WorldWideScience

Sample records for standard cad tool

  1. PV-CAD: an integrated tool for designing PV facades; PV-CAD - Ein integriertes Werkzeug zur Auslegung von PV-Fassaden

    Energy Technology Data Exchange (ETDEWEB)

    Giese, H.; Viotto, M. [Inst. fuer Solare Energieversorgungstechnik (ISET) e.V., Kassel (Germany); Esser, M.; Pukrop, D. [Univ. Oldenburg (Germany). Abt. Energie- und Halbleiterforschung; Stellbogen, D. [Zentrum fuer Sonnenergie- und Wasserstoff-Forschung, Stuttgart (Germany)

    1997-12-31

    PV-CAD provides PV system planners with a practice-oriented tool for an efficient design of PV facades. Being compatible with the standard programmes of the architects` and electrical engineering sectors it can be used on already existing systems and allows the user to draw on previously acquired knowedge. Its open interfaces permit the integration of further design tools. PV CAD works under Microsoft Windows for which it has the necessary graphic user interface. Its compliance to PC standards opens up a wide range of applications and permits its use also on inexpensive computers. Thanks to its promotion by the Federal Ministry for Education, Science, Research, and Technology under the research project ``Computer programmes for the design of photovoltaic facades`` PV-CAD is available at a moderate price. PV-CAD permits an efficient planning of solar facades and therefore has the potential to stimulate the use of PV on buildings. (orig.) [Deutsch] Mit PV-CAD steht dem Anlagenplaner ein anwendungsorientiertes Werkzeug zur Verfuegung, das eine rationelle Auslegung von PV-Fassaden ermoeglicht. Die Kompatibilitaet zu Standardprogrammen aus dem Architektur- und Elektrosektor erlaubt die Nutzung bereits vorhandener Systeme und damit erworbener Kenntnisse. Offene Schnittstellen gestatten die Einbindung weiterer Entwurfswerkzeuge. PV-CAD arbeitet unter Microsoft-Windows und verfuegt ueber die entsprechende grafische Benutzerschnittstelle. Die Kompatibilitaet zum PC-Standard eroeffnet eine sehr breite Anwenderbasis und ermoeglicht den Einsatz des Programms auch auf preiswerten Rechnern. Aufgrund der Foerderung durch das Bundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie im Rahmen des Forschungsprojekts `Rechnerprogramm zur Auslegung von Photovoltaik-Fassaden` steht PV-CAD preiswert zur Verfuegung. PV-CAD ermoeglicht eine effiziente Planung von Solarfassaden und kann daher dem PV-Einsatz in Gebaeuden weitere Impulse geben. (orig.)

  2. A tool to convert CAD models for importation into Geant4

    Science.gov (United States)

    Vuosalo, C.; Carlsmith, D.; Dasu, S.; Palladino, K.; LUX-ZEPLIN Collaboration

    2017-10-01

    The engineering design of a particle detector is usually performed in a Computer Aided Design (CAD) program, and simulation of the detector’s performance can be done with a Geant4-based program. However, transferring the detector design from the CAD program to Geant4 can be laborious and error-prone. SW2GDML is a tool that reads a design in the popular SOLIDWORKS CAD program and outputs Geometry Description Markup Language (GDML), used by Geant4 for importing and exporting detector geometries. Other methods for outputting CAD designs are available, such as the STEP format, and tools exist to convert these formats into GDML. However, these conversion methods produce very large and unwieldy designs composed of tessellated solids that can reduce Geant4 performance. In contrast, SW2GDML produces compact, human-readable GDML that employs standard geometric shapes rather than tessellated solids. This paper will describe the development and current capabilities of SW2GDML and plans for its enhancement. The aim of this tool is to automate importation of detector engineering models into Geant4-based simulation programs to support rapid, iterative cycles of detector design, simulation, and optimization.

  3. Improved algorithms and advanced features of the CAD to MC conversion tool McCad

    International Nuclear Information System (INIS)

    Lu, L.; Fischer, U.; Pereslavtsev, P.

    2014-01-01

    Highlights: •The latest improvements of the McCad conversion approach including decomposition and void filling algorithms is presented. •An advanced interface for the materials editing and assignment has been developed and added to the McCAD GUI. •These improvements have been tested and successfully applied to DEMO and ITER NBI (Neutral Beam Injector) applications. •The performance of the CAD model conversion process is shown to be significantly improved. -- Abstract: McCad is a geometry conversion tool developed at KIT to enable the automatic bi-directional conversions of CAD models into the Monte Carlo (MC) geometries utilized for neutronics calculations (CAD to MC) and, reversed (MC to CAD), for visualization purposes. The paper presents the latest improvements of the conversion algorithms including improved decomposition, void filling and an advanced interface for the materials editing and assignment. The new implementations and features were tested on fusion neutronics applications to the DEMO and ITER NBI (Neutral Beam Injector) models. The results demonstrate greater stability and enhanced efficiency of McCad conversion process

  4. CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.

    Science.gov (United States)

    Foldyna, Borek; Szilveszter, Bálint; Scholtz, Jan-Erik; Banerji, Dahlia; Maurovich-Horvat, Pál; Hoffmann, Udo

    2018-04-01

    Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the presence, extent and composition of coronary atherosclerosis. The CAD-RADS classification is a comprehensive tool for summarising findings on a per-patient-basis dependent on the highest-grade coronary artery lesion, ranging from CAD-RADS 0 (absence of CAD) to CAD-RADS 5 (total occlusion of a coronary artery). In addition, it provides suggestions for clinical management for each classification, including further testing and therapeutic options. Despite some limitations, CAD-RADS may facilitate improved communication between imagers and patient caregivers. As such, CAD-RADS may enable a more efficient use of coronary CTA leading to more accurate utilisation of invasive coronary angiograms. Furthermore, widespread use of CAD-RADS may facilitate registry-based research of diagnostic and prognostic aspects of CTA. • CAD-RADS is a tool for standardising coronary CTA reports. • CAD-RADS includes clinical treatment recommendations based on CTA findings. • CAD-RADS has the potential to reduce variability of CTA reports.

  5. BombCAD - A new tool for bomb defense in nuclear facilities

    International Nuclear Information System (INIS)

    Massa, D.J.; Howard, J.W.; Sturm, S.R.

    1988-01-01

    This paper describes a new tool for analysis of the specific vulnerability of diverse facilites to bomb attack and for computer-aided-design (CAD) of siting, screening and hardening/softening aspects of comprehensive bomb defense programs. BombCAD combines the extensive architectural and engineering data base and graphics capabilities of modern architectural CAD systems with the bomb effects computational capability of the ''SECUREPLAN'' BOMB UTILITY. BombCAD permits architects/engineers, security professionals and facility managers to analytically estimate and graphically display facility vulnerability and changes (reductions) in vulnerability which result from the adoption of various bomb defense measures

  6. DESIGN OF A SUPERBIKE PADDOCK STAND USING CAD AND CAE TOOLS

    Directory of Open Access Journals (Sweden)

    M.H. Mohd Noh

    2012-06-01

    Full Text Available Two people are required to operate current superbike paddock stands in order to elevate the superbike. Lifting the superbike alone using the current design of paddock stand may be impractical and inconvenient for users. To overcome this limitation, a new design of a superbike paddock stand was conceived that could be operated by a single user. CAD and CAE tools using CATIA V5R18 software were utilised in designing this new stand. A 3D CAD model was developed and analysed through finite element analysis (FEA and a prototype fabricated for verification testing of the design. The use of CAD and CAE tools saved much time in the design work and gave the researchers and designers freedom in producing their own design. However, the most important aspect of this design study was to design a superbike paddock stand that is more practical and convenient for operation by a single user.

  7. TinkerCell: modular CAD tool for synthetic biology

    Science.gov (United States)

    Chandran, Deepak; Bergmann, Frank T; Sauro, Herbert M

    2009-01-01

    Background Synthetic biology brings together concepts and techniques from engineering and biology. In this field, computer-aided design (CAD) is necessary in order to bridge the gap between computational modeling and biological data. Using a CAD application, it would be possible to construct models using available biological "parts" and directly generate the DNA sequence that represents the model, thus increasing the efficiency of design and construction of synthetic networks. Results An application named TinkerCell has been developed in order to serve as a CAD tool for synthetic biology. TinkerCell is a visual modeling tool that supports a hierarchy of biological parts. Each part in this hierarchy consists of a set of attributes that define the part, such as sequence or rate constants. Models that are constructed using these parts can be analyzed using various third-party C and Python programs that are hosted by TinkerCell via an extensive C and Python application programming interface (API). TinkerCell supports the notion of a module, which are networks with interfaces. Such modules can be connected to each other, forming larger modular networks. TinkerCell is a free and open-source project under the Berkeley Software Distribution license. Downloads, documentation, and tutorials are available at . Conclusion An ideal CAD application for engineering biological systems would provide features such as: building and simulating networks, analyzing robustness of networks, and searching databases for components that meet the design criteria. At the current state of synthetic biology, there are no established methods for measuring robustness or identifying components that fit a design. The same is true for databases of biological parts. TinkerCell's flexible modeling framework allows it to cope with changes in the field. Such changes may involve the way parts are characterized or the way synthetic networks are modeled and analyzed computationally. TinkerCell can readily

  8. TinkerCell: modular CAD tool for synthetic biology

    Directory of Open Access Journals (Sweden)

    Bergmann Frank T

    2009-10-01

    Full Text Available Abstract Background Synthetic biology brings together concepts and techniques from engineering and biology. In this field, computer-aided design (CAD is necessary in order to bridge the gap between computational modeling and biological data. Using a CAD application, it would be possible to construct models using available biological "parts" and directly generate the DNA sequence that represents the model, thus increasing the efficiency of design and construction of synthetic networks. Results An application named TinkerCell has been developed in order to serve as a CAD tool for synthetic biology. TinkerCell is a visual modeling tool that supports a hierarchy of biological parts. Each part in this hierarchy consists of a set of attributes that define the part, such as sequence or rate constants. Models that are constructed using these parts can be analyzed using various third-party C and Python programs that are hosted by TinkerCell via an extensive C and Python application programming interface (API. TinkerCell supports the notion of a module, which are networks with interfaces. Such modules can be connected to each other, forming larger modular networks. TinkerCell is a free and open-source project under the Berkeley Software Distribution license. Downloads, documentation, and tutorials are available at http://www.tinkercell.com. Conclusion An ideal CAD application for engineering biological systems would provide features such as: building and simulating networks, analyzing robustness of networks, and searching databases for components that meet the design criteria. At the current state of synthetic biology, there are no established methods for measuring robustness or identifying components that fit a design. The same is true for databases of biological parts. TinkerCell's flexible modeling framework allows it to cope with changes in the field. Such changes may involve the way parts are characterized or the way synthetic networks are modeled

  9. CATO: a CAD tool for intelligent design of optical networks and interconnects

    Science.gov (United States)

    Chlamtac, Imrich; Ciesielski, Maciej; Fumagalli, Andrea F.; Ruszczyk, Chester; Wedzinga, Gosse

    1997-10-01

    Increasing communication speed requirements have created a great interest in very high speed optical and all-optical networks and interconnects. The design of these optical systems is a highly complex task, requiring the simultaneous optimization of various parts of the system, ranging from optical components' characteristics to access protocol techniques. Currently there are no computer aided design (CAD) tools on the market to support the interrelated design of all parts of optical communication systems, thus the designer has to rely on costly and time consuming testbed evaluations. The objective of the CATO (CAD tool for optical networks and interconnects) project is to develop a prototype of an intelligent CAD tool for the specification, design, simulation and optimization of optical communication networks. CATO allows the user to build an abstract, possible incomplete, model of the system, and determine its expected performance. Based on design constraints provided by the user, CATO will automatically complete an optimum design, using mathematical programming techniques, intelligent search methods and artificial intelligence (AI). Initial design and testing of a CATO prototype (CATO-1) has been completed recently. The objective was to prove the feasibility of combining AI techniques, simulation techniques, an optical device library and a graphical user interface into a flexible CAD tool for obtaining optimal communication network designs in terms of system cost and performance. CATO-1 is an experimental tool for designing packet-switching wavelength division multiplexing all-optical communication systems using a LAN/MAN ring topology as the underlying network. The two specific AI algorithms incorporated are simulated annealing and a genetic algorithm. CATO-1 finds the optimal number of transceivers for each network node, using an objective function that includes the cost of the devices and the overall system performance.

  10. CAD-guidelines

    International Nuclear Information System (INIS)

    Schlechtendahl, E.G.; Lang-Lendorff, G.

    1982-10-01

    The CAD-guidelines (CAD = Computer Aided Design) contain rules for programming, structuring and documentation of programs. The standard deals with the structure of CAD-programs, their components, the programming-methods, the language etc. It describes what documents and references are necessary for a CAD-program. In order to gain a broad application of CAD criteria like portability and completeness of the documentation for an effective maintenance are as important as a transparent way of producing CAD-software. (orig.) [de

  11. AutoCAD 2014 and AutoCAD LT 2014

    CERN Document Server

    Gladfelter, Donnie

    2013-01-01

    A step-by-step tutorial introduction to AutoCAD As the only book to teach AutoCAD using a continuous tutorial which allows you to follow along sequentially or jump in at any exercise by downloading the drawing files, this Autodesk Official Press book is ideal for the AutoCAD novice. Industry expert and AutoCAD guru Donnie Gladfelter walks you through the powerful features of AutoCAD, provides you with a solid foundation of the basics, and shares the latest industry standards and techniques. The hands-on tutorial project inspired by real-world workflows that runs throughout the book

  12. Learning Auto CAD 2004

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Gyeong Su; Song, Chun Dong; Park, Hyeong Jin; Kim, Yeong Min

    2004-02-15

    This book introduces basic knowledge of AutoCAD, practice method of command of AutoCAD like poly line, rotate, copy, break, trim, stretch, lengthen, chamfer, grips, extend, array polygon, spline, hatch, and image, writing letters, making library, application of design center and tool palette, drawing floor plan elevation, cross-sectional diagram, presentation materials, effective application of AutoCAD, and construction design using CAD POWER 2004.

  13. Learning Auto CAD 2004

    International Nuclear Information System (INIS)

    Shin, Gyeong Su; Song, Chun Dong; Park, Hyeong Jin; Kim, Yeong Min

    2004-02-01

    This book introduces basic knowledge of AutoCAD, practice method of command of AutoCAD like poly line, rotate, copy, break, trim, stretch, lengthen, chamfer, grips, extend, array polygon, spline, hatch, and image, writing letters, making library, application of design center and tool palette, drawing floor plan elevation, cross-sectional diagram, presentation materials, effective application of AutoCAD, and construction design using CAD POWER 2004.

  14. The application of springback compensation to the CAD geometries of forming tools: Milestone 2

    NARCIS (Netherlands)

    Lingbeek, R.A.

    2005-01-01

    For car body parts, generally a surface modeling CAD system is used. The geometry of the tools that are used for forming the parts is based directly on this description. To compensate for springback after forming, the tools have to be modified. This turns out to be a complicated and time consuming

  15. AutoCAD 2014 for dummies

    CERN Document Server

    Fane, Bill

    2013-01-01

    Find your way around AutoCAD 2014 with this full-color, For Dummies guide!Put away that pencil and paper and start putting the power of AutoCAD 2014 to work in your CAD projects and designs. From setting up your drawing environment to using text, dimensions, hatching, and more, this guide walks you through AutoCAD basics and provides you with a solid understanding of the latest CAD tools and techniques. You'll also benefit from the full-color illustrations that mirror exactly what you'll see on your AutoCAD 2014 screen and highlight the importance of AutoCAD's Mode

  16. Tool application CAD / CAM for design and construction of a prototype of plastic injection mold

    Directory of Open Access Journals (Sweden)

    Albert Miyer Suárez Castrillón

    2015-11-01

    Full Text Available The study, development and production of injection molds comes with the implementation of CAD and CAM tools available on the market; using these tools, a prototype injection mold for thermoplastic materials was designed and built, based on a mold is injection in the laboratory of the University of Pamplona, in which a couple of modifications were made in order to experiment with its design. The prototype was manufactured through a 3D scan of the original mold to provide the CAD / CAM files with the simulated 3D printing technique for performing an experimental study with the prototype for adjusting temperature and pressure sensors and for coatings metallic materials for use in the injection molding process.

  17. Assessing operating characteristics of CAD algorithms in the absence of a gold standard

    International Nuclear Information System (INIS)

    Roy Choudhury, Kingshuk; Paik, David S.; Yi, Chin A.; Napel, Sandy; Roos, Justus; Rubin, Geoffrey D.

    2010-01-01

    Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range of operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.

  18. AutoCAD 2010 For Dummies

    CERN Document Server

    Byrnes, David

    2009-01-01

    AutoCAD is the hot computer-aided design software known for both its powerful tools and its complexity. AutoCAD 2010 for Dummies is the bestselling guide that walks you through this complicated program so you can build complex 3D technical drawings, edit like a pro, enter new dimensions, and plot with style. AutoCAD 2010 for Dummies helps you navigate the program, use the AutoCAD Design Center, create a basic layout and work with dimension, and put your drawings on the Internet. You'll soon be setting up the AutoCAD environment, using the AutoCAD Ribbon, creating annotation and dimension drawi

  19. Machinability of CAD-CAM materials.

    Science.gov (United States)

    Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C

    2017-08-01

    Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. 3D CAD ON Qinshan CANDU project

    International Nuclear Information System (INIS)

    Goland, D.

    2000-01-01

    This paper briefly describe AECL's work in applying computer-aided engineering tools to the Qinshan CANDU project. The main thrust of this paper is to introduce the major CAD software tools and their use in civil design, process design and EI and C design. Other special software tools and non-CAD tools and their applications are also briefly introduced. (author)

  1. Easy Korean Auto CAD 14

    International Nuclear Information System (INIS)

    Lee, Jae Cheol

    1997-10-01

    This book introduces Auto CAD 14, which includes summary of basic things of Auto CAD 14, user interface for Auto CAD, basic drawing and advice, layer and set-up drawing, drawing with Auto CAD tools exactly, basic drawing of every thing, edit command, control of display, modeling and view ports of drawing space, various things drawing, writing letters, modification of floor plan, and check, block, X ref, lines and hatch, writing measurement, floor plan and OLE exchange of data, 3D floor plan, and rendering and presentation.

  2. Computer-aided detection (CAD) in mammography: Does it help the junior or the senior radiologist?

    International Nuclear Information System (INIS)

    Balleyguier, Corinne; Kinkel, Karen; Fermanian, Jacques; Malan, Sebastien; Djen, Germaine; Taourel, Patrice; Helenon, Olivier

    2005-01-01

    Objectives: To evaluate the impact of a computer-aided detection (CAD) system on the ability of a junior and senior radiologist to detect breast cancers on mammograms, and to determine the potential of CAD as a teaching tool in mammography. Methods: Hundred biopsy-proven cancers and 100 normal mammograms were randomly analyzed by a CAD system. The sensitivity (Se) and specificity (Sp) of the CAD system were calculated. In the second phase, to simulate daily practice, 110 mammograms (97 normal or with benign lesions, and 13 cancers) were examined independently by a junior and a senior radiologist, with and without CAD. Interpretations were standardized according to BI-RADS classification. Sensitivity, Specificity, positive and negative predictive values (PPV, NPV) were calculated for each session. Results: For the senior radiologist, Se slightly improved from 76.9 to 84.6% after CAD analysis (NS) (one case of clustered microcalcifications case overlooked by the senior radiologist was detected by CAD). Sp, PPV and PNV did not change significantly. For the junior radiologist, Se improved from 61.9 to 84.6% (significant change). Three cancers overlooked by the junior radiologist were detected by CAD. Sp was unchanged. Conclusion: CAD mammography proved more useful for the junior than for the senior radiologist, improving sensitivity. The CAD system may represent a useful educational tool for mammography

  3. Preparation of CAD infrastructure for ITER procurement packages allocated to Korea

    International Nuclear Information System (INIS)

    Kim, G.H.; Hwang, H.S.; Choi, J.H.; Lee, H.G.; Thomas, E.; Redon, F.; Wilhelm, B.

    2013-01-01

    Highlights: ► It is necessary to use the same CAD platform between project partners for efficient design collaboration. ► Several unexpected problems were found during preparation of the CAD infrastructure. ► The problems have resulted in a waste of time and cost. ► The approach using the same configurations is effective to avoid IT-related problems. ► The design activities are steadily being performed on the prepared ITER CAD platform. -- Abstract: It is necessary to use the same CAD platform for standardization and efficient design collaboration between project partners. ITER has selected CATIA with ENOVIA as the primary CAD and integration tool. During the preparation of the CAD infrastructure, there were several difficulties with respect to information technology (IT). ITER design is classified as mechanical and plant. The procurement arrangement is divided into three types; functional specification, detailed design, and build to print. Therefore, it is important to prepare the suitable prerequisites according to the design type, and to comply with CAD methodologies to avoid trial and error. This paper presents how to overcome the difficulties and how to perform the CAD activities for ITER Korea procurement packages including important matters on a CAD infrastructure in a big project

  4. AutoCAD 2014 essentials

    CERN Document Server

    Onstott, Scott

    2013-01-01

    Learn crucial AutoCAD tools and techniques with this Autodesk Official Press Book Quickly become productive using AutoCAD 2014 and AutoCAD LT 2014 with this full color Autodesk Official Press guide. This unique learning resource features concise, straightforward explanations and real-world, hands-on exercises and tutorials. Following a quick discussion of concepts and goals, each chapter moves on to an approachable hands-on exercise designed to reinforce real-world tactics and techniques. Compelling, full-color screenshots illustrate tutorial steps, and chapters conclude with relat

  5. Development of 3D CAD system as a design tool for PEACER development

    International Nuclear Information System (INIS)

    Jeong, Kwang Jin; Lee, Hyoung Won; Jeong, Seung Ho; Shin, Jong Gye; Hwang, Il Soon

    2003-01-01

    In an effort to resolve generic concerns with current power reactors, PEACER has been developed as a proliferation-resistant waste transmutation reactor based on a unique combination of technologies of a proven fast reactor and the heavy liquid metal coolant. In order to develop engineering design and visualize its performance, a three-dimensional computer aided design (3D CAD) method has been devised. Based on conceptual design, system, structure and components of PEACER are defined. Using results from finite element stress analyzer, computational fluid dynamics tool, nuclear analysis tool, etc, 3D visualization is achieved on the geometric construct based on CATIA. A 3D visualization environment is utilized not only to overcome the integration complexity but also to manipulate data flow such as meshing information used in analysis codes. The 3D CAD system in this paper includes an open language, Virtual Reality Modeling Language (VRML), to deliver analyses results on 3D objects, interactively. Such modeling environment is expected to improve the efficiency of designing the conceptual reactor, PEACER, reducing time and cost. Results of 3D design and stress analysis simulation will be presented as an example case. (author)

  6. Development of 3D CAD system as a design tool for PEACER development

    International Nuclear Information System (INIS)

    Lee, H. W.; Jung, K. J.; Jung, S. H.; Hwang, I. S.

    2003-01-01

    In an effort to resolve generic concerns with current power reactors, PEACER[1] has been developed as a proliferation-resistant waste transmutation reactor based on a unique combination of technologies of a prove a fast reactor and the heavy liquid metal coolant. In order to develop engineering design and visualize its performance, a three dimensional computer aided design (3D CAD) method has been devised. Based on conceptual design, system, structure and components of PEACER are defined. Using resuIts from finite element stress analyzer, computational fluid dynamics tool, nuclear analysis tool, etc, 3D visualization is achieved on the geometric construct based on CATIA[3]. A 3D visualization environment is utilized not only to overcome the integration complexity but also to manipulate data flow such as meshing information used in analysis codes. The 3D CAD system in this paper includes an open language, Virtual Reality Modeling Language (VRML)[4,5], to deliver analyses results on 3D objects, interactively. Such modeling environment is expected to improve the efficiency of designing the conceptual reactor, PEACER, reducing time and cost. ResuIts of 3D design and system performance simulation will be presented

  7. Front panel engineering with CAD simulation tool

    Science.gov (United States)

    Delacour, Jacques; Ungar, Serge; Mathieu, Gilles; Hasna, Guenther; Martinez, Pascal; Roche, Jean-Christophe

    1999-04-01

    THe progress made recently in display technology covers many fields of application. The specification of radiance, colorimetry and lighting efficiency creates some new challenges for designers. Photometric design is limited by the capability of correctly predicting the result of a lighting system, to save on the costs and time taken to build multiple prototypes or bread board benches. The second step of the research carried out by company OPTIS is to propose an optimization method to be applied to the lighting system, developed in the software SPEOS. The main features of the tool requires include the CAD interface, to enable fast and efficient transfer between mechanical and light design software, the source modeling, the light transfer model and an optimization tool. The CAD interface is mainly a prototype of transfer, which is not the subjects here. Photometric simulation is efficiently achieved by using the measured source encoding and a simulation by the Monte Carlo method. Today, the advantages and the limitations of the Monte Carlo method are well known. The noise reduction requires a long calculation time, which increases with the complexity of the display panel. A successful optimization is difficult to achieve, due to the long calculation time required for each optimization pass including a Monte Carlo simulation. The problem was initially defined as an engineering method of study. The experience shows that good understanding and mastering of the phenomenon of light transfer is limited by the complexity of non sequential propagation. The engineer must call for the help of a simulation and optimization tool. The main point needed to be able to perform an efficient optimization is a quick method for simulating light transfer. Much work has been done in this area and some interesting results can be observed. It must be said that the Monte Carlo method wastes time calculating some results and information which are not required for the needs of the simulation

  8. AutoCAD 2012 and AutoCAD LT 2012 No Experience Required

    CERN Document Server

    Gladfelter, Donnie

    2011-01-01

    The perfect step-by-step introduction to Autodesk's powerful architectural design software With this essential guide, you'll learn how to plan, develop, document, and present a complete AutoCAD project by building a summer cabin from start to finish. You can follow each step sequentially or jump in at any point by downloading the drawing files from the book's companion web site. You'll also master all essential AutoCAD features, get a thorough grounding in the basics, learn the very latest industry standards and techniques, and quickly become productive with AutoCAD 2012.Features concise expla

  9. Research on AutoCAD secondary development and function expansion based on VBA technology

    Science.gov (United States)

    Zhang, Runmei; Gu, Yehuan

    2017-06-01

    AutoCAD is the most widely used drawing tool among the similar design drawing products. In the process of drawing different types of design drawings of the same product, there are a lot of repetitive and single work contents. The traditional manual method uses a drawing software AutoCAD drawing graphics with low efficiency, high error rate and high input cost shortcomings and many more. In order to solve these problems, the design of the parametric drawing system of the hot-rolled I-beam (steel beam) cross-section is completed by using the VBA secondary development tool and the Access database software with large-capacity storage data, and the analysis of the functional extension of the plane drawing and the parametric drawing design in this paper. For the secondary development of AutoCAD functions, the system drawing work will be simplified and work efficiency also has been greatly improved. This introduction of parametric design of AutoCAD drawing system to promote the industrial mass production and related industries economic growth rate similar to the standard I-beam hot-rolled products.

  10. Quantitative assessment of multiple sclerosis lesion load using CAD and expert input

    Science.gov (United States)

    Gertych, Arkadiusz; Wong, Alexis; Sangnil, Alan; Liu, Brent J.

    2008-03-01

    Multiple sclerosis (MS) is a frequently encountered neurological disease with a progressive but variable course affecting the central nervous system. Outline-based lesion quantification in the assessment of lesion load (LL) performed on magnetic resonance (MR) images is clinically useful and provides information about the development and change reflecting overall disease burden. Methods of LL assessment that rely on human input are tedious, have higher intra- and inter-observer variability and are more time-consuming than computerized automatic (CAD) techniques. At present it seems that methods based on human lesion identification preceded by non-interactive outlining by CAD are the best LL quantification strategies. We have developed a CAD that automatically quantifies MS lesions, displays 3-D lesion map and appends radiological findings to original images according to current DICOM standard. CAD is also capable to display and track changes and make comparison between patient's separate MRI studies to determine disease progression. The findings are exported to a separate imaging tool for review and final approval by expert. Capturing and standardized archiving of manual contours is also implemented. Similarity coefficients calculated from quantities of LL in collected exams show a good correlation of CAD-derived results vs. those incorporated as expert's reading. Combining the CAD approach with an expert interaction may impact to the diagnostic work-up of MS patients because of improved reproducibility in LL assessment and reduced time for single MR or comparative exams reading. Inclusion of CAD-generated outlines as DICOM-compliant overlays into the image data can serve as a better reference in MS progression tracking.

  11. Teach CAD and Measuring Skills through Reverse Engineering

    Science.gov (United States)

    Board, Keith

    2012-01-01

    This article describes a reverse engineering activity that gives students hands-on, minds-on experience with measuring tools, machine parts, and CAD. The author developed this activity to give students an abundance of practical experience with measuring tools. Equally important, it provides a good interface between the virtual world of CAD 3D…

  12. Interoperability of CAD Standards and Robotics in CIME

    DEFF Research Database (Denmark)

    Sørensen, Torben

    The research presented in this dissertation concerns the identification of problems and provision of solutions for increasing the degree of interoperability between CAD, CACSD (Computer Aided Control Systems Design) and CAR (Computer Aided Robotics) in Computer Integrated Manufacturing and Engine......The research presented in this dissertation concerns the identification of problems and provision of solutions for increasing the degree of interoperability between CAD, CACSD (Computer Aided Control Systems Design) and CAR (Computer Aided Robotics) in Computer Integrated Manufacturing......· The development of a STEP based interface for general control system data and functions, especially related to robot motion control for interoperability of CAD, CACSD, and CAR systems for the extension of the inter-system communication capabilities beyond the stage achieved up to now.This interface development...... comprehends the following work:· The definition of the concepts of 'information' and 'information model', and the selection of a proper information modeling methodology within the STEP methodologies.· The elaboration of a general function model of a generic robot motion controller in IDEF0 for interface...

  13. The Coronary Artery Disease-Reporting and Data System (CAD-RADS): Prognostic and Clinical Implications Associated With Standardized Coronary Computed Tomography Angiography Reporting.

    Science.gov (United States)

    Xie, Joe X; Cury, Ricardo C; Leipsic, Jonathon; Crim, Matthew T; Berman, Daniel S; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Ó Hartaigh, Bríain; Callister, Tracy Q; Marques, Hugo; Rubinshtein, Ronen; Al-Mallah, Mouaz H; Andreini, Daniele; Pontone, Gianluca; Cademartiri, Filippo; Maffei, Erica; Chinnaiyan, Kavitha; Raff, Gilbert; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Dunning, Allison; DeLago, Augustin; Kim, Yong-Jin; Kaufmann, Philipp A; Villines, Todd C; Chow, Benjamin J W; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Jones, Erica; Min, James K; Shaw, Leslee J

    2018-01-01

    This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care. Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA. In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed. Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p data, 57% of CAD-RADS 3 patients who received 30-day ICA were either asymptomatic or not receiving antianginal therapy at baseline, whereas only 32% had angina and were receiving medical therapy. CAD-RADS effectively identified patients at risk for adverse events. Frequent ICA use was observed among patients without severe CAD, many of whom were asymptomatic or not taking antianginal drugs. Incorporating CAD-RADS into coronary CTA reports may provide a novel opportunity to promote evidence-based care post-coronary CTA. Copyright © 2018 American College of Cardiology

  14. AutoCAD platform customization autolisp

    CERN Document Server

    Ambrosius, Lee

    2014-01-01

    Customize and personalize programs built on the AutoCAD platform AutoLISP is the key to unlocking the secrets of a more streamlined experience using industry leading software programs like AutoCAD, Civil 3D, Plant 3D, and more. AutoCAD Platform Customization: AutoLISP provides real-world examples that show you how to do everything from modifying graphical objects and reading and setting system variables to communicating with external programs. It also features a resources appendix and downloadable datasets and customization examples-tools that ensure swift and easy adoption. Find out how to r

  15. Structural design by CAD system

    International Nuclear Information System (INIS)

    Kim, Jhin Wung; Shim, Jae Ku; Kim, Sun Hoon; Kim, Dae Hong; Lee, Kyung Jin; Choi, Kyu Sup; Choi, In Kil; Lee, Dong Yong

    1988-12-01

    CAD systems are now widely used for the design of many engineering problems involving static, dynamic and thermal stress analyses of structures. In order to apply CAD systems to the structural analysis and design, the function of hardwares and softwares necessary for the CAD systems must be understood. The purpose of this study is to introduce the basic elements that are indispensible in the application of CAD systems to the analysis and design of structures and to give a thorough understanding of CAD systems to design engineers, so as to participate in the further technological developments of CAD systems. Due to the complexity and variety of the shape and size of the nowa-days structures, the need of new design technologies is growing for more efficient, accurate and economical design of structures. The application of CAD systems to structural engineering fields enables to improve structural engineering analysis and design technologies and also to obtain the standardization of the design process. An active introduction of rapidly developing CAD technologies will contribute to analyzing and designing structures more efficiently and reliably. Based on this report of the current status of the application of CAD systems to the structural analysis and design, the next goal is to develop the expert system which enables to perform the design of structures by CAD systems from the preliminary conceptual design to the final detail drawings automatically. (Author)

  16. Microleakage of composite crowns luted on CAD/CAM-milled human molars: a new method for standardized in vitro tests.

    Science.gov (United States)

    Schlenz, Maximiliane Amelie; Schmidt, Alexander; Rehmann, Peter; Niem, Thomas; Wöstmann, Bernd

    2018-04-24

    To investigate debonding of full crowns made of CAD/CAM composites, CAD/CAM technology was applied to manufacture standardized test abutments to increase the reproducibility of human teeth used in in vitro studies. A virtual test abutment and the corresponding virtual crown were designed and two STL data sets were generated. Sixty-four human third molars and CAD/CAM blocks were milled using a CNC machine. Crowns of four different composite blocks (Lava Ultimate (LU), Brilliant Crios (BC), Cerasmart (CS), Experimental (EX)) were adhesively bonded with their corresponding luting system (LU: Scotchbond Universal/RelyX Ultimate; BC: One Coat 7 Universal/DuoCem; CS: G-PremioBond/G-Cem LinkForce; EX: Experimental-Bond/Experimental-Luting-Cement). Half of the specimens were chemical-cured (CC) and the others were light-cured (LC). Afterwards, specimens were artificially aged in a chewing simulator (WL-tec, 1 million cycles, 50-500 N, 2 Hz, 37 °C). Finally, a dye penetration test was used to detect debonding. For inspection, the specimens were sliced, and penetration depth was measured with a digital microscope. Data were analyzed with the Mann-Whitney U test. No cases of total debonding were observed after cyclic loading. However, the LC specimens showed a significantly lower amount of leakage than the CC ones (p CAD/CAM technology in highly standardized test abutments for in vitro testing. For CAD/CAM composites, light curing should be performed. The success of a restoration depends on the long-term sealing ability of the luting materials, which avoids debonding along with microleakage. For CAD/CAM composites, separate light curing of the adhesive and luting composite is highly recommended.

  17. Customizing CAD system and its application for engineering design

    International Nuclear Information System (INIS)

    Shin, Jeong Ho; Kwak, Byung Man

    2003-01-01

    The computer is an important tool to design an engineering system and CAD systems are widely used for various design practice. To meet the market requirements, the old mass production system is being changed into the mass customization system. As for CAD systems, it is increasingly required to extend, automate, and customize a wide range of functionality. This article describes the state-of-the-art of the principal technologies for customizing CAD systems. And we have implemented an application that enables the parametric design by directly inputting numerical values of parameters for a CAD model. Based on this application, we have developed another system that makes it possible sharing of part family data between SolidEdge and Pro/Engineer. Through customization of CAD systems, it is possible to improve the product quality using external knowledge-based systems or to integrate with external system such as CAE tools. This paper can be a guide for engineering designers who want to customize CAD systems

  18. Investigating the Impact of Using a CAD Simulation Tool on Students' Learning of Design Thinking

    Science.gov (United States)

    Taleyarkhan, Manaz; Dasgupta, Chandan; Garcia, John Mendoza; Magana, Alejandra J.

    2018-02-01

    Engineering design thinking is hard to teach and still harder to learn by novices primarily due to the undetermined nature of engineering problems that often results in multiple solutions. In this paper, we investigate the effect of teaching engineering design thinking to freshmen students by using a computer-aided Design (CAD) simulation software. We present a framework for characterizing different levels of engineering design thinking displayed by students who interacted with the CAD simulation software in the context of a collaborative assignment. This framework describes the presence of four levels of engineering design thinking—beginning designer, adept beginning designer, informed designer, adept informed designer. We present the characteristics associated with each of these four levels as they pertain to four engineering design strategies that students pursued in this study—understanding the design challenge, building knowledge, weighing options and making tradeoffs, and reflecting on the process. Students demonstrated significant improvements in two strategies—understanding the design challenge and building knowledge. We discuss the affordances of the CAD simulation tool along with the learning environment that potentially helped students move towards Adept informed designers while pursuing these design strategies.

  19. Or CAD 9.1

    International Nuclear Information System (INIS)

    Lee, Seung Mu

    2000-02-01

    This book gives descriptions of Or CAD 9.1 with before drawing plan such as gaining Or CAD Demo CD, capture tools, making new design file, drawing structure, and setting design template, Drawings like making new drawing, finding parts, drawing lines, connecting line among the pages, and connecting parts using drawing structure, unstable multivibrator circle such as management of design file, power and ground connection, utility, beginning layout, single drawing, flat drawing, latch circuit, making a library, making a footprint, smart route and flash window.

  20. Computer-aided detection (CAD) and assessment of malignant lesions in the liver and lung using a novel PET/CT software tool. Initial results

    International Nuclear Information System (INIS)

    Hahn, Steffen; Heusner, T.; Forsting, M.; Antoch, G.; Zhou, X.; Zhan, Y.; Peng, Z.; Hamami, M.; Bockisch, A.

    2010-01-01

    Purpose: To determine the feasibility of a PET/CT software tool (PET computer-aided detection: PET-CAD) for automated detection and assessment of pulmonary and hepatic lesions. Materials and Methods: 20 consecutive patients with colorectal liver metastases and 20 consecutive patients suffering from non-small cell lung cancer (NSCLC) were examined with FDG-PET/CT. In a first step the maximum standardized uptake values (SUV max ) of non-tumorous liver and lung tissues were determined manually. This value was used as a threshold value for software-based lesion detection. The number of lesions detected, their SUV max , and their sizes in the x, y, and z-planes, as automatically provided by PET-CAD, were compared to visual lesion detection and manual measurements on CT. Results: The sensitivity for automated detection was 96% (86-99%) for colorectal liver metastases and 90% (70-99%) for lung lesions. The positive predictive value was 80% for liver and 68% for lung lesions. The mean SUV max of all lung lesions was 9.3 and 8.8 for the liver lesions. When assessed by PET-CAD, the mean lesion sizes for liver lesions in the x, y, and z-planes were 4.3 cm, 4.6 cm, and 4.2 cm compared to 3.5 cm, 3.8 cm, and 3.6 cm for manual measurements. The mean lesion sizes of lung lesions were 7.4 cm, 7.7 cm, and 8.4 cm in the x, y, and z-planes when assessed by PET-CAD compared to 5.8 cm, 6.1 cm, and 7.1 cm when measured manually. Using manual assessment, the lesion sizes were significantly smaller in all planes (p < 0.005). Conclusion: Software tools for automated lesion detection and assessment are expected to improve the clinical PET/CT workflow. Before implementation in the clinical routine, further improvements to the measurement accuracy are required. (orig.)

  1. Application of Auto CAD

    International Nuclear Information System (INIS)

    Park, Yong Un; Kim, Geun Ho

    1989-05-01

    This book has introduction to use this book and explanation of application on Auto CAD, which includes, sub directories, batch files, robot wrist, design of standard paper, title block, robort weld room, robert wrist joint, PC board, plant sym, electro, PID, machines, robots, bubbles, plant, schema, Pid, plant assembly, robots, dim plant, PL-ASSM, plotting line weight control, symbol drawing joint, Auto CAD using script file, set up of workout · MNU, workout MNU, ACAD, LSP and workout · MNU.

  2. Structured reporting platform improves CAD-RADS assessment.

    Science.gov (United States)

    Szilveszter, Bálint; Kolossváry, Márton; Karády, Júlia; Jermendy, Ádám L; Károlyi, Mihály; Panajotu, Alexisz; Bagyura, Zsolt; Vecsey-Nagy, Milán; Cury, Ricardo C; Leipsic, Jonathon A; Merkely, Béla; Maurovich-Horvat, Pál

    2017-11-01

    Structured reporting in cardiac imaging is strongly encouraged to improve quality through consistency. The Coronary Artery Disease - Reporting and Data System (CAD-RADS) was recently introduced to facilitate interdisciplinary communication of coronary CT angiography (CTA) results. We aimed to assess the agreement between manual and automated CAD-RADS classification using a structured reporting platform. Five readers prospectively interpreted 500 coronary CT angiographies using a structured reporting platform that automatically calculates the CAD-RADS score based on stenosis and plaque parameters manually entered by the reader. In addition, all readers manually assessed CAD-RADS blinded to the automatically derived results, which was used as the reference standard. We evaluated factors influencing reader performance including CAD-RADS training, clinical load, time of the day and level of expertise. Total agreement between manual and automated classification was 80.2%. Agreement in stenosis categories was 86.7%, whereas the agreement in modifiers was 95.8% for "N", 96.8% for "S", 95.6% for "V" and 99.4% for "G". Agreement for V improved after CAD-RADS training (p = 0.047). Time of the day and clinical load did not influence reader performance (p > 0.05 both). Less experienced readers had a higher total agreement as compared to more experienced readers (87.0% vs 78.0%, respectively; p = 0.011). Even though automated CAD-RADS classification uses data filled in by the readers, it outperforms manual classification by preventing human errors. Structured reporting platforms with automated calculation of the CAD-RADS score might improve data quality and support standardization of clinical decision making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  3. An Instructional Method for the AutoCAD Modeling Environment.

    Science.gov (United States)

    Mohler, James L.

    1997-01-01

    Presents a command organizer for AutoCAD to aid new uses in operating within the 3-D modeling environment. Addresses analyzing the problem, visualization skills, nonlinear tools, a static view of a dynamic model, the AutoCAD organizer, environment attributes, and control of the environment. Contains 11 references. (JRH)

  4. Optimized FPGA Implementation of the Thyroid Hormone Secretion Mechanism Using CAD Tools.

    Science.gov (United States)

    Alghazo, Jaafar M

    2017-02-01

    The goal of this paper is to implement the secretion mechanism of the Thyroid Hormone (TH) based on bio-mathematical differential eqs. (DE) on an FPGA chip. Hardware Descriptive Language (HDL) is used to develop a behavioral model of the mechanism derived from the DE. The Thyroid Hormone secretion mechanism is simulated with the interaction of the related stimulating and inhibiting hormones. Synthesis of the simulation is done with the aid of CAD tools and downloaded on a Field Programmable Gate Arrays (FPGAs) Chip. The chip output shows identical behavior to that of the designed algorithm through simulation. It is concluded that the chip mimics the Thyroid Hormone secretion mechanism. The chip, operating in real-time, is computer-independent stand-alone system.

  5. AutoCAD

    DEFF Research Database (Denmark)

    Jensen, Henrik

    1998-01-01

    I 1998 var AutoCAD Arkitektskolens basale CAD-tilbud til de studerende. Kursets vægt ligger på konstruktion og strukturering af 3d-modeller og med udgangspunkt i dette, 2d-tegning. Kurset er opbygget over CAD Clasic skabelonen (se min forskning). Kompendiet kan bruges til selvstudium.......I 1998 var AutoCAD Arkitektskolens basale CAD-tilbud til de studerende. Kursets vægt ligger på konstruktion og strukturering af 3d-modeller og med udgangspunkt i dette, 2d-tegning. Kurset er opbygget over CAD Clasic skabelonen (se min forskning). Kompendiet kan bruges til selvstudium....

  6. Computer-aided diagnosis (CAD) of subsolid nodules: Evaluation of a commercial CAD system

    International Nuclear Information System (INIS)

    Benzakoun, Joseph; Bommart, Sébastien; Coste, Joël; Chassagnon, Guillaume; Lederlin, Mathieu; Boussouar, Samia

    2016-01-01

    Highlights: • CAD sensitivity is still limited for automated detection of subsolid nodules. • CAD detection rate is higher for part-solid than for pure ground-glass nodules. • Part-solid nodule detection is not better for nodules with larger solid component. - Abstract: Objectives: To evaluate the performance of a commercially available CAD system for automated detection and measurement of subsolid nodules. Materials and methods: The CAD system was tested on 50 pure ground-glass and 50 part-solid nodules (median diameter: 17 mm) previously found on standard-dose CT scans in 100 different patients. True nodule detection and the total number of CAD marks were evaluated at different sensitivity settings. The influence of nodule and CT acquisition characteristics was analyzed with logistic regression. Software and manually measured diameters were compared with Spearman and Bland-Altman methods. Results: With sensitivity adjusted for 3-mm nodule detection, 50/100 (50%) subsolid nodules were detected, at the average cost of 17 CAD marks per CT. These figures were respectively 26/100 (26%) and 2 at the 5-mm setting. At the highest sensitivity setting (2-mm nodule detection), the average number of CAD marks per CT was 41 but the nodule detection rate only increased to 54%. Part–solid nodules were better detected than pure ground glass nodules: 36/50 (72%) versus 14/50 (28%) at the 3-mm setting (p < 0.0001), with no influence of the solid component size. Except for the type (i.e. part solid or pure ground glass), no other nodule characteristic influenced the detection rate. High-quality segmentation was obtained for 79 nodules, which for automated measurements correlated well with manual measurements (rho = 0.90[0.84–0.93]). All part-solid nodules had software-measured attenuation values above −671 Hounsfield units (HU). Conclusion: The detection rate of subsolid nodules by this CAD system was insufficient, but high-quality segmentation was obtained in 79% of

  7. Computer-aided diagnosis (CAD) of subsolid nodules: Evaluation of a commercial CAD system

    Energy Technology Data Exchange (ETDEWEB)

    Benzakoun, Joseph, E-mail: benzakoun.joseph@gmail.com [Hôpital Hôtel-Dieu, 1 parvis Notre-Dame, 75004 Paris (France); Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Bommart, Sébastien, E-mail: s-bommart@chu-montpellier.fr [CHU de Montpellier, 191 avenue du Doyen Gaston Giraud, 34000 Montpellier (France); INSERM U 1046, 371 avenue du Doyen G. Giraud, 34000 Montpellier (France); Coste, Joël, E-mail: joel.coste@htd.aphp.fr [Hôpital Hôtel-Dieu, 1 parvis Notre-Dame, 75004 Paris (France); Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Chassagnon, Guillaume, E-mail: gchassagnon@gmail.com [Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Hôpital Cochin, Radiologie, 27 rue du Faubourg Saint Jacques, 75014 Paris (France); Lederlin, Mathieu, E-mail: mathieu.lederlin@chu-rennes.fr [CHU de Rennes, Radiologie, 2 Rue Henri le Guilloux, 35000 Rennes (France); Université de Rennes 1, 9 Rue Jean Macé, 35000 Rennes (France); Boussouar, Samia, E-mail: samiaboussouar@gmail.com [Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Hôpital Européen Georges Pompidou, 20 Rue Leblanc, 75015 Paris (France); and others

    2016-10-15

    Highlights: • CAD sensitivity is still limited for automated detection of subsolid nodules. • CAD detection rate is higher for part-solid than for pure ground-glass nodules. • Part-solid nodule detection is not better for nodules with larger solid component. - Abstract: Objectives: To evaluate the performance of a commercially available CAD system for automated detection and measurement of subsolid nodules. Materials and methods: The CAD system was tested on 50 pure ground-glass and 50 part-solid nodules (median diameter: 17 mm) previously found on standard-dose CT scans in 100 different patients. True nodule detection and the total number of CAD marks were evaluated at different sensitivity settings. The influence of nodule and CT acquisition characteristics was analyzed with logistic regression. Software and manually measured diameters were compared with Spearman and Bland-Altman methods. Results: With sensitivity adjusted for 3-mm nodule detection, 50/100 (50%) subsolid nodules were detected, at the average cost of 17 CAD marks per CT. These figures were respectively 26/100 (26%) and 2 at the 5-mm setting. At the highest sensitivity setting (2-mm nodule detection), the average number of CAD marks per CT was 41 but the nodule detection rate only increased to 54%. Part–solid nodules were better detected than pure ground glass nodules: 36/50 (72%) versus 14/50 (28%) at the 3-mm setting (p < 0.0001), with no influence of the solid component size. Except for the type (i.e. part solid or pure ground glass), no other nodule characteristic influenced the detection rate. High-quality segmentation was obtained for 79 nodules, which for automated measurements correlated well with manual measurements (rho = 0.90[0.84–0.93]). All part-solid nodules had software-measured attenuation values above −671 Hounsfield units (HU). Conclusion: The detection rate of subsolid nodules by this CAD system was insufficient, but high-quality segmentation was obtained in 79% of

  8. Workflow of CAD / CAM Scoliosis Brace Adjustment in Preparation Using 3D Printing.

    Science.gov (United States)

    Weiss, Hans-Rudolf; Tournavitis, Nicos; Nan, Xiaofeng; Borysov, Maksym; Paul, Lothar

    2017-01-01

    High correction bracing is the most effective conservative treatment for patients with scoliosis during growth. Still today braces for the treatment of scoliosis are made by casting patients while computer aided design (CAD) and computer aided manufacturing (CAM) is available with all possibilities to standardize pattern specific brace treatment and improve wearing comfort. CAD / CAM brace production mainly relies on carving a polyurethane foam model which is the basis for vacuuming a polyethylene (PE) or polypropylene (PP) brace. Purpose of this short communication is to describe the workflow currently used and to outline future requirements with respect to 3D printing technology. Description of the steps of virtual brace adjustment as available today are content of this paper as well as an outline of the great potential there is for the future 3D printing technology. For 3D printing of scoliosis braces it is necessary to establish easy to use software plug-ins in order to allow adding 3D printing technology to the current workflow of virtual CAD / CAM brace adjustment. Textures and structures can be added to the brace models at certain well defined locations offering the potential of more wearing comfort without losing in-brace correction. Advances have to be made in the field of CAD / CAM software tools with respect to design and generation of individually structured brace models based on currently well established and standardized scoliosis brace libraries.

  9. Comprehensive Auto CAD

    International Nuclear Information System (INIS)

    Jang, Taekju

    1993-06-01

    This book starts introduction of conception, application system, software for CAD, function of Auto CAD, kinds and function of Auto CAD files. It deals with starting of Auto CAD, dialogue box and Auto CAD interface, utility command, 2D drawing command, check command, control system, dimension, hatching command, layer command, block, 3D drawing, plotting and printing, auto CAD and application of data, supply program of auto CAD, AME and region modeler, EDLIN, script optimization of Auto CAD and composition on demand.

  10. AutoCAD 2008 and AutoCAD LT 2008 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    "Whether you're new to AutoCAD or a veteran, you will undoubtedly find this book to be an excellent resource."-- Abhi Singh, AutoCAD Product Manager, Autodesk, Inc.Here's the book that makes AutoCAD approachableEven the people at Autodesk look to Ellen Finkelstein for AutoCAD training, so who better to teach you about AutoCAD 2008? This comprehensive guide brings veterans up to speed on AutoCAD updates and takes novices from the basics to programming in AutoLISP(r) and VBA. Every feature is covered in a logical order, and with the Quick Start chapter, you'll be creating drawings on your very f

  11. AutoCAD 2015 and AutoCAD LT 2015 bible

    CERN Document Server

    Finkelstein, Ellen

    2014-01-01

    The perfect reference for all AutoCAD users AutoCAD 2015 and AutoCAD LT 2015 Bible is the book you want to have close at hand to answer those day-to-day questions about this industry-leading software. Author and Autodesk University instructor Ellen Finkelstein guides readers through AutoCAD 2015 and AutoCAD LT 2015 with clear, easy-to-understand instruction and hands-on tutorials that allow even total beginners to create a design on their very first day. Although simple and fundamental enough to be used by those new to CAD, the book is so comprehensive that even Autodesk power u

  12. XML-based assembly visualization for a multi-CAD digital mock-up system

    International Nuclear Information System (INIS)

    Song, In Ho; Chung, Sung Chong

    2007-01-01

    Using a virtual assembly tool, engineers are able to design accurate and interference free parts without making physical mock-ups. Instead of a single CAD source, several CAD systems are used to design a complex product in a distributed design environment. In this paper, a multi-CAD assembly method is proposed through an XML and the lightweight CAD file. XML data contains a hierarchy of the multi-CAD assembly. The lightweight CAD file produced from various CAD files through the ACIS kemel and InterOp includes not only mesh and B-Rep data, but also topological data. It is used to visualize CAD data and to verify dimensions of the parts. The developed system is executed on desktop computers. It does not require commercial CAD systems to visualize 3D assembly data. Multi-CAD models have been assembled to verify the effectiveness of the developed DMU system on the Internet

  13. Research on remote sensing image pixel attribute data acquisition method in AutoCAD

    Science.gov (United States)

    Liu, Xiaoyang; Sun, Guangtong; Liu, Jun; Liu, Hui

    2013-07-01

    The remote sensing image has been widely used in AutoCAD, but AutoCAD lack of the function of remote sensing image processing. In the paper, ObjectARX was used for the secondary development tool, combined with the Image Engine SDK to realize remote sensing image pixel attribute data acquisition in AutoCAD, which provides critical technical support for AutoCAD environment remote sensing image processing algorithms.

  14. AutoCAD / AutoCAD LT 2014 fundamentals metric

    CERN Document Server

    ASCENT center for technical knowledge

    2014-01-01

    The objective of AutoCAD/AutoCAD LT 2014 Fundamentals is to enable students to create a basic 2D drawing in the AutoCAD software. Even at this fundamental level, the AutoCAD software is one of the most sophisticated computer applications that you are likely to encounter. Therefore learning to use it can be challenging. To make the process easier and provide flexibility for instructors and students, the training guide is divided into two parts that can be taken independently.

  15. AutoCAD electrical 2013 for electrical control designers

    CERN Document Server

    Tickoo, Sham; CADCIM Technologies

    2013-01-01

    The AutoCAD Electrical 2013 for Electrical Control Designers textbook has been written to assist the engineering students and the practicing designers learn the application of various AutoCAD Electrical tools and options for creating electrical control designs. After reading this textbook, the users will be able to create professional electrical-control drawings easily and effectively. Moreover, the users will be able to automate various control engineering tasks such as building circuits, numbering wires, creating bills of materials, and many more. The textbook takes the users across a wide spectrum of electrical control drawings through progressive examples and numerous illustrations and exercises, thereby making it an ideal guide for both the novice and the advanced users. Salient Features of the Textbook Consists of 14 chapters that are organized in a pedagogical sequence covering various tools and features of AutoCAD Electrical such as schematic drawings, parametric and non-parametric PLC modules, Circu...

  16. AutoCAD electrical 2016 for electrical control designers

    CERN Document Server

    Tickoo, Sham

    2016-01-01

    The AutoCAD Electrical 2016 for Electrical Control Designers textbook has been written to assist the engineering students and the practicing designers who are new to AutoCAD Electrical. Using this textbook, the readers can learn the application of basic tools required for creating professional electrical control drawings with the help of AutoCAD Electrical. Keeping in view the varied requirements of the users, this textbook covers a wide range of tools and features such as schematic drawings, Circuit Builder, panel drawings, parametric and nonparametric PLC modules, stand-alone PLC I/O points, ladder diagrams, point-to-point wiring diagrams, report generation, creation of symbols, and so on. This will help the readers to create electrical drawings easily and effectively. Special emphasis has been laid on the introduction of concepts, which have been explained using text and supported with graphical examples. The examples and tutorials used in this book ensure that the users can relate the information provided...

  17. Assessment of the Use of AutoCAD in Mechanical Engineering Technical Drawing Education

    OpenAIRE

    Akyürek, Turgut

    2018-01-01

    AutoCAD is one of the widely used software tools in engineering education. In this study, ageneral assessment of AutoCAD for the usage in the mechanical engineering technical drawing educationis made. AutoCAD is assessed in terms of the fulfilment of the requirements defined for the main twotechnical drawing courses. AutoCAD is assessed in terms of its capability in meeting the requirements ofthe technical drawing courses.

  18. Engineering drawing from first principles using AutoCAD

    CERN Document Server

    Maguire, Dennis E

    1998-01-01

    Engineering Drawing From First Principles is a guide to good draughting for students of engineering who need to learn how to produce technically accurate and detailed designs to British and International Standards. Written by Dennis Maguire, an experienced author and City and Guilds chief examiner, this text is designed for use on Further Education and University courses where a basic understanding of draughtsmanship and CAD is necessary. Although not written as an AutoCAD tutor, the book will be a useful introduction to good CAD practice.Part of the Revision and Self-Assessmen

  19. Digital Sketch Modelling: Integrating Digital Sketching as a Transition between Sketching and CAD in Industrial Design Education

    Science.gov (United States)

    Ranscombe, Charlie; Bissett-Johnson, Katherine

    2017-01-01

    Literature on the use of design tools in educational settings notes an uneasy relationship between student use of traditional hand sketching and digital modelling tools (CAD) during the industrial design process. This is often manifested in the transition from sketching to CAD and exacerbated by a preference of current students to use CAD. In this…

  20. Web-based computer-aided-diagnosis (CAD) system for bone age assessment (BAA) of children

    Science.gov (United States)

    Zhang, Aifeng; Uyeda, Joshua; Tsao, Sinchai; Ma, Kevin; Vachon, Linda A.; Liu, Brent J.; Huang, H. K.

    2008-03-01

    Bone age assessment (BAA) of children is a clinical procedure frequently performed in pediatric radiology to evaluate the stage of skeletal maturation based on a left hand and wrist radiograph. The most commonly used standard: Greulich and Pyle (G&P) Hand Atlas was developed 50 years ago and exclusively based on Caucasian population. Moreover, inter- & intra-observer discrepancies using this method create a need of an objective and automatic BAA method. A digital hand atlas (DHA) has been collected with 1,400 hand images of normal children from Asian, African American, Caucasian and Hispanic descends. Based on DHA, a fully automatic, objective computer-aided-diagnosis (CAD) method was developed and it was adapted to specific population. To bring DHA and CAD method to the clinical environment as a useful tool in assisting radiologist to achieve higher accuracy in BAA, a web-based system with direct connection to a clinical site is designed as a novel clinical implementation approach for online and real time BAA. The core of the system, a CAD server receives the image from clinical site, processes it by the CAD method and finally, generates report. A web service publishes the results and radiologists at the clinical site can review it online within minutes. This prototype can be easily extended to multiple clinical sites and will provide the foundation for broader use of the CAD system for BAA.

  1. AutoCAD 2012 and AutoCAD LT 2012 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    The latest version of this perennial favorite, in-depth, reference-tutorial This top-selling book has been updated by AutoCAD guru and author Ellen Finkelstein to provide you with the very latest coverage of both AutoCAD 2012 and AutoCAD LT 2012. It begins with a Quick Start tutorial, so you start creating right away. From there, the book covers so much in-depth material on AutoCAD that it is said that even Autodesk employees keep this comprehensive book at their desks. A DVD is included that features before-and-after drawings of all the tutorials and plenty of great examples from AutoCAD prof

  2. CAD/CAM: improved design quality, increased productivity

    Energy Technology Data Exchange (ETDEWEB)

    Evans, D. E.; England, J.

    1980-01-01

    Maintaining productivity levels while assuring the quality of engineering products grows increasingly more difficult and costly for industries such as the energy industry which are heavily committed to product design. The man/machine interface made possible through the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology can be applied to the design process as a tool for increased control to assure the quality of the final engineering product. The quality-control aspects of CAD/CAM technology are addressed in this presentation.

  3. Computer-aided pulmonary nodule detection. Performance of two CAD systems at different CT dose levels

    International Nuclear Information System (INIS)

    Hein, Patrick Alexander; Rogalla, P.; Klessen, C.; Lembcke, A.; Romano, V.C.

    2009-01-01

    Purpose: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). Materials and Methods: Multi-slice computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120kV tube voltage (1 mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Results: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72% and 62% (CAD-1 vs. CAD-2) for SD-CT and with 73% and 56% for ULD-CT. Median also positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83% and 61% for SD-CT and to 89% and 67% for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p>0.05). Conclusion: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems. (orig.)

  4. Geometric data transfer between CAD systems: solid models

    DEFF Research Database (Denmark)

    Kroszynski, Uri; Palstroem, Bjarne; Trostmann, Erik

    1989-01-01

    The first phase of the ESPRIT project CAD*I resulted in a specification for the exchange of solid models as well as in some pilot implementations of processors based on this specification. The authors summarize the CAD*I approach, addressing the structure of neutral files for solids, entities......, and attributes supporting three kinds of representations: facilities for the transfer of parametric designs; referencing library components; and other general mechanisms. They also describe the current state of the specification and processor implementations and include an example of a CAD*I neutral file....... Results from cycle and intersystem solid model transfer tests are presented, showing the practicality of the CAD*I proposal. B-rep model transfer results are discussed in some detail. The relationship of this work to standardization efforts is outlined...

  5. Solitary Pulmonary Nodule on Helical Dynamic CT Scans: Analysis of the Enhancement Patterns Using a Computer-Aided Diagnosis (CAD) System

    International Nuclear Information System (INIS)

    Choi, Eun Jung; Jin, Gong Yong; Han, Young Min; Lee, Young Sun; Kweon, Keun Sang

    2008-01-01

    We wanted to investigate the usefulness of a computer-aided diagnosis (CAD) system in assisting radiologists to diagnosis malignant solitary pulmonary nodules (SPNs), as compared with diagnosing SPNs with using direct personal drawing. Forty patients with SPNs were analyzed. After the pre-contrast scan was performed, an additional ten series of post-contrast images were obtained at 20-second intervals. Two investigators measured the attenuation values of the SPNs: a radiologist who drew the regions of interest (ROIs), and a technician who used a CAD system. The Bland and Altman plots were used to compare the net enhancement between a CAD system and direct personal drawing. The diagnostic characteristics of the malignant SPNs were calculated by considering the CAD and direct personal drawing and with using Fisher's exact test. On the Bland and Altman plot, the net enhancement difference between the CAD system and direct personal drawing was not significant (within ± 2 standard deriation). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of diagnosing malignant SPNs using CAD was 92%, 85%, 75%, 96% and 88%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of diagnosing malignant SPNs using direct drawing was 92%, 89%, 79%, 92% and 88%, respectively. The CAD system was a useful tool for diagnosing malignant SPNs

  6. Automation in the Teaching of Descriptive Geometry and CAD. High-Level CAD Templates Using Script Languages

    Science.gov (United States)

    Moreno, R.; Bazán, A. M.

    2017-10-01

    The main purpose of this work is to study improvements to the learning method of technical drawing and descriptive geometry through exercises with traditional techniques that are usually solved manually by applying automated processes assisted by high-level CAD templates (HLCts). Given that an exercise with traditional procedures can be solved, detailed step by step in technical drawing and descriptive geometry manuals, CAD applications allow us to do the same and generalize it later, incorporating references. Traditional teachings have become obsolete and current curricula have been relegated. However, they can be applied in certain automation processes. The use of geometric references (using variables in script languages) and their incorporation into HLCts allows the automation of drawing processes. Instead of repeatedly creating similar exercises or modifying data in the same exercises, users should be able to use HLCts to generate future modifications of these exercises. This paper introduces the automation process when generating exercises based on CAD script files, aided by parametric geometry calculation tools. The proposed method allows us to design new exercises without user intervention. The integration of CAD, mathematics, and descriptive geometry facilitates their joint learning. Automation in the generation of exercises not only saves time but also increases the quality of the statements and reduces the possibility of human error.

  7. KiCad challenges the big ones

    CERN Document Server

    Antonella Del Rosso

    2015-01-01

    Printed Circuit Boards (PCB) are the heart of any electronic device, including your toaster and your smartphone. Designing PCBs is the job of electronic engineers who, so far, have often had no option but to use proprietary tools to design complex circuits. Thanks to the efforts that CERN experts have put in to improve the free KiCad software, that situation is about to change.   KiCad's development started in 1992 as a way to design PCBs, the units that control how an electronic device works. Since 2013, experts in the Beams department have made important contributions to KiCad as part of the Open Hardware Initiative (OHI), which provides a framework to facilitate knowledge exchange across the electronic design community. “Our vision is to allow the hardware developers to share as easily as their software colleagues,” says Javier Serrano, head of the BE-CO-HT section and OHI initiator. “Software sources are easily shared online because they are text ...

  8. User interface issues in radiotherapy CAD software. 116

    International Nuclear Information System (INIS)

    Sherouse, G.W.; Mosher, C.E. Jr.

    1987-01-01

    A major growth area in computerized planning of radiotherapy over the last five years has been the development of programs for treatment design based on the interactive graphic display of three dimensional patient models. This word has been recognized as being a close relative of Computer-Aided Design (CAD) software which is used in industry for a broad spectrum of engineering and design applications. A CAD system for radiotherapy has been constructed which combines some of the more attractive aspects of other institutions' treatment design systems with CAD technology and a user interface which is designed for use by clinicians. The importance of an appropriate user interface cannot be overemphasized and is often sadly neglected in radiotherapy software. In order to realize the potential of this new treatment design technology it is essential that clinicians, particularly physicians, perceive RT CAD systems as tools rather than as obstacles. It is felt that thhe best way to achieve that perception is for the software to implement a superset of the functions used in conventional practice while retaining the ambiance of the traditional methods. It is the aim to construct a system which an experienced physician or dosimetrist can use with essentially no retraining. The model for this CAD tool is that of a virtual simulator. It is meant to faithfully reproduce both the function and the feel of a physical simulator. A number of techniques has been identified for realizing this goal. These include simple intuitive input devices, natural coordinate systems graphic interaction, good interactive responsiveness, and high-quality 3D display modalities. Here a description of these techniques and some details of their implementation is presented. 10 refs.; 2 figs

  9. Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammography

    International Nuclear Information System (INIS)

    Ciatto, Stefano; Del Turco, Marco Rosselli; Risso, Gabriella; Catarzi, Sandra; Bonardi, Rita; Viterbo, Valeria; Gnutti, Pierangela; Guglielmoni, Barbara; Pinelli, Lelio; Pandiscia, Anna; Navarra, Francesco; Lauria, Adele; Palmiero, Rosa; Indovina, Pietro Luigi

    2003-01-01

    Objective: To evaluate the role of computer aided detection (CAD) in improving the interpretation of screening mammograms Material and methods: Ten radiologists underwent a proficiency test of screening mammography first by conventional reading and then with the help of CAD. Radiologists were blinded to test results for the whole study duration. Results of conventional and CAD reading were compared in terms of sensitivity and recall rate. Double reading was simulated combining conventional readings of four expert radiologists and compared with CAD reading. Results: Considering all ten readings, cancer was identified in 146 or 153 of 170 cases (85.8 vs. 90.0%; χ 2 =0.99, df=1, P=0.31) and recalls were 106 or 152 of 1330 cases (7.9 vs. 11.4%; χ 2 =8.69, df=1, P=0.003) at conventional or CAD reading, respectively. CAD reading was essentially the same (sensitivity 97.0 vs. 96.0%; χ 2 =7.1, df=1, P=0.93; recall rate 10.7 vs. 10.6%; χ 2 =1.5, df=1, P=0.96) as compared with simulated conventional double reading. Conclusion: CAD reading seems to improve the sensitivity of conventional reading while reducing specificity, both effects being of limited size. CAD reading had almost the same performance of simulated conventional double reading, suggesting a possible use of CAD which needs to be confirmed by further studies inclusive of cost-effective analysis

  10. FY1995 transduction method and CAD database systems for integrated design; 1995 nendo transduction ho to CAD database togo sekkei shien system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Transduction method developed by the research coordinator and Prof. Muroga is one of the most popular methods to design large-scale integrated circuits, and thus used by major design tool companies in USA and Japan. The major objectives of the research is to improve capability and utilize its reusable property by combining with CAD databases. Major results of the project is as follows, (1) Improvement of Transduction method : Efficiency, capability and the maximum circuit size are improved. Error compensation method is also improved. (2) Applications to new logic elements : Transduction method is modified to cope with wired logic and FPGAs. (3) CAD databases : One of the major advantages of Transduction methods is 'reusability' of already designed circuits. It is suitable to combine with CAD databases. We design CAD databases suitable for cooperative design using Transduction method. (4) Program development : Programs for Windows95 and developed for distribution. (NEDO)

  11. FY1995 transduction method and CAD database systems for integrated design; 1995 nendo transduction ho to CAD database togo sekkei shien system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Transduction method developed by the research coordinator and Prof. Muroga is one of the most popular methods to design large-scale integrated circuits, and thus used by major design tool companies in USA and Japan. The major objectives of the research is to improve capability and utilize its reusable property by combining with CAD databases. Major results of the project is as follows, (1) Improvement of Transduction method : Efficiency, capability and the maximum circuit size are improved. Error compensation method is also improved. (2) Applications to new logic elements : Transduction method is modified to cope with wired logic and FPGAs. (3) CAD databases : One of the major advantages of Transduction methods is 'reusability' of already designed circuits. It is suitable to combine with CAD databases. We design CAD databases suitable for cooperative design using Transduction method. (4) Program development : Programs for Windows95 and developed for distribution. (NEDO)

  12. Bomb CAD

    International Nuclear Information System (INIS)

    Massa, R.J.; Howard, J.W.

    1989-01-01

    This paper describes BombCAD a computer-aided analysis technique for assessing the damage to diverse structures which results from specific high explosive detonations within or near the structure. BombCAD analyzes the vulnerability of specific facilities to bomb attach, and evaluates siting, screening and hardening/softening aspects of comprehensive bomb defense programs. The paper describes BombCAD's architectural models of specific structures, computations of blastwave effects and the paradigms which relate blast wave effects to both structural damage and human injury. The use of BombCAD in bomb attack vulnerability assessment, facility design, bomb threat response planning and post-incident analyses is described and field examples are presented

  13. Automatic generation of virtual worlds from architectural and mechanical CAD models

    International Nuclear Information System (INIS)

    Szepielak, D.

    2003-12-01

    Accelerator projects like the XFEL or the planned linear collider TESLA involve extensive architectural and mechanical design work, resulting in a variety of CAD models. The CAD models will be showing different parts of the project, like e.g. the different accelerator components or parts of the building complexes, and they will be created and stored by different groups in different formats. A complete CAD model of the accelerator and its buildings is thus difficult to obtain and would also be extremely huge and difficult to handle. This thesis describes the design and prototype development of a tool which automatically creates virtual worlds from different CAD models. The tool will enable the user to select a required area for visualization on a map, and then create a 3D-model of the selected area which can be displayed in a web-browser. The thesis first discusses the system requirements and provides some background on data visualization. Then, it introduces the system architecture, the algorithms and the used technologies, and finally demonstrates the capabilities of the system using two case studies. (orig.)

  14. Process and Tool Innovation for CAD Integration with OLTARIS, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA uses computer aided design (CAD) capabilities to produce space vehicle designs. One aspect of the vehicle design is utilizing enough shielding to minimize dose...

  15. Process and Tool Innovation for CAD Integration with OLTARIS, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA uses computer aided design (CAD) capabilities to produce space vehicle designs. One aspect of the vehicle design is utilizing enough shielding to minimize dose...

  16. Integration of computer-aided diagnosis/detection (CAD) results in a PACS environment using CAD-PACS toolkit and DICOM SR

    International Nuclear Information System (INIS)

    Le, Anh H.T.; Liu, Brent; Huang, H.K.

    2009-01-01

    Picture Archiving and Communication System (PACS) is a mature technology in health care delivery for daily clinical imaging service and data management. Computer-aided detection and diagnosis (CAD) utilizes computer methods to obtain quantitative measurements from medical images and clinical information to assist clinicians to assess a patient's clinical state more objectively. CAD needs image input and related information from PACS to improve its accuracy; and PACS benefits from CAD results online and available at the PACS workstation as a second reader to assist physicians in the decision making process. Currently, these two technologies remain as two separate independent systems with only minimal system integration. This paper describes a universal method to integrate CAD results with PACS in its daily clinical environment. The method is based on Health Level 7 (HL7) and Digital imaging and communications in medicine (DICOM) standards, and Integrating the Healthcare Enterprise (IHE) workflow profiles. In addition, the integration method is Health Insurance Portability and Accountability Act (HIPAA) compliant. The paper presents (1) the clinical value and advantages of integrating CAD results in a PACS environment, (2) DICOM Structured Reporting formats and some important IHE workflow profiles utilized in the system integration, (3) the methodology using the CAD-PACS integration toolkit, and (4) clinical examples with step-by-step workflows of this integration. (orig.)

  17. Innovation problems of new technologies - the introduction of CAD to mechnical engineering

    Energy Technology Data Exchange (ETDEWEB)

    Riehm, U; Rader, M

    1982-01-01

    The introduction of CAD (computer aided design) is accompanied by uncertainties in the estimation of the needs, the effectivity and the consequence of the application of CAD. Similar uncertainties have also been observed in the past during the introduction of NC-tooling machines. These problems can be solved by a parallel scientific evaluation of the experience made. This is the main purpose of a social science study accomaniing the introduction of CAD, which is presented here.

  18. PopupCAD: a tool for automated design, fabrication, and analysis of laminate devices

    Science.gov (United States)

    Aukes, Daniel M.; Wood, Robert J.

    2015-05-01

    Recent advances in laminate manufacturing techniques have driven the development of new classes of millimeter-scale sensorized medical devices, robots capable of terrestrial locomotion and sustained flight, and new techniques for sensing and actuation. Recently, the analysis of laminate micro-devices has focused more manufacturability concerns and not on mechanics. Considering the nature of such devices, we draw from existing research in composites, origami kinematics, and finite element methods in order to identify issues related to sequential assembly and self-folding prior to fabrication as well as the stiffness of composite folded systems during operation. These techniques can be useful for understanding how such devices will bend and flex under normal operating conditions, and when added to new design tools like popupCAD, will give designers another means to develop better devices throughout the design process.

  19. Application of CAD/CAE/CAM in forging process: a review

    International Nuclear Information System (INIS)

    Ahmad Baharuddin Abdullah; Hamouda, A.M.S.

    2005-01-01

    Forging can be described as the process in which metal is plastically deformed with application of huge pressure. The process not only changes the shape but also improves the properties of the forged parts due to grain size refinement. Conventionally, the empirical trial and error method has been applied, but recently there are various tools are employed to improved product quality and economic of the process. For example, Computer Aided Design (CAD) is widely used in modeling of the process, while Computer Aided Engineering (CAE) tools have been utilized in analyzing the process. To physically demonstrate the process, Computer Aided Manufacturing (CAM) such as CNC machine has been exploited. In order to improve forging process efficiency, an integrated system that combines all advantages of CAD, CAM and CAE need to be developed. This paper presents an overview of computer aided simulation such as CAD, CAE and CAM application in forging process. (Author)

  20. CAD-based Monte Carlo automatic modeling method based on primitive solid

    International Nuclear Information System (INIS)

    Wang, Dong; Song, Jing; Yu, Shengpeng; Long, Pengcheng; Wang, Yongliang

    2016-01-01

    Highlights: • We develop a method which bi-convert between CAD model and primitive solid. • This method was improved from convert method between CAD model and half space. • This method was test by ITER model and validated the correctness and efficiency. • This method was integrated in SuperMC which could model for SuperMC and Geant4. - Abstract: Monte Carlo method has been widely used in nuclear design and analysis, where geometries are described with primitive solids. However, it is time consuming and error prone to describe a primitive solid geometry, especially for a complicated model. To reuse the abundant existed CAD models and conveniently model with CAD modeling tools, an automatic modeling method for accurate prompt modeling between CAD model and primitive solid is needed. An automatic modeling method for Monte Carlo geometry described by primitive solid was developed which could bi-convert between CAD model and Monte Carlo geometry represented by primitive solids. While converting from CAD model to primitive solid model, the CAD model was decomposed into several convex solid sets, and then corresponding primitive solids were generated and exported. While converting from primitive solid model to the CAD model, the basic primitive solids were created and related operation was done. This method was integrated in the SuperMC and was benchmarked with ITER benchmark model. The correctness and efficiency of this method were demonstrated.

  1. A/E/C Graphics Standard: Release 2.0 (formerly titled CAD Drafting Standard)

    Science.gov (United States)

    2015-08-01

    acronyms: • A/E/C – Architecture , Engineering, and Construction • BIM – Building Information Modeling • CAD – Computer-Aided Design • CIM – Civil...title GENERAL NOTES. General notes applicable to sheets for a particular discipline (e.g., architectural , electrical, mechanical) shall be located on...Filled fonts are used primarily for titles and on cover sheets. • Symbol font: This font should be used in cases where Greek symbols are

  2. Convex-based void filling method for CAD-based Monte Carlo geometry modeling

    International Nuclear Information System (INIS)

    Yu, Shengpeng; Cheng, Mengyun; Song, Jing; Long, Pengcheng; Hu, Liqin

    2015-01-01

    Highlights: • We present a new void filling method named CVF for CAD based MC geometry modeling. • We describe convex based void description based and quality-based space subdivision. • The results showed improvements provided by CVF for both modeling and MC calculation efficiency. - Abstract: CAD based automatic geometry modeling tools have been widely applied to generate Monte Carlo (MC) calculation geometry for complex systems according to CAD models. Automatic void filling is one of the main functions in the CAD based MC geometry modeling tools, because the void space between parts in CAD models is traditionally not modeled while MC codes such as MCNP need all the problem space to be described. A dedicated void filling method, named Convex-based Void Filling (CVF), is proposed in this study for efficient void filling and concise void descriptions. The method subdivides all the problem space into disjointed regions using Quality based Subdivision (QS) and describes the void space in each region with complementary descriptions of the convex volumes intersecting with that region. It has been implemented in SuperMC/MCAM, the Multiple-Physics Coupling Analysis Modeling Program, and tested on International Thermonuclear Experimental Reactor (ITER) Alite model. The results showed that the new method reduced both automatic modeling time and MC calculation time

  3. Progress of computer-aided detection/diagnosis (CAD in dentistryCAD in dentistry

    Directory of Open Access Journals (Sweden)

    Akitoshi Katsumata

    2014-08-01

    CAD is also useful in the detection and evaluation of dental and maxillofacial lesions. Identifying alveolar bone resorption due to periodontitis and radiolucent jaw lesions (such as radicular and dentigerous cysts are important goals for CAD. CAD can be applied not only to panoramic radiography but also to dental cone-beam computed tomography (CBCT images. Linking of CAD and teleradiology will be an important issue.

  4. Instant Autodesk AutoCAD 2014 customization with .NET

    CERN Document Server

    Nelson, Tom

    2013-01-01

    Filled with practical, step-by-step instructions and clear explanations for the most important and useful tasks. An instruction-based guide with examples written in the C# programming language. VB.NET programmers can also take advantage of these examples by using one of the free conversion websites to convert the examples to VB.NET.Clear, step-by-step instructions and complete code examples illustrate the processes, making it easy to develop your own custom AutoCAD tools.This book is perfect if you are interested in customizing AutoCAD 2014 using the .NET API. You should have a basic familiari

  5. AutoCAD 2015 and AutoCAD LT 2015 essentials

    CERN Document Server

    Onstott, Scott

    2014-01-01

    Step-by-step instructions for the AutoCAD fundamentals AutoCAD 2015 Essentials contains 400 pages of full-color, comprehensive instruction on the world's top drafting and architecture software. This 2015 edition features architectural, manufacturing, and landscape architecture examples. And like previous editions, the detailed guide introduces core concepts using interactive tutorials and open-ended projects, which can be completed in any order, thanks to downloadable data sets (an especially useful feature for students and professionals studying for Autodesk AutoCAD certification). Unlike man

  6. MS AutoCad

    DEFF Research Database (Denmark)

    Andersen, Michael Rye; Heinicke, Hugo

    1996-01-01

    Formålet med dette notat er at give en introduktion til tegning af et generalarrangement ved anvendelse af CAD-programmet AutoCAD. Generalarrangementets formål er at skabe en overskuelig præsentation af et skibsprojekt. Det skal gøres indenfor de rammer, som ligger til grund for praktiskprojekter......Formålet med dette notat er at give en introduktion til tegning af et generalarrangement ved anvendelse af CAD-programmet AutoCAD. Generalarrangementets formål er at skabe en overskuelig præsentation af et skibsprojekt. Det skal gøres indenfor de rammer, som ligger til grund...

  7. TGeoCad: an Interface between ROOT and CAD Systems

    International Nuclear Information System (INIS)

    Luzzi, C; Carminati, F

    2014-01-01

    In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems

  8. TGeoCad: an Interface between ROOT and CAD Systems

    Science.gov (United States)

    Luzzi, C.; Carminati, F.

    2014-06-01

    In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems.

  9. Use of McCad for the conversion of ITER CAD data to MCNP geometry

    International Nuclear Information System (INIS)

    Tsige-Tamirat, H.; Fischer, U.; Serikov, A.; Stickel, S.

    2008-01-01

    The program McCad provides a CAD interface for the Monte Carlo transport code MCNP. It is able to convert CAD data into MCNP input geometry description and provides GUI components for modeling, visualization, and data exchange. It performs sequences of tests on CAD data to check its validity and neutronics appropriateness including completion of the final MCNP model by void geometries. McCad has been used to convert a 40 deg. ITER torus sector CAD model to a suitable MCNP geometry model. Results of MCNP calculations performed to validate the converted geometry are presented

  10. Potential benefits of a CAD package for designing multivariable control systems

    International Nuclear Information System (INIS)

    Mensah, S.

    1983-01-01

    An open-ended CAD package, MVPACK, has been developed and implemented on a PDP-11/45 minicomputer at the Chalk River Nuclear Laboratories. The package is fully interactive, and includes a comprehensive state-of-the-art methematical library to support development of complex multi-variable control algorithms. Coded in RATFOR, MVPACK operates with a flexible data structure which makes efficient use of minicomputer resources and provides a standard framework for program generation. The existence of a help mechanism enhances the simplicity of package utilization. The capability of the package as a tool for designing control systems is illustrated with the design of a regulating system for an evaporator

  11. Microscopic simulation model of superconducting transmission lines for standard microwave CAD programs

    International Nuclear Information System (INIS)

    Hoefer, G.J.; Kratz, H.A.

    1993-01-01

    Superconducting lines are very promising candidates for fast signal transmission in integrated circuits, because of their low losses and dispersion, which result in large usable bandwidths. Coplanar waveguides are of special interest, since only one superconducting layer is needed for their implementation. This requirement fits well the present day capabilities of the high temperature superconductor technology. At present, the major drawback of this type of transmission line is the lack of accurate and fast CAD models including the special properties of superconducting electrodes. In the following we will briefly describe the essentials of a model for the case of superconducting lines. For a complete description the reader is referenced to. The model has been proven to be useful in conjunction with commercially available microwave CAD programs. (orig.)

  12. DESIGN REVIEW OF CAD MODELS USING A NUI LEAP MOTION SENSOR

    Directory of Open Access Journals (Sweden)

    GÎRBACIA Florin

    2015-06-01

    Full Text Available Natural User Interfaces (NUI is a relatively new area of research that aims to develop humancomputer interfaces, natural and intuitive, using voice commands, hand movements and gesture recognition, similar to communication between people which also implies body language and gestures. In this paper is presented a natural designed workspace which acquires the user's motion using a Leap Motion sensor and visualizes the CAD models using a CAVE-like 3D visualisation system. The user can modify complex CAD models using bimanual gesture commands in a 3D virtual environment. The developed bimanual gestures for rotate, pan, zoom and explode are presented. From the conducted experiments is established that Leap Motion NUI sensor provides an intuitive tool for design review of CAD models, performed even by users with no experience in CAD systems and virtual environments.

  13. Development of CAD implementing the algorithm of boundary elements’ numerical analytical method

    Directory of Open Access Journals (Sweden)

    Yulia V. Korniyenko

    2015-03-01

    Full Text Available Up to recent days the algorithms for numerical-analytical boundary elements method had been implemented with programs written in MATLAB environment language. Each program had a local character, i.e. used to solve a particular problem: calculation of beam, frame, arch, etc. Constructing matrices in these programs was carried out “manually” therefore being time-consuming. The research was purposed onto a reasoned choice of programming language for new CAD development, allows to implement algorithm of numerical analytical boundary elements method and to create visualization tools for initial objects and calculation results. Research conducted shows that among wide variety of programming languages the most efficient one for CAD development, employing the numerical analytical boundary elements method algorithm, is the Java language. This language provides tools not only for development of calculating CAD part, but also to build the graphic interface for geometrical models construction and calculated results interpretation.

  14. Evaluation of effectiveness of a computer system (CAD) in the identification of lung nodules with low-dose MSCT: scanning technique and preliminary results

    International Nuclear Information System (INIS)

    Fraioli, Francesco; Catalano, Carlo; Almberger, Maria; Bertoletti, Linda; Cantisani, Vito; Danti, Massimiliano; Pediconi, Federica; Passariello, Roberto

    2005-01-01

    Purpose: Evaluation of the effectiveness of a computer-aided diagnosis (CAD) in the identification of pulmonary nodules. Materials and methods: Two observers (A1, A2) with different levels of experience independently evaluated 20 chest MSCT studies with and without the aid of a CAD system (LungCheck, R2 Technology, Inc.). The study parameters were as follows: 140 kVs, 40 mAs, collimation 4x1 mm, slice thickness 1.25 mm, reconstruction interval 1.0 mm. The observers analysed the images with and without CAD and evaluated: 1) nodule size (longer axis); 2) number and location of nodules; 3) reading time for each observer. The gold standard was represented by the evaluation of both readers in consensus with the aid of the CAD system. Results: Without CAD support the two readers identified 77 (A1) and 79 (A2) nodules and with CAD 81 (A1) and 82 (A2) nodules. Working in consensus the two observers identified 81 nodules without the aid of CAD and 84 nodules with the aid of CAD. Total number of nodules identified by CAD was 104, 25 of which were false positive and 5 false negative. The average reading time with the aid of CAD decreased by as much as 40% for both the observers. Conclusions: The preliminary results of our study suggest that the CAD technique is an accurate automatic support tool in the identification of pulmonary nodules. It reduces reading time and automatically supplies the size, volume, density and number of nodules, thus being useful both in screening programmes and in the follow-up of cancer patients, in whom comparison of the images is particularly difficult [it

  15. A Case Study in CAD Design Automation

    Science.gov (United States)

    Lowe, Andrew G.; Hartman, Nathan W.

    2011-01-01

    Computer-aided design (CAD) software and other product life-cycle management (PLM) tools have become ubiquitous in industry during the past 20 years. Over this time they have continuously evolved, becoming programs with enormous capabilities, but the companies that use them have not evolved their design practices at the same rate. Due to the…

  16. AutoCAD 2008 for dummies

    CERN Document Server

    Byrnes, David

    2007-01-01

    A gentle, humorous introduction to this fearsomely complex software that helps new users start creating 2D and 3D technical drawings right awayCovers the new features and enhancements in the latest AutoCAD version and provides coverage of AutoCAD LT, AutoCAD''s lower-cost siblingTopics covered include creating a basic layout, using AutoCAD DesignCenter, drawing and editing, working with dimensions, plotting, using blocks, adding text to drawings, and drawing on the InternetAutoCAD is the leading CAD software for architects, engineers, and draftspeople who need to create detailed 2D and 3D tech

  17. The VE/CAD synergism

    International Nuclear Information System (INIS)

    Sperling, R.B.

    1993-01-01

    Value Engineering (VE) and Computer-Aided Design (CAD) can be used synergistically to reduce costs and improve facilities designs. The cost and schedule impacts of implementing alternative design ideas developed by VE teams can be greatly reduced when the drawings have been produced with interactive CAD systems. To better understand the interrelationship between VE and CAD, the fundamentals of the VE process are explained; and example of a VE proposal is described and the way CAD drawings facilitated its implementation is illustrated

  18. Refining a brief decision aid in stable CAD: cognitive interviews

    OpenAIRE

    Kelly-Blake, Karen; Clark, Stacie; Dontje, Katherine; Olomu, Adesuwa; Henry, Rebecca C; Rovner, David R; Rothert, Marilyn L; Holmes-Rovner, Margaret

    2014-01-01

    Background We describe the results of cognitive interviews to refine the “Making Choices©” Decision Aid (DA) for shared decision-making (SDM) about stress testing in patients with stable coronary artery disease (CAD). Methods We conducted a systematic development process to design a DA consistent with International Patient Decision Aid Standards (IPDAS) focused on Alpha testing criteria. Cognitive interviews were conducted with ten stable CAD patients using the “think aloud” interview techniq...

  19. Application of Auto CAD 2000

    International Nuclear Information System (INIS)

    Kim, Hyeong Jun

    1999-11-01

    This book deals with basic of AutoCAD, beginning AutoCAD 2000, using design center of AutoCAD 2000, adding drawing element with design center, drawing lines, using 2D edit command, making layer, hatching, dimensioning, entering letters on the floor plan, making 3D object, practice of 3D command, edition of 3D object, making solid, rendering object, and using internet in AutoCAD 2000. This book is introduction of AutoCAD 2000 for beginner.

  20. Easy Auto CAD

    International Nuclear Information System (INIS)

    Lee, Hyeon Jun

    1996-02-01

    This book explains Auto CAD easily, which introduces improved function in Auto CAD R 13, such as direct import and export of 3 DS pile, revised render order structure, and explanations of assist, view Draw, construct and modify. Next it gives descriptions of Auto CAD conception, application and system. The last part deals with line, arc, circle, ellipse, erase, undo, redo, redraw, line type, multi line, limits, zoom, move, copy, rotate, array, mirror, grid, snap, units, offset and poly line.

  1. Chairside CAD/CAM materials. Part 2: Flexural strength testing.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Petschelt, Anselm; Mevec, Daniel; Harrer, Walter; Lube, Tanja; Danzer, Robert; Lohbauer, Ulrich

    2017-01-01

    Strength is one of the preferred parameters used in dentistry for determining clinical indication of dental restoratives. However, small dimensions of CAD/CAM blocks limit reliable measurements with standardized uniaxial bending tests. The objective of this study was to introduce the ball-on-three-ball (B3B) biaxial strength test for dental for small CAD/CAM block in the context of the size effect on strength predicted by the Weibull theory. Eight representative chairside CAD/CAM materials ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Specimens were prepared with highly polished surfaces in rectangular plate (12×12×1.2mm 3 ) or round disc (Ø=12mm, thickness=1.2mm) geometries. Specimens were tested using the B3B assembly and the biaxial strength was determined using calculations derived from finite element analyses of the respective stress fields. Size effects on strength were determined based on results from 4-point-bending specimens. A good agreement was found between the biaxial strength results for the different geometries (plates vs. discs) using the B3B test. Strength values ranged from 110.9MPa (Vitablocs Mark II) to 1303.21MPa (e.max ZirCAD). The strength dependency on specimen size was demonstrated through the calculated effective volume/surface. The B3B test has shown to be a reliable and simple method for determining the biaxial strength restorative materials supplied as small CAD/CAM blocks. A flexible solution was made available for the B3B test in the rectangular plate geometry. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  2. Format conversion between CAD data and GIS data based on ArcGIS

    Science.gov (United States)

    Xie, Qingqing; Wei, Bo; Zhang, Kailin; Wang, Zhichao

    2015-12-01

    To make full use of the data resources and realize a sharing for the different types of data in different industries, a method of format conversion between CAD data and GIS data based on ArcGIS was proposed. To keep the integrity of the converted data, some key steps to process CAD data before conversion were made in AutoCAD. For examples, deleting unnecessary elements such as title, border and legend avoided the appearance of unnecessary elements after conversion, as layering data again by a national standard avoided the different types of elements to appear in a same layer after conversion. In ArcGIS, converting CAD data to GIS data was executed by the correspondence of graphic element classification between AutoCAD and ArcGIS. In addition, an empty geographic database and feature set was required to create in ArcGIS for storing the text data of CAD data. The experimental results show that the proposed method avoids a large amount of editing work in data conversion and maintains the integrity of spatial data and attribute data between before and after conversion.

  3. AutoCAD platform customization VBA

    CERN Document Server

    Ambrosius, Lee

    2015-01-01

    Boost productivity and streamline your workflow with expert AutoCAD: VBA programming instruction AutoCAD Platform Customization: VBA is the definitive guide to personalizing AutoCAD and the various programs that run on the AutoCAD platform, including AutoCAD Architecture, Civil 3D, Plant 3D, and more. Written by an Autodesk insider with years of customization and programming experience, this book features detailed discussions backed by real-world examples and easy-to-follow tutorials that illustrate each step in the personalization process. Readers gain expert guidance toward managing layout

  4. Particle tracking in sophisticated CAD models for simulation purposes

    International Nuclear Information System (INIS)

    Sulkimo, J.; Vuoskoski, J.

    1995-01-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT. (orig.)

  5. Particle tracking in sophisticated CAD models for simulation purposes

    Science.gov (United States)

    Sulkimo, J.; Vuoskoski, J.

    1996-02-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT.

  6. AutoCAD workbook

    CERN Document Server

    Metherell, Phil

    1989-01-01

    AutoCAD Workbook helps new users learn the basics of AutoCad, providing guidance on most of the commonly used functions in which the program operates.This book discusses loading AutoCad and starting a drawing; drawing and erasing lines, circles, and arcs; and setting up the drawing environment. The topics on drawing and editing polylines; entering text and text styles; and layers, linetype, and color are also considered. This publication likewise covers creating and using blocks, hatching and extracting information, dimensioning drawings, 3D visualization, and plotting a drawing. Other

  7. [The CAD-S, an instrument for the assessment of adaptation to divorce - separation].

    Science.gov (United States)

    Yárnoz Yaben, Sagrario; Comino González, Priscila

    2010-02-01

    The CAD-S, an Instrument for the Assessment of Adaptation to Divorce - Separation. This paper presents an instrument for the evaluation of the adaptation to divorce-separation. The CAD-S is a questionnaire created in Spanish, made up of 20 items whose aim is the evaluation of the family's adaptation to divorce-separation, using one of the parents as informant. Data were collected in four different samples of divorced persons and their children from different autonomous comunities from the Spanish state. 223 parents and 160 children from divorced families took part in this study. Four factors emerged, accounting for 52.39 percent of the total variance: psychological and emotional difficulties, conflict with the ex-partner, disposition to co-parentality, and negative outcomes of separation for children. The results suggest that CAD-S appears to be a reliable and valid instrument, with high internal consistency (Cronbach's alpha) and adequate construct validity supported by its relations with measures of satisfaction with life (SWLS), in the case of parents, and conduct problems (CBCL) for children.

  8. Computer-aided design in power engineering. Application of software tools

    International Nuclear Information System (INIS)

    Stojkovic, Zlatan

    2012-01-01

    Demonstrates the use software tools in the practice of design in the field of power systems. Presents many applications in the design in the field of power systems. Useful for educative purposes and practical work. This textbooks demonstrates the application of software tools in solving a series of problems from the field of designing power system structures and systems. It contains four chapters: The first chapter leads the reader through all the phases necessary in the procedures of computer aided modeling and simulation. It guides through the complex problems presenting on the basis of eleven original examples. The second chapter presents application of software tools in power system calculations of power systems equipment design. Several design example calculations are carried out using engineering standards like MATLAB, EMTP/ATP, Excel and Access, AutoCAD and Simulink. The third chapters focuses on the graphical documentation using a collection of software tools (AutoCAD, EPLAN, SIMARIS SIVACON, SIMARIS DESIGN) which enable the complete automation of the development of graphical documentation of a power systems. In the fourth chapter, the application of software tools in the project management in power systems is discussed. Here, the emphasis is put on the standard software MS Excel and MS Project.

  9. Computer-aided design in power engineering. Application of software tools

    Energy Technology Data Exchange (ETDEWEB)

    Stojkovic, Zlatan

    2012-07-01

    Demonstrates the use software tools in the practice of design in the field of power systems. Presents many applications in the design in the field of power systems. Useful for educative purposes and practical work. This textbooks demonstrates the application of software tools in solving a series of problems from the field of designing power system structures and systems. It contains four chapters: The first chapter leads the reader through all the phases necessary in the procedures of computer aided modeling and simulation. It guides through the complex problems presenting on the basis of eleven original examples. The second chapter presents application of software tools in power system calculations of power systems equipment design. Several design example calculations are carried out using engineering standards like MATLAB, EMTP/ATP, Excel and Access, AutoCAD and Simulink. The third chapters focuses on the graphical documentation using a collection of software tools (AutoCAD, EPLAN, SIMARIS SIVACON, SIMARIS DESIGN) which enable the complete automation of the development of graphical documentation of a power systems. In the fourth chapter, the application of software tools in the project management in power systems is discussed. Here, the emphasis is put on the standard software MS Excel and MS Project.

  10. Characterization analysis database system (CADS). A system overview

    International Nuclear Information System (INIS)

    1997-12-01

    The CADS database is a standardized, quality-assured, and configuration-controlled data management system developed to assist in the task of characterizing the DOE surplus HEU material. Characterization of the surplus HEU inventory includes identifying the specific material; gathering existing data about the inventory; defining the processing steps that may be necessary to prepare the material for transfer to a blending site; and, ultimately, developing a range of the preliminary cost estimates for those processing steps. Characterization focuses on producing commercial reactor fuel as the final step in material disposition. Based on the project analysis results, the final determination will be made as to the viability of the disposition path for each particular item of HEU. The purpose of this document is to provide an informational overview of the CADS database, its evolution, and its current capabilities. This document describes the purpose of CADS, the system requirements it fulfills, the database structure, and the operational guidelines of the system

  11. Neutronics analysis of the International Thermonuclear Experimental Reactor (ITER) MCNP ''Benchmark CAD Model'' with the ATTILA discrete ordinance code

    International Nuclear Information System (INIS)

    Youssef, M.Z.; Feder, R.; Davis, I.

    2007-01-01

    The ITER IT has adopted the newly developed FEM, 3-D, and CAD-based Discrete Ordinates code, ATTILA for the neutronics studies contingent on its success in predicting key neutronics parameters and nuclear field according to the stringent QA requirements set forth by the Management and Quality Program (MQP). ATTILA has the advantage of providing a full flux and response functions mapping everywhere in one run where components subjected to excessive radiation level and strong streaming paths can be identified. The ITER neutronics community had agreed to use a standard CAD model of ITER (40 degree sector, denoted ''Benchmark CAD Model'') to compare results for several responses selected for calculation benchmarking purposes to test the efficiency and accuracy of the CAD-MCNP approach developed by each party. Since ATTILA seems to lend itself as a powerful design tool with minimal turnaround time, it was decided to benchmark this model with ATTILA as well and compare the results to those obtained with the CAD MCNP calculations. In this paper we report such comparison for five responses, namely: (1) Neutron wall load on the surface of the 18 shield blanket module (SBM), (2) Neutron flux and nuclear heating rate in the divertor cassette, (3) nuclear heating rate in the winding pack of the inner leg of the TF coil, (4) Radial flux profile across dummy port plug and shield plug placed in the equatorial port, and (5) Flux at seven point locations situated behind the equatorial port plug. (orig.)

  12. Computer- Aided Design in Power Engineering Application of Software Tools

    CERN Document Server

    Stojkovic, Zlatan

    2012-01-01

    This textbooks demonstrates the application of software tools in solving a series of problems from the field of designing power system structures and systems. It contains four chapters: The first chapter leads the reader through all the phases necessary in the procedures of computer aided modeling and simulation. It guides through the complex problems presenting on the basis of eleven original examples. The second chapter presents  application of software tools in power system calculations of power systems equipment design. Several design example calculations are carried out using engineering standards like MATLAB, EMTP/ATP, Excel & Access, AutoCAD and Simulink. The third chapters focuses on the graphical documentation using a collection of software tools (AutoCAD, EPLAN, SIMARIS SIVACON, SIMARIS DESIGN) which enable the complete automation of the development of graphical documentation of a power systems. In the fourth chapter, the application of software tools in the project management in power systems ...

  13. CAD on personal computers

    International Nuclear Information System (INIS)

    Lee, Seong U; Cho, Cheol Ho; Ko, Il Du

    1990-02-01

    This book contains four studies of CAD on personal computers. The first thing is computer graphics in computer-aided design by Seong U Lee. The second thing is graphics primer and programming with Fortran by Seong U Lee. The third thing is application of Auto cad by Il Do Ko. The last thing is application of CAD in building construction design by Cheol Ho Cho.

  14. Tools for building Breast Cancer CAD methods; Herramientas para elaborar metodos de CAD del cancer de mama

    Energy Technology Data Exchange (ETDEWEB)

    Diaz-Herrero, G.; Franco-Valiente, J. M.; Suarez-Ortega, C.; Rubio del Solar, M.; Ramos-Pollam, R.; Guevara-Lopez, M. A.; Gonzalez de Posada, N.; Ramos, I.; Loureiro, J.

    2011-07-01

    This paper describes the main results of the collaboration currently ongoing between CETA-CIEMAT and the Faculty of Engineering at the University of Porto. It introduces the Mammography image Workstation for Analysis and Diagnosis (MIWAD) and the data analysis processes through which Grid infrastructures are used to develop Breast Cancer Computer-Aided Diagnosis (CAD) methods.MIWAD is a novel integrated software framework that integrates a specialized graphical user interface combining digital image processing, pattern recognition and artificial intelligence techniques. This paper describes its successful application in a pilot experience, on the first Portuguese Breast Cancer Digital Repository. (Author)

  15. The N4 CAD chain: Another electricite de France breakthrough in nuclear engineering

    International Nuclear Information System (INIS)

    Cornon, P.; Durey, P.

    1996-01-01

    With the previous pressurized water reactor (PWR) series (1300 MW), Electricite de France (EdF) has experienced the first chain of computer-aided design (CAD) tools from programming drawings to instrumentation and control microprocessor memories. The Engineering and Construction Division of EdF decided to integrate the CAD tools in the design and construction process of its new N4 series (1400-MW PWR). At that time, EdF determined four safety and data quality principles for the human/machine interface of the CAD: 1. Unique data capture: A common alphanumeric database shares all the information used by more than one application, so this information is typed only once and can be verified independently. 2. Intrinsic consistency: Added to the previous principle, data consistency is also ensured by every application that provides ways to enter only allowed data when it is possible. This is completed by some checking facilities. 3. Ergonomy: Making extensive use of windows, buttons, pictures, and wysiwyg facilities, the CAD section develops applications speaking the real language of every designer who is able to understand and verify her/his work. 4. On-line help: For any question, prompted by any application, some on-line help has been written giving the list of allowed answers with explanations and/or examples

  16. Rule-Based Design of Plant Expression Vectors Using GenoCAD.

    Science.gov (United States)

    Coll, Anna; Wilson, Mandy L; Gruden, Kristina; Peccoud, Jean

    2015-01-01

    Plant synthetic biology requires software tools to assist on the design of complex multi-genic expression plasmids. Here a vector design strategy to express genes in plants is formalized and implemented as a grammar in GenoCAD, a Computer-Aided Design software for synthetic biology. It includes a library of plant biological parts organized in structural categories and a set of rules describing how to assemble these parts into large constructs. Rules developed here are organized and divided into three main subsections according to the aim of the final construct: protein localization studies, promoter analysis and protein-protein interaction experiments. The GenoCAD plant grammar guides the user through the design while allowing users to customize vectors according to their needs. Therefore the plant grammar implemented in GenoCAD will help plant biologists take advantage of methods from synthetic biology to design expression vectors supporting their research projects.

  17. Adaptation Measurement of CAD/CAM Dental Crowns with X-Ray Micro-CT: Metrological Chain Standardization and 3D Gap Size Distribution

    Directory of Open Access Journals (Sweden)

    L. Tapie

    2016-01-01

    Full Text Available Computer-Aided Design and Manufacturing systems are increasingly used to produce dental prostheses, but the parts produced suffer from a lack of evaluation, especially concerning the internal gap of the final assembly, that is, the space between the prepared tooth and the prosthesis. X-ray micro-Computed Tomography (micro-CT is a noninvasive imaging technique enabling the internal inspection of the assembly. It has proved to be an efficient tool for measuring the gap. In this study, a critical review of the protocols using micro-CT to quantify the gap is proposed as an introduction to a new protocol aimed at minimizing errors and enabling comparison between CAD/CAM systems. To compare different systems, a standardized protocol is proposed including two reference geometries. Micro-CT is used to acquire the reference geometries. A new 3D method is then proposed and a new indicator is defined (Gap Size Distribution (GSD. In addition, the usual 2D measurements are described and discussed. The 3D gap measurement method proposed can be used in clinical case geometries and has the considerable advantage of minimizing the data processing steps before performing the measurements.

  18. Vragenlijst ter beoordeling van beeldschermtekenfuncties (CAD)

    NARCIS (Netherlands)

    Berndsen, M.B.; Vaas, F.

    1990-01-01

    Deze vragenlijst is een hulpmiddel om beeldscherm-tekenfuncties (CAD) waarbij gebruik wordt gemaakt van CAD-apparatuur, te beoordelen. Het gaat hierbij om functies waarin bij de hoofdtaken intensief met een beeldscherm wordt gewerkt, zoals het geval is bij de CAD-tekenaar, de CAD-instructeur en de

  19. Evaluation of Five Microcomputer CAD Packages.

    Science.gov (United States)

    Leach, James A.

    1987-01-01

    Discusses the similarities, differences, advanced features, applications and number of users of five microcomputer computer-aided design (CAD) packages. Included are: "AutoCAD (V.2.17)"; "CADKEY (V.2.0)"; "CADVANCE (V.1.0)"; "Super MicroCAD"; and "VersaCAD Advanced (V.4.00)." Describes the…

  20. Baseline Characteristics and Prescription Patterns of Standard Drugs in Patients with Angiographically Determined Coronary Artery Disease and Renal Failure (CAD-REF Registry.

    Directory of Open Access Journals (Sweden)

    Holger Reinecke

    Full Text Available Chronic kidney disease (CKD is strongly associated with coronary artery disease (CAD. We established a prospective observational nationwide multicenter registry to evaluate current treatment and outcomes in patients with both CKD and angiographically documented CAD.In 32 cardiological centers 3,352 CAD patients with ≥50% stenosis in at least one coronary artery were enrolled and classified according to their estimated glomerular filtration rate and proteinuria into one of five stages of CKD or as a control group.2,723 (81.2% consecutively enrolled patients suffered from CKD. Compared to controls, CKD patients had a higher prevalence of diabetes, hypertension, peripheral artery diseases, heart failure, and valvular heart disease (each p<0.001. Myocardial infarctions (p = 0.02, coronary bypass grafting, valve replacements and pacemaker implantations had been recorded more frequently (each p<0.001. With advanced CKD, the number of diseased coronary vessels and the proportion of patients with reduced left ventricular ejection fraction (LVEF increased significantly (both p<0.001. Percutaneous coronary interventions were performed less frequently (p<0.001 while coronary bypass grafting was recommended more often (p = 0.04 with advanced CKD. With regard to standard drugs in CAD treatment, prescriptions were higher in our registry than in previous reports, but beta-blockers (p = 0.008, and angiotensin-converting-enzyme inhibitors and/or angiotensin-receptor blockers (p<0.001 were given less often in higher CKD stages. In contrast, in the subgroup of patients with moderately to severely reduced LVEF the prescription rates did not differ between CKD stages. In-hospital mortality increased stepwise with each CKD stage (p = 0.02.In line with other studies comprising CKD cohorts, patients' morbidity and in-hospital mortality increased with the degree of renal impairment. Although cardiologists' drug prescription rates in CAD-REF were higher than in

  1. Integrating CAD modules in a PACS environment using a wide computing infrastructure.

    Science.gov (United States)

    Suárez-Cuenca, Jorge J; Tilve, Amara; López, Ricardo; Ferro, Gonzalo; Quiles, Javier; Souto, Miguel

    2017-04-01

    The aim of this paper is to describe a project designed to achieve a total integration of different CAD algorithms into the PACS environment by using a wide computing infrastructure. The aim is to build a system for the entire region of Galicia, Spain, to make CAD accessible to multiple hospitals by employing different PACSs and clinical workstations. The new CAD model seeks to connect different devices (CAD systems, acquisition modalities, workstations and PACS) by means of networking based on a platform that will offer different CAD services. This paper describes some aspects related to the health services of the region where the project was developed, CAD algorithms that were either employed or selected for inclusion in the project, and several technical aspects and results. We have built a standard-based platform with which users can request a CAD service and receive the results in their local PACS. The process runs through a web interface that allows sending data to the different CAD services. A DICOM SR object is received with the results of the algorithms stored inside the original study in the proper folder with the original images. As a result, a homogeneous service to the different hospitals of the region will be offered. End users will benefit from a homogeneous workflow and a standardised integration model to request and obtain results from CAD systems in any modality, not dependant on commercial integration models. This new solution will foster the deployment of these technologies in the entire region of Galicia.

  2. Computing tools for implementing standards for single-case designs.

    Science.gov (United States)

    Chen, Li-Ting; Peng, Chao-Ying Joanne; Chen, Ming-E

    2015-11-01

    In the single-case design (SCD) literature, five sets of standards have been formulated and distinguished: design standards, assessment standards, analysis standards, reporting standards, and research synthesis standards. This article reviews computing tools that can assist researchers and practitioners in meeting the analysis standards recommended by the What Works Clearinghouse: Procedures and Standards Handbook-the WWC standards. These tools consist of specialized web-based calculators or downloadable software for SCD data, and algorithms or programs written in Excel, SAS procedures, SPSS commands/Macros, or the R programming language. We aligned these tools with the WWC standards and evaluated them for accuracy and treatment of missing data, using two published data sets. All tools were tested to be accurate. When missing data were present, most tools either gave an error message or conducted analysis based on the available data. Only one program used a single imputation method. This article concludes with suggestions for an inclusive computing tool or environment, additional research on the treatment of missing data, and reasonable and flexible interpretations of the WWC standards. © The Author(s) 2015.

  3. CAD, 3D modeling, engineering analysis, and prototype experimentation industrial and research applications

    CERN Document Server

    Zheng Li, Jeremy

    2015-01-01

    This succinct book focuses on computer aided design (CAD), 3-D modeling, and engineering analysis and the ways they can be applied effectively in research and industrial sectors including aerospace, defense, automotive, and consumer products. These efficient tools, deployed for R&D in the laboratory and the field, perform efficiently three-dimensional modeling of finished products, render complex geometrical product designs, facilitate structural analysis and optimal product design, produce graphic and engineering drawings, and generate production documentation. Written with an eye toward green energy installations and novel manufacturing facilities, this concise volume enables scientific researchers and engineering professionals to learn design techniques, control existing and complex issues, proficiently use CAD tools, visualize technical fundamentals, and gain analytic and technical skills. This book also: ·       Equips practitioners and researchers to handle powerful tools for engineering desi...

  4. Multifunctional facades - design optimisation with CAD; Multifunktionale Fassaden - Effektive Auslegung durch CAD-Einsatz

    Energy Technology Data Exchange (ETDEWEB)

    Viotto, M. [Institut fuer Solare Energieversorgungstechnik (ISET), Kassel (Germany). Abt. fuer Anlagen- und Messtechnik

    1998-02-01

    The energetically optimal design of PV facades requires the consideration of many technical conditions (different elevations/orientations of modules; shading possibility; high and different module temperatures). It also requires the interface with architecture, civil and electrical engineering. To support this planning process, the software program PV-CAD was developed which rapidly calculates energy yield under conditions of inhomogeneous irradiance, shading, thermal behaviour of modules and electrical layout. PV-CAD is compatible with other civil and electrical engineering CAD programs and incorporates extensive databases (weather data; modules and inverter types). (orig.) [Deutsch] Fuer optimalen Energieertrag sind zahlreiche technische Randbedingungen bei der Auslegung einer Photovoltaik (PV)-Fassade zu beruecksichtigen (unterschiedliche Ausrichtungen/Neigungen der Module; moegliche Teilabschattung; hoehere und unterschiedliche Betriebstemperaturen). Installation und Betrieb einer PV-Fassade erfordern die Abstimmung zwischen Architektur, Bauwesen und Elektrotechnik. Zur Unterstuetzung der Planer wurde das Programm PV-CAD entwickelt, das den Energieertrag unter Beruecksichtigung von inhomogener Einstrahlung und Abschattung, Temperaturverhalten der Fassadenmodule sowie unterschiedlichen elektrischen Anlagenkonzepten schnell ermittelt; es fuegt sich nahtlos in CAD-Arbeitsumgebungen ein. (orig.)

  5. Machine Tool Software

    Science.gov (United States)

    1988-01-01

    A NASA-developed software package has played a part in technical education of students who major in Mechanical Engineering Technology at William Rainey Harper College. Professor Hack has been using (APT) Automatically Programmed Tool Software since 1969 in his CAD/CAM Computer Aided Design and Manufacturing curriculum. Professor Hack teaches the use of APT programming languages for control of metal cutting machines. Machine tool instructions are geometry definitions written in APT Language to constitute a "part program." The part program is processed by the machine tool. CAD/CAM students go from writing a program to cutting steel in the course of a semester.

  6. Cool-and Unusual-CAD Applications

    Science.gov (United States)

    Calhoun, Ken

    2004-01-01

    This article describes several very useful applications of AutoCAD that may lie outside the normal scope of application. AutoCAD commands used in this article are based on AutoCAD 2000I. The author and his students used a Hewlett Packard 750C DesignJet plotter for plotting. (Contains 5 figures and 5 photos.)

  7. AutoCAD 2015 and AutoCAD LT 2015

    CERN Document Server

    Gladfelter, Donnie

    2014-01-01

    Learn AutoCAD by example with this tutorial-based guide from Autodesk Official Press Whether you are just starting out or an experienced user wanting to brush up on your skills, this Autodesk Official Press book provides you with concise explanations, focused examples, and step-by-step instructions through a hands-on tutorial project that runs throughout the book. As you progress through the project, the book introduces you to the Microsoft Windows-based AutoCAD interface and then guides you through basic commands and creating drawings. A downloadable file is available from the website so that

  8. CAD-based automatic modeling method for Geant4 geometry model through MCAM

    International Nuclear Information System (INIS)

    Wang, D.; Nie, F.; Wang, G.; Long, P.; LV, Z.

    2013-01-01

    The full text of publication follows. Geant4 is a widely used Monte Carlo transport simulation package. Before calculating using Geant4, the calculation model need be established which could be described by using Geometry Description Markup Language (GDML) or C++ language. However, it is time-consuming and error-prone to manually describe the models by GDML. Automatic modeling methods have been developed recently, but there are some problems that exist in most present modeling programs, specially some of them were not accurate or adapted to specifically CAD format. To convert the GDML format models to CAD format accurately, a Geant4 Computer Aided Design (CAD) based modeling method was developed for automatically converting complex CAD geometry model into GDML geometry model. The essence of this method was dealing with CAD model represented with boundary representation (B-REP) and GDML model represented with constructive solid geometry (CSG). At first, CAD model was decomposed to several simple solids which had only one close shell. And then the simple solid was decomposed to convex shell set. Then corresponding GDML convex basic solids were generated by the boundary surfaces getting from the topological characteristic of a convex shell. After the generation of these solids, GDML model was accomplished with series boolean operations. This method was adopted in CAD/Image-based Automatic Modeling Program for Neutronics and Radiation Transport (MCAM), and tested with several models including the examples in Geant4 install package. The results showed that this method could convert standard CAD model accurately, and can be used for Geant4 automatic modeling. (authors)

  9. CAD: Designs on Business.

    Science.gov (United States)

    Milburn, Ken

    1988-01-01

    Provides a general review of the field of Computer-Aided Design Software including specific reviews of "Autosketch,""Generic CADD,""Drafix 1 Plus,""FastCAD," and "Autocad Release 9." Brief articles include "Blueprint for Generation,""CAD for Every Department,""Ideas…

  10. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.

    Science.gov (United States)

    Alp, Gülce; Murat, Sema; Yilmaz, Burak

    2018-01-28

    To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p CAD/CAM PMMA-based M (p CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.

  11. An Educational Exercise Examining the Role of Model Attributes on the Creation and Alteration of CAD Models

    Science.gov (United States)

    Johnson, Michael D.; Diwakaran, Ram Prasad

    2011-01-01

    Computer-aided design (CAD) is a ubiquitous tool that today's students will be expected to use proficiently for numerous engineering purposes. Taking full advantage of the features available in modern CAD programs requires that models are created in a manner that allows others to easily understand how they are organized and alter them in an…

  12. Ergonomics Perspective in Agricultural Research: A User-Centred Approach Using CAD and Digital Human Modeling (DHM) Technologies

    Science.gov (United States)

    Patel, Thaneswer; Sanjog, J.; Karmakar, Sougata

    2016-09-01

    Computer-aided Design (CAD) and Digital Human Modeling (DHM) (specialized CAD software for virtual human representation) technologies endow unique opportunities to incorporate human factors pro-actively in design development. Challenges of enhancing agricultural productivity through improvement of agricultural tools/machineries and better human-machine compatibility can be ensured by adoption of these modern technologies. Objectives of present work are to provide the detailed scenario of CAD and DHM applications in agricultural sector; and finding out means for wide adoption of these technologies for design and development of cost-effective, user-friendly, efficient and safe agricultural tools/equipment and operator's workplace. Extensive literature review has been conducted for systematic segregation and representation of available information towards drawing inferences. Although applications of various CAD software have momentum in agricultural research particularly for design and manufacturing of agricultural equipment/machinery, use of DHM is still at its infancy in this sector. Current review discusses about reasons of less adoption of these technologies in agricultural sector and steps to be taken for their wide adoption. It also suggests possible future research directions to come up with better ergonomic design strategies for improvement of agricultural equipment/machines and workstations through application of CAD and DHM.

  13. Effectiveness and efficiency of a CAD/CAM orthodontic bracket system.

    Science.gov (United States)

    Brown, Matthew W; Koroluk, Lorne; Ko, Ching-Chang; Zhang, Kai; Chen, Mengqi; Nguyen, Tung

    2015-12-01

    The first straight-wire appliance was introduced over 40 years ago to increase the consistency and efficiency of orthodontic treatment. More recently, computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been used to create individualized orthodontic appliances. The purpose of this study was to investigate the clinical effectiveness and efficiency of CAD/CAM customized orthodontic appliances compared with direct and indirect bonded stock orthodontic brackets. This retrospective study included 3 treatment groups: group 1 patients were direct bonded with self-ligating appliances, group 2 patients were indirect bonded with self-ligating appliances, and group 3 patients were indirect bonded with CAD/CAM self-ligating appliances. Complete pretreatment and posttreatment records were obtained for all patients. The American Board of Orthodontics (ABO) Discrepancy Index was used to evaluate the pretreatment records, and the posttreatment outcomes were analyzed using the ABO Cast-Radiograph Evaluation. All data collection and analysis were completed by 1 evaluator. There were no statistically significant differences in the ABO Discrepancy Index or the ABO Cast-Radiograph Evaluation among the groups. Treatment times for the 3 groups were significantly different; the CAD/CAM group was the shortest at 13.8 ± 3.4 months, compared with 21.9 ± 5.0 and 16.9 ± 4.1 months for the direct bonded and indirect bonded groups, respectively. The number of treatment appointments for the CAD/CAM group was significantly fewer than for the direct bonded group. The CAD/CAM orthodontic bracket system evaluated in this study was as effective in treatment outcome measures as were standard brackets bonded both directly and indirectly. The CAD/CAM appliance was more efficient in regard to treatment duration, although the decrease in total archwire appointments was minimal. Further investigation is needed to better quantify the clinical benefits of CAD/CAM orthodontic

  14. A CAD system and quality assurance protocol for bone age assessment utilizing digital hand atlas

    Science.gov (United States)

    Gertych, Arakadiusz; Zhang, Aifeng; Ferrara, Benjamin; Liu, Brent J.

    2007-03-01

    Determination of bone age assessment (BAA) in pediatric radiology is a task based on detailed analysis of patient's left hand X-ray. The current standard utilized in clinical practice relies on a subjective comparison of the hand with patterns in the book atlas. The computerized approach to BAA (CBAA) utilizes automatic analysis of the regions of interest in the hand image. This procedure is followed by extraction of quantitative features sensitive to skeletal development that are further converted to a bone age value utilizing knowledge from the digital hand atlas (DHA). This also allows providing BAA results resembling current clinical approach. All developed methodologies have been combined into one CAD module with a graphical user interface (GUI). CBAA can also improve the statistical and analytical accuracy based on a clinical work-flow analysis. For this purpose a quality assurance protocol (QAP) has been developed. Implementation of the QAP helped to make the CAD more robust and find images that cannot meet conditions required by DHA standards. Moreover, the entire CAD-DHA system may gain further benefits if clinical acquisition protocol is modified. The goal of this study is to present the performance improvement of the overall CAD-DHA system with QAP and the comparison of the CAD results with chronological age of 1390 normal subjects from the DHA. The CAD workstation can process images from local image database or from a PACS server.

  15. Model-Based Engineering and Manufacturing CAD/CAM Benchmark

    International Nuclear Information System (INIS)

    Domm, T.D.; Underwood, R.S.

    1999-01-01

    than a single computer-aided manufacturing (CAM) system. The Inteznet was a technology that all companies were considering to either transport information more easily throughout the corporation or as a conduit for business, as the small firm was doing Successfully. Because PrdEngineer is the de facto CAD standard fbr the NWC, the Benchmark Team targeted companies using Parametric Technology Corporation (PTC) software tools. Most of the companies used Pm'Engineer for design to some degree, but found the PTC CAM product, PdManufacture lacking as compared to alternate CAM solutions. All of the companies visited found the data exchange between CAD/CAM systems problematic. It was apparent that these companies were trying to consolidate their software tools to reduce translation but had not been able to do so because no single solution had all the needed capabilities. In regard to organizational structure and human resources, two companies were found to be using product or program teams. These teams consisted of the technical staff capable of completing the entire task and were xmintained throughout the project. This same strategy was evident at another of the companies but with more mobility of members. For all companies visited except the small work structure breakdown and responsibility were essentially the same as Y-12's at this time. The functions of numerical control (NC), desi and process planning were separate and distinct. The team made numerous recommendations that are detailed in the report

  16. Design Automation Using Script Languages. High-Level CAD Templates in Non-Parametric Programs

    Science.gov (United States)

    Moreno, R.; Bazán, A. M.

    2017-10-01

    The main purpose of this work is to study the advantages offered by the application of traditional techniques of technical drawing in processes for automation of the design, with non-parametric CAD programs, provided with scripting languages. Given that an example drawing can be solved with traditional step-by-step detailed procedures, is possible to do the same with CAD applications and to generalize it later, incorporating references. In today’s modern CAD applications, there are striking absences of solutions for building engineering: oblique projections (military and cavalier), 3D modelling of complex stairs, roofs, furniture, and so on. The use of geometric references (using variables in script languages) and their incorporation into high-level CAD templates allows the automation of processes. Instead of repeatedly creating similar designs or modifying their data, users should be able to use these templates to generate future variations of the same design. This paper presents the automation process of several complex drawing examples based on CAD script files aided with parametric geometry calculation tools. The proposed method allows us to solve complex geometry designs not currently incorporated in the current CAD applications and to subsequently create other new derivatives without user intervention. Automation in the generation of complex designs not only saves time but also increases the quality of the presentations and reduces the possibility of human errors.

  17. Strategies for the Curation of CAD Engineering Models

    Directory of Open Access Journals (Sweden)

    Manjula Patel

    2009-06-01

    Full Text Available Normal 0 Product Lifecycle Management (PLM has become increasingly important in the engineering community over the last decade or so, due to the globalisation of markets and the rising popularity of products provided as services. It demands the efficient capture, representation, organisation, retrieval and reuse of product data over its entire life. Simultaneously, there is now a much greater reliance on CAD models for communicating designs to manufacturers, builders, maintenance crews and regulators, and for definitively expressing designs. Creating the engineering record digitally, however, presents problems not only for its long-term maintenance and accessibility - due in part to the rapid obsolescence of the hardware, software and file formats involved - but also for recording the evolution of designs, artefacts and products. We examine the curation and preservation requirements in PLM and suggest ways of alleviating the problems of sustaining CAD engineering models through the use of lightweight formats, layered annotation and the collection of Representation Information as defined in the Open Archival Information System (OAIS Reference Model.  We describe two tools which have been specifically developed to aid in the curation of CAD engineering models in the context of PLM: Lightweight Models with Multilayered Annotation (LiMMA and a Registry/Repository of Representation Information for Engineering (RRoRIfE.

  18. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006 - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collabora- tion avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  19. Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance

    International Nuclear Information System (INIS)

    Roos, Justus E.; Paik, David; Olsen, David; Liu, Emily G.; Leung, Ann N.; Mindelzun, Robert; Choudhury, Kingshuk R.; Napel, Sandy; Rubin, Geoffrey D.; Chow, Lawrence C.; Naidich, David P.

    2010-01-01

    The diagnostic performance of radiologists using incremental CAD assistance for lung nodule detection on CT and their temporal variation in performance during CAD evaluation was assessed. CAD was applied to 20 chest multidetector-row computed tomography (MDCT) scans containing 190 non-calcified ≥3-mm nodules. After free search, three radiologists independently evaluated a maximum of up to 50 CAD detections/patient. Multiple free-response ROC curves were generated for free search and successive CAD evaluation, by incrementally adding CAD detections one at a time to the radiologists' performance. The sensitivity for free search was 53% (range, 44%-59%) at 1.15 false positives (FP)/patient and increased with CAD to 69% (range, 59-82%) at 1.45 FP/patient. CAD evaluation initially resulted in a sharp rise in sensitivity of 14% with a minimal increase in FP over a time period of 100 s, followed by flattening of the sensitivity increase to only 2%. This transition resulted from a greater prevalence of true positive (TP) versus FP detections at early CAD evaluation and not by a temporal change in readers' performance. The time spent for TP (9.5 s ± 4.5 s) and false negative (FN) (8.4 s ± 6.7 s) detections was similar; FP decisions took two- to three-times longer (14.4 s ± 8.7 s) than true negative (TN) decisions (4.7 s ± 1.3 s). When CAD output is ordered by CAD score, an initial period of rapid performance improvement slows significantly over time because of non-uniformity in the distribution of TP CAD output and not to a changing reader performance over time. (orig.)

  20. Flexural resistance of Cerec CAD/CAM system ceramic blocks. Part 2: Outsourcing materials.

    Science.gov (United States)

    Sedda, Maurizio; Vichi, Alessandro; Del Siena, Francesco; Louca, Chris; Ferrari, Marco

    2014-02-01

    To test different Cerec CAD/CAM system ceramic blocks, comparing mean flexural strength (sigma), Weibull modulus (m), and Weibull characteristic strength (sigma0) in an ISO standardized set-up. Following the recent ISO Standard (ISO 6872:2008), 11 types of ceramic blocks were tested: IPS e.max CAD MO, IPS e.max CAD LT and IPS e.max CAD HT (lithium disilicate glass-ceramic); In-Ceram SPINELL, In-Ceram Alumina and In-Ceram Zirconia (glass-infiltrated materials); inCoris AL and In-Ceram AL (densely sintered alumina); In-Ceram YZ, IPS e.max Zir-CAD and inCoris ZI (densely sintered zirconia). Specimens were cut out from ceramic blocks, finished, crystallized/infiltrated/sintered, polished, and tested in a three-point bending test apparatus. Flexural strength, Weibull characteristic strength, and Weibull modulus were obtained. A statistically significant difference was found (P ceramic (sigma = 272.6 +/- 376.8 MPa, m = 6.2 +/- 11.3, sigma0 = 294.0 +/- 394.1 MPa) and densely sintered alumina (sigma = 441.8 +/- 541.6 MPa, m = 11.9 +/- 19.0, sigma0 = 454.2 +/- 565.2 MPa). No statistically significant difference was found (P = 0.254) in glass infiltrated materials (sigma = 376.9 +/- 405.5 MPa, m = 7.5 +/- 11.5, sigma0 = 393.7 +/- 427.0 MPa). No statistically significant difference was found (P = 0.160) in densely sintered zirconia (sigma = 1,060.8 +/- 1,227.8 MPa, m = 5.8 +/- 7.4, sigma0 = 1,002.4 +/- 1,171.0 MPa). Not all the materials tested fulfilled the requirements for the clinical indications recommended by the manufacturer.

  1. Improving the radiologist–CAD interaction: designing for appropriate trust

    International Nuclear Information System (INIS)

    Jorritsma, W.; Cnossen, F.; Ooijen, P.M.A. van

    2015-01-01

    Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist–CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the interaction between radiologists and the CAD system is not optimal. An important factor in the interaction between humans and automated aids (such as CAD) is trust. Suboptimal performance of the human–automation team is often caused by an inappropriate level of trust in the automation. In this review, we examine the role of trust in the radiologist–CAD interaction and suggest ways to improve the output of the CAD system so that it allows radiologists to calibrate their trust in the CAD system more effectively. Observer studies of the CAD systems show that radiologists often have an inappropriate level of trust in the CAD system. They sometimes under-trust CAD, thereby reducing its potential benefits, and sometimes over-trust it, leading to diagnostic errors they would not have made without CAD. Based on the literature on trust in human–automation interaction and the results of CAD observer studies, we have identified four ways to improve the output of CAD so that it allows radiologists to form a more appropriate level of trust in CAD. Designing CAD systems for appropriate trust is important and can improve the performance of the radiologist–CAD team. Future CAD research and development should acknowledge the importance of the radiologist–CAD interaction, and specifically the role of trust therein, in order to create the perfect artificial partner for the radiologist. This review focuses on the role of trust in the radiologist–CAD interaction. The aim of the review is to encourage CAD developers to design for appropriate trust and thereby improve the performance of the radiologist–CAD team. - Highlights: • Radiologists often have an inappropriate

  2. Fra form-Z til AutoCad

    DEFF Research Database (Denmark)

    Jensen, Henrik

    2003-01-01

    Dette kursus er lavet for at forberede de studerende til deres tegnestuepraktik, og dets indhold er planlagt i samarbejde med tegnestuerne. I 2003 var form-Z Arkitektskolens grundlæggende CAD-program; men på tegnestuerne arbejde man med AutoCad. Kurset er opbygget over CAD Clasic skabelonen (se min...

  3. An Analysis of Computer Aided Design (CAD) Packages Used at MSFC for the Recent Initiative to Integrate Engineering Activities

    Science.gov (United States)

    Smith, Leigh M.; Parker, Nelson C. (Technical Monitor)

    2002-01-01

    This paper analyzes the use of Computer Aided Design (CAD) packages at NASA's Marshall Space Flight Center (MSFC). It examines the effectiveness of recent efforts to standardize CAD practices across MSFC engineering activities. An assessment of the roles played by management, designers, analysts, and manufacturers in this initiative will be explored. Finally, solutions are presented for better integration of CAD across MSFC in the future.

  4. Toward clinically usable CAD for lung cancer screening with computed tomography

    International Nuclear Information System (INIS)

    Brown, Matthew S.; Lo, Pechin; Goldin, Jonathan G.; Barnoy, Eran; Kim, Grace Hyun J.; McNitt-Gray, Michael F.; Aberle, Denise R.

    2014-01-01

    The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. The test set comprised thin-section CT scans from 108 LIDC subjects. The median (±IQR) sensitivity per subject was 100 (±37.5) for nodules ≥ 4 mm and 100 (±8.33) for nodules ≥ 8 mm. The corresponding false positive rates were 0 (±2.0) and 0 (±1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality. (orig.)

  5. Toward clinically usable CAD for lung cancer screening with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Matthew S.; Lo, Pechin; Goldin, Jonathan G.; Barnoy, Eran; Kim, Grace Hyun J.; McNitt-Gray, Michael F.; Aberle, Denise R. [David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, CA (United States)

    2014-11-15

    The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. The test set comprised thin-section CT scans from 108 LIDC subjects. The median (±IQR) sensitivity per subject was 100 (±37.5) for nodules ≥ 4 mm and 100 (±8.33) for nodules ≥ 8 mm. The corresponding false positive rates were 0 (±2.0) and 0 (±1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality. (orig.)

  6. Initial CAD investigations for NET

    International Nuclear Information System (INIS)

    Katz, F.; Leinemann, K.; Ludwig, A.; Marek, U.; Olbrich, W.; Schlechtendahl, E.G.

    1985-11-01

    This report summarizes the work done under contract no. 164/84-7/FU-D-/NET between the Commission of the European Communities and KfK during the period from June 1, 1984, through May 31, 1985. The following topics are covered in this report: Initial modelling of NET version NET2A, CAD system extension for remote handling studies, analysis of the CAD information structure, work related to the transfer of CAD information between KfK and the NET team. (orig.) [de

  7. TopoCad - A unified system for geospatial data and services

    Science.gov (United States)

    Felus, Y. A.; Sagi, Y.; Regev, R.; Keinan, E.

    2013-10-01

    "E-government" is a leading trend in public sector activities in recent years. The Survey of Israel set as a vision to provide all of its services and datasets online. The TopoCad system is the latest software tool developed in order to unify a number of services and databases into one on-line and user friendly system. The TopoCad system is based on Web 1.0 technology; hence the customer is only a consumer of data. All data and services are accessible for the surveyors and geo-information professional in an easy and comfortable way. The future lies in Web 2.0 and Web 3.0 technologies through which professionals can upload their own data for quality control and future assimilation with the national database. A key issue in the development of this complex system was to implement a simple and easy (comfortable) user experience (UX). The user interface employs natural language dialog box in order to understand the user requirements. The system then links spatial data with alpha-numeric data in a flawless manner. The operation of the TopoCad requires no user guide or training. It is intuitive and self-taught. The system utilizes semantic engines and machine understanding technologies to link records from diverse databases in a meaningful way. Thus, the next generation of TopoCad will include five main modules: users and projects information, coordinates transformations and calculations services, geospatial data quality control, linking governmental systems and databases, smart forms and applications. The article describes the first stage of the TopoCad system and gives an overview of its future development.

  8. Coronary artery disease reporting and data system (CAD-RADSTM): Inter-observer agreement for assessment categories and modifiers.

    Science.gov (United States)

    Maroules, Christopher D; Hamilton-Craig, Christian; Branch, Kelley; Lee, James; Cury, Roberto C; Maurovich-Horvat, Pál; Rubinshtein, Ronen; Thomas, Dustin; Williams, Michelle; Guo, Yanshu; Cury, Ricardo C

    The Coronary Artery Disease Reporting and Data System (CAD-RADS) provides a lexicon and standardized reporting system for coronary CT angiography. To evaluate inter-observer agreement of the CAD-RADS among an panel of early career and expert readers. Four early career and four expert cardiac imaging readers prospectively and independently evaluated 50 coronary CT angiography cases using the CAD-RADS lexicon. All readers assessed image quality using a five-point Likert scale, with mean Likert score ≥4 designating high image quality, and CAD-RADS assessment categories and modifiers were assessed using intra-class correlation (ICC) and Fleiss' Kappa (κ).The impact of reader experience and image quality on inter-observer agreement was also examined. Inter-observer agreement for CAD-RADS assessment categories was excellent (ICC 0.958, 95% CI 0.938-0.974, p CAD-RADS assessment categories and modifiers is excellent, except for high-risk plaque (modifier V) which demonstrates fair agreement. These results suggest CAD-RADS is feasible for clinical implementation. Copyright © 2017. Published by Elsevier Inc.

  9. Present state of computer-aided diagnosis (CAD) development

    International Nuclear Information System (INIS)

    Fujita, Hiroshi

    2007-01-01

    Topics of computer-aided detection (CAD) are reviewed. Commercially available, Food and Drug Administration (FDA)-approved CAD systems are for fields of breast cancer (mammography), chest (flat X-ray and CT imaging) and colon (polyp detection). In Japan, only mammography CAD is approved. Efficacy of CAD is controversial, for which reliable database is important, and its construction is under development in various medical fields. Digitalized image is now popularized, which conceivably leads to improve the cost-effectiveness of diagnosis with CAD. For incentive, approval for health insurance would be the case as seen in the increased CAD sale by R2 Technology Co., and MHLW actually assists facilities to introduce the reading-aid system of mammography by sharing a half of its cost. There are 2 big projects for CAD study supported by MECSST, which the author concerns. One is the development of diagnostic aid for the multi-dimensional medical images where the multi-organ, multi-disease CAD system is considered. The other involves the CAD in brain MRI, in breast US and in eyeground picture. It is not in so far future for patients and doctors to fully enjoy the benefit of CAD. (R.T.)

  10. Suunnitteluautomaatio CAD-ohjelmissa

    OpenAIRE

    Anttila, Juho

    2010-01-01

    Tässä työssä tutkittiin suunnitteluautomaation mahdollisuuksia cad-ohjelmissa. Työtä varten perehdyttiin useampaan cad-ohjelmaan ja tehtiin suurehko automaatti Vertex G4 alustalle, jonka kokemuksiin työn pohdinta pitkälti perustuu. Työ etenee yleisestä työkalujen esittelystä automatisoinnin teoriaan. Teoriassa pohditaan erilaisia tapoja ja tasoja miten automatisointia voidaan toteuttaa. Työn aihe oli kiinnostava, koska aiheesta on tehty melko vähän teoksia. Teoriapohdiskelun ohella esitettii...

  11. The microcomputer-based expert system in CAD-PV

    International Nuclear Information System (INIS)

    Wang, Y.; Qin, S.

    1987-01-01

    As a branch of artificial intelligence, expert system has been revealed day after day in more and more engineering scopes since the successful applications of MYCIN in diagnosis and DENDRAL in the molecular structure of organic compounds etc.. But in the design scope of pressure vessel, as we know, only a few papers have so far been published with respect to the expert system. The necessity and feasibility of accompanying CAD-PV with expert system attracted more scholars to engage in. Although many countries, including China, have regularized the design standards or codes for pressure vessel, but of which no one can solve all of the problems concerning the various practical occasions and experiences. In general, the more domain knowledges a design engineer possesses of, the better decision will be made by him. By virtue of the expert system any less experienced engineer could make the optimum decision in design as well as a skilled senior engineer in addition to the application of design code. It is the due significance for developing high level expert system as an intelligence assistant in the plan option of CAD-PV. In this paper we attempt to introduce a specified software JACKPV used in the design procedure of jacketed pressure vessel as an intelligence front in CAD-PV. JACKPV consists of the function of expert system based on the personal computer IBM-PC/XT with the language PASCAL in its program. It was proved that an ordinary CAD software could be effectively improved while equipped with expert system. (orig.)

  12. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006

    - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium, Bât 593 Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collaboration avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  13. AutoCAD Civil 3D 2014 essentials

    CERN Document Server

    Chappell, Eric

    2013-01-01

    Quickly learn essential Civil 3D tools and techniques Get a thorough introduction to AutoCAD Civil 3D, the industry-leading engineering software used to design roads, highways, subdivisions, drainage and sewer systems, and more. This Autodesk Official Press book is a unique learning resource that features concise, straightforward explanations and real-world, hands-on exercises and tutorials. With compelling full-color screenshots and approachable exercises that demonstrate core features and functions, the book helps you gain understanding and confidence as you master this premiere

  14. DESIGNING AN EFFECTIVE INTERSECTION USING CAD ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    CRISAN George-Horea

    2017-05-01

    Full Text Available Ensuring the safety and streamline in road traffic are very important aims, with regard to the nowadays people mobility level. Road infrastructure is an essential element that can meet these requirements. Thus, it is proposed to develop an effective model of intersection by using CAD software tools. This type of intersection can be successfully used on almost any category of roads, increasing road traffic safety, reducing passing times through the intersection and in the same time, reducing conflict points and increase the intersection capacity.

  15. 64006 CAD i Byggesektoren. Grundkursus

    DEFF Research Database (Denmark)

    Borchersen, Egil

    1998-01-01

    Overview on Computer Aided Design in Civil Engineering and introduction to AutoCAD version 13, layers, colours, blocks, attributes.......Overview on Computer Aided Design in Civil Engineering and introduction to AutoCAD version 13, layers, colours, blocks, attributes....

  16. AutoCAD platform customization user interface and beyond

    CERN Document Server

    Ambrosius, Lee

    2014-01-01

    Make AutoCAD your own with powerful personalization options Options for AutoCAD customization are typically the domain of administrators, but savvy users can perform their own customizations to personalize AutoCAD. Until recently, most users never thought to customize the AutoCAD platform to meet their specific needs, instead leaving it to administrators. If you are an AutoCAD user who wants to ramp up personalization options in your favorite software, AutoCAD Platform Customization: User Interface and Beyond is the perfect resource for you. Author Lee Ambrosius is recognized as a leader in Au

  17. The Enzyme Activity and Substrate Specificity of Two Major Cinnamyl Alcohol Dehydrogenases in Sorghum (Sorghum bicolor), SbCAD2 and SbCAD4.

    Science.gov (United States)

    Jun, Se-Young; Walker, Alexander M; Kim, Hoon; Ralph, John; Vermerris, Wilfred; Sattler, Scott E; Kang, ChulHee

    2017-08-01

    Cinnamyl alcohol dehydrogenase (CAD) catalyzes the final step in monolignol biosynthesis, reducing sinapaldehyde, coniferaldehyde, and p -coumaraldehyde to their corresponding alcohols in an NADPH-dependent manner. Because of its terminal location in monolignol biosynthesis, the variation in substrate specificity and activity of CAD can result in significant changes in overall composition and amount of lignin. Our in-depth characterization of two major CAD isoforms, SbCAD2 (Brown midrib 6 [bmr6]) and SbCAD4, in lignifying tissues of sorghum ( Sorghum bicolor ), a strategic plant for generating renewable chemicals and fuels, indicates their similarity in both structure and activity to Arabidopsis ( Arabidopsis thaliana ) CAD5 and Populus tremuloides sinapyl alcohol dehydrogenase, respectively. This first crystal structure of a monocot CAD combined with enzyme kinetic data and a catalytic model supported by site-directed mutagenesis allows full comparison with dicot CADs and elucidates the potential signature sequence for their substrate specificity and activity. The L119W/G301F-SbCAD4 double mutant displayed its substrate preference in the order coniferaldehyde > p -coumaraldehyde > sinapaldehyde, with higher catalytic efficiency than that of both wild-type SbCAD4 and SbCAD2. As SbCAD4 is the only major CAD isoform in bmr6 mutants, replacing SbCAD4 with L119W/G301F-SbCAD4 in bmr6 plants could produce a phenotype that is more amenable to biomass processing. © 2017 American Society of Plant Biologists. All Rights Reserved.

  18. New orthopaedic implant management tool for computer-assisted planning, navigation, and simulation: from implant CAD files to a standardized XML-based implant database.

    Science.gov (United States)

    Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G

    2005-01-01

    Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap

  19. RayTrace: A Simplified Ray Tracing Software for use in AutoCad

    DEFF Research Database (Denmark)

    Reimann, Gregers Peter; Tang, C.K.

    2005-01-01

    A design aid tool for testing and development of daylighting systems was developed. A simplified ray tracing software was programmed in Lisp for AutoCad. Only fully specularly reflective, fully transparent and fully absorbant surfaces can be defined in the software. The software is therefore best...

  20. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    Science.gov (United States)

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD

  1. Viewing CAD Drawings on the Internet

    Science.gov (United States)

    Schwendau, Mark

    2004-01-01

    Computer aided design (CAD) has been producing 3-D models for years. AutoCAD software is frequently used to create sophisticated 3-D models. These CAD files can be exported as 3DS files for import into Autodesk's 3-D Studio Viz. In this program, the user can render and modify the 3-D model before exporting it out as a WRL (world file hyperlinked)…

  2. A voxel visualization and analysis system based on AutoCAD

    Science.gov (United States)

    Marschallinger, Robert

    1996-05-01

    A collection of AutoLISP programs is presented which enable the visualization and analysis of voxel models by AutoCAD rel. 12/rel. 13. The programs serve as an interactive, graphical front end for manipulating the results of three-dimensional modeling software producing block estimation data. ASCII data files describing geometry and attributes per estimation block are imported and stored as a voxel array. Each voxel may contain multiple attributes, therefore different parameters may be incorporated in one voxel array. Voxel classification is implemented on a layer basis providing flexible treatment of voxel classes such as recoloring, peeling, or volumetry. A versatile clipping tool enables slicing voxel arrays according to combinations of three perpendicular clipping planes. The programs feature an up-to-date, graphical user interface for user-friendly operation by non AutoCAD specialists.

  3. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv

    Energy Technology Data Exchange (ETDEWEB)

    Messerli, Michael, E-mail: Michael.Messerli@usz.ch [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Kluckert, Thomas; Knitel, Meinhard [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Rengier, Fabian [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg (Germany); Warschkow, René [Department of Surgery, Cantonal Hospital St. Gallen (Switzerland); Alkadhi, Hatem [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich (Switzerland); Leschka, Sebastian [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich (Switzerland); Wildermuth, Simon; Bauer, Ralf W. [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland)

    2016-12-15

    Highlights: • Computer-aided detection (CAD) of solid pulmonary nodules was compared in 202 patients in standard dose and ultralow dose CT. • The per–nodule sensitivity of CAD was 70% in standard dose CT and 68% in ultralow dose CT. • The per–nodule sensitivity of CAD in standard dose CT was similar to ultralow dose CT in all size subgroups (all p > 0.05). • Adding CAD markings in ultralow dose CT significantly improved the sensitivity of two radiologists from 77% to 88% and from 66% to 79%, respectively. • CAD can serve as an excellent second reader for nodule detection in CT even at dose levels similar to chest X-ray. - Abstract: Objectives: To determine the value of computer-aided detection (CAD) for solid pulmonary nodules in ultralow radiation dose single-energy computed tomography (CT) of the chest using third-generation dual-source CT at 100 kV and fixed tube current at 70 mAs with tin filtration. Methods: 202 consecutive patients undergoing clinically indicated standard dose chest CT (1.8 ± 0.7 mSv) were prospectively included and scanned with an additional ultralow dose CT (0.13 ± 0.01 mSv) in the same session. Standard of reference (SOR) was established by consensus reading of standard dose CT by two radiologists. CAD was performed in standard dose and ultralow dose CT with two different reconstruction kernels. CAD detection rate of nodules was evaluated including subgroups of different nodule sizes (<5, 5–7, >7 mm). Sensitivity was further analysed in multivariable mixed effects logistic regression. Results: The SOR included 279 solid nodules (mean diameter 4.3 ± 3.4 mm, range 1–24 mm). There was no significant difference in per–nodule sensitivity of CAD in standard dose with 70% compared to 68% in ultralow dose CT both overall and in different size subgroups (all p > 0.05). CAD led to a significant increase of sensitivity for both radiologists reading the ultralow dose CT scans (all p < 0.001). In multivariable analysis, the use

  4. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv

    International Nuclear Information System (INIS)

    Messerli, Michael; Kluckert, Thomas; Knitel, Meinhard; Rengier, Fabian; Warschkow, René; Alkadhi, Hatem; Leschka, Sebastian; Wildermuth, Simon; Bauer, Ralf W.

    2016-01-01

    Highlights: • Computer-aided detection (CAD) of solid pulmonary nodules was compared in 202 patients in standard dose and ultralow dose CT. • The per–nodule sensitivity of CAD was 70% in standard dose CT and 68% in ultralow dose CT. • The per–nodule sensitivity of CAD in standard dose CT was similar to ultralow dose CT in all size subgroups (all p > 0.05). • Adding CAD markings in ultralow dose CT significantly improved the sensitivity of two radiologists from 77% to 88% and from 66% to 79%, respectively. • CAD can serve as an excellent second reader for nodule detection in CT even at dose levels similar to chest X-ray. - Abstract: Objectives: To determine the value of computer-aided detection (CAD) for solid pulmonary nodules in ultralow radiation dose single-energy computed tomography (CT) of the chest using third-generation dual-source CT at 100 kV and fixed tube current at 70 mAs with tin filtration. Methods: 202 consecutive patients undergoing clinically indicated standard dose chest CT (1.8 ± 0.7 mSv) were prospectively included and scanned with an additional ultralow dose CT (0.13 ± 0.01 mSv) in the same session. Standard of reference (SOR) was established by consensus reading of standard dose CT by two radiologists. CAD was performed in standard dose and ultralow dose CT with two different reconstruction kernels. CAD detection rate of nodules was evaluated including subgroups of different nodule sizes (<5, 5–7, >7 mm). Sensitivity was further analysed in multivariable mixed effects logistic regression. Results: The SOR included 279 solid nodules (mean diameter 4.3 ± 3.4 mm, range 1–24 mm). There was no significant difference in per–nodule sensitivity of CAD in standard dose with 70% compared to 68% in ultralow dose CT both overall and in different size subgroups (all p > 0.05). CAD led to a significant increase of sensitivity for both radiologists reading the ultralow dose CT scans (all p < 0.001). In multivariable analysis, the use

  5. Computing Mass Properties From AutoCAD

    Science.gov (United States)

    Jones, A.

    1990-01-01

    Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).

  6. Line Generalization and AutoCAD Map

    Directory of Open Access Journals (Sweden)

    Nada Vučetić

    2001-01-01

    Full Text Available The paper offers the results of original research made on the application of AutoCAD Map in line generalisation. The differences and similarities have been found out between the Douglas-Peucker method and the method of line simplification that is incorporated in AutoCAD Map. There have been also the inaccuracies found out in AutoCAD Map manual relating to the issues of buffer width and tolerance, and the line width before and after simplification. The paper gives recommendations about pseudo nodes dissolving. It has been noticed that AutoCAD Map simplification method is not independent of the order of points. The application of the method is illustrated by an example of coastal line of Istria.

  7. Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques

    Science.gov (United States)

    Vojdani, M; Torabi, K; Farjood, E; Khaledi, AAR

    2013-01-01

    Statement of Problem: Metal-ceramic crowns are most commonly used as the complete coverage restorations in clinical daily use. Disadvantages of conventional hand-made wax-patterns introduce some alternative ways by means of CAD/CAM technologies. Purpose: This study compares the marginal and internal fit of copings cast from CAD/CAM and conventional fabricated wax-patterns. Materials and Method: Twenty-four standardized brass dies were prepared and randomly divided into 2 groups according to the wax-patterns fabrication method (CAD/CAM technique and conventional method) (n=12). All the wax-patterns were fabricated in a standard fashion by means of contour, thickness and internal relief (M1-M12: representative of CAD/CAM group, C1-C12: representative of conventional group). CAD/CAM milling machine (Cori TEC 340i; imes-icore GmbH, Eiterfeld, Germany) was used to fabricate the CAD/CAM group wax-patterns. The copings cast from 24 wax-patterns were cemented to the corresponding dies. For all the coping-die assemblies cross-sectional technique was used to evaluate the marginal and internal fit at 15 points. The Student’s t- test was used for statistical analysis (α=0.05). Results: The overall mean (SD) for absolute marginal discrepancy (AMD) was 254.46 (25.10) um for CAD/CAM group and 88.08(10.67) um for conventional group (control). The overall mean of internal gap total (IGT) was 110.77(5.92) um for CAD/CAM group and 76.90 (10.17) um for conventional group. The Student’s t-test revealed significant differences between 2 groups. Marginal and internal gaps were found to be significantly higher at all measured areas in CAD/CAM group than conventional group (pmarginal and internal fit than CAD/CAM (machine-milled) technique. All the factors for 2 groups were standardized except wax pattern fabrication technique, therefore, only the conventional group results in copings with clinically acceptable margins of less than 120um. PMID:24724133

  8. Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism.

    Science.gov (United States)

    Buhmann, Sonja; Herzog, Peter; Liang, Jin; Wolf, Mathias; Salganicoff, Marcos; Kirchhoff, Chlodwig; Reiser, Maximilian; Becker, Christoph H

    2007-06-01

    To evaluate the performance of a prototype computer-aided diagnosis (CAD) tool using artificial intelligence techniques for the detection of pulmonary embolism (PE) and the possible benefit for general radiologists. Forty multidetector row computed tomography datasets (16/64- channel scanner) using 100 kVp, 100 mAs effective/slice, and 1-mm axial reformats in a low-frequency reconstruction kernel were evaluated. A total of 80 mL iodinated contrast material was injected at a flow rate of 5 mL/seconds. Primarily, six general radiologists marked any PE using a commercially available lung evaluation software with simultaneous, automatic processing by CAD in the background. An expert panel consisting of two chest radiologists analyzed all PE marks from the readers and CAD, also searching for additional finding primarily missed by both, forming the ground truth. The ground truth consisted of 212 emboli. Of these, 65 (31%) were centrally and 147 (69%) were peripherally located. The readers detected 157/212 emboli (74%) leading to a sensitivity of 97% (63/65) for central and 70% (103/147) for peripheral emboli with 9 false-positive findings. CAD detected 168/212 emboli (79%), reaching a sensitivity of 74% for central (48/65) and 82%(120/147) for peripheral emboli. A total of 154 CAD candidates were considered as false positives, yielding an average of 3.85 false positives/case. The CAD software showed a sensitivity comparable to that of the general radiologists, but with more false positives. CAD detection of findings incremental to the radiologists suggests benefit when used as a second reader. Future versions of CAD have the potential to further increase clinical benefit by improving sensitivity and reducing false marks.

  9. PorkCAD: Case study of the design of a pork product prototyper

    DEFF Research Database (Denmark)

    Laursen, Lasse Farnung; Bærentzen, J. Andreas; Igarashi, T.

    2013-01-01

    the usability of porkCAD, we tested it with personnel from the pork industry, using two different controller interfaces, one being a traditional mouse and keyboard input, and the other a six degrees of freedom haptic feedback device. The accurate depiction of pig anatomy guided trained professionals to re......-create standardized pig products using porkCAD. The quantitative results of the usability test with sales personnel did not lean significantly in favor of either interface. Since one interface was extremely well known and the other highly unfamiliar, the fact that users did not express a clear preference...

  10. BUILDING A PERGOLA IN CAD SYSTEMS

    Directory of Open Access Journals (Sweden)

    PRUNA Liviu

    2017-05-01

    Full Text Available In this paper the authors present a study and the conclusions they reached, regarding the possibility to automatically representing a pergola, when a CAD system is used. Also, a computer program, made by the authors is presented. This software was named Pergola and it offer the opportunity to sketch a pergola which cover a rectangular or circular area, when using the AutoCAD Architecture or AutoCAD computer program.

  11. CAD Skills Increased through Multicultural Design Project

    Science.gov (United States)

    Clemons, Stephanie

    2006-01-01

    This article discusses how students in a college-entry-level CAD course researched four generations of their family histories and documented cultural and symbolic influences within their family backgrounds. AutoCAD software was then used to manipulate those cultural and symbolic images to create the design for a multicultural area rug. AutoCAD was…

  12. The cinnamyl alcohol dehydrogenase (CAD gene family in flax (Linum usitatissimum L.: Insight from expression profiling of cads induced by elicitors in cultured flax cells

    Directory of Open Access Journals (Sweden)

    Eom Hee Seung

    2016-01-01

    Full Text Available Cinnamyl alcohol dehydrogenase (CAD is a key enzyme in the biosynthesis of lignin and lignans as it catalyzes the final step of monolignol biosynthesis, using NADPH as a cofactor. In higher plants, CAD is encoded by a multigene family consisting of three major classes. Based on the recently released flax (Linum usitatissimum L. whole-genome sequences, in this study we identified six CAD family genes that contain an ADH_N domain and an ADH_zinc_N domain, which suggests that the putative flax CADs (LuCADs are zinc-dependent alcohol dehydrogenases and members of the plant CAD family. In addition, expression analysis using quantitative real-time PCR revealed spatial variations in the expression of LuCADs in different organs. Comparative analysis between LuCAD enzymatic activity and LuCAD transcripts indicates that the variation of LuCAD enzymatic activities by elicitors is reflected by transcription of LuCADs in flax suspension-cultured cells. Taken together, our genome-wide analysis of CAD genes and the expression profiling of these genes provide valuable information for understanding the function of CADs, and will assist future studies on the physiological role of monolignols associated with plant defense.

  13. Distortion of CAD-CAM-fabricated implant-fixed titanium and zirconia complete dental prosthesis frameworks.

    Science.gov (United States)

    Al-Meraikhi, Hadi; Yilmaz, Burak; McGlumphy, Edwin; Brantley, William A; Johnston, William M

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD-CAM)-fabricated titanium and zirconia implant-supported fixed dental prostheses have become increasingly popular for restoring patients with complete edentulism. However, the distortion level of these frameworks is not well known. The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of CAD-CAM zirconia and titanium implant-fixed screw-retained complete dental prostheses. A master edentulous model with 4 implants at the positions of the maxillary first molars and canines was used. Multiunit abutments (Nobel Biocare) secured to the model were digitally scanned using scan bodies and a laboratory scanner (S600 ARTI; Zirkonzahn). Titanium (n=5) and zirconia (n=5) frameworks were milled using a CAD-CAM system (Zirkonzahn M1; Zirkonzahn). All frameworks were scanned using an industrial computed tomography (CT) scanner (Nikon/X-Tek XT H 225kV MCT Micro-Focus). The direct CT scans were reconstructed to generate standard tessellation language (STL) files. To calculate the 3D distortion of the frameworks, STL files of the CT scans were aligned to the CAD model using a sum of the least squares best-fit algorithm. Surface comparison points were placed on the CAD model on the midfacial aspect of all teeth. The 3D distortion of each direct scan to the CAD model was calculated. In addition, color maps of the scan-to-CAD comparison were constructed using a ±0.500 mm color scale range. Both materials exhibited distortion; however, no significant difference was found in the amount of distortion from the CAD model between the materials (P=.747). Absolute values of deviations from the CAD model were evident in the x and y plane and less so in the z direction. Zirconia and titanium frameworks showed similar 3D distortion compared with the CAD model for the tested CAD-CAM and implant systems. The distortion was more pronounced in the horizontal and sagittal plane than in the vertical plane

  14. True Concurrent Thermal Engineering Integrating CAD Model Building with Finite Element and Finite Difference Methods

    Science.gov (United States)

    Panczak, Tim; Ring, Steve; Welch, Mark

    1999-01-01

    Thermal engineering has long been left out of the concurrent engineering environment dominated by CAD (computer aided design) and FEM (finite element method) software. Current tools attempt to force the thermal design process into an environment primarily created to support structural analysis, which results in inappropriate thermal models. As a result, many thermal engineers either build models "by hand" or use geometric user interfaces that are separate from and have little useful connection, if any, to CAD and FEM systems. This paper describes the development of a new thermal design environment called the Thermal Desktop. This system, while fully integrated into a neutral, low cost CAD system, and which utilizes both FEM and FD methods, does not compromise the needs of the thermal engineer. Rather, the features needed for concurrent thermal analysis are specifically addressed by combining traditional parametric surface based radiation and FD based conduction modeling with CAD and FEM methods. The use of flexible and familiar temperature solvers such as SINDA/FLUINT (Systems Improved Numerical Differencing Analyzer/Fluid Integrator) is retained.

  15. Fabricating Complete Dentures with CAD/CAM and RP Technologies.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Aglarci, Osman Sami; Dilber, Erhan

    2015-06-01

    Two techological approaches for fabricating dentures; computer-aided design and computer-aided manufacturing (CAD/CAM) and rapid prototyping (RP), are combined with the conventional techniques of impression and jaw relation recording to determine their feasibility and applicability. Maxillary and mandibular edentulous jaw models were produced using silicone molds. After obtaining a gypsum working model, acrylic bases were crafted, and occlusal rims for each model were fabricated with previously determined standard vertical and centric relationships. The maxillary and mandibular relationships were recorded with guides. The occlusal rims were then scanned with a digital scanner. The alignment of the maxillary and mandibular teeth was verified. The teeth in each arch were fabricated in one piece, or set, either by CAM or RP. Conventional waxing and flasking was then performed for both methods. These techniques obviate a practitioner's need for technicians during design and provide the patient with an opportunity to participate in esthetic design with the dentist. In addition, CAD/CAM and RP reduce chair time; however, the materials and techniques need further improvements. Both CAD/CAM and RP techniques seem promising for reducing chair time and allowing the patient to participate in esthetics design. Furthermore, the one-set aligned artificial tooth design may increase the acrylic's durability. © 2015 by the American College of Prosthodontists.

  16. VLSI Design with Alliance Free CAD Tools: an Implementation Example

    Directory of Open Access Journals (Sweden)

    Chávez-Bracamontes Ramón

    2015-07-01

    Full Text Available This paper presents the methodology used for a digital integrated circuit design that implements the communication protocol known as Serial Peripheral Interface, using the Alliance CAD System. The aim of this paper is to show how the work of VLSI design can be done by graduate and undergraduate students with minimal resources and experience. The physical design was sent to be fabricated using the CMOS AMI C5 process that features 0.5 micrometer in transistor size, sponsored by the MOSIS Educational Program. Tests were made on a platform that transfers data from inertial sensor measurements to the designed SPI chip, which in turn sends the data back on a parallel bus to a common microcontroller. The results show the efficiency of the employed methodology in VLSI design, as well as the feasibility of ICs manufacturing from school projects that have insufficient or no source of funding

  17. Peningkatan Prestasi Belajar CAD Mahasiswa Teknik Otomotif Non-Reguler FT UNY melalui Pembuatan “Pohon Kata” Perintah dalam Program AutoCAD

    Directory of Open Access Journals (Sweden)

    Martubi Martubi

    2010-05-01

    Full Text Available Penelitian ini bertujuan meningkatkan prestasi belajar mata kuliah Computer Aided Design (CAD mahasiswa prodi Teknik Otomotif Non-Reguler yang dinyatakan dalam bentuk rerata nilai akhir semester yang berasal dari komponen nilai tugas harian, nilai ujian tengah semester dan nilai ujian akhir semester. Penelitian quasi-eksperimen ini terdiri dari tahapan penelitian diawali dengan penyusunan materi pembelajaran sejumlah pokok bahasan tertentu dalam satu job sheet (lembar kerja, dilanjutkan dengan pembuatan bantuan “Pohon Kata” perintah dalam Auto CAD kepada kelas eksperimen yang ditentukan secara random dari dua kelas peserta kuliah Auto CAD pada Semester Genap 2008/2009. Kedua kelas diamati prestasinya, baik kecepatan penyelesaiannya maupun kualitas kebenaran gambarnya. Prestasi belajar kedua kelas juga diukur melalui pemberian ujian tengah semester dan ujian akhir semester. Setelah data prestasi kedua kelas terkumpul dilanjutkan dengan analisis statistik melalui uji beda (t-test setelah sebelumnya dilakukan uji persyaratan analisis yang ternyata dapat dipenuhi. Hasil penelitian ini disimpulkan bahwa: prestasi belajar CAD mahasiswa pada kelas yang diberi perlakuan strategi pembelajaran menggunakan “Pohon Kata” perintah dalam Program Auto CAD lebih baik dibanding prestasi belajar CAD mahasiswa pada kelas yang tidak diberi perlakuan (75,41>70,89, dengan demikian pembelajaran CAD menggunakan media “Pohon Kata” perintah dalam Program Auto CAD dapat meningkatkan prestasi belajar mahasiswa Teknik Otomotif Program Non-Reguler.

  18. Combining photogrammetry and CAD

    International Nuclear Information System (INIS)

    Borowsky, V.

    1993-01-01

    In nuclear power plants photogrammetry is being used to supply the data needed for setting up 3D CAD models. At Siemens, project handling has been made more economical by using photogrammetry and 3D CAD as a single process. Photogrammetry can be used for modelling extensive sections of the plant or small areas. Areas which particularly lend themselves to the use of photogrammetry are those with a high level of radiation or those yielding a large volume of data. (author)

  19. Successfully converting mine maps to CAD

    Energy Technology Data Exchange (ETDEWEB)

    Munn, M.D. (Image Conversion Services, Inc., Salt Lake City, UT (USA))

    1991-03-01

    Procedures followed by computer service bureaus to convert paper drawing to digital files that can be used by CAD systems are described. The conversion involves laser scanning of original drawings to produce an 'inactive image' (a form suitable for many drawings that do not need to be changed). Using optical character recognition software the image is then vectorized or converted from raster format to geometric elements usable in a CAD system. The vectorized image can then be cleaned up corrected and changed at the CAD workstation. 4 figs.

  20. Manipulating cinnamyl alcohol dehydrogenase (CAD) expression in flax affects fibre composition and properties

    Science.gov (United States)

    2014-01-01

    Background In recent decades cultivation of flax and its application have dramatically decreased. One of the reasons for this is unpredictable quality and properties of flax fibre, because they depend on environmental factors, retting duration and growing conditions. These factors have contribution to the fibre composition, which consists of cellulose, hemicelluloses, lignin and pectin. By far, it is largely established that in flax, lignin reduces an accessibility of enzymes either to pectin, hemicelluloses or cellulose (during retting or in biofuel synthesis and paper production). Therefore, in this study we evaluated composition and properties of flax fibre from plants with silenced CAD (cinnamyl alcohol dehydrogenase) gene, which is key in the lignin biosynthesis. There is evidence that CAD is a useful tool to improve lignin digestibility and/or to lower the lignin levels in plants. Results Two studied lines responded differentially to the introduced modification due to the efficiency of the CAD silencing. Phylogenetic analysis revealed that flax CAD belongs to the “bona-fide” CAD family. CAD down-regulation had an effect in the reduced lignin amount in the flax fibre cell wall and as FT-IR results suggests, disturbed lignin composition and structure. Moreover introduced modification activated a compensatory mechanism which was manifested in the accumulation of cellulose and/or pectin. These changes had putative correlation with observed improved fiber’s tensile strength. Moreover, CAD down-regulation did not disturb at all or has only slight effect on flax plants’ development in vivo, however, the resistance against flax major pathogen Fusarium oxysporum decreased slightly. The modification positively affected fibre possessing; it resulted in more uniform retting. Conclusion The major finding of our paper is that the modification targeted directly to block lignin synthesis caused not only reduced lignin level in fibre, but also affected amount and

  1. Theory and practice of Auto CAD, computer graphics

    International Nuclear Information System (INIS)

    Hwang, Si Won; Choe, Hong Yeong; Shin, Jae Yeon; Lee, Ryong Cheol

    1990-08-01

    This book describes theory and practice of Auto CAD, computer graphics, which deals with peripheral of computer, occurrence of digital line by DDA, BRM, theory of conversion, data base and display and shape modeling. This book gives descriptions of outline of CAD system, Auto CAD, basic function practice, simple figure practice, the third angle projection drawing a little complex single object, machine drawing I, function practice of improved Auto CAD, edit, set up layer, and 3D, and 3D display function.

  2. Immersive CAD

    Energy Technology Data Exchange (ETDEWEB)

    Ames, A.L.

    1999-02-01

    This paper documents development of a capability for performing shape-changing editing operations on solid model representations in an immersive environment. The capability includes part- and assembly-level operations, with part modeling supporting topology-invariant and topology-changing modifications. A discussion of various design considerations in developing an immersive capability is included, along with discussion of a prototype implementation we have developed and explored. The project investigated approaches to providing both topology-invariant and topology-changing editing. A prototype environment was developed to test the approaches and determine the usefulness of immersive editing. The prototype showed exciting potential in redefining the CAD interface. It is fun to use. Editing is much faster and friendlier than traditional feature-based CAD software. The prototype algorithms did not reliably provide a sufficient frame rate for complex geometries, but has provided the necessary roadmap for development of a production capability.

  3. Dataudveksling mellem CAD og CAE programmer

    DEFF Research Database (Denmark)

    Sørensen, Torben; Conrad, Finn

    2001-01-01

    Når mange forskelligartede programmer benyttes til beregninger og anden databehandling på samme modeller er det nødvendig at udveksle modellerne mellem disse forskellige programmer. Biler og skibe bliver f.eks. typisk designet i 3D CAD systemer, mens CAD modellerne herefter anvendes i andre...... dedikerede IT-systemer i forbindelse montageplanlægningen, svejseplanlægningen, robotprogrammeringen mm. der således her et behov for at udveksle CAD modellen mellem de forskellige programmer. Udveksling af information mellem forskellige programmer og systemer kræver såvel en fælles specifikation af det...

  4. Refining a brief decision aid in stable CAD: cognitive interviews.

    Science.gov (United States)

    Kelly-Blake, Karen; Clark, Stacie; Dontje, Katherine; Olomu, Adesuwa; Henry, Rebecca C; Rovner, David R; Rothert, Marilyn L; Holmes-Rovner, Margaret

    2014-02-13

    We describe the results of cognitive interviews to refine the "Making Choices©" Decision Aid (DA) for shared decision-making (SDM) about stress testing in patients with stable coronary artery disease (CAD). We conducted a systematic development process to design a DA consistent with International Patient Decision Aid Standards (IPDAS) focused on Alpha testing criteria. Cognitive interviews were conducted with ten stable CAD patients using the "think aloud" interview technique to assess the clarity, usefulness, and design of each page of the DA. Participants identified three main messages: 1) patients have multiple options based on stress tests and they should be discussed with a physician, 2) take care of yourself, 3) the stress test is the gold standard for determining the severity of your heart disease. Revisions corrected the inaccurate assumption of item number three. Cognitive interviews proved critical for engaging patients in the development process and highlighted the necessity of clear message development and use of design principles that make decision materials easy to read and easy to use. Cognitive interviews appear to contribute critical information from the patient perspective to the overall systematic development process for designing decision aids.

  5. Design, preparation and preliminary use of a novel biomimetic agent rFN/CAD

    Directory of Open Access Journals (Sweden)

    Hong KUANG

    2012-12-01

    Full Text Available Objective  To prepare a novel biomimetic agent with adhesive and osteoinduction capabilities, and provide a new approach for improving seeding cell adhesion and osteoblastic differentiation on a scaffold surface. Methods  A novel bifunctional recombinant protein was engineered and prepared by bioinformatics, standard molecular cloning, protein expression and purification techniques. A centrifugal cell adhesive assay and an osteoinduction assay were employed to determine the biofunction ex vivo. Results  A 1954bp long DNA chimera of FN Ⅲ7-10/CAD11 EC1-2 and recombinant FN Ⅲ7-10/CAD11 EC1-2 of 641 amino acids were obtained. Polystyrene surface coated with this protein significantly increased the adhesive property and osteodifferentiation of human bone marrow mesenchymal stem cells. Conclusion  rFN/CAD possesses dual biofunctions of osteoblastic adhesion and differentiation, which can be further applied as an ideal biomimetic molecule for surface modification.

  6. Use of Existing CAD Models for Radiation Shielding Analysis

    Science.gov (United States)

    Lee, K. T.; Barzilla, J. E.; Wilson, P.; Davis, A.; Zachman, J.

    2015-01-01

    The utility of a radiation exposure analysis depends not only on the accuracy of the underlying particle transport code, but also on the accuracy of the geometric representations of both the vehicle used as radiation shielding mass and the phantom representation of the human form. The current NASA/Space Radiation Analysis Group (SRAG) process to determine crew radiation exposure in a vehicle design incorporates both output from an analytic High Z and Energy Particle Transport (HZETRN) code and the properties (i.e., material thicknesses) of a previously processed drawing. This geometry pre-process can be time-consuming, and the results are less accurate than those determined using a Monte Carlo-based particle transport code. The current work aims to improve this process. Although several Monte Carlo programs (FLUKA, Geant4) are readily available, most use an internal geometry engine. The lack of an interface with the standard CAD formats used by the vehicle designers limits the ability of the user to communicate complex geometries. Translation of native CAD drawings into a format readable by these transport programs is time consuming and prone to error. The Direct Accelerated Geometry -United (DAGU) project is intended to provide an interface between the native vehicle or phantom CAD geometry and multiple particle transport codes to minimize problem setup, computing time and analysis error.

  7. AutoCAD 2014 review for certification official certification preparation

    CERN Document Server

    ASCENT center for technical knowledge

    2014-01-01

    The AutoCAD® 2014 Review for Certification book is intended for users of AutoCAD® preparing to complete the AutoCAD 2014 Certified Professional exam. This book contains a collection of relevant instructional topics, practice exercises, and review questions from the Autodesk Official Training Guides (AOTG) from ASCENT - Center for Technical Knowledge pertaining specifically to the Certified Professional exam topics and objectives. This book is intended for experienced users of AutoCAD in preparation for certification. New users of AutoCAD should refer to the AOTG training guides from ASCENT, such as AutoCAD/AutoCAD LT 2014 Fundamentals, for more comprehensive instruction.

  8. DEVELOPMENT OF EDIFICATION’S PROJECT – A COMPARATIVE STUDY ODF CAD AND BIM PLATAFORMS

    Directory of Open Access Journals (Sweden)

    Lúcio Campos Neto

    2017-12-01

    Full Text Available Several technologies are used to simplify the process and creation of design, highlighting the CAD and the BIM. At CAD, the elements are represented by lines, while at BIM the objects are ruled by attributes and parametric information, allowing the virtual simulation of the edification. Although the BIM is a novelty in design’s process, the largest part of professionals still makes use of CAD. In front of these facts, the objective of this research is to evaluate the difference of using each plataform. The research was guided by the hypothesis that BIM concept presents pros and cons to the process of projects development once it is compared to CAD software. For this, one same project has been developed in both plataforms in order to demonstrate which plataform has the best characteristics at the development process and final result, indicating its difficulties, facilies, esthetics, reading, handling, interface and tools. With the proposed methodology execution, it has been noticed that each plataform possesses positive and negative characteristics, influencing each professional’s choice for a software. This choice will vary according to the situation, to what plataform the professional gets better used to and according to the investment potential.

  9. Role of radiologists in CAD life-cycle

    Energy Technology Data Exchange (ETDEWEB)

    Pietka, Ewa, E-mail: ewa.pietka@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Kawa, Jacek, E-mail: jacek.kawa@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Spinczyk, Dominik, E-mail: dominik.spinczyk@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Badura, Pawel, E-mail: pawel.badura@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Wieclawek, Wojciech, E-mail: wojciech.wieclawek@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Czajkowska, Joanna, E-mail: joanna.czajkowska@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Rudzki, Marcin, E-mail: marcin.rudzki@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland)

    2011-05-15

    A modern CAD (computer-aided diagnosis) system development involves a multidisciplinary team whose members are experts in medical and technical fields. This study indicates the activities of medical experts at various stages of the CAD design, testing, and implementation. Those stages include a medical analysis of the diagnostic problem, data collection, image analysis, evaluation, and clinical verification. At each stage the physicians knowledge and experience are indispensable. The final implementation involves integration with the existing Picture Archiving and Communication System. The term CAD life-cycle describes an overall process of the design, testing, and implementation of a system that in its final form assists the radiologists in their daily clinical routine. Four CAD systems (applied to the bone age assessment, Multiple Sclerosis detection, lung nodule detection, and pneumothorax measurement) developed in our laboratory are given as examples of how consecutive stages are developed by the multidisciplinary team. Specific advantages of the CAD implementation that include the daily clinical routine as well as research and education activities are discussed.

  10. Role of radiologists in CAD life-cycle

    International Nuclear Information System (INIS)

    Pietka, Ewa; Kawa, Jacek; Spinczyk, Dominik; Badura, Pawel; Wieclawek, Wojciech; Czajkowska, Joanna; Rudzki, Marcin

    2011-01-01

    A modern CAD (computer-aided diagnosis) system development involves a multidisciplinary team whose members are experts in medical and technical fields. This study indicates the activities of medical experts at various stages of the CAD design, testing, and implementation. Those stages include a medical analysis of the diagnostic problem, data collection, image analysis, evaluation, and clinical verification. At each stage the physicians knowledge and experience are indispensable. The final implementation involves integration with the existing Picture Archiving and Communication System. The term CAD life-cycle describes an overall process of the design, testing, and implementation of a system that in its final form assists the radiologists in their daily clinical routine. Four CAD systems (applied to the bone age assessment, Multiple Sclerosis detection, lung nodule detection, and pneumothorax measurement) developed in our laboratory are given as examples of how consecutive stages are developed by the multidisciplinary team. Specific advantages of the CAD implementation that include the daily clinical routine as well as research and education activities are discussed.

  11. Importing CAD models into MONK and MCBEND

    International Nuclear Information System (INIS)

    Searson, K.; Fleurot, F.; Cooper, A. J.; Cowan, P.

    2009-01-01

    The direct use of Computer Aided Design (CAD) models in criticality and shielding codes has been a long standing goal for Sellafield Ltd. Such functionality could offer several advantages over the traditional method of text based modelling systems. Analysts would be able to take advantage of the advanced Graphical User Interface based modelling features provided by solid modelers, potentially reducing the costs associated with creating models in a format suitable for the analyst's criticality and shielding code. A prototype system has been developed that allows CAD models created in Autodesk Inventor or Solidworks to be used in criticality and shielding calculations. The system is based on the ANSI Initial Graphics Exchange Specification 5.3 standard and models are exported from the CAD software in Trimmed NURBS format. The format retains much more of the model's geometrical information than a format based on solid meshing techniques and avoids many of the associated problems such as large memory costs, surface approximations and void spaces. The time consuming and complex meshing process is also avoided. Runtime intersection calculations are performed using either a Bezier clipping process for NURBS based surface definitions, or by transforming the coordinate system through which the ray tracks for Surface of Revolution calculations. NURBS surfaces are therefore converted to Bezier form as the model is imported. In addition, the SR generatrix is, in general, converted to a 'strip tree' representation, allowing the SR intersection calculations to be performed with arbitrary generatrix shapes. Details of recent improvements to the Bezier clipping process are provided. Reduction in runtime of SR based Solidworks models over equivalent NURBS based Autodesk Inventor models is also demonstrated. (authors)

  12. Engineering applications using CAD based application programming interface

    Directory of Open Access Journals (Sweden)

    Tzotzis Anastasios

    2017-01-01

    Full Text Available Automating the design process of a product or a system can provide engineers and designers with many benefits. As such, repeatable tasks that are time consuming can be handled automatically and with minimal human attention. This is achieved by using the API (Application Programmable Interface of CAD systems in order to create macros or even develop software applications. The present paper deals with an application that has been developed with the API of a general purposes CAD system. This application automates the design process of a standard pneumatic double acting cylinder based on the appropriate inserted parameters (ISO 15552.The design process begins with the creation of a series of components developed as solids, and extends to the extraction of basic attributes and properties from the complete mechanical assembly. Finally, the assembled models and the extracted data can be used to further study the design of the pneumatic double acting cylinder. It is expected in the future to expand the features of the presented application in order to automate the design process of other related mechanical systems.

  13. CAD/CAM produces dentures with improved fit.

    Science.gov (United States)

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  14. Bonding Effectiveness of Luting Composites to Different CAD/CAM Materials.

    Science.gov (United States)

    Peumans, Marleen; Valjakova, Emilija Bajraktarova; De Munck, Jan; Mishevska, Cece Bajraktarova; Van Meerbeek, Bart

    To evaluate the influence of different surface treatments of six novel CAD/CAM materials on the bonding effectiveness of two luting composites. Six different CAD/CAM materials were tested: four ceramics - Vita Mark II; IPS Empress CAD and IPS e.max CAD; Celtra Duo - one hybrid ceramic, Vita Enamic, and one composite CAD/CAM block, Lava Ultimate. A total of 60 blocks (10 per material) received various mechanical surface treatments: 1. 600-grit SiC paper; 2. sandblasting with 30-μm Al2O3; 3. tribochemical silica coating (CoJet). Subsequent chemical surface treatments involved either no further treatment (control), HF acid etching (HF), silanization (S, or HF acid etching followed by silanization (HF+S). Two specimens with the same surface treatment were bonded together using two dual-curing luting composites: Clearfil Esthetic Cement (self-etching) or Panavia SA Cement (self-adhesive). After 1 week of water storage, the microtensile bond strength of the sectioned microspecimens was measured and the failure mode was evaluated. The bonding performance of the six CAD/CAM materials was significantly influenced by surface treatment (linear mixed models, p CAD (p = 0.0115), and Lava Ultimate (p CAD/CAM materials: Vita Mark II and IPS Empress CAD: S, HF+S; Celtra Duo: HF, HF+S; IPS e.max CAD: HF+S; Vita Enamic: HF+S, S. For Lava Ultimate, the highest bond strengths were obtained with HF, S, HF+S. Failure analysis showed a relation between bond strength and failure type: more mixed failures were observed with higher bond strengths. Mainly adhesive failures were noticed if no further surface treatment was done. The percentage of adhesive failures was higher for CAD/CAM materials with higher flexural strength (Celtra Duo, IPS e.max CAD, and Lava Ultimate). The bond strength of luting composites to novel CAD/CAM materials is influenced by surface treatment. For each luting composite, an adhesive cementation protocol can be specified in order to obtain the highest bond to the

  15. Standard Analyzer of VHDL Applications for Next Generation Technology (SAVANT)

    National Research Council Canada - National Science Library

    Hirsch, Herbert

    1995-01-01

    ... (IF) for the exchange of VHDL encoded electronic data among CAD systems. This absence has severely constrained basic research environments, and has precipitated the current sub-optimal nature of CAD in VHDL tool development...

  16. Role of Computer Aided Diagnosis (CAD in the detection of pulmonary nodules on 64 row multi detector computed tomography

    Directory of Open Access Journals (Sweden)

    K Prakashini

    2016-01-01

    Full Text Available Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2% and 202 (91.4% by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4% and nodules in hilar (100% and central (96.5% location when compared to RAD′s performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD′s performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  17. Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography.

    Science.gov (United States)

    Prakashini, K; Babu, Satish; Rajgopal, K V; Kokila, K Raja

    2016-01-01

    To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  18. CAD: How it works, how to use it, performance

    International Nuclear Information System (INIS)

    Regge, Daniele; Halligan, Steve

    2013-01-01

    Computer-aided diagnosis (CAD) systems are software algorithms designed to assist radiologists (or other practitioners) in solving a diagnostic problem by using a visual prompt (or “CAD mark”) to direct the observer towards potential pathology. CT colonography is a recent arrival to CAD, but could represent one of its most fruitful applications in the future. In contrast to other organs, where a variety of different pathologies are equally represented, significant colorectal pathologies other than polyps and cancer are relatively uncommon. As we shall see, this simplifies the diagnostic task for artificial intelligence developers and also for radiologists who, ultimately, must make the final decision. This review aims to present the current state-of-the-art for CAD applied to CT colonography. A brief overview of the technical essentials and of the diagnostic performance of CAD in isolation, is followed by an explanation of how CAD is used in day-to-day practice. The last section will deal with the most controversial issues affecting CAD performance in clinical practice, with a focus on the interaction between human and artificial intelligence

  19. CAD: How it works, how to use it, performance

    Energy Technology Data Exchange (ETDEWEB)

    Regge, Daniele, E-mail: daniele.regge@ircc.it [Institute for Cancer Research and Treatment, Candiolo-Torino (Italy); Halligan, Steve, E-mail: s.halligan@ucl.ac.uk [University College Hospital London, London (United Kingdom)

    2013-08-15

    Computer-aided diagnosis (CAD) systems are software algorithms designed to assist radiologists (or other practitioners) in solving a diagnostic problem by using a visual prompt (or “CAD mark”) to direct the observer towards potential pathology. CT colonography is a recent arrival to CAD, but could represent one of its most fruitful applications in the future. In contrast to other organs, where a variety of different pathologies are equally represented, significant colorectal pathologies other than polyps and cancer are relatively uncommon. As we shall see, this simplifies the diagnostic task for artificial intelligence developers and also for radiologists who, ultimately, must make the final decision. This review aims to present the current state-of-the-art for CAD applied to CT colonography. A brief overview of the technical essentials and of the diagnostic performance of CAD in isolation, is followed by an explanation of how CAD is used in day-to-day practice. The last section will deal with the most controversial issues affecting CAD performance in clinical practice, with a focus on the interaction between human and artificial intelligence.

  20. The Role of Flow Experience and CAD Tools in Facilitating Creative Behaviours for Architecture Design Students

    Science.gov (United States)

    Dawoud, Husameddin M.; Al-Samarraie, Hosam; Zaqout, Fahed

    2015-01-01

    This study examined the role of flow experience in intellectual activity with an emphasis on the relationship between flow experience and creative behaviour in design using CAD. The study used confluence and psychometric approaches because of their unique abilities to depict a clear image of creative behaviour. A cross-sectional study…

  1. Annotation and retrieval system of CAD models based on functional semantics

    Science.gov (United States)

    Wang, Zhansong; Tian, Ling; Duan, Wenrui

    2014-11-01

    CAD model retrieval based on functional semantics is more significant than content-based 3D model retrieval during the mechanical conceptual design phase. However, relevant research is still not fully discussed. Therefore, a functional semantic-based CAD model annotation and retrieval method is proposed to support mechanical conceptual design and design reuse, inspire designer creativity through existing CAD models, shorten design cycle, and reduce costs. Firstly, the CAD model functional semantic ontology is constructed to formally represent the functional semantics of CAD models and describe the mechanical conceptual design space comprehensively and consistently. Secondly, an approach to represent CAD models as attributed adjacency graphs(AAG) is proposed. In this method, the geometry and topology data are extracted from STEP models. On the basis of AAG, the functional semantics of CAD models are annotated semi-automatically by matching CAD models that contain the partial features of which functional semantics have been annotated manually, thereby constructing CAD Model Repository that supports model retrieval based on functional semantics. Thirdly, a CAD model retrieval algorithm that supports multi-function extended retrieval is proposed to explore more potential creative design knowledge in the semantic level. Finally, a prototype system, called Functional Semantic-based CAD Model Annotation and Retrieval System(FSMARS), is implemented. A case demonstrates that FSMARS can successfully botain multiple potential CAD models that conform to the desired function. The proposed research addresses actual needs and presents a new way to acquire CAD models in the mechanical conceptual design phase.

  2. Assessment of reliability of CAD-CAM tooth-colored implant custom abutments.

    Science.gov (United States)

    Guilherme, Nuno Marques; Chung, Kwok-Hung; Flinn, Brian D; Zheng, Cheng; Raigrodski, Ariel J

    2016-08-01

    Information is lacking about the fatigue resistance of computer-aided design and computer-aided manufacturing (CAD-CAM) tooth-colored implant custom abutment materials. The purpose of this in vitro study was to investigate the reliability of different types of CAD-CAM tooth-colored implant custom abutments. Zirconia (Lava Plus), lithium disilicate (IPS e.max CAD), and resin-based composite (Lava Ultimate) abutments were fabricated using CAD-CAM technology and bonded to machined titanium-6 aluminum-4 vanadium (Ti-6Al-4V) alloy inserts for conical connection implants (NobelReplace Conical Connection RP 4.3×10 mm; Nobel Biocare). Three groups (n=19) were assessed: group ZR, CAD-CAM zirconia/Ti-6Al-4V bonded abutments; group RC, CAD-CAM resin-based composite/Ti-6Al-4V bonded abutments; and group LD, CAD-CAM lithium disilicate/Ti-6Al-4V bonded abutments. Fifty-seven implant abutments were secured to implants and embedded in autopolymerizing acrylic resin according to ISO standard 14801. Static failure load (n=5) and fatigue failure load (n=14) were tested. Weibull cumulative damage analysis was used to calculate step-stress reliability at 150-N and 200-N loads with 2-sided 90% confidence limits. Representative fractured specimens were examined using stereomicroscopy and scanning electron microscopy to observe fracture patterns. Weibull plots revealed β values of 2.59 for group ZR, 0.30 for group RC, and 0.58 for group LD, indicating a wear-out or cumulative fatigue pattern for group ZR and load as the failure accelerating factor for groups RC and LD. Fractographic observation disclosed that failures initiated in the interproximal area where the lingual tensile stresses meet the compressive facial stresses for the early failure specimens. Plastic deformation of titanium inserts with fracture was observed for zirconia abutments in fatigue resistance testing. Significantly higher reliability was found in group ZR, and no significant differences in reliability were

  3. Improving the radiologist-CAD interaction : designing for appropriate trust

    NARCIS (Netherlands)

    Jorritsma, W.; Cnossen, F.; van Ooijen, P. M. A.

    Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist-CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the

  4. 3D CAD model of the subcritical nuclear reactor of IPN; Modelo CAD 3D del reactor nuclear subcritico del IPN

    Energy Technology Data Exchange (ETDEWEB)

    Pahuamba V, F. de J.; Delfin L, A.; Gomez T, A. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Ibarra R, G.; Del Valle G, E.; Sanchez R, A., E-mail: narehc@hotmail.com [IPN, Escuela Superior de Fisica y Matematicas, Av. IPN, Edif. 9, Unidad Profesional Adolfo Lopez Mateos, San Pedro Zacatenco, 07738 Ciudad de Mexico (Mexico)

    2016-09-15

    The three-dimensional (3D) CAD model of the subcritical reactor Chicago model 9000 of Instituto Politecnico Nacional (IPN) allows obtaining a 3D view with the dimensions of each of its components, such as: natural uranium cylindrical rods, fuel elements, hexagonal reactor core arrangement, cylindrical stainless steel tank containing the core, fuel element support grids and reactor water cleaning system. As a starting point for the development of the model, the Chicago model 9000 subcritical reactor manual provided by the manufacturer was used, the measurement and verification of the components to adapt the geometric, physical and mechanical characteristics was carried out and materials standards were used to obtain a design that allows to elaborate a new manual according to the specifications. In addition, the 3D models of the building of the Advanced Physics Laboratory, neutron generator, cobalt source and the corridors connecting to the subcritical reactor facility were developed, allowing an animated ride, developed by computer-aided design software. The manual provided by the company Nuclear Chicago, dates from the year 1959 and presents diverse deviations in the design and dimensions of the reactor components. The model developed; in addition to supporting the development of the new manual represents a learning tool to visualize the reactor components. (Author)

  5. Software planning and analysis for automated design system AutoCAD

    OpenAIRE

    Koskutė, Lina

    2007-01-01

    AutoCAD sistemos papildymas sukurtas tam, kad būtų lengviau ir paprasčiau dirbti su AutoCAD grafine sistema. Funkcijos sukurtos naudojant AutoLisp ir VisualLISP programavimo kalbas. Sistemos papildymą galima įdiegti į bet kurią AutoCAD versiją. Sukurtas papildymas lankstus naujų funkcijų prijungimui, lengvai eksploatuojamas. Funkcijos suskirstytos į keletą grupių pagal jų formatą. AutoCAD system complement is created to make more easy working with AutoCAD graphic system. Functions are crea...

  6. Are unnecessary follow-up procedures induced by computer-aided diagnosis (CAD) in mammography? Comparison of mammographic diagnosis with and without use of CAD

    International Nuclear Information System (INIS)

    Marx, Christiane; Malich, Ansgar; Facius, Mirjam; Grebenstein, Uta; Sauner, Dieter; Pfleiderer, Stefan O.R.; Kaiser, Werner A.

    2004-01-01

    Objective: To evaluate the rate of unnecessary follow-up procedures recommended by radiologists using a CAD-system. Materials and methods: 185 patients (740 images) were consecutively selected from three groups (36 histologically proven cancers=group 1; 49 histologically proven benign lesions=group 2 and 100 screening cases (4 years-follow up=group 3). Mammograms were evaluated by a CAD system (Second Look [reg] , CADx, Canada). Five blinded radiologists assessed the images without/with CAD outputs. Diagnostic decisions were ranked from surely benign to surely malignant according to BIRADS classification, follow-up procedures were recommended for each observed lesion (a, screening; b, short interval follow-up examination in 6 months; c, pathologic clarification). Results: CAD-system detected 32/36 cancers (88.9%) (FP-rate: 1.04 massmarks and 0.27 calcmarks/image). The following values were reached by all observers without/with CAD in the mean: Sensitivity 80.6/80.0%, specificity 83.2/86.4%, PPV 53.1/58.1%, and NPV 94.6/94.7%. Observers described a similar number of additional lesions without/with the use of CAD (325/326). Whereas the number of unnecessary short-time follow up recommendations increased in all case-subgroups with CAD: 40.8/42.9% (group 1), 35.6/38.1% (group 2), 44.7/46.8% (group 3), respectively, the number of recommended biopsies decreased in all subgroups: group 1: 34.7/27.1%; group 2: 47.4/41.5%, group 3: 33.3/22.0%, respectively. Conclusion: In this rather small population additional usage of CAD led to a lower rate of unnecessary biopsies. The observed decrease of recommended unnecessary biopsies due to the usage of CAD in the screening group suggests a potential financial benefit by using CAD as diagnostic aid

  7. GenoCAD Plant Grammar to Design Plant Expression Vectors for Promoter Analysis.

    Science.gov (United States)

    Coll, Anna; Wilson, Mandy L; Gruden, Kristina; Peccoud, Jean

    2016-01-01

    With the rapid advances in prediction tools for discovery of new promoters and their cis-elements, there is a need to improve plant expression methodologies in order to facilitate a high-throughput functional validation of these promoters in planta. The promoter-reporter analysis is an indispensible approach for characterization of plant promoters. It requires the design of complex plant expression vectors, which can be challenging. Here, we describe the use of a plant grammar implemented in GenoCAD that will allow the users to quickly design constructs for promoter analysis experiments but also for other in planta functional studies. The GenoCAD plant grammar includes a library of plant biological parts organized in structural categories to facilitate their use and management and a set of rules that guides the process of assembling these biological parts into large constructs.

  8. CAD/CAM/CNC.

    Science.gov (United States)

    Domermuth, Dave; And Others

    1996-01-01

    Includes "Quick Start CNC (computer numerical control) with a Vacuum Filter and Laminated Plastic" (Domermuth); "School and Industry Cooperate for Mutual Benefit" (Buckler); and "CAD (computer-assisted drafting) Careers--What Professionals Have to Say" (Skinner). (JOW)

  9. THE CONFORMITY OF MACHINE TOOLS WITH RESPECT TO EUROPEAN SAFETY STANDARDS

    CERN Multimedia

    TIS/TE

    2001-01-01

    European regulations require that all motorized machine tools conform to the latest safety standards by the end of the year 2000. CERN must follow these regulations and has already modified most of its machine tools accordingly. However, there is still a small number of machine tools which have not yet been modified as required. These machines should not be used until they are brought up to the required safety standards, failing which the machines should be discarded. One can recognise which machine tools conform with the latest standards by the indication 'CS' on the identification plate of the machine, see foto below. In cases of doubt about the status of a machine tool you should contact K. Altherr/EST or C. Margaroli/TIS for advice.

  10. THE CONFORMITY OF MACHINE TOOLS WITH RESPECT TO EUROPEAN SAFETY STANDARDS

    CERN Multimedia

    TIS/TE

    2000-01-01

    European regulations require that all motorized machine tools conform to the latest safety standards by the end of the year 2000. CERN must follow these regulations and has already modified most of its machine tools accordingly. However, there is still a small number of machine tools which have not yet been modified as required. These machines should not be used until they are brought up to the required safety standards, failing which the machines should be discarded. One can recognise which machine tools conform with the latest standards by the indication 'CS' on the identification plate of the machine, see foto below. In cases of doubt about the status of a machine tool you should contact K. Altherr/EST or C. Margaroli/TIS for advice.

  11. Performance and value of CAD-deficient pine- Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Bailian Li; Houmin Chang; Hasan Jameel

    2007-02-28

    The southern US produces 58% of the nation's timber, much of it grown in intensively managed plantations of genetically improved loblolly pine. One of the fastest-growing loblolly pine selections made by the NCSU-Industry Cooperative Tree Improvement Program, whose progeny are widely planted, is also the only known natural carrier of a rare gene, cadn1. This allele codes for deficiency in an enzyme, cinnamyl alcohol dehydrogenase, which catalyzes the last step in the biosynthesis of lignin precursors. This study is to characterize this candidate gene for marker-assisted selection and deployment in the breeding program. This research will enhance the sustainability of forest production in the South, where land-use pressures will limit the total area available in the future for intensively managed plantations. Furthermore, this research will provide information to establish higher-value plantation forests with more desirable wood/fiber quality traits. A rare mutant allele (cad-n1) of the cad gene in loblolly pine (Pinus taeda L.) causes a deficiency in the production of cinnamyl alcohol dehydrogenase (CAD). The effects of this allele were examined by comparing wood density and growth traits of cad-n1 heterozygous trees with those of wild-type trees in a 10-year-old open-pollinated family trial growing under two levels of fertilization in Scotland County, North Carolina. In all, 200 trees were sampled with 100 trees for each treatment. Wood density measurements were collected from wood cores at breast height using x-ray densitometry. We found that the substitution of cad-n1 for a wild-type allele (Cad) was associated with a significant effect on wood density. The cad-n1 heterozygotes had a significantly higher wood density (+2.6%) compared to wild-type trees. The higher density was apparently due to the higher percentage of latewood in the heterozygotes. The fertilization effect was highly significant for both growth and wood density traits. While no cad genotype

  12. Sharing the learning activity using intelligent CAD

    DEFF Research Database (Denmark)

    Duffy, S. M.; Duffy, Alex

    1996-01-01

    In this paper the need for Intelligent Computer Aided Design (Int.CAD) to jointly support design and learning assistance is introduced. The paper focuses on presenting and exploring the possibility of realizing ''learning'' assistance in Int.CAD by introducing a new concept called Shared Learning...

  13. Monitoring the International Standardization Process Theoretical Choices and Methodological Tools

    Directory of Open Access Journals (Sweden)

    Brigitte Juanals

    2012-08-01

    Full Text Available Many organizations are in charge of global security management. This paper outlines and argues for the construction of a theoretical and methodological framework in order to critically assess the new technopolitics currently being developed in the field of global security and which are materialized in standards. The main purpose is to design both a methodology and specific text mining tools to investigate these standards. These tools will be implemented in a platform designed to provide cartographic representations of standards and to assist the navigation of an end-user through a corpus of standards.

  14. AutoCAD platform customization user interface, AutoLISP, VBA, and beyond

    CERN Document Server

    Ambrosius, Lee

    2015-01-01

    Take control of AutoCAD to boost the speed, quality, and precision of your work Senior drafters and savvy users are increasingly taking AutoCAD customization out of the hands of system administrators, and taking control of their own workflow. In AutoCAD Platform Customization, Autodesk customization guru Lee Ambrosius walks you through a multitude of customization options using detailed tutorials and real-world examples applicable to AutoCAD, AutoCAD LT, Civil 3D, Plant 3D, and other programs built on the AutoCAD platform. By unleashing the full power of the software, you'll simplify and str

  15. AutoCAD-To-NASTRAN Translator Program

    Science.gov (United States)

    Jones, A.

    1989-01-01

    Program facilitates creation of finite-element mathematical models from geometric entities. AutoCAD to NASTRAN translator (ACTON) computer program developed to facilitate quick generation of small finite-element mathematical models for use with NASTRAN finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Written in Microsoft Quick-Basic (Version 2.0).

  16. Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients

    Directory of Open Access Journals (Sweden)

    Thomaes Tom

    2012-04-01

    Full Text Available Abstract Background The increasing age of coronary artery disease (CAD patients and the occurrence of sarcopenia in the elderly population accompanied by 'fear of moving' and hospitalization in these patients often results in a substantial loss of skeletal muscle mass and muscle strength. Cardiac rehabilitation can improve exercise tolerance and muscle strength in CAD patients but less data describe eventual morphological muscular changes possibly by more difficult access to imaging techniques. Therefore the aim of this study is to assess and quantify the reliability and validity of an easy applicable method, the ultrasound (US technique, to measure the diameter of rectus femoris muscle in comparison to the muscle dimensions measured with CT scans. Methods 45 older CAD patients without cardiac event during the last 9 months were included in this study. 25 patients were tested twice with ultrasound with a two day interval to assess test-retest reliability and 20 patients were tested twice (once with US and once with CT on the same day to assess the validity of the US technique compared to CT as the gold standard. Isometric and isokinetic muscle testing was performed to test potential zero-order correlations between muscle diameter, muscle volume and muscle force. Results An intraclass correlation coefficient (ICC of 0.97 ((95%CL: 0.92 - 0.99 was found for the test-retest reliability of US and the ICC computed between US and CT was 0.92 (95%CL: 0.81 - 0.97. The absolute difference between both techniques was 0.01 ± 0.12 cm (p = 0.66 resulting in a typical percentage error of 4.4%. Significant zero-order correlations were found between local muscle volume and muscle diameter assessed with CT (r = 0.67, p = 0.001 and assessed with US (r = 0.49, p Conclusions Ultrasound imaging can be used as a valid and reliable measurement tool to assess the rectus femoris muscle diameter in older CAD patients.

  17. A completely CAD/CAM individual transmission device for electronic mandible movement registration.

    Science.gov (United States)

    Krey, Karl-Friedrich; Kordaß, Bernd; Ruge, Sebastian

    The connection of a device for the registration of mandibular movements depends on the coupling of the teeth with a paraocclusal adapter. This is normally done by individualizing a prefabricated metal support, either directly on the patient or in the dental laboratory. The goal was to create an individual paraocclusal adapter by means of additive computer-assisted design/computer-assisted manufacturing (CAD/CAM) procedures, and to test it clinically. Starting from intraoral scans of the maxillary and mandibular teeth, an individual paraocclusal adapter was constructed by combining an adapter piece adapted to the tooth and jaw shape with a prefabricated standard part. This article describes step by step the design using the 3D CAD software, up until production by means of 3D printing. Initial clinical experience is also discussed.

  18. Model-Based Engineering and Manufacturing CAD/CAM Benchmark.; FINAL

    International Nuclear Information System (INIS)

    Domm, T.C.; Underwood, R.S.

    1999-01-01

    The Benchmark Project was created from a desire to identify best practices and improve the overall efficiency and performance of the Y-12 Plant's systems and personnel supporting the manufacturing mission. The mission of the benchmark team was to search out industry leaders in manufacturing and evaluate their engineering practices and processes to determine direction and focus for Y-12 modernization efforts. The companies visited included several large established companies and a new, small, high-tech machining firm. As a result of this effort, changes are recommended that will enable Y-12 to become a more modern, responsive, cost-effective manufacturing facility capable of supporting the needs of the Nuclear Weapons Complex (NWC) into the 21st century. The benchmark team identified key areas of interest, both focused and general. The focus areas included Human Resources, Information Management, Manufacturing Software Tools, and Standards/Policies and Practices. Areas of general interest included Infrastructure, Computer Platforms and Networking, and Organizational Structure. The results of this benchmark showed that all companies are moving in the direction of model-based engineering and manufacturing. There was evidence that many companies are trying to grasp how to manage current and legacy data. In terms of engineering design software tools, the companies contacted were somewhere between 3-D solid modeling and surfaced wire-frame models. The manufacturing computer tools were varied, with most companies using more than one software product to generate machining data and none currently performing model-based manufacturing (MBM) from a common model. The majority of companies were closer to identifying or using a single computer-aided design (CAD) system than a single computer-aided manufacturing (CAM) system. The Internet was a technology that all companies were looking to either transport information more easily throughout the corporation or as a conduit for

  19. CAD in breast imaging. Application in mammography and MR mammography

    International Nuclear Information System (INIS)

    Obenauer, S.; Hermann, K.P.

    2012-01-01

    Computer aided diagnosis systems (CAD-systems) are evaluated in different parts of diagnostic imaging. In breast imaging double reading which is time- and cost spending is necessary. Therefore a lot of studies evaluated the use of CAD-systems in mammography. However the rate of false-positives is too high to implement CAD-systems as double reader in routine work. In the future, improvements in this technique could perhaps change the performance of CAD-systems. (orig.)

  20. CAD-centric Computation Management System for a Virtual TBM

    Energy Technology Data Exchange (ETDEWEB)

    Ramakanth Munipalli; K.Y. Szema; P.Y. Huang; C.M. Rowell; A.Ying; M. Abdou

    2011-05-03

    HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of the analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.

  1. Assessment of the Incremental Benefit of Computer-Aided Detection (CAD) for Interpretation of CT Colonography by Experienced and Inexperienced Readers

    Science.gov (United States)

    Boone, Darren; Mallett, Susan; McQuillan, Justine; Taylor, Stuart A.; Altman, Douglas G.; Halligan, Steve

    2015-01-01

    Objectives To quantify the incremental benefit of computer-assisted-detection (CAD) for polyps, for inexperienced readers versus experienced readers of CT colonography. Methods 10 inexperienced and 16 experienced radiologists interpreted 102 colonography studies unassisted and with CAD utilised in a concurrent paradigm. They indicated any polyps detected on a study sheet. Readers’ interpretations were compared against a ground-truth reference standard: 46 studies were normal and 56 had at least one polyp (132 polyps in total). The primary study outcome was the difference in CAD net benefit (a combination of change in sensitivity and change in specificity with CAD, weighted towards sensitivity) for detection of patients with polyps. Results Inexperienced readers’ per-patient sensitivity rose from 39.1% to 53.2% with CAD and specificity fell from 94.1% to 88.0%, both statistically significant. Experienced readers’ sensitivity rose from 57.5% to 62.1% and specificity fell from 91.0% to 88.3%, both non-significant. Net benefit with CAD assistance was significant for inexperienced readers but not for experienced readers: 11.2% (95%CI 3.1% to 18.9%) versus 3.2% (95%CI -1.9% to 8.3%) respectively. Conclusions Concurrent CAD resulted in a significant net benefit when used by inexperienced readers to identify patients with polyps by CT colonography. The net benefit was nearly four times the magnitude of that observed for experienced readers. Experienced readers did not benefit significantly from concurrent CAD. PMID:26355745

  2. The review of CAD for simulation of microwave devices

    Directory of Open Access Journals (Sweden)

    Drach V.E.

    2017-01-01

    Full Text Available the article is devoted to a brief review of modern CAD for electromagnetic modeling of microwave devices. Five major CAD systems are described in the article: FEKO, μWave Wizard, Sonnet, AWR Microwave Office, HFSS. The main methods are given for each CAD system used for simulation of microwave structures and the main advantages that distinguish its use.

  3. Resin-composite blocks for dental CAD/CAM applications.

    Science.gov (United States)

    Ruse, N D; Sadoun, M J

    2014-12-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials. © International & American Associations for Dental Research.

  4. Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.

    Science.gov (United States)

    McLaughlin, J Bryan; Ramos, Van; Dickinson, Douglas P

    2017-11-14

    To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from

  5. Absorbing CAD system geometries into GEANT

    International Nuclear Information System (INIS)

    Womersley, J.; Dragovitsch, P.; Youssef, S.

    1991-01-01

    The simulation community has for many years discussed the possibility of direct conversion of geometrical detector models from computer- aided design and engineering systems (CAD systems) to the simulation packages (which we shall assume means GEANT). This would allow fast and simultaneous optimization of the physics performance and structural integrity of detector designs. The benefit that this would offer is the avoidance of such problems as the late discovery of the rather thick cryostats in the D-Zero detector. Recent progress in the absorption of CAD geometries into GEANT models is reviewed, including descriptions of the additions to the I-DEAS solid modeller package developed for the EMPACT SSC proposal, the COGENT CAD-to-GEANT interpreter developed by Quantum Research Services, and the OCTAGON package for representing arbitrary shapes in GEANT. Likely future directions of development are described. 2 refs., 7 figs

  6. Report on design rules of μ-tools for standard insert

    DEFF Research Database (Denmark)

    Tosello, Guido; Esmoris, Josa Ignacio; Quadroni, A.

    2011-01-01

    -effectively, especially for micro injection moulding. This particular deliverable has the objective to present the design rules for high performance μ-tools and inserts manufacture based on the new standard manufacturing process chains established during the WP 2.2 work. In particular, the achievable features, surfaces......Tooling is one of the critical stages of the process chain for polymer micro products manufacture and in particular for the COTECH process chain. Therefore, within the scope of SP2 “Tooling”, the WP 2.2 “New tool-making solutions for μ-IM and HE” is designed to investigate, develop and standardize...

  7. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns.

    Science.gov (United States)

    Abdullah, Adil Othman; Tsitrou, Effrosyni A; Pollington, Sarah

    2016-01-01

    This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (PCAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  8. Fracture strength testing of crowns made of CAD/CAM composite resins.

    Science.gov (United States)

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  9. A CAD (Classroom Assessment Design) of a Computer Programming Course

    Science.gov (United States)

    Hawi, Nazir S.

    2012-01-01

    This paper presents a CAD (classroom assessment design) of an entry-level undergraduate computer programming course "Computer Programming I". CAD has been the product of a long experience in teaching computer programming courses including teaching "Computer Programming I" 22 times. Each semester, CAD is evaluated and modified…

  10. Development of integrated CAD system PV-1

    International Nuclear Information System (INIS)

    Miyamoto, Hitoshi; Ogawa, Kazuya; Shibata, Masayoshi.

    1997-01-01

    An integrated CAD system for pressure vessels, such as heat exchangers, drums, towers, jacketed vessels, and tanks, has been developed. The system is operated by MS-DOS personal computers combined in a LAN. Pressure vessel designers can work watching using the computer display because the system automatically manages design work, on a common data base. The project team members in other sections, such as production, cost control, and design, have the same data concurrently. Personal computers unite the 3D CAD system, and the generated design with detail dimensions and shapes is stored in the 3D CAD system automatically. The system has promoted higher design quality and greatly reduced design cost. (author)

  11. MEBT design for C-ADS

    International Nuclear Information System (INIS)

    Geng Huiping; Tang Jingyu; Li Zhihui; Yan Fang; Ouyang Huafu

    2012-01-01

    In proton accelerators, the Medium Energy Beam Transport (MEBT) line is an essential part for transporting and matching the beam from the RFQ to the next type of accelerating structure. The MEBT is also very important in machine commissioning and tuning. The design of the China Accelerator Driven System is making great progress. The C-ADS project is composed of two independent injectors; therefore, two MEBT lines will be designed independently. In this paper, we will give a detailed description of the MEBT design (including parameter selection and beam dynamics calculation) for the injector I of the C-ADS project. (authors)

  12. Design Tools for Integrated Asynchronous Electronic Circuits

    National Research Council Canada - National Science Library

    Martin, Alain

    2003-01-01

    ..., simulation, verification, at the logical and physical levels. Situs has developed a business model for the commercialization of the CAD tools, and has designed the prototype of the tool suite based on this business model and the Caltech approach...

  13. The effect of altered lignin composition on mechanical properties of CINNAMYL ALCOHOL DEHYDROGENASE (CAD) deficient poplars.

    Science.gov (United States)

    Özparpucu, Merve; Gierlinger, Notburga; Burgert, Ingo; Van Acker, Rebecca; Vanholme, Ruben; Boerjan, Wout; Pilate, Gilles; Déjardin, Annabelle; Rüggeberg, Markus

    2018-04-01

    CAD-deficient poplars enabled studying the influence of altered lignin composition on mechanical properties. Severe alterations in lignin composition did not influence the mechanical properties. Wood represents a hierarchical fiber-composite material with excellent mechanical properties. Despite its wide use and versatility, its mechanical behavior has not been entirely understood. It has especially been challenging to unravel the mechanical function of the cell wall matrix. Lignin engineering has been a useful tool to increase the knowledge on the mechanical function of lignin as it allows for modifications of lignin content and composition and the subsequent studying of the mechanical properties of these transgenics. Hereby, in most cases, both lignin composition and content are altered and the specific influence of lignin composition has hardly been revealed. Here, we have performed a comprehensive micromechanical, structural, and spectroscopic analysis on xylem strips of transgenic poplar plants, which are downregulated for cinnamyl alcohol dehydrogenase (CAD) by a hairpin-RNA-mediated silencing approach. All parameters were evaluated on the same samples. Raman microscopy revealed that the lignin of the hpCAD poplars was significantly enriched in aldehydes and reduced in the (relative) amount of G-units. FTIR spectra indicated pronounced changes in lignin composition, whereas lignin content was not significantly changed between WT and the hpCAD poplars. Microfibril angles were in the range of 18°-24° and were not significantly different between WT and transgenics. No significant changes were observed in mechanical properties, such as tensile stiffness, ultimate stress, and yield stress. The specific findings on hpCAD poplar allowed studying the specific influence of lignin composition on mechanics. It can be concluded that the changes in lignin composition in hpCAD poplars did not affect the micromechanical tensile properties.

  14. CAD for CT colonography: toward a preparation-independent scheme

    International Nuclear Information System (INIS)

    Naeppi, J.

    2007-01-01

    Computer-aided detection (CAD) systems can be used to automatically detect and display the locations of polyps and masses in computed tomographic colonography (CTC) data for assisting radiologists' image interpretation. Rapid technical advancements over the last few years have established a fundamental CAD scheme for CTC that includes the steps of colon extraction, polyp detection, and false-positive (FP) reduction. Several CAD prototype systems have demonstrated clinically acceptable high polyp detection sensitivity with relatively few FP detections in cathartic CTC, and observer studies have demonstrated the potential benefit of such systems in improving the accuracy and consistency of radiologists' detection performance. Some CAD prototype systems have also demonstrated promising performance in reduced cathartic and non-cathartic CTC. Recent advancements suggest that CAD systems can soon be expected to provide a preparation-independent scheme that can yield consistently high detection sensitivity with moderately low FP rate not only with cathartic CTC protocols but over a wide range of cathartic, reduced cathartic, and non-cathartic CTC protocols. (orig.)

  15. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Directory of Open Access Journals (Sweden)

    Adil Othman ABDULLAH

    Full Text Available ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group. The crowns were divided into four groups (n=10, Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99 µm, PEEK 46.75 (±8.26 µm, Telio CAD-Temp 56.10 (±5.65 µm, and Protemp™4 193.07(±35.96 µm (P0.05. Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  16. Development of Pipeline Database and CAD Model for Selection of Core Security Zone in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Choi, Seong Soo; Kwon, Tae Gyun; Baek, Hun Hyun; Kwon, Min Jin

    2008-07-01

    The objective of the project is to develop the pipeline database which can be used for selection of core security zones considering safety significance of pipes and to develop CAD model for 3-dimensional visualization of core security zones, for the purpose of minimizing damage and loss, enforcing security and protection on important facilities, and improving plant design preparing against emergency situations such as physical terrors in nuclear power plants. In this study, the pipeline database is developed for selection of core security zones considering safety significance of safety class 1 and 2 pipes. The database includes the information on 'pipe-room information-surrogate component' mapping, initiating events which may occur and accident mitigation functions which may be damaged by the pipe failure, and the drawing information related to 2,270 pipe segments of 30 systems. For the 3-dimensional visualization of core security zones, the CAD models on the containment building and the auxiliary building are developed using 3-D MAX tool and the demo program which can visualize the direct-X model converted from the 3-D MAX model is also developed. In addition to this, the coordinate information of all the buildings and their rooms is generated using AUTO CAD tool in order to be used as an input for 3-dimensional browsing of the VIP program

  17. Machining variability impacts on the strength of a 'chair-side' CAD-CAM ceramic.

    LENUS (Irish Health Repository)

    Addison, Owen

    2012-08-01

    To develop a novel methodology to generate specimens for bi-axial flexure strength (BFS) determination from a \\'chair-side\\' CAD-CAM feldspathic ceramic with surface defect integrals analogous to the clinical state. The hypotheses tested were: BFS and surface roughness (R(a)) are independent of machining variability introduced by the renewal or deterioration of form-grinding tools and that a post-machining annealing cycle would significantly modify BFS.

  18. Integrating Real-Time Room Acoustics Simulation into a CAD Modeling Software to Enhance the Architectural Design Process

    Directory of Open Access Journals (Sweden)

    Sönke Pelzer

    2014-04-01

    Full Text Available For architects, real-time 3D visual rendering of CAD-models is a valuable tool. The architect usually perceives the visual appearance of the building interior in a natural and realistic way during the design process. Unfortunately this only emphasizes the role of the visual appearance of a building, while the acoustics often remain disregarded. Controlling the room acoustics is not integrated into most architects’ workflows—due to a lack of tools. The present contribution describes a newly developed plug-in for adding an adequate 3D-acoustics feedback to the architect. To present intuitively the acoustical effect of the current design project, the plug-in uses real-time audio rendering and 3D-reproduction. The room acoustics of the design can be varied by modifying structural shapes as well as by changing the material selection. In addition to the audio feedback, also a visualization of important room acoustics qualities is provided by displaying color-coded maps inside the CAD software.

  19. The CAD concept for stellarator-type magnetic systems

    International Nuclear Information System (INIS)

    Vorobyova, V.P.; Martynov, S.A.; Khazhmuradov, M.A.

    2002-01-01

    The paper describes the computer-aided design (CAD) concept for stellarator-type magnetic systems. Consideration is given to the main peculiarities, principles, and dialog organization and design stages of the CAD. The practical realization of the concept is illustrated by specific examples

  20. The application of CAD / CAM technology in Dentistry

    Science.gov (United States)

    Susic, I.; Travar, M.; Susic, M.

    2017-05-01

    Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.

  1. Innovative three-dimensional neutronics analyses directly coupled with cad models of geometrically complex fusion systems

    International Nuclear Information System (INIS)

    Sawan, M.; Wilson, P.; El-Guebaly, L.; Henderson, D.; Sviatoslavsky, G.; Bohm, T.; Kiedrowski, B.; Ibrahim, A.; Smith, B.; Slaybaugh, R.; Tautges, T.

    2007-01-01

    Fusion systems are, in general, geometrically complex requiring detailed three-dimensional (3-D) nuclear analysis. This analysis is required to address tritium self-sufficiency, nuclear heating, radiation damage, shielding, and radiation streaming issues. To facilitate such calculations, we developed an innovative computational tool that is based on the continuous energy Monte Carlo code MCNP and permits the direct use of CAD-based solid models in the ray-tracing. This allows performing the neutronics calculations in a model that preserves the geometrical details without any simplification, eliminates possible human error in modeling the geometry for MCNP, and allows faster design iterations. In addition to improving the work flow for simulating complex 3- D geometries, it allows a richer representation of the geometry compared to the standard 2nd order polynomial representation. This newly developed tool has been successfully tested for a detailed 40 degree sector benchmark of the International Thermonuclear Experimental Reactor (ITER). The calculations included determining the poloidal variation of the neutron wall loading, flux and nuclear heating in the divertor components, nuclear heating in toroidal field coils, and radiation streaming in the mid-plane port. The tool has been applied to perform 3-D nuclear analysis for several fusion designs including the ARIES Compact Stellarator (ARIES-CS), the High Average Power Laser (HAPL) inertial fusion power plant, and ITER first wall/shield (FWS) modules. The ARIES-CS stellarator has a first wall shape and a plasma profile that varies toroidally within each field period compared to the uniform toroidal shape in tokamaks. Such variation cannot be modeled analytically in the standard MCNP code. The impact of the complex helical geometry and the non-uniform blanket and divertor on the overall tritium breeding ratio and total nuclear heating was determined. In addition, we calculated the neutron wall loading variation in

  2. User productivity as a function of AutoCAD interface design.

    Science.gov (United States)

    Mitta, D A; Flores, P L

    1995-12-01

    Increased operator productivity is a desired outcome of user-CAD interaction scenarios. Two objectives of this research were to (1) define a measure of operator productivity and (2) empirically investigate the potential effects of CAD interface design on operator productivity, where productivity is defined as the percentage of a drawing session correctly completed per unit time. Here, AutoCAD provides the CAD environment of interest. Productivity with respect to two AutoCAD interface designs (menu, template) and three task types (draw, dimension, display) was investigated. Analysis of user productivity data revealed significantly higher productivity under the menu interface condition than under the template interface condition. A significant effect of task type was also discovered, where user productivity under display tasks was higher than productivity under the draw and dimension tasks. Implications of these results are presented.

  3. Trend and application of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-09-01

    This report is about trend and application of CAD/CAM system, giving descriptions of computer aided design which helps construction, engineering and drafting tasks. It also tells of computer aided manufacturing related general design of manufactures, which includes process design, production management, decision of work technology, processing. The need and application of CAD/CAM system is increasing more and more for industry each area.

  4. Integrated CAD/CAE for nuclear power plants

    International Nuclear Information System (INIS)

    Lecoq, P.; Lachat, J.C.

    1987-01-01

    The size of the French nuclear power program has led both EDF and Framatome to equip themselves progressively with management software, computer-assisted design (CAD) systems, and computer-assisted engineering (CAE) systems. The nature of the projects and of the respective activities of EDF and Framatome determined the essential specifications of these computerized systems. EDF and Framatome have pooled their CAD/CAE efforts in a joint venture (Groupement d'Interet Economique) called GIAO, set up in 1985 by EDF and Aquitaine Systeme (a subsidiary of Framatome and Elf Aquitaine). GIAO's ambition is to become a pole of French CAD/CAE efforts and to foster progress in integrated computer-assisted engineering, by enlarging the synergy of EDF and Framatome in this field to other enterprises that participate in design and construction of complex industrial plants

  5. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Destounis, Stamatia [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States); University of Rochester, School of Medicine and Dentistry, Rochester, NY (United States); Hanson, Sarah; Morgan, Renee; Murphy, Philip; Somerville, Patricia; Seifert, Posy; Andolina, Valerie; Arieno, Andrea; Skolny, Melissa; Logan-Young, Wende [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States)

    2009-06-15

    A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRADS {sup registered} category 1 digital mammography examinations were randomly identified to serve as a comparative normal/control population. Data included patient age; BIRADS {sup registered} breast density; lesion type, size, and visibility; number, type, and location of CAD marks per image; CAD ability to mark lesions; needle core and surgical pathologic correlation. The CAD lesion/case sensitivity of 87% (n=39), image sensitivity of 69% (n=31) for mediolateral oblique view and 78% (n=35) for the craniocaudal view was found. The average false positive rate in 44 normal screening cases was 2.0 (range 1-8). The 2.0 figure is based on 88 reported false positive CAD marks in 44 normal screening exams: 98% (n=44) lesions proceeded to excision; initial pathology upgraded at surgical excision from in situ to invasive disease in 24% (n=9) lesions. CAD demonstrated potential to detect mammographically visible cancers in standard projections for all lesion types. (orig.)

  6. Virtual colonoscopy: effect of computer-assisted detection (CAD) on radiographer performance

    International Nuclear Information System (INIS)

    Burling, D.; Moore, A.; Marshall, M.; Weldon, J.; Gillen, C.; Baldwin, R.; Smith, K.; Pickhardt, P.; Honeyfield, L.; Taylor, S.

    2008-01-01

    Aim: To investigate the effect of a virtual colonoscopy (VC) computed-assisted detection (CAD) system on polyp detection by trained radiographers. Materials and methods: Four radiographers trained in VC interpretation and utilization of CAD systems read a total of 62 endoscopically validated VC examinations containing 150 polyps (size range 5-50 mm) in four sessions, recording any polyps found and the examination interpretation time, first without and then with the addition of CAD as a 'second reader'. After a temporal separation of 6 weeks to reduce recall bias, VC examinations were re-read using 'concurrent reader' CAD. Interpretation times, polyp detection, and number of false-positives were compared between the different reader paradigms using paired t and paired exact tests. Results: Overall, use of 'second reader' CAD significantly improved polyp detection by 12% (p < 0.001, CI 6%,17%)) from 48 to 60%. There was no significant improvement using CAD as a concurrent reader (p = 0.20; difference of 7%, CI -3%, 16%) and no significant overall difference in recorded false-positives with second reader or concurrent CAD paradigms compared with unassisted reading (p = 0.25 and 0.65, respectively). The mean interpretation time was 21.7 min for unassisted reading, 29.6 (p < 0.001) min for second reader and 19.1 min (p = 0.12) for concurrent reading paradigms. Conclusion: CAD, when used as a second reader, can significantly improve radiographer reading performance with only a moderate increase in interpretation times

  7. CAD-CAM printed circuit board design

    Science.gov (United States)

    Agy, W. E.

    A step-by-step procedure for a printed circuit design achieved by CAD is presented. The operator at the interactive CRT station moves a stylus across a graphics tablet and intersperses commands which result in computer-generated pictorial forms on the screen that were drawn on the pad. Standard symbols are used for commands allowing, for instance, connections to be made of specific types in certain locations, which can be automatically edited from a materials list. An entire network of drawn lines can be referenced by a signal name for recall, and a finished circuit schematic can be checked for designs rules compliance, including fault reporting in terms of designator/pin number. A map may be present delineating the boundaries of the circuitry area, and previously completed circuitry segments can be recalled for piece-by-piece assembly of the circuit board.

  8. A multi-user selective undo/redo approach for collaborative CAD systems

    Directory of Open Access Journals (Sweden)

    Yuan Cheng

    2014-04-01

    Full Text Available The engineering design process is a creative process, and the designers must repeatedly apply Undo/Redo operations to modify CAD models to explore new solutions. Undo/Redo has become one of most important functions in interactive graphics and CAD systems. Undo/Redo in a collaborative CAD system is also very helpful for collaborative awareness among a group of cooperative designers to eliminate misunderstanding and to recover from design error. However, Undo/Redo in a collaborative CAD system is much more complicated. This is because a single erroneous operation is propagated to other remote sites, and operations are interleaved at different sites. This paper presents a multi-user selective Undo/Redo approach in full distributed collaborative CAD systems. We use site ID and State Vectors to locate the Undo/Redo target at each site. By analyzing the composition of the complex CAD model, a tree-like structure called Feature Combination Hierarchy is presented to describe the decomposition of a CAD model. Based on this structure, the dependency relationship among features is clarified. B-Rep re-evaluation is simplified with the assistance of the Feature Combination Hierarchy. It can be proven that the proposed Undo/Redo approach satisfies the intention preservation and consistency maintenance correctness criteria for collaborative systems.

  9. Nuclear cardiology between echocardiography and coronary angiography in the management of CAD

    International Nuclear Information System (INIS)

    Anger, K.

    1996-01-01

    In managing coronary artery disease there are clearly posed questions: In diagnosis to assess presence, extent and severity of CAD, in therapy to assess prognosis and benefit of PTCA and ACVB. Coronary angiography remains the gold standard for assessing coronary stenosis, function imaging - stress echocardiography - and myocardial perfusion imaging (MIP) are assessing ischemia, i.e. extent and severity of CAD meaning prognosis and benefit of invasive therapy. The costs of echo /MPI/ catherization are 1 : 2: 6. When the essential conditions in non invasive investigations are observed - exact indication, maximal quality, evaluation of efficacy D, M and O - equal acceptance of all methods by cardiologists is attainable and there will be a great potential of cost saving in invasive diagnostics and therapy. The part of MPI is assessed in evaluating myocardium viability and benefit of invasive therapy, in the diagnosis of ischemia and evaluation of outcome MPI eventually will be replaced by stress echocardiography in future. (orig.) [de

  10. Incorporation of CAD/CAM Restoration Into Navy Dentistry

    Science.gov (United States)

    2017-09-26

    CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...this time by allowing for rapid scanning, designing , development, and production of dental restorations. Using this technology gives dentists the

  11. Longevity of Single-Tooth All-Ceramic CAD/CAM Restorations: A Meta-Analysis

    Science.gov (United States)

    2013-07-01

    to the application of CAD/CAM technology in dentistry . The initial monetary investment for the equipment is significant. Systems currently on the...CURRENT DENTAL CAD/CAM SYSTEMS Current CAD/CAM systems in dentistry include: CEREC (CEramic REConstruction) and CEREC Acquisition Center (AC) with...of Adhesive Dentistry , 1 (3), 255- 265. 42     Bindl A, & Mörmann W. (2002). An up to 5-year clinical evaluation of posterior In- Ceram CAD

  12. Design of parametric software tools

    DEFF Research Database (Denmark)

    Sabra, Jakob Borrits; Mullins, Michael

    2011-01-01

    The studies investigate the field of evidence-based design used in architectural design practice and propose a method using 2D/3D CAD applications to: 1) enhance integration of evidence-based design knowledge in architectural design phases with a focus on lighting and interior design and 2) assess...... fulfilment of evidence-based design criterion regarding light distribution and location in relation to patient safety in architectural health care design proposals. The study uses 2D/3D CAD modelling software Rhinoceros 3D with plug-in Grasshopper to create parametric tool prototypes to exemplify...... the operations and functions of the design method. To evaluate the prototype potentials, surveys with architectural and healthcare design companies are conducted. Evaluation is done by the administration of questionnaires being part of the development of the tools. The results show that architects, designers...

  13. Transcriptome-wide identification and characterization of CAD isoforms specific for podophyllotoxin biosynthesis from Podophyllum hexandrum.

    Science.gov (United States)

    Bhattacharyya, Dipto; Hazra, Saptarshi; Banerjee, Anindyajit; Datta, Riddhi; Kumar, Deepak; Chakrabarti, Saikat; Chattopadhyay, Sharmila

    2016-09-01

    Podophyllotoxin (ptox) is a therapeutically important lignan derived from Podophyllum hexandrum and is used as a precursor for the synthesis of anticancer drugs etoposide, teniposide and etopophose. In spite of its enormous economic significance, genomic information on this endangered medicinal herb is scarce. We have performed de novo transcriptome analysis of methyl jasmonate (MeJA)-treated P. hexandrum cell cultures exhibiting enhanced ptox accumulation. The results revealed the maximum up-regulation of several isoforms of cinnamyl alcohol dehydrogenase (CAD). CAD catalyzes the synthesis of coniferyl alcohol and sinapyl alcohol from coniferaldehyde (CAld) and sinapaldehyde respectively. Coniferyl alcohol can produce both lignin and lignan while sinapyl alcohol produces only lignin. To isolate the CAD isoforms favoring ptox, we deduced full length cDNA sequences of four CAD isoforms: PhCAD1, PhCAD2, PhCAD3 and PhCAD4 from the contigs of the transcriptome data. In vitro enzyme assays indicated a higher affinity for CAld over sinapaldehyde for each isoform. In silico molecular docking analyses also suggested that PhCAD3 has a higher binding preference with CAld over sinapaldehyde, followed by PhCAD4, PhCAD2, and PhCAD1, respectively. The transgenic cell cultures overexpressing these isoforms independently revealed that PhCAD3 favored the maximum accumulation of ptox as compared to lignin followed by PhCAD4 and PhCAD2, whereas, PhCAD1 favored both equally. Together, our study reveals transcriptome-wide identification and characterization of ptox specific CAD isoforms from P. hexandrum. It provides a useful resource for future research not only on the ptox biosynthetic pathway but on overall P. hexandrum, an endangered medicinal herb with immense therapeutic importance.

  14. Marginal Fit Comparison of CAD/CAM Crowns Milled from Two Different Materials.

    Science.gov (United States)

    Azarbal, Atousa; Azarbal, Mohsen; Engelmeier, Robert L; Kunkel, Thomas C

    2017-11-16

    To evaluate the marginal fit of CAD/CAM copings milled from hybrid ceramic (Vita Enamic) blocks and lithium disilicate (IPS e.max CAD) blocks, and to evaluate the effect of crystallization firing on the marginal fit of lithium disilicate copings. A standardized metal die with a 1-mm-wide shoulder finish line was imaged using the CEREC AC Bluecam. The coping was designed using CEREC 3 software. The design was used to fabricate 15 lithium disilicate and 15 hybrid ceramic copings. Design and milling were accomplished by one operator. The copings were seated on the metal die using a pressure clamp with a uniform pressure of 5.5 lbs. A Macroview Microscope (14×) was used for direct viewing of the marginal gap. Four areas were imaged on each coping (buccal, distal, lingual, mesial). Image analysis software was used to measure the marginal gaps in μm at 15 randomly selected points on each of the four surfaces. A total of 60 measurements were made per specimen. For lithium disilicate copings the measurements for marginal gap were made before and after crystallization firing. Data were analyzed using paired t-test and Kruskal-Wallis test. The overall mean difference in marginal gap between the hybrid ceramic and crystallized lithium disilicate copings was statistically significant (p marginal gaps were measured for crystallized lithium disilicate copings. The overall mean difference in marginal gap before and after firing (precrystallized and crystallized lithium disilicate copings) showed an average of 62 μm increase in marginal gap after firing. This difference was also significant (p marginal gap discrepancy when comparing hybrid ceramic and lithium disilicate CAD/CAM crowns. Also crystallization firing can result in a significant increase in the marginal gap of lithium disilicate CAD/CAM crowns. © 2017 by the American College of Prosthodontists.

  15. Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites.

    Science.gov (United States)

    Stawarczyk, Bogna; Liebermann, Anja; Eichberger, Marlis; Güth, Jan-Frederik

    2015-03-01

    To determine the mechanical and optical properties of CAD/CAM composites (LAVA Ultimate, Cerasmart, Shofu Block and two exp. CAD/CAM composites), a hybrid material (VITA Enamic), a leucite (IPS Empress CAD) and a lithium disilicate glass-ceramic (IPS e.max CAD). Three-point flexural strength (FS) was investigated according ISO 6872:2008 (N=240/n=30). Two-body wear (TBW) was analyzed in a chewing simulator (1,200,000 cycles, 50N, 5°/55°C) using human teeth as antagonists (N=120/n=15). Quantitative analysis of wear was carried out with a 3D-scanner and associated matching software. Discoloration rate (DR) after 14 days of storage in cress, curry, red wine, and distilled water (N=384/n=12), and translucency (T) (N=384/n=48) of CAD/CAM materials were measured in a spectrophotometer (400-700nm wavelength). Data were analyzed using two-/one-way ANOVA with Scheffé post-hoc test, Kruskal-Wallis-H test, and linear mixed models (α=0.05). IPS e.max CAD showed the highest FS (pCAD/CAM composites (exception: Shofu Block). The lowest FS showed VITA Enamic and IPS Empress CAD (pCAD, VITA Enamic, exp. CAD/CAM composite 2, followed by IPS e.max presented lower material TBW than the remaining CAD/CAM materials (pcurry>cress>distilled water) exerted the highest influence on DR (pCAD/CAM material. Glass-ceramics showed lower DR than CAD/CAM composites (pCAD/CAM composites presented moderate FS, high T and antagonist friendly behavior. Glass-ceramic demonstrated the most favorable DR and lowest TBW on the material side. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Interstitial lung disease associated with collagen vascular disorders: disease quantification using a computer-aided diagnosis tool

    Energy Technology Data Exchange (ETDEWEB)

    Marten, K.; Engelke, C. [University Hospital of Goettingen, Department of Radiology, Goettingen (Germany); Dicken, V. [MeVis Research GmbH, Bremen (Germany); Kneitz, C. [University Hospital of Wuerzburg, Dept. of Rheumatology and Clinical Immunology, Medizinische Klinik and Poliklinik, Wuerzburg (Germany); Hoehmann, M.; Kenn, W.; Hahn, D. [University Hospital of Wuerzburg, Department of Radiology, Wuerzburg (Germany)

    2009-02-15

    The purpose of this study was to evaluate a computer-aided diagnosis (CAD) tool compared to human observers in quantification of interstitial lung disease (ILD) in patients with collagen-vascular disorders. A total of 52 patients with rheumatoid arthritis (n=24), scleroderma (n=14) and systemic lupus erythematosus (n=14) underwent thin-section CT. Two independent observers assessed the extent of ILD (EoILD), reticulation (EoRet) and ground-glass opacity (EoGGO). CAD assessed EoILD twice. Pulmonary function tests were obtained. Statistical evaluation used 95% limits of agreement and linear regression analysis. CAD correlated well with diffusing capacity (DL{sub CO}) (R=-0.531, P<0.0001) and moderately with forced vital capacity (FVC) (R=-0.483, P=0.0008). There was close correlation between CAD and the readers (EoILD vs. CAD: R=0.716, P<0.0001; EoRet vs. CAD: R=0.69, P<0.0001). Subgroup analysis including patients with minimal EoGGO (<15%) strengthened the correlations between CAD and the readers, readers and PFT, and CAD and PFT. EoILD by readers correlated strongly with DL{sub CO} (R=-0.705, P<0.0001) and moderately with FVC (R=-0.559, P=0.0002). EoRet correlated closely with DL{sub CO} and moderately with FVC (DL{sub CO}: R=-0.663; FVC: R=-0.436; P{<=}0.005). The CAD system is a promising tool for ILD quantification, showing close correlation with human observers and physiologic impairment. (orig.)

  17. The dynamic interaction of order flows and the CAD/USD exchange rate

    OpenAIRE

    Nikola Gradojevic; Christopher J. Neely

    2008-01-01

    We explore the relationship between disaggregated order flow, the Canada/U.S. dollar (CAD/USD) market and U.S. macroeconomic announcements. Three types of CAD order flow and the CAD/USD are cointegrated. Financial order flow appears to contemporaneously drive the CAD/USD while commercial order flow seems to contemporaneously respond to exchange rate movements. Past order flow and lagged exchange rates strongly explain most types of order flow. Despite this predictability and the contemporaneo...

  18. Optical properties of CAD-CAM ceramic systems.

    Science.gov (United States)

    Della Bona, Alvaro; Nogueira, Audrea D; Pecho, Oscar E

    2014-09-01

    To evaluate the direct transmittance (T%), translucency, opacity and opalescence of CAD-CAM ceramic systems and the correlation between the translucency parameter (TP) and the contrast ratio (CR). Specimens of shades A1, A2 and A3 (n=5) were fabricated from CAD-CAM ceramic blocks (IPS e.max(®) CAD HT and LT, IPS Empress(®) CAD HT and LT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. A spectrophotometer (Lambda 20) was used to measure T% on the wavelength range of 400-780nm. Another spectrophotometer (VITA Easyshade(®) Advance) was used to measure the CIE L(*)a(*)b(*) coordinates and the reflectance value (Y) of samples on white and black backgrounds. TP, CR and the opalescence parameter (OP) were calculated. Data were statistically analysed using VAF (variance accounting for) coefficient with Cauchy-Schwarz inequality, one-way ANOVA, Tukey's test, Bonferroni correction and Pearson's correlation. T% of some ceramic systems is dependent on the wavelength. The spectral behaviour showed a slight and constant increase in T% up to approximately 550nm, then some ceramics changed the behaviour as the wavelength gets longer. TP and CR values ranged, respectively, from 16.79 to 21.69 and from 0.52 to 0.64 (r(2)=-0.97). OP values ranged from 3.01 to 7.64. The microstructure of CAD-CAM ceramic systems influenced the optical properties. TP and CR showed a strong correlation for all ceramic systems evaluated. Yet, all ceramics showed some degree of light transmittance. In addition to shade, this study showed that other optical properties influence on the natural appearance of dental ceramics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Cam Design Projects in an Advanced CAD Course for Mechanical Engineers

    Science.gov (United States)

    Ault, H. K.

    2009-01-01

    The objective of this paper is to present applications of solid modeling aimed at modeling of complex geometries such as splines and blended surfaces in advanced CAD courses. These projects, in CAD-based Mechanical Engineering courses, are focused on the use of the CAD system to solve design problems for applications in machine design, namely the…

  20. Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA-based polymers used for digital 3D complete dentures.

    Science.gov (United States)

    Arslan, Mustafa; Murat, Sema; Alp, Gulce; Zaimoglu, Ali

    2018-01-01

    The objectives of this in vitro study were to evaluate the flexural strength (FS), surface roughness (Ra), and hydrophobicity of polymethylmethacrylate (PMMA)-based computer-aided design/computer-aided manufacturing (CAD/CAM) polymers and to compare the properties of different CAD/CAM PMMA-based polymers with conventional heat-polymerized PMMA following thermal cycling. Twenty rectangular-shaped specimens (64 × 10 × 3.3 mm) were fabricated from three CAD/CAM PMMA-based polymers (M-PM Disc [M], AvaDent Puck Disc [A], and Pink CAD/CAM Disc Polident [P], and one conventional heat-polymerized PMMA (Promolux [C]), according to ISO 20795-1:2013 standards. The specimens were divided into two subgroups (n = 10), a control and a thermocycled group. The specimens in the thermocycled group were subjected to 5000 thermal cycling procedures (5 to 55°C; 30 s dwell times). The Ra value was measured using a profilometer. Contact angle (CA) was assessed using the sessile drop method to evaluate surface hydrophobicity. In addition, the FS of the specimens was tested in a universal testing machine at a crosshead speed of 1.0 mm/min. Surface texture of the materials was assessed using scanning electron microscope (SEM). The data were analyzed using two-way analysis of variance (ANOVA), followed by Tukey's HSD post-hoc test (α CAD/CAM PMMA-based polymers showed significantly higher FS than conventional heat-polymerized PMMA for each group (P CAD/CAM PMMA-based polymer [P] showed the highest FS, whereas conventional PMMA [C] showed the lowest FS before and after thermal cycling (P 0.05). In the thermocycled group, the lowest Ra value was observed for CAD/CAM PMMA-based polymer [M] (P CAD/CAM PMMA-based polymers [A] and [P], and conventional PMMA [C] had similar Ra values (P > 0.05). Conventional PMMA [C] had a significantly lower CA and consequently lower hydrophobicity compared to the CAD/CAM polymers in the control group (P CAD/CAM PMMA-based polymer [A] and conventional PMMA [C

  1. Association of rs662799 in APOA5 with CAD in Chinese Han population.

    Science.gov (United States)

    Chen, Hua; Ding, Shifang; Zhou, Mi; Wu, Xiayin; Liu, Xi; Wu, Yun; Liu, Dechao

    2018-01-08

    CAD (Coronary Artery Disease) is a complex disease that influenced by various environmental and genetic factors. Previous studies have found many single nucleotide polymorphisms (SNPs) associated with the risk of CAD occurrence. However, the results are inconsistent. In this study, we aim to investigate genetic etiology in Chinese Han population by analysis of 7 SNPs in lipid metabolism pathway that previously has been reported to be associated with CAD. A total of 631 samples were used in this study, including 435 CAD cases and 196 normal healthy controls. SNP genotyping were conducted via multiplex PCR amplifying followed by NGS (next-generation sequencing). Rs662799 in APOA5 (Apolipoprotein A5) gene was associated with CAD in Chinese Han population (Odds-ratio = 1.374, P-value = 0.03). No significant association was observed between the rest of SNPs and CAD. Stratified association analysis revealed rs5882 was associated with CAD in non-hypertension group (Odds-ratio = 1.593, P-value = 0.023). Rs1800588 was associated with CAD in smoking group (Odds-ratio = 1.603, P-value = 0.035). The minor allele of rs662799 was the risk factor of CAD occurrences in Chinese Han population.

  2. CAD-centric Computation Management System for a Virtual TBM. Final Report

    International Nuclear Information System (INIS)

    Munipalli, Ramakanth; Szema, K.Y.; Huang, P.Y.; Rowell, C.M.; Ying, A.; Abdou, M.

    2011-01-01

    HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of the analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.

  3. GPU-accelerated depth map generation for X-ray simulations of complex CAD geometries

    Science.gov (United States)

    Grandin, Robert J.; Young, Gavin; Holland, Stephen D.; Krishnamurthy, Adarsh

    2018-04-01

    Interactive x-ray simulations of complex computer-aided design (CAD) models can provide valuable insights for better interpretation of the defect signatures such as porosity from x-ray CT images. Generating the depth map along a particular direction for the given CAD geometry is the most compute-intensive step in x-ray simulations. We have developed a GPU-accelerated method for real-time generation of depth maps of complex CAD geometries. We preprocess complex components designed using commercial CAD systems using a custom CAD module and convert them into a fine user-defined surface tessellation. Our CAD module can be used by different simulators as well as handle complex geometries, including those that arise from complex castings and composite structures. We then make use of a parallel algorithm that runs on a graphics processing unit (GPU) to convert the finely-tessellated CAD model to a voxelized representation. The voxelized representation can enable heterogeneous modeling of the volume enclosed by the CAD model by assigning heterogeneous material properties in specific regions. The depth maps are generated from this voxelized representation with the help of a GPU-accelerated ray-casting algorithm. The GPU-accelerated ray-casting method enables interactive (> 60 frames-per-second) generation of the depth maps of complex CAD geometries. This enables arbitrarily rotation and slicing of the CAD model, leading to better interpretation of the x-ray images by the user. In addition, the depth maps can be used to aid directly in CT reconstruction algorithms.

  4. Rapid proto typing of dental prosthesis by means of a feldspathic glass composite mixed with muscovite mica via CAD/CAM; Prototipagem rapida de proteses dentarias por meio de um composito de vidro feldspatico misturado com mica moscovita via CAD/CAM

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Junior, E.S.; Gomes Junior, G.G.; Fonseca, M.D.; Moraes, E.E.S.; Ogasawara, T., E-mail: edil@metalmat.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Metalurgica e Materiais

    2010-07-01

    The work consists in the use and integration of CAD/CAM tools as a process of design and manufacture of a rapid prototyping of dental prosthesis by machining using a CNC milling machine. The material machined to obtain the dental prosthesis were cylindrical blocks of a Feldspathic glass composite mixed with muscovite mica in various percentages (15%, 40% and 80%), which was resigned under biaxial pressing and sintered in vacuum at temperatures from 800 to 1100 deg C. The composite was characterized by XRD and SEM. The results show that increasing the crystallization of leucite is consequent to the temperature increase, and that the use of CAD/CAM system using a CNC milling machine is feasible to obtain dental prosthesis. (author)

  5. Acceleration techniques for the direct use of CAD-based geometry in fusion neutronics analysis

    International Nuclear Information System (INIS)

    Wilson, Paul P.H.; Tautges, Timothy J.; Kraftcheck, Jason A.; Smith, Brandon M.; Henderson, Douglass L.

    2010-01-01

    The Direct Accelerated Geometry Monte Carlo (DAGMC) software library offers a unique approach to performing neutronics analysis on CAD-based geometries of fusion systems. By employing a number of acceleration techniques, the ray-tracing operations that are fundamental to Monte Carlo radiation transport are implemented efficiently for direct use on the CAD-based solid model, eliminating the need to translate to the native Monte Carlo input language. By forming hierarchical trees of oriented bounding boxes, one for each facet that results from a high-fidelity tessellation of the model, the ray-tracing performance is adequate to permit detailed analysis of large complex systems. In addition to the reduction in human effort and improvement in quality assurance that is found in the translation approaches, the DAGMC approach also permits the analysis of geometries with higher order surfaces that cannot be represented by many native Monte Carlo radiation transport tools. The paper describes the various acceleration techniques and demonstrates the resulting capability in a real fusion neutronics analysis.

  6. 3D CAD model of the subcritical nuclear reactor of IPN

    International Nuclear Information System (INIS)

    Pahuamba V, F. de J.; Delfin L, A.; Gomez T, A.; Ibarra R, G.; Del Valle G, E.; Sanchez R, A.

    2016-09-01

    The three-dimensional (3D) CAD model of the subcritical reactor Chicago model 9000 of Instituto Politecnico Nacional (IPN) allows obtaining a 3D view with the dimensions of each of its components, such as: natural uranium cylindrical rods, fuel elements, hexagonal reactor core arrangement, cylindrical stainless steel tank containing the core, fuel element support grids and reactor water cleaning system. As a starting point for the development of the model, the Chicago model 9000 subcritical reactor manual provided by the manufacturer was used, the measurement and verification of the components to adapt the geometric, physical and mechanical characteristics was carried out and materials standards were used to obtain a design that allows to elaborate a new manual according to the specifications. In addition, the 3D models of the building of the Advanced Physics Laboratory, neutron generator, cobalt source and the corridors connecting to the subcritical reactor facility were developed, allowing an animated ride, developed by computer-aided design software. The manual provided by the company Nuclear Chicago, dates from the year 1959 and presents diverse deviations in the design and dimensions of the reactor components. The model developed; in addition to supporting the development of the new manual represents a learning tool to visualize the reactor components. (Author)

  7. TEACHING CAD PROGRAMMING TO ARCHITECTURE STUDENTS

    Directory of Open Access Journals (Sweden)

    Maria Gabriela Caffarena CELANI

    2008-11-01

    Full Text Available The objective of this paper is to discuss the relevance of including the discipline of computer programming in the architectural curriculum. To do so I start by explaining how computer programming has been applied in other educational contexts with pedagogical success, describing Seymour Papert's principles. After that, I summarize the historical development of CAD and provide three historical examples of educational applications of computer programming in architecture, followed by a contemporary case that I find of particular relevance. Next, I propose a methodology for teaching programming for architects that aims at improving the quality of designs by making their concepts more explicit. This methodology is based on my own experience teaching computer programming for architecture students at undergraduate and graduate levels at the State University of Campinas, Brazil. The paper ends with a discussion about the role of programming nowadays, when most CAD software are user-friendly and do not require any knowledge of programming for improving performance. I conclude that the introduction of programming in the CAD curriculum within a proper conceptual framework may transform the concept of architectural education. Key-words: Computer programming; computer-aided design; architectural education.

  8. AutoCAD-To-GIFTS Translator Program

    Science.gov (United States)

    Jones, Andrew

    1989-01-01

    AutoCAD-to-GIFTS translator program, ACTOG, developed to facilitate quick generation of small finite-element models using CASA/GIFTS finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Geometric entities recognized by ACTOG include points, lines, arcs, solids, three-dimensional lines, and three-dimensional faces. From this information, ACTOG creates GIFTS SRC file, which then reads into GIFTS preprocessor BULKM or modified and reads into EDITM to create finite-element model. SRC file used as is or edited for any number of uses. Written in Microsoft Quick-Basic (Version 2.0).

  9. Applying open source data visualization tools to standard based medical data.

    Science.gov (United States)

    Kopanitsa, Georgy; Taranik, Maxim

    2014-01-01

    Presentation of medical data in personal health records (PHRs) requires flexible platform independent tools to ensure easy access to the information. Different backgrounds of the patients, especially elder people require simple graphical presentation of the data. Data in PHRs can be collected from heterogeneous sources. Application of standard based medical data allows development of generic visualization methods. Focusing on the deployment of Open Source Tools, in this paper we applied Java Script libraries to create data presentations for standard based medical data.

  10. Deactivation of the E. coli pH stress sensor CadC by cadaverine.

    Science.gov (United States)

    Haneburger, Ina; Fritz, Georg; Jurkschat, Nicole; Tetsch, Larissa; Eichinger, Andreas; Skerra, Arne; Gerland, Ulrich; Jung, Kirsten

    2012-11-23

    At acidic pH and in the presence of lysine, the pH sensor CadC activates transcription of the cadBA operon encoding the lysine/cadaverine antiporter CadB and the lysine decarboxylase CadA. In effect, these proteins contribute to acid stress adaptation in Escherichia coli. cadBA expression is feedback inhibited by cadaverine, and a cadaverine binding site is predicted within the central cavity of the periplasmic domain of CadC on the basis of its crystallographic analysis. Our present study demonstrates that this site only partially accounts for the cadaverine response in vivo. Instead, evidence for a second, pivotal binding site was collected, which overlaps with the pH-responsive patch of amino acids located at the dimer interface of the periplasmic domain. The temporal response of the E. coli Cad module upon acid shock was measured and modeled for two CadC variants with mutated cadaverine binding sites. These studies supported a cascade-like binding and deactivation model for the CadC dimer: binding of cadaverine within the pair of central cavities triggers a conformational transition that exposes two further binding sites at the dimer interface, and the occupation of those stabilizes the inactive conformation. Altogether, these data represent a striking example for the deactivation of a pH sensor. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Implementasi Penggunaan Aplikasi AutoCAD dalam Meningkatkan Kompetensi Dasar Menggambar teknik bagi Masyarakat

    Directory of Open Access Journals (Sweden)

    Risma Dwi Atmajayani

    2018-05-01

    Full Text Available Dengan berkembangnya teknologi, maka gambarpun ikut mengalami kemajuan dalam penggunaannya. Dengan kecanggihan dan kemajuan teknologi dapat melahirkan suatu cara menggambar dengan media komputer. Teknologi dapat membantu mempercepat menyelesaikan suatu pekerjaan, tidak terkecuali aplikasi CAD (Computer Aided Design. Program yang sering digunakan untuk pengajaran CAD adalah AutoCAD yang merupakan sebuah aplikasi (software yang digunakan untuk menggambar, mendesain gambar, menguji material dimana program tersebut mempunyai kemudahan dan keunggulan untuk membuat gambar secara tepat dan akurat. Berdasarkan temuan dilapangan yang didasari tinjauan langsung, didapatkan informasi bahwa materi AutoCAD yang diperoleh dari jenjang sebelumnya masih banyak yang jauh dari kondisi ideal. Materi AutoCAD yang didapatkan masih banyak tentang teori sedikit praktek, perangkat hardware yang terbatas sampai pada ketersediaan sumber daya manusia yang kurang adalah permasalahan umum yang terjadi. Adapun tujuan yang ingin dicapai adalah (1 Meningkatkan mutu peserta pelatihan melalui workshop pemanfaatan aplikasi AutoCAD (2 Meningkatkan ketrampilan peserta pelatihan dengan membuat suatu proyek desain gambar bangun berbasis aplikasi AutoCAD. Manfaat kegiatan pelatihan adalah: (1 Peserta pelatihan dapat meningkatkan pemahaman tentang program AutoCAD; (2 Peserta pelatihan dapat menyalurkan pengetahuan dan ketrampilan yang didapatkan nantinya kepada yang membutuhkan dan terutama akan sangat membantu para calon civil engineer dalam menyelesaikan pekerjaan yang berkaitan dengan desain rancang bangun; (3 Peserta pelatihan dapat mendesain gambar menggunakan program AutoCAD.

  12. Complete PCB design using OrCAD capture and layout

    CERN Document Server

    Mitzner, Kraig

    2011-01-01

    This book provides instruction on how to use the OrCAD design suite to design and manufacture printed circuit boards. The book is written for both students and practicing engineers who need a quick tutorial on how to use the software and who need in-depth knowledge of the capabilities and limitations of the software package. There are two goals the book aims to reach:The primary goal is to show the reader how to design a PCB using OrCAD Capture and OrCAD Layout. Capture is used to build the schematic diagram of the circuit, and Layout is used to design the circuit board so that

  13. Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network.

    Science.gov (United States)

    Albero, Alberto; Pascual, Agustín; Camps, Isabel; Grau-Benitez, María

    2015-10-01

    The field of dental ceramics for CAD-CAM is enriched with a new innovative material composition having a porous three-dimensional structure of feldspathic ceramic infiltrated with acrylic resins.The aim of this study is to determine the mechanical properties of Polymer-Infiltrated-Ceramic-Network (PICN) and compare its performance with other ceramics and a nano-ceramic resin available for CAD-CAM systems. In this study a total of five different materials for CAD-CAM were investigated. A polymer-infiltrated ceramic (Vita Enamic), a nano-ceramic resin (Lava Ultimate), a feldspathic ceramic (Mark II), a lithium disilicate ceramic (IPS-e max CAD) and finally a Leucite based ceramic (Empress - CAD). From CAD-CAM blocks, 120 bars (30 for each material cited above) were cut to measure the flexural strength with a three-point-bending test. Strain at failure, fracture stress and Weibull modulus was calculated. Vickers hardness of each material was also measured. IPS-EMAX presents mechanical properties significantly better from the other materials studied. Its strain at failure, flexural strength and hardness exhibited significantly higher values in comparison with the others. VITA ENAMIC and LAVA ULTIMATE stand out as the next most resistant materials. The flexural strength, elastic modulus similar to a tooth as well as having less hardness than ceramics make PICN materials an option to consider as a restorative material. Ceramic infiltrated with resin, CAD-CAM, Weibull modulus, flexural strength, micro hardness.

  14. Trends in CAD education in interior design programs

    OpenAIRE

    Ko, Hye Mi

    1990-01-01

    This research investigated Computer Aided Design (CAD) education in the interior design. program focusing on educators' opinions about creativity aspects including computer application, teaching materials and teaching methods as well as other trends in CAD education. A questionnaire was sent to one hundred eighty-two members of the Interior Design Educators Council (IDEC). A frequency distribution was used on 69 usable returned surveys to describe the sample characteristi...

  15. Ceramic dental biomaterials and CAD/CAM technology: state of the art.

    Science.gov (United States)

    Li, Raymond Wai Kim; Chow, Tak Wah; Matinlinna, Jukka Pekka

    2014-10-01

    Ceramics are widely used as indirect restorative materials in dentistry because of their high biocompatibility and pleasing aesthetics. The objective is to review the state of the arts of CAD/CAM all-ceramic biomaterials. CAD/CAM all-ceramic biomaterials are highlighted and a subsequent literature search was conducted for the relevant subjects using PubMed followed by manual search. Developments in CAD/CAM technology have catalyzed researches in all-ceramic biomaterials and their applications. Feldspathic glass ceramic and glass infiltrated ceramic can be fabricated by traditional laboratory methods or CAD/CAM. The advent of polycrystalline ceramics is a direct result of CAD/CAM technology without which the fabrication would not have been possible. The clinical uses of these ceramics have met with variable clinical success. Multiple options are now available to the clinicians for the fabrication of aesthetic all ceramic restorations. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  16. A new data integration approach for AutoCAD and GIS

    Science.gov (United States)

    Ye, Hongmei; Li, Yuhong; Wang, Cheng; Li, Lijun

    2006-10-01

    GIS has its advantages both on spatial data analysis and management, particularly on the geometric and attributive information management, which has also attracted lots attentions among researchers around world. AutoCAD plays more and more important roles as one of the main data sources of GIS. Various work and achievements can be found in the related literature. However, the conventional data integration from AutoCAD to GIS is time-consuming, which also can cause the information loss both in the geometric aspects and the attributive aspects for a large system. It is necessary and urgent to sort out new approach and algorithm for the efficient high-quality data integration. In this paper, a novel data integration approach from AutoCAD to GIS will be introduced based on the spatial data mining technique through the data structure analysis both in the AutoCAD and GIS. A practicable algorithm for the data conversion from CAD to GIS will be given as well. By a designed evaluation scheme, the accuracy of the conversion both in the geometric and the attributive information will be demonstrated. Finally, the validity and feasibility of the new approach will be shown by an experimental analysis.

  17. Optics learning by computing, with examples using Maple, MathCad, Mathematica, and MATLAB

    CERN Document Server

    Moeller, Karl Dieter

    2007-01-01

    This new edition is intended for a one semester course in optics for juniors and seniors in science and engineering; it uses scripts from Maple, MathCad, Mathematica, and MATLAB provide a simulated laboratory where students can learn by exploration and discovery instead of passive absorption. The text covers all the standard topics of a traditional optics course, including: geometrical optics and aberration, interference and diffraction, coherence, Maxwell's equations, wave guides and propagating modes, blackbody radiation, atomic emission and lasers, optical properties of materials, Fourier transforms and FT spectroscopy, image formation, and holography. It contains step by step derivations of all basic formulas in geometrical, wave and Fourier optics. The basic text is supplemented by over 170 files in Maple, MathCad, Mathematica, and MATLAB (many of which are in the text, each suggesting programs to solve a particular problem, and each linked to a topic in or application of optics. The computer files are d...

  18. [Application of microelectronics CAD tools to synthetic biology].

    Science.gov (United States)

    Madec, Morgan; Haiech, Jacques; Rosati, Élise; Rezgui, Abir; Gendrault, Yves; Lallement, Christophe

    2017-02-01

    Synthetic biology is an emerging science that aims to create new biological functions that do not exist in nature, based on the knowledge acquired in life science over the last century. Since the beginning of this century, several projects in synthetic biology have emerged. The complexity of the developed artificial bio-functions is relatively low so that empirical design methods could be used for the design process. Nevertheless, with the increasing complexity of biological circuits, this is no longer the case and a large number of computer aided design softwares have been developed in the past few years. These tools include languages for the behavioral description and the mathematical modelling of biological systems, simulators at different levels of abstraction, libraries of biological devices and circuit design automation algorithms. All of these tools already exist in other fields of engineering sciences, particularly in microelectronics. This is the approach that is put forward in this paper. © 2017 médecine/sciences – Inserm.

  19. CYBERSECURITY AND USER ACCOUNTABILITY IN THE C-AD CONTROL SYSTEM

    International Nuclear Information System (INIS)

    MORRIS, J.T.; BINELLO, S.; D OTTAVIO, T.; KATZ, R.A.

    2007-01-01

    A heightened awareness of cybersecurity has led to a review of the procedures that ensure user accountability for actions performed on the computers of the Collider-Accelerator Department (C-AD) Control System. Control system consoles are shared by multiple users in control rooms throughout the C-AD complex. A significant challenge has been the establishment of procedures that securely control and monitor access to these shared consoles without impeding accelerator operations. This paper provides an overview of C-AD cybersecurity strategies with an emphasis on recent enhancements in user authentication and tracking methods

  20. CYBERSECURITY AND USER ACCOUNTABILITY IN THE C-AD CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    MORRIS,J.T.; BINELLO, S.; D OTTAVIO, T.; KATZ, R.A.

    2007-10-15

    A heightened awareness of cybersecurity has led to a review of the procedures that ensure user accountability for actions performed on the computers of the Collider-Accelerator Department (C-AD) Control System. Control system consoles are shared by multiple users in control rooms throughout the C-AD complex. A significant challenge has been the establishment of procedures that securely control and monitor access to these shared consoles without impeding accelerator operations. This paper provides an overview of C-AD cybersecurity strategies with an emphasis on recent enhancements in user authentication and tracking methods.

  1. A tool for standardized collector performance calculations including PVT

    DEFF Research Database (Denmark)

    Perers, Bengt; Kovacs, Peter; Olsson, Marcus

    2012-01-01

    A tool for standardized calculation of solar collector performance has been developed in cooperation between SP Technical Research Institute of Sweden, DTU Denmark and SERC Dalarna University. The tool is designed to calculate the annual performance of solar collectors at representative locations...... can be tested and modeled as a thermal collector, when the PV electric part is active with an MPP tracker in operation. The thermal collector parameters from this operation mode are used for the PVT calculations....

  2. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  3. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  4. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  5. Development of CAD-Based Geometry Processing Module for a Monte Carlo Particle Transport Analysis Code

    International Nuclear Information System (INIS)

    Choi, Sung Hoon; Kwark, Min Su; Shim, Hyung Jin

    2012-01-01

    As The Monte Carlo (MC) particle transport analysis for a complex system such as research reactor, accelerator, and fusion facility may require accurate modeling of the complicated geometry. Its manual modeling by using the text interface of a MC code to define the geometrical objects is tedious, lengthy and error-prone. This problem can be overcome by taking advantage of modeling capability of the computer aided design (CAD) system. There have been two kinds of approaches to develop MC code systems utilizing the CAD data: the external format conversion and the CAD kernel imbedded MC simulation. The first approach includes several interfacing programs such as McCAD, MCAM, GEOMIT etc. which were developed to automatically convert the CAD data into the MCNP geometry input data. This approach makes the most of the existing MC codes without any modifications, but implies latent data inconsistency due to the difference of the geometry modeling system. In the second approach, a MC code utilizes the CAD data for the direct particle tracking or the conversion to an internal data structure of the constructive solid geometry (CSG) and/or boundary representation (B-rep) modeling with help of a CAD kernel. MCNP-BRL and OiNC have demonstrated their capabilities of the CAD-based MC simulations. Recently we have developed a CAD-based geometry processing module for the MC particle simulation by using the OpenCASCADE (OCC) library. In the developed module, CAD data can be used for the particle tracking through primitive CAD surfaces (hereafter the CAD-based tracking) or the internal conversion to the CSG data structure. In this paper, the performances of the text-based model, the CAD-based tracking, and the internal CSG conversion are compared by using an in-house MC code, McSIM, equipped with the developed CAD-based geometry processing module

  6. Marginal adaptation, fracture load and macroscopic failure mode of adhesively luted PMMA-based CAD/CAM inlays.

    Science.gov (United States)

    Ender, Andreas; Bienz, Stefan; Mörmann, Werner; Mehl, Albert; Attin, Thomas; Stawarczyk, Bogna

    2016-02-01

    To evaluate marginal adaptation, fracture load and failure types of CAD/CAM polymeric inlays. Standardized prepared human molars (48) were divided into four groups (n=12): (A) PCG (positive control group); adhesively luted glass-ceramic inlays, (B) TRX; CAD/CAM polymeric inlays luted using a self-adhesive resin cement, (C) TAC; CAD/CAM polymeric inlays luted using a conventional resin cement, and (D) NCG (negative control group); direct-filled resin-based composite restorations. All specimens were subjected to a chewing simulator. Before and after chewing fatigue, marginal adaptation was assessed at two interfaces: (1) between dental hard tissues and luting cement and (2) between luting cement and restoration. Thereafter, the specimens were loaded and the fracture loads, as well as the failure types, were determined. The data were analysed using three- and one-way ANOVA with post hoc Scheffé test, two sample Student's t-test (pmarginal adaptation for interface 1 showed significantly better results for TRX and PCG than for TAC (p=0.001-0.02) and NCG (p=0.001-0.047). For interface 2, marginal adaptation for TAC was significantly inferior to TRX (pmarginal adaptation of TAC and NCG. No significant differences in fracture load were found between all tested groups. Self-adhesive luted polymeric CAD/CAM inlays showed similar marginal adaptation and fracture load values compared to adhesively luted glass-ceramic inlays. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. Solid modeling and applications rapid prototyping, CAD and CAE theory

    CERN Document Server

    Um, Dugan

    2016-01-01

    The lessons in this fundamental text equip students with the theory of Computer Assisted Design (CAD), Computer Assisted Engineering (CAE), the essentials of Rapid Prototyping, as well as practical skills needed to apply this understanding in real world design and manufacturing settings. The book includes three main areas: CAD, CAE, and Rapid Prototyping, each enriched with numerous examples and exercises. In the CAD section, Professor Um outlines the basic concept of geometric modeling, Hermite and Bezier Spline curves theory, and 3-dimensional surface theories as well as rendering theory. The CAE section explores mesh generation theory, matrix notion for FEM, the stiffness method, and truss Equations. And in Rapid Prototyping, the author illustrates stereo lithographic theory and introduces popular modern RP technologies. Solid Modeling and Applications: Rapid Prototyping, CAD and CAE Theory is ideal for university students in various engineering disciplines as well as design engineers involved in product...

  8. Digital Dentistry — Digital Impression and CAD/CAM System Applications

    Directory of Open Access Journals (Sweden)

    Gabor Alin-Gabriel

    2017-03-01

    Full Text Available Digital imprint and computer-aided design/computer-aided manufacture (CAD/CAM systems offer several benefits compared to traditional techniques. The use of a CAD/CAM system to scan preparations and generate restorations in-office, removes a second appointment for the patient. The existence of precision benefits in using complete systems and chairside scanning systems, has been proven. CAD/CAM restorations have a good longevity and meet the accepted clinical parameters. New digital impression methods are presently accessible, and before long, the long-awaited goal of sparing patients of one the most unpleasant practices in clinical dentistry, acquiring dental impressions, will be exchanged by intraoral digital scanning. CAD/CAM systems existing nowadays, can feed data through accurate digital scans created from plaster models, straight to manufacturing systems that can shape ceramic or resin restorations with no requirement of a physical copy of the prepared, adjacent, and antagonist teeth.

  9. Flexural strength and microstructure of two lithium disilicate glass ceramics for CAD/CAM restoration in the dental clinic

    Directory of Open Access Journals (Sweden)

    Suk-Ho Kang

    2013-08-01

    Full Text Available Objectives There has been a growing interest in glass ceramic systems with good esthetics, high fracture resistance and bonding durability, and simplified fabrication techniques using CAD/CAM. The aim of this study is to compare flexural strength before and after heat treatment of two lithium disilicate CAD/CAM blocks, IPS e.max CAD (Ivoclar Vivadent and Rosetta SM (Hass, and to observe their crystalline structures. Materials and Methods Biaxial flexural strength was tested according to ISO 6872 with 20 disc form specimens sliced from each block before and after heat treatment. Also, the crystalline structures were observed using field-emission scanning microscopy (FE-SEM, Hitachi and x-ray diffraction (XRD, Rigaku analysis. The mean values of the biaxial flexural strength were analyzed by the Mann-Whitney U test at a significance level of p = 0.05. Results There were no statistically significant differences in flexural strength between IPS e.max CAD and Rosetta SM either before heat treatment or after heat treatment. For both ceramics, the initial flexural strength greatly increased after heat treatment, with significant differences (p < 0.05. The FE-SEM images presented similar patterns of crystalline structure in the two ceramics. In the XRD analysis, they also had similar patterns, presenting high peak positions corresponding to the standard lithium metasilicate and lithium disilicate at each stage of heat treatment. Conclusions IPS e.max CAD and Rosetta SM showed no significant differences in flexural strength. They had a similar crystalline pattern and molecular composition.

  10. CAD-RADS(TM) Coronary Artery Disease - Reporting and Data System. An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Radiology (ACR) and the North American Society for Cardiovascular Imaging (NASCI). Endorsed by the American College of Cardiology.

    Science.gov (United States)

    Cury, Ricardo C; Abbara, Suhny; Achenbach, Stephan; Agatston, Arthur; Berman, Daniel S; Budoff, Matthew J; Dill, Karin E; Jacobs, Jill E; Maroules, Christopher D; Rubin, Geoffrey D; Rybicki, Frank J; Schoepf, U Joseph; Shaw, Leslee J; Stillman, Arthur E; White, Charles S; Woodard, Pamela K; Leipsic, Jonathon A

    2016-01-01

    The intent of CAD-RADS - Coronary Artery Disease Reporting and Data System is to create a standardized method to communicate findings of coronary CT angiography (coronary CTA) in order to facilitate decision-making regarding further patient management. The suggested CAD-RADS classification is applied on a per-patient basis and represents the highest-grade coronary artery lesion documented by coronary CTA. It ranges from CAD-RADS 0 (Zero) for the complete absence of stenosis and plaque to CAD-RADS 5 for the presence of at least one totally occluded coronary artery and should always be interpreted in conjunction with the impression found in the report. Specific recommendations are provided for further management of patients with stable or acute chest pain based on the CAD-RADS classification. The main goal of CAD-RADS is to standardize reporting of coronary CTA results and to facilitate communication of test results to referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will provide a framework of standardization that may benefit education, research, peer-review and quality assurance with the potential to ultimately result in improved quality of care. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  11. Interstitial lung disease associated with collagen vascular disorders: disease quantification using a computer-aided diagnosis tool

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Dicken, V.; Kneitz, C.; Hoehmann, M.; Kenn, W.; Hahn, D.

    2009-01-01

    The purpose of this study was to evaluate a computer-aided diagnosis (CAD) tool compared to human observers in quantification of interstitial lung disease (ILD) in patients with collagen-vascular disorders. A total of 52 patients with rheumatoid arthritis (n=24), scleroderma (n=14) and systemic lupus erythematosus (n=14) underwent thin-section CT. Two independent observers assessed the extent of ILD (EoILD), reticulation (EoRet) and ground-glass opacity (EoGGO). CAD assessed EoILD twice. Pulmonary function tests were obtained. Statistical evaluation used 95% limits of agreement and linear regression analysis. CAD correlated well with diffusing capacity (DL CO ) (R=-0.531, P CO (R=-0.705, P CO and moderately with FVC (DL CO : R=-0.663; FVC: R=-0.436; P≤0.005). The CAD system is a promising tool for ILD quantification, showing close correlation with human observers and physiologic impairment. (orig.)

  12. Impact of a CAD system in a screen-film mammography screening program: A prospective study

    International Nuclear Information System (INIS)

    Sanchez Gómez, S.; Torres Tabanera, M.; Vega Bolivar, A.; Sainz Miranda, M.; Baroja Mazo, A.; Ruiz Diaz, M.; Martinez Miravete, P.; Lag Asturiano, E.; Muñoz Cacho, P.; Delgado Macias, T.

    2011-01-01

    Objective: The purpose of our study was to perform a prospective assessment of the impact of a CAD system in a screen-film mammography screening program during a period of 3 years. Materials and methods: Our study was carried out on a population of 21,855 asymptomatic women (45–65 years). Mammograms were processed in a CAD system and independently interpreted by one of six radiologists. We analyzed the following parameters: sensitivity of radiologist's interpretation (without and with CAD), detection increase, recall rate and positive predictive value of biopsy, CAD's marks, radiologist's false negatives and comparative analysis of carcinomas detected and non-detected by CAD. Results: Detection rate was 4.3‰. CAD supposed an increase of 0.1‰ in detection rate and 1% in the total number of cases (p < 0.005). The impact on recall rate was not significant (0.4%) and PPV of percutaneous biopsy was unchanged by CAD (20.23%). CAD's marks were 2.7 per case and 0.7 per view. Radiologist's false negatives were 13 lesions which were initially considered as CAD's false positives. Conclusions: CAD supposed a significant increase in detection, without modifications in recall rates and PPV of biopsy. However, better results could have been achieved if radiologists had considered actionable those cases marked by CAD but initially misinterpreted.

  13. RSP Tooling Technology

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-11-20

    RSP Tooling{trademark} is a spray forming technology tailored for producing molds and dies. The approach combines rapid solidification processing and net-shape materials processing in a single step. The general concept involves converting a mold design described by a CAD file to a tooling master using a suitable rapid prototyping (RP) technology such as stereolithography. A pattern transfer is made to a castable ceramic, typically alumina or fused silica (Figure 1). This is followed by spray forming a thick deposit of a tooling alloy on the pattern to capture the desired shape, surface texture, and detail. The resultant metal block is cooled to room temperature and separated from the pattern. The deposit's exterior walls are machined square, allowing it to be used as an insert in a standard mold base. The overall turnaround time for tooling is about 3 to 5 days, starting with a master. Molds and dies produced in this way have been used in high volume production runs in plastic injection molding and die casting. A Cooperative Research and Development Agreement (CRADA) between the Idaho National Engineering and Environmental Laboratory (INEEL) and Grupo Vitro has been established to evaluate the feasibility of using RSP Tooling technology for producing molds and dies of interest to Vitro. This report summarizes results from Phase I of this agreement, and describes work scope and budget for Phase I1 activities. The main objective in Phase I was to demonstrate the feasibility of applying the Rapid Solidification Process (RSP) Tooling method to produce molds for the manufacture of glass and other components of interest to Vitro. This objective was successfully achieved.

  14. Utilização do AutoCAD 2004 para quantificação de pesquisas usando fotomicrografias eletrônicas AutoCAD 2004 to quantify electron-photomicrography

    Directory of Open Access Journals (Sweden)

    Carla Albertina Martins Almeida

    2007-08-01

    Full Text Available OBJETIVO: Avaliar o uso do programa AutoCAD 2004 para estudos quantitativos em microscopia eletrônica. MÉTODOS: A demonstração da utilização do AutoCAD 2004 foi feita em um modelo experimental de diabetes induzido em ratos, divididos em Grupo Controle (GC-10 animais e Grupo Diabético (GD - 10 animais, avaliados 1 mês depois da indução do diabetes. Os olhos foram removidos após o sacrifício dos animais e preparados para exame em microscópio eletrônico, tendo sido feitas fotografias dos vasos retinianos. Foi utilizado o programa AutoCAD2004 para avaliar a espessura da membrana basal dos vasos. Os resultados foram avaliados estatisticamente. RESULTADOS: Usando o método proposto foi possível realizar medidas quantitativas na membrana basal de vasos retinianos de ratos diabéticos. CONCLUSÃO: O AutoCAD 2004 se mostrou efetivo, seguro e de fácil utilização para a quantificação de fenômenos biológicos, sendo possível sugerir este meio para a realização de avaliações quantitativas em experimentos biológicos.OBJECTIVE: To determine if the AutoCAD 2004 program is available to be used in quantitative research on electron microscopy. METHODS: A demonstrative of the AutoCAD2004 was done in an experimental model of diabetes induced in rats. The animals were divided by lot in control group animals (GC-10 animals and diabetic group (GD - 10 animals, evaluated 1 month after the diabetes induction. The eyes were removed after sacrifice and prepared to electron microscopy. The retina was photographed and the AutoCAD2004 program was used to measure the basal membrane of retina vessels. The results were submitted to statistical analysis. RESULTS: The AutoCAD2004 was effective to obtain quantitative measures from the basal membrane of retina vessels and there were no difference between the studied groups. CONCLUSION: The AutoCAD2004 was effective, safe and easy to apply to quantify biological parameters, which allowed suggest it to

  15. A Virtual CAD Model of the LHC

    CERN Document Server

    Chemli, S; Messerli, R; Muttoni, Y; Prin, H; Van Uytvinck, E

    2000-01-01

    Integrating the large and complex LHC machine into the existing LEP tunnel is a major challenge. Space was not really a problem to fit the LEP machine into its tunnel, but LHC cryostats are much larger than the LEP quadrupoles and the external cryogenic line fills even more the tunnel. Space problems lead to small clearances. Possible conflicts, or at least the most penalising ones, between installed equipment or with transport, must be solved beforehand in order to avoid unacceptable delays and extra costs during the installation. Experience gained with LEP has already shown the help that Computer-Aided Engineering tools could provide for the integration. A virtual model of the LHC is presently prepared. The actual LEP tunnel, known with a quite good accuracy (centimetre level), has been modelled and all the elements of the machine constructed as 3D objects with the CAD system are positioned accurately on the basis of data generated from the theoretical definition. These layouts are used to generate the refe...

  16. DsixTools: the standard model effective field theory toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Celis, Alejandro [Ludwig-Maximilians-Universitaet Muenchen, Fakultaet fuer Physik, Arnold Sommerfeld Center for Theoretical Physics, Munich (Germany); Fuentes-Martin, Javier; Vicente, Avelino [Universitat de Valencia-CSIC, Instituto de Fisica Corpuscular, Valencia (Spain); Virto, Javier [University of Bern, Albert Einstein Center for Fundamental Physics, Institute for Theoretical Physics, Bern (Switzerland)

    2017-06-15

    We present DsixTools, a Mathematica package for the handling of the dimension-six standard model effective field theory. Among other features, DsixTools allows the user to perform the full one-loop renormalization group evolution of the Wilson coefficients in the Warsaw basis. This is achieved thanks to the SMEFTrunner module, which implements the full one-loop anomalous dimension matrix previously derived in the literature. In addition, DsixTools also contains modules devoted to the matching to the ΔB = ΔS = 1, 2 and ΔB = ΔC = 1 operators of the Weak Effective Theory at the electroweak scale, and their QCD and QED Renormalization group evolution below the electroweak scale. (orig.)

  17. A visual LISP program for voxelizing AutoCAD solid models

    Science.gov (United States)

    Marschallinger, Robert; Jandrisevits, Carmen; Zobl, Fritz

    2015-01-01

    AutoCAD solid models are increasingly recognized in geological and geotechnical 3D modeling. In order to bridge the currently existing gap between AutoCAD solid models and the grid modeling realm, a Visual LISP program is presented that converts AutoCAD solid models into voxel arrays. Acad2Vox voxelizer works on a 3D-model that is made up of arbitrary non-overlapping 3D-solids. After definition of the target voxel array geometry, 3D-solids are scanned at grid positions and properties are streamed to an ASCII output file. Acad2Vox has a novel voxelization strategy that combines a hierarchical reduction of sampling dimensionality with an innovative use of AutoCAD-specific methods for a fast and memory-saving operation. Acad2Vox provides georeferenced, voxelized analogs of 3D design data that can act as regions-of-interest in later geostatistical modeling and simulation. The Supplement includes sample geological solid models with instructions for practical work with Acad2Vox.

  18. Accuracy Assessment of Immediate and Delayed Implant Placements Using CAD/CAM Surgical Guides.

    Science.gov (United States)

    Alzoubi, Fawaz; Massoomi, Nima; Nattestad, Anders

    2016-10-01

    The aim of this study is to assess the accuracy of immediately placed implants using Anatomage Invivo5 computer-assisted design/computer-assisted manufacturing (CAD/CAM) surgical guides and compare the accuracy to delayed implant placement protocol. Patients who had implants placed using Anatomage Invivo5 CAD/CAM surgical guides during the period of 2012-2015 were evaluated retrospectively. Patients who received immediate implant placements and/or delayed implant placements replacing 1-2 teeth were included in this study. Pre- and postsurgical images were superimposed to evaluate deviations at the crest, apex, and angle. A total of 40 implants placed in 29 patients were included in this study. The overall mean deviations measured at the crest, apex, and angle were 0.86 mm, 1.25 mm, and 3.79°, respectively. The means for the immediate group deviations were: crest = 0.85 mm, apex = 1.10, and angle = 3.49°. The means for the delayed group deviations were: crest = 0.88 mm, apex = 1.59, and angle = 4.29°. No statistically significant difference was found at the crest and angle; however, there was a statistically significant difference between the immediate and delayed group at the apex, with the immediate group presenting more accurate placements at the apical point than the delayed group. CAD/CAM surgical guides can be reliable tools to accurately place implants immediately and/or in a delayed fashion. No statistically significant differences were found between the delayed and the immediate group at the crest and angle, however apical position was more accurate in the immediate group.

  19. Repairability of CAD/CAM high-density PMMA- and composite-based polymers.

    Science.gov (United States)

    Wiegand, Annette; Stucki, Lukas; Hoffmann, Robin; Attin, Thomas; Stawarczyk, Bogna

    2015-11-01

    The study aimed to analyse the shear bond strength of computer-aided design and computer-aided manufacturing (CAD/CAM) polymethyl methacrylate (PMMA)- and composite-based polymer materials repaired with a conventional methacrylate-based composite after different surface pretreatments. Each 48 specimens was prepared from six different CAD/CAM polymer materials (Ambarino high-class, artBloc Temp, CAD-Temp, Lava Ultimate, Telio CAD, Everest C-Temp) and a conventional dimethacrylate-based composite (Filtek Supreme XTE, control) and aged by thermal cycling (5000 cycles, 5-55 °C). The surfaces were left untreated or were pretreated by mechanical roughening, aluminium oxide air abrasion or silica coating/silanization (each subgroup n = 12). The surfaces were further conditioned with an etch&rinse adhesive (OptiBond FL) before the repair composite (Filtek Supreme XTE) was adhered to the surface. After further thermal cycling, shear bond strength was tested, and failure modes were assessed. Shear bond strength was statistically analysed by two- and one-way ANOVAs and Weibull statistics, failure mode by chi(2) test (p ≤ 0.05). Shear bond strength was highest for silica coating/silanization > aluminium oxide air abrasion = mechanical roughening > no surface pretreatment. Independently of the repair pretreatment, highest bond strength values were observed in the control group and for the composite-based Everest C-Temp and Ambarino high-class, while PMMA-based materials (artBloc Temp, CAD-Temp and Telio CAD) presented significantly lowest values. For all materials, repair without any surface pretreatment resulted in adhesive failures only, which mostly were reduced when surface pretreatment was performed. Repair of CAD/CAM high-density polymers requires surface pretreatment prior to adhesive and composite application. However, four out of six of the tested CAD/CAM materials did not achieve the repair bond strength of a conventional dimethacrylate

  20. Bonding to new CAD/CAM resin composites: influence of air abrasion and conditioning agents as pretreatment strategy.

    Science.gov (United States)

    Reymus, Marcel; Roos, Malgorzata; Eichberger, Marlis; Edelhoff, Daniel; Hickel, Reinhard; Stawarczyk, Bogna

    2018-04-27

    Because of their industrially standardized process of manufacturing, CAD/CAM resin composites show a high degree of conversion, making a reliable bond difficult to achieve. The purpose of this experiment was to investigate the tensile bond strength (TBS) of luting composite to CAD/CAM resin composite materials as influenced by air abrasion and pretreatment strategies. The treatment factors of the present study were (1) brand of the CAD/CAM resin composite (Brilliant Crios [Coltene/Whaledent], Cerasmart [GC Europe], Shofu Block HC [Shofu], and Lava Ultimate [3M]); (2) air abrasion vs. no air abrasion; and (3) pretreatment using a silane primer (Clearfil Ceramic Primer, Kuraray) vs. a resin primer (One Coat 7 Universal, Coltene/Whaledent). Subsequently, luting composite (DuoCem, Coltene/Whaledent) was polymerized onto the substrate surface using a mold. For each combination of the levels of the three treatment factors (4 (materials) × 2 (air abrasion vs. no air abrasion; resin) × 2 (primer vs. silane primer)), n = 15, specimens were prepared. After 24 h of water storage at 37 °C and 5000 thermo-cycles (5/55 °C), TBS was measured and failure types were examined. The resulting data was analyzed using Kaplan-Meier estimates of the cumulative failure distribution function with Breslow-Gehan tests and non-parametric ANOVA (Kruskal-Wallis test) followed by the multiple pairwise Mann-Whitney U test with α-error adjustment using the Benjamini-Hochberg procedure and chi-square test (p CAD/CAM resin composites, the restorations should be air abraded and pretreated using a resin primer containing methyl-methacrylate to successfully bond to the luting composite. The pretreatment of the CAD/CAM resin composite using merely a silane primer results in deficient adhesion. For a reliable bond of CAD/CAM resin composites to the luting composite, air abrasion and a special pretreatment strategy are necessary in order to achieve promising long-term results.

  1. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.

    Science.gov (United States)

    Papadiochou, Sofia; Pissiotis, Argirios L

    2018-04-01

    The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy

  2. Lung nodule detection on chest CT: evaluation of a computer-aided detection (CAD) system

    International Nuclear Information System (INIS)

    Lee, In Jae; Gamsu, Gordon; Czum, Julianna; Johnson, Rebecca; Chakrapani, Sanjay; Wu, Ning

    2005-01-01

    To evaluate the capacity of a computer-aided detection (CAD) system to detect lung nodules in clinical chest CT. A total of 210 consecutive clinical chest CT scans and their reports were reviewed by two chest radiologists and 70 were selected (33 without nodules and 37 with 1-6 nodules, 4-15.4 mm in diameter). The CAD system (ImageChecker CT LN-1000) developed by R2 Technology, Inc. (Sunnyvale, CA) was used. Its algorithm was designed to detect nodules with a diameter of 4-20 mm. The two chest radiologists working with the CAD system detected a total of 78 nodules. These 78 nodules form the database for this study. Four independent observers interpreted the studies with and without the CAD system. The detection rates of the four independent observers without CAD were 81% (63/78), 85% (66/78), 83% (65/78), and 83% (65/78), respectively. With CAD their rates were 87% (68/78), 85% (66/78), 86% (67/78), and 85% (66/78), respectively. The differences between these two sets of detection rates did not reach statistical significance. In addition, CAD detected eight nodules that were not mentioned in the original clinical radiology reports. The CAD system produced 1.56 false-positive nodules per CT study. The four test observers had 0, 0.1, 0.17, and 0.26 false-positive results per study without CAD and 0.07, 0.2, 0.23, and 0.39 with CAD, respectively. The CAD system can assist radiologists in detecting pulmonary nodules in chest CT, but with a potential increase in their false positive rates. Technological improvements to the system could increase the sensitivity and specificity for the detection of pulmonary nodules and reduce these false-positive results

  3. Comparative study of electromagnetic compatibility methods in printed circuit board design tools

    International Nuclear Information System (INIS)

    Marinova, Galia

    2002-01-01

    The paper considers the state-of-the art in electromagnetic compatibility (EMC) oriented printed circuit board (PCB) design. A general methodology of EMC oriented PCB design is synthesized. The main CAD tools available today are estimated and compared for their abilities to treat EMC oriented design. To help non experts a knowledge-base containing more than 50 basic rules for EMC-oriented PCB design is proposed. It can be applied in the PCB design CAD tools that possess rule-builders or it can help interactive design. Trends in this area of EMC-oriented PCB design are deduced. (Author)

  4. Mechanical properties and internal fit of 4 CAD-CAM block materials.

    Science.gov (United States)

    Goujat, Alexis; Abouelleil, Hazem; Colon, Pierre; Jeannin, Christophe; Pradelle, Nelly; Seux, Dominique; Grosgogeat, Brigitte

    2018-03-01

    .69 GPa (IPS e.max CAD). The mean fracture toughness ranged from 1.2 ±0.17 MPa.m 1/2 (Cerasmart) to 1.8 ±0.29 MPa.m 1/2 (IPS e.max CAD). The values for internal discrepancy ranged from 119 ±55 μm to 234 ±51 μm. The mean internal discrepancy was significantly higher for Lava Ultimate (PCAD and Cerasmart but not for Vita Enamic. The factor ''material'' was statistically significant in relation to the mechanical properties evaluated in this study (PCAD-CAM block materials tested were within the acceptable range for fabrication of single restorations according to the ISO standard for ceramics (ISO 6872:2008). IPS e.max CAD and Cerasmart were observed to have superior flexural strength and better internal fit. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Introduction of effect and consideration of the introduction of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-12-01

    This reports introduction of effect and consideration of the introduction of computer-aided design and computer aided manufacturing system. It includes outline of CAD/CAM system like definition, classification, system kinds, and development process of CAD/CAM system, technology, market trend development prospect, and value on introduction of this system, and current application of CAD/CAM system in major application area, development countries and Korea.

  6. 7. Prevalence of CAD in asymptomatic type II diabetics, using MPI as screening tool. Single center cross sectional study from KSA

    Directory of Open Access Journals (Sweden)

    Anwar Jelani

    2017-10-01

    Conclusion: Despite higher rate of diabetes in Saudi Arabia, asymptomatic Diabetics have a lower than expected incidence of active CAD. There would be a need to test this notion further. This would require more studies to confirm our findings in Saudi population.

  7. Dental students' preferences and performance in crown design: conventional wax-added versus CAD.

    Science.gov (United States)

    Douglas, R Duane; Hopp, Christa D; Augustin, Marcus A

    2014-12-01

    The purpose of this study was to evaluate dental students' perceptions of traditional waxing vs. computer-aided crown design and to determine the effectiveness of either technique through comparative grading of the final products. On one of twoidentical tooth preparations, second-year students at one dental school fabricated a wax pattern for a full contour crown; on the second tooth preparation, the same students designed and fabricated an all-ceramic crown using computer-aided design (CAD) and computer-aided manufacturing (CAM) technology. Projects were graded for occlusion and anatomic form by three faculty members. On completion of the projects, 100 percent of the students (n=50) completed an eight-question, five-point Likert scalesurvey, designed to assess their perceptions of and learning associated with the two design techniques. The average grades for the crown design projects were 78.3 (CAD) and 79.1 (wax design). The mean numbers of occlusal contacts were 3.8 (CAD) and 2.9(wax design), which was significantly higher for CAD (p=0.02). The survey results indicated that students enjoyed designing afull contour crown using CAD as compared to using conventional wax techniques and spent less time designing the crown using CAD. From a learning perspective, students felt that they learned more about position and the size/strength of occlusal contacts using CAD. However, students recognized that CAD technology has limits in terms of representing anatomic contours and excursive occlusion compared to conventional wax techniques. The results suggest that crown design using CAD could be considered as an adjunct to conventional wax-added techniques in preclinical fixed prosthodontic curricula.

  8. Discoloration of various CAD/CAM blocks after immersion in coffee

    Directory of Open Access Journals (Sweden)

    Sasipin Lauvahutanon

    2017-02-01

    Full Text Available Objectives This study evaluated color differences (ΔEs and translucency parameter changes (ΔTPs of various computer-aided design/computer-aided manufacturing (CAD/CAM blocks after immersion in coffee. Materials and Methods Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L*a*b* values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6. The ΔEs and ΔTPs of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05. The ΔEs after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results After one month in coffee, ΔEs of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ΔTPs decreased. The ANOVA of ΔEs and ΔTPs revealed significant differences in two main factors, immersion periods and media, and their interaction except for ΔEs of TEL (Telio CAD, Ivoclar Vivadent. The ΔEs significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC. There was no significant correlation between ΔEs and water sorption or solubility in water. Conclusions The ΔEs of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

  9. CAD-RADS™: Coronary Artery Disease - Reporting and Data System: An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Radiology (ACR) and the North American Society for Cardiovascular Imaging (NASCI). Endorsed by the American College of Cardiology.

    Science.gov (United States)

    Cury, Ricardo C; Abbara, Suhny; Achenbach, Stephan; Agatston, Arthur; Berman, Daniel S; Budoff, Matthew J; Dill, Karin E; Jacobs, Jill E; Maroules, Christopher D; Rubin, Geoffrey D; Rybicki, Frank J; Schoepf, U Joseph; Shaw, Leslee J; Stillman, Arthur E; White, Charles S; Woodard, Pamela K; Leipsic, Jonathon A

    2016-12-01

    The intent of CAD-RADS - Coronary Artery Disease Reporting and Data System is to create a standardized method to communicate findings of coronary CT angiography (coronary CTA) in order to facilitate decision-making regarding further patient management. The suggested CAD-RADS classification is applied on a per-patient basis and represents the highest-grade coronary artery lesion documented by coronary CTA. It ranges from CAD-RADS 0 (Zero) for the complete absence of stenosis and plaque to CAD-RADS 5 for the presence of at least one totally occluded coronary artery and should always be interpreted in conjunction with the impression found in the report. Specific recommendations are provided for further management of patients with stable or acute chest pain based on the CAD-RADS classification. The main goal of CAD-RADS is to standardize reporting of coronary CTA results and to facilitate communication of test results to referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will provide a framework of standardization that may benefit education, research, peer-review and quality assurance with the potential to ultimately result in improved quality of care. Copyright © 2016 Society of Cardiovascular Computed Tomography and the American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Accuracy of CAD-CAM-fabricated removable partial dentures.

    Science.gov (United States)

    Arnold, Christin; Hey, Jeremias; Schweyen, Ramona; Setz, Jürgen M

    2018-04-01

    The conventional fabrication of removable partial dentures (RPDs) is a complex, error-prone, time-consuming, and expensive process. The use of computer-aided design and computer-aided manufacturing (CAD-CAM) techniques, especially rapid prototyping, promises a more effective method for fabricating RPD frameworks. The purpose of this in vitro study was to evaluate the fit of RPD clasps fabricated by means of 4 different CAD-CAM-systems and to compare those fittings with that of the conventional lost-wax casting technique (LWT). A master model of a partially edentulous maxilla with the canines and second molars as the remaining teeth was fabricated. After the model was optically scanned, we designed a quadrangularly supported RPD with 4 clasps and a palatal strap major connector. A standard tessellation language data set was used to fabricate 12 identical RPDs by using 4 different CAD-CAM techniques: indirect rapid prototyping (wax inject printing combined with LWT), direct rapid prototyping (selective laser melting), indirect milling (wax milling with LWT), and direct milling (resin milling [polyetheretherketone]). Three conventionally cast RPDs (LWT) served as the control group. The fit accuracy of the clasps (n=12 for each group) was determined in both the horizontal and vertical dimensions by using light microscopy. Indirectly milled RPDs (117 ±34 μm horizontal and 45 ±21 μm vertical) and directly milled RPDs (43 ±23 μm horizontal, and 38 ±21 μm vertical) showed significantly better (P<.05) fit than did conventionally fabricated LWT RPDs (133 ±59 μm horizontal; 73 ±25 μm vertical). The worst fit was found for RPDs fabricated using indirect rapid prototyping (323 ±188 μm horizontal and 112 ±60 μm vertical) or direct rapid prototyping (365 ±205 μm horizontal and 363 ±133 μm vertical), which were unstable on the master model, making them unsuitable for clinical use. Most RPDs exhibited smaller vertical measuring distances. Compared with the LWT

  11. Complete PCB design using OrCAD capture and PCB editor

    CERN Document Server

    Mitzner, Kraig

    2009-01-01

    This book provides instruction on how to use the OrCAD design suite to design and manufacture printed circuit boards. The primary goal is to show the reader how to design a PCB using OrCAD Capture and OrCAD Editor. Capture is used to build the schematic diagram of the circuit, and Editor is used to design the circuit board so that it can be manufactured. The book is written for both students and practicing engineers who need in-depth instruction on how to use the software, and who need background knowledge of the PCB design process. KEY FEATURES:* Beginning to end cove

  12. A wheat cinnamyl alcohol dehydrogenase TaCAD12 contributes to host resistance to the sharp eyespot disease

    Directory of Open Access Journals (Sweden)

    Wei Rong

    2016-11-01

    Full Text Available Sharp eyespot, caused mainly by the necrotrophic fungus Rhizoctonia cerealis, is a destructive disease in hexaploid wheat (Triticum aestivum L.. In Arabidopsis, certain cinnamyl alcohol dehydrogenases (CADs have been implicated in monolignol biosynthesis and in defense response to bacterial pathogen infection. However, little is known about CADs in wheat defense responses to necrotrophic or soil-borne pathogens. In this study, we isolate a wheat CAD gene TaCAD12 in response to R. cerealis infection through microarray-based comparative transcriptomics, and study the enzyme activity and defense role of TaCAD12 in wheat. The transcriptional levels of TaCAD12 in sharp eyespot-resistant wheat lines were significantly higher compared with those in susceptible wheat lines. The sequence and phylogenetic analyses revealed that TaCAD12 belongs to IV group in CAD family. The biochemical assay proved that TaCAD12 protein is an authentic CAD enzyme and possesses catalytic efficiencies towards both coniferyl aldehyde and sinapyl aldehyde. Knock-down of TaCAD12 transcript significantly repressed resistance of the gene-silenced wheat plants to sharp eyespot caused by R. cerealis, whereas TaCAD12 overexpression markedly enhanced resistance of the transgenic wheat lines to sharp eyespot. Furthermore, certain defense genes (Defensin, PR10, PR17c, and Chitinase1 and monolignol biosynthesis-related genes (TaCAD1, TaCCR, and TaCOMT1 were up-regulated in the TaCAD12-overexpressing wheat plants but down-regulated in TaCAD12-silencing plants. These results suggest that TaCAD12 positively contributes to resistance against sharp eyespot through regulation of the expression of certain defense genes and monolignol biosynthesis-related genes in wheat.

  13. Structure, functional characterization, and evolution of the dihydroorotase domain of human CAD.

    Science.gov (United States)

    Grande-García, Araceli; Lallous, Nada; Díaz-Tejada, Celsa; Ramón-Maiques, Santiago

    2014-02-04

    Upregulation of CAD, the multifunctional protein that initiates and controls the de novo biosynthesis of pyrimidines in animals, is essential for cell proliferation. Deciphering the architecture and functioning of CAD is of interest for its potential usage as an antitumoral target. However, there is no detailed structural information about CAD other than that it self-assembles into hexamers of ∼1.5 MDa. Here we report the crystal structure and functional characterization of the dihydroorotase domain of human CAD. Contradicting all assumptions, the structure reveals an active site enclosed by a flexible loop with two Zn²⁺ ions bridged by a carboxylated lysine and a third Zn coordinating a rare histidinate ion. Site-directed mutagenesis and functional assays prove the involvement of the Zn and flexible loop in catalysis. Comparison with homologous bacterial enzymes supports a reclassification of the DHOase family and provides strong evidence against current models of the architecture of CAD. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations.

    Science.gov (United States)

    Quaas, Sebastian; Rudolph, Heike; Luthardt, Ralph G

    2007-12-01

    The basic prerequisite for the production of dental restorations by means of CAD/CAM technologies is the data acquisition (digitization). Currently, two methods are available, i.e. the extraoral digitization of master casts and the direct intraoral data acquisition. However, it seems to be beneficial to immediately digitize impressions directly at the dental office in order to combine the high precision of mechanical digitizing methods and to shorten the production process. The aim of this study was to investigate the measurement uncertainty (+/-2sigma) and the three-dimensional accuracy of the immediate tactile in-office digitization of dental impressions and of the mechanical digitizing of ceramic master dies using a high-precision touch-probe digitizer. The experimental set-up consisted of ceramic master dies representing tooth 13 and 36 as well as their identical virtual models (CAD models). Fifteen one-step putty-wash impressions were taken from each tooth. The impressions as well as the ceramic master dies were digitized applying a standardized procedure. The datasets were aligned to the corresponding CAD models; then, a computer-aided three-dimensional analysis was performed. The digitizing of the dental impressions showed a measurement uncertainty of 5.8, mean positive deviations between 27 and 28microm, and mean negative deviations between -21 and -31microm. The digitizing of the ceramic master dies showed a measurement uncertainty of 2.8, mean positive deviations between 7.7 and 9.1microm, and mean negative deviations between -8.5 and -8.8microm. Mechanical digitizers show a very low measurement uncertainty and a high precision. The immediate tactile in-office digitization of impressions cannot be recommended as adequate data acquisition method for CAD/CAM restorations. It is recommendable to digitize clinical sites extraorally, i.e. after taking an impression and fabricating a model cast thereof.

  15. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  16. CAD/CAM-assisted breast reconstruction

    International Nuclear Information System (INIS)

    Melchels, Ferry; Hutmacher, Dietmar Werner; Wiggenhauser, Paul Severin; Schantz, Jan-Thorsten; Warne, David; Barry, Mark; Ong, Fook Rhu; Chong, Woon Shin

    2011-01-01

    The application of computer-aided design and manufacturing (CAD/CAM) techniques in the clinic is growing slowly but steadily. The ability to build patient-specific models based on medical imaging data offers major potential. In this work we report on the feasibility of employing laser scanning with CAD/CAM techniques to aid in breast reconstruction. A patient was imaged with laser scanning, an economical and facile method for creating an accurate digital representation of the breasts and surrounding tissues. The obtained model was used to fabricate a customized mould that was employed as an intra-operative aid for the surgeon performing autologous tissue reconstruction of the breast removed due to cancer. Furthermore, a solid breast model was derived from the imaged data and digitally processed for the fabrication of customized scaffolds for breast tissue engineering. To this end, a novel generic algorithm for creating porosity within a solid model was developed, using a finite element model as intermediate.

  17. Rapid proto typing of dental prosthesis by means of a feldspathic glass composite mixed with muscovite mica via CAD/CAM

    International Nuclear Information System (INIS)

    Garcia Junior, E.S.; Gomes Junior, G.G.; Fonseca, M.D.; Moraes, E.E.S.; Ogasawara, T.

    2010-01-01

    The work consists in the use and integration of CAD/CAM tools as a process of design and manufacture of a rapid prototyping of dental prosthesis by machining using a CNC milling machine. The material machined to obtain the dental prosthesis were cylindrical blocks of a Feldspathic glass composite mixed with muscovite mica in various percentages (15%, 40% and 80%), which was resigned under biaxial pressing and sintered in vacuum at temperatures from 800 to 1100 deg C. The composite was characterized by XRD and SEM. The results show that increasing the crystallization of leucite is consequent to the temperature increase, and that the use of CAD/CAM system using a CNC milling machine is feasible to obtain dental prosthesis. (author)

  18. When and why might a Computer Aided Detection (CAD) system interfere with visual search? An eye-tracking study

    Science.gov (United States)

    Drew, Trafton; Cunningham, Corbin; Wolfe, Jeremy

    2012-01-01

    Rational and Objectives Computer Aided Detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. Methods 47 naïve observers in two studies were asked to search for a target, embedded in 1/f2.4 noise while we monitored their eye-movements. For some observers, a CAD system marked 75% of targets and 10% of distractors while other observers completed the study without CAD. In Experiment 1, the CAD system’s primary function was to tell observers where the target might be. In Experiment 2, CAD provided information about target identity. Results In Experiment 1, there was a significant enhancement of observer sensitivity in the presence of CAD (t(22)=4.74, pCAD system were missed more frequently than equivalent targets in No CAD blocks of the experiment (t(22)=7.02, pCAD, but also no significant cost on sensitivity to unmarked targets (t(22)=0.6, p=n.s.). Finally, in both experiments, CAD produced reliable changes in eye-movements: CAD observers examined a lower total percentage of the search area than the No CAD observers (Ex 1: t(48)=3.05, pCAD signals do not combine with observers’ unaided performance in a straight-forward manner. CAD can engender a sense of certainty that can lead to incomplete search and elevated chances of missing unmarked stimuli. PMID:22958720

  19. Usefulness of the CAD System for Detecting Pulmonary Nodule in Real Clinical Practice

    International Nuclear Information System (INIS)

    Song, Kyoung Doo; Chung, Myung Jin; Kim, Hee Cheol; Lee, Kyung Soo; Jeong, Sun Young

    2011-01-01

    We wanted to evaluate the usefulness of the computer-aided detection (CAD) system for detecting pulmonary nodules in real clinical practice by using the CT images. Our Institutional Review Board approved our retrospective study with a waiver of informed consent. This study included 166 CT examinations that were performed for the evaluation of pulmonary metastasis in 166 patients with colorectal cancer. All the CT examinations were interpreted by radiologists and they were also evaluated by the CAD system. All the nodules detected by the CAD system were evaluated with regard to whether or not they were true nodules, and they were classified into micro nodules (MN, diameter < 4 mm) and significant nodules (SN, 4 ≤ diameter ≤ 10 mm). The radiologic reports and CAD results were compared. The CAD system helped detect 426 nodules: 115 (27%) of the 426 nodules were classified as true nodules and 35 (30%) of the 115 nodules were SNs, and 83 (72%) of the 115 were not mentioned in the radiologists' reports and three (4%) of the 83 nodules were non-calcified SNs. One of three non-calcified SNs was confirmed as a metastatic nodule. According to the radiologists' reports, 60 true nodules were detected, and 28 of the 60 were not detected by the CAD system. Although the CAD system missed many SNs that are detected by radiologists, it helps detect additional nodules that are missed by the radiologists in real clinical practice. Therefore, the CAD system can be useful to support a radiologist's detection performance

  20. The Nucleotide Synthesis Enzyme CAD Inhibits NOD2 Antibacterial Function in Human Intestinal Epithelial Cells

    Science.gov (United States)

    Richmond, Amy L.; Kabi, Amrita; Homer, Craig R.; García, Noemí Marina; Nickerson, Kourtney P.; NesvizhskiI, Alexey I.; Sreekumar, Arun; Chinnaiyan, Arul M.; Nuñez, Gabriel; McDonald, Christine

    2013-01-01

    BACKGROUND & AIMS Polymorphisms that reduce the function of nucleotide-binding oligomerization domain (NOD)2, a bacterial sensor, have been associated with Crohn’s disease (CD). No proteins that regulate NOD2 activity have been identified as selective pharmacologic targets. We sought to discover regulators of NOD2 that might be pharmacologic targets for CD therapies. METHODS Carbamoyl phosphate synthetase/ aspartate transcarbamylase/dihydroorotase (CAD) is an enzyme required for de novo pyrimidine nucleotide synthesis; it was identified as a NOD2-interacting protein by immunoprecipitation-coupled mass spectrometry. CAD expression was assessed in colon tissues from individuals with and without inflammatory bowel disease by immunohistochemistry. The interaction between CAD and NOD2 was assessed in human HCT116 intestinal epithelial cells by immunoprecipitation, immunoblot, reporter gene, and gentamicin protection assays. We also analyzed human cell lines that express variants of NOD2 and the effects of RNA interference, overexpression and CAD inhibitors. RESULTS CAD was identified as a NOD2-interacting protein expressed at increased levels in the intestinal epithelium of patients with CD compared with controls. Overexpression of CAD inhibited NOD2-dependent activation of nuclear factor κB and p38 mitogen-activated protein kinase, as well as intracellular killing of Salmonella. Reduction of CAD expression or administration of CAD inhibitors increased NOD2-dependent signaling and antibacterial functions of NOD2 variants that are and are not associated with CD. CONCLUSIONS The nucleotide synthesis enzyme CAD is a negative regulator of NOD2. The antibacterial function of NOD2 variants that have been associated with CD increased in response to pharmacologic inhibition of CAD. CAD is a potential therapeutic target for CD. PMID:22387394

  1. Bone Reduction to Facilitate Immediate Implant Placement and Loading Using CAD/CAM Surgical Guides for Patients With Terminal Dentition.

    Science.gov (United States)

    Alzoubi, Fawaz; Massoomi, Nima; Nattestad, Anders

    2016-10-01

    The aim of this study is to present a method, using 3 computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, to accurately obtain the desired bone reduction followed by immediate implant placements and loading for patients diagnosed with terminal dentition. Patients who had bone reduction, implants placed, and immediate loading using Anatomage Invivo 5 CAD/CAM surgical guides between the period 2013 and 2015 were evaluated retrospectively. Patients diagnosed with terminal dentition and treated using the "3-guide technique" were identified. Pre- and postsurgical images were superimposed to evaluate deviations of the bone reduction and deviations at the crest, apex, and angle of implants placed. Twenty-six implants placed in 5 patients were included in this study. The overall deviation means measured for bone reduction was 1.98 mm. The overall deviation means measured for implant placement at the crest, apex, and angle were 1.43 mm, 1.90 mm, and 4.14°, respectively. The CAD/CAM surgical guide fabrication is an emerging tool that may facilitate the surgical process and aid in safe and predictable execution of bone reduction and immediate implant placement. Using 3 CAD/CAM surgical guides, a method is presented to obtain the desired bone reduction followed by immediate implant placement and loading for patients diagnosed with terminal dentition. This method may improve guide stability for patients with terminal dentition undergoing complete implant-supported treatment by taking advantage of the teeth to be extracted.

  2. Numerical Analysis of Turbulent Flow around Tube Bundle by Applying CAD Best Practice Guideline

    International Nuclear Information System (INIS)

    Lee, Gong Hee; Bang, Young Seok; Woo, Sweng Woong; Cheng, Ae Ju

    2013-01-01

    In this study, the numerical analysis of a turbulent flow around both a staggered and an incline tube bundle was conducted using Annoys Cfx V. 13, a commercial CAD software. The flow was assumed to be steady, incompressible, and isothermal. According to the CAD Best Practice Guideline, the sensitivity study for grid size, accuracy of the discretization scheme for convection term, and turbulence model was conducted, and its result was compared with the experimental data to estimate the applicability of the CAD Best Practice Guideline. It was concluded that the CAD Best Practice Guideline did not always guarantee an improvement in the prediction performance of the commercial CAD software in the field of tube bundle flow

  3. MEASURING INFORMATION INTEGR-ATION MODEL FOR CAD/CMM

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A CAD/CMM workpiece modeling system based on IGES file is proposed. The modeling system is implemented by using a new method for labelling the tolerance items of 3D workpiece. The concept-"feature face" is used in the method. First the CAD data of workpiece are extracted and recognized automatically. Then a workpiece model is generated, which is the integration of pure 3D geometry form with its corresponding inspection items. The principle of workpiece modeling is also presented. At last, the experiment results are shown and correctness of the model is certified.

  4. Microcomputer Simulated CAD for Engineering Graphics.

    Science.gov (United States)

    Huggins, David L.; Myers, Roy E.

    1983-01-01

    Describes a simulated computer-aided-graphics (CAD) program at The Pennsylvania State University. Rationale for the program, facilities, microcomputer equipment (Apple) used, and development of a software package for simulating applied engineering graphics are considered. (JN)

  5. The Use of Pro/Engineer CAD Software and Fishbowl Tool Kit in Ray-tracing Analysis

    Science.gov (United States)

    Nounu, Hatem N.; Kim, Myung-Hee Y.; Ponomarev, Artem L.; Cucinotta, Francis A.

    2009-01-01

    This document is designed as a manual for a user who wants to operate the Pro/ENGINEER (ProE) Wildfire 3.0 with the NASA Space Radiation Program's (SRP) custom-designed Toolkit, called 'Fishbowl', for the ray tracing of complex spacecraft geometries given by a ProE CAD model. The analysis of spacecraft geometry through ray tracing is a vital part in the calculation of health risks from space radiation. Space radiation poses severe risks of cancer, degenerative diseases and acute radiation sickness during long-term exploration missions, and shielding optimization is an important component in the application of radiation risk models. Ray tracing is a technique in which 3-dimensional (3D) vehicle geometry can be represented as the input for the space radiation transport code and subsequent risk calculations. In ray tracing a certain number of rays (on the order of 1000) are used to calculate the equivalent thickness, say of aluminum, of the spacecraft geometry seen at a point of interest called the dose point. The rays originate at the dose point and terminate at a homogenously distributed set of points lying on a sphere that circumscribes the spacecraft and that has its center at the dose point. The distance a ray traverses in each material is converted to aluminum or other user-selected equivalent thickness. Then all equivalent thicknesses are summed up for each ray. Since each ray points to a direction, the aluminum equivalent of each ray represents the shielding that the geometry provides to the dose point from that particular direction. This manual will first list for the user the contact information for help in installing ProE and Fishbowl in addition to notes on the platform support and system requirements information. Second, the document will show the user how to use the software to ray trace a Pro/E-designed 3-D assembly and will serve later as a reference for troubleshooting. The user is assumed to have previous knowledge of ProE and CAD modeling.

  6. Comparative assessment of different approaches for the use of CAD geometry in Monte Carlo transport calculations

    International Nuclear Information System (INIS)

    Weinhorst, Bastian; Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng; Wilson, Paul

    2015-01-01

    Highlights: • Comparison of different approaches for the use of CAD geometry for Monte Carlo transport calculations. • Comparison with regard to user-friendliness and computation performance. • Three approaches, namely conversion with McCad, unstructured mesh feature of MCN6 and DAGMC. • Installation most complex for DAGMC, model preparation worst for McCad, computation performance worst for MCNP6. • Installation easiest for McCad, model preparation best for MCNP6, computation speed fastest for McCad. - Abstract: Computer aided design (CAD) is an important industrial way to produce high quality designs. Therefore, CAD geometries are in general used for engineering and the design of complex facilities like the ITER tokamak. Although Monte Carlo codes like MCNP are well suited to handle the complex 3D geometry of ITER for transport calculations, they rely on their own geometry description and are in general not able to directly use the CAD geometry. In this paper, three different approaches for the use of CAD geometries with MCNP calculations are investigated and assessed with regard to calculation performance and user-friendliness. The first method is the conversion of the CAD geometry into MCNP geometry employing the conversion software McCad developed by KIT. The second approach utilizes the MCNP6 mesh geometry feature for the particle tracking and relies on the conversion of the CAD geometry into a mesh model. The third method employs DAGMC, developed by the University of Wisconsin-Madison, for the direct particle tracking on the CAD geometry using a patched version of MCNP. The obtained results show that each method has its advantages depending on the complexity and size of the model, the calculation problem considered, and the expertise of the user.

  7. Comparative assessment of different approaches for the use of CAD geometry in Monte Carlo transport calculations

    Energy Technology Data Exchange (ETDEWEB)

    Weinhorst, Bastian, E-mail: bastian.weinhorst@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Eggenstein-Leopoldshafen (Germany); Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Eggenstein-Leopoldshafen (Germany); Wilson, Paul [University of Wisconsin-Madison, Computational Nuclear Engineering Research Group, Madison, WI (United States)

    2015-10-15

    Highlights: • Comparison of different approaches for the use of CAD geometry for Monte Carlo transport calculations. • Comparison with regard to user-friendliness and computation performance. • Three approaches, namely conversion with McCad, unstructured mesh feature of MCN6 and DAGMC. • Installation most complex for DAGMC, model preparation worst for McCad, computation performance worst for MCNP6. • Installation easiest for McCad, model preparation best for MCNP6, computation speed fastest for McCad. - Abstract: Computer aided design (CAD) is an important industrial way to produce high quality designs. Therefore, CAD geometries are in general used for engineering and the design of complex facilities like the ITER tokamak. Although Monte Carlo codes like MCNP are well suited to handle the complex 3D geometry of ITER for transport calculations, they rely on their own geometry description and are in general not able to directly use the CAD geometry. In this paper, three different approaches for the use of CAD geometries with MCNP calculations are investigated and assessed with regard to calculation performance and user-friendliness. The first method is the conversion of the CAD geometry into MCNP geometry employing the conversion software McCad developed by KIT. The second approach utilizes the MCNP6 mesh geometry feature for the particle tracking and relies on the conversion of the CAD geometry into a mesh model. The third method employs DAGMC, developed by the University of Wisconsin-Madison, for the direct particle tracking on the CAD geometry using a patched version of MCNP. The obtained results show that each method has its advantages depending on the complexity and size of the model, the calculation problem considered, and the expertise of the user.

  8. Development and Validation of a Standardized Tool for Prioritization of Information Sources.

    Science.gov (United States)

    Akwar, Holy; Kloeze, Harold; Mukhi, Shamir

    2016-01-01

    To validate the utility and effectiveness of a standardized tool for prioritization of information sources for early detection of diseases. The tool was developed with input from diverse public health experts garnered through survey. Ten raters used the tool to evaluate ten information sources and reliability among raters was computed. The Proc mixed procedure with random effect statement and SAS Macros were used to compute multiple raters' Fleiss Kappa agreement and Kendall's Coefficient of Concordance. Ten disparate information sources evaluated obtained the following composite scores: ProMed 91%; WAHID 90%; Eurosurv 87%; MediSys 85%; SciDaily 84%; EurekAl 83%; CSHB 78%; GermTrax 75%; Google 74%; and CBC 70%. A Fleiss Kappa agreement of 50.7% was obtained for ten information sources and 72.5% for a sub-set of five sources rated, which is substantial agreement validating the utility and effectiveness of the tool. This study validated the utility and effectiveness of a standardized criteria tool developed to prioritize information sources. The new tool was used to identify five information sources suited for use by the KIWI system in the CEZD-IIR project to improve surveillance of infectious diseases. The tool can be generalized to situations when prioritization of numerous information sources is necessary.

  9. Computer Aided Design Tools for Extreme Environment Electronics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project aims to provide Computer Aided Design (CAD) tools for radiation-tolerant, wide-temperature-range digital, analog, mixed-signal, and radio-frequency...

  10. Is the application of CAD useful for radiologists for passing the official tests required for outpatient breast imaging?

    International Nuclear Information System (INIS)

    Malich, A.; Beier, A.; Gorna, R.; Bank, P.

    2007-01-01

    Purpose: to analyze whether currently available CAD systems meet the diagnostic requirements for passing screening tests (first reader CAD) and to analyze whether the additional usage of CAD systems provides significant support for the diagnosing radiologist on the basis of official screening test cases (second reading by CAD). Material and methods: 200 images of 100 mammographies of 50 patients of an official screening test case collection were analyzed double-blind with and without CAD printouts (iCAD, U.S.A.) by three radiologists: one experienced in breast analysis and CAD application, one experienced in mammography analysis but inexperienced in CAD usage, one with minimal experience with breast analysis and CAD application. All radiologists measured the largest diameter of any malignant mass. The mean value of these calculations was correlated to the largest diameter given by CAD prompts. Results: the mean sensitivity and specificity increased slightly as a result of the additional usage of CAD (1 and 0.6%, resp.). Both values are not statistically significant. The highest effect was measured for the radiologist with CAD experience, while no effect was measured for the inexperienced radiologist. CAD met the sensitivity requirements but not the specificity criteria (96 and 20.3%, resp.). The sizes given by CAD prompts corresponded significantly with the real sizes (r = 0.45, p < 0.05). (orig.)

  11. Introduction to AutoCAD 2013 2D and 3D design

    CERN Document Server

    Yarwood, Alf

    2013-01-01

    Master the complexities of the world's bestselling 2D and 3D software with Alf Yarwood's Introduction to AutoCAD 2013. Ideally suited to new users of AutoCAD, this book will be a useful resource for drawing modules in both vocational and introductory undergraduate courses in engineering and construction.Alf Yarwood has once again produced a comprehensive, step-by-step introduction to the latest release of AutoCAD. Covering all the basic principles and acting as an introduction to 2D drawing, it also contains extensive coverage of all 3D topics, including 3D solid modelling a

  12. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    Science.gov (United States)

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  13. Progress of conversion system from CAD data to MCNP geometry data in Japan

    International Nuclear Information System (INIS)

    Sato, S.; Nashif, H.; Masuda, F.; Morota, H.; Iida, H.; Konno, C.

    2010-01-01

    Automatic conversion systems from CAD data to MCNP geometry input data have been developed to convert the CAD data of the fusion reactor with very complicated structure. So far, two conversion systems (GEOMIT-1 and ARCMCP) have been developed and the third system (GEOMIT-2) is under developing. The void data can be created in these systems. GEOMIT-1 was developed in 2007, but a lot of manual shape splitting work for the CAD data was required to convert the complicated geometry. ARCMCP was developed in 2008. The algorithm has been drastically improved on automatic creation of ambiguous surface in ARCMCP, but it still required a little manual shape splitting work. The latest system, GEOMIT-2, does not require additional commercial software packages, though the previous systems require them. It also has functions of the CAD data healing and the automatic shape splitting. Geometrical errors of CAD data can be automatically revised by the healing function, and complicated geometries can be automatically split into simple geometries by the shape splitting function. Any manual works for CAD data are not required in GEOMIT-2. GEOMIT-2 is very useful for nuclear analyses of fusion reactors.

  14. Data format standard for sharing light source measurements

    Science.gov (United States)

    Gregory, G. Groot; Ashdown, Ian; Brandenburg, Willi; Chabaud, Dominique; Dross, Oliver; Gangadhara, Sanjay; Garcia, Kevin; Gauvin, Michael; Hansen, Dirk; Haraguchi, Kei; Hasna, Günther; Jiao, Jianzhong; Kelley, Ryan; Koshel, John; Muschaweck, Julius

    2013-09-01

    Optical design requires accurate characterization of light sources for computer aided design (CAD) software. Various methods have been used to model sources, from accurate physical models to measurement of light output. It has become common practice for designers to include measured source data for design simulations. Typically, a measured source will contain rays which sample the output distribution of the source. The ray data must then be exported to various formats suitable for import into optical analysis or design software. Source manufacturers are also making measurements of their products and supplying CAD models along with ray data sets for designers. The increasing availability of data has been beneficial to the design community but has caused a large expansion in storage needs for the source manufacturers since each software program uses a unique format to describe the source distribution. In 2012, the Illuminating Engineering Society (IES) formed a working group to understand the data requirements for ray data and recommend a standard file format. The working group included representatives from software companies supplying the analysis and design tools, source measurement companies providing metrology, source manufacturers creating the data and users from the design community. Within one year the working group proposed a file format which was recently approved by the IES for publication as TM-25. This paper will discuss the process used to define the proposed format, highlight some of the significant decisions leading to the format and list the data to be included in the first version of the standard.

  15. Two-body wear rate of CAD/CAM resin blocks and their enamel antagonists.

    Science.gov (United States)

    Stawarczyk, Bogna; Özcan, Mutlu; Trottmann, Albert; Schmutz, Felix; Roos, Malgorzata; Hämmerle, Christoph

    2013-05-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) resins exhibit good mechanical properties and can be used as long-term restorations. The wear rate of such resins and their enamel antagonists is unknown. The purpose of this study was to test and compare the 2-body wear rate of CAD/CAM resin blocks. Wear specimens (N=42, n=6) were made from 5 CAD/CAM resins: ZENO PMMA (ZP), artBloc Temp (AT), Telio CAD (TC), Blanc High-class (HC), CAD-Temp (CT); 1 manually polymerized resin: Integral esthetic press (negative control group, IEP); and 1 glass-ceramic: VITA Mark II (positive control group, VM2). The specimens for the wear resistance were aged in a thermomechanical loading machine (49 N, 1.67 Hz, 5/50°C) with human enamel antagonists. The material loss of all specimens before, during, and after aging was evaluated with a 3DS profilometer. The measured material loss data of all tested groups were statistically evaluated with linear mixed model analysis (a=.05). Manually polymerized resin showed significantly higher material wear (P<.001) than all other tested groups. Glass-ceramic showed significantly lower wear values (P<.001) than CAD/CAM resins ZP, AT, HC, CT, and IES. CAD/CAM resin TC was not significantly different from the positive control group. Glass-ceramic showed the highest enamel wear values (P<.001) of all tested resins. No differences were found in the enamel wear among all resins. The glass-ceramic group showed damage in the form of cracks on the worn enamel surface in 50% of specimens. CAD/CAM resins showed lower wear rates than those conventionally polymerized. Only one CAD/CAM resin, TC, presented material wear values comparable with glass-ceramic. The tested glass-ceramic developed cracks in the enamel antagonist and showed the highest enamel wear values of all other tested groups. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  16. LEARNING TOOLS INTEROPERABILITY – A NEW STANDARD FOR INTEGRATION OF DISTANCE LEARNING PLATFORMS

    Directory of Open Access Journals (Sweden)

    Oleksandr A. Shcherbyna

    2015-06-01

    Full Text Available For information technology in education there is always an issue of re-usage of electronic educational resources, their transferring possibility from one virtual learning environment to another. Previously, standardized sets of files were used to serve this purpose, for example, SCORM-packages. In this article the new standard Learning Tools Interoperability (LTI is reviewed, which allows users from one environment to access resources from another environment. This makes it possible to integrate them into a single distributed learning environment that is created and shared. The article gives examples of the practical use of standard LTI in Moodle learning management system using External tool and LTI provider plugins.

  17. A Step-by-Step Conservative Approach for CAD-CAM Laminate Veneers

    Directory of Open Access Journals (Sweden)

    Gerardo Durán Ojeda

    2017-01-01

    Full Text Available The use of CAD/CAM technology has allowed the fabrication of ceramic restorations efficiently and with predictable results. Lithium disilicate is a type of glass ceramic material that can be used for the elaboration of laminate veneers, being monolithic restorations which require characterization through a covering ceramic in order to achieve acceptable esthetic results. The next case report shows a predictable clinical protocol for the rehabilitation of the anterior teeth through the preparation of CAD/CAM veneers (e.max CAD, Ivoclar Vivadent, Liechtenstein which have been characterized by a nanofluorapatite ceramic (e.max Ceram, Ivoclar Vivadent, Liechtenstein through the layering technique.

  18. Marginal and internal fit of nano-composite CAD/CAM restorations

    Directory of Open Access Journals (Sweden)

    So-Hyun Park

    2016-02-01

    Full Text Available Objectives The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods A full veneer crown and an mesio-occluso-distal (MOD inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU and experimental nano-composite CAD/CAM blocks (EB under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000. In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001. Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000. Conclusions The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

  19. Edge strength of CAD/CAM materials.

    Science.gov (United States)

    Pfeilschifter, Maria; Preis, Verena; Behr, Michael; Rosentritt, Martin

    2018-05-16

    To investigate the edge force of CAD/CAM materials as a function of (a) material, (b) thickness, and (c) distance from the margin. Materials intended for processing with CAD/CAM were investigated: eight resin composites, one resin-infiltrated ceramic, and a clinically proven lithiumdisilicate ceramic (reference). To measure edge force (that is, load to failure/crack), plates (d = 1 mm) were fixed and loaded with a Vickers diamond indenter (1 mm/min, Zwick 1446) at a distance of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm from the edge. Edge force was defined as a loading force at a distance of 0.5 mm. The type of failure was determined. To investigate the influence of the thickness, all data were determined on 1-mm and 2-mm plates. To test the influence of bonding and an underlying dentin, individual 1-mm plates were bonded to a 1-mm-thick dentin-like (concerning modulus of elasticity) resin composite. For the 1-mm plates, edge force varied between 64.4 ± 24.2 N (Shofu Block HC) and 183.2 ± 63.3 N (ceramic reference), with significant (p ≤ 0.001) differences between the materials. For the 2-mm plates, values between 129.2 ± 32.5 N (Lava Ultimate) and 230.3 ± 67.5 N (Cerasmart) were found. Statistical comparison revealed no significant differences (p > 0.109) between the materials. Brilliant Crios (p = 0.023), Enamic (p = 0.000), Shofu Blocks HC (p = 0.009), and Grandio Bloc (p = 0.002) showed significantly different edge force between the 1-mm- and 2-mm-thick plates. The failure pattern was either cracking, (severe) chipping, or fracture. Material, material thickness, and distance from the edge impact the edge force of CAD/CAM materials. CAD/CAM materials should be carefully selected on the basis of their individual edge force and performance during milling. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. AsBuilt-image with photogrammetry and 3D-CAD

    International Nuclear Information System (INIS)

    Kamsties, K.D.

    1993-01-01

    Using the combined method of photogrammetry and 3D-CAD, one obtains an AsBuilt-model of a plant, e.g. of a nuclear power plant, which surpasses all conventional methods of documentation concerning graphic quality as well as the possibilities of evaluation by data processing. With the 3D-CAD-model a full representation of the plant e.g. for safety assessment (''On-screen inspection'') or as a basis for future re-planning is available in the office. (orig./DG) [de

  1. Job Grading Standard for Machine Tool Operator, WG-3431.

    Science.gov (United States)

    Civil Service Commission, Washington, DC. Bureau of Policies and Standards.

    The standard covers nonsupervisory work involved in the set up, adjustment, and operation of conventional machine tools to perform machining operations in the manufacture and repair of castings, forgings, or parts from raw stock made of various metals, metal alloys, and other materials. A general description of the job at both the WG-8 and WG-9…

  2. CT Colonography: Role of a second reader CAD paradigm in the initial training of radiologists

    International Nuclear Information System (INIS)

    Neri, Emanuele; Faggioni, Lorenzo; Regge, Daniele; Vagli, Paola; Turini, Francesca; Cerri, Francesca; Picano, Eugenia; Giusti, Sabina; Bartolozzi, Carlo

    2011-01-01

    Purpose: To evaluate the influence of CAD for the evaluation of CT colonography (CTC) datasets by inexperienced readers during the attendance of a dedicated hands-on training course. Method and materials: Twenty-seven radiologists inexperienced in CTC (11 with no CTC training at all, 16 having previously reviewed no more than 10 CTC cases overall) attended a hands-on training course based on direct teaching on fifteen workstations (four Advantage Windows 4.4 with Colon VCAR software, GE; six CADCOLON, Im3D; five ColonScreen (Toshiba/Voxar) with ColonCAD TM API, Medicsight). During the course, readers were instructed to analyze 26 CTC cases including 38 colonic lesions obtained through low-dose MDCT acquisitions, consisting of 12 polyps sized less than 6 mm, 9 polyps sized between 6 and 10 mm, 12 polyps sized between 11 mm and 30 mm, and 5 colonic masses sized >3 cm. CTC images were reviewed by each reader both in 2D and 3D mode, respectively by direct evaluation of native axial images and MPR reconstructions, and virtual endoscopy or dissected views. Each reader had 15 min time for assessing each dataset without CAD, after which results were compared with those provided by CAD software. Global rater sensitivity for each lesion size before and after CAD usage was compared by means of two-tailed Student's t test, while sensitivity of each single reader before and after CAD usage was assessed with the McNemar test. Results: For lesions sized 30 mm, sensitivity before CAD-assisted reading was 0.3556 ± 0.3105 and did not change after CAD usage (p = 1). Sensitivity of each single rater did not significantly differ before and after CAD for any lesion size category (McNemar test, p > 0.05). Specificity was not significantly different before and after CAD for any lesion size (>96% for all size categories). Conclusion: CAD usage led to increased overall sensitivity of inexperienced readers for all polyps sizes, except for lesions >30 mm, but sensitivity of individual raters

  3. Effect of Home Bleaching on the Translucency of CAD/CAM Systems.

    Science.gov (United States)

    Karci, Muhammet; Demir, Necla

    2017-11-10

    To evaluate the effect of a home bleaching agent (Opalescence PF) on the translucency of CAD/CAM ceramic systems. The 28 sintered ceramic specimens (IPS Empress CAD and IPS e.max CAD; 15 mm long, 10 mm wide, 1 mm thick) were divided into two subgroups as control and bleaching groups (n = 7). Carbamide peroxide (CP), 16%, home bleaching agent was applied onto the surface of each specimen for 6 hours per day for 7 days. A spectrophotometer (VITA Easyshade Advance) was used to measure the CIE L * a * b * coordinates and the reflectance value (Y) of the specimens on white and black backgrounds. The translucency parameter (TP), contrast ratio (CR), and opalescence parameter (OP) of the specimens were calculated. The data were statistically analyzed using Kolmogorov-Smirnov, one-way ANOVA, Tukey's test, and Pearson's correlation. Statistically significant differences in the TP values after 16% CP bleaching treatment were observed (p ˂ 0.05); however, no significant differences were found in the OP and CR values after the surface treatment (p ˃ 0.05). According to our study, patients who have all-ceramic restorations in their mouths should be careful when using home bleaching agents, because whitening agents can affect the translucency of all-ceramic restorations such as e.max CAD and Empress CAD. © 2017 by the American College of Prosthodontists.

  4. Frequency of coronary artery disease (cad) risk factors in armed forces

    International Nuclear Information System (INIS)

    Kamran, S.M.; Iftikhar, R.; Abbasi, K.

    2015-01-01

    To determine the frequency of risk factors of coronary artery disease (CAD) in apparently healthy soldiers of Pakistan Armed Forces. Study Design: Cross sectional descriptive study. Place and Duration of Study: Department of medicine, CMH Okara from July 2012 to Dec 2012. Patients and Methods: The study included 2215 male currently serving soldiers in age range of 18 to 52 years by consecutive sampling. Relevant history, body mass index (BMI), waist circumference (WC) and blood pressure (BP) of each subject were recorded. BMI > 25 kg/m/sup 2/ and WC > 90 cm was considered obesity and abdominal obesity respectively. BP > 140/90 mmHg was defined as hypertension. All the participants of study underwent blood glucose fasting, blood glucose random, ECG recording, personality assessment and lipid profile. Risk estimation was done using Eric Brittain scoring system. Results: In our study group 95.5% patients were having at least 1 risk factor of CAD, 54 % were having 2 to 4 risk factors while 3.93% had > 4 risk factors. Risk estimation of CAD using Eric Brittain scoring system showed that a large proportion of study group had high probability of developing ischemic heart disease in next 6 years. Conclusion: A large proportion of our soldiers are harboring risk of CAD due to increase in frequency of 8 conventional CAD risk factors especially obesity. (author)

  5. The Z-cad dual fluorescent sensor detects dynamic changes between the epithelial and mesenchymal cellular states.

    Science.gov (United States)

    Toneff, M J; Sreekumar, A; Tinnirello, A; Hollander, P Den; Habib, S; Li, S; Ellis, M J; Xin, L; Mani, S A; Rosen, J M

    2016-06-17

    The epithelial to mesenchymal transition (EMT) has been implicated in metastasis and therapy resistance of carcinomas and can endow cancer cells with cancer stem cell (CSC) properties. The ability to detect cancer cells that are undergoing or have completed EMT has typically relied on the expression of cell surface antigens that correlate with an EMT/CSC phenotype. Alternatively these cells may be permanently marked through Cre-mediated recombination or through immunostaining of fixed cells. The EMT process is dynamic, and these existing methods cannot reveal such changes within live cells. The development of fluorescent sensors that mirror the dynamic EMT state by following the expression of bona fide EMT regulators in live cells would provide a valuable new tool for characterizing EMT. In addition, these sensors will allow direct observation of cellular plasticity with respect to the epithelial/mesenchymal state to enable more effective studies of EMT in cancer and development. We generated a lentiviral-based, dual fluorescent reporter system, designated as the Z-cad dual sensor, comprising destabilized green fluorescent protein containing the ZEB1 3' UTR and red fluorescent protein driven by the E-cadherin (CDH1) promoter. Using this sensor, we robustly detected EMT and mesenchymal to epithelial transition (MET) in breast cancer cells by flow cytometry and fluorescence microscopy. Importantly, we observed dynamic changes in cellular populations undergoing MET. Additionally, we used the Z-cad sensor to identify and isolate minor subpopulations of cells displaying mesenchymal properties within a population comprising predominately epithelial-like cells. The Z-cad dual sensor identified cells with CSC-like properties more effectively than either the ZEB1 3' UTR or E-cadherin sensor alone. The Z-cad dual sensor effectively reports the activities of two factors critical in determining the epithelial/mesenchymal state of carcinoma cells. The ability of this stably

  6. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening

    DEFF Research Database (Denmark)

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR......) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were...... excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences...

  7. Analysis of HOM Problems in the C-ADS Main Linac

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Burn [Chinese Academy of Sciences (CAS), Lanzhou (China). Inst. of Modern Physics; Ng, King Yuen [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2017-05-18

    Excitation of higher-order modes (HOMs) in superconducting cavities may severely affect the operation of the main linac in the Chinese Accelerator Driven System (CADS). Preliminary analysis is made on the effects of beam dynamic, which includes possible longitudinal and transverse emittance enlargements, as well as the possibility of beam breakup. Suggestions are given for further investigation. Comparison is made between the C-ADS and the Fermilab Project X.

  8. Chairside CAD/CAM materials. Part 3: Cyclic fatigue parameters and lifetime predictions.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Valladares, Diana; Petschelt, Anselm; Lohbauer, Ulrich

    2018-06-01

    Chemical and mechanical degradation play a key role on the lifetime of dental restorative materials. Therefore, prediction of their long-term performance in the oral environment should base on fatigue, rather than inert strength data, as commonly observed in the dental material's field. The objective of the present study was to provide mechanistic fatigue parameters of current dental CAD/CAM materials under cyclic biaxial flexure and assess their suitability in predicting clinical fracture behaviors. Eight CAD/CAM materials, including polycrystalline zirconia (IPS e.max ZirCAD), reinforced glasses (Vitablocs Mark II, IPS Empress CAD), glass-ceramics (IPS e.max CAD, Suprinity PC, Celtra Duo), as well as hybrid materials (Enamic, Lava Ultimate) were evaluated. Rectangular plates (12×12×1.2mm 3 ) with highly polished surfaces were prepared and tested in biaxial cyclic fatigue in water until fracture using the Ball-on-Three-Balls (B3B) test. Cyclic fatigue parameters n and A* were obtained from the lifetime data for each material and further used to build SPT diagrams. The latter were used to compare in-vitro with in-vivo fracture distributions for IPS e.max CAD and IPS Empress CAD. Susceptibility to subcritical crack growth under cyclic loading was observed for all materials, being more severe (n≤20) in lithium-based glass-ceramics and Vitablocs Mark II. Strength degradations of 40% up to 60% were predicted after only 1 year of service. Threshold stress intensity factors (K th ) representing the onset of subcritical crack growth (SCG), were estimated to lie in the range of 0.37-0.44 of K Ic for the lithium-based glass-ceramics and Vitablocs Mark II and between 0.51-0.59 of K Ic for the other materials. Failure distributions associated with mechanistic estimations of strength degradation in-vitro showed to be useful in interpreting failure behavior in-vivo. The parameter K th stood out as a better predictor of clinical performance in detriment to the SCG n

  9. Structural Insight into the Core of CAD, the Multifunctional Protein Leading De Novo Pyrimidine Biosynthesis.

    Science.gov (United States)

    Moreno-Morcillo, María; Grande-García, Araceli; Ruiz-Ramos, Alba; Del Caño-Ochoa, Francisco; Boskovic, Jasminka; Ramón-Maiques, Santiago

    2017-06-06

    CAD, the multifunctional protein initiating and controlling de novo biosynthesis of pyrimidines in animals, self-assembles into ∼1.5 MDa hexamers. The structures of the dihydroorotase (DHO) and aspartate transcarbamoylase (ATC) domains of human CAD have been previously determined, but we lack information on how these domains associate and interact with the rest of CAD forming a multienzymatic unit. Here, we prove that a construct covering human DHO and ATC oligomerizes as a dimer of trimers and that this arrangement is conserved in CAD-like from fungi, which holds an inactive DHO-like domain. The crystal structures of the ATC trimer and DHO-like dimer from the fungus Chaetomium thermophilum confirm the similarity with the human CAD homologs. These results demonstrate that, despite being inactive, the fungal DHO-like domain has a conserved structural function. We propose a model that sets the DHO and ATC complex as the central element in the architecture of CAD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    International Nuclear Information System (INIS)

    Destounis, S.; Hanson, S.

    2007-01-01

    This study was conducted to retrospectively evaluate a computer-aided detection system's ability to detect breast carcinoma in multiple standard mammographic projections. Forty-five lesions in 44 patients imaged with digital mammography (Selenia registered , Hologic, Bedford, MA; Senographe registered , GE, Milwaukee, WI) and had computer-aided detection (CAD, Image-checker registered V 8.3.15, Hologic/R2, Santa Clara, CA) applied at the time of examination were identified for review; all were subsequently recommended to biopsy where cancer was revealed. These lesions were determined by the study Radiologist to be visible in both standard mammographic images (mediolateral oblique, MLO; craniocaudal, CC). For each patient, case data included patient age, tissue density, lesion type, BIRADS registered assessment, lesion size, lesion visibility-visible on MLO and/or CC view, ability of CAD to correctly mark the cancerous lesion, number of CAD marks per image, needle core biopsy results and surgical pathologic correlation. For this study cohort. CAD lesion/case sensitivity of 87% (n = 39) was found and image sensitivity was found to be 69% (n = 31) for MLO view and 78% (n = 35) for the CC view. For the study cohort, cases presented with a median of four marks per cases (range 0-13). Eighty-four percent (n = 38) of lesions proceeded to excision; initial needle biopsy pathology was upgraded at surgical excision from in situ disease to invasive for 24% (n = 9) lesions. CAD has demonstrated the potential to detect mammographically visible cancers in multiple standard mammographic projections in all categories of lesions in this study cohort. (orig.)

  11. ROCK-CAD - computer aided geological modelling system

    International Nuclear Information System (INIS)

    Saksa, P.

    1995-12-01

    The study discusses surface and solid modelling methods, their use and interfacing with geodata. Application software named ROCK-CAD suitable for geological bedrock modelling has been developed with support from Teollisuuden Voima Oy (TVO). It has been utilized in the Finnish site characterization programme for spent nuclear fuel waste disposal during the 1980s and 1990s. The system is based on the solid modelling technique. It comprises also rich functionality for the particular geological modelling scheme. The ROCK-CAD system provides, among other things, varying graphical vertical and horizontal intersections and perspective illustrations. The specially developed features are the application of the boundary representation modelling method, parametric object generation language and the discipline approach. The ROCK-CAD system has been utilized in modelling spatial distribution of rock types and fracturing structures in TVO's site characterization. The Olkiluoto site at Eurajoki serves as an example case. The study comprises the description of the modelling process, models and illustration examples. The utilization of bedrock models in site characterization, in tentative repository siting as well as in groundwater flow simulation is depicted. The application software has improved the assessment of the sites studied, given a new basis for the documentation of interpretation and modelling work, substituted hand-drawing and enabled digital transfer to numerical analysis. Finally, aspects of presentation graphics in geological modelling are considered. (84 refs., 30 figs., 11 tabs.)

  12. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    Science.gov (United States)

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.

  13. rCAD: A Novel Database Schema for the Comparative Analysis of RNA.

    Science.gov (United States)

    Ozer, Stuart; Doshi, Kishore J; Xu, Weijia; Gutell, Robin R

    2011-12-31

    Beyond its direct involvement in protein synthesis with mRNA, tRNA, and rRNA, RNA is now being appreciated for its significance in the overall metabolism and regulation of the cell. Comparative analysis has been very effective in the identification and characterization of RNA molecules, including the accurate prediction of their secondary structure. We are developing an integrative scalable data management and analysis system, the RNA Comparative Analysis Database (rCAD), implemented with SQL Server to support RNA comparative analysis. The platformagnostic database schema of rCAD captures the essential relationships between the different dimensions of information for RNA comparative analysis datasets. The rCAD implementation enables a variety of comparative analysis manipulations with multiple integrated data dimensions for advanced RNA comparative analysis workflows. In this paper, we describe details of the rCAD schema design and illustrate its usefulness with two usage scenarios.

  14. Using AutoCAD to improve the visibility of the organizational technological design

    Directory of Open Access Journals (Sweden)

    Lebedeva Irina Mikhailovna

    2014-01-01

    Full Text Available The article describes the issue of increasing the visibility of technological solutions in organizational-technological design. The ability to visualize the main stages of building process technology contributes to organic integration of all the requirements. A special role for the harmonious perception is played by correct display of the lighting facilities, shadowing. Realistic shadows help to analyze the rooms’ insolation of the designed facility and the surrounding areas. We give a justification for the use of AutoCAD in order to automate the process of visualizing the results of organizational-technological design. The author describes the methods of obtaining realistic natural lighting in AutoCAD without significantly increasing the complexity of the process. Engineering companies in 46 % of cases use the software AutoCAD in order to create construction plans. AutoCAD has a variety of possibilities and is constantly evolving. Continuation is one of the benefits of this program. AutoCAD is unique in terms of customization, because, apart from instruction languages, it has two built-in programming languages: AutoLISP and VisualBasic. Because of these specific features AutoCAD allows to create any applications related to graphics implementation. Constant monitoring of lightning changes allows finding the appropriate in terms of aesthetics, ergonomics and insolation decisions on planning and associating a building or structure to the environment. Solar lighting is simulated by a combination of several directional lightning point sources. The author offers a brief description of the program algorithm, which allows automatically managing lighting settings and creating a file with a realistic visualization of the design solutions.

  15. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

    Science.gov (United States)

    Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike

    2011-08-01

    The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p manufacture of four-unit FDPs.

  16. Implications of unchanged detection criteria with CAD as second reader of mammograms

    International Nuclear Information System (INIS)

    Bornefalk, Hans

    2006-01-01

    In this paper we address the use of computer-aided detection (CAD) systems as second readers in mammography. The approach is based on Bayesian decision theory and its implication for the choice of optimal operating points. The choice of a certain operating point along an ROC curve corresponds to a particular tradeoff between false positives and missed cancers. By minimizing a total risk function given this tradeoff, we determine optimal decision thresholds for the radiologist and CAD system when CAD is used as a second reader. We show that under very general circumstances, the performance of the sequential system is improved if the decision threshold of the latent human decision variable is increased compared to what it would have been in the absence of the CAD system. This means that an initial stricter decision criterion should be applied by the radiologist when CAD is used as a second reader than otherwise. First and foremost, the results in this paper should be interpreted qualitatively, but an attempt is made at quantifying the effect by tuning the model to a prospective study evaluating the use of CAD as a second reader. By making some necessary and plausible assumptions, we are able to estimate the effect of the resulting suboptimal operating point. In this study of 12 860 women, we estimate that a 15% reduction in callbacks for masses could have been achieved with only about a 1.5% relative decrease in sensitivity compared to that without using a stricter initial criterion by the radiologist. For microcalcifications the corresponding values are 7% and 0.2%

  17. CAD system applications to the nuclear fuel reprocessing facilities

    International Nuclear Information System (INIS)

    Morita, Eiji; Matsumoto, Tadakuni; Shikakura, Sakae; Furuya, Kousei; Sakurai, Shin-ichi.

    1994-01-01

    Effective supporting techniques of design, operation, and maintenance of the reprocessing facility have been developed using the Intergraph CAD system. Two and three dimensional views of the process cells were utilized to rationalize the equipment layout and material handling flows, and to check the piping interference. Interferences of the remote maintenance equipment with the process equipments were also evaluated by the pictures on the CAD display. The newest virtual reality technology will help our future development of the more natural simulation for the remote maintenance operator training. (author)

  18. Fracture and Fatigue Resistance of Cemented versus Fused CAD-on Veneers over Customized Zirconia Implant Abutments.

    Science.gov (United States)

    Nossair, Shereen Ahmed; Aboushelib, Moustafa N; Morsi, Tarek Salah

    2015-01-05

    To evaluate the fracture mechanics of cemented versus fused CAD-on veneers on customized zirconia implant abutments. Forty-five identical customized CAD/CAM zirconia implant abutments (0.5 mm thick) were prepared and seated on short titanium implant abutments (Ti base). A second scan was made to fabricate 45 CAD-on veneers (IPS Empress CAD, A2). Fifteen CAD-on veneers were cemented on the zirconia abutments (Panavia F2.0). Another 15 were fused to the zirconia abutments using low-fusing glass, while manually layered veneers served as control (n = 15). The restorations were subjected to artificial aging (3.2 million cycles between 5 and 10 kg in a water bath at 37°C) before being axially loaded to failure. Fractured specimens were examined using scanning electron microscopy to detect fracture origin, location, and size of critical crack. Stress at failure was calculated using fractography principles (alpha = 0.05). Cemented CAD-on restorations demonstrated significantly higher (F = 72, p CAD-on and manually layered restorations. Fractographic analysis of fractured specimens indicated that cemented CAD-on veneers failed due to radial cracks originating from the veneer/resin interface. Branching of the critical crack was observed in the bulk of the veneer. Fused CAD-on veneers demonstrated cohesive fracture originating at the thickest part of the veneer ceramic, while manually layered veneers failed due to interfacial fracture at the zirconia/veneer interface. Within the limitations of this study, cemented CAD-on veneers on customized zirconia implant abutments demonstrated higher fracture than fused and manually layered veneers. © 2014 by the American College of Prosthodontists.

  19. Evaluation of the potential benefit of computer-aided diagnosis (CAD) for lung cancer screening using photofluorography

    International Nuclear Information System (INIS)

    Matsumoto, Tsuneo; Nakamura, Hiroshi; Nakanishi, Takashi; Doi, Kunio; Kano, Akiko.

    1993-01-01

    To evaluate the potential benefit of computer-aided diagnosis (CAD) in lung cancer screenings using photofluorographic films, we performed an observer test with 12 radiologists. We used 60 photofluorographic films obtained from a lung cancer screening program in Yamaguchi Prefecture (30 contained cancerous nodules and 30 had no nodules). In these cases, our current automated detection scheme achieved a sensitivity of 80%, but yielded an average of 11 false-positives per image. The observer study consisted of three viewing conditions: 1) only the original image (single reading), 2) the original image and computer output obtained from the current CAD scheme (CAD 1), 3) the original image and computer output obtained from a simulated improved CAD scheme with the same 80% true-positive rate, but with an average of one false-positive per image (CAD 2). Compared with double reading using independent interpretations, which is based on a higher score between two single readings, CAD 2 was more sensitive in subtle cases. The specificity of CAD was superior to that of double reading. Although CAD 1 (Az=0.805) was inferior to double reading (Az=0.837) in terms of the ROC curve, CAD 2 (Az=0.872) significantly improved the ROC curve and also significantly reduced observation time (p<0.05). If the number of false positives can be reduced, computer-aided diagnosis may play an important role in lung cancer screening programs. (author)

  20. Three-Dimensional Digital Evaluation of the Fit of Endocrowns Fabricated from Different CAD/CAM Materials.

    Science.gov (United States)

    Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis

    2018-03-06

    A wide variety of CAD/CAM materials are available for single-tooth restorations. CAD/CAM material characteristics are different and may influence CAM fabrication accuracy. There is no study investigating the influence of different CAD/CAM materials on the final fit of the restoration. The aim of this study was to evaluate the fit of endocrowns fabricated from different CAD/CAM materials using a new 3D evaluation method with an intraoral scanning system. The null hypothesis was that there are no significant differences for the fitting accuracy of different CAD/CAM materials. Preparation for an endocrown was performed on a maxillary right first molar on a typodont, and restorations were fabricated with a chairside CAD/CAM system (CEREC Omnicam, MCXL). Three groups using three different CAD/CAM materials were established (each n = 10): zirconia-reinforced lithium silicate ceramic (Celtra Duo; CD), leucite-reinforced silicate ceramic (Empress CAD; EM), resin nanoceramic (Lava Ultimate; LU). A 3D digital measurement technique (OraCheck, Cyfex AG) using an intraoral scanner (CEREC Omnicam) was used to measure the difference in fit between the three materials for a master endocrown preparation. The preparation scan and the endocrown fit scan were matched with special difference analysis software OraCheck. Three areas were selected for fitting accuracy measurements: margin (MA), axial (AX), occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and post-hoc Scheffé test. Significance level was set to p = 0.05. Results varied from best 88.9 ± 7.7 μm for marginal fit of resin nanoceramic restorations (LU_MA) to worst 182.3 ± 24.0 μm for occlusal fit of zirconia-reinforced lithium silicate restorations (CD_OC). Statistically significant differences were found both within and among the test groups. Group CD performed statistically significantly different from group LU for marginal fit (MA) and axial fit (AX) (p 0.05). Deviation pattern for

  1. Up and running with AutoCAD 2013 2D and 3D drawing and modeling

    CERN Document Server

    Gindis, Elliot

    2012-01-01

    Gindis introduces AutoCAD with step by step instructions, stripping away complexities to  begin working in AutoCAD immediately.  All concepts are explained first in theory, and then shown in practice, helping the reader understand what it is they are doing and why, before they do it. Divided into three parts, the book covers beginning through advanced AutoCAD, including 3D features.  Also included is an extensive Appendix for each part, detailing additional useful CAD-related information not often found in other text books The book contains support

  2. Up and running with AutoCAD 2014 2D and 3D drawing and modeling

    CERN Document Server

    Gindis, Elliot

    2013-01-01

    Get ""Up and Running"" with AutoCAD using Gindis's combination of step-by-step instruction, examples, and insightful explanations. The emphasis from the beginning is on core concepts and practical application of AutoCAD in architecture, engineering and design. Equally useful in instructor-led classroom training, self-study, or as a professional reference, the book is written with the user in mind by a long-time AutoCAD professional and instructor based on what works in the industry and the classroom. Strips away complexities, both real and perceived, and reduces AutoCAD t

  3. SED-ML web tools: generate, modify and export standard-compliant simulation studies.

    Science.gov (United States)

    Bergmann, Frank T; Nickerson, David; Waltemath, Dagmar; Scharm, Martin

    2017-04-15

    The Simulation Experiment Description Markup Language (SED-ML) is a standardized format for exchanging simulation studies independently of software tools. We present the SED-ML Web Tools, an online application for creating, editing, simulating and validating SED-ML documents. The Web Tools implement all current SED-ML specifications and, thus, support complex modifications and co-simulation of models in SBML and CellML formats. Ultimately, the Web Tools lower the bar on working with SED-ML documents and help users create valid simulation descriptions. http://sysbioapps.dyndns.org/SED-ML_Web_Tools/ . fbergman@caltech.edu . © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  4. Predicting Long-term Ischemic Events Using Routine Clinical Parameters in Patients with Coronary Artery Disease: The OPT-CAD Risk Score.

    Science.gov (United States)

    Han, Yaling; Chen, Jiyan; Qiu, Miaohan; Li, Yi; Li, Jing; Feng, Yingqing; Qiu, Jian; Meng, Liang; Sun, Yihong; Tao, Guizhou; Wu, Zhaohui; Yang, Chunyu; Guo, Jincheng; Pu, Kui; Chen, Shaoliang; Wang, Xiaozeng

    2018-06-05

    The prognosis of patients with coronary artery disease (CAD) at hospital discharge was constantly varying, and post-discharge risk of ischemic events remain a concern. However, risk prediction tools to identify risk of ischemia for these patients has not yet been reported. We sought to develop a scoring system for predicting long-term ischemic events in CAD patients receiving antiplatelet therapy that would be beneficial in appropriate personalized decision-making for these patients. In this prospective Optimal antiPlatelet Therapy for Chinese patients with Coronary Artery Disease (OPT-CAD, NCT01735305) registry, a total of 14,032 patients with CAD receiving at least one kind of antiplatelet agent were enrolled from 107 centers across China, from January 2012 to March 2014. The risk scoring system was developed in a derivation cohort (enrolled initially 10,000 patients in the database) using a logistic regression model and was subsequently tested in a validation cohort (the last 4,032 patients). Points in risk score was assigned based on the multivariable odds ratio of each factor. Ischemic events were defined as the composite of cardiac death, myocardial infarction or stroke. Ischemic events occurred in 342 (3.4%) patients in the derivation cohort and 160 (4.0%) patients in the validation cohort during 1-year follow-up. The OPT-CAD score, ranging from 0-257 points, consist of 10 independent risk factors, including age (0-71 points), heart rates (0-36 points), hypertension (0-20 points), prior myocardial infarction (16 points), prior stroke (16 points), renal insufficient (21 points), anemia (19 points), low ejection fraction (22 points), positive cardiac troponin (23 points) and ST-segment deviation (13 points). In predicting 1-year ischemic events, the area under receiver operating characteristics curve were 0.73 and 0.72 in derivation and validation cohort, respectively. The incidences of ischemic events in low- (0-90 points), medium- (91-150 points) and

  5. Detection and function of an intramolecular disulfide bond in the pH-responsive CadC of Escherichia coli

    Directory of Open Access Journals (Sweden)

    Dönhöfer Alexandra

    2011-04-01

    Full Text Available Abstract Background In an acidic and lysine-rich environment Escherichia coli induces expression of the cadBA operon which encodes CadA, the lysine decarboxylase, and CadB, the lysine/cadaverine antiporter. cadBA expression is dependent on CadC, a membrane-integrated transcriptional activator which belongs to the ToxR-like protein family. Activation of CadC requires two stimuli, lysine and low pH. Whereas lysine is detected by an interplay between CadC and the lysine-specific transporter LysP, pH alterations are sensed by CadC directly. Crystal structural analyses revealed a close proximity between two periplasmic cysteines, Cys208 and Cys272. Results Substitution of Cys208 and/or Cys272 by alanine resulted in CadC derivatives that were active in response to only one stimulus, either lysine or pH 5.8. Differential in vivo thiol trapping revealed a disulfide bond between these two residues at pH 7.6, but not at pH 5.8. When Cys208 and Cys272 were replaced by aspartate and lysine, respectively, virtually wild-type behavior was restored indicating that the disulfide bond could be mimicked by a salt bridge. Conclusion A disulfide bond was found in the periplasmic domain of CadC that supports an inactive state of CadC at pH 7.6. At pH 5.8 disulfide bond formation is prevented which transforms CadC into a semi-active state. These results provide new insights into the function of a pH sensor.

  6. A Student Assessment Tool for Standardized Patient Simulations (SAT-SPS): Psychometric analysis.

    Science.gov (United States)

    Castro-Yuste, Cristina; García-Cabanillas, María José; Rodríguez-Cornejo, María Jesús; Carnicer-Fuentes, Concepción; Paloma-Castro, Olga; Moreno-Corral, Luis Javier

    2018-05-01

    The evaluation of the level of clinical competence acquired by the student is a complex process that must meet various requirements to ensure its quality. The psychometric analysis of the data collected by the assessment tools used is a fundamental aspect to guarantee the student's competence level. To conduct a psychometric analysis of an instrument which assesses clinical competence in nursing students at simulation stations with standardized patients in OSCE-format tests. The construct of clinical competence was operationalized as a set of observable and measurable behaviors, measured by the newly-created Student Assessment Tool for Standardized Patient Simulations (SAT-SPS), which was comprised of 27 items. The categories assigned to the items were 'incorrect or not performed' (0), 'acceptable' (1), and 'correct' (2). 499 nursing students. Data were collected by two independent observers during the assessment of the students' performance at a four-station OSCE with standardized patients. Descriptive statistics were used to summarize the variables. The difficulty levels and floor and ceiling effects were determined for each item. Reliability was analyzed using internal consistency and inter-observer reliability. The validity analysis was performed considering face validity, content and construct validity (through exploratory factor analysis), and criterion validity. Internal reliability and inter-observer reliability were higher than 0.80. The construct validity analysis suggested a three-factor model accounting for 37.1% of the variance. These three factors were named 'Nursing process', 'Communication skills', and 'Safe practice'. A significant correlation was found between the scores obtained and the students' grades in general, as well as with the grades obtained in subjects with clinical content. The assessment tool has proven to be sufficiently reliable and valid for the assessment of the clinical competence of nursing students using standardized patients

  7. Grinding damage assessment for CAD-CAM restorative materials.

    Science.gov (United States)

    Curran, Philippe; Cattani-Lorente, Maria; Anselm Wiskott, H W; Durual, Stéphane; Scherrer, Susanne S

    2017-03-01

    To assess surface/subsurface damage after grinding with diamond discs on five CAD-CAM restorative materials and to estimate potential losses in strength based on crack size measurements of the generated damage. The materials tested were: Lithium disilicate (LIT) glass-ceramic (e.max CAD), leucite glass-ceramic (LEU) (Empress CAD), feldspar ceramic (VM2) (Vita Mark II), feldspar ceramic-resin infiltrated (EN) (Enamic) and a composite reinforced with nano ceramics (LU) (Lava Ultimate). Specimens were cut from CAD-CAM blocs and pair-wise mirror polished for the bonded interface technique. Top surfaces were ground with diamond discs of respectively 75, 54 and 18μm. Chip damage was measured on the bonded interface using SEM. Fracture mechanics relationships were used to estimate fracture stresses based on average and maximum chip depths assuming these to represent strength limiting flaws subjected to tension and to calculate potential losses in strength compared to manufacturer's data. Grinding with a 75μm diamond disc induced on a bonded interface critical chips averaging 100μm with a potential strength loss estimated between 33% and 54% for all three glass-ceramics (LIT, LEU, VM2). The softer materials EN and LU were little damage susceptible with chips averaging respectively 26μm and 17μm with no loss in strength. Grinding with 18μm diamond discs was still quite detrimental for LIT with average chip sizes of 43μm and a potential strength loss of 42%. It is essential to understand that when grinding glass-ceramics or feldspar ceramics with diamond discs surface and subsurface damage are induced which have the potential of lowering the strength of the ceramic. Careful polishing steps should be carried out after grinding especially when dealing with glass-ceramics. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  8. Standard guide for hot cell specialized support equipment and tools

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 Intent: 1.1.1 This guide presents practices and guidelines for the design and implementation of equipment and tools to assist assembly, disassembly, alignment, fastening, maintenance, or general handling of equipment in a hot cell. Operating in a remote hot cell environment significantly increases the difficulty and time required to perform a task compared to completing a similar task directly by hand. Successful specialized support equipment and tools minimize the required effort, reduce risks, and increase operating efficiencies. 1.2 Applicability: 1.2.1 This guide may apply to the design of specialized support equipment and tools anywhere it is remotely operated, maintained, and viewed through shielding windows or by other remote viewing systems. 1.2.2 Consideration should be given to the need for specialized support equipment and tools early in the design process. 1.2.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conv...

  9. The effect of milling and postmilling procedures on the surface roughness of CAD/CAM materials.

    Science.gov (United States)

    Mota, Eduardo Gonçalves; Smidt, Laura Nunes; Fracasso, Lisiane Martins; Burnett, Luiz Henrique; Spohr, Ana Maria

    2017-11-12

    The aim of this study was to evaluate the surface roughness and analyze the surface topography of five different CAD/CAM ceramics and one CAD/CAM composite resin for CEREC after milling and postmilling procedures. Blocks of the ceramics Mark II, IPS Empress CAD, IPS e.max CAD, Suprinity and Enamic, and blocks of the composite resin Lava Ultimate were milled at CEREC MCXL. Ten flat samples of each material were obtained. The surface roughness (Ra) test was performed before and after milling, crystallization, polishing, and glaze when indicated, followed by SEM and AFM analysis. Data were submitted to one-way ANOVA with repeated measures and the Tukey HSD test (α = 0.05). The milling step significantly increased the roughness of all the tested materials (P CAD and Suprinity) were more suitable to roughness than the other tested materials (P CAD/CAM materials, that is, fully sintered, should be only hand polished. The glaze step can be suppressed resulting in time saving. However, the glaze step in soft-milling lithium disilicate is imperative. © 2017 Wiley Periodicals, Inc.

  10. Springback Simulation and Tool Surface Compensation Algorithm for Sheet Metal Forming

    International Nuclear Information System (INIS)

    Shen Guozhe; Hu Ping; Zhang Xiangkui; Chen Xiaobin; Li Xiaoda

    2005-01-01

    Springback is an unquenchable forming defect in the sheet metal forming process. How to calculate springback accurately is a big challenge for a lot of FEA software. Springback compensation makes the stamped final part accordant with the designed part shape by modifying tool surface, which depends on the accurate springback amount. How ever, the meshing data based on numerical simulation is expressed by nodes and elements, such data can not be supplied directly to tool surface CAD data. In this paper, a tool surface compensation algorithm based on numerical simulation technique of springback process is proposed in which the independently developed dynamic explicit springback algorithm (DESA) is used to simulate springback amount. When doing the tool surface compensation, the springback amount of the projected point can be obtained by interpolation of the springback amount of the projected element nodes. So the modified values of tool surface can be calculated reversely. After repeating the springback and compensation calculations for 1∼3 times, the reasonable tool surface mesh is gained. Finally, the FEM data on the compensated tool surface is fitted into the surface by CAD modeling software. The examination of a real industrial part shows the validity of the present method

  11. Stress Perfusion Coronary Flow Reserve Versus Cardiac Magnetic Resonance for Known or Suspected CAD.

    Science.gov (United States)

    Kato, Shingo; Saito, Naka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Taguri, Masataka; Kosuge, Masami; Kimura, Kazuo

    2017-08-15

    Phase-contrast (PC) cine magnetic resonance imaging (MRI) of the coronary sinus is a noninvasive method to quantify coronary flow reserve (CFR). This study sought to compare the prognostic value of CFR by cardiac magnetic resonance (CMR) and stress perfusion CMR to predict major adverse cardiac events (MACE). Participants included 276 patients with known coronary artery disease (CAD) and 400 with suspected CAD. CFR was calculated as myocardial blood flow during adenosine triphosphate infusion divided by myocardial blood flow at rest using PC cine MRI of the coronary sinus. During a median follow-up of 2.3 years, 47 patients (7%) experienced MACE. Impaired CFR (10% ischemia on stress perfusion CMR were significantly associated with MACE in patients with known CAD (hazard ratio [HR]: 5.17 and HR: 5.10, respectively) and suspected CAD (HR: 14.16 and HR: 6.50, respectively). The area under the curve for predicting MACE was 0.773 for CFR and 0.731 for stress perfusion CMR (p = 0.58) for patients with known CAD, and 0.885 for CFR and 0.776 for stress perfusion CMR (p = 0.059) in the group with suspected CAD. In patients with known CAD, sensitivity, specificity, and positive and negative predictive values to predict MACE were 64%, 91%, 38%, and 97%, respectively, for CFR, and 82%, 59%, 15%, and 97%, respectively, for stress perfusion CMR. In the suspected CAD group, these values were 65%, 99%, 80%, and 97%, respectively, for CFR, and 72%, 83%, 22%, and 98%, respectively, for stress perfusion CMR. The predictive values of CFR and stress perfusion CMR for MACE were comparable in patients with known CAD. In patients with suspected CAD, CFR showed higher HRs and areas under the curve than stress perfusion CMR, suggesting that CFR assessment by PC cine MRI might provide better risk stratification for patients with suspected CAD. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Automated Design Tools for Integrated Mixed-Signal Microsystems (NeoCAD)

    National Research Council Canada - National Science Library

    Petre, P; Visher, J; Shringarpure, R; Valley, F; Swaminathan, M

    2005-01-01

    Automated design tools and integrated design flow methodologies were developed that demonstrated more than an order- of-magnitude reduction in cycle time and cost for mixed signal (digital/analoglRF...

  13. Up and Running with AutoCAD 2011 2D and 3D Drawing and Modeling

    CERN Document Server

    Gindis, Elliot

    2010-01-01

    Gindis introduces AutoCAD with step by step instructions, stripping away complexities to  begin working in AutoCAD immediately.  All concepts are explained first in theory, and then shown in practice, helping the reader understand what it is they are doing and why, before they do it. Divided into three parts, the book covers beginning through advanced AutoCAD, including 3D features.  Also included is an extensive Appendix for each part, detailing additional useful CAD-related information not often found in other text books The book contains supporting graphics (screen shot

  14. Up and Running with AutoCAD 2012 2D and 3D Drawing and Modeling

    CERN Document Server

    Gindis, Elliot

    2011-01-01

    Gindis introduces AutoCAD with step by step instructions, stripping away complexities to  begin working in AutoCAD immediately.  All concepts are explained first in theory, and then shown in practice, helping the reader understand what it is they are doing and why, before they do it. Divided into three parts, the book covers beginning through advanced AutoCAD, including 3D features.  Also included is an extensive Appendix for each part, detailing additional useful CAD-related information not often found in other text books The book contains supporting graphics (screen shot

  15. Functional characterization of a cadmium resistance operon in Staphylococcus aureus ATCC12600: CadC does not function as a repressor.

    Science.gov (United States)

    Hoogewerf, Arlene J; Dyk, Lisa A Van; Buit, Tyler S; Roukema, David; Resseguie, Emily; Plaisier, Christina; Le, Nga; Heeringa, Lee; Griend, Douglas A Vander

    2015-02-01

    Sequencing of a cadmium resistance operon from a Staphylococcus aureus ATCC12600 plasmid revealed that it is identical to a cadCA operon found in MRSA strains. Compared to plasmid-cured and cadC-mutant strains, cadC-positive ATCC12600 cells had increased resistance to cadmium (1 mg ml(-1) cadmium sulfate) and zinc (4 mg ml(-1) zinc sulfate), but not to other metal ions. After growth in media containing 20 µg ml(-1) cadmium sulfate, cadC-mutant cells contained more intracellular cadmium than cadC-positive ATCC12600 cells, suggesting that cadC absence results in impaired cadmium efflux. Electrophoretic mobility shift assays were performed with CadC proteins encoded by the S. aureus ATCC12600 plasmid and by the cadC gene of pI258, which is known to act as a transcriptional repressor and shares only 47% protein sequence identity with ATCC12600 CadC. Mobility shifts occurred when pI258 CadC protein was incubated with the promoter DNA-regions from the pI258 and S. aureus ATCC12600 cadCA operons, but did not occur with S. aureus ATCC12600 CadC protein, indicating that the ATCC12600 CadC protein does not interact with promoter region DNA. This cadCA operon, found in MRSA strains and previously functionally uncharacterized, increases resistance to cadmium and zinc by an efflux mechanism, and CadC does not function as a transcriptional repressor. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.

    Science.gov (United States)

    Lee, Wan-Sun; Lee, Du-Hyeong; Lee, Kyu-Bok

    2017-08-01

    This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) µm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) µm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

  17. A CAD based geometry model for simulation and analysis of particle detector data

    Energy Technology Data Exchange (ETDEWEB)

    Milde, Michael; Losekamm, Martin; Poeschl, Thomas; Greenwald, Daniel; Paul, Stephan [Technische Universitaet Muenchen, 85748 Garching (Germany)

    2016-07-01

    The development of a new particle detector requires a good understanding of its setup. A detailed model of the detector's geometry is not only needed during construction, but also for simulation and data analysis. To arrive at a consistent description of the detector geometry a representation is needed that can be easily implemented in different software tools used during data analysis. We developed a geometry representation based on CAD files that can be easily used within the Geant4 simulation framework and analysis tools based on the ROOT framework. This talk presents the structure of the geometry model and show its implementation using the example of the event reconstruction developed for the Multi-purpose Active-target Particle Telescope (MAPT). The detector consists of scintillating plastic fibers and can be used as a tracking detector and calorimeter with omnidirectional acceptance. To optimize the angular resolution and the energy reconstruction of measured particles, a detailed detector model is needed at all stages of the reconstruction.

  18. Improving digital breast tomosynthesis reading time: A pilot multi-reader, multi-case study using concurrent Computer-Aided Detection (CAD).

    Science.gov (United States)

    Balleyguier, Corinne; Arfi-Rouche, Julia; Levy, Laurent; Toubiana, Patrick R; Cohen-Scali, Franck; Toledano, Alicia Y; Boyer, Bruno

    2017-12-01

    Evaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time. The CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0-100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive. Average AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: -0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0-37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: -0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: -0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a -0

  19. Mixed-Dimensionality VLSI-Type Configurable Tools for Virtual Prototyping of Biomicrofluidic Devices and Integrated Systems

    Science.gov (United States)

    Makhijani, Vinod B.; Przekwas, Andrzej J.

    2002-10-01

    This report presents results of a DARPA/MTO Composite CAD Project aimed to develop a comprehensive microsystem CAD environment, CFD-ACE+ Multiphysics, for bio and microfluidic devices and complete microsystems. The project began in July 1998, and was a three-year team effort between CFD Research Corporation, California Institute of Technology (CalTech), University of California, Berkeley (UCB), and Tanner Research, with Mr. Don Verlee from Abbott Labs participating as a consultant on the project. The overall objective of this project was to develop, validate and demonstrate several applications of a user-configurable VLSI-type mixed-dimensionality software tool for design of biomicrofluidics devices and integrated systems. The developed tool would provide high fidelity 3-D multiphysics modeling capability, l-D fluidic circuits modeling, and SPICE interface for system level simulations, and mixed-dimensionality design. It would combine tools for layouts and process fabrication, geometric modeling, and automated grid generation, and interfaces to EDA tools (e.g. Cadence) and MCAD tools (e.g. ProE).

  20. Analysis on the workspace of palletizing robot based on AutoCAD

    Science.gov (United States)

    Li, Jin-quan; Zhang, Rui; Guan, Qi; Cui, Fang; Chen, Kuan

    2017-10-01

    In this paper, a four-degree-of-freedom articulated palletizing robot is used as the object of research. Based on the analysis of the overall configuration of the robot, the kinematic mathematical model is established by D-H method to figure out the workspace of the robot. In order to meet the needs of design and analysis, using AutoCAD secondary development technology and AutoLisp language to develop AutoCAD-based 2D and 3D workspace simulation interface program of palletizing robot. At last, using AutoCAD plugin, the influence of structural parameters on the shape and position of the working space is analyzed when the structure parameters of the robot are changed separately. This study laid the foundation for the design, control and planning of palletizing robots.

  1. [Establishment of database with standard 3D tooth crowns based on 3DS MAX].

    Science.gov (United States)

    Cheng, Xiaosheng; An, Tao; Liao, Wenhe; Dai, Ning; Yu, Qing; Lu, Peijun

    2009-08-01

    The database with standard 3D tooth crowns has laid the groundwork for dental CAD/CAM system. In this paper, we design the standard tooth crowns in 3DS MAX 9.0 and create a database with these models successfully. Firstly, some key lines are collected from standard tooth pictures. Then we use 3DS MAX 9.0 to design the digital tooth model based on these lines. During the design process, it is important to refer to the standard plaster tooth model. After some tests, the standard tooth models designed with this method are accurate and adaptable; furthermore, it is very easy to perform some operations on the models such as deforming and translating. This method provides a new idea to build the database with standard 3D tooth crowns and a basis for dental CAD/CAM system.

  2. Roughness, surface energy, and superficial damages of CAD/CAM materials after surface treatment.

    Science.gov (United States)

    Strasser, Thomas; Preis, Verena; Behr, Michael; Rosentritt, Martin

    2018-02-05

    The aim of this study was to examine the effects of surface pre-treatment on CAD/CAM materials including ceramics, zirconia, resin-infiltrated ceramic, and resin-based composite. Specimens were made of ten CAD/CAM materials (Celtra Duo, Degudent, D; Vita Suprinity, Vita, D; E.max CAD, Ivoclar-Vivadent, FL; E.max ZirCAD, Ivoclar-Vivadent, FL; Vita Enamic, Vita, D; Cerasmart, GC, B; LAVA Ultimate, 3M, D; SHOFU Block HC, SHOFU, US; Grandio Blocs, VOCO, D; BRILLIANT Crios, Coltene, CH) and pretreated to represent clinical procedures (Hf 20 s/5%; phosphoric acid 20 s/37%; Monobond etch and prime (Ivoclar-Vivadent, FL); water-cooled diamond bur (80 μm; 4 μm); Al 2 O 3 -blasting (50 μm/1 bar, 50 μm/2 bar, 120 μm/1 bar, 120 μm/2 bar); untreated; manufacturer's instructions). SEM-analysis (Phenom, FEI, NL) of the surfaces was performed (magnifications ≤ 10,000×). Roughness values R a , R z (KJ 3D, Keyence, J), and surface energy SE (OCA15 plus, SCA20, DataPhysics, D) were determined (statistics: non-parametric Mann-Whitney U test/Kruskal-Wallis test for independent specimen, α = 0.05). Kruskal-Wallis revealed significant (p CAD/CAM materials require individual pre-treatment for optimized and protective surface activation. Cementation is a key factor for clinical success. Given the variety of available CAD/CAM materials, specific procedures are needed.

  3. Mechanical properties of resin-ceramic CAD/CAM restorative materials.

    Science.gov (United States)

    Awada, Abdallah; Nathanson, Dan

    2015-10-01

    The recent development of polymer-based computer-aided design and computer-aided manufactured (CAD/CAM) milling blocks and the limited availability of independent studies on these materials make it pertinent to evaluate their properties and identify potential strengths and limitations. The purpose of this in vitro study was to determine and compare mechanical properties (flexural strength, flexural modulus, modulus of resilience) and compare the margin edge quality of recently introduced polymer-based CAD/CAM materials with some of their commercially available composite resin and ceramic counterparts. The materials studied were Lava Ultimate Restorative (LVU; 3M ESPE), Enamic (ENA; Vita Zahnfabrik), Cerasmart (CES; GC Dental Products), IPS Empress CAD (EMP; Ivoclar Vivadent AG), Vitablocs Mark II (VM2; Vita Zahnfabrik), and Paradigm MZ100 Block (MZ1; 3M ESPE). Polished 4×1×13.5 mm bars (n=25) were prepared from standard-sized milling blocks of each tested material. The bars were subjected to a 3-point flexural test on a 10-mm span with a crosshead speed of 0.5 mm/min. In addition, 42 conventional monolithic crowns (7 per material) were milled. Margin edge quality was observed by means of macrophotography and optical microscopy, providing a qualitative visual assessment and a measurement of existing roughness. The results were analyzed by ANOVA followed by the Tukey HSD test (α=.05). The mean flexural strength of the tested materials ranged from 105 ±9 MPa (VM2) to 219 ±20 MPa (CES). The mean flexural modulus ranged from 8 ±0.25 GPa (CES) to 32 ±1.9 GPa (EMP). The mean modulus of resilience ranged from 0.21 ±0.02 MPa (VM2) to 3.07 ±0.45 MPa (CES). The qualitative assessment of margin edge roughness revealed visible differences among the tested materials, with mean roughness measurements ranging from 60 ±16 μm (CES) to 190 ±15 μm (EMP). The material factor had a significant effect on the mean flexural strength (Pmaterials tested in this study exhibited

  4. Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

    International Nuclear Information System (INIS)

    Giger, Maryellen L.; Chan, Heang-Ping; Boone, John

    2008-01-01

    algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.

  5. Variation in CAD Secondary Prevention Prescription among Outpatient Cardiology Practices: Insights from the NCDR®

    Science.gov (United States)

    Maddox, Thomas M.; Chan, Paul S.; Spertus, John A.; Tang, Fengming; Jones, Phil; Ho, P. Michael; Bradley, Steven M.; Tsai, Thomas T.; Bhatt, Deepak L.; Peterson, Pamela N.

    2014-01-01

    Objectives This study assesses practice variation of secondary prevention medication prescription among coronary artery disease (CAD) patients treated in outpatient practices participating in the NCDR® PINNACLE Registry®. Background Among patients with CAD, secondary prevention with a combination of beta-blockers, angiotensin converting enzyme inhibitors/angiotensin receptor blockers, and statins reduces cardiac mortality and myocardial infarction (MI). Accordingly, every CAD patient should receive the combination of these medications for which they are eligible. However, little is known about current prescription patterns of these medications and the variation in use among outpatient cardiology clinics. Methods Using data from NCDR® PINNACLE Registry®, a national outpatient cardiology practice registry, we assessed medication prescription patterns among eligible CAD patients between July 2008 and December 2010. Overall rates of prescription and variation by practice were calculated, adjusting for patient characteristics. Results Among 156,145 CAD patients in 58 practices, 103,830 (66.5%) were prescribed the optimal combination of medications for which they were eligible. The median rate of optimal combined prescription by practice was 73.5% and varied from 28.8% to 100%. After adjustment for patient factors, the practice median rate ratio for prescription was 1.25 (95% CI 1.2,1.32), indicating a 25% likelihood that 2 random practices would differ in treating identical CAD patients. Conclusions Among a national registry of CAD patients treated in outpatient cardiology practices, over one-third of patients failed to receive their optimal combination of secondary prevention medications. Significant variation was observed across practices, even after adjusting for patient characteristics, suggesting that quality improvement efforts may be needed to support more uniform practice. PMID:24184238

  6. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.

    Science.gov (United States)

    Alammari, Manal Rahma

    2017-10-01

    Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and pCAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental

  7. The Association between Androgenic Hormone Levels and the Risk of Developing Coronary Artery Disease (CAD).

    Science.gov (United States)

    Allameh, Farzad; Pourmand, Gholamreza; Bozorgi, Ali; Nekuie, Sepideh; Namdari, Farshad

    2016-01-01

    The aim of the study was to evaluate the relationship between the serum levels of androgens and Coronary Artery Disease (CAD) in an Iranian population. Male individuals admitted to Tehran Heart Center and Sina Hospital, Tehran, Iran from 2011-2012 were categorized into CAD and control groups based on selective coronary angiography. Baseline demographic data, including age, BMI, diabetes, and a history of hypertension were recorded. Patients were also assessed for their serum levels of total testosterone, free testosterone, estradiol, dehydroepi and rosterone sulfate (DHEA-S), and Sex Hormone Binding Globulin (SHBG). Data analysis was carried out chi-square and ANOVA tests as well as logistic regression analysis. Two hundred patients were in the CAD group and 135 individuals in control group. In the CAD group, 69 had single-vessel disease, 49 had two-vessel diseases, and 82 had three-vessel diseases. Statistically significant differences were observed between the individuals in the two groups with respect to age (PCAD group; however, the serum level of SHBG was higher in the CAD group than in the control group (P=0.007). Results of the logistic regression analysis indicated that only age (P=0.042) and diabetes (P=0.003) had significant relationships with CAD. Although the serum levels of some of the androgens were significantly different between the two groups, no association was found between androgenic hormone levels and the risk of CAD, due mainly to the effect of age and diabetes.

  8. Building of a CAD system for instrumentation and control system of nuclear power plant

    International Nuclear Information System (INIS)

    Ma Zhicai; Hu Chunping; Zhang Dongsheng

    2012-01-01

    Base on the analysis of deign documents and process, a database for instrumentation and control system design can be developed with a popular desktop relational database management system (RDBMS). With the RDBMS, an instrumentation and control system CAD system can be built unitizing database link feature of popular CAD software, with the function of management of design data, output of list and forms. and design of drawings. A CAD system of this kind has been used in the design practice of nuclear power plant. With this system, it is shown that, the consistency of information has been controlled and the load on the engineer has been significantly reduced. The methodology used here can also be used in the CAD system for CAP1000 and CAP1400 plant. (authors) series

  9. Monte Carlo tools for Beyond the Standard Model Physics , April 14-16

    DEFF Research Database (Denmark)

    Badger...[], Simon; Christensen, Christian Holm; Dalsgaard, Hans Hjersing

    2011-01-01

    This workshop aims to gather together theorists and experimentalists interested in developing and using Monte Carlo tools for Beyond the Standard Model Physics in an attempt to be prepared for the analysis of data focusing on the Large Hadron Collider. Since a large number of excellent tools....... To identify promising models (or processes) for which the tools have not yet been constructed and start filling up these gaps. To propose ways to streamline the process of going from models to events, i.e. to make the process more user-friendly so that more people can get involved and perform serious collider...

  10. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    Science.gov (United States)

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  11. From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites.

    Science.gov (United States)

    Mainjot, A K; Dupont, N M; Oudkerk, J C; Dewael, T Y; Sadoun, M J

    2016-05-01

    Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design-computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks-especially high temperature (HT) and, most of all, high temperature-high pressure (HT-HP)-are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks-particularly experimental PICNs-can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as "no prep" treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial

  12. METABOLIC AND AUTOIMMUNE RISK FACTORS FOR CORONARY ARTERY DISEASE (CAD IN HEART TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    T. A. Khalilulin

    2010-01-01

    Full Text Available One of the most essential autoimmunity risk factors for development of CAD are increasing level of anticardiolipin antibodies and homocystein. This report presents retrospective analyses of 39 heart transplant recipients with maximal follow up over 16 years. Our results showed that hyperhomocystenemia and high levels of anticardiolipin antibodies play great value in development of CAD. Thus relative risks for development of CAD in presence both high levels of anticardiolipin antibodies and homocysteine are higher, than in traditional nonimmune risk factors. 

  13. Is computer aided detection (CAD) cost effective in screening mammography? A model based on the CADET II study

    Science.gov (United States)

    2011-01-01

    Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study

  14. The efficacy of using CAD for detection of breast cancer in mammography screening A systematic review

    DEFF Research Database (Denmark)

    Henriksen, Emilie; Lauridsen, Carsten Ammitzbøl

    Abstract Purpose: The aim of this systematic review is to present an overview of the available studies concerning the use of computer-aided detection (CAD) systems in screening mammography for early detection of breast cancer and compare the diagnostic accuracy and recall rates of single reading....... The literature search resulted in 1522 records after duplicates were removed. 1491 records were excluded by abstract and 18 were excluded after assessing the eligibility by full text reading. A total of 13 articles were included in this study. Results: The results for the single reading vs. single reading...... with CAD group indicate that the addition of CAD increases sensitivity and cancer detection rate (CDR). For the double reading vs. single reading with CAD group none of the studies reported significant differences in sensitivity and CDR. Adding CAD to single reading increased the recall rates and decreased...

  15. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening: a systematic review.

    Science.gov (United States)

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.

  16. Pou5f1-dependent EGF expression controls E-cad endocytosis, cell adhesion, and zebrafish epiboly movements

    Science.gov (United States)

    Song, Sungmin; Eckerle, Stephanie; Onichtchouk, Daria; Marrs, James A.; Nitschke, Roland; Driever, Wolfgang

    2013-01-01

    Summary Initiation of motile cell behavior in embryonic development occurs during late blastula stages when gastrulation begins. At this stage, the strong adhesion of blastomeres has to be modulated to enable dynamic behavior, similar to epithelial-to-mesenchymal transitions. We show that in zebrafish MZspg embryos mutant for the stem cell transcription factor Pou5f1/Oct4, which are severely delayed in the epiboly gastrulation movement, all blastomeres are defective in E-cad endosomal trafficking and E-cad accumulates at the plasma membrane. We find that Pou5f1-dependent control of EGF expression regulates endosomal E-cad trafficking. EGFR may act via modulation of p120 activity. Loss of E-cad dynamics reduces cohesion of cells in reaggregation assays. Quantitative analysis of cell behavior indicates that dynamic E-cad endosomal trafficking is required for epiboly cell movements. We hypothesize that dynamic control of E-cad trafficking is essential to effectively generate new adhesion sites when cells move relative to each other. PMID:23484854

  17. Productivity increase through implementation of CAD/CAE workstation

    Science.gov (United States)

    Bromley, L. K.

    1985-01-01

    The tracking and communication division computer aided design/computer aided engineering system is now operational. The system is utilized in an effort to automate certain tasks that were previously performed manually. These tasks include detailed test configuration diagrams of systems under certification test in the ESTL, floorplan layouts of future planned laboratory reconfigurations, and other graphical documentation of division activities. The significant time savings achieved with this CAD/CAE system are examined: (1) input of drawings and diagrams; (2) editing of initial drawings; (3) accessibility of the data; and (4) added versatility. It is shown that the Applicon CAD/CAE system, with its ease of input and editing, the accessibility of data, and its added versatility, has made more efficient many of the necessary but often time-consuming tasks associated with engineering design and testing.

  18. Reducing bending stress in external spur gears by redesign of the standard cutting tool

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2009-01-01

    For the design of gears the stress due to bending plays a significant role. The stress from bending is largest in the root of the gear teeth, and the magnitude of the maximum stress is controlled by the nominal bending stress and stress concentration due to the geometric shape of the tooth....... In this work the bending stress of involute teeth is minimized by shape optimizing the tip of the standard cutting tool. By redesign of the tip of the standard cutting tool we achieve that the functional part of the teeth stays the same while at the same time the root shape is changed so that a reduction...... of the stresses results. The tool tip shape is described by different parameterizations that use the super ellipse as the central shape. For shape optimization it is important that the shape is given analytically. The shape of the cut tooth that is the envelope of the cutting tool is found analytically...

  19. Building of a CAD system for I and C system of nuclear power plant

    International Nuclear Information System (INIS)

    Ma Zhicai; Zhang Dongsheng

    2013-01-01

    An I and C database was developed based on the design objects and properties presented in I and C design documents of nuclear power plant. With the database, a rapid-implemented CAD system for I and C engineering was designed and implemented with popular CAD software, AutoCAD and Visio, and desktop database management system, Access, to manage the design data and to automate the composing task for listings, forms and drawings. This system was applied in an engineering project for data management, document generation and drawing aid, and demonstrated its usability and efficiency. (authors)

  20. Fracture analysis of CAD-CAM high-density polymers used for interim implant-supported fixed, cantilevered prostheses.

    Science.gov (United States)

    Yilmaz, Burak; Alp, Gülce; Seidt, Jeremy; Johnston, William M; Vitter, Roger; McGlumphy, Edwin A

    2018-01-06

    The load-to-fracture performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high-density polymer (HDP) materials in cantilevers is unknown. The purposes of this in vitro study were to evaluate the load-to-fracture performance of CAD-CAM-fabricated HDPs and to compare that with performance of autopolymerized and injection-molded acrylic resins. Specimens from 8 different brands of CAD-CAM HDPs, including Brylic Solid (BS); Brylic Gradient (BG); AnaxCAD Temp EZ (AE); AnaxCAD Temp Plus (AP); Zirkonzahn Temp Basic (Z); GDS Tempo-CAD (GD); Polident (Po); Merz M-PM-Disc (MAT); an autopolymerized acrylic resin, Imident (Conv) and an injection-molded acrylic resin, SR-IvoBase High Impact (Inj) were evaluated for load-to-fracture analysis (n=5). CAD-CAM specimens were milled from poly(methyl methacrylate) (PMMA) blocks measuring 7 mm in buccolingual width, 8 mm in occlusocervical thickness, and 30 mm in length. A wax pattern was prepared in the same dimensions used for CAD-CAM specimens, flasked, and boiled out. Autopolymerizing acrylic resin was packed and polymerized in a pressure container for 30 minutes. An identical wax pattern was flasked and boiled out, and premeasured capsules were injected (SR-IvoBase) and polymerized under hydraulic pressure for 35 minutes for the injection-molded PMMA. Specimens were thermocycled 5000 times (5°C to 55°C) and fixed to a universal testing machine to receive static loads on the 10-mm cantilever, vertically at a 1 mm/min crosshead speed until fracture occurred. Maximum load-to-fracture values were recorded. ANOVA was used to analyze the maximum force values. Significant differences among materials were analyzed by using the Ryan-Einot-Gabriel-Welsch multiple range test (α=.05). Statistically significant differences were found among load-to-fracture values of different HDPs (PCAD-CAM polymer. GD and Po CAD-CAM materials had the highest load-to-fracture values. AE, AP, Z, MAT, and BS CAD-CAM polymers

  1. 3D-CAD Effects on Creative Design Performance of Different Spatial Abilities Students

    Science.gov (United States)

    Chang, Y.

    2014-01-01

    Students' creativity is an important focus globally and is interrelated with students' spatial abilities. Additionally, three-dimensional computer-assisted drawing (3D-CAD) overcomes barriers to spatial expression during the creative design process. Does 3D-CAD affect students' creative abilities? The purpose of this study was to explore the…

  2. Ovulation leads women to perceive sexy cads as good dads.

    Science.gov (United States)

    Durante, Kristina M; Griskevicius, Vladas; Simpson, Jeffry A; Cantú, Stephanie M; Li, Norman P

    2012-08-01

    Why do some women pursue relationships with men who are attractive, dominant, and charming but who do not want to be in relationships--the prototypical sexy cad? Previous research shows that women have an increased desire for such men when they are ovulating, but it is unclear why ovulating women would think it is wise to pursue men who may be unfaithful and could desert them. Using both college-age and community-based samples, in 3 studies we show that ovulating women perceive charismatic and physically attractive men, but not reliable and nice men, as more committed partners and more devoted future fathers. Ovulating women perceive that sexy cads would be good fathers to their own children but not to the children of other women. This ovulatory-induced perceptual shift is driven by women who experienced early onset of puberty. Taken together, the current research identifies a novel proximate reason why ovulating women pursue relationships with sexy cads, complementing existing research that identifies the ultimate, evolutionary reasons for this behavior.

  3. Color change of CAD-CAM materials and composite resin cements after thermocycling.

    Science.gov (United States)

    Gürdal, Isil; Atay, Ayse; Eichberger, Marlis; Cal, Ebru; Üsümez, Aslihan; Stawarczyk, Bogna

    2018-04-24

    The color of resin cements and computer-aided-design and computer-aided-manufacturing (CAD-CAM) restorations may change with aging. The purpose of this in vitro study was to analyze the influence of thermocycling on the color of CAD-CAM materials with underlying resin cement. Seven different CAD-CAM materials, composite resins and glass-ceramics were cut into 0.7-mm and 1.2-mm thicknesses (n=10) and cemented with a dual-polymerizing resin cement, a light-polymerizing resin cement, and a preheated composite resin (N=420). Color values were measured by using spectrophotometry. Specimens were subjected to thermocycling (5°C and 55°C; 5000 cycles). The measured color difference (ΔE) data were analyzed by using descriptive statistics. Normality of data distribution was tested by using the Kolmogorov-Smirnov test. Three-way and 1-way ANOVA followed by the Scheffé post-hoc test and unpaired 2-sample Student t test were computed to determine the significant differences among the tested parameters (α=.05). ΔE values were significantly influenced by the CAD-CAM material (η p 2 =0.85, Pcement (η P 2 =0.03, P=.003) but were not influenced by thickness (P=.179). Significant interactions were present among thickness, cement, and CAD-CAM materials (Pcement showed significantly lower ΔE values than the preheated composite resin (P=.003). Restoration materials and composite resin cement types used for cementation influence the amount of color change due to aging. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Use, Attitudes and Knowledge of Complementary and Alternative Drugs (CADs among Pregnant Women: A Preliminary Survey in Tuscany

    Directory of Open Access Journals (Sweden)

    Francesco Lapi

    2010-01-01

    Full Text Available To explore pregnant women's use, attitudes, knowledge and beliefs of complementary and alternative drugs (CADs defined as products manufactured from herbs or with a natural origin. A preliminary survey was conducted among 172 pregnant women in their third trimester of pregnancy, consecutively recruited in two obstetrical settings; 15 women were randomly selected to compute a test-to-retest analysis. Response rate was 87.2%. Test-to-retest analysis showed a questionnaire's reproducibility exceeding a K-value of 0.7 for all items. Mean age was 32.4 ± 0.4 years; most women were nulliparae (62.7%. The majority of subjects (68% declared to have used one or more CADs during their lifetime; 48% of pregnant women reported taking at least one CAD previously and during the current pregnancy. Women's habitual use of CADs meant they were at higher risk of taking CADs also during pregnancy (adjusted odds ratio = 10.8; 95% confidence interval: 4.7–25.0. Moreover, 59.1% of the subjects were unable to correctly identify the type of CADs they were using. The majority of women resorted to gynecologists as the primary information source for CADs during pregnancy, while they mainly referred to herbalists when not pregnant. Habitual use of CADs seems to be a strong predictor for their ingestion also during pregnancy; in addition most subjects were unable to correctly identify the products they were taking. In the light of the scanty data concerning the safety of CADs during pregnancy, these preliminary results confirm the need to investigate thoroughly the situation of pregnant women and CADs consumption.

  5. A simple web-based tool to compare freshwater fish data collected using AFS standard methods

    Science.gov (United States)

    Bonar, Scott A.; Mercado-Silva, Norman; Rahr, Matt; Torrey, Yuta T.; Cate, Averill

    2016-01-01

    The American Fisheries Society (AFS) recently published Standard Methods for Sampling North American Freshwater Fishes. Enlisting the expertise of 284 scientists from 107 organizations throughout Canada, Mexico, and the United States, this text was developed to facilitate comparisons of fish data across regions or time. Here we describe a user-friendly web tool that automates among-sample comparisons in individual fish condition, population length-frequency distributions, and catch per unit effort (CPUE) data collected using AFS standard methods. Currently, the web tool (1) provides instantaneous summaries of almost 4,000 data sets of condition, length frequency, and CPUE of common freshwater fishes collected using standard gears in 43 states and provinces; (2) is easily appended with new standardized field data to update subsequent queries and summaries; (3) compares fish data from a particular water body with continent, ecoregion, and state data summaries; and (4) provides additional information about AFS standard fish sampling including benefits, ongoing validation studies, and opportunities to comment on specific methods. The web tool—programmed in a PHP-based Drupal framework—was supported by several AFS Sections, agencies, and universities and is freely available from the AFS website and fisheriesstandardsampling.org. With widespread use, the online tool could become an important resource for fisheries biologists.

  6. Stock Versus CAD/CAM Customized Zirconia Implant Abutments – Clinical and Patient‐Based Outcomes in a Randomized Controlled Clinical Trial

    Science.gov (United States)

    Meijer, Henny J.A.; Kerdijk, Wouter; Raghoebar, Gerry M.; Cune, Marco

    2016-01-01

    Abstract Background Single‐tooth replacement often requires a prefabricated dental implant and a customized crown. The benefits of individualization of the abutment remain unclear. Purpose This randomized controlled clinical trial aims to study potential benefits of individualization of zirconia implant abutments with respect to preservation of marginal bone level and several clinical and patient‐based outcome measures. Material and Methods Fifty participants with a missing premolar were included and randomly assigned to standard (ZirDesign, DentsplySirona Implants, Mölndal, Sweden) or computer aided design/computer aided manufacturing (CAD/CAM) customized (Atlantis, DentsplySirona Implants, Mölndal, Sweden) zirconia abutment therapy. Peri‐implant bone level (primary outcome), Plaque‐index, calculus formation, bleeding on probing, gingiva index, probing pocket depth, recession, appearance of soft tissues and patients' contentment were assessed shortly after placement and one year later. Results No implants were lost and no complications related to the abutments were observed. Statistically significant differences between stock and CAD/CAM customized zirconia abutments could not be demonstrated for any of the operationalized variables. Conclusion The use of a CAD/CAM customized zirconia abutment in single tooth replacement of a premolar is not associated with an improvement in clinical performance or patients' contentment when compared to the use of a stock zirconia abutment. PMID:27476829

  7. CAD-CAE in Electrical Machines and Drives Teaching.

    Science.gov (United States)

    Belmans, R.; Geysen, W.

    1988-01-01

    Describes the use of computer-aided design (CAD) techniques in teaching the design of electrical motors. Approaches described include three technical viewpoints, such as electromagnetics, thermal, and mechanical aspects. Provides three diagrams, a table, and conclusions. (YP)

  8. Understanding dental CAD/CAM for restorations--the digital workflow from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P

    2015-01-01

    As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology.

  9. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement.

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin; Tulga, Ayça

    2017-12-01

    To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) ( P CAD/CAM restorative materials was modified after treatments. The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials.

  10. Clinical monitoring of tooth wear progression in patients over a period of one year using CAD/CAM

    OpenAIRE

    Ahmed, Khaled E.; Whitters, John; Ju, Xiangyang; Pierce, S. Gareth; MacLeod, Charles N.; Murray, Colin A.

    2017-01-01

    Purpose: The aim of this study was to clinically monitor the progression of tooth wear over a period of 1 year in a cohort of referred tooth wear patients through the use of a computer-aided design/ computer-assisted manufacture (CAD/CAM) scanner and a standardized scanning/assessment methodology. Materials and Methods: Polyether impressions were made of 11 participants (130 teeth) at baseline and at 1 year. Impressions were poured in type IV dental stone and the anterior teeth were 3D scanne...

  11. APPLICATION OF 3D DIGITAL SCANNING AND CAD/CAM SYSTEMS FOR ZIRCONIA INDIRECT RESTORATIONS

    Directory of Open Access Journals (Sweden)

    Mariela Tsanova

    2016-09-01

    Full Text Available Object: To study the CAD/CAM systems’ possibilities for manufacturing Zirconia indirect restorations for restoring vital, vastly devastated teeth. Material and methods: Five patients with vital, heavily destroyed molars were included in the clinical study. The teeth were prepared according to requirements for Zirconia restorations. The impressions were taken with 3D intraoral scanner. The acquired data is transmitted electronically for designing the future restoration by the CAD software. After designing, the restoration is milled by the CAM module and sintered, according to a specially projected programme in accordance with the manufacturing demands. After clinical check-up, the restorations are glazed, air-blasted and cemented. Results: Setting up an individual protocol for working with CAD/CAM systems for restoring vital, severely devastated teeth with Zirconia indirect restorations. A research is made on 3D digital scanning, occlusal and proximal modeling, virtual articulation, analyzing the incline of the cavity walls, the thickness of the restoration and the possibilities for restoring the anatomy of the tooth according to patient’s individual characteristics of the teeth’s arch. Conclusion: The scanning and design process should be evaluated with the same quality control as when using traditional methods. The CAD software requires excellent preparation of the tooth cavity and digital scanning. This is the reason why these systems require a thorough understanding of CAD/CAM calibration and parameters of the product to be clinically acceptable. Once understood, CAD/CAM dentistry can create detailed and accurate restorations that function and perform with great success and longevity.

  12. TNF-alpha-308G>A polymorphism and the risk of familial CAD in a Pakistani population.

    Science.gov (United States)

    Hussain, Sabir; Iqbal, Tahir; Javed, Qamar

    2015-01-01

    A case-control and trio-families study was performed to establish a potential association between TNF-alpha gene promoter SNPs at -308 and -238, and occurrence of CAD in a Pakistani population. In the first phase, 150 patients and 150 controls were enrolled in the case-control association study. In the second phase, heritability of susceptible alleles was investigated from 88 trio-families with CAD affected offspring. Biochemical analysis of lipids and hs-CRP was carried out spectrophotometrically, while serum TNF-alpha concentrations were determined by enzyme-linked immunosorbent assay. Genotyping of the TNF-alpha SNPs were determined by PCR-RFLP method. Elevated serum TNF-alpha and hs-CRP were observed from CAD vs. controls (PA polymorphism in case-control study revealed that the said SNP was significantly associated with the increased risk of CAD. The findings demonstrated a significant link between the TNF-alpha variant allele A at -308 and CAD (P=0.0035), whereas the -238 SNP was not associated with the disease. Haplotype A-G of the TNF-alpha gene at -308G>A and -238G>A showed higher frequency in the patient group compared with controls (PA polymorphism is associated with CAD in the study population. Furthermore, for the first time, we showed that the TNF-alpha-308A allele was significantly associated with the familial CAD in our high risk population. Copyright © 2014. Published by Elsevier Inc.

  13. Gaps Analysis of Integrating Product Design, Manufacturing, and Quality Data in The Supply Chain Using Model-Based Definition.

    Science.gov (United States)

    Trainer, Asa; Hedberg, Thomas; Feeney, Allison Barnard; Fischer, Kevin; Rosche, Phil

    2016-01-01

    Advances in information technology triggered a digital revolution that holds promise of reduced costs, improved productivity, and higher quality. To ride this wave of innovation, manufacturing enterprises are changing how product definitions are communicated - from paper to models. To achieve industry's vision of the Model-Based Enterprise (MBE), the MBE strategy must include model-based data interoperability from design to manufacturing and quality in the supply chain. The Model-Based Definition (MBD) is created by the original equipment manufacturer (OEM) using Computer-Aided Design (CAD) tools. This information is then shared with the supplier so that they can manufacture and inspect the physical parts. Today, suppliers predominantly use Computer-Aided Manufacturing (CAM) and Coordinate Measuring Machine (CMM) models for these tasks. Traditionally, the OEM has provided design data to the supplier in the form of two-dimensional (2D) drawings, but may also include a three-dimensional (3D)-shape-geometry model, often in a standards-based format such as ISO 10303-203:2011 (STEP AP203). The supplier then creates the respective CAM and CMM models and machine programs to produce and inspect the parts. In the MBE vision for model-based data exchange, the CAD model must include product-and-manufacturing information (PMI) in addition to the shape geometry. Today's CAD tools can generate models with embedded PMI. And, with the emergence of STEP AP242, a standards-based model with embedded PMI can now be shared downstream. The on-going research detailed in this paper seeks to investigate three concepts. First, that the ability to utilize a STEP AP242 model with embedded PMI for CAD-to-CAM and CAD-to-CMM data exchange is possible and valuable to the overall goal of a more efficient process. Second, the research identifies gaps in tools, standards, and processes that inhibit industry's ability to cost-effectively achieve model-based-data interoperability in the pursuit of the

  14. Hybrid tooling technologies and standardization for the manufacturing of inserts for micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Fillon, Bertrand; Azcarate, Sabino

    2007-01-01

    This paper is based on the European Platform’s activities within the 4M Network of Excellence “Multi-Material Micro Manufacturing”. To overpass limitations of the current existing micro tooling capabilities, a new generation of micro hybrid tooling technologies for micro replication was developed....... A metrological approach was applied to standardize the employed tooling processes (micro milling, µEDM, laser micromachining, electrochemical µ-milling). The micro tools were then tested with different polymers (PP, PP + nano fillers, PC, COC). The paper provides a comparison of these technologies concerning...

  15. Combined photogrammetry and 3-D CAD for plant documentation and planning of refits

    International Nuclear Information System (INIS)

    Fraas, K.C.; Giese, U.; Kamsties, K.D.

    1991-01-01

    Meticulous advance planning and erection studies using a three-dimensional computer-aided design model of the plant area concerned can reduce the problem that unexpected events during a plant refit will prolong the required inspection period. This presupposes that a 3-D CAD scale model of the running plant has been generated. A method is described with which the as-built condition of the plant area is converted into a 3-D CAD model by combining photogrammetry with 3-D CAD. The minimum amount of time required for in-plant surveying and the completeness and clarity of results are the special advantages of this method in comparison with other measurement techniques. Selected applications are presented. (orig.) [de

  16. Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview

    Directory of Open Access Journals (Sweden)

    Chui Ling Goo

    2017-01-01

    Full Text Available This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.

  17. Evaluation of the specificity of radionuclide myocardial imaging for detecting CAD

    International Nuclear Information System (INIS)

    Liu Xiujie

    1992-01-01

    In order to evaluate the specificity of radionuclide myocardial perfusion imaging for detecting coronary artery disease (CAD), 50 patients with normal coronary arteriography and radionuclide myocardial perfusion scintigraphy were analysed. The results from 201 T1 (20 cases) and 99m Tc-MIBI (30 cases) studies showed that out of 33 patients with no organic cardiovascular disease, 29 had normal myocardial imaging, and the specificity of radionuclide myocardial imaging for detecting CAD was 87.8%. 4 normal young women had false positive myocardial imaging. Out of 17 patients with cardiovascular disease and normal coronary arteriography, 15 patients had abnormal myocardial imaging. The final clinical diagnoses of these 15 patients were: 4 patients with hypertrophic cardiomyopathy, 3 with old myocardial infarction, 2 with myocarditis, 3 with small coronary vessel disease, 1 with congestive cardiomyopathy, and 2 with other cardiac disorder. The points of differentiation between CAD and other cardiovascular disease using radionuclide techniques were discussed

  18. The Role of CAD in Enterprise Integration Process

    Directory of Open Access Journals (Sweden)

    M. Ota

    2004-01-01

    Full Text Available This article deals with the problem of the mutual influence between software systems used in enterprise environment and enterprise integration processes. The position of CAD data and CAx systems in the integrated environment of manufacturing enterprises is clarified. As a consequence, the key role of CAx systems used in those companies is emphasized. It is noted that the integration of CAD data is nowadays only on a secondary level, via primarily integrated PDM systems. This limitation is a reason why we are developing a unified communication model focused on product-oriented data. Our approach is based on Internet technologies, so we believe that is independent enough. The proposed system of communication is based on a simple request-replay dialogue. The structure of this model is open and extensible, but we assume supervision supported by an Internet portal.

  19. Kinematic optimization of upgrade to the Hobby-Eberly Telescope through novel use of commercially available three-dimensional CAD package

    Science.gov (United States)

    Wedeking, Gregory A.; Zierer, Joseph J.; Jackson, John R.

    2010-07-01

    The University of Texas, Center for Electromechanics (UT-CEM) is making a major upgrade to the robotic tracking system on the Hobby Eberly Telescope (HET) as part of theWide Field Upgrade (WFU). The upgrade focuses on a seven-fold increase in payload and necessitated a complete redesign of all tracker supporting structure and motion control systems, including the tracker bridge, ten drive systems, carriage frames, a hexapod, and many other subsystems. The cost and sensitivity of the scientific payload, coupled with the tracker system mass increase, necessitated major upgrades to personnel and hardware safety systems. To optimize kinematic design of the entire tracker, UT-CEM developed novel uses of constraints and drivers to interface with a commercially available CAD package (SolidWorks). For example, to optimize volume usage and minimize obscuration, the CAD software was exercised to accurately determine tracker/hexapod operational space needed to meet science requirements. To verify hexapod controller models, actuator travel requirements were graphically measured and compared to well defined equations of motion for Stewart platforms. To ensure critical hardware safety during various failure modes, UT-CEM engineers developed Visual Basic drivers to interface with the CAD software and quickly tabulate distance measurements between critical pieces of optical hardware and adjacent components for thousands of possible hexapod configurations. These advances and techniques, applicable to any challenging robotic system design, are documented and describe new ways to use commercially available software tools to more clearly define hardware requirements and help insure safe operation.

  20. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin

    2017-01-01

    PURPOSE To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. MATERIALS AND METHODS The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. RESULTS The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) (Pcementation of the novel CAD/CAM restorative materials. PMID:29279763

  1. ELM BASED CAD SYSTEM TO CLASSIFY MAMMOGRAMS BY THE COMBINATION OF CLBP AND CONTOURLET

    Directory of Open Access Journals (Sweden)

    S Venkatalakshmi

    2017-05-01

    Full Text Available Breast cancer is a serious life threat to the womanhood, worldwide. Mammography is the promising screening tool, which can show the abnormality being detected. However, the physicians find it difficult to detect the affected regions, as the size of microcalcifications is very small. Hence it would be better, if a CAD system can accompany the physician in detecting the malicious regions. Taking this as a challenge, this paper presents a CAD system for mammogram classification which is proven to be accurate and reliable. The entire work is decomposed into four different stages and the outcome of a phase is passed as the input of the following phase. Initially, the mammogram is pre-processed by adaptive median filter and the segmentation is done by GHFCM. The features are extracted by combining the texture feature descriptors Completed Local Binary Pattern (CLBP and contourlet to frame the feature sets. In the training phase, Extreme Learning Machine (ELM is trained with the feature sets. During the testing phase, the ELM can classify between normal, malignant and benign type of cancer. The performance of the proposed approach is analysed by varying the classifier, feature extractors and parameters of the feature extractor. From the experimental analysis, it is evident that the proposed work outperforms the analogous techniques in terms of accuracy, sensitivity and specificity.

  2. TU-G-204-09: The Effects of Reduced- Dose Lung Cancer Screening CT On Lung Nodule Detection Using a CAD Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Young, S; Lo, P; Kim, G; Hsu, W; Hoffman, J; Brown, M; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2015-06-15

    Purpose: While Lung Cancer Screening CT is being performed at low doses, the purpose of this study was to investigate the effects of further reducing dose on the performance of a CAD nodule-detection algorithm. Methods: We selected 50 cases from our local database of National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data from the original scans. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. 10 of the cases had at least one nodule reported on the NLST reader forms. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, the CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST reports. Subject-level mean sensitivities and false-positive rates were calculated for each dose level. Results: The mean sensitivities of the CAD algorithm were 35% at the original dose, 20% at 50% dose, and 42.5% at 25% dose. The false-positive rates, in decreasing-dose order, were 3.7, 2.9, and 10 per case. In certain cases, particularly in larger patients, there were severe photon-starvation artifacts, especially in the apical region due to the high-attenuating shoulders. Conclusion: The detection task was challenging for the CAD algorithm at all dose levels, including the original NLST dose. However, the false-positive rate at 25% dose approximately tripled, suggesting a loss of CAD robustness somewhere between 0.5 and 1.0 mGy. NCI grant U01 CA181156 (Quantitative Imaging Network); Tobacco Related Disease Research Project grant 22RT-0131.

  3. TU-G-204-09: The Effects of Reduced- Dose Lung Cancer Screening CT On Lung Nodule Detection Using a CAD Algorithm

    International Nuclear Information System (INIS)

    Young, S; Lo, P; Kim, G; Hsu, W; Hoffman, J; Brown, M; McNitt-Gray, M

    2015-01-01

    Purpose: While Lung Cancer Screening CT is being performed at low doses, the purpose of this study was to investigate the effects of further reducing dose on the performance of a CAD nodule-detection algorithm. Methods: We selected 50 cases from our local database of National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data from the original scans. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. 10 of the cases had at least one nodule reported on the NLST reader forms. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, the CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST reports. Subject-level mean sensitivities and false-positive rates were calculated for each dose level. Results: The mean sensitivities of the CAD algorithm were 35% at the original dose, 20% at 50% dose, and 42.5% at 25% dose. The false-positive rates, in decreasing-dose order, were 3.7, 2.9, and 10 per case. In certain cases, particularly in larger patients, there were severe photon-starvation artifacts, especially in the apical region due to the high-attenuating shoulders. Conclusion: The detection task was challenging for the CAD algorithm at all dose levels, including the original NLST dose. However, the false-positive rate at 25% dose approximately tripled, suggesting a loss of CAD robustness somewhere between 0.5 and 1.0 mGy. NCI grant U01 CA181156 (Quantitative Imaging Network); Tobacco Related Disease Research Project grant 22RT-0131

  4. Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader

    International Nuclear Information System (INIS)

    Beyer, F.; Zierott, L.; Juergens, K.U.; Heindel, W.; Fallenberg, E.M.; Stoeckel, J.; Wormanns, D.

    2007-01-01

    The purpose of this study was to compare sensitivity for detection of pulmonary nodules in MDCT scans and reading time of radiologists when using CAD as the second reader (SR) respectively concurrent reader (CR). Four radiologists analyzed 50 chest MDCT scans chosen from clinical routine two times and marked all detected pulmonary nodules: first with CAD as CR (display of CAD results immediately in the reading session) and later (median 14 weeks) with CAD as SR (display of CAD markers after completion of first reading without CAD). A Siemens LungCAD prototype was used. Sensitivities for detection of nodules and reading times were recorded. Sensitivity of reading with CAD as SR was significantly higher than reading without CAD (p < 0.001) and CAD as CR (p < 0.001). For nodule size of 1.75 mm or above no significant sensitivity difference between CAD as CR and reading without CAD was observed; e.g., for nodules above 4 mm sensitivity was 68% without CAD, 68% with CAD as CR (p 0.45) and 75% with CAD as SR (p < 0.001). Reading time was significantly shorter for CR (274 s) compared to reading without CAD (294 s; p = 0.04) and SR (337 s; p < 0.001). In our study CAD could either speed up reading of chest CT cases for pulmonary nodules without relevant loss of sensitivity when used as CR, or it increased sensitivity at the cost of longer reading times when used as SR. (orig.)

  5. Colour parameters and shade correspondence of CAD-CAM ceramic systems.

    Science.gov (United States)

    Della Bona, Alvaro; Pecho, Oscar E; Ghinea, Razvan; Cardona, Juan C; Pérez, María M

    2015-06-01

    To evaluate colour differences between (1) CAD-CAM ceramic systems considering shades A1, A2 and A3 and the corresponding nominal shade of VC (Vita Classical shade guide) and (2) shades A1-A2, A2-A3 and A1, A2 and A3 within the same ceramic system. Samples of shades A1, A2 and A3 were fabricated (n=5) from CAD-CAM ceramic blocks (IPS e.max(®) CAD LT and HT, IPS Empress(®) CAD LT and HT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. Spectral reflectance and colour coordinates were measured using a spectroradiometer inside a viewing booth using the CIE D65 illuminant and the d/0° geometry. Spectral reflectance curves were compared using VAF coefficient and were statistically analyzed using Kruskal-Wallis and the Mann-Whitney U test (α=0.05). Colour coordinates were statistically analyzed using one-way ANOVA, Tukey's test with Bonferroni correction (α=0.001). All colour differences (ΔEab(*) and ΔE00) were analyzed through comparisons with the PT - perceptibility and AT - acceptability thresholds for dental ceramics. ΔE between ceramic systems and its corresponding shade ranged from 6.32 to 13.42 (ΔEab(*)) and 4.48 to 9.30 (ΔE00). ΔE between shades A1-A2, A2-A3 and A1, A2 and A3 ranged, respectively, 1.93-4.82, 1.22-5.59 and 3.63-8.84 (ΔEab(*)); 1.54-3.87, 1.03-3.90 and 2.95-6.51 (ΔE00). Considering the corresponding nominal shade from VC, none of the ceramic systems showed colour differences below the AT. In addition, some ceramic systems showed colour differences below AT (shades A1-A2 and A2-A3) and below PT (shades A2-A3). Careful adjustments should be made to the final shade of CAD-CAM ceramic restorations to reach a clinically acceptable shade match. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. El CAD en la actividad de reingeniería e ingeniería en los mantenimientos a centrales eléctricas // CAD in the reengineering and engineering activity in maintenance of power plants

    Directory of Open Access Journals (Sweden)

    R. García Ramírez

    2000-07-01

    Full Text Available El presente trabajo muestra algunas experiencias obtenidas en la actividad de ingeniería y reingeniería durante elmantenimiento a centrales eléctricas con empleo del CAD (Computer Aided Design, se muestran además las estrategiasseguidas con vistas a automatizar la actividad de reingeniería en ordenadores y a lograr mejoras económicas en la actividada costa de disminuir los costos de producción.Palabras claves: CAD, reingeniería, mantenimiento de calderas._________________________________________________________________________AbstractThe present work shows some experiences obtained in the engineering and reengineering during the maintenance activity inpower plants carried out by our company applying the CAD (Computer Aided Design, it is also exposed the strategyfollowed with a view to automating the reengineering activity with the use of computers, keeping in mind a view to achieveconomic improvements in the activity to diminish production costs.Key words: reengineering, CAD, maintenance, boiler.

  7. Evolution of facility layout requirements and CAD [computer-aided design] system development

    International Nuclear Information System (INIS)

    Jones, M.

    1990-06-01

    The overall configuration of the Superconducting Super Collider (SSC) including the infrastructure and land boundary requirements were developed using a computer-aided design (CAD) system. The evolution of the facility layout requirements and the use of the CAD system are discussed. The emphasis has been on minimizing the amount of input required and maximizing the speed by which the output may be obtained. The computer system used to store the data is also described

  8. CADS: a FORTRAN subroutine package to aid symbolic dataflow in FORTRAN programs

    International Nuclear Information System (INIS)

    Richards, L.R.P.; Butland, A.T.D.; Symonds, A.G.

    1982-07-01

    The Core Allocation and Dataflow System, CADS, consists of two parts, VARY and VARYIO. VARY provides a means of organising the use of data store in a program by allowing the programmer to reference and manipulate areas of data store by names of the programmer's subprogram, and therefore the complete program, to be independent of its data sources or the destination of its results. CADS therefore provides a system of symbolic dataflow. (author)

  9. WEBSITE EXECUTION OF CAD MODULES

    Directory of Open Access Journals (Sweden)

    A. A. Lyalinsky

    2013-01-01

    Full Text Available Web-based interface of modules that are part of the computer-aided design system in microelectronics is considered. The influence of several factors (available computer  memory, maximum allowed run time, degree of homogeneity of the software on the structure of the created system is investigated. Synchronous and asynchronous variants of interaction between control and executive parts are described. References on the systems that allow an access to applications in CAD microelectronics and are based on the principles discussed in this article are given.

  10. Multi-site evaluation of a computer aided detection (CAD) algorithm for small acute intra-cranial hemorrhage and development of a stand-alone CAD system ready for deployment in a clinical environment

    Science.gov (United States)

    Deshpande, Ruchi R.; Fernandez, James; Lee, Joon K.; Chan, Tao; Liu, Brent J.; Huang, H. K.

    2010-03-01

    Timely detection of Acute Intra-cranial Hemorrhage (AIH) in an emergency environment is essential for the triage of patients suffering from Traumatic Brain Injury. Moreover, the small size of lesions and lack of experience on the reader's part could lead to difficulties in the detection of AIH. A CT based CAD algorithm for the detection of AIH has been developed in order to improve upon the current standard of identification and treatment of AIH. A retrospective analysis of the algorithm has already been carried out with 135 AIH CT studies with 135 matched normal head CT studies from the Los Angeles County General Hospital/ University of Southern California Hospital System (LAC/USC). In the next step, AIH studies have been collected from Walter Reed Army Medical Center, and are currently being processed using the AIH CAD system as part of implementing a multi-site assessment and evaluation of the performance of the algorithm. The sensitivity and specificity numbers from the Walter Reed study will be compared with the numbers from the LAC/USC study to determine if there are differences in the presentation and detection due to the difference in the nature of trauma between the two sites. Simultaneously, a stand-alone system with a user friendly GUI has been developed to facilitate implementation in a clinical setting.

  11. The effect of glazing and aging on the surface properties of CAD/CAM resin blocks.

    Science.gov (United States)

    Tekçe, Neslihan; Fidan, Sinan; Tuncer, Safa; Kara, Dilan; Demirci, Mustafa

    2018-02-01

    To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad Säckingen, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1: control group (specimens polished with 600 grit SCI paper); Group 2: specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3: glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness (R a and R z ) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post-hoc test ( P .05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher R a values than Group 2 ( P .05). Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles.

  12. Creation of minimum standard tool for palliative care in India and self-evaluation of palliative care programs using it

    Directory of Open Access Journals (Sweden)

    M R Rajagopal

    2014-01-01

    Full Text Available Background: It is important to ensure that minimum standards for palliative care based on available resources are clearly defined and achieved. Aims: (1 Creation of minimum National Standards for Palliative Care for India. (2 Development of a tool for self-evaluation of palliative care organizations. (3 Evaluation of the tool in India. In 2006, Pallium India assembled a working group at the national level to develop minimum standards. The standards were to be evaluated by palliative care services in the country. Materials and Methods: The working group prepared a "standards" document, which had two parts - the first composed of eight "essential" components and the second, 22 "desirable" components. The working group sent the document to 86 hospice and palliative care providers nationwide, requesting them to self-evaluate their palliative care services based on the standards document, on a modified Likert scale. Results: Forty-nine (57% palliative care organizations responded, and their self-evaluation of services based on the standards tool was analyzed. The majority of the palliative care providers met most of the standards identified as essential by the working group. A variable percentage of organizations had satisfied the desirable components of the standards. Conclusions: We demonstrated that the "standards tool" could be applied effectively in practice for self-evaluation of quality of palliative care services.

  13. A CAD model for energy efficient offshore structures for desalination and energy generation

    Directory of Open Access Journals (Sweden)

    R. Rahul Dev,

    2016-09-01

    Full Text Available This paper presents a ‘Computer Aided Design (CAD’ model for energy efficient design of offshore structures. In the CAD model preliminary dimensions and geometric details of an offshore structure (i.e. semi-submersible are optimized to achieve a favorable range of motion to reduce the energy consumed by the ‘Dynamic Position System (DPS’. The presented model allows the designer to select the configuration satisfying the user requirements and integration of Computer Aided Design (CAD and Computational Fluid Dynamics (CFD. The integration of CAD with CFD computes a hydrodynamically and energy efficient hull form. Our results show that the implementation of the present model results into an design that can serve the user specified requirements with less cost and energy consumption.

  14. On CAD-integrated Structural Topology and Design Optimization

    DEFF Research Database (Denmark)

    Olhoff, Niels; Bendsøe, M.P.; Rasmussen, John

    1991-01-01

    Concepts underlying an interactive CAD-based engineering design optimization system are developed, and methods of optimizing the topology, shape and sizing of mechanical components are presented. These methods are integrated in the system, and the method for determining the optimal topology is used...

  15. Sustainable development induction in organizations: a convergence analysis of ISO standards management tools' parameters.

    Science.gov (United States)

    Merlin, Fabrício Kurman; Pereira, Vera Lúciaduarte do Valle; Pacheco, Waldemar

    2012-01-01

    Organizations are part of an environment in which they are pressured to meet society's demands and acting in a sustainable way. In an attempt to meet such demands, organizations make use of various management tools, among which, ISO standards are used. Although there are evidences of contributions provided by these standards, it is questionable whether its parameters converge for a possible induction for sustainable development in organizations. This work presents a theoretical study, designed on structuralism world view, descriptive and deductive method, which aims to analyze the convergence of management tools' parameters in ISO standards. In order to support the analysis, a generic framework for possible convergence was developed, based on systems approach, linking five ISO standards (ISO 9001, ISO 14001, OHSAS 18001, ISO 31000 and ISO 26000) with sustainable development and positioning them according to organization levels (strategic, tactical and operational). The structure was designed based on Brundtland report concept. The analysis was performed exploring the generic framework for possible convergence based on Nadler and Tushman model. The results found the standards can contribute to a possible sustainable development induction in organizations, as long as they meet certain minimum conditions related to its strategic alignment.

  16. Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results.

    Science.gov (United States)

    Cooper, Lyndon F; Stanford, Clark; Feine, Jocelyne; McGuire, Michael

    2016-07-01

    Single-tooth implant restorations are commonly used to replace anterior maxillary teeth. The esthetic, functional, and biologic outcomes are, in part, a function of the abutment and crown. The purpose of this clinical study was to describe the implant, abutment, and crown survival and complication rates for CAD/CAM zirconia abutment and lithium disilicate crown restorations for single-tooth implants. As part of a broader prospective investigation that enrolled and treated 141 participants comparing tissue responses at the conical interface (CI; AstraTech OsseoSpeed), flat-to-flat interface (FI; NobelSpeedy), and platform-switch interface (PS; NanoTite Certain Prevail) of single-tooth implants, computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia abutments (ATLANTIS Abutment) and cemented lithium disilicate (e.max) crowns were used in the restoration of all implants. After 2.4 years in function (3 years after implant placement), the implant, abutment, and crown of 110 participants were evaluated. Technical and biologic complications were recorded. Demographic results were tabulated as percentages with mean values and standard deviations. Abutment survival was calculated with the Kaplan-Meier method. After 2.4 years, no abutments or crowns had been lost. Abutment complications (screw loosening, screw fracture, fracture) were absent for all 3 implant groups. Crown complications were limited to 2 crowns debonding and 1 with excess cement (2.5%). Five biological complications (4.0%) were recorded. The overall complication rate was 6.5%. CAD/CAM zirconia abutments restored with cemented lithium disilicate crowns demonstrated high survival on 3 different implant-abutment interface designs. No abutment or abutment screw fracture occurred. The technical complications observed after 2.4 years were minor and reversible. The use of CAD/CAM zirconia abutments with cemented lithium disilicate crowns is associated with high technical and biologic success at 2

  17. The value of radionuclide phase analysis and parameters of cardial function for diagnosis CAD at rest and during exercise

    International Nuclear Information System (INIS)

    Huang Gang

    1990-01-01

    27 patients and 5 normal were studied with ECG-gated cardial blood pool images and radionuclide phase analysis at rest and during exercise. The results showed that the sensitivity of LVEF in CAD at rest and during exercise were 57% and 71% respectively, and the sensitivity of the ventricular phase in CAD were 79% at rest and 90% during exercise, and the sensitivity of phase angle in CAD were higher than of LVEF. This suggested that the ventricular phase angle was important for diagnosing early CAD. In addition, regional EF, phase image and ventricular wall motion were useful to detect the lesion of ischemia in CAD

  18. Integrated electric circuit CAD system in Minolta Camera Co. Ltd

    Energy Technology Data Exchange (ETDEWEB)

    Nakagami, Tsuyoshi; Hirata, Sumiaki; Matsumura, Fumihiko

    1988-08-26

    Development background, fundamental concept, details and future plan of the integrated electric circuit CAD system for OA equipment are presented. The central integrated database is basically intended to store experiences or know-hows, to cover the wide range of data required for designs, and to provide a friendly interface. This easy-to-use integrated database covers the drawing data, parts information, design standards, know-hows and system data. The system contains the circuit design function to support drawing circuit diagrams, the wiring design function to support the wiring and arrangement of printed circuit boards and various parts integratedly, and the function to verify designs, to make full use of parts or technical information, to maintain the system security. In the future, as the system will be wholly in operation, the design period reduction, quality improvement and cost saving will be attained by this integrated design system. (19 figs, 2 tabs)

  19. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    Science.gov (United States)

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  20. A Knowledge Based Approach to VLSI CAD

    Science.gov (United States)

    1983-09-01

    Avail-and/or Dist ISpecial L| OI. SEICURITY CLASIIrCATION OP THIS IPA.lErllm S Daene." A KNOwLEDE BASED APPROACH TO VLSI CAD’ Louis L Steinberg and...major issues lies in building up and managing the knowledge base of oesign expertise. We expect that, as with many recent expert systems, in order to

  1. A Multidisciplinary Research Team Approach to Computer-Aided Drafting (CAD) System Selection. Final Report.

    Science.gov (United States)

    Franken, Ken; And Others

    A multidisciplinary research team was assembled to review existing computer-aided drafting (CAD) systems for the purpose of enabling staff in the Design Drafting Department at Linn Technical College (Missouri) to select the best system out of the many CAD systems in existence. During the initial stage of the evaluation project, researchers…

  2. The Use of a Parametric Feature Based CAD System to Teach Introductory Engineering Graphics.

    Science.gov (United States)

    Howell, Steven K.

    1995-01-01

    Describes the use of a parametric-feature-based computer-aided design (CAD) System, AutoCAD Designer, in teaching concepts of three dimensional geometrical modeling and design. Allows engineering graphics to go beyond the role of documentation and communication and allows an engineer to actually build a virtual prototype of a design idea and…

  3. The building and application of a flexible CAD model for the DTU ECOCAR

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg

    A flexible surface model is required for CFD-optimization of the DTU ECOCAR. The report exemplifies the creation of such a model using the 3D CAD system Creo 3.0 Parametric.......A flexible surface model is required for CFD-optimization of the DTU ECOCAR. The report exemplifies the creation of such a model using the 3D CAD system Creo 3.0 Parametric....

  4. Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study.

    Science.gov (United States)

    Sonmez, Nesrin; Gultekin, Pinar; Turp, Volkan; Akgungor, Gokhan; Sen, Deniz; Mijiritsky, Eitan

    2018-01-08

    Polymer infiltrated ceramics and nano-ceramic resins are the new restorative materials which have been developed in order to enhance the adverse properties of glass-matrix ceramics and resin composites. The aim of the present in vitro study was to evaluate the characteristics of various CAD/CAM materials through mechanical, microstructural, and SEM analysis. Five test groups (n = 22) were formed by using the indicated CAD/CAM blocks: VITA Enamic (VITA Zahnfabrik), Lava Ultimate (3 M ESPE), IPS e.max CAD (Ivoclar Vivadent), IPS Empress CAD (Ivoclar Vivadent), and VITA Mark II (VITA Zahnfabrik). Two specimens from each test group were used for XRD and EDS analysis. Remaining samples were divided into two subgroups (n = 10). One subgroup specimens were thermocycled (5 °C to 55 °C, 30s, 10,000 cycles) whereas the other were not. All of the specimens were evaluated in terms of flexural strength, Vickers hardness, and fracture toughness. Results were statistically analyzed using two-way ANOVA, one-way ANOVA, Tukey's HSD, and Student's t tests (α = .05). Fractured specimens were evaluated using SEM. The highest Vickers microhardness value was found for VITA Mark II (p CAD was found to have the highest flexural strength (p CAD was also higher than other tested block materials (p CAD groups. It should be realised that simulated aging process seem to affect ceramic-polymer composite materials more significantly than glass ceramics.

  5. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Randomized controlled within-subject evaluation of digital and conventional workflows for the fabrication of lithium disilicate single crowns. Part II: CAD-CAM versus conventional laboratory procedures.

    Science.gov (United States)

    Sailer, Irena; Benic, Goran I; Fehmer, Vincent; Hämmerle, Christoph H F; Mühlemann, Sven

    2017-07-01

    Clinical studies are needed to evaluate the entire digital and conventional workflows in prosthetic dentistry. The purpose of the second part of this clinical study was to compare the laboratory production time for tooth-supported single crowns made with 4 different digital workflows and 1 conventional workflow and to compare these crowns clinically. For each of 10 participants, a monolithic crown was fabricated in lithium disilicate-reinforced glass ceramic (IPS e.max CAD). The computer-aided design and computer-aided manufacturing (CAD-CAM) systems were Lava C.O.S. CAD software and centralized CAM (group L), Cares CAD software and centralized CAM (group iT), Cerec Connect CAD software and lab side CAM (group CiL), and Cerec Connect CAD software with centralized CAM (group CiD). The conventional fabrication (group K) included a wax pattern of the crown and heat pressing according to the lost-wax technique (IPS e.max Press). The time for the fabrication of the casts and the crowns was recorded. Subsequently, the crowns were clinically evaluated and the corresponding treatment times were recorded. The Paired Wilcoxon test with the Bonferroni correction was applied to detect differences among treatment groups (α=.05). The total mean (±standard deviation) active working time for the dental technician was 88 ±6 minutes in group L, 74 ±12 minutes in group iT, 74 ±5 minutes in group CiL, 92 ±8 minutes in group CiD, and 148 ±11 minutes in group K. The dental technician spent significantly more working time for the conventional workflow than for the digital workflows (P.05). Irrespective of the CAD-CAM system, the overall laboratory working time for a digital workflow was significantly shorter than for the conventional workflow, since the dental technician needed less active working time. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Incorporation of composite defects from ultrasonic NDE into CAD and FE models

    Science.gov (United States)

    Bingol, Onur Rauf; Schiefelbein, Bryan; Grandin, Robert J.; Holland, Stephen D.; Krishnamurthy, Adarsh

    2017-02-01

    Fiber-reinforced composites are widely used in aerospace industry due to their combined properties of high strength and low weight. However, owing to their complex structure, it is difficult to assess the impact of manufacturing defects and service damage on their residual life. While, ultrasonic testing (UT) is the preferred NDE method to identify the presence of defects in composites, there are no reasonable ways to model the damage and evaluate the structural integrity of composites. We have developed an automated framework to incorporate flaws and known composite damage automatically into a finite element analysis (FEA) model of composites, ultimately aiding in accessing the residual life of composites and make informed decisions regarding repairs. The framework can be used to generate a layer-by-layer 3D structural CAD model of the composite laminates replicating their manufacturing process. Outlines of structural defects, such as delaminations, are automatically detected from UT of the laminate and are incorporated into the CAD model between the appropriate layers. In addition, the framework allows for direct structural analysis of the resulting 3D CAD models with defects by automatically applying the appropriate boundary conditions. In this paper, we show a working proof-of-concept for the composite model builder with capabilities of incorporating delaminations between laminate layers and automatically preparing the CAD model for structural analysis using a FEA software.

  8. Issues in assessing multi-institutional performance of BI-RADS-based CAD systems

    Science.gov (United States)

    Markey, Mia K.; Lo, Joseph Y.

    2005-04-01

    The purpose of this study was to investigate factors that impact the generalization of breast cancer computer-aided diagnosis (CAD) systems that utilize the Breast Imaging Reporting and Data System (BI-RADS). Data sets from four institutions were analyzed: Duke University Medical Center, University of Pennsylvania Medical Center, Massachusetts General Hospital, and Wake Forest University. The latter two data sets are subsets of the Digital Database for Screening Mammography. Each data set consisted of descriptions of mammographic lesions according to the BI-RADS lexicon, patient age, and pathology status (benign/malignant). Models were developed to predict pathology status from the BI-RADS descriptors and the patient age. Comparisons between the models built on data from the different institutions were made in terms of empirical (non-parametric) receiver operating characteristic (ROC) curves. Results suggest that BI-RADS-based CAD systems focused on specific classes of lesions may be more generally applicable than models that cover several lesion types. However, better generalization was seen in terms of the area under the ROC curve than in the partial area index (>90% sensitivity). Previous studies have illustrated the challenges in translating a BI-RADS-based CAD system from one institution to another. This study provides new insights into possible approaches to improve the generalization of BI-RADS-based CAD systems.

  9. Survey on the use of CAD-CAM technology by UK and Irish dental technicians.

    Science.gov (United States)

    Blackwell, E; Nesbit, M; Petridis, H

    2017-05-12

    Statement of the problem Digital workflows (CAD/CAM) have been introduced in dentistry during recent years. No published information exists on dental technicians' use and reporting of this technology.Purpose The aim of this cross sectional survey was to identify the extent digital technology has infiltrated the workplace and to investigate the factors affecting the use of CAD-CAM technology by dental laboratory technicians within Ireland and the UK.Materials and methods A web-based questionnaire was composed (Opinio, Object Planet Inc. Oslo, Norway) and distributed to UK and Irish dental technicians. Answers to all questions were anonymous and grouped such that general information was gathered initially, followed by branching of the survey into two sections depending on whether or not the respondent worked with CAD-CAM technology. Results were compiled and statistical analysis (Fisher's Exact test, SPSS, IBM, Armonk, New York, USA) was performed in order to investigate any correlation between various demographic variables and the answers provided.Results The survey was distributed to 760 UK technicians and 77 Irish technicians. The total number of completed surveys was 105, which yielded a total response rate of 14%. Most technicians reported using some form of CAD/CAM aspect in the workflow, and this was more significant for technicians working in large laboratories. Most training received was company-led. Large laboratories were also significantly correlated with less outsourcing of CAD/CAM work and a change in dental material use leading to the increase of zirconia and the decrease of noble alloys. Dental technicians did not report any significant change in working relationships and staffing as a result of CAD/CAM incorporation. High initial investment cost was the most common reason quoted from non-users, along with the lack of such technology in their working environment.

  10. Metabolite profiling reveals a role for atypical cinnamyl alcohol dehydrogenase CAD1 in the synthesis of coniferyl alcohol in tobacco xylem.

    Science.gov (United States)

    Damiani, Isabelle; Morreel, Kris; Danoun, Saïda; Goeminne, Geert; Yahiaoui, Nabila; Marque, Christiane; Kopka, Joachim; Messens, Eric; Goffner, Deborah; Boerjan, Wout; Boudet, Alain-Michel; Rochange, Soizic

    2005-11-01

    In angiosperms, lignin is built from two main monomers, coniferyl and sinapyl alcohol, which are incorporated respectively as G and S units in the polymer. The last step of their synthesis has so far been considered to be performed by a family of dimeric cinnamyl alcohol dehydrogenases (CAD2). However, previous studies on Eucalyptus gunnii xylem showed the presence of an additional, structurally unrelated, monomeric CAD form named CAD1. This form reduces coniferaldehyde to coniferyl alcohol, but is inactive on sinapaldehyde. In this paper, we report the functional characterization of CAD1 in tobacco (Nicotiana tabacum L.). Transgenic tobacco plants with reduced CAD1 expression were obtained through an RNAi strategy. These plants displayed normal growth and development, and detailed biochemical studies were needed to reveal a role for CAD1. Lignin analyses showed that CAD1 down-regulation does not affect Klason lignin content, and has a moderate impact on G unit content of the non-condensed lignin fraction. However, comparative metabolic profiling of the methanol-soluble phenolic fraction from basal xylem revealed significant differences between CAD1 down-regulated and wild-type plants. Eight compounds were less abundant in CAD1 down-regulated lines, five of which were identified as dimers or trimers of monolignols, each containing at least one moiety derived from coniferyl alcohol. In addition, 3-trans-caffeoyl quinic acid accumulated in the transgenic plants. Together, our results support a significant contribution of CAD1 to the synthesis of coniferyl alcohol in planta, along with the previously characterized CAD2 enzymes.

  11. The Unknown Oldowan: ~1.7-Million-Year-Old Standardized Obsidian Small Tools from Garba IV, Melka Kunture, Ethiopia.

    Directory of Open Access Journals (Sweden)

    Rosalia Gallotti

    Full Text Available The Oldowan Industrial Complex has long been thought to have been static, with limited internal variability, embracing techno-complexes essentially focused on small-to-medium flake production. The flakes were rarely modified by retouch to produce small tools, which do not show any standardized pattern. Usually, the manufacture of small standardized tools has been interpreted as a more complex behavior emerging with the Acheulean technology. Here we report on the ~1.7 Ma Oldowan assemblages from Garba IVE-F at Melka Kunture in the Ethiopian highland. This industry is structured by technical criteria shared by the other East African Oldowan assemblages. However, there is also evidence of a specific technical process never recorded before, i.e. the systematic production of standardized small pointed tools strictly linked to the obsidian exploitation. Standardization and raw material selection in the manufacture of small tools disappear at Melka Kunture during the Lower Pleistocene Acheulean. This proves that 1 the emergence of a certain degree of standardization in tool-kits does not reflect in itself a major step in cultural evolution; and that 2 the Oldowan knappers, when driven by functional needs and supported by a highly suitable raw material, were occasionally able to develop specific technical solutions. The small tool production at ~1.7 Ma, at a time when the Acheulean was already emerging elsewhere in East Africa, adds to the growing amount of evidence of Oldowan techno-economic variability and flexibility, further challenging the view that early stone knapping was static over hundreds of thousands of years.

  12. The Unknown Oldowan: ~1.7-Million-Year-Old Standardized Obsidian Small Tools from Garba IV, Melka Kunture, Ethiopia.

    Science.gov (United States)

    Gallotti, Rosalia; Mussi, Margherita

    2015-01-01

    The Oldowan Industrial Complex has long been thought to have been static, with limited internal variability, embracing techno-complexes essentially focused on small-to-medium flake production. The flakes were rarely modified by retouch to produce small tools, which do not show any standardized pattern. Usually, the manufacture of small standardized tools has been interpreted as a more complex behavior emerging with the Acheulean technology. Here we report on the ~1.7 Ma Oldowan assemblages from Garba IVE-F at Melka Kunture in the Ethiopian highland. This industry is structured by technical criteria shared by the other East African Oldowan assemblages. However, there is also evidence of a specific technical process never recorded before, i.e. the systematic production of standardized small pointed tools strictly linked to the obsidian exploitation. Standardization and raw material selection in the manufacture of small tools disappear at Melka Kunture during the Lower Pleistocene Acheulean. This proves that 1) the emergence of a certain degree of standardization in tool-kits does not reflect in itself a major step in cultural evolution; and that 2) the Oldowan knappers, when driven by functional needs and supported by a highly suitable raw material, were occasionally able to develop specific technical solutions. The small tool production at ~1.7 Ma, at a time when the Acheulean was already emerging elsewhere in East Africa, adds to the growing amount of evidence of Oldowan techno-economic variability and flexibility, further challenging the view that early stone knapping was static over hundreds of thousands of years.

  13. Unique CAD/CAM three-quarter crown restoration of a central incisor: a case report.

    Science.gov (United States)

    Goldberg, Marvin B; Siegel, Sharon C; Rezakani, Niloufar

    2013-07-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) dentistry has been in use for more than 2 decades. Recent improvements in this technology have made CAD/CAM restorations a viable alternative for routine dental care. This technology is being taught in dental schools to prepare students for contemporary dental practice and is particularly useful in unique restorative situations that allow conservation of tooth structure. This case report describes the restoration of a central incisor that was previously restored with an unesthetic three-quarter gold crown. The tooth exhibited recurrent caries and an unaffected labial wall of supported enamel. A CAD/CAM three-quarter crown was planned to conserve tooth structure. After preparation, the tooth was scanned for a CAD/CAM crown in order to fabricate a ceramic restoration, which was then milled and bonded, producing an esthetic result. Typically, in cases of esthetic enhancement, a labial laminate restoration is fabricated, but in this situation, a different approach was necessary to make a design for the lingual surface of an anterior tooth.

  14. Circulating irisin levels are lower in patients with either stable coronary artery disease (CAD) or myocardial infarction (MI) versus healthy controls, whereas follistatin and activin A levels are higher and can discriminate MI from CAD with similar to CK-MB accuracy.

    Science.gov (United States)

    Anastasilakis, Athanasios D; Koulaxis, Dimitrios; Kefala, Nikoleta; Polyzos, Stergios A; Upadhyay, Jagriti; Pagkalidou, Eirini; Economou, Fotios; Anastasilakis, Chrysostomos D; Mantzoros, Christos S

    2017-08-01

    Several myokines are produced by cardiac muscle. We investigated changes in myokine levels at the time of acute myocardial infarction (MI) and following reperfusion in relation to controls. Patients with MI (MI Group, n=31) treated with percutaneous coronary intervention (PCI) were compared to patients with stable coronary artery disease (CAD) subjected to scheduled PCI (CAD Group, n=40) and controls with symptoms mimicking CAD without stenosis in angiography (Control Group, n=43). The number and degree of stenosis were recorded. Irisin, follistatin, follistatin-like 3, activin A and B, ALT, AST, CK and CK-MB were measured at baseline and 6 or 24h after the intervention. MI and CAD patients had lower irisin than controls (p<0.001). MI patients had higher follistatin, activin A, CK, CK-MB and AST than CAD patients and controls (all p≤0.001). None of the myokines changed following reperfusion. Circulating irisin was associated with the degree of stenosis in all patients (p=0.05). Irisin was not inferior to CK-MB in predicting MI while folistatin and activin A could discriminate MI from CAD patients with similar to CK-MB accuracy. None of these myokines was altered following PCI in contrast to CK-MB. Irisin levels are lower in MI and CAD implying that their production may depend on myocadial blood supply. Follistatin and activin A are higher in MI than in CAD suggesting increased release due to myocardial necrosis. They can predict MI with accuracy similar to CK-MB and their role in the diagnosis of MI remains to be confirmed by prospective large clinical studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    International Nuclear Information System (INIS)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo; Pitocco, Dario; Di Stasio, Enrico; Trani, Carlo

    2016-01-01

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  16. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Radiological Sciences - Institute of Radiology, Rome (Italy); Pitocco, Dario [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Internal Medicine, Rome (Italy); Di Stasio, Enrico [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Clinical Biochemistry, Rome (Italy); Trani, Carlo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Cardiovascular Medicine - Institute of Cardiology, Rome (Italy)

    2016-03-15

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  17. Integrated digital planning and management tools - the example of buildings; Integrierte digitale Planungs- und Management-Werkzeuge - am Beispiel von Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Gauchel, J. [WIBc, Objektorientierte Systeme fuer Gebaeudeplanung und -management, Karlsruhe (Germany)

    1995-12-31

    In chapter 4 of the anthology about building control integrated digital planning and management tools are described. Integrated planning and management tools are task-orientated data processing applications, which are integrated into a data management and a common user-interface. The following aspects are discussed: realistic modelling, CAD-systems, object-orientated system architecture as well as building management. (BWI) [Deutsch] Kapitel 4 des Sammelbandes ueber Building Control ist Integrierten digitalen Planungs- und Managementwerkzeugen gewindmet. Unter Integrierten Planungs- und Managementwerkzeugen werden dabei aufgabenorientierte EDV-Anwendungen verstanden, die in eine gemeinsame Datenverwaltung und ein gemeinsames Nutzer-Interface eingebunden sind. Folgende Themen werden angesprochen: Realistische Modellierung, CAD-Systeme, objektorientierte Systemarchitekturen sowie Gebaeudemanagement. (BWI)

  18. Displacement of cryomodule in CADS injector II

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Jiandong; Zhang, Bin; Wang, Fengfeng; Wan, Yuqin; Sun, Guozhen; Yao, Junjie; Zhang, Juihui; He, Yuan [Chinese Academy of Sciences, Lanzhou (China). Inst. of Modern Physics

    2017-06-15

    As Cryomodule can easily reduce higher power consumption and length of an accelerator and the accelerator can be operated more continuously. The Chinese academy of sciences institute of modern physics is developing an accelerator driven subcritical system (CADS) Injector II. Cryomodules are extremely complex systems, and their design optimization is strongly dependent on the accelerator application for which they are intended.

  19. [Early detection of addictive behaviour in primary health care. Use of MULTICAGE CAD-4].

    Science.gov (United States)

    Rodríguez Monje, M Teresa; Pedrero Pérez, Eduardo J; Fernández Girón, Mercedes; Gallardo Alonso, Fernando; Sanz Cuesta, Teresa

    2009-01-01

    To find out the frequency of specific disorders within the general population using primary healthcare relating to the control of impulses with addictive risk. A cross-sectional descriptive study. Urban health centre, Area 9 of the Madrid Health Service (Spain). A total of 457 patients who came to primary care (PA) were selected by consecutive sampling. Self-completion of the MULTICAGE-CAD4 survey (which measure eight scales for the risky behaviour being studied). There was a risk in at least one of the scales in 46.4% of the sample, of which 17.3% (13.7-20.9) showed risky behaviour on the alcohol scale; 9% (6.2-11.7) for other drugs; 4.4% (2.4-6.4) for gambling; 9.4% (6.6-12.2) for addiction to the Internet; 4.8% (2.7-6.7) for addiction to videogames; 18.8% (15.1-22.5) for eating disorders; 16% (12.5-19.4) for compulsive shopping and 5.5% (3.3-7.7) for addiction to sex. The occurrence of addiction to alcohol, gambling and sex were higher for men, while eating disorders were more prevalent in women. We are facing a widespread set of problems related to addictions that are often hidden; this study shows that these addictions can be detected within primary healthcare by effective screening tools such as MULTICAGE CAD-4, which is both economic, and easy to implement within primary healthcare centres.

  20. Extension of a Computer Assisted Decision Support (CADS) Study to Improve Outcomes in Patients with Type 2 DM Treated by Primary Care Providers. Addendum

    Science.gov (United States)

    2015-04-01

    physicians’ assistants, who are not necessarily equipped with the latest information and tools to provide optimum care nor have the time required to...web-assisted DM management, most have used the web for patient education, performance monitoring, risk stratification , and case management by nurses...research staff to maintain CDMP and CADS and to assist with patient and provider problems that could not be solved by the research staff. Reportable

  1. A Stepwise Psychotherapy Intervention for Reducing Risk in Coronary Artery Disease (SPIRR-CAD): Results of an Observer-Blinded, Multicenter, Randomized Trial in Depressed Patients With Coronary Artery Disease.

    Science.gov (United States)

    Herrmann-Lingen, Christoph; Beutel, Manfred E; Bosbach, Alexandra; Deter, Hans-Christian; Fritzsche, Kurt; Hellmich, Martin; Jordan, Jochen; Jünger, Jana; Ladwig, Karl-Heinz; Michal, Matthias; Petrowski, Katja; Pieske, Burkert; Ronel, Joram; Söllner, Wolfgang; Stöhr, Andreas; Weber, Cora; de Zwaan, Martina; Albus, Christian

    2016-01-01

    Depression predicts adverse prognosis in patients with coronary artery disease (CAD), but previous treatment trials yielded mixed results. We tested the hypothesis that stepwise psychotherapy improves depressive symptoms more than simple information. In a multicenter trial, we randomized 570 CAD patients scoring higher than 7 on the Hospital Anxiety and Depression Scale-depression subscale to usual care plus either one information session (UC-IS) or stepwise psychotherapy (UC-PT). UC-PT patients received three individual psychotherapy sessions. Those still depressed were offered group psychotherapy (25 sessions). The primary outcome was changed in the Hospital Anxiety and Depression Scale-depression scores from baseline to 18 months. Preplanned subgroup analyses examined whether treatment responses differed by patients' sex and personality factors (Type D). The mean (standard deviation) depression scores declined from 10.4 (2.5) to 8.7 (4.1) at 18 months in UC-PT and from 10.4 (2.5) to 8.9 (3.9) in UC-IS (both p psychotherapy failed to improve depressive symptoms in CAD patients more than UC-IS. The intervention might be beneficial for depressed CAD patients with Type D personality. However, this finding requires further study. www.clinicaltrials.gov NCT00705965; www.isrctn.com ISRCTN76240576.

  2. Color Stability of CAD/CAM Fabricated Inlays after Accelerated Artificial Aging.

    Science.gov (United States)

    Karaokutan, Isil; Yilmaz Savas, Tuba; Aykent, Filiz; Ozdere, Eda

    2016-08-01

    To investigate the influence of accelerated artificial aging on the color stability of three different inlay restorations produced with a CAD/CAM system. Thirty non-carious human mandibular molar teeth were used. The teeth were embedded in autopolymerizing acrylic resin blocks. Standard Class I inlay cavities were prepared, and the teeth were randomly divided into three groups (n = 10) to fabricate inlay restorations: (1) a feldspathic-ceramic group, (2) a resin nano-ceramic group, and (3) a leucite glass-ceramic group. Optical impressions were made with CEREC software, and the restorations were designed and then milled. The inlays were adhesively cemented with a dual-polymerizing resin cement and left in distilled water at room temperature for 1 week. Color measurements were performed with a spectrophotometer before and after accelerated aging in a weathering machine with a total energy of 150 kJ/m(2) . Changes in color (∆E, ∆L, ∆a, ∆b, ∆C) were determined using the CIE L*a*b* system. The results were assessed using a one-way ANOVA and Tukey's HSD test (p = 0.05). The color changes of the materials ranged from 2.1 to 9.29. The highest color change was seen in the resin nano-ceramic material. This change was not clinically acceptable (∆E > 5.5). No significant differences were found in the ∆L and ∆a values of the test groups. Color changes were observed in each evaluated material after accelerated aging. All CAD/CAM inlays became darker in appearance, more saturated, a little reddish, and more yellow. © 2015 by the American College of Prosthodontists.

  3. Fractional flow reserve derived from coronary CT angiography in stable coronary disease: a new standard in non-invasive testing?

    International Nuclear Information System (INIS)

    Noergaard, B.L.; Jensen, J.M.; Leipsic, J.

    2015-01-01

    Fractional flow reserve (FFR) measured during invasive coronary angiography is the gold standard for lesion-specific decisions on coronary revascularization in patients with stable coronary artery disease (CAD). Current guidelines recommend non-invasive functional or anatomic testing as a gatekeeper to the catheterization laboratory. However, the ''holy grail'' in non-invasive testing of CAD is to establish a single test that quantifies both coronary lesion severity and the associated ischemia. Most evidence to date of such a test is based on the addition of computational analysis of FFR to the anatomic information obtained from standard-acquired coronary CTA data sets at rest (FFR CT ). This review summarizes the clinical evidence for the use of FFR CT in stable CAD in context to the diagnostic performance of other non-invasive testing modalities. (orig.)

  4. Sophistication and integration of plant engineering CAD-CAE systems

    International Nuclear Information System (INIS)

    Yoshinaga, Toshiaki; Hanyu, Masaharu; Ota, Yoshimi; Kobayashi, Yasuhiro.

    1995-01-01

    In respective departments in charge of basic planning, design, manufacture, inspection and construction of nuclear power plants, by the positive utilization of CAD/CAE system, efficient workings have been advanced. This time, the plant integrated CAE system wich heightens the function of these individual systems, and can make workings efficient and advanced by unifying and integrating them was developed. This system is composed of the newly developed application system and the data base system which enables the unified management of engineering data and high speed data conversion in addition to the CAD system for three-dimensional plant layout planning. On the basis of the rich experience and the proposal of improvement of designers by the application of the CAD system for three-dimensional plant layout planning to actual machines, the automation, speed increase and the visualization of input and output by graphical user interface (GUI) in the processing of respective applications were made feasible. As the advancement of plant CAE system, scenic engineering system, integrated layout CAE system, electric instrumentation design CAE system and construction planning CAE system are described. As for the integration of plant CAE systems, the integrated engineering data base, the combination of plant CAE systems, and the operation management in the dispersed environment of networks are reported. At present, Hitachi Ltd. exerts efforts for the construction of atomic energy product in formation integrated management system as the second stage of integration. (K.I.)

  5. Advances in computer-aided engineering : CAD/CAM-research at Delft University of Technology. Report of the VF-project CAD/CAM 1989-1994

    NARCIS (Netherlands)

    Undetermined, U.

    1994-01-01

    This book contains a collection of articles describing on-going CAD/CAM-research at several engineering faculties at Delft University of Technology. Two main themes covered in this book are 'Conceptual design of complex products' and 'Product modelling and product data exchange'.

  6. Integrating 3D CAD data for manufacturing and fabrication the core model of reactor TRIGA PUSPATI

    International Nuclear Information System (INIS)

    Abu Bakar Harun

    2005-01-01

    This paper describe the intrigue integration of digital 3 Dimensional Computer Aided Design (3D CAD) data manipulation for the Core Model fabrication of REAKTOR TRIGA PUSPATI and ready for mass manufacturing. 3 Dimensional CAD data from Computer Aided Design program will be used as an interpreter in the fabrication of this project. The Core Model of REAKTOR TRIGA PUSPATI will be fabricated with the aid of 3D CAD drawings and digital files. The components will be segregated and divided into 2 categories namely Conventional d Rapid Fabrication. (Author)

  7. Gold standards and expert panels: a pulmonary nodule case study with challenges and solutions

    Science.gov (United States)

    Miller, Dave P.; O'Shaughnessy, Kathryn F.; Wood, Susan A.; Castellino, Ronald A.

    2004-05-01

    Comparative evaluations of reader performance using different modalities, e.g. CT with computer-aided detection (CAD) vs. CT without CAD, generally require a "truth" definition based on a gold standard. There are many situations in which a true invariant gold standard is impractical or impossible to obtain. For instance, small pulmonary nodules are generally not assessed by biopsy or resection. In such cases, it is common to use a unanimous consensus or majority agreement from an expert panel as a reference standard for actionability in lieu of the unknown gold standard for disease. Nonetheless, there are three major concerns about expert panel reference standards: (1) actionability is not synonymous with disease (2) it may be possible to obtain different conclusions about which modality is better using different rules (e.g. majority vs. unanimous consensus), and (3) the variability associated with the panelists is not formally captured in the p-values or confidence intervals that are generally produced for estimating the extent to which one modality is superior to the other. A multi-reader-multi-case (MRMC) receiver operating characteristic (ROC) study was performed using 90 cases, 15 readers, and a reference truth based on 3 experienced panelists. The primary analyses were conducted using a reference truth of unanimous consensus regarding actionability (3 out of 3 panelists). To assess the three concerns noted above: (1) additional data from the original radiology reports were compared to the panel (2) the complete analysis was repeated using different definitions of truth, and (3) bootstrap analyses were conducted in which new truth panels were constructed by picking 1, 2, or 3 panelists at random. The definition of the reference truth affected the results for each modality (CT with CAD and CT without CAD) considered by itself, but the effects were similar, so the primary analysis comparing the modalities was robust to the choice of the reference truth.

  8. CDMS: CAD data set system design description. Revision 1

    International Nuclear Information System (INIS)

    Gray, E.L.

    1994-01-01

    This document is intended to formalize the program design of the CAD Data Set Management System (CDMS) and to be the vehicle to communicate the design to the Engineering, Design Services, and Configuration Management organizations and the WHC IRM Analysts/Programmers. The SDD shows how the software system will be structured to satisfy the requirements identified in the WHC-SD-GN-CSRS-30005 CDMS Software Requirement Specification (SRS). It is a description of the software structure, software components, interfaces, and data that make up the CDMS System. The design descriptions contained within this document will describe in detail the software product that will be developed to assist the aforementioned organizations for the express purpose of managing CAD data sets associated with released drawings, replacing the existing locally developed system and laying the foundation for automating the configuration management

  9. The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses.

    Science.gov (United States)

    Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori

    2017-07-26

    The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.

  10. Listeria monocytogenes CadC Regulates Cadmium Efflux and Fine-tunes Lipoprotein Localization to Escape the Host Immune Response and Promote Infection.

    Science.gov (United States)

    Pombinho, Rita; Camejo, Ana; Vieira, Ana; Reis, Olga; Carvalho, Filipe; Almeida, Maria Teresa; Pinheiro, Jorge Campos; Sousa, Sandra; Cabanes, Didier

    2017-05-01

    Listeria monocytogenes is a major intracellular human foodborne bacterial pathogen. We previously revealed L. monocytogenes cadC as highly expressed during mouse infection. Here we show that L. monocytogenes CadC is a sequence-specific, DNA-binding and cadmium-dependent regulator of CadA, an efflux pump conferring cadmium resistance. CadC but not CadA is required for L. monocytogenes infection in vivo. Interestingly, CadC also directly represses lspB, a gene encoding a lipoprotein signal peptidase whose expression appears detrimental for infection. lspB overexpression promotes the release of the LpeA lipoprotein to the extracellular medium, inducing tumor necrosis factor α and interleukin 6 expression, thus impairing L. monocytogenes survival in macrophages. We propose that L. monocytogenes uses CadC to repress lspB expression during infection to avoid LpeA exposure to the host immune system, diminishing inflammatory cytokine expression and promoting intramacrophagic survival and virulence. CadC appears as the first metal efflux pump regulator repurposed during infection to fine-tune lipoprotein processing and host responses. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  11. Light irradiance through novel CAD-CAM block materials and degree of conversion of composite cements.

    Science.gov (United States)

    Lise, Diogo Pedrollo; Van Ende, Annelies; De Munck, Jan; Yoshihara, Kumiko; Nagaoka, Noriyuki; Cardoso Vieira, Luiz Clovis; Van Meerbeek, Bart

    2018-02-01

    To assess light irradiance (LI) delivered by two light-curing units (LCU's) and to measure the degree of conversion (DC) of three composite cements, when cured through different thicknesses of two novel CAD-CAM block materials. 100-μm-thick films of a dual-curable composite cement (G-CEM LinkAce, GC), a light-curable flowable resin-based composite (RBC) (G-ænial Universal Flo, GC) and a micro-hybrid RBC (G-ænial Posterior, GC) were investigated as luting agents. Two 'polymer-ceramic' CAD-CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were sectioned in slabs with different thicknesses (1, 3 and 5mm). LI at the bottom of the specimens was measured using a calibrated spectrometer, while being light-cured through the CAD-CAM block slabs for 40s with a low- (±500mW/cm 2 ) or high- (±1,600mW/cm 2 ) irradiance LCU (n=5). After light-curing, micro-Raman spectra of the composite films were acquired to determine DC at 5min, 10min, 1h and 24h. LI data were statistically analyzed by Kruskal-Wallis followed by post-hoc comparisons, while a linear mixed-effect model was applied for the DC analysis. In addition, the CAD-CAM blocks ultrastructure was characterized upon argon-ion slicing using scanning transmission electron microscopy (STEM). Finally, light transmission (LT) through each CAD-CAM block material was assessed using a spectrophotometer. Curing-light attenuation and DC were significantly influenced by thickness and type of the overlying material. LCU only had a significant effect on DC of the micro-hybrid RBC. DC significantly increased over time for all composite cements. CAD-CAM block structural analysis revealed a relatively small and homogenous filler configuration (mean filler size of 0.2-0.5μm) for Cerasmart, while Enamic contained ceramic grains varying in shape and size (1-10μm), which were interconnected by the polymer-based network. LT was much higher at a wavelength range of 300-800nm for Cerasmart than for Enamic. Light-curable composite cements

  12. Implementation of a computer-aided detection tool for quantification of intracranial radiologic markers on brain CT images

    Science.gov (United States)

    Aghaei, Faranak; Ross, Stephen R.; Wang, Yunzhi; Wu, Dee H.; Cornwell, Benjamin O.; Ray, Bappaditya; Zheng, Bin

    2017-03-01

    Aneurysmal subarachnoid hemorrhage (aSAH) is a form of hemorrhagic stroke that affects middle-aged individuals and associated with significant morbidity and/or mortality especially those presenting with higher clinical and radiologic grades at the time of admission. Previous studies suggested that blood extravasated after aneurysmal rupture was a potentially clinical prognosis factor. But all such studies used qualitative scales to predict prognosis. The purpose of this study is to develop and test a new interactive computer-aided detection (CAD) tool to detect, segment and quantify brain hemorrhage and ventricular cerebrospinal fluid on non-contrasted brain CT images. First, CAD segments brain skull using a multilayer region growing algorithm with adaptively adjusted thresholds. Second, CAD assigns pixels inside the segmented brain region into one of three classes namely, normal brain tissue, blood and fluid. Third, to avoid "black-box" approach and increase accuracy in quantification of these two image markers using CT images with large noise variation in different cases, a graphic User Interface (GUI) was implemented and allows users to visually examine segmentation results. If a user likes to correct any errors (i.e., deleting clinically irrelevant blood or fluid regions, or fill in the holes inside the relevant blood or fluid regions), he/she can manually define the region and select a corresponding correction function. CAD will automatically perform correction and update the computed data. The new CAD tool is now being used in clinical and research settings to estimate various quantitatively radiological parameters/markers to determine radiological severity of aSAH at presentation and correlate the estimations with various homeostatic/metabolic derangements and predict clinical outcome.

  13. ITER Equatorial Port plug engineering: Design and remote handling activities supported by Virtual Reality tools

    International Nuclear Information System (INIS)

    Keller, Delphine; Dechelle, Christian; Doceul, Louis; Madeleine, Sylvain; Martins, Jean Pierre; Measson, Yvan; Patterlini, Jean Claude; Wagrez, Julien

    2011-01-01

    In the context of ITER, CEA/IRFM has participated to the design and integration of several components in the Equatorial Port plug region. Particularly, in the framework of the grant F4E-2008-GRT-09-PNS-TBM, CEA/IRFM has contributed to the test blanket module system (TBS) design and robot access feasibility study in the Port Cell. Simulations of the maintenance procedure were studied and fully integrated to the design process, enabling to provide space reservation for human and robotic access. For this mean, CEA/IRFM has used a CEA LIST Virtual Reality simulation software directly integrated to the Solidworks CAD software. The feasibility to connect/dis-connect the pipes in front of the Bioshield by a set of potential standard industrial arms was demonstrated. Aiming to give more realism to maintenance scenario and CAD models, CEA IRFM has decided to build a Virtual Reality platform in the institute, integrated to the design office. With the expertise of CEA LIST, this platform aims to provide the nearest possible links between design and remote handling needs. This paper presents the outcome of the robot access study and discusses about the Virtual Reality tools that are being developed for these applications.

  14. ITER Equatorial Port plug engineering: Design and remote handling activities supported by Virtual Reality tools

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Delphine, E-mail: delphine.keller@cea.fr [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Dechelle, Christian; Doceul, Louis; Madeleine, Sylvain; Martins, Jean Pierre [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Measson, Yvan [CEA, LIST, Interactive Robotics Unit, 18 route du Panorama, BP6, F-92265 Fontenay Aux Roses (France); Patterlini, Jean Claude; Wagrez, Julien [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France)

    2011-10-15

    In the context of ITER, CEA/IRFM has participated to the design and integration of several components in the Equatorial Port plug region. Particularly, in the framework of the grant F4E-2008-GRT-09-PNS-TBM, CEA/IRFM has contributed to the test blanket module system (TBS) design and robot access feasibility study in the Port Cell. Simulations of the maintenance procedure were studied and fully integrated to the design process, enabling to provide space reservation for human and robotic access. For this mean, CEA/IRFM has used a CEA LIST Virtual Reality simulation software directly integrated to the Solidworks CAD software. The feasibility to connect/dis-connect the pipes in front of the Bioshield by a set of potential standard industrial arms was demonstrated. Aiming to give more realism to maintenance scenario and CAD models, CEA IRFM has decided to build a Virtual Reality platform in the institute, integrated to the design office. With the expertise of CEA LIST, this platform aims to provide the nearest possible links between design and remote handling needs. This paper presents the outcome of the robot access study and discusses about the Virtual Reality tools that are being developed for these applications.

  15. Reproducibility of prompts in computer-aided detection (CAD) of breast cancer

    International Nuclear Information System (INIS)

    Taylor, C.G.; Champness, J.; Reddy, M.; Taylor, P.; Potts, H.W.W.; Given-Wilson, R.

    2003-01-01

    AIM: We evaluated the reproducibility of prompts using the R2 ImageChecker M2000 computer-aided detection (CAD) system. MATERIALS AND METHODS: Forty selected two-view mammograms of women with breast cancer were digitized and analysed using the ImageChecker on 10 separate occasions. The mammograms were chosen to provide both straightforward and subtle signs of malignancy. Data analysed included mammographic abnormality, pathology, and whether the cancer was prompted or given an emphasized prompt. RESULTS: Correct prompts were generated in 86 out of 100 occasions for screen-detected cancers. Reproducibility was less in the other categories of more subtle cancers: 21% for cancers previously missed by CAD, a group that contained more grade 1 and small (<10 mm) tumours. Prompts for calcifications were more reproducible than those for masses (76% versus 53%) and these cancers were more likely to have an emphasized prompt. CONCLUSIONS: Probably the most important cause of variability of prompts is shifts in film position between sequential digitizations. Consequently subtle lesions that are only just above the threshold for display may not be prompted on repeat scanning. However, users of CAD should be aware that even emphasized prompts are not consistently reproducible

  16. Use of standardized multidimensional evaluation tools and the emergence of the case manager's professional identity in France.

    Science.gov (United States)

    Nugue, Mathilde; De Stampa, Matthieu; Couturier, Yves; Somme, Dominique

    2012-01-01

    In France, the national public health plan proposes a group of innovations including the initiation of case management for older adults in complex situations, particularly those with cognitive disorders. In this context, public authorities asked case managers to use a standardized multidimensional evaluation tool. The results of a qualitative study on the pertinence of such a tool relative to the emergence of this new professional field are described. Early use of an evaluation tool seems to be linked to the emergence of a new professional identity for recently recruited case managers. Factors determining the strength of this link are training tool standardization, computerization, and local structure's involvement. Our results contribute to identifying one of the ways by which professional identity can be changed to become a case manager.

  17. Bridging CAGD knowledge into CAD/CG applications: Mathematical theories as stepping stones of innovations

    Science.gov (United States)

    Gobithaasan, R. U.; Miura, Kenjiro T.; Hassan, Mohamad Nor

    2014-07-01

    Computer Aided Geometric Design (CAGD) which surpasses the underlying theories of Computer Aided Design (CAD) and Computer Graphics (CG) has been taught in a number of Malaysian universities under the umbrella of Mathematical Sciences' faculty/department. On the other hand, CAD/CG is taught either under the Engineering or Computer Science Faculty. Even though CAGD researchers/educators/students (denoted as contributors) have been enriching this field of study by means of article/journal publication, many fail to convert the idea into constructive innovation due to the gap that occurs between CAGD contributors and practitioners (engineers/product/designers/architects/artists). This paper addresses this issue by advocating a number of technologies that can be used to transform CAGD contributors into innovators where immediate impact in terms of practical application can be experienced by the CAD/CG practitioners. The underlying principle of solving this issue is twofold. First would be to expose the CAGD contributors on ways to turn mathematical ideas into plug-ins and second is to impart relevant CAGD theories to CAD/CG to practitioners. Both cases are discussed in detail and the final section shows examples to illustrate the importance of turning mathematical knowledge into innovations.

  18. FROM CAD MODEL TO 3D PRINT VIA “STL” FILE FORMAT

    Directory of Open Access Journals (Sweden)

    Cătălin IANCU

    2010-06-01

    Full Text Available The paper work presents the STL file format, which is now used for transferring information from CAD software to a 3D printer, for obtaining the solid model in Rapid prototyping and Computer Aided Manufacturing. It’s presented also the STL format structure, its history, limitations and further development, as well as its new version to arrive and other similar file formats. As a conclusion, STL files used to transfer data from CAD package to 3D printers has a series of limitations and therefore new formats will replace it soon.

  19. Mobile Technology and CAD Technology Integration in Teaching Architectural Design Process for Producing Creative Product

    Science.gov (United States)

    Bin Hassan, Isham Shah; Ismail, Mohd Arif; Mustafa, Ramlee

    2011-01-01

    The purpose of this research is to examine the effect of integrating the mobile and CAD technology on teaching architectural design process for Malaysian polytechnic architectural students in producing a creative product. The website is set up based on Caroll's minimal theory, while mobile and CAD technology integration is based on Brown and…

  20. Fatigue resistance and crack propensity of large MOD composite resin restorations: direct versus CAD/CAM inlays.

    Science.gov (United States)

    Batalha-Silva, Silvana; de Andrada, Mauro Amaral Caldeira; Maia, Hamilton Pires; Magne, Pascal

    2013-03-01

    To assess the influence of material/technique selection (direct vs. CAD/CAM inlays) for large MOD composite adhesive restorations and its effect on the crack propensity and in vitro accelerated fatigue resistance. A standardized MOD slot-type tooth preparation was applied to 32 extracted maxillary molars (5mm depth and 5mm bucco-palatal width) including immediately sealed dentin for the inlay group. Fifteen teeth were restored with direct composite resin restoration (Miris2) and 17 teeth received milled inlays using Paradigm MZ100 block in the CEREC machine. All inlays were adhesively luted with a light curing composite resin (Filtek Z100). Enamel shrinkage-induced cracks were tracked with photography and transillumination. Cyclic isometric chewing (5 Hz) was simulated, starting with a load of 200 N (5000 cycles), followed by stages of 400, 600, 800, 1000, 1200 and 1400 N at a maximum of 30,000 cycles each. Samples were loaded until fracture or to a maximum of 185,000 cycles. Teeth restored with the direct technique fractured at an average load of 1213 N and two of them withstood all loading cycles (survival=13%); with inlays, the survival rate was 100%. Most failures with Miris2 occurred above the CEJ and were re-restorable (67%), but generated more shrinkage-induced cracks (47% of the specimen vs. 7% for inlays). CAD/CAM MZ100 inlays increased the accelerated fatigue resistance and decreased the crack propensity of large MOD restorations when compared to direct restorations. While both restorative techniques yielded excellent fatigue results at physiological masticatory loads, CAD/CAM inlays seem more indicated for high-load patients. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  1. IPAD 2: Advances in Distributed Data Base Management for CAD/CAM

    Science.gov (United States)

    Bostic, S. W. (Compiler)

    1984-01-01

    The Integrated Programs for Aerospace-Vehicle Design (IPAD) Project objective is to improve engineering productivity through better use of computer-aided design and manufacturing (CAD/CAM) technology. The focus is on development of technology and associated software for integrated company-wide management of engineering information. The objectives of this conference are as follows: to provide a greater awareness of the critical need by U.S. industry for advancements in distributed CAD/CAM data management capability; to present industry experiences and current and planned research in distributed data base management; and to summarize IPAD data management contributions and their impact on U.S. industry and computer hardware and software vendors.

  2. A New Browser-based, Ontology-driven Tool for Generating Standardized, Deep Descriptions of Geoscience Models

    Science.gov (United States)

    Peckham, S. D.; Kelbert, A.; Rudan, S.; Stoica, M.

    2016-12-01

    Standardized metadata for models is the key to reliable and greatly simplified coupling in model coupling frameworks like CSDMS (Community Surface Dynamics Modeling System). This model metadata also helps model users to understand the important details that underpin computational models and to compare the capabilities of different models. These details include simplifying assumptions on the physics, governing equations and the numerical methods used to solve them, discretization of space (the grid) and time (the time-stepping scheme), state variables (input or output), model configuration parameters. This kind of metadata provides a "deep description" of a computational model that goes well beyond other types of metadata (e.g. author, purpose, scientific domain, programming language, digital rights, provenance, execution) and captures the science that underpins a model. While having this kind of standardized metadata for each model in a repository opens up a wide range of exciting possibilities, it is difficult to collect this information and a carefully conceived "data model" or schema is needed to store it. Automated harvesting and scraping methods can provide some useful information, but they often result in metadata that is inaccurate or incomplete, and this is not sufficient to enable the desired capabilities. In order to address this problem, we have developed a browser-based tool called the MCM Tool (Model Component Metadata) which runs on notebooks, tablets and smart phones. This tool was partially inspired by the TurboTax software, which greatly simplifies the necessary task of preparing tax documents. It allows a model developer or advanced user to provide a standardized, deep description of a computational geoscience model, including hydrologic models. Under the hood, the tool uses a new ontology for models built on the CSDMS Standard Names, expressed as a collection of RDF files (Resource Description Framework). This ontology is based on core concepts

  3. Visual operations management tools applied to the oil pipelines and terminals standardization process: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the process by which visual operations management (VOM) tools were implemented, concerning standards and operational procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. It provides: a brief literature review of visual operations management tools applied to total quality management and the standardization processes; a discussion of the assumptions from the second level of VOM (visual standards) upon which TRANSPETRO's oil pipelines and terminals business processes and operational procedures are based; and a description of the VOM implementation process involving more than 100 employees and one illustrative example of 'Quick Guides' for right-of- way management activities. Finally, it discusses the potential impacts and benefits of using VOM tools in the current practices in TRANSPETRO's Oil Pipelines and Terminals Unit, reinforcing the importance of such visual guides as vital to implement regional and corporate procedures, focusing on the main operational processes. (author)

  4. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    International Nuclear Information System (INIS)

    Lee, Eun Sun; Kim, Se Hyung; Im, Jong Pil; Kim, Sang Gyun; Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn

    2015-01-01

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  5. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sun [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Kim, Se Hyung, E-mail: shkim7071@gmail.com [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Im, Jong Pil; Kim, Sang Gyun [Department of Internal Medicine, Seoul National University Hospital (Korea, Republic of); Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of)

    2015-04-15

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  6. Ratsnake: A Versatile Image Annotation Tool with Application to Computer-Aided Diagnosis

    Directory of Open Access Journals (Sweden)

    D. K. Iakovidis

    2014-01-01

    Full Text Available Image segmentation and annotation are key components of image-based medical computer-aided diagnosis (CAD systems. In this paper we present Ratsnake, a publicly available generic image annotation tool providing annotation efficiency, semantic awareness, versatility, and extensibility, features that can be exploited to transform it into an effective CAD system. In order to demonstrate this unique capability, we present its novel application for the evaluation and quantification of salient objects and structures of interest in kidney biopsy images. Accurate annotation identifying and quantifying such structures in microscopy images can provide an estimation of pathogenesis in obstructive nephropathy, which is a rather common disease with severe implication in children and infants. However a tool for detecting and quantifying the disease is not yet available. A machine learning-based approach, which utilizes prior domain knowledge and textural image features, is considered for the generation of an image force field customizing the presented tool for automatic evaluation of kidney biopsy images. The experimental evaluation of the proposed application of Ratsnake demonstrates its efficiency and effectiveness and promises its wide applicability across a variety of medical imaging domains.

  7. Análisis geométrico de un perfil alar mediante técnicas CAD

    OpenAIRE

    Suffo, Miguel

    2016-01-01

    Los resultados del aprendizaje de este tutorial deben ser, entre otros: - Conocer las técnicas CAD orientadas al análisis de curvatura de formas geométricas - Saber aplicar entidades geométricas de curvas complejas en diseño aeronáutico - Comparar diferentes herramientas CAD para un mismo propósito

  8. Probability Density Functions for the CALIPSO Lidar Version 4 Cloud-Aerosol Discrimination (CAD) Algorithm

    Science.gov (United States)

    Liu, Z.; Kar, J.; Zeng, S.; Tackett, J. L.; Vaughan, M.; Trepte, C. R.; Omar, A. H.; Hu, Y.; Winker, D. M.

    2017-12-01

    In the CALIPSO retrieval algorithm, detection layers in the lidar measurements is followed by their classification as a "cloud" or "aerosol" using 5-dimensional probability density functions (PDFs). The five dimensions are the mean attenuated backscatter at 532 nm, the layer integrated total attenuated color ratio, the mid-layer altitude, integrated volume depolarization ratio and latitude. The new version 4 (V4) level 2 (L2) data products, released in November 2016, are the first major revision to the L2 product suite since May 2010. Significant calibration changes in the V4 level 1 data necessitated substantial revisions to the V4 L2 CAD algorithm. Accordingly, a new set of PDFs was generated to derive the V4 L2 data products. The V4 CAD algorithm is now applied to layers detected in the stratosphere, where volcanic layers and occasional cloud and smoke layers are observed. Previously, these layers were designated as `stratospheric', and not further classified. The V4 CAD algorithm is also applied to all layers detected at single shot (333 m) resolution. In prior data releases, single shot detections were uniformly classified as clouds. The CAD PDFs used in the earlier releases were generated using a full year (2008) of CALIPSO measurements. Because the CAD algorithm was not applied to stratospheric features, the properties of these layers were not incorporated into the PDFs. When building the V4 PDFs, the 2008 data were augmented with additional data from June 2011, and all stratospheric features were included. The Nabro and Puyehue-Cordon volcanos erupted in June 2011, and volcanic aerosol layers were observed in the upper troposphere and lower stratosphere in both the northern and southern hemispheres. The June 2011 data thus provides the stratospheric aerosol properties needed for comprehensive PDF generation. In contrast to earlier versions of the PDFs, which were generated based solely on observed distributions, construction of the V4 PDFs considered the

  9. Fatigue resistance of CAD/CAM resin composite molar crowns.

    NARCIS (Netherlands)

    Shembish, F.A.; Tong, H.; Kaizer, M.; Janal, M.N.; Thompson, V.P.; Opdam, N.J.M.; Zhang, Y.

    2016-01-01

    OBJECTIVE: To demonstrate the fatigue behavior of CAD/CAM resin composite molar crowns using a mouth-motion step-stress fatigue test. Monolithic leucite-reinforced glass-ceramic crowns were used as a reference. METHODS: Fully anatomically shaped monolithic resin composite molar crowns (Lava

  10. Is CEUS (contrast enhanced ultrasonography a useful tool in a beginner’s hands? How much can CAD (computer assisted diagnosis prototype help us in the characterization of malignancy in focal lesions of the liver?

    Directory of Open Access Journals (Sweden)

    Tudor Voicu Moga1,

    2016-12-01

    Full Text Available OBJECTIVES CEUS improved the characterization of focal lesions of the liver (FLLs, but it remains an operator-dependent method. The goal of this scientific paper was to test a computer assisted diagnosis (CAD prototype. MATERIALS AND METHODS 97 CEUS videos [34% hepatocellular carcinomas (HCC, 12.3% hypervascular metastases (HiperM, 11.3% hypovascular metastases (HipoM, 24.7% hemangiomas (HMG, 17.5% focal nodular hyperplasia (FNH] were used to develop a CAD prototype based on an algorithm that tested a binary decision classifier. Two young MDs, two experts and the CAD prototype, reevaluated 50 CEUS videos (diagnosis of benign vs. malignant lesions, in order to evaluate the beginner vs. expert diagnostic gap, the first being blinded by clinical data. RESULTS I-Beginner misdiagnosed 4/10-FNH, 3/10-HCC, 2/10-HMG, 1/10-HiperM, 1/10-HipoM. After being informed about the clinical data 2/10-FNH, 1/10-HCC. II-beginner misdiagnosed: 3/10-FNH; 3/10-HCC, 2/10- HMG, 1/10-HiperM. Unblinded: 1/10-HCC, 1/10- HMG. I-Expert: only 1/10-FNH, 1/10-HCC, 1/10- HMG misdiagnosed. Unblinded: all lesions were correctly diagnosed. II-Expert: 1/10-FNH, 1/10-HCC misdiagnosed. Unblinded: only 1/10-FNH was misdiagnosed. The CAD classifier managed a 75.2% overall correct classification rate. The overall classification before and after the uncovering of clinical data was: I beginner 78 %; 94%, II 82%; 96%. I expert 94%; 100%. II 96%; 98%. CONCLUSIONS The CAD prototype can assist a beginner for a better CEUS diagnostic accuracy. The integration of clinical data in the CAD algorithm is essential. Graphical abstract: Average Intensity variation in Arterial and Late Phase with supra unitary (meaning wash in and sub unitary pattern (meaning washout. REFERENCES 1.Sugimoto K, Shiraishi J, Moriyasu F, Doi K. Computer-aided diagnosis for contrast-enhanced ultrasound in the liver. World J Gastroenterol. 2010;2:215-223. 2. Gatos I, Tsantis S, Spiliopoulos S, Skouroliakou A, Theotokas I

  11. Association of CAD, a multifunctional protein involved in pyrimidine synthesis, with mLST8, a component of the mTOR complexes

    Science.gov (United States)

    2013-01-01

    Background mTOR is a genetically conserved serine/threonine protein kinase, which controls cell growth, proliferation, and survival. A multifunctional protein CAD, catalyzing the initial three steps in de novo pyrimidine synthesis, is regulated by the phosphorylation reaction with different protein kinases, but the relationship with mTOR protein kinase has not been known. Results CAD was recovered as a binding protein with mLST8, a component of the mTOR complexes, from HEK293 cells transfected with the FLAG-mLST8 vector. Association of these two proteins was confirmed by the co-immuoprecipitaiton followed by immunoblot analysis of transfected myc-CAD and FLAG-mLST8 as well as that of the endogenous proteins in the cells. Analysis using mutant constructs suggested that CAD has more than one region for the binding with mLST8, and that mLST8 recognizes CAD and mTOR in distinct ways. The CAD enzymatic activity decreased in the cells depleted of amino acids and serum, in which the mTOR activity is suppressed. Conclusion The results obtained indicate that mLST8 bridges between CAD and mTOR, and plays a role in the signaling mechanism where CAD is regulated in the mTOR pathway through the association with mLST8. PMID:23594158

  12. The simultaneous repression of CCR and CAD, two enzymes of the lignin biosynthetic pathway, results in sterility and dwarfism in Arabidopsis thaliana.

    Science.gov (United States)

    Thévenin, Johanne; Pollet, Brigitte; Letarnec, Bruno; Saulnier, Luc; Gissot, Lionel; Maia-Grondard, Alessandra; Lapierre, Catherine; Jouanin, Lise

    2011-01-01

    Cinnamoyl CoA reductase (CCR) and cinnamyl alcohol dehydrogenase (CAD) catalyze the last steps of monolignol biosynthesis. In Arabidopsis, one CCR gene (CCR1, At1g15950) and two CAD genes (CAD C At3g19450 and CAD D At4g34230) are involved in this pathway. A triple cad c cad d ccr1 mutant, named ccc, was obtained. This mutant displays a severe dwarf phenotype and male sterility. The lignin content in ccc mature stems is reduced to 50% of the wild-type level. In addition, stem lignin structure is severely affected, as shown by the dramatic enrichment in resistant inter-unit bonds and incorporation into the polymer of monolignol precursors such as coniferaldehyde, sinapaldehyde, and ferulic acid. Male sterility is due to the lack of lignification in the anther endothecium, which causes the failure of anther dehiscence and of pollen release. The ccc hypolignified stems accumulate higher amounts of flavonol glycosides, sinapoyl malate and feruloyl malate, which suggests a redirection of the phenolic pathway. Therefore, the absence of CAD and CCR, key enzymes of the monolignol pathway, has more severe consequences on the phenotype than the individual absence of each of them. Induction of another CCR (CCR2, At1g80820) and another CAD (CAD1, At4g39330) does not compensate the absence of the main CCR and CAD activities. This lack of CCR and CAD activities not only impacts lignification, but also severely affects the development of the plants. These consequences must be carefully considered when trying to reduce the lignin content of plants in order to facilitate the lignocellulose-to-bioethanol conversion process.

  13. A computer-aided detection (CAD) system with a 3D algorithm for small acute intracranial hemorrhage

    Science.gov (United States)

    Wang, Ximing; Fernandez, James; Deshpande, Ruchi; Lee, Joon K.; Chan, Tao; Liu, Brent

    2012-02-01

    Acute Intracranial hemorrhage (AIH) requires urgent diagnosis in the emergency setting to mitigate eventual sequelae. However, experienced radiologists may not always be available to make a timely diagnosis. This is especially true for small AIH, defined as lesion smaller than 10 mm in size. A computer-aided detection (CAD) system for the detection of small AIH would facilitate timely diagnosis. A previously developed 2D algorithm shows high false positive rates in the evaluation based on LAC/USC cases, due to the limitation of setting up correct coordinate system for the knowledge-based classification system. To achieve a higher sensitivity and specificity, a new 3D algorithm is developed. The algorithm utilizes a top-hat transformation and dynamic threshold map to detect small AIH lesions. Several key structures of brain are detected and are used to set up a 3D anatomical coordinate system. A rule-based classification of the lesion detected is applied based on the anatomical coordinate system. For convenient evaluation in clinical environment, the CAD module is integrated with a stand-alone system. The CAD is evaluated by small AIH cases and matched normal collected in LAC/USC. The result of 3D CAD and the previous 2D CAD has been compared.

  14. Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

    Science.gov (United States)

    Kim, Tae-Gyung; Kim, Sungtae; Lee, Jae-Hoon

    2016-01-01

    The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n = 40). For ICC (Intraoral, CAD/CAM) group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver) machinable alloy were generated. For IC (Intraoral, Cast) group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM) group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast) group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α = 0.05). The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P 0.05). Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions. PMID:28018914

  15. Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

    Directory of Open Access Journals (Sweden)

    Tae-Gyung Kim

    2016-01-01

    Full Text Available The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n=40. For ICC (Intraoral, CAD/CAM group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver machinable alloy were generated. For IC (Intraoral, Cast group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α=0.05. The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P0.05. Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions.

  16. Present State of CAD Teaching in Spanish Universities

    Science.gov (United States)

    Garcia, Ramon Rubio; Santos, Ramon Gallego; Quiros, Javier Suarez; Penin, Pedro I. Alvarez

    2005-01-01

    During the 1990s, all Spanish Universities updated the syllabuses of their courses as a result of the entry into force of the new Organic Law of Universities ("Ley Organica de Universidades") and, for the first time, "Computer Assisted Design" (CAD) appears in the list of core subjects (compulsory teaching content set by the…

  17. Building Accessible Educational Web Sites: The Law, Standards, Guidelines, Tools, and Lessons Learned

    Science.gov (United States)

    Liu, Ye; Palmer, Bart; Recker, Mimi

    2004-01-01

    Professional education is increasingly facing accessibility challenges with the emergence of webbased learning. This paper summarizes related U.S. legislation, standards, guidelines, and validation tools to make web-based learning accessible for all potential learners. We also present lessons learned during the implementation of web accessibility…

  18. Dipyridamole 201T1 myocardial perfusion tomography and bull's--eye analysis for quantitative evaluation of CAD

    International Nuclear Information System (INIS)

    Jiang Maosong; Tang Xi

    1992-01-01

    To assess the ability of quantitative analysis of dipyridamole 201 T1 tomography for detecting and localizing coronary artery disease (CAD), 55 patients with angiographically proved CAD ( = 50% stenosis) were studied. All patients underwent dipyridamole 201 T1 myocardial perfusion tomography and coronary arteriography. The overall sensitivity for detection of CAD by Bull's-eye analysis was 89% (50 patients) and 92% (51 patients) with visual analysis. The sensitivity for detecting individual vessel involvement with the Bull'-eye analysis was 88% for LAD. 81% for RCA and 67% for LCX. With visual analysis, the results were 88%, 83% and 58% respectively. The overall rate of detection was 87% in lesions greater than or equal to 75% stenosis vs 59% in those under 75% stenosis (P 201 T1 tomography using Bull's-eye display is a highly accurate reproducible technique for the detection of patients with CAD and the localization of individual coronary vessel, and it offers the potential to quantify the percentage of the abnormally perfused myocardium

  19. Manual of engineering drawing to British and international standards

    CERN Document Server

    Simmons, Colin H; Maguire, Dennis E

    2004-01-01

    The Manual of Engineering Drawing has long been recognised as the student and practising engineer's guide to producing engineering drawings that comply with ISO and British Standards. The information in this book is equally applicable to any CAD application or manual drawing. The second edition is fully in line with the requirements of the new British Standard BS8888: 2002, and will help engineers, lecturers and students with the transition to the new standards.BS8888 is fully based on the relevant ISO standards, so this book is also ideal for an international readership. The comprehen

  20. GAMBIT: the global and modular beyond-the-standard-model inference tool

    Science.gov (United States)

    Athron, Peter; Balazs, Csaba; Bringmann, Torsten; Buckley, Andy; Chrząszcz, Marcin; Conrad, Jan; Cornell, Jonathan M.; Dal, Lars A.; Dickinson, Hugh; Edsjö, Joakim; Farmer, Ben; Gonzalo, Tomás E.; Jackson, Paul; Krislock, Abram; Kvellestad, Anders; Lundberg, Johan; McKay, James; Mahmoudi, Farvah; Martinez, Gregory D.; Putze, Antje; Raklev, Are; Ripken, Joachim; Rogan, Christopher; Saavedra, Aldo; Savage, Christopher; Scott, Pat; Seo, Seon-Hee; Serra, Nicola; Weniger, Christoph; White, Martin; Wild, Sebastian

    2017-11-01

    We describe the open-source global fitting package GAMBIT: the Global And Modular Beyond-the-Standard-Model Inference Tool. GAMBIT combines extensive calculations of observables and likelihoods in particle and astroparticle physics with a hierarchical model database, advanced tools for automatically building analyses of essentially any model, a flexible and powerful system for interfacing to external codes, a suite of different statistical methods and parameter scanning algorithms, and a host of other utilities designed to make scans faster, safer and more easily-extendible than in the past. Here we give a detailed description of the framework, its design and motivation, and the current models and other specific components presently implemented in GAMBIT. Accompanying papers deal with individual modules and present first GAMBIT results. GAMBIT can be downloaded from gambit.hepforge.org.