underwent torso {sup 18}F-FDG PET/CT and regional hybrid {sup 18}F-FDG PET/MR sequentially. A fixed threshold value of 40 % of maximum uptake was used to determine tumor volume of interest (VOI) on PET image; SUV{sub max}, SUV{sub peak}, and SUV{sub mean} were calculated automatically. A single freehand region of interest (ROI) was drawn on high b-value (b1000) DWI image and copied to corresponding ADC map to determine the ADCmean of rectal cancer lesion. Spearman'rank correlation coefficient (ρ) was calculated to determine the correlation between SUVs and ADC values. SUV{sub max}, SUV{sub peak}, and SUV{sub mean} derived by hybrid PET/MR were 12.35 ± 4.66 (mean ± standard deviation), 9.66  ± 3.15 and 7.41 ± 2.54, respectively. The ADCmean value of rectal cancer lesions was 1.02 ± 0.08 × 10{sup -3}mm{sup 2}/s. ADCmean was significantly and inversely correlated with SUV values (SUV{sub max}, ρ = -0.95, p < 0.001; SUV{sub peak}, ρ = -0.93, p < 0.001; SUV{sub mean}, ρ = -0.91, p = 0.001). This preliminary hybrid PET/MR study demonstrates a significant inverse correlation exists between metabolic activity on {sup 18}F-FDG PET and water diffusion on DWI in rectal cancer.

  15. Is Whole-Body Computed Tomography the Standard Work-up for Severely-Injured Children? Results of a Survey among German Trauma Centers.

    Science.gov (United States)

    Bayer, J; Reising, K; Kuminack, K; Südkamp, N P; Strohm, P C

    2015-01-01

    Whole-body computed tomography is accepted as the standard procedure in the primary diagnostic of polytraumatised adults in the emergency room. Up to now there is still controversial discussion about the same algorithm in the primary diagnostic of children. The aim of this study was to survey the participation of German trauma-centres in the care of polytraumatised children and the hospital dependant use of whole-body computed tomography for initial patient work-up. A questionnaire was mailed to every Department of Traumatology registered in the DGU (German Trauma Society) databank. We received 60,32% of the initially sent questionnaires and after applying exclusion criteria 269 (53,91%) were applicable to statistical analysis. In the three-tiered German hospital system no statistical difference was seen in the general participation of children polytrauma care between hospitals of different tiers (p = 0.315). Even at the lowest hospital level 69,47% of hospitals stated to participate in polytrauma care for children, at the intermediate and highest level hospitals 91,89% and 95,24% stated to be involved in children polytrauma care, respectively. Children suspicious of multiple injuries or polytrauma received significantly fewer primary whole-body CTs in lowest level compared to intermediate level hospitals (36,07% vs. 56,57%; p = 0.015) and lowest level compared to highest level hospitals (36,07% vs. 68,42%; p = 0.001). Comparing the use of whole-body CT in intermediate to highest level hospitals a not significant increase in its use could be seen in highest level hospitals (56,57% vs. 68,42%; p = 0.174). According to our survey, taking care of polytraumatised children in Germany is not limited to specialised hospitals or a defined hospital level-of-care. Additionally, there is no established radiologic standard in work-up of the polytraumatised child. However, in higher hospital care -levels a higher percentage of hospitals employs whole-body CTs for primary

  16. Evaluation of Real-Time Quantitative PCR as a Standard Cytogenetic Diagnostic Tool for Confirmation of Microarray (aCGH) Results and Determination of Inheritance

    OpenAIRE

    Wang, Rubin; Carter, Jenny; Lench, Nicholas

    2013-01-01

    Aim: To evaluate the use of real-time quantitative PCR (qPCR) as a diagnostic tool for follow up of abnormal microarray (aCGH) results. Method: qPCR was performed on 207 samples with known aCGH results to detect chromosomal abnormality and determine the capability of qPCR. Eighty-four samples were processed and the results compared with the original aCGH result and with one or more of the alternative follow-up methods: aCGH, fluorescence in situ hybridization (FISH), or karyotyping. A separat...

  17. Fiscal 1997 report on the results of the international standardization R and D. Development of a test method of halogen-free flame-retardant cables and a study of the cable standards; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Non halogen nannen cable no shiken hoho kaihatsu narabini cable kikaku no kento

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    As for halogen-free flame-retardant cables with high recyclability and safety (HFFR cables), the development is being promoted in many countries as a next generation cable. The standard of HFFR cables has been set up by some countries and groups in the U.S. and Europe, but the international standard has not yet been established independently. The purpose of this R and D is the development of a test method to appropriately evaluate the performance of HFFR cables and its standardization, and the proposal of the international standardization on common items of the cable standard. A study group was sent to the U.S. and Europe to investigate the development, application status and test methods of the HFFR cable overseas. The ion chromatography and FT-IR method were studied as methods to evaluate corrosivity/toxicity of the gases emitted in combustion. The performance of HFFR cables in Japan and abroad was also evaluated mainly by IEC standards. Further, considering the results of the overseas surveys, the structure and details of the international standard plan on HFFR cables were studied, and approaches to the international standardization were studied. 32 refs., 31 figs., 54 tabs.

  18. Calculation of the Intensity of Physical Time Fluctuations Using the Standard Solar Model and its Comparison with the Results of Experimental Measurements

    Science.gov (United States)

    Morozov, A. N.

    2017-11-01

    The article reviews the possibility of describing physical time as a random Poisson process. An equation allowing the intensity of physical time fluctuations to be calculated depending on the entropy production density within irreversible natural processes has been proposed. Based on the standard solar model the work calculates the entropy production density inside the Sun and the dependence of the intensity of physical time fluctuations on the distance to the centre of the Sun. A free model parameter has been established, and the method of its evaluation has been suggested. The calculations of the entropy production density inside the Sun showed that it differs by 2-3 orders of magnitude in different parts of the Sun. The intensity of physical time fluctuations on the Earth's surface depending on the entropy production density during the sunlight-to-Earth's thermal radiation conversion has been theoretically predicted. A method of evaluation of the Kullback's measure of voltage fluctuations in small amounts of electrolyte has been proposed. Using a simple model of the Earth's surface heat transfer to the upper atmosphere, the effective Earth's thermal radiation temperature has been determined. A comparison between the theoretical values of the Kullback's measure derived from the fluctuating physical time model and the experimentally measured values of this measure for two independent electrolytic cells showed a good qualitative and quantitative concurrence of predictions of both theoretical model and experimental data.

  19. Comparison of the results obtained in the design of shallow foundations when applying the eurocode 7 and the Spanish standards; Comparacion del dimensionamiento de cimentaciones superficiales aplicando el Eurocodigo 7 y las normativas espanolas

    Energy Technology Data Exchange (ETDEWEB)

    Prieto Rodriguez, A.; Varela Nieto, J. M.; Magdaleno Mas, F.; Diaz Balteiro, L.; Saiz de Omenaca Gonzalez, J. A.; Saiz de Omena Gonzalez, J.; Lazaro Benito, F.; Macias Palomo, A.

    2008-07-01

    It has been done the comparison of the results obtained in the design of shallow foundations when the Eurocode 7 and different geotechnical Spanish Standards are applied (R.O.M. 05-94). Guia de cimentaciones para Obras de Carretera y Documento Basico SE-C del Codigo Tecnico de la Edificacion). Several designs have been done with different types of soils, characterized by their strength parameters, and with different shapes of foundations. the comparison of the results makes it possible to quantify the differences that exist between the European and the Spanish Standards. (Author) 8 refs.

  20. Reference Data for Standardized Quality of Life Questionnaires in Indian Patients with Brain Metastases from Non-small Cell Lung Cancer: Results from a Prospective Study.

    Science.gov (United States)

    Aggarwal, Jaiprakash; Chakraborty, Santam; Ghosh Laskar, Sarbani; Patil, Vijay M; Prabhash, Kumar; Bhattacharya, Atanu; Noronha, Vanita; Purandare, Nilendu C; Joshi, Amit; Mummudi, Naveen; Arora, Jitendra; Badhe, Rupali

    2017-04-10

    Reference data for European Organization for Research and Treatment of Cancer (EORTC) quality of life questionnaires do not include studies from the Indian subcontinent. The objective of the current study was to establish a reference dataset for Indian patients of non-small cell lung cancer (NSCLC) presenting with brain metastases (BM). One hundred forty patients with NSCLC with BM treated between 2012-2015 were registered in a prospective cohort study (CTRI/2013/01/003299). The baseline quality of life was evaluated using the EORTC general quality of life questionnaire QLQ-C30 and lung cancer specific module LC13. Minimum important difference (MID) scores for individual domains of the EORTC QLQ-C30 and LC13 questionnaires were derived (MID = 0.2 x standard deviation) from the reference data for patients with recurrent/metastatic lung cancers. In addition, a systematic review was conducted to identify studies reporting baseline quality of life scores for recurrent/metastatic NSCLC. Scores of several functional as well as symptom scales in the current NSCLC population differed by more than the MID from the baseline mean scores in the reference EORTC population as well as that reported from other studies. Differences in mean score from the EORTC reference data ranged from 6.2 and 9.4 points for the role functioning and cognitive functioning domains. In the symptom scales, the largest differences were observed for the financial difficulties (23.9) scores for the QLQ-C30 and peripheral neuropathy (21.7) for LC13 questionnaires. The current study demonstrates that baseline reference scores need to be established for patients from the Indian subcontinent. The findings from the current study have important implications for studies employing quality of life (QOL) assessment in the Indian NSCLC patient population.

  1. Standard growth of the foot arch in childhood and adolescence--derived from the measurement results of 10,155 children.

    Science.gov (United States)

    Waseda, Akeo; Suda, Yasunori; Inokuchi, Suguru; Nishiwaki, Yuji; Toyama, Yoshiaki

    2014-09-01

    The definition of flatfoot remains analytically vague. Toward the purpose of establishing the standard values of the foot length and arch height in childhood and adolescence, large-scale measurement and investigation of the foot arch were conducted using a three-dimensional foot-measuring device. Measurements of foot structure were performed on 5311 boys and 4844 girls, for a total of 20,310 ft. of 10,155 children aged from 6 to 18 years during the 2006-2008 year period. The foot length (FL) and the navicular height (NH) were measured, and the arch height ratio (AHR (%)=NH×100/FL) was calculated. The FL in boys showed an extension from the age of 6 to 14 and nearly reached a plateau at 14 years old. In girls, the extension was observed from the age of 6 to 13, and the FL came to a plateau at 13 years old. The NH in boys increased from the age of 6 to 13. In girls, the NH increased from the age of 8 to 13. The AHR, presented a normal distribution, and no differences were observed in the distribution for all ages in boys and girls. In boys, the AHR was almost flat until 11 years old, but elevated in the 11-13 year age period. In girls, the AHR was almost flat until 10 years old, but elevated in the 10-12 year age period. We are certain that the data demonstrating the normal growth of the foot contribute to the diagnosis and treatment of the failure of the foot to thrive. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  2. Collaboration Between Multistakeholder Standards

    DEFF Research Database (Denmark)

    Rasche, Andreas; Maclean, Camilla

    Public interest in corporate social responsibility (CSR) has resulted in a wide variety of multistakeholder CSR standards in which companies can choose to participate. While such standards reflect collaborative governance arrangements between public and private actors, the market for corporate...... responsibility is unlikely to support a great variety of partly competing and overlapping standards. Increased collaboration between these standards would enhance both their impact and their adoption by firms. This report examines the nature, benefits, and shortcomings of existing multistakeholder standards...

  3. Validity of standard reference values irrespective of rest and time of day prior to blood sampling-results from albumin and thyrotropin

    DEFF Research Database (Denmark)

    Andersen, I. B.; Brasen, C. L.; Christensen, H.

    2015-01-01

    electronically using Q-MATIC Suite. Impact of resting time and time of day on thyreotropin and albumin values was analyzed using a simple linear regression. The "maximum allowable bias" was used as quality indicator for the reference interval. Results: Using linear regression we found significant diurnal...

  4. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  5. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes.

    Science.gov (United States)

    Cadamuro, Janne; Mrazek, Cornelia; Leichtle, Alexander B; Kipman, Ulrike; Felder, Thomas K; Wiedemann, Helmut; Oberkofler, Hannes; Fiedler, Georg M; Haschke-Becher, Elisabeth

    2018-02-15

    Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed.

  6. Catalytic Functions of Standards

    NARCIS (Netherlands)

    K. Blind (Knut)

    2009-01-01

    textabstractThe three different areas and the examples have illustrated several catalytic functions of standards for innovation. First, the standardisation process reduces the time to market of inventions, research results and innovative technologies. Second, standards themselves promote the

  7. Non-small cell lung cancer in stages I-IIIB. Long-term results of definitive radiotherapy with doses {>=} 80 Gy in standard fractionation

    Energy Technology Data Exchange (ETDEWEB)

    Wurstbauer, Karl; Weise, Hannes; Deutschmann, Heinz; Kopp, Peter; Merz, Florian; Sedlmayer, Felix [Univ. Clinic of Radiotherapy and Radiation Oncology and radART - Inst. for research and development on Advanced Radiation Technologies, Paracelsus Medical Univ., Salzburg (Austria); Studnicka, Michael [Univ. Clinic of Pneumology, Paracelsus Medical Univ., Salzburg (Austria); Nairz, Olaf [Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany)

    2010-10-15

    Purpose: To investigate therapeutic outcome of dose escalation {>=} 80 Gy in nonresected non-small cell lung cancer (NSCLC). Patients and Methods: 124 consecutive patients with histologically/cytologically proven NSCLC were enrolled. Tumor stage I, II, IIIA, and IIIB was diagnosed in 30, eight, 39, and 47 patients, respectively. 38 patients (31%) had weight loss > 5% during the 3 months before diagnosis. A median dose of 88.2 Gy (range 80.0-96.0 Gy), 69.3 Gy (63.0-88.0 Gy) and 56.7 Gy was applied to primary lesions, involved lymph nodes, and elective nodes (within a region of about 6 cm cranial to macroscopically involved nodes), respectively. Daily fractional ICRU doses of 2.0-2.2 Gy were delivered by the conformal target-splitting technique. 58 patients (47%) received induction chemotherapy, in median two cycles prior to radiotherapy. Results: Median follow-up time of all patients was 19 months, of patients alive 72.4 months (69-121 months). The cumulative actual overall survival rate at 2 and 5 years amounts to 39% and 11.3%, respectively, resulting in a median overall survival time of 19.6 months. According to stages I, II, IIIA, and IIIB, the median overall survival times are 31.8, 31.4, 19.0, and 14.5 months, respectively. The locoregional tumor control rate at 2 years is 49%. Apart from one treatment-related death (pneumonitis), acute toxicity according to EORTC/RTOG scores was moderate: lung grade 2 (n = 7), grade 3 (n = 3); esophagus grade 1 (n = 11); heart grade 3 (n = 1, pericarditis). No late toxicity grade > 1 has been observed. Conclusion: Sequential, conventionally fractionated high-dose radiotherapy by conformal target splitting is well tolerated. The results for survival and locoregional tumor control seem to at least equalize the outcome of simultaneous chemoradiation approaches, which, at present, are considered ''state of the art'' for patients with nonresected NSCLC. A higher potential of radiation therapy might be reached

  8. Selection of single blastocysts for fresh transfer via standard morphology assessment alone and with array CGH for good prognosis IVF patients: results from a randomized pilot study

    Directory of Open Access Journals (Sweden)

    Yang Zhihong

    2012-05-01

    Full Text Available Abstract Background Single embryo transfer (SET remains underutilized as a strategy to reduce multiple gestation risk in IVF, and its overall lower pregnancy rate underscores the need for improved techniques to select one embryo for fresh transfer. This study explored use of comprehensive chromosomal screening by array CGH (aCGH to provide this advantage and improve pregnancy rate from SET. Methods First-time IVF patients with a good prognosis (age Results For patients in Group A (n = 55, 425 blastocysts were biopsied and analyzed via aCGH (7.7 blastocysts/patient. Aneuploidy was detected in 191/425 (44.9% of blastocysts in this group. For patients in Group B (n = 48, 389 blastocysts were microscopically examined (8.1 blastocysts/patient. Clinical pregnancy rate was significantly higher in the morphology + aCGH group compared to the morphology-only group (70.9 and 45.8%, respectively; p = 0.017; ongoing pregnancy rate for Groups A and B were 69.1 vs. 41.7%, respectively (p = 0.009. There were no twin pregnancies. Conclusion Although aCGH followed by frozen embryo transfer has been used to screen at risk embryos (e.g., known parental chromosomal translocation or history of recurrent pregnancy loss, this is the first description of aCGH fully integrated with a clinical IVF program to select single blastocysts for fresh SET in good prognosis patients. The observed aneuploidy rate (44.9% among biopsied blastocysts highlights the inherent imprecision of SET when conventional morphology is used alone. Embryos randomized to the aCGH group implanted with greater efficiency, resulted in clinical pregnancy more often, and yielded a lower miscarriage rate than those selected without aCGH. Additional studies are needed to verify our pilot data and confirm a role for on-site, rapid aCGH for IVF patients contemplating fresh SET.

  9. Accounting standards

    NARCIS (Netherlands)

    Stellinga, B.; Mügge, D.

    2014-01-01

    The European and global regulation of accounting standards have witnessed remarkable changes over the past twenty years. In the early 1990s, EU accounting practices were fragmented along national lines and US accounting standards were the de facto global standards. Since 2005, all EU listed

  10. FILTER-INDUCED BIAS IN Lyα EMITTER SURVEYS: A COMPARISON BETWEEN STANDARD AND TUNABLE FILTERS. GRAN TELESCOPIO CANARIAS PRELIMINARY RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    De Diego, J. A.; De Leo, M. A. [Instituto de Astronomía, Universidad Nacional Autónoma de México Avenida Universidad 3000, Ciudad Universitaria, C.P. 04510, Distrito Federal (Mexico); Cepa, J.; Bongiovanni, A. [Instituto de Astrofísica de Canarias, E-38205 La Laguna, Tenerife (Spain); Verdugo, T. [Centro de Investigaciones de Astronomía (CIDA), Apartado Postal 264, Mérida 5101-A (Venezuela, Bolivarian Republic of); Sánchez-Portal, M. [Herschel Science Centre (HSC), European Space Agency Centre (ESAC)/INSA, Villanueva de la Cañada, Madrid (Spain); González-Serrano, J. I., E-mail: jdo@astro.unam.mx [Instituto de Física de Cantabria (CSIC-Universidad de Cantabria), E-39005 Santander (Spain)

    2013-10-01

    Lyα emitter (LAE) surveys have successfully used the excess in a narrowband filter compared to a nearby broadband image to find candidates. However, the odd spectral energy distribution (SED) of LAEs combined with the instrumental profile has important effects on the properties of the candidate samples extracted from these surveys. We investigate the effect of the bandpass width and the transmission profile of the narrowband filters used for extracting LAE candidates at redshifts z ≅ 6.5 through Monte Carlo simulations, and we present pilot observations to test the performance of tunable filters to find LAEs and other emission-line candidates. We compare the samples obtained using a narrow ideal rectangular filter, the Subaru NB921 narrowband filter, and sweeping across a wavelength range using the ultra-narrow-band tunable filters of the instrument OSIRIS, installed at the 10.4 m Gran Telescopio Canarias. We use this instrument for extracting LAE candidates from a small set of real observations. Broadband data from the Subaru, Hubble Space Telescope, and Spitzer databases were used for fitting SEDs to calculate photometric redshifts and to identify interlopers. Narrowband surveys are very efficient in finding LAEs in large sky areas, but the samples obtained are not evenly distributed in redshift along the filter bandpass, and the number of LAEs with equivalent widths <60 Å can be underestimated. These biased results do not appear in samples obtained using ultra-narrow-band tunable filters. However, the field size of tunable filters is restricted because of the variation of the effective wavelength across the image. Thus, narrowband and ultra-narrow-band surveys are complementary strategies to investigate high-redshift LAEs.

  11. A phase III randomized trial comparing adjuvant concomitant chemoradiotherapy versus standard adjuvant chemotherapy followed by radiotherapy in operable node-positive breast cancer: Final results

    International Nuclear Information System (INIS)

    Rouesse, Jacques; Lande, Brigitte de la; Bertheault-Cvitkovic, Frederique; Serin, Daniel; Graic, Yvon; Combe, Martin; Leduc, Bernard; Lucas, Virginie; Demange, Liliane; Tan Dat Nguyen; Castera, Daniel; Krzisch, Claude; Villet, Richard; Mouret-Fourme, Emmanuelle; Garbay, Jean-Remy; Nogues, Catherine

    2006-01-01

    Purpose: To compare concomitant and sequential adjuvant chemoradiotherapy regimens in node-positive, operable breast cancer patients. Methods and Materials: This was a randomized, French, multicenter, phase III trial enrolling 638 eligible women with prior breast surgery and positive axillary dissection. Patients in Arm A received 500 mg/m 2 5-fluorouracil, 12 mg/m 2 mitoxantrone, and 500 mg/m 2 cyclophosphamide, with concomitant radiotherapy (50 Gy ± 10-20-Gy boost). Patients in Arm B received 500 mg/m 2 5-fluorouracil, 60 mg/m 2 epirubicin, and 500 mg/m 2 cyclophosphamide, with subsequent radiotherapy. Chemotherapy was administered on Day 1 every 21 days for 4 cycles. Results: Median treatment durations were 64 and 126 days (Arms A and B, respectively), with no significant difference in overall or disease-free survival. Five-year locoregional relapse-free survival favored patients with conservative surgery (two thirds of the population), with less local and/or regional recurrence in Arm A than in Arm B (3% vs. 9%; p 0.01). Multivariate analysis in this subgroup showed a 2.8-fold increased risk of locoregional recurrence with sequential chemoradiotherapy, independent of other prognostic factors (p = 0.027). Febrile neutropenia and Grade 3-4 leukopenia were significantly more frequent in Arm A. Subclinical left ventricular ejection fraction events at 1 year were more frequent with concomitant radiotherapy (p = 0.02). Conclusions: Concomitant radiotherapy with adjuvant fluorouracil, mitoxantrone, and cyclophosphamide has significantly better locoregional control in node-positive breast cancer after conservative surgery and 50% shorter treatment, albeit with slightly more acute toxicity. With mitoxantrone no longer available for adjuvant breast cancer treatment, alternative concomitant chemoradiotherapy studies are needed

  12. Prime mission results of the dual-frequency precipitation radar on the global precipitation measurement core spacecraft and the version 5 GPM standard products

    Science.gov (United States)

    Furukawa, K.; Nio, T.; Oki, R.; Kubota, T.; Iguchi, T.

    2017-09-01

    The Dual-frequency Precipitation Radar (DPR) on the Global Precipitation Measurement (GPM) core satellite was developed by Japan Aerospace Exploration Agency (JAXA) and National Institute of Information and Communications Technology (NICT). The objective of the GPM mission is to observe global precipitation more frequently and accurately. The GPM core satellite is a joint product of National Aeronautics and Space Administration (NASA), JAXA and NICT. NASA developed the satellite bus and the GPM Microwave Imager (GMI), and JAXA and NICT developed the DPR. The inclination of the GPM core satellite is 65 degrees, and the nominal flight altitude is 407 km. The non-sunsynchronous circular orbit is necessary for measuring the diurnal change of rainfall. The DPR consists of two radars, which are Ku-band precipitation radar (KuPR) and Ka-band precipitation radar (KaPR). GPM core observatory was successfully launched by H2A launch vehicle on Feb. 28, 2014. DPR orbital check out was completed in May 2014. DPR products were released to the public on Sep. 2, 2014 and Normal Observation Operation period was started. JAXA is continuing DPR trend monitoring, calibration and validation operations to confirm that DPR keeps its function and performance on orbit. The results of DPR trend monitoring, calibration and validation show that DPR kept its function and performance on orbit during the 3 years and 2 months prime mission period. The DPR Prime mission period was completed in May 2017. The version 5 GPM products were released to the public in 2017. JAXA confirmed that GPM/DPR total system performance and the GPM version 5 products achieved the success criteria and the performance indicators that were defined for the JAXA GPM/DPR mission.

  13. Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

    Energy Technology Data Exchange (ETDEWEB)

    Veltri, Andrea, E-mail: andrea.veltri@unito.it; Busso, Marco; Sardo, Diego; Angelino, Valeria; Priola, Adriano M. [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Novello, Silvia [University of Torino, Department of Oncology, San Luigi Gonzaga Hospital (Italy); Barba, Matteo [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Gatti, Gaia; Righi, Luisella [University of Torino, Department of Pathology, San Luigi Gonzaga Hospital (Italy)

    2017-06-15

    PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

  14. Randomized, Multicenter Trial on the Effect of Radiation Therapy on Plantar Fasciitis (Painful Heel Spur) Comparing a Standard Dose With a Very Low Dose: Mature Results After 12 Months' Follow-Up

    Energy Technology Data Exchange (ETDEWEB)

    Niewald, Marcus, E-mail: marcus.niewald@uks.eu [Department of Radiation Oncology, Saarland University Medical Center, Homburg/Saar (Germany); Seegenschmiedt, M. Heinrich [Radiotherapy Center, Hamburg (Germany); Micke, Oliver [Franziskus Hospital, Bielefeld (Germany); Graeber, Stefan [Institute for Medical Biometry, Epidemiology and Medical Informatics, Saarland University Medical Center, Homburg/Saar (Germany); Muecke, Ralf [Lippe Hospital, Lemgo (Germany); Schaefer, Vera; Scheid, Christine; Fleckenstein, Jochen; Licht, Norbert; Ruebe, Christian [Department of Radiation Oncology, Saarland University Medical Center, Homburg/Saar (Germany)

    2012-11-15

    Purpose: To conduct a randomized trial of radiation therapy for painful heel spur, comparing a standard dose with a very low dose. Methods and Materials: Sixty-six patients were randomized to receive radiation therapy either with a total dose of 6.0 Gy applied in 6 fractions of 1.0 Gy twice weekly (standard dose) or with a total dose of 0.6 Gy applied in 6 fractions of 0.1 Gy twice weekly (low dose). In all patients lateral opposing 4- to 6-MV photon beams were used. The results were measured using a visual analogue scale, the Calcaneodynia score, and the SF12 health survey. The fundamental phase of the study ended after 3 months, and the follow-up was continued up to 1 year. Patients with insufficient pain relief after 3 months were offered reirradiation with the standard dosage at any time afterward. Results: Of 66 patients, 4 were excluded because of withdrawal of consent or screening failures. After 3 months the results in the standard arm were highly significantly superior compared with those in the low-dose arm (visual analogue scale, P=.001; Calcaneodynia score, P=.027; SF12, P=.045). The accrual of patients was stopped at this point. Further evaluation after 12 months' follow-up showed the following results: (1) highly significant fewer patients were reirradiated in the standard arm compared with the low-dose arm (P<.001); (2) the results of patients in the low-dose arm who were reirradiated were identical to those in the standard arm not reirradiated (reirradiation as a salvage therapy if the lower dose was ineffective); (3) patients experiencing a favorable result after 3 months showed this even after 12 months, and some results even improved further between 3 and 12 months. Conclusions: This study confirms the superior analgesic effect of radiation therapy with 6-Gy doses on painful heel spur even for a longer time period of at least 1 year.

  15. Spectroscopic investigation of the effect of salt on binding of tartrazine with two homologous serum albumins: quantification by use of the Debye-Hückel limiting law and observation of enthalpy-entropy compensation.

    Science.gov (United States)

    Bolel, Priyanka; Datta, Shubhashis; Mahapatra, Niharendu; Halder, Mintu

    2012-08-30

    Formation of ion pair between charged molecule and protein can lead to interesting biochemical phenomena. We report the evolution of thermodynamics of the binding of tartrazine, a negatively charged azo colorant, and serum albumins with salt. The dye binds predominantly electrostatically in low buffer strengths; however, on increasing salt concentration, affinity decreases considerably. The calculated thermodynamic parameters in high salt indicate manifestation of nonelectrostatic interactions, namely, van der Waals force and hydrogen bonding. Site-marker competitive binding studies and docking simulations indicate that the dye binds with HSA in the warfarin site and with BSA at the interface of warfarin and ibuprofen binding sites. The docked poses indicate nearby amino acid positive side chains, which are possibly responsible for electrostatic interaction. Using the Debye-Hückel interionic attraction theory for binding equilibria, it is shown that, for electrostatic binding the calculated free energy change increases linearly with square root of ionic strength. Also UV-vis, fluorescence, CD data indicate a decrease of interaction with salt concentration. This study quantitatively relates how ionic strength modulates the strength of the protein-ligand electrostatic interaction. The binding enthalpy and entropy have been found to compensate one another. The enthalpy-entropy compensation (EEC), general property of weak intermolecular interactions, has been discussed.

  16. Communications standards

    CERN Document Server

    Stokes, A V

    1986-01-01

    Communications Standards deals with the standardization of computer communication networks. This book examines the types of local area networks (LANs) that have been developed and looks at some of the relevant protocols in more detail. The work of Project 802 is briefly discussed, along with a protocol which has developed from one of the LAN standards and is now a de facto standard in one particular area, namely the Manufacturing Automation Protocol (MAP). Factors that affect the usage of networks, such as network management and security, are also considered. This book is divided into three se

  17. FY 1999 Report on the technical results. Research and development project for creation of the quick-effect type international standards (Standardization in the field of safety of machinery); 1999 nendo sokkogata kokusai hyojun sosei kenkyu kaihatsu jigyo seika hokokusho. Kikai anzensei ni kakawaru hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    It is necessary to standardize the concepts and terminology of safety, design principles, protection and technology for evaluation of safety over a wide range including designs and specifications, in order to secure safety of the users. The international standardization has been promoted, based on the European voluntary standards EN. It is necessary for Japan to propose the international standards reflecting the industrial environments of Japan, in order to keep and expand her international competitiveness. Those technologies developed for the above purposes include the safety-related ones based on the Japanese electronic technologies, electronized operation-controlling technologies with dynamic fail safe signal processing, DC power supply circuit with a failure-sensing circuit, opto-ultrasonic hybrid type personal sensing device and pressure-sensitive mat sensor, emergency stop devices having no electrical contact to eliminate the contact fusing risk, and video camera system which facilitates emergency stop action of machinery. These results are submitted to the related technical committees of ISO or IEC. A total of 46 items of the international standard proposal drafts related to IEC/TC44 are also submitted. (NEDO)

  18. Achieving Standardization

    DEFF Research Database (Denmark)

    Henningsson, Stefan

    2016-01-01

    competitive, national customs and regional economic organizations are seeking to establish a standardized solution for digital reporting of customs data. However, standardization has proven hard to achieve in the socio-technical e-Customs solution. In this chapter, the authors identify and describe what has......International e-Customs is going through a standardization process. Driven by the need to increase control in the trade process to address security challenges stemming from threats of terrorists, diseases, and counterfeit products, and to lower the administrative burdens on traders to stay...... to be harmonized in order for a global company to perceive e-Customs as standardized. In doing so, they contribute an explanation of the challenges associated with using a standardization mechanism for harmonizing socio-technical information systems....

  19. Achieving Standardization

    DEFF Research Database (Denmark)

    Henningsson, Stefan

    2014-01-01

    competitive, national customs and regional economic organizations are seeking to establish a standardized solution for digital reporting of customs data. However, standardization has proven hard to achieve in the socio-technical e-Customs solution. In this chapter, the authors identify and describe what has......International e-Customs is going through a standardization process. Driven by the need to increase control in the trade process to address security challenges stemming from threats of terrorists, diseases, and counterfeit products, and to lower the administrative burdens on traders to stay...... to be harmonized in order for a global company to perceive e-Customs as standardized. In doing so, they contribute an explanation of the challenges associated with using a standardization mechanism for harmonizing socio-technical information systems....

  20. Training Standardization

    International Nuclear Information System (INIS)

    Agnihotri, Newal

    2003-01-01

    The article describes the benefits of and required process and recommendations for implementing the standardization of training in the nuclear power industry in the United States and abroad. Current Information and Communication Technologies (ICT) enable training standardization in the nuclear power industry. The delivery of training through the Internet, Intranet and video over IP will facilitate this standardization and bring multiple benefits to the nuclear power industry worldwide. As the amount of available qualified and experienced professionals decreases because of retirements and fewer nuclear engineering institutions, standardized training will help increase the number of available professionals in the industry. Technology will make it possible to use the experience of retired professionals who may be interested in working part-time from a remote location. Well-planned standardized training will prevent a fragmented approach among utilities, and it will save the industry considerable resources in the long run. It will also ensure cost-effective and safe nuclear power plant operation

  1. Evaluation of the quality of results obtained in institutions participating in interlaboratory experiments and of the reliability characteristics of the analytical methods used on the basis of certification of standard soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Parshin, A.K.; Obol' yaninova, V.G.; Sul' dina, N.P.

    1986-08-20

    Rapid monitoring of the level of pollution of the environment and, especially, of soils necessitates preparation of standard samples (SS) close in properties and material composition to the objects to be analyzed. During 1978-1982 four sets (three types of samples in each) of State Standard Samples of different soils were developed: soddy-podzolic sandy-loamy, typical chernozem, krasnozem, and calcareous sierozem. The certification studies of the SS of the soils were carried out in accordance with the classical scheme of interlab experiment (ILE). More than 100 institutions were involved in the ILE and the total number of independent analytical results was of the order of 10/sup 4/. With such a volume of analytical information at their disposal they were able to find some general characteristics intrinsic to certification studies, to assess the quality of work of the ILE participants with due regard for their specialization, and the reliability characteristics of the analytical methods used.

  2. Fiscal 1997 report on the results of the international standardization R and D. Data format for rapid prototyping systems; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Sekiso zokei system yo data format

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    Concerning the rapid prototyping (RP) system use new RP format and the related software, the paper promoted the international standardization in consideration of relationships with an international standard, STEP. RP, which is a technology to rapidly prototype a solid body based on the three-dimensional CAD data, is used in various fields of product manufacture, medical field, etc., and is expected to further expand its field of application. In this R and D, an international version of the RP software system developed for domestic use was developed, and at the same time a software was trially manufactured so that the data on STEP/AP203/CC5 and CC6 can be delivered to the system. Moreover, a plan on new AIC51X as the STEP/AIC suitable for PR was studied. Relating to these results, the paper conducted the publicity work to the persons concerned in RP in the U.S. and Europe, and also explained those at ISO/TC184/SC4 (STEP Conference). The PR use interface enabling highly rapid and accurate data processing reached to a stage of the international commercialization, and at the same time the study items were materialized for proposal of the new STEP standards suitable for RP. 18 refs., 80 figs., 12 tabs.

  3. Search for the Standard Model Higgs boson through the decay of H→ZZ*→4l with the ATLAS experiment at LHC resulting to the observation of a new particle consistent with the Higgs boson

    International Nuclear Information System (INIS)

    Mountricha, E.

    2012-01-01

    The subject of this thesis is the search for the Standard Model Higgs boson through its decay into four leptons with the ATLAS experiment at CERN. The theory postulating the Higgs boson is presented and the constraints of the theory and direct and indirect searches are quoted. The ATLAS experiment and its components are described and the Detector Control System for the operation and monitoring of the power supplies of the Monitored Drift Tubes is detailed. The electron and muon reconstruction and identification are summarized. Studies on the muon fake rates, on the effect of pileup on the isolation of the muons, and on muon efficiencies of the isolation and impact parameter requirements are presented. The analysis of the Higgs decay to four leptons is detailed with emphasis on the background estimation, the methods employed and the control regions used. The results of the search using the 2011 νs= 7 TeV data are presented which have led to hints for the observation of the Higgs boson. The optimization performed for the search of a low mass Higgs boson is described and the effect on the 2011 data are shown. The analysis is performed for the 2011 νs = 8 TeV data collected up to July and the results are presented, including the combination with the 2011 data. These latest results have led to the observation of a new particle consistent with the Standard Model Higgs. (author) [fr

  4. Results of the CCRI(II)-S12.H-3 supplementary comparison: Comparison of methods for the calculation of the activity and standard uncertainty of a tritiated-water source measured using the LSC-TDCR method.

    Science.gov (United States)

    Cassette, Philippe; Altzitzoglou, Timotheos; Antohe, Andrei; Rossi, Mario; Arinc, Arzu; Capogni, Marco; Galea, Raphael; Gudelis, Arunas; Kossert, Karsten; Lee, K B; Liang, Juncheng; Nedjadi, Youcef; Oropesa Verdecia, Pilar; Shilnikova, Tanya; van Wyngaardt, Winifred; Ziemek, Tomasz; Zimmerman, Brian

    2018-04-01

    A comparison of calculations of the activity of a 3 H 2 O liquid scintillation source using the same experimental data set collected at the LNE-LNHB with a triple-to-double coincidence ratio (TDCR) counter was completed. A total of 17 laboratories calculated the activity and standard uncertainty of the LS source using the files with experimental data provided by the LNE-LNHB. The results as well as relevant information on the computation techniques are presented and analysed in this paper. All results are compatible, even if there is a significant dispersion between the reported uncertainties. An output of this comparison is the estimation of the dispersion of TDCR measurement results when measurement conditions are well defined. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The influence of like-charge attraction on the structure and dynamics of ionic liquids: NMR chemical shifts, quadrupole coupling constants, rotational correlation times and failure of Stokes-Einstein-Debye.

    Science.gov (United States)

    Strate, Anne; Overbeck, Viviane; Lehde, Viktoria; Neumann, Jan; Bonsa, Anne-Marie; Niemann, Thomas; Paschek, Dietmar; Michalik, Dirk; Ludwig, Ralf

    2018-02-21

    Ion pairing is one of the most fundamental atomic interactions in chemistry and biology. In contrast, pairing between like-charged ions remains an elusive concept. So far, this phenomenon was observed only for large-scaled structures, assemblies, stabilizing frameworks, or in aqueous solution wherein like-charge attraction is supported by mediating water molecules. Recently, we reported the formation of cationic clusters in pure ionic liquids (ILs) which all include hydroxyl groups (OH) for possible hydrogen bonding. In such structures like-charge repulsion is overcome by cooperative hydrogen bonds. The vibrational bands in the OH-stretch region of the infrared spectra can be clearly assigned to H-bonded ion pairs (c-a) or to H-bonded cationic clusters (c-c). The equilibrium between both types of ionic clusters can be controlled by using the same cation but differently strong interacting anions. In the present work, we study the influence of the cationic cluster formation on structural and dynamical NMR properties of ionic liquids, where we know that they form cationic clusters to different extent. First, we measure proton chemical shifts, δ 1 H, and determine deuteron quadrupole coupling constants, χ D , from a calculated relation between both NMR properties. Reliable χ D values for the liquid phase are a prerequisite for calculating reorientational correlation times, τ OH , from measured deuteron relaxation times, T 1 . It is shown that the correlation times are significantly influenced by the amount of cationic clusters present in the IL. The Stokes-Einstein-Debye (SED) relation is valid for the ILs wherein H-bonded ion pairs (c-a) are the dominant species. With increasing cationic cluster (c-c) formation of e.g. cyclic tetramers, SED breaks down because of the structural heterogeneities.

  6. Frequency standards

    CERN Document Server

    Riehle, Fritz

    2006-01-01

    Of all measurement units, frequency is the one that may be determined with the highest degree of accuracy. It equally allows precise measurements of other physical and technical quantities, whenever they can be measured in terms of frequency.This volume covers the central methods and techniques relevant for frequency standards developed in physics, electronics, quantum electronics, and statistics. After a review of the basic principles, the book looks at the realisation of commonly used components. It then continues with the description and characterisation of important frequency standards

  7. Results of a prospective clinical study on the diagnostic performance of standard magnetic resonance imaging in comparison to a combination of 3T MRI and additional CT imaging in Kienböck's disease.

    Science.gov (United States)

    Stahl, Stephane; Hentschel, Pascal; Ketelsen, Dominik; Grosse, Ulrich; Held, Manuel; Wahler, Theodora; Syha, Roland; Schaller, Hans-Eberhard; Nikolaou, Konstantin; Grözinger, Gerd

    2017-05-01

    This prospective clinical study examined standard wrist magnetic resonance imaging (MRI) examinations and the incremental value of computed tomography (CT) in the diagnosis of Kienböck's disease (KD) with regard to reliability and precision in the different diagnostic steps during diagnostic work-up. Sixty-four consecutive patients referred between January 2009 and January 2014 with positive initial suspicion of KD according to external standard wrist MRI were prospectively included (step one). Institutional review board approval was obtained. Clinical examination by two handsurgeons were followed by wrist radiographs (step two), ultrathin-section CT, and 3T contrast-enhanced MRI (step three). Final diagnosis was established in a consensus conference involving all examiners and all examinations results available from step three. In 12/64 patients, initial suspicion was discarded at step two and in 34/64 patients, the initial suspicion of KD was finally discarded at step three. The final external MRI positive predictive value was 47%. The most common differential diagnoses at step three were intraosseous cysts (n=15), lunate pseudarthrosis (n=13), and ulnar impaction syndrome (n=5). A correlation between radiograph-based diagnoses (step two) with final diagnosis (step three) showed that initial suspicion of stage I KD had the lowest sensitivity for correct diagnosis (2/11). Technical factors associated with a false positive external MRI KD diagnosis were not found. Standard wrist MRI should be complemented with thin-section CT, and interdisciplinary interpretation of images and clinical data, to increase diagnostic accuracy in patients with suspected KD. Copyright © 2017. Published by Elsevier B.V.

  8. The early toxicity of escalated versus standard dose conformal radiotherapy with neo-adjuvant androgen suppression for patients with localised prostate cancer: Results from the MRC RT01 trial (ISRCTN47772397)

    International Nuclear Information System (INIS)

    Dearnaley, David P.; Sydes, Matthew R.; Langley, Ruth E.; Graham, John D.; Huddart, Robert A.; Syndikus, Isabel; Matthews, John H.L.; Scrase, Christopher D.; Jose, Chakiath C.; Logue, John; Stephens, Richard J.

    2007-01-01

    Background: Five-year disease-free survival rates for localised prostate cancer following standard doses of conventional radical external beam radiotherapy are around 80%. Conformal radiotherapy (CFRT) raises the possibility that radiotherapy doses can be increased and long-term efficacy outcomes improved, with safety an important consideration. Methods: MRC RT01 is a randomised controlled trial of 862 men with localised prostate cancer comparing Standard CFRT (64 Gy/32 f) versus Escalated CFRT (74 Gy/37 f), both administered with neo-adjuvant androgen suppression. Early toxicity was measured using physician-reported instruments (RTOG, LENT/SOM, Royal Marsden Scales) and patient-reported questionnaires (MOS SF-36, UCLA Prostate Cancer Index, FACT-P). Results: Overall early radiotherapy toxicity was similar, apart from increased bladder, bowel and sexual toxicity, in the Escalated Group during a short immediate post-radiotherapy period. Toxicity in both groups had abated by week 12. Using RTOG Acute Toxicity scores, cumulative Grade ≥2 bladder and bowel toxicity was 38% and 30% for Standard Group and 39% and 33% in Escalated Group, respectively. Urinary frequency (Royal Marsden Scale) improved in both groups from pre-androgen suppression to 6 months post-radiotherapy (p < 0.001), but bowel and sexual functioning deteriorated. This pattern was supported by patient-completed assessments. Six months after starting radiotherapy the incidence of RTOG Grade ≥2 side-effects was low (<1%); but there were six reports of rectal ulceration (6 Escalated Group), six haematuria (5 Escalated Group) and eight urethral stricture (6 Escalated Group). Conclusions: The two CFRT schedules with neo-adjuvant androgen suppression have broadly similar early toxicity profiles except for the immediate post-RT period. At 6 months and compared to before hormone therapy, bladder symptoms improved, whereas bowel and sexual symptoms worsened. These assessments of early treatment safety will be

  9. Relevant Standards

    Indian Academy of Sciences (India)

    .86: Ethernet over LAPS. Standard in China and India. G.7041: Generic Framing Procedure (GFP). Supports Ethernet as well as other data formats (e.g., Fibre Channel); Protocol of ... IEEE 802.3x for flow control of incoming Ethernet data ...

  10. Requirements of quality standards

    International Nuclear Information System (INIS)

    Mueller, J.

    1977-01-01

    The lecture traces the development of nuclear standards, codes, and Federal regulations on quality assurance (QA) for nuclear power plants and associated facilities. The technical evolution of the last twelve years, especially in the area of nuclear technology, led to different activities and regulatory initiatives, and the present result is: several nations have their own homemade standards. The lecture discusses the former and especially current activities in standard development, and gives a description of the requirements of QA-standards used in USA and Europe, especially Western Germany. Furthermore the lecture attempts to give a comparison and an evaluation of the international quality standards from the author's viewpoint. Finally the lecture presents an outlook for the future international implications of QA-standards. There is an urgent need within the nuclear industry for simplification and standardization of QA-standards. The relationship between the various standards, and the applicability of the standards need clarification and a better transparancy. To point out these problems is the purpose of the lecture. (orig.) [de

  11. Reduced-Intensity Delayed Intensification in Standard-Risk Pediatric Acute Lymphoblastic Leukemia Defined by Undetectable Minimal Residual Disease: Results of an International Randomized Trial (AIEOP-BFM ALL 2000).

    Science.gov (United States)

    Schrappe, Martin; Bleckmann, Kirsten; Zimmermann, Martin; Biondi, Andrea; Möricke, Anja; Locatelli, Franco; Cario, Gunnar; Rizzari, Carmelo; Attarbaschi, Andishe; Valsecchi, Maria Grazia; Bartram, Claus R; Barisone, Elena; Niggli, Felix; Niemeyer, Charlotte; Testi, Anna Maria; Mann, Georg; Ziino, Ottavio; Schäfer, Beat; Panzer-Grümayer, Renate; Beier, Rita; Parasole, Rosanna; Göhring, Gudrun; Ludwig, Wolf-Dieter; Casale, Fiorina; Schlegel, Paul-Gerhardt; Basso, Giuseppe; Conter, Valentino

    2018-01-20

    Purpose Delayed intensification (DI) is an integral part of treatment of childhood acute lymphoblastic leukemia (ALL), but it is associated with relevant toxicity. Therefore, standard-risk patients of trial AIEOP-BFM ALL 2000 (Combination Chemotherapy Based on Risk of Relapse in Treating Young Patients With ALL) were investigated with the specific aim to reduce treatment intensity. Patients and Methods Between July 2000 and July 2006, 1,164 patients (1 to 17 years of age) with standard-risk ALL (defined as the absence of high-risk cytogenetics and undetectable minimal residual disease on days 33 and 78) were randomly assigned to either experimental reduced-intensity DI (protocol III; P-III) or standard DI (protocol II; P-II). Cumulative drug doses of P-III were reduced by 30% for dexamethasone and 50% for vincristine, doxorubicin, and cyclophosphamide, which shortened the treatment duration from 49 to 29 days. The study aimed at noninferiority of reduced-intensity P-III; analyses were performed according to treatment given. Results For P-III and P-II, respectively, the 8-year rate of disease-free survival (± SE) was 89.2 ± 1.3% and 92.3 ± 1.2% ( P = .04); cumulative incidence of relapse, 8.7 ± 1.2% and 6.4 ± 1.1% ( P = .09); and overall survival, 96.1 ± 0.8% and 98.0 ± 0.6% ( P = .06). Patients with ETV6-RUNX1-positive ALL and patients 1 to 6 years of age performed equally well in both arms. The incidence of death during remission was comparable, which indicates equivalent toxicity. The 8-year cumulative incidence rate of secondary malignancies was 1.3 ± 0.5% and 0.6 ± 0.4% for P-III and P-II, respectively ( P = .37). Conclusion Although the criteria used for the standard-risk definition in this trial identified patients with exceptionally good prognosis, reduction of chemotherapy was not successful mainly because of an increased rate of relapse. The data suggest that treatment reduction is feasible in specific subgroups, which underlines the biologic

  12. A brief, standardized tool for measuring HIV-related stigma among health facility staff: results of field testing in China, Dominica, Egypt, Kenya, Puerto Rico and St. Christopher & Nevis

    Science.gov (United States)

    Nyblade, Laura; Jain, Aparna; Benkirane, Manal; Li, Li; Lohiniva, Anna-Leena; McLean, Roger; Turan, Janet M; Varas-Díaz, Nelson; Cintrón-Bou, Francheska; Guan, Jihui; Kwena, Zachary; Thomas, Wendell

    2013-01-01

    Introduction Within healthcare settings, HIV-related stigma is a recognized barrier to access of HIV prevention and treatment services and yet, few efforts have been made to scale-up stigma reduction programs in service delivery. This is in part due to the lack of a brief, simple, standardized tool for measuring stigma among all levels of health facility staff that works across diverse HIV prevalence, language and healthcare settings. In response, an international consortium led by the Health Policy Project, has developed and field tested a stigma measurement tool for use with health facility staff. Methods Experts participated in a content-development workshop to review an item pool of existing measures, identify gaps and prioritize questions. The resulting questionnaire was field tested in six diverse sites (China, Dominica, Egypt, Kenya, Puerto Rico and St. Christopher & Nevis). Respondents included clinical and non-clinical staff. Questionnaires were self- or interviewer-administered. Analysis of item performance across sites examined both psychometric properties and contextual issues. Results The key outcome of the process was a substantially reduced questionnaire. Eighteen core questions measure three programmatically actionable drivers of stigma within health facilities (worry about HIV transmission, attitudes towards people living with HIV (PLHIV), and health facility environment, including policies), and enacted stigma. The questionnaire also includes one short scale for attitudes towards PLHIV (5-item scale, α = 0.78). Conclusions Stigma-reduction programmes in healthcare facilities are urgently needed to improve the quality of care provided, uphold the human right to healthcare, increase access to health services, and maximize investments in HIV prevention and treatment. This brief, standardized tool will facilitate inclusion of stigma measurement in research studies and in routine facility data collection, allowing for the monitoring of stigma within

  13. Standardization: colorfull or dull?

    Science.gov (United States)

    van Nes, Floris L.

    2003-01-01

    After mentioning the necessity of standardization in general, this paper explains how human factors, or ergonomics standardization by ISO and the deployment of information technology were linked. Visual display standardization is the main topic; the present as well as the future situation in this field are treated, mainly from an ISO viewpoint. Some observations are made about the necessary and interesting co-operation between physicists and psychologists, of different nationality, who both may be employed by either private enterprise or governmental institutions, in determining visual display requirements. The display standard that is to succeed the present ISO standards in this area: ISO 9241-3, -7, -8 and ISO 13406-1, -2, will have a scope that is not restricted to office tasks. This means a large extension of the contexts for which display requirements have to be investigated and specified especially if mobile use of displays, under outdoor lighting conditions, is included. The new standard will be structured in such a way that it is better accessible than the present ones for different categories of standards users. The subject color in the new standard is elaborated here. A number of questions are asked as to which requirements on color rendering should be made, taking new research results into account, and how far the new standard should go in making recommendations to the display user.

  14. Learning curve for a modified Watson-Jones minimally invasive approach in primary total hip replacement: analysis of complications and early results versus the standard-incision posterior approach.

    Science.gov (United States)

    Laffosse, Jean-Michel; Chiron, Philippe; Accadbled, Franck; Molinier, François; Tricoire, Jean-Louis; Puget, Jean

    2006-12-01

    We analysed the learning curve of an anterolateral minimally invasive (ALMI) approach for primary total hip replacement (THR). The first 42 THR's with large-diameter heads implanted through this approach (group 1) were compared to a cohort of 58 THR's with a 28-mm head performed through a standard-incision posterior approach (group 2). No selection was made and the groups were comparable. Implant positioning as well as early clinical results were satisfactory and were comparable in the two groups. In group 1, the rate of intraoperative complications was significantly higher (greater trochanter fracture in 4 cases, cortical perforation in 3 cases, calcar fracture in one case, nerve palsy in one case, secondary tilting of the metal back in 2 cases) than in group 2 (one nerve palsy and one calcar crack). At 6 months, one revision of the acetabular cup was performed in group 1 for persistent pain, whereas in group 2, we noted 3 dislocations (2 were revised) and 2 periprosthetic femoral fractures. Our study showed a high rate of intra- and perioperative complications during the learning curve for an ALMI approach. These are more likely to occur in obese or osteoporotic patients, and in those with bulky muscles or very stiff hips. Postoperative complications were rare. The early clinical results are excellent and we may expect to achieve better results with a more standardised procedure. During the initial period of the learning curve, it would be preferable to select patients with an appropriate morphology.

  15. CALCULATION AND EXPERIMENTAL ESTIMATION OF RESULTS OF ELECTRO-THERMAL ACTION OF RATIONED BY THE INTERNATIONAL STANDARD IEC 62305-1-2010 IMPULSE CURRENT OF SHORT BLOW OF ARTIFICIAL LIGHTNING ON THE THIN-WALLED COVERAGE FROM STAINLESS STEEL

    Directory of Open Access Journals (Sweden)

    M. I. Baranov

    2017-03-01

    Full Text Available Purpose. Calculation and experimental researches of electro-thermal resistibility of the pre-production thin-walled sheet models of outward roof of height technical buildings from stainless steel are easily soiled 12Х18Н10Т to direct action on them rationed by the International Standard IEC 62305-1-2010 aperiodic impulse of current of short bow of artificial lightning of temporal form 10/350 μs with the proper admittances on his peak-temporal parameters (PTP. Methodology. Electrophysics bases of technique of high voltage and large impulsive currents (LIC, and also scientific and technical bases of planning of high-voltage impulsive devices and measuring methods in them LIC with followings below extreme PTP: amplitude of impulse of current of ImL=200 кА (with admittance ±10 %; integral of action of impulse of current of JL=10·106 A2·s (with admittance ±35 %; %; duration of wavefront current of T1=10 μs (with admittance ±20 %; time, proper amplitude of impulse of current of ImL, tmL≤24 μs (with admittance ±20 %; duration of flowing of impulse of current of T2=350 μs (with admittance ±10 %. Results. The results of evaluation calculation and experimental researches of electro-thermal resistibility of the indicated pre-production sheet models are resulted measuring in the plan of 0,5 x 0,5 m from stainless steel are easily soiled the 12Х18Н10Т thickness of 1 mm to action on them of aperiodic impulse of current of short blow of artificial lightning with rationed PTP on the requirements of the International Standard IEC 62305-1-2010. In high current experiments amplitude of ImL of the aperiodic rationed impulse of current of artificial lightning of temporal form of T1/T2=15 μs/315 μs changed in the range of (100-184 кА. The integral of action of JL of impulse of current for I-IV of levels of protection of lightning of technical objects (TO numeral made from 2,32·106 А2·s to 7,88·106 А2·s, and the flowing through the

  16. Analytical method for the identification and assay of 12 phthalates in cosmetic products: application of the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques".

    Science.gov (United States)

    Gimeno, Pascal; Maggio, Annie-Françoise; Bousquet, Claudine; Quoirez, Audrey; Civade, Corinne; Bonnet, Pierre-Antoine

    2012-08-31

    Esters of phthalic acid, more commonly named phthalates, may be present in cosmetic products as ingredients or contaminants. Their presence as contaminant can be due to the manufacturing process, to raw materials used or to the migration of phthalates from packaging when plastic (polyvinyl chloride--PVC) is used. 8 phthalates (DBP, DEHP, BBP, DMEP, DnPP, DiPP, DPP, and DiBP), classified H360 or H361, are forbidden in cosmetics according to the European regulation on cosmetics 1223/2009. A GC/MS method was developed for the assay of 12 phthalates in cosmetics, including the 8 phthalates regulated. Analyses are carried out on a GC/MS system with electron impact ionization mode (EI). The separation of phthalates is obtained on a cross-linked 5%-phenyl/95%-dimethylpolysiloxane capillary column 30 m × 0.25 mm (i.d.) × 0.25 mm film thickness using a temperature gradient. Phthalate quantification is performed by external calibration using an internal standard. Validation elements obtained on standard solutions, highlight a satisfactory system conformity (resolution>1.5), a common quantification limit at 0.25 ng injected, an acceptable linearity between 0.5 μg mL⁻¹ and 5.0 μg mL⁻¹ as well as a precision and an accuracy in agreement with in-house specifications. Cosmetic samples ready for analytical injection are analyzed after a dilution in ethanol whereas more complex cosmetic matrices, like milks and creams, are assayed after a liquid/liquid extraction using ter-butyl methyl ether (TBME). Depending on the type of cosmetics analyzed, the common limits of quantification for the 12 phthalates were set at 0.5 or 2.5 μg g⁻¹. All samples were assayed using the analytical approach described in the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". This analytical protocol is particularly adapted when it is not possible to make reconstituted sample matrices. Copyright © 2012

  17. Radiological Control Technician: Standardized technician Qualification Standard

    International Nuclear Information System (INIS)

    1992-10-01

    The Qualification Standard states and defines the knowledge and skill requirements necessary for successful completion of the Radiological Control Technician Training Program. The standard is divided into three phases: Phase I concerns RCT Academic training. There are 13 lessons associated with the core academics program and 19 lessons associated with the site academics program. The staff member should sign the appropriate blocks upon successful completion of the examination for that lesson or group of lessons. In addition, facility specific lesson plans may be added to meet the knowledge requirements in the Job Performance Measures (JPM) of the practical program. Phase II concerns RCT core/site practical (JPMs) training. There are thirteen generic tasks associated with the core practical program. Both the trainer/evaluator and student should sign the appropriate block upon successful completion of the JPM. In addition, facility specific tasks may be added or generic tasks deleted based on the results of the facility job evaluation. Phase III concerns the oral examination board successful completion of the oral examination board is documented by the signature of the chairperson of the board. Upon completion of all of the standardized technician qualification requirements, final qualification is verified by the student and the manager of the Radiological Control Department and acknowledged by signatures on the qualification standard. The completed Qualification Standard shall be maintained as an official training record

  18. Teachers Voices Interpreting Standards

    Directory of Open Access Journals (Sweden)

    Leo C. Rigsby

    2003-11-01

    Full Text Available The State of Virginia has adopted state-mandated testing that aims to raise the standards of performance for children in our schools in a manner that assigns accountability to schools and to teachers. In this paper we argue that the conditions under which the standards were created and the testing implemented undermine the professionalism of teachers. We believe this result has the further consequence of compromising the critical thinking and learning processes of children. We argue this has happened because teachers’ views and experiences have driven neither the setting of standards nor the assessment of their achievement. We use data from essays by teachers in an innovative masters program to compare teachers’ experiences involving the Virginia Standards of Learning with ideal standards for professional development adopted by the National Board for Professional Teaching Standards. We argue that there are serious negative consequences of the failure to include dialogue with K-12 teachers in setting standards and especially in the creation of assessments to measure performances relative to the standards. We believe the most successful, honest, and morally defensible processes must be built on the experience and wisdom of classroom teachers.

  19. Intensity-Modulated Radiotherapy Reduces Radiation-Induced Morbidity and Improves Health-Related Quality of Life: Results of a Nonrandomized Prospective Study Using a Standardized Follow-Up Program

    International Nuclear Information System (INIS)

    Vergeer, Marije R.; Doornaert, Patricia A.H.; Rietveld, Derek H.F.; Leemans, C. Rene; Slotman, Ben J.; Langendijk, Johannes A.

    2009-01-01

    Purpose: The purpose of this study was to compare intensity-modulated radiation therapy (IMRT) and three-dimensional conventional radiotherapy (3D-CRT) with regard to patient-rated xerostomia, Radiation Therapy Oncology Group (RTOG) acute and late xerostomia and health-related quality of life (HRQoL) among patients with head and neck squamous cell carcinoma (HNSCC). Methods and Materials: Included were 241 patients with HNSCC treated with bilateral irradiation ± chemotherapy. Since 2000, all patients treated with HNSCC were included in a program, which prospectively assessed acute and late morbidity according to the RTOG and HRQoL on a routine basis at regular intervals. Before October 2004, all patients were treated with 3D-CRT (N = 150). After clinical implementation in October 2004, 91 patients received IMRT. In this study, the differences regarding RTOG toxicity, xerostomia, and other items of HRQoL were analyzed. Results: The use of IMRT resulted in a significant reduction of the mean dose of the parotid glands (27 Gy vs. 43 Gy (p < 0.001). During radiation, Grade 2 RTOG xerostomia was significantly less with IMRT than with 3D-CRT. At 6 months, the prevalence of patient-rated moderate to severe xerostomia and Grade 2 or higher RTOG xerostomia was significantly lower after IMRT versus 3D-CRT. Treatment with IMRT also had a positive effect on several general and head and neck cancer-specific HRQoL dimensions. Conclusions: IMRT results in a significant reduction of patient- and observer-rated xerostomia, as well as other head and neck symptoms, compared with standard 3D-CRT. These differences translate into a significant improvement of the more general dimensions of HRQoL.

  20. Standard software for CAMAC

    International Nuclear Information System (INIS)

    Lenkszus, F.R.

    1978-01-01

    The NIM Committee (National Instrumentation Methods Committee) of the U.S. Department of Energy and the ESONE Committee of European Laboratories have jointly specified standard software for use with CAMAC. Three general approaches were followed: the definition of a language called IML for use in CAMAC systems, the definition of a standard set of subroutine calls, and real-time extensions to the BASIC language. This paper summarizes the results of these efforts. 1 table

  1. Standard dilution analysis.

    Science.gov (United States)

    Jones, Willis B; Donati, George L; Calloway, Clifton P; Jones, Bradley T

    2015-02-17

    Standard dilution analysis (SDA) is a novel calibration method that may be applied to most instrumental techniques that will accept liquid samples and are capable of monitoring two wavelengths simultaneously. It combines the traditional methods of standard additions and internal standards. Therefore, it simultaneously corrects for matrix effects and for fluctuations due to changes in sample size, orientation, or instrumental parameters. SDA requires only 200 s per sample with inductively coupled plasma optical emission spectrometry (ICP OES). Neither the preparation of a series of standard solutions nor the construction of a universal calibration graph is required. The analysis is performed by combining two solutions in a single container: the first containing 50% sample and 50% standard mixture; the second containing 50% sample and 50% solvent. Data are collected in real time as the first solution is diluted by the second one. The results are used to prepare a plot of the analyte-to-internal standard signal ratio on the y-axis versus the inverse of the internal standard concentration on the x-axis. The analyte concentration in the sample is determined from the ratio of the slope and intercept of that plot. The method has been applied to the determination of FD&C dye Blue No. 1 in mouthwash by molecular absorption spectrometry and to the determination of eight metals in mouthwash, wine, cola, nitric acid, and water by ICP OES. Both the accuracy and precision for SDA are better than those observed for the external calibration, standard additions, and internal standard methods using ICP OES.

  2. Fiscal 1997 report on the results of the international standardization R and D. Study of the international standardization by the economic evaluation of environmental impacts; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Kankyo compact no keizai hyoka ni yoru kokusai hyojunka no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    For the purpose of the international standardization, conducted was a R and D of `the economic evaluation method of environmental impacts.` Survey/analysis were conducted of the trends in the U.S. and Europe where the study on environmental costs is advancing, and study systems were constructed in cooperation with Resources for the Future (RFF), the U.S. Electric Power Research Institute, the University of London, etc. As to impact analysis models, the development of environmental excrement transfer models has been finished, and the development of D-R relational equations which reflected characteristics in Japan has been started. In the joint study with the U.S. RFF, conducted were survey/analysis using the CVM (contingent valuation method). By the comparison of the survey data with actual medical data and comparison with the economic value conversion method, etc., validity and consistency of the CVM method were verified. As a result, it was found that these survey data could be explained without inconsistency. A case study of the environmental cost evaluation was made for electric power, iron/steel and electricity, and it was verified that this developmental method was fully applicable to the environmental impact evaluation of the actual production system. 27 refs., 33 figs., 89 tabs.

  3. Fiscal 1997 report on the results of the international standardization R and D. Quantification of the sensory evaluation and international standardization in the paint field; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Toryo bun`ya ni okeru kanno hyoka no teiryoka to kokusai hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    Japanese paint users demand products of higher-quality than users in the U.S. and Europe, and therefore, paint makeres in Japan are making strenuous efforts to improve the product quality in terms of homogeneity, appearence and durability of the surface of paint films. However, the evaluation of paint surfaces is conducted by the qualitative sensory evaluation, resulting in obtaining no appropriate evaluation. Accordingly, the following were developed as new evaluation methods which give rational and economical indicators, contribute to shortening of the period for development of new products, and aim at the international standardization: 1) quantitative evaluation of the paint drying process; 2) image analysis of the degraded part of paint films; 3) surface analysis of paint films. In 1), a kinetic friction measuring quantitative evaluation of the surface of paint films was developed. In 2), the development of an exclusive program by the image analysis made the quantitative evaluation with high accuracy/reliability possible. In 3), an evaluation method was developed in which differences among the specimens can be detected by the chemiluminescent measurement in an extremely early stage of exposure when the gloss change just begins. As to the chalking, a new evaluation was developed in which the degree of chalking can quantitatively be evaluated by attaching a special adhesion tape to the degraded part of paint films and by the optical measurement of the degree of transparency. 101 refs., 341 figs., 118 tabs.

  4. Fiscal 1997 report on the results of the international standardization R and D. Standardization of the optical evaluation method of the performance of shape stability of the apparel; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Apareru seihin no keitai antei seino no kogakuteki hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    For the purpose of proposing the optical evaluation method of appearance of the apparel as an international standard, studies were made of the following: 3D determination/assessment method, development of mannequin holders, development of shape-retentive cubic replicas, washing/drying conditions, etc. As to the shape retention, cubic replicas for collars and cuffs were manufactured and inputted as image data. Besides, as to the evaluation items such as wrinkles, seam-puckering and pleats, the class determining algorithm was made by comparison between the measuring data and the results of the human-sight measurement. These were embodied into mannequin holders and integrated into the optical 3D instrumental system, which was discussed as a 3D determination/assessment system. By the development of the 3D measuring system and image analysis program, a comprehensive evaluation system was developed which can determine/assess the performance of shape stability of the apparel optically as absolute evaluation. This method will be internationally proposed as an optical evaluation method of the appearance of the apparel. 86 figs., 8 tabs.

  5. The Dynamics of Standardization

    DEFF Research Database (Denmark)

    Brunsson, Nils; Rasche, Andreas; Seidl, David

    2012-01-01

    This paper suggests that when the phenomenon of standards and standardization is examined from the perspective of organization studies, three aspects stand out: the standardization of organizations, standardization by organizations and standardization as (a form of) organization. Following a comp...

  6. Standardization of depression measurement

    DEFF Research Database (Denmark)

    Wahl, Inka; Löwe, Bernd; Bjørner, Jakob

    2014-01-01

    OBJECTIVES: To provide a standardized metric for the assessment of depression severity to enable comparability among results of established depression measures. STUDY DESIGN AND SETTING: A common metric for 11 depression questionnaires was developed applying item response theory (IRT) methods. Data...... of 33,844 adults were used for secondary analysis including routine assessments of 23,817 in- and outpatients with mental and/or medical conditions (46% with depressive disorders) and a general population sample of 10,027 randomly selected participants from three representative German household surveys....... RESULTS: A standardized metric for depression severity was defined by 143 items, and scores were normed to a general population mean of 50 (standard deviation = 10) for easy interpretability. It covers the entire range of depression severity assessed by established instruments. The metric allows...

  7. Sequential Combination of Gemtuzumab Ozogamicin and Standard Chemotherapy in Older Patients With Newly Diagnosed Acute Myeloid Leukemia: Results of a Randomized Phase III Trial by the EORTC and GIMEMA Consortium (AML-17).

    NARCIS (Netherlands)

    Amadori, S.; Suciu, S.; Stasi, R.; Salih, H.R.; Selleslag, D.; Muus, P.; Fabritiis, P. De; Venditti, A.; Ho, A.D.; Lubbert, M.; Thomas, X.; Latagliata, R.; Halkes, C.J.; Falzetti, F.; Magro, D.; Guimaraes, J.E.; Berneman, Z.; Specchia, G.; Karrasch, M.; Fazi, P.; Vignetti, M.; Willemze, R.; Witte, T.J. de; Marie, J.P.

    2013-01-01

    PURPOSE: This randomized trial evaluated the efficacy and toxicity of sequential gemtuzumab ozogamicin (GO) and standard chemotherapy in older patients with newly diagnosed acute myeloid leukemia (AML). PATIENTS AND METHODS: Patients (n = 472) age 61 to 75 years were randomly assigned to induction

  8. MR imaging for examination of the heart and the great arteria: Clinical results obtained with a 1.0 Tesla standard system; MR-Tomographie des Herzens und der grossen Arterien: Klinische Erfahrungen mit einem 1,0 Tesla Standard-System

    Energy Technology Data Exchange (ETDEWEB)

    Koch, J.A.; Poll, L.W.; Moedder, U. [Institut fuer Diagnostische Radiologie, Duesseldorf Univ. (Germany); Feindt, P. [Klinik fuer Thorax- und Kardiovaskulaere Chirurgie, Duesseldorf Univ. (Germany); Godehardt, E. [Klinik fuer Thorax- und Kardiovaskulaere Chirurgie, Sektion Biostatistik, Duesseldorf Univ. (Germany); Schwartzkopff, B. [Klinik fuer Kardiologie und Pneumologie, Duesseldorf Univ. (Germany)

    2000-02-01

    The potentials of the cardio-MR imaging method will be increasingly better exploited in future also with less sophisticated, standard systems. The method yields high-quality information, is of low discomfort for the patients, easy to apply, and cost and time-effective at that. (orig./CB) [German] Das Potenzial der Kardio-MR wird sich auch an Standard-Geraeten immer weiter ausschoepfen lassen. Sie hat hohe Aussagekraft, belastet den Patienten wenig, ist leicht handhabbar, kosten- und zeiteffektiv. (orig.)

  9. Standards and (self)implosion

    DEFF Research Database (Denmark)

    Brøgger, Katja; Staunæs, Dorthe

    2016-01-01

    Standards is an interesting phenomenon in discussions on emotional circulation and subjectivities. Because standards do travel. And they are usually on a mission: to standardize policies or products and consequently also those who are administered by them or consume them. Literature on the spread...... of standards often tends to conceptualize the travelling of standards as contagious processes resulting in epidemic spreads. In this article, the abstract metaphor of epidemic spread is replaced by an analytical configuration of a new mode of educational governance in which orchestrating webs of incentives...... and anticipations is a major driver. New international standards is propelled by material-affective infrastructures and the embodied interpretations that, educational agents and organizations make of them. The article displays how standards makes organizations and selves implode and how the impact of standardizing...

  10. Conference: STANDARD MODEL @ LHC

    CERN Multimedia

    2012-01-01

    HCØ institute Universitetsparken 5 DK-2100 Copenhagen Ø Denmark Room: Auditorium 2 STANDARD MODEL @ LHC Niels Bohr International Academy and Discovery Center 10-13 April 2012 This four day meeting will bring together both experimental and theoretical aspects of Standard Model phenomenology at the LHC. The very latest results from the LHC experiments will be under discussion. Topics covered will be split into the following categories:     * QCD (Hard,Soft & PDFs)     * Vector Boson production     * Higgs searches     * Top Quark Physics     * Flavour physics

  11. Is a nurse-led telephone intervention a viable alternative to nurse-led home care and standard care for patients receiving oral capecitabine? Results from a large prospective audit in patients with colorectal cancer.

    Science.gov (United States)

    Craven, Olive; Hughes, Carol Anne; Burton, Amy; Saunders, Mark P; Molassiotis, Alex

    2013-05-01

    Home care nursing has been shown to be a valuable service for patients receiving oral chemotherapy; however, associated costs can be high and telephone-based services may be more cost-effective options. This prospective audit explored the usefulness of a nurse-led telephone intervention for supporting cancer patients treated with Capecitabine, comparing historical findings from a randomised trial evaluating a home-based intervention over standard care with a modified nurse-led telephone follow-up intervention. Self-reported toxicity and service use were assessed in 298 patients who received nurse-led telephone follow-up, compared with historical data from 164 patients (81 receiving standard care and 83 home care intervention). Findings suggested that nurse-led telephone follow-up can potentially lead to reduced toxicity (chest pain, vomiting, oral mucositis, nausea, insomnia) when compared with standard care, and that it has a similar impact on the management of some symptoms when compared with home care (i.e. vomiting, oral mucositis), although it was not as effective as the home care intervention for other toxicities (diarrhoea and insomnia). These encouraging findings need to be explored further using a randomised trial design before we reach any conclusions. Further research should also include a health economics study to assess the cost-effectiveness of the telephone-based services for patients receiving oral chemotherapy. © 2013 Blackwell Publishing Ltd.

  12. GAIA Service and Standard Assessment

    DEFF Research Database (Denmark)

    Dormann, Claire; Øst, Alexander Gorm

    A delivery from the ACTS-project GAIA. The report validates the gAIA architecture and standard. It provides results concerning the deployment of distributed brokerage systems over broadband networks.......A delivery from the ACTS-project GAIA. The report validates the gAIA architecture and standard. It provides results concerning the deployment of distributed brokerage systems over broadband networks....

  13. Safety and efficacy of insulin degludec/insulin aspart with bolus mealtime insulin aspart compared with standard basal?bolus treatment in people with Type 1 diabetes: 1?year results from a randomized clinical trial (BOOST ? T1)

    OpenAIRE

    Hirsch, I. B.; Franek, E.; Mersebach, H.; Bardtrum, L.; Hermansen, K.

    2016-01-01

    Abstract Aims To evaluate the long?term safety and efficacy of a simplified basal?bolus regimen of once?daily insulin degludec/insulin aspart (IDegAsp) with additional IAsp vs. a standard basal?bolus insulin regimen of insulin detemir (IDet) with IAsp in adults with Type 1 diabetes. Methods This was an open?label trial comprising a 26?week core phase followed by a 26?week extension phase. Participants were randomized to IDegAsp once daily at the main meal and IAsp at remaining meals (IDegAsp+...

  14. Prospective, Longitudinal Assessment of Quality of Life in Children from Diagnosis to Three Months off Treatment for Standard Risk (SR) Acute Lymphoblastic Leukemia (ALL): Results of Children's Oncology Group Study AALL0331

    OpenAIRE

    Mitchell, Hannah-Rose; Lu, Xiaomin; Myers, Regina M.; Sung, Lillian; Balsamo, Lyn M.; Carroll, William L.; Raetz, Elizabeth; Loh, Mignon L.; Mattano, Leonard A.; Winick, Naomi J.; Devidas, Meenakshi; Hunger, Stephen P.; Maloney, Kelly; Kadan-Lottick, Nina S.

    2015-01-01

    Standard risk acute lymphoblastic leukemia (SR-ALL) has high cure rates, but requires two to three years of therapy. We aimed to 1) prospectively evaluate health-related quality of life (HRQOL) during and after SR-ALL therapy, and 2) identify associated predictors. Parents of 160 SR-ALL patients enrolled on Children's Oncology Group (COG) therapeutic trial AALL0331 at 31 sites completed the Pediatric Quality of Life Inventory (PedsQL) 4.0 Generic Core Scales (physical, emotional, and social f...

  15. Fiscal 1997 report on the results of the international standardization R and D. R and D of the standardization of a method to test acceleration life of phosphorous acid fuel cells; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Rinsangata nenryo denchi no kasoku jumyo shiken hoho no hyojunka ni kansuru kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    As for fuel cells, which are expected as a new clean energy, the R and D are being proceeded with in various fields of the world, but the standardization has not been made both in Japan and abroad. In Japan, the situation is that the information on technical terms, indication method, performance test method, and environment/safety test methods of the phosphorous acid fuel cell power generation is publicly spread. In relation to the international promotion of fuel cells to be predicted, it is necessary to internationally standardize cells themselves which are a key component of fuel cell power generation facilities. Phosphorous acid fuel cells are expected of the earliest commercialization of all, but the common test method to evaluate life characteristics of the cell stack has not been established yet. In the R and D, for the purpose of internationally standardizing test methods to evaluate life characteristics of the cell stack, a study on the acceleration life test method of phosphoric acid fuel cells was conducted in terms of the technical trend, data, standard, etc. A plan was prepared on general rules of the method to test acceleration life at the cell reaction part of the small cell, and activities also were started for setting up a technical committee for the fuel cell power system in President`s Advisory Committee on Future Technology. 29 figs., 20 tabs.

  16. Nivolumab versus standard, single-agent therapy of investigator's choice in recurrent or metastatic squamous cell carcinoma of the head and neck (CheckMate 141): health-related quality-of-life results from a randomised, phase 3 trial.

    Science.gov (United States)

    Harrington, Kevin J; Ferris, Robert L; Blumenschein, George; Colevas, A Dimitrios; Fayette, Jérôme; Licitra, Lisa; Kasper, Stefan; Even, Caroline; Vokes, Everett E; Worden, Francis; Saba, Nabil F; Kiyota, Naomi; Haddad, Robert; Tahara, Makoto; Grünwald, Viktor; Shaw, James W; Monga, Manish; Lynch, Mark; Taylor, Fiona; DeRosa, Michael; Morrissey, Laura; Cocks, Kim; Gillison, Maura L; Guigay, Joël

    2017-08-01

    Patients with platinum-refractory recurrent or metastatic squamous cell carcinoma of the head and neck have few treatment options and poor prognosis. Nivolumab significantly improved survival of this patient population when compared with standard single-agent therapy of investigator's choice in Checkmate 141; here we report the effect of nivolumab on patient-reported outcomes (PROs). CheckMate 141 was a randomised, open-label, phase 3 trial in patients with recurrent or metastatic squamous cell carcinoma of the head and neck who progressed within 6 months after platinum-based chemotherapy. Patients were randomly assigned (2:1) to nivolumab 3 mg/kg every 2 weeks (n=240) or investigator's choice (n=121) of methotrexate (40-60 mg/m 2 of body surface area), docetaxel (30-40 mg/m 2 ), or cetuximab (250 mg/m 2 after a loading dose of 400 mg/m 2 ) until disease progression, intolerable toxicity, or withdrawal of consent. On Jan 26, 2016, the independent data monitoring committee reviewed the data at the planned interim analysis and declared overall survival superiority for nivolumab over investigator's choice therapy (primary endpoint; described previously). The protocol was amended to allow patients in the investigator's choice group to cross over to nivolumab. All patients not on active therapy are being followed for survival. As an exploratory endpoint, PROs were assessed at baseline, week 9, and every 6 weeks thereafter using the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire-Core 30 (QLQ-C30), the EORTC head and neck cancer-specific module (EORTC QLQ-H&N35), and the three-level European Quality of Life-5 Dimensions (EQ-5D) questionnaire. Differences within and between treatment groups in PROs were analysed by ANCOVA among patients with baseline and at least one other assessment. All randomised patients were included in the time to clinically meaningful deterioration analyses. Median time to clinically meaningful

  17. Methodology, results and experience of independent brachytherapy plan verifications based on DICOM standard; Implementacion, resultados y experiencia de una verificacion independiente de tratamientos de braquiterapia basada en el estandar DICOM

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando Sanchez, A.; Pardo Perez, E.; Castro Novals, J.; Casa de Julian, M. A. de la; Cabello Murillo, E.; Diaz Fuentes, R.; Molina Lopez, M. Y.

    2013-09-01

    The use of a high dose rate source together with an afterloading treatment delivery in brachytherapy plans allows for dose modulation minimizing dose to staff. An independent verification of the exported data to the treatment station is required by local regulations (being also a widely accepted recommendation on the international literature). We have developed a methodology under home brew code to import DICOM treatment data onto an Excel spreadsheet that is able to calculate dose on given reference points using the TG-43 formalism of the AAPM3-5. It employs analytic fits of anisotropy factor and radial dose function for different sources. The end point implementations we present here allow merging in one step an independent verification and a treatment printout. The use of DICOM standard makes our code versatile and provides greater compatibility with respect to current treatment planning systems. (Author)

  18. Survival, safety, and prognostic factors for outcome with Regorafenib in patients with metastatic colorectal cancer refractory to standard therapies: results from a multicenter study (REBACCA) nested within a compassionate use program

    International Nuclear Information System (INIS)

    Adenis, Antoine; Fouchardiere, Christelle de la; Paule, Bernard; Burtin, Pascal; Tougeron, David; Wallet, Jennifer; Dourthe, Louis-Marie; Etienne, Pierre-Luc; Mineur, Laurent; Clisant, Stéphanie; Phelip, Jean-Marc; Kramar, Andrew; Andre, Thierry

    2016-01-01

    Randomized trials have shown a survival benefit for regorafenib over placebo in patients with metastatic colorectal cancer (mCRC) that progressed after standard therapies. We evaluated survival and safety outcomes in patients treated with regorafenib in a real-life setting. REBECCA is a cohort study nested within a compassionate use program designed to evaluate survival, safety, and potential prognostic factors for outcome associated with regorafenib in patients with mCRC refractory to standard therapies. Treatment effects according to various patient and tumour characteristics were evaluated using univariate and multivariate Cox proportional hazards regression models. Of 1178 patients in the compassionate use program, 654 were in the full analysis set. Median follow-up was 16.5 months. Median survival was 5.6 months. The 12-month survival rate was 22 %. Survival was independently and unfavourably affected by the following variables: poor performance status, short time from initial diagnosis of metastases to the start of regorafenib, low initial regorafenib dose, >3 metastatic sites, presence of liver metastases, and KRAS mutations. We identified prognostic groups of patients with low, intermediate, and high risk of death, with a median survival of 9.2, 5.2, and 2.5 months, respectively. Five-hundred-twenty-four patients (80 %) experienced at least one regorafenib-related adverse event, most commonly, fatigue, hand-foot skin reaction, diarrhea, anorexia, arterial hypertension, and mucositis. The safety and efficacy profile of regorafenib in REBECCA are similar to those in randomized trials. Our prognostic model identified subgroups of mCRC patients who derived a minimal and maximum benefit from regorafenib. Clinicaltrials.gov: NCT02310477

  19. Safety and efficacy of insulin degludec/insulin aspart with bolus mealtime insulin aspart compared with standard basal-bolus treatment in people with Type 1 diabetes: 1-year results from a randomized clinical trial (BOOST®T1).

    Science.gov (United States)

    Hirsch, I B; Franek, E; Mersebach, H; Bardtrum, L; Hermansen, K

    2017-02-01

    To evaluate the long-term safety and efficacy of a simplified basal-bolus regimen of once-daily insulin degludec/insulin aspart (IDegAsp) with additional IAsp vs. a standard basal-bolus insulin regimen of insulin detemir (IDet) with IAsp in adults with Type 1 diabetes. This was an open-label trial comprising a 26-week core phase followed by a 26-week extension phase. Participants were randomized to IDegAsp once daily at the main meal and IAsp at remaining meals (IDegAsp+IAsp), or IDet (once or twice daily) and IAsp at all meals (IDet+IAsp). Insulins were titrated to target plasma glucose of IAsp). After 52 weeks, the overall confirmed hypoglycaemia rate was 31.8 episodes/patient-years of exposure (PYE) with IDegAsp+Asp and 36.7 episodes/PYE with IDet+IAsp, and the rate of nocturnal confirmed hypoglycaemia was significantly lower with IDegAsp+Asp than with IDet+IAsp (3.1 vs. 5.4 episodes/PYE, respectively; P IAsp) and 0.6% (IDet+IAsp), achieving 60 or 61 mmol/mol (7.6% or 7.7%, respectively), at Week 52. The mean total daily insulin dose was lower with IDegAsp+IAsp than with IDet+IAsp (ratio: 0.87; 95% CI 0.79-0.95; P = 0.0026). Once-daily treatment with IDegAsp and IAsp as bolus insulin for remaining meals was associated with significantly lower risk of nocturnal confirmed hypoglycaemia, improved glycaemic control and showed non-inferiority compared with IDet+IAsp, the standard of care in Type 1 diabetes. © 2016 The Authors Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.

  20. Standards for Standardized Logistic Regression Coefficients

    Science.gov (United States)

    Menard, Scott

    2011-01-01

    Standardized coefficients in logistic regression analysis have the same utility as standardized coefficients in linear regression analysis. Although there has been no consensus on the best way to construct standardized logistic regression coefficients, there is now sufficient evidence to suggest a single best approach to the construction of a…

  1. Vocational High School Effectiveness Standard ISO 9001: 2008 for Achievement Content Standards, Standard Process and Competency Standards Graduates

    Directory of Open Access Journals (Sweden)

    Yeni Ratih Pratiwi

    2014-06-01

    Full Text Available Efektivitas Sekolah Menengah Kejuruan Berstandar ISO 9001:2008 terhadap Pencapaian Standar Isi, Standar Proses dan Standar Kompetensi Lulusan Abstract: The purpose of this study was to determine differences in the effectiveness of the achievement of the content standards, process standards, and competency standards in vocational already standard ISO 9001: 2008 with CMS that has not been standardized ISO 9001: 2008 both in public schools and private schools. Data collection using the questionnaire enclosed Likert scale models. Analysis of data using one-way ANOVA using SPSS. The results showed: (1 there is no difference in effectiveness between public SMK ISO standard ISO standards with private SMK (P = 0.001; (2 there are differences in the effectiveness of public SMK SMK ISO standards with ISO standards have not (P = 0.000; (3 there are differences in the effectiveness of public SMK ISO standards with private vocational yet ISO standards (P = 0.000; (4 there are differences in the effectiveness of the private vocational school with vocational standard ISO standard ISO country has not (P = 0.015; (5 there are differences in the effectiveness of the private vocational bertandar ISO with private vocational yet standardized ISO (P = 0.000; (6 there was no difference in the effectiveness of public SMK has not been standardized by the ISO standard ISO private SMK yet. Key Words: vocational high school standards ISO 9001: 2008, the standard content, process standards, competency standards Abstrak: Tujuan penelitian ini untuk mengetahui perbedaan efektivitas pencapaian standar isi, standar proses, dan standar kompetensi lulusan pada SMK yang sudah berstandar ISO 9001:2008 dengan SMK yang belum berstandar ISO 9001:2008 baik pada sekolah negeri maupun sekolah swasta. Pengumpulan data menggunakan kuisioner tertutup model skala likert. Analisis data menggunakan ANOVA one way menggunakan program SPSS. Hasil penelitian menunjukkan: (1 ada perbedaan

  2. Impact of a combined multimodal-aerobic and multimodal intervention compared to standard aerobic treatment in breast cancer survivors with chronic cancer-related fatigue - results of a three-armed pragmatic trial in a comprehensive cohort design.

    Science.gov (United States)

    Kröz, Matthias; Reif, Marcus; Glinz, Augustina; Berger, Bettina; Nikolaou, Andreas; Zerm, Roland; Brinkhaus, Benno; Girke, Matthias; Büssing, Arndt; Gutenbrunner, Christoph

    2017-03-02

    Cancer-related fatigue (CRF) and insomnia are major complaints in breast cancer survivors (BC). Aerobic training (AT), the standard therapy for CRF in BC, shows only minor to moderate treatment effects. Other evidence-based treatments include cognitive behavioral therapy, e.g., sleep education/restriction (SE) and mindfulness-based therapies. We investigated the effectiveness of a 10-week multimodal program (MT) consisting of SE, psycho-education, eurythmy- and painting-therapy, administered separately or in combination with AT (CT) and compared both arms to AT alone. In a pragmatic comprehensive cohort study BC with chronic CRF were allocated randomly or by patient preference to (a) MT, (b) CT (MT + AT) or (c) AT alone. Primary endpoint was a composite score of the Pittsburgh Sleep Quality Index and the Cancer Fatigue Scale after 10 weeks of intervention (T1); a second endpoint was a follow-up assessment 6 months later (T2). The primary hypothesis stated superiority of CT and non-inferiority of MT vs. AT at T1. A closed testing procedure preserved the global α-level. The intention-to-treat analysis included propensity scores for the mode of allocation and for the preferred treatment, respectively. Altogether 126 BC were recruited: 65 were randomized and 61 allocated by preference; 105 started the intervention. Socio-demographic parameters were generally balanced at baseline. Non-inferiority of MT to AT at T1 was confirmed (p < 0.05), yet the confirmative analysis stopped as it was not possible to confirm superiority of CT vs. AT (p = 0.119). In consecutive exploratory analyses MT and CT were superior to AT at T1 and T2 (MT) or T2 alone (CT), respectively. The multimodal CRF-therapy was found to be confirmatively non-inferior to standard therapy and even yielded exploratively sustained superiority. A randomized controlled trial including a larger sample size and a longer follow-up to evaluate multimodal CRF-therapy is highly warranted. DRKS-ID: DRKS

  3. Malaysian NDT standards

    International Nuclear Information System (INIS)

    Khazali Mohd Zin

    2001-01-01

    In order to become a developed country, Malaysia needs to develop her own national standards. It has been projected that by the year 2020, Malaysia requires about 8,000 standards (Department of Standard Malaysia). Currently more than 2,000 Malaysian Standards have been gazette by the government which considerably too low before tire year 2020. NDT standards have been identified by the standard working group as one of the areas to promote our national standards. In this paper the author describes the steps taken to establish the Malaysian very own NDT standards. The project starts with the establishment of radiographic standards. (Author)

  4. Multiparametric voxel-based analyses of standardized uptake values and apparent diffusion coefficients of soft-tissue tumours with a positron emission tomography/magnetic resonance system: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Sagiyama, Koji; Kamei, Ryotaro; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Watanabe, Yuji; Kawanami, Satoshi [Kyushu University, Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Fukuoka (Japan); Hong, Sungtak [Philips Electronics Japan, Healthcare, Tokyo (Japan); Matsumoto, Yoshihiro [Kyushu University, Departmant of Orthopaedic Surgery, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-12-15

    To investigate the usefulness of voxel-based analysis of standardized uptake values (SUVs) and apparent diffusion coefficients (ADCs) for evaluating soft-tissue tumour malignancy with a PET/MR system. Thirty-five subjects with either ten low/intermediate-grade tumours or 25 high-grade tumours were prospectively enrolled. Zoomed diffusion-weighted and fluorodeoxyglucose ({sup 18}FDG)-PET images were acquired along with fat-suppressed T2-weighted images (FST2WIs). Regions of interest (ROIs) were drawn on FST2WIs including the tumour in all slices. ROIs were pasted onto PET and ADC-maps to measure SUVs and ADCs within tumour ROIs. Tumour volume, SUVmax, ADCminimum, the heterogeneity and the correlation coefficients of SUV and ADC were recorded. The parameters of high- and low/intermediate-grade groups were compared, and receiver operating characteristic (ROC) analysis was also performed. The mean correlation coefficient for SUV and ADC in high-grade sarcomas was lower than that of low/intermediate-grade tumours (-0.41 ± 0.25 vs. -0.08 ± 0.34, P < 0.01). Other parameters did not differ significantly. ROC analysis demonstrated that correlation coefficient showed the best diagnostic performance for differentiating the two groups (AUC 0.79, sensitivity 96.0%, specificity 60%, accuracy 85.7%). SUV and ADC determined via PET/MR may be useful for differentiating between high-grade and low/intermediate-grade soft tissue tumours. (orig.)

  5. A tailored-guided internet-based cognitive-behavioral intervention for patients with rheumatoid arthritis as an adjunct to standard rheumatological care: results of a randomized controlled trial.

    Science.gov (United States)

    Ferwerda, Maaike; van Beugen, Sylvia; van Middendorp, Henriët; Spillekom-van Koulil, Saskia; Donders, A Rogier T; Visser, Henk; Taal, Erik; Creemers, Marjonne C W; van Riel, Piet C L M; Evers, Andrea W M

    2017-05-01

    For patients with chronic pain conditions such as rheumatoid arthritis (RA), who experience elevated levels of distress, tailored-guided internet-based cognitive-behavioral treatment may be effective in improving psychological and physical functioning, and reducing the impact of RA on daily life. A multicenter, randomized controlled trial was conducted for RA patients with elevated levels of distress as assessed by a disease-specific measure. The control group (n = 71) received standard care and the intervention group (n = 62) additionally received an internet-based tailored cognitive-behavioral intervention. Main analyses were performed using a linear mixed model estimating differences between the intervention and control groups in scores of psychological functioning, physical functioning, and impact of RA on daily life at preassesment and postassessment, and at 3, 6, 9, and 12 months. Patients who received the internet-based intervention reported a larger improvement in psychological functioning compared with the control group, indicating less depressed mood (P physical functioning, a trend was found for the intervention group reporting less fatigue than the control group (P = 0.06, d = 0.24), whereas no effect was found on pain. No effects were found for the impact of RA on daily life, except for the intervention group experiencing fewer role limitations due to emotional problems (P therapy is a promising development to aid patients with psychological distress particularly in improving psychological functioning. Further research on adherence and specific intervention ingredients is warranted.

  6. Increased Cross-Gender Identification Independent of Gender Role Behavior in Girls with Congenital Adrenal Hyperplasia: Results from a Standardized Assessment of 4- to 11-Year-Old Children.

    Science.gov (United States)

    Pasterski, Vickie; Zucker, Kenneth J; Hindmarsh, Peter C; Hughes, Ieuan A; Acerini, Carlo; Spencer, Debra; Neufeld, Sharon; Hines, Melissa

    2015-07-01

    While reports showing a link between prenatal androgen exposure and human gender role behavior are consistent and the effects are robust, associations to gender identity or cross-gender identification are less clear. The aim of the current study was to investigate potential cross-gender identification in girls exposed prenatally to high concentrations of androgens due to classical congenital adrenal hyperplasia (CAH). Assessment included two standardized measures and a short parent interview assessing frequency of behavioral features of cross-gender identification as conceptualized in Part A of the diagnostic criteria for gender identity disorder (GID) in the DSM-IV-TR. Next, because existing measures may have conflated gender role behavior with gender identity and because the distinction is potentially informative, we factor analyzed items from the measures which included both gender identity and gender role items to establish the independence of the two constructs. Participants were 43 girls and 38 boys with CAH and 41 unaffected female and 31 unaffected male relatives, aged 4- to 11-years. Girls with CAH had more cross-gender responses than female controls on all three measures of cross-gender identification as well as on a composite measure of gender identity independent of gender role behavior. Furthermore, parent report indicated that 5/39 (12.8 %) of the girls with CAH exhibited cross-gender behavior in all five behavioral domains which comprise the cross-gender identification component of GID compared to 0/105 (0.0 %) of the children in the other three groups combined. These data suggest that girls exposed to high concentrations of androgens prenatally are more likely to show cross-gender identification than girls without CAH or boys with and without CAH. Our findings suggest that prenatal androgen exposure could play a role in gender identity development in healthy children, and may be relevant to gender assignment in cases of prenatal hormone disruption

  7. Single-incision laparoscopic surgery using colon-lifting technique for colorectal cancer: a matched case-control comparison with standard multiport laparoscopic surgery in terms of short-term results and access instrument cost.

    Science.gov (United States)

    Fujii, Shoichi; Watanabe, Kazuteru; Ota, Mitsuyoshi; Watanabe, Jun; Ichikawa, Yasushi; Yamagishi, Shigeru; Tatsumi, Kenji; Suwa, Hirokazu; Kunisaki, Chikara; Taguri, Masataka; Morita, Satoshi; Endo, Itaru

    2012-05-01

    Single-incision laparoscopic surgery (SILS) has been used for colorectal cancer as a minimally invasive procedure. However, there are still difficulties concerning effective triangulation and countertraction. The study's purpose was to clarify the usefulness of the colon-lifting technique (CLT) in SILS for colorectal cancer. SILS was performed for cancer (cT2N0 or less) of the right-sided colon (near the ileocecum), sigmoid, or rectosigmoid. The SILS™ Port was used for transumbilical access. A suture string was inserted through the abdominal wall and passed through the mesocolon. The colon was retracted anteriorly and fixed to the abdominal wall. The main mesenteric vessels were placed under tension. Lymph node dissection was performed by medial approach. Short-term surgical outcomes and access port costs were compared between SILS (using CLT) and the standard multiport technique (MPT). The two groups were case-matched by propensity scoring. Analyzed variables included preoperative Dukes stage and tumor location. From June 2009 to April 2011, 27 patients underwent SILS, and from April 2005 to April 2011, 85 patients underwent MPT. Propensity scoring generated 23 matched patients per group for SILS versus MPT comparisons. There were no significant differences in operating time, blood loss, early complications, postoperative analgesic frequency, or length of hospital stay. One MPT patient was converted to open surgery (4.5%); no SILS patients were converted. There were no significant differences in the length of distal cut margin and the number of harvested lymph nodes, except incision length (SILS vs. MPT: 33 vs. 55 mm, P Japanese yen, P CLT was safe and effective in providing radical treatment of cT2N0 cancer in the right-sided colon, sigmoid, or rectosigmoid. SILS was advantageous with respect to cosmesis and lower cost of access instruments.

  8. Prospective, longitudinal assessment of quality of life in children from diagnosis to 3 months off treatment for standard risk acute lymphoblastic leukemia: Results of Children's Oncology Group study AALL0331.

    Science.gov (United States)

    Mitchell, Hannah-Rose; Lu, Xiaomin; Myers, Regina M; Sung, Lillian; Balsamo, Lyn M; Carroll, William L; Raetz, Elizabeth; Loh, Mignon L; Mattano, Leonard A; Winick, Naomi J; Devidas, Meenakshi; Hunger, Stephen P; Maloney, Kelly; Kadan-Lottick, Nina S

    2016-01-15

    Standard risk acute lymphoblastic leukemia (SR-ALL) has high cure rates, but requires 2-3 years of therapy. We aimed to (i) prospectively evaluate health-related quality of life (HRQOL) during and after SR-ALL therapy, and (ii) identify associated predictors. Parents of 160 SR-ALL patients enrolled on Children's Oncology Group (COG) therapeutic trial AALL0331 at 31 sites completed the Pediatric Quality of Life Inventory (PedsQL) 4.0 Generic Core Scales (physical, emotional and social functioning) and Family Assessment Device-General Functioning (FAD-GF) at 1, 6 and 12 months after diagnosis, and 3 months post-therapy. Mean PedsQL scores in physical, emotional and social functioning were impaired 1 month after diagnosis but steadily improved. Three months post-therapy, impaired physical and social functioning was observed in 27.8 and 25.8% of patients, respectively. In repeated-measures analysis, problematic family functioning predicted emotional (OR = 1.85, 95% CI 1.03-3.34) and social (OR = 1.99, 95% CI 1.21-3.27) impairment. Larger household size was associated with social impairment (OR = 1.21, 95% CI 1.02-1.45). Adverse neurological event(s) during therapy predicted post-therapy physical (OR = 5.17, 95% CI 1.61-16.63) and social (OR = 8.17, 95% CI 1.19-56.16) impairment. HRQOL 1 month after diagnosis was not predictive of HRQOL 3 months after therapy completion. In conclusion, children with SR-ALL experience considerable impairment in HRQOL at the end of induction, but rapidly improve. However, many still experience physical and social impairment 3 months post-therapy, suggesting a role for continued family and physical functioning support. Longer follow-up is needed to determine if post-therapy deficits change over time. © 2015 UICC.

  9. The International Standards Organisation offshore structures standard

    International Nuclear Information System (INIS)

    Snell, R.O.

    1994-01-01

    The International Standards Organisation has initiated a program to develop a suite of ISO Codes and Standards for the Oil Industry. The Offshore Structures Standard is one of seven topics being addressed. The scope of the standard will encompass fixed steel and concrete structures, floating structures, Arctic structures and the site specific assessment of mobile drilling and accommodation units. The standard will use as base documents the existing recommended practices and standards most frequently used for each type of structure, and will develop them to incorporate best published and recognized practice and knowledge where it provides a significant improvement on the base document. Work on the Code has commenced under the direction of an internationally constituted sub-committee comprising representatives from most of the countries with a substantial offshore oil and gas industry. This paper outlines the background to the code and the format, content and work program

  10. Fiscal 1997 report on the results of the international standardization R and D. R and D of a mobile office system (R and D of next generation mobile business terminals); 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Mobile office system no kenkyu kaihatsu (jisedai keitai joho kiki no kenkyu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    This R and D is aimed firstly at trially developing next generation mobile business terminals (MBT) based on the technical standards of MBT of which the standards were completed in the fiscal 1996 R and D of Mobile Office Promotion Association (MOPA), secondly at developing an evaluation method for trial terminals and establishing the technical standards of MBT through data communication among different terminals and confirmation of application motions, and thirdly at promoting the international standardization. The study was conducted in the following procedures: 1) making of a comprehensive examination-standardization working group, determination of the use of trial terminals and the MBT evaluation method; 2) trial development of the MBT standards and prototypes; 3) study of the MBT evaluation method; 4) evaluation test on the prototypes; 5) comprehensive evaluation. As the fruit of the study, the evaluation/test specifications were completed, and the evaluation tests among different terminals were conducted. As a result of the evaluation test, the transplantation of MBT managers was done almost with no problems. The MBT adaptability evaluation test was also done almost without problems. 6 figs., 6 tabs.

  11. What is "Standard" About the Standard Deviation

    OpenAIRE

    Newberger, Florence; Safer, Alan M.; Watson, Saleem

    2010-01-01

    The choice of the formula for standard deviation is explained in elementary statistics textbooks in various ways. We give an explanation for this formula by representing the data as a vector in $\\mathbb R^n$ and considering its distance from a central tendency vector. In this setting the "standard" formula represents a shortest distance in the standard metric. We also show that different metrics lead to different measures of central tendency.

  12. Standard Reference Tables -

    Data.gov (United States)

    Department of Transportation — The Standard Reference Tables (SRT) provide consistent reference data for the various applications that support Flight Standards Service (AFS) business processes and...

  13. Energy labels and standards

    International Nuclear Information System (INIS)

    Newman, J.

    2000-01-01

    Improving energy efficiency at the end-use level is increasingly important as Climate Change commitments force policy makers to look for areas where greenhouse gas emissions reduction can be achieved rapidly. Indeed, although much improvement has been mode over the past 25 years, significant potential for improving energy efficiency still exists. Labelling and minimum efficiency standards for appliances and equipment have proven to be one of the most promising policy instruments. Used for many years in some IEA Member countries, they delivered tangible results. They are among the cheapest and least intrusive of policies. Policy makers cannot afford to neglect them. This book examines current and post experiences of countries using labels and standards to improve energy end-use efficiency. It identifies successful policy approaches, focusing on what works best. It also provides insight into the opportunities ahead, including the widespread use of computer chips in appliances, cars and equipment. This book should be of great help not only to administrations planning to introduce labelling schemes, but also to those in the process of strengthening their current programmes. Policy makers in developing countries will also find here all necessary justification for implementing labelling and standards in their economy. 74 refs

  14. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1994-06-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining licensees and applicants for reactor operator and senior reactor operator licenses at power reactor facilities pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). The Examiner Standards are intended to assist NRC examiners and facility licensees to better understand the initial and requalification examination processes and to ensure the equitable and consistent administration of examinations to all applicants. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator licensing policy changes. Revision 7 was published in January 1993 and became effective in August 1993. Supplement 1 is being issued primarily to implement administrative changes to the requalification examination program resulting from the amendment to 10 CFR 55 that eliminated the requirement for every licensed operator to pass an NRC-conducted requalification examination as a condition for license renewal. The supplement does not substantially alter either the initial or requalification examination processes and will become effective 30 days after its publication is noticed in the Federal Register. The corporate notification letters issued after the effective date will provide facility licensees with at least 90 days notice that the examinations will be administered in accordance with the revised procedures

  15. Emission- and product standards

    International Nuclear Information System (INIS)

    Jong, P. de

    1988-01-01

    This report makes part of a series of eight reports which have been drawn up in behalf of the dutch Policy Notition Radiation Standards (BNS). In this report the results are presented of an inventarization of the use of radioactive materials and ionizing-radiation emitting apparates in the Netherlands. Ch. 2 deals with the varous applications of radioactive materials in the Netherlands. Herein also the numbers and the various locations by application, and the amounts and character of the radioactive materials used, come under discussion. Besides, the various waste currents are considered separately. The use of ionizing-radiation emitting apparates is treated in ch. 3. In ch. 4 the differences and agreements of the various applications, concentrating on the emission and product standards to be drawn up, are entered further. Also on the base of these considerations, a number of starting points are formulated with regard to the way in which emission and product standards may be drawn up. Ch. 7 deals with the conclusions and indicates the most important hiates. (H.W.). 25 refs.; 5 figs.; 25 tabs

  16. Higgs results from ATLAS

    Directory of Open Access Journals (Sweden)

    Chen Xin

    2016-01-01

    Full Text Available The updated Higgs measurements in various search channels with ATLAS Run 1 data are reviewed. Both the Standard Model (SM Higgs results, such as H → γγ, ZZ, WW, ττ, μμ, bb̄, and Beyond Standard Model (BSM results, such as the charged Higgs, Higgs invisible decay and tensor couplings, are summarized. Prospects for future Higgs searches are briefly discussed.

  17. Higgs results from ATLAS

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00145153; The ATLAS collaboration

    2015-01-01

    The updated Higgs measurements in various search channels with ATLAS Run 1 data are reviewed. Both the Standard Model (SM) Higgs results, such as $H\\to\\gamma\\gamma,ZZ,WW,\\tau\\tau,\\mu\\mu,b\\bar{b}$, and Beyond Standard Model (BSM) results, such as the charged Higgs, Higgs invisible decay and tensor couplings, are summarized. Prospects for future Higgs searches are briefly discussed.

  18. Standardization and the European Standards Organisations

    Directory of Open Access Journals (Sweden)

    Marta Orviska

    2014-01-01

    Full Text Available Standardization is a relatively neglected aspect of the EU regulatory process and yet it is fundamental to that process and arguably has recently been the key vehicle in making the single market an economic reality. Yet the key standardization bodies in the EU, the ESOs, are scarcely known to the public and seldom discussed in the literature. In this article we redress this imbalance, arguing that standardization and integration are closely related concepts. We also argue that the ESOs have developed a degree of autonomy in expanding the boundaries of standardization and even in developing their own links with the rest of the world. Recent proposals put forward by the European Commission can be seen as an attempt to reduce that autonomy. These proposals emphasize the speed of, and stakeholder involvement in, standards production, which we further suggest are somewhat conflicting aims.

  19. Clinical quality standards for radiotherapy

    Science.gov (United States)

    2012-01-01

    Aim of the study The technological progress that is currently being witnessed in the areas of diagnostic imaging, treatment planning systems and therapeutic equipment has caused radiotherapy to become a high-tech and interdisciplinary domain involving staff of various backgrounds. This allows steady improvement in therapy results, but at the same time makes the diagnostic, imaging and therapeutic processes more complex and complicated, requiring every stage of those processes to be planned, organized, controlled and improved so as to assure high quality of services provided. The aim of this paper is to present clinical quality standards for radiotherapy as developed by the author. Material and methods In order to develop the quality standards, a comparative analysis was performed between European and Polish legal acts adopted in the period of 1980-2006 and the universal industrial ISO 9001:2008 standard, defining requirements for quality management systems, and relevant articles published in 1984-2009 were reviewed, including applicable guidelines and recommendations of American, international, European and Polish bodies, such as the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy & Oncology (ESTRO), the International Atomic Energy Agency (IAEA), and the Organisation of European Cancer Institutes (OECI) on quality assurance and management in radiotherapy. Results As a result, 352 quality standards for radiotherapy were developed and categorized into the following three groups: 1 – organizational standards; 2 – physico-technical standards and 3 – clinical standards. Conclusion Proposed clinical quality standards for radiotherapy can be used by any institution using ionizing radiation for medical purposes. However, standards are of value only if they are implemented, reviewed, audited and improved, and if there is a clear mechanism in place to monitor and address failure to meet agreed standards. PMID:23788854

  20. Standards for holdup measurement

    International Nuclear Information System (INIS)

    Zucker, M.S.

    1982-01-01

    Holdup measurement, needed for material balance, depend intensively on standards and on interpretation of the calibration procedure. More than other measurements, the calibration procedure using the standard becomes part of the standard. Standards practical for field use and calibration techniques have been developed. While accuracy in holdup measurements is comparatively poor, avoidance of bias is a necessary goal

  1. Designation of the European Working Group on Legionella Infection (EWGLI) amplified fragment length polymorphism types of Legionella pneumophila serogroup 1 and results of intercentre proficiency testing Using a standard protocol

    DEFF Research Database (Denmark)

    Fry, N K; Bangsborg, Jette Marie; Bergmans, A

    2002-01-01

    Infections (EWGLI) AFLP types, (ii). describes the EWGLI AFLP types identified for the 130 strains in the EWGLI culture collection, and (iii). reports the results of a newly introduced international programme of proficiency testing. Following preliminary analysis of 20 epidemiologically unrelated isolates...... (recorded as AFLP type 001-016 or untypeable) was determined by participants with reference to these 16 AFLP types, either visually or using gel analysis software where available, and reported to the coordinating centre. Nine of the 12 strains, including an epidemiologically related pair and two pairs...

  2. The Future of Geospatial Standards

    Science.gov (United States)

    Bermudez, L. E.; Simonis, I.

    2016-12-01

    The OGC is an international not-for-profit standards development organization (SDO) committed to making quality standards for the geospatial community. A community of more than 500 member organizations with more than 6,000 people registered at the OGC communication platform drives the development of standards that are freely available for anyone to use and to improve sharing of the world's geospatial data. OGC standards are applied in a variety of application domains including Environment, Defense and Intelligence, Smart Cities, Aviation, Disaster Management, Agriculture, Business Development and Decision Support, and Meteorology. Profiles help to apply information models to different communities, thus adapting to particular needs of that community while ensuring interoperability by using common base models and appropriate support services. Other standards address orthogonal aspects such as handling of Big Data, Crowd-sourced information, Geosemantics, or container for offline data usage. Like most SDOs, the OGC develops and maintains standards through a formal consensus process under the OGC Standards Program (OGC-SP) wherein requirements and use cases are discussed in forums generally open to the public (Domain Working Groups, or DWGs), and Standards Working Groups (SWGs) are established to create standards. However, OGC is unique among SDOs in that it also operates the OGC Interoperability Program (OGC-IP) to provide real-world testing of existing and proposed standards. The OGC-IP is considered the experimental playground, where new technologies are researched and developed in a user-driven process. Its goal is to prototype, test, demonstrate, and promote OGC Standards in a structured environment. Results from the OGC-IP often become requirements for new OGC standards or identify deficiencies in existing OGC standards that can be addressed. This presentation will provide an analysis of the work advanced in the OGC consortium including standards and testbeds

  3. Simplified propagation of standard uncertainties

    International Nuclear Information System (INIS)

    Shull, A.H.

    1997-01-01

    An essential part of any measurement control program is adequate knowledge of the uncertainties of the measurement system standards. Only with an estimate of the standards'' uncertainties can one determine if the standard is adequate for its intended use or can one calculate the total uncertainty of the measurement process. Purchased standards usually have estimates of uncertainty on their certificates. However, when standards are prepared and characterized by a laboratory, variance propagation is required to estimate the uncertainty of the standard. Traditional variance propagation typically involves tedious use of partial derivatives, unfriendly software and the availability of statistical expertise. As a result, the uncertainty of prepared standards is often not determined or determined incorrectly. For situations meeting stated assumptions, easier shortcut methods of estimation are now available which eliminate the need for partial derivatives and require only a spreadsheet or calculator. A system of simplifying the calculations by dividing into subgroups of absolute and relative uncertainties is utilized. These methods also incorporate the International Standards Organization (ISO) concepts for combining systematic and random uncertainties as published in their Guide to the Expression of Measurement Uncertainty. Details of the simplified methods and examples of their use are included in the paper

  4. Long term results of comparison of concurrent low-dose daily cisplatin versus the standard weekly cisplatin with six fractions per week radiotherapy in locally advanced head neck cancer

    Directory of Open Access Journals (Sweden)

    Pramod Kumar Gupta

    2016-01-01

    Full Text Available Aim and Objective: Weekly administration of cisplatin (cis-diamminedichloroplatinum [CDDP] appears more feasible and substantially more popular than the 3 weekly schedules due to better compliance. Different concurrent cisplatin schedules have been attempted including a daily schedule. We did a comparison of two consecutive single arm studies, i.e., use of weekly cisplatin versus daily cisplatin when used with concurrently with a moderately accelerated radiotherapy (RT schedule. Patients and Methods: Two prospective feasibility, safety and efficacy studies were carried out consecutively within the department. The weekly CDDP study was done from August 2003 to August 2005 and daily CDDP study was conducted from November 2005 to June 2007. Both studies included locally advanced stage III and IV squamous cell carcinoma of the head and neck region with RT dose of 70 Gy. Concurrent single-agent cisplatin was administered weekly (35 mg/m 2 in the first and daily (6 mg/m 2 in the second study. Results: Weekly cisplatin study had 68 and daily CDDP study had 52 patients. The median follow-up in the two studies was 93 and 63 months, respectively. Compliance in the two studies was comparable. Acute Grade III/IV mucositis and dysphagia were significantly higher in weekly cisplatin study. Late Grade II/III toxicities such as xerostomia, dysphagia, ototoxicity and nephrotoxicity were similar. The 5 years locoregional control was 18% and 25% and 5 years overall survival rate was 32% and 31% in weekly and daily cisplatin studies, respectively. Conclusions: Modest acceleration along with either "weekly" or "daily" cisplatin, whichever is possible in one′s setup, is do-able, provided due attention is paid to patient selection and supportive care.

  5. Drug-Coated Balloon vs Standard Percutaneous Transluminal Angioplasty for the Treatment of Atherosclerotic Lesions in the Superficial Femoral and Proximal Popliteal Arteries: One-Year Results of the MDT-2113 SFA Japan Randomized Trial.

    Science.gov (United States)

    Iida, Osamu; Soga, Yoshimitsu; Urasawa, Kazushi; Saito, Shigeru; Jaff, Michael R; Wang, Hong; Ookubo, Hiroko; Yokoi, Hiroyoshi

    2018-02-01

    To assess the safety and effectiveness of the MDT-2113 (IN.PACT Admiral) drug-coated balloon (DCB) for the treatment of de novo and native artery restenotic lesions in the superficial femoral and proximal popliteal arteries vs percutaneous transluminal angioplasty (PTA) with an uncoated balloon in a Japanese cohort. MDT-2113 SFA Japan ( ClinicalTrials.gov identifier NCT01947478) is an independently adjudicated, prospective, randomized, single-blinded trial that randomized (2:1) 100 patients (mean age 73.6±7.0 years; 76 men) from 11 Japanese centers to treatment with DCB (n=68) or PTA (n=32). Baseline characteristics were similar between the groups, including mean lesion length (9.15±5.85 and 8.89±6.01 cm for the DCB and PTA groups, respectively). The primary effectiveness outcome was primary patency at 12 months, defined as freedom from clinically-driven target lesion revascularization (CD-TLR) and freedom from restenosis as determined by duplex ultrasonography. The safety endpoint was a composite of 30-day device- and procedure-related death and target limb major amputation and clinically-driven target vessel revascularization within 12 months. Patients treated with DCBs exhibited superior 12-month primary patency (89%) compared to patients treated with PTA (48%, pSFA Japan trial showed superior treatment effect for DCB vs PTA, with excellent patency and low CD-TLR rates. These results are consistent with other IN.PACT SFA DCB trials and demonstrate the safety and effectiveness of this DCB for the treatment of femoropopliteal lesions in this Japanese cohort.

  6. Drug-coated balloon versus standard percutaneous transluminal angioplasty for the treatment of superficial femoral and popliteal peripheral artery disease: 12-month results from the IN.PACT SFA randomized trial.

    Science.gov (United States)

    Tepe, Gunnar; Laird, John; Schneider, Peter; Brodmann, Marianne; Krishnan, Prakash; Micari, Antonio; Metzger, Christopher; Scheinert, Dierk; Zeller, Thomas; Cohen, David J; Snead, David B; Alexander, Beaux; Landini, Mario; Jaff, Michael R

    2015-02-03

    Drug-coated balloons (DCBs) have shown promise in improving the outcomes for patients with peripheral artery disease. We compared a paclitaxel-coated balloon with percutaneous transluminal angioplasty (PTA) for the treatment of symptomatic superficial femoral and popliteal artery disease. The IN.PACT SFA Trial is a prospective, multicenter, single-blinded, randomized trial in which 331 patients with intermittent claudication or ischemic rest pain attributable to superficial femoral and popliteal peripheral artery disease were randomly assigned in a 2:1 ratio to treatment with DCB or PTA. The primary efficacy end point was primary patency, defined as freedom from restenosis or clinically driven target lesion revascularization at 12 months. Baseline characteristics were similar between the 2 groups. Mean lesion length and the percentage of total occlusions for the DCB and PTA arms were 8.94 ± 4.89 and 8.81 ± 5.12 cm (P=0.82) and 25.8% and 19.5% (P=0.22), respectively. DCB resulted in higher primary patency versus PTA (82.2% versus 52.4%; P<0.001). The rate of clinically driven target lesion revascularization was 2.4% in the DCB arm in comparison with 20.6% in the PTA arm (P<0.001). There was a low rate of vessel thrombosis in both arms (1.4% after DCB and 3.7% after PTA [P=0.10]). There were no device- or procedure-related deaths and no major amputations. In this prospective, multicenter, randomized trial, DCB was superior to PTA and had a favorable safety profile for the treatment of patients with symptomatic femoropopliteal peripheral artery disease. http://www.clinicaltrials.gov. Unique Identifiers: NCT01175850 and NCT01566461. © 2014 The Authors.

  7. Late Urinary Side Effects 10 Years After Low-Dose-Rate Prostate Brachytherapy: Population-Based Results From a Multiphysician Practice Treating With a Standardized Protocol and Uniform Dosimetric Goals

    Energy Technology Data Exchange (ETDEWEB)

    Keyes, Mira, E-mail: mkeyes@bccancer.bc.ca; Miller, Stacy; Pickles, Tom; Halperin, Ross; Kwan, Winkle; Lapointe, Vincent; McKenzie, Michael; Spadinger, Ingrid; Pai, Howard; Chan, Elisa K.; Morris, W. James

    2014-11-01

    Purpose: To determine late urinary toxicity (>12 months) in a large cohort of uniformly treated low-dose-rate prostate brachytherapy patients. Methods and Materials: From 1998 to 2009, 2709 patients with National Comprehensive Cancer Network–defined low-risk and low-tier intermediate-risk prostate cancer were treated with Iodine 125 ({sup 125}I) low-dose-rate prostate brachytherapy; 2011 patients with a minimum of 25 months of follow-up were included in the study. Baseline patients, treatment, implant factors, and late urinary toxicity (Radiation Therapy Oncology Group [RTOG] grading system and International Prostate Symptom Score [IPSS]) were recorded prospectively. Time to IPSS resolution, late RTOG genitourinary toxicity was examined with Kaplan-Meier and log-rank tests. Cox proportional hazards regression was done for individual covariates and multivariable models. Results: Median follow-up was 54.5 months (range, 2-13 years). Actuarial toxicity rates reached 27% and 10% (RTOG ≥2 and ≥3, respectively) at 9-13 years. Symptoms resolved quickly in the majority of patients (88% in 6-12 months). The prevalence of RTOG 0, 1, 2, 3, and 4 toxicity with a minimum of 7 years' follow-up was 70%, 21%, 6.4%, 2.3%, and 0.08%, respectively. Patients with a larger prostate volume, higher baseline IPSS, higher D90, acute toxicity, and age >70 years had more late RTOG ≥2 toxicity (all P≤.02). The IPSS resolved slower in patients with lower baseline IPSS and larger ultrasound prostate volume, those not receiving androgen deprivation therapy, and those with higher D90. The crude rate of RTOG 3 toxicity was 6%. Overall the rate of transurethral resection of the prostate was 1.9%; strictures, 2%; incontinence, 1.3%; severe symptoms, 1.8%; late catheterization, 1.3%; and hematuria, 0.8%. The majority (80%) resolved their symptoms in 6-12 months. Conclusion: Long-term urinary toxicity after brachytherapy is low. Although actuarial rates increase with longer

  8. Welfare standards in hospital mergers.

    Science.gov (United States)

    Katona, Katalin; Canoy, Marcel

    2013-08-01

    There is a broad literature on the consequences of applying different welfare standards in merger control. Total welfare is usually defined as the sum of consumer and provider surplus, i.e., potential external effects are not considered. The general result is then that consumer welfare is a more restrictive standard than total welfare, which is advantageous in certain situations. This relationship between the two standards is not necessarily true when the merger has significant external effects. We model mergers on hospital markets and allow for not-profit-maximizing behavior of providers and mandatory health insurance. Mandatory health insurance detaches the financial and consumption side of health care markets, and the concept consumer in merger control becomes non-evident. Patients not visiting the merging hospitals still are affected by price changes through their insurance premiums. External financial effects emerge on not directly affected consumers. We show that applying a restricted interpretation of consumer (neglecting externality) in health care merger control can reverse the relation between the two standards; consumer welfare standard can be weaker than total welfare. Consequently, applying the wrong standard can lead to both clearing socially undesirable and to blocking socially desirable mergers. The possible negative consequences of applying a simple consumer welfare standard in merger control can be even stronger when hospitals maximize quality and put less weight on financial considerations. We also investigate the implications of these results for the practice of merger control.

  9. Standards, Standards, Standards: The Unintended Consequences of Widening Participation?

    Science.gov (United States)

    Stuart, Mary

    2002-01-01

    Debate over widening access to higher education is narrowing to a focus on preservation of standards. Examination of the discourses of school policy, classroom environment, and peer culture shows how these competing cultures can work against efforts to increase participation. (Contains 17 references.) (SK)

  10. [Traceability of the standards and calibrations].

    Science.gov (United States)

    Vassault, A; Giroud, C; Arnaud, J

    2010-12-01

    Accuracy of results depends on the traceability of the standards values to a reference system. According to the ISO 15189 requirements, the laboratory has to document the traceability of the value of the standards used.

  11. Beyond the Standard Model

    Energy Technology Data Exchange (ETDEWEB)

    Lykken, Joseph D.; /Fermilab

    2010-05-01

    'BSM physics' is a phrase used in several ways. It can refer to physical phenomena established experimentally but not accommodated by the Standard Model, in particular dark matter and neutrino oscillations (technically also anything that has to do with gravity, since gravity is not part of the Standard Model). 'Beyond the Standard Model' can also refer to possible deeper explanations of phenomena that are accommodated by the Standard Model but only with ad hoc parameterizations, such as Yukawa couplings and the strong CP angle. More generally, BSM can be taken to refer to any possible extension of the Standard Model, whether or not the extension solves any particular set of puzzles left unresolved in the SM. In this general sense one sees reference to the BSM 'theory space' of all possible SM extensions, this being a parameter space of coupling constants for new interactions, new charges or other quantum numbers, and parameters describing possible new degrees of freedom or new symmetries. Despite decades of model-building it seems unlikely that we have mapped out most of, or even the most interesting parts of, this theory space. Indeed we do not even know what is the dimensionality of this parameter space, or what fraction of it is already ruled out by experiment. Since Nature is only implementing at most one point in this BSM theory space (at least in our neighborhood of space and time), it might seem an impossible task to map back from a finite number of experimental discoveries and measurements to a unique BSM explanation. Fortunately for theorists the inevitable limitations of experiments themselves, in terms of resolutions, rates, and energy scales, means that in practice there are only a finite number of BSM model 'equivalence classes' competing at any given time to explain any given set of results. BSM phenomenology is a two-way street: not only do experimental results test or constrain BSM models, they also suggest

  12. Standardization of biodosimetry operations

    International Nuclear Information System (INIS)

    Dainiak, Nicholas

    2016-01-01

    Methods and procedures for generating, interpreting and scoring the frequency of dicentric chromosomes vary among cytogenetic biodosimetry laboratories (CBLs). This variation adds to the already considerable lack of precision inherent in the dicentric chromosome assay (DCA). Although variability in sample collection, cell preparation, equipment and dicentric frequency scoring can never be eliminated with certainty, it can be substantially minimized, resulting in reduced scatter and improved precision. Use of standard operating procedures and technician exchange may help to mitigate variation. Although the development and adoption of international standards (ISO 21243 and ISO 19238) has helped to reduce variation in standard operating procedures (SOPs), all CBLs must maintain process improvement, and those with challenges may require additional assistance. Sources of variation that may not be readily apparent in the SOPs for sample collection and processing include variability in ambient laboratory conditions, media, serum lot and quantity and the use of particular combinations of cytokines. Variability in maintenance and calibration of metafer equipment, and in scoring criteria, reader proficiency and personal factors may need to be addressed. The calibration curve itself is a source of variation that requires control, using the same known-dose samples among CBLs, measurement of central tendency, and generation of common curves with periodic reassessment to detect drifts in dicentric yield. Finally, the dose estimate should be based on common scoring criteria, using of the z-statistic. Although theoretically possible, it is practically impossible to propagate uncertainty over the entire calibration curve due to the many factors contributing to variance. Periodic re-evaluation of the curve is needed by comparison with newly published curves (using statistical analysis of differences) and determining their potential causes. (author)

  13. APS beamline standard components handbook

    Energy Technology Data Exchange (ETDEWEB)

    Kuzay, T.M.

    1992-01-01

    It is clear that most Advanced Photon Source (APS) Collaborative Access Team (CAT) members would like to concentrate on designing specialized equipment related to their scientific programs rather than on routine or standard beamline components. Thus, an effort is in progress at the APS to identify standard and modular components of APS beamlines. Identifying standard components is a nontrivial task because these components should support diverse beamline objectives. To assist with this effort, the APS has obtained advice and help from a Beamline Standardization and Modularization Committee consisting of experts in beamline design, construction, and operation. The staff of the Experimental Facilities Division identified various components thought to be standard items for beamlines, regardless of the specific scientific objective of a particular beamline. A generic beamline layout formed the basis for this identification. This layout is based on a double-crystal monochromator as the first optical element, with the possibility of other elements to follow. Pre-engineering designs were then made of the identified standard components. The Beamline Standardization and Modularization Committee has reviewed these designs and provided very useful input regarding the specifications of these components. We realize that there will be other configurations that may require special or modified components. This Handbook in its current version (1.1) contains descriptions, specifications, and pre-engineering design drawings of these standard components. In the future, the APS plans to add engineering drawings of identified standard beamline components. Use of standard components should result in major cost reductions for CATs in the areas of beamline design and construction.

  14. APS beamline standard components handbook

    International Nuclear Information System (INIS)

    Kuzay, T.M.

    1992-01-01

    It is clear that most Advanced Photon Source (APS) Collaborative Access Team (CAT) members would like to concentrate on designing specialized equipment related to their scientific programs rather than on routine or standard beamline components. Thus, an effort is in progress at the APS to identify standard and modular components of APS beamlines. Identifying standard components is a nontrivial task because these components should support diverse beamline objectives. To assist with this effort, the APS has obtained advice and help from a Beamline Standardization and Modularization Committee consisting of experts in beamline design, construction, and operation. The staff of the Experimental Facilities Division identified various components thought to be standard items for beamlines, regardless of the specific scientific objective of a particular beamline. A generic beamline layout formed the basis for this identification. This layout is based on a double-crystal monochromator as the first optical element, with the possibility of other elements to follow. Pre-engineering designs were then made of the identified standard components. The Beamline Standardization and Modularization Committee has reviewed these designs and provided very useful input regarding the specifications of these components. We realize that there will be other configurations that may require special or modified components. This Handbook in its current version (1.1) contains descriptions, specifications, and pre-engineering design drawings of these standard components. In the future, the APS plans to add engineering drawings of identified standard beamline components. Use of standard components should result in major cost reductions for CATs in the areas of beamline design and construction

  15. Real-World Analysis of Dispensed IUs of Coagulation Factor IX and Resultant Expenditures in Hemophilia B Patients Receiving Standard Half-life Versus Extended Half-life Products and Those Switching from Standard Half-life to Extended Half-life Products.

    Science.gov (United States)

    Tortella, Bartholomew J; Alvir, José; McDonald, Margaret; Spurden, Dean; Fogarty, Patrick F; Chhabra, Amit; Pleil, Andreas M

    2018-01-24

    Hemophilia B requires replacement therapy with factor IX (FIX) coagulation products to treat and prevent bleeding episodes. A recently introduced extended half-life (EHL) recombinant FIX replacement product provided the opportunity to compare the amount of dispensed factor and expenditures for EHL treatment compared with a standard half-life (SHL) product. To determine factor international units (IUs) dispensed and expenditures associated with switching from nonacog alfa, the most commonly used SHL replacement product, to eftrenonacog alfa, an EHL FIX replacement product. Two U.S. claims databases were analyzed. A large national specialty pharmacy dispensation claims database was used to identify the number of IUs dispensed and monthly charges for all patients with hemophilia B from April 2015 to June 2016. Truven Health MarketScan Research Databases (January 2010-July 2016) were used to identify IUs and expenditures for patients with claims data for at least 3 months before and after switching from the SHL to the EHL product. Medians for IUs and expenditures are presented to accommodate for skewness of data distribution. The national specialty pharmacy database analysis included 296 patients with moderate or severe hemophilia B (233 on SHL; 94 on EHL). Median monthly factor dispensed was 11% lower (2,142 IU) in the EHL versus SHL cohort over the study period, while individual monthly reductions ranged from 32% to 47% (9,838 IU to 16,514 IU). Using the wholesale acquisition cost, the median per-patient monthly factor expenditures over the 15-month study period were 94% higher ($23,005) for the EHL than for the SHL product. Individual median monthly expenditure differences ranged from 15% ($6,562) to 49% ($19,624). In the Truven database, 14 patients switched from the SHL to the EHL product. The amount of factor dispensed was variable; in the 1-year period before and after the switch from the SHL to the EHL product, mean IUs dispensed decreased by 3,005 IU, while

  16. Agent Standards Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation of the work herein proposed is the development of standards for software autonomous agents. These standards are essential to achieve software...

  17. BTS statistical standards manual

    Science.gov (United States)

    2005-10-01

    The Bureau of Transportation Statistics (BTS), like other federal statistical agencies, establishes professional standards to guide the methods and procedures for the collection, processing, storage, and presentation of statistical data. Standards an...

  18. Dental Assisting Program Standards.

    Science.gov (United States)

    Georgia Univ., Athens. Dept. of Vocational Education.

    This publication contains statewide standards for the dental assisting program in Georgia. The standards are divided into 12 categories: foundations (philosophy, purpose, goals, program objectives, availability, evaluation); admissions (admission requirements, provisional admission requirements, recruitment, evaluation and planning); program…

  19. The Distance Standard Deviation

    OpenAIRE

    Edelmann, Dominic; Richards, Donald; Vogel, Daniel

    2017-01-01

    The distance standard deviation, which arises in distance correlation analysis of multivariate data, is studied as a measure of spread. New representations for the distance standard deviation are obtained in terms of Gini's mean difference and in terms of the moments of spacings of order statistics. Inequalities for the distance variance are derived, proving that the distance standard deviation is bounded above by the classical standard deviation and by Gini's mean difference. Further, it is ...

  20. Delta-tilde interpretation of standard linear mixed model results

    DEFF Research Database (Denmark)

    Brockhoff, Per Bruun; Amorim, Isabel de Sousa; Kuznetsova, Alexandra

    2016-01-01

    data set and compared to actual d-prime calculations based on Thurstonian regression modeling through the ordinal package. For more challenging cases we offer a generic "plug-in" implementation of a version of the method as part of the R-package SensMixed. We discuss and clarify the bias mechanisms...

  1. Quality of semantic standards

    NARCIS (Netherlands)

    Folmer, E.J.A.

    2012-01-01

    Little scientific literature addresses the issue of quality of semantic standards, albeit a problem with high economic and social impact. Our problem survey, including 34 semantic Standard Setting Organizations (SSOs), gives evidence that quality of standards can be improved, but for improvement a

  2. Automotive Technology Skill Standards

    Science.gov (United States)

    Garrett, Tom; Asay, Don; Evans, Richard; Barbie, Bill; Herdener, John; Teague, Todd; Allen, Scott; Benshoof, James

    2009-01-01

    The standards in this document are for Automotive Technology programs and are designed to clearly state what the student should know and be able to do upon completion of an advanced high-school automotive program. Minimally, the student will complete a three-year program to achieve all standards. Although these exit-level standards are designed…

  3. [Ophthalmology and standardization].

    Science.gov (United States)

    Heitz, R

    1989-01-01

    The standards are the references for quality and safety of materials, instruments and devices in ophtalmological use. The French standardisation association, "Association Française de Normalisation" (AFNOR), drafts his standards in connection with the concerned professionals. The ophthalmologists are concerned by standards of diagnostic and therapeutic instruments, intraocular and orbital implants, contact lenses, spectacle frames and glasses, and ocular protectors.

  4. Comparative Advantage, Trade and Labour Standards

    OpenAIRE

    Matthias Busse

    2002-01-01

    This paper empirically explores the relationship between labour standards and comparative advantage. Focusing on unskilled-labour-intensive goods and core labour standards, the results show that the effects of low standards depend on the type of standard: Weaker basic union rights are associated with a stronger comparative advantage. Forced and child labour also lead to an increase in the endowment of unskilled labour, and hence improve comparative advantage in unskilled-labour-intensive good...

  5. Beyond the standard model

    International Nuclear Information System (INIS)

    Wilczek, F.

    1993-01-01

    The standard model of particle physics is highly successful, although it is obviously not a complete or final theory. In this presentation the author argues that the structure of the standard model gives some quite concrete, compelling hints regarding what lies beyond. Essentially, this presentation is a record of the author's own judgement of what the central clues for physics beyond the standard model are, and also it is an attempt at some pedagogy. 14 refs., 6 figs

  6. Standard Model processes

    CERN Document Server

    Mangano, M.L.; Aguilar-Saavedra, Juan Antonio; Alekhin, S.; Badger, S.; Bauer, C.W.; Becher, T.; Bertone, V.; Bonvini, M.; Boselli, S.; Bothmann, E.; Boughezal, R.; Cacciari, M.; Carloni Calame, C.M.; Caola, F.; Campbell, J.M.; Carrazza, S.; Chiesa, M.; Cieri, L.; Cimaglia, F.; Febres Cordero, F.; Ferrarese, P.; D'Enterria, D.; Ferrera, G.; Garcia i Tormo, X.; Garzelli, M.V.; Germann, E.; Hirschi, V.; Han, T.; Ita, H.; Jäger, B.; Kallweit, S.; Karlberg, A.; Kuttimalai, S.; Krauss, F.; Larkoski, A.J.; Lindert, J.; Luisoni, G.; Maierhöfer, P.; Mattelaer, O.; Martinez, H.; Moch, S.; Montagna, G.; Moretti, M.; Nason, P.; Nicrosini, O.; Oleari, C.; Pagani, D.; Papaefstathiou, A.; Petriello, F.; Piccinini, F.; Pierini, M.; Pierog, T.; Pozzorini, S.; Re, E.; Robens, T.; Rojo, J.; Ruiz, R.; Sakurai, K.; Salam, G.P.; Salfelder, L.; Schönherr, M.; Schulze, M.; Schumann, S.; Selvaggi, M.; Shivaji, A.; Siodmok, A.; Skands, P.; Torrielli, P.; Tramontano, F.; Tsinikos, I.; Tweedie, B.; Vicini, A.; Westhoff, S.; Zaro, M.; Zeppenfeld, D.; CERN. Geneva. ATS Department

    2017-06-22

    This report summarises the properties of Standard Model processes at the 100 TeV pp collider. We document the production rates and typical distributions for a number of benchmark Standard Model processes, and discuss new dynamical phenomena arising at the highest energies available at this collider. We discuss the intrinsic physics interest in the measurement of these Standard Model processes, as well as their role as backgrounds for New Physics searches.

  7. Governing through standards

    DEFF Research Database (Denmark)

    Brøgger, Katja

    This abstract adresses the ways in which new education standards have become integral to new modes of education governance. The paper explores the role of standards for accelerating the shift from national to transnational governance in higher education. Drawing on the case of higher education...... development in Scandinavia, the paper focuses on the unintended effects of the new international standards. The Bologna process was reframed and recontextualized in ways that undermined the very system it was set out to transform and govern....

  8. The Standard Model course

    CERN Multimedia

    CERN. Geneva HR-RFA

    2006-01-01

    Suggested Readings: Aspects of Quantum Chromodynamics/A Pich, arXiv:hep-ph/0001118. - The Standard Model of Electroweak Interactions/A Pich, arXiv:hep-ph/0502010. - The Standard Model of Particle Physics/A Pich The Standard Model of Elementary Particle Physics will be described. A detailed discussion of the particle content, structure and symmetries of the theory will be given, together with an overview of the most important experimental facts which have established this theoretical framework as the Standard Theory of particle interactions.

  9. International hearing protector standardization

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2002-01-01

    Hearing protectors shall fulfill some minimum requirements to their performance. As hearing protector manufacturers sell the products all over the world, the testing and certification of hearing protectors has become an international issue. The ISO working group WG17 under the headlines Acoustics......, Noise, produce hearing protector standards to be used at an international level. The presentation will cover the ongoing work in WG17, including the revision of existing standards (ISO 4869-1, ISO 4869-3), upcoming new standards (ISO 4869-7) and the plans and status for future standards (performance...

  10. Standard NIM instrumentation system

    CERN Document Server

    1990-01-01

    NIM is a standard modular instrumentation system that is in wide use throughout the world. As the NIM system developed and accommodations were made to a dynamic instrumentation field and a rapidly advancing technology, additions, revisions and clarifications were made. These were incorporated into the standard in the form of addenda and errata. This standard is a revision of the NIM document, AEC Report TID- 20893 (Rev 4) dated July 1974. It includes all the addenda and errata items that were previously issued as well as numerous additional items to make the standard current with modern technology and manufacturing practice.

  11. How AASL Learning Standards Inform ACRL Information Literacy Standards

    Science.gov (United States)

    Farmer, Lesley S. J.

    2013-01-01

    ACRL and other academic librarians are currently re-examining the tough questions of learning, literacy, and education--and the librarians' role in addressing these issues. They can use AASL's learning standards as one springboard for thought, particularly in terms of articulating learning. The result is a developmentally appropriate set of…

  12. Position paper on standardization

    International Nuclear Information System (INIS)

    1991-04-01

    The ''NPOC Strategic Plan for Building New Nuclear Plants'' creates a framework within which new standardized nuclear plants may be built. The Strategic Plan is an expression of the nuclear energy industry's serious intent to create the necessary conditions for new plant construction and operation. One of the key elements of the Strategic Plan is a comprehensive industry commitment to standardization: through design certification, combined license, first-of-a-kind engineering, construction, operation and maintenance of nuclear power plants. The NPOC plan proposes four stages of standardization in advanced light water reactors (ALWRs). The first stage is established by the ALWR Utility Requirements Document which specifies owner/operator requirements at a functional level covering all elements of plant design and construction, and many aspects of operations and maintenance. The second stage of standardization is that achieved in the NRC design certification. This certification level includes requirements, design criteria and bases, functional descriptions and performance requirements for systems to assure plant safety. The third stage of standardization, commercial standardization, carries the design to a level of completion beyond that required for design certification to enable the industry to achieve potential increases in efficiency and economy. The final stage of standardization is enhanced standardization beyond design. A standardized approach is being developed in construction practices, operating, maintenance training, and procurement practices. This comprehensive standardization program enables the NRC to proceed with design certification with the confidence that standardization beyond the regulations will be achieved. This confidence should answer the question of design detail required for design certification, and demonstrate that the NRC should require no further regulatory review beyond that required by 10 CFR Part 52

  13. High-pressure phase relations in the composition of albite NaAlSi3O8 constrained by an ab initio and quasi-harmonic Debye model, and their implications

    Science.gov (United States)

    Deng, L.; Liu, X.; Liu, H.; Dong, J.

    2010-12-01

    The high pressure physical-chemical behaviors of feldspar in subducted slab are very important to the geodynamic process in the deep interior of the Earth. Albite (NaAlSi3O8;Ab) is one of the few end members in the feldspar family, and its high-P behavior is obviously a prerequisite to the full understanding of the physical-chemical properties of feldspar at high pressures. So far it has been well accepted that Ab breaks down to the phase assemblage of Jadeite+Stishovite(NaAlSi2O6; Jd, SiO2; St,JS hereafter) at ~9-10 GPa. The JS phase assemblage might be stable up to ~23 GPa, and eventually directly change into the phase assemblage of calcium-ferrite type NaAlSiO4 (Cf) +2St (CS hereafter). However, some independent researches suggest there is an intermediate phase Na-hollandite (Na-Hall; a phase with the composition of NaAlSi3O8 and the structure of hollandite) between JS phase assemblage transition into CS phase assemblage (Liu 1978; Tutti 2007; Sekine and Ahrens, 1992; Beck et al., 2004). Whether Na-Hall is a thermodynamic stable phase under high P-T conditions remains unknown. In this work, phase relations in the composition of albite NaAlSi3O8 at pressures up to 40 GPa were constrained by a theoretical method that combines the ab initio calculation and quasi-harmonic Debyemodel. First, the P-T dependence of the thermodynamic potentials of the individual phase, St, Cf, Jd and the hypothetical Na-Holl were derived. Our results are generally in consistent agreement with available experimental data and previous theoretical predictions. Second, the Gibbs free energy of the hypothetical Na-Holl phase was compared with that of the phase assemblages JS and CS. Our results show that the Na-Holl phase is not a thermodynamically stable phase over the studied P-T conditions of 0-40 GPa and 100-600 K, which rules it out as a possible intermediate phase along the transition path from the JS phase assemblage to CS phase assemblage. Our calculations have predicted that the JS

  14. 77 FR 43542 - Cost Accounting Standards: Cost Accounting Standards 412 and 413-Cost Accounting Standards...

    Science.gov (United States)

    2012-07-25

    ... Accounting Standards: Cost Accounting Standards 412 and 413--Cost Accounting Standards Pension Harmonization Rule AGENCY: Cost Accounting Standards Board, Office of Federal Procurement Policy, Office of... Policy (OFPP), Cost Accounting Standards Board (Board), is publishing technical corrections to the final...

  15. State Skill Standards: Photography

    Science.gov (United States)

    Howell, Frederick; Reed, Loretta; Jensen, Capra; Robison, Gary; Taylor, Susan; Pavesich, Christine

    2007-01-01

    The Department of Education has undertaken an ambitious effort to develop statewide skill standards for all content areas in career and technical education. The standards in this document are for photography programs and are designed to clearly state what the student should know and be able to do upon completion of an advanced high-school program.…

  16. Standards and Administration.

    Science.gov (United States)

    Gross, S. P.

    1978-01-01

    Presents a literature review of water quality standards and administration, covering publications of 1976-77. Consideration is given to municipal facilities, National Pollutant Discharge Elimination Systems, regional and international water quality management, and effluent standards. A list of 99 references is also presented. (HM)

  17. How many standards?

    DEFF Research Database (Denmark)

    Maegaard, Marie

    2009-01-01

    Discussions of standardisation and standard languages has a long history in linguistics. Tore Kristiansen has contributed to these discussions in various ways, and in this chapter I will focus on his claim that young Danes operate with two standards, one for the media and one for the school...

  18. Standard Weights and Measures

    Indian Academy of Sciences (India)

    The mass standard, represented by the proto- type kilogram, is the only remaining artifact, but there are promising proposals to replace that in the near future. Ever since humans started living in community settle- ments, day to day activities have required the adoption of a set of standards for weights and measures. For ex-.

  19. Revisiting Professional Teacher Standards

    Science.gov (United States)

    Watson, Amanda

    2016-01-01

    The Australian Society for Music Education's (ASME) involvement in the development of professional standards for music educators was a significant and active research time in the history of the Society. As ASME celebrates its golden jubilee, it is appropriate to revisit that history and consider the future prospects of subject-specific standards.…

  20. Weston Standard battery

    CERN Multimedia

    This is a Weston AOIP standard battery with its calibration certificate (1956). Inside, the glassware forms an "H". Its name comes from the British physicist Edward Weston. A standard is the materialization of a given quantity whose value is known with great accuracy.

  1. Standardization or Stigmatization? Challenges Confronting ...

    African Journals Online (AJOL)

    Abstract: The article investigates the effects of the underutilization of the abundant vocabulary of Sesotho sa Leboa, which results from a one-sided standardization approach owing to the disregard and stigmatization of most dialects. Sesotho sa Leboa has several dialects differing greatly concerning terminology ...

  2. Standardization or Stigmatization? Challenges Confronting ...

    African Journals Online (AJOL)

    rbr

    of Sesotho sa Leboa, which results from a one-sided standardization approach owing to the dis- .... activity. These missionaries started developing orthographies in Sepedi and Seko- pa, and translating the Bible and many religious publications into these dia- lects. ..... size of the lexicon of Sesotho sa Leboa extensively.

  3. Standard Model at LHC 2016

    CERN Document Server

    2016-01-01

    The meeting aims to bring together experimentalists and theorists to discuss the phenomenology, observational results and theoretical tools for Standard Model physics at the LHC. The agenda is divided into four working groups: Electroweak physics Higgs physics QCD (hard, soft & PDFs) Top & flavour physics

  4. A case of standardization?

    DEFF Research Database (Denmark)

    Rod, Morten Hulvej; Høybye, Mette Terp

    2016-01-01

    Guidelines are increasingly used in an effort to standardize and systematize health practices at the local level and to promote evidence-based practice. The implementation of guidelines frequently faces problems, however, and standardization processes may in general have other outcomes than...... the ones envisioned by the makers of standards. In 2012, the Danish National Health Authorities introduced a set of health promotion guidelines that were meant to guide the decision making and priority setting of Denmark's 98 local governments. The guidelines provided recommendations for health promotion...... and standardization. It remains an open question whether or not the guidelines lead to more standardized policies and interventions, but we suggest that the guidelines promote a risk factor-oriented approach as the dominant frame for knowledge, reasoning, decision making and priority setting in health promotion. We...

  5. Evaluating Living Standard Indicators

    Directory of Open Access Journals (Sweden)

    Birčiaková Naďa

    2015-09-01

    Full Text Available This paper deals with the evaluation of selected available indicators of living standards, divided into three groups, namely economic, environmental, and social. We have selected six countries of the European Union for analysis: Bulgaria, the Czech Republic, Hungary, Luxembourg, France, and Great Britain. The aim of this paper is to evaluate indicators measuring living standards and suggest the most important factors which should be included in the final measurement. We have tried to determine what factors influence each indicator and what factors affect living standards. We have chosen regression analysis as our main method. From the study of factors, we can deduce their impact on living standards, and thus the value of indicators of living standards. Indicators with a high degree of reliability include the following factors: size and density of population, health care and spending on education. Emissions of carbon dioxide in the atmosphere also have a certain lower degree of reliability.

  6. Survey of standards for electronic image displays

    Science.gov (United States)

    Rowe, William A.

    1996-02-01

    Electronic visual displays have been evolving from the 1960's basis of cathode ray tube (CRT) technology. Now, many other technologies are also available, including both flat panels and projection displays. Standards for these displays are being developed at both the national level and the international levels. Standards activity within the United States is in its infancy and is fragmented according to the inclination of each of the standards developing organizations. The latest round of flat panel display technology was primarily developed in Japan. Initially standards arose from component vendor-to-OEM customer relationships. As a result, Japanese standards for components are the best developed. The Electronics Industries Association of Japan (EIAJ) is providing their standards to the International Electrotechnical Commission (IEC) for adoption. On the international level, professional societies such as the human factors society (hfs) and the International Organization for Standardization (ISO) have completed major standards, hfs developed the first ergonomic standard hfs-100 and the ISO has developed some sections of a broader ergonomic standard ISO 9241. This paper addresses the organization of standards activity. Active organizations and their areas of focus are identified. The major standards that have been completed or are in development are described. Finally, suggestions for improving the this standards activity are proposed.

  7. Recent results from LEP

    Indian Academy of Sciences (India)

    Recent results from the LEP collider at CERN are presented: on the identification of +- → +- and the determination of the mass and width and limits on its anomalous couplings; the search for the Standard Model and non-minimal Higgs; search for SUSY and other new particles. Fits to all electroweak data leading to ...

  8. First AFP results

    CERN Document Server

    Staszewski, Rafal; The ATLAS collaboration

    2017-01-01

    ATLAS Forward Proton (AFP) are detectors dedicated to measurements of protons scattered diffractively or electromagnetically at small angles in inelastic processes. The first arm of AFP was installed in 2016. The installation of the full system was finished in 2017. Since 2016 AFP has collected data is special and standard runs. The presentation shows the first results obtained with data collected by AFP.

  9. Enceladus Results

    Data.gov (United States)

    National Aeronautics and Space Administration — Here are some results from the Spectra Decomposition Algorithm on infrared spectral images of Saturn's moon Enceladus. Figure 1 is the spatial contribution of the...

  10. 1998 results

    International Nuclear Information System (INIS)

    Gadonneix, P.

    1998-01-01

    This document presents the financial and commercial results of Gaz de France (GdF) company for 1998. The following points are presented successively: financial results (budget results, turnover, self-financing capacity, investments, debt situation), commercial results (some remarkable numbers and records, the tertiary and residential market, the industrial market, cogeneration and natural gas for vehicles), the strategy, 1998 realizations and perspectives (the natural gas energy in the 21. century, the development of GdF, the gas distribution and services (development of the French distribution system, export of the know-how, development of services), the transportation and storage systems threw Europe (densification of the pipeline network, the key-position of France, the north-south equilibrium of the distribution network), the natural gas production by GdF, the diversification of supplies, and the main daughter companies abroad). (J.S.)

  11. Rough Standard Neutrosophic Sets: An Application on Standard Neutrosophic Information Systems

    Directory of Open Access Journals (Sweden)

    Nguyen Xuan Thao

    2016-12-01

    Full Text Available A rough fuzzy set is the result of the approximation of a fuzzy set with respect to a crisp approximation space. It is a mathematical tool for the knowledge discovery in the fuzzy information systems. In this paper, we introduce the concepts of rough standard neutrosophic sets and standard neutrosophic information system, and give some results of the knowledge discovery on standard neutrosophic information system based on rough standard neutrosophic sets.

  12. The standard model and beyond

    CERN Document Server

    Langacker, Paul

    2017-01-01

    This new edition of The Standard Model and Beyond presents an advanced introduction to the physics and formalism of the standard model and other non-abelian gauge theories. It provides a solid background for understanding supersymmetry, string theory, extra dimensions, dynamical symmetry breaking, and cosmology. In addition to updating all of the experimental and phenomenological results from the first edition, it contains a new chapter on collider physics; expanded discussions of Higgs, neutrino, and dark matter physics; and many new problems. The book first reviews calculational techniques in field theory and the status of quantum electrodynamics. It then focuses on global and local symmetries and the construction of non-abelian gauge theories. The structure and tests of quantum chromodynamics, collider physics, the electroweak interactions and theory, and the physics of neutrino mass and mixing are thoroughly explored. The final chapter discusses the motivations for extending the standard model and examin...

  13. Research Results

    Science.gov (United States)

    2011-12-01

    Research on Global Carbon Emission and Sequestration NSFC Funded Project Made Significant Progress in Quantum Dynamics Functional Human Blood Protein Obtained from Rice How Giant Pandas Thrive on a Bamboo Diet New Evidence of Interpersonal Violence from 129,000 Years Ago Found in China Aptamer-Mediated Efficient Capture and Release of T Lymphocytes on Nanostructured Surfaces BGI Study Results on Resequencing 50 Accessions of Rice Cast New Light on Molecular Breeding BGI Reports Study Results on Frequent Mutation of Genes Encoding UMPP Components in Kidney Cancer Research on Habitat Shift Promoting Species Diversification

  14. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1993-01-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining licensees and applicants for reactor operator and senior reactor operator licenses at power reactor facilities pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). The Examiner Standards are intended to assist NRC examiners and facility licensees to better understand the initial and requalification examination processes and to ensure the equitable and consistent administration of examinations to all applicants. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator licensing policy changes

  15. Wireless installation standard

    International Nuclear Information System (INIS)

    Lim, Hwang Bin

    2007-12-01

    This is divided six parts which are radio regulation law on securing of radio resource, use of radio resource, protection of radio resource, radio regulation enforcement ordinance with securing, distribution and assignment of radio regulation, radio regulation enforcement regulation on utility of radio resource and technical qualification examination, a wireless installation regulation of technique standard and safety facility standard, radio regulation such as certification regulation of information communicative machines and regulation of radio station on compliance of signal security, radio equipment in radio station, standard frequency station and emergency communication.

  16. Tensor force and debye screening in quarkonium-type mesons

    International Nuclear Information System (INIS)

    Kovacs, L.B.; Kovacs, T.G.; Lovas, I.

    1990-01-01

    We use a non-relativistic quantum-mechanical model to investigate the effect of a screening plasma on two quarkonium-type mesons: the charmonium and bottonium. The stability of these mesons in the plasma is estimated in two cases: including the tensor and spin-orbit term in the potential and without these terms. It turns out that while the bottonium is somewhat stabilized by the tensor force, the charmonium becomes less stabil due to this modification of the potential. Thus the charmonium seems to be a more sensitive probe of the quark-gluon plasma formation than it was thought to be without including the tensor force. (Authors)

  17. Terahertz reflection spectroscopy of Debye relaxation in polar liquids

    DEFF Research Database (Denmark)

    Møller, Uffe; Cooke, David; Tanaka, Koichiro

    2009-01-01

    Terahertz (THz) radiation interacts strongly with the intermolecular hydrogen-bond network in aqueous liquids. The dielectric properties of liquid water and aqueous solutions in the THz spectral region are closely linked to the microscopic dynamics of the liquid solution, and hence THz spectroscopy...... for remote detection of some of the properties of bottled liquids. Here we present a review of THz spectroscopy and modeling of water-ethanol mixtures, and establish a link between the dielectric function of water-ethanol mixtures and some of their thermodynamic properties. We then review how the knowledge...... offers an important insight into fundamental intermolecular interactions in polar liquids. At the same time, the strong and characteristic interaction between THz radiation and liquids offers a methodology for the classification of liquids inside containers, and hence the THz region is suitable...

  18. Debye temperatures of uranium chalcogenides from their lattice ...

    Indian Academy of Sciences (India)

    Unknown

    Chalcogenides (UX,. X = S, Se, Te) show ferromagnetic ordering while the pnictides (UY, Y = N, P, As, Sb, Bi) order antiferromag- netically. Their lattice vibrational properties have been extensively studied. At the same time, UPt3 and UBe13 have gained significance in another way. They belong to the heavy fermion system.

  19. Elastic and piezoelectric properties, sound velocity and Debye ...

    Indian Academy of Sciences (India)

    Algeria. ∗. Corresponding author. E-mail: salah_daoud07@yahoo.fr. MS received 17 January 2013; revised 29 April 2013; accepted 4 July 2013. DOI: 10.1007/s12043-013-0596-2; ePublication: 27 October 2013. Abstract. Pseudopotential plane-wave method (PP–PW) based on density functional theory. (DFT) and density ...

  20. Institutional model for supporting standardization

    International Nuclear Information System (INIS)

    Sanford, M.O.; Jackson, K.J.

    1993-01-01

    Restoring the nuclear option for utilities requires standardized designs. This premise is widely accepted by all parties involved in ALWR development activities. Achieving and maintaining standardization, however, demands new perspectives on the roles and responsibilities for the various commercial organizations involved in nuclear power. Some efforts are needed to define a workable model for a long-term support structure that will allow the benefits of standardization to be realized. The Nuclear Power Oversight Committee (NPOC) has developed a strategic plan that lays out the steps necessary to enable the nuclear industry to be in a position to order a new nuclear power plant by the mid 1990's. One of the key elements of the plan is the, ''industry commitment to standardization: through design certification, combined license, first-of-a-kind engineering, construction, operation, and maintenance of nuclear power plants.'' This commitment is a result of the recognition by utilities of the substantial advantages to standardization. Among these are economic benefits, licensing benefits from being treated as one of a family, sharing risks across a broader ownership group, sharing operating experiences, enhancing public safety, and a more coherent market force. Utilities controlled the construction of the past generation of nuclear units in a largely autonomous fashion procuring equipment and designs from a vendor, engineering services from an architect/engineer, and construction from a construction management firm. This, in addition to forcing the utility to assume virtually all of the risks associated with the project, typically resulted in highly customized designs based on preferences of the individual utility. However, the benefits of standardization can be realized only through cooperative choices and decision making by the utilities and through working as partners with reactor vendors, architect/engineers, and construction firms

  1. SOFG: Standards requirements

    International Nuclear Information System (INIS)

    Gerganov, T.; Grigorov, S.; Kozhukharov, V.; Brashkova, N.

    2005-01-01

    It is well-known that Solid Oxide Fuel Cells will have industrial application in the nearest future. In this context, the problem of SOFC materials and SOFC systems standardization is of high level of priority. In the present study the attention is focused on the methods for physical and chemical characterization of the materials for SOFC components fabrication and about requirements on single SOFC cells tests. The status of the CEN, ISO, ASTM (ANSI, ASSN) and JIS class of standards has been verified. Standards regarding the test methods for physical-chemical characterization of vitreous materials (as sealing SOFC component), ceramic materials (as electrodes and electrolyte components, including alternative materials used) and metallic materials (interconnect components) are subject of overview. It is established that electrical, mechanical, surface and interfacial phenomena, chemical durability and thermal corrosion behaviour are the key areas for standardization of the materials for SOFC components

  2. Scrutinising safety standards

    Energy Technology Data Exchange (ETDEWEB)

    Pietersen, C.M. [Safety Service Center BV (Netherlands)

    2001-01-01

    Until the introduction of the International Electrotechnical Commission's standard IEC 61508, there was no provision for relating risks to people and the environment, to the risks of financial loss. Although IEC 61508 fills most of the gaps in the process industry, there are still some loopholes. Four points covered by the standard are listed. It is expected that the standard will lead to an optimum cost-benefit situation with 'fit-for-purpose' safety and minimum nuisance shutdowns, or process plant disturbances. It should give clear guidance on 'how safe is safe enough.' IEC 61508 can be implemented through various routes. Insurance companies and regulators are starting to require implementation of the new standard. Five points which need to be ascertained for implementation are listed and diagrams illustrate the IEC 61508 safety lifecycle and the risk-reduction requirements.

  3. STELLA Standards Framework.

    Science.gov (United States)

    English in Australia, 2001

    2001-01-01

    Presents a provisional framework for the STELLA (Standards for Teachers of English Language and Literacy in Australia), which identifies broad dimensions of teaching together with groupings of related attributes derived from teachers' narratives. (RS)

  4. Ozone Standard Reference Photometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Standard Reference Photometer (SRP) Program began in the early 1980s as collaboration between NIST and the U.S. Environmental Protection Agency (EPA) to design,...

  5. National Pesticide Standard Repository

    Science.gov (United States)

    EPA's National Pesticide Standards Repository collects and maintains an inventory of analytical “standards” of registered pesticides in the United States, as well as some that are not currently registered for food and product testing and monitoring.

  6. Beyond the standard model

    International Nuclear Information System (INIS)

    Gaillard, M.K.

    1990-04-01

    The unresolved issues of the standard model are reviewed, with emphasis on the gauge hierarchy problem. A possible mechanism for generating a hierarchy in the context of superstring theory is described. 24 refs

  7. Standardization in synthetic biology.

    Science.gov (United States)

    Müller, Kristian M; Arndt, Katja M

    2012-01-01

    Synthetic Biology is founded on the idea that complex biological systems are built most effectively when the task is divided in abstracted layers and all required components are readily available and well-described. This requires interdisciplinary collaboration at several levels and a common understanding of the functioning of each component. Standardization of the physical composition and the description of each part is required as well as a controlled vocabulary to aid design and ensure interoperability. Here, we describe standardization initiatives from several disciplines, which can contribute to Synthetic Biology. We provide examples of the concerted standardization efforts of the BioBricks Foundation comprising the request for comments (RFC) and the Registry of Standardized Biological parts as well as the international Genetically Engineered Machine (iGEM) competition.

  8. AKRO: Standard Prices

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Standard prices are generated for cost recovery programs in the Individual Fishing Quota (IFQ) halibut and sablefish, BSAI Rationalized crab, and Central Gulf of...

  9. Fiber optics standard dictionary

    CERN Document Server

    Weik, Martin H

    1997-01-01

    Fiber Optics Vocabulary Development In 1979, the National Communications System published Technical InfonnationBulle­ tin TB 79-1, Vocabulary for Fiber Optics and Lightwave Communications, written by this author. Based on a draft prepared by this author, the National Communications System published Federal Standard FED-STD-1037, Glossary of Telecommunications Terms, in 1980 with no fiber optics tenns. In 1981, the first edition of this dictionary was published under the title Fiber Optics and Lightwave Communications Standard Dictionary. In 1982, the then National Bureau of Standards, now the National Institute of Standards and Technology, published NBS Handbook 140, Optical Waveguide Communications Glossary, which was also published by the General Services Admin­ istration as PB82-166257 under the same title. Also in 1982, Dynamic Systems, Inc. , Fiberoptic Sensor Technology Handbook, co-authored and edited by published the this author, with an extensive Fiberoptic Sensors Glossary. In 1989, the handbook w...

  10. FDA Recognized Consensus Standards

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database consists of those national and international standards recognized by FDA which manufacturers can declare conformity to and is part of the information...

  11. 1996 DOE technical standards program workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    The workshop theme is `The Strategic Standardization Initiative - A Technology Exchange and Global Competitiveness Challenge for DOE.` The workshop goal is to inform the DOE technical standards community of strategic standardization activities taking place in the Department, other Government agencies, standards developing organizations, and industry. Individuals working on technical standards will be challenged to improve cooperation and communications with the involved organizations in response to the initiative. Workshop sessions include presentations by representatives from various Government agencies that focus on coordination among and participation of Government personnel in the voluntary standards process; reports by standards organizations, industry, and DOE representatives on current technology exchange programs; and how the road ahead appears for `information superhighway` standardization. Another session highlights successful standardization case studies selected from several sites across the DOE complex. The workshop concludes with a panel discussion on the goals and objectives of the DOE Technical Standards Program as envisioned by senior DOE management. The annual workshop on technical standards has proven to be an effective medium for communicating information related to standards throughout the DOE community. Technical standards are used to transfer technology and standardize work processes to produce consistent, acceptable results. They provide a practical solution to the Department`s challenge to protect the environment and the health and safety of the public and workers during all facility operations. Through standards, the technologies of industries and governments worldwide are available to DOE. The DOE Technical Standards Program, a Department-wide effort that crosscuts all organizations and disciplines, links the Department to those technologies.

  12. [Standardization of hospital feeding].

    Science.gov (United States)

    Caracuel García, Ángel Manuel

    2015-05-07

    Normalization can be understood as the establishing measures against repetitive situations through the development, dissemination, and application of technical design documents called standards. In Andalusia there are 45 public hospitals with 14,606 beds, and in which 11,700 full pensions / day are served. The Working Group on Hospital Food Standardization of the Andalusian Society for Clinical Nutrition and Dietetics, started in 2010, working on the certification of suppliers, product specifications, and meals technical card. - Develop a specific tool to help improving food safety through the certification of their suppliers. - Develop a standardized technical specifications of foodstuffs necessary for the development of menus established codes diets Andalusian hospitals document. - Develop a catalog of data sheets plates of hospital meals, to homogenize menus, respecting local and unifying criteria for qualitative and quantitative ingredients. - Providing documentation and studying of several public hospitals in Andalusia: • Product specifications and certification of suppliers. • International standards certification and distribution companies. • Legislation. • Data sheets for the menu items. • Specifications of different product procurement procedures. - Development of the draft standard HOSPIFOOD®, and approval of the version “0.0”. - Training course for auditors to this standard. - Development of a raw materials catalog as technical cards. - Meals Technical cards review and election of the ones which will be part of the document. After nearly three years of work, we have achieved the following products: - Standardized database of technical specifications for the production of food dietary codes for: fish, seafood, meat and meat products, meats and pates, ready meals, bread and pastries, preserves, milk and dairy products, oils, cereals, legumes , vegetables, fruits, fresh and frozen vegetables, condiments and spices. - Standardized database of

  13. The Gold Standard Programme

    DEFF Research Database (Denmark)

    Neumann, Tim; Rasmussen, Mette; Ghith, Nermin

    2013-01-01

    To evaluate the real-life effect of an evidence-based Gold Standard Programme (GSP) for smoking cessation interventions in disadvantaged patients and to identify modifiable factors that consistently produce the highest abstinence rates.......To evaluate the real-life effect of an evidence-based Gold Standard Programme (GSP) for smoking cessation interventions in disadvantaged patients and to identify modifiable factors that consistently produce the highest abstinence rates....

  14. Beyond the standard model

    International Nuclear Information System (INIS)

    Pleitez, V.

    1994-01-01

    The search for physics laws beyond the standard model is discussed in a general way, and also some topics on supersymmetry theories. An approach is made on recent possibilities rise in the leptonic sector. Finally, models with SU(3) c X SU(2) L X U(1) Y symmetry are considered as alternatives for the extensions of the elementary particles standard model. 36 refs., 1 fig., 4 tabs

  15. Results from SAGE

    Energy Technology Data Exchange (ETDEWEB)

    Vermul, V.M.; Abdurashitov, J.N.; Bowles, T.J.; Cherry, M.L.; Cleveland, B.T.; Davis, R.; Elliott, S.R.; Gavrin, V.N.; Girin, S.V.; Gorbachev, V.V.; Ibragimova, T.V.; Kalikhov, A.V.; Khairnasov, N.G.; Knodel, T.V.; Lande, K.; Mirmov, I.N.; Nico, J.S.; Shikhin, A.A.; Teasdale, W.A.; Veretenkin, E.P.; Wark, D.L.; Wildenhain, P.S.; Wilkerson, J.F.; Yants, V.E.; Zatsepin, G.T

    2002-07-01

    We report the results of 11 years of solar neutrino observation by the Russian-American Gallium solar neutrino Experiment (SAGE). The overall result of 84 runs during the measurement period January 1990 through March 2001 is 75.6 +5.9/-5.8 (stat.) +3.5/-3.0 (syst.) SNU. This represents only slightly more than half of the predicted standard solar model rate of 129 SNU. The individual results of each run, as well as the results of combined analysis of all runs are presented.

  16. Results from SAGE

    CERN Document Server

    Vermul, V M; Bowles, T J; Cherry, M L; Cleveland, B T; Davis, R; Elliott, S R; Gavrin, V N; Girin, S V; Gorbachev, V V; Ibragimova, T V; Kalikhov, A V; Khairnasov, N G; Knodel, T V; Lande, K; Mirmov, I N; Nico, J S; Shikhin, A A; Teasdale, W A; Veretenkin, E P; Vermul, V M; Wark, D L; Wildenhain, P S; Wilkerson, J F; Yants, V E; Zatsepin, G T

    2002-01-01

    We report the results of 11 years of solar neutrino observation by the Russian-American Gallium solar neutrino Experiment (SAGE). The overall result of 84 runs during the measurement period January 1990 through March 2001 is 75.6 +5.9/-5.8 (stat.) +3.5/-3.0 (syst.) SNU. This represents only slightly more than half of the predicted standard solar model rate of 129 SNU. The individual results of each run, as well as the results of combined analysis of all runs are presented.

  17. Technical standards in nuclear area

    International Nuclear Information System (INIS)

    Grimberg, M.

    1978-01-01

    The technical standardization in nuclear area is discussed. Also, the competence of CNEN in standardization pursuit is analysed. Moreover, the process of working up of technical standards is explained; in addition, some kinds of technical standards are discussed. (author) [pt

  18. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  19. Preparation of high purity plutonium oxide for radiochemistry instrument calibration standards and working standards

    International Nuclear Information System (INIS)

    Wong, A.S.; Stalnaker, N.D.

    1997-04-01

    Due to the lack of suitable high level National Institute of Standards and Technology (NIST) traceable plutonium solution standards from the NIST or commercial vendors, the CST-8 Radiochemistry team at Los Alamos National Laboratory (LANL) has prepared instrument calibration standards and working standards from a well-characterized plutonium oxide. All the aliquoting steps were performed gravimetrically. When a 241 Am standardized solution obtained from a commercial vendor was compared to these calibration solutions, the results agreed to within 0.04% for the total alpha activity. The aliquots of the plutonium standard solutions and dilutions were sealed in glass ampules for long term storage

  20. DOE technical standards list. Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listing of current DOE technical standards, non-Government standards that have been adopted by DOE, other Government documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  1. Complex carotid cavernous sinus fistulas Barrow type D: endovascular treatment via the ophthalmic vein, imaging control with standardized MRI, long-term results; Interdisziplinaere Embolisation spontaner Karotis-Cavernosus-Fisteln Typ D nach Barrow ueber die Vena ophthalmica: klinische Langzeitergebnisse und kernspintomografische Befunde

    Energy Technology Data Exchange (ETDEWEB)

    Struffert, T.; Grunwald, I.Q.; Reith, W. [Abteilung fuer Diagnostische und Interventionelle Neuroradiologie, Universitaetsklinikum des Saarlandes (Germany); Muecke, I. [Klinik fuer Augenheilkunde, Universitaetsklinikum des Saarlandes (Germany)

    2007-04-15

    Purpose: Since feeding arteries from both the internal and external carotid artery are common, cavernous fistulas of Barrow type D are difficult to treat. Embolization using the transarterial approach is considered to be the standard therapy. However, it is often impossible to embolize feeders from the internal carotid artery. The transorbital approach after anterior orbitotomy through the ophthalmic vein is an alternative in this complex situation. The following reports our experience with three female patients who underwent transvenous embolization. Procedural success was documented using standardized MRI and clinical reevaluation. Materials and Methods: Three female patients between 57 and 78 years of age were diagnosed with carotid cavernous fistulas by conventional angiogram. All patients were suffering from exophthalmus and visual impairment. Two patients showed secondary glaucoma and diplopia. In one patient we performed a technically successful transarterial embolization using particles, but no relevant improvement of the patient's condition was seen. Transfemoral transvenous access via the sinus petrosus was not possible in any patient. All patients were then embolized via the ophthalmic vein using GDC detachable coils. All patients were clinically reevaluated by an ophthalmologist. Also a standardized MRI was performed for documentation. Follow-up was performed for the first patient for 32 months, for the second patient for 34 months and for the third patient for 50 months. Results: Transvenous embolization was technically successful in all three cases. Clinical symptoms disappeared rapidly. Postprocedural MRI showed a symmetric diameter of the ophthalmic vein. Venous congestion of the orbit caused by fatty tissue edema regressed completely. Contrast-enhanced magnetic resonance angiography showed normal arterial vessels without evidence of fistula. (orig.)

  2. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    This Department of Energy (DOE) technical standards list (TSL) has been prepared by the Office of Nuclear Safety Policy and Standards (EH-31) on the basis of currently available technical information. Periodic updates of this TSL will be issued as additional information is received on standardization documents being issued, adopted, or canceled by DOE. This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listings of current DOE technical standards, non-Government standards that have been adopted by DOE, other standards-related documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  3. IAEA Safety Standards

    International Nuclear Information System (INIS)

    2016-09-01

    The IAEA Safety Standards Series comprises publications of a regulatory nature covering nuclear safety, radiation protection, radioactive waste management, the transport of radioactive material, the safety of nuclear fuel cycle facilities and management systems. These publications are issued under the terms of Article III of the IAEA’s Statute, which authorizes the IAEA to establish “standards of safety for protection of health and minimization of danger to life and property”. Safety standards are categorized into: • Safety Fundamentals, stating the basic objective, concepts and principles of safety; • Safety Requirements, establishing the requirements that must be fulfilled to ensure safety; and • Safety Guides, recommending measures for complying with these requirements for safety. For numbering purposes, the IAEA Safety Standards Series is subdivided into General Safety Requirements and General Safety Guides (GSR and GSG), which are applicable to all types of facilities and activities, and Specific Safety Requirements and Specific Safety Guides (SSR and SSG), which are for application in particular thematic areas. This booklet lists all current IAEA Safety Standards, including those forthcoming

  4. GISB: Efficiency through standardization

    International Nuclear Information System (INIS)

    White, B.

    1995-01-01

    For those who participated in the numerous day-long development sessions held in the dim, stale basement auditorium of the Department of Energy, the ida that the Gas Industry standards Board (GISB) would be producing standards anytime soon seemed a distant dream. However, the hazy vision of just over a year ago has now become a reality. As summer turns to fall and young gas schedulers throughout this country dream of the gridiron, GISB will have already issued a model electronic-trading partner agreement and 12 standards for capacity-release transactions, as well as three standards for nomination-related transactions. Under the steady hand of Executive directors Rae McQuade and a board of director that looks like a Who's Who of the gas industry, GISB has developed into a organization that will directly influence how gas is purchased, transported, and accounted and paid for in the 21st century. The paper describes the background of the organization, standards that have been released, and issues still to be addressed

  5. Sports eyewear protective standards.

    Science.gov (United States)

    Dain, Stephen J

    2016-01-01

    Eye injuries sustained during sport comprise up to 20 per cent of all injuries to the eye serious enough for medical attention to be sought. The prevalence of eye injuries in sport is not easily assessed due to lack of authoritative participation rates, so most studies report total numbers in a time period. The evidence on the proportion of all ocular injuries that are from sport is reviewed. The relative frequencies in different sports are compared in a qualitative manner and the sports with greater numbers of ocular injuries are detailed. In common with occupational injuries to the eye, most sports eye injuries are considered preventable. The hierarchy of action for occupational risk is detailed and adapted to use in a sports scenario. All the available international, regional and national standards on sports eye protection are detailed and their provisions compared. The major function of the standards is to provide adequate protection against the hazard of the sport concerned. These are detailed and compared as a function of energy transfer. Eye protection must not introduce additional or secondary hazards (for instance, fracturing into sharp fragments on impact) and not introduce features that would deter the wearing of eye protection (for instance, restricting field of view to impede playing the sport). The provisions of the standards intended to limit secondary hazards are detailed and compared. The need for future work in standards writing and the activities of the International Standardization Organization in sports eye protection are detailed. © 2016 Optometry Australia.

  6. Standardization of splash device

    Science.gov (United States)

    Fernández Raga, María; Peters, Piet

    2017-04-01

    The erosion is a complex process that has been studied extensively by numerous researchers, requiring a prolongued time effort and a large economic investment. To be effective, the measurements of erosion should be precise, controlled and replicable, and to assure efectiveness, measurement devices of erosion should be properly designed, constructed, well calibrated and also they should be operated by a trained person (Stroosnijder, 2005). Because researchers try to improve old devices, the equipment is constantly being redesigned, making the measurements not comparable and furthermore, producing a lack of available standarized device. The lack of standardization of erosion equipment is more obvious in the case of the local splash erosion, where the nature of the process makes very difficult to isolate its effects. In this article we compare the results obtained from five of the most common splash erosion devices (selected from more than 16 different currently types), under the same rain conditions, with the objective of facilitate the standardization of the method that will be more easy to build, minimizing the error. A set of six splash devices were setted in well known positions under simulated rain, to measured the differences, among devices and the accuracy of the data recovered after 10 minutes of rainfall simulation under different intensities (from 60 to 130 mm/h). The rainfall simulator of Wageningen was used, using sand as splash erosion source. Differences in the infiltration were also measured, and a calibration of sizes and speeds of the raindrops was done using the photography method (Hamidreza-Sadeghi et al., 2013). The splash devices selected for this study were unbounded splash devices (like the funnel, the cup (Fernandez-Raga et al., 2010) and the splash flume (Jomaa et al., 2010)), and bounded devices that allow the calculation of splash rate, (like the new cup (Scholten et al., 2011) and the Morgan tray). The behaviour of different splash devices

  7. Tevatron physics results

    CERN Multimedia

    CERN. Geneva

    2007-01-01

    I will summarize the physics results from the Tevatron experiments with particular emphasis on the experimental methods used in different kinds of analysis. In particular, the Tevatron is a proton-antiproton collider that has now accumulated more than 2 fb^-1 of luminosity in the two experiments, called CDF and D0. In this lecture I will review the results on inclusive productions of jets, W- and Z-bosons, the results in the flavor sector, the measurements of top production, searches for Higgs boson production and searches for physics beyond the Standard Model. In each case I will explain the basic experimental concepts and methods needed for making the measurement.

  8. Standards and quality

    CERN Document Server

    El-Tawil, Anwar

    2015-01-01

    The book brings together a number of subjects of prime importance for any practicing engineer and, students of engineering. The book explains the concepts and functions of voluntary standards, mandatory technical regulations, conformity assessment (testing and measurement of products), certification, quality and quality management systems as well as other management systems such as environmental, social responsibility and food safety management systems.The book also gives a comprehensive description of the role of metrology systems that underpin conformity assessment. A description is given of typical national systems of standards, quality and metrology and how they relate directly or through regional structures to international systems. The book also covers the relation between standards and trade and explains the context and stipulations of the Technical Barriers to Trade Agreement of the World Trade Organization (WTO).

  9. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1983-10-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes. As appropriate, these standards will be revised periodically to accommodate comments and reflect new information or experience

  10. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  11. The standard model and beyond

    International Nuclear Information System (INIS)

    Marciano, W.J.

    1989-05-01

    In these lectures, my aim is to present a status report on the standard model and some key tests of electroweak unification. Within that context, I also discuss how and where hints of new physics may emerge. To accomplish those goals, I have organized my presentation as follows. I survey the standard model parameters with particular emphasis on the gauge coupling constants and vector boson masses. Examples of new physics appendages are also commented on. In addition, I have included an appendix on dimensional regularization and a simple example which employs that technique. I focus on weak charged current phenomenology. Precision tests of the standard model are described and up-to-date values for the Cabibbo-Kobayashi-Maskawa (CKM) mixing matrix parameters are presented. Constraints implied by those tests for a 4th generation, extra Z' bosons, and compositeness are discussed. An overview of the physics of tau decays is also included. I discuss weak neutral current phenomenology and the extraction of sin 2 θW from experiment. The results presented there are based on a global analysis of all existing data. I have chosen to concentrate that discussion on radiative corrections, the effect of a heavy top quark mass, implications for grand unified theories (GUTS), extra Z' gauge bosons, and atomic parity violation. The potential for further experimental progress is also commented on. Finally, I depart from the narrowest version of the standard model and discuss effects of neutrino masses, mixings, and electromagnetic moments. 32 refs., 3 figs., 5 tabs

  12. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1987-05-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes

  13. The Standard Model

    Science.gov (United States)

    Burgess, Cliff; Moore, Guy

    2012-04-01

    List of illustrations; List of tables; Preface; Acknowledgments; Part I. Theoretical Framework: 1. Field theory review; 2. The standard model: general features; 3. Cross sections and lifetimes; Part II. Applications: Leptons: 4. Elementary boson decays; 5. Leptonic weak interactions: decays; 6. Leptonic weak interactions: collisions; 7. Effective Lagrangians; Part III. Applications: Hadrons: 8. Hadrons and QCD; 9. Hadronic interactions; Part IV. Beyond the Standard Model: 10. Neutrino masses; 11. Open questions, proposed solutions; Appendix A. Experimental values for the parameters; Appendix B. Symmetries and group theory review; Appendix C. Lorentz group and the Dirac algebra; Appendix D. ξ-gauge Feynman rules; Appendix E. Metric convention conversion table; Select bibliography; Index.

  14. Standard for metric practice

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This standard gives guidance for application of the modernized metric system in the United States. The International System of Units, developed and maintained by the General Conference on Weights and Measures (abbreviated CGPM from the official French name Conference Generale des Poids et Measures) is intended as a basis for worldwide standardization of measurement units. The name International System of Units and the international abbreviation SI 2 were adopted by the 11th CGPM in 1960. SI is a complete, coherent system that is being universally adopted

  15. Coordinate Standard Measurement Development

    Energy Technology Data Exchange (ETDEWEB)

    Hanshaw, R.A.

    2000-02-18

    A Shelton Precision Interferometer Base, which is used for calibration of coordinate standards, was improved through hardware replacement, software geometry error correction, and reduction of vibration effects. Substantial increases in resolution and reliability, as well as reduction in sampling time, were achieved through hardware replacement; vibration effects were reduced substantially through modification of the machine component dampening and software routines; and the majority of the machine's geometry error was corrected through software geometry error correction. Because of these modifications, the uncertainty of coordinate standards calibrated on this device has been reduced dramatically.

  16. Islam, Standards, and Technoscience

    DEFF Research Database (Denmark)

    Fischer, Johan

    Halal (literally, "permissible" or "lawful") production, trade, and standards have become essential to state-regulated Islam and to companies in contemporary Malaysia and Singapore, giving these two countries a special position in the rapidly expanding global market for halal products: in these n......Halal (literally, "permissible" or "lawful") production, trade, and standards have become essential to state-regulated Islam and to companies in contemporary Malaysia and Singapore, giving these two countries a special position in the rapidly expanding global market for halal products...

  17. How meaningful are risk determinations in the absence of a complete dataset? Making the case for publishing standardized test guideline and ‘no effect’ studies for evaluating the safety of nanoparticulates versus spurious ‘high effect’ results from single investigative studies

    Science.gov (United States)

    Warheit, David B.; Donner, E. Maria

    2015-06-01

    A recent review article critically assessed the effectiveness of published research articles in nanotoxicology to meaningfully address health and safety issues for workers and consumers. The main conclusions were that, based on a number of flaws in study designs, the potential risk from exposures to nanomaterials is highly exaggerated, and that no ‘nano-specific’ adverse effects, different from exposures to bulk particles, have been convincingly demonstrated. In this brief editorial we focus on a related tangential issue which potentially compromises the integrity of basic risk science. We note that some single investigation studies report specious toxicity findings, which make the conclusions more alarming and attractive and publication worthy. In contrast, the standardized, carefully conducted, ‘guideline study results’ are often ignored because they can frequently report no adverse effects; and as a consequence are not considered as novel findings for publication purposes, and therefore they are never considered as newsworthy in the popular press. Yet it is the Organization for Economic Cooperation and Development (OECD) type test guideline studies that are the most reliable for conducting risk assessments. To contrast these styles and approaches, we present the results of a single study which reports high toxicological effects in rats following low-dose, short-term oral exposures to nanoscale titanium dioxide particles concomitant with selective investigative analyses. Alternatively, the findings of OECD test guideline 408, standardized guideline oral toxicity studies conducted for 90 days at much higher doses (1000 mg kg-1) in male and female rats demonstrated no adverse effects following a very thorough and complete clinical chemical, as well as histopathological evaluation of all of the relevant organs in the body. This discrepancy in study findings is not reconciled by the fact that several biokinetic studies in rats and humans demonstrate little or

  18. How meaningful are risk determinations in the absence of a complete dataset? Making the case for publishing standardized test guideline and ‘no effect’ studies for evaluating the safety of nanoparticulates versus spurious ‘high effect’ results from single investigative studies

    International Nuclear Information System (INIS)

    Warheit, David B; Donner, E Maria

    2015-01-01

    A recent review article critically assessed the effectiveness of published research articles in nanotoxicology to meaningfully address health and safety issues for workers and consumers. The main conclusions were that, based on a number of flaws in study designs, the potential risk from exposures to nanomaterials is highly exaggerated, and that no ‘nano-specific’ adverse effects, different from exposures to bulk particles, have been convincingly demonstrated. In this brief editorial we focus on a related tangential issue which potentially compromises the integrity of basic risk science. We note that some single investigation studies report specious toxicity findings, which make the conclusions more alarming and attractive and publication worthy. In contrast, the standardized, carefully conducted, ‘guideline study results’ are often ignored because they can frequently report no adverse effects; and as a consequence are not considered as novel findings for publication purposes, and therefore they are never considered as newsworthy in the popular press. Yet it is the Organization for Economic Cooperation and Development (OECD) type test guideline studies that are the most reliable for conducting risk assessments. To contrast these styles and approaches, we present the results of a single study which reports high toxicological effects in rats following low-dose, short-term oral exposures to nanoscale titanium dioxide particles concomitant with selective investigative analyses. Alternatively, the findings of OECD test guideline 408, standardized guideline oral toxicity studies conducted for 90 days at much higher doses (1000 mg kg −1 ) in male and female rats demonstrated no adverse effects following a very thorough and complete clinical chemical, as well as histopathological evaluation of all of the relevant organs in the body. This discrepancy in study findings is not reconciled by the fact that several biokinetic studies in rats and humans demonstrate

  19. Fiscal 1997 report on the results of the international standardization R and D. Study of safety of laser and light emitting diodes (LED) for human body; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Laser, oyobi hakko diode (LED) ni taisuru jintai eno anzensei no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    LD and LED are used in a wide range from telecommunication systems to residential/commercial equipment. Optical semiconductor devices existing in the domain between LD and LED are also being commercialized. In the field of this project, there are a lot of contradictions about the international standards. For the purpose of promoting the common understanding of standards and improving the consistency, the paper examined mainly safety, principles of motion and various applications of laser and LED, and developed international standards for the output measuring method. At the same time, the paper systematically studied the biological safety, determined regulatory values which were backed up as safety standards, and proposed/worked out a draft for new international standardization for safety of LED. Further, by the definition of laser in general, standards related to a lot of TCs among ISO and IEC standards were harmonized for the common understanding on the basis of a common idea. 40 refs., 163 figs., 6 tabs.

  20. Standard Weights and Measures

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 8. Standard Weights and Measures. Vasant Natarajan. General Article Volume 6 Issue 8 August 2001 pp 44-59. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/006/08/0044-0059. Author Affiliations.

  1. International Financial Reporting Standards

    DEFF Research Database (Denmark)

    Pontoppidan, Caroline Aggestam

    2011-01-01

    The advance of International Financial Reporting Standards (IFRS) across the globe has accelerated over the last few years. This is placing increasing demands on educators to respond to these changes by an increased focus on IFRS in the curricula of accounting students. This paper reviews a range...

  2. Beyond the Standard Model

    CERN Document Server

    Csáki, Csaba

    2015-01-01

    We introduce aspects of physics beyond the Standard Model focusing on supersymmetry, extra dimensions, and a composite Higgs as solutions to the Hierarchy problem. Lectures given at the 2013 European School of High Energy Physics, Parádfürdo, Hungary, 5-18 June 2013.

  3. Standardized Curriculum for Cosmetology.

    Science.gov (United States)

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    Standardized curricula are provided for two courses for the secondary vocational education program in Mississippi: cosmetology I and II. The 18 units in cosmetology I are as follows: introduction to cosmetology; Vocational Industrial Clubs of America; the look you like; bacteriology; sterilization and sanitation; hair and disorders; draping,…

  4. Standardization of Sign Languages

    Science.gov (United States)

    Adam, Robert

    2015-01-01

    Over the years attempts have been made to standardize sign languages. This form of language planning has been tackled by a variety of agents, most notably teachers of Deaf students, social workers, government agencies, and occasionally groups of Deaf people themselves. Their efforts have most often involved the development of sign language books…

  5. Islam, Standards, and Technoscience

    DEFF Research Database (Denmark)

    Fischer, Johan

    Halal (literally, "permissible" or "lawful") production, trade, and standards have become essential to state-regulated Islam and to companies in contemporary Malaysia and Singapore, giving these two countries a special position in the rapidly expanding global market for halal products: in these n......Halal (literally, "permissible" or "lawful") production, trade, and standards have become essential to state-regulated Islam and to companies in contemporary Malaysia and Singapore, giving these two countries a special position in the rapidly expanding global market for halal products......, this book provides an exploration of the role of halal production, trade, and standards. Fischer explains how the global markets for halal comprise divergent zones in which Islam, markets, regulatory institutions, and technoscience interact and diverge. Focusing on the "bigger institutional picture......" that frames everyday halal consumption, Fischer provides a multisited ethnography of the overlapping technologies and techniques of production, trade, and standards that together warrant a product as "halal," and thereby help to format the market. Exploring global halal in networks, training, laboratories...

  6. Low Impact Development Standards

    Energy Technology Data Exchange (ETDEWEB)

    Loftin, Samuel R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-02

    The goal of the LID Standards is to provide guidance on the planning, design, construction and maintenance of green infrastructure (GI) features at Los Alamos National Laboratory. The success of LID at LANL is dependent on maintaining a consistent approach to achieve effective application, operation, and maintenance of these storm water control features.

  7. Elevating standards, improving safety.

    Science.gov (United States)

    Clarke, Richard

    2014-08-01

    In our latest 'technical guidance' article, Richard Clarke, sales and marketing director at one of the UK's leading lift and escalator specialists, Schindler, examines some of the key issues surrounding the specification, maintenance, and operation of lifts in hospitals to help ensure the highest standards of safety and reliability.

  8. Beyond the standard model

    International Nuclear Information System (INIS)

    Cuypers, F.

    1997-05-01

    These lecture notes are intended as a pedagogical introduction to several popular extensions of the standard model of strong and electroweak interactions. The topics include the Higgs sector, the left-right symmetric model, grand unification and supersymmetry. Phenomenological consequences and search procedures are emphasized. (author) figs., tabs., 18 refs

  9. Standard hakkab tootma Mercedesele

    Index Scriptorium Estoniae

    2005-01-01

    AS Standard sõlmis ühe maailma suurema autotootjaga DaimlerChrysler AG koostöölepingu, mille kohaselt hakkab ettevõte tootma ning müüma kontori- ja teenindussaalide mööblit kontserni kuuluva Mercedes-Benzi Euroopa diileritele

  10. Mixed RIA standard

    International Nuclear Information System (INIS)

    Talan, P.; Mucha, J.; Krizan, J.

    1986-01-01

    For the radioimmunoassay of digoxin, 3,5,3'-triiodothyronine, 17β-estradiol, progesterone, testosterone and α 1 -fetoprotein a mixed standard was prepared of these substances in a gamma globulin solution at a concentration of 0.8 to 1.4 wt.% in an aqueous buffer at pH within the range of 6 - 9. The standard contains digoxin at a concentration of 10 -4 to 10 nmol/l, 17β-estradiol at 10 -4 to 2 nmol/l, progesteron at 10 -4 to 100 nmol/l, testosterone at 1o -4 to 21 nmol/l, and α 1 -fetoprotein at 10 -4 to 10 nmol/l with at least two of these substances having concentrations higher than 10 -3 nmol/l. Examples are given of the preparation of the mixed standard with different concentrations of the components. The use of the standard has the following advantages: it is labor saving, reduces the risk of failure in the manufacture of RIA kits, eliminates mistakes in the selection of kits for the determination of different substances and allows a more economical use of material. (E.S.)

  11. Beyond the Standard Model

    CERN Multimedia

    CERN. Geneva

    2005-01-01

    The necessity for new physics beyond the Standard Model will be motivated. Theoretical problems will be exposed and possible solutions will be described. The goal is to present the exciting new physics ideas that will be tested in the near future. Supersymmetry, grand unification, extra dimensions and string theory will be presented.

  12. DOE standard: Radiological control

    International Nuclear Information System (INIS)

    1999-07-01

    The Department of Energy (DOE) has developed this Standard to assist line managers in meeting their responsibilities for implementing occupational radiological control programs. DOE has established regulatory requirements for occupational radiation protection in Title 10 of the Code of Federal Regulations, Part 835 (10 CFR 835), ''Occupational Radiation Protection''. Failure to comply with these requirements may lead to appropriate enforcement actions as authorized under the Price Anderson Act Amendments (PAAA). While this Standard does not establish requirements, it does restate, paraphrase, or cite many (but not all) of the requirements of 10 CFR 835 and related documents (e.g., occupational safety and health, hazardous materials transportation, and environmental protection standards). Because of the wide range of activities undertaken by DOE and the varying requirements affecting these activities, DOE does not believe that it would be practical or useful to identify and reproduce the entire range of health and safety requirements in this Standard and therefore has not done so. In all cases, DOE cautions the user to review any underlying regulatory and contractual requirements and the primary guidance documents in their original context to ensure that the site program is adequate to ensure continuing compliance with the applicable requirements. To assist its operating entities in achieving and maintaining compliance with the requirements of 10 CFR 835, DOE has established its primary regulatory guidance in the DOE G 441.1 series of Guides. This Standard supplements the DOE G 441.1 series of Guides and serves as a secondary source of guidance for achieving compliance with 10 CFR 835

  13. DOE standard: Radiological control

    Energy Technology Data Exchange (ETDEWEB)

    1999-07-01

    The Department of Energy (DOE) has developed this Standard to assist line managers in meeting their responsibilities for implementing occupational radiological control programs. DOE has established regulatory requirements for occupational radiation protection in Title 10 of the Code of Federal Regulations, Part 835 (10 CFR 835), ``Occupational Radiation Protection``. Failure to comply with these requirements may lead to appropriate enforcement actions as authorized under the Price Anderson Act Amendments (PAAA). While this Standard does not establish requirements, it does restate, paraphrase, or cite many (but not all) of the requirements of 10 CFR 835 and related documents (e.g., occupational safety and health, hazardous materials transportation, and environmental protection standards). Because of the wide range of activities undertaken by DOE and the varying requirements affecting these activities, DOE does not believe that it would be practical or useful to identify and reproduce the entire range of health and safety requirements in this Standard and therefore has not done so. In all cases, DOE cautions the user to review any underlying regulatory and contractual requirements and the primary guidance documents in their original context to ensure that the site program is adequate to ensure continuing compliance with the applicable requirements. To assist its operating entities in achieving and maintaining compliance with the requirements of 10 CFR 835, DOE has established its primary regulatory guidance in the DOE G 441.1 series of Guides. This Standard supplements the DOE G 441.1 series of Guides and serves as a secondary source of guidance for achieving compliance with 10 CFR 835.

  14. Hg(+) Frequency Standards

    Science.gov (United States)

    Prestage, John D.; Tjoelker, Robert L.; Maleki, Lute

    2000-01-01

    In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

  15. Department of Energy Standards Index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This TSL, intended for use in selecting and using DOE technical standards and other Government and non-Government standards, provides listing of current and inactive DOE technical standards, non-Government standards adopted by DOE, other Government documents in which DOE has a recorded interest, and cancelled DOE technical standards.

  16. INTERNATIONAL COMPARISON OF STANDARDS OF MUTUAL INDUCTANCE,

    Science.gov (United States)

    from the metre and second by the use of similar Campbell standards of mutual inductance. A direct comparison of the units of inductance derived in...the two laboratories has been made, using a third Campbell standard whose value was determined electrically. Comparison of the results established by

  17. The role of food standards in development

    DEFF Research Database (Denmark)

    Trifkovic, Neda

    of the emergence of food standards on farmers’ wellbeing, (ii) the effects of various forms of vertical coordination on household welfare and (iii) the consequences of the concurrent emergence of food standards and vertical coordination in the Vietnamese pangasius sector. The first paper, Food Standards are Good...... — for Middle-Class Farmers, joint with Henrik Hansen, estimates the impact of food standards on farmers’ wellbeing using the data from the Vietnamese pangasius sector. In this paper we estimate both the average effect as well as the effects on poorer and richer farmers using the instrumental variable quantile...... regression. We find that large returns from food standards are possible but the gains are substantial only for the ‘middle-class’ farmers, occupying the range between 50% and 85% quantiles of the expenditure distribution. Overall, this result points to an exclusionary impact of food standards for the poorest...

  18. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This technical standards list (TSL) was prepared for use by personnel involved in the selection and use of US DOE technical standards and other government and non-government standards. This TSL provides listings of current DOE technical standards, non-government standards that have been adopted by DOE, other government documents in which DOE has a recorded interest, and cancelled DOE technical standards. Standards are indexed by type in the appendices to this document. Definitions of and general guidance for the use of standards are also provided.

  19. Comparisons of ASTM standards cited in the NRC standard review plan, NUREG-0800 and related documents

    Energy Technology Data Exchange (ETDEWEB)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Pawlowski, R.A.; Spiesman, J.B.

    1995-10-01

    This report provides the results of comparisons of the cited and latest versions of ASTM standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC`s Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review.

  20. Comparisons of ANSI standards cited in the NRC standard review plan, NUREG-0800 and related documents

    International Nuclear Information System (INIS)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Pawlowski, R.A.; Spiesman, J.B.

    1995-11-01

    This report provides the results of comparisons of the cited and latest versions of ANSI standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC's Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review

  1. Comparisons of ANSI standards cited in the NRC standard review plan, NUREG-0800 and related documents

    Energy Technology Data Exchange (ETDEWEB)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Pawlowski, R.A.; Spiesman, J.B. [Pacific Northwest Lab., Richland, WA (United States)

    1995-11-01

    This report provides the results of comparisons of the cited and latest versions of ANSI standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC`s Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review.

  2. Comparisons of ASTM standards cited in the NRC standard review plan, NUREG-0800 and related documents

    International Nuclear Information System (INIS)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Pawlowski, R.A.; Spiesman, J.B.

    1995-10-01

    This report provides the results of comparisons of the cited and latest versions of ASTM standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC's Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review

  3. Recent results from CMS

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    With the increase in center-of-mass energy, a new energy frontier has been opened by the Large Hadron Collider. More than 25 fb^-1 of proton-proton collisions at sqrt(s)=13 TeV have been delivered to both ATLAS and CMS experiments during 2016. This enormous dataset can be used to test the Standard Model in a complete new regime with tremendous precision and it has the potential to unveil new physics or set strong bounds on it. In this talk some of the most recent results made public by the CMS Collaboration will be presented. The focus will mainly be on searches for physics beyond the Standard Model, with particular emphasis on searches for dark matter candidates.

  4. Beyond the Standard Model

    Energy Technology Data Exchange (ETDEWEB)

    Peskin, M.E.

    1997-05-01

    These lectures constitute a short course in ``Beyond the Standard Model`` for students of experimental particle physics. The author discusses the general ideas which guide the construction of models of physics beyond the Standard model. The central principle, the one which most directly motivates the search for new physics, is the search for the mechanism of the spontaneous symmetry breaking observed in the theory of weak interactions. To illustrate models of weak-interaction symmetry breaking, the author gives a detailed discussion of the idea of supersymmetry and that of new strong interactions at the TeV energy scale. He discusses experiments that will probe the details of these models at future pp and e{sup +}e{sup {minus}} colliders.

  5. Beyond the Standard Model

    International Nuclear Information System (INIS)

    Peskin, M.E.

    1997-05-01

    These lectures constitute a short course in ''Beyond the Standard Model'' for students of experimental particle physics. The author discusses the general ideas which guide the construction of models of physics beyond the Standard model. The central principle, the one which most directly motivates the search for new physics, is the search for the mechanism of the spontaneous symmetry breaking observed in the theory of weak interactions. To illustrate models of weak-interaction symmetry breaking, the author gives a detailed discussion of the idea of supersymmetry and that of new strong interactions at the TeV energy scale. He discusses experiments that will probe the details of these models at future pp and e + e - colliders

  6. Non_standard Wood

    DEFF Research Database (Denmark)

    Tamke, Martin

    . Using parametric design tools and computer controlled production facilities Copenhagens Centre for IT and Architecture undertook a practice based research into performance based non-standard element design and mass customization techniques. In close cooperation with wood construction software......Non-Standard elements in architecture bear the promise of a better more specific performance (Oosterhuis 2003). A new understanding of design evolves, which is focusing on open ended approaches, able to negotiate between shifting requirements and to integrate knowledge on process and material......, but the integration of traditional wood craft techniques. The extensive use of self adjusting, load bearing wood-wood joints contributed to ease in production and assembly of a performance based architecture....

  7. Standardization of Speech Corpus

    Directory of Open Access Journals (Sweden)

    Ai-jun Li

    2007-12-01

    Full Text Available Speech corpus is the basis for analyzing the characteristics of speech signals and developing speech synthesis and recognition systems. In China, almost all speech research and development affiliations are developing their own speech corpora. We have so many different kinds numbers of Chinese speech corpora that it is important to be able to conveniently share these speech corpora to avoid wasting time and money and to make research work more efficient. The primary goal of this research is to find a standard scheme which can make the corpus be established more efficiently and be used or shared more easily. A huge speech corpus on 10 regional accented Chinese, RASC863 (a Regional Accent Speech Corpus funded by National 863 Project will be exemplified to illuminate the standardization of speech corpus production.

  8. Testing the Standard Model

    CERN Document Server

    Riles, K

    1998-01-01

    The Large Electron Project (LEP) accelerator near Geneva, more than any other instrument, has rigorously tested the predictions of the Standard Model of elementary particles. LEP measurements have probed the theory from many different directions and, so far, the Standard Model has prevailed. The rigour of these tests has allowed LEP physicists to determine unequivocally the number of fundamental 'generations' of elementary particles. These tests also allowed physicists to ascertain the mass of the top quark in advance of its discovery. Recent increases in the accelerator's energy allow new measurements to be undertaken, measurements that may uncover directly or indirectly the long-sought Higgs particle, believed to impart mass to all other particles.

  9. High dilution calorimetric determination of the standard state thermodynamic differences between the properties of H+(aq) and Na+(aq) up to 598.15 K

    International Nuclear Information System (INIS)

    Djamali, Essmaiil; Cobble, James W.

    2009-01-01

    Standard state thermodynamic properties for fully ionized aqueous perrhenic acid at temperature in the range of (298.15 to 598.15) K and at p sat were determined by high dilution solution calorimetry (10 -4 m). A comparison of the standard state thermodynamic properties for fully ionized aqueous perrhenic acid, HReO 4 (aq), and sodium perrhenate, NaReO 4 (aq), establishes for the first time the quantitative values for the differences between H + (aq) and Na + (aq) from temperature of (298.15 to 598.15) K. Perrhenic acid is believed to be the first strong acid to be thermodynamically well characterized under standard state conditions to date from measurements down to 10 -4 m. The value of the Debye-Hueckel limiting slope for enthalpies of dilution at temperature of 596.30 K of 122 ± 6 kJ . mol -3/2 . kg 1/2 , obtained from the integral heats of solution measurement at various concentrations, is in good agreement with theoretical value in literature, 121 kJ . mol -3/2 . kg 1/2 . This agreement verifies that HReO 4 (aq) obeys the simple limiting law for strong electrolytes. Many thermodynamic properties of soluble sodium electrolytes can now be converted to the corresponding acid form.

  10. Standard Model physics

    CERN Multimedia

    Altarelli, Guido

    1999-01-01

    Introduction structure of gauge theories. The QEDand QCD examples. Chiral theories. The electroweak theory. Spontaneous symmetry breaking. The Higgs mechanism Gauge boson and fermion masses. Yukawa coupling. Charges current couplings. The Cabibo-Kobayashi-Maskawa matrix and CP violation. Neutral current couplings. The Glasow-Iliopoulos-Maiani mechanism. Gauge boson and Higgs coupling. Radiative corrections and loops. Cancellation of the chiral anomaly. Limits on the Higgs comparaison. Problems of the Standard Model. Outlook.

  11. Standard model and beyond

    International Nuclear Information System (INIS)

    Quigg, C.

    1984-09-01

    The SU(3)/sub c/ circle crossSU(2)/sub L/circle crossU(1)/sub Y/ gauge theory of ineractions among quarks and leptons is briefly described, and some recent notable successes of the theory are mentioned. Some shortcomings in our ability to apply the theory are noted, and the incompleteness of the standard model is exhibited. Experimental hints that Nature may be richer in structure than the minimal theory are discussed. 23 references

  12. DOE standard: Firearms safety

    International Nuclear Information System (INIS)

    1996-02-01

    Information in this document is applicable to all DOE facilities, elements, and contractors engaged in work that requires the use of firearms as provided by law or contract. The standard in this document provides principles and practices for implementing a safe and effective firearms safety program for protective forces and for non-security use of firearms. This document describes acceptable interpretations and methods for meeting Order requirements

  13. Determination of standard data

    International Nuclear Information System (INIS)

    Pychlau, P.

    1986-01-01

    The standard data used for diagnostic radiography refer to the filter system, the Bucky grid, the film type, exposure, and film processing method. The same type of reference data is established for fluoroscopic screen devices, with data on the fluoroscopic exposure time and the area exposure product in addition. The measurements are done in compliance with section 29 X-Ray Ordinance and DIN 6868. (DG) [de

  14. Non_standard Wood

    DEFF Research Database (Denmark)

    Tamke, Martin

    . Using parametric design tools and computer controlled production facilities Copenhagens Centre for IT and Architecture undertook a practice based research into performance based non-standard element design and mass customization techniques. In close cooperation with wood construction software......, but the integration of traditional wood craft techniques. The extensive use of self adjusting, load bearing wood-wood joints contributed to ease in production and assembly of a performance based architecture....

  15. DOE standard: Firearms safety

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Information in this document is applicable to all DOE facilities, elements, and contractors engaged in work that requires the use of firearms as provided by law or contract. The standard in this document provides principles and practices for implementing a safe and effective firearms safety program for protective forces and for non-security use of firearms. This document describes acceptable interpretations and methods for meeting Order requirements.

  16. New standard environmental management

    International Nuclear Information System (INIS)

    Andriola, Luca; Luciani, Roberto

    2006-01-01

    The ISO 14001:2004 standard, like ISO 9001:2000 on quality management, transcends the preventive approach (based on a rigid and more or less adequate process-management model still mainly inspired by traditional production methods) and introduces in its stead a highly flexible approach applicable to any socio-economic activity. It is structured by processes rather than system elements, and is based on the quest for efficacy and ongoing improvement [it

  17. Telemetry Standards, Part 1

    Science.gov (United States)

    2015-07-01

    protocol RCC Range Commanders Council RFC Request For Comment RIU remote interface unit RMM removable memory module RS Recommended Standard RSCF...followed by hex characters Comments COMMENTS G\\COM Allowed when: Always Provide the additional information requested or any other information desired...if applicable. Range: 6 characters Comments COMMENTS M-x\\COM Allowed when: When M\\ID is specified Provide the additional information requested or

  18. Natural matrix standards

    International Nuclear Information System (INIS)

    Bowen, V.T.

    1976-01-01

    Environmental radiochemistry needs, for use in analytical intercomparision and as standard reference materials, very large homogeneous samples of a variety of matrices, each naturally contaminated by a variety of longer-lived radionuclides, at several different ranges of concentrations. The reasons for this need are discussed, and the minimum assortment of matrices of radionuclides, and of concentrations is established. Sources of suitable materials are suggested, and the international approach to meeting this need is emphasized

  19. Standard biological parts knowledgebase.

    Science.gov (United States)

    Galdzicki, Michal; Rodriguez, Cesar; Chandran, Deepak; Sauro, Herbert M; Gennari, John H

    2011-02-24

    We have created the Knowledgebase of Standard Biological Parts (SBPkb) as a publically accessible Semantic Web resource for synthetic biology (sbolstandard.org). The SBPkb allows researchers to query and retrieve standard biological parts for research and use in synthetic biology. Its initial version includes all of the information about parts stored in the Registry of Standard Biological Parts (partsregistry.org). SBPkb transforms this information so that it is computable, using our semantic framework for synthetic biology parts. This framework, known as SBOL-semantic, was built as part of the Synthetic Biology Open Language (SBOL), a project of the Synthetic Biology Data Exchange Group. SBOL-semantic represents commonly used synthetic biology entities, and its purpose is to improve the distribution and exchange of descriptions of biological parts. In this paper, we describe the data, our methods for transformation to SBPkb, and finally, we demonstrate the value of our knowledgebase with a set of sample queries. We use RDF technology and SPARQL queries to retrieve candidate "promoter" parts that are known to be both negatively and positively regulated. This method provides new web based data access to perform searches for parts that are not currently possible.

  20. Implementing PAT with Standards

    Science.gov (United States)

    Chandramohan, Laakshmana Sabari; Doolla, Suryanarayana; Khaparde, S. A.

    2016-02-01

    Perform Achieve Trade (PAT) is a market-based incentive mechanism to promote energy efficiency. The purpose of this work is to address the challenges inherent to inconsistent representation of business processes, and interoperability issues in PAT like cap-and-trade mechanisms especially when scaled. Studies by various agencies have highlighted that as the mechanism evolves including more industrial sectors and industries in its ambit, implementation will become more challenging. This paper analyses the major needs of PAT (namely tracking, monitoring, auditing & verifying energy-saving reports, and providing technical support & guidance to stakeholders); and how the aforesaid reasons affect them. Though current technologies can handle these challenges to an extent, standardization activities for implementation have been scanty for PAT and this work attempts to evolve them. The inconsistent modification of business processes, rules, and procedures across stakeholders, and interoperability among heterogeneous systems are addressed. This paper proposes the adoption of specifically two standards into PAT, namely Business Process Model and Notation for maintaining consistency in business process modelling, and Common Information Model (IEC 61970, 61968, 62325 combined) for information exchange. Detailed architecture and organization of these adoptions are reported. The work can be used by PAT implementing agencies, stakeholders, and standardization bodies.

  1. Standard biological parts knowledgebase.

    Directory of Open Access Journals (Sweden)

    Michal Galdzicki

    2011-02-01

    Full Text Available We have created the Knowledgebase of Standard Biological Parts (SBPkb as a publically accessible Semantic Web resource for synthetic biology (sbolstandard.org. The SBPkb allows researchers to query and retrieve standard biological parts for research and use in synthetic biology. Its initial version includes all of the information about parts stored in the Registry of Standard Biological Parts (partsregistry.org. SBPkb transforms this information so that it is computable, using our semantic framework for synthetic biology parts. This framework, known as SBOL-semantic, was built as part of the Synthetic Biology Open Language (SBOL, a project of the Synthetic Biology Data Exchange Group. SBOL-semantic represents commonly used synthetic biology entities, and its purpose is to improve the distribution and exchange of descriptions of biological parts. In this paper, we describe the data, our methods for transformation to SBPkb, and finally, we demonstrate the value of our knowledgebase with a set of sample queries. We use RDF technology and SPARQL queries to retrieve candidate "promoter" parts that are known to be both negatively and positively regulated. This method provides new web based data access to perform searches for parts that are not currently possible.

  2. ISO 50001 Energy Management Standard

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-08-12

    This powerful standard from the International Organization for Standardization (ISO) provides an internationally recognized framework for organizations to voluntarily implement an energy management system.

  3. Standardization as Spaces of Diversity

    Directory of Open Access Journals (Sweden)

    Allison Marie Loconto

    2017-08-01

    Full Text Available Standards have become an important object of investigation in social science and STS scholars have called for a more systematic program of research to study standards or standardization (Busch 2011; Timmermans and Epstein 2010. In this considering concepts paper, we engage with their program for a sociology of standards and propose a new way to think about standards and standardization as “spaces of diversity” so as to push our thinking forward about how standards, standardization and innovation processes are linked. We consider standardization as the dynamic interaction in three spaces (standards in the making, standards in action, and standards in circulation where diversity reemerges only to be tentatively reduced or limited through new rounds of standard setting. We illustrate how diversity is an integral part of standardization with the example of the Rainforest Alliance standard for tea production as it circulated from Costa Rica to Kenya, where it was made and put into action and then circulated again to other African, Asian, and Latin American countries. We end with a proposition for future research on standards to address these other spaces of standards as loci of standardization and innovation.

  4. Authentication: A Standard Problem or a Problem of Standards?

    Directory of Open Access Journals (Sweden)

    Amanda Capes-Davis

    2016-06-01

    Full Text Available Reproducibility and transparency in biomedical sciences have been called into question, and scientists have been found wanting as a result. Putting aside deliberate fraud, there is evidence that a major contributor to lack of reproducibility is insufficient quality assurance of reagents used in preclinical research. Cell lines are widely used in biomedical research to understand fundamental biological processes and disease states, yet most researchers do not perform a simple, affordable test to authenticate these key resources. Here, we provide a synopsis of the problems we face and how standards can contribute to an achievable solution.

  5. Hospital standardized mortality ratio: consequences of adjusting hospital mortality with indirect standardization.

    Directory of Open Access Journals (Sweden)

    Maurice E Pouw

    Full Text Available BACKGROUND: The hospital standardized mortality ratio (HSMR is developed to evaluate and improve hospital quality. Different methods can be used to standardize the hospital mortality ratio. Our aim was to assess the validity and applicability of directly and indirectly standardized hospital mortality ratios. METHODS: Retrospective scenario analysis using routinely collected hospital data to compare deaths predicted by the indirectly standardized case-mix adjustment method with observed deaths. Discharges from Dutch hospitals in the period 2003-2009 were used to estimate the underlying prediction models. We analysed variation in indirectly standardized hospital mortality ratios (HSMRs when changing the case-mix distributions using different scenarios. Sixty-one Dutch hospitals were included in our scenario analysis. RESULTS: A numerical example showed that when interaction between hospital and case-mix is present and case-mix differs between hospitals, indirectly standardized HSMRs vary between hospitals providing the same quality of care. In empirical data analysis, the differences between directly and indirectly standardized HSMRs for individual hospitals were limited. CONCLUSION: Direct standardization is not affected by the presence of interaction between hospital and case-mix and is therefore theoretically preferable over indirect standardization. Since direct standardization is practically impossible when multiple predictors are included in the case-mix adjustment model, indirect standardization is the only available method to compute the HSMR. Before interpreting such indirectly standardized HSMRs the case-mix distributions of individual hospitals and the presence of interactions between hospital and case-mix should be assessed.

  6. ESDIS Standards Office (ESO): Requirements, Standards and Practices

    Science.gov (United States)

    Mitchell, Andrew E.; Mcinerney, Mark Allen; Enloe, Yonsok K.; Conover, Helen T.; Doyle, Allan

    2016-01-01

    The ESDIS Standards Office assists the ESDIS Project in formulating standards policy for NASA Earth Science Data Systems (ESDS), coordinates standards activities within ESDIS, and provides technical expertise and assistance with standards related tasks within the NASA Earth Science Data System Working Groups (ESDSWG). This poster summarizes information found on the earthdata.nasa.gov site that describes the ESO.

  7. 76 FR 75840 - Revising Standards Referenced in the Acetylene Standard

    Science.gov (United States)

    2011-12-05

    .... OSHA-2011-0183] RIN 1218-AC64 Revising Standards Referenced in the Acetylene Standard AGENCY: Occupational Safety and Health Administration (OSHA), Department of Labor. ACTION: Notice of proposed... standards developing organization (``SDO standards''). OSHA also is publishing a direct final rule in today...

  8. Is the Standard Model about to crater?

    CERN Multimedia

    Lane, Kenneth

    2015-01-01

    The Standard Model is coming under more and more pressure from experiments. New results from the analysis of LHC's Run 1 data show effects that, if confirmed, would be the signature of new interactions at the TeV scale.

  9. Study of federal microwave standards

    Energy Technology Data Exchange (ETDEWEB)

    David, L.

    1980-08-01

    Present and future federal regulatory processes which may impact the permissible levels of microwave radiation emitted by the SPS Microwave Power Transmission (MPTS) were studied. An historical development of US occupational and public microwave standards includes an overview of Western and East European philosophies of environmental protection and neurophysiology which have led to the current widely differing maximum permissible exposure limits to microwaves. The possible convergence of microwave standards is characterized by a lowering of Western exposure levels while Eastern countries consider standard relaxation. A trend toward stricter controls on activities perceived as harmful to public health is under way as is interest in improving the federal regulatory process. Particularly relevant to SPS is the initiation of long-term, low-level microwave exposure programs. Coupled with new developments in instrumentation and dosimetry, the results from chronic exposure program and population exposure studies could be expected within the next five to ten years. Also discussed is the increasing public concern that rf energy is yet another hazardous environmental agent.

  10. Consistency Across Standards or Standards in a New Business Model

    Science.gov (United States)

    Russo, Dane M.

    2010-01-01

    Presentation topics include: standards in a changing business model, the new National Space Policy is driving change, a new paradigm for human spaceflight, consistency across standards, the purpose of standards, danger of over-prescriptive standards, a balance is needed (between prescriptive and general standards), enabling versus inhibiting, characteristics of success-oriented standards, characteristics of success-oriented standards, and conclusions. Additional slides include NASA Procedural Requirements 8705.2B identifies human rating standards and requirements, draft health and medical standards for human rating, what's been done, government oversight models, examples of consistency from anthropometry, examples of inconsistency from air quality and appendices of government and non-governmental human factors standards.

  11. An Open Standard for Camera Trap Data

    Directory of Open Access Journals (Sweden)

    Tavis Forrester

    2016-12-01

    Full Text Available Camera traps that capture photos of animals are a valuable tool for monitoring biodiversity. The use of camera traps is rapidly increasing and there is an urgent need for standardization to facilitate data management, reporting and data sharing. Here we offer the Camera Trap Metadata Standard as an open data standard for storing and sharing camera trap data, developed by experts from a variety of organizations. The standard captures information necessary to share data between projects and offers a foundation for collecting the more detailed data needed for advanced analysis. The data standard captures information about study design, the type of camera used, and the location and species names for all detections in a standardized way. This information is critical for accurately assessing results from individual camera trapping projects and for combining data from multiple studies for meta-analysis. This data standard is an important step in aligning camera trapping surveys with best practices in data-intensive science. Ecology is moving rapidly into the realm of big data, and central data repositories are becoming a critical tool and are emerging for camera trap data. This data standard will help researchers standardize data terms, align past data to new repositories, and provide a framework for utilizing data across repositories and research projects to advance animal ecology and conservation.

  12. Competency model and standards for media education

    Directory of Open Access Journals (Sweden)

    Gerhard TULODZIECKI

    2012-12-01

    Full Text Available In Germany, educational standards for key school subjects have been developed as a consequence of the results of international comparative studies like PISA. Subsequently, supporters of interdisciplinary fields such as media education have also started calling for goals in the form of competency models and standards. In this context a competency standard model for media education will be developed with regard to the discussion about media competence and media education. In doing so the development of a competency model and the formulation of standards is described consequently as a decision making process. In this process decisions have to be made on competence areas and competence aspects to structure the model, on criteria to differentiate certain levels of competence, on the number of competence levels, on the abstraction level of standard formulations and on the tasks to test the standards. It is shown that the discussion on media education as well as on competencies and standards provides different possibilities of structuring, emphasizing and designing a competence standard model. Against this background we describe and give reasons for our decisions and our competency standards model. At the same time our contribution is meant to initiate further developments, testing and discussion.

  13. Standard and non-standard weak interactions

    International Nuclear Information System (INIS)

    Leurer, M.

    1985-12-01

    This work consists of independent chapters, all deal with weak interactions. The first chapter deals with left-right symmetric theories. Two main versions of these theories are discussed and compared. In addition, the K - K-bar mixing term is analysed: it has been known for several years now that in a left-right symmetric model there are new contributions to the mixing of kaons. We show that in the most appealing left-right symmetric model - the new contributions add up constructively. Consequently, we may derive reliable bounds on the mass of the right-handed gauge boson and the average mass of the (unavoidable) physical Higgs scalars. We also show that the new contributions are proportional to a new CP violating phase. While all previous treatments of the K - K-bar system were limited to the minimal model, we are able to show that our results hold also in the general case of nonminimal models. The second chapter deals with the possibility that W and Z are composite. Three experimental tests are discussed: (i) Universality -if W is composite then its coupling to the fermions is expected to deviate from universality. Since such deviations were not yet seen -we derive a lower bound on the compositeness scale. (ii) Possible enhancement of the reaction p-bar+p→Z 0 +γ+any - we show that if Z 0 is composite then the cross section for the above process might be considerably enhanced and this effect can be measured at CERN and Fermilab.(iii) The eeγ events of the 1983 run in CERN - we show that in contradiction to suggestions made in several papers, these events may not be explained by a composite-Z decaying through a scalar. In the last chapter we discuss the quark mixing angles

  14. Validation of evaluated neutron standard cross sections

    International Nuclear Information System (INIS)

    Badikov, S.; Golashvili, T.

    2008-01-01

    Some steps of the validation and verification of the new version of the evaluated neutron standard cross sections were carried out. In particular: -) the evaluated covariance data was checked for physical consistency, -) energy-dependent evaluated cross-sections were tested in most important neutron benchmark field - 252 Cf spontaneous fission neutron field, -) a procedure of folding differential standard neutron data in group representation for preparation of specialized libraries of the neutron standards was verified. The results of the validation and verification of the neutron standards can be summarized as follows: a) the covariance data of the evaluated neutron standards is physically consistent since all the covariance matrices of the evaluated cross sections are positive definite, b) the 252 Cf spectrum averaged standard cross-sections are in agreement with the evaluated integral data (except for 197 Au(n,γ) reaction), c) a procedure of folding differential standard neutron data in group representation was tested, as a result a specialized library of neutron standards in the ABBN 28-group structure was prepared for use in reactor applications. (authors)

  15. Status of conversion of NE standards to national consensus standards

    International Nuclear Information System (INIS)

    Jennings, S.D.

    1990-06-01

    One major goal of the Nuclear Standards Program is to convert existing NE standards into national consensus standards (where possible). This means that an NE standard in the same subject area using the national consensus process. This report is a summary of the activities that have evolved to effect conversion of NE standards to national consensus standards, and the status of current conversion activities. In some cases, all requirements in an NE standard will not be incorporated into the published national consensus standard because these requirements may be considered too restrictive or too specific for broader application by the nuclear industry. If these requirements are considered necessary for nuclear reactor program applications, the program standard will be revised and issued as a supplement to the national consensus standard. The supplemental program standard will contain only those necessary requirements not reflected by the national consensus standard. Therefore, while complete conversion of program standards may not always be realized, the standards policy has been fully supported in attempting to make maximum use of the national consensus standard. 1 tab

  16. Quasi standard model physics

    International Nuclear Information System (INIS)

    Peccei, R.D.

    1986-01-01

    Possible small extensions of the standard model are considered, which are motivated by the strong CP problem and by the baryon asymmetry of the Universe. Phenomenological arguments are given which suggest that imposing a PQ symmetry to solve the strong CP problem is only tenable if the scale of the PQ breakdown is much above M W . Furthermore, an attempt is made to connect the scale of the PQ breakdown to that of the breakdown of lepton number. It is argued that in these theories the same intermediate scale may be responsible for the baryon number of the Universe, provided the Kuzmin Rubakov Shaposhnikov (B+L) erasing mechanism is operative. (orig.)

  17. Non-standard antennas

    CERN Document Server

    Le Chevalier, Francois; Staraj, Robert

    2013-01-01

    This book aims at describing the wide variety of new technologies and concepts of non-standard antenna systems - reconfigurable, integrated, terahertz, deformable, ultra-wideband, using metamaterials, or MEMS,  etc, and how they open the way to a wide range of applications, from personal security and communications to multifunction radars and towed sonars, or satellite navigation systems, with space-time diversity on transmit and receive. A reference book for designers  in this lively scientific community linking antenna experts and signal processing engineers.

  18. Hazard Communication Standard

    International Nuclear Information System (INIS)

    Sichak, S.

    1991-01-01

    The current rate of technological advances has brought with it an overwhelming increase in the usage of chemicals in the workplace and in the home. Coupled to this increase has been a heightened awareness in the potential for acute and chronic injuries attributable to chemical insults. The Hazard Communication Standard has been introduced with the desired goal of reducing workplace exposures to hazardous substances and thereby achieving a corresponding reduction in adverse health effects. It was created and proclaimed by the US Department of Labor and regulated by the Occupational Safety and Health Administration. 1 tab

  19. Standard-model bundles

    CERN Document Server

    Donagi, Ron; Pantev, Tony; Waldram, Dan; Donagi, Ron; Ovrut, Burt; Pantev, Tony; Waldram, Dan

    2002-01-01

    We describe a family of genus one fibered Calabi-Yau threefolds with fundamental group ${\\mathbb Z}/2$. On each Calabi-Yau $Z$ in the family we exhibit a positive dimensional family of Mumford stable bundles whose symmetry group is the Standard Model group $SU(3)\\times SU(2)\\times U(1)$ and which have $c_{3} = 6$. We also show that for each bundle $V$ in our family, $c_{2}(Z) - c_{2}(V)$ is the class of an effective curve on $Z$. These conditions ensure that $Z$ and $V$ can be used for a phenomenologically relevant compactification of Heterotic M-theory.

  20. Primary length standard adjustment

    Science.gov (United States)

    Ševčík, Robert; Guttenová, Jana

    2007-04-01

    This paper deals with problems and techniques connected with primary length standard adjusting, which includes disassembling of the device and by use of the secondary laser with collimated beam and diffraction laws successively reassembling of the laser. In the reassembling process the device was enhanced with substituting the thermal grease cooling of cold finger by copper socket cooler. This improved external cooling system enables more effective cooling of molecular iodine in the cell, which allows better pressure stability of iodine vapor and easier readjustment of the system.

  1. [Humanitarian action threatened by standardization].

    Science.gov (United States)

    Mamou, J

    2002-01-01

    The author analyses the new international context in which humanitarian action is being undertaken. He raises the problem caused by the diverging objectives of impartial, neutral humanitarianism and politically motivated actions that implement strategies of prevention and conflict resolution. He reviews the criticism that humanitarian has come under in recent years and that has resulted in establishment of codes of conduct. However he points out the threat that the concepts of control and "jurisdiction" over humanitarian action represent and analyzes discrepancies between minimal standards and universal principles. The article concludes with a presentation of an alternative solution based on the "Quality" platform being developed by several French NGOs.

  2. Radiation safety: New international standards

    International Nuclear Information System (INIS)

    Gonzalez, A.J.

    1994-01-01

    This article highlights an important result of this work for the international harmonization of radiation safety: specifically, it present an overview of the forthcoming International Basic Safety Standards for Protection Against Ionizing Radiation and for the Safety of Radiation Sources - the so-called BSS. They have been jointly developed by six organizations - the Food and Agriculture Organization of the United Nations (FAO), the International Atomic Energy Agency (IAEA), the International Labour Organization (ILO), the Nuclear Energy Agency of the Organization for Economic Co-operation and Development (NEA/OECD), the Pan American Health Organization (PAHO), and the World Health Organization (WHO)

  3. Math: Basic Skills Content Standards

    Science.gov (United States)

    CASAS - Comprehensive Adult Student Assessment Systems (NJ1), 2008

    2008-01-01

    This document presents content standards tables for math. [CASAS content standards tables are designed for educators at national, state and local levels to inform the alignment of content standards, instruction and assessment. The Content Standards along with the CASAS Competencies form the basis of the CASAS integrated assessment and curriculum…

  4. Repeated Interaction in Standard Setting

    NARCIS (Netherlands)

    Larouche, Pierre; Schütt, Florian

    2016-01-01

    As part of the standard-setting process, certain patents become essential. This may allow the owners of these standard-essential patents to hold up implementers of the standard, who can no longer turn to substitute technologies. However, many real-world standards evolve over time, with several

  5. European standards for composite construction

    NARCIS (Netherlands)

    Stark, J.W.B.

    2000-01-01

    The European Standards Organisation (CEN) has planned to develop a complete set of harmonized European building standards. This set includes standards for composite steel and concrete buildings and bridges. The Eurocodes, being the design standards, form part of this total system of European

  6. Emergency Management Standards and Schools

    Science.gov (United States)

    National Clearinghouse for Educational Facilities, 2009

    2009-01-01

    This publication discusses emergency management standards for school use and lists standards recommended by FEMA's National Incident Management System (NIMS). Schools are encouraged to review these standards carefully and to adopt, where applicable, those that meet their needs. The lists of standards, resources, and references contained herein…

  7. Latest LHCb results

    Directory of Open Access Journals (Sweden)

    Martinelli Maurizio

    2014-01-01

    Full Text Available The LHCb experiment is one of the major research projects at the Large Hadron Collider. Its acceptance and instrumentation is optimised to perform high-precision studies of flavour physics and particle production in a unique kinematic range at unprecedented collision energies. Using large data samples accumulated in the years 2010-2012, the LHCb collaboration has conducted a series of measurements providing a sensitive test of the Standard Model and strengthening our knowledge of flavour physics, QCD and electroweak processes. The status of the experiment and some of its recent results are presented here.

  8. XML Diagnostics Description Standard

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Varandas, C.; Lister, J.; Yonekawa, I.

    2006-01-01

    A standard for the self-description of fusion plasma diagnostics will be presented, based on the Extensible Markup Language (XML). The motivation is to maintain and organise the information on all the components of a laboratory experiment, from the hardware to the access security, to save time and money when problems arises. Since there is no existing standard to organise this kind of information, every Association stores and organises each experiment in different ways. This can lead to severe problems when the organisation schema is poorly documented or written in national languages. The exchange of scientists, researchers and engineers between laboratories is a common practice nowadays. Sometimes they have to install new diagnostics or to update existing ones and frequently they lose a great deal of time trying to understand the currently installed system. The most common problems are: no documentation available; the person who understands it has left; documentation written in the national language. Standardisation is the key to solving all the problems mentioned. From the commercial information on the diagnostic (component supplier; component price) to the hardware description (component specifications; drawings) to the operation of the equipment (finite state machines) through change control (who changed what and when) and internationalisation (information at least in the native language and in English), a common XML schema will be proposed. This paper will also discuss an extension of these ideas to the self-description of ITER plant systems, since the problems will be identical. (author)

  9. The standard model

    International Nuclear Information System (INIS)

    Marciano, W.J.

    1994-03-01

    In these lectures, my aim is to provide a survey of the standard model with emphasis on its renormalizability and electroweak radiative corrections. Since this is a school, I will try to be somewhat pedagogical by providing examples of loop calculations. In that way, I hope to illustrate some of the commonly employed tools of particle physics. With those goals in mind, I have organized my presentations as follows: In Section 2, renormalization is discussed from an applied perspective. The technique of dimensional regularization is described and used to define running couplings and masses. The utility of the renormalization group for computing leading logs is illustrated for the muon anomalous magnetic moment. In Section 3 electroweak radiative corrections are discussed. Standard model predictions are surveyed and used to constrain the top quark mass. The S, T, and U parameters are introduced and employed to probe for ''new physics''. The effect of Z' bosons on low energy phenomenology is described. In Section 4, a detailed illustration of electroweak radiative corrections is given for atomic parity violation. Finally, in Section 5, I conclude with an outlook for the future

  10. Standards for scrotal ultrasonography

    Directory of Open Access Journals (Sweden)

    Janusz F. Tyloch

    2016-12-01

    Full Text Available The paper presents a description of essential equipment requirements for scrotal ultrasonography, including current ultrasound techniques, as well as a review of the most common scrotal pathologies. Patient preparation for the examination as well as ultrasound methodology for the assessment of scrotal and inguinal canal structures are discussed. The standard for scrotal ultrasound examination includes a precise B-mode evaluation, including testicular volumetric assessment performed using automatic measurement options based on the formula of a rotating ellipsoid or three measurements perpendicular to one another. Also, criteria for morphological assessment of abnormalities within testicular or epididymal parenchyma, including a precise evaluation of lesion size, delineation, shape and vascular pattern obtained with Doppler US, have been proposed. Standard assessment further includes epididymal evaluation, including epididymal size in the case of enlargement. The paper additionally discusses the method of ultrasonographic examination and describes the most common pathologies occurring within scrotal structures, including a quantitative analysis of hydrocele and other abnormal fluid reservoirs. We have also presented criteria for the assessment of varicocele as well as color and spectral Doppler flows in scrotal pathologies. Furthermore, we have proposed key components of scrotal ultrasound documentation, so that the contained data could be used to establish appropriate diagnosis, allowing for both adequate clinical management and the reproducibility of subsequent US evaluations performed by either the same or a different examiner. The most common causes of diagnostic errors have also been discussed.

  11. Standards for scrotal ultrasonography

    Science.gov (United States)

    Tyloch, Janusz F.

    2016-01-01

    The paper presents a description of essential equipment requirements for scrotal ultrasonography, including current ultrasound techniques, as well as a review of the most common scrotal pathologies. Patient preparation for the examination as well as ultrasound methodology for the assessment of scrotal and inguinal canal structures are discussed. The standard for scrotal ultrasound examination includes a precise B-mode evaluation, including testicular volumetric assessment performed using automatic measurement options based on the formula of a rotating ellipsoid or three measurements perpendicular to one another. Also, criteria for morphological assessment of abnormalities within testicular or epididymal parenchyma, including a precise evaluation of lesion size, delineation, shape and vascular pattern obtained with Doppler US, have been proposed. Standard assessment further includes epididymal evaluation, including epididymal size in the case of enlargement. The paper additionally discusses the method of ultrasonographic examination and describes the most common pathologies occurring within scrotal structures, including a quantitative analysis of hydrocele and other abnormal fluid reservoirs. We have also presented criteria for the assessment of varicocele as well as color and spectral Doppler flows in scrotal pathologies. Furthermore, we have proposed key components of scrotal ultrasound documentation, so that the contained data could be used to establish appropriate diagnosis, allowing for both adequate clinical management and the reproducibility of subsequent US evaluations performed by either the same or a different examiner. The most common causes of diagnostic errors have also been discussed. PMID:28138410

  12. Fiscal 1997 report on the results of the international standardization R and D. Study on optimizing design/evaluation technology using quality engineering; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Hinshitsu kogaku ni yoru saitekika sekkei hyoka gijutsu ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    To take up methodology of quality engineering as ISO standards, the basic document was worked out which regulates general items for the method to evaluate the operation of various systems as function for proposal to ISO. A method is developed for evaluating the design quality by function and predicting/optimizing the quality of finished products. For the evaluation of slippage from ideal function, the SN ratio and Maharanobis`s distance are used. In the two basic working groups (WG), a document on general methods to evaluate function was made. To reinforce the basic document, WGs divided into five by content/business were set up. Each WG collected examples from the past, studied methods to evaluate function in each field, and recorded them in the document. Five experiments for each WG were conducted to verify effectiveness of the above-mentioned method to evaluate function recorded in the document. As a result, the draft to present to ISO was worked out since the experimental WGs proved the effectiveness of the method to evaluate function in each field. 85 refs., 147 figs., 185 tabs.

  13. Appliance Efficiency Standards and Price Discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Spurlock, Cecily Anna [Univ. of California, Berkeley, CA (United States)

    2013-05-08

    I explore the effects of two simultaneous changes in minimum energy efficiency and ENERGY STAR standards for clothes washers. Adapting the Mussa and Rosen (1978) and Ronnen (1991) second-degree price discrimination model, I demonstrate that clothes washer prices and menus adjusted to the new standards in patterns consistent with a market in which firms had been price discriminating. In particular, I show evidence of discontinuous price drops at the time the standards were imposed, driven largely by mid-low efficiency segments of the market. The price discrimination model predicts this result. On the other hand, in a perfectly competition market, prices should increase for these market segments. Additionally, new models proliferated in the highest efficiency market segment following the standard changes. Finally, I show that firms appeared to use different adaptation strategies at the two instances of the standards changing.

  14. Reading the New Standard ISA700

    Directory of Open Access Journals (Sweden)

    Daniel Botez

    2010-12-01

    Full Text Available Review of permanent professional standards is a requirement for professional bodies of professional accountants, resulting in broader processes of globalization and harmonization. A set of revised standards on financial audit engagement was published by IFAC in April 2009. International Standard on Auditing (ISA 700 "Forming an opinion and reporting on financial statements” is one of them. This standard deals with the auditor's responsibility to form an opinion on the financial statements and determine the form and content of the auditor's report issued following an audit of financial statements. Even if you do not have major changes, the revised standard contains several provisions that emphasize the important role of the auditor's report and more specifically defines its responsibility.

  15. Telemetry Standards, IRIG Standard 106-17. Chapter 10. Digital Recording Standard

    Science.gov (United States)

    2017-07-01

    formatting characters, representing the numeric date on which the file was created (e.g., BCS codes for the decimal digits 02092000...Telemetry Standards, IRIG Standard 106-17 Chapter 10, July 2017 CHAPTER 10 Digital Recording Standard Acronyms...10-v Chapter 10. Digital Recording Standard

  16. 76 FR 81295 - Cost Accounting Standards: Cost Accounting Standards 412 and 413-Cost Accounting Standards...

    Science.gov (United States)

    2011-12-27

    ... Federal Procurement Policy 48 CFR Part 9904 Cost Accounting Standards: Cost Accounting Standards 412 and 413--Cost Accounting Standards Pension Harmonization Rule; Final Rule #0;#0;Federal Register / Vol. 76... MANAGEMENT AND BUDGET Office of Federal Procurement Policy 48 CFR Part 9904 Cost Accounting Standards: Cost...

  17. 3G Standards

    DEFF Research Database (Denmark)

    Saugstrup, Dan; Henten, Anders

    2006-01-01

    angles – technology, markets and economy, policy and regulation, and other social aspects. Findings – The paper concludes that WCDMA will dominate the markets, but that there will be a co-existence of different solutions – also inside individual countries where more than one solution is implemented...... are the most decisive factors in the battle between the different standards – which roles do respectively technology path-dependence, network effects and strategic concerns play? Design/methodology/approach – The approach taken in the paper is to examine the different kinds of stakeholders – in this field......, first and foremost, equipment manufacturers, network operators, policy makers/administrators and end users; to analyze how such stakeholders are intervening in the different relevant steps – technology development, technology deployment and technology take-up – and to analyze these issues from different...

  18. Status of Standardization Projects

    Science.gov (United States)

    1993-12-31

    CR SC BE 5935 3972 P-C-596- CON [EE PWR GEN SPEC FOP ESE 5 F7 94’ 953 9z3 A CR VD: BE ES N PAGE NO. A - 51 5935-5935 RCS NO. DD-OR&E(AR)759...DR&E(AR)759 STANDARDIZATION PROJECTS REPORT - 1ST QTR FY 1994 PREPARING ACTIVITY LISTING PA AAPAA p BPP .A- G/ASA NC AC 21 RC G CSOL- Qý yqFyýFT7RL AL...T-83727/1 TRANSOLVER TYPE 11.9 85 ES HE 941 9E- 5A 4,R AS F7 N 5990 0425 02 MIL-T-83727/2 TRANSOLVER TYPE 11.8 85 ES HE 941 95: 951 A Aý AS BE N 5990

  19. Standardization of SPECT imaging

    International Nuclear Information System (INIS)

    Mishio, Kouji

    1989-01-01

    Though the use of instruments for SPECT imaging is prevailing, the SPECT images from the several instruments appears many differences in quality respectively. For the purpose of studying the cause of different image quality between several instruments, SPECT images of the same phantom were acquired and processed using 6 instruments in 5 institutes to compare. Up to now the quality of SPECT images was foundamentally dependent on the hardware, but factors of software, such as reconstruction algorithms and determinations of severl parameters seemed to have more important effect upon the image quality. The adoption of appropriate processing method after minimizing the imaging deterioration due to the hardware would make the difference of image quality minimum, and could make the standardization of SPECT imaging possible. (author)

  20. Government by standards

    DEFF Research Database (Denmark)

    Triantafillou, Peter

    2016-01-01

    Since 2009, all Danish hospitals have been subjected to a comprehensive, mandatory accreditation system, the so-called Danish Quality Model (DDKM), in order to assure the quality of hospital services. So far there is no evidence of DDKM’s positive effects on clinical outcome and it may even be co......, it is argued that the accreditation system is hard to refuse because it promises to increase the quality of hospital services and, more importantly, because the procedural standards espoused by DDKM work through the structured and accountable freedom of medical staff....... be contributing to accountability overload. This article seeks to provide an explanation for why hospital staff seems to accept, albeit grudgingly and partially, the imposition of a new, comprehensive accountability system with questionable clinical merits. Inspired by Michel Foucault’s analytics of government...