WorldWideScience

Sample records for standard anthropometric measurements

  1. Anthropometric Injury Risk Factors in Elite-standard Youth Soccer

    NARCIS (Netherlands)

    Kemper, G. L. J.; van der Sluis, A.; Brink, M. S.; Visscher, C.; Frencken, W. G. P.; Elferink-Gemser, M. T.

    2015-01-01

    The aim of the study was to investigate whether an increased risk of injury occurrence can be determined through frequent anthropometric measurements in elite-standard youth soccer players. Over the course of one season, we followed 101 male elite-standard youth soccer players between 11 and 19

  2. Regression models for predicting anthropometric measurements of ...

    African Journals Online (AJOL)

    measure anthropometric dimensions to predict difficult-to-measure dimensions required for ergonomic design of school furniture. A total of 143 students aged between 16 and 18 years from eight public secondary schools in Ogbomoso, Nigeria ...

  3. Anthropometric measurements and prevalence of underweight ...

    African Journals Online (AJOL)

    Anthropometric measurements and prevalence of underweight, overweight and obesity in adult Malawians: nationwide population based NCD STEPS survey. ... Introduction: Overweight and obesity are significant causes of increased morbidity and premature mortality from non-communicable diseases, particularly in ...

  4. Anthropometric measurements of children attending a vaccination ...

    African Journals Online (AJOL)

    Background: Growth faltering is a frequent public health problem in children and anthropometric measurements are useful tools for follow-up and early diagnosis. This problem has not been studied in the Cameroonian setting, that\\'s why we undertook this study. Objectives: To have a synopsis of the nutritional status in ...

  5. Anthropometric Measurements Usage in Medical Sciences

    Directory of Open Access Journals (Sweden)

    Nevin Utkualp

    2015-01-01

    Full Text Available Morphometry is introduced as quantitative approach to seek information concerning variations and changes in the forms of organisms that described the relationship between the human body and disease. Scientists of all civilization, who existed until today, examined the human body using anthropometric methods. For these reasons, anthropometric data are used in many contexts to screen for or monitor disease. Anthropometry, a branch of morphometry, is the study of the size and shape of the components of biological forms and their variations in populations. Morphometrics can also be defined as the quantitative analysis of biological forms. The field has developed rapidly over the last two decades to the extent that we now distinguish between traditional morphometrics and the more recent geometric morphometrics. Advances in imaging technology have resulted in the protection of a greater amount of morphological information and have permitted the analysis of this information. The oldest and most commonly used of these methods is radiography. With developments in this area, CT and MRI have also been started to be used in screening of the internal organs. Morphometric measurements that are used in medicine, are widely used in the diagnosis and the follow-up and the treatment of the disease, today. In addition, in cosmetology use of these new measurements is increasing every day.

  6. Anthropometric measurements among four Asian countries in ...

    Indian Academy of Sciences (India)

    Nurul Izzah Abd Rahman

    2018-02-07

    Feb 7, 2018 ... Numerous efforts have been made to establish anthropometric data- base of various population groups, such as students, civil- ian, workers and military recruits [1–5]. These anthropometric data are utilised by the manufacturing community as a guideline in designing products for the global market [6–8].

  7. Anthropometric measurements among four Asian countries in ...

    Indian Academy of Sciences (India)

    Nurul Izzah Abd Rahman

    2018-02-07

    Feb 7, 2018 ... proportions. There are several distinctive anthropometric dimensions that are noticeable when comparisons between ethnic and race groups are made, such as the mean stature and sitting height [11]. The Southeast Asian countries have strong relations and associations in terms of race, culture and history.

  8. Comparison of Different Anthropometric Measurements and Inflammatory Biomarkers

    Directory of Open Access Journals (Sweden)

    Yaron Arbel

    2012-01-01

    Full Text Available Introduction. Different anthropometric variables have been shown to be related to cardiovascular morbidity and mortality. Our aim was to compare the association between different anthropometric measurements and inflammatory status. Methods and results. A cross-sectional study design in which we analyzed the data collected during a five-year period in the Tel Aviv Medical Center Inflammation Survey (TAMCIS. Included in the study were 13,033 apparently healthy individuals at a mean (SD age of 43. Of these, 8,292 were male and 4,741 female. A significant age-adjusted and multiple-adjusted partial correlation was noted between all anthropometric measurements and all inflammatory biomarkers. There was no significant difference in the correlation coefficients between different biomarkers and anthropometric variables. Conclusion. Most of the common used anthropometric variables are similarly correlated with inflammatory variables. The clinician can choose the variable that he/she finds easiest to use.

  9. U.S. Army anthropometric standards for rotary-wing aviators in the light observation helicopter.

    Science.gov (United States)

    Farr, W D; Buescher, T M

    1989-07-01

    U.S. Army anthropometric standards for rotary-wing aviators were examined to determine if the standards allowed an adequate fit of the aviator to the cockpit of the OH-58A "Kiowa" light observation helicopter, which now comprises the overwhelming majority of light helicopters in the active army and reserve forces. Thirty rated aviators with heights less than or equal to 70 in. were examined, and standard anthropometric measurements were made. Army regulations require these measurements on all initial-entry aviation students with heights less than or equal to 68 in. The aviators were then placed in a representative OH-58A cockpit to determine their ability to reach all control surfaces and panel switches. Several aviators greater than 68 in. tall and, therefore, not subject to anthropometric testing upon entry into army aviation, could not perform all cockpit tasks without cockpit changes beyond the limited adjustments in the OH-58A. Several had developed aid devices, especially pads to support forearm-to-thigh "spot welds" to ensure right arm stability on the cyclic control. The same problem was seen with some aviators less than 68 in. in height, who had been anthropometrically evaluated. The present standards do not adequately address functional ability in the OH-58A cockpit, which is the least adjustable cockpit in the combat inventory. Design modifications to accommodate these factors exist and should be used to retrofit existing aircraft and to design future aircrafts.

  10. The relation between bone demineralization, physical activity and anthropometric standards

    Directory of Open Access Journals (Sweden)

    Milena Barbosa Camara

    2017-03-01

    Full Text Available This paper aimed to verify the correlation between bone mineral density and the level of physical activity, as well as the food intake and the anthropometric parameters. It intended to analyse the bone mineral density (BMD of menopausal women through the bone densitometry test (DO in the lumbar region (L1 to L4, femoral neck and total femur, and also use Bouchard’s self-recall of daily activities; employing the food record from Buker and Stuart to dose and quantify the daily intake of calcium and vitamin D. The data were analysed via Kolmogorov-Smirnov’s test, and default value of α = 0.05 was set to compare the BMD averages. It was observed that one hundred percent of the assessed individuals had a BMD level below the average fixed by WHO: 14.4% with osteopenia and 85.6% with osteoporosis; a lower BMD in the femoral area (0.721g and the biggest loss among the sedentary ones (0.698g. It was noticed that there was a correlation between the physical activities and the BMD only when associated with anthropometric standards and the daily ingestion of vitamin D.

  11. Anthropometric Measurements of Children in the Head Start Program.

    Science.gov (United States)

    Bass, William M.; Ferris, M. Scott

    This is a brief preliminary report of an anthropometric measurement study of a group of Head Start children. The areas of primary concern were patterns of tooth eruption and basic head and body dimensions. Permanent Head Start personnel were trained to make the observations and measurements. The sample consisted of 148 children (76 boys, 72 girls)…

  12. Anthropometric measurements of HIV-infected children aged one to ...

    African Journals Online (AJOL)

    2015-10-12

    Oct 12, 2015 ... Abstract: Objectives: To deter- mine the association between HIV infection and anthropometric measures (weight, height, mid- upper arm circumference and head circumference) of children aged one to five years. Method: A cross sectional de- scriptive study using structured questionnaire and measurement ...

  13. changes in body composition and other anthropometric measures

    African Journals Online (AJOL)

    An understanding of the effect of highly active antiretroviral therapy (HAART) on ... Subjects with lower CD4 lymphocyte counts experienced greater increases ... 37 ting in KwaZulu-Natal and to investigate associations between anthropometric measures and CD4 lymphocyte count. METHODS. STUDy pOpULATION.

  14. The effect of maternal anemia on anthropometric measurements of newborns

    International Nuclear Information System (INIS)

    Telatar, Berrin; Comert, Serdar; Vitrinel, Ayca; Akin, Yasemin; Erginoz, Ethem

    2009-01-01

    To evaluate the relation between maternal prenatal hemoglobin concentration and neonatal anthropometric measurements. All pregnant women who gave birth at the Obstetrics Department of Dr. LK Kartal Training and Research Hospital, Istanbul, Turkey, from January 1, 2005 to December 31, 2006, and their newborns were included in this prospective, cross-sectional study. The newborns weight, height, head, and chest circumference were recorded. Mothers with hemoglobin concentration less than 11g/dl were evaluated as anemic. The anemic mothers were then grouped into 3 categories according to the corresponding hemoglobin concentration: mild (10.9-9.0g/dl), moderate (8.9-7.0 g/dl), and severe anemic (less than 7 g/dl). The anthropometric measurements of newborns from non-anemic and anemic mother groups were compared. Of the 3688 pregnant women, 1588 (43%) were found to be anemic. Among the anemic mothers, 1245 had mild (78.5%), 311 had moderate (19.5%), and 32 (2%) had severe anemia. The anthropometric measurements (height, weight, head and chest circumference) of newborns of anemic and non-anemic mother groups showed a statistically significant difference (p=0.036, p=0.044, p=0.013, and p=0.0002). There was a statistically significant difference in height, weight, and chest circumference of newborns of severe anemic and mild anemic mothers (p=0.017, p=0.008 and p=0.02). The height (1.1 cm), weight (260 g), head (0.42 cm), and chest (1 cm) circumference of neonates in the severe anemic group is less than the mild anemic group. Anemia during pregnancy affect the anthropometric measurements of a newborn. Severe anemia had significant negative effect on neonatal anthropometric measurements. (author)

  15. Three-Dimensional Anthropometric Database of Attractive Caucasian Women: Standards and Comparisons.

    Science.gov (United States)

    Galantucci, Luigi Maria; Deli, Roberto; Laino, Alberto; Di Gioia, Eliana; D'Alessio, Raoul; Lavecchia, Fulvio; Percoco, Gianluca; Savastano, Carmela

    2016-10-01

    The aim of this paper is to develop a database to determine a new biomorphometric standard of attractiveness. Sampling was carried out using noninvasive three-dimensional relief methods to measure the soft tissues of the face. These anthropometric measurements were analyzed to verify the existence of any canons with respect to shape, size, and measurement proportions which proved to be significant with regard to the aesthetics of the face. Finally, the anthropometric parameters obtained were compared with findings described in the international literature.The study sample was made up competitors in the Miss Italy 2010 and 2009 beauty contest. The three-dimensional (3D) scanning of soft tissue surfaces allowed 3D digital models of the faces and the spatial 3D coordinates of 25 anthropometric landmarks to be obtained and used to calculate linear and angular measurements. A paired Student t test for the analysis of the means allowed 3 key questions in the study of biomorphometric parameters of the face to be addressed through comparison with the data available in the literature.The question of statistical evidence for the samples analyzed being members of the populations samples reported in literature was also addressed.The critical analysis of the data helped to identify the anthropometric measurements of the upper, middle, and lower thirds of the face, variations in which have a major influence on the attractiveness of the face. These changes involve facial width, height, and depth. Changes in measurements of length, angles, and proportions found in the sample considered were also analyzed.

  16. Harmonization process and reliability assessment of anthropometric measurements in the elderly EXERNET multi-centre study.

    Science.gov (United States)

    Gómez-Cabello, Alba; Vicente-Rodríguez, Germán; Albers, Ulrike; Mata, Esmeralda; Rodriguez-Marroyo, Jose A; Olivares, Pedro R; Gusi, Narcis; Villa, Gerardo; Aznar, Susana; Gonzalez-Gross, Marcela; Casajús, Jose A; Ara, Ignacio

    2012-01-01

    The elderly EXERNET multi-centre study aims to collect normative anthropometric data for old functionally independent adults living in Spain. To describe the standardization process and reliability of the anthropometric measurements carried out in the pilot study and during the final workshop, examining both intra- and inter-rater errors for measurements. A total of 98 elderly from five different regions participated in the intra-rater error assessment, and 10 different seniors living in the city of Toledo (Spain) participated in the inter-rater assessment. We examined both intra- and inter-rater errors for heights and circumferences. For height, intra-rater technical errors of measurement (TEMs) were smaller than 0.25 cm. For circumferences and knee height, TEMs were smaller than 1 cm, except for waist circumference in the city of Cáceres. Reliability for heights and circumferences was greater than 98% in all cases. Inter-rater TEMs were 0.61 cm for height, 0.75 cm for knee-height and ranged between 2.70 and 3.09 cm for the circumferences measured. Inter-rater reliabilities for anthropometric measurements were always higher than 90%. The harmonization process, including the workshop and pilot study, guarantee the quality of the anthropometric measurements in the elderly EXERNET multi-centre study. High reliability and low TEM may be expected when assessing anthropometry in elderly population.

  17. Harmonization Process and Reliability Assessment of Anthropometric Measurements in the Elderly EXERNET Multi-Centre Study

    Science.gov (United States)

    Gómez-Cabello, Alba; Vicente-Rodríguez, Germán; Albers, Ulrike; Mata, Esmeralda; Rodriguez-Marroyo, Jose A.; Olivares, Pedro R.; Gusi, Narcis; Villa, Gerardo; Aznar, Susana; Gonzalez-Gross, Marcela; Casajús, Jose A.; Ara, Ignacio

    2012-01-01

    Background The elderly EXERNET multi-centre study aims to collect normative anthropometric data for old functionally independent adults living in Spain. Purpose To describe the standardization process and reliability of the anthropometric measurements carried out in the pilot study and during the final workshop, examining both intra- and inter-rater errors for measurements. Materials and Methods A total of 98 elderly from five different regions participated in the intra-rater error assessment, and 10 different seniors living in the city of Toledo (Spain) participated in the inter-rater assessment. We examined both intra- and inter-rater errors for heights and circumferences. Results For height, intra-rater technical errors of measurement (TEMs) were smaller than 0.25 cm. For circumferences and knee height, TEMs were smaller than 1 cm, except for waist circumference in the city of Cáceres. Reliability for heights and circumferences was greater than 98% in all cases. Inter-rater TEMs were 0.61 cm for height, 0.75 cm for knee-height and ranged between 2.70 and 3.09 cm for the circumferences measured. Inter-rater reliabilities for anthropometric measurements were always higher than 90%. Conclusion The harmonization process, including the workshop and pilot study, guarantee the quality of the anthropometric measurements in the elderly EXERNET multi-centre study. High reliability and low TEM may be expected when assessing anthropometry in elderly population. PMID:22860013

  18. Can foot anthropometric measurements predict dynamic plantar surface contact area?

    Directory of Open Access Journals (Sweden)

    Collins Natalie

    2009-10-01

    Full Text Available Abstract Background Previous studies have suggested that increased plantar surface area, associated with pes planus, is a risk factor for the development of lower extremity overuse injuries. The intent of this study was to determine if a single or combination of foot anthropometric measures could be used to predict plantar surface area. Methods Six foot measurements were collected on 155 subjects (97 females, 58 males, mean age 24.5 ± 3.5 years. The measurements as well as one ratio were entered into a stepwise regression analysis to determine the optimal set of measurements associated with total plantar contact area either including or excluding the toe region. The predicted values were used to calculate plantar surface area and were compared to the actual values obtained dynamically using a pressure sensor platform. Results A three variable model was found to describe the relationship between the foot measures/ratio and total plantar contact area (R2 = 0.77, p R2 = 0.76, p Conclusion The results of this study indicate that the clinician can use a combination of simple, reliable, and time efficient foot anthropometric measurements to explain over 75% of the plantar surface contact area, either including or excluding the toe region.

  19. Sonographic Measurement of the Umbilical Cord and Its Vessels and Their Relation with Fetal Anthropometric Measurements

    Science.gov (United States)

    Rostamzadeh, Sheida; Kalantari, Mojgan; Shahriari, Mona; Shakiba, Madjid

    2015-01-01

    Background: It has been established that presence of lean umbilical cord with reduced Wharton’s jelly in sonographic scans is a fetal marker for risk of small for gestational age at birth. With improvement of ultrasound techniques, more studies have been investigating the alterations of the umbilical cord on pregnancy outcomes. Objectives: To determine the reference ranges of the umbilical cord area during pregnancy and to find out the association between umbilical cord morphometry and fetal anthropometric measurements. Patients and Methods: A cross sectional study was carried out on a study population of 278 low-risk pregnant women between 15 and 41 weeks of gestational age. Fetal anthropometric measurements including biparietal diameter, abdominal circumference, and femur length were calculated. The measurements of the cross-sectional area (CSA) and circumference of the umbilical cord, vein and arteries were done on an adjacent plane to the insertion of umbilical cord into the fetus’s abdomen. The mean and standard deviation of the CSA of the umbilical cord and the 5th, 10th, 50th, 90th, 95th percentiles of it were calculated for each gestational age. Pearson correlation coefficient was used to assess the correlation between the measures of the cord and fetal anthropometric measurements. Polynomial regression analysis was performed for curves. Results: The values of the CSA of the umbilical cord, umbilical vein and Wharton’s jelly (WJ) increase consistently until 30 weeks of gestation, after which they reach a plateau. There was a significant correlation between anthropometric measurements and umbilical cord measurements especially with the CSA of the umbilical cord, umbilical vein and WJ. The regression equation for the umbilical cord CSA according to gestational age up to 30 weeks was y = -0.2159 x2 + 23.828x-325.59 (R2 = 0.6334) and for the WJ area according to gestational age up to 30 weeks, it was y = -0.2124 x 2 +17.613x-221.66 (R2 = 0

  20. Correlation between several anthropometric measurements to birth weight

    Directory of Open Access Journals (Sweden)

    Muhammad Nur

    2001-12-01

    Full Text Available Perinatal mortality remains one of the factors leading to child mortality, even for crude death as a whole. Therefore, good perinatal care is considered to be useful for reducing this mortality. Low birth weight is one of neonatal morbidity cause; previous studies reported correlation between birth weight to several anthropometric measurements and their predictive value. We aimed to evaluate the correlation between birth length, head, chest, abdominal, calf and mid arm circumferences as well as to foot length to birth weight. A cross sectional study was conducted in Adam Malik Hospital Medan between November 1st 1998 to January 31st 1999. All babies without clear moulage, caput succedaneum or cephal hematoma were studied. Birth weight was measured by TANITA weighing scale within the first 24 hours after delivery. Birth length by somatometer and head, chest, abdominal, calf and mid arm circumferences as well as foot length were measured 3 times by using plastic measuring tape. It was evident a positive correlation of birth weight to all such anthropometric measurements with the highest correlation coefficient for calf circumference (r : 0.92. Calf circumference of 9,8 cm is predictor of low birth weight.

  1. Adipocytokines and anthropometric measures in type 2 diabetics.

    Science.gov (United States)

    Harke, Shubhangi M; Khadke, Suresh P; Ghadge, Abhijit A; Manglekar, Ashwini S; Shah, Shashank S; Diwan, Arundhati G; Kuvalekar, Aniket A

    2017-11-01

    Type 2 diabetes mellitus has assumed pandemic proportions worldwide. Aggressive management of hyperglycemia in diabetics is a primary goal of treatment. We have previously reported favorable effects of oral hypoglycemic agents on adipocytokines. Aim of the present study was to investigate the relationship of adipocytokines with anthropometric measures and biochemical parameters in type 2 diabetics. Clinically diagnosed type 2 diabetics and age, gender matched healthy volunteers were recruited for study. Anthropometric measurements like height, weight, waist-circumference, hip-circumference were recorded and BMI, waist-hip ratio were calculated. Fasting blood samples were collected from participants and sera were analyzed for glucose, glycated haemoglobin, total cholesterol, SGOT, SGPT, insulin, adiponectin and leptin. Correlation of adipocytokines with anthropometric and biochemical parameters was assessed in healthy and diabetic individuals. BMI and WHR in diabetics were significantly higher than healthy population. BMI did not show significant association with adipocytokines. Diabetic males with WHR≥0.9 showed negative association with adiponectin and positive association with leptin. WC did not show significant association with adipocytokines in males. Irrespective of WC, healthy females exhibited positive association with leptin. Diabetic females with WC≥88cm showed leptin to be positively associated with WC. Such association of adipocytokines with WHR was not detected in females. Body fat distribution can be considered as a parameter in assessing adipokine imbalance. Central adiposity is a better measure of adipokine imbalance than BMI. Abdominal obesity in diabetics correlates with altered levels of adipocytokines indicating its importance in diabetic individuals. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  2. Mismatch between classroom furniture and anthropometric measures in Chilean schools.

    Science.gov (United States)

    Castellucci, H I; Arezes, P M; Viviani, C A

    2010-07-01

    Children spend about five hours per day sitting down while doing their school work. Considering this as well as the potential inadequate use of school furniture, it is likely that some anatomical-functional changes and problems in the learning process may occur. The aim of this study was to compare furniture sizes within three different schools with the anthropometric characteristics of Chilean students in the Valparaíso region, in order to evaluate the potential mismatch between them. The sample consisted of 195 volunteer students (94 male, 101 female) of the 8th grade, ranging from 12.5 to 14.5 years of age from 3 different schools. Regarding the methodology, 6 anthropometric measures (Stature, Popliteal height, Buttock-popliteal length, Elbow height while sitting, Hip width, Thigh thickness and Subscapular height) were gathered, as well as 8 dimensions from the school furniture. For the evaluation of classroom furniture a match criterion equation was defined. After considering the existing classroom furniture dimensions in each match criterion equation, the anthropometric characteristics of the considered population were compared in order to determine the mismatch between them. Results indicated that seat height, which should be considered as the starting point for the design of classroom furniture, was appropriate for students' popliteal height in only 14% of the 2 out of the 3 schools, and 28% in the third. Seat to desk height was too high and mismatched 99% of the students in one school and 100% in the others. Therefore, it was possible to conclude that the classroom's furniture was inadequate in almost all the analyzed cases and subjects. It is possible that the high mismatch percentage found between furniture and students' anthropometry can be associated to the fact that the acquisition and selection of the furniture was made without any ergonomic concern or criteria. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. Anthropometric measurements for ergonomic design of students’ furniture in India

    Directory of Open Access Journals (Sweden)

    Ismail Wilson Taifa

    2017-02-01

    Full Text Available This paper presents anthropometric measurements regarding engineering students in India. Health survey (ergonomic assessment was carried out to know the health status of all students who have been using poorly designed furniture. The data were measured with the help of various tools. After data collection and analysis, authors came up with exhaustive dimensions for designing adjustable classrooms furniture. Dimensions recommended include; bench surface height, bench depth and width, back rest width and height, backrest angle, desk height, desk depth, width, and desk angle. Therefore, an implementation of these data will help to create comfortability, safety, well-being, suitability, reduce Musculoskeletal disorders, and improve performance of students in terms of attentiveness. Also, it is highly recommended to consider requirements from students in designing classrooms furniture and conduct seminar or workshop to educate students regarding the negative impact towards adapting poor posture in the long usage of classrooms furniture.

  4. Application of alternative anthropometric measurements to predict metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Gul Sagun

    2014-01-01

    Full Text Available OBJECTIVE: The association between rarely used anthropometric measurements (e.g., mid-upper arm, forearm, and calf circumference and metabolic syndrome has not been proven. The aim of this study was to assess whether mid-upper arm, forearm, calf, and waist circumferences, as well as waist/height ratio and waist-to-hip ratio, were associated with metabolic syndrome. METHODS: We enrolled 387 subjects (340 women, 47 men who were admitted to the obesity outpatient department of Istanbul Medeniyet University Goztepe Training and Research Hospital between September 2010 and December 2010. The following measurements were recorded: waist circumference, hip circumference, waist/height ratio, waist-to-hip ratio, mid-upper arm circumference, forearm circumference, calf circumference, and body composition. Fasting blood samples were collected to measure plasma glucose, lipids, uric acid, insulin, and HbA1c. RESULTS: The odds ratios for visceral fat (measured via bioelectric impedance, hip circumference, forearm circumference, and waist circumference/hip circumference were 2.19 (95% CI, 1.30-3.71, 1.89 (95% CI, 1.07-3.35, 2.47 (95% CI, 1.24-4.95, and 2.11(95% CI, 1.26-3.53, respectively. The bioelectric impedance-measured body fat percentage correlated with waist circumference only in subjects without metabolic syndrome; the body fat percentage was negatively correlated with waist circumference/hip circumference in the metabolic syndrome group. All measurements except for forearm circumference were equally well correlated with the bioelectric impedance-measured body fat percentages in both groups. Hip circumference was moderately correlated with bioelectric impedance-measured visceral fat in subjects without metabolic syndrome. Muscle mass (measured via bioelectric impedance was weakly correlated with waist and forearm circumference in subjects with metabolic syndrome and with calf circumference in subjects without metabolic syndrome. CONCLUSION: Waist

  5. Measuring the Reliability of Sagittal Facial Anthropometric Measurements under Soft Tissue Displacement Using a Modified Ruler

    Directory of Open Access Journals (Sweden)

    Faramarz Mojtahedzadeh

    2013-01-01

    Full Text Available Objective: Despite the current use of radiography for quantifying sagittal skeletal measurements, it is an unsuitable way for screening or epidemiologic purposes. Although not fully approved, anthropometric measurements have been suggested as a substitute, and considering displacement of soft tissues, could possibly lead to more consistent results. The purpose of this study was to evaluate the reliability of anthropometric anteroposterior facial measurements under soft tissue compression using a special ruler.Material and Methods: Anthropometric measurements were done with a specifically designed sliding ruler twice on 36 adult patients with a 14 day lag between two measurements. The ruler measured the distance between the external acoustic meatus and the nasion (Na, subnasal (Sn point and the soft tissue pogonion (Pog. The soft tissue was displaced during measurements only to the extent that the underlying hard tissue resistance was felt subjectively by each assessor. The intraclass correlation coefficient (ICC was calculated for both inter- and intra- rater measurements using SPSS software.Results: All measurements had inter- and intrarater agreements above 0.9, with only a few parameters having lower bound confidence intervals below 0.9, but more than 0.8.Conclusion: Sagittal facial anthropometric measurements under soft tissue displacement using the specific ruler are valid and reliable and could possibly aid orthodontists in chairside craniofacial assessments.

  6. Evaluation of positional plagiocephaly: Conventional anthropometric measurement versus laser scanning method.

    Science.gov (United States)

    Nahles, Susanne; Klein, Martin; Yacoub, Anke; Neyer, Julia

    2018-01-01

    The incidence of plagiocephaly has increased in the 25 years since the "Back to Sleep" campaign in 1991 to prevent sudden infant death. Plagiocephaly is not considered to be a pathological condition. It is more of an esthetic impairment and could have potentially negative psychological or psychosocial consequences; therefore, treatment is recommended. The aim of this study is to compare conventional anthropometry and laser scanning - two different measurement methods - as diagnostic instruments for plagiocephaly. The present study also tests the measurement time of both methods and whether one method is easier on the patient than the other. A total of 44 children (21 girls, 23 boys) with a mean age of 8.8 months were involved in the present study. Of all patients, the following parameters were routinely evaluated using a standard protocol with the conventional anthropometric method and the scan method: head circumference, head length, head width, head diagonals, and distances ex-t. Furthermore, the time required to obtain measurements and the behavior of the children during measurement were documented. For statistical analysis, a t-test and a Wilcoxon test were used to analyze differences between the two methods. The results for head circumference showed a mean of 441.5 mm for the anthropometric measurements and 441.6 mm for the scan method, with no significant difference between the two methods. A significant difference was found regarding the head width, head length, diagonals, and distance ex-t. The measurement process using the scan method needed a mean of 579.6 s in contrast to the manual anthropometric method, which required a mean time of 180.5 s. In comparison with the conventional anthropometric method, measurements made with a 3D laser scanner yield inconsistent results. Moreover, the current state of technology of 3D cephalometry has no advantages compared with the conventional anthropometric method. Disadvantages worth mentioning appear to be the

  7. ANTHROPOMETRIC MEASUREMENT OF PRIMARY SCHOOL GOING CHILDREN IN KARACHI

    Directory of Open Access Journals (Sweden)

    Kashmala Khan

    2016-04-01

    Full Text Available Background: Children were major part of our society and their health issues were too much, so it’s necessary that child should b healthy so their health assessment is important worldwide the acceptable method for assessment of health status is anthropometry (weight & height. This study was done to assess the anthropometric measurement of primary school going children of Karachi, sindh Pakistan, and evaluate how much students were underweight. Methods: The study was done in different primary school of Karachi including private semiprivate and government. The study design was cross sectional study. The sample size of our study was 240, including both genders male& female with range between 7-12 years. Result: The result shows that 34.9% were underweight (below 5th percentile, 63.44% were normal weight (between 5-95th percentile and only0.8% overweight (above 95th percentile.The result showed male-female ratio was 51.5% boys and 48.5% were underweight. The prevalence of underweight in private sector was only 9.5% but in government it was 45.5%.The height of student also calculated and 26.3% children were below the 5th percentile of height for the age, 62.8% were between 5th to 95th percentile and 10.9% above 95thpercentile. Conclusion: The prevalence of underweight in primary school going children in Karachi shows the dietary requirements of children are not fulfilled properly and this may lead to many sever pathological conditions, so it is necessary to take positive steps regarding awareness of proper diet, hygiene and growth & development of child.

  8. NEWBORN CONDITION AND ANTHROPOMETRIC MEASURES IN BABY FRIENDLY PROGRAM

    Directory of Open Access Journals (Sweden)

    Momcilo Djordjevic

    2008-01-01

    Full Text Available Mother’s breast milk is the best product that the new born infant could be fed with. It contains nutritious matters necessary for growth and progress of the new born infants, ideally adapted for the baby. This is not only the food. It provides the support for protection against infections.The aim of the investigation was to establish whether the newborn condition right after the birth and anthropometric measures affect entering the baby friendly program. The study was conducted during 2003 in OGC CC Kragujevac and included 216 new born infants included in baby friendly program and 216 new born infants outside the program.The following parameters in newborn infants were observed: Apgar score, body mass, body length, head circumference.Significantly most often in both examined groups (73 up to 75%, the value of Apgar score of the new born infants was in the interval 9 – 10 and it did not affect the selection into baby friendly program.New born infants from baby friendly program statistically had significantly greater weight than the infants outside the program-on average for about 80 g. The greater weight positively affects entering the baby friendly program.Body length and infant head circumference did not statistically significantly differed between the examined groups.Statistically important difference in body mass can be justified by higher surveillance of pregnant women from the program. The treatment should reflect in controlled nourishment, avoidance of all harmful causes like consumption of cigarettes and alcoholic drinks, which are proven risks for the newborn infants from such pregnancies to have lesser body mass. The advantage of greater body mass lies in the fact that after the childbirth, the relative loss of the body weight is lesser compared to the infants outside the program.

  9. Rapid weight gain during infancy and early childhood is related to higher anthropometric measurements in preadolescence.

    Science.gov (United States)

    Nanri, H; Shirasawa, T; Ochiai, H; Nomoto, S; Hoshino, H; Kokaze, A

    2017-05-01

    This study examined the relationship between rapid weight gain during infancy and/or early childhood and anthropometric measurements [body mass index (BMI), percent body fat (%BF), waist circumference (WC) and waist-to-height ratio (WHtR)] in preadolescence by sex. Subjects were fourth-grade school children (aged 9 to 10 years) from elementary schools in Ina-town, Japan, in 2010. Measurements of height, weight, %BF and WC were conducted for each subject. We obtained data on height and weight of subjects at birth, age 1.5 years and age 3 years from the Maternal and Child Health handbook. Rapid weight gain was defined as a change in weight-for-age standard deviation score greater than 0.67 from birth to age 1.5 years (infancy) or from age 1.5 to 3 years (early childhood). All anthropometric variables (BMI, %BF, WC and WHtR) at age 9 to 10 years were significantly higher in the rapid weight gain during both infancy and early childhood period group than in the no rapid weight gain group, regardless of sex. When compared with the no rapid weight gain group, rapid weight gain during early childhood period had significantly higher BMI and WC in boys and BMI, %BF and WC in girls. Compared with the no rapid weight gain group, the rapid weight gain during infancy group had a significantly higher WC in boys and significantly higher BMI and WC in girls. Rapid weight gain during both infancy and early childhood was related to higher anthropometric measurements, including WHtR, among Japanese preadolescents, regardless of sex. This study suggests that rapid weight gain during infancy and early childhood may be a risk factor for general/abdominal obesity later in life. © 2017 The Authors. Child: Care, Health and Development Published by John Wiley & Sons Ltd.

  10. Association between anthropometric measures of obesity and subclinical atherosclerosis in Bangladesh.

    Science.gov (United States)

    Ge, Wenzhen; Parvez, Faruque; Wu, Fen; Islam, Tariqul; Ahmed, Alauddin; Shaheen, Ishrat; Sarwar, Golam; Demmer, Ryan T; Desvarieux, Moise; Ahsan, Habibul; Chen, Yu

    2014-01-01

    Anthropometric measures such as waist-hip-ratio (WHR), waist-height-ratio (WHtR), waist circumference, Mid-upper arm circumference (MUAC), and upper thigh circumference, have been linked to the risk of cardiovascular disease (CVD). However, their relationships with subclinical atherosclerosis are unclear. Studies in normal-weight populations, especially in Asian countries where leanness is prevalent, are lacking. We conducted a cross-sectional study to assess the associations of WHR, WHtR, waist circumference, hip circumference, body mass index (BMI), MUAC and upper thigh circumference with carotid intima-media thickness (cIMT) among 562 middle-aged participants free of CVD in rural Bangladesh. After adjusting for age and sex, WHR and waist circumference but not BMI showed a positive significant association with cIMT. In multivariate analysis, each standard deviation (SD) increase of WHR (0.08) or WHtR (0.07) was associated with an 8.96 μm (95% CI, 1.12-16.81) or 11.45 μm (95%CI, 0.86-22.04) difference in cIMT, respectively, after controlling for age, sex, BMI, smoking status, education level, and systolic blood pressure (SBP). The associations of WHR and WHtR with cIMT were independent of the influence of other anthropometric measures. The associations of other anthropometric measures and cIMT were not apparent. In our relatively lean, healthy Asian population, WHR and WHtR appear to be better predictors of early atherosclerosis than other common surrogates of adiposity. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Anthropometric Measurements and Dental Caries in Children: A Systematic Review of Longitudinal Studies123

    Science.gov (United States)

    Li, Ling-Wei; Wong, Hai Ming; Peng, Si-Min; McGrath, Colman P

    2015-01-01

    There is growing interest in the association between anthropometric measurements and dental caries in childhood over time (life-course studies). The aim of this review was to identify and systematically review the evidence of the association between anthropometric measurements and dental caries in childhood over time. PubMed, Institute for Scientific Information (ISI) Web of Knowledge, the Cochrane Library, and 6 other databases were searched to identify effective articles. A systematic approach involving critical appraisal was conducted to examine the relation between anthropometric measurements and dental caries in preschool- and school-aged populations from longitudinal studies. An initial search identified 1338 studies, with 59 potentially effective studies (κ = 0.82) and 17 effective studies (κ = 0.88). The quality of reporting among the studies ranged from 19.5 to 30.0 according to the Strengthening the Reporting of Observational studies in Epidemiology (STROBE) criteria. Among the effective studies, 2 studies in which caries was used to predict anthropometric measurements consistently found an inverse association and 15 studies in which anthropometric measurements were used to predict caries were inconsistent, with results appearing to be influenced by nonuniformity of assessments, setting, and procedure of measurements; age and ethnicity of participants; and confounders of dental caries. In conclusion, among >1000 studies identified, 17 informed this systematic review. The quality of reporting of these studies varied considerably. Evidence of the association between anthropometric measurements and dental caries is conflicting and remains inconclusive. PMID:25593143

  12. Association between masticatory performance and anthropometric measurements and nutritional status in the elderly.

    Science.gov (United States)

    Okada, Kiwako; Enoki, Hiromi; Izawa, Sachiko; Iguchi, Akihisa; Kuzuya, Masafumi

    2010-01-01

    The association between chewing ability and physical constitution and nutritional status remains uncertain in the elderly. We examined the relationships between chewing ability and anthropometric measurements or nutritional status in the elderly. A total of 200 subjects (78 men and 122 women; mean age +/- standard deviation, 76.6 +/- 7.1) were enrolled from geriatric clinical settings. Chewing ability was evaluated by color-changeable chewing gum. Bodyweight, body mass index, mid-upper-arm circumference (MAC), and triceps skinfold, grip strength, serum albumin, physical and cognitive functions, depressive status, and dental status were determined. Correlations were found between chewing ability and bodyweight, MAC, dental status, physical and cognitive functions, and depressive status after adjusting for age and sex. The concentrations of serum albumin were well-correlated with chewing ability and anthropometric measurements. Stepwise linear regression analyses revealed that the masticatory cycle, dental status, bodyweight and MAC are predictors of chewing ability, and that age, chewing ability, grip strength and sex are predictors of serum albumin concentrations. Chewing ability is associated with not only oral health status but also the physical constitution of the elderly. In addition, chewing ability may add to the regulation of the nutritional status in the elderly.

  13. Different anthropometric adiposity measures and their association with cardiovascular disease risk factors: a meta-analysis

    OpenAIRE

    van Dijk, S. B.; Takken, T.; Prinsen, E. C.; Wittink, H.

    2012-01-01

    Objectives To investigate which anthropometric adiposity measure has the strongest association with cardiovascular disease (CVD) risk factors in Caucasian men and women without a history of CVD. Design Systematic review and meta-analysis. Methods We searched databases for studies reporting correlations between anthropometric adiposity measures and CVD risk factors in Caucasian subjects without a history of CVD. Body mass index (BMI), waist circumference, waist-to-hip ratio, waist-to-height ra...

  14. Height and Weight Estimation From Anthropometric Measurements Using Machine Learning Regressions.

    Science.gov (United States)

    Rativa, Diego; Fernandes, Bruno J T; Roque, Alexandre

    2018-01-01

    Height and weight are measurements explored to tracking nutritional diseases, energy expenditure, clinical conditions, drug dosages, and infusion rates. Many patients are not ambulant or may be unable to communicate, and a sequence of these factors may not allow accurate estimation or measurements; in those cases, it can be estimated approximately by anthropometric means. Different groups have proposed different linear or non-linear equations which coefficients are obtained by using single or multiple linear regressions. In this paper, we present a complete study of the application of different learning models to estimate height and weight from anthropometric measurements: support vector regression, Gaussian process, and artificial neural networks. The predicted values are significantly more accurate than that obtained with conventional linear regressions. In all the cases, the predictions are non-sensitive to ethnicity, and to gender, if more than two anthropometric parameters are analyzed. The learning model analysis creates new opportunities for anthropometric applications in industry, textile technology, security, and health care.

  15. Anthropometric Measurements of Preschool Children in North Cameroon

    OpenAIRE

    Chiabi, Andreas; Nem, Danièle; Kobela, Marie; Mbuagbaw, Lawrence; Obama, Marie-Therese; Ekoe, Tetanye

    2013-01-01

    Abstract. Nearly 30% of the world’s population is currently suffering from one or more of the many forms of malnutrition. In Cameroon, 32% of under-five children suffer from moderate and chronic under nutrition, and 13% from the severe chronic form.    This study aimed at evaluating the nutritional status of preschool children using anthropometric indices and the relationship of these to the mothers’ socioeconomic status in a regional setting in Cameroon. It was a cross sectional, descriptive...

  16. Standards for holdup measurement

    International Nuclear Information System (INIS)

    Zucker, M.S.

    1982-01-01

    Holdup measurement, needed for material balance, depend intensively on standards and on interpretation of the calibration procedure. More than other measurements, the calibration procedure using the standard becomes part of the standard. Standards practical for field use and calibration techniques have been developed. While accuracy in holdup measurements is comparatively poor, avoidance of bias is a necessary goal

  17. Anthropometric measurements of students athletes in relation to physically inactive students

    Directory of Open Access Journals (Sweden)

    Namik Trtak

    2012-04-01

    Full Text Available Introduction: Anthropometry is a method of anthropology that refers to the measuring and testing the human body and to the relationship between the size of its individual parts.The task of anthropometry is as accurately as possible quantitatively characterize the morphological features of the human body.Measurements are made due to the anthropometric points which can be: fixed (standard on the site of prominence and virtual (change due to the bodyposition. Goals of research: To evaluate the impact of basketball on the growth and development of seventeen years old adolescents and prevention of deformities of the spinal column and chest.Methods: The study included 40 respondents. Criteria for inclusion: male respondents aged 17 years who played basketball for more than one year, male respondents aged 17 years who are physically inactive. Criteria for exclusion: female respondents, respondents who played basketball for less than one year, respondents who are engaged in some other sport professionally or recreationally, respondents younger and olderthan 17 years. In the study,there were made measurements of thorax scope in the axillary and mamilar level, measurements of body weight and height and measurements of Body mass index.Results of research: Out of 40 respondents 20 are basketball players and 20 physically inactive. Compared to the average value between the two groups of respondents certain differences were observed, which aremost noticeable in body weight (basketball players had more weigh about, 5 kg on average and height (basketball players are taller, about 7 cm on average. During the anthropometric measurements of thoraxdeformities of the spinal column have been observed which affect the deformation of the thorax. Of the 20 players one has a deformity of the spinal column, and out of the same number of physically inactive studentseven 12 have deformed spine.Conclusion: Basketball has a positive effect on the proper growth and development

  18. Anthropometric measures change and quality of life in elderly people: a longitudinal population-based study in Southern Brazil.

    Science.gov (United States)

    Tessari, Ana Aparecida; Giehl, Maruí Weber Corseuil; Schneider, Ione Jayce Ceola; González-Chica, David Alejandro

    2016-12-01

    To analyze the effects of anthropometric measures change on quality of life (QoL) in elderly, using measured anthropometric data on body mass index (BMI) and waist circumference (WC). Population-based cohort study investigating a sample of elderly (≥60) assessed in 2009 (n = 1705) and followed up in 2013 (n = 1197). QoL was evaluated in 2013 using the CASP-19. Variables evaluated as exposure including BMI and WC in 2009 (both standardized), categories of anthropometric measures change from 2009 to 2013 (excess weight = BMI ≥ 25.0 kg/m 2 ; large WC = top quartile), and the absolute BMI and WC change in same period. Multivariate linear regressions adjusted for possible confounding factors and mediators were used. Both BMI and WC at baseline were associated with lower QoL scores, even after adjustment for confounding variables (β BMI  = -0.9; 95 % CI -1.5; -0.3 and β WC  = -1.0; 95 % CI -1.7; -0.4). Additionally, QoL scores were lower among elderly with excess weight (β = -1.4; 95 % CI -2.9; 0.0) or large WC (β = -3.3; 95 % CI -5.2; -1.4) in both waves than among those whose BMI and WC were always normal, but changes in anthropometric measures did not affect QoL. The presence of chronic diseases was a partial mediator of these associations, especially for effects of BMI change. Anthropometric measures change treated as a continuous variable was not associated with QoL. Having excess weight and large WC in both waves was associated with lower QoL scores in elderly, but changing the anthropometric measures did not affect this outcome. Maintaining weight and WC within normal limits during aging can help to preserve QoL.

  19. Predicting intra-abdominal fatness from anthropometric measures : the influence of stature

    NARCIS (Netherlands)

    Han, T.S.; McNeill, G; Seidell, J C; Lean, M.E.J.

    OBJECTIVE: To investigate the influence of height on the relationships between the intra-abdominal fat and anthropometric measures. SUBJECTS: Twenty healthy female volunteers aged 20-51 y from Aberdeen, and 71 men and 34 women aged 19-85 y from Nijmegen, The Netherlands. OUTCOME MEASURES:

  20. Absence of disparities in anthropometric measures among Chilean indigenous and non-indigenous newborns

    Science.gov (United States)

    2010-01-01

    Background Studies throughout North America and Europe have documented adverse perinatal outcomes for racial/ethnic minorities. Nonetheless, the contrast in newborn characteristics between indigenous and non-indigenous populations in Latin America has been poorly characterized. This is due to many challenges, including a lack of vital registration information on ethnicity. The objective of this study was to analyze trends in anthropometric measures at birth in Chilean indigenous (Mapuche) and non-indigenous children over a 5-year period. Methods We examined weight and length at birth using information available through a national data base of all birth records for the years 2000 through 2004 (n = 1,166.513). Newborns were classified ethnically according to the origins of the parents' last names. Result The average birthweight was stable over the 5 year period with variations of less than 20 g in each group, and with mean values trivially higher in indigenous newborns. The proportion weighing less than 2500 g at birth increased modestly from 5.2% to 5.6% in non-indigenous newborns whereas the indigenous births remained constant at 5.2%. In multiple regression analyses, adjusting flexibly for gestational age and maternal characteristics, the occurrence of an indigenous surname added only 14 g to an average infant's birthweight while holding other factors constant. Results for length at birth were similar, and adjusted time trend variation in both outcomes was trivially small after adjustment. Anthropometric indexes at birth in Chile are quite favorable by international standards. Conclusion There is only a trivial degree of ethnic disparity in these values, in contrast to conditions for ethnic minorities in other countries. Moreover, these values remained roughly constant over the 5 years of observation in this study. PMID:20598150

  1. Prediction of cold and heat patterns using anthropometric measures based on machine learning.

    Science.gov (United States)

    Lee, Bum Ju; Lee, Jae Chul; Nam, Jiho; Kim, Jong Yeol

    2018-01-01

    To examine the association of body shape with cold and heat patterns, to determine which anthropometric measure is the best indicator for discriminating between the two patterns, and to investigate whether using a combination of measures can improve the predictive power to diagnose these patterns. Based on a total of 4,859 subjects (3,000 women and 1,859 men), statistical analyses using binary logistic regression were performed to assess the significance of the difference and the predictive power of each anthropometric measure, and binary logistic regression and Naive Bayes with the variable selection technique were used to assess the improvement in the predictive power of the patterns using the combined measures. In women, the strongest indicators for determining the cold and heat patterns among anthropometric measures were body mass index (BMI) and rib circumference; in men, the best indicator was BMI. In experiments using a combination of measures, the values of the area under the receiver operating characteristic curve in women were 0.776 by Naive Bayes and 0.772 by logistic regression, and the values in men were 0.788 by Naive Bayes and 0.779 by logistic regression. Individuals with a higher BMI have a tendency toward a heat pattern in both women and men. The use of a combination of anthropometric measures can slightly improve the diagnostic accuracy. Our findings can provide fundamental information for the diagnosis of cold and heat patterns based on body shape for personalized medicine.

  2. Anthropometric and performance measures to study talent detection in youth volleyball.

    Science.gov (United States)

    Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Annino, Giuseppe; Padua, Elvira; Tancredi, Virginia

    2017-12-01

    The aim of this work was to study anthropometric and performance measurements in 60 young male volleyball players (YV) and 60 youth not active in the sport (YNA) to assess which of these would be more useful to study the characteristics of potential performers. Eight measures to assess anthropometric characteristics, six performance measures and two tests for joint mobility were used. Also relative age and level of maturation were assessed. The anthropometric variables, relative age and level of maturation measured did not show statistically significant differences between groups. The YV and YNA groups showed differences in the performance measures. YV group was characterized by a better performance of the ability to repeat short sprints, of the upper limbs, abdominal muscles and lower limbs, with a medium effect size (Shuttle Running Test: 0.6; Push-Up: 0.5; Sit-Up: 0.4; counter movement jump: 0.4). These performance variables were very sensitive and specific: the SRT measurement had the best positive likelihood ratio that indicates the utility of the test in identifying type of players (YV and YNA). In talent detection in youth volleyball, in the 11-13 age range, performance variables should be preferred to anthropometric ones.

  3. Errors in anthropometric measurements in neonates and infants

    Directory of Open Access Journals (Sweden)

    D Harrison

    2001-09-01

    Full Text Available The accuracy of methods used in Cape Town hospitals and clinics for the measurement of weight, length and age in neonates and infants became suspect during a survey of 12 local authority and 5 private sector clinics in 1994-1995 (Harrison et al. 1998. A descriptive prospective study to determine the accuracy of these methods in neonates at four maternity hospitals [ 2 public and 2 private] and infants at four child health clinics of the Cape Town City Council was carried out. The main outcome measures were an assessment of three currently used methods namely to measure crown-heel length with a measuring board, a mat and a tape measure; a comparison of weight differences when an infant is fully clothed, naked and in napkin only; and the differences in age estimated by calendar dates and by a specially designed electronic calculator. The results showed that the current methods which are used to measure infants in Cape Town vary widely from one institution to another. Many measurements are inaccurate and there is a real need for uniformity and accuracy. This can only be implemented by an effective education program so as to ensure that accurate measurements are used in monitoring the health of young children in Cape Town and elsewhere.

  4. Different anthropometric adiposity measures and their association with cardiovascular disease risk factors: a meta-analysis.

    Science.gov (United States)

    van Dijk, S B; Takken, T; Prinsen, E C; Wittink, H

    2012-05-01

    To investigate which anthropometric adiposity measure has the strongest association with cardiovascular disease (CVD) risk factors in Caucasian men and women without a history of CVD. Systematic review and meta-analysis. We searched databases for studies reporting correlations between anthropometric adiposity measures and CVD risk factors in Caucasian subjects without a history of CVD. Body mass index (BMI), waist circumference, waist-to-hip ratio, waist-to-height ratio and body fat percentage were considered the anthropometric adiposity measures. Primary CVD risk factors were: systolic blood pressure, diastolic blood pressure, high density lipoprotein (HDL) cholesterol, triglycerides and fasting glucose. Two independent reviewers performed abstract, full text and data selection. Twenty articles were included describing 21,618 males and 24,139 females. Waist circumference had the strongest correlation with all CVD risk factors for both men and women, except for HDL and LDL in men. When comparing BMI with waist circumference, the latter showed significantly better correlations to CVD risk factors, except for diastolic blood pressure in women and HDL and total cholesterol in men. We recommend the use of waist circumference in clinical and research studies above other anthropometric adiposity measures, especially compared with BMI, when evaluating CVD risk factors.

  5. Comparison of Some Biomotoric Properties and Anthropometric Measurements of Male Basketball and Football Players

    Science.gov (United States)

    Turna, Bülent; Kilinç, Fatih

    2018-01-01

    The purpose of this study is to determine and compare some biomotoric properties and anthropometric measurements of Antalya Muratpasa High School Boys' Basketball Team and Football Team. Thirty volunteering players from Antalya Muratpasa High School Boys' Basketball and Football Teams participated in the study. Fifteen of the participants were…

  6. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    Objective: The purpose of this study was to determine the accuracy and repeatability of linear anthropometric measurements on the soft tissue surface model generated from cone beam computed tomography scans. Materials and Methods: The study sample consisted of seven cadaver heads. The accuracy and

  7. Association of Anthropometric Measurement Methods with Cardiovascular Disease Risk in Turkey

    Directory of Open Access Journals (Sweden)

    Kaan Sözmen

    2016-03-01

    Full Text Available Objective: The aim of this study is to compare the predic­tive power of anthropometric indices for risk of developing Coronary Heart Disease (CHD or CHD death. Methods: We used cross-sectional data from nationally representative Chronic Diseases and Risk Factors Sur­vey conducted by the Ministry of Health in 2011. Body mass index (BMI, waist circumference (WC, waist-to-hip ratio (WHR, waist to height ratio (WHtR, body adiposity index (BAI and A Body Shape Index (ABSI formed the anthropometric measures. For each participant risk of de­veloping CHD or dying from CVDs were calculated based on Framingham and SCORE risk equations. Predictive ability of anthropometric measurements was assessed by receiver operating characteristic (ROC curves. Results: Anthropometric measurements of central obe­sity recorded higher area under the ROC curve (AUC values than BMI in both men and women. While ABSI had the highest AUC values for Framingham 10-year pre­dicted risk (FRS for CHD death (AUC = 0.613, SCORE 10-year risk for CVD death (AUC = 0.633, in women AUC for ABSI was the highest for only SCORE risk threshold (AUC = 0.705. Among women, WHtR was found to be the best indicator for estimating CHD incidence (AUC = 0.706 and death from CVD (AUC = 0.696. Conclusion: Compared to traditional anthropometric measurements such as BMI, ABSI was a better indicator for given thresholds for estimating the risk of developing CHD and CVD death in men. Among women WHtR made better predictions for FRS thresholds, however, ABSI was better for predicting 10-year risk of CVD death calculated by SCORE risk equation.

  8. Standard Weights and Measures

    Indian Academy of Sciences (India)

    The mass standard, represented by the proto- type kilogram, is the only remaining artifact, but there are promising proposals to replace that in the near future. Ever since humans started living in community settle- ments, day to day activities have required the adoption of a set of standards for weights and measures. For ex-.

  9. Prenatal exposures to perfluorinated chemicals and anthropometric measures in infancy

    DEFF Research Database (Denmark)

    Andersen, Camilla Schou; Fei, Chunyuan; Gamborg, Michael

    2010-01-01

    Perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) are persistent chemicals that may affect growth early in life. The authors estimated the associations between maternal plasma levels of PFOS and PFOA and infants' weight, length, and body mass index development during the first year....... Multiple linear regression models were used for analyses, and maternal PFOS and PFOA concentrations (ng/mL) were inversely related to children's weight in the first year of life: adjusted regression coefficients: -1.1 g (95% confidence interval (CI): -4.6, 2.3) at 5 months and -5.8 g (95% CI: -10.4, -1.......2) at 12 months for PFOS; -10.6 g (95% CI: -30.2, 8.9) at 5 months and -19.7 g (95% CI: -45.9, 6.5) at 12 months for PFOA. A similar pattern was observed for body mass index measurements, and no associations with length were found. After sex stratification, the inverse associations with weight and body...

  10. A new technique to determine vertical dimension of occlusion from anthropometric measurement of interpupillary distance.

    Science.gov (United States)

    Ladda, Ruchi; Kasat, Vikrant O; Bhandari, Aruna J

    2014-10-01

    A number of techniques are being practiced for the evaluation of VDO, but none of them is scientifically more accurate than other. Each method advocated has its own limitations. The purpose of this study was to find correlation between vertical dimension of occlusion (VDO) and interpupillary distance (IPD). A cross-sectional study was conducted on 400 dentate subjects comprising of 200 males and 200 females. Anthropometric measurement of VDO was recorded clinically using modified digital vernier caliper. Also, a standardized digital photograph of face was generated from the frontal aspect using a digital camera for the measurement of IPD in millimeters. Correlation between VDO and IPD was studied using Spearman's coefficient. For the execution of regression command and preparation of prediction equations to estimate VDO, Statistical Package for Social Sciences (SPSS) Software Version 11.5 was used. VDO and IPD was more in males compared to females. VDO was significantly and positively correlated with IPD only in males whereas females showed a weak correlation. Hence, regression equation was derived only for males. VDO estimation using regression equation for IPD had a standard error of ± 3.94 in males. Since the variations between VDO and IPD are within the range of 2-4 mm, VDO prediction through this method is reliable and reproducible for male patients. Also, the method is simple, economic, and non invasive; hence it could be recommended for everyday practice to determine vertical dimension of occlusion in case of male patients. Key words:Anthropometry, interpupillary distance, jaw relation, vertical dimension of occlusion.

  11. A school anthropometric record card: what should be measured and why measure it?

    Directory of Open Access Journals (Sweden)

    Carmem Cristina Beck

    2007-03-01

    Full Text Available The objective of this study is to propose a model for a School Anthropometric Record Card (SARD, based on the criteria and protocols used in anthropometry. This model aims to answer questions such as: what to measure and why measure, aiming to contribute to the implementation of a proposal that would be coherent with current tendencies, which aim at educating students to adopt a healthy lifestyle. In order to construct this model, note was taken of the Brazilian educational context, in order to offer alternatives for expansion and inclusion within a multidisciplinary perspective. The implementation in schools of a system for anthropometric assessment is of fundamental importance since it would allow for growth to be monitored and risk factors for the detection of the development of diseases, which have onset at ever younger ages. Therefore, topics were discussed relating to anthropometric measurements in a school environment and the proposal of a SARD model, in addition to the procedures for measurement, interpretation and recommendation. The SARD is aimed at Physical Education teachers and other health professionals, researchers and all educators with an interest in promoting a healthy lifestyle, with emphasis on features of growth and on risk factors for diseases, particularly those related to overweight and eating disorders. It is believed that the support of educational institutions is a determinant factor for the success of implementing a SARD as an integral part of schools’ educational policy projects. RESUMO O presente estudo tem como objetivo propor um modelo de Ficha Antropométrica Escolar (FAE, fundamentado nos critérios e protocolos utilizados pela antropometria. Este modelo buscou responder a questionamentos como: o que e para que medir, visando contribuir para a efetivação de uma proposta coerente com as tendências atuais, que visam à educação para a adoção de um estilo de vida saudável. Para a construção deste modelo

  12. Anthropometric body measurements based on multi-view stereo image reconstruction.

    Science.gov (United States)

    Li, Zhaoxin; Jia, Wenyan; Mao, Zhi-Hong; Li, Jie; Chen, Hsin-Chen; Zuo, Wangmeng; Wang, Kuanquan; Sun, Mingui

    2013-01-01

    Anthropometric measurements, such as the circumferences of the hip, arm, leg and waist, waist-to-hip ratio, and body mass index, are of high significance in obesity and fitness evaluation. In this paper, we present a home based imaging system capable of conducting anthropometric measurements. Body images are acquired at different angles using a home camera and a simple rotating disk. Advanced image processing algorithms are utilized for 3D body surface reconstruction. A coarse body shape model is first established from segmented body silhouettes. Then, this model is refined through an inter-image consistency maximization process based on an energy function. Our experimental results using both a mannequin surrogate and a real human body validate the feasibility of the proposed system.

  13. Anthropometric Body Measurements Based on Multi-View Stereo Image Reconstruction*

    Science.gov (United States)

    Li, Zhaoxin; Jia, Wenyan; Mao, Zhi-Hong; Li, Jie; Chen, Hsin-Chen; Zuo, Wangmeng; Wang, Kuanquan; Sun, Mingui

    2013-01-01

    Anthropometric measurements, such as the circumferences of the hip, arm, leg and waist, waist-to-hip ratio, and body mass index, are of high significance in obesity and fitness evaluation. In this paper, we present a home based imaging system capable of conducting automatic anthropometric measurements. Body images are acquired at different angles using a home camera and a simple rotating disk. Advanced image processing algorithms are utilized for 3D body surface reconstruction. A coarse body shape model is first established from segmented body silhouettes. Then, this model is refined through an inter-image consistency maximization process based on an energy function. Our experimental results using both a mannequin surrogate and a real human body validate the feasibility of proposed system. PMID:24109700

  14. A new technique to determine vertical dimension of occlusion from anthropometric measurement of interpupillary distance

    OpenAIRE

    Ladda, Ruchi; Kasat, Vikrant O.; Bhandari, Aruna J.

    2014-01-01

    Background: A number of techniques are being practiced for the evaluation of VDO, but none of them is scientifically more accurate than other. Each method advocated has its own limitations. Objectives: The purpose of this study was to find correlation between vertical dimension of occlusion (VDO) and interpupillary distance (IPD). Material and Methods: A cross-sectional study was conducted on 400 dentate subjects comprising of 200 males and 200 females. Anthropometric measurement of VDO was r...

  15. Monte Carlo simulation of an anthropometric phantom used for calibrating in vivo K-XRF spectroscopy measurements of stable lead in bone.

    Science.gov (United States)

    Lodwick, Camille J; Spitz, Henry B

    2008-12-01

    An anthropometric surrogate (phantom) of the human leg was defined in the constructs of the Monte Carlo N Particle (MCNP) code to predict the response when used in calibrating K x-ray fluorescence (K-XRF) spectrometry measurements of stable lead in bone. The predicted response compared favorably with measurements using the anthropometric phantom containing a tibia with increasing stable lead content. These benchmark measurements confirmed the validity of a modified MCNP code to accurately simulate K-XRF spectrometry measurements of stable lead in bone. A second, cylindrical leg phantom was simulated to determine whether the shape of the calibration phantom is a significant factor in evaluating K-XRF performance. Simulations of the cylindrical and anthropometric calibration phantoms suggest that a cylindrical calibration standard overestimates lead content of a human leg up to 4%. A two-way analysis of variance determined that phantom shape is a statistically significant factor in predicting the K-XRF response. These results suggest that an anthropometric phantom provides a more accurate calibration standard compared to the conventional cylindrical shape, and that a cylindrical shape introduces a 4% positive bias in measured lead values.

  16. [Anthropometric cranial measurements of normal newborn in Sergipe--Northeast of Brazil].

    Science.gov (United States)

    Oliveira, Hélio A; Paixão, Antonio C da; Paixão, Marcelo de Oliveira R; Barros, Vanessa Cristina Farias; Barros, Vanessa Cristina F

    2007-09-01

    The anthropometric measurement of the skull is essential for the evaluation of the newborn. The anthropometric measurements utilized at the present time are based in the results obtained for more than five decades, which are not able to determine a national pattern mostly likely due to some ethnic influences. We carried out an analytical descriptive study in a maternity hospital in Aracaju-Sergipe, Northeast of Brazil. Measurements of cephalic perimeter, biauricular and anteroposterior distances, cephalic index and fontanels were obtained from 450 newborns with gestational age from 37 and 42 weeks; 49.3% were male and 50.6% female. The cephalic perimeter ranged from 30.0 cm to 39.8 cm with mean value of 34.14+/-2.48 P50 34 cm, and cephalic index ranged from 0.69 and 1.13 with mean value of 0.98+/-0.06 P50 1. A comparison was made between brazilian and foreign studies; the results of the newborn from Sergipe were closer to results obtained in the southeast region than the ones obtained in the northeast region itself. The possibility of ethnical influences was raised as well as the need to design a multicentric study in order to define an anthropometric profile of the Brazilian newborn.

  17. Anthropometric Measures and Frailty Prediction in the Elderly: An Easy-to-Use Tool

    Directory of Open Access Journals (Sweden)

    Vera Elizabeth Closs

    2017-01-01

    Full Text Available Purpose. Anthropometry is a useful tool for assessing some risk factors for frailty. Thus, the aim of this study was to verify the discriminatory performance of anthropometric measures in identifying frailty in the elderly and to create an easy-to-use tool. Methods. Cross-sectional study: a subset from the Multidimensional Study of the Elderly in the Family Health Strategy (EMI-SUS evaluating 538 older adults. Individuals were classified using the Fried Phenotype criteria, and 26 anthropometric measures were obtained. The predictive ability of anthropometric measures in identifying frailty was identified through logistic regression and an artificial neural network. The accuracy of the final models was assessed with an ROC curve. Results. The final model comprised the following predictors: weight, waist circumference, bicipital skinfold, sagittal abdominal diameter, and age. The final neural network models presented a higher ROC curve of 0.78 (CI 95% 0.74–0.82 (P<0.001 than the logistic regression model, with an ROC curve of 0.71 (CI 95% 0.66–0.77 (P<0.001. Conclusion. The neural network model provides a reliable tool for identifying prefrailty/frailty in the elderly, with the advantage of being easy to apply in the primary health care. It may help to provide timely interventions to ameliorate the risk of adverse events.

  18. Nutritional assessment and its correlation with anthropometric measurements in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Behrooz Ebrahimzadeh Koor

    2015-01-01

    Full Text Available One of the most important problems in patients on hemodialysis (HD is chronic malnutrition. This study is aimed to assess the prevalence of malnutrition using a subjective global assessment (SGA in HD patients referred to the Valie ASR Hospital, Arak, Iran. In this descriptive analysis study, 190 HD patients were selected with random sampling. SGA and anthropometric and biochemical measurements were assessed in all patients. Data were analyzed with the Chi-square and t-tests and Pearson correlation coefficient. P 50% of patients on maintenance HD had mild or moderate malnutrition. There was no case of severe malnutrition. Duration of dialysis treatment and some anthropometric indices (weight, BMI and MAC also showed a significant correlation with SGA score, which are important to determine the nutritional status of HD patients.

  19. Standard Weights and Measures

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 8. Standard Weights and Measures. Vasant Natarajan. General Article Volume 6 Issue 8 August 2001 pp 44-59. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/006/08/0044-0059. Author Affiliations.

  20. Some metabolic and anthropometric variables in obes children by measuring serum insulin, and leptin

    International Nuclear Information System (INIS)

    Nour Eldin, A.M.

    2004-01-01

    The present study aimed to assess serum leptin level in obese children to study its correlation with some metabolic variables as serum insulin and serum glucose. The study was conducted on 30 obese children of age from 9-14 years with body mass index (BMI) > 27.8 Kg/m 2 . All children were subjected to history taking, clinical examination, anthropometric measurements and laboratory investigations including fasting serum leptin, insulin and blood glucose. Serum leptin was significantly higher in obese children (102.3± 56.2 ng/ml) compared to non-obese ones (48.15±26.1 ng/ml). The relation between serum leptin and anthropometric measurements and laboratory investigations including fasting serum insulin and blood glucose. Serum leptin was significantly higher in obese children (102.3± 56.2 ng/ml)compared to non-obese ones (48.15±26.1 ng/ml). The relation between serum leptin and anthropometric variables was positively correlated with BMI r s = 0.68, (p s = 0.59.(p<0.01). It is concluded that serum leptin is increased in obesity and its concentration effects the size of the body. Moreover, the relation of leptin and insulin suggests a positive role of leptin in insulin resistance, which are common metabolic disorders associated with obesity

  1. Associations Between Anthropometric Measurements and Cardiometabolic Risk Factors in White European and South Asian Adults in the United Kingdom.

    Science.gov (United States)

    Kidy, Farah F; Dhalwani, Nafeesa; Harrington, Deirdre M; Gray, Laura J; Bodicoat, Danielle H; Webb, David; Davies, Melanie J; Khunti, Kamlesh

    2017-06-01

    To investigate the association of 4 anthropometric measurements with cardiometabolic risk factors in a UK biethnic sample of South Asians (SAs) and white Europeans (WEs). Baseline data were collected from adults of WE and SA origin participating in the Leicester arm of the Anglo-Danish-Dutch Study of Intensive Treatment in People with Screen Detected Diabetes in Primary Care (ADDITION-Leicester) study between August 2004 and December 2007. Overall, 6268 WE and SA adults had measures of body mass index, waist circumference, waist-to-hip ratio, and waist-to-height ratio assessed between June 18, 2004, and December 4, 2007. Hypertension, dyslipidemia, and dysglycemia were established from venous blood samples using standard definitions. Crude and adjusted (covariates used were age, sex, ethnicity, smoking, and alcohol consumption) odds ratios were calculated using multivariate logistic regression. Receiver operating characteristic curves and the area under the curve were used to calculate optimal cut points for the whole cohort and for both ethnic groups. Increases in all anthropometric measurements resulted in a higher odds ratio for each of the risk factors in both the crude and adjusted models (P<.001). The adjusted odds ratios for dyslipidemia, hypertension, and dysglygemia ranged from 1.30 to 1.35, from 1.36 to 1.52, and from 1.62 to 1.75 (P<.001 for all), respectively, in WEs. The adjusted odds ratio for dyslipidemia, hypertension, and dysglygemia ranged from 1.50 to 1.65 (P<.01), from 1.40 to 1.60 (P<.01), and from 1.96 to 2.11 (P<.001 for all), respectively, in SAs. The areas under the receiver operating characteristic curves for all the anthropometric measurements had low accuracy (P<.70) for the whole cohort and when stratified by ethnicity and sex. There is insufficient evidence to recommend replacing body mass index with another anthropometric measurement for the ethnically diverse population in the United Kingdom. clinicaltrials.gov Identifier: NCT

  2. Evaluation of the match between anthropometric measures and school furniture dimensions in Chile.

    Science.gov (United States)

    Castellucci, H I; Catalán, M; Arezes, P M; Molenbroek, J F M

    2015-01-01

    Students are exposed to the first systematic tasks or activities that a human being carries out in his/her life while at school. In this workplace situation, school furniture is a key factor for the adoption of proper body posture. The aim of this paper was to observe and determine the potential mismatch between school furniture dimensions and anthropometric characteristics of the students from the Valparaíso region of Chile. The sample consisted of 3,078 volunteer participants from 18 schools (public, semi-public, private). Eight anthropometric measures were gathered, together with six furniture dimensions. Mismatch analyses were carried out by using pre-defined mismatch criteria. Many different types of school furniture were presented at the schools. Also, a high level of mismatch was registered for seat height, desk height and seat-to-desk clearance. Finally, the analysis of all considered dimensions together showed that there was a high level of cumulative mismatch. It can be concluded that there were high levels of mismatch between the school furniture and student anthropometric characteristics and that this mismatch varied within the difference types of schools. This situation may have occurred because furniture acquisition was made without considering any ergonomic criteria.

  3. Effect of Curcumin on Anthropometric Measures: A Systematic Review on Randomized Clinical Trials.

    Science.gov (United States)

    Hariri, Mitra; Haghighatdoost, Fahimeh

    2018-01-09

    Curcumin is an active constituent of turmeric. Recently, scientists have suggested that curcumin can be used in weight reduction. We performed a systematic review based on randomized controlled trials to assess the effects of curcumin supplementation on anthropometric variables. We searched databases including PubMed, Embase, Web of Science, Scopus, and Google Scholar up to August 2017. Randomized clinical trials assessing the effects of curcumin on anthropometric parameters in human adults were included. Eight randomized clinical trials were allowed to be included in the systematic review. Five articles used the regular form of curcumin with short follow-up duration and did not indicate any significant effect on anthropometric measures, while three articles with significant results used either the more bioavailable form of curcumin or a longer intervention duration. Randomized clinical trials related to curcumin effect on weight are limited but their result indicated useful effect of curcumin on weight. It seems that the bioavailable form of curcumin can reduce obesity and overweight. Further articles with longer duration of intervention and different forms of curcumin supplementation are necessary before any recommendation is made for clinical use of these interventions.

  4. Standardization of depression measurement

    DEFF Research Database (Denmark)

    Wahl, Inka; Löwe, Bernd; Bjørner, Jakob

    2014-01-01

    OBJECTIVES: To provide a standardized metric for the assessment of depression severity to enable comparability among results of established depression measures. STUDY DESIGN AND SETTING: A common metric for 11 depression questionnaires was developed applying item response theory (IRT) methods. Data...... of 33,844 adults were used for secondary analysis including routine assessments of 23,817 in- and outpatients with mental and/or medical conditions (46% with depressive disorders) and a general population sample of 10,027 randomly selected participants from three representative German household surveys....... RESULTS: A standardized metric for depression severity was defined by 143 items, and scores were normed to a general population mean of 50 (standard deviation = 10) for easy interpretability. It covers the entire range of depression severity assessed by established instruments. The metric allows...

  5. Comparative Study of Ultrasonographic and Anthropometric Measurements of Regional Adiposity in Metabolic Syndrome

    Science.gov (United States)

    Ibrahim, Jebin; Prasanthi, Krishna; Reddy, Harish T; Shah, Rushit Sandeep; Haritha, Ch

    2017-01-01

    Introduction Metabolic syndrome is complex disorder unifying dyslipidemia, insulin resistance and hyper insulinemia. Rising global epidemic of obesity has tremendous impact on metabolic syndrome. Ultrasound is becoming widely utilized modality for measuring the visceral adiposity. Aim To determine the usefulness of ultrasonographic measurements in the estimation of regional adiposity and to compare them with anthropometric measurements and to correlate ultrasonographic measurements of regional adiposity and metabolic syndrome. Materials and Methods A cross-sectional study was conducted to compare anthropometry and ultrasonography in assessing the regional adiposity in metabolic syndrome. A total of 105 consecutive participants were included in the study after scrutinizing them for various definable factors of metabolic syndrome. Body Mass Index (BMI) of all participants was calculated and their available serological investigations were gathered. Primarily participants were subjected for anthropometric measurements like waist circumference and hip circumference, further waist/hip ratio was calculated. Following which all participants underwent sonological examination and sonographic indices like intraabdominal fat thickness, preperitoneal fat thickness, minimum and maximum subcutaneous fat thicknesses were measured. Abdominal wall fat index was calculated as ratio of maximum preperitoneal fat thickness to minimum subcutaneous fat thickness. Statistical analysis was performed using SPSS (Statistical Package Social Science, version-10.0.5) software. A p-value was calculated and values <0.05 were considered as statistically significant. Results Significant correlation was established between the BMI and waist and hip circumferences. Mild positive correlation was obtained between BMI and sonographic indices like IAF, SCF and PPF with Pearson correlation (r) values of 0.324, 0.585 and 0.211 respectively. Anthropometric measurements showed higher r-values (WC- 0.624 and

  6. Association of diet and anthropometric measures as cardiovascular modifiable risk factors in young adults.

    Science.gov (United States)

    Mishra, Soumya; Banerjee, Swasti; Sengupta, Tridip Kumar; Behera, Anugya Aparajita; Manjareeka, Magna; Mishra, Jayanti

    2013-12-18

    Abstract Background: Cardiovascular accidents are the major cause of death in the developing world, accounting for nearly 40% of deaths in adult men and women. Developed countries have already brought this under control, whereas India has to take a giant leap. Diet plays a pivotal role among the various modifiable cardiovascular risk factors. The sole objective of this study is to point at nutrition as being the main modulator of different anthropometric parameters and directly or indirectly has a tremendous impact on the blood pressure levels even during young age. Methods: In a cross-sectional study involving 223 young adults, the pattern of food habits and level of physical activity were determined from self-reported questionnaires, while blood pressure, weight, height, waist circumference (WC), and hip circumference were measured, and body mass index (BMI) and waist-to-hip ratio (WHR) were computed. The subjects were grouped as normotensives and prehypertensives and also were compared according to their BMI and other parameters. Results: Statistically significant, greater association of weight followed by WC with the prehypertensive levels of blood pressure compared to other parameters was seen. The subjects detected as prehypertensives had predilection for salty, fried, oily, sweet, and fast food; BMI >25 kg/m2; and WC and WHR in high risk-categories per World Health Organization standards. More than 69% of subjects had high WHR, whereas only 9% of total subjects exercised regularly. Conclusions: Central obesity is associated with sedentary life and high intake of calories, leading to hypertension with advancing age. Early detection, awareness, and primary prevention would help reduce morbidity and mortality associated with cardiovascular diseases.

  7. A new technique to determine vertical dimension of occlusion from anthropometric measurements of fingers

    Directory of Open Access Journals (Sweden)

    Ruchi Ladda

    2013-01-01

    Full Text Available Purpose: The purpose of this study was to find the correlation between vertical dimension of occlusion (VDO and length of fingers. Materials and Methods: A cross-sectional study was conducted on 400 dentate subjects comprising of 200 males and 200 females. Anthropometric measurements of VDO, length of index finger, length of little finger, and distance from tip of thumb to tip of index finger of right hand were recorded clinically using modified digital vernier caliper. Correlation between VDO and length of fingers was studied using Spearman′s coefficient. For the execution of regression command and preparation of prediction equations to estimate VDO, Statistical Package for Social Sciences Software Version 11.5 was used. Results: VDO was significantly and positively correlated with all the parameters studied. In males, correlation of VDO was strongest for length of index finger (r-0.406 whereas in females, it was strongest for length of little finger (r-0.385. VDO estimation using regression equation had a standard error of ± 3.76 in males and ± 2.86 in females for length of index finger, ±3.81 and ± 2.74 in males and females respectively for length of little finger, ±3.99 and ± 2.89 in males and females respectively for distance from tip of thumb to tip of index finger. Conclusions: Since the variations between VDO and finger lengths are within the range of 2-4 mm, VDO prediction through this method is reliable, and reproducible. Also the method is simple, economic, and non-invasive; hence, it could be recommended for everyday practice.

  8. A new technique to determine vertical dimension of occlusion from anthropometric measurements of fingers.

    Science.gov (United States)

    Ladda, Ruchi; Bhandari, Aruna J; Kasat, Vikrant O; Angadi, Gangadhar S

    2013-01-01

    The purpose of this study was to find the correlation between vertical dimension of occlusion (VDO) and length of fingers. A cross-sectional study was conducted on 400 dentate subjects comprising of 200 males and 200 females. Anthropometric measurements of VDO, length of index finger, length of little finger, and distance from tip of thumb to tip of index finger of right hand were recorded clinically using modified digital vernier caliper. Correlation between VDO and length of fingers was studied using Spearman's coefficient. For the execution of regression command and preparation of prediction equations to estimate VDO, Statistical Package for Social Sciences Software Version 11.5 was used. VDO was significantly and positively correlated with all the parameters studied. In males, correlation of VDO was strongest for length of index finger (r-0.406) whereas in females, it was strongest for length of little finger (r-0.385). VDO estimation using regression equation had a standard error of ± 3.76 in males and ± 2.86 in females for length of index finger, ±3.81 and ± 2.74 in males and females respectively for length of little finger, ±3.99 and ± 2.89 in males and females respectively for distance from tip of thumb to tip of index finger. Since the variations between VDO and finger lengths are within the range of 2-4 mm, VDO prediction through this method is reliable, and reproducible. Also the method is simple, economic, and non-invasive; hence, it could be recommended for everyday practice.

  9. Effect of a trampoline exercise on the anthropometric measures and motor performance of adolescent students

    Directory of Open Access Journals (Sweden)

    Bahman Aalizadeh

    2016-01-01

    Full Text Available Background: Physical exercises can influence some anthropometric and fitness components differently. The aim of present study was to evaluate how a relatively long-term training program in 11-14-year-old male Iranian students affects their anthropometric and motor performance measures. Methods: Measurements were conducted on the anthropometric and fitness components of participants (n = 28 prior to and following the program. They trained 20 weeks, 1.5 h/session with 10 min rest, in 4 times trampoline training programs per week. Motor performance of all participants was assessed using standing long jump and vertical jump based on Eurofit Test Battery. Results: The analysis of variance (ANOVA repeated measurement test showed a statistically significant main effect of time in calf girth P = 0.001, fat% P = 0.01, vertical jump P = 0.001, and long jump P = 0.001. The ANOVA repeated measurement test revealed a statistically significant main effect of group in fat% P = 0.001. Post hoc paired t-tests indicated statistical significant differences in trampoline group between the two measurements about calf girth (t = −4.35, P = 0.001, fat% (t = 5.87, P = 0.001, vertical jump (t = −5.53, P = 0.001, and long jump (t = −10.00, P = 0.001. Conclusions: We can conclude that 20-week trampoline training with four physical activity sessions/week in 11-14-year-old students seems to have a significant effect on body fat% reduction and effective results in terms of anaerobic physical fitness. Therefore, it is suggested that different training model approach such as trampoline exercises can help students to promote the level of health and motor performance.

  10. [Nutritional status, anthropometrical measurements, socio-economic status, and physical activity in Brazilian university students].

    Science.gov (United States)

    Bion, F Martins; Chagas, M H de Castro; Muniz, G de Santana; de Sousa, L G Oliveira

    2008-01-01

    The physical activity and adequate food plays a key role in improving health and the control of diseases. This paper aims at determining the nutritional state through anthropometric measures, socioeconomic level, the most common illnesses and type of physical activity, beyond food consumption and the place where meals are taken, of under-graduate students of the Nutrition course in UFPE. The sample is constituted of 68 female students, of different periods and at ages between 18 and 27 years old. The process of selection of the sample was for convenience. The students voluntarily participated and answered three questionnaires, respectively, on their socioeconomic level (income of the family) and possible illnesses they had, measures of the cutaneous folds and type of practiced physical activity; register of consumed foods and local where the meals were carried. Statistical analysis was performed by absolute frequency, percentage, average and standard deviation. The margin of error used in the testing employees was 5%. In relation to the incomes, they had predominated above three minimum wages (86%), the parents have a predominant role in the expenditure of their study (46%), followed by the father (24%), mother (9%), husband (4%), other responsible ones (10%); 7% did not give information. The most common illnesses were: allergic rhinitis, tonsillitis, sleeplessness and intestinal constipation. The weight, the height, the index of body mass and the relation waist hip of the students were within normal standards. The abdominal circumference varied only in 2.57 cm between the studied age range. In relation to the practice of physical activities, 67% were sedentary, 20% practiced light activity and 13% moderate. In relation to where the meals are had, breakfast, in its majority (76%), was carried at home, followed by supper (56%), while lunch (41%) and snack 1 (34%), at University. Among the pupils who did not inform the place where they had their meals there was a

  11. Association between various anthropometric measures of obesity and markers of subclinical atherosclerosis.

    Science.gov (United States)

    Kommuri, Naga V A; Zalawadiya, Sandip K; Veeranna, Vikas; Kollepara, Sri Lakshmi S; Ramesh, Krithi; Briasoulis, Alexandros; Afonso, Luis

    2016-01-01

    Central obesity is a known cardiovascular risk factor and measures of visceral obesity are known to predict atherosclerosis. This study sought to explore the association between various anthropometric measures and markers of subclinical atherosclerosis (MoSCA) among low risk healthy individuals. Multi-Ethnic Study of Atherosclerosis (MESA) is a population-based study of Caucasian (38%), Afro-American (28%), Chinese (22%) and Hispanic (12%) subjects, aged 45-84 years, free from clinical cardiovascular disease. We performed a post hoc analysis of the limited access dataset of MESA subjects to evaluate the association between carotid intima media thickness and coronary artery calcium score (CACS), as MoSCA and various measures of obesity. Multivariable regression analyses adjusted for traditional cardiovascular risk factors, ethnicity and C-reactive protein were performed. Each unit increase in waist-hip ratio was strongly associated with increase in both common and internal carotid intima media thickness (beta: 0.12, 95% confidence interval (CI): 0.06 to 0.18, p central obesity were superior to body mass index as demonstrated by their consistent association with each category of CACS when compared to the reference category (CACS = 0). Compared to body mass index, measures of visceral obesity were significantly associated with MoSCA in this multiethnic healthy population. Waist-hip ratio seems to be more consistent in its association with various MoSCA compared to other anthropometric measures.

  12. Anthropometric measures in relation to Basal Cell Carcinoma: a longitudinal study

    Directory of Open Access Journals (Sweden)

    Pandeya Nirmala

    2006-03-01

    Full Text Available Abstract Background The relationship between anthropometric indices and risk of basal cell carcinoma (BCC is largely unknown. We aimed to examine the association between anthropometric measures and development of BCC and to demonstrate whether adherence to World Health Organisation guidelines for body mass index, waist circumference, and waist/hip ratio was associated with risk of BCC, independent of sun exposure. Methods Study participants were participants in a community-based skin cancer prevention trial in Nambour, a town in southeast Queensland (latitude 26°S. In 1992, height, weight, and waist and hip circumferences were measured for all 1621 participants and weight was remeasured at the end of the trial in 1996. Prevalence proportion ratios were calculated using a log-binomial model to estimate the risk of BCC prior to or prevalent in 1992, while Poisson regression with robust error variances was used to estimate the relative risk of BCC during the follow-up period. Results At baseline, 94 participants had a current BCC, and 202 had a history of BCC. During the 5-year follow-up period, 179 participants developed one or more new BCCs. We found no significant association between any of the anthropometric measures or indices and risk of BCC after controlling for potential confounding factors including sun exposure. There was a suggestion that short-term weight gain may increase the risk of developing BCC for women only. Conclusion Adherence to World Health Organisation guidelines for body mass index, waist circumference and waist/hip ratio is not significantly associated with occurrence of basal cell carcinomas of the skin.

  13. Anthropometric measures in relation to Basal Cell Carcinoma: a longitudinal study

    International Nuclear Information System (INIS)

    Olsen, Catherine M; Hughes, Maria Celia; Pandeya, Nirmala; Green, Adèle C

    2006-01-01

    The relationship between anthropometric indices and risk of basal cell carcinoma (BCC) is largely unknown. We aimed to examine the association between anthropometric measures and development of BCC and to demonstrate whether adherence to World Health Organisation guidelines for body mass index, waist circumference, and waist/hip ratio was associated with risk of BCC, independent of sun exposure. Study participants were participants in a community-based skin cancer prevention trial in Nambour, a town in southeast Queensland (latitude 26°S). In 1992, height, weight, and waist and hip circumferences were measured for all 1621 participants and weight was remeasured at the end of the trial in 1996. Prevalence proportion ratios were calculated using a log-binomial model to estimate the risk of BCC prior to or prevalent in 1992, while Poisson regression with robust error variances was used to estimate the relative risk of BCC during the follow-up period. At baseline, 94 participants had a current BCC, and 202 had a history of BCC. During the 5-year follow-up period, 179 participants developed one or more new BCCs. We found no significant association between any of the anthropometric measures or indices and risk of BCC after controlling for potential confounding factors including sun exposure. There was a suggestion that short-term weight gain may increase the risk of developing BCC for women only. Adherence to World Health Organisation guidelines for body mass index, waist circumference and waist/hip ratio is not significantly associated with occurrence of basal cell carcinomas of the skin

  14. Prenatal Triclosan Exposure and Anthropometric Measures Including Anogenital Distance in Danish Infants

    DEFF Research Database (Denmark)

    Lassen, Tina Harmer; Frederiksen, Hanne; Kyhl, Henriette Boye

    2016-01-01

    BACKGROUND: Triclosan (TCS) is widely used as an antibacterial agent in consumer products such as hand soap and toothpaste, and human exposure is widespread. TCS is suspected of having endocrine-disrupting properties, but few human studies have examined the developmental effects of prenatal TCS e......, Swan SH, Main KM, Andersson AM, Lind DV, Husby S, Wohlfahrt-Veje C, Skakkebæk NE, Jensen TK. 2016. Prenatal triclosan exposure and anthropometric measures including anogenital distance in Danish infants. Environ Health Perspect 124:1261-1268; http://dx.doi.org/10.1289/ehp.1409637....

  15. Reliability of anthropometric measurements in young male and female artistic gymnasts.

    Science.gov (United States)

    Siatras, Theophanis; Skaperda, Malamati; Mameletzi, Dimitra

    2010-12-01

    Body dimensions and body composition of children participating in artistic activities, such as gymnastics and many types of dancing, are important factors in performance improvement. The present study aimed to determine the reliability of a series of selected anthropometric measurements in young male and female gymnasts. Segment lengths, body breadths, circumferences, and skinfold thickness were measured in 20 young gymnasts by the same experienced examiner, using portable and easy-to-use instruments. All parameters were measured twice (test-retest) under the same conditions within a week's period. The high intra-class correlation coefficient (ICC) values ranging from 0.87 to 0.99, as well as the low coefficient of variation (CV) values (artistic gymnasts. Therefore, these measurements could contribute to further research in this field of investigation, helping to monitor young artistic gymnasts' growth status and identify specific characteristics for increased performance in this sport.

  16. Daily dietary energy and macronutrient intake and anthropometric measurements of the peritoneal dialysis patients.

    Science.gov (United States)

    Akbulut, Gamze; Sanlıer, Nevin; Inal, Salih; Tek, Nilüfer Acar; Oneç, Kürşad; Erten, Yasemin

    2013-01-01

    This study was planned to investigate the relation between dietary macronutrient status and anthropometric measurements in peritoneal dialysis (PD) patients. A total of 28 clinically stable patients were enrolled in this study. All patients were taken a dietary therapy according to the guidelines of the American Journal of Kidney Foundation for 12 weeks. The anthropometric measurements were taken by bioelectrical impedance analyzer. The daily macronutrient intakes of the patients were calculated by the food consumption records. The mean age was 48.3 ± 13.10 years [56.3 ± 7.41 years for males (n = 14) and 40.3 ± 12.84 years for females (n = 14)]. There were significant changes in fat percentage (%), total body water (TBW; %, L), extracellular water (ECW; %, L), basal metabolic rate over body weight (BMR/BW), and body fat mass index (BMFI) in males (p 0.05). The daily dietary energy and protein intakes were under the recommended level in the study period. Patients undergoing PD frequently have low intakes of protein and energy. It is recommended that individuals undergoing PD periodically maintain 3-day dietary records followed by dietary interviews conducted by a dietitian.

  17. Association between meal frequency with anthropometric measures and blood pressure in Iranian children and adolescents.

    Science.gov (United States)

    Ahadi, Zeinab; Kelishadi, Roya; Qorbani, Mostafa; Zahedi, Hoda; Motlagh, Mohammad E; Ardalan, Gelayol; Shafiee, Gita; Asayesh, Hamid; Larijani, Bagher; Heshmat, Ramin

    2016-07-08

    This study aimed to assess the association of meal frequency with anthropometric measures and blood pressure in Iranian children and adolescents. In this national survey, 14,880 students with 6-18 years of age were selected by stratified multistage sampling method from urban and rural regions of 30 provinces of Iran. Meal frequency was assessed by a questionnaire prepared based on global school-based student health survey .Physical measurements included height, weight, waist circumference, systolic blood pressure (SBP), and diastolic blood pressure (DBP). The participation rate was 90.6% including 49.24% girls and 75.5% urban residents. Skipping breakfast and dinner were more frequent in girls than in boys (71.6% vs. 64.1%, 91.2% vs. 86.9%, respectively, P0.05). Students who had very low intake and 1 meal per week had more risk of abdominal obesity compared with those who had 3 meals (OR 1.7, CI 95%: 1.3-2.3, and OR 1.6, CI 95%: 1.4-2.0, respectively). An inverse significant association between higher meal frequency and anthropometric indices was observed. Therefore, encouraging children and adolescents for regular meal intake should be considered as a health priority in the pediatric population.

  18. Comparative study of cranial anthropometric measurement by traditional calipers to computed tomography and three-dimensional photogrammetry.

    Science.gov (United States)

    Mendonca, Derick A; Naidoo, Sybill D; Skolnick, Gary; Skladman, Rachel; Woo, Albert S

    2013-07-01

    Craniofacial anthropometry by direct caliper measurements is a common method of quantifying the morphology of the cranial vault. New digital imaging modalities including computed tomography and three-dimensional photogrammetry are similarly being used to obtain craniofacial surface measurements. This study sought to compare the accuracy of anthropometric measurements obtained by calipers versus 2 methods of digital imaging.Standard anterior-posterior, biparietal, and cranial index measurements were directly obtained on 19 participants with an age range of 1 to 20 months. Computed tomographic scans and three-dimensional photographs were both obtained on each child within 2 weeks of the clinical examination. Two analysts measured the anterior-posterior and biparietal distances on the digital images. Measures of reliability and bias between the modalities were calculated and compared.Caliper measurements were found to underestimate the anterior-posterior and biparietal distances as compared with those of the computed tomography and the three-dimensional photogrammetry (P photogrammetry (P = 0.002). The coefficients of variation for repeated measures based on the computed tomography and the three-dimensional photogrammetry were 0.008 and 0.007, respectively.In conclusion, measurements based on digital modalities are generally reliable and interchangeable. Caliper measurements lead to underestimation of anterior-posterior and biparietal values compared with digital imaging.

  19. Prediction of insulin resistance with anthropometric measures: lessons from a large adolescent population

    Directory of Open Access Journals (Sweden)

    Wedin WK

    2012-07-01

    Full Text Available William K Wedin,1 Lizmer Diaz-Gimenez,1 Antonio J Convit1,21Department of Psychiatry, NYU School of Medicine, New York, NY, USA; 2Nathan Kline Institute, Orangeburg, NY, USAObjective: The aim of this study was to describe the minimum number of anthropometric measures that will optimally predict insulin resistance (IR and to characterize the utility of these measures among obese and nonobese adolescents.Research design and methods: Six anthropometric measures (selected from three categories: central adiposity, weight, and body composition were measured from 1298 adolescents attending two New York City public high schools. Body composition was determined by bioelectric impedance analysis (BIA. The homeostatic model assessment of IR (HOMA-IR, based on fasting glucose and insulin concentrations, was used to estimate IR. Stepwise linear regression analyses were performed to predict HOMA-IR based on the six selected measures, while controlling for age.Results: The stepwise regression retained both waist circumference (WC and percentage of body fat (BF%. Notably, BMI was not retained. WC was a stronger predictor of HOMA-IR than BMI was. A regression model using solely WC performed best among the obese II group, while a model using solely BF% performed best among the lean group. Receiver operator characteristic curves showed the WC and BF% model to be more sensitive in detecting IR than BMI, but with less specificity.Conclusion: WC combined with BF% was the best predictor of HOMA-IR. This finding can be attributed partly to the ability of BF% to model HOMA-IR among leaner participants and to the ability of WC to model HOMA-IR among participants who are more obese. BMI was comparatively weak in predicting IR, suggesting that assessments that are more comprehensive and include body composition analysis could increase detection of IR during adolescence, especially among those who are lean, yet insulin-resistant.Keywords: BMI, bioelectrical impedance

  20. Anthropometric measurements in patients with growth hormone deficiency before treatment with human growth hormone.

    Science.gov (United States)

    Zachmann, M; Fernandez, F; Tassinari, D; Thakker, R; Prader, A

    1980-05-01

    In 74 children (52 males, 22 females) with growth hormone (GH) deficiency (30 cases with isolated GH-deficiency, two of them familial; 4 familial and one isolated case with tendency for formation of antibodies against hGH; 29 with other pituitary hormone defects; 10 craniopharyngiomas), various anthropometric measurements were analyzed before treatment with hGH. In all groups, standing height, sitting height, and subischial leg height were equally retarded, and bihumeral width was more retarded than biiliac width; the head was relatively large; fat tissue was increased with subscapular skinfolds being greater than triceps skinfolds, indicating relative obestiy of the trunk; muscle and/or bone mass was reduced. In isolated GH-deficiency, head shape was slightly scaphoid; in combined defects, it was round, and in craniopharyngioma cases, it was brachycephalic. It is concluded that antrhopometric measurements may help in differentiating the type of GH-deficiency.

  1. The association between self-rated health and different anthropometric and body composition measures in the Chinese population

    Directory of Open Access Journals (Sweden)

    Kun Tang

    2017-04-01

    Full Text Available Abstract Background To analyze the strength of association between self-rated health and six anthropometric and body composition measures to explore the best indicator. Methods Analyses were based on the cross-sectional data from the China Kadoorie Biobank Study and approximately 300,000 adults were analyzed. Logistics regression was used to analyze the association between self-rated health (good or poor and anthropometric and body composition measures (height, weight, body mass index (BMI, waist circumference (WC, hip circumference (HC and body fat percentage, waist-to-hip ratio and waist-to-height ratio. Stratified analyses were undertaken to understand the effect modification of socioeconomic status on the association. Result Odds ratio of self-rated better health had an inverted U-shape association with weight, BMI, WC and body fat, with weight levels increasing until around 73.8 and 65.7 kg for male and female, BMI around 26.8 kg/m2, WC around 85.8 and 87.6 cm, body fat around 24.3 and 36.3%, and then declining thereafter. Height and HC also indicated a slightly inverted U-shape association. The strongest association was observed after adjustment was weight, with one standard deviation greater weight associated with 10.2% and 10.6% increased odds in male and female. Conclusions Being underweight and overweight are both risk factors for poor self-rated health in males and females, and weight is the best indicator of self-rated health compared with other measures.

  2. [Physical inactivity and anthropometric measures in school children from Paranavaí, Paraná, Brazil].

    Science.gov (United States)

    Guilherme, Flávio Ricardo; Molena-Fernandes, Carlos Alexandre; Guilherme, Vânia Renata; Fávero, Maria Teresa Martins; dos Reis, Eliane Josefa Barbosa; Rinaldi, Wilson

    2015-01-01

    To investigate the association between physical inactivity and anthropometric measurements in school children from Paranavaí-Paraná, Brazil. Cross-sectional survey, conducted in July and August 2013. Sample of 566 students (287 boys and 278 girls) from 6th to 9th grade aged 10 to 14 years of public and private schools from Paranavaí-PR, Southern Brazil. The variables analyzed were: time of weekly physical activity by a questionnaire (physical inactivity <300 minutes/week), body mass index (BMI) and waist circumference (WC). In the statistical analysis the U Mann-Whitney and Student t test were used for comparison between genders. To identify factors associated with insufficient levels of physical activity, univariate and multivariate logistic regression analysis was applied and expressed in Odds ratio (OR) and 95% confidence interval (CI). There was an association between physical inactivity and anthropometric measurements for BMI (p<0.001) and WC (p<0.001), with a prevalence rate of 56.1% and 52.7% of inactive adolescents, respectively. In the multivariate analysis, there was significant association of physical inactivity and overweight (OR 1.8, 95%CI: 1.1-3.0) and with increased waist circumference (OR 2.8, 95%CI: 1.4-3.8). Inadequate levels of physical activity is a determining factor for overweight and abdominal adiposity. Accordingly, preventive measures should be taken, especially in schools, emphasizing the importance of exercise in the control of body composition and reduction of weight. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  3. Relationship between anthropometric measures and sagittal spinal curvatures in adult male handball players

    Directory of Open Access Journals (Sweden)

    Ameer Mariam Abdul-Moneem

    2017-12-01

    Full Text Available Purpose. Increasing anthropometric measures bring considerable spinal loads during sports practice, which inversely affects the adaptation abilities of the spinal structures; this in turn influences the spinal curvatures. The study was conducted to explore the relationship between anthropometric measures and sagittal spinal curvatures in handball players. Method. The total of 83 male handball players were divided into 2 groups, depending on their body height: group 1 (age, 23.62 ± 2.07 years consisted of 40 handball players with height above average, group 2 (age, 24.63 ± 2.58 years consisted of 43 handball players with height below average. The thoracic and lumbar curvatures and trunk height were measured with the Formetric III 4D spine and posture analysis system. Results. The thoracic kyphosis of group 1 was significantly higher than that of group 2 (p = 0.038, without a significant difference in lumbar lordosis (p = 0.312, and significant difference in the coefficient of compensation between thoracic kyphosis and lumbar lordosis (p = 0.026. Group 1 showed strong positive correlation between body height and kyphotic angle (r = 0.897, and moderate positive correlation with lordosis angle (r = 0.496. In group 2, there was weak positive correlation with kyphotic angle (r = 0.381, and weak negative correlation with lumbar lordosis angle (r = -0.355. Conclusions. Increasing body height of handball players is associated with bigger kyphotic and lordotic angles. Owing to frequent sagittal asymmetric overloading of the spine during handball training, exercises that help maintain good posture and correct the thoracic kyphosis are required, especially for taller players.

  4. Comparative Study of Anthropometric Measurement and Body Composition between Elite Handball and Basketball Players

    Directory of Open Access Journals (Sweden)

    Aldijana Muratovic

    2014-09-01

    Full Text Available The purpose of this study was to describe anthropometric characteristics and body composition of elite handball and basketball players as well as to make comparisons between them. Fifty-nine males were enrolled in the study, divided into three groups: fifteen handball players, fourteen basketball players and thirty healthy sedentary subjects. The descriptive statistics were expressed as a mean (SD for each variable, while the ANOVA and LSD Post Hoc tests were carried out to detect the effects of each type of sport. The results showed there was no significant difference in body mass index among the groups, while a significant difference was found for body height and body weight as well as for all three of the body contents measured (muscle, bone and fat among the groups. These findings may give coaches from the region better working knowledge and suggest to them to follow recent selection process methods and to be more careful during the recruitment.

  5. Geographic clustering of elderly people with above-norm anthropometric measurements and blood chemistry

    Directory of Open Access Journals (Sweden)

    Carlos Mena

    2017-05-01

    Full Text Available The global percentage of people over 60 is strongly increasing and estimated to exceed 20% by 20,150, which means that there will be an increase in many pathological conditions related to aging. Mapping of the location of aging people and identification of their needs can be extremely valuable from a social-economic point of view. Participants in this study were 148 randomly selected adults from Talca City, Chile aged 60-74 at baseline. Geographic information systems (GIS analyses were performed using ArcGIS software through its module Spatial Autocorrelation. In this study, we demonstrated that elderly people show geographic clustering according to above-norm results of anthropometric measurements and blood chemistry. The spatial identifications found would facilitate exploring the impact of treatment programmes in communities where many aging people live, thereby improving their quality of life as well as reducing overall costs.

  6. Maternal anthropometric measurements as predictors of low birth weight in developing and developed countries.

    Science.gov (United States)

    Goto, Eita

    2015-10-01

    To evaluate the possibility of using maternal anthropometric measurements for prediction of low birth weight in developing and developed countries. Bivariate diagnostic meta-analysis was performed with hierarchical summary receiver operating characteristic curves. Ten databases, i.e., PubMed, EMBASE, CINAHL, PsycINFO, Wiley InterScience, ProQuest Health and Medical Complete™, ProQuest Dissertations and Theses Database, the entire Cochrane Library (e.g., CENTRAL), Google Scholar, and Scopus were searched. The references and PubMed-related citations of potentially eligible articles and reviews were also investigated. With regard to maternal height, weight, arm circumference, abdominal circumference, body mass index (BMI), and weight gain, 111, 126, 25, 4, 131, and 59 studies extracted from 49, 38, 12, 1, 50, and 23 data sources, respectively, were finally included in the analysis. The sensitivity [=0.46, 95 % confidence interval (CI) 0.35-0.52 to 0.64, 95 % CI 0.56-0.71], specificity (=0.46, 95 % CI 0.38-0.54 to 0.72, 95 % CI 0.64-0.79) and diagnostic odds ratios (=2, 95 % CI 1-2 to 3, 95 % CI 3-4) for maternal height, weight, arm circumferences, BMI, and weight gain were low and 95 % confidence and prediction regions were too large for practical use. The findings for abdominal circumference were not generalizable because only one data source was available. There is no evidence that maternal anthropometric measurements are good predictors of low birth weight.

  7. Evaluation of fetal anthropometric measures to predict the risk for shoulder dystocia.

    Science.gov (United States)

    Burkhardt, T; Schmidt, M; Kurmanavicius, J; Zimmermann, R; Schäffer, L

    2014-01-01

    To evaluate the quality of anthropometric measures to improve the prediction of shoulder dystocia by combining different sonographic biometric parameters. This was a retrospective cohort study of 12,794 vaginal deliveries with complete sonographic biometry data obtained within 7 days before delivery. Receiver-operating characteristics (ROC) curves of various combinations of the biometric parameters, namely, biparietal diameter (BPD), occipitofrontal diameter (OFD), head circumference, abdominal diameter (AD), abdominal circumference (AC) and femur length were analyzed. The influences of independent risk factors were calculated and their combination used in a predictive model. The incidence of shoulder dystocia was 1.14%. Different combinations of sonographic parameters showed comparable ROC curves without advantage for a particular combination. The difference between AD and BPD (AD - BPD) (area under the curve (AUC) = 0.704) revealed a significant increase in risk (odds ratio (OR) 7.6 (95% CI 4.2-13.9), sensitivity 8.2%, specificity 98.8%) at a suggested cut-off ≥ 2.6 cm. However, the positive predictive value (PPV) was low (7.5%). The AC as a single parameter (AUC = 0.732) with a cut-off ≥ 35 cm performed worse (OR 4.6 (95% CI 3.3-6.5), PPV 2.6%). BPD/OFD (a surrogate for fetal cranial shape) was not significantly different between those with and those without shoulder dystocia. The combination of estimated fetal weight, maternal diabetes, gender and AD - BPD provided a reasonable estimate of the individual risk. Sonographic fetal anthropometric measures appear not to be a useful tool to screen for the risk of shoulder dystocia due to a low PPV. However, AD - BPD appears to be a relevant risk factor. While risk stratification including different known risk factors may aid in counseling, shoulder dystocia cannot effectively be predicted. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  8. Coordinate Standard Measurement Development

    Energy Technology Data Exchange (ETDEWEB)

    Hanshaw, R.A.

    2000-02-18

    A Shelton Precision Interferometer Base, which is used for calibration of coordinate standards, was improved through hardware replacement, software geometry error correction, and reduction of vibration effects. Substantial increases in resolution and reliability, as well as reduction in sampling time, were achieved through hardware replacement; vibration effects were reduced substantially through modification of the machine component dampening and software routines; and the majority of the machine's geometry error was corrected through software geometry error correction. Because of these modifications, the uncertainty of coordinate standards calibrated on this device has been reduced dramatically.

  9. Combination with Anthropometric Measurements and MQSGA to Assess Nutritional Status in Chinese Hemodialysis Population

    Science.gov (United States)

    Chen, Jie; Peng, Hongquan; Yuan, Zhimin; Zhang, Kun; Xiao, Long; Huang, Jialian; Wang, Jingfeng; Huang, Hui

    2013-01-01

    Aims: To assess the nutritional status, combination with anthropometric measurements and modified quantitative subjective global assessment (MQSGA) was used in multi-center hemodialysis population in South China. Methods: A cross-sectional, descriptive-analytic study was performed in 4 teaching hospitals in South China, dated from January 2010 to December 2011. Nutritional status was assessed with MQSGA and related anthropometric indexes. Serum albumin and transthyretin were also determined for nutritional assessment. Results: Eighty-two randomly selected hemodialysis patients participated in the nutritional assessment, of which 75 hemodialysis patients completed all assessments. The average age was 62.70 ± 14.21 years. The mean duration of hemodialysis was 3.29 ± 1.08 years. Of the included patients, 32% patients were well nourished, 60% were mild to moderately malnourished, and 8% were severely malnourished. Along with the malnutrition severity, the serum transthyretin significantly decreased. However, no obvious changes were found in serum albumin. The mean value (Mean ± SD; 25.78 ± 4.09 cm) of mid arm circumference (MAC) was negatively correlated with MQSGA (r = -0.365; P = 0.002). Body mass index (BMI) (Mean ± SD; 21.6 ± 3.1 kg/m2) was also significantly negatively correlated with MQSGA (r = -0.392; P = 0.001). The areas under the receiver operating characteristic curve were 0.664 and 0.726, respectively. Conclusions: Malnutrition is very common in South China hemodialysis population. Both BMI and MAC were effective markers for assessing nutritional status. PMID:23801883

  10. Combination with anthropometric measurements and MQSGA to assess nutritional status in Chinese hemodialysis population.

    Science.gov (United States)

    Chen, Jie; Peng, Hongquan; Yuan, Zhimin; Zhang, Kun; Xiao, Long; Huang, Jialian; Wang, Jingfeng; Huang, Hui

    2013-01-01

    To assess the nutritional status, combination with anthropometric measurements and modified quantitative subjective global assessment (MQSGA) was used in multi-center hemodialysis population in South China. A cross-sectional, descriptive-analytic study was performed in 4 teaching hospitals in South China, dated from January 2010 to December 2011. Nutritional status was assessed with MQSGA and related anthropometric indexes. Serum albumin and transthyretin were also determined for nutritional assessment. Eighty-two randomly selected hemodialysis patients participated in the nutritional assessment, of which 75 hemodialysis patients completed all assessments. The average age was 62.70 ± 14.21 years. The mean duration of hemodialysis was 3.29 ± 1.08 years. Of the included patients, 32% patients were well nourished, 60% were mild to moderately malnourished, and 8% were severely malnourished. Along with the malnutrition severity, the serum transthyretin significantly decreased. However, no obvious changes were found in serum albumin. The mean value (Mean ± SD; 25.78 ± 4.09 cm) of mid arm circumference (MAC) was negatively correlated with MQSGA (r = -0.365; P = 0.002). Body mass index (BMI) (Mean ± SD; 21.6 ± 3.1 kg/m²) was also significantly negatively correlated with MQSGA (r = -0.392; P = 0.001). The areas under the receiver operating characteristic curve were 0.664 and 0.726, respectively. Malnutrition is very common in South China hemodialysis population. Both BMI and MAC were effective markers for assessing nutritional status.

  11. Optimal anthropometric measures and thresholds to identify undiagnosed type 2 diabetes in three major Asian ethnic groups.

    Science.gov (United States)

    Alperet, Derrick Johnston; Lim, Wei-Yen; Mok-Kwee Heng, Derrick; Ma, Stefan; van Dam, Rob M

    2016-10-01

    To identify optimal anthropometric measures and cutoffs to identify undiagnosed diabetes mellitus (UDM) in three major Asian ethnic groups (Chinese, Malays, and Asian-Indians). Cross-sectional data were analyzed from 14,815 ethnic Chinese, Malay, and Asian-Indian participants of the Singapore National Health Surveys, which included anthropometric measures and an oral glucose tolerance test. Receiver operating characteristic curve analyses were used with calculation of the area under the curve (AUC) to evaluate the performance of body mass index (BMI), waist circumference (WC), waist-to-hip ratio (WHR), and waist-to-height ratio (WHTR) for the identification of UDM. BMI performed significantly worse (AUCMEN  = 0.70; AUCWOMEN  = 0.75) than abdominal measures, whereas WHTR (AUCMEN  = 0.76; AUCWOMEN  = 0.79) was among the best performing measures in both sexes and all ethnic groups. Anthropometric measures performed better in Chinese than in Asian-Indian participants for the identification of UDM. A WHTR cutoff of 0.52 appeared optimal with a sensitivity of 76% in men and 73% in women and a specificity of 63% in men and 70% in women. Although ethnic differences were observed in the performance of anthropometric measures for the identification of UDM, abdominal adiposity measures generally performed better than BMI, and WHTR performed best in all Asian ethnic groups. © 2016 The Obesity Society.

  12. The influence of anthropometric factors on postural balance: the relationship between body composition and posturographic measurements in young adults

    Directory of Open Access Journals (Sweden)

    Angélica Castilho Alonso

    2012-12-01

    Full Text Available OBJECTIVE: The aim of the present study was to evaluate the influence of anthropometric characteristics and gender on postural balance in adults. One hundred individuals were examined (50 males, 50 females; age range 20-40 years. METHODS: The following body composition measurements were collected (using bone densitometry measurements: fat percentage (% fat, tissue (g, fat (g, lean mass (g, bone mineral content (g, and bone mineral density (g/cm2. In addition, the following anthropometric measurements were collected: body mass (kg, height (cm, length of the trunk-cephalic region (cm, length of the lower limbs (cm and length of the upper limbs (cm. The following indices were calculated: body mass index (kg/m², waist-hip ratio and the support base (cm². Also, a postural balance test was performed using posturography variables with open and closed eyes. RESULTS: The analysis revealed poor correlations between postural balance and the anthropometric variables. A multiple linear regression analysis demonstrated that the whole group (female and male height explained 12% of the medial-lateral displacement, 10% of the speed of oscillation, and 11% of the displacement area. The length of the trunk-cephalic length explained 6% of the displacement in the anteroposterior direction. With eyes closed, the support base and height explained 18% of the medial displacement, and the lateral height explained 10% of the displacement speed and 5% of the scroll area. CONCLUSION: Measured using posturography, the postural balance was only slightly influenced by the anthropometric variables, both with open and closed eyes. Height was the anthropometric variable that most influenced postural balance, both in the whole group and separately for each gender. Postural balance was more influenced by anthropometric factors in males than females.

  13. Beyond Body Mass Index: Using Anthropometric Measures and Body Composition Indicators to Assess Odds of an Endometriosis Diagnosis.

    Science.gov (United States)

    Backonja, Uba; Hediger, Mary L; Chen, Zhen; Lauver, Diane R; Sun, Liping; Peterson, C Matthew; Buck Louis, Germaine M

    2017-09-01

    Body mass index (BMI) and endometriosis have been inversely associated. To address gaps in this research, we examined associations among body composition, endometriosis, and physical activity. Women from 14 clinical sites in the Salt Lake City, Utah and San Francisco, California areas and scheduled for laparoscopy/laparotomy were recruited during 2007-2009. Participants (N = 473) underwent standardized anthropometric assessments to estimate body composition before surgery. Using a cross-sectional design, odds of an endometriosis diagnosis (adjusted odds ratio [aOR]; 95% confidence interval [CI]) were calculated for anthropometric and body composition measures (weight in kg; height in cm; mid upper arm, waist, hip, and chest circumferences in cm; subscapular, suprailiac, and triceps skinfold thicknesses in mm; arm muscle and fat areas in cm 2 ; centripetal fat, chest-to-waist, chest-to-hip, waist-to-hip, and waist-to-height ratios; arm fat index; and BMI in kg/m 2 ). Physical activity (metabolic equivalent of task-minutes/week) and sedentariness (average minutes sitting on a weekday) were assessed using the International Physical Activity Questionnaire-Short Form. Measures were modeled continuously and in quartiles based on sample estimates. Adjusted models were controlled for age (years, continuous), site (Utah/California), smoking history (never, former, or current smoker), and income (below, within 180%, and above of the poverty line). Findings were standardized by dividing variables by their respective standard deviations. We used adjusted models to examine whether odds of an endometriosis diagnosis were moderated by physical activity or sedentariness. Inverse relationships were observed between endometriosis and standardized: weight (aOR = 0.71, 95% CI 0.57-0.88); subscapular skinfold thickness (aOR = 0.79, 95% CI 0.65-0.98); waist and hip circumferences (aOR = 0.79, 95% CI 0.64-0.98 and aOR = 0.76, 95% CI 0.61-0.94, respectively); total

  14. Anthropometric measurements of adolescents from two Amazonian ecosystems: variations according to seasonality.

    Science.gov (United States)

    Silva, Hilton P; Veiga, Gloria V; Kac, Gilberto; Pereira, Rosangela A

    2010-03-01

    This paper aims to describe the nutritional status of Caboclo adolescents living in two areas of the Amazon Basin. Two cross-sectional studies, the first in the dry and the second in the wet season, were carried out in two Amazonian ecosystems: the forest and black water ecosystem, and the floodplain and white water ecosystem. Measurements of weight, stature, arm circumference and triceps, subscapular and suprailiac skinfolds were performed on 247 adolescents (10-19 years of age). Nutritional status was classified using body mass index according to international criteria and the prevalence of underweight and overweight was estimated. Linear mixed effects models were used with the anthropometric measurements as dependent variables and time interval, place of residence, sex, age and stature variation as independent variables. During the wet season, the prevalence of overweight among girls was higher in the forest (42%) than in the floodplain (9%). Longitudinal linear regression models showed that the arm circumference measurement was influenced both by seasonality and location, revealing that the increment between dry and wet seasons was less pronounced in the floodplain. At the time of the study, overweight already constituted a major public health concern among girls living in the forest area. In order to develop adequate public health policies for this important segment of the Amazon population further studies are necessary to investigate the role of environment and seasonality on the growth and nutritional status of adolescents.

  15. Obesity in Korean pre-adolescent school children: comparison of various anthropometric measurements based on bioelectrical impedance analysis.

    Science.gov (United States)

    Yoo, S; Lee, S-Y; Kim, K-N; Sung, E

    2006-07-01

    To examine the relationships between body mass index (BMI), percentage-weight-for-height (PWH) and percentage body fat (PBF), and to compare their validity based on PBF with the BMI criteria of International Obesity Task Force (IOTF) for childhood obesity in Korean pre-adolescent school children. Statistical comparative analysis for anthropometric measures. Korean pre-adolescent children (438 boys and 454 girls, aged 8-12 years, mean BMI 19.5+/-3.4 kg/m2). Body mass index and PWH were calculated as body size indices from height and weight. Hand-to-foot bioelectrical impedance analysis (BIA) was performed to obtain PBF values, with obese children defined as PBF above 35%. Sensitivity and specificity were displayed with the gold standard of PBF, and receiver operating characteristic (ROC) curves were used to assess the performance of BMI and PWH in detecting obesity. The prevalence of obesity varied by the criteria: 18.8% by Korean BMI standards for 95 percentile, 11% by the IOTF-BMI 30 kg/m2 and 29.4% by Korean PWH cutoffs. Body mass index and PWH were significantly correlated with PBF after adjusting for age, 0.910 (Pobesity among Korean pre-adolescent children widely varied according to the diagnostic criteria applied. Universally recommended cutoffs for children by IOTF showed the lowest sensitivity among the criteria used, and may therefore underestimate obesity in this population.

  16. Standard Weights and Measures

    Indian Academy of Sciences (India)

    and measures from olden days to their modern .... 1 second per day. John Harrison, a carpenter and self-taught clock-maker, refined temperature compensation techniques and added new methods of reducing friction ... slave pendulum gave the master pendulum gentle pushes needed to maintain its motion, and also drove.

  17. Effects of gamma oryzanol supplementation on anthropometric measurements & muscular strength in healthy males following chronic resistance training

    Directory of Open Access Journals (Sweden)

    Saghar Eslami

    2014-01-01

    Full Text Available Background & objectives: Enhanced muscle strength is seen when resistance exercise is combined with the consumption of nutritional supplements. Although there is a limited number of studies available about the efficacy of gamma oryzanol supplementation with resistance exercise in humans, but its usage as a nutritional supplement for strength is common in athletes. The aim of this study was to determine the effects of gamma oryzanol supplementation during 9-week resistance training on muscular strength and anthropometric measurements of young healthy males. Methods: In this double-blind clinical trial, changes of anthropometric measurements and muscular strength were studied after chronic resistance exercise and gamma oryzanol supplementation in 30 healthy volunteers (16 in supplement and 14 in placebo. Each day, gamma oryzanol supplement (600 mg and placebo (the same amount of lactose were consumed after training. The participants exercised with 80 per cent 1-Repetition Maximum (1-RM, for one hour and four days/week. Anthropometric measurements and subjects′ 1-RM for muscular strength were determined at the commencement and end of the 9-week study. Results: There was no significant difference between the baseline characteristics and target variables at baseline between the two groups. After gamma oryzanol supplementation, there was no significant difference in the means of anthropometric and skin fold measurements between the supplement and placebo groups. However, there were significant differences between the supplement and placebo groups for 1-RM of bench press and leg curl, which showed that gamma oryzanol improved muscle strength following resistance training. Interpretation & conclusions: Our findings indicated that 600 mg/day gamma oryzanol supplementation during the 9-week resistance training did not change anthropometric and body measurements, but it increased muscular strength in young healthy males. Further, studies need to be done

  18. Anthropometric measurements, dietary intake and physical activity level in medicine students from Santa Fe (Argentina

    Directory of Open Access Journals (Sweden)

    Cecilia Monsted

    2014-04-01

    Full Text Available Introduction: obesity and cardiovascular disease (CVD are increasing in the world and in Argentina too. Lifestyles, especially diet and physical activity (PA, are presented as key in preventing these diseases. The aim of the study was to assess anthropometric measurements, dietary intake and physical activity level in medical students, and evaluate the possible association between these variables.Material and methods: a cross-sectional study was performed in 141 students from the last three years of the career (21-31 years old. Body Mass Index (BMI, % Body Fat (%BF and Waist Circumference (WC were assessed and subjects were classified according to their cardiovascular risk (CVR from the WC. Dietary intake was assessed by a 24-hours register, a food frequency questionnaire and the pattern of consumption was compared with the Food Guide for Argentinean population. “Argenfoods” Table of Food Composition was used for nutritional assessment and compared with WHO goals for the Prevention of Non-communicable Chronic Diseases. Diet was evaluated by the International Dietary Quality Index (DQI-I and the compliance of the WHO goals for the Prevention of Non-communicable Chronic Diseases. Exercise was assessed by International Physical Activity Questionnaire (IPAQ. The possible association between different anthropometric variables, anthropometry and intake, and anthropometry and physical activity was assessed.Results: 3.5% of the students were obese (31.7 ± 0.7 kg/m2 and 25.5% were overweight (26.8 ± 1.6 kg/m2, 27.7% showed increased BF (women: 36.8 ± 3.4 %; men: 29.1 ± 3.4 % and 14.9% had limit BF (women: 31.7 ± 0,7%, men: 23.6 ± 3.4%, 23.4% had CVR per WC (women: 85.8 ± 5.6 cm; men: 101.4 ± 2.3 cm. 27.8% of normal weight individuals (women showed increased and limit BF (35.0 ± 0.9 %. CVR by WC was associated to BMI in both sexes (p=0.001, OR=6.24 and with BF (p=0.003, OR=4.57 in women. Dietary quality was good only in a 5% and poor in a 49

  19. Impact of anthropometric measures and serum leptin on severity of gastroesophageal reflux disease.

    Science.gov (United States)

    Abdelkader, N A; Montasser, I F; Bioumy, E E; Saad, W E

    2015-10-01

    The aim of this prospective study was to evaluate the impact of obesity, determined by different anthropometric measures, on clinical and endoscopic severity of GERD and the relation between serum leptin and clinical and endoscopic severity of GERD in Egyptian patients. The study was carried out at Ain Shams University Hospitals and Theodor Bilharz Research Institute, Cairo, Egypt. A total of 60 patients with clinically and endoscopically evident gastroesophageal reflux disease (GERD) were enrolled in this study as well as 20 healthy subjects matched for age and gender serving as the control group. Patients were divided according to their body mass index (BMI) into two groups: group 1 (n = 30): overweight and obese (BMI ≥ 25 and/or waist-to-height ratio [WHtR] ≥ 0.5) and group 2 (n = 30): normal weight (BMI ≥ 18 to GERD. Increased leptin hormone level is associated with clinical and endoscopic severity of GERD. Future trial on larger number of patients is emphasized. © 2014 International Society for Diseases of the Esophagus.

  20. Blood pressure in relation to selected anthropometric measurements in senior citizens.

    Science.gov (United States)

    Moni, M A; Rahman, M A; Haque, M A; Islam, M S; Ahmed, K

    2010-04-01

    This cross-sectional study was done to assess the blood pressure of the senior citizens in relation to the anthropometric measurements and indices. It was conducted among the Bangladeshi elderly citizens of selected areas of Dhaka city. Samples were selected by convenient technique. A pre-tested questionnaire and a check list were used for data collection. Data analysis was done by SPSS for Windows. Three areas of Dhaka city namely Nakhal Para, Badda and Mirpur were selected in this study. The study was conducted during January to June 2006. A total of 317 samples were studied. Mean age of the respondents was 67.1 years (+/-6.6 SD). Mean SBP and DBP measured were 126 mm of Hg (+/-20 SD) and 72 mm of Hg (+/-12 SD), respectively. Among them, 33.1% were hypertensive on BP measurement; amongst which 32.4% had both SBP and DBP raised; 55.2% had isolated systolic hypertension and 12.4% had DBP raised. Of them 44.8% were identified finally as hypertensive considering BP measurement and those taking antihypertensive medication. The majority were well nourished and at less health risk in terms of BMI, WC and WHR. There was a tendency of being hypertensive with overweight/obese (p<0.05), high WC (male p<0.05 and female p<0.01) and high WHR (female p<0.001). Percentage of hypertensive was higher among the seniors of the study areas especially among those who were overweight/obese or at health risk by WC/WHR.

  1. The Impact of Physical Activity and Dietary Measures on the Biochemical and Anthropometric Parameters in Obese Children. Is There Any Genetic Predisposition?

    Science.gov (United States)

    Zlatohlávek, Lukáš; Hubáček, Jaroslav Alois; Vrablík, Michal; Pejšová, Hana; Lánská, Věra; Češka, Richard

    2015-11-01

    The aim of the study was to monitor the importance of laboratory, anthropometric and genetic determination of the presence of risk factors for atherosclerosis, obesity, dyslipidemia and components of the metabolic syndrome in obese children and the response to dietary and regimen interventions in obese children. As a part of the study, 353 paediatric patients (46% boys, 54% girls) with obesity and dyslipidemia, aged 8-16 years, participated in a one-month lifestyle intervention programme. The programme involved a reduction of energy intake and supervised exercise programme consisting of 5 exercise units per day, each 50 minutes long. Standard biochemical methods were applied, including Lp-PLA2, as were anthropometric measurements and genetic analyses. During the reduction programme for the children there was a statistically significant decrease in all anthropometric indicators of bodyweight (pgenetic predisposition for obesity, as well as individuals with a better response to regimen interventions which could, among other things, be determined by the FTO and MC4R genotypes. Copyright© by the National Institute of Public Health, Prague 2015.

  2. A new anthropometric phantom of the human leg for calibrating in vivo measurements of stable lead in bone using x-ray fluorescence

    International Nuclear Information System (INIS)

    Spitz, Henry; Jenkins, Mark; Lodwick, Jeffrey

    1997-01-01

    Full text. A new anthropometric phantom of the human leg has been developed for calibrating in vivo measurements of stable lead in the bone using x-ray fluorescence. The phantom reproduces the shape and radiological characteristics of the midshaft of the human leg and includes tissue substitutes for cortical bone, bone marrow, and muscle which have been formulated using polyurethanes and calcium carbonate to provide the desired characteristics of density x-ray attenuation, and calcium content. The phantom includes a set of simulated tibia bones, each containing a precisely known concentration of stable lead, that can be easily inserted into the leg. Formerly, of a set of plexiglas cylinders filled with plaster of-paris, each containing a known lead content, was the consensus standard calibration phantom. Tissue substitute materials used in the new anthropometric calibration phantom are much more uniform in density and composition than the plaster-of-paris phantoms and its realistic appearance provides a practical means of evaluating the variability in measurements results due to the changes in subject-detector positioning. Use of the new anthropometric calibration phantom results in a energy spectrum that closely resembles the spectrum observed when measuring a human subject. The energy spectrum produced by the plaster-of-paris phantom lacks the substantial Compton Scattering component produced by the leg muscle mass which leads to unrealistic estimates of in vivo measurement sensitivity. The minimum detection limit (MDL) for in vivo measurement of stable lead in bone, using an efficiency derived from the new anthropometric phantom, ranges from 18,6 parts per million (ppm) to 26,3 ppm using the K β1,3 /Elastic ratio or the K 1 /Elastic ratio, respectively. These values are significantly greater than the MDL cited in the literature obtained using a efficiency derived the conventional cylindrical plaster-of-paris phantom. Likewise, the realistic shape of the new

  3. Risk factors for postmenopausal osteoporosis: anthropometric measurements, age, age at menopause and the time elapsed after menopause onset.

    Science.gov (United States)

    Akdeniz, Nurten; Akpolat, Veysi; Kale, Ahmet; Erdemoglu, Mahmut; Kuyumcuoglu, Umur; Celik, Yusuf

    2009-02-01

    The aim of this study was to determine, how much the anthropometric measurements and age affect the femur and vertebra T-scores by using correlation and regression analysis in postmenopausal women. Data of 540 healthy postmenopausal women were included in this analysis. Bone mineral density was determined by dual energy X-ray absorptiometry (DXA). The data of the patients related to height, weight, age, age at menopause were obtained from records, and body mass index (BMI) was calculated (BMI = W (kg)/H(m(2))). Statistical analyses were performed with SPSS 15.0 for Windows (SPSS, Chicago, IL). Mean age and standard deviation of 540 postmenopausal women was 59.3 +/- 8.4 years. The correlation coefficients among femur, vertebra T-scores, weight, the time elapsed after the menopause onset, age, BMI and height were found as follows, from higher to lower values with 0.465, 0.453, 0.411, 0.382, 0.232, respectively, and were statistically significant (p osteoporosis from higher to lower influence as follows: weight, menopause age, age, BMI and height. Weight and menopause age of the patients were the major determinants for osteoporosis.

  4. [Comparison of self-reported anthropometric variables and real measurement data].

    Science.gov (United States)

    Díaz-García, J; González-Zapata, L I; Estrada-Restrepo, A

    2012-06-01

    The objectives of this study were to evaluate self-reporting of weight, height, and waist circumference, and to compare that perception with the real measurements in college students of the MESPYN cohort--Medellin, Salud Pública y Nutrición--from the University of Antioquia (UdeA), Colombia. A cross-sectional study was conducted starting with the first measurement of the MESPYN Cohort 2009-2010. The sample included volunteer students from different academic areas. Self-perception of weight, height, and waist circumference were recorded before the real measurements were performed. Intraclass correlation coefficients (ICC) were calculated for all the variables, and an alpha of 0.05 was used. The concordance between real measurements and self-referred values was evaluated with the Bland and Altman method. 424 volunteer students were included. The average real weight (kg) in males was 67.4 +/- 10.4 and self-reported: 67.0 +/- 11.0; in females the real value was 55.7 +/- 10.1 and self-reported: 55.0 +/- 9.0. The average real height (m) in males was 1.73 +/- 6.1 and self-reported: 1.73 +/- 6.0; in females the real value was 1.60 +/- 5.9 and self-reported: 1.61 +/- 6.0. In males, the average real waist circumference (cm) was 76.6 +/- 8.0 and self-reported: 75.0 +/- 14.0; in females the real value was 69.9 +/- 8.0 and self-reported: 70.0 +/- 9.0. Weight ICC: 0.956, 95% CI (0.95; 0.97), (p < 0.01); height ICC: 0.953, 95%IC (0.91; 0.97), (p < 0.01), and waist circumference ICC: 0.593, 95% IC (0.55; 0.65), (p < 0.01). In conclusion, anthropometric nutritional evaluation of UdeA students can be performed with self-reported data for weight and height, but the evaluation of abdominal obesity requires direct measurement of waist circumference.

  5. Predicting gestational diabetes mellitus during the first trimester using anthropometric measurements and HOMA-IR.

    Science.gov (United States)

    Alptekin, Hüsnü; Çizmecioğlu, Ahmet; Işık, Hatice; Cengiz, Türkan; Yildiz, Murat; Iyisoy, Mehmet Sinan

    2016-05-01

    To determine the predictability of gestational diabetes mellitus (GDM) during the first trimester using the degree of insulin resistance and anthropometric measurements and to assign the risk of developing GDM by weight gained during pregnancy (WGDP). A total of 250 singleton pregnancies at 7-12 gestational weeks were studied. Body mass index (BMI), waist/hip ratio (WHR), quantitative insulin sensitivity check index (QUICKI), homeostasis model assessment-insulin resistance (HOMA-IR) scores and WGDP were determined. The backward stepwise method was applied to estimate possible associations with GDM. Cutoff points were estimated using receiver operating characteristic curve analysis. GDM was found in 20 of 227 singleton pregnancies (8.8 %). The calculated HOMA-IR, QUICKI, BMI, WHR, WGDP, and parity were significantly associated with GDM. Logistic regression analyses showed that three covariates (HOMA-IR, BMI, WGDP) remained independently associated with GDM. It was calculated as OR 1.254 (95 % CI 1.006-1.563), AUC 0.809, sensitivity 90 %, specificity 61 % with cutoff = 2.08 for HOMA-IR; OR 1.157 (CI 1.045-1.281), AUC 0.723, sensitivity 80 %, specificity 58 % with cutoff = 25.95 for BMI; OR 1.221, (CI 1.085-1.374), AUC 0.654, sensitivity 80 %, specificity 46 % with cutoff = 4.7 for WGDP. Despite a HOMA-IR score of >3.1 in pregnant women, GDM was detected in only three of 29 patients (10.3 %) if WGDP was HOMA-IR. In particular, if BMI is >25.95 kg/m(2) and the HOMA-IR score >2.08, controlling weight gain may protect against GDM.

  6. The Assessment of Anthropometric Measurements of the Students Attending Fatih Sultan Mehmet Primary School

    Directory of Open Access Journals (Sweden)

    Ruhusen Kutlu

    2008-06-01

    Full Text Available BACKGROUND: We aimed to evaluate the anthropometric measurements and nutrition and physical activity habits of the students attending Fatih Sultan Mehmet Primary School in the district of Meram, Konya. METHODS: This cross-sectional study was carried out among 368 children attending Fatih Sultan Mehmet Primary School. RESULTS: The students were in 11-14 age groups and were attending to 5th-8th grades. The students were classified according to height, weight and waist circumference (WC based on an age and sex-specific percentile curves. Of all 368 students, 174 (47.3% were male, 194 (52.7% female, the number of sibling was 2. There was no milk consumption habit among 222 students (60.3%. 52.7% (n=210 reported that they had made sportive activity 2-7 hours a week. The frequency of watching TV was 2 hours and under daily among 210 students (57.1%. Among the girls, the highest rate of the overweight was found as 7.7% and the highest rate of the obesity was found as 1.9% among 14 years olds. We found that waist circumference (WC increased with age both in boys and girls. The increase of the WC was greater in boys than the girls in 11 age group (p=0.020. BMI was statistically greater in girls than boys in 13 and 14 age groups (p=0.009, p=0.027, respectively. Malnutrition was found at the highest level as 17.1% in boys at the age of 13 and as 17.9% in girls at the age of 13. CONCLUSION: In this study, the frequency of malnutrition was found higher than obesity. It was necessary that nutrition and the regulations of the habits should be taken into account during the school health programs. [TAF Prev Med Bull 2008; 7(3.000: 205-212

  7. Influence of Anthropometric Measurements on Abnormal Gonadotropin Secretion in Women with Polycystic Ovary Syndrome

    International Nuclear Information System (INIS)

    Haider, S.; Mannan, N.; Qureshi, M. A.; Khan, A.

    2014-01-01

    Objective: To evaluate the influence of anthropometric measurements on abnormal gonadotropin secretion in patients with polycystic ovary syndrome (PCOS). Study Design: Cross-sectional study. Place and Duration of Study: The Institute of Basic Medical Sciences (IBMS), DUHS in collaboration with Gynae/infertility clinics of the Civil Hospital and Lady Dufferin Hospital, Karachi, from October 2010 to February 2011. Methodology: One hundred and sixty three oligomenorrhic PCOS women of reproductive age (18 - 40 years) fulfilling the revised Rotterdam 2003 criteria were studied. The data recorded on a prescribed proforma included current age, age at menarche, menstrual irregularities, presence of hirsuitism, acne, infertility, familial nature, blood pressure, BMI and waisthip ratio. Blood samples for gonadotropin assay were taken randomly on day 6th to 30th of menstrual cycle, in a gel tube. Hormonal assay was performed using chemiluminescent immunoassay. Kruskul Wallis test was used to assess the influence of BMI levels on LH:FSH values. Results: The mean weight was 66.14 +- 11.02 kg and mean BMI was 27.03 +- 4.42 kg/m2. There was no significant difference in mean LH/FSH ratio (p=.575) among BMI groups. However, there was a positive correlation between BMI and LH:FSH ratio (p=0.04, r=0.155). Conclusion: There was high frequency of obesity (69%) in women with PCOS. Although no significant difference was found between mean LH:FSH ratio among different BMI groups levels but significant correlation between BMI levels and LH: FSH suggested that there was positive relation between BMI and LH: FSH. (author)

  8. Comparative Study on the Effect of Plantago psyllium and Ocimum basilicum Seeds on Anthropometric Measures in Nonalcoholic Fatty Liver Patients

    OpenAIRE

    Akbarian, Shahab-Aldin; Asgary, Sedigheh; Feizi, Awat; Iraj, Bijan; Askari, Gholamreza

    2016-01-01

    Background: Due to the attribution of fatty liver with some chronic diseases such as obesity, finding a way to control obesity can be useful for the management of fatty liver. This study was performed to assess the effects of Plantago psyllium (PP) and Ocimum basilicum (OB) on anthropometric measurements in people with hepatic steatosis. Methods: All patients with nonalcoholic fatty liver disease (NAFLD) were enrolled in this four-arm parallel, randomized, and single blind trial. They ran...

  9. Comparative Study on the Effect of Plantago psyllium and Ocimum basilicum Seeds on Anthropometric Measures in Nonalcoholic Fatty Liver Patients.

    Science.gov (United States)

    Akbarian, Shahab-Aldin; Asgary, Sedigheh; Feizi, Awat; Iraj, Bijan; Askari, Gholamreza

    2016-01-01

    Due to the attribution of fatty liver with some chronic diseases such as obesity, finding a way to control obesity can be useful for the management of fatty liver. This study was performed to assess the effects of Plantago psyllium (PP) and Ocimum basilicum (OB) on anthropometric measurements in people with hepatic steatosis. All patients with nonalcoholic fatty liver disease (NAFLD) were enrolled in this four-arm parallel, randomized, and single blind trial. They randomly assigned into four groups receiving (1) OB 10 g/day; (2) PP 10 g/day; (3) mix of OB and PP 10 g/day; and (4) control group without placebo for 12 weeks. Anthropometric measurements were assessed during study baseline and after 12 weeks intervention. The data were analyzed using paired sample t -test for within group and analysis of covariance for between groups. In within group analysis, weight and body mass index show a significant reduction after 12 weeks intervention. In addition, soft lean mass and lean body mass were decreased in PP and mixed of PP and OB groups significantly; another group (OB) shows the same result for mass body fat. Although in intervention groups, we see considerable reduction, between group changes did not demonstrate the same consequences. The results of this study showed that administration of OB, PP, or mix of them for 12 weeks does not affect any of the anthropometric measures in NAFLD.

  10. Anthropometric measures and cognition in middle-aged HIV-infected and uninfected women. The Women's Interagency HIV Study

    Science.gov (United States)

    Gustafson, Deborah R.; Mielke, Michelle M.; Tien, Phyllis C.; Valcour, Victor; Cohen, Mardge; Anastos, Kathryn; Liu, Chenglong; Pearce, Leigh; Golub, Elizabeth T.; Minkoff, Howard; Crystal, Howard A.

    2014-01-01

    Objective To explore the relationship of body mass index (BMI), waist circumference (WC), and waist-to-hip ratio (WHR) with cognition in women with (HIV+) and without HIV (HIV-) infection. Design/Methods 1690 participants (1196 HIV+, 494 HIV-) in the Women's Interagency HIV Study (WIHS) with data available on anthropometric measures comprise the analytical sample. Cross-sectional analyses using linear regression models estimated the relationship between anthropometric variables and Trails A, Trails B, Stroop interference time, Stroop word recall, Stroop color naming and reading, and Symbol Digit Modalities Test (SDMT) with consideration for age, HIV infection status, Wide Range Achievement Test score, CD4 count, insulin resistance, drug use, and race/ethnicity. Results Among HIV+ women, BMI mid-life with chronic (at least 10 years) HIV infection, common anthropometric measures, primarily BMI, were differentially related to cognitive test performance by cognitive domain. Higher levels of BMI were associated with better cognitive function. In this era of antiretroviral therapies, restoration of health evidenced as higher BMI due to effective antiretroviral therapies, may improve cognitive function in middle-aged HIV infected women. PMID:24338243

  11. Effect of green tea catechins with or without caffeine on anthropometric measures: a systematic review and meta-analysis.

    Science.gov (United States)

    Phung, Olivia J; Baker, William L; Matthews, Leslie J; Lanosa, Michael; Thorne, Alicia; Coleman, Craig I

    2010-01-01

    Green tea catechins (GTCs) with or without caffeine have been studied in randomized controlled trials (RCTs) for their effect on anthropometric measures and have yielded conflicting results. The objective was to perform a systematic review and meta-analysis of RCTs of GTCs on anthropometric variables, including body mass index (BMI), body weight, waist circumference (WC), and waist-to-hip ratio (WHR). A systematic literature search of MEDLINE, EMBASE, CENTRAL, and the Natural Medicines Comprehensive Database was conducted through April 2009. RCTs that evaluated GTCs with or without caffeine and that reported BMI, body weight, WC, or WHR were included. The weighted mean difference of change from baseline (with 95% CIs) was calculated by using a random-effects model. Fifteen studies (n = 1243 patients) met the inclusion criteria. On meta-analysis, GTCs with caffeine decreased BMI (-0.55; 95% CI: -0.65, -0.40), body weight (-1.38 kg; 95% CI: -1.70, -1.06), and WC (-1.93 cm; 95% CI: -2.82, -1.04) but not WHR compared with caffeine alone. GTC ingestion with caffeine also significantly decreased body weight (-0.44 kg; 95% CI: -0.72, -0.15) when compared with a caffeine-free control. Studies that evaluated GTCs without concomitant caffeine administration did not show benefits on any of the assessed anthropometric endpoints. The administration of GTCs with caffeine is associated with statistically significant reductions in BMI, body weight, and WC; however, the clinical significance of these reductions is modest at best. Current data do not suggest that GTCs alone positively alter anthropometric measurements.

  12. Measurer’s Handbook: US Army and Marine Corps Anthropometric Surveys, 2010-2011

    Science.gov (United States)

    2011-08-01

    Center of the navel and its posterior and lateral extensions. PROCEDURE: Participant is in the anthropometric standing position. Stand in front of...drawn at the maximum point of quiet respiration. On heavy participants, the navel may point downward, instead of anteriorly. On such participants...UNCLASSIFIED 6.4.29 Crotch Length (Omphalion) DESCRIPTION: The distance between the abdomen at the level of the center of the navel (omphalion) to the

  13. The Relation of Q Angle and Anthropometric Measures with Ankle Sprain; a Case-control study

    Directory of Open Access Journals (Sweden)

    Hamid Zamani Moghadam

    2017-01-01

    Full Text Available Introduction: Since most studies on ankle sprain are medical and sports-related and not much epidemiologic and etiologic data from the general population exist in this field, the present study evaluates the relationship between Q angle and anthropometric measures with ankle sprain in the general population.Methods: In the present case-control study, all of the patients over 18 years age presenting to emergency departments (ED of two educational Hospitals, complaining from ankle sprain, were evaluated during more than 1 year. A checklist consisting of demographic data, height, weight, body mass index (BMI, and history of ankle sprain, as well as degree of Q angle was filled for all participants. The correlation of mentioned variables with incidence of ankle sprain was calculated using SPSS 22.Results: 300 patients with ankle sprain were evaluated (53.5% male. Mean age of the patients was 37.03 ± 14.20 years. Mean weight, height, and BMI were 71.71 ± 11.26 (43 – 114, 168.74 ± 8.63 (143 – 190 and 25.14 ± 3.19 (18.41 – 38.95, respectively. Mean Q angle of the patients was 12.78 ± 3.19 degrees (5 – 23. There was a significant correlation between weight (p < 0.001, BMI (p = 0.001, history of sprain (r: 0.26, p < 0.001 and Q angle (p = 0.002 with incidence of ankle sprain. In addition, there was a significant statistical correlation between weight (p = 0.031, BMI (p = 0.020 and Q angle (p = 0.004 with history of ankle sprain. In patients with a history of ankle sprain, Q angle was wider by about 2 degrees.Conclusion: It seems that the prevalence of ankle sprain directly correlates with high weight, BMI, and Q angle and is more prevalent in those with a history of sprain. Although the findings of the present study show a statistically significant correlation between these factors and ankle sprain, the correlation is not clinically significant.

  14. Sensitivity of the Combination of Mallampati Scores with Anthropometric Measurements and the Presence of Malignancy to Predict Difficult Intubation

    Science.gov (United States)

    Kandemir, Tünay; Şavlı, Serpil; Ünver, Süheyla; Kandemir, Erbin

    2015-01-01

    Objective The aim of this study was to determine the combinations of the Mallampati test and anthropometric measurements with the highest selectivity value. In addition, we aim to identify a possible correlation between head circumference measurement, the presence of malignancy and difficult intubation. Methods Patients who were scheduled to undergo elective surgery under general anaesthesia, who fell into Group 1–2 according to ASA criteria and were between the ages of 18–70 years were included in the study. Patients with Cormack-Lehane scores of 3–4 were considered to be difficult intubations. Thyromental distance, sternomental distance, mandibular distance, neck length, neck circumference and head circumference were measured during the anthropometric measurements. Results According to the ROC analysis, there was a significant difference in the thyromental distance, sternomental distance, neck length, neck circumference and head circumference between the easy and difficult intubation groups (p<0.05). The incidence of difficult intubation was 8.3% in patients with non-head-neck malignancies, whereas the incidence was 7.1% in patients without any malignancies. The difference between these groups was not statistically significant (χ2=0.101; p=0.751). Conclusion To predict the incidence of difficult intubation, the test with the highest selectivity and highest positive predictive values was the combination of Mallampati-thyromental distance. We believe that the head circumference and neck length measurement, in addition to the current anthropometric measurements, may be crucial to predict the incidence of difficult intubations. In addition, we believe that the anticipation of difficult intubations in patients with non-head-neck malignancies is not different from the normal population. PMID:27366457

  15. The Relationship of Static Anthropometric Measurements to Lower Leg, Ankle, and Foot Injuries in Air Force Academy Cadets: A Prospective Longitudinal Study

    National Research Council Canada - National Science Library

    McMahon, Thomas

    2001-01-01

    The purpose of this prospective cohort study was to investigate the relationship between static anthropometric measures or demographical information and overuse injuries in the lower leg, ankle and foot...

  16. Anthropometric midarm measurements can detect systemic fat-free mass depletion in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    F.F. Sanchez

    2011-05-01

    Full Text Available Our objective was to determine whether anthropometric measurements of the midarm (MA could identify subjects with whole body fat-free mass (FFM depletion. Fifty-five patients (31% females; age: 64.6 ± 9.3 years with mild/very severe chronic obstructive pulmonary disease (COPD, 18 smokers without COPD (39% females; age: 49.0 ± 7.3 years and 23 never smoked controls (57% females; age: 48.2 ± 9.6 years were evaluated. Spirometry, muscle strength and MA circumference were measured. MA muscle area was estimated by anthropometry and MA cross-sectional area by computerized tomography (CT scan. Bioelectrical impedance was used as the reference method for FFM. MA circumference and MA muscle area correlated with FFM and biceps and triceps strength. Receiver operating characteristic curve analysis showed that MA circumference and MA muscle area cut-off points presented sensitivity and specificity >82% to discriminate FFM-depleted subjects. CT scan measurements did not provide improved sensitivity or specificity. For all groups, there was no significant statistical difference between MA muscle area [35.2 (29.3-45.0 cm²] and MA cross-sectional area values [36.4 (28.5-43.3 cm²] and the linear correlation coefficient between tests was r = 0.77 (P < 0.001. However, Bland-Altman plots revealed wide 95% limits of agreement (-14.7 to 15.0 cm² between anthropometric and CT scan measurements. Anthropometric MA measurements may provide useful information for identifying subjects with whole body FFM depletion. This is a low-cost technique and can be used in a wider patient population to identify those likely to benefit from a complete body composition evaluation.

  17. A comparison of measured versus self-reported anthropometrics for assessing obesity in adults: a literature review.

    Science.gov (United States)

    Maukonen, Mirkka; Männistö, Satu; Tolonen, Hanna

    2018-03-01

    Up-to-date information on the accuracy between different anthropometric data collection methods is vital for the reliability of anthropometric data. A previous review on this matter was conducted a decade ago. Our aim was to conduct a literature review on the accuracy of self-reported height, weight, and body mass index (BMI) against measured values for assessing obesity in adults. To obtain an overview of the present situation, we included studies published after the previous review. Differences according to sex, BMI groups, and continents were also assessed. Studies published between January 2006 and April 2017 were identified from a literature search on PubMed. Our search retrieved 62 publications on adult populations that showed a tendency for self-reported height to be overestimated and weight to be underestimated when compared with measured values. The findings were similar for both sexes. BMI derived from self-reported height and weight was underestimated; there was a clear tendency for underestimation of overweight (from 1.8%-points to 9.8%-points) and obesity (from 0.7%-points to 13.4%-points) prevalence by self-report. The bias was greater in overweight and obese participants than those of normal weight. Studies conducted in North America showed a greater bias, whereas the bias in Asian studies seemed to be lower than those from other continents. With globally rising obesity rates, accurate estimation of obesity is essential for effective public health policies to support obesity prevention. As self-report bias tends to be higher among overweight and obese individuals, measured anthropometrics provide a more reliable tool for assessing the prevalence of obesity.

  18. Associations of sedentary behaviour, physical activity, blood pressure and anthropometric measures with cardiorespiratory fitness in children with cerebral palsy.

    Science.gov (United States)

    Ryan, Jennifer M; Hensey, Owen; McLoughlin, Brenda; Lyons, Alan; Gormley, John

    2015-01-01

    Children with cerebral palsy (CP) have poor cardiorespiratory fitness in comparison to their peers with typical development, which may be due to low levels of physical activity. Poor cardiorespiratory fitness may contribute to increased cardiometabolic risk. The aim of this study was to determine the association between sedentary behaviour, physical activity and cardiorespiratory fitness in children with CP. An objective was to determine the association between cardiorespiratory fitness, anthropometric measures and blood pressure in children with CP. This study included 55 ambulatory children with CP [mean (SD) age 11.3 (0.2) yr, range 6-17 yr; Gross Motor Function Classification System (GMFCS) levels I and II]. Anthropometric measures (BMI, waist circumference and waist-height ratio) and blood pressure were taken. Cardiorespiratory fitness was measured using a 10 m shuttle run test. Children were classified as low, middle and high fitness according to level achieved on the test using reference curves. Physical activity was measured by accelerometry over 7 days. In addition to total activity, time in sedentary behaviour and light, moderate, vigorous, and sustained moderate-to-vigorous activity (≥10 min bouts) were calculated. Multiple regression analyses revealed that vigorous activity (β = 0.339, pactivity (β = 0.250, pactivity (β = 0.238, pactivity than children with middle fitness (pblood pressure (r2 = -0.306, pphysical activity, particularly at a vigorous intensity, is associated with high cardiorespiratory fitness in children with CP. Low cardiorespiratory fitness is associated with increased cardiometabolic risk.

  19. Anthropometric indices

    DEFF Research Database (Denmark)

    Oguoma, V. M.; Nwose, E. U.; Skinner, T. C.

    2016-01-01

    BACKGROUND: The current anthropometric indices used for diagnosis of cardio-metabolic syndrome (CMS) in sub-Saharan Africa are those widely validated in the western world. We hereby aim to compare the sensitivity and specificity of these tools in identifying risk factors for CMS. METHOD: The study...

  20. The association between primary tooth emergence and anthropometric measures in young adults: findings from a large prospective cohort study.

    Science.gov (United States)

    Fatemifar, Ghazaleh; Evans, David M; Tobias, Jonathan H

    2014-01-01

    Cross sectional studies suggest a link may exist between tooth emergence and obesity. To explore this relationship, we aimed to evaluate the prospective associations between primary tooth emergence and anthropometric measures in young adults. Multivariable linear regression was used to analyse relationships between primary tooth emergence, and anthropometric measures measured at 17.8 years, in 2977 participants (1362 males and 1615 females) from the Avon Longitudinal Study of Parents and Children (ALSPAC). In minimally adjusted models, 'quintiles of number of paired teeth' (assessed by questionnaire at 15 months) was positively associated with height [change in height (cm) per quintile increase in 'number of paired teeth' (β) = 0.35 (95%CI: 0.18, 0.52) P = 0.0001] and weight [ratio of geometric mean weight per quintile increase in 'number of paired teeth' (RGM) = 1.015 (95%CI: 1.010, 1.019) PPrimary tooth emergence is associated with subsequent fat mass, suggesting these could share common constitutive factors, and that early primary tooth emergence may represent a hitherto unrecognised risk factor for the development of obesity in later life.

  1. Simple anthropometric measures correlate with metabolic risk indicators as strongly as magnetic resonance imaging-measured adipose tissue depots in both HIV-infected and control subjects.

    Science.gov (United States)

    Scherzer, Rebecca; Shen, Wei; Bacchetti, Peter; Kotler, Donald; Lewis, Cora E; Shlipak, Michael G; Heymsfield, Steven B; Grunfeld, Carl

    2008-06-01

    Studies in persons without HIV infection have compared percentage body fat (%BF) and waist circumference as markers of risk for the complications of excess adiposity, but only limited study has been conducted in HIV-infected subjects. We compared anthropometric and magnetic resonance imaging (MRI)-based adiposity measures as correlates of metabolic complications of adiposity in HIV-infected and control subjects. The study was a cross-sectional analysis of 666 HIV-positive and 242 control subjects in the Fat Redistribution and Metabolic Change in HIV Infection (FRAM) study assessing body mass index (BMI), waist (WC) and hip (HC) circumferences, waist-to-hip ratio (WHR), %BF, and MRI-measured regional adipose tissue. Study outcomes were 3 metabolic risk variables [homeostatic model assessment (HOMA), triglycerides, and HDL cholesterol]. Analyses were stratified by sex and HIV status and adjusted for demographic, lifestyle, and HIV-related factors. In HIV-infected and control subjects, univariate associations with HOMA, triglycerides, and HDL were strongest for WC, MRI-measured visceral adipose tissue, and WHR; in all cases, differences in correlation between the strongest measures for each outcome were small (r HDL, WC appeared to be the best anthropometric correlate of metabolic complications, whereas, for triglycerides, the best was WHR. Relations of simple anthropometric measures with HOMA, triglycerides, and HDL cholesterol are approximately as strong as MRI-measured whole-body adipose tissue depots in both HIV-infected and control subjects.

  2. Simple anthropometric measures correlate with metabolic risk indicators as strongly as magnetic resonance imaging–measured adipose tissue depots in both HIV-infected and control subjects2

    Science.gov (United States)

    Scherzer, Rebecca; Shen, Wei; Bacchetti, Peter; Kotler, Donald; Lewis, Cora E; Shlipak, Michael G; Heymsfield, Steven B

    2008-01-01

    Background Studies in persons without HIV infection have compared percentage body fat (%BF) and waist circumference as markers of risk for the complications of excess adiposity, but only limited study has been conducted in HIV-infected subjects. Objective We compared anthropometric and magnetic resonance imaging (MRI)–based adiposity measures as correlates of metabolic complications of adiposity in HIV-infected and control subjects. Design The study was a cross-sectional analysis of 666 HIV-positive and 242 control subjects in the Fat Redistribution and Metabolic Change in HIV Infection (FRAM) study assessing body mass index (BMI), waist (WC) and hip (HC) circumferences, waist-to-hip ratio (WHR), %BF, and MRI-measured regional adipose tissue. Study outcomes were 3 metabolic risk variables [homeostatic model assessment (HOMA), triglycerides, and HDL cholesterol]. Analyses were stratified by sex and HIV status and adjusted for demographic, lifestyle, and HIV-related factors. Results In HIV-infected and control subjects, univariate associations with HOMA, triglycerides, and HDL were strongest for WC, MRI-measured visceral adipose tissue, and WHR; in all cases, differences in correlation between the strongest measures for each outcome were small (r ≤ 0.07). Multivariate adjustment found no significant difference for optimally fitting models between the use of anthropometric and MRI measures, and the magnitudes of differences were small (adjusted R2 ≤ 0.06). For HOMA and HDL, WC appeared to be the best anthropometric correlate of metabolic complications, whereas, for triglycerides, the best was WHR. Conclusion Relations of simple anthropometric measures with HOMA, triglycerides, and HDL cholesterol are approximately as strong as MRI-measured whole-body adipose tissue depots in both HIV-infected and control subjects. PMID:18541572

  3. Effectiveness of a bioactive food compound in anthropometric measures of individuals with HIV/AIDS: A nonrandomized trial.

    Directory of Open Access Journals (Sweden)

    Rosângela Dos Santos Ferreira

    Full Text Available Highly Active Antiretroviral therapy (HAART promotes anthropometric changes in lipid metabolism and glucose in patients with Human Immunodeficiency Virus (HIV. Functional foods play an important role on metabolism. Bioactive Food Compound (BFC has shown effective results in changes arising from decompensated lipid metabolism due to the effects of HAART on HIV patients. From this perspective, the objective of this study is to evaluate anthropometric indicators and the body composition of patients undergoing HAART before and after consumption of BFC.This is a prospective intervention with 180 individuals with HIV undergoing HAART. They formed two groups and were monitored for 3 months: the first group consisted of individuals who consumed BFC (n = 121 at the recommended daily intake of 40 g. The second group consisted of individuals who did not consume BFC (n = 59. We determined body mass index (BMI, waist circumference (WC, waist-hip ratio (WHR, conicity index (CI and antiretroviral regimen used by the patients.The BMI among adults (p<0.001, the WC (p<0.001 and p<0.014 for men and women, respectively and the CI (p = 0.001 and p<0.001 for men and women, respectively increased at the end of the study in the group of individuals who did not consume BFC and remained stable in the BFC group. There were no changes in WHR in any of the groups evaluated. Regarding the antiretroviral regimens used, we observed that there was no difference between regimens as for BMI, WC, WHR and CI.The BFC consumed by HIV patients undergoing HAART allowed the maintenance of anthropometric measures without increasing the mean values of conicity index, suggesting that the consumption of this bioactive compound protects the individual against the development of metabolic syndrome (MeS in patients infected with HIV undergoing antiretroviral therapy.

  4. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    Directory of Open Access Journals (Sweden)

    Sepide Mahluji

    2013-02-01

    Full Text Available Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropometric measurements (body mass index (BMI, weight and waist circumference were recorded before and at the end of study. Lipid profile biomarkers and fasting blood glucose were determined using enzymatic procedure. Analysis of Covariance (ANCOVA test was run to compare the post-treatment values of the two groups, and t-test was conducted to compare within group changes. Results: Serum zinc concentration was increased significantly in intervention group (p=0.024. BMI and body weight was significantly decreased (p=0.030 and p=0.020, respectively. Lipid profile biomarkers and fating blood glucose did not change significantly but triglyceride level was significantly decreased (p=0.006 in the intervention group. Conclusion: The obtained results indicate that zinc supplementation improves BMI, body weight, and triglyceride concentration without considerable effects on lipid profile and glucose level. Zinc can be suggested as a suitable supplementation therapy for obese people, but more studies are needed to verify the results.

  5. Relationship of anthropometric measures with bone mineral density in postmenopausal non-osteoporotic, osteopenic and osteoporotic women

    International Nuclear Information System (INIS)

    Tariq, S.; Lone, K.P.

    2017-01-01

    Body mass index (BMI) has been shown to be a more important predictor of bone mineral density (BMD). The objective of this study was to investigate the relationship of anthropometric measures including body mass index with bone mineral density in postmenopausal non-osteoporotic, osteopenic and osteoporotic women. Methods: In this cross sectional study postmenopausal females between 50-70 years of age were recruited and divided into three groups: non-osteoporotic (n=52), osteopenic (n=69) and osteoporotic females (n=47). Anthropometric measures and bone mineral density were assessed. ANOVA was applied to compare groups while Post hoc Tuckey's test was used for multiple comparisons between the groups. Spearman's rho correlation was used to establish correlations. Results: Body mass index (p = 0.034) and hip circumference (p = 0.013) were significantly higher in osteopenic as compared to osteoporotic females and waist to hip ratio was significantly higher (p = 0.005) in osteoporotic as compared to non-osteoporotic females. Significant positive correlation of body mass index was found with T-score (p = 0.022) and ultrasound bone profile index (p< 0.001) in postmenopausal females. Conclusion: High body mass index is associated with high bone mineral density and reduced fracture risk in postmenopausal females. Increasing age and high waist to hip ratio can also lead to reduced bone mineral density in postmenopausal females. (author)

  6. Relationship of anthropometric measures with bone mineral density in postmenopausal non-osteoporotic, osteopenic and osteoporotic women.

    Science.gov (United States)

    Tariq, Sundus; Tariq, Saba; Lone, Khalid Parvez

    2017-04-01

    Body mass index (BMI) has been shown to be a more important predictor of bone mineral density (BMD). The objective of this study was to investigate the relationship of anthropometric measures including body mass index with bone mineral density in postmenopausal non-osteoporotic, osteopenic and osteoporotic women. In this cross sectional study postmenopausal females between 50-70 years of age were recruited and divided into three groups: non-osteoporotic (n=52), osteopenic (n=69) and osteoporotic females (n=47). Anthropometric measures and bone mineral density were assessed. ANOVA was applied to compare groups while Post hoc Tuckey's test was used for multiple comparisons between the groups. Spearman's rho correlation was used to establish correlations. Body mass index (p = 0.034) and hip circumference (p = 0.013) were significantly higher in osteopenic as compared to osteoporotic females and waist to hip ratio was significantly higher (p = 0.005) in osteoporotic as compared to non-osteoporotic females. Significant positive correlation of body mass index was found with T-score (p = 0.022) and ultrasound bone profile index (p< 0.001) in postmenopausal females. High body mass index is associated with high bone mineral density and reduced fracture risk in postmenopausal females. Increasing age and high waist to hip ratio can also lead to reduced bone mineral density in postmenopausal females.

  7. Conformity of pre-gestational weight measurement and agreement of anthropometric data reported by pregnant women and those recorded in prenatal cards, City of Rio de Janeiro, 2007-2008.

    Science.gov (United States)

    Niquini, Roberta Pereira; Bittencourt, Sonia Azevedo; Leal, Maria do Carmo

    2013-09-01

    To assess the conformity of the weight measurement process in the pre-gestational care offered in the city of Rio de Janeiro by primary units and hospitals of the National Health System, as well as to verify the agreement between the anthropometric data reported by pregnant women and those recorded in prenatal cards. A cross-sectional study was conducted in 2007 - 2008 with two cluster samples: one to obtain a sample of pregnant women to be interviewed and another one for the weight measurement procedures to be observed. The conformity of the weight measurement process was evaluated according to the Ministry of Health standards, and the agreement between the two sources of anthropometric data was evaluated using mean differences, Bland-Altman method, intraclass correlation coefficient (ICC) and weighted Kappa. Out of the twelve criteria for weight measurement evaluation (n = 159 observations), three weren't in conformity (conformity), two of them only need to be assessed when the scale is mechanical. For the interviewed pregnant women (n = 2,148), who had the two sources of anthropometric data, there was a tendency of self-reported height overestimation and pre-gestational and current weight and Body Mass Index underestimation. Accordance between the two sources of anthropometric information, according to ICC and weighted Kappa, were high (> 0.80). Studies may use weight and height information reported by pregnant women, in the absence of prenatal cards records, when it is an important economy to their execution, although the improvement of these two sources of information by means of better anthropometric process is necessary.

  8. Anthropometric measurements in childhood and prediction of cardiovascular risk factors in adulthood: Kaunas cardiovascular risk cohort study.

    Science.gov (United States)

    Petkeviciene, Janina; Klumbiene, Jurate; Kriaucioniene, Vilma; Raskiliene, Asta; Sakyte, Edita; Ceponiene, Indre

    2015-03-04

    This study aimed to examine the associations between anthropometric measurements in childhood and adulthood as well as the effect of childhood body mass index (BMI) and skinfold thickness in the prediction of adult cardiovascular risk factors. The Study subjects were participants of the Kaunas Cardiovascular Risk Cohort study. They were 12-13 years old at the time of the baseline survey (1977) and 48-49 years old in the 35-year follow-up survey (2012, n = 506). In childhood, height, weight, subscapular and triceps skinfold thickness measurements were taken. In 2012, health examination involved measurements of blood pressure (BP), BMI, waist circumference, glucose, lipids, and high-sensitivity C-reactive protein (CRP) levels. Logistic regression models were fitted to assess the associations of childhood BMI and skinfold thicknesses as well as BMI gain with cardiovascular risk factors in middle age. All logistic regression models were adjusted for sex, physical activity level, alcohol consumption, smoking and family history of obesity. Over 35 years of follow-up, BMI gain was greater in men than in women. Anthropometric measurements in childhood significantly correlated with values measured in adulthood. The highest correlation coefficients were defined for weight and BMI measurements (in girls r = 0.56 and r = 0.51 respectively; in boys r = 0.45 and r = 0.41 respectively, P risk of adult obesity, metabolic syndrome, hyperglycaemia or type 2 diabetes, and elevated level of high-sensitivity CRP increased with a rise in childhood BMI and skinfold thicknesses, irrespectively of BMI gain from childhood to adulthood. No relationship was found between childhood anthropometric measurements and arterial hypertension, raised level of triglycerides or reduced level of HDL cholesterol. Gain in BMI from childhood to adulthood was associated with increased odds of all above-mentioned risk factors independently of childhood BMI. Risk of metabolic syndrome

  9. Relationship of constipation and irritable bowel syndrome with food intake, anthropometric measurements and eating behaviors in male students

    Directory of Open Access Journals (Sweden)

    Shafigh Ghaderpour

    2015-09-01

    Full Text Available Background and Objectives: Gastrointestinal disorders like irritable bowel syndrome (IBS and constipation can affect the quality of life and various factors play a role in these disorders. The aim of this study was to investigate the environmental factors related to these problems among Iranian male university students. Materials and Methods: The study was conducted on 186 male students at Ahvaz Jundishapur University of Medical Sciences. Rome Criteria III (to identify gastrointestinal disorders, Dutch eating behavior, food pattern brief instrument and international physical activity questionnaires were completed by all participants moreover, their anthropometric measurements were taken. Results: The results showed a significant difference in weight, body mass index (BMI, waist circumference, hip circumference, and waist to hip ratio in the students suffering from constipation compared with the healthy ones. The students with constipation had more significant milk intake and those with IBS had less intake of vegetables. No significant differences were observed in the eating behavior of students with constipation and IBS, and the healthy ones. Conclusions: Weight and other anthropometric indices could be considered as factors related to constipation. According to the results, an appropriate and balanced intake of different food groups with emphasis on vegetables, milk and dairy products could be recommended. Keywords: Irritable bowel syndrome (IBS, Constipation, Diet, Anthropometry

  10. Acculturation and changes in dietary behavior and anthropometric measures among Chinese international students in South Korea.

    Science.gov (United States)

    Lee, Jounghee; Gao, Ran-Ran; Kim, Jung-Hee

    2015-06-01

    International students face dissimilar food environments, which could lead to changes in dietary behaviors and anthropometric characteristics between before and after migration. We sought to examine the risk factors, including dietary behaviors, acculturation, and demographic characteristics, related to overweight subjects residing in South Korea. We conducted a cross-sectional study, collecting data from 142 Chinese international students (63 males, 79 females) in 2013. The mean age of the subjects was 25.4 years, and almost half of them immigrated to South Korea to earn a master's degree or doctoral degree (n = 70, 49.3%). Chinese international students showed an increase in skipping meals and eating speed, but a decrease in the frequency of fruit and vegetable consumption in South Korea compared to when they lived in China. We found a statistically significant increase in weight (69.4 → 73.9 kg) and BMI (22.4 → 23.8 kg/m(2)) for male subjects (P < 0.001) but no change for female subjects. We also found that overweight subjects were more likely to be highly acculturated and male compared with normal-weight subjects. Among Chinese international students living in South Korea, male and more highly acculturated subjects are more vulnerable to weight gain. This study provides useful information to design tailored nutrition intervention programs for Chinese international students.

  11. Effect of hand volume and other anthropometric measurements on carpal tunnel syndrome.

    Science.gov (United States)

    Arslan, Yıldız; Bülbül, İsmail; Öcek, Levent; Şener, Ufuk; Zorlu, Yaşar

    2017-04-01

    Carpal tunnel syndrome (CTS), majority of cases are considered to be idiopathic, is the most commonly encountered peripheral neuropathy causing disability. We asserted that thick and big hands may more prone to idiopathic CTS (ICTS) than others. The study included 165 subjects admitted to our electrophysiology lab with pre-diagnosis of CTS between May 2014 and April 2015. Eighty-five of the subjects were diagnosed as ICTS. The parameters analyzed were: age, gender, occupation, BMI, hand dominance, grade of ICTS, wrist circumference, proximal/distal width of palm, hand/palm length, hand volume and palm length/proximal palm width. Female gender was significantly higher in both groups. The mean age of study group was 44.02 ± 9.11 years, and control group was 41.25 ± 9.94 years. BMI, wrist circumference and hand volume were significantly higher in the study group (p ICTS. Higher hand volume, wrist circumference and lower palm length/prox. palm width ratio can also be anthropometric risk factors. Large hand volumes, big and coarse hands are more prone to ICTS.

  12. Levels of DDT and its metabolites in placenta, maternal and cord blood and their potential influence on neonatal anthropometric measures

    International Nuclear Information System (INIS)

    Al-Saleh, Iman; Al-Doush, Inaam; Alsabbaheen, Ammar; Mohamed, Gamal El Din; Rabbah, Abdullah

    2012-01-01

    Previous studies of in utero exposure to dichlorodiphenyltrichloroethane (DDT) have shown mixed results for the harmful effects on fetal growth and development. This cross-sectional study was designed to: (1) examine the extent of DDT exposure in 1578 women, aged 28.5 ± 6.0 who delivered between June 2005 and 2006 in the area of Al-Kharj, Saudi Arabia; and (2) assess its influence on neonatal anthropometric measurement of newly born babies. DDT and its metabolites, namely 1,1-dichloro-2,2-bis (p-chlorophenyl) ethylene (p,p′-DDE), 1,1-dichloro-2,2-bis (p-chlorophenyl) ethane (p,p′-DDD) and 1,1,1-trichloro-2,2′ bis (p-chlorophenyl) ethane (p,p′-DDT) were measured in cord and maternal serum as well as placenta by Gas Chromatography coupled with an Electron Capture Detector (GC/ECD). p,p′-DDE was detected in 28.3% of cord and 54.4% of maternal serum, reflecting past exposure, whereas the p,p′-DDT was only found in 0.46% cord and 1.2% maternal samples. As expected the p,p′-DDE cord levels (0.197 ± 0.961 μg/L) were 2.8 times lower than the maternal levels (0.551 ± 1.778 μg/L), and both were significantly correlated (r = 0.517) suggesting its transplacental transfer. The picture was different in placental tissues. p,p′-DDE and p,p′-DDT were detected in 84% and 99% of placental tissues, with the highest p,p′-DDT in placental tissues (29.62 ± 158.282 µg/kg dry wt.) compare to p,p′-DDE (10.167 ± 18.851 μg/kg dry wt.). In general, the presence of DDT metabolites in our participants indicates that these chemicals are still relevant despite the fact that they have been banned or restricted in the study area for many years. Our results support the view for an association between low in utero exposure to DDT and the anthropometric development of the fetus leading to a reduction in its head circumference, crown–heel length, birth weight and birth height. Since the reduction in these measures was independent of gestational age and/or preterm births

  13. Levels of DDT and its metabolites in placenta, maternal and cord blood and their potential influence on neonatal anthropometric measures

    Energy Technology Data Exchange (ETDEWEB)

    Al-Saleh, Iman, E-mail: iman@kfshrc.edu.sa [Environmental Health Section, Biological and Medical Research Department, King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh (Saudi Arabia); Al-Doush, Inaam; Alsabbaheen, Ammar [Environmental Health Section, Biological and Medical Research Department, King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh (Saudi Arabia); Mohamed, Gamal El Din [Biostatistics, Epidemiology and Scientific Computing Department, King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh (Saudi Arabia); Rabbah, Abdullah [Department of Pediatrics, King Khalid Hospital, Al-Kharj (Saudi Arabia)

    2012-02-01

    Previous studies of in utero exposure to dichlorodiphenyltrichloroethane (DDT) have shown mixed results for the harmful effects on fetal growth and development. This cross-sectional study was designed to: (1) examine the extent of DDT exposure in 1578 women, aged 28.5 {+-} 6.0 who delivered between June 2005 and 2006 in the area of Al-Kharj, Saudi Arabia; and (2) assess its influence on neonatal anthropometric measurement of newly born babies. DDT and its metabolites, namely 1,1-dichloro-2,2-bis (p-chlorophenyl) ethylene (p,p Prime -DDE), 1,1-dichloro-2,2-bis (p-chlorophenyl) ethane (p,p Prime -DDD) and 1,1,1-trichloro-2,2 Prime bis (p-chlorophenyl) ethane (p,p Prime -DDT) were measured in cord and maternal serum as well as placenta by Gas Chromatography coupled with an Electron Capture Detector (GC/ECD). p,p Prime -DDE was detected in 28.3% of cord and 54.4% of maternal serum, reflecting past exposure, whereas the p,p Prime -DDT was only found in 0.46% cord and 1.2% maternal samples. As expected the p,p Prime -DDE cord levels (0.197 {+-} 0.961 {mu}g/L) were 2.8 times lower than the maternal levels (0.551 {+-} 1.778 {mu}g/L), and both were significantly correlated (r = 0.517) suggesting its transplacental transfer. The picture was different in placental tissues. p,p Prime -DDE and p,p Prime -DDT were detected in 84% and 99% of placental tissues, with the highest p,p Prime -DDT in placental tissues (29.62 {+-} 158.282 Micro-Sign g/kg dry wt.) compare to p,p Prime -DDE (10.167 {+-} 18.851 {mu}g/kg dry wt.). In general, the presence of DDT metabolites in our participants indicates that these chemicals are still relevant despite the fact that they have been banned or restricted in the study area for many years. Our results support the view for an association between low in utero exposure to DDT and the anthropometric development of the fetus leading to a reduction in its head circumference, crown-heel length, birth weight and birth height. Since the reduction in these

  14. The Impact of Different Anthropometric Measures on Sustained Normotension, White Coat Hypertension, Masked Hypertension, and Sustained Hypertension in Patients with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Baris Afsar

    2013-09-01

    Full Text Available BackgroundMany studies have aimed to determine whether body mass index (BMI, waist circumference (WC, or waist to hip ratio (WHR best predicts hypertension in diabetic patients, with conflicting results. However, no study has examined the specific relationship between these anthropometric parameters with sustained normotension (SNT, white coat hypertension (WCHT, masked hypertension (MHT, and sustained hypertension (SHT based on office and ambulatory blood pressure (BP measurements in these patients.MethodsPatients with newly diagnosed type 2 diabetes underwent the following procedures: history taking, measurements of anthropometric parameters, office and ambulatory BP measurements, physical examination, laboratory analysis, and random and 24-hour urine analysis.ResultsIn total, there were 65 dippers and 37 nondipper patients. None of the anthropometric parameters were different between the dippers and the nondippers. There were 25 patients with SNT, 32 with WCHT, seven with MHT, and 38 with SHT. A comparison of anthropometric parameters between these four groups of patients showed that WC (P=0.016 and WHR (P=0.015 were different among all groups. According to regression analysis, only BMI was independently related with MHT (odds ratio [OR], 1.373, P=0.022, whereas only WC has been associated with SHT (OR, 1.321, P=0.041.ConclusionAmong anthropometric parameters, only WC and WHR were different in SNT, WCHT, MHT, and SHT in newly diagnosed patients with type 2 diabetes.

  15. Genetic and environmental contributions to the association between anthropometric measures and iq: a study of Minnesota twins at age 11 and 17.

    Science.gov (United States)

    Silventoinen, Karri; Iacono, William G; Krueger, Robert; McGue, Matthew

    2012-05-01

    Associations of height and head circumference with IQ are well documented, but much less is known about the association of IQ with other anthropometric measures or the mechanisms behind these associations. We therefore analyzed the associations between IQ and several anthropometric measures using a twin-study design. Twins born in Minnesota were assessed at either age 11 (756 complete pairs) or 17 (626 complete pairs) and analyzed using genetic modeling. Head circumference and height showed the most consistent positive associations with IQ, whereas more detailed anthropometric measures were not significantly better predictors of IQ. These associations were mainly due to common genetic factors. Our results suggest that the same genetic factors have an effect on physical and cognitive development. Head circumference and height capture information on children's physical development, which is partly associated also with cognitive development.

  16. A training program for anthropometric measurements by a dedicated nutrition support team improves nutritional status assessment of the critically ill child.

    Science.gov (United States)

    Valla, Frederic V; Ford-Chessel, Carole; Meyer, Rosan; Berthiller, Julien; Dupenloup, Christine; Follin-Arbelet, Nathalie; Hubert, Anna; Javouhey, Etienne; Peretti, Noel

    2015-03-01

    The cornerstone of an optimal nutrition approach in PICUs is to evaluate the nutritional status of any patient. Anthropometric measurements and nutritional indices calculation allow for nutritional status assessment, which is not often part of routine management, as it is considered difficult to perform in this setting. We designed a study to evaluate the impact of a training program by the PICU nutritional support team on the implementation of routine anthropometric measurements on our PICU. A prospective study was performed over a 2-year period, which included: a baseline evaluation of nutritional assessment, knowledge, anthropometric measurements (weight, height, and head and mid upper arm circumferences), and nutritional indices calculation in patient files. This was followed by a training program to implement the newly developed nutrition assessment guidelines, which included anthropometrical measurements and also the interpretation of these. The impact of this nutritional assessment program was reviewed annually for 2 years after the implementation. PICU--Lyon, France. PICU nursing and medical staff, and patients admitted in February 2011, 2012, and 2013. Training program. Ninety-nine percent of staff (n = 145) attended the individual teaching. We found significant progress in nutritional awareness and confidence about nutritional assessment following the teaching program. In addition, an improvement in staff knowledge about undernutrition and its consequences were found. We enrolled 41, 55, and 91 patients in 2011, 2012, and 2013, respectively. There was a significant increase in anthropometric measurements during this time: 32%, 65% (p = 0.002), and 96% in 2013 (p importance and techniques of anthropometrical measurements has successfully been implemented in a PICU. It managed to improve staff knowledge and nutritional practice.

  17. [Anthropometric study and evaluation of the nutritional status of a population school children in Granada; comparison of national and international reference standards].

    Science.gov (United States)

    González Jiménez, E; Aguilar Cordero, M J; Álvarez Ferre, J; Padilla López, C; Valenza, M C

    2012-01-01

    Recent studies show an alarming increase in levels of overweight and obesity among children and adolescents. The main objectives of this research were the following: (i) to carry out an anthropometric evaluation of the nutritional status and body composition of school children in the city and province of Granada; (ii) to compare the nutritional status of this population sample with national and international reference standards. The results obtained in this study showed that the general prevalence of overweight in both sexes was 22.03% and that 9.12% of the children were obese. Statistically significant differences were found between the variable, weight for age and sex (p < 0.05) and the variable, height for age and sex (p < 0.05). Regarding the body mass index, no statistically significant differences were found for the variable, sex (p = 0.182). This contrasted with the variable, age, which did show statistically significant differences (p < 0.05). As a conclusion, the results of our study highlighted the fact that these anthropometric values were much higher than national and international reference standards.

  18. Anthropometric characteristics and nutritional status of older adults ...

    African Journals Online (AJOL)

    2011-08-27

    Aug 27, 2011 ... used to define undernutrition in men and women respectively.1 TSF values < 12 mm ... between 60-95 years, with a mean ± standard deviation (SD) of 66.1. ± 8.7 years. ... Table I: Means and standard deviations of anthropometric measurements of older adults in the Lake Victoria Basin by region and sex.

  19. The effect of probiotic soy milk and soy milk on anthropometric measures and blood pressure in patients with type II diabetes mellitus: A randomized double-blind clinical trial.

    Science.gov (United States)

    Hariri, Mitra; Salehi, Rasoul; Feizi, Awat; Mirlohi, Maryam; Kamali, Sara; Ghiasvand, Reza

    2015-02-01

    The objective of this clinical trial was to assess the effects of probiotic soy milk and soy milk on anthropometric measures and blood pressure (BP) in type 2 diabetic (T2D) patients. A total of 40 patients with T2D, 35-68 years old, were assigned to two groups in this randomized, double-blind, controlled clinical trial. The patients in the intervention group consumed 200 ml/day of probiotic soy milk containing Lactobacillus planetarium A7 and those in control group consumed 200 ml/day of soy milk for 8 weeks. Anthropometric and BP measurements were performed according to standard protocols. For detecting within-group differences paired-sample t-tests was used and analysis of covariance was used for determining any differences between two groups. (The trial has been registered in the Iranian Registry of Clinical Trials, identifier: IRCT: IRCT201405265062N8). In this study, we failed to find any significant changes between probiotic soy milk and soy milk in term of body mass index (26.65 ± 0.68 vs. 26.33 ± 0.74, P = 0.300) and waist to hip ratio (1.49 ± 0.08 vs. 1.54 ± 0.1, P = 0.170). Although soy milk did not have any effect on BP, probiotic soymilk significantly decreased systolic (14.7 ± 0.48 vs. 13.05 ± 0.16, P = 0.001) and diastolic BP (10 ± 0.7 vs. 9.1 ± 1, P = 0.031). In our study, probiotic soy milk in comparing with soy milk did not have any beneficial effects on anthropometric measures in these patients. We need more clinical trial for confirming the effect of probiotic foods on anthropometric measure in diabetic patients. However, probiotic soy milk decreased systolic and diastolic BP significantly.

  20. Associations of sedentary behaviour, physical activity, blood pressure and anthropometric measures with cardiorespiratory fitness in children with cerebral palsy.

    Directory of Open Access Journals (Sweden)

    Jennifer M Ryan

    Full Text Available Children with cerebral palsy (CP have poor cardiorespiratory fitness in comparison to their peers with typical development, which may be due to low levels of physical activity. Poor cardiorespiratory fitness may contribute to increased cardiometabolic risk.The aim of this study was to determine the association between sedentary behaviour, physical activity and cardiorespiratory fitness in children with CP. An objective was to determine the association between cardiorespiratory fitness, anthropometric measures and blood pressure in children with CP.This study included 55 ambulatory children with CP [mean (SD age 11.3 (0.2 yr, range 6-17 yr; Gross Motor Function Classification System (GMFCS levels I and II]. Anthropometric measures (BMI, waist circumference and waist-height ratio and blood pressure were taken. Cardiorespiratory fitness was measured using a 10 m shuttle run test. Children were classified as low, middle and high fitness according to level achieved on the test using reference curves. Physical activity was measured by accelerometry over 7 days. In addition to total activity, time in sedentary behaviour and light, moderate, vigorous, and sustained moderate-to-vigorous activity (≥10 min bouts were calculated.Multiple regression analyses revealed that vigorous activity (β = 0.339, p<0.01, sustained moderate-to-vigorous activity (β = 0.250, p<0.05 and total activity (β = 0.238, p<0.05 were associated with level achieved on the shuttle run test after adjustment for age, sex and GMFCS level. Children with high fitness spent more time in vigorous activity than children with middle fitness (p<0.05. Shuttle run test level was negatively associated with BMI (r2 = -0.451, p<0.01, waist circumference (r2 = -0.560, p<0.001, waist-height ratio (r2 = -0.560, p<0.001 and systolic blood pressure (r2 = -0.306, p<0.05 after adjustment for age, sex and GMFCS level.Participation in physical activity, particularly at a vigorous intensity, is

  1. Standard-Setting Methods as Measurement Processes

    Science.gov (United States)

    Nichols, Paul; Twing, Jon; Mueller, Canda D.; O'Malley, Kimberly

    2010-01-01

    Some writers in the measurement literature have been skeptical of the meaningfulness of achievement standards and described the standard-setting process as blatantly arbitrary. We argue that standard setting is more appropriately conceived of as a measurement process similar to student assessment. The construct being measured is the panelists'…

  2. Association of Breast Feeding and Birth Weight with Anthropometric Measures and Blood Pressure in Children and Adolescents: The CASPIAN-IV Study

    Directory of Open Access Journals (Sweden)

    Shirin Djalalinia

    2015-10-01

    Conclusion: BW was associated with a higher prevalence in general obesity and a lower prevalence of being underweight. Duration of BF had no significant association with anthropometric measures and BP. Future longitudinal studies are necessary to determine the clinical implications of these findings.

  3. Association of Anthropometric and Bioelectrical Impedance Analysis Measures of Adiposity with High Molecular Weight Adiponectin Concentration.

    Science.gov (United States)

    Zeng, Wei-Fang; Li, Yan; Sheng, Chang-Sheng; Huang, Qi-Fang; Kang, Yuan-Yuan; Zhang, Lu; Wang, Shuai; Cheng, Yi-Bang; Li, Fei-Ka; Wang, Ji-Guang

    2016-01-01

    To investigate the relationship between adiposity measures and plasma concentration of high molecular weight (HMW) adiponectin. In a Chinese sample (n = 1081), we performed measurements of anthropometry and bioelectrical impedance analysis (BIA). We defined overweight and obesity as a body mass index between 24 and 27.4 kg/m² and ≥ 27.5 kg/m², respectively, and central obesity as a waist circumference ≥ 90 cm in men and ≥ 80 cm in women. Plasma HMW adiponectin concentration was measured by the ELISA method. Plasma HMW adiponectin concentration was significantly (P obesity (n = 60, 1.31 μg/mL and n = 82, 2.10 μg/mL, respectively) than normal weight subjects (n = 185, 2.07μg/mL and n = 368, 2.94 μg/mL, respectively) and in the presence of central obesity (n = 106, 1.28 μg/mL and n = 331, 2.12 μg/mL, respectively) than subjects with a normal waist circumference (n = 298, 1.74 μg/mL and n = 346, 2.74 μg/mL, respectively). In multiple regression analyses stratified for gender, adjusted for confounders and considered separately each of the adiposity measures, all adiposity measures were significantly (r -0.18 to -0.31, P obesity, such as waist-to-hip ratio, but not BIA measures, are independently associated with plasma adiponectin concentration.

  4. Measurements, Standards, and the SI.

    Science.gov (United States)

    Journal of Chemical Education, 1983

    1983-01-01

    Highlights six papers presented at the Seventh Biennial Conference on Chemical Education (Stillwater, Oklahoma 1982). Topics addressed included history, status, and future of SI units, algebra of SI units, periodic table, new standard-state pressure unit, and suggested new names for mole concept ("numerity" and "chemical amount"). (JN)

  5. MEASURES REFERENCES OF ABNT: Instrument for the standardization of clothing products

    Directory of Open Access Journals (Sweden)

    Maicon Douglas Livramento Nishimura

    2016-12-01

    Full Text Available In order to standardize the units of clothing measurements, ABNT (Brazilian Association of Technical Standards conducts research for the development of national measures reference in children, male and female segments. The standards of child and male measures are already in place, however, still works for the improvement of a female norm. Regarding the normalization of measures of Brazilian clothing, sought to identify the system methodology adopted for the development of standards of existing measures and to analyze how this information is absorbed by the fashion market. The research was based on bibliographic and documentary survey, considering mainly the standards of Brazilian measures benchmarks and projects these rules had little or no anthropometric study in its methodology. Consequently, it was noticed certain fragility of reference measures currently used, however, the accuracy in sight with the studies that are under development and the possible outcomes that will soon be available for analysis.

  6. The CODATwins Project: The Cohort Description of Collaborative Project of Development of Anthropometrical Measures in Twins to Study Macro-Environmental Variation in Genetic and Environmental Effects on Anthropometric Traits.

    Science.gov (United States)

    Silventoinen, Karri; Jelenkovic, Aline; Sund, Reijo; Honda, Chika; Aaltonen, Sari; Yokoyama, Yoshie; Tarnoki, Adam D; Tarnoki, David L; Ning, Feng; Ji, Fuling; Pang, Zengchang; Ordoñana, Juan R; Sánchez-Romera, Juan F; Colodro-Conde, Lucia; Burt, S Alexandra; Klump, Kelly L; Medland, Sarah E; Montgomery, Grant W; Kandler, Christian; McAdams, Tom A; Eley, Thalia C; Gregory, Alice M; Saudino, Kimberly J; Dubois, Lise; Boivin, Michel; Haworth, Claire M A; Plomin, Robert; Öncel, Sevgi Y; Aliev, Fazil; Stazi, Maria A; Fagnani, Corrado; D'Ippolito, Cristina; Craig, Jeffrey M; Saffery, Richard; Siribaddana, Sisira H; Hotopf, Matthew; Sumathipala, Athula; Spector, Timothy; Mangino, Massimo; Lachance, Genevieve; Gatz, Margaret; Butler, David A; Bayasgalan, Gombojav; Narandalai, Danshiitsoodol; Freitas, Duarte L; Maia, José Antonio; Harden, K Paige; Tucker-Drob, Elliot M; Christensen, Kaare; Skytthe, Axel; Kyvik, Kirsten O; Hong, Changhee; Chong, Youngsook; Derom, Catherine A; Vlietinck, Robert F; Loos, Ruth J F; Cozen, Wendy; Hwang, Amie E; Mack, Thomas M; He, Mingguang; Ding, Xiaohu; Chang, Billy; Silberg, Judy L; Eaves, Lindon J; Maes, Hermine H; Cutler, Tessa L; Hopper, John L; Aujard, Kelly; Magnusson, Patrik K E; Pedersen, Nancy L; Aslan, Anna K Dahl; Song, Yun-Mi; Yang, Sarah; Lee, Kayoung; Baker, Laura A; Tuvblad, Catherine; Bjerregaard-Andersen, Morten; Beck-Nielsen, Henning; Sodemann, Morten; Heikkilä, Kauko; Tan, Qihua; Zhang, Dongfeng; Swan, Gary E; Krasnow, Ruth; Jang, Kerry L; Knafo-Noam, Ariel; Mankuta, David; Abramson, Lior; Lichtenstein, Paul; Krueger, Robert F; McGue, Matt; Pahlen, Shandell; Tynelius, Per; Duncan, Glen E; Buchwald, Dedra; Corley, Robin P; Huibregtse, Brooke M; Nelson, Tracy L; Whitfield, Keith E; Franz, Carol E; Kremen, William S; Lyons, Michael J; Ooki, Syuichi; Brandt, Ingunn; Nilsen, Thomas Sevenius; Inui, Fujio; Watanabe, Mikio; Bartels, Meike; van Beijsterveldt, Toos C E M; Wardle, Jane; Llewellyn, Clare H; Fisher, Abigail; Rebato, Esther; Martin, Nicholas G; Iwatani, Yoshinori; Hayakawa, Kazuo; Rasmussen, Finn; Sung, Joohon; Harris, Jennifer R; Willemsen, Gonneke; Busjahn, Andreas; Goldberg, Jack H; Boomsma, Dorret I; Hur, Yoon-Mi; Sørensen, Thorkild I A; Kaprio, Jaakko

    2015-08-01

    For over 100 years, the genetics of human anthropometric traits has attracted scientific interest. In particular, height and body mass index (BMI, calculated as kg/m2) have been under intensive genetic research. However, it is still largely unknown whether and how heritability estimates vary between human populations. Opportunities to address this question have increased recently because of the establishment of many new twin cohorts and the increasing accumulation of data in established twin cohorts. We started a new research project to analyze systematically (1) the variation of heritability estimates of height, BMI and their trajectories over the life course between birth cohorts, ethnicities and countries, and (2) to study the effects of birth-related factors, education and smoking on these anthropometric traits and whether these effects vary between twin cohorts. We identified 67 twin projects, including both monozygotic (MZ) and dizygotic (DZ) twins, using various sources. We asked for individual level data on height and weight including repeated measurements, birth related traits, background variables, education and smoking. By the end of 2014, 48 projects participated. Together, we have 893,458 height and weight measures (52% females) from 434,723 twin individuals, including 201,192 complete twin pairs (40% monozygotic, 40% same-sex dizygotic and 20% opposite-sex dizygotic) representing 22 countries. This project demonstrates that large-scale international twin studies are feasible and can promote the use of existing data for novel research purposes.

  7. The CODAtwins project: the cohort description of COllaborative project of Development of Anthropometrical measures in Twins to study macro-environmental variation in genetic and environmental effects on anthropometric traits

    Science.gov (United States)

    Silventoinen, Karri; Jelenkovic, Aline; Sund, Reijo; Honda, Chika; Aaltonen, Sari; Yokoyama, Yoshie; Tarnoki, Adam D; Tarnoki, David L; Ning, Feng; Ji, Fuling; Pang, Zengchang; Ordoñana, Juan R; Sánchez-Romera, Juan F; Colodro-Conde, Lucia; Burt, S Alexandra; Klump, Kelly L; Medland, Sarah E; Montgomery, Grant W; Kandler, Christian; McAdams, Tom A; Eley, Thalia C; Gregory, Alice M; Saudino, Kimberly J; Dubois, Lise; Boivin, Michel; Haworth, Claire MA; Plomin, Robert; Öncel, Sevgi Y; Aliev, Fazil; Stazi, Maria A; Fagnani, Corrado; D'Ippolito, Cristina; Craig, Jeffrey M; Saffery, Richard; Siribaddana, Sisira H; Hotopf, Matthew; Sumathipala, Athula; Spector, Timothy; Mangino, Massimo; Lachance, Genevieve; Gatz, Margaret; Butler, David A; Bayasgalan, Gombojav; Narandalai, Danshiitsoodol; Freitas, Duarte L; Maia, José Antonio; Harden, K Paige; Tucker-Drob, Elliot M; Christensen, Kaare; Skytthe, Axel; Kyvik, Kirsten O; Hong, Changhee; Chong, Youngsook; Derom, Catherine A; Vlietinck, Robert F; Loos, Ruth JF; Cozen, Wendy; Hwang, Amie E; Mack, Thomas M; He, Mingguang; Ding, Xiaohu; Chang, Billy; Silberg, Judy L; Eaves, Lindon J; Maes, Hermine H; Cutler, Tessa L; Hopper, John L; Aujard, Kelly; Magnusson, Patrik KE; Pedersen, Nancy L; Dahl-Aslan, Anna K; Song, Yun-Mi; Yang, Sarah; Lee, Kayoung; Baker, Laura A; Tuvblad, Catherine; Bjerregaard-Andersen, Morten; Beck-Nielsen, Henning; Sodemann, Morten; Heikkilä, Kauko; Tan, Qihua; Zhang, Dongfeng; Swan, Gary E; Krasnow, Ruth; Jang, Kerry L; Knafo-Noam, Ariel; Mankuta, David; Abramson, Lior; Lichtenstein, Paul; Krueger, Robert F; McGue, Matt; Pahlen, Shandell; Tynelius, Per; Duncan, Glen E; Buchwald, Dedra; Corley, Robin P; Huibregtse, Brooke M; Nelson, Tracy L; Whitfield, Keith E; Franz, Carol E; Kremen, William S; Lyons, Michael J; Ooki, Syuichi; Brandt, Ingunn; Nilsen, Thomas Sevenius; Inui, Fujio; Watanabe, Mikio; Bartels, Meike; van Beijsterveldt, Toos CEM; Wardle, Jane; Llewellyn, Clare H; Fisher, Abigail; Rebato, Esther; Martin, Nicholas G; Iwatani, Yoshinori; Hayakawa, Kazuo; Rasmussen, Finn; Sung, Joohon; Harris, Jennifer R; Willemsen, Gonneke; Busjahn, Andreas; Goldberg, Jack H; Boomsma, Dorret I; Hur, Yoon-Mi; Sørensen, Thorkild IA; Kaprio, Jaakko

    2015-01-01

    For over one hundred years, the genetics of human anthropometric traits has attracted scientific interest. In particular, height and body mass index (BMI, calculated as kg/m2) have been under intensive genetic research. However, it is still largely unknown whether and how heritability estimates vary between human populations. Opportunities to address this question have increased recently because of the establishment of many new twin cohorts and the increasing accumulation of data in established twin cohorts. We started a new research project to analyze systematically 1) the variation of heritability estimates of height, BMI and their trajectories over the life course between birth cohorts, ethnicities and countries, and 2) to study the effects of birth related factors, education and smoking on these anthropometric traits and whether these effects vary between twin cohorts. We identified 67 twin projects including both monozygotic and dizygotic twins using various sources. We asked for individual level data on height and weight including repeated measurements, birth related traits, background variables, education and smoking. By the end of 2014, 48 projects participated. Together, we have 893,458 height and weight measures (52% females) from 434,723 twin individuals, including 201,192 complete twin pairs (40% monozygotic, 40% same-sex dizygotic and 20% opposite-sex dizygotic) representing 22 countries. This project demonstrates that large-scale international twin studies are feasible and can promote the use of existing data for novel research purposes. PMID:26014041

  8. Validating Neck Circumference and Waist Circumference as Anthropometric Measures of Overweight/Obesity in Adolescents.

    Science.gov (United States)

    Patnaik, Lipilekha; Pattnaik, Sumitra; Rao, E Venkata; Sahu, Trilochan

    2017-05-15

    To measure neck circumference and waist circumference, to compare it between normal and overweight/obese adolescents, and to validate these with body mass index. This cross-sectional study was conducted in 1800 school-going adolescents. Body mass index, waist circumference and neck circumference were measured. Independent samples t-test and Pearson's correlation were used as tests of significance to analyze quantitative data. Positive correlation of neck circumference and waist circumference with body mass index was observed. The neck circumference and waist circumference in overweight/obese adolescents were significantly higher than adolescents with normal body mass index (Padolescent obesity in boys and girls were 30.75 cm, and 29.75 cm, respectively, and waist circumference cut-off value were 70.75 cm for boys and 69.25 cm for girls at fairly good levels of sensitivity and specificity. Neck circumference and waist circumference may be used in clinical practice and epidemiological studies as an index of overweight/ obesity among school-going adolescents.

  9. Apolipoprotein E gene polymorphism and its effect on anthropometric measures in normoglycemic subjects and type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Tabatabaei-Malazy Ozra

    2012-10-01

    Full Text Available Abstract Background Apolipoprotein E (apo E plays a major role in lipid metabolism, obesity and accordingly in development of diabetes and coronary heart disease (CHD. Our main objective was to evaluate the association between apo E gene polymorphism with anthropometric measures. Methods Participants were selected from zone 17 Tehran/Iran. We assessed height, weight, body mass index (BMI, waist circumference (WC, blood pressure, serum fasting blood sugar, total cholesterol and triglycerides. Genotyping for apo E gene polymorphism was carried out using PCR-RFLP technique. Results Among total study population (n=311, 156 subjects were diabetic. The apo E3/E3 was the most common genotype in our population while E2 and E4 alleles had lower frequencies, respectively. After adjustment for diabetes, the apo E2 and E4 alleles were significantly associated with hypercholesterolemia and WC, respectively (p= 0.009, 0.034. This association was also related to sex and age. The probability of having abdominal obesity in E4 allele carriers was increased from 0.22 to 8.12 in women and to 3.08 in age ≥ 50 years. Conclusions Apo E polymorphism had significant influences on WC and total cholesterol level in patients with type 2 diabetes. This study highlights the importance of lifestyle modifications which may be more beneficial in hypercholesterolemic women carriers of E2 and E4 alleles concomitant central obesity.

  10. Anthropometric Measurements of the Human Distal Femur: A Study of the Adult Malay Population

    Science.gov (United States)

    Hussain, Fitdriyah; Abdul Kadir, Mohammed Rafiq; Zulkifly, Ahmad Hafiz; Sa'at, Azlin; Aziz, Azian Abd.; Hossain, Md. Golam; Kamarul, T.; Syahrom, Ardiyansyah

    2013-01-01

    The distal femurs of 100 subjects (50 men, 50 women) from the Malay population aged between 19 and 38 years were scanned to measure the anterior-posterior (AP) and medial-lateral (ML) width. The mean AP values were 64.02 ± 3.38 mm and 57.33 ± 3.26 mm for men and women, respectively, and the mean ML values were 74.91 ± 3.52 mm and 64.53 ± 3.07 mm. We compared our data to that published previously for the Chinese and Indian populations. It was found that the Malay population had smaller distal femur than that of the Chinese but was larger than that of the Indian population (P population, the variations in different Asian ethnicities may need to be considered when designing the appropriate knee implant. PMID:24294597

  11. Comparison of measured and self-reported anthropometric information among firefighters: implications and applications

    Science.gov (United States)

    Hsiao, Hongwei; Weaver, Darlene; Hsiao, James; Whitestone, Jennifer; Kau, Tsui-Ying; Whisler, Richard; Ferri, Robert

    2016-01-01

    This study evaluated the accuracy of self-reported body weight and height compared to measured values among firefighters and identified factors associated with reporting error. A total of 863 male and 88 female firefighters in four US regions participated in the study. The results showed that both men and women underestimated their body weight (−0.4 ± 4.1, −1.1 ± 3.6 kg) and overestimated their height (29 ± 18, 17 ± 16 mm). Women underestimated more than men on weight (p = 0.022) and men overestimated more than women on height (p < 0.001). Reporting errors on weight were increased with overweight status (p < 0.001) and were disproportionate among subgroups. About 27% men and 24% women had reporting errors on weight greater than ± 2.2 kg, and 59% men and 28% women had reporting errors on height greater than 25 mm. PMID:25198061

  12. Single camera multi-view anthropometric measurement of human height and mid-upper arm circumference using linear regression.

    Science.gov (United States)

    Liu, Yingying; Sowmya, Arcot; Khamis, Heba

    2018-01-01

    Manually measured anthropometric quantities are used in many applications including human malnutrition assessment. Training is required to collect anthropometric measurements manually, which is not ideal in resource-constrained environments. Photogrammetric methods have been gaining attention in recent years, due to the availability and affordability of digital cameras. The primary goal is to demonstrate that height and mid-upper arm circumference (MUAC)-indicators of malnutrition-can be accurately estimated by applying linear regression to distance measurements from photographs of participants taken from five views, and determine the optimal view combinations. A secondary goal is to observe the effect on estimate error of two approaches which reduce complexity of the setup, computational requirements and the expertise required of the observer. Thirty-one participants (11 female, 20 male; 18-37 years) were photographed from five views. Distances were computed using both camera calibration and reference object techniques from manually annotated photos. To estimate height, linear regression was applied to the distances between the top of the participants head and the floor, as well as the height of a bounding box enclosing the participant's silhouette which eliminates the need to identify the floor. To estimate MUAC, linear regression was applied to the mid-upper arm width. Estimates were computed for all view combinations and performance was compared to other photogrammetric methods from the literature-linear distance method for height, and shape models for MUAC. The mean absolute difference (MAD) between the linear regression estimates and manual measurements were smaller compared to other methods. For the optimal view combinations (smallest MAD), the technical error of measurement and coefficient of reliability also indicate the linear regression methods are more reliable. The optimal view combination was the front and side views. When estimating height by linear

  13. Anthropometric measurements of the human distal femur: a study of the adult Malay population.

    Science.gov (United States)

    Hussain, Fitdriyah; Abdul Kadir, Mohammed Rafiq; Zulkifly, Ahmad Hafiz; Sa'at, Azlin; Aziz, Azian Abd; Hossain, Golam; Kamarul, T; Syahrom, Ardiyansyah

    2013-01-01

    The distal femurs of 100 subjects (50 men, 50 women) from the Malay population aged between 19 and 38 years were scanned to measure the anterior-posterior (AP) and medial-lateral (ML) width. The mean AP values were 64.02 ± 3.38 mm and 57.33 ± 3.26 mm for men and women, respectively, and the mean ML values were 74.91 ± 3.52 mm and 64.53 ± 3.07 mm. We compared our data to that published previously for the Chinese and Indian populations. It was found that the Malay population had smaller distal femur than that of the Chinese but was larger than that of the Indian population (P < 0.05). In conclusion, although it is well established that Asians have a smaller distal femur size than that of the Western population, the variations in different Asian ethnicities may need to be considered when designing the appropriate knee implant.

  14. Anthropometric Measurements of the Human Distal Femur: A Study of the Adult Malay Population

    Directory of Open Access Journals (Sweden)

    Fitdriyah Hussain

    2013-01-01

    Full Text Available The distal femurs of 100 subjects (50 men, 50 women from the Malay population aged between 19 and 38 years were scanned to measure the anterior-posterior (AP and medial-lateral (ML width. The mean AP values were 64.02 ± 3.38 mm and 57.33 ± 3.26 mm for men and women, respectively, and the mean ML values were 74.91 ± 3.52 mm and 64.53 ± 3.07 mm. We compared our data to that published previously for the Chinese and Indian populations. It was found that the Malay population had smaller distal femur than that of the Chinese but was larger than that of the Indian population (P < 0.05. In conclusion, although it is well established that Asians have a smaller distal femur size than that of the Western population, the variations in different Asian ethnicities may need to be considered when designing the appropriate knee implant.

  15. Correlation of Insulin Resistance with Anthropometric Measures and Blood Pressure in Adolescents

    Science.gov (United States)

    de Morais, Polyana Resende Silva; Sousa, Ana Luiza Lima; Jardim, Thiago de Souza Veiga; Nascente, Flávia Miquetichuc Nogueira; Mendonça, Karla Lorena; Povoa, Thaís Inácio Rolim; Carneiro, Carolina de Souza; Ferreira, Vanessa Roriz; de Souza, Weimar Kunz Sebba Barroso; Jardim, Paulo César Brandão Veiga

    2016-01-01

    Background Blood pressure is directly related to body mass index, and individuals with increased waist circumference have higher risk of developing hypertension, insulin resistance, and other metabolic changes, since adolescence. Objective to evaluate the correlation of blood pressure with insulin resistance, waist circumference and body mass index in adolescents. Methods Cross-section study on a representative sample of adolescent students. One group of adolescents with altered blood pressure detected by casual blood pressure and/or home blood pressure monitoring (blood pressure > 90th percentile) and one group of normotensive adolescents were studied. Body mass index, waist circumference were measured, and fasting glucose and plasma insulin levels were determined, using the HOMA-IR index to identify insulin resistance. Results A total of 162 adolescents (35 with normal blood pressure and 127 with altered blood pressure) were studied; 61% (n = 99) of them were boys and the mean age was 14.9 ± 1.62 years. Thirty-eight (23.5%) adolescents had altered HOMA-IR. The group with altered blood pressure had higher values of waist circumference, body mass index and HOMA-IR (pHOMA-IR than boys (pHOMA-IR in the group with altered blood pressure (ρ = 0.394; p HOMA-IR in both groups (ρ = 0.345; p HOMA-IR was as predictor of altered blood pressure (odds ratio - OR = 2.0; p = 0.001). Conclusion There was a significant association of insulin resistance with blood pressure and the impact of insulin resistance on blood pressure since childhood. The correlation and association between markers of cardiovascular diseases was more pronounced in adolescents with altered blood pressure, suggesting that primary prevention strategies for cardiovascular risk factors should be early implemented in childhood and adolescence. PMID:27007222

  16. Ramadan major nutrient patterns are associated with anthropometric measurements and physical activity in Tehran, Iran

    Directory of Open Access Journals (Sweden)

    Mahdieh Akhoundan

    2015-05-01

    Full Text Available During Ramadan fasting quantity and quality of dietary intake may change. There was no data on nutrient patterns in Ramadan fasting. The purpose of this study was to identify Ramadan major nutrient patterns among those who fast in Tehran, Iran. 510 fasting people aged 18-65 years and BMI 18.5-40 Kg/m2 were recruited in our study by 2-stage cluster sampling method in June-July 2014. Data on the socio-demographic and physical activity level were collected by questionnaire. Usual diet during Ramadan was estimated by valid and reliable food frequency questionnaire. BMI was calculated based on measured height and weight. Three nutrient patterns derived by conducting principal component factor analysis on 30 major nutrients. Micronutrient and fiber pattern which characterized by high intake of vitamin K, total fiber, iron, manganese, magnesium, β-carotene, folate, vitamin B12, potassium and calcium was adversely associated with weight (b=-0.16, P= 0.004. High protein pattern had great loadings on protein, riboflavin, phosphorous and zinc which physical activity level was decreased by tertiles of this pattern (b=0.13, P=0.02. High carbohydrate pattern which presented high positive loadings on carbohydrate and thiamin and negative loading on total fat, poly unsaturated fatty acids and monounsaturated fatty acids was positively associated with BMI (b= 0.12, P=0.03. Adherence to different Ramadan nutrient patterns is associated with weight, BMI and physical activity level. People on high in carbohydrate may have a higher BMI and low micronutrient density diet that should be considered in Ramadan fasting nutrition educational programs.

  17. Relationship between Anthropometric Measures and Cardiovascular Risk Factors in Children and Adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Burgos, Miria Suzana [Universidade de Santa Cruz do Sul - UNISC, Santa Cruz do Sul, RS (Brazil); Programa de Pós-graduação - Mestrado em Promoção da Saúde - UNISC, Santa Cruz do Sul, RS (Brazil); Burgos, Leandro Tibiriçá; Camargo, Marcelo Dias [Grupo de Pesquisa em Cardiologia do Exercício HCPA/UFRGS, Porto Alegre, RS (Brazil); Franke, Silvia Isabel Rech; Prá, Daniel [Universidade de Santa Cruz do Sul - UNISC, Santa Cruz do Sul, RS (Brazil); Programa de Pós-graduação - Mestrado em Promoção da Saúde - UNISC, Santa Cruz do Sul, RS (Brazil); Silva, Antônio Marcos Vargas da [Universidade Federal de Santa Maria - UFSM, Santa Maria, RS (Brazil); Borges, Tássia Silvana; Todendi, Pâmela Ferreira [Universidade de Santa Cruz do Sul - UNISC, Santa Cruz do Sul, RS (Brazil); Programa de Pós-graduação - Mestrado em Promoção da Saúde - UNISC, Santa Cruz do Sul, RS (Brazil); Reckziegel, Miriam Beatris [Universidade de Santa Cruz do Sul - UNISC, Santa Cruz do Sul, RS (Brazil); Reuter, Cézane Priscila, E-mail: cpreuter@hotmail.com [Universidade de Santa Cruz do Sul - UNISC, Santa Cruz do Sul, RS (Brazil); Programa de Pós-graduação - Mestrado em Promoção da Saúde - UNISC, Santa Cruz do Sul, RS (Brazil)

    2013-10-15

    Obesity has been identified as an important risk factor in the development of cardiovascular diseases; however, other factors, combined or not with obesity, can influence cardiovascular risk and should be considered in cardiovascular risk stratification in pediatrics. To analyze the association between anthropometry measures and cardiovascular risk factors, to investigate the determinants to changes in blood pressure (BP), and to propose a prediction equation to waist circumference (WC) in children and adolescents. We evaluated 1,950 children and adolescents, aged 7 to 18 years. Visceral fat was assessed by WC and waist hip relationship, BP and body mass index (BMI). In a randomly selected subsample of these volunteers (n = 578), total cholesterol, glucose and triglycerides levels were evaluated. WC was positively correlated with BMI (r = 0.85; p < 0.001) and BP (SBP r = 0.45 and DBP = 0.37; p < 0.001). Glycaemia and triglycerides showed a weak correlation with WC (r = 0.110; p = 0.008 e r = 0.201; p < 0.001, respectively). Total cholesterol did not correlate with any of the variables. Age, BMI and WC were significant predictors on the regression models for BP (p < 0.001). We propose a WC prediction equation for children and adolescents: boys: y = 17.243 + 0.316 (height in cm); girls: y = 25.197 + 0.256 (height in cm). WC is associated with cardiovascular risk factors and presents itself as a risk factor predictor of hypertension in children and adolescents. The WC prediction equation proposed by us should be tested in future studies.

  18. Relationship between Anthropometric Measures and Cardiovascular Risk Factors in Children and Adolescents

    International Nuclear Information System (INIS)

    Burgos, Miria Suzana; Burgos, Leandro Tibiriçá; Camargo, Marcelo Dias; Franke, Silvia Isabel Rech; Prá, Daniel; Silva, Antônio Marcos Vargas da; Borges, Tássia Silvana; Todendi, Pâmela Ferreira; Reckziegel, Miriam Beatris; Reuter, Cézane Priscila

    2013-01-01

    Obesity has been identified as an important risk factor in the development of cardiovascular diseases; however, other factors, combined or not with obesity, can influence cardiovascular risk and should be considered in cardiovascular risk stratification in pediatrics. To analyze the association between anthropometry measures and cardiovascular risk factors, to investigate the determinants to changes in blood pressure (BP), and to propose a prediction equation to waist circumference (WC) in children and adolescents. We evaluated 1,950 children and adolescents, aged 7 to 18 years. Visceral fat was assessed by WC and waist hip relationship, BP and body mass index (BMI). In a randomly selected subsample of these volunteers (n = 578), total cholesterol, glucose and triglycerides levels were evaluated. WC was positively correlated with BMI (r = 0.85; p < 0.001) and BP (SBP r = 0.45 and DBP = 0.37; p < 0.001). Glycaemia and triglycerides showed a weak correlation with WC (r = 0.110; p = 0.008 e r = 0.201; p < 0.001, respectively). Total cholesterol did not correlate with any of the variables. Age, BMI and WC were significant predictors on the regression models for BP (p < 0.001). We propose a WC prediction equation for children and adolescents: boys: y = 17.243 + 0.316 (height in cm); girls: y = 25.197 + 0.256 (height in cm). WC is associated with cardiovascular risk factors and presents itself as a risk factor predictor of hypertension in children and adolescents. The WC prediction equation proposed by us should be tested in future studies

  19. The effects of 17β-estradiol plus drospirenone on anthropometric and biochemical measures of adiposity in menopausal women.

    Science.gov (United States)

    Karakus, Mesut; Gelisgen, Remise; Topcuoglu, Ata; Guralp, Onur; Topcuoglu, Deniz; Simsek, Gonul; Uludag, Seyfettin; Uzun, Hafize

    2012-11-01

    To assess whether there are changes on anthropometric and biochemical measures of adiposity in pre- and postmenopausal women and in the latter before and after 6 months treatment with 17β-estradiol plus drospirenone. Twenty postmenopausal and 20 premenopausal women were enrolled in a prospective comparative study. Postmenopausal women received 1 mg 17β-estradiol plus 2 mg drospirenone daily for 6 months. Measurements of body mass index (BMI), waist/hip ratio and plasmatic levels of insulin, glucose, high-density lipoprotein (HDL), low-density lipoprotein (LDL), triglyceride, leptin, adiponectin, orexin-A, glucagon-like peptide-1 (GLP-1) and ghrelin were performed in premenopausal (group 1) and postmenopausal women and in the latter before (group 2a) and after (group 2b) 6 months treatment with 17β-estradiol plus drospirenone. No significant changes in BMIs, insulin and glucose were observed between group 1 and 2a; and group 2a and 2b. GLP-1 levels were significantly increased in group 1 compared to group 2a (p = 0.035). Leptin levels were significantly increased (p = 0.001) and GLP-1 levels were significantly decreased (p = 0.021) in group 2b compared to group 2a. HDL was significantly decreased while LDL and triglyceride levels were significantly increased in group 2a compared to group 1. (p = 0.030, p = 0.001, p = 0.020; respectively) LDL was significantly decreased (p = 0.010) in group 2b compared to group 2a. GLP-1 had a positive correlation with orexin-A (p correlation with leptin (p = 0.008, r = -0.345). Leptin was significantly higher and GLP-1 was significantly lower in women receiving 17β-estradiol plus drospirenone treatment. GLP-1 levels were significantly lower after the menopause compared to premenopausal levels. Orexin-A and GLP-1 were positively correlated.

  20. Three-dimensional surface scanners compared with standard anthropometric measurements for head shape

    NARCIS (Netherlands)

    Beaumont, C.A.A. (Caroline A.A.); Knoops, P.G.M. (Paul G.M.); Borghi, A. (Alessandro); Jeelani, N.U.O. (N.U. Owase); M.J. Koudstaal (Maarten); S. Schievano (Silvia); D.J. Dunaway (David); Rodriguez-Florez, N. (Naiara)

    2016-01-01

    textabstractThree-dimensional (3D) surface imaging devices designed to capture and quantify craniofacial surface morphology are becoming more common in clinical environments. Such scanners overcome the limitations of two-dimensional photographs while avoiding the ionizing radiation of computed

  1. Three-dimensional surface scanners compared with standard anthropometric measurements for head shape

    NARCIS (Netherlands)

    Beaumont, C.A.A. (Caroline A.A.); Knoops, P.G.M. (Paul G.M.); Borghi, A. (Alessandro); Jeelani, N.U.O. (N.U. Owase); M.J. Koudstaal (Maarten); S. Schievano (Silvia); D.J. Dunaway (David); Rodriguez-Florez, N. (Naiara)

    2017-01-01

    textabstractThree-dimensional (3D) surface imaging devices designed to capture and quantify craniofacial surface morphology are becoming more common in clinical environments. Such scanners overcome the limitations of two-dimensional photographs while avoiding the ionizing radiation of computed

  2. Effects of ballet training of children in Turkey on foot anthropometric measurements and medial longitudinal arc development.

    Science.gov (United States)

    Ozdinc, Sevgi Anar; Turan, Fatma Nesrin

    2016-07-01

    To investigate the effects of ballet training on foot structure and the formation of the medial longitudinal arc in childhood, and the association of body mass index with structural change secondary to ballet training. This study was conducted at Öykü Ballet and Dance School and Trakya University, Edirne, Turkey, from September 2007 to November 2008, and comprised girl students who were taking ballet classes, and a group of those who were not taking such who acted as the controls. Static footprints of both feet of all participants were taken with an ink paedogram. Parameters evaluated from footprints included foot length, metatarsal width, heel width and medial longitudinal arch. The relationship between the parameters, the ballet starting age, training duration and body mass index was investigated. Of the 67 participants, there were 36(53.7%) in the experimental group and 31(48.3%) in the control group. The difference between age, height, weight and body mass index between the two groups was insignificant (p>0.05). The average ballet starting age was 6.47±1.55 years and duration was 4.36±2.002 years. Positive correlations were found between body mass index and foot length, metatarsal width, heel width, medial longitudinal arch contact width and halluxvalgus angle; between ballet starting age and metatarsal width, heel width; between duration of training and foot length, metatarsal width and hallux valgus angle (p?0.05 each). Evidence supporting the education in children on foot anthropometric measurements and medial longitudinal arc development could not be found.

  3. Caffeine Intake During Pregnancy in Different Intrauterine Environments and its Association with Infant Anthropometric Measurements at 3 and 6 Months of Age.

    Science.gov (United States)

    de Medeiros, Thamíris Santos; Bernardi, Juliana Rombaldi; de Brito, Mariana Lopes; Bosa, Vera Lucia; Goldani, Marcelo Zubaran; da Silva, Clécio Homrich

    2017-06-01

    Objective To investigate the association between maternal caffeine intake during pregnancy and infant anthropometric measurements at age 3 and 6 months. Methods Longitudinal observational study of mother-child pairs stratified into five groups: diabetic women (DM), hypertensive women (HYP), smoking mothers (SMO), mothers of infants small for gestational age (SGA), and controls (CTL). Pairs were recruited from three public hospitals in Porto Alegre, Brazil, from 2011 to 2015, using a convenience sampling strategy. The Food Frequency Questionnaire (FFQ) was administered on postpartum day 7 to evaluate maternal caffeine intake during pregnancy. The anthropometric measurements of interest (weight, length, and skinfold thickness) were assessed at birth and at age 3 and 6 months. Linear regression was used to analyze the interaction between caffeine intake and skinfold thickness. Results Overall, 272 mother-child pairs were investigated (41 DM, 26 HYP, 68 SMO, 25 SGA, and 112 CTL). There were no differences in anthropometric measurements between infants born to mothers who had and had not consumed caffeine during pregnancy (P > 0.05). Children of mothers in the DM group had the highest adjusted average skinfold thicknesses at 3 months. An interaction between maternal caffeine intake during pregnancy and the sum of skinfolds at age 3 months was found in the DM and CTL groups (P caffeine intake influenced infants skinfold thickness measurements at 3 months of age. This parameter was reduced in infants born to mothers with DM and increased in those born to healthy control mothers.

  4. The Effects of Cognitive-Behavioral Motivation for Health Improvement on Anthropometric Measurements in High Risk Individuals

    Science.gov (United States)

    2012-03-22

    bill and reduce absenteeism and presenteeism in the work place implementation of a cognitive-behavioral motivation treatment should be one of the...THE EFFECTS OF COGNITIVE-BEHAVIORAL MOTIVATION FOR HEALTH IMPROVEMENT ON ANTHROPOMETRIC...Government and is not subject to copyright protection in the United States. AFIT/GCA/ENV/12-M02 THE EFFECTS OF COGNITIVE-BEHAVIORAL MOTIVATION

  5. Comparison of the anthropometric measurements and health risks in people with normal weight according to the body mass index-for-age charts

    Directory of Open Access Journals (Sweden)

    Ignatio R. Haryono

    2009-03-01

    Full Text Available Aim Body mass index (BMI at 5th-84th percentiles according to the BMI-for-age charts from Center for Diseases Control and Prevention (CDC is considered as normal BMI for children and adolescents. However, Guo et al found that BMI at 75th-84th percentiles already had a possibility to be adult overweight and obese. This study aimed to determine anthropometric measurements, laboratory findings, and health risk differences to find an ideal BMI group according to the BMI charts.Methods Normal BMI according to adult classification from the World Health Organization (BMI at 18.5-24.9 is used as a reference group.Results & Conclusion Our study showed BMI value at 50th-74th percentiles in boys and at 75th-84th percentiles in girls had higher anthropometric measurements and laboratory findings than the reference group. However, the health risks of those BMI percentiles did not significant different compared with the reference group. (Med J Indones 2009; 18: 41-7Keywords: normoweight, adolescent, BMI-for-age charts, anthropometric measurements, health risks

  6. Standard Model measurements with the ATLAS detector

    Directory of Open Access Journals (Sweden)

    Hassani Samira

    2015-01-01

    Full Text Available Various Standard Model measurements have been performed in proton-proton collisions at a centre-of-mass energy of √s = 7 and 8 TeV using the ATLAS detector at the Large Hadron Collider. A review of a selection of the latest results of electroweak measurements, W/Z production in association with jets, jet physics and soft QCD is given. Measurements are in general found to be well described by the Standard Model predictions.

  7. Age and sex-specific associations of anthropometric measures of adiposity with blood pressure and hypertension in India: a cross-sectional study.

    Science.gov (United States)

    Taing, Kevin Y; Farkouh, Michael E; Moineddin, Rahim; Tu, Jack V; Jha, Prabhat

    2016-12-01

    A determinant of blood pressure is adiposity; however, there are uncertainties surrounding whether general or central adiposity is the more important determinant of blood pressure. Further, inconsistent results exist for the relationships of anthropometric measures with blood pressure and hypertension, and whether these relationships differ substantially by age and sex is unclear. We aimed to elucidate the associations of anthropometric measures of general and central adiposity with blood pressure and hypertension, and determine the effect of age and sex on these relationships. We used cross-sectional data from the Centre for Global Health Research health check-up survey conducted during 2006-2007 of the general population in India (n = 7 601; age 18-59 years). We examined the associations of anthropometric measures (body mass index, waist circumference, hip circumference, waist-hip ratio, waist-height ratio) with blood pressure components (systolic pressure, diastolic pressure, pulse pressure, mean arterial pressure, mid-blood pressure) and hypertension within four (18-29 years, 30-39 years, 40-49 years, 50-59 years) age groups, by sex. We adjusted all analyses for education and location, with further adjustments, variously, for either a measure of central (waist circumference) or general (body mass index) adiposity. On average, every 5 kg/m 2 greater body mass index or 10 cm wider waist circumference was associated with a 5 and 4 mmHg higher systolic blood pressure, respectively. When considered separately, each anthropometric measure was strongly and positively associated with most blood pressure components in all age groups, and for both sexes. However, with few exceptions, when considered jointly (body mass index adjusted for waist circumference), the associations of body mass index with blood pressure components and hypertension were greatly diminished for both sexes, and particularly in the ≥30 years age groups. By contrast, further adjustment

  8. Anthropometric comparison of Anthropometric Test Device (ATD ...

    African Journals Online (AJOL)

    Anthropometric test device (ATD) is surrogate used in automotive crash testing. Female ATDs used worldwide in the evaluation of vehicle safety performance was produced based on anthropometry of U.S. population. This work is aimed at assessing the difference between the anthropometric dimensions of Nigerian female ...

  9. Russian standards for dimensional measurements for nanotechnologies

    Science.gov (United States)

    Gavrilenko, V. P.; Filippov, M. N.; Novikov, Yu. A.; Rakov, A. V.; Todua, P. A.

    2009-05-01

    In order to provide the uniformity of measurements at the nanoscale, seven national standards have been developed in the Russian Federation. Of these seven standards, three standards specify the procedures of fabrication and certification of linear measures with the linewidth lying in the nanometer range. The other four standards specify the procedures of verification and calibration of customer's atomic force microscopes and scanning electron microscopes, intended to perform measurements of linear dimensions of relief nanostructures. For an atomic force microscope, the following four parameters can be deduced: scale factor for the video signal, effective radius of the cantilever tip, scale factor for the vertical axis of the microscope, relative deflection of the microscope's Z-scanner from the orthogonality to the plane of a sample surface. For a scanning electron microscope, the following two parameters can be deduced: scale factor for the video signal and the effective diameter of the electron beam. The standards came into force in 2008.

  10. Breakfast eating pattern and its association with dietary quality indices and anthropometric measurements in young women in Isfahan.

    Science.gov (United States)

    Azadbakht, Leila; Haghighatdoost, Fahimeh; Feizi, Awat; Esmaillzadeh, Ahmad

    2013-02-01

    To assess the association between consuming or skipping breakfast and dietary quality indices such as the Healthy Eating Index (HEI), the Dietary Diversity Score (DDS), diversity scores of different food groups, and anthropometric measurements in young Isfahanian women. Women 18 to 28 y old were selected randomly from among university students (n = 411) in Isfahan, Iran. A validated semiquantitative questionnaire was used to assess dietary intake. Five food groups of the Food Guide Pyramid were considered for calculating the DDS and diversity score of the food groups. Subjects were categorized based on consuming or skipping breakfast. The HEI was calculated based on 10 components including the five food groups, different fat and sodium intakes, and the DDS. Breakfast consumers versus skippers had higher scores for the HEI (66 ± 13 versus 47 ± 13, P = 0.001), the DDS (6.8 ± 1.2 versus 4.9 ± 0.7, P = 0.001), and the DDSs for fruits (1.3 ± 0.2 versus 0.9 ± 0.1, P = 0.001), vegetables (1.6 ± 0.2 versus 1.2 ± 0.1, P = 0.001), and whole grains (1.3 ± 0.2 versus 0.9 ± 0.1, P = 0.001). Also, eating breakfast was associated with lower values for dietary energy density (0.96 ± 0.25 versus 1.04 ± 0.40, P = 0.01), the body mass index (20.0 ± 1.8 versus 23.3 ± 2.7, P = 0.001), and waist circumference (69.2 ± 7.6 versus 72.5 ± 8.7, P = 0.001). There was a higher prevalence of breakfast consumers in the third tertiles of the HEI and DDS. However, there was a smaller percentage of breakfast consumers in the third tertiles of the body mass index and waist circumference. Breakfast consumption was associated with higher scores of the dietary quality indices and lower values for the body mass index and waist circumference in young Isfahanian women. Further studies should be performed to determine the relation between the kind of breakfast consumed and the dietary quality indices. Copyright © 2013. Published by Elsevier Inc.

  11. Facial Anthropometric Norms among Kosovo - Albanian Adults.

    Science.gov (United States)

    Staka, Gloria; Asllani-Hoxha, Flurije; Bimbashi, Venera

    2017-09-01

    The development of an anthropometric craniofacial database is a necessary multidisciplinary proposal. The aim of this study was to establish facial anthropometric norms and to investigate into sexual dimorphism in facial variables among Kosovo Albanian adults. The sample included 204 students of Dental School, Faculty of Medicine, University of Pristina. Using direct anthropometry, a series of 8 standard facial measurements was taken on each subject with digital caliper with an accuracy of 0.01 mm (Boss, Hamburg-Germany). The normative data and percentile rankings were calculated. Gender differences in facial variables were analyzed using t- test for independent samples (p0.05).The highest index of sexual dimorphism (ISD) was found for the lower facial height 1.120, for which the highest percentage of sexual dimorphism, 12.01%., was also found. The lowest ISD was found for intercanthal width, 1.022, accompanied with the lowest percentage of sexual dimorphism, 2.23%. The obtained results have established the facial anthropometric norms among Kosovo Albanian adults. Sexual dimorphism has been confirmed for each facial measurement.

  12. Facial Anthropometric Norms among Kosovo - Albanian Adults

    Directory of Open Access Journals (Sweden)

    Gloria Staka

    2017-01-01

    Full Text Available The development of an anthropometric craniofacial database is a necessary multidisciplinary proposal. Aim: The aim of this study was to establish facial anthropometric norms and to investigate into sexual dimorphism in facial variables among Kosovo Albanian adults. Materials and Methods: The sample included 204 students of Dental School, Faculty of Medicine, University of Pristina. Using direct anthropometry, a series of 8 standard facial measurements was taken on each subject with digital caliper with an accuracy of 0.01 mm (Boss, Hamburg-Germany. The normative data and percentile rankings were calculated. Gender differences in facial variables were analyzed using t- test for independent samples (p0.05.The highest index of sexual dimorphism (ISD was found for the lower facial height 1.120, for which the highest percentage of sexual dimorphism, 12.01%., was also found. The lowest ISD was found for intercanthal width, 1.022, accompanied with the lowest percentage of sexual dimorphism, 2.23%. Conclusion: The obtained results have established the facial anthropometric norms among Kosovo Albanian adults. Sexual dimorphism has been confirmed for each facial measurement.

  13. The 5th national survey on the physical growth and development of children in the nine cities of China: Anthropometric measurements of Chinese children under 7 years in 2015.

    Science.gov (United States)

    Zhang, Ya-Qin; Li, Hui; Wu, Hua-Hong; Zong, Xin-Nan; Zhu, Zong-Han; Pan, Ying; Li, Jia; Zheng, Xing-Rong; Wei, Mei; Tong, Mei-Ling; Zhou, Ai-Fen; Hu, Yan; Chen, Wei; Zhu, Ke; Yu, Yang

    2017-07-01

    To describe the physical growth of healthy children under 7 years in China based on the latest national survey and provide more data for revising growth reference and monitoring the impact of social development on children's health and growth. In the cross-sectional survey, 161,774 healthy children under 7 years were selected by multistage stratified cluster sampling method in nine cities of China. According to the geographical location, the nine cities were divided into northern, central and southern regions, and each city included urban and suburban areas. Anthropometric measurements were obtained on the spots and other related information was collected with questionnaires. There were slight urban-suburban difference and obvious regional difference in anthropometric measurements in China. Comparison with the 4th NSPGDC in 2005, measurements increased 0.1-1.1 kg in weight, 0.5-1.8 cm in height in urban areas (except children under 3 years) and 0.1-2.5 kg in weight, 0.2-3.8 cm in height in suburban areas. The urban-suburban difference of those measurements became smaller than 10 years ago, but their regional difference persistently exist. Chinese children were 0.36 SD in weight, 0.43 SD in height in urban areas and 0.30 SD in weight, 0.30 SD in height in suburban areas higher than WHO standards. Physical growth of children under 7 years old was undergoing a slowly positive secular trend during the latest decade in more economically developed regions of China. Urban-suburban difference of those measurements became smaller, while their regional difference persistently exist. Chinese healthy children under 7 years in nine cities was taller and heavier than WHO standards. © 2017 Wiley Periodicals, Inc.

  14. Breakfast and Breakfast Cereal Choice and Its Impact on Nutrient and Sugar Intakes and Anthropometric Measures among a Nationally Representative Sample of Australian Children and Adolescents

    Directory of Open Access Journals (Sweden)

    Flavia Fayet-Moore

    2017-09-01

    Full Text Available There is limited evidence in Australia that compares the nutritional impact of a breakfast cereal breakfast to a non-cereal breakfast, and includes the type of cereal. This study investigated the impact of breakfast choice and the total sugar content of breakfast cereal on nutrient intakes and anthropometric measures among Australian children and adolescents. Data from 2 to 18-year-old in the 2011–2012 National Nutrition and Physical Activity Survey were used (n = 2821. Participants were classified as breakfast cereal consumers (minimally pre-sweetened (MPS or pre-sweetened (PS, non-cereal breakfast consumers, or breakfast skippers. Foods consumed for breakfast, foods added to the cereal bowl, and the impact of breakfast choice on daily nutrient intakes and anthropometric measures were determined. Although only 9% of children skipped breakfast, 61% of skippers were aged 14–18 years. Among breakfast consumers, 49% had breakfast cereal, and 62% of these exclusively consumed MPS cereal. Breakfast skippers had a higher saturated fat intake than breakfast cereal consumers, and lower intakes of dietary fibre and most micronutrients (p < 0.001. Compared with non-cereal breakfast consumers, breakfast cereal consumers had additional free sugars intake, lower sodium, and higher total sugars, carbohydrate, dietary fibre, and almost all other micronutrients (p < 0.001. The only difference in nutrient intakes between MPS and PS cereal consumers was higher folate among PS consumers. No associations between anthropometric measures and breakfast or breakfast cereal choice were found. The highest prevalence of breakfast skipping was among 14–18-year old. Breakfast cereal consumers had higher intakes of dietary fibre and most micronutrients compared with non-cereal breakfast consumers and skippers, and almost no differences were found between MPS and PS cereal consumers.

  15. Breakfast and Breakfast Cereal Choice and Its Impact on Nutrient and Sugar Intakes and Anthropometric Measures among a Nationally Representative Sample of Australian Children and Adolescents.

    Science.gov (United States)

    Fayet-Moore, Flavia; McConnell, Andrew; Tuck, Kate; Petocz, Peter

    2017-09-21

    There is limited evidence in Australia that compares the nutritional impact of a breakfast cereal breakfast to a non-cereal breakfast, and includes the type of cereal. This study investigated the impact of breakfast choice and the total sugar content of breakfast cereal on nutrient intakes and anthropometric measures among Australian children and adolescents. Data from 2 to 18-year-old in the 2011-2012 National Nutrition and Physical Activity Survey were used ( n = 2821). Participants were classified as breakfast cereal consumers (minimally pre-sweetened (MPS) or pre-sweetened (PS)), non-cereal breakfast consumers, or breakfast skippers. Foods consumed for breakfast, foods added to the cereal bowl, and the impact of breakfast choice on daily nutrient intakes and anthropometric measures were determined. Although only 9% of children skipped breakfast, 61% of skippers were aged 14-18 years. Among breakfast consumers, 49% had breakfast cereal, and 62% of these exclusively consumed MPS cereal. Breakfast skippers had a higher saturated fat intake than breakfast cereal consumers, and lower intakes of dietary fibre and most micronutrients ( p < 0.001). Compared with non-cereal breakfast consumers, breakfast cereal consumers had additional free sugars intake, lower sodium, and higher total sugars, carbohydrate, dietary fibre, and almost all other micronutrients ( p < 0.001). The only difference in nutrient intakes between MPS and PS cereal consumers was higher folate among PS consumers. No associations between anthropometric measures and breakfast or breakfast cereal choice were found. The highest prevalence of breakfast skipping was among 14-18-year old. Breakfast cereal consumers had higher intakes of dietary fibre and most micronutrients compared with non-cereal breakfast consumers and skippers, and almost no differences were found between MPS and PS cereal consumers.

  16. Pericardial and thoracic peri-aortic adipose tissues contribute to systemic inflammation and calcified coronary atherosclerosis independent of body fat composition, anthropometric measures and traditional cardiovascular risks

    International Nuclear Information System (INIS)

    Yun, Chun-Ho; Lin, Tin-Yu; Wu, Yih-Jer; Liu, Chuan-Chuan; Kuo, Jen-Yuan; Yeh, Hung-I.; Yang, Fei-Shih; Chen, Su-Chiu; Hou, Charles Jia-Yin; Bezerra, Hiram G.; Hung, Chung-Lieh; Cury, Ricardo C.

    2012-01-01

    Background: Coronary atherosclerosis has traditionally been proposed to be associated with several cardiovascular risk factors and anthropometric measures. However, clinical data regarding the independent value of visceral adipose tissue in addition to such traditional predictors remains obscure. Materials and methods: We subsequently studied 719 subjects (age: 48.1 ± 8.3 years, 25% females) who underwent multidetector computed tomography (MDCT) for coronary calcium score (CCS) quantification. Baseline demographic data and anthropometric measures were taken with simultaneous body fat composition estimated. Visceral adipose tissue of pericardial and thoracic peri-aortic fat was quantified by MDCT using TeraRecon Aquarius workstation (San Mateo, CA). Traditional cardiovascular risk stratification was calculated by metabolic (NCEP ATP III) and Framingham (FRS) scores and high-sensitivity CRP (Hs-CRP) was taken to represent systemic inflammation. The independent value of visceral adipose tissue to systemic inflammation and CCS was assessed by utilizing multivariable regression analysis. Results: Of all subjects enrolled in this study, the mean values for pericardial and peri-aortic adipose tissue were 74.23 ± 27.51 and 7.23 ± 3.69 ml, respectively. Higher visceral fat quartile groups were associated with graded increase of risks for cardiovascular diseases. Both adipose burdens strongly correlated with anthropometric measures including waist circumference, body weight and body mass index (all p < 0.001). In addition, both visceral amount correlates well with ATP and FRS scores, all lipid profiles and systemic inflammation marker in terms of Hs-CRP (all p < 0.001). After adjustment for baseline variables, both visceral fat were independently related to Hs-CRP levels (all p < 0.05), but only pericardial fat exerted independent role in coronary calcium deposit. Conclusion: Both visceral adipose tissues strongly correlated with systemic inflammation beyond traditional

  17. The Agency's Safety Standards and Measures

    International Nuclear Information System (INIS)

    1976-04-01

    The Agency's Health and Safety Measures were first, approved by the Board of Governors on 31 March 1960 in implementation of Articles III.A.6 and XII of the Statute of the Agency. On the basis of the experience gained from applying those measures to projects carried out by Members under agreements concluded with the Agency, the Agency's Health and Safety Measures were revised in 1975 and approved by the Board of Governors on 25 February 1976. The Agency's Safety Standards and Measures as revised are reproduced in this document for the information of all Members

  18. Comparison of Giant-Slalom Results, Selected Anthropometric Measurements and Physical Fitness Tests between Female and Male Competitors in Under 14 Category

    Directory of Open Access Journals (Sweden)

    Stojan Puhalj

    2016-04-01

    Full Text Available The purpose of the research was to determine whether there are any differences in selected anthropometric measurements, physical fitness tests and the average times achieved in three competitions in giant slalom between female and male alpine skiing competitors in category U14. The research was conducted on a sample of 40 categorized competitors, 20 boys M = 12.5; SD = 0.513 and 20 girls M = 12.55; SD = 0.510. Gender differences in selected anthropometric measurements (volume of the left knee, body mass index (BMI, and percentage of body fat, selected physical fitness tests (ten jumps on both legs, running eights, and test of stability, and ski result were assessed using t-test for independent samples. In order to assess ski result, average time from tree giant-slalom runs was used. Statistical significance was set at the α level of 0.05. The results showed that there were statistically significant differences (p <0.05 only in the percentage of body fat. We established that the levels of selected physical fitness tests in the female and male competitors aged under 14 years in the season 2013/14 are equal. It should also be noted that the groups do not differ in most of the selected anthropometric dimensions. It is therefore not surprising that the level of skiing skills, gained by female and male competitors in categoriesU14, is equal. The research results demonstrated the possibility of uniform and related training procedures and competitions in alpine skiing for boys and girls aged under 14 years.

  19. Anthropometric predictive equations for estimating body composition

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Salamat

    2015-01-01

    Conclusions: Combinations of anthropometric measurements predict whole-body lean mass and trunk fat mass better than any of these single anthropometric indices. Therefore, the findings of the present study may be used to verify the results in patients with various diseases or diets.

  20. Sex Differences In Anthropometric Characteristics Of Nigerian ...

    African Journals Online (AJOL)

    The aim of this study was to assess the anthropometric and body composition profiles of Nigerian school children. A cross-sectional study was carried out involving 1036 girls and 979 boys aged 9-12 years. Anthropometric measurements, including body mass, stature, triceps, subscapular and medial calf skinfold thickness, ...

  1. A comparison between handgrip strength, upper limb fat free mass by segmental bioelectrical impedance analysis (SBIA) and anthropometric measurements in young males

    Science.gov (United States)

    Gonzalez-Correa, C. H.; Caicedo-Eraso, J. C.; Varon-Serna, D. R.

    2013-04-01

    The mechanical function and size of a muscle may be closely linked. Handgrip strength (HGS) has been used as a predictor of functional performing. Anthropometric measurements have been made to estimate arm muscle area (AMA) and physical muscle mass volume of upper limb (ULMMV). Electrical volume estimation is possible by segmental BIA measurements of fat free mass (SBIA-FFM), mainly muscle-mass. Relationship among these variables is not well established. We aimed to determine if physical and electrical muscle mass estimations relate to each other and to what extent HGS is to be related to its size measured by both methods in normal or overweight young males. Regression analysis was used to determine association between these variables. Subjects showed a decreased HGS (65.5%), FFM, (85.5%) and AMA (74.5%). It was found an acceptable association between SBIA-FFM and AMA (r2 = 0.60) and poorer between physical and electrical volume (r2 = 0.55). However, a paired Student t-test and Bland and Altman plot showed that physical and electrical models were not interchangeable (pt<0.0001). HGS showed a very weak association with anthropometric (r2 = 0.07) and electrical (r2 = 0.192) ULMMV showing that muscle mass quantity does not mean muscle strength. Other factors influencing HGS like physical training or nutrition require more research.

  2. Effects of prenatal music stimulation on fetal cardiac state, newborn anthropometric measurements and vital signs of pregnant women: A randomized controlled trial.

    Science.gov (United States)

    García González, J; Ventura Miranda, M I; Manchon García, F; Pallarés Ruiz, T I; Marin Gascón, M L; Requena Mullor, M; Alarcón Rodriguez, R; Parron Carreño, T

    2017-05-01

    Music has been used for medicinal purposes throughout history due to its variety of physiological, psychological and social effects. To identify the effects of prenatal music stimulation on the vital signs of pregnant women at full term, on the modification of fetal cardiac status during a fetal monitoring cardiotocograph, and on anthropometric measurements of newborns taken after birth. A randomized controlled trial was implemented. The four hundred and nine pregnant women coming for routine prenatal care were randomized in the third trimester to receive either music (n = 204) or no music (n = 205) during a fetal monitoring cardiotocograph. All of the pregnant women were evaluated by measuring fetal cardiac status (basal fetal heart rate and fetal reactivity), vital signs before and after a fetal monitoring cardiotocograph (maternal heart rate and systolic and diastolic blood pressure), and anthropometric measurements of the newborns were taken after birth (weight, height, head circumference and chest circumference). The strip charts showed a significantly increased basal fetal heart rate and higher fetal reactivity, with accelerations of fetal heart rate in pregnant women with music stimulation. After the fetal monitoring cardiotocograph, a statistically significant decrease in systolic blood pressure, diastolic blood pressure and heart rate in women receiving music stimulation was observed. Music can be used as a tool which improves the vital signs of pregnant women during the third trimester, and can influence the fetus by increasing fetal heart rate and fetal reactivity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Medidas faciais antropométricas de adultos segundo tipo facial e sexo Adult facial anthropometric measurements according to facial type and gender

    Directory of Open Access Journals (Sweden)

    Rossana Ribeiro Ramires

    2011-04-01

    Full Text Available OBJETIVO: descrever medidas antropométricas faciais de adultos, segundo tipo facial e sexo. MÉTODOS: participaram 105 adultos leucodermas, 34 (32,4% homens e 71 (67,6% mulheres, com idades entre 20 e 40 anos, de uma clínica particular de ortodontia de Belo Horizonte, Minas Gerais. Foram comparados os achados da análise cefalométrica para determinação do tipo de face com sete medidas antropométricas faciais diretas: altura facial anterior- násio ao mentoniano; distância bizigomática- zigomático esquerdo ao direito; altura do terço facial inferior- subnasal ao mentoniano; altura da face média- násio ao estômio; altura do queixo- supramentoniano ao mentoniano; altura da face inferior- estômio ao mentoniano; e altura facial posterior- condílio ao gônio. RESULTADOS: para o sexo masculino, os tipos faciais classificados por meio da cefalometria apresentaram diferenças estatisticamente significantes para os valores médios das medidas antropométricas: altura facial anterior, altura do terço facial inferior, altura da face média e altura da face inferior. Para o sexo feminino, diferenças estatisticamente significantes foram encontradas nas medidas: altura facial anterior, altura do terço facial inferior, altura da face média, altura da face inferior e altura facial posterior. CONCLUSÃO: houve dimorfismo sexual para todas as medidas antropométricas obtidas, as quais tiveram valores médios maiores para o sexo masculino quando comparados ao feminino. Os tipos faciais classificados por meio da cefalometria apresentaram diferenças estatisticamente significantes para quatro medidas antropométricas do sexo masculino e cinco do feminino.PURPOSE: to describe anthropometric measurements in adults according to facial type and gender. METHODS: 105 Caucasian adults took part, 34 male (32.4% and 71 female (67.6% with ages between 20 and 40-year old, in a private orthodontic clinic in Belo Horizonte, Minas Gerais, Brazil. The findings

  4. The CODATwins Project: The Cohort Description of Collaborative Project of Development of Anthropometrical Measures in Twins to Study Macro-Environmental Variation in Genetic and Environmental Effects on Anthropometric Traits

    NARCIS (Netherlands)

    Silventoinen, K.; Jelenkovic, A.; Sund, R.; Honda, C.; Aaltonen, S.; Yokoyama, Y.; Tarnoki, A.D.; Tarnoki, D.L.; Ning, F.; Ji, F.; Pang, Z.; Ordonana, J.R.; Sanchez-Romera, J.F.; Colodro-Conde, L.; Burt, S.A.; Klump, K.L.; Medland, S.E.; Montgomery, G.W.; Kandler, C.; McAdams, T.A.; Eley, T.C.; Gregory, A.M.; Saudino, K.J.; Dubois, L.; Boivin, M.; Haworth, C.M.A.; Plomin, R.; Oncel, S.Y.; Aliev, F.; Stazi, M.A.; Fagnani, C.; D'Ippolito, C.; Craig, J.M.; Saffery, R.; Siribaddana, S.H.; Hotopf, M.; Sumathipala, A.; Spector, T.; Mangino, M.; Lachance, G.; Gatz, M.; Butler, D.A.; Bayasgalan, G.; Narandalai, D.; Freitas, D.L.; Maia, J.A.; Harden, K.P.; Tucker-Drob, E.M.; Christensen, K.; Skytthe, A.; Kyvik, K.O.; Hong, C.; Chong, Y.; Derom, C.A.; Vlietinck, R.F.; Loos, R.J.F.; Cozen, W.; Hwang, A.E.; Mack, T.M.; He, M.; Ding, X.; Chang, B.; Silberg, J.L.; Eaves, L.J.; Maes, H.H.; Cutler, T.L.; Hopper, J.L.; Aujard, K.; Magnusson, P.K.E.; Pedersen, N.L.; Aslan, A.K.D.; Song, Y.; Yang, S.; Lee, K; Baker, L.A.; Tuvblad, C.; Bjerregaard-Andersen, M.; Beck-Nielsen, H.; Sodemann, M.; Heikkila, K.; Tan, Q.; Zhang, D.; Swan, G.E.; Krasnow, R.; Jang, K.L.; Knafo-Noam, A.; Mankuta, D.; Abramson, L.; Lichtenstein, P.; Krueger, R.F.; McGue, M.; Pahlen, S.; Tynelius, P.; Duncan, G.E.; Buchwald, D.; Corley, R.P.; Huibregtse, B.M.; Nelson, T.L.; Whitfield, K.E.; Franz, C.E.; Kremen, W.S.; Lyons, M.J.; Ooki, S.; Brandt, I.; Nilsen, T.S.; Inui, F.; Watanabe, M.; Bartels, M.; van Beijsterveldt, T.C.E.M.; Wardle, J.; Llewellyn, C.H.; Fisher, A.; Rebato, E.; Martin, N.G.; Iwatani, Y.; Hayakawa, K.; Rasmussen, F.; Sung, J.; Harris, J.R.; Willemsen, G.; Busjahn, A.; Goldberg, J.H.; Boomsma, D.I.; Hur, Y.; Sorensen, T.I.A.; Kaprio, J.

    2015-01-01

    For over 100 years, the genetics of human anthropometric traits has attracted scientific interest. In particular, height and body mass index (BMI, calculated as kg/m2) have been under intensive genetic research. However, it is still largely unknown whether and how heritability estimates vary between

  5. Adductor policis muscle: a new anthropometric parameter

    Directory of Open Access Journals (Sweden)

    Lameu Edson Braga

    2004-01-01

    Full Text Available PURPOSE: To measure the thickness of adductor pollicis muscle in healthy adults. This measurement will be used as a nutritional anthropometric parameter in further studies. SUBJECTS AND METHOD: Four hundred and twenty-one healthy adults were studied, 209 men and 212 women, with ages ranging from 18 to 87 years, living in Rio de Janeiro. The adductor pollicis muscle was also studied in the human anatomy lab as well as in normal healthy volunteers using CAT scans and nuclear magnetic resonance imaging to ensure that only the adductor pollicis was included in measurement of muscle thickness with a Lange caliper. To standardize the measurement, the methodology was detailed, with subjects sitting with the dominant hand dangling over the homolateral thigh and the elbow bent at approximately a 90° angle. The Lange caliper was applied at a pressure of 10 g/mm², pinching the adductor pollicis muscle at the vertex of an imaginary angle between the thumb and the index finger. The average of 3 consecutive measurements was considered to be the muscle thickness. RESULTS: This study provides the first estimates of adductor pollicis thickness in normal healthy subjects as an anthropometric parameter. The normal values in the dominant hand for men were 12.5 ± 2.8 mm (mean ± SD, median 12 mm, and for women were 10.5 ± 2.3 mm, median 10 mm.

  6. Effect of physical activity intervention based on a pedometer on physical activity level and anthropometric measures after childbirth: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Maturi Masumeh S

    2011-12-01

    Full Text Available Abstract Background Pregnancy and childbirth are associated with weight gain in women, and retention of weight gained during pregnancy can lead to obesity in later life. Diet and physical activity are factors that can influence the loss of retained pregnancy weight after birth. Exercise guidelines exist for pregnancy, but recommendations for exercise after childbirth are virtually nonexistent. The aim of this study was to evaluate the effect of physical activity intervention based on pedometer on physical activity level and anthropometric measures of women after childbirth. Methods We conducted a randomized controlled trial in which 66 women who had given birth 6 weeks to 6 months prior were randomly assigned to receive either a 12 week tailored program encouraging increased walking using a pedometer (intervention group, n = 32 or routine postpartum care (control group, n = 34. During the 12-week study period, each woman in the intervention group wore a pedometer and recorded her daily step count. The women were advised to increase their steps by 500 per week until they achieved the first target of 5000 steps per day and then continued to increase it to minimum of 10,000 steps per day by the end of 12th week. Assessed outcomes included anthropometric measures, physical activity level, and energy expenditure per week. Data were analyzed using the paired t-test, independent t-test, Mann-Whitney, chi-square, Wilcoxon, covariance analysis, and the general linear model repeated measures procedure as appropriate. Results After 12 weeks, women in the intervention group had significantly increased their physical activity and energy expenditure per week (4394 vs. 1651 calorie, p P = 0.001, Body Mass Index (P = 0.001, waist circumference (P = 0.001, hip circumference (P = 0.032 and waist-hip ratio (P = 0.02 were presented after the intervention. The intervention group significantly increased their mean daily step count over the study period (from 3249

  7. Validity of anthropometric measurements to assess body composition, including muscle mass, in 3-year-old children from the SKOT cohort

    DEFF Research Database (Denmark)

    Jensen, Signe Marie; Mølgaard, Christian; Ejlerskov, Katrine Tschentscher

    2015-01-01

    Nutritional status of children is commonly assessed by anthropometry both in under and overnutrition. The link between anthropometry and body fat, the body compartment most affected by overnutrition, is well known, but the link with muscle mass, the body compartment most depleted in undernutrition...... to estimate muscle mass. Overall, anthropometric measures were more effective to measure absolute size of fat, lean and muscle mass than their relative sizes. Proportion of the variance explained by anthropometry was 79% for lean mass, 76% for fat mass and 74% for muscle mass. For fat mass and lean mass......, which included only mid-upper arm circumference and subscapular skinfold. The power of height in the weight-to-height ratio to determine fat mass proportion was 1.71 with a 95% confidence interval (0.83-2.60) including the value of 2 used in body mass index (BMI). Limitations of anthropometry to assess...

  8. Quantitative Anthropometric Measures of Facial Appearance of Healthy Hispanic/Latino White Children: Establishing Reference Data for Care of Cleft Lip With or Without Cleft Palate

    Science.gov (United States)

    Lee, Juhun; Ku, Brian; Combs, Patrick D.; Da Silveira, Adriana. C.; Markey, Mia K.

    2017-06-01

    Cleft lip with or without cleft palate (CL ± P) is one of the most common congenital facial deformities worldwide. To minimize negative social consequences of CL ± P, reconstructive surgery is conducted to modify the face to a more normal appearance. Each race/ethnic group requires its own facial norm data, yet there are no existing facial norm data for Hispanic/Latino White children. The objective of this paper is to identify measures of facial appearance relevant for planning reconstructive surgery for CL ± P of Hispanic/Latino White children. Quantitative analysis was conducted on 3D facial images of 82 (41 girls, 41 boys) healthy Hispanic/Latino White children whose ages ranged from 7 to 12 years. Twenty-eight facial anthropometric features related to CL ± P (mainly in the nasal and mouth area) were measured from 3D facial images. In addition, facial aesthetic ratings were obtained from 16 non-clinical observers for the same 3D facial images using a 7-point Likert scale. Pearson correlation analysis was conducted to find features that were correlated with the panel ratings of observers. Boys with a longer face and nose, or thicker upper and lower lips are considered more attractive than others while girls with a less curved middle face contour are considered more attractive than others. Associated facial landmarks for these features are primary focus areas for reconstructive surgery for CL ± P. This study identified anthropometric measures of facial features of Hispanic/Latino White children that are pertinent to CL ± P and which correlate with the panel attractiveness ratings.

  9. Standardized Testing of Phasor Measurement Units

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Kenneth E.; Faris, Anthony J.; Hauer, John F.

    2006-05-31

    This paper describes a set of tests used to determine Phasor Measurement Unit (PMU) measurement characteristics under steady state and dynamic conditions. The methodology is repeatable, comparable among test facilities, and can be performed at any facility with commonly available relay and standard test equipment. The methodology is based upon using test signals that are mathematically generated from a signal model and played into the PMU with precise GPS synchronization. Timing flags included with the test signal provide correlate the test signals and the PMU output. This allows accurate comparison of the phasor model with the value estimated by the PMU for accurate performance analysis. The timing flags also facilitate programmed plot and report generation.

  10. The effects of symbiotic therapy on anthropometric measures, body composition and blood pressure in patient with metabolic syndrome: a triple blind RCT.

    Science.gov (United States)

    Rabiei, Samira; Shakerhosseini, Rahebeh; Saadat, Navid

    2015-01-01

    Increase in prevalence of obesity and type 2 diabetes which are of the main risk factors of metabolic syndrome, is not only the result of changes in genetic, diet or physical activity, but also an imbalance of micro flora may play an important role. Therefore, alteration of micro flora using pre/probiotic is considered as a new strategy for treatment of metabolic disorders. The current study is a triple blind randomized controlled trial. 46 patients from both sexes, who fulfilled inclusion criteria, randomly categorized into intervention or placebo group. The intervention and placebo groups consumed 2 probiotic capsules or 2 placebo capsules during 3 months, respectively. Both groups received a weight loss diet, according to their adjusted ideal body weight. Anthropometric, body composition, blood pressure and nutritional measurements were done in the beginning, at 6th week, and at the end of the study. T-test and paired-t test were used for statistical analysis. 40 patients completed the study. BMI, WC, HC, fat mass, lean mass and blood pressure were reduced in all participants (p< 0.05). Systolic blood pressure in symbiotic group was less than placebo group, significantly (p< 0.05). The trend of weight loss in symbiotic group continued at least for 12 weeks while it was stopped at week 6 in placebo group. Symbiotic supplement with the weight loss diet had synergistic effects on improvement in systolic blood pressure and anthropometric measurements. Based on our findings, symbiotic can postpone plateau phase of weight loss and it may prevent resistance to further weight loss.

  11. Standardization in measurement philosophical, historical and sociological issues

    CERN Document Server

    Schlaudt, Oliver

    2015-01-01

    The application of standard measurement is a cornerstone of modern science. In this collection of essays, standardization of procedure, units of measurement and the epistemology of standardization are addressed by specialists from sociology, history and the philosophy of science.

  12. Anthropometric Indicators Predict Metabolic Syndrome Diagnosis in Maintenance Hemodialysis Patients.

    Science.gov (United States)

    Vogt, Barbara Perez; Ponce, Daniela; Caramori, Jacqueline Costa Teixeira

    2016-06-01

    Obesity has been considered the key in metabolic syndrome (MetS) development, and fat accumulation may be responsible for the occurrence of metabolic abnormalities in hemodialysis patients. The use of gold-standard methods to evaluate obesity is limited, and anthropometric measures may be the simplest methods. However, no study has investigated the association between anthropometric indexes and MetS in these patients. Therefore, the aim was to determine which anthropometric indexes had the best association and prediction for MetS in patients undergoing hemodialysis. Cross-sectional study that included patients older than 18 years, undergoing hemodialysis for at least 3 months. Patients with liver disease and cancer or those receiving corticosteroids or antiretroviral therapy were excluded. Diagnostic criteria from Harmonizing Metabolic Syndrome were used for the diagnosis of MetS. Anthropometric indexes evaluated were body mass index (BMI); percent standard of triceps skinfold thickness and of middle arm muscle circumference; waist circumference (WC); sagittal abdominal diameter; neck circumference; waist-to-hip, waist-to-thigh, and waist-to-height ratios; sagittal index; conicity index; and body fat percentage. Ninety-eight patients were included, 54.1% male, and mean age was 57.8 ± 12.9 years. The prevalence of MetS was 74.5%. Individuals with MetS had increased accumulation of abdominal fat and general obesity. Waist-to-height ratio was the variable independently associated with MetS diagnosis (odds ratio, 1.21; 95% confidence interval, 1.09-1.34; P < .01) and that better predicts MetS, followed by WC and BMI (area under the curve of 0.840, 0.836, and 0.798, respectively, P < .01). Waist-to-height ratio was the best anthropometric predictor of MetS in maintenance hemodialysis patients. © 2015 American Society for Parenteral and Enteral Nutrition.

  13. Making and Measuring the California History Standards

    Science.gov (United States)

    Fogo, Bradley

    2011-01-01

    The California history and social science standards-based reform has been touted as the "gold standard" for state history curricula. But the standards, framework, and tests that constitute this reform provide inconsistent and contradictory criteria for teaching and assessing history and social science. An examination of the political…

  14. Prediction of fat-free mass and percentage of body fat in neonates using bioelectrical impedance analysis and anthropometric measures: validation against the PEA POD.

    Science.gov (United States)

    Lingwood, Barbara E; Storm van Leeuwen, Anne-Martine; Carberry, Angela E; Fitzgerald, Erin C; Callaway, Leonie K; Colditz, Paul B; Ward, Leigh C

    2012-05-01

    Accurate assessment of neonatal body composition is essential to studies investigating neonatal nutrition or developmental origins of obesity. Bioelectrical impedance analysis or bioimpedance analysis is inexpensive, non-invasive and portable, and is widely used in adults for the assessment of body composition. There are currently no prediction algorithms using bioimpedance analysis in neonates that have been directly validated against measurements of fat-free mass (FFM). The aim of the study was to evaluate the use of bioimpedance analysis for the estimation of FFM and percentage of body fat over the first 4 months of life in healthy infants born at term, and to compare these with estimations based on anthropometric measurements (weight and length) and with skinfolds. The present study was an observational study in seventy-seven infants. Body fat content of infants was assessed at birth, 6 weeks, 3 and 4·5 months of age by air displacement plethysmography, using the PEA POD body composition system. Bioimpedance analysis was performed at the same time and the data were used to develop and test prediction equations for FFM. The combination of weight+sex+length predicted FFM, with a bias of impedance in prediction algorithms resulted in small improvements in prediction of FFM, reducing the bias to < 50 g and limits of agreement to < 9 %. Skinfold measurements performed poorly at all ages.

  15. Evaluation of anthropometric accuracy and reliability using different three-dimensional scanning systems

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    2011-01-01

    The aim of this study was to evaluate the accuracy and reliability of standard anthropometric linear measurements made with three different three-dimensional scanning systems namely laser surface scanning (Minolta Vivid 900), cone beam computed tomography (CBCT), 3D stereo-photogrammetry (Di3D

  16. Modeling transitions in body composition: the approach to steady state for anthropometric measures and physiological functions in the Minnesota human starvation study.

    Science.gov (United States)

    Hargrove, James L; Heinz, Grete; Heinz, Otto

    2008-10-07

    This study evaluated whether the changes in several anthropometric and functional measures during caloric restriction combined with walking and treadmill exercise would fit a simple model of approach to steady state (a plateau) that can be solved using spreadsheet software (Microsoft Excel). We hypothesized that transitions in waist girth and several body compartments would fit a simple exponential model that approaches a stable steady-state. The model (an equation) was applied to outcomes reported in the Minnesota starvation experiment using Microsoft Excel's Solver function to derive rate parameters (k) and projected steady state values. However, data for most end-points were available only at t = 0, 12 and 24 weeks of caloric restriction. Therefore, we derived 2 new equations that enable model solutions to be calculated from 3 equally spaced data points. For the group of male subjects in the Minnesota study, body mass declined with a first order rate constant of about 0.079 wk-1. The fractional rate of loss of fat free mass, which includes components that remained almost constant during starvation, was 0.064 wk-1, compared to a rate of loss of fat mass of 0.103 wk-1. The rate of loss of abdominal fat, as exemplified by the change in the waist girth, was 0.213 wk-1.On average, 0.77 kg was lost per cm of waist girth. Other girths showed rates of loss between 0.085 and 0.131 wk-1. Resting energy expenditure (REE) declined at 0.131 wk-1. Changes in heart volume, hand strength, work capacity and N excretion showed rates of loss in the same range. The group of 32 subjects was close to steady state or had already reached steady state for the variables under consideration at the end of semi-starvation. When energy intake is changed to new, relatively constant levels, while physical activity is maintained, changes in several anthropometric and physiological measures can be modeled as an exponential approach to steady state using software that is widely available. The 3

  17. Cardiac abnormalities and facial anthropometric measurements in children from the Free State and Northern Cape provinces of South Africa with chromosome 22q11.2 microdeletion.

    Science.gov (United States)

    Brown, S C; Henderson, B D; Buys, D A; Theron, M; Long, M A; Smit, F

    2010-01-01

    Microdeletions of chromosome 22 are common and have a prevalence of at least 1/4 000. Cardiac abnormalities, abnormal facial features and palatal abnormalities are frequently present in these patients. To describe the cardiac lesions and selected measurable facial features in children from the Free State and Northern Cape presenting at the Cardiology Unit of the Universitas Academic Hospital complex in Bloemfontein. This was a prospective study in which patients with abnormal facial characteristics were tested using a fluorescence in situ hybridisation (FISH) probe for the 22q11.2 microdeletion. Forty children tested positive for the microdeletion. All patients underwent an echocardiogram and where possible, facial anthropometric measurements were performed. The median age at diagnosis was 3.6 years (range 0.04 years, i.e. 2 weeks to 16.2 years). Tetralogy with or without pulmonary atresia was diagnosed in 43% (n = 17) of the children and truncus arteriosus in 20% (n = 8). A rightsided aortic arch was present in 43% (n = 17) of the patients. Mid-facial height was slightly longer (median = 1.0; range -0.5 to 3.3) and width narrower (median = -1.4; range -2.2 to 0.1) than normal. Ear height and width were notably small compared to normal, with median -scores = -3.3 (range -4.8 to -2.6) and = -2.4 (range -3.4 to -1.4), respectively. Microdeletions of chromosome 22q11 are present in children from the Free State and Northern Cape. Conotruncal cyanotic heart lesions, especially tetralogy with or without pulmonary atresia and truncus arteriosus were the most frequent congenital cardiac diagnoses. A right-sided aortic arch was also commonly present in these children. Facial features varied and small ears were the most noteworthy anthropometric feature. A right-sided aortic arch with or without a congenital cardiac lesion, a long, narrow mid-face and small ears should alert the physician to the possibility of a microdeletion on the long arm of chromosome 22.

  18. Current issues with standards in the measurement and documentation of human skeletal anatomy.

    Science.gov (United States)

    Magee, Justin; McClelland, Brian; Winder, John

    2012-09-01

    Digital modeling of human anatomy has become increasingly important and relies on well-documented quantitative anatomy literature. This type of documentation is common for the spine and pelvis; however, significant issues exist due to the lack of standardization in measurement and technique. Existing literature on quantitative anatomy for the spine and pelvis of white adults (aged 18-65 years, separated into decadal categories) was reviewed from the disciplines of anatomy, manipulative therapy, anthropometrics, occupational ergonomics, biomechanics and forensic science. The data were unified into a single normative model of the sub-axial spine. Two-dimensional orthographic drawings were produced from the 590 individual measurements identified, which informed the development of a 3D digital model. A similar review of full range of motion data was conducted as a meta-analysis and the results were applied to the existing model, providing an inter-connected, articulated digital spine. During these data analysis processes several inconsistencies were observed accompanied by an evidential lack of standardization with measurement and recording of data. These have been categorized as: anatomical terminology; scaling of measurements; measurement methodology, dimension and anatomical reference positions; global coordinate systems. There is inconsistency in anatomical terminology where independent researchers use the same terms to describe different aspects of anatomy or different terms for the same anatomy. Published standards exist for measurement methods of the human body regarding spatial interaction, anthropometric databases, automotive applications, clothing industries and for computer manikins, but none exists for skeletal anatomy. Presentation of measurements often lacks formal structure in clinical publications, seldom providing geometric reference points, therefore making digital reconstruction difficult. Published quantitative data does not follow existing

  19. Study on the relationship between the thickness of the anterior cruciate ligament, anthropometric data and anatomical measurements on the knee

    Directory of Open Access Journals (Sweden)

    Victor Marques de Oliveira

    2016-04-01

    Full Text Available OBJECTIVES: To ascertain thickness measurements on the anterior cruciate ligament (ACL in its middle third on magnetic resonance imaging (MRI scans and to assess whether there is any association between variations in ligament thickness and patients' heights and ages, along with variations in the anatomical measurements on the knee. METHODS: MRI scans on 48 knees were evaluated. The anteroposterior size of the femoral condyles, interepicondylar distance, intercondylar distance and anteroposterior and mediolateral thicknesses of the ACL were measured. It was assessed whether there was any statistical relationship between ACL thickness and the patients' age, height or other measurements evaluated. RESULTS: The mean thickness of the middle third of the ACL was 4.5 mm in the sagittal plane and 4.3 mm in the frontal plane. The anteroposterior thickness of the ACL in its middle third had a positive relationship with the size of the lateral condyle. The mediolateral thickness of the ACL in its middle third had a positive relationship with the size of the lateral condyle and with the intercondylar distance in the axial plane. There was no relationship between the thickness of the ACL and the patients' age or height. CONCLUSION: The thickness of the ACL presented positive associations with the size of the lateral femoral condyle and the intercondylar distance.

  20. Relationship of anthropometric measures of fatness to serum lipid concentration in school children: A cross sectional study

    Directory of Open Access Journals (Sweden)

    CS Yilgwan

    2017-01-01

    Full Text Available Background Body fat distribution is associated with adverse health outcomes in adults. Research has shown that these usually begin in childhood. We thus set out to examine the relationship between body fat and the occurrence of adverse serum lipid profile in apparently healthy Nigerian School children. Methods This was a cross sectional observational study carried out between December 2013 and June 2014. Stratified random sampling was used in the recruitment process. All children present in school were eligible for selection except those on drugs known to predispose to dyslipidaemia. STATA version 14 was used for all statistical analysis. Descriptive statistics was used to calculate means and proportions while linear regression was used in investigating relationship between serum lipid concentration and measures of adiposity. Logistic regression was used to predict the relationship between measures of adiposity and adverse serum lipid status. Results A total of 240 school age children (56% females aged 6‐12 years (mean age=9.2±1.65 years were studied. Total serum cholesterol was significantly associated with percent body fat(R=0.07; p=0.01 and hip circumference (R=0.02; p=0.023. Serum low density lipoprotein was significantly associated with percent body fat(R=0.05; p=0.04, waist circumference (R=0.02; p=0.01 and triceps diameter(R=0.06;p=0.04. Similarly, serum triglycerides was significantly associated with waist height ratio (R=0.64; p=0.04. No significant relationship was seen between high density lipoprotein cholesterol and any of the measures of adiposity. Logistic regression using those variables that have been consistently shown to be significantly related to serum lipid measures demonstrated only WC (OR=0.9; 95% CI=0.8‐0.99 and triceps diameter (OR=1.26; 95% CI=1.02‐1.56 significantly predicted bad total serum cholesterol status. Conclusions Subcutaneous adiposity and waist circumference are more reliable measures of serum lipids

  1. Overweight and obesity in New Caledonian adults: Results from measured and adjusted self-reported anthropometric data.

    Science.gov (United States)

    Corsenac, Philippe; Annesi-Maesano, Isabella; Hoy, Damian; Roth, Adam; Rouchon, Bernard; Capart, Isabelle; Taylor, Richard

    2017-11-01

    To estimate the overweight (OW) and obesity (Ob) prevalence and associated socio-demographic risk factors in New Caledonian adults aged 18-67years. From a randomly selected cross-sectional population survey, self-reported (n=2513) and measured (n=736) height and weight data were collected. Separate linear regression analyses for measured weight and height were performed, using cases with both self-reported weight and height and socio-demographic variables. The final weight and height assigned to each case was either measured or predicted from the regression (n=2075). OW prevalence was defined as: Body Mass Index (BMI) ≥25 and adult population. Prevalence and Odds ratios (ORs) were calculated by gender, and adjusted for socio-demographic variables, to assess differentials in OW, Ob and OW-Ob, using multinomial and logistic regressions. Male (M) OW was 35% (95% CI: 31-38), Ob 29% (95% CI: 26-32) and OW-Ob 64% (95% CI: 60-67); female (F) OW was 26% (95% CI: 23-28), Ob 34% (95% CI: 31-37) and OW-Ob 60% (95% CI: 57-63). Compared to Melanesians (OR=1.0) for male/female: Polynesians had the highest prevalence of OW (1.7/1.5), Ob (4.7/3.5), and OW-Ob (3.0/2.5); New Caledonian-born Europeans had greater OW, Ob and OW-Ob (0.3/0.4) than immigrant Europeans (0.2/0.2). Findings contribute to obesity comparisons with other Pacific Islands, and they establish trends in New Caledonia for targeting policies and strategies of prevention. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Association of Anthropometric Measures with Cardiovascular Risk Factors and Metabolic Syndrome in Normal-Weight Children and Adolescents: The CASPIAN III Study

    Directory of Open Access Journals (Sweden)

    Mostafa Qorbani

    2013-10-01

    Full Text Available Objective: This nationwide study was conducted to determine the association of anthropometric measures with cardiovascular risk factors and metabolic syndrome (MetS in Iranian normal-weight children and adolescents. Methods: We analyzed the data of 3,565 children and adolescents (50.3% boys, aged 10-18 years, with a normal BMI (5th-84th percentile obtained from the third survey of ‘Childhood and Adolescence Surveillance and Prevention of Adult Non-communicable Disease' (CASPIAN III study. The diagnostic criteria for MetS were defined by the International Diabetes Federation consensus. Results: The prevalence of MetS for 10- to 13.9-year-old boys, 14- to 18-year-old boys, 10- to 13.9-year-old girls, and 14- to 18-year-old girls were 1.4, 2.8, 2.3, and 3.3%, respectively. After adjustment for age and sex, each unit increase in BMI (within normal range and waist circumference increased the odds of MetS from 6 to 72% and from 1 to 20%, respectively. The dominant pattern of dyslipidemia among the participants was high triglycerides and low high-density lipoprotein cholesterol. Conclusion: This study complements recent research about the high frequency of metabolic risk factors among normal-weight individuals in the pediatric age group.

  3. Comparison of 3D laser-based photonic scans and manual anthropometric measurements of body size and shape in a validation study of 123 young Swiss men

    Directory of Open Access Journals (Sweden)

    Nikola Koepke

    2017-02-01

    Full Text Available Background Manual anthropometric measurements are time-consuming and challenging to perform within acceptable intra- and inter-individual error margins in large studies. Three-dimensional (3D laser body scanners provide a fast and precise alternative: within a few seconds the system produces a 3D image of the body topography and calculates some 150 standardised body size measurements. Objective The aim was to enhance the small number of existing validation studies and compare scan and manual techniques based on five selected measurements. We assessed the agreement between two repeated measurements within the two methods, analysed the direct agreement between the two methods, and explored the differences between the techniques when used in regressions assessing the effect of health related determinants on body shape indices. Methods We performed two repeated body scans on 123 volunteering young men using a Vitus Smart XXL body scanner. We manually measured height, waist, hip, buttock, and chest circumferences twice for each participant according to the WHO guidelines. The participants also filled in a basic questionnaire. Results Mean differences between the two scan measurements were smaller than between the two manual measurements, and precision as well as intra-class correlation coefficients were higher. Both techniques were strongly correlated. When comparing means between both techniques we found significant differences: Height was systematically shorter by 2.1 cm, whereas waist, hip and bust circumference measurements were larger in the scans by 1.17–4.37 cm. In consequence, body shape indices also became larger and the prevalence of overweight was greater when calculated from the scans. Between 4.1% and 7.3% of the probands changed risk category from normal to overweight when classified based on the scans. However, when employing regression analyses the two measurement techniques resulted in very similar coefficients, confidence

  4. Association of Anthropometric Indices of Obesity with Hypertension in Chinese Elderly: An Analysis of Age and Gender Differences.

    Science.gov (United States)

    Wang, Qian; Xu, Lingzhong; Li, Jiajia; Sun, Long; Qin, Wenzhe; Ding, Gan; Zhu, Jing; Zhang, Jiao; Yu, Zihang; Xie, Su

    2018-04-19

    This study aims to explore the association of anthropometric indices of obesity with hypertension in Chinese elderly and its possible gender and age differences. A total of 7070 adults age 60 or older were interviewed in a cross-sectional study conducted in 2017. Anthropometric indices for each participant were measured by using standard methods of trained doctoral/master students. We performed two binary logistic regression models to examine the association of the nine different anthropometric indices and hypertension by gender. Lastly, analyses were performed in two steps stratified for age. Comparing individuals with and without hypertension, there were statistically significant differences in anthropometric indices except height, a body shape index (ABSI), and hip index (HI) in males; and except height in females. There were gender differences in the relationship between anthropometric indices and the prevalence of hypertension in Chinese older adults. After stratification by age, the associations of all anthropometric indices became weaker, disappeared, or even went in the opposite direction. Furthermore, body mass index (BMI) in men (except individuals older than 80) and hip circumference (HC) in women showed a significant impact on the risk of hypertension. The association of anthropometric indices of obesity with hypertension in Chinese elderly differ by gender and age. These findings indicate a need to develop gender-specific strategies for the male and female elderly in the primary and secondary prevention of hypertension.

  5. Overweight and obesity in students of a dental college of Karachi: lifestyle influence and measurement by an appropriate anthropometric index.

    Science.gov (United States)

    Hingorjo, Mozaffer Rahim; Syed, Sadiqa; Qureshi, Masood Anwar

    2009-08-01

    To compare body mass index (BMI), waist circumference (WC), and body fat percentage (%BF), as index of overweight and obesity in young adults. We also intended to find an association between lifestyle behaviours and obesity. A cross-sectional study was conducted at Fatima Jinnah Dental College, Karachi, during 2007 to 2008, with 192 first year dental students, (18-21years) of high socioeconomic class. All were questioned regarding lifestyle behaviours. Overweight and obesity were estimated by measuring %BF, BMI, and WC. For %BF, skinfold thickness was measured using skinfold calipers. BMI > or = 23.0-24.9 kg/m2 was taken as overweight and > or = 25.0 kg/m2 as obese (Asians criteria proposed by Western Pacific Regional Office of World Health Organization). WC using Asian cutoff values for overweight and obesity were: males > or = 78 cm and > or = 90 cm; females > or = 72 cm and > or = 80 cm, respectively. Body fat percentage used to define overweight and obesity was: males 22.1-27.0 and > 27.1; females 27.1-32.0 and > 32.1, respectively. Pearson's correlation was done between the BMI, WC and %BF with statistical significance taken at P obese. Obesity was underpredicted by BMI when compared to skinfold calipers method. The obese were seen to skip breakfast more often [odds ratio (OR): 2.39], take frequent snacks (OR: 1.58), watch television more (OR: 1.58), and were physically less active than their non-obese counterparts. Body fat percentage using skinfold caliper is a reliable index of obesity. Lack of sleep and skipping of breakfast, are prominent promoters of obesity, in addition to other lifestyle behaviours.

  6. Interactions between Neighbourhood Urban Form and Socioeconomic Status and Their Associations with Anthropometric Measurements in Canadian Adults

    Science.gov (United States)

    Friedenreich, Christine; McLaren, Lindsay; Potestio, Melissa; Sandalack, Beverly; Csizmadi, Ilona

    2017-01-01

    Neighbourhood-level socioeconomic composition and built context are correlates of weight-related behaviours. We investigated the relations between objective measures of neighbourhood design and socioeconomic status (SES) and their interaction, in relation to self-reported waist circumference (WC), waist-to-hip ratio, and body mass index (BMI) in a sample of Canadian adults (n = 851 from 12 Calgary neighbourhoods). WC and BMI were higher among residents of disadvantaged neighbourhoods, independent of neighbourhood design (grid, warped grid, and curvilinear street patterns) and individual-level characteristics (sex, age, education, income, dog ownership, marital status, number of dependents, motor vehicle access, smoking, sleep, mental health, physical health, and past attempts to modify bodyweight). The association between neighbourhood-level SES and WC was modified by neighbourhood design; WC was higher in disadvantaged-curvilinear neighbourhoods and lower in advantaged-grid neighbourhoods. Policies making less obesogenic neighbourhoods affordable to low socioeconomic households and that improve the supportiveness for behaviours leading to healthy weight in low socioeconomic neighbourhoods are necessary. PMID:29056976

  7. A Study on Anthropometric Measurements, Blood Pressure, Blood Sugar and Food Intakes Among Different Social Status and Ethnicities

    Directory of Open Access Journals (Sweden)

    Jafarirad

    2016-09-01

    Full Text Available Background Metabolic syndrome is a disorder that increases the risk of cardiovascular disease and diabetes. Objectives The aim of the study was to evaluate some risk factors of the metabolic syndrome and food intakes among people who lived in Ahvaz City, Iran. Methods It was a filed study that was conducted on 211 subjects who participated in health exhibition. Socioeconomic status and ethnicity were asked by a general questionnaire. Weight, height, body mass index, waist circumference (WC and WC to hip circumference ratio (WHR were obtained. Blood sugar was measured by a glucometer. Systolic and diastolic blood pressures were obtained and dietary intakes were assessed by a brief instrument. Results There was a significant difference in weight, height, WC, WHR and systolic blood pressure among different jobs. Workers had more intakes of cake and sweets. Arab subjects had more intakes of bread and fishes and Persians more intakes of vegetables. Soda, chocolate and candy were more consumed by Kurd ethnicity. Conclusions Job may be accounted as an important effective socioeconomic factor related to metabolic syndrome risk factors; also different cultures due to different ethnicities may have an influence on lifestyle and dietary intakes.

  8. NUTRITIONAL ESTIMATES OF SCHOOL GOING CHILDREN BASED ON ANTHROPOMETRIC MEASUREMENTS: STUDY FROM A RURAL AREA OF VARANASI

    Directory of Open Access Journals (Sweden)

    M K Gupta

    2011-12-01

    Full Text Available Background: With the adoption of western lifestyle the problem of overweight and obesity is gradually increasing in children, while problem of malnutrition is persisting continuously in the country. With this background a school based cross sectional study was conducted to assess the nutritional status of school going children in a rural area: Chiraigaon block of Varanasi. Study period: July 2010 to September 2010 Methods: A school-based study with cross-sectional design was adopted. A total of 1448 school children were examined from 3 middle-schools that were selected by simple random sampling method. Height and weight of the children were measured, and BMI and other parameters were assessed. Results: On applying the BMI-for-age criteria, twelve percent of the children (12.4% boys and 11.1% girls were found underweight while 5.4% were overweight or obese (5.71% of the boys and 4.63% of the girls. But when the previous WHO’s BMI classification was used, 86.5% children had BMI <18.5 (88.4% of total boys and 81.9% of all girls. Conclusion: Nutritional status of school going children based on WHO criteria of BMI for age has been satisfactory. However, this approach needs scientific validation by undertaking a multi-centric study.

  9. Projection of Anthropometric Correlation for Virtual Population Modelling

    DEFF Research Database (Denmark)

    Rasmussen, John; Waagepetersen, Rasmus Plenge; Rasmussen, Kasper Pihl

    2017-01-01

    A new statistical method for generation of virtual populations based on anthropometric parameters is developed. The method addresses the problem that most anthropometric information is reported in terms of summary data such as means and standard deviations only, while the underlying raw data, and...

  10. Predicting Forearm Physical Exposures During Computer Work Using Self-Reports, Software-Recorded Computer Usage Patterns, and Anthropometric and Workstation Measurements.

    Science.gov (United States)

    Huysmans, Maaike A; Eijckelhof, Belinda H W; Garza, Jennifer L Bruno; Coenen, Pieter; Blatter, Birgitte M; Johnson, Peter W; van Dieën, Jaap H; van der Beek, Allard J; Dennerlein, Jack T

    2017-12-15

    Alternative techniques to assess physical exposures, such as prediction models, could facilitate more efficient epidemiological assessments in future large cohort studies examining physical exposures in relation to work-related musculoskeletal symptoms. The aim of this study was to evaluate two types of models that predict arm-wrist-hand physical exposures (i.e. muscle activity, wrist postures and kinematics, and keyboard and mouse forces) during computer use, which only differed with respect to the candidate predicting variables; (i) a full set of predicting variables, including self-reported factors, software-recorded computer usage patterns, and worksite measurements of anthropometrics and workstation set-up (full models); and (ii) a practical set of predicting variables, only including the self-reported factors and software-recorded computer usage patterns, that are relatively easy to assess (practical models). Prediction models were build using data from a field study among 117 office workers who were symptom-free at the time of measurement. Arm-wrist-hand physical exposures were measured for approximately two hours while workers performed their own computer work. Each worker's anthropometry and workstation set-up were measured by an experimenter, computer usage patterns were recorded using software and self-reported factors (including individual factors, job characteristics, computer work behaviours, psychosocial factors, workstation set-up characteristics, and leisure-time activities) were collected by an online questionnaire. We determined the predictive quality of the models in terms of R2 and root mean squared (RMS) values and exposure classification agreement to low-, medium-, and high-exposure categories (in the practical model only). The full models had R2 values that ranged from 0.16 to 0.80, whereas for the practical models values ranged from 0.05 to 0.43. Interquartile ranges were not that different for the two models, indicating that only for some

  11. Standards for reference reactor physics measurements

    International Nuclear Information System (INIS)

    Harris, D.R.; Cokinos, D.M.; Uotinen, V.

    1990-01-01

    Reactor physics analysis methods require experimental testing and confirmation over the range of practical reactor configurations and states. This range is somewhat limited by practical fuel types such as actinide oxides or carbides enclosed in metal cladding. On the other hand, this range continues to broaden because of the trend of using higher enrichment, if only slightly enriched, electric utility fuel. The need for experimental testing of the reactor physics analysis methods arises in part because of the continual broadening of the range of core designs, and in part because of the nature of the analysis methods. Reactor physics analyses are directed primarily at the determination of core reactivities and reaction rates, the former largely for reasons of reactor control, and the latter largely to ensure that material limitations are not violated. Errors in these analyses can be regarded as being from numerics, from the data base, and from human factors. For numerical, data base, and human factor reasons, then, it is prudent and customary to qualify reactor physical analysis methods against experiments. These experiments can be treated as being at low power or at high power, and each of these types is subject to an American National Standards Institute standard. The purpose of these standards is to aid in improving and maintaining adequate quality in reactor physics methods, and it is from this point of view that the standards are examined here

  12. South Korean anthropometric data and survey methodology: 'Size Korea' project.

    Science.gov (United States)

    Kim, Jung Yong; You, Jae Woo; Kim, Mi Sook

    2017-11-01

    Considering the many emerging markets in East Asia, access to contemporary anthropometric data for this region is important for designers and manufacturers seeking to produce the best fitting products and living environments for consumers. The purpose of this paper is to describe Korean anthropometric data collection and survey techniques for those who are interested in ethnic characteristics, conducting surveys, and formulating ergonomic product designs for South Korean and, more broadly, East Asian populations. The Size Korea survey was conducted in 2003-2004 and 2010. A total of 14,200 civilians aged 0-90 years participated in the survey, with 119 body and weight dimensions measured in 2004. Twenty new dimensions from Inbody measurement were added in 2010 and the data were continuously updated. We referred to ISO 7250, 8559 and 15535 to ensure validity and reliability. Fifty major body dimensions, including weight, are summarised in this paper, and 34 of these dimensions can be compared with 11 multinational data already reported  in other publications. Practitioner Summary: This paper presents the up-to-date anthropometric database of East Asian physical characteristics and survey methodology. These data satisfy the ISO standards and comprise 50 physical dimensions including weight. Thirty-four dimensions of these can be directly compared with available multinational data.

  13. Medidas e proporções antropométricas orofaciais de crianças respiradoras orais Anthropometric orofacial measurements and proportions in mouth breathing children

    Directory of Open Access Journals (Sweden)

    Débora Martins Cattoni

    2008-06-01

    Full Text Available OBJETIVO: Descrever as medidas e proporções orofaciais de crianças respiradoras orais e comparar a média do lado direito da face com a média do lado esquerdo da face, segundo a idade. MÉTODOS: Participaram 100 crianças, de ambos os sexos, com idades entre sete anos e 11 anos e 11 meses, leucodermas, em dentição mista, com diagnóstico de respiração oral. As crianças foram submetidas à avaliação antropométrica, sendo que as medidas orofaciais obtidas foram lábio superior, lábio inferior, filtro, terço superior da face, terço médio da face, terço inferior da face e lados da face. O instrumento utilizado foi o paquímetro eletrônico digital da marca Starrett, Série 727. RESULTADOS: Não houve diferença estatisticamente significativa entre as médias das medidas antropométricas orofaciais das crianças respiradoras orais, segundo a idade, com exceção do terço médio da face e dos lados da face. Não houve diferença estatisticamente significativa entre as médias das proporções orofaciais das crianças respiradoras orais, com exceção da proporção entre o terço superior da face e o terço médio da face. Não houve diferença estatisticamente significativa entre as médias dos lados da face, segundo a idade. CONCLUSÕES: Não houve diferença estatisticamente entre a maioria das médias das medidas e proporções orofaciais de crianças respiradoras orais, segundo a idade.PURPOSE: To describe the orofacial measurements and proportions of mouth breathing children and to compare the average of the right side of the face to the average of the left side of the face, according to age. METHODS: One hundred children of both sexes, with ages ranging from seven to 11 years and 11 months, leukoderms, in mixed dentition period and with mouth breathing diagnosis participated in the study. The children were submitted to anthropometric assessment, and the orofacial measurements obtained were upper lip, lower lip, philtrum, upper

  14. Association between breakfast intake with anthropometric measurements, blood pressure and food consumption behaviors among Iranian children and adolescents: the CASPIAN-IV study.

    Science.gov (United States)

    Ahadi, Z; Qorbani, M; Kelishadi, R; Ardalan, G; Motlagh, M E; Asayesh, H; Zeynali, M; Chinian, M; Larijani, B; Shafiee, G; Heshmat, R

    2015-06-01

    The aim of this study is to assess the association between breakfast intake with anthropometric measurements and blood pressure among Iranian children and adolescents. The second goal is to investigate the correction of breakfast consumption with other food consumption behaviors. In this national survey, 13,486 children and adolescents, aged 6-18 years, were selected by multistage, cluster sampling method from rural and urban areas of 31 provinces of Iran (2011-2012). Physical measurements included height, weight, waist circumference, and blood pressure. Food habits were assessed by self-reported questionnaire. Breakfast frequency was defined as skippers (eating breakfast 0-2 days/week), semi-skippers (eating breakfast 3-4 days/week) and non-skippers (eating breakfast 5-7 days/week). The data were analyzed by the STATA package. Of the participants, 18.9%, 13.2% and 67.9%, were breakfast skippers, semi-skippers and non-skippers respectively. The prevalence of overweight and obesity among breakfast skippers were higher than non-skippers counterparts (P-value breakfast skippers and non-skippers group were 22.6% (CI 95%: 21-24.3) and 17.9% (CI 95%: 17-18.6), respectively. Blood pressure did not significantly differ between non-skippers students and breakfast skippers (P-value = 0.1). Non-skipping adolescents ate more fresh fruits, dried fruits, vegetables and drank milk more frequently compared with breakfast skipper; while the skippers showed a higher intake of salty snack, soft drinks, packed fruit juice and fast foods (all P-value breakfast consumption is significantly associated with lower body fatness and healthier dietary habits but that further study, using controlled intervention trials, is required to test whether this represents a causal relationship. Copyright © 2015. Published by Elsevier Ltd.

  15. Hematological indices and their correlation with fasting blood glucose level and anthropometric measurements in type 2 diabetes mellitus patients in Gondar, Northwest Ethiopia

    Directory of Open Access Journals (Sweden)

    Biadgo B

    2016-03-01

    Full Text Available Belete Biadgo,1 Mulugeta Melku,2 Solomon Mekonnen Abebe,3 Molla Abebe1 1School of Biomedical and Laboratory Sciences, Department of Clinical Chemistry, 2School of Biomedical and Laboratory Sciences, Department of Hematology and Immunohematology, 3Institute of Public Health, College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia Background: Diabetes mellitus is (DM a global public health problem and a complex disease characterized by chronic hyperglycemia that leads to long-term macrovascular and microvascular complications. Recent studies have reported the role of hematological indices in contributing to the vascular injury in diabetic patients. Thus, the aim of this study was to determine hematological indices and their correlation with fasting blood glucose level and anthropometric measurement in type 2 DM patients in comparison with healthy controls. Methods: A comparative cross-sectional study was conducted at the chronic illness clinic of Gondar University Hospital from February to April 2015. A total of 296 participants (148 cases and 148 healthy controls were selected using systematic random sampling technique. Data were collected using a pretested structured questionnaire. Fasting blood glucose levels and hematological indices were determined by using Bio Systems A25 and Sysmex-KX 21N analyzers, respectively. Independent sample t-test, Mann–Whitney U-test, and correlation statistics were used. A P-value <0.05 was considered as statistically significant. Result: There was significant difference in red blood cell distribution width (47.3±2.6 fL vs 45.2±3 fL between diabetic patients and controls. Total white blood cells in 103/µL (6.59±1.42 vs 5.56±1.38, absolute lymphocyte count in 103/µL (2.60±0.70 vs 2.04±0.63, and absolute neutrophil count in 103/µL (3.57±1.46 vs 3.11±1.04 increased significantly in diabetic patients compared with controls, respectively. Among platelet indices, mean platelet volume

  16. STANDARDS OF FUNCTIONAL MEASUREMENTS IN OCULAR TOXICOLOGY.

    Science.gov (United States)

    The visual system, like other sensory systems, may be a frequent target of exposure to toxic chemicals. A thorough evaluation of visual toxicity should include both structural and functional measures. Sensory evoked potentials are one set of neurophysiological procedures that...

  17. Anthropometrics, Physical Performance, and Injury Characteristics of Youth American Football

    OpenAIRE

    Caswell, Shane V.; Ausborn, Ashley; Diao, Guoqing; Johnson, David C.; Johnson, Timothy S.; Atkins, Rickie; Ambegaonkar, Jatin P.; Cortes, Nelson

    2016-01-01

    Background: Prior research has described the anthropometric and physical performance characteristics of professional, collegiate, and high school American football players. Yet, little research has described these factors in American youth football and their potential relationship with injury. Purpose: To characterize anthropometric and physical performance measures, describe the epidemiology of injury, and examine the association of physical performance measures with injury among children pa...

  18. The effect of almonds on anthropometric measurements and lipid profile in overweight and obese females in a weight reduction program: A randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Zohreh Abazarfard

    2014-01-01

    Full Text Available Background: Due to the wholesome benefits of nuts increased consumption of them has been recommended. However, because of nut′s high energy density, the role of them in the treatment of overweight and obesity is vague. This current clinical trial study aims to investigate the effects of a balanced hypocaloric almond-enriched diet (AED (almond group in comparison to a balanced hypocaloric nut-free diet (NFD (nut-free group on body weight and cardiovascular disease risk factors in women with body mass index (BMI >25 for 3-month. Materials and Methods: A total of 108 overweight and obese women were assigned in our 3-month randomized controlled trial. The subjects were randomly divided into two groups regarding a balanced hypocaloric diet with or without almond. The planned reduced calorie diets for both groups were identical except for the almond group who consumed 50 g of almonds daily. Anthropometric and laboratory measurements of the participants who completed the study were made prior to and at the end of the study. Results: A total of 100 subjects completed the study. Weight, BMI, waist circumference, waist to hip circumference ratio, total cholesterol, and triglyceride, total: High density lipoprotein-cholesterol (HDL-C, fasting blood sugar and diastolic blood pressure decreased significantly in the almond group compared to the nut-free group (P > 0.001. Greater reduction in low density lipoprotein-cholesterol (P > 0.002 and systolic blood pressure (P > 0.001 and greater increase in HDL-C (P = 0.001 were found in the nut-free group. Conclusion: The balanced hypocaloric AED in comparison to the balanced hypocaloric NFD led to a greater weight-loss and overall better improvements in studied cardiovascular disease risk factors.

  19. Participant Adherence Indicators Predict Changes in Blood Pressure, Anthropometric Measures, and Self-Reported Physical Activity in a Lifestyle Intervention: HUB City Steps

    Science.gov (United States)

    Thomson, Jessica L.; Landry, Alicia S.; Zoellner, Jamie M.; Connell, Carol; Madson, Michael B.; Molaison, Elaine Fontenot; Yadrick, Kathy

    2015-01-01

    The objective of this secondary analysis was to evaluate the utility of several participant adherence indicators for predicting changes in clinical, anthropometric, dietary, fitness, and physical activity (PA) outcomes in a lifestyle intervention, HUB City Steps, conducted in a southern, African American cohort in 2010. HUB City Steps was a…

  20. A comparative study of performance measurement standards of railway operator

    Directory of Open Access Journals (Sweden)

    Pongjirawut Siripong

    2017-01-01

    Full Text Available The European standard (EN 13816, is one of the widely accepted standards for measuring the quality of public passenger transport (PPT service. EN 13816 indicates 8 measurement criteria, 29 sub-criteria and 193 Key Performance Indicators (KPIs to be used to measure the performance of railway operators. Nowadays, there are other addition criteria beyond EN13816, developed by various organisations. This research firstly aims to explore the service performance measurement of railway operators used by actual railway operators at international level and in Thailand. After an intensive review of performance measurement standards, 9 standards are compiled and compared in terms of criteria, sub-criteria and KPIs using a cluster analysis methodology. The result found additional performance measurement aspects at 2 sub-criteria and 91 KPIs in addition to EN 13816. This research summarized and compared different performance measurement standards to measure service quality of metro rail line.

  1. ANTHROPOMETRICAL STATUS AND GENDER DIFFERENCES AT 12 YEARS OF AGE

    Directory of Open Access Journals (Sweden)

    Ilir Gllareva

    2015-05-01

    Full Text Available The aim of this study is to verify the current anthropometrical status of the pupils of the age 12, as well as to compare it with the standards of raising in accordance with the WHO standards. In the study were included 62 pupils (42 male and 20 female. The anthropometric tests were done in height, weight, biacromial and elbow breadth, subcutaneous adipose tissue at the : suprailiac skinfold; subscapular skinfold; triceps skinfold, as well as the abdominal circumference. The results showed that there was a heterogenic distribution of results, especially in the body weight, where the distribution between the minimal and maximal results is 28-70 kg, with the average 43, 14 ± 9, 78 of standard deviation with the male pupils, while with the female pupils was noticed more homogenous group and the standard deviation was significantly lower than with the female pupils in all variables. The findings show that almost in all measured variables female pupils are more developed at this age, especially the body high, body weight and subcutaneous adipose tissue, while as regards the abdominal circumference and body breadth, the male pupils are more developed. Comparison of symbolic sample of this research with the WHO data shows an approximate trend of raising and development of children which were included in this research, and the difference is as follows: Female pupils age 12, body height=151.97 cm

  2. Prostate cancer detected by screening in a semi urban community in Southeast Nigeria: Correlations and associations between anthropometric measurements and prostate-specific antigen

    Directory of Open Access Journals (Sweden)

    Fred O Ugwumba

    2017-01-01

    Full Text Available Context: Prostate cancer (PCa is frequently diagnosed at advanced stages in Nigeria. Aims: To determine the screen detected PCa prevalence in a suburban community and explore any relationships between prostate-specific antigen (PSA and anthropometric measurements. Settings and Design: Nsukka is a town and local government area (LGA in Southeast Nigeria in Enugu State. Towns that share a common border with Nsukka are Edem Ani, Alor-uno, Opi, Orba, and Ede-Oballa. Nsukka LGA has an area of 1810 km2 and a population of 309,633 at the 2006 census. All consecutive responders who met the inclusion criteria were recruited. Subjects and Methods: A screening outreach was conducted in one location in Nsukka. PSA testing and digital rectal examinations were performed. Height and weight were measured and body mass index (BMI was calculated. Statistical Analysis Used: Results were subjected to statistical analysis using SPSS 20 (IBM SPSS Statistics for Windows, Version 20.0. Armonk, NY, USA. Categorical data were analyzed using the Chi-square test, with significance level set at P< 0.05. Pearson's correlation was conducted for interval data (P < 0.05. Results: One-hundred and sixty men met the inclusion criteria and were screened. Age range was 40–81 years; PSA range was 1.20–33.9 ng/ml. Digital rectal examinations (DREs was abnormal in 17 men. Median BMI was 27.49. A Pearson's correlation coefficient showed a significant correlation between age and PSA, r = 0.127; P ≤ 0.05, and DRE findings and PSA, r = 0.178; P ≤ 0.05. There was no significant correlation between height and PSA, r = −0.99; P = 0.211; weight and PSA, r = −0. 81 P = 0.308; and BMI and PSA, r = −0.066; P = 0.407. 8/21 men consented to prostate biopsy with three positive, giving a screen detected PCa prevalence of 1.875%. Conclusions: Screen detected PCa prevalence in high this population and efforts to improve early detection may be of value in improving treatment outcomes.

  3. Association between anthropometric parameters in relation to body ...

    African Journals Online (AJOL)

    Objective: Anthropometric indices are valid proxies for predicting the risk of metabolic and cardiovascular diseases across age groups and gender. The objective of the present work was to study some anthropometric measures of body mass and adiposity in male Nigerian adolescents. Methods: In a population of male ...

  4. An Anthropometrical Related Lower Body Explosive Power (LBEP ...

    African Journals Online (AJOL)

    In the prediction of lower body explosive power (LBEP), very few researchers have investigated the possibility of making use of anthropometric variables to compile prediction models. Therefore the purpose of this study was to develop a LBEP prediction model from several anthropometric measurements for a cohort of ...

  5. Anthropometric and Performance Perspectives of Female Competitive Surfing

    Directory of Open Access Journals (Sweden)

    Barlow Matthew John

    2016-09-01

    Full Text Available Purpose. To evaluate the anthropometric profiles of female surfers and to identify whether any anthropometrical factors might predict competitive ranking. Secondly, to evaluate the activity profile of female competitive surfing with respect to environmental conditions using Global Positioning System (GPS derived measures.

  6. Evaluation of Anthropometric Status of Hausas of Northern Nigeria ...

    African Journals Online (AJOL)

    Anthropometry is a branch of anthropology that deals with the measurements of various parts of human body which are expected to grow predictably and proportionately. The aim of this work was to study some of the anthropometric parameters of the Hausa people residing in Kano, northwestern Nigeria. Anthropometric ...

  7. Anthropometric indices and energy intakes of alcoholic adolescent ...

    African Journals Online (AJOL)

    The study assessed the nutritional status of alcoholics in relation to non-alcoholic adolescent students, as well as the relationship between alcohol consumption, and energy intake, and the anthropometric indices of the adolescent students of Abia state university. Anthropometric measurements (weight and height) of 513 ...

  8. The Effect of Gravidity on Anthropometric Indices of Pregnant ...

    African Journals Online (AJOL)

    Anthropometry in pregnancy is a comparative measure of size, proportion and composition of the body in relation to pregnancy. Anthropometric indices are useful in the assessment of nutritional status of pregnant women and predicting pregnancy outcome. To determine the effect of gravidity on anthropometric indices of ...

  9. Development of a standard for indoor radon measurements in Australia

    Energy Technology Data Exchange (ETDEWEB)

    O`Brien, R.S.; Solomon, S.B. [Australian Radiation Lab., Melbourne, VIC (Australia)

    1994-12-31

    A standard covering methodologies for the measurement of indoor radon and radon progeny concentrations in air in Australian buildings is currently under preparation as part of a set of standards covering total indoor air quality. This paper outlines the suggested methodology for radon and discusses some of the problems associated with the development of the standard. The draft standard recommends measurement of the radon concentration in air using scintillation cells, charcoal cups and solid state nuclear track detectors, and measurement of radon progeny concentration in air using the Rolle method or the Nazaroff method. 14 refs., 1 tab.

  10. Development of a standard for indoor radon measurements in Australia

    International Nuclear Information System (INIS)

    O'Brien, R.S.; Solomon, S.B.

    1994-01-01

    A standard covering methodologies for the measurement of indoor radon and radon progeny concentrations in air in Australian buildings is currently under preparation as part of a set of standards covering total indoor air quality. This paper outlines the suggested methodology for radon and discusses some of the problems associated with the development of the standard. The draft standard recommends measurement of the radon concentration in air using scintillation cells, charcoal cups and solid state nuclear track detectors, and measurement of radon progeny concentration in air using the Rolle method or the Nazaroff method. 14 refs., 1 tab

  11. Association between milk and milk product consumption and anthropometric measures in adult men and women in India: a cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Ambika Satija

    Full Text Available The nutritional aetiology of obesity remains unclear, especially with regard to the role of dairy products in developing countries.To examine whether milk/milk product consumption is associated with obesity and high waist circumference among adult Indians.Information on plain milk, tea, curd and buttermilk/lassi consumption assessed using a Food Frequency Questionnaire was obtained from the cross-sectional sib-pair designed Indian Migration Study (3698 men and 2659 women, conducted at four factory locations across north, central and south India. The anthropometric measures included were Body Mass Index (BMI and Waist Circumference (WC. Mixed-effect logistic regression models were conducted to accommodate sib-pair design and adjust for potential confounders.After controlling for potential confounders, the risk of being obese (BMI ≥ 25 kg/m(2 was lower among women (OR = 0.57;95%CI:0.43-0.76;p ≤ 0.0001 and men (OR = 0.67;95%CI: 0.51-0.87;p = 0.005, and the risk of a high WC (men: >90 cm; women: >80 cm was lower among men (OR = 0.71;95%CI:0.54-0.93;p = 0.005 and women (OR = 0.79;95%CI:0.59-1.05;p>0.05 who consume ≥1 portions of plain milk daily than those who do not consume any milk. The inverse association between daily plain milk consumption and obesity was also confirmed in sibling-pair analyses. Daily tea consumption of ≥ 1 portion was associated with obesity (OR = 1.51;95%CI:1.00-2.25;p>0.050 and high WC (OR = 1.65;95%CI:1.08-2.51;p>0.019 among men but not among women but there was no strong evidence of association of curd and buttermilk/lassi consumption with obesity and high waist circumference among both men and women.The independent, inverse association of daily plain milk consumption with the risk of being obese suggests that high plain milk intake may lower the risk of obesity in adult Indians. However, this is an observational finding and uncontrolled confounding cannot be excluded as an explanation for the association. Therefore

  12. 7 CFR 300.5 - International Standards for Phytosanitary Measures.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false International Standards for Phytosanitary Measures. 300.5 Section 300.5 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE INCORPORATION BY REFERENCE § 300.5 International Standards for Phytosanitary Measures. (a)...

  13. The use of personal values in living standards measures | Ungerer ...

    African Journals Online (AJOL)

    The Living Standards Measure (LSM), a South African marketing segmentation method, is a multivariate wealth measure based on standard of living. This article reports on whether a rationale can be found for the inclusion of psychological variables, particularly personal values, in this type of multivariate segmentation.

  14. Cassava household expenditure and anthropometric indices of ...

    African Journals Online (AJOL)

    In an attempt to verify the myth associated with cassava, that high consumption causes malnutrition, anthropometric measurements of 445 preschool children aged 0 - 5 years in 90 randomly selected farm households of cassava growing areas of Imo State were undertaken. Growth deviations (Z – scores) were calculated ...

  15. ORIGINAL ARTICLE Clinical, anthropometric, radiological and ...

    African Journals Online (AJOL)

    salah

    The phenotype of achondroplasia is related to disturbance in endochondral bone formation due to mutations in the fibroblast growth fac- tor receptor-3 (FGFR3) gene. Aim of the Work: Evaluation of the cardinal phenotypic features in achondro- plasia, the body physique using anthropometric measurements, the character-.

  16. The Relationship between Nutritional Status and Anthropometric ...

    African Journals Online (AJOL)

    Three hundred and six (306) children of both sexes aged 1-5 years were classified into three groups: Normal, protein-energy malnutrition (PEM) and vitamin deficiency (VD). The relative importance of the various anthropometric measurements was assessed in these three categories of children through comparison of their ...

  17. Anthropometric predictive equations for estimating body composition

    Science.gov (United States)

    Salamat, Mohammad Reza; Shanei, Ahmad; Salamat, Amir Hossein; Khoshhali, Mehri; Asgari, Mahdi

    2015-01-01

    Background: Precise and accurate measurements of body composition are useful in achieving a greater understanding of human energy metabolism in physiology and in different clinical conditions, such as, cardiovascular disease and overall mortality. Dual-energy x-ray absorptiometry (DXA) can be used to measure body composition, but the easiest method to assess body composition is the use of anthropometric indices. This study has been designed to evaluate the accuracy and precision of body composition prediction equations by various anthropometric measures instead of a whole body DXA scan. Materials and Methods: We identified 143 adult patients underwent DXA evaluation of the whole body. The anthropometric indices were also measured. Datasets were split randomly into two parts. Multiple regression analysis with a backward stepwise elimination procedure was used as the derivation set and then the estimates were compared with the actual measurements from the whole-body scans for a validation set. The SPSS version 20 for Windows software was used in multiple regression and data analysis. Results: Using multiple linear regression analyses, the best equation for predicting the whole-body fat mass (R2 = 0.808) included the body mass index (BMI) and gender; the best equation for predicting whole-body lean mass (R2 = 0.780) included BMI, WC, gender, and age; and the best equation for predicting trunk fat mass (R2 = 0.759) included BMI, WC, and gender. Conclusions: Combinations of anthropometric measurements predict whole-body lean mass and trunk fat mass better than any of these single anthropometric indices. Therefore, the findings of the present study may be used to verify the results in patients with various diseases or diets. PMID:25709999

  18. Comparison of regional fat mass measurement by whole body DXA scans and anthropometric measures to predict insulin resistance in women with polycystic ovary syndrome and controls

    DEFF Research Database (Denmark)

    Glintborg, Dorte; Houborg Petersen, Maria; Ravn, Pernille

    2016-01-01

    INTRODUCTION: Polycystic ovary syndrome (PCOS) is characterized by obesity and insulin resistance. Measures of regional obesity may be used to predict insulin resistance. In the present study we compared fat distribution in patients with PCOS vs. controls and established the best measure of fat...

  19. Best single-slice location to measure visceral adipose tissue on paediatric CT scans and the relationship between anthropometric measurements, gender and VAT volume in children.

    Science.gov (United States)

    O'Connor, Michelle; Ryan, John; Foley, Shane

    2015-10-01

    Visceral adipose tissue (VAT) is a significant risk factor for obesity-related metabolic diseases. This study investigates (1) the best single CT slice location for predicting total abdominal VAT volume in paediatrics and (2) the relationship between waist circumference (WC), sagittal diameter (SD), gender and VAT volume. A random sample of 130 paediatric abdomen CT scans, stratified according to age and gender, was collected. Three readers measured VAT area at each intervertebral level between T12 and S1 using ImageJ analysis (National Institute of Health, Bethesda, MD) software by thresholding -190 to -30 HU and manually segmenting VAT. Single-slice VAT measurements were correlated with total VAT volume to identify the most representative slice. WC and SD were measured at L3-L4 and L4-L5 slices, respectively. Regression analysis was used to evaluate WC, SD and gender as VAT volume predictors. Interviewer and intraviewer reliability were excellent (intraclass correlation coefficient = 0.99). Although VAT measured at multiple slices correlated strongly with abdominal VAT, only one slice in females at L2-L3 and two slices in males at L1-L2 and L5-S1 were strongly correlated across all age groups. Linear regression analysis showed that WC was strongly correlated with VAT volume (beta = 0.970, p VAT measurements are highly reproducible. Measurements performed at L2-L3 in females and L1-L2 or L5-S1 in males were most representative of VAT. WC is indicative of VAT. VAT should be measured at L2-L3 in female children and at either L1-L2 or L5-S1 in males. WC is a strong indicator of VAT in children.

  20. The Australian Commonwealth standard of measurement for absorbed radiation dose

    International Nuclear Information System (INIS)

    Sherlock, S.L.

    1990-06-01

    This report documents the absorbed dose standard for photon beams in the range from 1 to 25 MeV. Measurements of absorbed dose in graphite irradiated by a beam of cobalt-60 gamma rays from an Atomic Energy of Canada Limited (AECL) E1 Dorado 6 teletherapy unit are reported. The measurements were performed using a graphite calorimeter, which is the primary standard for absorbed dose. The measurements are used to calibrate a working standard ion chamber in terms of absorbed dose in graphite. Details of the methods, results and correction factors applied are given in Appendices. 13 refs., 6 tabs., 6 figs

  1. COMPARATIVE ANALYSIS OF ANTHROPOMETRIC DIMENSIONS ...

    African Journals Online (AJOL)

    A comparative analysis of the anthropometric body dimensions of the male and female agricultural workers was conducted in South-Eastern Nigeria to ascertain the variations that exist among the body characteristics/dimensions of the male and female agricultural workers in the area. Thirty (30) anthropometric dimensions ...

  2. Ergonomic and Anthropometric Consideration for Library Furniture in an Iranian Public University

    Directory of Open Access Journals (Sweden)

    R Osquei-Zadeh

    2011-12-01

    Full Text Available Background: In our competing educational world, students spend a considerable part of their daily life, studying at library furniture. Not surprisingly, due to lack of proper anthropometric databases, these products have typically been ill fitted for the intended user populations. Objective: To verify the optimum anthropometric match of library furniture within an academic environment, through a combined qualitative and quantitative approach. Methods: 267 (120 female and 147 male students, were subjected to 11 standard anthropometric measurements. In line with the measurements, subjective evaluations were also considered through detailed fitting trials on selected groups of participants. Results: Combinational equations defined the unacceptable furniture dimensions according to elbow and sitting popliteal heights, mainly for smaller and taller divisions of the studied population, which were systematically comparable along with subjective and objective outcomes. In brief, if we classified studied students into “small,” “medium,” and “tall” groups, the design dimensions should be altered by -5.1, -2.2, and +1.6 cm for chair seat height; and by -8.3, -5.4, and +1.1 cm for table height, for each student group, respectively. Conclusion: The furniture size to be used by Iranian students should be changed to fit their anthropometric measures.

  3. Ergonomic and anthropometric consideration for library furniture in an Iranian public university.

    Science.gov (United States)

    Osquei-Zadeh, R; Ghamari, J; Abedi, M; Shiri, H

    2012-01-01

    In our competing educational world, students spend a considerable part of their daily life, studying at library furniture. Not surprisingly, due to lack of proper anthropometric databases, these products have typically been ill fitted for the intended user populations. To verify the optimum anthropometric match of library furniture within an academic environment, through a combined qualitative and quantitative approach. 267 (120 female and 147 male) students, were subjected to 11 standard anthropometric measurements. In line with the measurements, subjective evaluations were also considered through detailed fitting trials on selected groups of participants. Combinational equations defined the unacceptable furniture dimensions according to elbow and sitting popliteal heights, mainly for smaller and taller divisions of the studied population, which were systematically comparable along with subjective and objective outcomes. In brief, if we classified studied students into "small," "medium," and "tall" groups, the design dimensions should be altered by -5.1, -2.2, and +1.6 cm for chair seat height; and by -8.3, -5.4, and +1.1 cm for table height, for each student group, respectively. The furniture size to be used by Iranian students should be changed to fit their anthropometric measures.

  4. Speed during training and anthropometric measures in relation to race performance by male and female open-water ultra-endurance swimmers.

    Science.gov (United States)

    Knechtle, Beat; Baumann, Barbara; Knechtle, Patrizia; Rosemann, Thomas

    2010-10-01

    The relationship of anthropometric and training characteristics with race time were investigated in 39 male and 24 female open-water ultra-endurance swimmers in a 26.4 km open-water ultra-swim, using bi- and multivariate analyses. For the men, body height, Body Mass Index, length of arm, and swimming speed during training were related to race time in the bivariate analysis. For the women, swimming speed during training was associated with performance in the bivariate analysis. In the multivariate analysis for the men, Body Mass Index and swimming speed during training were related to race time.

  5. Temperature standards, what and where: resources for effective temperature measurements

    International Nuclear Information System (INIS)

    Johnston, W.W. Jr.

    1982-01-01

    Many standards have been published to describe devices, methods, and other topics. How they are developed and by whom are briefly described, and an attempt is made to extract most of those relating to temperature measurements. A directory of temperature standards and their sources is provided

  6. Anthropometric characteristics evolution in elite rhythmic gymnasts.

    Science.gov (United States)

    di Cagno, Alessandra; Baldari, Carlo; Battaglia, Claudia; Guidetti, Laura; Piazza, Marina

    2008-01-01

    The aims of this research were to assess anthropometric characteristics of high-level senior and junior rhythmic gymnasts; and was to investigate the changes of anthropometric characteristics over a 4 years period, in different senior and junior groups of the same technical level. Twenty anthropometric variables of 63 participants were collected and body composition and sitting-height-to-stature-ratio measures were calculated. The two-way (gymnast category and time) ANOVA of the anthropometric characteristics showed significant main effect of time period for biacromial and bicristal diameters indicating that the majority of variables had similar values in 2002 and 2006. A significant main effect of category (junior or senior) was present in most the analyzed variables with higher values in senior gymnasts than juniors. The significant category by time interaction for height, weight, limbs' length, and fat-free mass, indicated that some differences between junior and senior gymnasts increased over the 4 yr time period. The training hours per week were significantly higher in seniors, but did not differ over the 4 yr period. The study shows that the criteria, followed for the recruitment of elite gymnasts, in the two different periods considered (2002 and 2006) were almost the same. Moreover, higher differences between seniors and juniors of FFM values in 2006 indicated the more intensive training of the second period for seniors.

  7. Portable radiation instrumentation traceability of standards and measurements

    International Nuclear Information System (INIS)

    Wiserman, A.; Walke, M.

    1995-01-01

    Portable radiation measuring instruments are used to estimate and control doses for workers. Calibration of these instruments must be sufficiently accurate to ensure that administrative and legal dose limits are not likely to be exceeded due to measurement uncertainties. An instrument calibration and management program is established which permits measurements made with an instrument to be traced to a national standard. This paper describes the establishment and maintenance of calibration standards for gamma survey instruments and an instrument management program which achieves traceability of measurement for uniquely identified field instruments. (author)

  8. Measurements and standards for bulk-explosives detection

    International Nuclear Information System (INIS)

    Hudson, Larry; Bateman, Fred; Bergstrom, Paul; Cerra, Frank; Glover, Jack; Minniti, Ronaldo; Seltzer, Stephen; Tosh, Ronald

    2012-01-01

    Recent years have seen a dramatic expansion in the application of radiation and isotopes to security screening. This has been driven primarily by increased incidents involving improvised explosive devices as well as their ease of assembly and leveraged disruption of transportation and commerce. With global expenditures for security-screening systems in the hundreds of billions of dollars, there is a pressing need to develop, apply, and harmonize standards for x-ray and gamma-ray screening systems used to detect explosives and other contraband. The National Institute of Standards and Technology has been facilitating the development of standard measurement tools that can be used to gauge the technical performance (imaging quality) and radiation safety of systems used to screen luggage, persons, vehicles, cargo, and left-behind objects. After a review of this new suite of national standard test methods, test objects, and radiation-measurement protocols, we highlight some of the technical trends that are enhancing the revision of baseline standards. Finally we advocate a more intentional use of technical-performance standards by security stakeholders and outline the advantages this would accrue. - Highlights: ► This work responds to the need for standards for x-ray screening systems used to detect explosives. ► Described are new measurement tools to gage the performance and radiation safety of such systems. ► A more intentional use of technical-performance standards by security stakeholders is argued.

  9. The Australian national standard of measurement for radioactivity

    International Nuclear Information System (INIS)

    Buckman, S.M.

    1992-01-01

    This contribution outlines the activities of the Radiation Standards Group at Ansto which is responsible, under the National Measurement Act 1960, for Australia's national standard of radioactivity measurement. The Group can make absolute measurements of radioactivity using a 4π β-γ coincidence counting system, Solutions standardised by this technique are then used to calibrate a TPA ionisation chamber, this chamber being the national working standard of activity measurement. All of the calibration factors determined for this chamber by direct measurement have been compared internationally through the Bureau International de Poids et Mesures (BIPM). These comparisons were performed either by participating in international intercomparisons organised by the BIPM or by submitting a standardised solution to the Systeme International de Reference. 11 refs

  10. Standard test method for conducting potentiodynamic polarization resistance measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers an experimental procedure for polarization resistance measurements which can be used for the calibration of equipment and verification of experimental technique. The test method can provide reproducible corrosion potentials and potentiodynamic polarization resistance measurements. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Ethnic differences in anthropometric and lifestyle measures related to coronary heart disease risk between South Asian, Italian and general-population British women living in the west of Scotland.

    Science.gov (United States)

    Lean, M E; Han, T S; Bush, H; Anderson, A S; Bradby, H; Williams, R

    2001-12-01

    To compare anthropometric measurements and to define their behavioural associations in migrant and British-born South Asians (who have increased cardiovascular risk) or Italians (who have reduced cardiovascular risk), and in the general population of British women living in the west of Scotland. Cross-sectional survey of women aged 20-42 y, selected mainly from birth registration data, which included 63 migrant South Asians, 56 British-born South Asians, 39 migrant Italians, 51 British-born Italians, and 50 subjects representative of the general population of women, all resident in the west of Scotland. Height, weight, body mass index (BMI), and waist and hip circumferences. With age adjustment, migrant South Asians (0.88) had greater waist-to-hip ratio than British-born South Asians (0.84; P<0.05), while there was no difference between migrant (0.81) and British-born (0.79) Italian groups. Both migrant (P<0.001) and British-born South Asian (P<0.05) groups had higher waist-to-hip ratio and were about 3 cm shorter than Italian groups and the general population. Neither weight nor BMI were different between ethnic groups. Waist and hip circumferences were not different between migrant and British-born ethnic minority groups. Migrant South Asians (86.8 cm) had significantly (P<0.05) larger waist circumference than the general population (78.6 cm). British-born Italian women (103.0 cm) had larger hip circumference than the general population of women (96.4 cm), while other groups had similar hip circumferences. Additional adjustments for physical activity, smoking, alcohol consumption and parity reduced the differences in anthropometric measurements: only waist-to-hip ratio of migrant South Asians remained significantly (P<0.01) higher than that of the general population women. The adverse anthropometric indicators of cardiovascular risk in migrant South Asian women are substantially explained by their lifestyle factors and parity. British-born South Asian women are

  12. Women's dietary diversity scores and childhood anthropometric measurements as indices of nutrition insecurity along the urban–rural continuum in Ouagadougou, Burkina Faso

    Directory of Open Access Journals (Sweden)

    Takemore Chagomoka

    2016-02-01

    Full Text Available Background: Malnutrition is still prevalent worldwide, and its severity, which differs between regions and countries, has led to international organisations proposing its inclusion in the global development framework that will succeed the Millennium Development Goals (post-2015 framework. In Sub-Saharan Africa, malnutrition is particularly severe, among women and children under 5 years. The prevalence of malnutrition has been reported worldwide, differing from region to region and country to country. Nevertheless, little is known about how malnutrition differs between multiple locations along an urban–rural continuum. Objective: A survey was carried out in and around Ouagadougou, Burkina Faso, between August and September 2014 to map household nutrition insecurity along the urban–rural continuum, using a transect approach to guide the data collection. Design: Transects of 70 km long and 2 km wide directed radially from the city centre outwards were laid, and data were collected from randomly selected households along these transects. Women's dietary diversity scores (WDDSs were calculated from a sample of 179 women of reproductive age (15–49 years from randomly selected households. Additionally, anthropometric data (height/length and weight of 133 children under 5 years of age were collected along the same transects for the computation of anthropometric indices. Results: We found that relative proportions of the nutrition indices such as stunting, wasting and underweight varied across the urban–rural continuum. Rural households (15% had the highest relative proportion of WDDS compared with urban households (11% and periurban households (8%. There was a significant association between children under 5 years’ nutritional status (wasting, stunting and underweight and spatial location (p=0.023. The level of agricultural activities is a possible indicator of wasting in children aged 6–59 months (p=0.032. Conclusion: Childhood

  13. Anthropometrically-Based Surgical Technique for Tessier 3 Cleft Reconstruction.

    Science.gov (United States)

    Morgan, Aaron L; Cason, Roger; El Amm, Christian A

    2016-11-01

    Craniofacial clefts are rare entities, with an incidence reported as 1.43 to 4.85 per 100,000 births. The Tessier number 3 cleft, the most medial of the oblique clefts, can manifest as clefting of the lip between the canine and lateral incisors, colobomas of the nasal ala and lower eyelid, and inferior displacement of the medial canthus-frequently disrupting the lacrimal system with extreme variability in expressivity (Eppley).Literature on cleft lip repair is extensive and has evolved to incorporate anthropometric techniques, based on identifiable landmarks and anthropometric measurements that are compared with contralateral unaffected anatomy or population means and tracked over time to assess impact on growth. Recent focus has been placed on "subunit" repair that repairs "like with like." These approaches have resulted in a remarkable reproducibility of methods and outcomes.Facial cleft surgery publications are sparse due to the rarity of the disorders, and consensus has yet to develop on standardized landmarks, reference measurements, and principles of repair. The authors describe a method of correcting incomplete unilateral Tessier 3 cleft based on the principles described above. Intraoperative photographs, including secondary revisions, as well as immediate and long-term postoperative results are presented.

  14. Quantum-enhanced measurements: beating the standard quantum limit.

    Science.gov (United States)

    Giovannetti, Vittorio; Lloyd, Seth; Maccone, Lorenzo

    2004-11-19

    Quantum mechanics, through the Heisenberg uncertainty principle, imposes limits on the precision of measurement. Conventional measurement techniques typically fail to reach these limits. Conventional bounds to the precision of measurements such as the shot noise limit or the standard quantum limit are not as fundamental as the Heisenberg limits and can be beaten using quantum strategies that employ "quantum tricks" such as squeezing and entanglement.

  15. High-Sensitive C-Reactive Protein Levels in a Group of Syrian University Male Students and Its Associations with Smoking, Physical Activity, Anthropometric Measurements, and Some Hematologic Inflammation Biomarkers

    Directory of Open Access Journals (Sweden)

    Wafika Zarzour

    2017-01-01

    Full Text Available In Syria, health risk data on young males are limited. Hence, the aim of the present study was to evaluate cardiovascular disease (CVD risk factors along with C-reactive protein levels measured by high-sensitive method (hsCRP in a group of healthy males of university students (n=101, 18–25 years old. Participants’ anthropometric characteristics; alcohol drinking, smoking, and physical activity habits; parents medical history; and some inflammatory biomarkers were inspected for their associations with hsCRP. Results. Regarding hsCRP level, 19 participants were at average (1–3 mg/L and 13 were at high (>3 mg/L risk of CVD. Nonparametric statistical tests (p value < 0.05 revealed that hsCRP level was higher in participants who had high body mass index (BMI, had high BMI with high waist-to-hip ratio (WHR, or did not practice sport frequently. Unexpectedly, it did not vary between smokers and nonsmokers. In general, it correlated positively with anthropometric and erythrocyte sedimentation rate (ESR measurements. Nevertheless, it negatively correlated with sports practicing in overall and nonsmoker groups and in participants whose parents were without medical history. Finally, when participants with high BMI were smokers, did not practice sport frequently, or had a parent with medical history, their hsCRP levels were higher than others who had the same circumstances but with low BMI.

  16. The relative age effect on anthropometric characteristics and motor performances in Turkish children aged between 8 and 12 years

    Directory of Open Access Journals (Sweden)

    Haslofça Ercan

    2016-01-01

    Full Text Available This study was carried out to investigate the effect of relative age on anthropometric properties and motor performance in Turkish children (girls n=423, boys n=601. Anthropometric measurement sites and techniques have been set out by the ISAK (International Society for the Advancement of Kinanthropometry. A group of tests involved in Eurofit Test Battery and other standard tests were used. For each age, the data of those who were born within the first three months and the last three months of the year were compared. The MedCalc Statistics Program was used for the differentiation and variation percentages between two periods were studied (p≤ 0.001, p= 0.05. Consequently effect of relative age was observed on anthropometric characteristics and motor performances of Turkish girls and boys between 8 and 12 years old. Researchers, trainers, families, sports managers and organizers are advised to consider Effect of Relative Age.

  17. Standard Test Method for Measured Speed of Oil Diffusion Pumps

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the determination of the measured speed (volumetric flow rate) of oil diffusion pumps. 1.2 The values stated in inch-pound units are to be regarded as the standard. The metric equivalents of inch-pound units may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Standard cartridges used in gamma spectrometry measurements of radioactive halogens

    International Nuclear Information System (INIS)

    Lepy, M.C.; Etcheverry, M.; Morel, J.; Chauvenet, B.

    1988-10-01

    Activated charcoal cartridges are used to trap radioactive halogens contained in gaseous effluents of nuclear facilities. Two types of standard cartridges, with barium 133 or europium 152 are available. One of the models simulates a volumic distribution, and the other a surface distribution of the radionuclides inside the cartridge. They are characterized in terms of activity with an uncertainty lower than 5 %. The standard cartridges utilization conditions are specified and the main measurement error causes are analyzed. The proper routine use of these standards should allow us to get results with an accuracy better than 10 % [fr

  19. Performance Measurement of Management System Standards Using the Balanced Scorecard

    Directory of Open Access Journals (Sweden)

    Jan Kopia

    2017-11-01

    Full Text Available Management system standards (MSS, such as ISO standards, TQM, etc. are widely-used standards adopted by millions of organizations worldwide. It is still an unclear question whether these standards are beneficial for an organization, besides the fact that they might be required or expected by law or customers. The question, whether MSS increase the efficiency, the output, or the performance of an organization is still discussed in scientific research. One reason might be that performance measurement itself is not fully understood or in constant development ranging from pure financial evaluations over intellectual capital rating to calculating of levels of environmental, social or economic expectations known as the Trible Bottom Line. The Balanced Scorecard is one possible solution for performance measurement on a strategic and operational level and therefore useful for the measurement of the influence of MSS within organizations. This study summarized current research in the field of performance measurement in the context of MSS and IMS and the use of BSC and quantitatively and qualitatively tests the usefulness of BSC in measuring the effect of MSSs using the Execution Premium. It was found that BSC is often used, that an average number of companies integrate their measurement initiatives of their MSSs into the BSC-process, and that a high integration of MSS into the BSC improves the organizational performance. This research is useful for researchers and practitioners in order to understand the benefits of the usage of the BSC in the context of MSS or Integrated Management Systems.

  20. Standardized measurement of quality of life after incisional hernia repair

    DEFF Research Database (Denmark)

    Jensen, Kristian K; Henriksen, Nadia A; Harling, Henrik

    2014-01-01

    repair. The aim of this systematic review was to analyze existing standardized methods to measure quality of life after incisional hernia repair. DATA SOURCES: A PubMed and Embase search was carried out together with a cross-reference search of eligible papers, giving a total of 26 included studies......BACKGROUND: Recent improvements in incisional hernia repair have led to lower rates of recurrence. As a consequence, increasing attention has been paid to patient-reported outcomes after surgery. However, there is no consensus on how to measure patients' quality of life after incisional hernia....... CONCLUSIONS: Different standardized methods for measurement of quality of life after incisional hernia repair are available, but no consensus on the optimal method, timing, or length of follow-up exist. International guidelines could help standardization, enabling better comparison between studies....

  1. Possible standard specimens for neutron diffraction residual stress measurements

    International Nuclear Information System (INIS)

    Brand, P.C.; Prask, H.J.; Fields, R.J.; Blackburn, J.; Proctor, T.M.

    1995-01-01

    Increasingly, sub-surface residual stress measurements by means of neutron diffraction are being conducted at various laboratories around the world. Unlike X-ray diffraction residual stress measurement setups, neutron instruments in use worldwide vary widely in design, neutron flux, and level of dedication towards residual stress measurements. Although confidence in the neutron technique has increased within the materials science and engineering communities, no demonstration of standardization or consistency between laboratories has been made. One of the steps in the direction of such standardization is the development of standard specimens, that have well characterized residual stress states and which could be examined worldwide. In this paper the authors will examine two options for a neutron stress standard specimen: (1) a steel ring-plug specimen with very well defined diametrical interference; (2) a spot weld in a High Strength Low Alloy steel disk. The results of neutron residual stress measurements on these specimens will be discussed and conclusions as to their usefulness as neutron stress standards will be presented

  2. Constraining new physics with collider measurements of Standard Model signatures

    Energy Technology Data Exchange (ETDEWEB)

    Butterworth, Jonathan M. [Department of Physics and Astronomy, University College London,Gower St., London, WC1E 6BT (United Kingdom); Grellscheid, David [IPPP, Department of Physics, Durham University,Durham, DH1 3LE (United Kingdom); Krämer, Michael; Sarrazin, Björn [Institute for Theoretical Particle Physics and Cosmology, RWTH Aachen University,Sommerfeldstr. 16, 52056 Aachen (Germany); Yallup, David [Department of Physics and Astronomy, University College London,Gower St., London, WC1E 6BT (United Kingdom)

    2017-03-14

    A new method providing general consistency constraints for Beyond-the-Standard-Model (BSM) theories, using measurements at particle colliders, is presented. The method, ‘Constraints On New Theories Using Rivet’, CONTUR, exploits the fact that particle-level differential measurements made in fiducial regions of phase-space have a high degree of model-independence. These measurements can therefore be compared to BSM physics implemented in Monte Carlo generators in a very generic way, allowing a wider array of final states to be considered than is typically the case. The CONTUR approach should be seen as complementary to the discovery potential of direct searches, being designed to eliminate inconsistent BSM proposals in a context where many (but perhaps not all) measurements are consistent with the Standard Model. We demonstrate, using a competitive simplified dark matter model, the power of this approach. The CONTUR method is highly scaleable to other models and future measurements.

  3. Temperature measurements at the National Institute of Standards and Technology

    Science.gov (United States)

    Mangum, B. W.

    The high-precision and high-accuracy measurements involved in the calibrations of various types of thermometers at the National Institute of Standards and Technology (NIST) are described. The responsibilities of the NIST Thermometry Group include not only calibration of the standard instruments of the scales but also the calibration of base-metal and noble-metal thermocouples, industrial platinum resistance thermometers, liquid in-glass thermometers, thermistor thermometers, and digital thermometers. General laboratory thermometer calibrations are described. Also, a Measurement Assurance Program is described which provides a direct assessment of a customer's technological competence in thermometry.

  4. Overview of the Standard Model Measurements with the ATLAS Detector

    CERN Document Server

    Liu, Yanwen; The ATLAS collaboration

    2017-01-01

    The ATLAS Collaboration is engaged in precision measurement of fundamental Standard Model parameters, such as the W boson mass, the weak-mixing angle or the strong coupling constant. In addition, the production cross-sections of a large variety of final states involving high energetic jets, photons as well as single and multi vector bosons are measured multi differentially at several center of mass energies. This allows to test perturbative QCD calculations to highest precision. In addition, these measurements allow also to test models beyond the SM, e.g. those leading to anomalous gauge couplings. In this talk, we give a broad overview of the Standard Model measurement campaign of the ATLAS collaboration, where selected topics will be discussed in more detail.

  5. ATLAS Standard Model Measurements Using Jet Grooming and Substructure

    CERN Document Server

    Ucchielli, Giulia; The ATLAS collaboration

    2017-01-01

    Boosted topologies allow to explore Standard Model processes in kinematical regimes never tested before. In such LHC challenging environments, standard reconstruction techniques quickly hit the wall. Targeting hadronic final states means to properly reconstruct energy and multiplicity of the jets in the event. In order to be able to identify the decay product of boosted objects, i.e. W bosons, $t\\bar{t}$ pairs or Higgs produced in association with $t\\bar{t}$ pairs, ATLAS experiment is currently exploiting several algorithms using jet grooming and jet substructure. This contribution will mainly cover the following ATLAS measurements: $t\\bar{t}$ differential cross section production and jet mass using the soft drop procedure. Standard Model measurements offer the perfect field to test the performances of new jet tagging techniques which will become even more important in the search for new physics in highly boosted topologies.”

  6. Geographical and temporal changes of anthropometric traits in historical Yemen.

    Science.gov (United States)

    Danubio, Maria Enrica; Milia, Nicola; Coppa, Alfredo; Rufo, Fabrizio; Sanna, Emanuele

    2016-02-01

    This study investigates secular changes of anthropometric variables among four geographic groups in historical Yemen, to evaluate possible regional differences in the evolution of living standards. Nineteen somatic and cephalic measures collected by Coon in 1939, and 8 anthropometric indices in 1244 Yemenite adult males were analyzed. The individuals were divided into 10-year age groups. Within-group variations were tested by One-way ANCOVA (age as covariate). ANCOVA (controlling for age), and Forward stepwise discriminant analysis were used to evaluate and represent regional differences. ANCOVA and discriminant analysis confirmed and enhanced previous findings. At the time, the Yemenite population presented high intergroup heterogeneity. The highest mean values of height at all ages were found in the "mountain" region, which is characterized by very fertile soils and where, nowadays, most of the cereals and pulses are grown and where most livestock is raised. Within-group variations were limited and generally inconsistent in all geographic regions and concern vertical dimensions, but mean values of height never differed. The prolonged internal isolation of these groups resulted in significant regional morphometric differentiation. The main evidence comes from height which suggests that socioeconomic factors have played a role. Nevertheless, the possible better living conditions experienced by the "mountain" group, with the highest mean values of stature in all periods, did not allow the secular trend to take place in that region, too. Copyright © 2015. Published by Elsevier GmbH.

  7. Conditional Standard Errors of Measurement for Scale Scores.

    Science.gov (United States)

    Kolen, Michael J.; And Others

    1992-01-01

    A procedure is described for estimating the reliability and conditional standard errors of measurement of scale scores incorporating the discrete transformation of raw scores to scale scores. The method is illustrated using a strong true score model, and practical applications are described. (SLD)

  8. Vitamin D measurement standardization: The way out of the chaos.

    Science.gov (United States)

    Binkley, N; Dawson-Hughes, B; Durazo-Arvizu, R; Thamm, M; Tian, L; Merkel, J M; Jones, J C; Carter, G D; Sempos, C T

    2017-10-01

    Substantial variability is associated with laboratory measurement of serum total 25-hydroxyvitamin D [25(OH)D]. The resulting chaos impedes development of consensus 25(OH)D values to define stages of vitamin D status. As resolving this situation requires standardized measurement of 25(OH)D, the Vitamin D Standardization Program (VDSP) developed methodology to standardize 25(OH)D measurement to the gold standard reference measurement procedures of NIST, Ghent University and CDC. Importantly, VDSP developed protocols for standardizing 25(OH)D values from prior research based on availability of stored serum samples. The effect of such retrospective standardization on prevalence of "low" vitamin D status in national studies reported here for The Third National Health and Nutrition Examination Survey (NHANES III, 1988-1994) and the German Health Interview and Examination Survey for Children and Adolescents (KIGGS, 2003-2006) was such that in NHANES III 25(OH)D values were lower than original values while higher in KIGGS. In NHANES III the percentage with values below 30, 50 and 75 nmol/L increased from 4% to 6%, 22% to 31% and 55% to 71%, respectively. Whereas in KIGGS after standardization the percentage below 30, 50, and 70 nmol/L decreased from 28% to 13%, 64% to 47% and 87% to 85% respectively. Moreover, in a hypothetical example, depending on whether the 25(OH)D assay was positively or negatively biased by 12%, the 25(OH)D concentration which maximally suppressed PTH could vary from 20 to 35ng/mL. These examples underscore the challenges (perhaps impossibility) of developing vitamin D guidelines using unstandardized 25(OH)D data. Retrospective 25(OH)D standardization can be applied to old studies where stored serum samples exist. As a way forward, we suggest an international effort to identify key prior studies with stored samples for re-analysis and standardization initially to define the 25(OH)D level associated with vitamin D deficiency (rickets

  9. Comparison of anthropometry with photogrammetry based on a standardized clinical photographic technique using a cephalostat and chair.

    Science.gov (United States)

    Han, Kihwan; Kwon, Hyuk Joon; Choi, Tae Hyun; Kim, Jun Hyung; Son, Daegu

    2010-03-01

    The aim of this study was to standardize clinical photogrammetric techniques, and to compare anthropometry with photogrammetry. To standardize clinical photography, we have developed a photographic cephalostat and chair. We investigated the repeatability of the standardized clinical photogrammetric technique. Then, with 40 landmarks, a total of 96 anthropometric measurement items was obtained from 100 Koreans. Ninety six photogrammetric measurements from the same subjects were also obtained from standardized clinical photographs using Adobe Photoshop version 7.0 (Adobe Systems Corporation, San Jose, CA, USA). The photogrammetric and anthropometric measurement data (mm, degree) were then compared. A coefficient was obtained by dividing the anthropometric measurements by the photogrammetric measurements. The repeatability of the standardized photography was statistically significantly high (p=0.463). Among the 96 measurement items, 44 items were reliable; for these items the photogrammetric measurements were not different to the anthropometric measurements. The remaining 52 items must be classified as unreliable. By developing a photographic cephalostat and chair, we have standardized clinical photogrammetric techniques. The reliable set of measurement items can be used as anthropometric measurements. For unreliable measurement items, applying a suitable coefficient to the photogrammetric measurement allows the anthropometric measurement to be obtained indirectly.

  10. Influence of Single-Nucleotide Polymorphisms in PPAR-δ, PPAR-γ, and PRKAA2 on the Changes in Anthropometric Indices and Blood Measurements through Exercise-Centered Lifestyle Intervention in Japanese Middle-Aged Men

    Directory of Open Access Journals (Sweden)

    Yuichiro Nishida

    2018-03-01

    Full Text Available The purpose of the current study was to examine the influence of single-nucleotide polymorphisms (SNPs in the peroxisome proliferator-activated receptor-δ (PPAR-δ, PPAR-γ, and α2 isoforms of the catalytic subunit of AMP-activated protein kinase (PRKAA2 on the extent of changes in anthropometric indices and blood measurements through exercise-centered lifestyle intervention in middle-aged men. A total of 109 Japanese middle-aged male subjects (47.0 ± 0.4 years participated in the baseline health checkup, 6-month exercise-centered lifestyle intervention, and second checkup conducted several months after the subject completed the intervention. The body mass index (BMI, waist circumference, and clinical measurements, including hemoglobin Alc (HbA1c, triglyceride (TG, alanine aminotransferase (ALT, and γ-glutamyl-transpeptidase (γ-GTP, were measured at the baseline and second checkup. The three SNPs of PPAR-δ A/G (rs2267668, PPAR-γ C/G (rs1801282, and PRKAA2 A/G (rs1418442 were determined. Blunted responses in the reduction in the BMI and waist circumference were observed in A/A carriers of PPAR-δ SNP compared with G allele carriers (all p < 0.05. The A/A carriers also displayed less-marked improvements in HbA1c, TG, ALT, and γ-GTP (all p < 0.05. The current results suggest that A/A carriers of PPAR-δ SNP (rs2267668 may enjoy fewer beneficial effects of exercise-centered lifestyle intervention on anthropometric indices and blood measurements.

  11. Applying OGC Standards to Develop a Land Surveying Measurement Model

    Directory of Open Access Journals (Sweden)

    Ioannis Sofos

    2017-02-01

    Full Text Available The Open Geospatial Consortium (OGC is committed to developing quality open standards for the global geospatial community, thus enhancing the interoperability of geographic information. In the domain of sensor networks, the Sensor Web Enablement (SWE initiative has been developed to define the necessary context by introducing modeling standards, like ‘Observation & Measurement’ (O&M and services to provide interaction like ‘Sensor Observation Service’ (SOS. Land surveying measurements on the other hand comprise a domain where observation information structures and services have not been aligned to the OGC observation model. In this paper, an OGC-compatible, aligned to the ‘Observation and Measurements’ standard, model for land surveying observations has been developed and discussed. Furthermore, a case study instantiates the above model, and an SOS implementation has been developed based on the 52° North SOS platform. Finally, a visualization schema is used to produce ‘Web Map Service (WMS’ observation maps. Even though there are elements that differentiate this work from classic ‘O&M’ modeling cases, the proposed model and flows are developed in order to provide the benefits of standardizing land surveying measurement data (cost reducing by reusability, higher precision level, data fusion of multiple sources, raw observation spatiotemporal repository access, development of Measurement-Based GIS (MBGIS to the geoinformation community.

  12. Evaluating a standardized measure of healthcare personnel influenza vaccination.

    Science.gov (United States)

    Lindley, Megan C; Lorick, Suchita A; Geevarughese, Anita; Lee, Soo-Jeong; Makvandi, Monear; Miller, Brady L; Nace, David A; Smith, Carmela; Ahmed, Faruque

    2013-09-01

    Methods of measuring influenza vaccination of healthcare personnel (HCP) vary substantially, as do the groups of HCP that are included in any given set of measurements. Thus, comparison of vaccination rates across healthcare facilities is difficult. The goal of the study was to determine the feasibility of implementing a standardized measure for reporting HCP influenza vaccination data in various types of healthcare facilities. A total of 318 facilities recruited in four U.S. jurisdictions agreed to participate in the evaluation, including hospitals, long-term care facilities, dialysis clinics, ambulatory surgery centers, and physician practices. HCP in participating facilities were categorized as employees, credentialed non-employees, or other non-employees using standard definitions. Data were gathered using cross-sectional web-based surveys completed at three intervals between October 2010 and May 2011; data were analyzed in February 2012. 234 facilities (74%) completed all three surveys. Most facilities could report on-site employee vaccination; almost one third could not provide complete data on HCP vaccinated outside the facility, contraindications, or declinations, primarily due to missing non-employee data. Inability to determine vaccination status of credentialed and other non-employees was cited as a major barrier to measure implementation by 24% and 27% of respondents, respectively. Using the measure to report employee vaccination status was feasible for most facilities; tracking non-employee HCP was more challenging. Based on evaluation findings, the measure was revised to limit the types of non-employees included. Although the revised measure is less comprehensive, it is more likely to produce valid vaccination coverage estimates. Use of this standardized measure can inform quality improvement efforts and facilitate comparison of HCP influenza vaccination among facilities. Published by Elsevier Inc.

  13. Standard guide for use of modeling for passive gamma measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide addresses the use of models with passive gamma-ray measurement systems. Mathematical models based on physical principles can be used to assist in calibration of gamma-ray measurement systems and in analysis of measurement data. Some nondestructive assay (NDA) measurement programs involve the assay of a wide variety of item geometries and matrix combinations for which the development of physical standards are not practical. In these situations, modeling may provide a cost-effective means of meeting user’s data quality objectives. 1.2 A scientific knowledge of radiation sources and detectors, calibration procedures, geometry and error analysis is needed for users of this standard. This guide assumes that the user has, at a minimum, a basic understanding of these principles and good NDA practices (see Guide C1592), as defined for an NDA professional in Guide C1490. The user of this standard must have at least a basic understanding of the software used for modeling. Instructions or further train...

  14. Standardization of Solar Mirror Reflectance Measurements - Round Robin Test: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Meyen, S.; Lupfert, E.; Fernandez-Garcia, A.; Kennedy, C.

    2010-10-01

    Within the SolarPaces Task III standardization activities, DLR, CIEMAT, and NREL have concentrated on optimizing the procedure to measure the reflectance of solar mirrors. From this work, the laboratories have developed a clear definition of the method and requirements needed of commercial instruments for reliable reflectance results. A round robin test was performed between the three laboratories with samples that represent all of the commercial solar mirrors currently available for concentrating solar power (CSP) applications. The results show surprisingly large differences in hemispherical reflectance (sh) of 0.007 and specular reflectance (ss) of 0.004 between the laboratories. These differences indicate the importance of minimum instrument requirements and standardized procedures. Based on these results, the optimal procedure will be formulated and validated with a new round robin test in which a better accuracy is expected. Improved instruments and reference standards are needed to reach the necessary accuracy for cost and efficiency calculations.

  15. Computer-based anthropometrical system for total body irradiation.

    Science.gov (United States)

    Sánchez-Nieto, B; Sánchez-Doblado, F; Terrón, J A; Arráns, R; Errazquin, L

    1997-05-01

    For total body irradiation (TBI) dose calculation requirements, anatomical information about the whole body is needed. Despite the fact that video image grabbing techniques are used by some treatment planning systems for standard radiotherapy, there are no such systems designed to generate anatomical parameters for TBI planning. The paper describes an anthropometrical computerised system based on video image grabbing which was purpose-built to provide anatomical data for a PC-based TBI planning system. Using software, the system controls the acquisition and digitalisation of the images (external images of the patient in treatment position) and the measurement procedure itself (on the external images or the digital CT information). An ASCII file, readable by the TBI planning system, is generated to store the required parameters of the dose calculation points, i.e. depth, backscatter tissue thickness, thickness of inhomogeneity, off-axis distance (OAD) and source to skin distance (SSD).

  16. Experience with local lymph node assay performance standards using standard radioactivity and nonradioactive cell count measurements.

    Science.gov (United States)

    Basketter, David; Kolle, Susanne N; Schrage, Arnhild; Honarvar, Naveed; Gamer, Armin O; van Ravenzwaay, Bennard; Landsiedel, Robert

    2012-08-01

    The local lymph node assay (LLNA) is the preferred test for identification of skin-sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. To facilitate acceptance of nonradioactive variants, validation authorities have published harmonized minimum performance standards (PS) that the alternative endpoint assay must meet. In the present work, these standards were applied to a variant of the LLNA based on lymph node cell counts (LNCC) run in parallel as a control with the standard LLNA with radioactivity measurements, with threshold concentrations (EC3) being determined for the sensitizers. Of the 22 PS chemicals tested in this study, 21 yielded the same results from standard radioactivity and cell count measurements; only 2-mercaptobenzothiazole was positive by LLNA but negative by LNCC. Of the 16 PS positives, 15 were positive by LLNA and 14 by LNCC; methylmethacrylate was not identified as sensitizer by either of the measurements. Two of the six PS negatives tested negative in our study by both LLNA and LNCC. Of the four PS negatives which were positive in our study, chlorobenzene and methyl salicylate were tested at higher concentrations than the published PS, whereas the corresponding concentrations resulted in consistent negative results. Methylmethacrylate and nickel chloride tested positive within the concentration range used for the published PS. The results indicate cell counts and radioactive measurements are in good accordance within the same LLNA using the 22 PS test substances. Comparisons with the published PS results may, however, require balanced analysis rather than a simple checklist approach. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Weight Measurements and Standards for Soldiers, Phase 2

    Science.gov (United States)

    2016-10-01

    includes personalized eating , fitness, and APFT tools to help Soldiers stay fit and meet AR600-9 and APFT standards, and 2) a promotion program designed...Pennington Biomedical Research Center (PBRC) is delivering a program to the Louisiana Army National Guard (LANG) called Healthy Eating , Activity, and...and the Army Physical Fitness Test (APFT) (3), i.e., height, weight, fatness estimates, and measures of fitness, 2) assess the unique health risk

  18. Estimating Wet Bulb Globe Temperature Using Standard Meteorological Measurements

    International Nuclear Information System (INIS)

    Hunter, C.H.

    1999-01-01

    The heat stress management program at the Department of Energy''s Savannah River Site (SRS) requires implementation of protective controls on outdoor work based on observed values of wet bulb globe temperature (WBGT). To ensure continued compliance with heat stress program requirements, a computer algorithm was developed which calculates an estimate of WBGT using standard meteorological measurements. In addition, scripts were developed to generate a calculation every 15 minutes and post the results to an Intranet web site

  19. International standards for phytosanitary measures (ISPM), publication No. 15

    CERN Multimedia

    Tom Wegelius

    2006-01-01

    GUIDELINES FOR REGULATING WOOD PACKAGING MATERIAL IN INTERNATIONAL TRADE SCOPE This standard describes phytosanitary measures to reduce the risk of introduction and/or spread of quarantine pests associated with wood packaging material (including dunnage), made of coniferous and non-coniferous raw wood, in use in international trade. For more information, contact the Shipping Service (FI-LS-SH) at 79947. Table of guidelines

  20. Research standardization tools: pregnancy measures in the PhenX Toolkit.

    Science.gov (United States)

    Malinowski, Ann Kinga; Ananth, Cande V; Catalano, Patrick; Hines, Erin P; Kirby, Russell S; Klebanoff, Mark A; Mulvihill, John J; Simhan, Hyagriv; Hamilton, Carol M; Hendershot, Tabitha P; Phillips, Michael J; Kilpatrick, Lisa A; Maiese, Deborah R; Ramos, Erin M; Wright, Rosalind J; Dolan, Siobhan M

    2017-09-01

    Only through concerted and well-executed research endeavors can we gain the requisite knowledge to advance pregnancy care and have a positive impact on maternal and newborn health. Yet the heterogeneity inherent in individual studies limits our ability to compare and synthesize study results, thus impeding the capacity to draw meaningful conclusions that can be trusted to inform clinical care. The PhenX Toolkit (http://www.phenxtoolkit.org), supported since 2007 by the National Institutes of Health, is a web-based catalog of standardized protocols for measuring phenotypes and exposures relevant for clinical research. In 2016, a working group of pregnancy experts recommended 15 measures for the PhenX Toolkit that are highly relevant to pregnancy research. The working group followed the established PhenX consensus process to recommend protocols that are broadly validated, well established, nonproprietary, and have a relatively low burden for investigators and participants. The working group considered input from the pregnancy experts and the broader research community and included measures addressing the mode of conception, gestational age, fetal growth assessment, prenatal care, the mode of delivery, gestational diabetes, behavioral and mental health, and environmental exposure biomarkers. These pregnancy measures complement the existing measures for other established domains in the PhenX Toolkit, including reproductive health, anthropometrics, demographic characteristics, and alcohol, tobacco, and other substances. The preceding domains influence a woman's health during pregnancy. For each measure, the PhenX Toolkit includes data dictionaries and data collection worksheets that facilitate incorporation of the protocol into new or existing studies. The measures within the pregnancy domain offer a valuable resource to investigators and clinicians and are well poised to facilitate collaborative pregnancy research with the goal to improve patient care. To achieve this

  1. Development of measurement standards for verifying functional performance of surface texture measuring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, A [Life and Industrial Product Development Department Olympus Corporation, 2951 Ishikawa-machi, Hachiouji-shi, Tokyo (Japan); Suzuki, H [Industrial Marketing and Planning Department Olympus Corporation, Shinjyuku Monolith, 3-1 Nishi-Shinjyuku 2-chome, Tokyo (Japan); Yanagi, K, E-mail: a_fujii@ot.olympus.co.jp [Department of Mechanical Engineering, Nagaoka University of Technology, 1603-1 Kamitomioka-machi, Nagaoka-shi, Niigata (Japan)

    2011-08-19

    A new measurement standard is proposed for verifying overall functional performance of surface texture measuring instruments. Its surface is composed of sinusoidal surface waveforms of chirp signals along horizontal cross sections of the material measure. One of the notable features is that the amplitude of each cycle in the chirp signal form is geometrically modulated so that the maximum slope is kept constant. The maximum slope of the chirp-like signal is gradually decreased according to movement in the lateral direction. We fabricated the measurement standard by FIB processing, and it was calibrated by AFM. We tried to evaluate the functional performance of Laser Scanning Microscope by this standard in terms of amplitude response with varying slope angles. As a result, it was concluded that the proposed standard can easily evaluate the performance of surface texture measuring instruments.

  2. A spectroscopic transfer standard for accurate atmospheric CO measurements

    Science.gov (United States)

    Nwaboh, Javis A.; Li, Gang; Serdyukov, Anton; Werhahn, Olav; Ebert, Volker

    2016-04-01

    Atmospheric carbon monoxide (CO) is a precursor of essential climate variables and has an indirect effect for enhancing global warming. Accurate and reliable measurements of atmospheric CO concentration are becoming indispensable. WMO-GAW reports states a compatibility goal of ±2 ppb for atmospheric CO concentration measurements. Therefore, the EMRP-HIGHGAS (European metrology research program - high-impact greenhouse gases) project aims at developing spectroscopic transfer standards for CO concentration measurements to meet this goal. A spectroscopic transfer standard would provide results that are directly traceable to the SI, can be very useful for calibration of devices operating in the field, and could complement classical gas standards in the field where calibration gas mixtures in bottles often are not accurate, available or stable enough [1][2]. Here, we present our new direct tunable diode laser absorption spectroscopy (dTDLAS) sensor capable of performing absolute ("calibration free") CO concentration measurements, and being operated as a spectroscopic transfer standard. To achieve the compatibility goal stated by WMO for CO concentration measurements and ensure the traceability of the final concentration results, traceable spectral line data especially line intensities with appropriate uncertainties are needed. Therefore, we utilize our new high-resolution Fourier-transform infrared (FTIR) spectroscopy CO line data for the 2-0 band, with significantly reduced uncertainties, for the dTDLAS data evaluation. Further, we demonstrate the capability of our sensor for atmospheric CO measurements, discuss uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) principles and show that CO concentrations derived using the sensor, based on the TILSAM (traceable infrared laser spectroscopic amount fraction measurement) method, are in excellent agreement with gravimetric values. Acknowledgement Parts of this work have been

  3. Relationship between insulin resistance-associated metabolic parameters and anthropometric measurements with sugar-sweetened beverage intake and physical activity levels in US adolescents: findings from the 1999-2004 National Health and Nutrition Examination Survey.

    Science.gov (United States)

    Bremer, Andrew A; Auinger, Peggy; Byrd, Robert S

    2009-04-01

    To evaluate the relationship between insulin resistance-associated metabolic parameters and anthropometric measurements with sugar-sweetened beverage intake and physical activity levels. A cross-sectional analysis of the National Health and Nutrition Examination Survey data collected by the National Center for Health Statistics. Nationally representative samples of US adolescents participating in the National Health and Nutrition Examination Survey during the years 1999-2004. A total of 6967 adolescents aged 12 to 19 years. Sugar-sweetened beverage consumption and physical activity levels. Glucose and insulin concentrations, a homeostasis model assessment of insulin resistance (HOMA-IR), total, high-density lipoprotein, and low-density lipoprotein cholesterol concentrations, triglyceride concentrations, systolic and diastolic blood pressure, waist circumference, and body mass index (calculated as weight in kilograms divided by height in meters squared) percentile for age and sex. Multivariate linear regression analyses showed that increased sugar-sweetened beverage intake was independently associated with increased HOMA-IR, systolic blood pressure, waist circumference, and body mass index percentile for age and sex and decreased HDL cholesterol concentrations; alternatively, increased physical activity levels were independently associated with decreased HOMA-IR, low-density lipoprotein cholesterol concentrations, and triglyceride concentrations and increased high-density lipoprotein cholesterol concentrations. Furthermore, low sugar-sweetened beverage intake and high physical activity levels appear to modify each others' effects of decreasing HOMA-IR and triglyceride concentrations and increasing high-density lipoprotein cholesterol concentrations. Sugar-sweetened beverage intake and physical activity levels are each independently associated with insulin resistance-associated metabolic parameters and anthropometric measurements in adolescents. Moreover, low sugar

  4. Spectroscopic metrology for isotope composition measurements and transfer standards

    Science.gov (United States)

    Anyangwe Nwaboh, Javis; Balslev-Harder, David; Kääriäinen, Teemu; Richmond, Craig; Manninen, Albert; Mohn, Joachim; Kiseleva, Maria; Petersen, Jan C.; Werhahn, Olav; Ebert, Volker

    2017-04-01

    The World Meteorological Organization (WMO) has identified greenhouse gases such as CO2, CH4 and N2O as critical for global climate monitoring. Other molecules such as CO that has an indirect effect of enhancing global warming are also monitored. WMO has stated compatibility goals for atmospheric concentration and isotope ratio measurements of these gases, e.g. 0.1 ppm for CO2 concentration measurements in the northern hemisphere and 0.01 ‰ for δ13C-CO2. For measurements of the concentration of greenhouse gases, gas analysers are typically calibrated with static gas standards e.g. traceable to the WMO scale or to the International System of Units (SI) through a national metrology institute. However, concentrations of target components, e.g. CO, in static gas standards have been observed to drift, and typically the gas matrix as well as the isotopic composition of the target component does not always reflect field gas composition, leading to deviations of the analyser response, even after calibration. The deviations are dependent on the measurement technique. To address this issue, part of the HIGHGAS (Metrology for high-impact greenhouse gases) project [1] focused on the development of optical transfer standards (OTSs) for greenhouse gases, e.g. CO2 and CO, potentially complementing gas standards. Isotope ratio mass spectrometry (IRMS) [2] is currently used to provide state-of-the-art high precision (in the 0.01 ‰ range) measurements for the isotopic composition of greenhouse gases. However, there is a need for field-deployable techniques such as optical isotope ratio spectroscopy (OIRS) that can be combined with metrological measurement methods. Within the HIGHGAS project, OIRS methods and procedures based on e.g. cavity enhanced spectroscopy (CES) and tunable diode laser absorption spectroscopy (TDLAS), matched to metrological principles have been established for the measurement of 13C/12C and 18O/16O ratios in CO2, 15N/14N ratios in N2O, and 13C/12C and 2H

  5. Relationship between anthropometric and haematological ...

    African Journals Online (AJOL)

    olayemitoyin

    healthy, singleton, third trimester pregnant women attending ANC at the State Specialist Hospital and 58 apparently healthy ... boost self sufficiency for better weight gains and to facilitate access to good healthcare so that the ideal anthropometric and .... graduation is 1mm, dimensions of 328 x 21485 x. 574mm. Body Mass ...

  6. Physiological and anthropometric determinants of rhythmic gymnastics performance.

    Science.gov (United States)

    Douda, Helen T; Toubekis, Argyris G; Avloniti, Alexandra A; Tokmakidis, Savvas P

    2008-03-01

    To identify the physiological and anthropometric predictors of rhythmic gymnastics performance, which was defined from the total ranking score of each athlete in a national competition. Thirty-four rhythmic gymnasts were divided into 2 groups, elite (n = 15) and nonelite (n = 19), and they underwent a battery of anthropometric, physical fitness, and physiological measurements. The principal-components analysis extracted 6 components: anthropometric, flexibility, explosive strength, aerobic capacity, body dimensions, and anaerobic metabolism. These were used in a simultaneous multiple-regression procedure to determine which best explain the variance in rhythmic gymnastics performance. Based on the principal-component analysis, the anthropometric component explained 45% of the total variance, flexibility 12.1%, explosive strength 9.2%, aerobic capacity 7.4%, body dimensions 6.8%, and anaerobic metabolism 4.6%. Components of anthropometric (r = .50) and aerobic capacity (r = .49) were significantly correlated with performance (P gymnasts, 92.5% of the variation was explained by VO2max (58.9%), arm span (12%), midthigh circumference (13.1%), and body mass (8.5%). Selected anthropometric characteristics, aerobic power, flexibility, and explosive strength are important determinants of successful performance. These findings might have practical implications for both training and talent identification in rhythmic gymnastics.

  7. Novel design of a usable and accurate anthropometric caliper.

    Science.gov (United States)

    Osquei-Zadeh, R; Rousta-Nezhad, M

    2012-07-01

    Anthropometric kits are extensively used in workstation and product design projects, and with the advancement of technology, they have turned into highly complex and effective instruments. However, there are still many challenging problems in usability and reliability of application of these kits in real-world settings. To identify the usability and accuracy issues with a conventional anthropometric caliper, and to propose measurable design features to enhance the functionality of the caliper. The measurement process using a conventional anthropometric caliper was systematically analyzed through detailed hierarchical task analyses. Also, six qualified anthropometry specialists performed heuristic evaluations to gain valuable insights into major usability issues in relation to the existing body measurement devices. Based on the resulting concepts, a mock-up was developed and evaluated against the desired specifications. Incorrect positioning angle of the caliper, as well as applying various amounts of force by different investigators to push the caliper branches against body parts, appeared to be the main factors introducing inaccuracy to anthropometric data. Installing a spirit level on caliper, and also a pre-programmed microprocessor for real-time saving of the obtained data, facilitated the measurement process for both investigators and subjects. Accuracy, followed by usability is the primary concern in designing anthropometric instruments. However, expectations would vary from one specialist to another. Therefore, trade-offs should be made when incorporating innovative features in novel designed body measurement kits.

  8. Characterization of textile electrodes and conductors using standardized measurement setups

    International Nuclear Information System (INIS)

    Beckmann, L; Neuhaus, C; Medrano, G; Walter, M; Leonhardt, S; Jungbecker, N; Gries, T

    2010-01-01

    Textile electrodes and conductors are being developed and used in different monitoring scenarios, such as ECG or bioimpedance spectroscopy measurements. Compared to standard materials, conductive textile materials offer improved wearing comfort and enable long-term measurements. Unfortunately, the development and investigation of such materials often suffers from the non-reproducibility of the test scenarios. For example, the materials are generally tested on human skin which is difficult since the properties of human skin differ for each person and can change within hours. This study presents two test setups which offer reproducible measurement procedures for the systematic analysis of textile electrodes and conductors. The electrode test setup was designed with a special skin dummy which allows investigation of not only the electrical properties of textile electrodes but also the contact behavior between electrode and skin. Using both test setups, eight textile electrodes and five textile conductors were analyzed and compared

  9. Characterization of textile electrodes and conductors using standardized measurement setups.

    Science.gov (United States)

    Beckmann, L; Neuhaus, C; Medrano, G; Jungbecker, N; Walter, M; Gries, T; Leonhardt, S

    2010-02-01

    Textile electrodes and conductors are being developed and used in different monitoring scenarios, such as ECG or bioimpedance spectroscopy measurements. Compared to standard materials, conductive textile materials offer improved wearing comfort and enable long-term measurements. Unfortunately, the development and investigation of such materials often suffers from the non-reproducibility of the test scenarios. For example, the materials are generally tested on human skin which is difficult since the properties of human skin differ for each person and can change within hours. This study presents two test setups which offer reproducible measurement procedures for the systematic analysis of textile electrodes and conductors. The electrode test setup was designed with a special skin dummy which allows investigation of not only the electrical properties of textile electrodes but also the contact behavior between electrode and skin. Using both test setups, eight textile electrodes and five textile conductors were analyzed and compared.

  10. Accuracy of standard craniometric measurements using multiple data formats.

    Science.gov (United States)

    Richard, Adam H; Parks, Connie L; Monson, Keith L

    2014-09-01

    With continuing advancements in biomedical imaging technologies, anthropologists are increasingly making use of data derived from indirect measurement and analysis of skeletal material. To that end, the purpose of this study was to test the reliability of 26 standard craniometric measurements routinely utilized in forensic casework across several different imaging technologies. Measurements from five crania of known individuals were collected in duplicate by two anthropologists via computed tomography (CT) scans and three-dimensional (3D) laser scans of the known skulls. The laser scans were also used to create prototype models of the known skulls. These prototypes were, themselves, laser-scanned, and measurements were also collected from the prototypes and the laser scans of the prototypes. Measurement sets from each technology were then compared with one another using the previously collected osteometric measurements taken on the crania themselves as the ground truth. indicate that, while the majority of measurements showed no significant differences across data formats, a handful were found to be problematic for particular technologies. For instance, measurements taken in a supero-inferior direction (e.g., BBH, OBH) from CT scans were prone to greater deviation from direct measurements of the cranium than other technologies, especially for CT scans taken at 5 mm thickness and increment. Also, several measurements defined by Type 1 landmarks, particularly those occurring at complicated or indistinct suture junctures (e.g., ASB, ZMB), were found to have high variance across all technologies while measurements based on Type 3 landmarks proved to be highly reproducible. This is contrary to measurements taken directly on crania, in which measures defined by Type 1 landmarks are typically the most reliable, likely attributable to diminished or totally obscured suture definition in the scan data. If medical imaging data are to be increasingly utilized in

  11. Joe Celko's Data, Measurements and Standards in SQL

    CERN Document Server

    Celko, Joe

    2009-01-01

    Joe Celko has looked deep into the code of SQL programmers and found a consistent and troubling pattern - a frightening lack of consistency between their individual encoding schemes and those of the industries in which they operate. This translates into a series of incompatible databases, each one an island unto itself that is unable to share information with others in an age of internationalization and business interdependence. Such incompatibility severely hinders information flow and the quality of company data. Data, Measurements and Standards in SQL reveals the shift these programmers nee

  12. Platelet function, anthropometric and metabolic variables in Nigerian ...

    African Journals Online (AJOL)

    Platelet function, anthropometric and metabolic variables in Nigerian Type 2 Diabetic patients. ... (BSA) were assessed as indices of anthropometry, fasting blood sugar (FBS), plasma cholesterol and triglycerides (TAG) were determined using standard method and platelet aggregation test was done on the whole blood.

  13. Relationship Among Body Image, Anthropometric Parameters and Mental Health in Physical Education Students.

    Science.gov (United States)

    Legey, Sandro; Lamego, Murilo Khede; Lattari, Eduardo; Campos, Carlos; Paes, Flávia; Sancassiani, Federica; Mura, Gioia; Carta, Mauro Giovanni; Rocha, Nuno Barbosa F; Nardi, Antônio Egídio; José de Oliveira, Aldair; Neto, Geraldo Maranhão; Murillo-Rodriguez, Eric; Arias-Carrión, Oscar; Budde, Henning; Machado, Sergio

    2016-01-01

    The prevalence of body image dissatisfaction (BID) is currently high. Given that psychological well-being is associated with the body measurements imposed by esthetic standards, BID is an important risk factor for mental disorders. Identify the prevalence of BID, and compare anthropometric and mental health parameters between individuals satisfied and dissatisfied with their body image. A total of 140 university students completed the silhouette scale to screen for BID. Anthropometric measures, body mass index (BMI), waist circumference (WC) and body fat percentage (BFP) were used. To investigate mental health, The State-Trait Anxiety Inventories (STAI-S and STAI-T), Profile of Mood States (POMS) scale and Quality of Life (QOL-36) questionnaire were used to investigate mental health. The Student's t-test was applied to compare anthropometric and mental health parameters. 67.1% of university students exhibited BID. There was a significant difference (p = 0.041) in BF and WC (p = 0.048) between dissatisfied and satisfied individuals. With respect to mood states, significant differences were observed for anger (p = 0.014), depression (p = 0.011), hostility (p = 0.006), fatigue (p = 0.013), mental confusion (p = 0.021) and total mood disturbance (TMD) (p = 0.001). The mental aspect of QOL was significantly higher (p = 0.001) in satisfied university students compared to their dissatisfied counterparts. BID was high and it seems to be influenced by anthropometric measures related to the amount and distribution of body fat. This dissatisfaction may have a negative effect on the quality of life and mood state of young adults.

  14. — study of the use of two standard- and non-standard-measuring devices

    Directory of Open Access Journals (Sweden)

    Paweł Ostapkowicz

    2014-03-01

    Full Text Available This paper deals with leak detection in liquid transmission pipelines. Diagnostic method based on negative pressure wave detection is taken into account here. The paper focuses on variant of this method, related to the use of only two measurement points (devices, placed at the inlet and outlet of the pipeline. Standard transducers for measurement of pressure signals and non-standard elaborated technique for measurement of new diagnostic signals were used. New diagnostic signals, conventionally named the signals of weak interactions, result from the work of special devices (correctors joined to the pipeline. In order to compare both hardware solutions key performance attributes for the analyzed leak detection method were determined. The bases of such assessment were experimental tests. They were conducted with the use of a physical model of a pipeline. The pipeline was 380 meters long, 34 mm in internal diameter and made of polyethylene (PEHD pipes. The medium pumped through the pipeline was water. Carrying out such research, diagnostic procedures elaborated by the author were used and tested.[b]Keywords[/b]: technical diagnostics, pipelines, leak detection

  15. Relating Standardized Visual Perception Measures to Simulator Visual System Performance

    Science.gov (United States)

    Kaiser, Mary K.; Sweet, Barbara T.

    2013-01-01

    Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).

  16. Modeling the wet bulb globe temperature using standard meteorological measurements.

    Science.gov (United States)

    Liljegren, James C; Carhart, Richard A; Lawday, Philip; Tschopp, Stephen; Sharp, Robert

    2008-10-01

    The U.S. Army has a need for continuous, accurate estimates of the wet bulb globe temperature to protect soldiers and civilian workers from heat-related injuries, including those involved in the storage and destruction of aging chemical munitions at depots across the United States. At these depots, workers must don protective clothing that increases their risk of heat-related injury. Because of the difficulty in making continuous, accurate measurements of wet bulb globe temperature outdoors, the authors have developed a model of the wet bulb globe temperature that relies only on standard meteorological data available at each storage depot for input. The model is composed of separate submodels of the natural wet bulb and globe temperatures that are based on fundamental principles of heat and mass transfer, has no site-dependent parameters, and achieves an accuracy of better than 1 degree C based on comparisons with wet bulb globe temperature measurements at all depots.

  17. Cryogenic flow rate measurement with a laser Doppler velocimetry standard

    Science.gov (United States)

    Maury, R.; Strzelecki, A.; Auclercq, C.; Lehot, Y.; Loubat, S.; Chevalier, J.; Ben Rayana, F.

    2018-03-01

    A very promising alternative to the state-of-the-art static volume measurements for liquefied natural gas (LNG) custody transfer processes is the dynamic principle of flow metering. As the Designated Institute (DI) of the LNE (‘Laboratoire National de métrologie et d’Essais’, being the French National Metrology Institute) for high-pressure gas flow metering, Cesame-Exadebit is involved in various research and development programs. Within the framework of the first (2010-2013) and second (2014-2017) EURAMET Joint Research Project (JRP), named ‘Metrological support for LNG custody transfer and transport fuel applications’, Cesame-Exadebit explored a novel cryogenic flow metering technology using laser Doppler velocimetry (LDV) as an alternative to ultrasonic and Coriolis flow metering. Cesame-Exadebit is trying to develop this technique as a primary standard for cryogenic flow meters. Currently, cryogenic flow meters are calibrated at ambient temperatures with water. Results are then extrapolated to be in the Reynolds number range of real applications. The LDV standard offers a unique capability to perform online calibration of cryogenic flow meters in real conditions (temperature, pressure, piping and real flow disturbances). The primary reference has been tested on an industrial process in a LNG terminal during truck refuelling. The reference can calibrate Coriolis flow meters being used daily with all the real environmental constraints, and its utilisation is transparent for LNG terminal operators. The standard is traceable to Standard International units and the combined extended uncertainties have been determined and estimated to be lower than 0.6% (an ongoing improvement to reducing the correlation function uncertainty, which has a major impact in the uncertainty estimation).

  18. Developing a community-based flood resilience measurement standard

    Science.gov (United States)

    Keating, Adriana; Szoenyi, Michael; Chaplowe, Scott; McQuistan, Colin; Campbell, Karen

    2015-04-01

    Given the increased attention to resilience-strengthening in international humanitarian and development work, there has been concurrent interest in its measurement and the overall accountability of "resilience strengthening" initiatives. The literature is reaching beyond the polemic of defining resilience to its measurement. Similarly, donors are increasingly expecting organizations to go beyond claiming resilience programing to measuring and showing it. However, key questions must be asked, in particular "Resilience of whom and to what?". There is no one-size-fits-all solution. The approach to measuring resilience is dependent on the audience and the purpose of the measurement exercise. Deriving a resilience measurement system needs to be based on the question it seeks to answer and needs to be specific. This session highlights key lessons from the Zurich Flood Resilience Alliance approach to develop a flood resilience measurement standard to measure and assess the impact of community based flood resilience interventions, and to inform decision-making to enhance the effectiveness of these interventions. We draw on experience in methodology development to-date, together with lessons from application in two case study sites in Latin America. Attention will be given to the use of a consistent measurement methodology for community resilience to floods over time and place; challenges to measuring a complex and dynamic phenomenon such as community resilience; methodological implications of measuring community resilience versus impact on and contribution to this goal; and using measurement and tools such as cost-benefit analysis to prioritize and inform strategic decision making for resilience interventions. The measurement tool follows the five categories of the Sustainable Livelihoods Framework and the 4Rs of complex adaptive systems - robustness, rapidity, redundancy and resourcefulness -5C-4R. A recent white paper by the Zurich Flood Resilience Alliance traces the

  19. [Measurement of CO diffusion capacity (II): Standardization and quality criteria].

    Science.gov (United States)

    Salcedo Posadas, A; Villa Asensi, J R; de Mir Messa, I; Sardón Prado, O; Larramona, H

    2015-08-01

    The diffusion capacity is the technique that measures the ability of the respiratory system for gas exchange, thus allowing a diagnosis of the malfunction of the alveolar-capillary unit. The most important parameter to assess is the CO diffusion capacity (DLCO). New methods are currently being used to measure the diffusion using nitric oxide (NO). There are other methods for measuring diffusion, although in this article the single breath technique is mainly referred to, as it is the most widely used and best standardized. Its complexity, its reference equations, differences in equipment, inter-patient variability and conditions in which the DLCO is performed, lead to a wide inter-laboratory variability, although its standardization makes this a more reliable and reproductive method. The practical aspects of the technique are analyzed, by specifying the recommendations to carry out a suitable procedure, the calibration routine, calculations and adjustments. Clinical applications are also discussed. An increase in the transfer of CO occurs in diseases in which there is an increased volume of blood in the pulmonary capillaries, such as in the polycythemia and pulmonary hemorrhage. There is a decrease in DLCO in patients with alveolar volume reduction or diffusion defects, either by altered alveolar-capillary membrane (interstitial diseases) or decreased volume of blood in the pulmonary capillaries (pulmonary embolism or primary pulmonary hypertension). Other causes of decreased or increased DLCO are also highlighted. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  20. Validation of Some Anthropometric Equations for Estimating Body ...

    African Journals Online (AJOL)

    Participants weight was measured under water using Hydrostatic weighing equipment. Skinfold was measured at chest, mid axilla, triceps, sub scapular, abdomen, supra iliac, mid thigh, and biceps. Body density (BD) was calculated using underwater weight and anthropometric equations from Behnke and Wilmore, Durning ...

  1. Dietary Acculturation and Predictors of Anthropometric Indicators Among Filipino Americans

    Directory of Open Access Journals (Sweden)

    Reimund C. Serafica

    2013-07-01

    Full Text Available The aim of this study was to explore the relationship of the demographic variables, level of acculturation, dietary consumption of fat, sugar, fruits and vegetables and dietary acculturation to the anthropometric measurement of Filipino Americans (FAs in the United States. The study sample consisted of 128 FAs (N = 128 residing in the southeastern part of the United States. Participants completed the demographics, the Block’s Short Food Frequency Questionnaire (SFFQ, a Short Acculturation Scale for Filipino Americans (ASASFA, and the Dietary Acculturation Questionnaire for Filipino Americans (DAQFA. Anthropometric measurements (waist circumference, hip circumference, weight, and height were also taken. Descriptive statistics analyses and partial least squares (PLS were used to explore the predictive relationships among the variables constructed. The most important positive predictors of the anthropometric indicators were the Western Scale (path coefficient = .503, p < .05 and the intake of fats and sugars (path coefficient = .282, p < .05.

  2. Different methods for assessment of nutritional status in newborn infants based on physical and anthropometric indexes: a short review article

    Directory of Open Access Journals (Sweden)

    Ali Asghar Rashidi

    2017-01-01

    Full Text Available Several complications during childhood is associated with nutritional status of infants at birth. Therefore, nutritional status of newborns must be evaluated properly after birth. Assessment of the nutritional status of neonates based on anthropometric and physical indices is simple and inexpensive without the need for advanced medical equipment. However, no previous studies have focused on the assessment methods of the nutritional status of infants via anthropometric and physical indices. This study aimed to review some of the key methods used to determine the nutritional status of neonates using anthropometric and physical indices. To date, most studies have focused on the diagnosis of fetal malnutrition (FM and growth monitoring. In order to diagnose FM, researchers have used growth charts and Ponderal index (PI based on anthropometric indices, as well as Clinical Assessment of Nutritional (CAN Score based on physical features. Moreover, in order to assess the growth status of infants, growth charts were used. According to the findings of this study, standard intrauterine growth curves and the PI are common measurement tools in the diagnosis of FM. Furthermore, CAN score is widely used in the evaluation of the nutritional status of neonates. Given the differences in the physical features of term and preterm infants, this index should be adjusted for preterm neonates. Longitudinal growth charts are one of the most prominent methods used for monitoring of the growth patterns of infants.

  3. Eye-rima oris distance and its relation to the vertical dimension of occlusion measured by two methods: Anthropometric study in a sample of Yemeni dental students.

    Science.gov (United States)

    Alhajj, Mohammed Nasser; Khalifa, Nadia; Amran, Abdullah

    2016-01-01

    This study was conducted to evaluate the relationship between the distance measured from the distal outer of the eye to the parting line of the lips and the occlusal vertical dimension (OVD) measured by two methods. One hundred and fourteen dental students (76 males and 38 females) were recruited for this study with mean age (22.34 ± 1.83) years. The distance from distal canthus of the eye to rima oris (eye-RO) was compared with two different measurements of the OVD (nasal [N] to gnathion [Gn], and subnasal [Sn] to menton [Me]). All distances were measured using modified digital caliper. Pearson correlation coefficient test for correlations and paired samples t-test for differences were used with a significant level of (P < 0.05). There was a positive significant correlation between the eye-RO distance and the two measurements of the OVD. However, this correlation was stronger between eye-RO and the distance from the tip of the nose to the tip of the chin than that between eye-RO and the distance from the septum of the nose to the under of the chin (r = 0.313 with P = 0.0007, r = 0.296 with P = 0.0014), respectively. The distance from the outer canthus of the eye to the parting of the lips seems to be a reliable method in predicting the OVD and should relate to the distance from the tip of the nose to the tip of the chin.

  4. Sexual Dimorphism and Estimation of Height from Body Length Anthropometric Parameters among the Hausa Ethnic Group of Nigeria

    Directory of Open Access Journals (Sweden)

    Jaafar Aliyu

    2018-01-01

    Full Text Available The study was carried out to investigate the sexual dimorphism in length and other anthropometric parameters. To also generate formulae for height estimation using anthropometric measurements of some length parameters among Hausa ethnic group of Kaduna State, Nigeria. A cross sectional study was conducted and a total of 500 subjects participated in this study which was mainly secondary school students between the age ranges of 16-27 years, anthropometric measurements were obtained using standard protocols. It was observed that there was significant sexual dimorphism in all the parameters except for body mass index. In all the parameters males tend to have significantly (P < 0.05 higher mean values except biaxillary distances. Height showed positive and strongest correlations with demispan length, followed by knee height, thigh length, sitting height, hand length, foot length, humeral length, forearm length and weight respectively. There were weak and positive correlations between height and neck length as well as biaxillary length. The demi span length showed the strongest correlation coefficient and low standard error of estimate indicating the strong estimation ability than other parameters. The combination of two parameters tends to give better estimations and low standard error of estimates, so also combining the three parameters gives better estimations with a lower standard error of estimates. The better correlation coefficient was also observed with the double and triple parameters respectively. Male Hausa tend to have larger body proportion compared to female. Height showed positive and strongest correlations with demispan length. Body length anthropometric proved to be useful in estimation of stature among Hausa ethnic group of Kaduna state Nigeria.

  5. Three-dimensional hindfoot alignment measurements based on biplanar radiographs: comparison with standard radiographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sutter, Reto; Pfirrmann, Christian W.A.; Buck, Florian M. [University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Espinosa, Norman [University Hospital Balgrist, Department of Orthopedic Surgery, Zurich (Switzerland); University of Zurich, Zurich (Switzerland)

    2013-04-15

    To establish a hindfoot alignment measurement technique based on low-dose biplanar radiographs and compare with hindfoot alignment measurements on long axial view radiographs, which is the current reference standard. Long axial view radiographs and low-dose biplanar radiographs of a phantom consisting of a human foot skeleton embedded in acrylic glass (phantom A) and a plastic model of a human foot in three different hindfoot positions (phantoms B1-B3) were imaged in different foot positions (20 internal to 20 external rotation). Two independent readers measured hindfoot alignment on long axial view radiographs and performed 3D hindfoot alignment measurements based on biplanar radiographs on two different occasions. Time for three-dimensional (3D) measurements was determined. Intraclass correlation coefficients (ICC) were calculated. Hindfoot alignment measurements on long axial view radiographs were characterized by a large positional variation, with a range of 14 /13 valgus to 22 /27 varus (reader 1/2 for phantom A), whereas the range of 3D hindfoot alignment measurements was 7.3 /6.0 to 9.0 /10.5 varus (reader 1/2 for phantom A), with a mean and standard deviation of 8.1 {+-} 0.6/8.7 {+-} 1.4 respectively. Interobserver agreement was high (ICC = 0.926 for phantom A, and ICC = 0.886 for phantoms B1-B3), and agreement between different readouts was high (ICC = 0.895-0.995 for reader 1, and ICC = 0.987-0.994 for reader 2) for 3D measurements. Mean duration of 3D measurements was 84 {+-} 15/113 {+-} 15 s for reader 1/2. Three-dimensional hindfoot alignment measurements based on biplanar radiographs were independent of foot positioning during image acquisition and reader independent. In this phantom study, the 3D measurements were substantially more precise than the standard radiographic measurements. (orig.)

  6. Unique Patterns of Body Composition and Anthropometric Measurements During Maturation in Neonatal Intensive Care Unit Neonates: Opportunities for Modifying Nutritional Therapy and Influencing Clinical Outcomes.

    Science.gov (United States)

    Algotar, Anushree; Shaikhkhalil, Ala K; Siler-Wurst, Kim; Sitaram, Swetha; Gulati, Ish; Jadcherla, Sudarshan R

    2018-01-01

    Body composition is an important predictor of long-term outcomes in neonates and may be altered by several factors. Innovative methods like air displacement plethysmography (ADP) can safely and reliably measure body composition, potentially assisting in individualization of nutrition therapy. 1) To characterize patterns of body composition change in convalescing neonates in the neonatal intensive care unit (NICU) and examine factors leading to variation. 2) To evaluate if the time interval between 2 measurements via ADP can detect significant changes. NICU infants underwent anthropometry and body composition measurements by ADP at 37.5±0.7 weeks (Time 1) and 41.0±0.7 weeks (Time 2) postmenstrual age. Nutrition data were recorded. Data were analyzed using paired t-tests and linear regression models, presented as mean±SE, median (IQR), or %. Twenty-two neonates (54% males, 32.2±0.9 weeks gestation) were evaluated with a median interval of 3.6 (2.9-4.0) weeks between studies. Mean weight and % body fat increased significantly. There was no significant difference between mean weight and mean % body fat compared with normal references. Abdominal girth increased and mid-arm circumference decreased (pcomposition can effectively assess nutrition status of fragile NICU infants. Although, an interval of 2.9-4.0 weeks between consecutive measurements detected significant changes in body composition, more frequent measurements are needed to determine nutrition factors responsible for body composition changes. © 2017 American Society for Parenteral and Enteral Nutrition.

  7. Standardized fluoroscopy-based technique to measure intraoperative cup anteversion.

    Science.gov (United States)

    Zingg, Matthieu; Boudabbous, Sana; Hannouche, Didier; Montet, Xavier; Boettner, Friedrich

    2017-10-01

    Direct anterior approach (DAA) with the patient lying supine has facilitated the use of intraoperative fluoroscopy and allows for standardized positioning of the patient. The current study presents a new technique to measure acetabular component anteversion using intraoperative fluoroscopy. The current paper describes a mathematical formula to calculate true acetabular component anteversion based on the acetabular component abduction angle and the c-arm tilt angle (CaT). The CaT is determined by tilting the c-arm until an external pelvic oblique radiograph with the equatorial plane of the acetabular component perpendicular to the fluoroscopy receptor is obtained. CaT is determined by direct reading on the C-arm device. The technique was validated using a radiopaque synbone model comparing the described technique to computed tomography anteversion measurement. The experiment was repeated 25 times. The difference in anteversion between the two measuring techniques was on average 0.2° (range -3.0-3.1). The linear regression coefficients evaluating the agreement between the experimental and control methods were 0.99 (95%CI 0.88-1.10, p < 0.001) and 0.33 (95%CI -1.53-2.20, p = 0.713) for the slope and intercept, respectively. The current study confirms that the described three-step c-arm acetabular cup measuring technique can reproducibly and reliably assess acetabular component anteversion in the supine position, as compared to CT-imaging. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2307-2312, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  8. Multicenter Evaluation of Cystatin C Measurement after Assay Standardization.

    Science.gov (United States)

    Bargnoux, Anne-Sophie; Piéroni, Laurence; Cristol, Jean-Paul; Kuster, Nils; Delanaye, Pierre; Carlier, Marie-Christine; Fellahi, Soraya; Boutten, Anne; Lombard, Christine; González-Antuña, Ana; Delatour, Vincent; Cavalier, Etienne

    2017-04-01

    Since 2010, a certified reference material ERM-DA471/IFCC has been available for cystatin C (CysC). This study aimed to assess the sources of uncertainty in results for clinical samples measured using standardized assays. This evaluation was performed in 2015 and involved 7 clinical laboratories located in France and Belgium. CysC was measured in a panel of 4 serum pools using 8 automated assays and a candidate isotope dilution mass spectrometry reference measurement procedure. Sources of uncertainty (imprecision and bias) were evaluated to calculate the relative expanded combined uncertainty for each CysC assay. Uncertainty was judged against the performance specifications derived from the biological variation model. Only Siemens reagents on the Siemens systems and, to a lesser extent, DiaSys reagents on the Cobas system, provided results that met the minimum performance criterion calculated according to the intraindividual and interindividual biological variations. Although the imprecision was acceptable for almost all assays, an increase in the bias with concentration was observed for Gentian reagents, and unacceptably high biases were observed for Abbott and Roche reagents on their own systems. This comprehensive picture of the market situation since the release of ERM-DA471/IFCC shows that bias remains the major component of the combined uncertainty because of possible problems associated with the implementation of traceability. Although some manufacturers have clearly improved their calibration protocols relative to ERM-DA471, most of them failed to meet the criteria for acceptable CysC measurements. © 2016 American Association for Clinical Chemistry.

  9. Malnutrition among HIV- infected Children by Anthropometric Measures in Poor Outreach Area of a Developing Country and its Relationship with CD4 Counts

    Directory of Open Access Journals (Sweden)

    Ritu Rakholia

    2016-04-01

    Conclusion: Malnutrition is rampant in children with HIV/AIDS in hilly poor Outreach areas of India. Chronic malnutrition or stunting was the most common abnormality seen in three fourth of all the children. Hence sensitizing health care workers for timely recognition and prompt remedial measures (ART, nutritional interventions are need of the hour to reduce mortality and prevent growth failure. It also provides baseline data of efficacy of single dose nevirapine to compare efficacy of newer regimes in prevention of PPTCT.

  10. Humidity correction in the standard measurement of exposure

    International Nuclear Information System (INIS)

    Ibaraki, Yasuyuki; Katoh, Akira

    1980-01-01

    This paper deals with the humidity correction to be made in the standard measurement of the exposure to the measured ionization current in the humid air for the purpose of excluding the influence of the water vapour that is not included in the definition of the exposure. First, formulae giving the humidity correction factors for a parallel plate free air chamber and a cavity chamber have been derived respectively in the case where the contributions of air and water vapour to the ionization are independent. Next, in the case where the contributions are not independent, i.e., the Jesse effect is taken into account, a formula to obtain the W-value for humid air has been derived on the basis of the Niatel's experimental result. Using this formula, formulae to obtain the humidity correction factors for the free air chamber and the cavity chamber are derived. The humidity calculated by the latter formulae show good agreements with the results by Niatel and Guiho, respectively. (author)

  11. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  12. Estudo antropométrico do crânio de recém-nascidos normais em Sergipe Anthropometric cranial measurements of normal newborn in Sergipe - Northeast of Brazil

    Directory of Open Access Journals (Sweden)

    Hélio A. Oliveira

    2007-09-01

    Full Text Available O estudo antropométrico do crânio é fundamental para a avaliação do recém-nascido. As medidas antropométricas usadas na atualidade são baseadas em resultados obtidos há mais de cinco décadas, os quais não são capazes de determinar um padrão nacional em decorrência de possíveis influências de algumas etnias. Realizamos estudo descritivo analítico em uma Maternidade em Aracaju-SE, com medidas de perímetro cefálico, distancia biauricular e anteroposterior, índice cefálico e medida da fontanela; foram examinadas 450 recém-nascidos com idade gestacional entre 37 e 42 semanas; 49,3% era do gênero masculino e 50,6% do feminino. O perímetro cefálico variou entre 30,0 cm e 39,8 cm com média de 34,14±2,48 com P50 34 cm. O índice cefálico variou entre 0,69 e 1,13 com média de 0,98±0,06 com P50 1. Foi feito uma comparação entre os estudos estrangeiros e brasileiros; o recém-nascido sergipano aproxima-se mais dos resultados obtidos nos estudos da região sudeste do que dos resultados da região nordeste, geograficamente semelhante. A possibilidade de influencias étnicas foi levantada, como também a necessidade de realizar um estudo multicêntrico para criar um perfil antropométrico do recém-nascido brasileiro.The anthropometric mesureaments of the skull is essential for the evaluation of the newborn. The anthropometrics measureaments utilized at the present time are based in the results obtained for more than five decades, which are not able to determine a national pattern mostly likely due to some ethnic influences. We carried out an analytical descriptive study in a maternity hospital in Aracaju-Sergipe, Northeast of Brazil. Measurements of cephalic perimeter, biauricular and anteroposterior distances, cephalic index and fontanels were obtained from 450 newborns with gestacional age from 37 and 42 weeks; 49.3% were male and 50.6% female. The cephalic perimeter ranged from 30.0 cm to 39.8 cm with mean value of 34.14±2

  13. Utilização de medidas antropométricas para a avaliação do acúmulo de gordura visceral The use of anthropometric measures to assess visceral fat accumulation

    Directory of Open Access Journals (Sweden)

    Ana Carolina Junqueira Vasques

    2010-02-01

    accurate and precise measurement of visceral fat. However, both are costly and inapplicable in routine clinical practice and epidemiological studies. Anthropometric parameters are an option for visceral fat assessment in these situations, since they are innocuous, easy to use and inexpensive. In this context, this work aimed to critically analyze studies that assessed anthropometric parameters as indicators of visceral fat. A bibliographic review of domestic and international articles found in the databases Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Scientific Electronic Library Online, Science Direct and Pubmed, published from 1947 to 2007 was done. Emphasis was given to anthropometric parameters, such as body mass index, waist circumference, waist-to-hip ratio and sagittal abdominal diameter.

  14. A Network for Standardized Ocean Color Validation Measurements

    Science.gov (United States)

    Zibordi, Giuseppe; Holben, Brent; Hooker, Stanford; Melin, Frederic; Berthon, Jean-Francois; Slutsker, Ilya; Giles, David; Vandemark, Doug; Feng, Hui; Rutledge, Ken; hide

    2006-01-01

    The Aerosol Robotic Network (AERONET) was developed to support atmospheric studies at various scales with measurements from worldwide distributed autonomous sunphotometers [Holben et al. 1998]. AERONET has now extended its support to marine applications through the additional capability of measuring the radiance emerging from the sea with modified sun-photometers installed on offshore platforms like lighthouses, navigation aids, oceanographic and oil towers. The functionality of this added network component called AERONET - Ocean Color (AERONET-OC), has been verified at different sites and deployment structures over a four year testing phase. Continuous or occasional deployment platforms (see Fig. 1) included: the Acqua Alta Oceanographic Tower (AAOT) of the Italian National Research Council in the northern Adriatic Sea since spring 2002; the Martha s Vineyard Coastal Observatory (MVCO) tower of the Woods Hole Oceanographic Institution in the Atlantic off the Massachusetts coast for different periods since spring 2004; the TOTAL Abu-Al-Bukhoosh oil Platform (AABP, shown through an artistic rendition in Fig. 1) in the Persian (Arabian) Gulf in fall 2004; the Gustaf Dal n Lighthouse Tower (GDLT) of the Swedish Maritime Administration in the Baltic Sea in summer 2005; and the platform at the Clouds and the Earth's Radiant Energy System (CERES) Ocean Validation Experiment (COVE) site located in the Atlantic Ocean off the Virginia coast since fall 2005. Data collected during the network testing phase, confirm the capability of AERONET-OC to support the validation of marine optical remote sensing products through standardized measurements of normalized water-leaving radiance, LWN, and aerosol optical thickness, a, at multiple coastal sites.

  15. Anthropometric profile of Hong Kong children and adolescents: the Wellness Population of Youth Study.

    Science.gov (United States)

    Lee, Regina L T; Lee, Paul H; Sze, Daniel M Y; Chien, Wai Tong

    2017-04-01

    Childhood obesity has been a public health concern increasingly. We investigated the age- and sex-specific body mass index (BMI), blood pressure level, and other obesity measures in Hong Kong children and adolescents. We used the data from Wellness Population of Youth Study, a health examination for anthropometric measurements among children and adolescents (aged 9-15 years) in Hong Kong, conducted in Oct 2012-Jun 2013 (n = 4410). Anthropometric measures including weight, height, pulse, systolic and diastolic blood pressures, triceps and scapula skinfold thickness, and waist circumference were measured following universal standard protocol. Overweight and obesity were classified using the 2000 International Obesity Task Force, 2007 World Health Organization, and 2000 Centers of Disease Control and Prevention age- and sex-specific growth charts. Hypertension was categorized using Centers of Disease Control and Prevention and Chinese standards. The prevalence of obesity, overweight, and hypertension of Hong Kong adolescents according to the above definitions were 5.4%-15.1%, 20.8%-25.9%, and 12.0%-13.8%, respectively. Boys had higher systolic blood pressure, waist, BMI, and waist-to-height ratio (all P Hong Kong children and adolescents were more severe. Copyright © 2017 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  16. Measuring and diagnosing unilateral neglect: a standardized statistical procedure.

    Science.gov (United States)

    Toraldo, Alessio; Romaniello, Cristian; Sommaruga, Paolo

    Unilateral neglect is usually investigated by adminstering stimuli (targets) in different positions, with targets being responded to by the patient (Hit) or omitted. In spite of this homogeneity of data type, neglect indices and diagnostic criteria vary considerably, causing inconsistencies in both clinical and experimental settings. We aimed at deriving a standard analysis which would apply to all tasks sharing this data form. A-priori theoretical reasoning demonstrated that the mean position of Hits in space (MPH) is an optimal index for correctly diagnosing and quantifying neglect. Crucially MPH eliminates the confounding effects of deficits that are different from neglect (non-lateral) but which decrease Hit rate. We ran a Monte Carlo study to assess MPH's (so far overlooked) statistical behavior as a function of numbers of targets and Hits. While average MPH was indeed insensitive to non-lateral deficits, MPH's variance (like that of all other neglect indices) increased dramatically with increasing non-lateral deficits. This instability would lead to alarmingly high false-positive rates (FPRs) when applying a classical diagnostic procedure that compares one patient with a control sample. We solved the problem by developing an equation that takes into account MPH instability and provides correct cut-offs and close-to-nominal FPRs, even without control subjects. We developed a computerized program which, given the raw data, yields the MPH, a z-score and a p-value. We provided a standard method that allows clinical and experimental neuropsychologists to diagnose and measure neglect in a consistent way across the vast majority of tasks.

  17. Breast composition measurements using retrospective standard mammogram form (SMF)

    International Nuclear Information System (INIS)

    Highnam, R; Pan, X; Warren, R; Jeffreys, M; Smith, G Davey; Brady, M

    2006-01-01

    The standard mammogram form (SMF) representation of an x-ray mammogram is a standardized, quantitative representation of the breast from which the volume of non-fat tissue and breast density can be easily estimated, both of which are of significant interest in determining breast cancer risk. Previous theoretical analysis of SMF had suggested that a complete and substantial set of calibration data (such as mAs and kVp) would be needed to generate realistic breast composition measures and yet there are many interesting trials that have retrospectively collected images with no calibration data. The main contribution of this paper is to revisit our previous theoretical analysis of SMF with respect to errors in the calibration data and to show how and why that theoretical analysis did not match the results from the practical implementations of SMF. In particular, we show how by estimating breast thickness for every image we are, effectively, compensating for any errors in the calibration data. To illustrate our findings, the current implementation of SMF (version 2.2β) was run over 4028 digitized film-screen mammograms taken from six sites over the years 1988-2002 with and without using the known calibration data. Results show that the SMF implementation running without any calibration data at all generates results which display a strong relationship with when running with a complete set of calibration data, and, most importantly, to an expert's visual assessment of breast composition using established techniques. SMF shows considerable promise in being of major use in large epidemiological studies related to breast cancer which require the automated analysis of large numbers of films from many years previously where little or no calibration data is available

  18. Anthropometrics, Physical Performance, and Injury Characteristics of Youth American Football.

    Science.gov (United States)

    Caswell, Shane V; Ausborn, Ashley; Diao, Guoqing; Johnson, David C; Johnson, Timothy S; Atkins, Rickie; Ambegaonkar, Jatin P; Cortes, Nelson

    2016-08-01

    Prior research has described the anthropometric and physical performance characteristics of professional, collegiate, and high school American football players. Yet, little research has described these factors in American youth football and their potential relationship with injury. To characterize anthropometric and physical performance measures, describe the epidemiology of injury, and examine the association of physical performance measures with injury among children participating within age-based divisions of a large metropolitan American youth football league. Case-control study; Level of evidence, 3. Demographic, anthropometric, and physical performance characteristics and injuries of 819 male children were collected over a 2-year period (2011-2012). Injury data were collected by the league athletic trainer (AT) and coaches. Descriptive analysis of demographic, anthropometric, and physical performance measures (40-yard sprint, pro-agility, push-ups, and vertical jump) were conducted. Incidence rates were computed for all reported injuries; rates were calculated as the number of injuries per 1000 athlete-exposures (AEs). Multinomial logistic regression was used to identify whether the categories of no injury, no-time-loss (NTL) injury, and time-loss (TL) injury were associated with physical performance measures. Of the 819 original participants, 760 (92.8%) completed preseason anthropometric measures (mean ± SD: age, 11.8 ± 1.2 years; height, 157.4 ± 10.7 cm; weight, 48.7 ± 13.3 kg; experience, 2.0 ± 1.8 years); 640 (78.1%) players completed physical performance measures. The mean (±SD) 40-yard sprint and pro-agility measures of the players were 6.5 ± 0.6 and 5.7 ± 0.5 seconds, respectively; the number of push-ups and maximal vertical jump height were 16.5 ± 9.3 repetitions and 42.3 ± 8.4 cm, respectively. Players assigned to different teams within age divisions demonstrated no differences in anthropometric measures; 40-yard dash and pro-agility times

  19. The value of anthropometric indices for identifying women with features of metabolic syndrome

    Science.gov (United States)

    BMI is a widely used anthropometric measure for identifying CVD and metabolic syndrome (MetS) risk. Two new anthropometric indices are A Body Shape Index (ABSI) and Body Roundness Index (BRI) that may provide better correlations to features of MetS. Methods: Subject data were obtained from 91 over...

  20. Anthropometric, physical and motor fitness profiles of 10 to 15-year ...

    African Journals Online (AJOL)

    Anthropometric, physical and motor fitness profiles of 10 to 15-year old girls in the north west province of South Africa: implications for sport talent ... African Journal for Physical Activity and Health Sciences ... The tests consisted of four anthropometrical measurements, six physical fitness tests and five motor fitness tests.

  1. Adipokine serum concentrations, anthropometric measurements and socio-economic status in two ethnic groups with different prevalence levels for cardiovascular diseases and type 2 diabetes.

    Science.gov (United States)

    Waisberg, R; Paiker, J E; Crowther, N J

    2011-08-01

    Obesity is more common in African than Asian-Indian populations and yet type 2 diabetes and cardiovascular diseases are more common in the latter populations. The main purpose of the current study was therefore to determine whether ethnic differences in body fat distribution, adipokine levels, and socio-economic status may explain population differences in the prevalence of these metabolic disorders. Leptin, IL-6, CRP, visceral fat, education level, and socio-economic status were measured in 50 African and the same number of Indian women residing in Johannesburg, South Africa. Serum leptin levels were significantly higher in Indian than African subjects (41.3±2.0 and 34.2±2.9 ng/ml, respectively; pAfrican group, (5.22±0.86 vs. 2.54±0.52 pg/ml; peconomic status (pAfrican subjects, however, adjusting for these variables in ANCOVA did not attenuate differences in adipokine or visceral fat levels. We hypothesise that one of the reasons for the higher prevalence of obesity in the African than Indian population may be related to lower leptin levels, whilst ethnic differences in the prevalence of metabolic disorders cannot be explained by differences in adipokine levels, but maybe related to higher visceral adiposity in the Indian group. Georg Thieme Verlag KG Stuttgart · NewYork.

  2. ANTHROPOMETRIC AND MOTORIC COMPARISONS BETWEEN THE TWO VOLLEYBALL TEAMS IN PRISHTINA

    Directory of Open Access Journals (Sweden)

    Malsor Gjonbalaj

    2014-06-01

    Full Text Available Introduction: The increase in sports results today not only identifies the quantity (volume and intensity of the work put in, but also the quality (changing the stereotypical notion of effort, eliminating redundant movements, rationalizing the sport in all elements etc. All of these circumstances and factors referred in this paper are stimulated through practical methods for processing positive results and aiming to present a realistic and factual reflection of the current condition, particularly emphasizing the evaluation of several anthropometric and motor characteristics of the players in both volleyball clubs from Prishtina. Methods: These methods are elaborated among arithmetic methods, variance, standard deviation and standard error of the arithmetic mean, the coefficient of variance, the maximum and minimum score test, the score in accordance to the Pearson correlation coefficient-whereas the instruments measured 14 variables such as anthropometric 8, 4 motors and 2 situational. The main purpose to which is addressed in this paper is verifying the situation and the differences between the players in two of the clubs by analyzing the results from the variables I have chosen. Results: The results show that there is a significant differentiation between one volleyball group to the other in terms of motor, anthropometric and situational. This is proven by the results of the data based on the parameters abovementioned. Discussion: Results acquired on in the research, verifies the hypotheses which sets forth previously, it helps to us to understand that the main goal in this research has largely been achieved. Statistical methods that have been processed results may explain the state of anthropometric and motor characteristics. Moreover, with the help of T-test we came to understand the valuable statistical differences between two clubs which have been subject to research. These results are best justified considering the fact that the first

  3. Evaluation of some anthropometric indices for the diagnosis of ...

    African Journals Online (AJOL)

    EB

    Methods: Anthropometric measurements were carried out on cohorts of pregnant women from 4 hospitals in Enugu,. South-eastern Nigeria. Results: There ... referred to as obesity, is a major risk factor for poor pregnancy outcome.1,2 It is most ... symptoms such as stress incontinence and urgency.1,9,11-16 Furthermore, the ...

  4. The introduction of anthropometrics into development and economics

    OpenAIRE

    Komlos, John; Meermann, Lukas

    2007-01-01

    'The authors trace the introduction and use of anthropometric indicators (height, weight, body mass index) into development and labor economics in the late 1970s. These biological markers are used as a proxy measure for health human capital, the degree of poverty or malnutrition, net nutritional status, and productive capacity. The use of these indicators has spread rapidly after the 1980s.' (author's abstract)

  5. Anthropometric characteristics and lower limb power of professional ...

    African Journals Online (AJOL)

    The 35 anthropometric measurements, complemented by a biomechanical evaluation of lower limb power using the counter movement jump (CMJ), were examined. The values of height, length, width and body circumference were significantly higher for female volleyball players than those obtained from the reference group ...

  6. Anthropometric status of Pretoria children of four populations ...

    African Journals Online (AJOL)

    Total percentage increases per 10 years of growth and average triennial percentage increases were calculated for 11 anthropometric variables in males and females aged 6-15 years from four South African populations studied crossseetionally. The. increase of various measurements for each population was discussed and ...

  7. Estimations of isoprenoid emission capacity from enclosure studies: measurements, data processing, quality and standardized measurement protocols

    Science.gov (United States)

    Niinemets, Ü.; Kuhn, U.; Harley, P. C.; Staudt, M.; Arneth, A.; Cescatti, A.; Ciccioli, P.; Copolovici, L.; Geron, C.; Guenther, A.; Kesselmeier, J.; Lerdau, M. T.; Monson, R. K.; Peñuelas, J.

    2011-08-01

    The capacity for volatile isoprenoid production under standardized environmental conditions at a certain time (ES, the emission factor) is a key characteristic in constructing isoprenoid emission inventories. However, there is large variation in published ES estimates for any given species partly driven by dynamic modifications in ES due to acclimation and stress responses. Here we review additional sources of variation in ES estimates that are due to measurement and analytical techniques and calculation and averaging procedures, and demonstrate that estimations of ES critically depend on applied experimental protocols and on data processing and reporting. A great variety of experimental setups has been used in the past, contributing to study-to-study variations in ES estimates. We suggest that past experimental data should be distributed into broad quality classes depending on whether the data can or cannot be considered quantitative based on rigorous experimental standards. Apart from analytical issues, the accuracy of ES values is strongly driven by extrapolation and integration errors introduced during data processing. Additional sources of error, especially in meta-database construction, can further arise from inconsistent use of units and expression bases of ES. We propose a standardized experimental protocol for BVOC estimations and highlight basic meta-information that we strongly recommend to report with any ES measurement. We conclude that standardization of experimental and calculation protocols and critical examination of past reports is essential for development of accurate emission factor databases.

  8. Anthropometric and Cardiovascular Variables of Elite Athletes

    Directory of Open Access Journals (Sweden)

    Kyselovičová Oľga

    2016-11-01

    Full Text Available Synchronized swimming and aerobic gymnastics are competitive sports that have grown in popularity throughout the Slovakia and around the world. Unfortunately, a paucity of research exists either on anthropometric and physiological characteristics or physical benefits of these sports. The present study examined anthropometric and cardiovascular characteristics of control group - CO (n = 10 in comparison to competitive synchronized swimmers - SS (n = 11 and aerobic gymnasts - AG (n = 10 between the ages of 13 and 25 years. The physical measures were assessed per the protocols in the following order: height (BH, weight (BW, body mass index (BMI, and % body fat (% BF. The measurements of maximal oxygen consumption (VO2max and maximum heart rate (HRmax were examined by spiroergometry via COSMED K4b2. All measurements were collected by trained data collection staff. An analysis of variance (Kruskal - Wallis with a Mann-Whitney U test for the significant effect among the three groups showed that aerobic gymnasts were taller than synchronized swimmers and control group (p = .02. Training and conditioning requirements specific for the two athletic groups caused that AG and SS have higher level of VO2max (p = .02 and VO2max.kg-1 (p = .00, and also lower level of the body weight (p= .01, BMI (p = .01 and the % BF (p = .00. These findings confirm that selected parameters are considered the bases for success in elite sports. This information could also help to design specific training and evaluate the adaptation to training stimuli with the aim to maximize sport performance.

  9. Anthropometric profiles of elite Asian female handball players.

    Science.gov (United States)

    Hasan, A A; Reilly, T; Cable, N T; Ramadan, J

    2007-06-01

    Handball has increased in status as a sport since its introduction in 1972 into the Summer Olympic Games. Whereas anthropometric profiles of female athletes have been reported for certain sports, data for elite handball players are limited. The current study was based on anthropometric measurements of 60 female Asian handball players competing in the continental championship, the aim being to identify any differences between countries and between playing positions. The setting was the 12(th) Asian Games in Hiroshima, Japan. Anthropometric data were obtained from 60 players including teams from China, Japan, Kazakhstan and South Korea. Measurements included height, mass, skinfold thicknesses: from these measures percent body fat and muscle mass were estimated. Profiles were compared between 4 nations and 4 positional roles by means of ANOVA. Overall, mean (SD) values were 1.708 (0.068) m, 64.6 (7.7) kg, 20.8% (4.4%), 39.6% (5.2%) for stature, mass, percent body fat and percent muscle mass, respectively. There were small differences between players from different countries but no significant (P>0.05) influence of playing position. Players from Japan were shortest, lightest and lowest in adiposity. The Chinese players were tallest and had the greatest muscle mass. These female international handball players differed in some respects in anthropometric characteristics according to their country of origin. The Asian players were found to be relatively homogeneous across the different positions.

  10. Radio Astronomers Set New Standard for Accurate Cosmic Distance Measurement

    Science.gov (United States)

    1999-06-01

    estimate of the age of the universe. In order to do this, you need an unambiguous, absolute distance to another galaxy. We are pleased that the NSF's VLBA has for the first time determined such a distance, and thus provided the calibration standard astronomers have always sought in their quest for accurate distances beyond the Milky Way," said Morris Aizenman, Executive Officer of the National Science Foundation's (NSF) Division of Astronomical Sciences. "For astronomers, this measurement is the golden meter stick in the glass case," Aizenman added. The international team of astronomers used the VLBA to measure directly the motion of gas orbiting what is generally agreed to be a supermassive black hole at the heart of NGC 4258. The orbiting gas forms a warped disk, nearly two light-years in diameter, surrounding the black hole. The gas in the disk includes water vapor, which, in parts of the disk, acts as a natural amplifier of microwave radio emission. The regions that amplify radio emission are called masers, and work in a manner similar to the way a laser amplifies light emission. Determining the distance to NGC 4258 required measuring motions of extremely small shifts in position of these masers as they rotate around the black hole. This is equivalent to measuring an angle one ten-thousandth the width of a human hair held at arm's length. "The VLBA is the only instrument in the world that could do this," said Moran. "This work is the culmination of a 20-year effort at the Harvard Smithsonian Center for Astrophysics to measure distances to cosmic masers," said Irwin Shapiro, Director of that institution. Collection of the data for the NGC 4258 project was begun in 1994 and was part of Herrnstein's Ph.D dissertation at Harvard University. Previous observations with the VLBA allowed the scientists to measure the speed at which the gas is orbiting the black hole, some 39 million times more massive than the Sun. They did this by observing the amount of change in the

  11. Anthropometric characterisation of elbow angles and lines among Indian children

    Directory of Open Access Journals (Sweden)

    Bhanu Awasthi

    2017-01-01

    Full Text Available Background: For understanding injuries in paediatric elbow and checking the degree of reduction after manipulation, various radiological criteria using anthropometric parameters are used. Since anthropometric parameters of Caucasians are different from European and Mongoloids, their parameters cannot be applied on our population. Hence, there is a need to characterise anthropometric parameters of elbow among children in the Indian population. Materials and Methods: The study population comprised all cases of injury to the elbow joint between 3 and 13 years of age reporting to the Department of Orthopaedics during the study. The X-rays films were preserved, and the angles and lines (as anthropometric parameters were drawn on the radiographs. Results: Mean ± (standard deviation [SD] for Baumann angle in children included in this study was 75° ± 4.70°. Mean ± (SD of Baumann angle in males was 76° ± 4.44° and females was 74° ± 5.37°. Mean ± (SD for lateral capitellohumeral angle in children from 3 to 13 years of age was 49 ± 5.75. Conclusions: As the values of normal side have been found to affect the functional and cosmetic outcome of the affected extremity, slight changes in values of our population in comparison to that of the Western population can significantly affect the outcome.

  12. Biomechanical, anthropometric, and psychological determinants of barbell back squat strength.

    Science.gov (United States)

    Vigotsky, Andrew D; Bryanton, Megan A; Nuckols, Greg; Beardsley, Chris; Contreras, Bret; Evans, Jessica; Schoenfeld, Brad J

    2018-02-27

    Previous investigations of strength have only focused on biomechanical or psychological determinants, while ignoring the potential interplay and relative contributions of these variables. The purpose of this study was to investigate the relative contributions of biomechanical, anthropometric, and psychological variables to the prediction of maximum parallel barbell back squat strength. Twenty-one college-aged participants (male = 14; female = 7; age = 23 ± 3 years) reported to the laboratory for two visits. The first visit consisted of anthropometric, psychometric, and parallel barbell back squat one-repetition maximum (1RM) testing. On the second visit, participants performed isometric dynamometry testing for the knee, hip, and spinal extensors in a sticking point position-specific manner. Multiple linear regression and correlations were used to investigate the combined and individual relationships between biomechanical, anthropometric, and psychological variables and squat 1RM. Multiple regression revealed only one statistically predictive determinant: fat free mass normalized to height (standardized estimate ± SE = 0.6 ± 0.3; t(16) = 2.28; p = 0.037). Correlation coefficients for individual variables and squat 1RM ranged from r = -0.79-0.83, with biomechanical, anthropometric, experiential, and sex predictors showing the strongest relationships, and psychological variables displaying the weakest relationships. These data suggest that back squat strength in a heterogeneous population is multifactorial and more related to physical rather than psychological variables.

  13. Craniofacial proportions and anthropometric measurements among ...

    African Journals Online (AJOL)

    Introduction: Untreated children with growth hormone deficiency (GHD) have typical somatic features, including short stature, acromicria and distinctive craniofacial features including small head circumference. Patients and Methods: By using a cross sectional study design, we investigated the effect of GHD on craniofacial ...

  14. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Treatment of High Blood Pressure (JNC-7),8 with the subjects sitting quietly and the right arm on a table at the level of the heart. An appropriately sized cuff, covering at least two-thirds of the upper arm with the lower border not less than 2.5 cm from the cubital fossa, was applied after restricting clothing had been removed.

  15. Anthropometric data as predictors of Obstructive Sleep Apnea Severity.

    Science.gov (United States)

    Pinto, José Antonio; Godoy, Luciana Ballester de Mello; Marquis, Valéria Wanderley Pinto Brandão; Sonego, Thiago Branco; Leal, Carolina de Farias Aires; Artico, Marina Spadari

    2011-01-01

    The Obstructive Sleep Apnea Syndrome is a chronic disease characterized by episodes upper airway collapse, and has been associated with increased cardiovascular morbidity. To correlate the neck, abdominal and pelvic circumference with the AHI and oxyhemoglobin saturation in OSA patients, and to correlate these values with disease severity. A prospective descriptive study of 82 patients evaluated complaints suggesting OSA, from July 2008 to March 2010. All patients underwent polysomnography, an ENT clinical exam, measures of the BMI, abdominal, pelvic, and cervical circumferences. The mean, standard deviations and Spearman's correlations were analyzed. The mean AHI in men was 39 events/hr; in women it was 21 events/hr in women. The mean neck circumference was 34. 5 cm in women and 41. 3 cm in men, the mean abdominal circumference was 94. 3 cm in women and 101. 5 cm in men, and the pelvic circumference was 105. 7 cm in men and 108. 7 cm in women. The neck circumference correlated more closely to the AHI in men (r = + 0. 389 p = 0. 001). The relationship between the abdominal circumference correlated more with AHI than with the BMI in men (AbC r = + 0. 358 p = 0. 003 BMI r = + 0. 321 p = 0. 009). The neck circumference is the best anthropometric measurement of respiratory disorder severity compared to the AbC or the BMI.

  16. Implementation of a consolidated, standardized database of environmental measurements data

    International Nuclear Information System (INIS)

    James, T.L.

    1996-10-01

    This report discusses the benefits of a consolidated and standardized database; reasons for resistance to the consolidation of data; implementing a consolidated database, including attempts at standardization, deciding what to include in the consolidated database, establishing lists of valid values, and addressing quality assurance/quality control (QA/QC) issues; and the evolution of a consolidated database, which includes developing and training a user community, resolving configuration control issues, incorporating historical data, identifying emerging standards, and developing pointers to other data. OREIS is used to illustrate these topics

  17. Basement Construction of Measurement Standardization for Thermal Property and Basement Preparation of Industrial Technology

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kweon Ho; Song, Kee Chan; Park, Chang Je

    2007-02-15

    There are three main categories in this report : 1)Basement construction of measurement standardization for nuclear material thermal property, 2) Reliability evaluation of measurement instrument, and 3) Standardization and industrial propagation.

  18. Use and interpretation of anthropometric indicators of nutritional status*

    OpenAIRE

    1986-01-01

    Studies carried out during the last decade have led to a better understanding of the value of anthropometric indicators of nutritional status. The present report concentrates on data concerning 0-5-year-old children and examines the indices of weight and height and the biological significance of ”wasting” and ”stunting”. The need for a reference population as well as for a standard or target is recognized and the advantages and disadvantages of local versus international reference populations...

  19. 34 CFR 106.43 - Standards for measuring skill or progress in physical education classes.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Standards for measuring skill or progress in physical... Education Programs or Activities Prohibited § 106.43 Standards for measuring skill or progress in physical education classes. If use of a single standard of measuring skill or progress in physical education classes...

  20. Relationship between anthropometric parameters and the location ...

    African Journals Online (AJOL)

    Background: Childhood growth is characterized by changes in anthropometric parameters. The location of the apex beat may be similarly influenced by growth. Objectives: The objective of this study was to determine any relationship between the location of the apex beat and anthropometric parameters. Subjects and ...

  1. Estimations of isoprenoid emission capacity from enclosure studies: measurements, data processing, quality and standardized measurement protocols

    Directory of Open Access Journals (Sweden)

    Ü. Niinemets

    2011-08-01

    Full Text Available The capacity for volatile isoprenoid production under standardized environmental conditions at a certain time (ES, the emission factor is a key characteristic in constructing isoprenoid emission inventories. However, there is large variation in published ES estimates for any given species partly driven by dynamic modifications in ES due to acclimation and stress responses. Here we review additional sources of variation in ES estimates that are due to measurement and analytical techniques and calculation and averaging procedures, and demonstrate that estimations of ES critically depend on applied experimental protocols and on data processing and reporting. A great variety of experimental setups has been used in the past, contributing to study-to-study variations in ES estimates. We suggest that past experimental data should be distributed into broad quality classes depending on whether the data can or cannot be considered quantitative based on rigorous experimental standards. Apart from analytical issues, the accuracy of ES values is strongly driven by extrapolation and integration errors introduced during data processing. Additional sources of error, especially in meta-database construction, can further arise from inconsistent use of units and expression bases of ES. We propose a standardized experimental protocol for BVOC estimations and highlight basic meta-information that we strongly recommend to report with any ES measurement. We conclude that standardization of experimental and calculation protocols and critical examination of past reports is essential for development of accurate emission factor databases.

  2. Medidas antropométricas como preditoras de fatores de risco cardiovascular na população urbana do Irã Anthropometric measures as predictors of cardiovascular disease risk factors in the urban population of Iran

    Directory of Open Access Journals (Sweden)

    Reza Gharakhanlou

    2012-02-01

    are an important public health problem in society, due to their association with various chronic diseases. OBJECTIVE: The purpose of this study is to determine the prevalence and distribution of overweight and obesity, using different anthropometric measurements and to identify the best anthropometric indicator which is most closely related to cardiovascular disease (CVD risk factors in an Iranian urban population. METHODS: This cross-sectional study was conducted with 991 men and 1188 women aged 15 to 64 years. Body mass index (BMI, waist circumference (WC, waist-to-hip ratio (WHR, waist-to-height ratio (WHtR and percentage of body fat were measured. A fasting blood specimen was obtained. CVD risk factors, including fasting blood glucose, triglycerides, total cholesterol (Tchol, low-density (LDL-C and high-density-lipoprotein cholesterol (HDL-C were assessed. RESULTS: Based on BMI, more than 49% of men and 53% of women were either overweight or obese with 10.2% of men and 18.6% of women being obese. In both men and women, the prevalence of overweight was greater among 40-49 year olds and the prevalence of obesity was greater among those 50+ years. Using the multiple regression analysis, BMI, WHtR and WHR explained the highest percentage of variation of triglycerides, Tchol/HDL-C ratio and LDL-C in men, respectively, whereas WHR explained the highest percentage of variation of triglycerides and WC explained the highest percentage of variation of Tchol/HDL-C ratio and LDL-C in women. CONCLUSION: Our data indicated that WHR and WHtR were the anthropometric indicators that best predicted CVD risk factors in men and WHR and WC in women.

  3. ANTHROPOMETRICAL PROFILE AND BIO-MOTOR ABILITIES OF YOUNG ELITE WRESTLERS

    Directory of Open Access Journals (Sweden)

    Ali Jafari Rahmat

    2016-12-01

    Full Text Available Aim: This study investigated the association between motor performance and somatic type, anthropometric, body composition, physiologic and physical fitness profile in young wrestlers. Material: 16 young wrestlers aging 16-19 with a 4-year-experience of taking part in national championships were selected for the study. Following the standard methods in the testing center of Alborz province some tests like aerobic power, muscular endurance, flexibility and agility speed tests and 1RM were taken to integrate the participants. Also, it should be noted that the participants’ height, weight, the girth of thigh, elbow, calf and arm and skin thickness were measured. Results: Somatotype, Somatotype Attitudinal Distance (SAD, Height Weight ratio (HWR were calculated according to Carter and Heath anthropometric method. Body Fat Percentage (%BF, HWR and SAD resulted in 10.90±1.64, 43.27±0.87 and 0.94±0.87 respectively. Somatotype Standard Deviation and mean regarding endomorphic, mesomorphic and ectomorphic components were 2.16±0.46, 5.20±0.77 and 2.88±0.64 respectively. Physiologically, wrestlers VO2MAX (kg/min were 49.31±4.22 and their Resting Heart Rate (bpm were 68.31±6.64. Conclusion: As the present study illustrates, Somatotype of the Endomorphs, Mesomorphs and Ectomorphs were the same. As a result, coaches can plan wrestlers’ training programs and review of techniques based on anthropometric and physiologic data driven from their sports performances.Besides, wrestlers could be well-informed about their performance. Moreover, aforesaid information could be beneficial to wrestling federations and all other organizations contributing the wrestling federation while holding talent identification programs and recognizing young wrestlers.

  4. Effect of measurement conditions on three-dimensional roughness values, and development of measurement standard

    International Nuclear Information System (INIS)

    Fabre, A; Brenier, B; Raynaud, S

    2011-01-01

    Friction or corrosion behaviour, fatigue lifetime for mechanical components are influenced by their boundary and subsurface properties. The surface integrity is studied on mechanical component in order to improve the service behaviour of them. Roughness is one of the main geometrical properties, which is to be qualified and quantified. Components can be obtained using a complex process: forming, machining and treatment can be combined to realize parts with complex shape. Then, three-dimensional roughness is needed to characterize these parts with complex shape and textured surface. With contact or non-contact measurements (contact stylus, confocal microprobe, interferometer), three-dimensional roughness is quantified using the calculation of pertinent parameters defined by the international standard PR EN ISO 25178-2:2008. An analysis will identify the influence of measurement conditions on three-dimensional parameters. The purpose of this study is to analyse the variation of roughness results using contact stylus or optical apparatus. The second aim of this work is to develop a measurement standard well adapted to qualify the contact and non-contact apparatus.

  5. Effect of measurement conditions on three-dimensional roughness values, and development of measurement standard

    Energy Technology Data Exchange (ETDEWEB)

    Fabre, A; Brenier, B [Arts et Metiers ParisTech, MecaSurf Laboratory, 2, Cours des Arts et Metiers, 13617 Aix-en-Provence (France); Raynaud, S, E-mail: agnes.fabre@ensam.eu [INSA Lyon, MIP2 Laboratory, 27 Avenue Jean Capelle, Bat Jacquard, 69100 Villeurbanne (France)

    2011-08-19

    Friction or corrosion behaviour, fatigue lifetime for mechanical components are influenced by their boundary and subsurface properties. The surface integrity is studied on mechanical component in order to improve the service behaviour of them. Roughness is one of the main geometrical properties, which is to be qualified and quantified. Components can be obtained using a complex process: forming, machining and treatment can be combined to realize parts with complex shape. Then, three-dimensional roughness is needed to characterize these parts with complex shape and textured surface. With contact or non-contact measurements (contact stylus, confocal microprobe, interferometer), three-dimensional roughness is quantified using the calculation of pertinent parameters defined by the international standard PR EN ISO 25178-2:2008. An analysis will identify the influence of measurement conditions on three-dimensional parameters. The purpose of this study is to analyse the variation of roughness results using contact stylus or optical apparatus. The second aim of this work is to develop a measurement standard well adapted to qualify the contact and non-contact apparatus.

  6. Classroom furniture and anthropometric characteristics of Iranian high school students: proposed dimensions based on anthropometric data.

    Science.gov (United States)

    Dianat, Iman; Karimi, Mohammad Ali; Asl Hashemi, Ahmad; Bahrampour, Samira

    2013-01-01

    The study evaluated the potential mismatch between classroom furniture dimensions and anthropometric characteristics of 978 Iranian high school students (498 girls, 480 boys), aged 15-18 years. Nine anthropometric measurements (stature, sitting height, sitting shoulder height, popliteal height, hip breadth, elbow-seat height, buttock-popliteal length, buttock-knee length and thigh clearance) and five dimensions from the existing classroom furniture were measured and then compared together (using match criterion equations) to identify any potential mismatch between them. The results indicated a considerable mismatch between body dimensions of the students and the existing classroom furniture, with seat height (60.9%), seat width (54.7%) and desktop height (51.7%) being the furniture dimensions with a higher level of mismatch. The levels of mismatch varied between the high-school grade levels and between genders, indicating their special requirements and possible problems. The proposed dimensions of the classroom furniture more appropriate for the students were given. This additional information on students' anthropometry can be used by local furniture industries as a starting point for designing more appropriate furniture for school children, or used by schools to aid in furniture selection. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  7. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  8. Body image and anthropometric indicators in adolescents living with HIV

    Directory of Open Access Journals (Sweden)

    Luiz Rodrigo Augustemak de Lima

    2018-03-01

    Full Text Available The aim of this study was to compare body image and anthropometric indicators among adolescents living with HIV and healthy adolescents (control group. In addition, we verified the associations of anthropometric indicators, infection/treatment, sexual maturity, and sociodemographic characteristics with body image in adolescents living with HIV. One hundred and eleven adolescents aged 10 to 15 years were divided into those living with HIV (n = 57 and a control group (n = 54. Body image was investigated using an eight-point body silhouette scale. Body weight, height, circumferences, and skinfolds were measured. Body image dissatisfaction was found in 54.4% of the adolescents living with HIV, with 38.6% of them wishing to increase their body size. Conversely, body image dissatisfaction was due to the desire to reduce body size in the control group (40.7%. No difference between the HIV and control groups was found for the anthropometric indicators analyzed. Gender (β = -0.52, age (β = 0.18, body weight (β = 0.07, body mass index (β = -0.19, and upper arm muscle area (β = -0.08 explained 42% of the variation in the body image score of adolescents living with HIV. Thinness is the main reason for body image dissatisfaction in adolescents living with HIV. Almost half the body dissatisfaction of adolescents living with HIV was explained by demographic and anthropometric variables.

  9. Static Anthropometric Characteristics of Bangladeshi Vehicle Driver: A Case Study.

    Science.gov (United States)

    Halder, P K; Sarker, E

    2016-01-01

    Background. Inappropriate design of sitting furniture and working equipment causes the serious musculoskeletal injuries and various pains as well as reducing working efficiency. Uncomfortable sitting posture in prolonged driving in Bangladesh is an issue to be solved immediately. Therefore, anthropometric databank of user population is significantly essential for the suitable dimensional design for avoiding these remarkable problems. Methods. This study analyses the anthropometric data of the Bangladeshi male vehicle driver aged between 30 and 60 years. A total of 210 Bangladeshi healthy drivers are considered for 15 anthropometric measurements and compared with the similar anthropometrics of other nationalities. Results. The mean stature and sitting height erect of Bangladeshi driver are 1645 mm and 843 mm, respectively. The mean of body mass index (BMI) of the drivers is 26.09 kg/m(2), which indicates that the drivers are overweight. The mean stature of Bangladeshi driver is 17 mm shorter than the driver of Korea and 115 mm shorter than the driver of Iran. Conclusion. There are substantial differences between the body dimensions of Bangladeshi driver and similar dimensions of other countries. In comparison, Bangladeshi driver is found to be the shortest compared with the sample of other nationalities.

  10. Some anthropometric and functional dimensions of the pygmy (Kivu Twa).

    Science.gov (United States)

    Ghesquiere, J L; Karvonen, M J

    1981-01-01

    At the Institut pour la Recherche Scientifique en Afrique Centrale (I.R.S.A.C.), Station of Lwiro on Lake Kivu, Republic of Zaire, anthropometric and spirometric measurements were made on 25 male members of a pygmy clan, living the traditional hunter-gatherer's life on the slopes of the Mitumba mountain range. The response of 15 men to graded exercise was tested on a bicycle ergometer. The morphology of the Kivu Twa was in agreement with that described for pygmies in the same general area. Blood pressure was extremely low, 99/64 (SD +/- 12/11) mm Hg, and was not affected by age. Lung volumes were small compared to those of Europeans, and fitted well the standards for the 'Bantu' in South Africa. The vital capacity of adult men was 3.183 (SD +/- 0.151)l and the one-second forced expiratory volume 2.558 (SD +/- 0.11)l. Their cardiovascular response to increasing physical work-loads was similar to that of other population samples in Central Africa and quite close to those of the Equator Twa. The maximum aerobic power, calculated indirectly, was small, 1.957 (SD +/- 0.158)l/min, but when expressed per kg body weight was 42.5 (SD +/- 5.2) ml min-1 kg-1, comparable to that of many other populations.

  11. Evaluating accuracy of structural geometry by DXA methods with an anthropometric proximal femur phantom.

    Science.gov (United States)

    Khoo, B C C; Beck, T J; Brown, K; Price, R I

    2013-09-01

    DXA-derived bone structural geometry has been reported extensively but lacks an accuracy standard. In this study, we describe a novel anthropometric structural geometry phantom that simulates the proximal femur for use in assessing accuracy of geometry measurements by DXA or other X-ray methods. The phantom consists of seven different interchangeable neck modules with geometries that span the range of dimensions in an adult human proximal femur, including those representing osteoporosis. Ten repeated hip scans of each neck module using two current DXA scanner models were performed without repositioning. After scanner specific calibration, hip structure analysis was used to derive structural geometry. Scanner performance was similar for the two manufacturers. DXA-derived HSA geometric measurements were highly correlated with values derived directly from phantom geometry and position; R² between DXA and phantom measures were greater than 94% for all parameters, while precision error ranged between 0.3 and 3.9%. Despite high R² there were some systematic geometry errors for both scanners that were small for outer diameter, but increasing with complexity of geometrical parameter; e.g. buckling ratio. In summary, the anthropometric phantom and its fabrication concept were shown to be appropriate for evaluating proximal femoral structural geometry in two different DXA systems.

  12. The Standardization of Bra Cup Measurements: Redefining Bra Sizing Language.

    Science.gov (United States)

    Bengtson, Bradley P; Glicksman, Caroline A

    2015-10-01

    There are many challenges in developing a standardized bra cup system, the most significant being that bra cup sizes are a continuum. Women's breasts occur as a fluid range of shapes, sizes, and volumes. Patients have specific expectations regarding bra cup size, and failure to achieve expectations remains the leading cause of patient dissatisfaction. Implant selection that determines eventual bra cup size is critical in patient education and management of patient expectations; however, this is not achievable until all speak the same bra cup language. Patient and surgeon perceptions may never be exact, but it is important to establish guidelines and standards to bridge this gap. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Biopolitcs and education. Measurement, standardization and regularisation of the population

    Directory of Open Access Journals (Sweden)

    Geo SAURA

    2015-12-01

    Full Text Available This paper analyzes scholar standardized testing as a dispositif of educational biopolitics. It describes a theoretical review of biopolitics, an analytic of power of the economic agencies that legitimize global education policies and a socio- technical mapping of teacher control technologies. The dispositif of educational biopolitics causes the legitimizing of disciplinary logic in students, along with the perpetuation of dividing lines (normality/abnormality and the hegemony of standardization as regularization of population sets. The effects brought about in teachers are presented with in-depth interviews of empirical research, including two qualities: «comparability», of which the characteristics are computing/center and relationship with everything, and «dividuality» where the properties are competitiveness and subjection.

  14. Assessment of undernutrition among children below 5, using Composite Index of Anthropometric Failure (CIAF

    Directory of Open Access Journals (Sweden)

    Garima Gupta

    2017-03-01

    Full Text Available Background: SDG 2.2 aims to end all forms of malnutrition by 2030. Weight for age estimate misses out chronic and acute on chronic malnutrition. An aggregate indicator-the Composite Index of Anthropometric Failure (CIAF can help in addressing this concern. Aim & Objective: To assess the nutritional status of under five children using CIAF and compare it with other indices. Material & Methods: A cross-sectional, descriptive study was conducted in a resettlement colony of Delhi, between June to July 2015. Anthropometric measurements were taken using standard operative procedures. Mothers of the study children were interviewed to obtain relevant information. Z scores were calculated using WHO-ANTHRO software. Nutritional status indicators were determined as per the World Health Organization 2006 child growth standards. Results: A total of 100 under-5 children were assessed. The prevalence of CIAF was 62% in our study. 35% of children were found to be underweight, 25% were wasted and 43% stunted. Mid Upper Arm Circumference detected 58.5% as undernourished. Using weight-for-age criterion for identifying undernourished children led to underestimation of the prevalence by 27%. Conclusion: CIAF can be used to provide a single, aggregated assessment of undernutrition. Use of this tool by field level workers will improve the diagnosis of undernutrition and help in early initiation of treatment.

  15. Impact of urbanization on obesity, anthropometric profile and blood pressure in the Igbos of Nigeria.

    Science.gov (United States)

    Ekezie, Jervase; Anyanwu, Emeka G; Danborno, Barnabas; Anthony, Ugochukwu

    2011-05-01

    Hypertension in developing setting is often attributed to westernization of life style and stresses of urbanization, some of these increases have been noted in Nigeria. This is a study on rural-urban differences on the blood pressure, obesity and anthropometrics among a major ethnic group in Nigeria. A total of 325 men and 242 women aged 20 to 80 years, of the Igbo ethnicity were selected for this study. The samples were selected from the rural and urban subgroups of the Igbo population. Systolic and diastolic blood pressure, body mass index, waist- hip ratio, waist-height ratio, waist circumference, triceps, subscapular, calf and sum of the three skin fold thicknesses and other anthropometric measurements were obtained using standard procedures. Blood pressure correlated with age and most of the anthropometric parameters (pblood pressure indicators were higher in the urban than in the rural sample. Women showed higher predisposition to both general and abdominal obesities in both samples. High blood pressure occurred more often in the urban sample than the rural. Urban men had the highest mean blood pressure (pHigh blood pressure appeared much connected with the pressures of city life. Regression formulae were derived for all the adiposity measures of Igbos in both rural and urban locations. High rates of obesity and hypertension are noted among Igbos in both rural and urban areas. This is especially in the urban setting. The finding is indicative of a low level of attention on hypertension and obesity in the Igbos. The data reported here call for intervention programs on the risks, preventions and management of obesity and obesity related conditions.

  16. Practical estimation of the uncertainty of analytical measurement standards

    NARCIS (Netherlands)

    Peters, R.J.B.; Elbers, I.J.W.; Klijnstra, M.D.; Stolker, A.A.M.

    2011-01-01

    Nowadays, a lot of time and resources are used to determine the quality of goods and services. As a consequence, the quality of measurements themselves, e.g., the metrological traceability of the measured quantity values is essential to allow a proper evaluation of the results with regard to

  17. Standard guide for making quality nondestructive assay measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This guide is a compendium of Quality Measurement Practices for performing measurements of radioactive material using nondestructive assay (NDA) instruments. The primary purpose of the guide is to assist users in arriving at quality NDA results, that is, results that satisfy the end user’s needs. This is accomplished by providing an acceptable and uniform basis for the collection, analysis, comparison, and application of data. The recommendations are not compulsory or prerequisites to achieving quality NDA measurements, but are considered contributory in most areas. 1.2 This guide applies to the use of NDA instrumentation for the measurement of nuclear materials by the observation of spontaneous or stimulated nuclear radiations, including photons, neutrons, or the flow of heat. Recommended calibration, operating, and assurance methods represent guiding principles based on current NDA technology. The diversity of industry-wide nuclear materials measurement applications and instrumentation precludes disc...

  18. Atlantooccipital junction: standards for measurement in normal children.

    Science.gov (United States)

    Kaufman, R A; Carroll, C D; Buncher, C R

    1987-01-01

    This study describes a simple method for measuring the distance between the occiput and atlas when a distraction-dislocation injury is suspected in a child. Measurements were made at five evenly spaced locations along the atlantooccipital joint on cross-table lateral skull radiographs in 100 normal children. These data were compared with similar measurements in eight patients with proved atlantooccipital dislocation. The mean normal measurement fell between 1.96-2.63 mm for all five points. For boys or girls aged 1-15 years, the normal distance should not exceed 5 mm at any point in the joint. The likelihood that any normal child will have a measurement greater than or equal to 4.5 mm at any point is between 0.4-5.85% (expected false-positive rate).

  19. Measurement standards and the general problem of reference points in chemical analysis

    International Nuclear Information System (INIS)

    Richter, W.; Dube, G.

    2002-01-01

    Besides the measurement standards available in general metrology in the form of the realisations of the units of measurement, measurement standards of chemical composition are needed for the vast field of chemical measurement (measurements of the chemical composition), because it is the main aim of such measurements to quantify non-isolated substances, often in complicated matrices, to which the 'classical' measurement standards and their lower- level derivatives are not directly applicable. At present, material artefacts as well as standard measurement devices serve as chemical measurement standards. These are measurement standards in the full metrological sense only, however, if they are firmly linked to the SI unit in which the composition represented by the standard is expressed. This requirement has the consequence that only a very restricted number of really reliable chemical measurement standards exist at present. Since it is very difficult and time consuming to increase this number substantially and, on the other hand, reliable reference points are increasingly needed for all kinds of chemical measurements, primary methods of measurement and high-level reference measurements will play an increasingly important role for the establishment of worldwide comparability and hence mutual acceptance of chemical measurement results. (author)

  20. Standards for measurements and testing of wind turbine power quality

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, P. [Risoe National Lab., Roskilde (Denmark); Gerdes, G.; Klosse, R.; Santjer, F. [DEWI, Wilhelmshaven (Germany); Robertson, N.; Davy, W. [NEL, Glasgow (United Kingdom); Koulouvari, M.; Morfiadakis, E. [CRES, Pikermi (Greece); Larsson, Aa. [Chalmers Univ. of Technology, Goeteborg (Sweden)

    1999-03-01

    The present paper describes the work done in power quality sub-task of the project `European Wind Turbine Testing Procedure Developments` funded by the EU SMT program. The objective of the power quality sub-task has been to make analyses and new recommendation(s) for the standardisation of measurement and verification of wind turbine power quality. The work has been organised in three major activities. The first activity has been to propose measurement procedures and to verify existing and new measurement procedures. This activity has also involved a comparison of the measurements and data processing of the participating partners. The second activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with constant rotor speed. The third activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with variable rotor speed. (au)

  1. Standardized voluntary force measurement in a lower extremity rehabilitation robot

    OpenAIRE

    Bolliger, M; Banz, R; Dietz, V; Lünenburger, L

    2008-01-01

    Abstract Background Isometric force measurements in the lower extremity are widely used in rehabilitation of subjects with neurological movement disorders (NMD) because walking ability has been shown to be related to muscle strength. Therefore muscle strength measurements can be used to monitor and control the effects of training programs. A new method to assess isometric muscle force was implemented in the driven gait orthosis (DGO) Lokomat. To evaluate the capabilities of this new measureme...

  2. Measuring enzyme activities under standardized in vivo-like conditions for Systems Biology

    NARCIS (Netherlands)

    van Eunen, K.; Bouwman, J.; Daran-Lapujade, P.A.L.; Postmus, J.; Canelas, A.; Mensonides, F.I.C.; Orij, R.; Tuzun, I.; van der Brink, J.; Smits, G.J.; van Gulik, W.M.; Brul, S.; Heijnen, J.J.; de Winde, J.H.; Teixeira de Mattos, M.J.; Kettner, C.; Nielsen, J.; Westerhoff, H.V.; Bakker, B.M.

    2010-01-01

    Realistic quantitative models require data from many laboratories. Therefore, standardization of experimental systems and assay conditions is crucial. Moreover, standards should be representative of the in vivo conditions. However, most often, enzyme-kinetic parameters are measured under assay

  3. Measuring enzyme activities under standardized in vivo-like conditions for systems biology

    NARCIS (Netherlands)

    van Eunen, Karen; Bouwman, Jildau; Daran-Lapujade, Pascale; Postmus, Jarne; Canelas, Andre B.; Mensonides, Femke I. C.; Orij, Rick; Tuzun, Isil; van den Brink, Joost; Smits, Gertien J.; van Gulik, Walter M.; Brul, Stanley; de Winde, Johannes H.; de Mattos, M. J. Teixeira; Kettner, Carsten; Nielsen, Jens; Westerhoff, Hans V.; Bakker, Barbara M.; Heijnen, J.J.

    Realistic quantitative models require data from many laboratories. Therefore, standardization of experimental systems and assay conditions is crucial. Moreover, standards should be representative of the in vivo conditions. However, most often, enzyme-kinetic parameters are measured under assay

  4. The sensitivity of standard radiographic foot measures to misalignment.

    Science.gov (United States)

    Willauer, Patrick; Sangeorzan, Bruce J; Whittaker, Eric C; Shofer, Jane B; Ledoux, William R

    2014-12-01

    The purpose of this study was to identify the effects that X-ray source misalignment has on common measurements made from anterior-poster (AP) and medial-lateral (ML) view foot radiographs. A cadaveric foot model was used to obtain ML radiographs with ±25 degree transverse plane misalignment. From these images the calcaneal pitch angle (CPA) and lateral talometatarsal angle (LTMA) were measured. AP images were captured with up to 30 degree sagittal plane misalignment as well as ±15 degree misalignment in the transverse plane at each sagittal angle. From these images the talonavicular coverage angle (TNCA) and talometatarsal angle (TMA) were measured. On the ML images, the CPA was sensitive to transverse plane misalignment from -10 to -25 degrees and from 15 to 25 degrees (P plane misalignment. On the AP images, the TNCA and TMA were not sensitive to sagittal plane misalignment alone. However, at 0, 10, and 15 degrees sagittal misalignment the TNCA showed sensitivity to transverse plane misalignment (P foot radiographic parameters, especially the CPA when there is transverse plane misalignment and the TNCA when there is both sagittal and transverse plane misalignment. The LTMA and TMA can be measured reliably, even with significant misalignment present. If a researcher or clinician is interested in measuring the CPA or TNCA, the current best practices guidelines for obtaining ML and AP images should be closely followed. © The Author(s) 2014.

  5. Standardized voluntary force measurement in a lower extremity rehabilitation robot.

    Science.gov (United States)

    Bolliger, Marc; Banz, Raphael; Dietz, Volker; Lünenburger, Lars

    2008-10-28

    Isometric force measurements in the lower extremity are widely used in rehabilitation of subjects with neurological movement disorders (NMD) because walking ability has been shown to be related to muscle strength. Therefore muscle strength measurements can be used to monitor and control the effects of training programs. A new method to assess isometric muscle force was implemented in the driven gait orthosis (DGO) Lokomat. To evaluate the capabilities of this new measurement method, inter- and intra-rater reliability were assessed. Reliability was assessed in subjects with and without NMD. Subjects were tested twice on the same day by two different therapists to test inter-rater reliability and on two separate days by the same therapist to test intra-rater reliability. Results showed fair to good reliability for the new measurement method to assess isometric muscle force of lower extremities. In subjects without NMD, intraclass correlation coefficients (ICC) for inter-rater reliability ranged from 0.72 to 0.97 and intra-rater reliability from 0.71 to 0.90. In subjects with NMD, ICC ranged from 0.66 to 0.97 for inter-rater and from 0.50 to 0.96 for intra-rater reliability. Inter- and intra- rater reliability of an assessment method for measuring maximal voluntary isometric muscle force of lower extremities was demonstrated. We suggest that this method is a valuable tool for documentation and controlling of the rehabilitation process in patients using a DGO.

  6. Mother's age effect on the boys' anthropometric properties in the Region of Tuzla (Bosnia and Herzegovina).

    Science.gov (United States)

    Hadzihalilović, Jasminka; Hadziselimović, Rifat; Halilović, Amir H; Osmić, Munevera; Hamidović, Hajrija; Ahmić, Adisa; Jusupović, Fatima

    2004-12-01

    Our objective was to establish if mother's age affects the anthropometric properties their 11 and 16 years old sons, and if the boys' BMI is satisfactory. Cross-sections, questionnaires, and statistics were used for data processing BMI (kg/m2) was presented according to the scale Quetelet's index nutritional status. Twelve anthropometric properties were researched. It was established that mother's age affects anthropometric properties in adolescent boys. The younger mothers' boys come to puberty with significantly higher mean values for most anthropometric parameters. In the course of adolescent jump, older mothers' boys have significantly higher anthropometric measures in comparison to their age boys delivered by younger mothers. After the completion of their intensive growth and development anthropometric measures in both category boys are equal or insignificantly higher in younger mothers' sons. Mother's age affects their sons' anthropometric properties of growth and development, particularly in prepuberty and puberty. After puberty that effect is not significant. According to BMI, the boys coming from the researched region make the group of underfed children. That is probably the outcome of bad living conditions, irregular and insufficient diet, stress, etc. in the course of four year aggression on Bosnia and Herzegovina.

  7. Anthropometric Indices Added the Predictive Ability of Iron Status in Prognosis of Atherosclerosis

    Directory of Open Access Journals (Sweden)

    Motahar Heidari-Beni

    2012-12-01

    Full Text Available Background: Abnormal homeostasis of iron such as deficiency or overload is associated with the pathogenesis of cardiovascular disease (CVD. Another risk factor for CVD is obesity whose added predictive ability to iron status has been assessed by few study. This study aimed to eva-luate the effect of adding anthropometric indices to a model based on iron status as risk factors of CVD.Methods: This cross-sectional study included 140 adult women aged 18-50 years randomly se-lected from Sheikhorrais Clinic that is one of the Tabriz University sub-specialized clinics in 2011. Anthropometric indices, carotid intima-media thickness (CIMT and body iron status were measured by standard protocol, non-invasive ultrasound and concentrations of serum iron, ferri-tin, TIBC (Total iron Binding Capacity and complete blood cell counts (CBC, respectively. In-tegrated discriminatory improvement index (IDI and net reclassification improvement index (NRI were used as the measures of added predictive ability of anthropometric measures to the iron statues.Results: IDI (SE after adding Waist Circumference (WC, Waist to Heap Ratio (WHR, Waist to Height Ratio (WHtR, Body Mass Index (BMI and Body fat (% to base model was 0.12 (0.028, 0.09 (0.026, 0.12 (0.028, 0.07 (0.022 and 0.10 (0.026 respectively. The NRI (SE was 0.10 (0.065 for WC, 0.03 (0.058 for WHR, 0.07 (0.067 for WHtR, 0.05 (0.067 for BMI, and 0.08 (0.064 for Body fat.Conclusions: Anthropometric indices could significantly add to the predictive ability of the iron statues, with highest IDI when WC and WHtR were added to the base model. It suggests that by adding WC and WHtR to the iron status lead us to a more optimal model for predicting the ini-tial stage of atherosclerosis.

  8. Advisory Committee for the Calibration Standards of Ionizing Radiation Measurement: Section 3. Neutron measurements

    International Nuclear Information System (INIS)

    1982-01-01

    Section III (Mesures neutroniques) of the Comite Consultatif pour les Etalons de Mesure des Rayonnements Ionisants held its fifth meeting in May 1981. Recent work carried out at BIPM in the field of neutron measurements was reported. The status of a full-scale 252 Cf neutron source intercomparison (10 7 s - 1 ) and of several restricted comparisons was discussed. Intercomparisons of fast neutron fluence rates are in progress ( 115 In(n,n') 115 Insup(m); NB/Zr) or will take place in the near future ( 115 n(n,#betta#) 116 Insup(m); 235 U and 238 U fission chambers). An intercomparison of neutron dosimetry standards by circulating tissue-equivalent ion chambers will be prepared and organized by BIPM. Finally, there was a broad exchange of information on work in progress at the various laboratories represented at the meeting [fr

  9. Various approaches to standardization and the importance of measurement accuracy

    NARCIS (Netherlands)

    Gram, J.; Jespersen, J.; Kluft, C.; Declerck, P.

    1996-01-01

    Biochemical measurements of quantities, i.e. analytes, of the haemostatic system are the basis of evaluating patients with potentially serious or lifethreatening disorders. Therefore, there is a need of a high level of certainty of the results. Experience based on the comprehensive international

  10. Concurrent Validity of Standardized Measures of Written Expression.

    Science.gov (United States)

    Riccio, Cynthia A.; Boan, Candace H.; Staniszewski, Deborah; Hynd, George W.

    1997-01-01

    A study involving 120 school-aged children that investigated the concurrent validity of measures of written language found that the Wechsler Individual Achievement Test Written Expression subtest correlates moderately with the Written Expression subtest of the Peabody Individual Achievement Test-Revised and the Spontaneous Writing Quotient of the…

  11. Conditional Standard Errors of Measurement for Composite Scores Using IRT

    Science.gov (United States)

    Kolen, Michael J.; Wang, Tianyou; Lee, Won-Chan

    2012-01-01

    Composite scores are often formed from test scores on educational achievement test batteries to provide a single index of achievement over two or more content areas or two or more item types on that test. Composite scores are subject to measurement error, and as with scores on individual tests, the amount of error variability typically depends on…

  12. The effect of two nutritional methods in changes of anthropometric indexes in obese parents and their children

    Directory of Open Access Journals (Sweden)

    Firoozeh Sajjadi

    2011-03-01

    Full Text Available Background: Parents obesity has a direct relation with their children obesity. The aim of this study is to determine the effect of two methods of weight loss in obese parents and their children. Materials and Method: We conducted a randomized clinical trial. It was performed among 60 parents with obesity or overweight that referred to cardiovascular research center of Isfahan to control their children obesity in 2005-2007. They were divided into two groups and followed up for one year. The first group received diet with calorie restriction and the second group received food recommendation without calorie restriction according to the World Health Organization dietary guideline. Anthropometric characteristics such as body max index (BMI, waist circumference, waist to hip ratio were measured using standard methods. Data were analyzed by paired and independent t-tests.Results: There was a significant difference in the mean of BMI in children who received diet recommendation (p=0.01 before and after trial. There was no significant difference in mean changes of anthropometric characteristics in parents, before and after receiving diet and diet recommendation.Conclusion: Family education and supporting may play an effective role on controlling children weight. Decreased anthropometric characteristics showed that healthy food recommendations can be effective on weight loss as well as diet prescription

  13. Standardizing measurement, sampling and reporting for public exposure assessments

    Energy Technology Data Exchange (ETDEWEB)

    Rochedo, Elaine R.R. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/No. CEP 22780-160 Rio de Janeiro, RJ (Brazil)], E-mail: elaine@ird.gov.br

    2008-11-15

    UNSCEAR assesses worldwide public exposure from natural and man-made sources of ionizing radiation based on information submitted to UNSCEAR by United Nations Member States and from peer reviewed scientific literature. These assessments are used as a basis for radiation protection programs of international and national regulatory and research organizations. Although UNSCEAR describes its assessment methodologies, the data are based on various monitoring approaches. In order to reduce uncertainties and improve confidence in public exposure assessments, it would be necessary to harmonize the methodologies used for sampling, measuring and reporting of environmental results.

  14. Anthropometric and physical fitness characteristics of young male soccer players

    Directory of Open Access Journals (Sweden)

    Leslie Andrews Portes

    2010-06-01

    Full Text Available The objective of this study was to determine anthropometric and physical fitnesscharacteristics of Brazilian male children and adolescents at the beginning of soccer training. Inthis study, 282 male soccer players ranging in age from 10 to 13 years were evaluated. The athletesparticipated in a formal soccer training program 3 times per week, with each training lasting 3hours. Anthropometric and physical fitness parameters were obtained. The boys were divided intoage classes and prevalence data were analyzed using Pearson’s chi-square test. Parametric datawere compared by one-way ANOVA or the Kruskal-Wallis test, when necessary. The resultsare expressed as the mean ± standard deviation and a p value <0.05 was considered to be significant.Growth, development, body adiposity and physical fitness characteristics were adequateand proportional to age among the boys studied (p<0.05. It was concluded that anthropometricand physical fitness characteristics of young male elite soccer players improve with and areproportional to age. Children and adolescents greatly benefit from regular physical activity. Thepresent results show that young male soccer players present adequate anthropometric conditionsand physical fitness prior to the initiation of formal training at soccer clubs.

  15. Evaluation of Anthropometric Indices of Patients with Left Ventricle Dysfunction Fallowing First Acute Anterior Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Rasoul Azarfarin

    2012-02-01

    Full Text Available Introduction: In the current study, we evaluated the effect of anthropometric indices on ejection fraction following first acute anterior myocardial infarction. Methods: In an analytic-cross sectional study, 50 patients with acute anterior myocardial infarction and abnormal anthropometric indices (Body Mass Index (BMI ≥ 30, Waist Hip Ratio (WHR ≥ 1 and ≥ 0.85 in males and females respectively and Waist Circumference (WC ≥ 102 cm and ≥ 88 cm in males and females respectively were recruited as case group and 50 patients with acute anterior myocardial infarction and normal anthropometric indices as control group. Subsequently, the relation between anthropometric indices and left ventricle dysfunction was evaluated and compared between two groups. Results: 77 peopleof the studied patients were male and 23 female with the mean age of 59± 1.2 years and an age range of 32-90 years. To evaluate the left ventricle function, the mean ejection fraction of the patients was measured as 34.3± 7.2 % and 44.8± 6.3% in patients withabnormal anthropometric indices and patients with normal anthropometric indices respectively (P= 0.0001. Calculation of the correlation coefficient between ejection fraction and BMI, WHR and WC in males and females revealed a moderate reverse (r=-0.521 tor=-0.691 and statistically significant (P= 0.0001 relations which was of more strength in females. Conclusion: Anthropometric indices including BMI and waist circumference influence cardiac function following myocardial infarction.

  16. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  17. Nutritional Status and Anthropometric Indices in High School Girls in Ilam, West Iran

    Directory of Open Access Journals (Sweden)

    Fatemeh Jamalikandazi

    2016-01-01

    Full Text Available Background. Adolescence is one of the most challenging periods for human growth and nutritional status. The aim of this study was to assess the nutritional status and anthropometric indices in high school girls in Ilam. Methods. This cross-sectional study was performed on 360 domestic high school girl students chosen randomly by cluster sampling. Data were gathered through interviews performed by a dietitian to fill 24-hour dietary recall and food frequency and demographic questionnaires. Then we performed the anthropometric measurements and we compared the results with CDC2000 standards. We analyzed our data by N4 food analyzer and SPSS16 software. Results. The prevalence of obesity and overweight was 5% and 10.8%, respectively. Simultaneously, the prevalence of underweight was 20.2%. The prevalence of stunting was 5.8%. We also showed that 50% of high school girls in Ilam suffered from severe food insecurity, 14.7% suffered from mild insecurity, and 4.7% get extra energy from foods. Food analysis showed that micronutrients such as zinc, iron, calcium, folate, fiber, magnesium, and vitamin B12 were less than what is recommended by the RDA. Conclusion. Undernutrition and overnutrition are completely prevalent among girls studied in Ilam. This needs further acts and investigations in the field and more nutritional and health educations.

  18. The relationships between renal compensatory hypertrophy etiologic factors and anthropometric development in the pediatric age group.

    Science.gov (United States)

    Alaygut, Demet; Soylu, Alper; Kasap, Belde; Türkmen, Mehmet; Cakmakcı, Handan; Kavukcu, Salih

    2013-08-01

    To evaluate the factors associated with compensatory hypertrophy in the functional kidneys of children. The medical files of patients with a solitary functional kidney were reviewed retrospectively. Data regarding anthropometric measurements, functional renal length, functional renal length of standard deviation score (SDS) of functional kidney at diagnosis, and end of follow-up were obtained. Patients were divided into 2 groups, those with a unilateral kidney function of atrophy, group 1) and those with a solitary kidney (agenesis, and multicystic dysplastic kidney, group 2). A total of 126 patients (70 boys) were evaluated. Both the sizes of the functional kidney and functional kidney SDS values at diagnosis were greater in group 1 relative to group 2. At the end of the follow-up period, anthropometric values including functional kidney size were higher in group 2. Functional kidney size of 2 SDS above the normal was mostly predictive at age 17.5 months (odds ratio [OR] 5.06) and at a body height of 82 cm (OR 5.57). The most determining factors for renal length SDS values were age and height. Solitary kidneys complete compensatory hypertrophy by 17.5 months of age, and after that their growth continues in parallel to normal growth. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Young swimmers' classification based on kinematics, hydrodynamics, and anthropometrics.

    Science.gov (United States)

    Barbosa, Tiago M; Morais, Jorge E; Costa, Mário J; Goncalves, José; Marinho, Daniel A; Silva, António J

    2014-04-01

    The aim of this article has been to classify swimmers based on kinematics, hydrodynamics, and anthropometrics. Sixty-seven young swimmers made a maximal 25 m front-crawl to measure with a speedometer the swimming velocity (v), speed-fluctuation (dv) and dv normalized to v (dv/v). Another two 25 m bouts with and without carrying a perturbation device were made to estimate active drag coefficient (CDa). Trunk transverse surface area (S) was measured with photogrammetric technique on land and in the hydrodynamic position. Cluster 1 was related to swimmers with a high speed fluctuation (ie, dv and dv/v), cluster 2 with anthropometrics (ie, S) and cluster 3 with a high hydrodynamic profile (ie, CDa). The variable that seems to discriminate better the clusters was the dv/v (F=53.680; PPPPv (F=5.375; P=.01). Stepwise discriminant analysis extracted 2 functions: Function 1 was mainly defined by dv/v and S (74.3% of variance), whereas function 2 was mainly defined by CDa (25.7% of variance). It can be concluded that kinematics, hydrodynamics and anthropometrics are determinant domains in which to classify and characterize young swimmers' profiles.

  20. VAT=TAAT-SAAT: innovative anthropometric model to predict visceral adipose tissue without resort to CT-Scan or DXA.

    Science.gov (United States)

    Samouda, Hanen; Dutour, Anne; Chaumoitre, Kathia; Panuel, Michel; Dutour, Olivier; Dadoun, Frédéric

    2013-01-01

    To investigate whether a combination of a selected but limited number of anthropometric measurements predicts visceral adipose tissue (VAT) better than other anthropometric measurements, without resort to medical imaging. Abdominal anthropometric measurements are total abdominal adipose tissue indicators and global measures of VAT and SAAT (subcutaneous abdominal adipose tissue). Therefore, subtracting the anthropometric measurement the more correlated possible with SAAT while being the least correlated possible with VAT, from the most correlated abdominal anthropometric measurement with VAT while being highly correlated with TAAT, may better predict VAT. BMI participants' range was from 16.3 to 52.9 kg m(-2) . Anthropometric and abdominal adipose tissues data by computed tomography (CT-Scan) were available in 253 patients (18-78 years) (CHU Nord, Marseille) and used to develop the anthropometric VAT prediction models. Subtraction of proximal thigh circumference from waist circumference, adjusted to age and/or BMI, predicts better VAT (Women: VAT = 2.15 × Waist C - 3.63 × Proximal Thigh C + 1.46 × Age + 6.22 × BMI - 92.713; R(2) = 0.836. Men: VAT = 6 × Waist C - 4.41 × proximal thigh C + 1.19 × Age - 213.65; R(2) = 0.803) than the best single anthropometric measurement or the association of two anthropometric measurements highly correlated with VAT. Both multivariate models showed no collinearity problem. Selected models demonstrate high sensitivity (97.7% in women, 100% in men). Similar predictive abilities were observed in the validation sample (Women: R(2) = 76%; Men: R(2) = 70%). Bland and Altman method showed no systematic estimation error of VAT. Validated in a large range of age and BMI, our results suggest the usefulness of the anthropometric selected models to predict VAT in Europides (South of France). Copyright © 2013 The Obesity Society.

  1. The misinterpretation of the standard error of measurement in medical education: a primer on the problems, pitfalls and peculiarities of the three different standard errors of measurement.

    Science.gov (United States)

    McManus, I C

    2012-01-01

    In high-stakes assessments in medical education, such as final undergraduate examinations and postgraduate assessments, an attempt is frequently made to set confidence limits on the probable true score of a candidate. Typically, this is carried out using what is referred to as the standard error of measurement (SEM). However, it is often the case that the wrong formula is applied, there actually being three different formulae for use in different situations. To explain and clarify the calculation of the SEM, and differentiate three separate standard errors, which here are called the standard error of measurement (SEmeas), the standard error of estimation (SEest) and the standard error of prediction (SEpred). Most accounts describe the calculation of SEmeas. For most purposes, though, what is required is the standard error of estimation (SEest), which has to be applied not to a candidate's actual score but to their estimated true score after taking into account the regression to the mean that occurs due to the unreliability of an assessment. A third formula, the standard error of prediction (SEpred) is less commonly used in medical education, but is useful in situations such as counselling, where one needs to predict a future actual score on an examination from a previous actual score on the same examination. The various formulae can produce predictions that differ quite substantially, particularly when reliability is not particularly high, and the mark in question is far removed from the average performance of candidates. That can have important, unintended consequences, particularly in a medico-legal context.

  2. Motor abilities and anthropometrics in youth cross-country skiing.

    Science.gov (United States)

    Stöggl, R; Müller, E; Stöggl, T

    2015-02-01

    The purposes were to validate whether general motor abilities and anthropometrics are determinants of youth cross-country (XC) skiing performance; evaluate gender-specific differences; and to establish noninvasive diagnostics. Fifty-one youth XC skiers (34 boys; 13.8 ± 0.6 years and 17 girls; 13.4 ± 0.9 years) performed motor skill and laboratory tests, and anthropometric data were collected and correlated with XC skiing performance. Anthropometrics and maturity status were related to boys but not to girls XC skiing performance. Push-ups and 20-m sprint were correlated to XC skiing performance in both boys and girls. XC skiing performance of boys was predominantly influenced by upper body and trunk strength capacities (medicine ball throw, push-ups, and pull-ups) and jumping power (standing long and triple jump), whereas XC skiing of girls was mainly influenced by aerobic capacities (3000-m run). Laboratory measures did not reveal greater correlations to XC skiing performance compared with simple test concepts of speed, strength, and endurance. Maturity was a major confounding variable in boys but not girls. Use of noninvasive simple test concepts for determination of upper body strength, speed, and endurance represent practicable support for ski clubs, schools, or skiing federations in the guidance and evaluation of young talent, being aware of the effect of maturity especially in boys. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Anthropometric and motor performance profile of elite futsal athletes

    Directory of Open Access Journals (Sweden)

    Ademar Avelar

    2008-07-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2008v10n1p76 The purpose of the present study was to identify the anthropometric and motor performance profi le of futsal (indoor soccer athletes in the second and third-placed teams in the Parana state championships (Brazil. Anthropometric(body mass, stature and skinfolds thickness and motor performance (modified abdominal test, shuttle run, race of 30 m and 40 s measures were obtained from twenty-seven male athletes (24.7 ± 6.4 years; 73.6 ± 7.6 kg; 174.8 ± 6.6 cm. For data analysis, athletes were grouped according to game positions. ANOVA one-way was used for comparisons between different positions, followed by Scheffé’s post hoc test, with p < 0.05. Signifi cant differences were detected in body mass (midfielder < goalkeeper, p < 0.01, stature (midfielder < forward and goalkeeper, p < 0.01 and lean body mass (midfi elder < goalkeeper, p < 0.01. No significant differences in motor performance were detected between the athletes studied. The results of this study show that futsal athletes playing in different positions exhibit similar anthropometric and motor performance, in the majority of variables.

  4. Do anthropometric parameters change the characteristics of snoring sound?

    Science.gov (United States)

    Azarbarzin, Ali; Moussavi, Zahra

    2011-01-01

    Snoring sounds is commonly known to be associated with obstructive sleep apnea (OSA). There are many studies trying to distinguish between the snoring sounds of non-OSA and those of OSA patients. However, OSA is only one of the conditions that affect the structure of upper airway. In this study, we investigated the effect of anthropometric parameters on the snoring sounds. Since snoring sounds are non-Gaussian signals by nature, we derived its Higher Order Statistical (HOS) features and investigated the statistical significance of the anthropometric parameters on each of these features. Data were collected from 40 patients with different levels of OSA. Tracheal respiratory sounds collected by a microphone placed over suprasternal notch, were recorded simultaneously with full-night Polysomnography (PSG) data during sleep. The snoring segments were identified semi-automatically from respiratory sounds using an unsupervised snore detection algorithm. The bispectrum of each SS segment was estimated. We calculated two common HOS measures, Skewness and Kurtosis, plus a new feature called Projected Median Bifrequency (PMBF) from the SS segments. Then, we investigated the statistical relationship between these features and anthropometric parameters such as height, Body Mass Index (BMI), age, gender, and Apnea-Hypopnea Index (AHI). The result showed that gender, BMI, height, and AHI are the parameters that do change the characteristics of snoring sounds significantly.

  5. Analysis and Comparison of Thickness and Bending Measurements from Fabric Touch Tester (FTT and Standard Methods

    Directory of Open Access Journals (Sweden)

    Musa Atiyyah Binti Haji

    2018-03-01

    Full Text Available Fabric Touch Tester (FTT is a relatively new device from SDL Atlas to determine touch properties of fabrics. It simultaneously measures 13 touch-related fabric physical properties in four modules that include bending and thickness measurements. This study aims to comparatively analyze the thickness and bending measurements made by the FTT and the common standard methods used in the textile industry. The results obtained with the FTT for 11 different fabrics were compared with that of standard methods. Despite the different measurement principle, a good correlation was found between the two methods used for the assessment of thickness and bending. As FTT is a new tool for textile comfort measurement and no standard yet exists, these findings are essential to determine the reliability of the measurements and how they relate to the well-established standard methods.

  6. Assessment of anthropometric methods in headset design

    DEFF Research Database (Denmark)

    Stavrakos, Stavros-Konstantinos; Ahmed-Kristensen, Saeema

    2012-01-01

    Current approaches to assess consumer products for usability and comfort often involve expensive user trials. For external ear products such as headsets and bluetooth communication devices comfort is an issue leading to many concepts being rejected at the late stages of the product development...... process once prototypes are developed and tested. Current databases for anthropometric data e.g. Peoplesize Software [Peoplesize 2008] lack data regarding useful ear dimensions of the external ear area. This paper examines the incorporation of anthropometry in the design of external-ear devices, resulting...... in a faster development process and better quality products. Anthropometric dataset have been acquired through existing databases and a series of anthropometric methods performed on population samples. The context of the study is to assess the methods to collect data utilising a case study from the ear...

  7. Standard Test Method for Measuring Heat Flux Using a Water-Cooled Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of a steady heat flux to a given water-cooled surface by means of a system energy balance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. The Czech national long distances measuring standard Koštice - State of play

    Directory of Open Access Journals (Sweden)

    Ladislav Červinka

    2009-11-01

    Full Text Available This article gives information about new Czech national long distances measuring standard, which has been preparedat the distance base near the Koštice village. Submitter of the project is the Czech Office for Standards, Metrology and Testing.Research and document preparation for creation of the measuring standard were ensured by the Research Institute of Geodesy,Topography and Cartography. Interlaboratory comparisons were made by staff of the Bundeswehr University in Munich. The paperreports about works, which will be carried out on national standard in the second half of this year. Purpose of this works is to improvecharacteristics of accuracy of national etalon.

  9. Anthropometric indices of failure to thrive

    Science.gov (United States)

    Raynor, P.; Rudolf, M.

    2000-01-01

    AIMS—To compare five anthropometric methods of classifying failure to thrive in order to ascertain their relative merits in predicting developmental, dietary, and eating problems.
METHODS—The five anthropometric methods were compared in 83 children with failure to thrive.
RESULTS—The methods were inconsistent in classification of severity, and no one method was superior in predicting problems.
CONCLUSIONS—Weight alone, being the simplest, is still the most reasonable marker for failure to thrive and associated problems.

 PMID:10799424

  10. [Evaluation of anthropometric development in patients with enuresis].

    Science.gov (United States)

    Espino, R

    2012-09-01

    An epidemiological study was conducted to assess the anthropometric development in children diagnosed with primary monosymptomatic nocturnal enuresis, depending on the treatment option selected. A longitudinal series of cases including 548 children aged 5-10 years. Anthropometric parameters of children were assessed at diagnosis, and after one and two years of treatment. Children with primary monosymptomatic nocturnal enuresis showed no anthropometric changes when their data were compared to the standard deviation score of height, weight, and body mass index (BMI). Overall, no changes were seen in the above mentioned parameters after two years of treatment for enuresis (except for a weight standard deviation score (SDS) decrease in boys). We only found a decrease in the size and weight in those children undergoing behavioral therapy with or without an alarm, findings that, given the limitations of the study, were not considered significant. The odds ratio for cure after one and two years of treatment was 1.41 (95% CI: 0.85-2.34) and 1.52 (95% CI: 0.86-2.70) for desmopressin (and watchful waiting) as compared to all other options. In this study, children had SDS values of height, weight, and BMI similar to healthy children of the same age and sex before and after treatment for primary monosymptomatic nocturnal enuresis. Desmopressin appeared to increase the probability of cure after one and two years of treatment, however these data should be corroborated in future randomized clinical trials. Copyright © 2011 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  11. Solution standards for quality control of nuclear-material analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.

    1981-01-01

    Analytical chemistry measurement control depends upon reliable solution standards. At the Savannah River Plant Control Laboratory over a thousand analytical measurements are made daily for process control, product specification, accountability, and nuclear safety. Large quantities of solution standards are required for a measurement quality control program covering the many different analytical chemistry methods. Savannah River Plant produced uranium, plutonium, neptunium, and americium metals or oxides are dissolved to prepare stock solutions for working or Quality Control Standards (QCS). Because extensive analytical effort is required to characterize or confirm these solutions, they are prepared in large quantities. These stock solutions are diluted and blended with different chemicals and/or each other to synthesize QCS that match the matrices of different process streams. The target uncertainty of a standard's reference value is 10% of the limit of error of the methods used for routine measurements. Standard Reference Materials from NBS are used according to special procedures to calibrate the methods used in measuring the uranium and plutonium standards so traceability can be established. Special precautions are required to minimize the effects of temperature, radiolysis, and evaporation. Standard reference values are periodically corrected to eliminate systematic errors caused by evaporation or decay products. Measurement control is achieved by requiring analysts to analyze a blind QCS each shift a measurement system is used on plant samples. Computer evaluation determines whether or not a measurement is within the +- 3 sigma control limits. Monthly evaluations of the QCS measurements are made to determine current bias correction factors for accountability measurements and detect significant changes in the bias and precision statistics. The evaluations are also used to plan activities for improving the reliability of the analytical chemistry measurements

  12. Standards on Noise Measurements, Rating Schemes, and Definitions: A Compilation. NBS Special Publication 386, 1976 Edition.

    Science.gov (United States)

    Quindry, Thomas L., Ed.

    This compilation deals with material assembled from the various standards set forth by industrial and trade organizations, or technical and scientific societies concerned with acoustics. There has been no attempt to review or evaluate the standards, but rather just to list documents covering measurement techniques, calibration methods,…

  13. 38 CFR 21.7670 - Measurement of courses leading to a standard, undergraduate college degree.

    Science.gov (United States)

    2010-07-01

    ... leading to a standard, undergraduate college degree. 21.7670 Section 21.7670 Pensions, Bonuses, and... leading to a standard, undergraduate college degree. Except as provided in § 21.7672, VA will measure a...) Other requirements. Notwithstanding any other provision of this section, in administering benefits...

  14. Relationship between grip, pinch strengths and anthropometric variables, types of pitch throwing among Japanese high school baseball pitchers.

    Science.gov (United States)

    Tajika, Tsuyoshi; Kobayashi, Tsutomu; Yamamoto, Atsushi; Shitara, Hitoshi; Ichinose, Tsuyoshi; Shimoyama, Daisuke; Okura, Chisa; Kanazawa, Saeko; Nagai, Ayako; Takagishi, Kenji

    2015-03-01

    Grip and pinch strength are crucially important attributes and standard parameters related to the functional integrity of the hand. It seems significant to investigate normative data for grip and pinch strength of baseball players to evaluate their performance and condition. Nevertheless, few reports have explained the association between grip and pinch strength and anthropometric variables and types of pitch throwing for baseball pitchers. The aim of this study was to measure and evaluate clinical normative data for grip and tip, key, palmar pinch strength and to assess the relationship between these data and anthropometric variables and types of pitch throwing among Japanese high-school baseball pitchers. One hundred-thirty three healthy high school baseball pitchers were examined and had completed a self-administered questionnaire including items related to age, hand dominance, throwing ratio of type of pitch. A digital dynamometer was used to measure grip strength and a pinch gauge to measure tip, key and palmer pinch in both dominant and nondominant side. Body composition was measured by the multi frequency segmental body composition analyzer. Grip strength and tip and palmer pinch strength in dominant side were statistically greater than them in nondominant side (P strength and height (r = 0.33, P strength were predictors of grip strength in dominant side. No statistical significant correlations were found between the throwing ratio of types of pitches thrown and grip strength and tip, key, palmar pinch strength. Our result provides normative values and evidences for grip and pinch strengths in high school baseball pitchers.

  15. Urinary Sex Steroids and Anthropometric Markers of Puberty - A Novel Approach to Characterising Within-Person Changes of Puberty Hormones.

    Science.gov (United States)

    Singh, Gurmeet K S; Balzer, Ben W R; Kelly, Patrick J; Paxton, Karen; Hawke, Catherine I; Handelsman, David J; Steinbeck, Katharine S

    2015-01-01

    The longitudinal relationships of within-individual hormone and anthropometric changes during puberty have not ever been fully described. The objectives of this study were to demonstrate that 3 monthly urine collection was feasible in young adolescents and to utilise liquid chromatography-tandem mass spectrometry assay methods for serum and urine testosterone (T), estradiol (E2) and luteinizing hormone (LH) in adolescents by relating temporal changes in urine and serum hormones over 12 months to standard measures of pubertal development. A community sample of 104 adolescents (57 female) was studied over 12 months with annual anthropometric assessment, blood sampling and self-rated Tanner staging and urine collected every 3 months. Serum and urine sex steroids (T, E2) were measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and LH by immunoassay. A high proportion (92%) of scheduled samples were obtained with low attrition rate of 6.7% over the 12 months. Urine hormone measurements correlated cross-sectionally and longitudinally with age, anthropometry and Tanner stage. We have developed a feasible and valid sampling methodology and measurements for puberty hormones in urine, which allows a sampling frequency by which individual pubertal progression in adolescents can be described in depth.

  16. Urinary Sex Steroids and Anthropometric Markers of Puberty - A Novel Approach to Characterising Within-Person Changes of Puberty Hormones.

    Directory of Open Access Journals (Sweden)

    Gurmeet K S Singh

    Full Text Available The longitudinal relationships of within-individual hormone and anthropometric changes during puberty have not ever been fully described. The objectives of this study were to demonstrate that 3 monthly urine collection was feasible in young adolescents and to utilise liquid chromatography-tandem mass spectrometry assay methods for serum and urine testosterone (T, estradiol (E2 and luteinizing hormone (LH in adolescents by relating temporal changes in urine and serum hormones over 12 months to standard measures of pubertal development.A community sample of 104 adolescents (57 female was studied over 12 months with annual anthropometric assessment, blood sampling and self-rated Tanner staging and urine collected every 3 months. Serum and urine sex steroids (T, E2 were measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS and LH by immunoassay.A high proportion (92% of scheduled samples were obtained with low attrition rate of 6.7% over the 12 months. Urine hormone measurements correlated cross-sectionally and longitudinally with age, anthropometry and Tanner stage.We have developed a feasible and valid sampling methodology and measurements for puberty hormones in urine, which allows a sampling frequency by which individual pubertal progression in adolescents can be described in depth.

  17. Anthropometric and physical fitness characteristics of female ...

    African Journals Online (AJOL)

    These included 24 university-level, 17 provincial-level, and 14 national team players. Anthropometric data included age, stature, body mass, sum of seven skinfolds and percentage body fat. The fitness characteristics included flexibility, strength, explosive power, muscular endurance, agility, speed and aerobic endurance.

  18. Anthropometric and performance characteristics of Turkey National ...

    African Journals Online (AJOL)

    The main objective of this research was to determine the anthropometric, somatotype and performance characteristics of the Turkish National U-14 Female Volleyball Team that participated in the national team selection session. Fifty- eight (58) female volleyball players from various towns in Turkey camped to compete in ...

  19. Sports participation, anthropometric and physiological profiles of ...

    African Journals Online (AJOL)

    Sports participation has been adjudged to enhance healthy living. This study described anthropometric and physiological (A-P) profiles of university athletes based on types of sports (ToS) and duration (in years) of participation (DoP). One hundred and twenty-nine athletes (69 males, 60 females), aged l5-36, who had ...

  20. The association between dyslipidemia and anthropometric ...

    African Journals Online (AJOL)

    Objectives: To determine the association between dyslipidemia and anthropometric indices in black and white adolescents. ... and skinfolds, blood pressure and blood for glucose, insulin, total cholesterol (TC), low density lipoprotein (LDL), high density lipoprotein (HDL), triglycerides (Trig) and C - reactive protein (CRP).

  1. Anthropometric, physical and motor performance determinants of ...

    African Journals Online (AJOL)

    The most talented subjects (N = 39) were selected from 66 boys by means of a Talent Search testing protocol and then subjected to a sport specific test battery consisting of five anthropometric and 16 physical and motor variables. The results indicated that mean anaerobic power output, acceleration, body mass, reaction ...

  2. The influence of biological maturation on anthropometric ...

    African Journals Online (AJOL)

    The aim of this study was to determine whether biological maturation would significantly influence the anthropometric determinants of talent identification among U-14 provincial girl tennis players. Twenty-six of the top thirty-two provincial female players (mean age = 13.21± 0.72 years) from the Northern Gauteng and the ...

  3. Prevalence and factors associated with anthropometric failure ...

    African Journals Online (AJOL)

    Prevalence and factors associated with anthropometric failure, vitamin A and iron deficiency among adolescents in a Nigerian urban community. Rufina NB Ayogu, Ngozi M Nnam, Onyinye Ibemesi, Franca Okechukwu. University of Nigeria, Nsukka. Abstract. Background: Under nutrition is a problem of severe magnitude in ...

  4. The relationship between anthropometric indices and ...

    African Journals Online (AJOL)

    The relationship between anthropometric indices and gastrointestinal helminth infection in primary school children of Batagarawa Local Government Area, Katsina ... poor personal hygiene and lack of knowledge favoured increase in the prevalence of infection, disease prevalence may have an effect the BMI of the children.

  5. Anthropometrical Profile, Skinfold Tickness and Subcutaneous Fat ...

    African Journals Online (AJOL)

    Background: The threatening health problems resulting from excess subcutaneous fat depositions have been reported by the world Health Organization. Also noteworthy is that childhood obesity is a pointer to adult obesity. This necessitated a study on the anthropometrical profiles of adolescents of Southeast Nigeria using ...

  6. The relationship between anthropometric characteristics and ...

    African Journals Online (AJOL)

    This study investigated the relationship between anthropometric characteristics and physical fitness profile of socially disadvantaged South African boys. Three hundred and sixty boys between the aged 7-18 years were randomly selected from schools in an informal settlement in Cape Town to participate in the research.

  7. Relationship between Anthropometric Indices and Dyslipidemia ...

    African Journals Online (AJOL)

    Background: Several studies were undertaken in both developed and developing countries to investigate the relationship between lipid abnormalities and anthropometric indices. In Sudan, however, no data are available, particularly among Sudanese women. Objectives: This study aimed at investigating the relationship ...

  8. Best practices in selecting performance measures and standards for effective asset management.

    Science.gov (United States)

    2011-06-01

    "This report assesses and provides guidance on best practices in performance measurement, management and standards : setting for effective Transportation Asset Management (TAM). The study is conducted through a literature review, a : survey of the 50...

  9. Measuring the activity of BioBrick promoters using an in vivo reference standard

    Directory of Open Access Journals (Sweden)

    Kelly Jason R

    2009-03-01

    Full Text Available Abstract Background The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. Results We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101 to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Conclusion Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement

  10. Anthropometric and body composition characteristics during pregnancy: a study from West Bengal, India.

    Science.gov (United States)

    Ghosh, Arnab

    2012-06-01

    The present cross-sectional study was aimed at investigating changes in anthropometric, body composition and blood pressure characteristics during pregnancy. A total of 406 healthy, pregnant women aged between 16 and 33 years participated in the study. Pregnant women were recruited from the outpatient department of the two-referral hospital in Bolpur subdivision of Birbhum district, West Bengal, India. Anthropometric measures such as height, weight, three circumferences and skinfold thickness at four sites (biceps, triceps, subscapular and suprailaic) were obtained using standard techniques. Percentages of body fat (%BF), intra abdominal visceral fat (IVF), basal metabolic rate (BMR) and body mass index (BMI) were measured using an Omron body fat analyser. Two forenoon blood pressure measurements were also taken and averaged for analysis. Subjects were categorized into three trimester groups: Group I, n=30; Group II, n=163; and Group III, n=213. ANOVA with Scheffe's post-hoc test revealed that Group I had significantly lower mean than both Group II and Group III for systolic blood pressure and IVF, whereas Group I had significantly lower mean than Group III for BMI, BMR, %BF, diastolic blood pressure and skinfolds. The mean change in maternal weight from the first to the third trimester was merely 3 kg. Mean waist circumference varied from the first to the third trimester but not from the first to the second trimester. Furthermore, significantly increased systolic and diastolic blood pressure was observed across the trimesters. However, longitudinal studies involving interaction of body fat topography and pregnancy-induced hormones are required to further our understanding of gestation mechanism. Copyright © 2012 Elsevier GmbH. All rights reserved.

  11. Design Of Measurements For Evaluating Readiness Of Technoware Components To Meet The Required Standard Of Products

    Science.gov (United States)

    Fauzi, Ilham; Muharram Hasby, Fariz; Irianto, Dradjad

    2018-03-01

    Although government is able to make mandatory standards that must be obeyed by the industry, the respective industries themselves often have difficulties to fulfil the requirements described in those standards. This is especially true in many small and medium sized enterprises that lack the required capital to invest in standard-compliant equipment and machineries. This study aims to develop a set of measurement tools for evaluating the level of readiness of production technology with respect to the requirements of a product standard based on the quality function deployment (QFD) method. By combining the QFD methodology, UNESCAP Technometric model [9] and Analytic Hierarchy Process (AHP), this model is used to measure a firm’s capability to fulfill government standard in the toy making industry. Expert opinions from both the governmental officers responsible for setting and implementing standards and the industry practitioners responsible for managing manufacturing processes are collected and processed to find out the technological capabilities that should be improved by the firm to fulfill the existing standard. This study showed that the proposed model can be used successfully to measure the gap between the requirements of the standard and the readiness of technoware technological component in a particular firm.

  12. Development of a Primary Standard for Calibration of [18F]FDG Activity Measurement Systems

    International Nuclear Information System (INIS)

    Capogni, M; Felice, P De; Fazio, A; Simonelli, F; Abbas, K

    2006-01-01

    The 18 F national primary standard was developed by the INMRI-ENEA using the 4πβ Liquid Scintillation Spectrometry Method with 3 H-Standard Efficiency Tracing. Measurements were performed at JRCIspra under a scientific collaboration between the Institute for Health and Consumer Production, the Amersham Health and the National Institute for Occupational Safety and Prevention (ISPESL). The goal of the work was to calibrate, with minimum uncertainty, the INMRI-ENEA transfer standard portable well-type ionisation chamber as well as other JRC-Ispra and Amersham Health reference Ionising Chambers used for FDG activity measurement

  13. Development of a Primary Standard for Calibration of [{sup 18}F]FDG Activity Measurement Systems

    Energy Technology Data Exchange (ETDEWEB)

    Capogni, M [ENEA Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), Centro Ricerche Casaccia, I-00060 Rome (Italy); Felice, P De [ENEA Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), Centro Ricerche Casaccia, I-00060 Rome (Italy); Fazio, A [ENEA Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), Centro Ricerche Casaccia, I-00060 Rome (Italy); Simonelli, F [Institute for Health and Consumer Protection, Joint Research Centre (JRC), European Commission, I-21020 Ispra (Vatican City State, Holy See,), Italy; D' Ursi, V [Amersham Health Srl (AH), I-13040 Saluggia (Saint Vincent and the Grenadines), Italy; Pecorale, A [Amersham Health Srl (AH), I-13040 Saluggia (Saint Vincent and the Grenadines), Italy; Giliberti, C [Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro (ISPESL), I-00184 Rome (Italy); Abbas, K [Institute for Health and Consumer Protection, Joint Research Centre (JRC), European Commission, I-21020 Ispra (Vatican City State, Holy See,), Italy

    2006-05-15

    The {sup 18}F national primary standard was developed by the INMRI-ENEA using the 4{pi}{beta} Liquid Scintillation Spectrometry Method with {sup 3}H-Standard Efficiency Tracing. Measurements were performed at JRCIspra under a scientific collaboration between the Institute for Health and Consumer Production, the Amersham Health and the National Institute for Occupational Safety and Prevention (ISPESL). The goal of the work was to calibrate, with minimum uncertainty, the INMRI-ENEA transfer standard portable well-type ionisation chamber as well as other JRC-Ispra and Amersham Health reference Ionising Chambers used for FDG activity measurement.

  14. Secondary standards (non-activation) for neutron data measurements above 20 MeV

    International Nuclear Information System (INIS)

    Haight, R.C.

    1991-01-01

    In addition to H(n,p) scattering and 235,238 U(n,f) reactions, secondary standards for neutron flux determination may be useful for neutron energies above 20 MeV. For experiments where gamma rays are detected, reference gamma-ray production cross sections are relevant. For neutron-induced charged particle production, standard (n,p) and (n,alpha) cross sections would be helpful. Total cross section standards would serve to check the accuracy of these measurements. These secondary standards are desirable because they can be used with the same detector systems employed in measuring the quantities of interest. Uncertainties due to detector efficiency, geometrical effects, timing and length of flight paths can therefore be significantly reduced. Several secondary standards that do not depend on activation techniques are proposed. 14 refs

  15. Standard test method for measurement of oxidation-reduction potential (ORP) of soil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a procedure and related test equipment for measuring oxidation-reduction potential (ORP) of soil samples removed from the ground. 1.2 The procedure in Section 9 is appropriate for field and laboratory measurements. 1.3 Accurate measurement of oxidation-reduction potential aids in the analysis of soil corrosivity and its impact on buried metallic structure corrosion rates. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Relationship between anthropometric variables and nutrient intake in apparently healthy male elderly individuals: A study from Pakistan

    Directory of Open Access Journals (Sweden)

    Pawelec Graham

    2011-10-01

    Full Text Available Abstract Background The elderly population is increasing worldwide, which warrants their nutritional status assessment more important. The present study was undertaken to establish the nutritional status of the least-studied elderly population in Pakistan. Methods This was a cross-sectional study with a sample of 526 generally healthy free-living elderly men (mean age: 68.9 yr; range: 50-98 yr from Peshawar, Pakistan. Anthropometric measurements (weight, height, WC were measured and BMI and WHR were calculated from these measurements following WHO standard procedures. Dietary intake was assessed by 24-hr dietary recall. Nutrients were calculated from the information on food intake. Nutrients in terms of % of RNI were calculated using WHO data on recommended intakes. Results Based on BMI, the numbers of obese, overweight and underweight elderly were 13.1, 3.1 and 10.8%, respectively. Age was negatively and significantly correlated with BMI (p = 0.0028. Energy (p = 0.0564 and protein intake (p = 0.0776 tended to decrease with age. There was a significant increase in % BF with age (p = p p Conclusions Malnutrition is common in apparently healthy elderly Pakistani men. Very few elderly have adequate nutrient intake. Obese and overweight had higher % BF as compared to normal weight elderly. Older age is associated with changes not only in anthropometrics and body composition but also in intake of key nutrients like energy and protein.

  17. Anthropometric Status and Nutritional Intake in Children (6–9 Years in Valencia (Spain: The ANIVA Study

    Directory of Open Access Journals (Sweden)

    María Morales-Suárez-Varela

    2015-12-01

    Full Text Available The aim of our study was to assess nutritional intake and anthropometric statuses in schoolchildren to subsequently determine nutritional adequacy with Spanish Dietary Reference Intake (DRIs. The ANIVA study, a descriptive cross-sectional study, was conducted in 710 schoolchildren (6–9 years in 2013–2014 in Valencia (Spain. Children’s dietary intake was measured using 3-day food records, completed by parents. Anthropometric measures (weight and height were measured according to international standards, and BMI-for-age was calculated and converted into z-scores by WHO-Anthro for age and sex. Nutrient adequacy was assessed using DRI based on estimated average requirement (EAR or adequate intake (AI. Pearson’s chi-square and Student’s t-test were employed. Of our study group (47.61% boys, 52.39% girls, 53.1% were normoweight and the weight of 46.9% was inadequate; of these, 38.6% had excess body weight (19.6% overweight and 19.0% obesity. We found intakes were lower for biotin, fiber, fluoride, vitamin D (p < 0.016, zinc, iodine, vitamin E, folic acid, calcium and iron (p < 0.017, and higher for lipids, proteins and cholesterol. Our results identify better nutritional adequacy to Spanish recommendations in overweight children. Our findings suggest that nutritional intervention and educational strategies are needed to promote healthy eating in these children and nutritional adequacies.

  18. The relation between the anthropometric characteristics of fingers and cancer

    Directory of Open Access Journals (Sweden)

    Omid Mardanshahi

    2017-07-01

    Full Text Available Anthropometry is a science of human body measurement that could be used for manufacturing artificial limbs or prosthesis, investigating body differences between populations, utilizing in forensics and criminology, or even in the diagnosis of some diseases. Two of the most important anthropometric characteristics are dermatoglyphic patterns and finger length. Many studies have evaluated the relation between these two characteristics in different diseases such as cancers. It assumed that dermatoglyphic patterns and finger length could be used as predictors of some cancers such as gastric, ovarian, prostate, testicular, and breast cancers. In this review, we evaluated the relation between dermatoglyphic variability and finger length in different cancers more precisely.

  19. Anthropometric profile of combat athletes via multivariate analysis.

    Science.gov (United States)

    Burdukiewicz, Anna; Pietraszewska, Jadwiga; Stachoń, Aleksandra; Andrzejewska, Justyna

    2017-11-07

    Athletic success is a complex phenotype influenced by multiple factors, from sport-specific skills to anthropometric characteristics. Considering the latter, the literature has repeatedly indicated that athletes possess distinct physical characteristics depending on the practiced discipline. The aim of the present study was to apply univariate and multivariate methods to assess a wide range of morphometric and somatotypic characteristics in male combat athletes. Biometric data were obtained from 206 male university-level practitioners of judo, jiu-jitsu, karate, kickboxing, taekwondo, and wrestling. Measures included height- and length-based variables, breadths, circumferences, and skinfolds. Body proportions and somatotype, using Sheldon's method of somatotopy as modified by Heath and Carter, were then determined. Body fat percentage was assessed by bioelectrical impedance analysis using tetrapolar hand-to-foot electrodes. Data were subjected to a wide array of statistical analysis. The results show between-group differences in the magnitudes of the analyzed characteristics. While mesomorphy was the dominant component of each group somatotype, enhanced ectomorphy was observed in those disciplines that require a high level of agility. Principal component analysis reduced the multivariate dimensionality of the data to three components (characterizing body size, height-based measures, and the anthropometric structure of the upper extremities) that explained the majority of data variance. The development of a sport-specific anthropometric profile via height- and mass-based and morphometric and somatotypic variables can aid in the design of training protocols and the identification of athlete markers as well as serve as a diagnostic criterion in predicting combat athlete performance.

  20. Anthropometric indicators as screening instrument for falls in the elderly

    Directory of Open Access Journals (Sweden)

    Drielly Soares Freitas

    2016-12-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2016v18n5p530   Anthropometric indicators enable professionals for predicting risk of falls in the elderly; however, there is a gap in literature on reference values. This study analyzes anthropometric indicators such as screening tests for falls in the elderly. Cross-sectional population-based systematic sampling was conducted through a household survey and body composition assessment. Anthropometric measurements were performed using portable electronic scale and stadiometer. Bioimpedance device was used to measure body mass index, body fat and lean body mass. Falls were evaluated in the 12 months preceding the interview as a dependent variable. Discriminatory analysis was performed for falls through the ROC curve, sensitivity, specificity, positive and negative predictive values. Overall, 275 older adults participated in this study, whose prevalence of falls was 23.6%. The average body mass index was 27.8kg/cm2 and 52.1% of individuals were overweight. Among older men, height (ROC=0.68; 95%CI 0.54-0.78 and lean body mass (ROC=0.63, 95%CI 0.58- 0.76 were associated to the occurrence of falls. When considering cutoff of 52.2kg and 166cm, sensitivity was obtained in 75% and high negative predictive values (88.1% and 89.1% respectively. For women, lean body mass (ROC=0.61, 95%CI 0.30-0.49 and body mass (ROC=0.60, 95%CI 0.53-0.72 were relevant from the optimal cutoff point of 28.9% and 57.2kg/m2. Lean body mass was more sensitive (63.2% and body mass little more specific (64.3%, both with high negative predictive values (82.0% and 83.0%. The indicators used were able to discriminate older adults who have suffered from falls.

  1. Precision and accuracy, two steps towards the standardization of XRPD measurements

    Energy Technology Data Exchange (ETDEWEB)

    Berti, G. [Pisa Univ. (Italy). Dept. of Earth Sciences

    1996-09-01

    Any standardization process requires to get at results comprehensible, reproducible and traceable. Precision and accuracy of the measurements play a key role in getting at these requirements. The adoption of either physical (standard) or mathematical models allows for describing the whole diffraction measurement process with the necessary physical significance. From an other hand, the adoption of procedure, which are capable of controlling the measurement process, renders it reproducible and traceable. The falling of those requirements make difficult to transfer or replicate elsewhere experiences which may give even excellent result in a given laboratory.

  2. Micronutrients Fe, Zn and Ca and their relationship with anthropometric indices and dental health among children

    Directory of Open Access Journals (Sweden)

    Pourhashemi S.J.

    2008-06-01

    Full Text Available Background: Proper nutrition has an important role in the physical and psychological development of children. The aim of this survey is to compare the nutrition of a community to the recommended daily amount (RDA to determine deficiencies and present recommendations for improvement.Methods: In this cross-sectional study conducted in Tehran, Iran, 788 children, all seven years of age, were selected via cluster sampling and evaluated using standard questionnaires with a 24-hr recall regarding the frequency and type of food intake. Then by measurement of weight and height, their anthropometric and DMFT (decayed/missing/filled teeth indices were determined using the Kruskal-Wallis one-way analysis of variance, and Mann-Whitney U and chi-square tests.Results: Relative to the RDA, 23.6% of children had low intake of Ca, and 3.2% and 5.2% were deficient for Fe and Zn, respectively. Anthropometric measurements showed that 15.7% were malnourished based on weight for age, 10.5% based on height for age and 16.8% based on weight for height indices. The DMFT indices for children with dietary Ca levels under 75% of the RDA were significantly higher than those with sufficient Ca intake (P<0.001. The mean DMFT indices for dental development were 0.22 for permanent teeth (four molars; SD=0.64 and 4.64 for primary teeth (SD=3.24. We found a significant correlation between DMFT indices and low Fe intake: the DMFT indices of children with iron deficiency were much higher than those with sufficient iron intake.Conclusions: Children in Tehran do not receive enough Ca Fe and Zn from their diets. This problem causes mild malnutrition and increases the risk of dental caries.

  3. Influence of anthropometric profile on physical performance in elite female volleyballers in relation to playing position.

    Science.gov (United States)

    Mielgo-Ayuso, Juan; Calleja-González, Julio; Clemente-Suárez, Vicente J; Zourdos, Michael C

    2014-10-06

    The anthropometric profile, specifically body composition, plays a crucial role in the physical performance of volleyballers. Since there are varying positions in volleyball, it is likely that differences exist in anthropometric and physical performance profiles among players due each role's specific physical requirements. The aims of this study were to analyze the anthropometric and physical performance profiles of elite female volleyballers, to determine any differences in these features among different playing positions. A further aim was to examine any relationship between anthropometric measures and measures of performance. This study assessed 42 female professional volleyball players (Age: 27.2±5.4 years). Players were categorized according to playing position: middle blockers (n=12), opposite hitters (n=6), outside hitters (n=12), setters (n=8), and liberos (n=4). Anthropometric measurements assessed were: height, weight, fat mass (5 skinfolds) musculoskeletal mass (5 corrected girths). Additionally, the physical performance parameters examined were: jump tests (vertical-jump and spike-jump), speed, agility, and strength tests (crunches test and overhead medicine ball throw). In terms of height middle blockers were the tallest (186.5±1.4 cm), while liberos were the shortest (166.7±8.1 cm). There were significant differences in body mass among positions (p. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  4. Validity of anthropometric equations to estimate infant fat mass at birth and in early infancy.

    Science.gov (United States)

    Cauble, Jennifer S; Dewi, Mira; Hull, Holly R

    2017-03-27

    In newborns and children, body fat estimation equations are often used at different ages than the age used to develop the equations. Limited validation studies exist for newborn body fat estimation equations at birth or later in infancy. The study purpose was to validate 4 newborn fat mass (FM) estimation equations in comparison to FM measured by air displacement plethysmography (ADP; the Pea Pod) at birth and 3 months. Ninety-five newborns (1-3 days) had their body composition measured by ADP and anthropometrics assessed by skinfolds. Sixty-three infants had repeat measures taken (3 months). FM measured by ADP was compared to FM from the skinfold estimation equations (Deierlein, Catalano, Lingwood, and Aris). Paired t-tests assessed mean differences, linear regression assessed accuracy, precision was assessed by R 2 and standard error of the estimate (SEE), and bias was assessed by Bland-Altman plots. At birth, FM measured by ADP differed from FM estimated by Deierlein, Lingwood and Aris equations, but did not differ from the Catalano equation. At 3 months, FM measured by ADP was different from all equations. At both time points, poor precision and accuracy was detected. Bias was detected in most all equations. Poor agreement, precision, and accuracy were found between prediction equations and the criterion at birth and 3 months.

  5. [Blood pressure measurement by primary care physicians: comparison with the standard method].

    Science.gov (United States)

    Asai, Y; Kawamoto, R; Nago, N; Kajii, E

    2000-04-01

    To examine the usual methods of blood pressure (BP) measurement by primary care physicians and to compare them with the standard methods. Cross-sectional survey by self-administered questionnaire. Primary care physicians who graduated from Jichi Medical School and were working at clinics. Each standard method for 20 items was defined as the one that was most frequently recommended by 6 guidelines (USA 3, UK 1, Canada 1, Japan 1) and a recent comprehensive review about BP measurement. Of 333 physicians, 190 (58%) responded (median age 33, range 26 to 45 years). Standard methods and percentages of physicians who follow them are: [BP measurement, 17 items] supported arm 96%; measurement to 2 mmHg 91%; sitting position 86%; mercury sphygmomanometer 83%; waiting > or = 1 minute between readings 58%; palpation to assess systolic BP before auscultation 57%; check accuracy of home BP monitor 56%; Korotkoff Phase V for diastolic BP 51%; bilateral measurements on initial visit 44%; small cuff available 41%; > or = 2 readings in patients with atrial fibrillation 38%; > or = 2 readings on one visit 20%; cuff deflation rate of 2 mmHg/pulse 14%; large cuff available 13%; check accuracy of monitor used for home visit 8%; waiting time > or = 5 minute 3%; readings from the arm with the higher BP 1%. [Knowledge about BP monitor, 2 items] appropriate size bladder: length 11%; width 11%. [Check of sphygmomanometer for leakage, inflate to 200 mmHg then close valve for 1 minute] leakage < 2 mmHg 6%; median 10 (range 0-200) mmHg. Average percentage of all 20 items was 39%. Number of methods physicians follow as standard: median 8 (range 4 to 15) and this number did not correlate with any background characteristics of the physicians. Furthermore, we also obtained information on methods not compared with the standard. Fifty-four percentage of physicians used more standard methods in deciding the start or change of treatment than in measuring BP of patients with good control. About 80% of

  6. Nanomechanical motion measured with an imprecision below that at the standard quantum limit.

    Science.gov (United States)

    Teufel, J D; Donner, T; Castellanos-Beltran, M A; Harlow, J W; Lehnert, K W

    2009-12-01

    Nanomechanical oscillators are at the heart of ultrasensitive detectors of force, mass and motion. As these detectors progress to even better sensitivity, they will encounter measurement limits imposed by the laws of quantum mechanics. If the imprecision of a measurement of the displacement of an oscillator is pushed below a scale set by the standard quantum limit, the measurement must perturb the motion of the oscillator by an amount larger than that scale. Here we show a displacement measurement with an imprecision below the standard quantum limit scale. We achieve this imprecision by measuring the motion of a nanomechanical oscillator with a nearly shot-noise limited microwave interferometer. As the interferometer is naturally operated at cryogenic temperatures, the thermal motion of the oscillator is minimized, yielding an excellent force detector with a sensitivity of 0.51 aN Hz(-1/2). This measurement is a critical step towards observing quantum behaviour in a mechanical object.

  7. Advisory Committee for the Calibration Standards of Ionizing Radiation Measurement. Section 2. Radionucleide Measurement

    International Nuclear Information System (INIS)

    1982-01-01

    Section II (Mesure des radionucleides) of the Comite Consultatif pour les Etalons de Mesure des Rayonnements Ionisants held its sixth meeting in May 1981. The results of an international comparison of 55 Fe, organized by the National Physical Laboratory, and of a trial comparison of 133 Ba were discussed. A full-scale comparison of 137 Cs activity measurements and a repetition of the 133 Ba trial comparison are to take place within the next two years. A trial comparison of 109 Cd is also proposed. Recent work in radioactivity carried out at BIPM was reported. The usefulness of the international reference system for measuring the activity of gamma-ray emitters was generally acknowledged. The new ''selective sampling'' method which avoids measuring coincidences attracted much attention. The Working Party reports and a new monograph (BIPM-3) were presented. Finally, there was a broad exchange of information on work in progress at the various laboratories represented at the meeting [fr

  8. Standard test method for measurement of web/roller friction characteristics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers the simulation of a roller/web transport tribosystem and the measurement of the static and kinetic coefficient of friction of the web/roller couple when sliding occurs between the two. The objective of this test method is to provide users with web/roller friction information that can be used for process control, design calculations, and for any other function where web/roller friction needs to be known. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard test method for measurement of corrosion potentials of Aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a procedure for measurement of the corrosion potential (see Note 1) of an aluminum alloy in an aqueous solution of sodium chloride with enough hydrogen peroxide added to provide an ample supply of cathodic reactant. Note 1—The corrosion potential is sometimes referred to as the open-circuit solution or rest potential. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the measurement of heat transfer rate using a thermal capacitance-type calorimeter which assumes one-dimensional heat conduction into a cylindrical piece of material (slug) with known physical properties. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—For information see Test Methods E 285, E 422, E 458, E 459, and E 511.

  11. Anthropometric evaluation and recommendation for primary schools classroom furniture design in Perlis

    Science.gov (United States)

    Shan, Lim Shaiu; Jing, Ewe Hui; Effendi, M. S. M.; Rosli, Muhamad Farizuan

    2017-09-01

    This study was carried out with the objective to obtain the anthropometric data of primary school children from Year 1 to Year 6 and evaluate the children's anthropometry with the current dimensions of classroom furniture (i.e. chair and table). In addition, this study also proposed the design dimensions for the improvement in classroom furniture design with the consideration of children's anthropometric data. A total of 390 children selected from 13 primary schools in Perlis, Malaysia were participated in this study. There were 11 anthropometric measurements of children have been measured in this study, which include stature (St), popliteal height (PH), knee height (KH), thigh thickness (TT), buttock popliteal length (BPL), hip breadth (HB), sitting shoulder height (SSH), sitting elbow height (SEH), forearm-hand length (FHL), height of lumbar point (HLP) and buttock clearance (BC). Besides that, 7 dimensions relating to current classroom chair have been measured, such as seat height (SH), seat depth (SD), seat width (SW), upper edge of backrest (UEB), lower edge of backrest (LEB), S point (SP), overall chair height (OCH). Another 5 dimensions of the existing classroom table have been measured too, which involve table height (TH), table depth (TD), table width (TW), under table height (UH) and seat to table clearance (STC). All the measurements were performed by using metal measuring tape. The anthropometric data of the children were analyzed with the help of Microsoft Excel 2013. Several equations with associated with the anthropometric data and furniture dimensions have been applied in this research. The new design dimensions for classroom furniture that proposed in this paper which based on the collected anthropometric data can be referred as a guideline for classroom furniture design. The implementation of these data may help to create comfortability, safety, suitability and improve performance of children in the classroom.

  12. ANTHROPOMETRIC STUDY OF NASAL INDEX OF EGYPTIANS

    OpenAIRE

    Abdelmonem Awad Hegazy

    2014-01-01

    Background: The nasal index determination is one of the most commonly used anthropometric parameters in classifying human races. There are few reports in medical literature concerning nasal index that specifically address particular Egyptian populations. The objective of this study was to determine the normal parameters of external nose (width, height and nasal index) in Egyptians. Methods: The study was conducted randomly on healthy Egyptian subjects of both sexes. Nasal height and width ...

  13. GDP per capita and the biological standard of living in contemporary developing countries

    NARCIS (Netherlands)

    Brinkman, Henk-Jan; Drukker, J.W.; Slot, Brigitte

    1997-01-01

    This paper investigates whether a divergence between the biological standard of living (commonly measured by some anthropometric indicator) and GDP per capita during the early phases of industrialization, as observed for many now-developed countries in the nineteenth century, can also be found for

  14. The primary exposure standard for Co-60 gamma radiation: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a cavity ionization chamber used, as a primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the ENEA in Italy. The primary standard is designed to make absolute measurements of exposure due to the Co-60 gamma radiation. The procedures for the realizationof the exposure unit are also described. Finally results of some international comparisons are reported

  15. Protocol of the COSMIN study: COnsensus-based Standards for the selection of health Measurement INstruments

    Directory of Open Access Journals (Sweden)

    Patrick DL

    2006-01-01

    Full Text Available Abstract Background Choosing an adequate measurement instrument depends on the proposed use of the instrument, the concept to be measured, the measurement properties (e.g. internal consistency, reproducibility, content and construct validity, responsiveness, and interpretability, the requirements, the burden for subjects, and costs of the available instruments. As far as measurement properties are concerned, there are no sufficiently specific standards for the evaluation of measurement properties of instruments to measure health status, and also no explicit criteria for what constitutes good measurement properties. In this paper we describe the protocol for the COSMIN study, the objective of which is to develop a checklist that contains COnsensus-based Standards for the selection of health Measurement INstruments, including explicit criteria for satisfying these standards. We will focus on evaluative health related patient-reported outcomes (HR-PROs, i.e. patient-reported health measurement instruments used in a longitudinal design as an outcome measure, excluding health care related PROs, such as satisfaction with care or adherence. The COSMIN standards will be made available in the form of an easily applicable checklist. Method An international Delphi study will be performed to reach consensus on which and how measurement properties should be assessed, and on criteria for good measurement properties. Two sources of input will be used for the Delphi study: (1 a systematic review of properties, standards and criteria of measurement properties found in systematic reviews of measurement instruments, and (2 an additional literature search of methodological articles presenting a comprehensive checklist of standards and criteria. The Delphi study will consist of four (written Delphi rounds, with approximately 30 expert panel members with different backgrounds in clinical medicine, biostatistics, psychology, and epidemiology. The final checklist will

  16. Standardization and quality assurance in fluorescence measurements I state-of-the art and future challenges

    CERN Document Server

    Resch-Genger, Ute

    2008-01-01

    The validation and standardization of fluorescence methods is still in its infancy as compared to other prominent analytical and bioanalytical methods. Appropriate quality assurance standards are however a prerequisite for applications in highly regulated fields such as medical diagnostics, drug development, or food analysis. For the first time, a team of recognized international experts has documented the present status of quality assurance in fluorescence measurements, and outlines concepts for establishing standards in this field. This first of two volumes covers basic aspects and various techniques such as steady-state and time-resolved fluorometry, polarization techniques, and fluorescent chemical sensors

  17. A standardization of the physical tests for external irradiation measuring detectors

    International Nuclear Information System (INIS)

    1977-05-01

    This report is the result of a standardization work, realized within the Radioprotection Services of the A.E.C., of the physical tests for dectors measuring external irradiations. Among the various tests mentionned, calibration and the establishment of the relative spectral response are treated in details. As far as calibration is concerned, the standardization refers to: the reference detector, the reference radiation source, the installation and calibration procedure. As for the relative spectral response the standardization refers to: the reference detector, the radiation sources to be used. High flux detectors and those for pulse electromagnetic radiations are also dealt with [fr

  18. INTERNATIONAL STANDARDS ON FOOD AND ENVIRONMENTAL RADIOACTIVITY MEASUREMENT FOR RADIOLOGICAL PROTECTION: STATUS AND PERSPECTIVES.

    Science.gov (United States)

    Calmet, D; Ameon, R; Bombard, A; Brun, S; Byrde, F; Chen, J; Duda, J-M; Forte, M; Fournier, M; Fronka, A; Haug, T; Herranz, M; Husain, A; Jerome, S; Jiranek, M; Judge, S; Kim, S B; Kwakman, P; Loyen, J; LLaurado, M; Michel, R; Porterfield, D; Ratsirahonana, A; Richards, A; Rovenska, K; Sanada, T; Schuler, C; Thomas, L; Tokonami, S; Tsapalov, A; Yamada, T

    2017-04-01

    Radiological protection is a matter of concern for members of the public and thus national authorities are more likely to trust the quality of radioactivity data provided by accredited laboratories using common standards. Normative approach based on international standards aims to ensure the accuracy or validity of the test result through calibrations and measurements traceable to the International System of Units. This approach guarantees that radioactivity test results on the same types of samples are comparable over time and space as well as between different testing laboratories. Today, testing laboratories involved in radioactivity measurement have a set of more than 150 international standards to help them perform their work. Most of them are published by the International Standardization Organization (ISO) and the International Electrotechnical Commission (IEC). This paper reviews the most essential ISO standards that give guidance to testing laboratories at different stages from sampling planning to the transmission of the test report to their customers, summarizes recent activities and achievements and present the perspectives on new standards under development by the ISO Working Groups dealing with radioactivity measurement in connection with radiological protection. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Anthropometric and growth characteristics of schoolchildren in Novi Sad

    Directory of Open Access Journals (Sweden)

    Bjelanović Jelena

    2017-01-01

    Full Text Available Introduction/Objective. Growth, development and maturation are periods marked with individual physical characteristics, which provide the insight into the health status together with anthropometric indicators and physical appearance of an individual. The aim was to determine body height and body weight of a representative sample of schoolchildren from Novi Sad, to make a comparative analysis in relation to age and gender, and to determine the beginning of accelerated growth. Methods. Sample included 11,676 pupils aged 6–15 years, from Novi Sad, Serbia. The basic anthropometric measurements (body height and body weight were performed according to recommended methodology. Results. The average values of boys’ body height ranged from 125.39 cm in those aged up to six years, to 175.09 cm for boys aged 15, and in girls from 124.07 cm at the age of six, to 165.77 cm for the oldest examined girls. The average values of boys’ body weight ranged from 25.58 kg at the age of six to 61.38 kg at the age of 15, and in girls from 23.94 kg in youngest to 54.46 kg, at the age of 15. The analysis of body weight and body height relation in the sample of boys and girls showed significant differences in all age groups, being most significant in boys aged from 11 to 13 years and in girls aged from nine to 12 years, marking the beginning of the rapid growth period. Conclusion. Having analyzed two basic anthropometric characteristics, i.e. body height and body weight, the authors found significant differences in the increase of these characteristics among the age groups of the study sample. In addition, the results of this research are in accordance with those reported in literature, which suggest that a sudden ponderal and statural growth starts earlier in girls than in boys.

  20. Anthropometric profiles of children with congenital heart disease

    Directory of Open Access Journals (Sweden)

    Damayanti R. Sjarif

    2011-02-01

    Full Text Available Background: Undernutrition is a common cause of morbidity in children with CHD. Previous data from developing country showed prevalence of preoperative undernutrition in children with CHD was up to 45%. The aim of this study are to determine the anthropometric profiles and prevalence of undernutrition in children with CHD by using the anthropometric measurement.Methods: A cross-sectional study was carried out in children aged 0-2 years old with CHD in Cipto Mangunkusumo hospital. All patients underwent an anthropometric evaluation (weight, length and head circumference at presentation. Undernutrition, failure to thrive /FTT, short stature and microcephaly were determined according to WHO, weight-for-length, weight-for-age at 2 points, length-for-age, head circumference-for-age z-score < -2SD accordingly.Results: We had total of 95 patients, 73 patients with acyanotic and 22 patients with cyanotic lesions. Prevalence of undernutrition in CHD was 51.1%, with 22.3% severe undernutrition. FTT was found in 64.9%, short stature in 49.5% and microcephaly in  37% patients. FTT was found higher in acyanotic (72.2% compared to cyanotic lesions (42.9%. In acyanotic, weight was affected more than length (72.2% vs 49.3%. In cyanotic, weight and length affected equally (42.9% vs 54.5%. Diet counseling were done in patients with undernutrition. Medicines, transcatheter or surgery intervention were indicated in selected patients.Conclusions: Prevalence of FTT was higher than undernutrition in children with CHD. FTT was found higher in acyanotic lesions. In acyanotic, weight was affected more than length. In cyanotic, weight and length affected equally. (Med J Indones 2011; 20:40-5Keywords: congenital heart disease, failure to thrive, short stature, undernutrition

  1. Standardized Approach to Quantitatively Measure Residual Limb Skin Health in Individuals with Lower Limb Amputation

    Science.gov (United States)

    Rink, Cameron L.; Wernke, Matthew M.; Powell, Heather M.; Tornero, Mark; Gnyawali, Surya C.; Schroeder, Ryan M.; Kim, Jayne Y.; Denune, Jeffrey A.; Albury, Alexander W.; Gordillo, Gayle M.; Colvin, James M.; Sen, Chandan K.

    2017-01-01

    Objective: (1) Develop a standardized approach to quantitatively measure residual limb skin health. (2) Report reference residual limb skin health values in people with transtibial and transfemoral amputation. Approach: Residual limb health outcomes in individuals with transtibial (n = 5) and transfemoral (n = 5) amputation were compared to able-limb controls (n = 4) using noninvasive imaging (hyperspectral imaging and laser speckle flowmetry) and probe-based approaches (laser doppler flowmetry, transcutaneous oxygen, transepidermal water loss, surface electrical capacitance). Results: A standardized methodology that employs noninvasive imaging and probe-based approaches to measure residual limb skin health are described. Compared to able-limb controls, individuals with transtibial and transfemoral amputation have significantly lower transcutaneous oxygen tension, higher transepidermal water loss, and higher surface electrical capacitance in the residual limb. Innovation: Residual limb health as a critical component of prosthesis rehabilitation for individuals with lower limb amputation is understudied in part due to a lack of clinical measures. Here, we present a standardized approach to measure residual limb health in people with transtibial and transfemoral amputation. Conclusion: Technology advances in noninvasive imaging and probe-based measures are leveraged to develop a standardized approach to quantitatively measure residual limb health in individuals with lower limb loss. Compared to able-limb controls, resting residual limb physiology in people that have had transfemoral or transtibial amputation is characterized by lower transcutaneous oxygen tension and poorer skin barrier function. PMID:28736682

  2. Standardized Approach to Quantitatively Measure Residual Limb Skin Health in Individuals with Lower Limb Amputation.

    Science.gov (United States)

    Rink, Cameron L; Wernke, Matthew M; Powell, Heather M; Tornero, Mark; Gnyawali, Surya C; Schroeder, Ryan M; Kim, Jayne Y; Denune, Jeffrey A; Albury, Alexander W; Gordillo, Gayle M; Colvin, James M; Sen, Chandan K

    2017-07-01

    Objective: (1) Develop a standardized approach to quantitatively measure residual limb skin health. (2) Report reference residual limb skin health values in people with transtibial and transfemoral amputation. Approach: Residual limb health outcomes in individuals with transtibial ( n  = 5) and transfemoral ( n  = 5) amputation were compared to able-limb controls ( n  = 4) using noninvasive imaging (hyperspectral imaging and laser speckle flowmetry) and probe-based approaches (laser doppler flowmetry, transcutaneous oxygen, transepidermal water loss, surface electrical capacitance). Results: A standardized methodology that employs noninvasive imaging and probe-based approaches to measure residual limb skin health are described. Compared to able-limb controls, individuals with transtibial and transfemoral amputation have significantly lower transcutaneous oxygen tension, higher transepidermal water loss, and higher surface electrical capacitance in the residual limb. Innovation: Residual limb health as a critical component of prosthesis rehabilitation for individuals with lower limb amputation is understudied in part due to a lack of clinical measures. Here, we present a standardized approach to measure residual limb health in people with transtibial and transfemoral amputation. Conclusion: Technology advances in noninvasive imaging and probe-based measures are leveraged to develop a standardized approach to quantitatively measure residual limb health in individuals with lower limb loss. Compared to able-limb controls, resting residual limb physiology in people that have had transfemoral or transtibial amputation is characterized by lower transcutaneous oxygen tension and poorer skin barrier function.

  3. Subtraction of subcutaneous fat to improve the prediction of visceral adiposity: exploring a new anthropometric track in overweight and obese youth.

    Science.gov (United States)

    Samouda, H; De Beaufort, C; Stranges, S; Van Nieuwenhuyse, J-P; Dooms, G; Keunen, O; Leite, S; Vaillant, M; Lair, M-L; Dadoun, F

    2017-08-01

    The efficiency of traditional anthropometric measurements such as body mass index (BMI) or waist circumference (Waist C) used to replace biomedical imaging for assessing visceral adipose tissue (VAT) is still highly controversial in youth. We evaluated the most accurate model predicting VAT in overweight/obese youth, using various anthropometric measurements and their correlation with different body fat compartments, especially by testing, for the first time in youth, the hypothesis that subtracting the anthropometric measurement the most highly correlated with subcutaneous abdominal adipose tissue (SAAT) and less correlated possible with VAT from an anthropometric abdominal measurement highly correlated with visceral and total abdominal adipose tissue (TAAT), predicts VAT with higher accuracy. VAT and SAAT data resulted from magnetic resonance imaging (MRI) analysis performed on 181 boys and girls (7-17 y) from Diabetes & Endocrinology Care Paediatrics Clinic in Luxembourg. Height, weight, abdominal diameters, waist, hip, and thigh circumferences were measured with a view to developing the anthropometric VAT predictive algorithms. In girls, subtracting proximal thigh circumference (Proximal Thigh C), the most closely correlated anthropometric measurement with SAAT, from Waist C, the most closely correlated anthropometric measurement with VAT was instrumental in improving VAT prediction, in comparison with the most accurate single VAT anthropometric surrogate. [Formula: see text] Residual analysis showed a negligible estimation error (5 cm 2 ). In boys, Waist C was the best VAT predictor. Subtraction of abdominal subcutaneous fat is important to predict VAT in overweight/obese girls. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Acoustics. Measurement of sound insulation in buildings and of building elements. Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor

    CERN Document Server

    British Standards Institution. London

    1998-01-01

    Acoustics. Measurement of sound insulation in buildings and of building elements. Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor

  5. Standard practice for calculation of corrosion rates and related information from electrochemical measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This practice covers the providing of guidance in converting the results of electrochemical measurements to rates of uniform corrosion. Calculation methods for converting corrosion current density values to either mass loss rates or average penetration rates are given for most engineering alloys. In addition, some guidelines for converting polarization resistance values to corrosion rates are provided. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  6. [Measurement of the knee range of motion: standard goniometer or smartphone?].

    Science.gov (United States)

    Rwakabayiza, Sylvia; Pereira, Luis Carlos; Lécureux, Estelle; Jolles-Haeberli, Brigitte

    2013-12-18

    Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

  7. The relationship between biomechanical-anthropometrical parameters and the force exerted on the head when heading free kicks in soccer.

    Science.gov (United States)

    Teymouri, Meghdad; Sadeghi, Heydar; Nabaei, Amir; Kasaeian, Amir

    2012-01-01

    Soccer is a contact sport in which the players are frequently faced with the risk of injury. It has been shown that the force exerted on the head during heading can be as much as 500-1200 Newton (N). The main objective of this study was to determine whether there was any relationship between the force exerted on the head and several biomechanical and anthropometrical parameters related to heading free kicks. A total of 16 semi-professional soccer players with at least 5 years experience participated in this study. The mean age, height, and weight of the study participants were 21.36 ± 5.67, 178 ± 5.99 cm, and 70.55 ± 8.55 kg, respectively. To measure the force exerted on the heads of the players, a pressure gauge was installed on their foreheads. Each participant was asked to defend the ball using the heading technique three times. A camera with a sampling frequency of 150 frames per second was used to record the moment of impact between the ball and head during each heading event. For each participant and replicate, the ball and head velocity (m/s) as well as the angular body changes (degrees) were calculated using MATLAB and AutoCAD softwares, respectively. Descriptive statistics, including means and standard deviations were used to describe the data. Pearson correlation coefficient (alpha = 0.05) was used to examine potential relationships between the variables of interest. Significant correlations existed between the force exerted on the head during heading, participant age, body mass, body fat percentage, and head perimeter (P < 0.05). The study revealed the significance of anthropometric variables related to heading, such as age and head perimeter. Therefore, it was concluded that these variables should be considered when teaching and practicing the heading technique with players of different ages and anthropometric sizes.

  8. Relationship of age at menarche on anthropometric index and menstrual irregularity in late adolescent girls in Seoul

    Directory of Open Access Journals (Sweden)

    Seung Eun Lee

    2013-09-01

    Full Text Available PurposeTo examine the relationship between menarcheal age and anthropometric indices and menstrual irregularity in late adolescent girls in Seoul.MethodsWe surveyed 4,218 fertile adolescent girls between the ages of 16 and 18 years to determine their anthropometric indices and menarcheal age. Measurements were taken from June 2008 to October 2009 at seven girl's high schools in Seoul, Korea. Participants were offered self-report questionnaire as a survey tool that included questions on anthropometric indices (height, weight, waist circumference, menarcheal age, menstrual pattern, frequency of menstruation per year.ResultsThe participants were categorized into three groups based on menarcheal age: early menarche group (younger than 2 standard deviations [SD], mid menarche group (within ±2 SD, late menarche group (older than 2 SD. The mean age of early menarche group was 9.9±0.2 years, mid menarche group 12.5±0.9 years, late menarche group 15.1±0.3 years (P < 0.001. Heights were recorded as 160.4±5.2 cm, 161.8±4.9 cm, 162.3±4.7 cm in early, mid, and late menarche group, respectively (P = 0.001. Body mass index (BMI and waist circumference significantly were lager in early menarche group than mid and late menarche ones (P < 0.001. The menarcheal age had a positive correlation with height and negative correlations with weight, BMI, waist circumference (P < 0.001. The prevalence of oligomenorrhea was more frequent in late menarche group than early and mid menarche group.ConclusionThe menarcheal age have positive relationship with height and inverse relationship with BMI and waist circumference in late adolescent girls in Seoul. Late menarcheal girls are disposed to have menstrual irregularity compared to early menarcheal girls.

  9. Association of thyroid gland volume, serum insulin-like growth factor-I, and anthropometric variables in euthyroid prepubertal children

    DEFF Research Database (Denmark)

    Boas, M.; Hegedus, L.; Feldt-Rasmussen, U.

    2009-01-01

    CONTEXT AND OBJECTIVE: Few studies have focused on the interrelation between thyroid size, anthropometric variables, and IGF-I in adults, but such data are lacking for children. We have investigated thyroid gland volume and several hormonal and anthropometric variables in prepubertal children....... DESIGN AND PARTICIPANTS: A total of 859 prepubertal euthyroid Danish children aged 4-9 yr underwent a thorough clinical investigation, including anthropometrical measurements and determination of TSH, thyroid hormones, autoantibodies, urinary iodine excretion, and thyroid volume (TV) by ultrasound....... Longitudinal growth data from birth were available. RESULTS: TV increased significantly with age (r = 0.487; P

  10. Comparing biomarker measurements to a normal range: when to use standard error of the mean (SEM) or standard deviation (SD) confidence intervals tests.

    Science.gov (United States)

    Pleil, Joachim D

    2016-01-01

    This commentary is the second of a series outlining one specific concept in interpreting biomarkers data. In the first, an observational method was presented for assessing the distribution of measurements before making parametric calculations. Here, the discussion revolves around the next step, the choice of using standard error of the mean or the calculated standard deviation to compare or predict measurement results.

  11. Physical fitness and anthropometric normative values among Colombian-Indian schoolchildren

    Directory of Open Access Journals (Sweden)

    Jeison Alexander Ramos-Sepúlveda

    2016-09-01

    Full Text Available Abstract Background Substantial evidence indicates that children’s physical fitness levels are markers of their lifestyles and their cardio-metabolic health profile and are predictors of the future risk of chronic diseases such as obesity, cardiometabolic disease, skeletal health and mental health. However, fitness reference values for ethnic children and adolescents have not been published in a Latin-American population. Therefore, the aim of the study was to provide sex- and age-specific physical fitness and anthropometric reference standards among Colombian-Indian schoolchildren. Methods A sample of 576 participants (319 boys and 257 girls aged 10 to 17 years old was assessed using the FUPRECOL test battery. Four components of physical fitness were measured: 1 morphological component: height, weight, body mass index (BMI, waist circumference (WC, triceps skinfold, subscapular skinfold, and body fat (%; 2 musculoskeletal component: handgrip and standing long jump test; 3 motor component: speed/agility test (4 × 10 m shuttle run; and 4 cardiorespiratory component: course-navette 20 m, shuttle run test and estimation of maximal oxygen consumption by VO2max indirect. Centile smoothed curves for the 3rd, 10th, 25th, 50th, 75th, 90th and 97th percentiles were calculated using Cole’s LMS method. Results Our results show that weight, height and BMI in each age group were higher in boys than in girls. In each groups, age showed a significant effect for BMI and WC. Boys showed better than girls in cardiorespiratory fitness, lower- and upper-limb strength and speed/agility and girls performed better in low back flexibility. Conclusion Our results provide for the first time sex- and age-specific physical fitness and anthropometric reference values for Colombian Nasa Indian children and adolescents aged 10–17.9 years.

  12. Evaluation of measurement reproducibility using the standard-sites data, 1994 Fernald field characterization demonstration project

    International Nuclear Information System (INIS)

    Rautman, C.A.

    1996-02-01

    The US Department of Energy conducted the 1994 Fernald (Ohio) field characterization demonstration project to evaluate the performance of a group of both industry-standard and proposed alternative technologies in describing the nature and extent of uranium contamination in surficial soils. Detector stability and measurement reproducibility under actual operating conditions encountered in the field is critical to establishing the credibility of the proposed alternative characterization methods. Comparability of measured uranium activities to those reported by conventional, US Environmental Protection Agency (EPA)-certified laboratory methods is also required. The eleven (11) technologies demonstrated included (1) EPA-standard soil sampling and laboratory mass-spectroscopy analyses, and currently-accepted field-screening techniques using (2) sodium-iodide scintillometers, (3) FIDLER low-energy scintillometers, and (4) a field-portable x-ray fluorescence spectrometer. Proposed advanced characterization techniques included (5) alpha-track detectors, (6) a high-energy beta scintillometer, (7) electret ionization chambers, (8) and (9) a high-resolution gamma-ray spectrometer in two different configurations, (10) a field-adapted laser ablation-inductively coupled plasma-atomic emission spectroscopy (ICP-AES) technique, and (11) a long-range alpha detector. Measurement reproducibility and the accuracy of each method were tested by acquiring numerous replicate measurements of total uranium activity at each of two ''standard sites'' located within the main field demonstration area. Meteorological variables including temperature, relative humidity. and 24-hour rainfall quantities were also recorded in conjunction with the standard-sites measurements

  13. Pitfalls in the measurement of muscle mass: a need for a reference standard

    Science.gov (United States)

    Landi, Francesco; Cesari, Matteo; Fielding, Roger A.; Visser, Marjolein; Engelke, Klaus; Maggi, Stefania; Dennison, Elaine; Al‐Daghri, Nasser M.; Allepaerts, Sophie; Bauer, Jurgen; Bautmans, Ivan; Brandi, Maria Luisa; Bruyère, Olivier; Cederholm, Tommy; Cerreta, Francesca; Cherubini, Antonio; Cooper, Cyrus; Cruz‐Jentoft, Alphonso; McCloskey, Eugene; Dawson‐Hughes, Bess; Kaufman, Jean‐Marc; Laslop, Andrea; Petermans, Jean; Reginster, Jean‐Yves; Rizzoli, René; Robinson, Sian; Rolland, Yves; Rueda, Ricardo; Vellas, Bruno; Kanis, John A.

    2018-01-01

    Abstract Background All proposed definitions of sarcopenia include the measurement of muscle mass, but the techniques and threshold values used vary. Indeed, the literature does not establish consensus on the best technique for measuring lean body mass. Thus, the objective measurement of sarcopenia is hampered by limitations intrinsic to assessment tools. The aim of this study was to review the methods to assess muscle mass and to reach consensus on the development of a reference standard. Methods Literature reviews were performed by members of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis working group on frailty and sarcopenia. Face‐to‐face meetings were organized for the whole group to make amendments and discuss further recommendations. Results A wide range of techniques can be used to assess muscle mass. Cost, availability, and ease of use can determine whether the techniques are better suited to clinical practice or are more useful for research. No one technique subserves all requirements but dual energy X‐ray absorptiometry could be considered as a reference standard (but not a gold standard) for measuring muscle lean body mass. Conclusions Based on the feasibility, accuracy, safety, and low cost, dual energy X‐ray absorptiometry can be considered as the reference standard for measuring muscle mass. PMID:29349935

  14. Determination of the Static Anthropometric Characteristics of Iranian Microscope Users Via Regression Model

    Directory of Open Access Journals (Sweden)

    Toktam Balandeh

    2016-04-01

    Full Text Available Background: Anthropometry is a branch of Ergonomics that considers the measurement and description of the human body dimensions. Accordingly, equipment, environments, and workstations should be designed using user-centered design processes. Anthropometric dimensions differ considerably across gender, race, ethnicity and age, taking into account ergonomic and anthropometric principles. The aim of this study was to determine anthropometric characteristics of microscope users and provide a regression model for anthropometric dimensions. Methods: In this cross-sectional study, anthropometric dimensions (18 dimensions of the microscope users (N=174; 78 males and 96 females in Shiraz were measured. Instruments included a Studio meter, 2 type calipers, adjustable seats, a 40-cm ruler, a tape measure, and scales. The study data were analyzed using SPSS, version 20. Results: The means of male and female microscope users’ age were 31.64±8.86 and 35±10.9 years, respectively and their height were 161.03±6.87cm and 174.81±5.45cm, respectively. The results showed that sitting and standing eye height and sitting horizontal range of accessibility had a significant correlation with stature. Conclusion: The established anthropometric database can be used as a source for designing workstations for working with microscopes in this group of users. The regression analysis showed that three dimensions, i.e. standing eye height, sitting eye height, and horizontal range of accessibility sitting had a significant correlation with stature. Therefore, given one’s stature, these dimensions can be obtained with less measurement.

  15. Advisory Committee for the calibration standards of ionizing radiation measurement. Section 2. Radionuclide measurement

    International Nuclear Information System (INIS)

    1980-01-01

    Section II (Mesure des radionucleides) of Comite Consultatif pour les Etalons de Mesure des Rayonnements Ionisants held its fifth meeting in April 1979. The results of a full scale international comparison of 134 Cs and two limited comparisons of 137 Cs and 55 Fe were discussed. No other comparison is planned in the immediate future but a working group has been set up to study new projects. The BIPM international reference system for measuring the activity of gamma-ray emitters is working satisfactorily. Three working parties presented reports and a monograph in process of completion. BIPM described work recently carried out in field of interest and finally there was a brief exchange of information on the work in progress at the various laboratories represented at the meeting [fr

  16. Performance Measurement Implementation Of Minimum Service Standards For Basic Education Based On The Balanced Scorecard

    Directory of Open Access Journals (Sweden)

    Budiman Rusli

    2015-08-01

    Full Text Available Policies Minimum Service Standards for Basic Education has rolled out since 2002 by the minister in accordance with the Decree No. 129a U 2004 About Minimum Service Standards Education is continually updated and lastly Regulation of the Minister of Education and Culture No. 23 of 2013. All of the district government town should achieve the target of achieving 100 per cent in each of the indicators listed in the minimum service standards for the end of 2014. achievement pad on each indicator is just one measure of the performance of the local government department of education. Unfortunately from the announced target for 27 indicators that exist almost all regions including local governments do not reach Tangerang Regency. It is necessary for measuring the performance of local authorities particularly the education department. One performance measure modern enough that measurements can be done that The Balance Scorecard BSc. In the Balanced Scorecard is a management tool contemporare complete measure company performance not only of the financial perspective but also non-financial performance such as Customer Perspective Internal Business Processes and Learning and Growth. This approach is actually ideally suited for multinational companies because this approach requires very expensive but can be used to measure the profit performance of the company in addition to the combination of a long-term strategic and short-strategic. Balanced Scorecard it can also be done in measuring the performance of public sector services as well by modifying a few things so it can be used to measure the performance of the public sector including the Performance Measurement Minimum Service Standards for Basic Education.

  17. Detailed examination of 'standard elementary particle theories' based on measurement with Tristan

    International Nuclear Information System (INIS)

    Kamae, Tsuneyoshi

    1989-01-01

    The report discusses possible approaches to detailed analysis of 'standard elementary particle theories' on the basis of measurements made with Tristan. The first section of the report addresses major elementary particles involved in the 'standard theories'. The nature of the gauge particles, leptons, quarks and Higgs particle are briefly outlined. The Higgs particle and top quark have not been discovered, though the Higgs particle is essential in the Weiberg-Salam theory. Another important issue in this field is the cause of the collapse of the CP symmetry. The second section deals with problems which arise in universalizing the concept of the 'standard theories'. What are required to solve these problems include the discovery of supersymmetric particles, discovery of conflicts in the 'standard theories', and accurate determination of fundamental constants used in the 'standard theories' by various different methods. The third and fourth sections address the Weinberg-Salam theory and quantum chromodynamics (QCD). There are four essential parameters for the 'standard theories', three of which are associated with the W-S theory. The mass of the W and Z bosons measured in proton-antiproton collision experiments is compared with that determined by applying the W-S theory to electron-positron experiments. For QCD, it is essential to determine the lambda constant. (N.K.)

  18. Comparison of the gold standard of hemoglobin measurement with the clinical standard (BGA) and noninvasive hemoglobin measurement (SpHb) in small children: a prospective diagnostic observational study.

    Science.gov (United States)

    Wittenmeier, Eva; Bellosevich, Sophia; Mauff, Susanne; Schmidtmann, Irene; Eli, Michael; Pestel, Gunther; Noppens, Ruediger R

    2015-10-01

    Collecting a blood sample is usually necessary to measure hemoglobin levels in children. Especially in small children, noninvasively measuring the hemoglobin level could be extraordinarily helpful, but its precision and accuracy in the clinical environment remain unclear. In this study, noninvasive hemoglobin measurement and blood gas analysis were compared to hemoglobin measurement in a clinical laboratory. In 60 healthy preoperative children (0.2-7.6 years old), hemoglobin was measured using a noninvasive method (SpHb; Radical-7 Pulse Co-Oximeter), a blood gas analyzer (clinical standard, BGAHb; ABL 800 Flex), and a laboratory hematology analyzer (reference method, labHb; Siemens Advia). Agreement between the results was assessed by Bland-Altman analysis and by determining the percentage of outliers. Sixty SpHb measurements, 60 labHb measurements, and 59 BGAHb measurements were evaluated. In 38% of the children, the location of the SpHb sensor had to be changed more than twice for the signal quality to be sufficient. The bias/limits of agreement between SpHb and labHb were -0.65/-3.4 to 2.1 g·dl(-1) . Forty-four percent of the SpHb values differed from the reference value by more than 1 g·dl(-1) . Age, difficulty of measurement, and the perfusion index (PI) had no influence on the accuracy of SpHb. The bias/limits of agreement between BGAHb and labHb were 1.14/-1.6 to 3.9 g·dl(-1) . Furthermore, 66% of the BGAHb values differed from the reference values by more than 1 g·dl(-1) . The absolute mean difference between SpHb and labHb (1.1 g·dl(-1) ) was smaller than the absolute mean difference between BGAHb and labHb (1.5 g·dl(-1) /P = 0.024). Noninvasive measurement of hemoglobin agrees more with the reference method than the measurement of hemoglobin using a blood gas analyzer. However, both methods can show clinically relevant differences from the reference method (ClinicalTrials.gov: NCT01693016). © 2015 John Wiley & Sons Ltd.

  19. Reliability of linear distance measurement for dental implant length with standardized periapical radiographs

    International Nuclear Information System (INIS)

    Wakoh, Mamoru; Harada, Takuya; Otonari, Takamichi

    2006-01-01

    The purpose of this study was to investigate the accuracy of distance measurements of implant length based on periapical radiographs compared with that of other modalities. We carried out an experimental trial to compare precision in distance measurement. Dental implant fixtures were buried in the canine and first molar regions. These were then subjected to periapical (PE) radiography, panoramic (PA) radiography conventional (CV) and medical computed (CT) tomography. The length of the implant fixture on each film was measured by nine observers and degree of precision was statistically analyzed. The precision of both PE radiographs and CT tomograms was closest at the highest level. Standardized PE radiography, in particular, was superior to CT tomography in the first molar region. This suggests that standardized PE radiographs should be utilized as a reliable modality for longitudinal and linear distance measurement, depending on implant length at local implantation site. (author)

  20. Uncertainty analysis of standardized measurements of random-incidence absorption and scattering coefficients.

    Science.gov (United States)

    Müller-Trapet, Markus; Vorländer, Michael

    2015-01-01

    This work presents an analysis of the effect of some uncertainties encountered when measuring absorption or scattering coefficients in the reverberation chamber according to International Organization for Standardization/American Society for Testing and Materials standards. This especially relates to the uncertainty due to spatial fluctuations of the sound field. By analyzing the mathematical definition of the respective coefficient, a relationship between the properties of the chamber and the test specimen and the uncertainty in the measured quantity is determined and analyzed. The validation of the established equations is presented through comparisons with measurement data. This study analytically explains the main sources of error and provides a method to obtain the product of the necessary minimum number of measurement positions and the band center frequency to achieve a given maximum uncertainty in the desired quantity. It is shown that this number depends on the ratio of room volume to sample surface area and the reverberation time of the empty chamber.

  1. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  2. Hydrocarbon gas standards at the pmol/mol level to support ambient atmospheric measurements.

    Science.gov (United States)

    Rhoderick, George C; Duewer, David L; Ning, Li; DeSirant, Kathryn

    2010-02-01

    Studies of climate change increasingly recognize the diverse influences exerted by hydrocarbons in the atmosphere, including roles in particulates and ozone formation. Measurements of key non-methane hydrocarbons (NMHCs) suggest atmospheric concentrations ranging from low pmol/mol to nmol/mol, depending on location and compound. To accurately establish concentration trends and to relate measurement records from many laboratories and researchers, it is essential to have good calibration standards. Several of the world's National Metrology Institutes (NMIs) are developing primary and secondary reference gas standards at the nmol/mol level. While the U.S. NMI, the National Institute of Standards and Technology (NIST), has developed pmol/mol standards for halocarbons and some volatile organics, the feasibility of preparing well-characterized, stable standards for NMHCs at the pmol/mol level is not yet established. NIST recently developed a suite of primary standards by gravimetric dilution that contains 18 NMHCs covering the concentration range of 60 pmol/mol to 230 pmol/mol. Taking into account the small but chemically significant contribution of NMHCs in the high-purity diluent nitrogen used in their preparation, the relative concentrations and short-term stability (2 to 3 months) of these NMHCs in the primary standards have been confirmed by chromatographic analysis. The gravimetric values assigned from the methods used to prepare the materials and the analytical concentrations determined from chromatographic analysis generally agree to within +/-2 pmol/mol. However, anomalous results for several of the compounds reflect the difficulties inherent in avoiding contamination and making accurate measurements at these very low levels.

  3. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  4. Standard Test Method for Electronic Measurement for Hydrogen Embrittlement From Cadmium-Electroplating Processes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers an electronic hydrogen detection instrument procedure for measurement of plating permeability to hydrogen. This method measures a variable related to hydrogen absorbed by steel during plating and to the hydrogen permeability of the plate during post plate baking. A specific application of this method is controlling cadmium-plating processes in which the plate porosity relative to hydrogen is critical, such as cadmium on high-strength steel. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement, see Section 8. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

  5. Normal standards for kidney length as measured with US in premature infants

    International Nuclear Information System (INIS)

    Schlesinger, A.E.; Hedlund, G.L.; Pierson, W.P.; Null, D.M.

    1986-01-01

    In order to develop normal standards for kidney length in premature infants, the authors measured kidney length by US imaging in 39 (to date) premature infants less than 72 hours old and without known renal disease. Kidney length was compared with four different parameters of body size, including gestational age, birth weight, birth length, and body surface area. Similar standards have been generated previously for normal renal length as measured by US imaging in full-term infants and older children. These standards have proven utility in cases of congenital and acquired disorders that abnormally increase or decrease renal size. Scatter plots of kidney length versus body weight and kidney length versus body surface area conformed well to a logarithmic distribution, with a high correlation coefficient and close-fitting 95% confidence limits (SEE = 2.05)

  6. Standardization in dust emission measurement; Mesure des emissions de poussieres normalisation

    Energy Technology Data Exchange (ETDEWEB)

    Perret, R. [INERIS, 60 - Verneuil-en-Halatte, (France)

    1996-12-31

    The European Standardization Committee (CEN TC 264WG5) is developing a new reference method for measuring particulate emissions, suitable for concentrations inferior to 20 mg/m{sup 3} and especially for concentrations around 5 mg/m{sup 3}; the measuring method should be applicable to waste incinerator effluents and more generally to industrial effluents. Testing protocols and data analysis have been examined and repeatability and reproducibility issues are discussed

  7. Calibration and consistency of results of an ionization-chamber secondary standard measuring system for activity

    International Nuclear Information System (INIS)

    Schrader, Heinrich

    2000-01-01

    Calibration in terms of activity of the ionization-chamber secondary standard measuring systems at the PTB is described. The measurement results of a Centronic IG12/A20, a Vinten ISOCAL IV and a radionuclide calibrator chamber for nuclear medicine applications are discussed, their energy-dependent efficiency curves established and the consistency checked using recently evaluated radionuclide decay data. Criteria for evaluating and transferring calibration factors (or efficiencies) are given

  8. Actinide half-lives as standards for nuclear data measurements: current status

    International Nuclear Information System (INIS)

    Reich, C.W.

    1984-01-01

    The present status of knowledge of the half-life data for a number of long-lived actinide nuclides useful as standards for nuclear data measurements and reactor research and technology is summarized. The half-life information given draws heavily from the file of recommended decay data, generated over a number of years through the activities of an IAEA coordinated research program on the measurement and evaluation of transactinium-isotope nuclear decay data, whose work has recently been completed

  9. [Anthropometric indicators of obesity in the prediction of high body fat in adolescents].

    Science.gov (United States)

    Pelegrini, Andreia; Silva, Diego Augusto Santos; Silva, João Marcos Ferreira de Lima; Grigollo, Leoberto; Petroski, Edio Luiz

    2015-01-01

    To determine the anthropometric indicators of obesity in the prediction of high body fat in adolescents from a Brazilian State. The study included 1,197 adolescents (15-17 years old). The following anthropometric measurements were collected: body mass (weight and height), waist circumference and skinfolds (triceps and medial calf). The anthropometric indicators analyzed were: body mass index (BMI), waist circumference (WC), waist-to-height ratio (WHtR) and conicity index (C-Index). Body fat percentage, estimated by the Slaughter et al equation, was used as the reference method. Descriptive statistics, U Mann-Whitney test, and ROC curve were used for data analysis. Of the four anthropometric indicators studied, BMI, WHtR and WC had the largest areas under the ROC curve in relation to relative high body fat in both genders. The cutoffs for boys and girls, respectively, associated with high body fat were BMI 22.7 and 20.1 kg/m(2), WHtR 0.43 and 0.41, WC 75.7 and 67.7 cm and C-Index 1.12 and 1.06. Anthropometric indicators can be used in screening for identification of body fat in adolescents, because they are simple, have low cost and are non-invasive. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  10. Anthropometric Characteristics of Underprivileged Adolescents: A Study from Urban Slums of India

    Directory of Open Access Journals (Sweden)

    Sushama A. Khopkar

    2014-01-01

    Full Text Available Purpose. The anthropometric status and growth of adolescents living in challenging conditions such as slums are insufficiently studied. The purpose here was to describe anthropometric characteristics and nutritional status of adolescents from urban slums of India and to study the factors affecting it. Methods. Anthropometric, socioeconomic and dietary habit data were collected using structured questionnaires of six hundred adolescents aged 10–19 years by house-to-house survey conducted in two randomly selected slums of Nashik, Western India. The growth of adolescents was compared using WHO and Indian reference populations. Mixed effects logistic regression models were used to examine associations between anthropometric measures and income, mother’s education, household size, and dietary intake. Results. Prevalences of stunting and thinness were lower using the Indian reference population compared to that of WHO. Stunting was more prevalent than thinness in the study subjects, and boys suffered more than girls. The effect of age on stunting was different among boys than girls. A mother’s education was highly significantly associated with both stunting and thinness in both sexes. Household size and income were significantly associated with the nutritional status of girls. Conclusions. Educating mothers about the nutritional needs of adolescents may help to improve adolescents’ anthropometric profile and future health.

  11. Use of upper-arm anthropometry as measure of body-composition ...

    African Journals Online (AJOL)

    The anthropometric measurements of height, weight, triceps and mid-upper-arm circumference were recorded. The upper-arm composition was assessed using standard equations. Nutritional status was assessed using standard classification of upper-arm muscle-area by height (UAMAH) and thinness (low BMI-for-age).

  12. An Evaluation of Standardized Tests as Tools for the Measurement of Language Development.

    Science.gov (United States)

    Roberts, Elsa

    Four tests--PPVT, ITPA, MRT, WPPSI--commonly used to measure language development in young children are evaluated by four criteria: (1) what development aspects do they claim to tap; (2) what do they actually tap; (3) what linguistic knowledge is presupposed; (4) what special problems face a non-standard English speaker. These tests are considered…

  13. Development and Standardization of Inventory for Measuring Students' Integration into University Academic Culture

    Science.gov (United States)

    Esomonu, Nkechi Patricia-Mary; Okeaba, James Uzoma

    2016-01-01

    The study developed and standardized an Inventory for measuring Students' Integration into University Academic Culture named Inventory for Students' Integration into University Academic Culture (ISIUAC). The increase in dropout rates, substance use, cultism and other deviant behaviours in Nigerian universities makes it necessary for one to ask the…

  14. Measuring Course Competencies in a School of Business: The Use of Standardized Curriculum and Rubrics

    Science.gov (United States)

    Gibson, Jane Whitney

    2011-01-01

    This paper examines the growing emphasis on measurement of course competencies by individual college students through two course examples, an undergraduate course in managing change and conflict and a graduate course in human resource management. The author explains how standardized curriculum and assignment rubrics are being used to measure…

  15. Magnet measurement interfacing to the G-64 Euro standard bus and testing G-64 modules

    International Nuclear Information System (INIS)

    Hogrefe, R.L.

    1995-01-01

    The Magnet Measurement system utilizes various modules with a G-64 Euro (Gespac) Standard Interface. All modules are designed to be software controlled, normally under the constraints of the OS-9 operating system with all data transfers to a host computer accomplished by a serial link

  16. 30 CFR 202.353 - Measurement standards for reporting and paying royalties and direct use fees.

    Science.gov (United States)

    2010-07-01

    ... gallons to the nearest hundred gallons. (e) You need not report the quality of geothermal resources... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Measurement standards for reporting and paying royalties and direct use fees. 202.353 Section 202.353 Mineral Resources MINERALS MANAGEMENT SERVICE...

  17. The Relationship between Mean Square Differences and Standard Error of Measurement: Comment on Barchard (2012)

    Science.gov (United States)

    Pan, Tianshu; Yin, Yue

    2012-01-01

    In the discussion of mean square difference (MSD) and standard error of measurement (SEM), Barchard (2012) concluded that the MSD between 2 sets of test scores is greater than 2(SEM)[superscript 2] and SEM underestimates the score difference between 2 tests when the 2 tests are not parallel. This conclusion has limitations for 2 reasons. First,…

  18. An assessment of cellulose filters as a standardized material for measuring litter breakdown in headwater streams

    Science.gov (United States)

    The decay rate of cellulose filters and associated chemical and biological characteristics were compared to those of white oak (Quercus alba) leaves to determine if cellulose filters could be a suitable standardized material for measuring deciduous leaf breakdown in headwater str...

  19. Recent updates on the Standard Model Higgs boson measurements from the ATLAS and CMS experiments

    CERN Document Server

    Wang, Song-Ming

    2017-01-01

    This report presents the latest results from the ATLAS and CMS experiments on the measurements of the Standard Model Higgs boson by using the proton-proton collisions produced by the Large Hadron Collider during the first two years of Run 2 data taking.

  20. Internationally Comparable Measures of Occupational Status for the 1988 International Standard Classification of Occupations

    NARCIS (Netherlands)

    Ganzeboom, H.B.G.; Treiman, D.J.

    1996-01-01

    This paper provides operational procedures for coding internationally comparable measures of occupational status from the recently published International Standard Classification of Occupation 1988 (ISCO88) of the International Labor Office (ILO, 1990). We first discuss the nature of the ISCO88

  1. An International Standard Set of Patient-Centered Outcome Measures After Stroke

    NARCIS (Netherlands)

    Salinas, J. (Joel); Sprinkhuizen, S.M. (Sara M.); Ackerson, T. (Teri); Bernhardt, J. (Julie); Davie, C. (Charlie); George, M.G. (Mary G.); Gething, S. (Stephanie); Kelly, A.G. (Adam G.); Lindsay, P. (Patrice); Liu, L. (Liping); Martins, S.C.O. (Sheila C.O.); Morgan, L. (Louise); B. Norrving (Bo); Ribbers, G.M. (Gerard M.); Silver, F.L. (Frank L.); Smith, E.E. (Eric E.); Williams, L.S. (Linda S.); Schwamm, L.H. (Lee H.)

    2015-01-01

    markdownabstract__BACKGROUND AND PURPOSE:__ Value-based health care aims to bring together patients and health systems to maximize the ratio of quality over cost. To enable assessment of healthcare value in stroke management, an international standard set of patient-centered stroke outcome measures

  2. Abstracts from the fourth annual meeting of the council on ionizing radiation measurements and standards (CIRMS)

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    The Council on Ionizing Radiation Measurements and Standards held its fourth annual meeting at the National Institute of Standards and Technology, Gaithersburg, Maryland on November 28-30, 1995. The organization represents thousands of users of ionizing radiation and radioactive sources engaged in industrial radiation processing and sterilization, medical radiation diagnostics and therapy, nuclear power, and worker radiation protection programs. CIRMS provides a forum for discussing ionizing radiation issues; identifying, defining and prioritizing needed work; disseminating information on standards; and organizing workshops and meetings to advance ionizing radiation technology. Over 100 participants attended the meeting, which highlighted advanced techniques in radiation dosimetry and radioactivity measurements for the different ionizing radiation communities. Representatives attended from 28 corporations, 10 federal agencies, 8 national laboratories, 12 universities, and 1 state. Advanced techniques and future measurement needs were discussed in four sessions: (I) Medical Dosimetry, Radiology and Nuclear Medicine, (II) Occupational and Radiation Protection Dosimetry, (III) Measurement Techniques for Public and Environmental Radiation Protection, and (IV) Measurement Techniques for Radiation Effects on Materials. An additional session (Session V) was added to this annual meeting on the implementation of ISO 9000 for those CIRMS members involved in instrument and product manufacturing, and those providing radiation measurement services. Abstracts are also included from the poster session (Session VI) held on the final day of the meeting. The 4th Annual Meeting was organized by the Chairman of the Science and Technology Committee, Mr. Joseph C. McDonald of the Battelle Pacific Northwest Laboratory

  3. "First among Others? Cohen's ""d"" vs. Alternative Standardized Mean Group Difference Measures"

    Directory of Open Access Journals (Sweden)

    Sorel Cahan

    2011-06-01

    Full Text Available Standardized effect size measures typically employed in behavioral and social sciences research in the multi-group case (e.g., 2, f2 evaluate between-group variability in terms of either total or within-group variability, such as variance or standard deviation -' that is, measures of dispersion about the mean. In contrast, the definition of Cohen's d, the effect size measure typically computed in the two-group case, is incongruent due to a conceptual difference between the numerator -' which measures between-group variability by the intuitive and straightforward raw difference between the two group means -' and the denominator - which measures within-group variability in terms of the difference between all observations and the group mean (i.e., the pooled within-groups standard deviation, SW. Two congruent alternatives to d, in which the root square or absolute mean difference between all observation pairs is substituted for SW as the variability measure in the denominator of d, are suggested and their conceptual and statistical advantages and disadvantages are discussed.

  4. Anthropometric evaluation in diabetic patients with ischemic stroke

    Directory of Open Access Journals (Sweden)

    Holanda Maurus Marques de Almeida

    2006-01-01

    Full Text Available Strokes are one of the most common causes of mortality and long term severe disability. Risk factors for stroke include: age, gender, diabetes mellitus (DM, hypertension, and many others. OBJECTIVE: To evaluate obesity and hypertension in patients affected by acute ischemic stroke. METHOD: We compared the anthropometric variables between type II diabetic patients and non-diabetic patients. We evaluated a total of 60 patients, divided into two groups: 34 non-diabetic patients and a group of 26 type II diabetic subjects. RESULTS: The predominance of obesity, as well as hypertension, was very high among the studied groups, presenting no differences among the waist-hip ratio (WHR values of the study group compared to the ones of the control group. CONCLUSION: The predominance of obesity was very high among the studied groups and there was prevalence the android type obesity. There was no significative difference in the anthropometric evaluation by the measurement of WHR and the waist in the groups.

  5. Agreement in cardiovascular risk rating based on anthropometric parameters

    International Nuclear Information System (INIS)

    Dantas, Endilly Maria da Silva; Pinto, Cristiane Jordânia; Freitas, Rodrigo Pegado de Abreu; Medeiros, Anna Cecília Queiroz de

    2015-01-01

    To investigate the agreement in evaluation of risk of developing cardiovascular diseases based on anthropometric parameters in young adults. The study included 406 students, measuring weight, height, and waist and neck circumferences. Waist-to-height ratio and the conicity index. The kappa coefficient was used to assess agreement in risk classification for cardiovascular diseases. The positive and negative specific agreement values were calculated as well. The Pearson chi-square (χ 2 ) test was used to assess associations between categorical variables (p<0.05). The majority of the parameters assessed (44%) showed slight (k=0.21 to 0.40) and/or poor agreement (k<0.20), with low values of negative specific agreement. The best agreement was observed between waist circumference and waist-to-height ratio both for the general population (k=0.88) and between sexes (k=0.93 to 0.86). There was a significant association (p<0.001) between the risk of cardiovascular diseases and females when using waist circumference and conicity index, and with males when using neck circumference. This resulted in a wide variation in the prevalence of cardiovascular disease risk (5.5%-36.5%), depending on the parameter and the sex that was assessed. The results indicate variability in agreement in assessing risk for cardiovascular diseases, based on anthropometric parameters, and which also seems to be influenced by sex. Further studies in the Brazilian population are required to better understand this issue

  6. Anthropometric parameters as predictors of muscle mass in elderly women

    Directory of Open Access Journals (Sweden)

    Fábio da Silva Santana

    2015-08-01

    Full Text Available The aims of study were to analyze the relationship between muscle mass and anthropometric parameters in elderly women and to develop a mathematical model to predict muscle mass based on anthropometric parameters. The study included 63 elderly women (71.4 ± 4.4 years. Body weight, height, arm, waist, hip and calf circumferences were measured. Muscle mass was estimated using a densitometry. The muscle mass index was calculated using the equation (muscle mass index = muscle mass [kg] / height [m]². A significant correlation was found between muscle mass and body weight (r = 0.782, arm (r=0.688, waist (r=0.467, hip (r=0.629 and calf circumferences (r=0.592 with p<0.05 for all. Regression analysis indicated that body mass and calf circumference were independent predictors of muscle mass (r=0.81, r²=0.65, F=55.7. The prediction model obtained was muscle mass (kg=-0.543+(0.162*body mass+(0.151*calf circumference. No differences were observed between the amount of muscle mass and muscle mass index estimated by densitometry and by equation (p>0.05. The results of this study indicated that body mass, body mass index, arm, waist, hip and calf circumferences are related to muscle mass elderly women. The muscle mass can be adequately predicted based on data from body mass and calf circumference.

  7. On the road toward the development of clothing size standards and safety devices for Chilean workers.

    Science.gov (United States)

    Oñate, Esteban; Meyer, Felipe; Espinoza, Jorge

    2012-01-01

    The range of sizes used in Chile for clothing comes from criteria developed in continental Europe, mainly the EN 13402 standard. Any standard adopted by a country should consider the anthropometric dimensions of the user population, particularly to discern the ratio of garments for different size. Consequently, the purpose of this study was to propose standards for the size of clothing based on anthropometric characteristics of a sample of Chilean miners. The study was conducted in 447 male workers. The age and body weight were measured in each workers as well as their percentage of body fat. Anthropometric measurements for garments were made according to the criteria of the European Community (EN 13402-1) and ISO (8559- 1989). Body dimensions for the design of gloves, shoes, helmets and caps, clothes that cover the upper part of the body and clothes that cover the lower part were measured. The results obtained made it possible to establish the percentage of workers falling within the range of sizes that manufacturers consider as reference. One of the main conclusions of the study is the need to carefully consider a set of complementary anthropometric measures, which can help to improve the comfort of costumes, to the extent that the providers adapt their designs to the characteristics of Chilean workers.

  8. IMPACT OF PRENATAL MATERNAL FACTORS AND BIRTH ORDER ON THE ANTHROPOMETRIC STATUS OF NEWBORNS IN IRAN.

    Science.gov (United States)

    Kheirouri, Sorayya; Alizadeh, Mohammad

    2017-03-01

    This cross-sectional study was carried out to capture possible maternal factors affecting newborns' anthropometric measurements. Data were collected from eight public health centres and referral university hospital records in Tabriz and Heriss districts, north-west Iran, for 807 mother-neonate pairs delivering live singleton births and their offspring during the two years up to August 2014. The incidence of low birth weight (LBW) was 5.1%. A close correlation was found between maternal anthropometry and birth order with neonatal anthropometric data. Birth order and maternal height and body mass index (BMI) positively affected neonates' birth size (weight, length and head circumference). The rate of LBW was significantly higher for older (≥35 years), taller (≥170 cm), underweight (BMIbirth neonates. The results indicate that maternal anthropometric indices, age, iron intake and birth order influence the risk of LBW in newborns.

  9. THE IMPACT OF ANTHROPOMETRIC CHARACTERISTICS ON MANIFESTATION OF EXPLOSIVE STRENGTH IN VOLLEYBALL PLAYERS AGED 13 YEARS

    Directory of Open Access Journals (Sweden)

    Goran Nesic

    2006-04-01

    Full Text Available With the aim to investigate the plyometric training model used for the increase of explosive strength type (the vertical jump, an experimental research was carried out, drawing a sample of 40 volleyball players at the cadet level. For the purpose of this research, we applied nine anthropometric characteristics, which made the predictor system of variables. For the assessment of explosive strength, three tests were performed. The data were processed by descriptive and regression analyses. Based on the findings of the research and the discussion, one could unfailingly conclude that the applied system of anthropometric characteristics, as a predictor, has a significant impact on manifestation of explosive strength in volleyball players, aged 13 years, that is, it is possible to predict results of the tests of explosive strength based on the measures of anthropometric status of examinees.

  10. Body mass index and other anthropometric variables in children with sickle cell anaemia.

    Science.gov (United States)

    Odetunde, Odutola Israel; Chinawa, Josephat Maduabuchi; Achigbu, Kingsley Ihedioha; Achigbu, Eberechukwu O

    2016-01-01

    The objectives of this study were to determine the anthropometric variables of children with sickle cell anaemia and comparing it with those with normal haemoglobin genotype. A cross sectional study of anthropometric measurements was conducted over a period of six months. Children with sickle cell anaemia in steady state aged between 6-20 years were recruited. Nutritional assessment was done using anthropometrical variables. Data were analyzed using the Statistical Package for Social Sciences program (SPSS), version 20. The sickle cell patients comprised of 20 males and 20 females. There were an equal number of controls with an equal male to female ratio of 1:1. Forty eight percent (19) of the children with sickle cell anemia were underweight (sickle cell anemia were low when compared with children with normal Haemoglobin genotype.

  11. A survey on development of neutron standards and neutron measurement technique corresponding to various fields

    International Nuclear Information System (INIS)

    Matsumoto, Tetsuro

    2007-01-01

    Various uses of neutrons are being watched in many fields such as industry, medical technology and radiation protection. Especially, high energy neutrons above 15 MeV are important in a radiation exposure issue of an aircraft and a soft error issue of a semiconductor. Therefore neutron fluence standards for the high energy region are very important. However, the standards are not almost provided all over the world. Three reasons are mainly considered: (1) poor measurement techniques for the high energy neutrons, (2) a small number of high energy neutron facilities and (3) lack of nuclear data for high energy particle reactions. In this paper, the present status of the measurement techniques, the facilities and the nuclear data is investigated and discussed. In NMIJ/AIST, the 19.0-MeV neutron fluence standard will be established by 2010, and development of high energy neutron standards above 20 MeV is also examined. An outline of the development of the high energy neutron standards is also shown in this paper. (author)

  12. Foot Type Biomechanics Part 2: Are structure and anthropometrics related to function?

    Science.gov (United States)

    Mootanah, Rajshree; Song, Jinsup; Lenhoff, Mark W.; Hafer, Jocelyn F.; Backus, Sherry I.; Gagnon, David; Deland, Jonathan T.; Hillstrom, Howard J.

    2013-01-01

    Background Many foot pathologies are associated with specific foot types. If foot structure and function are related, measurement of either could assist with differential diagnosis of pedal pathologies. Hypothesis Biomechanical measures of foot structure and function are related in asymptomatic healthy individuals. Methods Sixty-one healthy subjects' left feet were stratified into cavus (n = 12), rectus (n = 27) and planus (n = 22) foot types. Foot structure was assessed by malleolar valgus index, arch height index, and arch height flexibility. Anthropometrics (height and weight), age, and walking speed were measured. Foot function was assessed by center of pressure excursion index, peak plantar pressure, maximum force, and gait pattern parameters. Foot structure and anthropometric variables were entered into stepwise linear regression models to identify predictors of function. Results Measures of foot structure and anthropometrics explained 10–37% of the model variance (adjusted R2) for gait pattern parameters. When walking speed was included, the adjusted R2 increased to 45–77% but foot structure was no longer a factor. Foot structure and anthropometrics predicted 7–47% of the model variance for plantar pressure and 16–64% for maximum force parameters. All multivariate models were significant (p Foot structure and function are related in asymptomatic healthy individuals. The structural parameters employed are basic measurements that do not require ionizing radiation and could be used in a clinical setting. Further research is needed to identify additional predictive parameters (plantar soft tissue characteristics, skeletal alignment, and neuromuscular control) and to include individuals with pathology. PMID:23107624

  13. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. On the measurement of the n