WorldWideScience

Sample records for standard angulated-slit method

  1. Reactor Section standard analytical methods. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Sowden, D.

    1954-07-01

    the Standard Analytical Methods manual was prepared for the purpose of consolidating and standardizing all current analytical methods and procedures used in the Reactor Section for routine chemical analyses. All procedures are established in accordance with accepted practice and the general analytical methods specified by the Engineering Department. These procedures are specifically adapted to the requirements of the water treatment process and related operations. The methods included in this manual are organized alphabetically within the following five sections which correspond to the various phases of the analytical control program in which these analyses are to be used: water analyses, essential material analyses, cotton plug analyses boiler water analyses, and miscellaneous control analyses.

  2. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  3. The Objective Borderline Method: A Probabilistic Method for Standard Setting

    Science.gov (United States)

    Shulruf, Boaz; Poole, Phillippa; Jones, Philip; Wilkinson, Tim

    2015-01-01

    A new probability-based standard setting technique, the Objective Borderline Method (OBM), was introduced recently. This was based on a mathematical model of how test scores relate to student ability. The present study refined the model and tested it using 2500 simulated data-sets. The OBM was feasible to use. On average, the OBM performed well…

  4. Standard-Setting Methods as Measurement Processes

    Science.gov (United States)

    Nichols, Paul; Twing, Jon; Mueller, Canda D.; O'Malley, Kimberly

    2010-01-01

    Some writers in the measurement literature have been skeptical of the meaningfulness of achievement standards and described the standard-setting process as blatantly arbitrary. We argue that standard setting is more appropriately conceived of as a measurement process similar to student assessment. The construct being measured is the panelists'…

  5. Cleanup standards and pathways analysis methods

    International Nuclear Information System (INIS)

    Devgun, J.S.

    1993-01-01

    Remediation of a radioactively contaminated site requires that certain regulatory criteria be met before the site can be released for unrestricted future use. Since the ultimate objective of remediation is to protect the public health and safety, residual radioactivity levels remaining at a site after cleanup must be below certain preset limits or meet acceptable dose or risk criteria. Release of a decontaminated site requires proof that the radiological data obtained from the site meet the regulatory criteria for such a release. Typically release criteria consist of a composite of acceptance limits that depend on the radionuclides, the media in which they are present, and federal and local regulations. In recent years, the US Department of Energy (DOE) has developed a pathways analysis model to determine site-specific soil activity concentration guidelines for radionuclides that do not have established generic acceptance limits. The DOE pathways analysis computer code (developed by Argonne National Laboratory for the DOE) is called RESRAD (Gilbert et al. 1989). Similar efforts have been initiated by the US Nuclear Regulatory Commission (NRC) to develop and use dose-related criteria based on genetic pathways analyses rather than simplistic numerical limits on residual radioactivity. The focus of this paper is radionuclide contaminated soil. Cleanup standards are reviewed, pathways analysis methods are described, and an example is presented in which RESRAD was used to derive cleanup guidelines

  6. Standardization of methods of maxillofacial roentgenology

    International Nuclear Information System (INIS)

    Rabukhina, N.A.; Arzhantsev, A.P.; Chikirdin, Eh.G.; Tombak, M.I.; Stavitskij, R.V.; Vasil'ev, Yu.D.

    1989-01-01

    Typical errors in teeth roentgenography reproduced in experiment, indicate that considerable disproportional distortions of images of anatomical structures which are decisive for radiodiagnosis, may occur in these cases. Standardization of intraoral roentgenography is based on a strict position of the patient's head, angle of inclination and alignment of a tube. Specialized R3-1 film should be used

  7. Antibody reactions methods in safety standards

    International Nuclear Information System (INIS)

    Shubik, V.M.; Sirasdinov, V.G.; Zasedatelev, A.A.; Kal'nitskij, S.A.; Livshits, R.E.

    1978-01-01

    Results of determinations are presented of autoantibodies in white rats to which the radionuclides 137 Cs, 226 Ra, and 90 Sr that show different distribution patterns in the body, have been administered chronically. Autoantiboby production is found to increase when the absorbed doses are close to or exceeding seven- to tenfold the maximum permissible values. The results obtained point to the desirability of autoantibody determination in studies aimed at setting hygienic standards for the absorption of radioactive substances

  8. Standardization of C-14 by tracing method

    Energy Technology Data Exchange (ETDEWEB)

    Koskinas, Marina F.; Kuznetsova, Maria; Yamazaki, Ione; Brancaccio, Franco; Dias, Mauro S., E-mail: koskinas@ipen.br, E-mail: marysmith@usp.br, E-mail: yamazaki@ipen.br, E-mail: fbrancac@ipen.br, E-mail: msdias@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The standardization of a {sup 14}C radioactive solution by means of the efficiency tracing technique is described. The {sup 14}C is a beta pure emitter with endpoint energy of 156 keV decaying to the ground state of {sup 14}N. The activity measurement was performed in a 4πβ-γ coincidence system, measuring the pure beta emitter mixed with a beta gamma emitter, which provides the beta detection efficiency. The radionuclide {sup 60}Co, which decays by beta particle followed by two gamma rays, was used as tracer and the efficiency was obtained by selecting the 1173 keV plus 1332 keV total energy absorption peak at the gamma channel. Known aliquots of the tracer, previously standardized by 4πβ (PC)-γ coincidence, were mixed with known aliquots of {sup 14}C. The sources of {sup 14}C + {sup 60}Co were prepared by dropping known aliquots from each radioactive solution. The events were registered by a Software Coincidence System (SCS). The activity of the solution was determined by using the extrapolation technique, changing the beta efficiency by pulse height discrimination. In order to determine the final activity, a Monte Carlo simulation was used to calculate the extrapolation curve. All the uncertainties involved were treated rigorously, by means of the covariance analysis methodology. Measurements using a HIDEX, a commercial liquid scintillator system, were carried out and the results were compared with the tracing technique, showing a good agreement. (author)

  9. Standard Testing Methods for Satellite Communication Systems

    OpenAIRE

    Stoner, Jerry

    2005-01-01

    University space programs continue to push the envelope of small satellite technology. Because budgets are often limited, and equipment costs can often be prohibitive to even well-established space programs, it becomes necessary to maximize the benefit/cost ratio of testing methods. Expensive testing is often not an option, nor is it realistic. Traditional methods such as anechoic chambers or antenna test ranges are not options, and testing the craft on the ground is not practical. Because of...

  10. Method for Constructing Standardized Simulated Root Canals.

    Science.gov (United States)

    Schulz-Bongert, Udo; Weine, Franklin S.

    1990-01-01

    The construction of visual and manipulative aids, clear resin blocks with root-canal-like spaces, for simulation of root canals is explained. Time, materials, and techniques are discussed. The method allows for comparison of canals, creation of any configuration of canals, and easy presentation during instruction. (MSE)

  11. Standardization of 57Co using different methods of LNMRI

    International Nuclear Information System (INIS)

    Rezende, E.A.; Lopes, R.T.; Silva, C.J. da; Poledna, R.; Silva, R.L. da; Tauhata, L.

    2015-01-01

    The activity of a 57 Co solution was determined using four LNMRI different measurement methods. The solution was standardized by live-timed anti-coincidence method and sum-peak method. The efficiency curve and standard-sample comparison methods were also used in this comparison. The results and their measurement uncertainties demonstrating the equivalence of these methods. As an additional contribution, the gamma emission probabilities of 57 Co were also determined. (author)

  12. Standard methods for analysis of phosphorus-32

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Methods are described for the determination of the radiochemical purity and the absolute disintegration rate of 32 P radioisotope preparations. The 32 P activity is determined by β counting, and other low-energy β radioactive contaminants are determined by aluminum-absorption curve data. Any γ-radioactive contaminants are determined by γ counting. Routine chemical testing is used to establish the chemical characteristics. The presence or absence of heavy metals is established by spot tests; free acid is determined by use of a pH meter; total solids are determined gravimetrically by evaporation and ignition at a temperature sufficient to evaporate the mineral acids, HCl and HNO 3 ; and nonvolatile matter, defined as that material which does not evaporate or ignite at a temperature sufficient to convert C to CO or CO 2 , is determined gravimetrically after such ignition

  13. Miscellaneous standard methods for Apis mellifera research

    DEFF Research Database (Denmark)

    Human, Hannelie; Brodschneider, Robert; Dietemann, Vincent

    2013-01-01

    and storing as well as determining individual weight of bees. The precise timing of developmental stages is also an important aspect of sampling individuals for experiments. In order to investigate and manipulate functional processes in honey bees, e. g. memory formation and retrieval and gene expression......, microinjection is often used. A method that is used by both researchers and beekeepers is the marking of queens that serves not only to help to locate her during her life, but also enables the dating of queens. Creating multiple queen colonies allows the beekeeper to maintain spare queens, increase brood...... production or ask questions related to reproduction. On colony level, very useful techniques are the measurement of intra hive mortality using dead bee traps, weighing of full hives, collecting pollen and nectar, and digital monitoring of brood development via location recognition. At the population level...

  14. Non-standard photography methods in audiovisual journalism

    OpenAIRE

    Géla, František

    2015-01-01

    The aim of the diploma thesis "Non- standard photography methods in audiovisual journalism" is to present image and production methods that are used in television news and journalism - particularly those ones that defy standard methods. These methods appear, considering technological development and the endeavour of making neutral visual space of television journalism, more attractive. First chapter of the thesis presents television news, its history, characteristics, elements and typology of...

  15. Standard methods for sampling freshwater fishes: Opportunities for international collaboration

    Science.gov (United States)

    Bonar, Scott A.; Mercado-Silva, Norman; Hubert, Wayne A.; Beard, Douglas; Dave, Göran; Kubečka, Jan; Graeb, Brian D. S.; Lester, Nigel P.; Porath, Mark T.; Winfield, Ian J.

    2017-01-01

    With publication of Standard Methods for Sampling North American Freshwater Fishes in 2009, the American Fisheries Society (AFS) recommended standard procedures for North America. To explore interest in standardizing at intercontinental scales, a symposium attended by international specialists in freshwater fish sampling was convened at the 145th Annual AFS Meeting in Portland, Oregon, in August 2015. Participants represented all continents except Australia and Antarctica and were employed by state and federal agencies, universities, nongovernmental organizations, and consulting businesses. Currently, standardization is practiced mostly in North America and Europe. Participants described how standardization has been important for management of long-term data sets, promoting fundamental scientific understanding, and assessing efficacy of large spatial scale management strategies. Academics indicated that standardization has been useful in fisheries education because time previously used to teach how sampling methods are developed is now more devoted to diagnosis and treatment of problem fish communities. Researchers reported that standardization allowed increased sample size for method validation and calibration. Group consensus was to retain continental standards where they currently exist but to further explore international and intercontinental standardization, specifically identifying where synergies and bridges exist, and identify means to collaborate with scientists where standardization is limited but interest and need occur.

  16. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  17. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  18. Standard Test Method for Environmental Resistance of Aerospace Transparencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers determination of the effects of exposure to thermal shock, condensing humidity, and simulated weather on aerospace transparent enclosures. 1.2 This test method is not recommended for quality control nor is it intended to provide a correlation to actual service life. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3.1 Exceptions—Certain inch-pound units are furnished in parentheses (not mandatory) and certain temperatures in Fahrenheit associated with other standards are also furnished. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Standard test methods of tension testing of metallic foil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1993-01-01

    1.1 These test methods cover the tension testing of metallic foil at room temperature in thicknesses less than 0.006 in. (0.150 mm). Note 1—Exception to these methods may be necessary in individual specifications or test methods for a particular material. 1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  1. Internal Standard Method for the Determination of Au and some ...

    African Journals Online (AJOL)

    Abstract. A method is described for the determination of Au, Pt, Pd, Ru and Rh in a converter matte sample, using inductively coupled plasma optical emission spectrometry (ICP-OES), with Y or Sc as internal standard. The results obtained by this method are discussed and compared with values obtained by an independent ...

  2. Standard test method for conducting potentiodynamic polarization resistance measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers an experimental procedure for polarization resistance measurements which can be used for the calibration of equipment and verification of experimental technique. The test method can provide reproducible corrosion potentials and potentiodynamic polarization resistance measurements. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Statistical methods for evaluating the attainment of cleanup standards

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, R.O.; Simpson, J.C.

    1992-12-01

    This document is the third volume in a series of volumes sponsored by the US Environmental Protection Agency (EPA), Statistical Policy Branch, that provide statistical methods for evaluating the attainment of cleanup Standards at Superfund sites. Volume 1 (USEPA 1989a) provides sampling designs and tests for evaluating attainment of risk-based standards for soils and solid media. Volume 2 (USEPA 1992) provides designs and tests for evaluating attainment of risk-based standards for groundwater. The purpose of this third volume is to provide statistical procedures for designing sampling programs and conducting statistical tests to determine whether pollution parameters in remediated soils and solid media at Superfund sites attain site-specific reference-based standards. This.document is written for individuals who may not have extensive training or experience with statistical methods. The intended audience includes EPA regional remedial project managers, Superfund-site potentially responsible parties, state environmental protection agencies, and contractors for these groups.

  4. Standardization of Laboratory Methods for the PERCH Study

    Science.gov (United States)

    Karron, Ruth A.; Morpeth, Susan C.; Bhat, Niranjan; Levine, Orin S.; Baggett, Henry C.; Brooks, W. Abdullah; Feikin, Daniel R.; Hammitt, Laura L.; Howie, Stephen R. C.; Knoll, Maria Deloria; Kotloff, Karen L.; Madhi, Shabir A.; Scott, J. Anthony G.; Thea, Donald M.; Adrian, Peter V.; Ahmed, Dilruba; Alam, Muntasir; Anderson, Trevor P.; Antonio, Martin; Baillie, Vicky L.; Dione, Michel; Endtz, Hubert P.; Gitahi, Caroline; Karani, Angela; Kwenda, Geoffrey; Maiga, Abdoul Aziz; McClellan, Jessica; Mitchell, Joanne L.; Morailane, Palesa; Mugo, Daisy; Mwaba, John; Mwansa, James; Mwarumba, Salim; Nyongesa, Sammy; Panchalingam, Sandra; Rahman, Mustafizur; Sawatwong, Pongpun; Tamboura, Boubou; Toure, Aliou; Whistler, Toni; O’Brien, Katherine L.; Murdoch, David R.

    2017-01-01

    Abstract The Pneumonia Etiology Research for Child Health study was conducted across 7 diverse research sites and relied on standardized clinical and laboratory methods for the accurate and meaningful interpretation of pneumonia etiology data. Blood, respiratory specimens, and urine were collected from children aged 1–59 months hospitalized with severe or very severe pneumonia and community controls of the same age without severe pneumonia and were tested with an extensive array of laboratory diagnostic tests. A standardized testing algorithm and standard operating procedures were applied across all study sites. Site laboratories received uniform training, equipment, and reagents for core testing methods. Standardization was further assured by routine teleconferences, in-person meetings, site monitoring visits, and internal and external quality assurance testing. Targeted confirmatory testing and testing by specialized assays were done at a central reference laboratory. PMID:28575358

  5. Standard test method for instrumented impact testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This standard establishes the requirements for performing instrumented Charpy V-Notch (CVN) and instrumented Miniaturized Charpy V-Notch (MCVN) impact tests on metallic materials. This method, which is based on experience developed testing steels, provides further information (in addition to the total absorbed energy) on the fracture behavior of the tested materials. Minimum requirements are given for measurement and recording equipment such that similar sensitivity and comparable total absorbed energy measurements to those obtained in Test Methods E 23 and E 2248 are achieved. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Toward a standard method for determination of waterborne radon

    International Nuclear Information System (INIS)

    Vitz, E.

    1990-01-01

    When the USEPA specifies the maximum contaminant level (MCL) for any contaminant, a standard method for analysis must be simultaneously stipulated. Promulgation of the proposed MCL and standard method for radon in drinking water is expected by early next year, but a six-month comment period and revision will precede final enactment. The standard method for radon in drinking water will probably specify that either the Lucas cell technique or liquid scintillation spectrometry be used. This paper reports results which support a standard method with the following features: samples should be collected by an explicitly stated technique to control degassing, in glass vials with or without scintillation cocktail, and possibly in duplicate; samples should be measured by liquid scintillation spectroscopy in a specified energy window', in a glass vial with particular types of cocktails; radium standards should be prepared with controlled quench levels and specified levels of carriers, but radium-free controls prepared by a specified method should be used in interlaboratory comparison studies

  7. Standardized methods for photography in procedural dermatology using simple equipment.

    Science.gov (United States)

    Hexsel, Doris; Hexsel, Camile L; Dal'Forno, Taciana; Schilling de Souza, Juliana; Silva, Aline F; Siega, Carolina

    2017-04-01

    Photography is an important tool in dermatology. Reproducing the settings of before photos after interventions allows more accurate evaluation of treatment outcomes. In this article, we describe standardized methods and tips to obtain photographs, both for clinical practice and research procedural dermatology, using common equipment. Standards for the studio, cameras, photographer, patients, and framing are presented in this article. © 2017 The International Society of Dermatology.

  8. Standard Test Method for Abrasive Wear Resistance of Cemented

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of abrasive wear resistance of cemented carbides. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units are in parentheses and may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard Test Method for Measured Speed of Oil Diffusion Pumps

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the determination of the measured speed (volumetric flow rate) of oil diffusion pumps. 1.2 The values stated in inch-pound units are to be regarded as the standard. The metric equivalents of inch-pound units may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard Test Method for Determining Poisson's Ratio of Honeycomb Cores

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the honeycomb Poisson's ratio from the anticlastic curvature radii, see . 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Standard Test Method for Shear Fatigue of Sandwich Core Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers determination of the effect of repeated shear loads on sandwich core materials. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Standard Test Method for Dimensional Stability of Sandwich Core Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the sandwich core dimensional stability in the two plan dimensions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Statistical benchmarking in utility regulation: Role, standards and methods

    International Nuclear Information System (INIS)

    Newton Lowry, Mark; Getachew, Lullit

    2009-01-01

    Statistical benchmarking is being used with increasing frequency around the world in utility rate regulation. We discuss how and where benchmarking is in use for this purpose and the pros and cons of regulatory benchmarking. We then discuss alternative performance standards and benchmarking methods in regulatory applications. We use these to propose guidelines for the appropriate use of benchmarking in the rate setting process. The standards, which we term the competitive market and frontier paradigms, have a bearing on method selection. These along with regulatory experience suggest that benchmarking can either be used for prudence review in regulation or to establish rates or rate setting mechanisms directly

  14. Standard Test Method for Thermal Oxidative Resistance of Carbon Fibers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the apparatus and procedure for the determination of the weight loss of carbon fibers, exposed to ambient hot air, as a means of characterizing their oxidative resistance. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units which are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard information, see Section 8.

  15. Robust steganographic method utilizing properties of MJPEG compression standard

    Directory of Open Access Journals (Sweden)

    Jakub Oravec

    2015-06-01

    Full Text Available This article presents design of steganographic method, which uses video container as cover data. Video track was recorded by webcam and was further encoded by compression standard MJPEG. Proposed method also takes in account effects of lossy compression. The embedding process is realized by switching places of transform coefficients, which are computed by Discrete Cosine Transform. The article contains possibilities, used techniques, advantages and drawbacks of chosen solution. The results are presented at the end of the article.

  16. Report on the Standardization Project "Formal Methods in Conformance Testing"

    NARCIS (Netherlands)

    Baumgarten, B.; Hogrefe, D.; Heymer, S.; Burkhardt, H.-J.; Giessler, A.; Tretmans, G.J.

    1996-01-01

    This paper presents the latest developments in the “Formal Methods in Conformance Testing��? (FMCT) project of ISO and ITU–T. The project has been initiated to study the role of formal description techniques in the conformance testing process. The goal is to develop a standard that defines the

  17. Standard methods for rearing and selection of Apis mellifera queens

    DEFF Research Database (Denmark)

    Büchler, Ralph; Andonov, Sreten; Bienefeld, Kaspar

    2013-01-01

    Here we cover a wide range of methods currently in use and recommended in modern queen rearing, selection and breeding. The recommendations are meant to equally serve as standards for both scientific and practical beekeeping purposes. The basic conditions and different management techniques for q...

  18. Evaluating the Capacity of Standard Investment Appraisal Methods

    NARCIS (Netherlands)

    M.M. Akalu

    2002-01-01

    textabstractThe survey findings indicate the existence of gap between theory and practice of capital budgeting. Standard appraisal methods have shown a wider project value discrepancy, which is beyond and above the contingency limit. In addition, the research has found the growing trend in the use

  19. Internal standard method for the determination of Gold and the ...

    African Journals Online (AJOL)

    Olof Vorster

    demand the world over for gold (Au) and the platinum group metals (PGMs) consisting of Pt, Pd, Ru, Rh, Ir and Os. Inductively coupled plasma optical emission spectrometry (ICP-OES) is widely used for the quantitative analysis of the PGMs using the internal standardization method.2,9. Although interferences are less of a.

  20. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Effectiveness of permethrin standard and modified methods in scabies treatment

    Directory of Open Access Journals (Sweden)

    Saleha Sungkar

    2014-06-01

    Full Text Available Background: Permethrin is the drug of choice for scabies with side effects such as erythema, pain, itching and prickling sensation. Whole-body (standard topical application of permethrin causes discomfort; thus, modified application of permethrin to the lesion only, followed with baths twice daily using soap was proposed. The objective of the study is to know the effectiveness of standard against lesion-only application of permethrin in scabies treatment.Methods: An experimental study was conducted in pesantren in East Jakarta and data was collected in May-July 2012. Diagnosis of scabies was made through anamnesis and skin examination. Subjects positive for scabies were divided into three groups: one standard method group (whole-body topical application and two modified groups (lesion-only application followed by the use of regular soap and antiseptic soap group. The three groups were evaluated weekly for three consecutive weeks. Data was processed using SPSS 20 and analyzed by Kruskal-Wallis test.Results: Total of 94 subjects was scabies positive (prevalence 50% but only 69 subjects were randomly picked to be analyzed. The cure rate at the end of week III of the standard method group was 95.7%, modified treatment followed by the use of regular soap was 91.3%, and modified treatment followed by the use of antiseptic soap was 78.3% (p = 0.163. The recurrence rate of standard treatment was 8.7%,  modified treatment followed by the use of regular soap was 13% and modified treatment followed by the use of antiseptic soap was 26.1% (p = 0.250.Conclusion: The standard scabies treatment was as effective as the modified scabies treatment.

  2. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  3. Pneumatic gouge versus standard method for iliac crest harvesting.

    Science.gov (United States)

    Duncan, R W; McGuire, R A; Meydrech, E F

    1994-08-01

    Fifty consecutive patients undergoing posterior lumbar fusion by a single surgeon were prospectively randomized in a study designed to evaluate the efficacy of using a pneumatic oscillating gouge to obtain posterior outer table iliac crest bone graft versus the standard method of using osteotomes and gouges. Variables analyzed included graft harvesting time, blood loss, weight of graft obtained, and graft site morbidity. Mean graft harvesting time with the pneumatic gouge was 1 minute 44 seconds (range, 1 min 5 sec to 3 min 15 sec) compared with the standard method time of 4 minutes 4 seconds (range, 2 min 15 sec to 8 min 56 sec) (P = 0.0001). Blood loss was also less, with a mean of 25.4 cc for the pneumatic gouge compared with 65.2 cc using the standard method (P = 0.0001). There were no complications with the graft site in either group. We conclude that the pneumatic gouge is a viable alternative to standard bone graft harvesting techniques. Benefits include shorter operative time and decreased blood loss without an increased morbidity.

  4. Standard Test Method for Isotopic Analysis of Uranium Hexafluoride by Single-Standard Gas Source Multiple Collector Mass Spectrometer Method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the isotopic analysis of uranium hexafluoride (UF6) with 235U concentrations less than or equal to 5 % and 234U, 236U concentrations of 0.0002 to 0.1 %. 1.2 This test method may be applicable to the analysis of the entire range of 235U isotopic compositions providing that adequate Certified Reference Materials (CRMs or traceable standards) are available. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard Test Method for Laboratory Aging of Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the resistance of sandwich panels to severe exposure conditions as measured by the change in selected properties of the material after exposure. The exposure cycle to which the specimen is subjected is an arbitrary test having no correlation with natural weathering conditions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Standard test method for macroetching metals and alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 These test procedures describe the methods of macro- etching metals and alloys to reveal their macrostructure. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.2, 7.1, 8.1.3, 8.2.1, 8.8.3, 8.10.1.1, and 8.13.2.

  7. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  8. Quantitative data standardization of X-ray based densitometry methods

    Science.gov (United States)

    Sergunova, K. A.; Petraikin, A. V.; Petrjajkin, F. A.; Akhmad, K. S.; Semenov, D. S.; Potrakhov, N. N.

    2018-02-01

    In the present work is proposed the design of special liquid phantom for assessing the accuracy of quantitative densitometric data. Also are represented the dependencies between the measured bone mineral density values and the given values for different X-ray based densitometry techniques. Shown linear graphs make it possible to introduce correction factors to increase the accuracy of BMD measurement by QCT, DXA and DECT methods, and to use them for standardization and comparison of measurements.

  9. Comparison of Standard and Fast Charging Methods for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Petr Chlebis

    2014-01-01

    Full Text Available This paper describes a comparison of standard and fast charging methods used in the field of electric vehicles and also comparison of their efficiency in terms of electrical energy consumption. The comparison was performed on three-phase buck converter, which was designed for EV’s fast charging station. The results were obtained by both mathematical and simulation methods. The laboratory model of entire physical application, which will be further used for simulation results verification, is being built in these days.

  10. Study on method of data standardization in interferometric testing

    Science.gov (United States)

    Chen, Wei

    2010-10-01

    As a rule, Interferometers are used to test the figure in the polishing phase of optical component, it could provide advance tutor suggestion for manufacturing. It is unable to get the whole wave-front interferogram usually because phase-shift Interferometry is sensitive to environment vibration, so the exactly interference data of the optical surface could not be obtained. Various spatial point on the tested optical component will be given by calculation method about arithmetic average value of equal accuracy is provied. This paper describes the testing results of optical components in size Φ1200mm, it is proved the method could eliminate the vibration effectively and get the standardization data.

  11. Cutibacterium acnes molecular typing: time to standardize the method.

    Science.gov (United States)

    Dagnelie, M-A; Khammari, A; Dréno, B; Corvec, S

    2018-03-12

    The Gram-positive, anaerobic-aerotolerant bacterium Cutibacterium acnes is a commensal of human healthy skin, subdivided into six main phylogenetic groups or phylotypes: IA1, IA2, IB, IC, II and III. To decipher how far C. acnes specific subgroups are involved in disease physiopathology, different molecular typing methods have been developed to identify these subgroups (i.e. phylotypes, clonal complexes, SLST-types). However, as there were several molecular typing methods developed over the last decade, comparing the results from one article to another became a difficult task. Based on the scientific literature, the aim of this narrative review is to propose a standardized method to perform C. acnes molecular typing, according to the degree of resolution needed (phylotypes, clonal complexes, or SLST-types). We discuss the different typing methods existing with a critical point of view, raising the advantages/drawbacks, and identify the most frequently used. Consequently, we propose a consensus algorithm according to the needed phylogeny resolution level. We first propose to use multiplex PCR for phylotype identification, MLST9 for clonal complex determination, and SLST for phylogeny investigation including numerous isolates. There is an obvious need to create a consensus about C. acnes molecular typing methods. This standardization will facilitate the comparison of the results from one article to another, and also the interpretations of clinical data. Copyright © 2018. Published by Elsevier Ltd.

  12. An endogenous standard, radioisotopic ratio method in NAA

    International Nuclear Information System (INIS)

    Byrne, A.R.; Dermelj, M.

    1997-01-01

    A derivative form of NAA is proposed which is based on the use of an endogenous internal standard of already known concentration in the sample. If a comparator with a known ratio of the determinand and endogenous standard are co-irradiated with the sample, the determinand concentration is derived in terms of the endogenous standard concentration and the activity ratios of the two induced nuclides in the sample and comparator. As well as eliminating the sample mass and greatly reducing errors caused by pulse pile-up and geometrical differences, it was shown that in the radiochemical mode, if the endogenous standard is chosen so that the induced activity is radioisotopic with that from the determinand, the radiochemical yield is also eliminated and the risk non-achievement of isotopic exchange greatly reduced. The method is demonstrated with good results on reference materials for the determination of I, Mn and Ni. The advantages and disadvantages of this approach are discussed. It is suggested that it may be of application in quality control and in extending the range of certified elements in reference materials. (author)

  13. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  14. 49V Standardization by the CIEMAT/NIST LSC method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos, J.M.; Jimenez, A.; Ortiz, F.

    1998-01-01

    The sample preparation procedure for LSC standardization of a solution of 49 VCl 5 is described and the time stability of samples is analyzed in four commercial scintillators, HiSafe II, HiSafe III, Ultima-Gold and Insta-Gel Plus. Acceptable stability was obtained in HiSafe III and Ultima-Gold. A self-consistent procedure was developed and successfully applied to the determination of the activity concentration of 49 V. The samples were standardized by the CIEMAT/NIST method to a combined uncertainty of 3.4% in the interval of figure of merit 1.2-2.5 ( 3 H equivalent efficiency 40%-20%)

  15. Improving healthcare middleware standards with semantic methods and technologies.

    Science.gov (United States)

    Román, Isabel; Calvillo, Jorge; Roa, Laura M; Madinabeitia, Germán

    2008-01-01

    A critical issue in healthcare informatics is to facilitate the integration and interoperability of applications. This goal can be achieved through an open architecture based on a middleware independent from specific applications; useful for working with existing systems, as well as for the integration of new systems. Several standard organizations are making efforts toward this target. This work is based on the EN 12967-1,2,3, developed by CEN, that follows the ODP (Open Distributed Processing) methodology, providing a specification of distributed systems based on the definition of five viewpoints. However, only the three upper viewpoints are used to produce EN 12967, the two lower viewpoints should be considered in the implementation context. We are using Semantic Grid for lower views and Semantic Web and Web Services for the definition of the upper views. We analyze benefits of using these methods and technologies and expose methodology for the development of this semantic healthcare middleware observing European Standards.

  16. THE STANDARDIZED CANDLE METHOD FOR TYPE II PLATEAU SUPERNOVAE

    International Nuclear Information System (INIS)

    Olivares E, Felipe; Hamuy, Mario; Pignata, Giuliano; Maza, Jose; Bersten, Melina; Phillips, Mark M.; Morrel, Nidia I.; Suntzeff, Nicholas B.; Filippenko, Alexei V.; Kirshner, Robert P.; Matheson, Thomas

    2010-01-01

    In this paper, we study the 'standardized candle method' using a sample of 37 nearby (redshift z V ) = 0.2 mag. The correlation between plateau luminosity and expansion velocity previously reported in the literature is recovered. Using this relation and assuming a standard reddening law (R V = 3.1), we obtain Hubble diagrams (HDs) in the BVI bands with dispersions of ∼0.4 mag. Allowing R V to vary and minimizing the spread in the HDs, we obtain a dispersion range of 0.25-0.30 mag, which implies that these objects can deliver relative distances with precisions of 12%-14%. The resulting best-fit value of R V is 1.4 ± 0.1.

  17. Standard CMMIsm Appraisal Method for Process Improvement (SCAMPIsm), Version 1.1: Method Definition Document

    National Research Council Canada - National Science Library

    2001-01-01

    The Standard CMMI Appraisal Method for Process Improvement (SCAMPI(Service Mark)) is designed to provide benchmark quality ratings relative to Capability Maturity Model(registered) Integration (CMMI(Service Mark)) models...

  18. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  19. The eXtensible Access Method (XAM Standard

    Directory of Open Access Journals (Sweden)

    Steve Todd

    2009-10-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 Recent developments in the storage industry have resulted in the creation of an industry standard application programmer’s interface (API known as XAM, the eXtensible Access Method. The XAM API focuses on the creation and management of reference information (otherwise known as fixed content. Storage vendors supporting the XAM API will provide new benefits to applications that are creating and managing large amounts of fixed content. The benefits described by this paper merit consideration and research by developers creating applications for Digital Curators.

  20. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  1. Standard Test Method for Cavitation Erosion Using Vibratory Apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the production of cavitation damage on the face of a specimen vibrated at high frequency while immersed in a liquid. The vibration induces the formation and collapse of cavities in the liquid, and the collapsing cavities produce the damage to and erosion (material loss) of the specimen. 1.2 Although the mechanism for generating fluid cavitation in this method differs from that occurring in flowing systems and hydraulic machines (see 5.1), the nature of the material damage mechanism is believed to be basically similar. The method therefore offers a small-scale, relatively simple and controllable test that can be used to compare the cavitation erosion resistance of different materials, to study in detail the nature and progress of damage in a given material, or—by varying some of the test conditions—to study the effect of test variables on the damage produced. 1.3 This test method specifies standard test conditions covering the diameter, vibratory amplitude and frequency of the...

  2. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  3. Standard test method for K-R curve determination

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of the resistance to fracture of metallic materials under Mode I loading at static rates using either of the following notched and precracked specimens: the middle-cracked tension M(T) specimen or the compact tension C(T) specimen. A K-R curve is a continuous record of toughness development (resistance to crack extension) in terms of KR plotted against crack extension in the specimen as a crack is driven under an increasing stress intensity factor, K. 1.2 Materials that can be tested for K-R curve development are not limited by strength, thickness, or toughness, so long as specimens are of sufficient size to remain predominantly elastic to the effective crack extension value of interest. 1.3 Specimens of standard proportions are required, but size is variable, to be adjusted for yield strength and toughness of the materials. 1.4 Only two of the many possible specimen types that could be used to develop K-R curves are covered in this method. 1.5 The test is app...

  4. Establishing the standard method of cochlear implant in Rongchang pig.

    Science.gov (United States)

    Chen, Wei; Yi, Haijin; Zhang, Liang; Ji, Fei; Yuan, Shuolong; Zhang, Yue; Ren, Lili; Li, Jianan; Chen, Lei; Guo, Weiwei; Yang, Shiming

    2017-05-01

    In this investigation, a large mammal, Rongchang pigs were used to successfully establish a research platform for cochlear implant study on the routine use of it in clinic. The aim of this study was to establish a standard method of cochlear implant in a large mammal-pig. Rongchang pigs were selected, then divided into two groups: normal-hearing group (Mitf +/+) and mutation group with hearing loss (Mitf -/-). Cochlear implants were used and ABR and EABR were recorded. The implanted electrodes were observed by X-ray and HE stains. The success with cochlear implant and the best electrode position could be defined in all animals, the coiling of the cochlea reached 1.5-1.75 turns. Immediately after the operation of cochlear implants, the ABR threshold of the operated ear (right) could not be derived for each frequency at 120 dB SPL. Moreover, 7 days after surgery, the low-frequency ABR threshold of the operated ear (right) could be derived partly at 100 dB SPL, but the high-frequency ABR threshold could not be derived at 120 dB SPL. Immediately or 1 week after cochlear implants, the EABR threshold was 90 CL in the Mitf +/+ group. This was obviously lower than the 190 CL in the Mitf -/- group.

  5. A Method for Developing Standard Patient Education Program.

    Science.gov (United States)

    Lura, Carolina Bryne; Hauch, Sophie Misser Pallesgaard; Gøeg, Kirstine Rosenbeck; Pape-Haugaard, Louise

    2018-01-01

    In Denmark, patients being treated on Haematology Outpatients Departments get instructed to self-manage their blood sample collection from Central Venous Catheter (CVC). However, this is a complex and risky procedure, which can jeopardize patient safety. The aim of the study was to suggest a method for developing standard digital patient education programs for patients in self-administration of blood samples drawn from CVC. The Design Science Research Paradigm was used to develop a digital patient education program, called PAVIOSY, to increase patient safety during execution of the blood sample collection procedure by using videos for teaching as well as procedural support. A step-by-step guide was developed and used as basis for making the videos. Quality assurance through evaluation with a nurse was conducted on both the step-by-step guide and the videos. The quality assurance evaluation of the videos showed; 1) Errors due to the order of the procedure can be determined by reviewing the videos despite that the guide was followed. 2) Videos can be used to identify errors - important for patient safety - in the procedure, which are not identifiable in a written script. To ensure correct clinical content of the educational patient system, health professionals must be engaged early in the development of content and design phase.

  6. [Precautions of physical performance requirements and test methods during product standard drafting process of medical devices].

    Science.gov (United States)

    Song, Jin-Zi; Wan, Min; Xu, Hui; Yao, Xiu-Jun; Zhang, Bo; Wang, Jin-Hong

    2009-09-01

    The major idea of this article is to discuss standardization and normalization for the product standard of medical devices. Analyze the problem related to the physical performance requirements and test methods during product standard drafting process and make corresponding suggestions.

  7. THE STANDARD SINGLE COST METHOD AND THE EFFICIENCY OF INDUSTRIAL COMPANIES’ MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Claudiu C. CONSTANTINESCU

    2008-12-01

    Full Text Available This article briefly describes the premises for the application of the standard direct cost calculation method in industry, the standard single cost calculation method, the stages of standard cost calculation per product and the calculation methods of standards per product. It also briefly underlines the possibilities of cost calculation and monitoring of deviation of the costs of raw materials and other materials as compared to the pre-established standard costs.

  8. Standard test method for atom percent fission in uranium and plutonium fuel (Neodymium-148 Method)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the determination of stable fission product 148Nd in irradiated uranium (U) fuel (with initial plutonium (Pu) content from 0 to 50 %) as a measure of fuel burnup (1-3). 1.2 It is possible to obtain additional information about the uranium and plutonium concentrations and isotopic abundances on the same sample taken for burnup analysis. If this additional information is desired, it can be obtained by precisely measuring the spike and sample volumes and following the instructions in Test Method E267. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard test method for distribution coefficients of inorganic species by the batch method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of distribution coefficients of chemical species to quantify uptake onto solid materials by a batch sorption technique. It is a laboratory method primarily intended to assess sorption of dissolved ionic species subject to migration through pores and interstices of site specific geomedia. It may also be applied to other materials such as manufactured adsorption media and construction materials. Application of the results to long-term field behavior is not addressed in this method. Distribution coefficients for radionuclides in selected geomedia are commonly determined for the purpose of assessing potential migratory behavior of contaminants in the subsurface of contaminated sites and waste disposal facilities. This test method is also applicable to studies for parametric studies of the variables and mechanisms which contribute to the measured distribution coefficient. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement a...

  10. 29 CFR 1630.7 - Standards, criteria, or methods of administration.

    Science.gov (United States)

    2010-07-01

    ... Standards, criteria, or methods of administration. It is unlawful for a covered entity to use standards, criteria, or methods of administration, which are not job-related and consistent with business necessity... 29 Labor 4 2010-07-01 2010-07-01 false Standards, criteria, or methods of administration. 1630.7...

  11. Standard test method for determining atmospheric chloride deposition rate by wet candle method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a wet candle device and its use in measuring atmospheric chloride deposition (amount of chloride salts deposited from the atmosphere on a given area per unit time). 1.2 Data on atmospheric chloride deposition can be useful in classifying the corrosivity of a specific area, such as an atmospheric test site. Caution must be exercised, however, to take into consideration the season because airborne chlorides vary widely between seasons. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Standard or Dialect? A new online elicitation method

    NARCIS (Netherlands)

    Sloos, Marjoleine

    2012-01-01

    In dialectology, it is often necessary to obtain a measure for the level of dialectal accent shown by individual speakers, especially if statistical analysis is needed. This also applies to studies on standard variants which are "coloured" by regiolects or dialects. In this paper I explore the

  13. Measurement Methods for Humeral Retroversion Using Two-Dimensional Computed Tomography Scans: Which Is Most Concordant with the Standard Method?

    Science.gov (United States)

    Oh, Joo Han; Kim, Woo; Cayetano, Angel A

    2017-06-01

    Humeral retroversion is variable among individuals, and there are several measurement methods. This study was conducted to compare the concordance and reliability between the standard method and 5 other measurement methods on two-dimensional (2D) computed tomography (CT) scans. CT scans from 21 patients who underwent shoulder arthroplasty (19 women and 2 men; mean age, 70.1 years [range, 42 to 81 years]) were analyzed. The elbow transepicondylar axis was used as a distal reference. Proximal reference points included the central humeral head axis (standard method), the axis of the humeral center to 9 mm posterior to the posterior margin of the bicipital groove (method 1), the central axis of the bicipital groove -30° (method 2), the base axis of the triangular shaped metaphysis +2.5° (method 3), the distal humeral head central axis +2.4° (method 4), and contralateral humeral head retroversion (method 5). Measurements were conducted independently by two orthopedic surgeons. The mean humeral retroversion was 31.42° ± 12.10° using the standard method, and 29.70° ± 11.66° (method 1), 30.64° ± 11.24° (method 2), 30.41° ± 11.17° (method 3), 32.14° ± 11.70° (method 4), and 34.15° ± 11.47° (method 5) for the other methods. Interobserver reliability and intraobserver reliability exceeded 0.75 for all methods. On the test to evaluate the equality of the standard method to the other methods, the intraclass correlation coefficients (ICCs) of method 2 and method 4 were different from the ICC of the standard method in surgeon A ( p method 2 and method 3 were different form the ICC of the standard method in surgeon B ( p method 1) would be most concordant with the standard method even though all 5 methods showed excellent agreements.

  14. Comparative evaluation of different methods of setting hygienic standards

    International Nuclear Information System (INIS)

    Ramzaev, P.V.; Rodionova, L.F.; Mashneva, N.I.

    1978-01-01

    Long-term experiments were carried out on white mice and rats to study the relative importance of various procedures used in setting hygienic standards for exposure to adverse factors. A variety of radionuclides and chemical substances were tested and the sensitivities to them of various indices of the bodily state were determined. For each index, statistically significant minimal effective concentrations of substances were established

  15. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  16. The Standard Days Method: an addition to the arsenal of family planning method choice in Ethiopia.

    Science.gov (United States)

    Bekele, Biruhtesfa; Fantahun, Mesganaw

    2012-07-01

    The Standard Days Method ® (SDM) is a fertility awareness-based method of family planning that helps users to identify the fertile days of the reproductive cycle (Days 8-19). To prevent pregnancy users avoid unprotected sexual intercourse during these days. A cross-sectional community-based study was conducted from December 2007 to June 2008 in four operational areas of Pathfinder International Ethiopia. A total of 184 SDM users were included in the study. Quantitative and qualitative methods of data collection were used. The aim of the study was to examine the experience of introducing the SDM at community level in Ethiopia. Of the 184 participants, 80.4% were still using the SDM at the time of the survey, with 35% having used it for between 6 and 12 months, while 42% had used it for more than a year. The majority (83%) knew that a woman is most likely to conceive halfway through her menstrual cycle, and nearly 91% correctly said that the SDM does not confer protection from sexually transmitted infections/AIDS. A substantial majority (75%) had correctly identified what each colour-coded bead represents in the CycleBeads ®, and an aggregate of 90.5% of women practised all the elements of correct use. This study demonstrates the importance of the SDM in increasing the availability and accessibility of family planning, and the potential to improve family planning method choice and method mix by expanding use of the SDM.

  17. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  18. Standard Test Methods for Constituent Content of Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods determine the constituent content of composite materials by one of two approaches. Method I physically removes the matrix by digestion or ignition by one of seven procedures, leaving the reinforcement essentially unaffected and thus allowing calculation of reinforcement or matrix content (by weight or volume) as well as percent void volume. Method II, applicable only to laminate materials of known fiber areal weight, calculates reinforcement or matrix content (by weight or volume), and the cured ply thickness, based on the measured thickness of the laminate. Method II is not applicable to the measurement of void volume. 1.1.1 These test methods are primarily intended for two-part composite material systems. However, special provisions can be made to extend these test methods to filled material systems with more than two constituents, though not all test results can be determined in every case. 1.1.2 The procedures contained within have been designed to be particularly effective for ce...

  19. A method for developing standard patient education program

    DEFF Research Database (Denmark)

    Lura, Carolina Bryne; Hauch, Sophie Misser Pallesgaard; Gøeg, Kirstine Rosenbeck

    2018-01-01

    procedure by using videos for teaching as well as procedural support. A step-by-step guide was developed and used as basis for making the videos. Quality assurance through evaluation with a nurse was conducted on both the step-by-step guide and the videos. The quality assurance evaluation of the videos...... for developing standard digital patient education programs for patients in self-administration of blood samples drawn from CVC. The Design Science Research Paradigm was used to develop a digital patient education program, called PAVIOSY, to increase patient safety during execution of the blood sample collection...... of the educational patient system, health professionals must be engaged early in the development of content and design phase....

  20. Standard guide for three methods of assessing buried steel tanks

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This guide covers procedures to be implemented prior to the application of cathodic protection for evaluating the suitability of a tank for upgrading by cathodic protection alone. 1.2 Three procedures are described and identified as Methods A, B, and C. 1.2.1 Method A—Noninvasive with primary emphasis on statistical and electrochemical analysis of external site environment corrosion data. 1.2.2 Method B—Invasive ultrasonic thickness testing with external corrosion evaluation. 1.2.3 Method C—Invasive permanently recorded visual inspection and evaluation including external corrosion assessment. 1.3 This guide presents the methodology and the procedures utilizing site and tank specific data for determining a tank's condition and the suitability for such tanks to be upgraded with cathodic protection. 1.4 The tank's condition shall be assessed using Method A, B, or C. Prior to assessing the tank, a preliminary site survey shall be performed pursuant to Section 8 and the tank shall be tightness test...

  1. Standard method of test for radioactive cesium in water

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Concentrations of radioactive Cs greater than 1 μCi/l in water were determined by gamma counting after separation by extraction. The method is limited to 134 Cs, 136 Cs, 137 Cs, and 138 Cs. The radioactive Cs is extracted at pH 7.0 as cesium tetraphenylborate in amyl acetate with EDTA present to prevent the extraction of undesirable fission products. The γ activity of a sample of the organic phase is determined by γ spectroscopy. Large amounts of Na + , K + , Cs + , Rb + , NH 4 + , Ag + , and free acid interfere with the separation process in the procedure. The overall precision of the method is +-5 percent

  2. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  3. Standard methods for research on apis mellifera gut symbionts

    Science.gov (United States)

    Gut microbes can play an important role in digestion, disease resistance, and the general health of animals, but little is known about the biology of gut symbionts in Apis mellifera. This paper is part of a series on honey bee research methods, providing protocols for studying gut symbionts. We desc...

  4. Standard methods for research on Apis mellifera gut symbionts

    Science.gov (United States)

    Gut microbes can play an important role in digestion, disease resistance, and the general health of animals, but little is known about the biology of gut symbionts in Apis mellifera. This paper is part of a series on honey bee research methods, providing protocols for studying gut symbionts. We desc...

  5. Application of new standardization method in activation analysis with registration of soft gamma radiation

    International Nuclear Information System (INIS)

    Vo Dac Bang; Phan Thu Huong.

    1983-01-01

    An application of the new standardization method for rapid activation mass analysis with the registration of the strongly absorbed low-energy gamma radiation is described. This method makes it possible to avoid the Use of the time-consumina and laboriuous method of Internal Standard

  6. Electron microscopy of flatworms standard and cryo-preparation methods.

    Science.gov (United States)

    Salvenmoser, Willi; Egger, Bernhard; Achatz, Johannes G; Ladurner, Peter; Hess, Michael W

    2010-01-01

    Electron microscopy (EM) has long been indispensable for flatworm research, as most of these worms are microscopic in dimension and provide only a handful of characters recognizable by eye or light microscopy. Therefore, major progress in understanding the histology, systematics, and evolution of this animal group relied on methods capable of visualizing ultrastructure. The rise of molecular and cellular biology renewed interest in such ultrastructural research. In the light of recent developments, we offer a best-practice guide for users of transmission EM and provide a comparison of well-established chemical fixation protocols with cryo-processing methods (high-pressure freezing/freeze-substitution, HPF/FS). The organisms used in this study include the rhabditophorans Macrostomum lignano, Polycelis nigra and Dugesia gonocephala, as well as the acoel species Isodiametra pulchra. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Standard Test Methods for Determining Mechanical Integrity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedures for determining the ability of photovoltaic modules to withstand the mechanical loads, stresses and deflections used to simulate, on an accelerated basis, high wind conditions, heavy snow and ice accumulation, and non-planar installation effects. 1.1.1 A static load test to 2400 Pa is used to simulate wind loads on both module surfaces 1.1.2 A static load test to 5400 Pa is used to simulate heavy snow and ice accumulation on the module front surface. 1.1.3 A twist test is used to simulate the non-planar mounting of a photovoltaic module by subjecting it to a twist angle of 1.2°. 1.1.4 A cyclic load test of 10 000 cycles duration and peak loading to 1440 Pa is used to simulate dynamic wind or other flexural loading. Such loading might occur during shipment or after installation at a particular location. 1.2 These test methods define photovoltaic test specimens and mounting methods, and specify parameters that must be recorded and reported. 1.3 Any individual mech...

  8. Positron emission mammography (PEM): reviewing standardized semiquantitative method.

    Science.gov (United States)

    Yamamoto, Yayoi; Tasaki, Youichiro; Kuwada, Yukiko; Ozawa, Yukihiko; Katayama, Atsushi; Kanemaki, Yoshihide; Enokido, Katsutoshi; Nakamura, Seigo; Kubouchi, Kouichi; Morita, Satoshi; Noritake, Mutsumi; Nakajima, Yasuo; Inoue, Tomio

    2013-11-01

    To validate semiquantitative analysis of positron emission mammography (PEM). Fifty women with histologically confirmed breast lesions were retrospectively enrolled. Semiquantitative uptake values (4 methods), the maximum PEM uptake value (PUVmax), and the lesion-to-background (LTB) value (3 methods) were measured. LTB is a ratio of the lesion's PUVmax to the mean background; LTB1, LTB2, and LTB3 (which were calculated on different background) were used to designate the three values measured. Interobserver reliability between two readers for PUVmax and the LTBs was tested using the interobserver correlation coefficient (ICC). The likelihood ratio test was used to evaluate the relationship between ICCs. Receiver operating characteristic (ROC) curves were calculated for all methods. Diagnostic accuracy in differentiating benign tissue from malignant tissue was compared between PUVmax and LTB1. The ICC rate was 0.971 [95 % confidence interval (CI) 0.943-0.986] for PUVmax, 0.873 (95 % CI 0.758-0.935) for LTB1, 0.965 (95 % CI 0.925-0.983) for LTB2, and 0.895 (95 % CI 0.799-0.946) for LTB3. However, there were some technical difficulties in the practical use of LTB2 and LTB3. The likelihood ratio test between PUVmax and LTB1 was statistically significant (p PEM in semiquantitative analysis.

  9. TL glow ratios at different temperature intervals of integration in thermoluminescence method. Comparison of Japanese standard (MHLW notified) method with CEN standard methods

    International Nuclear Information System (INIS)

    Todoriki, Setsuko; Saito, Kimie; Tsujimoto, Yuka

    2008-01-01

    The effect of the integration temperature intervals of TL intensities on the TL glow ratio was examined in comparison of the notified method of the Ministry of Health, Labour and Welfare (MHLW method) with EN1788. Two kinds of un-irradiated geological standard rock and three kinds of spices (black pepper, turmeric, and oregano) irradiated at 0.3 kGy or 1.0 kGy were subjected to TL analysis. Although the TL glow ratio exceeded 0.1 in the andesite according to the calculation of the MHLW notified method (integration interval; 70-490degC), the maximum of the first glow were observed at 300degC or more, attributed the influence of the natural radioactivity and distinguished from food irradiation. When the integration interval was set to 166-227degC according to EN1788, the TL glow ratios became remarkably smaller than 0.1, and the evaluation of the un-irradiated sample became more clear. For spices, the TL glow ratios by the MHLW notified method fell below 0.1 in un-irradiated samples and exceeded 0.1 in irradiated ones. Moreover, Glow1 maximum temperatures of the irradiated samples were observed at the range of 168-196degC, and those of un-irradiated samples were 258degC or more. Therefore, all samples were correctly judged by the criteria of the MHLW method. However, based on the temperature range of integration defined by EN1788, the TL glow ratio of un-irradiated samples remarkably became small compared with that of the MHLW method, and the discrimination of the irradiated sample from non-irradiation sample became clearer. (author)

  10. Business transactions and standards. Towards a system of concepts and a method for early problem identification in standard implementation projects

    NARCIS (Netherlands)

    Rukanova, B.D.

    2005-01-01

    To summarize, with respect to research question one we constructed a system of concepts, while in answer to research question two we proposed a method of how to apply this system of concepts in practice in order to identify potential problems in early stages of standard implementation projects.

  11. An overview of failure assessment methods in codes and standards

    International Nuclear Information System (INIS)

    Zerbst, U.; Ainsworth, R.A.

    2003-01-01

    This volume provides comprehensive up-to-date information on the assessment of the integrity of engineering structures containing crack-like flaws, in the absence of effects of creep at elevated temperatures (see volume 5) and of environment (see volume 6). Key methods are extensively reviewed and background information as well as validation is given. However, it should be kept in mind that for actual detailed assessments the relevant documents have to be consulted. In classical engineering design, an applied stress is compared with the appropriate material resistance expressed in terms of a limit stress, such as the yield strength or fatigue endurance limit. As long as the material resistance exceeds the applied stress, integrity of the component is assured. It is implicitly assumed that the component is defect-free but design margins provide some protection against defects. Modern design and operation philosophies, however, take explicit account of the possible presence of defects in engineering components. Such defects may arise from fabrication, e.g., during casting, welding, or forming processes, or may develop during operation. They may extend during operation and eventually lead to failure, which in the ideal case occurs beyond the design life of the component. Failure assessment methods are based upon the behavior of sharp cracks in structures, and for this reason all flaws or defects found in structures have to be treated as if they are sharp planar cracks. Hence the terms flaw or defect should be regarded as being interchangeable with the term crack throughout this volume. (orig.)

  12. Mitochondrial structure and function are disrupted by standard isolation methods.

    Directory of Open Access Journals (Sweden)

    Martin Picard

    Full Text Available Mitochondria regulate critical components of cellular function via ATP production, reactive oxygen species production, Ca(2+ handling and apoptotic signaling. Two classical methods exist to study mitochondrial function of skeletal muscles: isolated mitochondria and permeabilized myofibers. Whereas mitochondrial isolation removes a portion of the mitochondria from their cellular environment, myofiber permeabilization preserves mitochondrial morphology and functional interactions with other intracellular components. Despite this, isolated mitochondria remain the most commonly used method to infer in vivo mitochondrial function. In this study, we directly compared measures of several key aspects of mitochondrial function in both isolated mitochondria and permeabilized myofibers of rat gastrocnemius muscle. Here we show that mitochondrial isolation i induced fragmented organelle morphology; ii dramatically sensitized the permeability transition pore sensitivity to a Ca(2+ challenge; iii differentially altered mitochondrial respiration depending upon the respiratory conditions; and iv dramatically increased H(2O(2 production. These alterations are qualitatively similar to the changes in mitochondrial structure and function observed in vivo after cellular stress-induced mitochondrial fragmentation, but are generally of much greater magnitude. Furthermore, mitochondrial isolation markedly altered electron transport chain protein stoichiometry. Collectively, our results demonstrate that isolated mitochondria possess functional characteristics that differ fundamentally from those of intact mitochondria in permeabilized myofibers. Our work and that of others underscores the importance of studying mitochondrial function in tissue preparations where mitochondrial structure is preserved and all mitochondria are represented.

  13. Standardized method for reproducing the sequential X-rays flap

    International Nuclear Information System (INIS)

    Brenes, Alejandra; Molina, Katherine; Gudino, Sylvia

    2009-01-01

    A method is validated to estandardize in the taking, developing and analysis of bite-wing radiographs taken in sequential way, in order to compare and evaluate detectable changes in the evolution of the interproximal lesions through time. A radiographic positioner called XCP® is modified by means of a rigid acrylic guide, to achieve proper of the X ray equipment core positioning relative to the XCP® ring and the reorientation during the sequential x-rays process. 16 subjects of 4 to 40 years old are studied for a total number of 32 registries. Two x-rays of the same block of teeth of each subject have been taken in sequential way, with a minimal difference of 30 minutes between each one, before the placement of radiographic attachment. The images have been digitized with a Super Cam® scanner and imported to a software. The measurements in X and Y-axis for both x-rays were performed to proceed to compare. The intraclass correlation index (ICI) has shown that the proposed method is statistically related to measurement (mm) obtained in the X and Y-axis for both sequential series of x-rays (p=0.01). The measures of central tendency and dispersion have shown that the usual occurrence is indifferent between the two measurements (Mode 0.000 and S = 0083 and 0.109) and that the probability of occurrence of different values is lower than expected. (author) [es

  14. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  15. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  16. Standard methods for sampling and sample preparation for gamma spectroscopy

    International Nuclear Information System (INIS)

    Taskaeva, M.; Taskaev, E.; Nikolov, P.

    1993-01-01

    The strategy for sampling and sample preparation is outlined: necessary number of samples; analysis and treatment of the results received; quantity of the analysed material according to the radionuclide concentrations and analytical methods; the minimal quantity and kind of the data needed for making final conclusions and decisions on the base of the results received. This strategy was tested in gamma spectroscopic analysis of radionuclide contamination of the region of Eleshnitsa Uranium Mines. The water samples was taken and stored according to the ASTM D 3370-82. The general sampling procedures were in conformity with the recommendations of ISO 5667. The radionuclides was concentrated by coprecipitation with iron hydroxide and ion exchange. The sampling of soil samples complied with the rules of ASTM C 998, and their sample preparation - with ASTM C 999. After preparation the samples were sealed hermetically and measured. (author)

  17. A collaborative comparison of objective structured clinical examination (OSCE) standard setting methods at Australian medical schools

    NARCIS (Netherlands)

    Malau-Aduli, B.S.; Teague, P.A.; D'Souza, K.; Heal, C.; Turner, R.; Garne, D.L.; Vleuten, C. van der

    2017-01-01

    BACKGROUND: A key issue underpinning the usefulness of the OSCE assessment to medical education is standard setting, but the majority of standard-setting methods remain challenging for performance assessment because they produce varying passing marks. Several studies have compared standard-setting

  18. Retinoblastoma: Achieving new standards with methods of chemotherapy

    Directory of Open Access Journals (Sweden)

    Swathi Kaliki

    2015-01-01

    Full Text Available The management of retinoblastoma (RB has dramatically changed over the past two decades from previous radiotherapy methods to current chemotherapy strategies. RB is a remarkably chemotherapy-sensitive tumor. Chemotherapy is currently used as a first-line approach for children with this malignancy and can be delivered by intravenous, intra-arterial, periocular, and intravitreal routes. The choice of route for chemotherapy administration depends upon the tumor laterality and tumor staging. Intravenous chemotherapy (IVC is used most often in bilateral cases, orbital RB, and as an adjuvant treatment in high-risk RB. Intra-arterial chemotherapy (IAC is used in cases with group C or D RB and selected cases of group E tumor. Periocular chemotherapy is used as an adjunct treatment in eyes with group D and E RB and those with persistent/recurrent vitreous seeds. Intravitreal chemotherapy is reserved for eyes with persistent/recurrent vitreous seeds. In this review, we describe the various forms of chemotherapy used in the management of RB. A database search was performed on PubMed, using the terms "RB," and "treatment," "chemotherapy," "systemic chemotherapy," "IVC," "IAC," "periocular chemotherapy," or "intravitreal chemotherapy." Relevant English language articles were extracted, reviewed, and referenced appropriately.

  19. Retinoblastoma: Achieving new standards with methods of chemotherapy

    Science.gov (United States)

    Kaliki, Swathi; Shields, Carol L

    2015-01-01

    The management of retinoblastoma (RB) has dramatically changed over the past two decades from previous radiotherapy methods to current chemotherapy strategies. RB is a remarkably chemotherapy-sensitive tumor. Chemotherapy is currently used as a first-line approach for children with this malignancy and can be delivered by intravenous, intra-arterial, periocular, and intravitreal routes. The choice of route for chemotherapy administration depends upon the tumor laterality and tumor staging. Intravenous chemotherapy (IVC) is used most often in bilateral cases, orbital RB, and as an adjuvant treatment in high-risk RB. Intra-arterial chemotherapy (IAC) is used in cases with group C or D RB and selected cases of group E tumor. Periocular chemotherapy is used as an adjunct treatment in eyes with group D and E RB and those with persistent/recurrent vitreous seeds. Intravitreal chemotherapy is reserved for eyes with persistent/recurrent vitreous seeds. In this review, we describe the various forms of chemotherapy used in the management of RB. A database search was performed on PubMed, using the terms “RB,” and “treatment,” “chemotherapy,” “systemic chemotherapy,” “IVC,” “IAC,” “periocular chemotherapy,” or “intravitreal chemotherapy.” Relevant English language articles were extracted, reviewed, and referenced appropriately. PMID:25827539

  20. Standard test methods for bend testing of material for ductility

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover bend testing for ductility of materials. Included in the procedures are four conditions of constraint on the bent portion of the specimen; a guided-bend test using a mandrel or plunger of defined dimensions to force the mid-length of the specimen between two supports separated by a defined space; a semi-guided bend test in which the specimen is bent, while in contact with a mandrel, through a specified angle or to a specified inside radius (r) of curvature, measured while under the bending force; a free-bend test in which the ends of the specimen are brought toward each other, but in which no transverse force is applied to the bend itself and there is no contact of the concave inside surface of the bend with other material; a bend and flatten test, in which a transverse force is applied to the bend such that the legs make contact with each other over the length of the specimen. 1.2 After bending, the convex surface of the bend is examined for evidence of a crack or surface irregu...

  1. Standard setting in student assessment: is a defensible method yet to come?

    Science.gov (United States)

    Barman, A

    2008-11-01

    Setting, maintaining and re-evaluation of assessment standard periodically are important issues in medical education. The cut-off scores are often "pulled from the air" or set to an arbitrary percentage. A large number of methods/procedures used to set standard or cut score are described in literature. There is a high degree of uncertainty in performance standard set by using these methods. Standards set using the existing methods reflect the subjective judgment of the standard setters. This review is not to describe the existing standard setting methods/procedures but to narrate the validity, reliability, feasibility and legal issues relating to standard setting. This review is on some of the issues in standard setting based on the published articles of educational assessment researchers. Standard or cut-off score should be to determine whether the examinee attained the requirement to be certified competent. There is no perfect method to determine cut score on a test and none is agreed upon as the best method. Setting standard is not an exact science. Legitimacy of the standard is supported when performance standard is linked to the requirement of practice. Test-curriculum alignment and content validity are important for most educational test validity arguments. Representative percentage of must-know learning objectives in the curriculum may be the basis of test items and pass/fail marks. Practice analysis may help in identifying the must-know areas of curriculum. Cut score set by this procedure may give the credibility, validity, defensibility and comparability of the standard. Constructing the test items by subject experts and vetted by multi-disciplinary faculty members may ensure the reliability of the test as well as the standard.

  2. 42 CFR 440.260 - Methods and standards to assure quality of services.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Methods and standards to assure quality of services. 440.260 Section 440.260 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH... and Limits Applicable to All Services § 440.260 Methods and standards to assure quality of services...

  3. Validation of the Standard Method for Assessing Flicker From Wind Turbines

    DEFF Research Database (Denmark)

    Barahona Garzon, Braulio; Sørensen, Poul Ejnar; Christensen, L.

    2011-01-01

    This paper studies the validity of the standard method in IEC 61400-21 for assessing the flicker emission from multiple wind turbines. The standard method is based on testing a single wind turbine and then using the results of this test to assess the flicker emission from a number of wind turbines...... the flicker emission at the collection line; this assessment is then compared to the actual measurements in order to study the accuracy of the estimation. It was observed in both wind farms, that the assessment based on the standard method is statistically conservative compared to the measurements. The reason...... for this is the statistical characteristics of flicker emission....

  4. A collaborative comparison of objective structured clinical examination (OSCE) standard setting methods at Australian medical schools.

    Science.gov (United States)

    Malau-Aduli, Bunmi Sherifat; Teague, Peta-Ann; D'Souza, Karen; Heal, Clare; Turner, Richard; Garne, David L; van der Vleuten, Cees

    2017-12-01

    A key issue underpinning the usefulness of the OSCE assessment to medical education is standard setting, but the majority of standard-setting methods remain challenging for performance assessment because they produce varying passing marks. Several studies have compared standard-setting methods; however, most of these studies are limited by their experimental scope, or use data on examinee performance at a single OSCE station or from a single medical school. This collaborative study between 10 Australian medical schools investigated the effect of standard-setting methods on OSCE cut scores and failure rates. This research used 5256 examinee scores from seven shared OSCE stations to calculate cut scores and failure rates using two different compromise standard-setting methods, namely the Borderline Regression and Cohen's methods. The results of this study indicate that Cohen's method yields similar outcomes to the Borderline Regression method, particularly for large examinee cohort sizes. However, with lower examinee numbers on a station, the Borderline Regression method resulted in higher cut scores and larger difference margins in the failure rates. Cohen's method yields similar outcomes as the Borderline Regression method and its application for benchmarking purposes and in resource-limited settings is justifiable, particularly with large examinee numbers.

  5. 40 CFR 1043.50 - Approval of methods to meet Tier 1 retrofit NOX standards.

    Science.gov (United States)

    2010-07-01

    ... retrofit NOX standards. 1043.50 Section 1043.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF NOX, SOX, AND PM EMISSIONS FROM MARINE ENGINES AND VESSELS SUBJECT TO THE MARPOL PROTOCOL § 1043.50 Approval of methods to meet Tier 1 retrofit NOX standards...

  6. Developing content standards for teaching research skills using a delphi method

    NARCIS (Netherlands)

    Schaaf, M.F. van der; Stokking, K.M.; Verloop, N.

    2005-01-01

    The increased attention for teacher assessment and current educational reforms ask for procedures to develop adequate content standards. For the development of content standards on teaching research skills, a Delphi method based on stakeholders’ judgments has been designed and tested. In three

  7. Analysis of a non-standard mixed finite element method with applications to superconvergence

    NARCIS (Netherlands)

    Brandts, J.H.

    2009-01-01

    We show that a non-standard mixed finite element method proposed by Barrios and Gatica in 2007, is a higher order perturbation of the least-squares mixed finite element method. Therefore, it is also superconvergent whenever the least-squares mixed finite element method is superconvergent.

  8. Combining the Best of Two Standard Setting Methods: The Ordered Item Booklet Angoff

    Science.gov (United States)

    Smith, Russell W.; Davis-Becker, Susan L.; O'Leary, Lisa S.

    2014-01-01

    This article describes a hybrid standard setting method that combines characteristics of the Angoff (1971) and Bookmark (Mitzel, Lewis, Patz & Green, 2001) methods. The proposed approach utilizes strengths of each method while addressing weaknesses. An ordered item booklet, with items sorted based on item difficulty, is used in combination…

  9. Analysis and Comparison of Thickness and Bending Measurements from Fabric Touch Tester (FTT and Standard Methods

    Directory of Open Access Journals (Sweden)

    Musa Atiyyah Binti Haji

    2018-03-01

    Full Text Available Fabric Touch Tester (FTT is a relatively new device from SDL Atlas to determine touch properties of fabrics. It simultaneously measures 13 touch-related fabric physical properties in four modules that include bending and thickness measurements. This study aims to comparatively analyze the thickness and bending measurements made by the FTT and the common standard methods used in the textile industry. The results obtained with the FTT for 11 different fabrics were compared with that of standard methods. Despite the different measurement principle, a good correlation was found between the two methods used for the assessment of thickness and bending. As FTT is a new tool for textile comfort measurement and no standard yet exists, these findings are essential to determine the reliability of the measurements and how they relate to the well-established standard methods.

  10. Standard test method for radiochemical determination of uranium isotopes in urine by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the determination of uranium in urine at levels of detection dependent on sample size, count time, detector background, and tracer yield. It is designed as a screening tool for detection of possible exposure of occupational workers. 1.2 This test method is designed for 50 mL of urine. This test method does not address the sampling protocol or sample preservation methods associated with its use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    Science.gov (United States)

    Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...

  12. A Standardized Method for 4D Ultrasound-Guided Peripheral Nerve Blockade and Catheter Placement

    Directory of Open Access Journals (Sweden)

    N. J. Clendenen

    2014-01-01

    Full Text Available We present a standardized method for using four-dimensional ultrasound (4D US guidance for peripheral nerve blocks. 4D US allows for needle tracking in multiple planes simultaneously and accurate measurement of the local anesthetic volume surrounding the nerve following injection. Additionally, the morphology and proximity of local anesthetic spread around the target nerve is clearly seen with the described technique. This method provides additional spatial information in real time compared to standard two-dimensional ultrasound.

  13. Standard Test Method for Measuring Heat Flux Using a Water-Cooled Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of a steady heat flux to a given water-cooled surface by means of a system energy balance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Standard test method for uranium analysis in natural and waste water by X-ray fluorescence

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method applies for the determination of trace uranium content in waste water. It covers concentrations of U between 0.05 mg/L and 2 mg/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. [Preparation of sub-standard samples and XRF analytical method of powder non-metallic minerals].

    Science.gov (United States)

    Kong, Qin; Chen, Lei; Wang, Ling

    2012-05-01

    In order to solve the problem that standard samples of non-metallic minerals are not satisfactory in practical work by X-ray fluorescence spectrometer (XRF) analysis with pressed powder pellet, a method was studied how to make sub-standard samples according to standard samples of non-metallic minerals and to determine how they can adapt to analysis of mineral powder samples, taking the K-feldspar ore in Ebian-Wudu, Sichuan as an example. Based on the characteristic analysis of K-feldspar ore and the standard samples by X-ray diffraction (XRD) and chemical methods, combined with the principle of the same or similar between the sub-standard samples and unknown samples, the experiment developed the method of preparation of sub-standard samples: both of the two samples above mentioned should have the same kind of minerals and the similar chemical components, adapt mineral processing, and benefit making working curve. Under the optimum experimental conditions, a method for determination of SiO2, Al2O3, Fe2O3, TiO2, CaO, MgO, K2O and Na2O of K-feldspar ore by XRF was established. Thedetermination results are in good agreement with classical chemical methods, which indicates that this method was accurate.

  16. Standard test method for linear thermal expansion of glaze frits and ceramic whiteware materials by the interferometric method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers the interferometric determination of linear thermal expansion of premelted glaze frits and fired ceramic whiteware materials at temperatures lower than 1000°C (1830°F). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Validation of uncertainty of weighing in the preparation of radionuclide standards by Monte Carlo Method

    International Nuclear Information System (INIS)

    Cacais, F.L.; Delgado, J.U.; Loayza, V.M.

    2016-01-01

    In preparing solutions for the production of radionuclide metrology standards is necessary measuring the quantity Activity by mass. The gravimetric method by elimination is applied to perform weighing with smaller uncertainties. At this work is carried out the validation, by the Monte Carlo method, of the uncertainty calculation approach implemented by Lourenco and Bobin according to ISO GUM for the method by elimination. The results obtained by both uncertainty calculation methods were consistent indicating that were fulfilled the conditions for the application of ISO GUM in the preparation of radioactive standards. (author)

  18. The Standardization Method of Address Information for POIs from Internet Based on Positional Relation

    Directory of Open Access Journals (Sweden)

    WANG Yong

    2016-05-01

    Full Text Available As points of interest (POIon the internet, exists widely incomplete addresses and inconsistent literal expressions, a fast standardization processing method of network POIs address information based on spatial constraints was proposed. Based on the model of the extensible address expression, first of all, address information of POI was segmented and extracted. Address elements are updated by means of matching with the address tree layer by layer. Then, by defining four types of positional relations, corresponding set are selected from standard POI library as candidate for enrichment and amendment of non-standard address. At last, the fast standardized processing of POI address information was achieved with the help of backtracking address elements with minimum granularity. Experiments in this paper proved that the standardization processing of an address can be realized by means of this method with higher accuracy in order to build the address database.

  19. Standard Test Method for Gel Time of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of gel time of carbon fiber-epoxy tape and sheet. The test method is suitable for the measurement of gel time of resin systems having either high or low viscosity. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Standard test methods for conducting time-for-rupture notch tension tests of materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover the determination of the time for rupture of notched specimens under conditions of constant load and temperature. These test methods also includes the essential requirements for testing equipment. 1.2 The values stated in inch-pound units are to be regarded as the standard. The units in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. The standard deviation method: data analysis by classical means and by neural networks

    International Nuclear Information System (INIS)

    Bugmann, G.; Stockar, U. von; Lister, J.B.

    1989-08-01

    The Standard Deviation Method is a method for determining particle size which can be used, for instance, to determine air-bubble sizes in a fermentation bio-reactor. The transmission coefficient of an ultrasound beam through a gassy liquid is measured repetitively. Due to the displacements and random positions of the bubbles, the measurements show a scatter whose standard deviation is dependent on the bubble-size. The precise relationship between the measured standard deviation, the transmission and the particle size has been obtained from a set of computer-simulated data. (author) 9 figs., 5 refs

  2. Color Standardization Method and System for Whole Slide Imaging Based on Spectral Sensing

    Directory of Open Access Journals (Sweden)

    Shinsuke Tani

    2012-01-01

    Full Text Available In the field of whole slide imaging, the imaging device or staining process cause color variations for each slide that affect the result of image analysis made by pathologist. In order to stabilize the analysis, we developed a color standardization method and system as described below: 1 Color standardization method based on RGB imaging and multi spectral sensing, which utilize less band (16 bands than conventional method (60 bands, 2 High speed spectral sensing module. As a result, we confirmed the following effect: 1 We confirmed the performance improvement of nucleus detection by the color standardization. And we can conduct without training data set which is needed in conventional method, 2 We can get detection performance of H&E component equivalent to conventional method (60 bands. And measurement process is more than 255 times faster.

  3. A standardized method for sampling and extraction methods for quantifying microplastics in beach sand.

    Science.gov (United States)

    Besley, Aiken; Vijver, Martina G; Behrens, Paul; Bosker, Thijs

    2017-01-15

    Microplastics are ubiquitous in the environment, are frequently ingested by organisms, and may potentially cause harm. A range of studies have found significant levels of microplastics in beach sand. However, there is a considerable amount of methodological variability among these studies. Methodological variation currently limits comparisons as there is no standard procedure for sampling or extraction of microplastics. We identify key sampling and extraction procedures across the literature through a detailed review. We find that sampling depth, sampling location, number of repeat extractions, and settling times are the critical parameters of variation. Next, using a case-study we determine whether and to what extent these differences impact study outcomes. By investigating the common practices identified in the literature with the case-study, we provide a standard operating procedure for sampling and extracting microplastics from beach sand. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Improvement of precision method of spectrophotometry with inner standardization and its use in plutonium solutions analysis

    International Nuclear Information System (INIS)

    Stepanov, A.V.; Stepanov, D.A.; Nikitina, S.A.; Gogoleva, T.D.; Grigor'eva, M.G.; Bulyanitsa, L.S.; Panteleev, Yu.A.; Pevtsova, E.V.; Domkin, V.D.; Pen'kin, M.V.

    2006-01-01

    Precision method of spectrophotometry with inner standardization is used for analysis of pure Pu solutions. Improvement of the spectrophotometer and spectrophotometric method of analysis is done to decrease accidental constituent of relative error of the method. Influence of U, Np impurities and corrosion products on systematic constituent of error of the method, and effect of fluoride-ion on completeness of Pu oxidation in sample preparation are studied [ru

  5. Standard Test Methods for Solar Energy Transmittance and Reflectance (Terrestrial) of Sheet Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 These test methods cover the measurement of solar energy transmittance and reflectance (terrestrial) of materials in sheet form. Method A, using a spectrophotometer, is applicable for both transmittance and reflectance and is the referee method. Method B is applicable only for measurement of transmittance using a pyranometer in an enclosure and the sun as the energy source. Specimens for Method A are limited in size by the geometry of the spectrophotometer while Method B requires a specimen 0.61 m2 (2 ft2). For the materials studied by the drafting task group, both test methods give essentially equivalent results. 1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. 24 CFR Appendix II to Subpart C of... - Development of Standards; Calculation Methods

    Science.gov (United States)

    2010-04-01

    ...; Calculation Methods II Appendix II to Subpart C of Part 51 Housing and Urban Development Office of the...; Calculation Methods I. Background Information Concerning the Standards (a) Thermal Radiation: (1) Introduction... radiation being emitted. The radiation can cause severe burn, injuries and even death to exposed persons...

  7. Addressing Next Generation Science Standards: A Method for Supporting Classroom Teachers

    Science.gov (United States)

    Pellien, Tamara; Rothenburger, Lisa

    2014-01-01

    The Next Generation Science Standards (NGSS) will define science education for the foreseeable future, yet many educators struggle to see the bridge between current practice and future practices. The inquiry-based methods used by Extension professionals (Kress, 2006) can serve as a guide for classroom educators. Described herein is a method of…

  8. Standard Error Estimation of 3PL IRT True Score Equating with an MCMC Method

    Science.gov (United States)

    Liu, Yuming; Schulz, E. Matthew; Yu, Lei

    2008-01-01

    A Markov chain Monte Carlo (MCMC) method and a bootstrap method were compared in the estimation of standard errors of item response theory (IRT) true score equating. Three test form relationships were examined: parallel, tau-equivalent, and congeneric. Data were simulated based on Reading Comprehension and Vocabulary tests of the Iowa Tests of…

  9. The development and standardization of testing methods for genetically modified organisms and their derived products.

    Science.gov (United States)

    Zhang, Dabing; Guo, Jinchao

    2011-07-01

    As the worldwide commercialization of genetically modified organisms (GMOs) increases and consumers concern the safety of GMOs, many countries and regions are issuing labeling regulations on GMOs and their products. Analytical methods and their standardization for GM ingredients in foods and feed are essential for the implementation of labeling regulations. To date, the GMO testing methods are mainly based on the inserted DNA sequences and newly produced proteins in GMOs. This paper presents an overview of GMO testing methods as well as their standardization. © 2011 Institute of Botany, Chinese Academy of Sciences.

  10. A Mapmark method of standard setting as implemented for the National Assessment Governing Board.

    Science.gov (United States)

    Schulz, E Matthew; Mitzel, Howard C

    2011-01-01

    This article describes a Mapmark standard setting procedure, developed under contract with the National Assessment Governing Board (NAGB). The procedure enhances the bookmark method with spatially representative item maps, holistic feedback, and an emphasis on independent judgment. A rationale for these enhancements, and the bookmark method, is presented, followed by a detailed description of the materials and procedures used in a meeting to set standards for the 2005 National Assessment of Educational Progress (NAEP) in Grade 12 mathematics. The use of difficulty-ordered content domains to provide holistic feedback is a particularly novel feature of the method. Process evaluation results comparing Mapmark to Anghoff-based methods previously used for NAEP standard setting are also presented.

  11. Bronchial histamine challenge. A combined interrupter-dosimeter method compared with a standard method

    DEFF Research Database (Denmark)

    Pavlovic, M; Holstein-Rathlou, N H; Madsen, F

    1985-01-01

    We compared the provocative concentration (PC) values obtained by two different methods of performing bronchial histamine challenge. One test was done on an APTA, an apparatus which allows simultaneous provocation with histamine and measurement of airway resistance (Rtot) by the interrupter method....... The second test was a conventional tidal breathing method, with measurement of the FEV1. There was a high correlation between the PC20-FEV1 and the PC30-, PC40- and PC50-Rtot values. The correlation coefficients were 0.85, 0.71 and 0.70 (P less than 0.05) respectively. We further tested the reproducibility...

  12. Standard Test Method for Measuring Optical Angular Deviation of Transparent Parts Using the Double-Exposure Method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the measurement of the optical angular deviation of a light ray imposed by flat transparent parts such as a commercial or military aircraft windshield, canopy or cabin window. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.2.1 Exceptions—The values given in parentheses are for information only. Also, print size is provided in inch-pound measurements. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Standardization of 32P activity determination method in soil-root cores for root distribution studies

    International Nuclear Information System (INIS)

    Sharma, R.B.; Ghildyal, B.P.

    1976-01-01

    The root distribution of wheat variety UP 301 was obtained by determining the 32 P activity in soil-root cores by two methods, viz., ignition and triacid digestion. Root distribution obtained by these two methods was compared with that by standard root core washing procedure. The percent error in root distribution as determined by triacid digestion method was within +- 2.1 to +- 9.0 as against +- 5.5 to +- 21.2 by ignition method. Thus triacid digestion method proved better over the ignition method. (author)

  14. Standard Test Method for Bird Impact Testing of Aerospace Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers conducting bird impact tests under a standard set of conditions by firing a packaged bird at a stationary transparency mounted in a support structure. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.

  15. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  16. Standard test method for measurement of web/roller friction characteristics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers the simulation of a roller/web transport tribosystem and the measurement of the static and kinetic coefficient of friction of the web/roller couple when sliding occurs between the two. The objective of this test method is to provide users with web/roller friction information that can be used for process control, design calculations, and for any other function where web/roller friction needs to be known. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Standard test method for pin-type bearing test of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1984-01-01

    1.1 This test method covers a pin-type bearing test of metallic materials to determine bearing yield strength and bearing strength. Note 1—The presence of incidental lubricants on the bearing surfaces may significantly lower the value of bearing yield strength obtained by this method. 1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Standard test method for the radiochemical determination of americium-241 in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This method covers the determination of americium–241 in soil by means of chemical separations and alpha spectrometry. It is designed to analyze up to ten grams of soil or other sample matrices that contain up to 30 mg of combined rare earths. This method allows the determination of americium–241 concentrations from ambient levels to applicable standards. The values stated in SI units are to be regarded as standard. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precaution statements, see Section 10.

  19. Standard Test Method for Bond Strength of Ceramic Tile to Portland Cement Paste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the ability of glazed ceramic wall tile, ceramic mosaic tile, quarry tile, and pavers to be bonded to portland cement paste. This test method includes both face-mounted and back-mounted tile. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the measurement of heat transfer rate using a thermal capacitance-type calorimeter which assumes one-dimensional heat conduction into a cylindrical piece of material (slug) with known physical properties. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—For information see Test Methods E 285, E 422, E 458, E 459, and E 511.

  1. Standard setting of objective structured practical examination by modified Angoff method: A pilot study.

    Science.gov (United States)

    Kamath, M Ganesh; Pallath, Vinod; Ramnarayan, K; Kamath, Asha; Torke, Sharmila; Gonsalves, James

    2016-01-01

    The undergraduate curriculum at our institution is divided system-wise into four blocks, each block ending with theory and objective structured practical examination (OSPE). The OSPE in Physiology consists of 12 stations, and a conventional minimum score to qualify is 50%. We aimed to incorporate standard setting using the modified Angoff method in OSPE to differentiate the competent from the non-competent student and to explore the possibility of introducing standard setting in Physiology OSPE at our institution. Experts rated the OSPE using the modified Angoff method to obtain the standard set cut-off in two of the four blocks. We assessed the OSPE marks of 110 first year medical students. Chi-square test was used to compare the number of students who scored less than standard set cut-off and conventional cut-off; correlation coefficient was used to assess the relation between OSPE and theory marks in both blocks. Feedback was obtained from the experts. The standard set was 62% and 67% for blocks II and III, respectively. The use of standard set cut-off resulted in 16.3% (n=18) and 22.7% (n=25) students being declared unsuccessful in blocks II and III, respectively. Comparison between the number, who scored less than standard set and conventional cut-off was statistically significant (p=0.001). The correlation coefficient was 0.65 (p=0.003) and 0.52 (p<0.001) in blocks II and III, respectively. The experts welcomed the idea of standard setting. Standard setting helped in differentiating the competent from the non-competent student, indicating that standard setting enhances the quality of OSPE as an assessment tool.

  2. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Method of Fabricating NASA-Standard Macro-Fiber Composite Piezoelectric Actuators

    Science.gov (United States)

    High, James W.; Wilkie, W. Keats

    2003-01-01

    The NASA Macro-Fiber Composite actuator is a flexible piezoelectric composite device designed for controlling vibrations and shape deformations in high performance aerospace structures. A complete method for fabricating the standard NASA Macro-Fiber Composite actuator is presented in this document. When followed precisely, these procedures will yield devices with electromechanical properties identical to the standard actuator manufactured by NASA Langley Research Center.

  4. Standard Test Method for Resin Flow of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the amount of resin flow that will take place from prepreg tape or sheet under given conditions of temperature and pressure. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Implementation of sum-peak method for standardization of positron emission radionuclides

    International Nuclear Information System (INIS)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Mercia Liane de; Lima, Fernando Roberto de Andrade

    2015-01-01

    Positron Emission Tomography (PET) is being increasingly recognized as an important quantitative imaging tool for diagnosis and assessing response to therapy. As correct dose administration plays a crucial part in nuclear medicine, it is important that the instruments used to assay the activity of the short-lived radionuclides are calibrated accurately, with traceability to the national or international standards. The sum-peak method has been widely used for radionuclide standardization. The purpose of this study was to implement the methodology for standardization of PET radiopharmaceuticals at the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE). (author)

  6. Formative evaluation of ontology learning methods for entity discovery by using existing ontologies as reference standards.

    Science.gov (United States)

    Liu, K; Mitchell, K J; Chapman, W W; Savova, G K; Sioutos, N; Rubin, D L; Crowley, R S

    2013-01-01

    Developing a two-step method for formative evaluation of statistical Ontology Learning (OL) algorithms that leverages existing biomedical ontologies as reference standards. In the first step optimum parameters are established. A 'gap list' of entities is generated by finding the set of entities present in a later version of the ontology that are not present in an earlier version of the ontology. A named entity recognition system is used to identify entities in a corpus of biomedical documents that are present in the 'gap list', generating a reference standard. The output of the algorithm (new entity candidates), produced by statistical methods, is subsequently compared against this reference standard. An OL method that performs perfectly will be able to learn all of the terms in this reference standard. Using evaluation metrics and precision-recall curves for different thresholds and parameters, we compute the optimum parameters for each method. In the second step, human judges with expertise in ontology development evaluate each candidate suggested by the algorithm configured with the optimum parameters previously established. These judgments are used to compute two performance metrics developed from our previous work: Entity Suggestion Rate (ESR) and Entity Acceptance Rate (EAR). Using this method, we evaluated two statistical OL methods for OL in two medical domains. For the pathology domain, we obtained 49% ESR, 28% EAR with the Lin method and 52% ESR, 39% EAR with the Church method. For the radiology domain, we obtain 87% ESA, 9% EAR using Lin method and 96% ESR, 16% EAR using Church method. This method is sufficiently general and flexible enough to permit comparison of any OL method for a specific corpus and ontology of interest.

  7. Data Mining Methods Applied to Flight Operations Quality Assurance Data: A Comparison to Standard Statistical Methods

    Science.gov (United States)

    Stolzer, Alan J.; Halford, Carl

    2007-01-01

    In a previous study, multiple regression techniques were applied to Flight Operations Quality Assurance-derived data to develop parsimonious model(s) for fuel consumption on the Boeing 757 airplane. The present study examined several data mining algorithms, including neural networks, on the fuel consumption problem and compared them to the multiple regression results obtained earlier. Using regression methods, parsimonious models were obtained that explained approximately 85% of the variation in fuel flow. In general data mining methods were more effective in predicting fuel consumption. Classification and Regression Tree methods reported correlation coefficients of .91 to .92, and General Linear Models and Multilayer Perceptron neural networks reported correlation coefficients of about .99. These data mining models show great promise for use in further examining large FOQA databases for operational and safety improvements.

  8. Normalization method for metabolomics data using optimal selection of multiple internal standards

    Directory of Open Access Journals (Sweden)

    Yetukuri Laxman

    2007-03-01

    Full Text Available Abstract Background Success of metabolomics as the phenotyping platform largely depends on its ability to detect various sources of biological variability. Removal of platform-specific sources of variability such as systematic error is therefore one of the foremost priorities in data preprocessing. However, chemical diversity of molecular species included in typical metabolic profiling experiments leads to different responses to variations in experimental conditions, making normalization a very demanding task. Results With the aim to remove unwanted systematic variation, we present an approach that utilizes variability information from multiple internal standard compounds to find optimal normalization factor for each individual molecular species detected by metabolomics approach (NOMIS. We demonstrate the method on mouse liver lipidomic profiles using Ultra Performance Liquid Chromatography coupled to high resolution mass spectrometry, and compare its performance to two commonly utilized normalization methods: normalization by l2 norm and by retention time region specific standard compound profiles. The NOMIS method proved superior in its ability to reduce the effect of systematic error across the full spectrum of metabolite peaks. We also demonstrate that the method can be used to select best combinations of standard compounds for normalization. Conclusion Depending on experiment design and biological matrix, the NOMIS method is applicable either as a one-step normalization method or as a two-step method where the normalization parameters, influenced by variabilities of internal standard compounds and their correlation to metabolites, are first calculated from a study conducted in repeatability conditions. The method can also be used in analytical development of metabolomics methods by helping to select best combinations of standard compounds for a particular biological matrix and analytical platform.

  9. Standardization is superior to traditional methods of teaching open vascular simulation.

    Science.gov (United States)

    Bath, Jonathan; Lawrence, Peter; Chandra, Ankur; O'Connell, Jessica; Uijtdehaage, Sebastian; Jimenez, Juan Carlos; Davis, Gavin; Hiatt, Jonathan

    2011-01-01

    Standardizing surgical skills teaching has been proposed as a method to rapidly attain technical competence. This study compared acquisition of vascular skills by standardized vs traditional teaching methods. The study randomized 18 first-year surgical residents to a standardized or traditional group. Participants were taught technical aspects of vascular anastomosis using femoral anastomosis simulation (Limbs & Things, Savannah, Ga), supplemented with factual information. One expert instructor taught a standardized anastomosis technique using the same method each time to one group over four sessions, while, similar to current vascular training, four different expert instructors each taught one session to the other (traditional) group. Knowledge and technical skill were assessed at study completion by an independent vascular expert using Objective Structured Assessment of Technical Skill (OSATS) performance metrics. Participants also provided a written evaluation of the study experience. The standardized group had significantly higher mean overall technical (95.7% vs 75.8%; P = .038) and global skill scores (83.4% vs 67%; P = .006). Tissue handling, efficiency of motion, overall technical skill, and flow of operation were rated significantly higher in the standardized group (mean range, 88%-96% vs 67.6%-77.6%; P teaching methods on performance outcome. Findings from this report suggest that for simulation training, standardized may be more effective than traditional methods of teaching. Transferability of simulator-acquired skills to the clinical setting will be required before open simulation can be unequivocally recommended as a major component of resident technical skill training. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  10. Bronchial histamine challenge. A combined interrupter-dosimeter method compared with a standard method

    DEFF Research Database (Denmark)

    Pavlovic, M; Holstein-Rathlou, N H; Madsen, F

    1985-01-01

    We compared the provocative concentration (PC) values obtained by two different methods of performing bronchial histamine challenge. One test was done on an APTA, an apparatus which allows simultaneous provocation with histamine and measurement of airway resistance (Rtot) by the interrupter metho...

  11. Standard test method for determining residual stresses by the hole-drilling strain-gage method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 Residual Stress Determination: 1.1.1 This test method specifies a hole-drilling procedure for determining residual stress profiles near the surface of an isotropic linearly elastic material. The test method is applicable to residual stress profile determinations where in-plane stress gradients are small. The stresses may remain approximately constant with depth (“uniform” stresses) or they may vary significantly with depth (“non-uniform” stresses). The measured workpiece may be “thin” with thickness much less than the diameter of the drilled hole or “thick” with thickness much greater than the diameter of the drilled hole. Only uniform stress measurements are specified for thin workpieces, while both uniform and non-uniform stress measurements are specified for thick workpieces. 1.2 Stress Measurement Range: 1.2.1 The hole-drilling method can identify in-plane residual stresses near the measured surface of the workpiece material. The method gives localized measurements that indicate the...

  12. Standard Test Method for Electronic Measurement for Hydrogen Embrittlement From Cadmium-Electroplating Processes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers an electronic hydrogen detection instrument procedure for measurement of plating permeability to hydrogen. This method measures a variable related to hydrogen absorbed by steel during plating and to the hydrogen permeability of the plate during post plate baking. A specific application of this method is controlling cadmium-plating processes in which the plate porosity relative to hydrogen is critical, such as cadmium on high-strength steel. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement, see Section 8. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

  13. An external standard method for quantification of human cytomegalovirus by PCR

    International Nuclear Information System (INIS)

    Rongsen, Shen; Liren, Ma; Fengqi, Zhou; Qingliang, Luo

    1997-01-01

    An external standard method for PCR quantification of HCMV was reported. [α- 32 P]dATP was used as a tracer. 32 P-labelled specific amplification product was separated by agarose gel electrophoresis. A gel piece containing the specific product band was excised and counted in a plastic scintillation counter. Distribution of [α- 32 P]dATP in the electrophoretic gel plate and effect of separation between the 32 P-labelled specific product and free [α- 32 P]dATP were observed. A standard curve for quantification of HCMV by PCR was established and detective results of quality control templets were presented. The external standard method and the electrophoresis separation effect were appraised. The results showed that the method could be used for relative quantification of HCMV. (author)

  14. Standard test method for determination of surface lubrication on flexible webs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method has been used since 1988 as an ANSI/ISO standard test for determination of lubrication on processed photographic films. Its purpose was to determine the presence of process-surviving lubricants on photographic films. It is the purpose of this test method to expand the applicability of this test method to other flexible webs that may need lubrication for suitable performance. This test measures the breakaway (static) coefficient of friction of a metal rider on the web by the inclined plane method. The objectives of the test is to determine if a web surface has a lubricant present or not. It is not intended to assign a friction coefficient to a material. It is not intended to rank lubricants. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish ...

  15. Standard test methods for bend testing of metallic flat materials for spring applications involving static loading

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This standard describes three test methods for determining the modulus of elasticity in bending and the bending strength of metallic strips or sheets intended for the use in flat springs: 1.1.1 Test Method A—a cantilever beam, 1.1.2 Test Method B—a three-point loaded beam (that is, a beam resting on two supports and centrally loaded), and 1.1.3 Test Method C—a four-point loaded beam (that is, a beam resting on two supports and loaded at two points equally spaced from each support). 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 6.1 This test me...

  16. [Blood pressure measurement by primary care physicians: comparison with the standard method].

    Science.gov (United States)

    Asai, Y; Kawamoto, R; Nago, N; Kajii, E

    2000-04-01

    To examine the usual methods of blood pressure (BP) measurement by primary care physicians and to compare them with the standard methods. Cross-sectional survey by self-administered questionnaire. Primary care physicians who graduated from Jichi Medical School and were working at clinics. Each standard method for 20 items was defined as the one that was most frequently recommended by 6 guidelines (USA 3, UK 1, Canada 1, Japan 1) and a recent comprehensive review about BP measurement. Of 333 physicians, 190 (58%) responded (median age 33, range 26 to 45 years). Standard methods and percentages of physicians who follow them are: [BP measurement, 17 items] supported arm 96%; measurement to 2 mmHg 91%; sitting position 86%; mercury sphygmomanometer 83%; waiting > or = 1 minute between readings 58%; palpation to assess systolic BP before auscultation 57%; check accuracy of home BP monitor 56%; Korotkoff Phase V for diastolic BP 51%; bilateral measurements on initial visit 44%; small cuff available 41%; > or = 2 readings in patients with atrial fibrillation 38%; > or = 2 readings on one visit 20%; cuff deflation rate of 2 mmHg/pulse 14%; large cuff available 13%; check accuracy of monitor used for home visit 8%; waiting time > or = 5 minute 3%; readings from the arm with the higher BP 1%. [Knowledge about BP monitor, 2 items] appropriate size bladder: length 11%; width 11%. [Check of sphygmomanometer for leakage, inflate to 200 mmHg then close valve for 1 minute] leakage < 2 mmHg 6%; median 10 (range 0-200) mmHg. Average percentage of all 20 items was 39%. Number of methods physicians follow as standard: median 8 (range 4 to 15) and this number did not correlate with any background characteristics of the physicians. Furthermore, we also obtained information on methods not compared with the standard. Fifty-four percentage of physicians used more standard methods in deciding the start or change of treatment than in measuring BP of patients with good control. About 80% of

  17. Another Look at the Method of Y-Standardization in Logit and Probit Models

    DEFF Research Database (Denmark)

    Karlson, Kristian Bernt

    2015-01-01

    This paper takes another look at the derivation of the method of Y-standardization used in sociological analysis involving comparisons of coefficients across logit or probit models. It shows that the method can be derived under less restrictive assumptions than hitherto suggested. Rather than...... assuming that the logit or probit fixes the variance of the latent error at a known constant, it suffices to assume that the variance of the error is unknown. A further result suggests that using Y-standardization for cross-model comparisons is likely to be biased by model differences in the fit...

  18. Primary activity standardization of {sup 57}Co by sum-peak method

    Energy Technology Data Exchange (ETDEWEB)

    Iwahara, A. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)], E-mail: iwahara@ird.gov.br; Poledna, R.; Silva, C.J. da; Tauhata, L. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)

    2009-10-15

    The sum-peak method was applied to standardize a {sup 57}Co solution within the framework of an international comparison organized by International Atomic Energy Agency, in 2008, aimed toward international traceability of activity measurements. A planar germanium detector was used with the sources placed on top of the detector for activity determination measurements. An analytical expression for accidental summing correction was derived and the effect of the germanium characteristic KX-ray escape peak of 112 keV was taken into account. The standard uncertainty associated to the activity concentration value was 0.37% and the result was compared with other measurement methods.

  19. A standard curve based method for relative real time PCR data processing

    Directory of Open Access Journals (Sweden)

    Krause Andreas

    2005-03-01

    Full Text Available Abstract Background Currently real time PCR is the most precise method by which to measure gene expression. The method generates a large amount of raw numerical data and processing may notably influence final results. The data processing is based either on standard curves or on PCR efficiency assessment. At the moment, the PCR efficiency approach is preferred in relative PCR whilst the standard curve is often used for absolute PCR. However, there are no barriers to employ standard curves for relative PCR. This article provides an implementation of the standard curve method and discusses its advantages and limitations in relative real time PCR. Results We designed a procedure for data processing in relative real time PCR. The procedure completely avoids PCR efficiency assessment, minimizes operator involvement and provides a statistical assessment of intra-assay variation. The procedure includes the following steps. (I Noise is filtered from raw fluorescence readings by smoothing, baseline subtraction and amplitude normalization. (II The optimal threshold is selected automatically from regression parameters of the standard curve. (III Crossing points (CPs are derived directly from coordinates of points where the threshold line crosses fluorescence plots obtained after the noise filtering. (IV The means and their variances are calculated for CPs in PCR replicas. (V The final results are derived from the CPs' means. The CPs' variances are traced to results by the law of error propagation. A detailed description and analysis of this data processing is provided. The limitations associated with the use of parametric statistical methods and amplitude normalization are specifically analyzed and found fit to the routine laboratory practice. Different options are discussed for aggregation of data obtained from multiple reference genes. Conclusion A standard curve based procedure for PCR data processing has been compiled and validated. It illustrates that

  20. Standardization of size, shape and internal structure of spinal cord images: comparison of three transformation methods.

    Directory of Open Access Journals (Sweden)

    Yasuhisa Fujiki

    Full Text Available Functional fluorescence imaging has been widely applied to analyze spatio-temporal patterns of cellular dynamics in the brain and spinal cord. However, it is difficult to integrate spatial information obtained from imaging data in specific regions of interest across multiple samples, due to large variability in the size, shape and internal structure of samples. To solve this problem, we attempted to standardize transversely sectioned spinal cord images focusing on the laminar structure in the gray matter. We employed three standardization methods, the affine transformation (AT, the angle-dependent transformation (ADT and the combination of these two methods (AT+ADT. The ADT is a novel non-linear transformation method developed in this study to adjust an individual image onto the template image in the polar coordinate system. We next compared the accuracy of these three standardization methods. We evaluated two indices, i.e., the spatial distribution of pixels that are not categorized to any layer and the error ratio by the leave-one-out cross validation method. In this study, we used neuron-specific marker (NeuN-stained histological images of transversely sectioned cervical spinal cord slices (21 images obtained from 4 rats to create the standard atlas and also to serve for benchmark tests. We found that the AT+ADT outperformed other two methods, though the accuracy of each method varied depending on the layer. This novel image standardization technique would be applicable to optical recording such as voltage-sensitive dye imaging, and will enable statistical evaluations of neural activation across multiple samples.

  1. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  2. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  3. A simple web-based tool to compare freshwater fish data collected using AFS standard methods

    Science.gov (United States)

    Bonar, Scott A.; Mercado-Silva, Norman; Rahr, Matt; Torrey, Yuta T.; Cate, Averill

    2016-01-01

    The American Fisheries Society (AFS) recently published Standard Methods for Sampling North American Freshwater Fishes. Enlisting the expertise of 284 scientists from 107 organizations throughout Canada, Mexico, and the United States, this text was developed to facilitate comparisons of fish data across regions or time. Here we describe a user-friendly web tool that automates among-sample comparisons in individual fish condition, population length-frequency distributions, and catch per unit effort (CPUE) data collected using AFS standard methods. Currently, the web tool (1) provides instantaneous summaries of almost 4,000 data sets of condition, length frequency, and CPUE of common freshwater fishes collected using standard gears in 43 states and provinces; (2) is easily appended with new standardized field data to update subsequent queries and summaries; (3) compares fish data from a particular water body with continent, ecoregion, and state data summaries; and (4) provides additional information about AFS standard fish sampling including benefits, ongoing validation studies, and opportunities to comment on specific methods. The web tool—programmed in a PHP-based Drupal framework—was supported by several AFS Sections, agencies, and universities and is freely available from the AFS website and fisheriesstandardsampling.org. With widespread use, the online tool could become an important resource for fisheries biologists.

  4. [Establish quality evaluation method based on standard decoction of Danshen extract].

    Science.gov (United States)

    Dong, Qing; Yu, Hua-Tao; Dai, Yun-Tao; Chao, Jung; Fan, Zi-Quan; Wang, Dan-Dan; Zhu, Chao; Chen, Shi-Lin

    2017-03-01

    The quality of Danshen extract granules on market is largely different from each other mainly due to the heterogeneous quality of raw materials of Salvia miltiorrhiza, various producing procedures and lack of good quality evaluation method. Formula granule and "standard decoction" have the same quality. In this paper, a systematic evaluation method for the quality of Danshen decoction was established from the perspective of "standard decoction", in order to explore the main factors affecting the quality uniformity of Danshen extract granules. Danshen standard decoction was prepared; then the fingerprint method was developed to determine the content of salvianolic acid B; and the main peaks in the fingerprint were identified with UPLC-QTOF/MS to clarify the chemical compositions of Danshen decoction. Three indexes were calculated to evaluate the stability of whole process, including the extraction ratio; transfer rate of index components and pH value. The results showed that the main components of Danshen decoction were phenolic acids, while the extraction rate, the transfer rate of salvianolic acid B and pH value were in a relatively stable level, and the similarity in the fingerprint of standard decoction was high, indicating that the preparation procedure was stable. The level of salvianolic acid B in the standard decoction was in a large range, which was mainly due to the difference in the quality of Salviae Miltiorrhizae Radix et Rhizoma. Copyright© by the Chinese Pharmaceutical Association.

  5. THE COST MANAGEMENT BY APPLYING THE STANDARD COSTING METHOD IN THE FURNITURE INDUSTRY-Case study

    Directory of Open Access Journals (Sweden)

    Radu Mărginean

    2013-06-01

    Full Text Available Among the modern calculation methods used in managerial accounting, with a large applicability in the industrial production field, we can find the standard costing method. This managerial approach of cost calculation has a real value in the managerial accounting field, due to its usefulness in forecasting production costs, helping the managers in the decision making process. The standard costing method in managerial accounting is part of modern managerial accounting methods, used in many enterprises with production activity. As research objectives for this paper, we propose studying the possibility of implementing this modern method of cost calculation in a company from the Romanian furniture industry, using real financial data. In order to achieve this aim, we used some specialized literature in the field of managerial accounting, showing the strengths and weaknesses of this method. The case study demonstrates that the standard costing modern method of cost calculation has full applicability in our case, and in conclusion it has a real value in the cost management process for enterprises in the Romanian furniture industry.

  6. Determination of perfluorinated compounds in human plasma and serum standard reference materials using independent analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, Jessica L. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States); Phinney, Karen W. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); Keller, Jennifer M. [National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States)

    2011-11-15

    Perfluorinated compounds (PFCs) were measured in three National Institute of Standards and Technology (NIST) Standard Reference Materials (SRMs) (SRMs 1950 Metabolites in Human Plasma, SRM 1957 Organic Contaminants in Non-fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum) using two analytical approaches. The methods offer some independence, with two extraction types and two liquid chromatographic separation methods. The first extraction method investigated the acidification of the sample followed by solid-phase extraction (SPE) using a weak anion exchange cartridge. The second method used an acetonitrile extraction followed by SPE using a graphitized non-porous carbon cartridge. The extracts were separated using a reversed-phase C{sub 8} stationary phase and a pentafluorophenyl (PFP) stationary phase. Measured values from both methods for the two human serum SRMs, 1957 and 1958, agreed with reference values on the Certificates of Analysis. Perfluorooctane sulfonate (PFOS) values were obtained for the first time in human plasma SRM 1950 with good reproducibility among the methods (below 5% relative standard deviation). The nominal mass interference from taurodeoxycholic acid, which has caused over estimation of the amount of PFOS in biological samples, was separated from PFOS using the PFP stationary phase. Other PFCs were also detected in SRM 1950 and are reported. SRM 1950 can be used as a control material for human biomonitoring studies and as an aid to develop new measurement methods. (orig.)

  7. Standard test method for measurement of oxidation-reduction potential (ORP) of soil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a procedure and related test equipment for measuring oxidation-reduction potential (ORP) of soil samples removed from the ground. 1.2 The procedure in Section 9 is appropriate for field and laboratory measurements. 1.3 Accurate measurement of oxidation-reduction potential aids in the analysis of soil corrosivity and its impact on buried metallic structure corrosion rates. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Standard test method for abrasiveness of ink-impregnated fabric printer ribbons and other web materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of the abrasiveness of ink-impregnated fabric printer ribbons and other web materials by means of a sliding wear test. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard test method for wear testing with a pin-on-disk apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers a laboratory procedure for determining the wear of materials during sliding using a pin-on-disk apparatus. Materials are tested in pairs under nominally non-abrasive conditions. The principal areas of experimental attention in using this type of apparatus to measure wear are described. The coefficient of friction may also be determined. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the determination of nonvolatile residue (NVR) fallout in environmentally controlled areas used for the assembly, testing, and processing of spacecraft. 1.2 The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is left to the user to infer the relationship between the NVR found on the sampling plate surface and that found on any other surfaces. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  11. Standard test method for measurement of corrosion potentials of Aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a procedure for measurement of the corrosion potential (see Note 1) of an aluminum alloy in an aqueous solution of sodium chloride with enough hydrogen peroxide added to provide an ample supply of cathodic reactant. Note 1—The corrosion potential is sometimes referred to as the open-circuit solution or rest potential. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Standard Test Method for Hail Impact Resistance of Aerospace Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of the impact resistance of an aerospace transparent enclosure, hereinafter called windshield, during hailstorm conditions using simulated hailstones consisting of ice balls molded under tightly controlled conditions. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Section 7.

  13. Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware. 1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Standard test methods for elevated temperature tension tests of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedure and equipment for the determination of tensile strength, yield strength, elongation, and reduction of area of metallic materials at elevated temperatures. 1.2 Determination of modulus of elasticity and proportional limit are not included. 1.3 Tension tests under conditions of rapid heating or rapid strain rates are not included. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Standard test method for plastic strain ratio r for sheet metal

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers special tension testing for the measurement of the plastic strain ratio, r, of sheet metal intended for deep-drawing applications. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Standard practice for digital imaging and communication nondestructive evaluation (DICONDE) for computed radiography (CR) test methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice facilitates the interoperability of computed radiography (CR) imaging and data acquisition equipment by specifying image data transfer and archival storage methods in commonly accepted terms. This practice is intended to be used in conjunction with Practice E2339 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE). Practice E2339 defines an industrial adaptation of the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, storage and archival storage. The goal of Practice E2339, commonly referred to as DICONDE, is to provide a standard that facilitates the display and analysis of NDE results on any system conforming to the DICONDE standard. Toward that end, Practice E2339 provides a data dictionary and a set of information modules that are applicable to all NDE modalities. This practice supplements Practice E2339 by providing information objec...

  17. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  18. Standard test method for plutonium by Iron (II)/Chromium (VI) amperometric titration

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of plutonium in unirradiated nuclear-grade plutonium dioxide, uranium-plutonium mixed oxides with uranium (U)/plutonium (Pu) ratios up to 21, plutonium metal, and plutonium nitrate solutions. Optimum quantities of plutonium to measure are 7 to 15 mg. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Standard Test Method for Water Absorption of Core Materials for Structural Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method covers the determination of the relative amount of water absorption by various types of structural core materials when immersed or in a high relative humidity environment. This test method is intended to apply to only structural core materials; honeycomb, foam, and balsa wood. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. The Method of Eichhorn with Non-Standard Projections for a Single Plate

    Science.gov (United States)

    Cardona, O.; Corona-Galindo, M.

    1990-11-01

    RESUMEN. Se desarrollan las expresiones para el metodo de Eichhorn en astrometria para proyecciones diferentes a la estandar. El se usa para obtener las coordenadas esfericas de estrellas en placas astron6micas cuando las variables contienen errores. ABSTRACT. We develop the expressions for the Eichhorn's Method in astrometry for non-standard projections. The method is used to obtain spherical coordinates of stars in astronomical plates, when all the variables have errors. Key words: ASTROMETRY

  2. Multigrid method based on a space-time approach with standard coarsening for parabolic problems

    NARCIS (Netherlands)

    S.R. Franco (Sebastião Romero); F.J. Gaspar Lorenz (Franscisco); M.A. Villela Pinto (Marcio Augusto); C. Rodrigo (Carmen)

    2018-01-01

    textabstractIn this work, a space-time multigrid method which uses standard coarsening in both temporal and spatial domains and combines the use of different smoothers is proposed for the solution of the heat equation in one and two space dimensions. In particular, an adaptive smoothing strategy,

  3. Standard test method for measurement of 235U fraction using enrichment meter principle

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the quantitative determination of the fraction of 235U in uranium using measurement of the 185.7 keV gamma-ray produced during the decay of 235U. 1.2 This test method is applicable to items containing homogeneous uranium-bearing materials of known chemical composition in which the compound is considered infinitely thick with respect to 185.7 keV gamma-rays. 1.3 This test method can be used for the entire range of 235U fraction as a weight percent, from depleted (0.2 % 235U) to highly enriched (97.5 % 235U). 1.4 Measurement of items that have not reached secular equilibrium between 238U and 234Th may not produce the stated bias when low-resolution detectors are used with the computational method listed in Annex A2. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety co...

  4. Non-standard perturbative methods for the effective potential in λφ4 QFT

    International Nuclear Information System (INIS)

    Okopinska, A.

    1986-07-01

    The effective potential in scalar QFT is calculated in the non-standard perturbative methods and compared with the conventional loop expansion. In the space time dimensions 0 and 1 the results are compared with the ''exact'' effective potential obtained numerically. In 4 dimensions we show that λφ 4 theory is non-interacting. (author)

  5. Next Generation Science Standards: A National Mixed-Methods Study on Teacher Readiness

    Science.gov (United States)

    Haag, Susan; Megowan, Colleen

    2015-01-01

    Next Generation Science Standards (NGSS) science and engineering practices are ways of eliciting the reasoning and applying foundational ideas in science. As research has revealed barriers to states and schools adopting the NGSS, this mixed-methods study attempts to identify characteristics of professional development (PD) that will support NGSS…

  6. Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Cole, P. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Halverson, M. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-01

    This guidance document was prepared using the input from the meeting summarized in the draft CSI Roadmap to provide Building America research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America innovations arising in and/or stemming from codes, standards, and rating methods.

  7. Comparison of PCR with Standard Method (MPN for detection of bacterial contamination in drinking water

    Directory of Open Access Journals (Sweden)

    Fatemeh Dehghan

    2014-11-01

    Full Text Available Background: Detection of bacterial contamination in drinking water by culture method is a time and cost consuming method and spends a few days depending on contamination degree. However, the people use the tap water during that time. Molecular methods are rapid and sensitive. In this study a rapid Multiplex PCR method was used for rapid analysis both coliform bacteria and E.coli, and probable detection of VBNC bacteria in drinking water, the experiments were performed in bacteriological lab of water and Wastewater Corporation in Markazi province. Material and Methods:Amplification of a fragment from each of lacZ and uidA genes in a Multiplex PCR was used for detection of coliforms. Eight samples was taken from Arak drinking water system including 36 samples of wells, 41 samples of water distribution network and 3 samples from water storages were examined by amplification of lacZ and uidA genes in a Multiplex PCR. Equivalently, the MPN test was applied as a standard method for all samples for comparison of results. Standard bacteria, pure bacteria isolated from positive MPN and CRM were examined by PCR and MPN method. Results: The result of most samples water network, water storages, and water well were same in both MPN and PCR method .The results of standard bacteria and pure cultures of bacteria isolated from positive MPN and CRM confirmed the PCR method. Five samples were positive in PCR but negative in MPN method. Duration time of PCR was decreased about 105 min by changing the PCR program and electrophoreses factors. Conclusion: The Multiplex PCR can detect coliform bacteria and E.coli synchronous in drinking water.

  8. Standard test method for determining nodularity and nodule count in ductile iron using image analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is used to determine the percent nodularity and the nodule count per unit area (that is, number of nodules per mm2) using a light microscopical image of graphite in nodular cast iron. Images generated by other devices, such as a scanning electron microscope, are not specifically addressed, but can be utilized if the system is calibrated in both x and y directions. 1.2 Measurement of secondary or temper carbon in other types of cast iron, for example, malleable cast iron or in graphitic tool steels, is not specifically included in this standard because of the different graphite shapes and sizes inherent to such grades 1.3 This standard deals only with the recommended test method and nothing in it should be construed as defining or establishing limits of acceptability or fitness for purpose of the material tested. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address al...

  9. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standardization of shape memory alloy test methods toward certification of aerospace applications

    Science.gov (United States)

    Hartl, D. J.; Mabe, J. H.; Benafan, O.; Coda, A.; Conduit, B.; Padan, R.; Van Doren, B.

    2015-08-01

    The response of shape memory alloy (SMA) components employed as actuators has enabled a number of adaptable aero-structural solutions. However, there are currently no industry or government-accepted standardized test methods for SMA materials when used as actuators and their transition to commercialization and production has been hindered. This brief fast track communication introduces to the community a recently initiated collaborative and pre-competitive SMA specification and standardization effort that is expected to deliver the first ever regulatory agency-accepted material specification and test standards for SMA as employed as actuators for commercial and military aviation applications. In the first phase of this effort, described herein, the team is working to review past efforts and deliver a set of agreed-upon properties to be included in future material certification specifications as well as the associated experiments needed to obtain them in a consistent manner. Essential for the success of this project is the participation and input from a number of organizations and individuals, including engineers and designers working in materials and processing development, application design, SMA component fabrication, and testing at the material, component, and system level. Going forward, strong consensus among this diverse body of participants and the SMA research community at large is needed to advance standardization concepts for universal adoption by the greater aerospace community and especially regulatory bodies. It is expected that the development and release of public standards will be done in collaboration with an established standards development organization.

  11. Standard test method for ball punch deformation of metallic sheet material

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the procedure for conducting the ball punch deformation test for metallic sheet materials intended for forming applications. The test applies to specimens with thicknesses between 0.008 and 0.080 in. (0.20 and 2.00 mm). 1.2 The values stated in inch–pound units are to be regarded as the standard. Note 1—The ball punch deformation test is intended to replace the Olsen cup test by standardizing many of the test parameters that previously have been left to the discretion of the testing laboratory. Note 2—The modified Erichsen test has been standardized in Europe. The main differences between the ball punch deformation test and the Erichsen test are the diameters of the penetrator and the dies. Erichsen cup heights are given in SI units. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does...

  12. Standardization of reagents and methods used in cytological and histological practice with emphasis on dyes, stains and chromogenic reagents

    DEFF Research Database (Denmark)

    Lyon, H O; De Leenheer, A P; Horobin, R W

    1994-01-01

    The need for the standardization of reagents and methods used in the histology laboratory is demonstrated. After definitions of dyes, stains, and chromogenic reagents, existing standards and standards organizations are discussed. This is followed by practical instructions on how to standardize dyes...

  13. Method and platform standardization in MRM-based quantitative plasma proteomics.

    Science.gov (United States)

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This

  14. Application of quantitative salt iodine analysis compared with the standard method.

    Science.gov (United States)

    Chongchirasiri, S; Pattanachak, S; Putrasreni, N; Suwanik, R; Pattanachak, H; Tojinda, N; Pleehachinda, R

    2001-06-01

    Laboratory investigation of 50 iodated salt samples (from producers, households, markets etc) were studied at the Research Nuclear Medicine Building, Siriraj Hospital. Two methods for the determination of iodine in salt are herein described. The standard method as recommended by The Programme Against Micronutrient Malnutrition (PAMM) / The Micronutrient Initiative (MI)/ The International Council for Control of Iodine Deficiency Disorders (ICCIDD) was the iodometric titration method. The starch-KI salt iodine quantitative method was developed in our laboratory for validation purposes. This method is high in precision, accuracy, sensitivity as well as specificity. The coefficient of variation (%CV) for intra and inter assay was below 10. Iodine contents as low as 10 ppm, could be detected. The proposed starch-KI method offered some advantages: e.g. not complicated, easier to learn and easier to perform competently, could be applied for spot qualitative test and readily performed outside the laboratory. The results obtained by the starch-KI method correlated well with the standard method (y = 0.98x - 3.22, r = 0.99).

  15. Standard Test Methods for Microscopical Sizing and Counting Particles from Aerospace Fluids on Membrane Filters

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the size distribution and quantity of particulate matter contamination from aerospace fluids isolated on a membrane filter. The microscopical techniques described may also be applied to other properly prepared samples of small particles. Two test methods are described for sizing particles as follows: 1.1.1 Test Method A—Particle sizes are measured as the diameter of a circle whose area is equal to the projected area of the particle. 1.1.2 Test Method B—Particle sizes are measured by their longest dimension. 1.2 The test methods are intended for application to particle contamination determination of aerospace fluids, gases, surfaces, and environments. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 These test methods do not provide for sizing particles smaller than 5 μm. Note 1—Results of these methods are subject to variables inherent in any statistical method. The...

  16. Standard test method for radiochemical determination of plutonium in Soil by alpha spectroscopy

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of plutonium in soils at levels of detection dependent on count time, sample size, detector, background, and tracer yield. This test method describes one acceptable approach to the determination of plutonium in soil. 1.2 This test method is designed for 10 g of soil, previously collected and treated as described in Practices C998 and C999, but sample sizes up to 50 g may be analyzed by this test method. This test method may not be able to completely dissolve all forms of plutonium in the soil matrix. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 9.

  17. Evaluation Standard for Safety Coefficient of Roller Compacted Concrete Dam Based on Finite Element Method

    Directory of Open Access Journals (Sweden)

    Bo Li

    2014-01-01

    Full Text Available The lack of evaluation standard for safety coefficient based on finite element method (FEM limits the wide application of FEM in roller compacted concrete dam (RCCD. In this paper, the strength reserve factor (SRF method is adopted to simulate gradual failure and possible unstable modes of RCCD system. The entropy theory and catastrophe theory are used to obtain the ultimate bearing resistance and failure criterion of the RCCD. The most dangerous sliding plane for RCCD failure is found using the Latin hypercube sampling (LHS and auxiliary analysis of partial least squares regression (PLSR. Finally a method for determining the evaluation standard of RCCD safety coefficient based on FEM is put forward using least squares support vector machines (LSSVM and particle swarm optimization (PSO. The proposed method is applied to safety coefficient analysis of the Longtan RCCD in China. The calculation shows that RCCD failure is closely related to RCCD interface strength, and the Longtan RCCD is safe in the design condition. Considering RCCD failure characteristic and combining the advantages of several excellent algorithms, the proposed method determines the evaluation standard for safety coefficient of RCCD based on FEM for the first time and can be popularized to any RCCD.

  18. Stability and non-standard finite difference method of the generalized Chua's circuit

    KAUST Repository

    Radwan, Ahmed G.

    2011-08-01

    In this paper, we develop a framework to obtain approximate numerical solutions of the fractional-order Chua\\'s circuit with Memristor using a non-standard finite difference method. Chaotic response is obtained with fractional-order elements as well as integer-order elements. Stability analysis and the condition of oscillation for the integer-order system are discussed. In addition, the stability analyses for different fractional-order cases are investigated showing a great sensitivity to small order changes indicating the poles\\' locations inside the physical s-plane. The GrnwaldLetnikov method is used to approximate the fractional derivatives. Numerical results are presented graphically and reveal that the non-standard finite difference scheme is an effective and convenient method to solve fractional-order chaotic systems, and to validate their stability. © 2011 Elsevier Ltd. All rights reserved.

  19. Standard test method for conducting erosion tests by solid particle impingement using gas jets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers the determination of material loss by gas-entrained solid particle impingement erosion with jetnozzle type erosion equipment. This test method may be used in the laboratory to measure the solid particle erosion of different materials and has been used as a screening test for ranking solid particle erosion rates of materials in simulated service environments (1,2 ). Actual erosion service involves particle sizes, velocities, attack angles, environments, and so forth, that will vary over a wide range (3-5). Hence, any single laboratory test may not be sufficient to evaluate expected service performance. This test method describes one well characterized procedure for solid particle impingement erosion measurement for which interlaboratory test results are available. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determi...

  20. Preliminary researches to standardize a method of quantitative analysis on Lactobacillus acidophilus in poultry feed

    Directory of Open Access Journals (Sweden)

    Daniele Gallazzi

    2010-01-01

    Full Text Available The study focuses on the method and the problems about quantitative analyses in the research on Lactobacillus acidophilus after its addition to commercial poultry-feed, whose rough grinding is not suitable for the “IDF Standard quantitative method for lactic acid bacteria count at 37°C” employed in dairy products. Poultry-feed was prepared every month. A sample was collected before and after adding Lactobacillus acidophilus, while analyses were carried out respectively at T 0, 15 and 28 days after the food storage at 4-6°C. The best outcomes (more 30% of recovered cells compared to the standard method resulted from samples subjected to the homogenization and the addition of Skim Milk Powder.

  1. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  2. The standard centrifuge method accurately measures vulnerability curves of long-vesselled olive stems.

    Science.gov (United States)

    Hacke, Uwe G; Venturas, Martin D; MacKinnon, Evan D; Jacobsen, Anna L; Sperry, John S; Pratt, R Brandon

    2015-01-01

    The standard centrifuge method has been frequently used to measure vulnerability to xylem cavitation. This method has recently been questioned. It was hypothesized that open vessels lead to exponential vulnerability curves, which were thought to be indicative of measurement artifact. We tested this hypothesis in stems of olive (Olea europea) because its long vessels were recently claimed to produce a centrifuge artifact. We evaluated three predictions that followed from the open vessel artifact hypothesis: shorter stems, with more open vessels, would be more vulnerable than longer stems; standard centrifuge-based curves would be more vulnerable than dehydration-based curves; and open vessels would cause an exponential shape of centrifuge-based curves. Experimental evidence did not support these predictions. Centrifuge curves did not vary when the proportion of open vessels was altered. Centrifuge and dehydration curves were similar. At highly negative xylem pressure, centrifuge-based curves slightly overestimated vulnerability compared to the dehydration curve. This divergence was eliminated by centrifuging each stem only once. The standard centrifuge method produced accurate curves of samples containing open vessels, supporting the validity of this technique and confirming its utility in understanding plant hydraulics. Seven recommendations for avoiding artefacts and standardizing vulnerability curve methodology are provided. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  3. Standard test method for Young's modulus, tangent modulus, and chord modulus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers the determination of Young's modulus, tangent modulus, and chord modulus of structural materials. This test method is limited to materials in which and to temperatures and stresses at which creep is negligible compared to the strain produced immediately upon loading and to elastic behavior. 1.2 Because of experimental problems associated with the establishment of the origin of the stress-strain curve described in 8.1, the determination of the initial tangent modulus (that is, the slope of the stress-strain curve at the origin) and the secant modulus are outside the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory require...

  4. Standard test method for measurement of roll wave optical distortion in heat-treated flat glass

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method is applicable to the determination of the peak-to-valley depth and peak-to-peak distances of the out-of-plane deformation referred to as roll wave which occurs in flat, heat-treated architectural glass substrates processed in a heat processing continuous or oscillating conveyance oven. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This test method does not address other flatness issues like edge kink, ream, pocket distortion, bow, or other distortions outside of roll wave as defined in this test method. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Standard method for economic analyses of inertial confinement fusion power plants

    International Nuclear Information System (INIS)

    Meier, W.R.

    1986-01-01

    A standard method for calculating the total capital cost and the cost of electricity for a typical inertial confinement fusion electric power plant has been developed. A standard code of accounts at the two-digit level is given for the factors making up the total capital cost of the power plant. Equations are given for calculating the indirect capital costs, the project contingency, and the time-related costs. Expressions for calculating the fixed charge rate, which is necessary to determine the cost of electricity, are also described. Default parameters are given to define a reference case for comparative economic analyses

  7. Standard test method for uranium and plutonium concentrations and isotopic abundances by thermal ionization mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of the concentration and isotopic composition of uranium and plutonium in solutions. The purified uranium or plutonium from samples ranging from nuclear materials to environmental or bioassay matrices is loaded onto a mass spectrometric filament. The isotopic ratio is determined by thermal ionization mass spectrometry, the concentration is determined by isotope dilution. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover procedures for subsampling and for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride UF6. Most of these test methods are in routine use to determine conformance to UF6 specifications in the Enrichment and Conversion Facilities. 1.2 The analytical procedures in this document appear in the following order: Note 1—Subcommittee C26.05 will confer with C26.02 concerning the renumbered section in Test Methods C761 to determine how concerns with renumbering these sections, as analytical methods are replaced with stand-alone analytical methods, are best addressed in subsequent publications. Sections Subsampling of Uranium Hexafluoride 7 - 10 Gravimetric Determination of Uranium 11 - 19 Titrimetric Determination of Uranium 20 Preparation of High-Purity U3O 8 21 Isotopic Analysis 22 Isotopic Analysis by Double-Standard Mass-Spectrometer Method 23 - 29 Determination of Hydrocarbons, Chlorocarbons, and Partially Substitut...

  9. A Comparison of Three Methods for Computing Scale Score Conditional Standard Errors of Measurement. ACT Research Report Series, 2013 (7)

    Science.gov (United States)

    Woodruff, David; Traynor, Anne; Cui, Zhongmin; Fang, Yu

    2013-01-01

    Professional standards for educational testing recommend that both the overall standard error of measurement and the conditional standard error of measurement (CSEM) be computed on the score scale used to report scores to examinees. Several methods have been developed to compute scale score CSEMs. This paper compares three methods, based on…

  10. Bootstrap-based methods for estimating standard errors in Cox's regression analyses of clustered event times.

    Science.gov (United States)

    Xiao, Yongling; Abrahamowicz, Michal

    2010-03-30

    We propose two bootstrap-based methods to correct the standard errors (SEs) from Cox's model for within-cluster correlation of right-censored event times. The cluster-bootstrap method resamples, with replacement, only the clusters, whereas the two-step bootstrap method resamples (i) the clusters, and (ii) individuals within each selected cluster, with replacement. In simulations, we evaluate both methods and compare them with the existing robust variance estimator and the shared gamma frailty model, which are available in statistical software packages. We simulate clustered event time data, with latent cluster-level random effects, which are ignored in the conventional Cox's model. For cluster-level covariates, both proposed bootstrap methods yield accurate SEs, and type I error rates, and acceptable coverage rates, regardless of the true random effects distribution, and avoid serious variance under-estimation by conventional Cox-based standard errors. However, the two-step bootstrap method over-estimates the variance for individual-level covariates. We also apply the proposed bootstrap methods to obtain confidence bands around flexible estimates of time-dependent effects in a real-life analysis of cluster event times.

  11. Evaluation of standardized test methods to characterize fiber reinforced cement composites

    DEFF Research Database (Denmark)

    Paegle, Ieva; Fischer, Gregor

    2011-01-01

    This paper describes an investigation of standardized test methods to characterize fiber reinforced cementitious composites in terms of their behavior under flexural loading and its relation to their tensile stress-deformation response. Flexural testing and derivation of the tensile stress......-deformation response are preferred in standardized testing of Fiber Reinforced Cement Composites (FRCC) over the direct assessment of the tensile behavior because of the more convenient test setup and ease of specimen preparation. Four-point bending tests were carried out to evaluate the flexural response of FRCC...... and their results are compared to data obtained from direct tensile testing. The details of the formation of cracking are an important underlying assumption in the standardized evaluation procedures as well as in the established correlation models between flexural and tensile behavior. This detail has been...

  12. Standard Test Method for Hydrophobic Surface Films by the Water-Break Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces, the sensitivity of the test may be significantly decreased. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Pamala C.; Halverson, Mark A.

    2013-09-01

    The U.S. Department of Energy’s (DOE) Building America program implemented a new Codes and Standards Innovation (CSI) Team in 2013. The Team’s mission is to assist Building America (BA) research teams and partners in identifying and resolving conflicts between Building America innovations and the various codes and standards that govern the construction of residences. A CSI Roadmap was completed in September, 2013. This guidance document was prepared using the information in the CSI Roadmap to provide BA research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America (BA) innovations arising in and/or stemming from codes, standards, and rating methods. For more information on the BA CSI team, please email: CSITeam@pnnl.gov

  14. Standard Test Method for Hydrophobic Surface Films by the Atomizer Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1965-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of fractional molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces the sensitivity of the test may be significantly decreased. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. A novel method for standardized application of fungal spore coatings for mosquito exposure bioassays

    Directory of Open Access Journals (Sweden)

    Knols Bart GJ

    2010-01-01

    Full Text Available Abstract Background Interest in the use of fungal entomopathogens against malaria vectors is growing. Fungal spores infect insects via the cuticle and can be applied directly on the insect to evaluate infectivity. For flying insects such as mosquitoes, however, application of fungal suspensions on resting surfaces is more realistic and representative of field settings. For this type of exposure, it is essential to apply specific amounts of fungal spores homogeneously over a surface for testing the effects of fungal dose and exposure time. Contemporary methods such as spraying or brushing spore suspensions onto substrates do not produce the uniformity and consistency that standardized laboratory assays require. Two novel fungus application methods using equipment developed in the paint industry are presented and compared. Methods Wired, stainless steel K-bars were tested and optimized for coating fungal spore suspensions onto paper substrates. Different solvents and substrates were evaluated. Two types of coating techniques were compared, i.e. manual and automated coating. A standardized bioassay set-up was designed for testing coated spores against malaria mosquitoes. Results K-bar coating provided consistent applications of spore layers onto paper substrates. Viscous Ondina oil formulations were not suitable and significantly reduced spore infectivity. Evaporative Shellsol T solvent dried quickly and resulted in high spore infectivity to mosquitoes. Smooth proofing papers were the most effective substrate and showed higher infectivity than cardboard substrates. Manually and mechanically applied spore coatings showed similar and reproducible effects on mosquito survival. The standardized mosquito exposure bioassay was effective and consistent in measuring effects of fungal dose and exposure time. Conclusions K-bar coating is a simple and consistent method for applying fungal spore suspensions onto paper substrates and can produce coating layers

  16. Standard test methods for estimating the depth of decarburization of steel specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 These test methods cover procedures for estimating the depth of decarburization of steels irrespective of the composition, matrix microstructure, or section shape. The following basic procedures may be used: 1.1.1 Screening methods. 1.1.2 Microscopical methods. 1.1.3 Microindentation hardness methods. 1.1.4 Chemical analysis methods. 1.2 In case of a dispute, the rigorous quantitative or lineal analysis method (see 7.3.5 and 7.3.6) shall be the referee method. These methods can be employed with any cross-sectional shape. The chemical analytical methods generally reveal a greater depth of decarburization than the microscopical methods but are limited to certain simple shapes and by availability of equipment. These techniques are generally reserved for research studies. The microindentation hardness method is suitable for accurate measurements of hardened structures with relatively homogeneous microstructures. 1.3 The values stated in SI units are to be regarded as standard. The inch-pound equivalents...

  17. Analysis of Indonesian educational system standard with KSIM cross-impact method

    Science.gov (United States)

    Arridjal, F.; Aldila, D.; Bustamam, A.

    2017-07-01

    The Result of The Programme of International Student Assessment (PISA) on 2012 shows that Indonesia is on 64'th position from 65 countries in Mathematics Mean Score. The 2013 Learning Curve Mapping, Indonesia is included in the 10th category of countries with the lowest performance on cognitive skills aspect, i.e. 37'th position from 40 countries. Competency is built by 3 aspects, one of them is cognitive aspect. The low result of mapping on cognitive aspect, describe the low of graduate competences as an output of Indonesia National Education System (INES). INES adopting a concept Eight Educational System Standards (EESS), one of them is graduate competency standard which connected directly with Indonesia's students. This research aims is to model INES by using KSIM cross-impact. Linear regression models of EESS constructed using the accreditation national data of Senior High Schools in Indonesia. The results then interpreted as impact value on the construction of KSIM cross-impact INES. The construction is used to analyze the interaction of EESS and doing numerical simulation for possible public policy in the education sector, i.e. stimulate the growth of education staff standard, content, process and infrastructure. All simulations of public policy has been done with 2 methods i.e with a multiplier impact method and with constant intervention method. From numerical simulation result, it is shown that stimulate the growth standard of content in the construction KSIM cross-impact EESS is the best option for public policy to maximize the growth of graduate competency standard.

  18. Bioelectrical impedance analysis (BIA): a proposal for standardization of the classical method in adults

    Science.gov (United States)

    González-Correa, C. H.; Caicedo-Eraso, J. C.

    2012-12-01

    The accuracy of BIA measurements is limited by different sources of error such as physical model, cross sectional area, ethnicity, body hydration, age and level of body fat among other variables. Equation for each population is required as they can produce overestimation when manufacturer's equations are used. The classical measurements hand to foot has shown better correlation against hydrodensitometry than foot to foot or hand to hand. However there is a lack for an accepted standard of BIA procedures. This is compounded when there is not a good report of the BIA study's methodology; hence the comparability between the results is poor and reduces the reliability of the method. Perhaps, standardization of methods would be the first step for BIA studies to move forward and subsequently improve its accuracy. Standardized procedures could also minimize the impact of these variables on studies results. The aim of this study was to propose a protocol as a checklist to standardize BIA procedures and produce comparable results from future studies performed with the classic hand-foot configuration in adults.

  19. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  20. A novel method of drift-scanning stars suppression based on the standardized linear filter

    Science.gov (United States)

    Lin, Jianlin; Ping, Xijian; Hou, Guanghua; Ma, Debao

    2011-11-01

    A large number of stars in the drift-scanning star image have interfered with the detection of small target, this paper proposes an adaptive linear filtering method to achieve the small target detection by suppressing the stars. Firstly, the characteristics of stars, interest target and noise three different representative objects in the star image are analyzed, then the standardized linear filter is constructed to suppress the stars. For the purpose of decreasing the influence region of stars filtering uniformly, a gradient linear filter is constructed to modify the stars suppression method with the standardized linear filter. Then the filter parameter selection method is given. Finally, a multi-frame target track experiment on the real drift-scanning data is made to testify the validity of the proposed method. With the processing results of different methods, it has been showed that the proposed method for suppressing stars with different length and lean angle has a better effect, higher robustness and easier application than the others.

  1. MUSQA: a CS method to build a multi-standard quality management system

    Science.gov (United States)

    Cros, Elizabeth; Sneed, Isabelle

    2002-07-01

    CS Communication & Systèmes, through its long quality management experience, has been able to build and evolve its Quality Management System according to clients requirements, norms, standards and models (ISO, DO178, ECSS, CMM, ...), evolving norms (transition from ISO 9001:1994 to ISO 9001:2000) and the TQM approach, being currently deployed. The aim of this paper is to show how, from this enriching and instructive experience, CS has defined and formalised its method: MuSQA (Multi-Standard Quality Approach). This method allows to built a new Quality Management System or simplify and unify an existing one. MuSQA objective is to provide any organisation with an open Quality Management System, which is able to evolve easily and turns to be a useful instrument for everyone, operational as well as non-operational staff.

  2. Standard test method for color and color difference of whitewares by abriged spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method describes the instrumental measurement of the reflection properties and color of ceramic glazes and other whitewares by the use of a spectrophotometer or spectrocolorimeter with a hemispherical optical measuring system, such as an integrating sphere. 1.2 The test method is suitable for use with most specimens having an exterior flat surface large enough to cover the spectrophotometer sample port. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Electrocardiography interpretation training in emergency medicine: methods, resources, competency assessment, and national standardization

    OpenAIRE

    Özel, Betül Akbuğa; Demircan, Ahmet; Keleş, Ayfer; Bildik, Fikret; Özel, Deniz; Ergin, Mehmet; Günaydin, Gül Pamukçu

    2015-01-01

    Objective(s). The aim of this study was to evaluate the status of electrocardiography (ECG) training in emergency medicine residency programs in Turkey, and the attitude of the program representatives towards standardization of such training. Methods. This investigation was planned as a cross-sectional study. An 18-item questionnaire was distributed to directors of residency programs. Responses were evaluated using SPSS (v.16.0), and analyzed using the chi-square test. Results. Thirty...

  4. A Method For Determination And Standardization Of Performance Parameters For Aircrafts With Electric Drives

    Directory of Open Access Journals (Sweden)

    Jakielaszek Zbigniew

    2014-12-01

    Full Text Available The study outlines the technique for flight tests carried out for a plane powered by an electric drive and the method for standardization of performance parameters applicable to evaluation of test results. Due to the relatively new type of drive, which is an electric motor, the literature references provide no descriptions of such issues. Therefore the solutions presented in the paper are the own contribution of the research team from Air Force Institute of Technology (ITWL.

  5. A novel method for standardized application of fungal spore coatings for mosquito exposure bioassays.

    Science.gov (United States)

    Farenhorst, Marit; Knols, Bart G J

    2010-01-20

    Interest in the use of fungal entomopathogens against malaria vectors is growing. Fungal spores infect insects via the cuticle and can be applied directly on the insect to evaluate infectivity. For flying insects such as mosquitoes, however, application of fungal suspensions on resting surfaces is more realistic and representative of field settings. For this type of exposure, it is essential to apply specific amounts of fungal spores homogeneously over a surface for testing the effects of fungal dose and exposure time. Contemporary methods such as spraying or brushing spore suspensions onto substrates do not produce the uniformity and consistency that standardized laboratory assays require. Two novel fungus application methods using equipment developed in the paint industry are presented and compared. Wired, stainless steel K-bars were tested and optimized for coating fungal spore suspensions onto paper substrates. Different solvents and substrates were evaluated. Two types of coating techniques were compared, i.e. manual and automated coating. A standardized bioassay set-up was designed for testing coated spores against malaria mosquitoes. K-bar coating provided consistent applications of spore layers onto paper substrates. Viscous Ondina oil formulations were not suitable and significantly reduced spore infectivity. Evaporative Shellsol T solvent dried quickly and resulted in high spore infectivity to mosquitoes. Smooth proofing papers were the most effective substrate and showed higher infectivity than cardboard substrates. Manually and mechanically applied spore coatings showed similar and reproducible effects on mosquito survival. The standardized mosquito exposure bioassay was effective and consistent in measuring effects of fungal dose and exposure time. K-bar coating is a simple and consistent method for applying fungal spore suspensions onto paper substrates and can produce coating layers with accurate effective spore concentrations. The mosquito bioassay

  6. Standardization of the method for measurement of plasma estrone by radioimmunoassay

    International Nuclear Information System (INIS)

    Vilanova, M.S.V.; Moreira, A.C.; Sala, M.M. de; Sa, M.F.S. de

    1994-01-01

    The present paper has as objective standardize a radioimmunoassay method for measurement of plasma estrone. Ethyl ether was used for plasma extraction. The sensitivity (Minimal detectable dose) was 3,7 pg/tube; the reproducibility (inter assay error) was 8,6%; the precision (intra assay error) was 4,1%. As a biological control the plasma estrone was ml) and in 24 patients with polycystic ovarian syndrome (median = 77,9 pg/ml). (author). 6 refs, 2 figs, 2 tabs

  7. Standard method for total molybdenum in fresh alumina-base catalysts

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This test method covers the determination of molybdenum in alumina-base catalyst and has been cooperatively tested at molybdenum concentrations from 8 to 18 weight %, expressed as MoO 3 . Any component of the catalyst other than molybdenum such as iron, tungsten, etc., which is capable of being oxidized by either ferric or ceric ions after being passed through a zinc-amalgam reductor column (Jones reductor) will interfere. This standard may involve hazardous, materials, operations, and equipment

  8. Stress measurement by neutron diffraction method. Standard method using angular dispersion method and trial of using neutron IP

    International Nuclear Information System (INIS)

    Sasaki, Toshihiko; Takago, Shigeki

    2016-01-01

    This paper outlined a stress measurement method using neutrons, and introduced the application examples to stress measurement for metal-based composite materials. In the angular dispersion type measurement using a steady-state reactor type neutron source, the white beams taken out from a nuclear reactor are monochromatized (wavelength λ is a constant value) with a single crystal monochromator and utilized. As an example of measurement, there was the case as follows: the stress of a sintered material which has been put to practical use as valve seat part for automobiles was measured by the neutron method, and the deformation behavior during load was studied. This study performed neutron diffraction measurement using a residual stress analyzer (RESA: Diffractometer for Residual Stress Analysis) installed at JAEA's experimental reactor JRR-3. As a result, it was found that the stress state of the sintered composite material of Fe-Cr and TiN can be predicted with a micromechanics model. A neutron diffraction ring can be obtained using a neutron image plate (IP), where fine powder of gadolinium (Gd) was incorporated into IP for X-rays, and it can be used as an IP reader in the same way as the case of X-rays. A report has been introduced on the examination results of the highly accurate stress measurement by applying the cos α method devised for X-ray stress measurement to neutron diffraction ring. (A.O.)

  9. An isotope-dilution standard GC/MS/MS method for steroid hormones in water

    Science.gov (United States)

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.

    2013-01-01

    An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

  10. Standard Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the estimation of the electrical corrosion potential of uncoated reinforcing steel in field and laboratory concrete, for the purpose of determining the corrosion activity of the reinforcing steel. 1.2 This test method is limited by electrical circuitry. Concrete surface in building interiors and desert environments lose sufficient moisture so that the concrete resistivity becomes so high that special testing techniques not covered in this test method may be required (see 5.1.4.1). Concrete surfaces that are coated or treated with sealers may not provide an acceptable electrical circuit. The basic configuration of the electrical circuit is shown in Fig. 1. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It ...

  11. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  12. Standard Test Method for Sizing and Counting Particulate Contaminant In and On Clean Room Garments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers the determination of detachable particulate contaminant 5 m or larger, in and on the fabric of clean room garments. 1.2 This test method does not apply to nonporous fabrics such as Tyvek or Gortex. It only applies to fabrics that are porous such as cotton or polyester. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.4 This test method provides not only the traditional optical microscopic analysis but also a size distribution and surface obscuration analysis for particles on a fine-textured membrane filter or in a tape lift sample. It utilizes transmitted illumination to render all particles darker than the background for gray level detection. Particles collected on opaque plates must be transferred to a suitable membrane filter. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associat...

  13. A Case Study of Academic Writing Development Through Principled Versus Standard Clt Method at Binus University

    Directory of Open Access Journals (Sweden)

    Almodad Biduk Asmani

    2013-10-01

    Full Text Available The purpose of the research project is to investigate how far the academic writing skills of Binus University students can be developed through two conflicting CLT methods: standard and principled. The research project is expected to result in computer-animated format which can be used as one of the main tools in teaching and learning grammar at Binus University. The research project uses the qualitative approach, and thus uses verbal data. The research project involves two subject groups (experimental and control. The experimental group will receive the treatment of grammar learning by using the Principled CLT approach, while the control group receives the standard CLT approach. Survey is then conducted to the two groups so as to find out their comments on the two teaching methods. From the results of the questionnaires, it is found that Principled CLT method is favored for its knowledge and accuracy factors, while the Standard CLT is preferred for its fun and independence factors.   

  14. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

    Science.gov (United States)

    Jha, Abhinav K; Caffo, Brian; Frey, Eric C

    2016-04-07

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest

  15. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods

    International Nuclear Information System (INIS)

    Jha, Abhinav K; Frey, Eric C; Caffo, Brian

    2016-01-01

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest

  16. Standard test method for damage to contacting solid surfaces under fretting conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the studying or ranking the susceptibility of candidate materials to fretting corrosion or fretting wear for the purposes of material selection for applications where fretting corrosion or fretting wear can limit serviceability. 1.2 This test method uses a tribological bench test apparatus with a mechanism or device that will produce the necessary relative motion between a contacting hemispherical rider and a flat counterface. The rider is pressed against the flat counterface with a loading mass. The test method is intended for use in room temperature air, but future editions could include fretting in the presence of lubricants or other environments. 1.3 The purpose of this test method is to rub two solid surfaces together under controlled fretting conditions and to quantify the damage to both surfaces in units of volume loss for the test method. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5...

  17. The measurement of magnetic properties of electrical sheet steel - survey on methods and situation of standards

    CERN Document Server

    Sievert, J

    2000-01-01

    A brief review of the different requirements for magnetic measurement techniques for material research, modelling of material properties and grading of the electrical sheet steel for trade purposes is presented. In relation to the main application of laminated electrical steel, this paper deals with AC measurement techniques. Two standard methods, Epstein frame and Single Sheet Tester (SST), producing different results, are used in parallel. This dilemma was analysed in detail. The study leads to a possible solution of the problem, i.e. the possibility of converting the results of one of the two methods into the results of the other in order to satisfy the users of the Epstein method and, at the same time, to improve the acceptance of the more economical SST method.

  18. The Efficacy of Standardized Patient Feedback in Clinical Teaching: A Mixed Methods Analysis

    Directory of Open Access Journals (Sweden)

    Lisa Doyle Howley, PhD

    2004-01-01

    Full Text Available Introduction. The purpose of the current study was to investigate the effects of oral feedback from standardized patients on medical students’ overall perceptions of an educational exercise. We chose a mixed-methods approach to better understand the following research questions: Does satisfaction with the standardized patient exercise differ among those students who receive oral feedback and those who do not? What is the quality of oral feedback provided by standardized patients? Procedures. In order to address the first question, a basic randomized design comparing treatment (or those receiving SP feedback to control (those not receiving SP feedback was conducted. To address the second question, students in the treatment group were surveyed about their impressions of the quality of the feedback provided to them by their SP. One hundred and thirty six first year medical students were divided into treatment and control groups and interviewed one standardized patient during a single 20-minute encounter. Standardized patients were trained to simulate one of two outpatient cases and provide feedback using standard training materials. Both treatment and control groups completed a rating scale and questionnaire regarding their satisfaction with the encounter and students in the treatment group responded to additional questions regarding the quality of the SP feedback. Results. A one-way multivariate analysis of variance (MANOVA revealed significant differences among control and treatment groups on the seven combined dependent variables, Wilks’ =.890, F(7, 127=2.25, p<.034, ?2=.110. Students reported that the quality of SP feedback was very strong and additional qualitative analysis revealed further evidence to support the efficacy of providing oral SP feedback in a formative pre-clinical educational activity.

  19. Double Standards: Using Teachers' Perceptions to Develop a Standards-Based Technology Integration Method for Social Studies

    Science.gov (United States)

    Hineman, John M.

    2011-01-01

    This qualitative collective case study with an action research design identified teachers' perceptions of the use of technology in standards-based social studies education. Data were collected from semi-structured, one-on-one interviews conducted with a purposive sample of ten in-service social studies teachers from southwestern Pennsylvania.…

  20. Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Searching for beyond the Standard Model physics using direct and indirect methods at LHCb

    CERN Document Server

    Hall, Samuel C P; Golutvin, Andrey

    It is known that the Standard Model of particle physics is incomplete in its description of nature at a fundamental level. For example, the Standard Model can neither incorporate dark matter nor explain the matter dominated nature of the Universe. This thesis presents three analyses undertaken using data collected by the LHCb detector. Each analysis searches for indications of physics beyond the Standard Model in dierent decays of B mesons, using dierent techniques. Notably, two analyses look for indications of new physics using indirect methods, and one uses a direct approach. The rst analysis shows evidence for the rare decay $B^{+} \\rightarrow D^{+}_{s}\\phi$ with greater than 3 $\\sigma$ signicance; this also constitutes the rst evidence for a fullyhadronic annihilation-type decay of a $B^{+}$ meson. A measurement of the branching fraction of the decay $B^{+} \\rightarrow D^{+}_{s}\\phi$ is seen to be higher than, but still compatible with, Standard Model predictions. The CP-asymmetry of the decay is also ...

  2. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Nickel

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reaction 58Ni(n,p)58Co. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 2.1 MeV and for irradiation times up to about 200 days in the absence of high thermal neutron fluence rates (for longer irradiations, see Practice E 261). 1.3 With suitable techniques fission-neutron fluence rates densities above 107 cm−2·s−1 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note—The burnup corrections were com...

  3. Standard Test Method for Obtaining Char Density Profile of Ablative Materials by Machining and Weighing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the determination of the char density profile of a charred ablator that can be used with the following limitations: 1.1.1 The local surface imperfections must be removed, and the char must be able to be machined off in a plane parallel to the char-virgin material interface before the density profiles can be determined. 1.1.2 The char must be strong enough to withstand the machining and handling techniques employed. 1.1.3 The material should have orderly density variations. The total thickness of the char and degradation zone must be larger than the machining thicknesses required. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.2.1 Exception—Certain inch-pound equivalent units are included in parentheses for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establis...

  4. A Study on the Improvement of Safety Testing Standards and Methods for Mammography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seon Hyeong; Jung, Ah Young; Yong, Hwan Seok; Kim, Do Wan; Jang, Gi Won; Cha, Sang Hoon [Korean Institute for Accreditation of Medical Imaging, Seoul (Korea, Republic of); Jo, Sang Won [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Park, Ji Koon [Industry-Academic Cooperation Foundation, International University of Korea, Jinju (Korea, Republic of)

    2012-11-15

    To establish the improved national safety testing standards and methods for mammography. We investigated and compared the current status of mammographic equipment installation with the national and international safety and quality control programs and methods. We established and verified the draft for safety testing standards and methods. We propose that the investigations of the conductor system, hardware leakage radiation profile, illumination intensity test, comparison between X-ray and light photon exposure, X-ray dose exposure on the chest wall, compression equipment size, timing equipment, and the average effective radiation dose, should all be maintained as they are in the present state without any changes. However, the exposure radiation dose reproducibility, kVp and mAs, and the half value layer tests should be reconsidered and revised. Moreover, compression pressure and autonomic exposure control system (AEC) tests should be included as new criteria. Other parameter controls included in the phantom image analysis which overlap with total quality assurance should be excluded. We recommend that AEC and compression pressure tests should be included as new criteria and the methods for the exposure radiation dose reproducibility, kVp, and mAs, and half value layer tests should be reconsidered and revised.

  5. Determination of free acid by standard addition method in potassium thiocyanate

    International Nuclear Information System (INIS)

    Baumann, E.W.

    1982-06-01

    The free acid content of solutions containing hydrolyzable ions has been determined potentiometrically by a standard addition method. Two increments of acid are added to the sample in 1M potassium thiocyanate solution. The sample concentration is calculated by solution of three simultaneous Nernst equations. The method has been demonstrated for solutions containing Al 3+ , Cr 3+ , Fe 3+ , Hg 2+ , Ni 2+ , Th 4+ , or UO 2 2+ with a metal-to-acid ratio of < 2.5. The method is suitable for determination of 10 μmoles acid in 10 mL total volume. The accuracy can be judged from the agreement of the Nernst slopes found in the presence and absence of hydrolyzable ions. The relative standard deviation is < 2.5%. The report includes a survey of experiments with thermometric, pH, and Gran plot titrations in a variety of complexants, from which the method was evolved. Also included is a literature survey of sixty references, a discussion of the basic measurements, and a complete analytical procedure

  6. Standard Test Methods for Properties of Continuous Filament Carbon and Graphite Fiber Tows

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 These test methods cover the preparation and tensile testing of resin-impregnated and consolidated test specimens made from continuous filament carbon and graphite yarns, rovings, and tows to determine their tensile properties. 1.2 These test methods also cover the determination of the density and mass per unit length of the yarn, roving, or tow to provide supplementary data for tensile property calculation. 1.3 These test methods include a procedure for sizing removal to provide the preferred desized fiber samples for density measurement. This procedure may also be used to determine the weight percent sizing. 1.4 These test methods include a procedure for determining the weight percent moisture adsorption of carbon or graphite fiber. 1.5 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of t...

  7. Application of the dynamic control rod reactivity measurement method to Korea standard nuclear power plants

    International Nuclear Information System (INIS)

    Lee, E. K.; Shin, H. C.; Bae, S. M.; Lee, Y. G.

    2004-01-01

    To measure and validate the worth of control bank or shutdown bank, the dynamic control rod reactivity measurement (DCRM) technique has been developed and applied to six cases of Low Power Physics Tests of PWRs including Korea Standard Nuclear Power plant (KSNP) based on the CE System 80 NSSS. Through the DORT results for each two ex-ore detector response and the three dimensional core transient simulations for rod movements, the key parameters of DCRM method are determined to implement into the Direct Digital Reactivity Computer System (DDRCS). A total of 9 bank worths of two KSNP plants were measured to compare with the worths of the conventional rod worth measurement method. The results show that the average error of DCRM method is nearly the same as the conventional Rod Swap and Boron Dilution Method but lower standard deviation. It takes about twenty minutes from the beginning of rod movement to final estimation of the integral static worth of a control bank. (authors)

  8. Standard test methods for determining average grain size using semiautomatic and automatic image analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 These test methods are used to determine grain size from measurements of grain intercept lengths, intercept counts, intersection counts, grain boundary length, and grain areas. 1.2 These measurements are made with a semiautomatic digitizing tablet or by automatic image analysis using an image of the grain structure produced by a microscope. 1.3 These test methods are applicable to any type of grain structure or grain size distribution as long as the grain boundaries can be clearly delineated by etching and subsequent image processing, if necessary. 1.4 These test methods are applicable to measurement of other grain-like microstructures, such as cell structures. 1.5 This standard deals only with the recommended test methods and nothing in it should be construed as defining or establishing limits of acceptability or fitness for purpose of the materials tested. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user ...

  9. Standard test method for radiochemical determination of uranium isotopes in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of alpha-emitting uranium isotopes in soil. This test method describes one acceptable approach to the determination of uranium isotopes in soil. 1.2 The test method is designed to analyze 10 g of soil; however, the sample size may be varied to 50 g depending on the activity level. This test method may not be able to completely dissolve all forms of uranium in the soil matrix. Studies have indicated that the use of hydrofluoric acid to dissolve soil has resulted in lower values than results using total dissolution by fusion. 1.3 The lower limit of detection is dependent on count time, sample size, detector, background, and tracer yield. The chemical yield averaged 78 % in a single laboratory evaluation, and 66 % in an interlaboratory collaborative study. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, ass...

  10. Standardized phenology monitoring methods to track plant and animal activity for science and resource management applications

    Science.gov (United States)

    Denny, Ellen G.; Gerst, Katharine L.; Miller-Rushing, Abraham J.; Tierney, Geraldine L.; Crimmins, Theresa M.; Enquist, Carolyn A.F.; Guertin, Patricia; Rosemartin, Alyssa H.; Schwartz, Mark D.; Thomas, Kathryn A.; Weltzin, Jake F.

    2014-01-01

    Phenology offers critical insights into the responses of species to climate change; shifts in species’ phenologies can result in disruptions to the ecosystem processes and services upon which human livelihood depends. To better detect such shifts, scientists need long-term phenological records covering many taxa and across a broad geographic distribution. To date, phenological observation efforts across the USA have been geographically limited and have used different methods, making comparisons across sites and species difficult. To facilitate coordinated cross-site, cross-species, and geographically extensive phenological monitoring across the nation, the USA National Phenology Network has developed in situ monitoring protocols standardized across taxonomic groups and ecosystem types for terrestrial, freshwater, and marine plant and animal taxa. The protocols include elements that allow enhanced detection and description of phenological responses, including assessment of phenological “status”, or the ability to track presence–absence of a particular phenophase, as well as standards for documenting the degree to which phenological activity is expressed in terms of intensity or abundance. Data collected by this method can be integrated with historical phenology data sets, enabling the development of databases for spatial and temporal assessment of changes in status and trends of disparate organisms. To build a common, spatially, and temporally extensive multi-taxa phenological data set available for a variety of research and science applications, we encourage scientists, resources managers, and others conducting ecological monitoring or research to consider utilization of these standardized protocols for tracking the seasonal activity of plants and animals.

  11. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reactions 46Ti(n,p) 46Sc + 47Ti(n, np)46Sc. Note 1—Since the cross section for the (n,np) reaction is relatively small for energies less than 12 MeV and is not easily distinguished from that of the (n,p) reaction, this test method will refer to the (n,p) reaction only. 1.2 The reaction is useful for measuring neutrons with energies above approximately 4.4 MeV and for irradiation times up to about 250 days (for longer irradiations, see Practice E 261). 1.3 With suitable techniques, fission-neutron fluence rates above 109 cm–2·s–1 can be determined. However, in the presence of a high thermal-neutron fluence rate, 46Sc depletion should be investigated. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all...

  12. Standard Test Method for Effects of Cleaning and Chemical Maintenance Materials on Painted Aircraft Surfaces

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers determination of the effects of cleaning solutions and liquid cleaner concentrates on painted aircraft surfaces (Note 1). Streaking, discoloration, and blistering may be determined visually. Softening is determined with a series of specially prepared pencils wherein determination of the softest pencil to rupture the paint film is made. Note 1—This test method is applicable to any paint film that is exposed to cleaning materials. MIL-PRF-85285 has been selected as a basic example. When other paint finishes are used, refer to the applicable material specification for panel preparation and system curing prior to testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user ...

  13. Preparation and LSC standardization of ''89 Sr (DNP) using the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Arcos Merino, J.M. Los; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting samples of the strontium DNP complex, labelled with ''89 Sr, is described. The chemical quench, the counting stability and spectral evolution of this compound is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-naphthalene, HiSafe II, Ultima-Gold and Instagel. The liquid scintillation standardization of ''89Sr-DNP by the CIEMAT/NIST method, using Hisafe II and Ultima-Gold scintillators, has been carried out. The discrepancies between experimental and computed efficiencies are lower than 0.38% and 0.48%, respectively. The solution has been standardized in terms of activity concentration to an overall uncertainty of 0.38%. (Author)

  14. Preparation and LSC Standardization of ''89Sr (DNP) Using the CIEMAT/NIST Method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos Merino, J. M.; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting samples of the strontium DNP complex, labelled with ''89Sr, is described, the chemical quench, the counting stability and spectral evolution of this compound is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-naphthalene, HiSafe II, Ultima- Gold and Instagel. The liquid scintillation standardization of 89Sr-DNP by the CIEMAT/NIST method, using HiSafe II and Ultima-Gold scintillators, has been carried out. The discrepancies between experimental and computed efficiencies are lower than 0.38% and 0.48%, respectively. The solution has been standardized in terms of activity concentration to an overall uncertainty of 0,38%. (Author) 10 refs

  15. Paediatric rehabilitation treatment standards: a method for quality assurance in Germany

    Directory of Open Access Journals (Sweden)

    Jutta Ahnert

    2014-07-01

    Full Text Available Over the last few years, the German Pension Insurance has implemented a new method of quality assurance for inpatient rehabilitation of children and adolescents diagnosed with bronchial asthma, obesity, or atopic dermatitis: the so-called rehabilitation treatment standards (RTS. They aim at promoting a comprehensive and evidence-based care in rehabilitation. Furthermore, they are intended to make the therapeutic processes in medical rehabilitation as well as potential deficits more transparent. The development of RTS was composed of five phases during which current scientific evidence, expert knowledge, and patient expectations were included. Their core element is the specification of evidence-based treatment modules that describe a good rehabilitation standard for children diagnosed with bronchial asthma, obesity, or atopic dermatitis. Opportunities and limitations of the RTS as a tool for quality assurance are discussed.

  16. Standard Test Method for Stress-Corrosion of Titanium Alloys by Aircraft Engine Cleaning Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method establishes a test procedure for determining the propensity of aircraft turbine engine cleaning and maintenance materials for causing stress corrosion cracking of titanium alloy parts. 1.2 The evaluation is conducted on representative titanium alloys by determining the effect of contact with cleaning and maintenance materials on tendency of prestressed titanium alloys to crack when subsequently heated to elevated temperatures. 1.3 Test conditions are based upon manufacturer's maximum recommended operating solution concentration. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see and .

  17. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Aluminum

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers procedures measuring reaction rates by the activation reaction 27Al(n,α)24Na. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 6.5 MeV and for irradiation times up to about 2 days (for longer irradiations, see Practice E261). 1.3 With suitable techniques, fission-neutron fluence rates above 106 cm−2·s−1 can be determined. 1.4 Detailed procedures for other fast neutron detectors are referenced in Practice E261. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Standard test method for 238Pu isotopic abundance by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method covers the use of alpha spectrometry for determining the 238Pu isotopic abundance in plutonium samples. It is particularly useful for samples in which the 238Pu content is less than 1 % of the total plutonium content. For such samples, mass spectrometric results are less reliable than those from alpha spectrometry because of interference from any 238U isobar remaining after ion exchange. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Standard test method for linear-elastic plane-strain fracture toughness KIc of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of fracture toughness (KIc) of metallic materials under predominantly linear-elastic, plane-strain conditions using fatigue precracked specimens having a thickness of 1.6 mm (0.063 in.) or greater subjected to slowly, or in special (elective) cases rapidly, increasing crack-displacement force. Details of test apparatus, specimen configuration, and experimental procedure are given in the Annexes. Note 1—Plane-strain fracture toughness tests of thinner materials that are sufficiently brittle (see 7.1) can be made using other types of specimens (1). There is no standard test method for such thin materials. 1.2 This test method is divided into two parts. The first part gives general recommendations and requirements for KIc testing. The second part consists of Annexes that give specific information on displacement gage and loading fixture design, special requirements for individual specimen configurations, and detailed procedures for fatigue precracking. Additional a...

  20. Standard criteria and methods to assess the reclamation of native vegetation on mined land

    International Nuclear Information System (INIS)

    Humphries, R.N.; Benyon, P.R.

    1999-01-01

    There is currently much interest in the re-establishment of native (semi-natural) vegetation in mineral workings in the UK. It is expected that future planning consents will have conditions attached which require evidence that the proposed communities have been achieved. At present there is no standard approach. This paper describes a formal sample based method which enables assessment of plant community, species richness and species of particular interest at any point in time and their course of development. The method is illustrated by use of data collected for sown grassland on a restored opencast coal site in South Wales. Further development work is likely to be necessary and comparison with other recently recommended methods is suggested

  1. Standard test method for determination of "microwave safe for reheating" for ceramicware

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method determines the suitability of ceramicware for use in microwave re-heating applications. Microwave ovens are mainly used for reheating and defrosting frozen foods. Severe thermal conditions can occur while reheating foods. Typical reheating of foods requires one to five min. in the microwave at the highest power settings. Longer periods than five minutes are considered cooking. Cooking test methods and standards are not addressed in this test method. Most ceramicware is minimally absorbing of the microwave energy and will not heat up significantly. Unfortunately there are some products that absorb microwave energy to a greater extent and can become very hot in the microwave and pose a serious hazard. Additionally, the nature of microwave heating introduces radiation in a non-uniform manner producing temperature differentials in the food being cooked as well as the ceramic container holding it. The differential may become great enough to thermal shock the ware and create dangerous condition...

  2. Standard test method for linear-elastic plane-strain fracture toughness KIc of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2013-01-01

    1.1 This test method covers the determination of fracture toughness (KIc) of metallic materials under predominantly linear-elastic, plane-strain conditions using fatigue precracked specimens having a thickness of 1.6 mm (0.063 in.) or greater subjected to slowly, or in special (elective) cases rapidly, increasing crack-displacement force. Details of test apparatus, specimen configuration, and experimental procedure are given in the Annexes. Note 1—Plane-strain fracture toughness tests of thinner materials that are sufficiently brittle (see 7.1) can be made using other types of specimens (1). There is no standard test method for such thin materials. 1.2 This test method is divided into two parts. The first part gives general recommendations and requirements for KIc testing. The second part consists of Annexes that give specific information on displacement gage and loading fixture design, special requirements for individual specimen configurations, and detailed procedures for fatigue precracking. Additional a...

  3. A novel standardized bone model for thermal evaluation of bone osteotomies with various irrigation methods.

    Science.gov (United States)

    Strbac, Georg D; Giannis, Katharina; Unger, Ewald; Mittlböck, Martina; Watzek, Georg; Zechner, Werner

    2014-05-01

    Based on a novel standardized bovine specimen, the aim of this study was to investigate thermal effects of different irrigation methods during intermittent and graduated drilling. Temperature changes during implant osteotomies (n = 320) of 10 and 16 mm drilling depths with various irrigation methods were investigated on manufactured uniform bone samples providing homogenous cortical and cancellous areas and analogous thermal conductivity comparable to human bone. Automated sequences were performed with surgical twist drills of 2 mm ∅ and conical drills of 3.5, 4.3 and 5 mm ∅. Real-time recording of temperature increase was done using two custom-built multichannel thermoprobes with 14 temperature sensors at a predefined distance of 1 and 2 mm to the final osteotomy. The effects of drilling depth, drilling diameter and irrigation methods on temperature changes were investigated by a linear mixed model. Using this uniform bone specimen, the greatest temperature rise was observed without any coolant supply with 29.87°C, followed by external with 28.47°C and then internal with 25.86°C and combined irrigation with 25.68°C. Significant differences (P ≤ 0.0156) between drill depths of 10 vs. 16 mm could be observed with all irrigation methods evaluated. With each of the irrigation methods, significantly higher temperature changes (P irrigation showed significantly higher temperatures (P irrigation, respectively. Significantly lower temperatures (P irrigation for the use of conical drills with various diameters and drilling depths. This fully standardized bone model provides optimized comparability for the evaluation of bone osteotomies and resulting temperature changes. As regards the efficiency of the various irrigation methods, it could be demonstrated that internal and combined irrigation appears to be more beneficial than external irrigation. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  4. A method to standardize gait and balance variables for gait velocity.

    Science.gov (United States)

    van Iersel, Marianne B; Olde Rikkert, Marcel G M; Borm, George F

    2007-07-01

    Many gait and balance variables depend on gait velocity, which seriously hinders the interpretation of gait and balance data derived from walks at different velocities. However, as far as we know there is no widely accepted method to correct for effects of gait velocity on other gait and balance measures. We developed a simple statistical method to obtain gait and balance variables for each participant that are independent of gait velocity. The first step of our standardization method was the transformation of the gait and balance data to obtain a normal distribution and decrease the influence of outliers. Thereafter, we constructed a formula, based on regression analysis that described how these data varied with gait velocity in each participant during walking without an additional task. Last, this formula was used to standardize the gait and balance data for the effect of gait velocity for each individual participant. As example we present the analysis of mediolateral displacements of the trunk in fit elderly people during walking with and without a dual task.

  5. Improvement of Cost Calculation in Constructions – Application of the Standard Cost Method

    Directory of Open Access Journals (Sweden)

    Adela Breuer

    2010-12-01

    Full Text Available Grace to the analysis of several commercial companies effectively performed “on the field”, we could remark the necessity to change the method of cost calculation, our motivation being related to the simplification of calculations and the reduction of the labour volume, but especially the necessity to know in due time the deviations occurred as well as the causes having led to their apparition. The importance of knowing the deviations in due time results from the very basic characteristics of the constructions execution, i.e. the performance of works during several budgetary years, which leads to the modifications of prices and materials, the introduction of new technologies, and to the performance of open air activities, making the execution of constructions works be influenced by the atmospheric condition. But the most important aspect of knowing the deviations is the correct determination of expenses and their inscribing in the corresponding period, in view of determining the result of the budgetary year. Our proposal for the enhancement of the method of cost calculation in constructions is the application of the standard cost method in the variant “single standard cost”.

  6. Standard Test Method for Oxyacetylene Ablation Testing of Thermal Insulation Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the screening of ablative materials to determine the relative thermal insulation effectiveness when tested as a flat panel in an environment of a steady flow of hot gas provided by an oxyacetylene burner. 1.2 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  7. Reducing the risk of failure: Software Quality assurance standards and methods

    International Nuclear Information System (INIS)

    Elphick, J.; Cope, H.

    1992-01-01

    An effective Software Quality Assurance (SQA) program provides an overall approach to software engineering and the establishment of proven methods for the production of reliable software. And, in the authors experience, the overall costs for the software life are diminished with the application of quality methods. In their experience, the issues for implementing quality standards and practices are many. This paper addresses those issues as well as the lessons learned from developing and implementing a number of software quality assurance programs. Their experience includes the development and implementation of their own NRC accepted SQA program and an SQA program for an engineering software developer, as well as developing SQA procedures, standards, and methods for utilities, medical and commercial clients. Some of the issues addressed in this paper are: setting goals and defining quality; applying the software life cycle; addressing organizational issues; providing flexibility and increasing productivity; producing effective documentation; maintaining quality records; Imposing software configuration management; conducting reviews, audits, and controls; verification and validation; and controlling software procurement

  8. Standardization of a method to study angiogenesis in a mouse model

    Directory of Open Access Journals (Sweden)

    DAVID FEDER

    2013-01-01

    Full Text Available In the adult organism, angiogenesis is restricted to a few physiological conditions. On the other hand, uncontrolled angiogenesis have often been associated to angiogenesis-dependent pathologies. A variety of animal models have been described to provide more quantitative analysis of in vivo angiogenesis and to characterize pro- and antiangiogenic molecules. However, it is still necessary to establish a quantitative, reproducible and specific method for studies of angiogenesis factors and inhibitors. This work aimed to standardize a method for the study of angiogenesis and to investigate the effects of thalidomide on angiogenesis. Sponges of 0.5 x 0.5 x 0.5 cm were implanted in the back of mice groups, control and experimental (thalidomide 200 mg/K/day by gavage. After seven days, the sponges were removed. The dosage of hemoglobin in sponge and in circulation was performed and the ratio between the values was tested using nonparametric Mann-Whitney test. Results have shown that sponge-induced angiogenesis quantitated by ratio between hemoglobin content in serum and in sponge is a helpful model for in vivo studies on angiogenesis. Moreover, it was observed that sponge-induced angiogenesis can be suppressed by thalidomide, corroborating to the validity of the standardized method.

  9. Standard method of macroetch testing steel bars, billets, blooms, and forgings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 Macroetching, which is the etching of specimens for macrostructural examination at low magnifications, is a frequently used technique for evaluating steel products such as bars, billets, blooms, and forgings. 1.2 Included in this method is a procedure for rating steel specimens by a graded series of photographs showing the incidence of certain conditions. The method is limited in application to bars, billets, blooms, and forgings of carbon and low alloy steels. 1.3 A number of different etching reagents may be used depending upon the type of examination to be made. Steels react differently to etching reagents because of variations in chemical composition, method of manufacture, heat treatment and many other variables. Establishment of general standards for acceptance or rejection for all conditions is impractical as some conditions must be considered relative to the part in which it occurs. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is ...

  10. Standard test methods for notched bar impact testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods describe notched-bar impact testing of metallic materials by the Charpy (simple-beam) test and the Izod (cantilever-beam) test. They give the requirements for: test specimens, test procedures, test reports, test machines (see Annex A1) verifying Charpy impact machines (see Annex A2), optional test specimen configurations (see Annex A3), precracking Charpy V-notch specimens (see Annex A4), designation of test specimen orientation (see Annex A5), and determining the percent of shear fracture on the surface of broken impact specimens (see Annex A6). In addition, information is provided on the significance of notched-bar impact testing (see Appendix X2), methods of measuring the center of strike (see Appendix X2). 1.2 These test methods do not address the problems associated with impact testing at temperatures below -196 C (-320 F, 77 K). 1.3 The values stated in SI units are to be regarded as the standard. Inch-pound units are provided for information only. This standard does not purpor...

  11. Multimodal nonlinear microscopy: A powerful label-free method for supporting standard diagnostics on biological tissues

    Directory of Open Access Journals (Sweden)

    Riccardo Cicchi

    2014-09-01

    Full Text Available The large use of nonlinear laser scanning microscopy in the past decade paved the way for potential clinical application of this imaging technique. Modern nonlinear microscopy techniques offer promising label-free solutions to improve diagnostic performances on tissues. In particular, the combination of multiple nonlinear imaging techniques in the same microscope allows integrating morphological with functional information in a morpho-functional scheme. Such approach provides a high-resolution label-free alternative to both histological and immunohistochemical examination of tissues and is becoming increasingly popular among the clinical community. Nevertheless, several technical improvements, including automatic scanning and image analysis, are required before the technique represents a standard diagnostic method. In this review paper, we highlight the capabilities of multimodal nonlinear microscopy for tissue imaging, by providing various examples on colon, arterial and skin tissues. The comparison between images acquired using multimodal nonlinear microscopy and histology shows a good agreement between the two methods. The results demonstrate that multimodal nonlinear microscopy is a powerful label-free alternative to standard histopathological methods and has the potential to find a stable place in the clinical setting in the near future.

  12. Standard method for the determination of activity concentration of 90Sr in water

    International Nuclear Information System (INIS)

    1987-01-01

    The subject of the standard is the determination of the radioactive concentration of 90 Sr in surface waters, in ground water and in drinking water, by measuring the radioactivity of the daughter isotope 90 Y that was previously separated by a selective radiochemical method. Yttrium ions are extracted from alkaline earth metal cations by tributil-phosphate equilibrated with concentrated nitric acid. The ions are then reextracted into distilled water and precipitated in the form of yttrium-oxalate. Radioactivity of the precipitate is determined based on the measurement of the β-disintegration rate using a low-background nuclear instrument. (V.N.)

  13. Assessing postoperative reduction following acetabular fracture surgery: A standardized digital CT-based method.

    Science.gov (United States)

    Verbeek, Diederik O; van der List, Jelle P; Moloney, Gele B; Wellman, David S; Helfet, David L

    2018-02-23

    Quality of reduction following acetabular fracture surgery is an important predictor for clinical outcome. Computed tomography likely superior to plain pelvic radiography for assessment of postoperative reduction but interobserver reliability may be limited in the absence of a widely adopted technique. We describe a standardized digital CT-based method for measuring residual (gap and step) displacement on CT following acetabular fracture surgery. In a selection of patients, we determined the interobserver reliability for measuring displacement and grading quality of reduction on postoperative pelvic radiography and CT with and without the use of this novel technique.

  14. Accurate determination of arsenic in arsenobetaine standard solutions of BCR-626 and NMIJ CRM 7901-a by neutron activation analysis coupled with internal standard method.

    Science.gov (United States)

    Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki

    2010-09-15

    Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  15. The application of the k0-standardization method at the TRIGA Mark II reactor, Ljubljana, Slovenia

    International Nuclear Information System (INIS)

    Jacimovic, Radojko; Benedik, Ljudmila; Stegnar, Peter; Smodis, Borut

    2002-01-01

    The k 0 -standardization method of neutron activation analysis (k 0 -NAA) was launched in the 1970s and since then continuously developed. Nowadays, k 0 -NAA became widespread as a practical analytical tool used to analyse different sample matrices. At the Jozef Stefan Institute (IJS), the KAYZERO/SOLCOI software package has been introduced for data processing after extensive testing and comparison with other available programs. In the process of validation of the software a suite of natural matrix reference materials (RMs) were used. Five certified reference materials (CRMs) from the Institute for Reference Materials and Measurements (IRMM), two standard reference materials (SRMs) from the National Institute of Standards and Technology (NIST), three RMs from the International Atomic Energy Agency (IAEA) and one RM from IJS were analysed. Altogether, results for ten elements in inorganic matrices and twenty-one elements in organic matrices, obtained by k 0 -instrumental neutron activation analysis (k 0 -INAA), were compared to certified values. The results obtained show good agreement with certified or assigned values except for Fe and U in inorganic matrices, and Al and Cr in organic matrices. (author)

  16. Dissemination of the National Standard of Mass from INACAL using the gauss Markov method by generalized least squares

    OpenAIRE

    Taipe, Donny

    2017-01-01

    This article sustains the transfer of the national standard of mass (KP1) of INACAL to two reference standards ‘Weight 1’, ‘Weight 2’ and also KP2 (as witnessed mass standard and with known error). The dissemination was done using the Gauss Markov method by Generalized Least Squares. The uncertainty calculation was performed using Univariate Gaussian Distribution and Multivariate Gaussian Distribution; the latter was developed with the Monte Carlo method using a programming language called 'R...

  17. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 7, 0.07 Conveying

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    System information is given for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards and inspection methods are presented for elevators and special conveyors.

  18. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 3, 0.03 Superstructure

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented on asset determinant factor/CAS profile codes/CAS cost process; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for beams; pre-engineered building systems; floors; roof structure; stairs; and fireproofing.

  19. Developing a Standard Method of Test for Packaged, Solid-Desiccant Based Dehumidification Systems

    International Nuclear Information System (INIS)

    Sand, J.R.

    2001-01-01

    A draft Method of Test (MOT) has been proposed for packaged, air-to-air, desiccant-based dehumidifier systems that incorporate a thermally-regenerated desiccant material for dehumidification. This MOT is intended to function as the ''system'' testing and rating compliment to the desiccant ''component'' (desiccant wheels and/or cassettes) MOT (ASHRAE 1998) and rating standard (ARI 1998) already adopted by industry. This draft standard applies to ''packaged systems'' that: Use desiccants for dehumidification of conditioned air for buildings; Use heated air for regeneration of the desiccant material; Include fans for moving process and regeneration air; May include other system components for filtering, pre-cooling, post-cooling, or heating conditioned air; and May include other components for humidification of conditioned air. The proposed draft applies to four different system operating modes depending on whether outdoor or indoor air is used for process air and regeneration air streams . Only the ''ventilation'' mode which uses outdoor air for both process and regeneration inlets is evaluated in this paper. Performance of the dehumidification system is presented in terms that would be most familiar and useful to designers of building HVAC systems to facilitate integration of desiccant equipment with more conventional hardware. Parametric performance results from a modified, commercial desiccant dehumidifier undergoing laboratory testing were used as data input to evaluate the draft standard. Performance results calculated from this experimental input, results from an error-checking/heat-balance verification test built into the standard, and estimated comparisons between desiccant and similarly performing conventional dehumidification equipment are calculated and presented. Some variations in test procedures are suggested to aid in analytical assessment of individual component performance

  20. Standardized patients' preferences for pharmacist interactive communication style: A mixed method approach.

    Science.gov (United States)

    Guirguis, Lisa M; Nusair, Mohammad B

    2016-01-01

    Interactive communication approaches may help to shift pharmacy practice toward more patient-centered care. One example of such an approach is the 3 prime questions (3PQs). Patients' preferences for pharmacists' interactive communication styles were not identified in the literature. The purpose of this paper was to explore standardized patient (SP) preferences, satisfaction, and perceptions of pharmacists' communication style and changes in pharmacist to standardized patient talk-time ratio. Mixed methods, before and after evaluation. SPs were hired from the University of Alberta's Standardized Patient Program, Canada. Twelve SPs and 10 pharmacists. SPs were video recorded interacting with the same pharmacists before and after pharmacist training on the 3PQs. SPs participated in an open-ended interview using stimulated recall on videos of their pharmacist encounters. Explore SP preferences, satisfaction, and perceptions of pharmacists' communication style, in addition to changes in pharmacist to standardized patient talk-time ratio before and after the intervention Generally SPs were satisfied with pharmacists' interactive communication style post training. Qualitative themes varied with SPs' preference for an interactive approach (58%, i.e., Conversation with Equals, Double Check, and Manageable Information) or traditional approach (33%, i.e., Expected Information, Shouldn't the Pharmacist Know, and Feels Uncomfortable) and improvements in item scores varied by type of prescription. Pharmacists' use of the 3PQs increased patient talk time for scenarios with new chronic and acute medication, though pharmacists still dominated the conversation. Just over half of SPs preferred an interactive communication style, although a third of SPs preferred a communication style that focused on information provision. Patients had more time to talk in some interactive encounters. Pharmacists may need to be aware of patient expectations when using the 3PQs. Copyright © 2016

  1. Application of Scharer's quantitative method for the determination of residual alkaline phosphatase activity in standard Minas

    Directory of Open Access Journals (Sweden)

    C.F. Soares

    2013-08-01

    Full Text Available Milk pasteurization is a critical issue in the dairy industry, and failures in this process can affect final product safety. Scharer's enzymatic method is still traditionally used to verify pasteurization efficiency compliance, and it is based on screening for residual alkaline phosphatase in milk. Although several methods are used to quantify enzymatic activity to assess milk pasteurization efficiency, there is a small amount of published data regarding the use of these methods to quantify alkaline phosphatase in cheese. In this study, the Scharer's modified method was used to determine the levels of residual alkaline phosphatase in standard minas cheese, before and after 20 days of ripening. The cheeses were made using raw or pasteurized milk with the addition of different concentrations of raw milk (0; 0.05%; 0.10%; 0.20%; and 0.50%. In the fresh cheese samples, the method showed a sensitivity of only 0.50% with the addition of raw milk to the pasteurized milk used to make cheese. In addition, levels of up 0.20% of raw milk in pasteurized milk, the concentrations of phenol was inferior to 1μg phenol/g of dairy product which is the preconized indicator value for adequate pasteurization.

  2. The PolyMAX Frequency-Domain Method: A New Standard for Modal Parameter Estimation?

    Directory of Open Access Journals (Sweden)

    Bart Peeters

    2004-01-01

    Full Text Available Recently, a new non-iterative frequency-domain parameter estimation method was proposed. It is based on a (weighted least-squares approach and uses multiple-input-multiple-output frequency response functions as primary data. This so-called “PolyMAX” or polyreference least-squares complex frequency-domain method can be implemented in a very similar way as the industry standard polyreference (time-domain least-squares complex exponential method: in a first step a stabilisation diagram is constructed containing frequency, damping and participation information. Next, the mode shapes are found in a second least-squares step, based on the user selection of stable poles. One of the specific advantages of the technique lies in the very stable identification of the system poles and participation factors as a function of the specified system order, leading to easy-to-interpret stabilisation diagrams. This implies a potential for automating the method and to apply it to “difficult” estimation cases such as high-order and/or highly damped systems with large modal overlap. Some real-life automotive and aerospace case studies are discussed. PolyMAX is compared with classical methods concerning stability, accuracy of the estimated modal parameters and quality of the frequency response function synthesis.

  3. Standard Test Method for Measuring Heat Flux Using Surface-Mounted One-Dimensional Flat Gages

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes the measurement of the net heat flux normal to a surface using flat gages mounted onto the surface. Conduction heat flux is not the focus of this standard. Conduction applications related to insulation materials are covered by Test Method C 518 and Practices C 1041 and C 1046. The sensors covered by this test method all use a measurement of the temperature difference between two parallel planes normal to the surface to determine the heat that is exchanged to or from the surface in keeping with Fourier’s Law. The gages operate by the same principles for heat transfer in either direction. 1.2 This test method is quite broad in its field of application, size and construction. Different sensor types are described in detail in later sections as examples of the general method for measuring heat flux from the temperature gradient normal to a surface (1). Applications include both radiation and convection heat transfer. The gages have broad application from aerospace to biomedical en...

  4. Accuracy of standard measures of family planning service quality: findings from the simulated client method.

    Science.gov (United States)

    Tumlinson, Katherine; Speizer, Ilene S; Curtis, Siân L; Pence, Brian W

    2014-12-01

    In the field of international family planning, quality of care as a reproductive right is widely endorsed, yet we lack validated data-collection instruments that can accurately assess quality in terms of its public health importance. This study, conducted within 19 public and private facilities in Kisumu, Kenya, used the simulated client method to test the validity of three standard data-collection instruments used in large-scale facility surveys: provider interviews, client interviews, and observation of client-provider interactions. Results found low specificity and low positive predictive values in each of the three instruments for a number of quality indicators, suggesting that the quality of care provided may be overestimated by traditional methods of measurement. Revised approaches to measuring family planning service quality may be needed to ensure accurate assessment of programs and to better inform quality-improvement interventions. © 2014 The Population Council, Inc.

  5. Echinacea standardization: analytical methods for phenolic compounds and typical levels in medicinal species.

    Science.gov (United States)

    Perry, N B; Burgess, E J; Glennie, V L

    2001-04-01

    A proposed standard extraction and HPLC analysis method has been used to measure typical levels of various phenolic compounds in the medicinally used Echinacea species. Chicoric acid was the main phenolic in E. purpurea roots (mean 2.27% summer, 1.68% autumn) and tops (2.02% summer, 0.52% autumn), and echinacoside was the main phenolic in E. angustifolia (1.04%) and E. pallida roots (0.34%). Caftaric acid was the other main phenolic compound in E. purpurea roots (0.40% summer, 0.35% autumn) and tops (0.82% summer, 0.18% autumn), and cynarin was a characteristic component of E. angustifolia roots (0.12%). Enzymatic browning during extraction could reduce the measured levels of phenolic compounds by >50%. Colorimetric analyses for total phenolics correlated well with the HPLC results for E. purpurea and E. angustifolia, but the colorimetric method gave higher values.

  6. Determine equilibrium dissociation constant of drug-membrane receptor affinity using the cell membrane chromatography relative standard method.

    Science.gov (United States)

    Ma, Weina; Yang, Liu; Lv, Yanni; Fu, Jia; Zhang, Yanmin; He, Langchong

    2017-06-23

    The equilibrium dissociation constant (K D ) of drug-membrane receptor affinity is the basic parameter that reflects the strength of interaction. The cell membrane chromatography (CMC) method is an effective technique to study the characteristics of drug-membrane receptor affinity. In this study, the K D value of CMC relative standard method for the determination of drug-membrane receptor affinity was established to analyze the relative K D values of drugs binding to the membrane receptors (Epidermal growth factor receptor and angiotensin II receptor). The K D values obtained by the CMC relative standard method had a strong correlation with those obtained by the frontal analysis method. Additionally, the K D values obtained by CMC relative standard method correlated with pharmacological activity of the drug being evaluated. The CMC relative standard method is a convenient and effective method to evaluate drug-membrane receptor affinity. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Standard test method for measuring waste glass or glass ceramic durability by vapor hydration test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 The vapor hydration test method can be used to study the corrosion of a waste forms such as glasses and glass ceramics upon exposure to water vapor at elevated temperatures. In addition, the alteration phases that form can be used as indicators of those phases that may form under repository conditions. These tests; which allow altering of glass at high surface area to solution volume ratio; provide useful information regarding the alteration phases that are formed, the disposition of radioactive and hazardous components, and the alteration kinetics under the specific test conditions. This information may be used in performance assessment (McGrail et al, 2002 (1) for example). 1.2 This test method must be performed in accordance with all quality assurance requirements for acceptance of the data. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice...

  8. Standard Test Method for Impact Resistance of Monolithic Polycarbonate Sheet by Means of a Falling Weight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers the determination of the energy required to initiate failure in monolithic polycarbonate sheet material under specified conditions of impact using a free falling weight. 1.2 Two specimen types are defined as follows: 1.2.1 Type A consists of a flat plate test specimen and employs a clamped ring support. 1.2.2 Type B consists of a simply supported three-point loaded beam specimen (Fig. 1) and is recommended for use with material which can not be failed using the Type A specimen. For a maximum drop height of 6.096 m (20 ft) and a maximum drop weight of 22.68 kg (50 lb), virgin polycarbonate greater than 12.70 mm (1/2 in.) thick will probably require use of the Type B specimen. Note 1 - See also ASTM Methods: D 1709, D 2444 and D 3029. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of reg...

  9. Implementation of a standardized out-of-hospital management method for Parkinson dysphagia

    Directory of Open Access Journals (Sweden)

    Hongying Wei

    Full Text Available Summary Objective: Our objective is to explore the effectiveness and feasibility of establishing a swallowing management clinic to implement out-of-hospital management for Parkinson disease (PD patients with dysphagia. Method: Two-hundred seventeen (217 voluntary PD patients with dysphagia in a PD outpatient clinic were divided into a control group with 100 people, and an experimental group with 117 people. The control group was given dysphagia rehabilitation guidance. The experimental group was presented with the standardized out-of-hospital management method as overall management and information and education materials. Rehabilitation efficiency and incidence rate of dysphagia, as well as relevant complications of both groups were compared after a 6-month intervention. Results: Rehabilitation efficiency and the incidence rate of dysphagia including relevant complications of patients treated with the standardized out-of-hospital management were compared with those seen in the control group. The differences have distinct statistics meaning (p<0.01. Conclusion: Establishing a swallowing management protocol for outpatient setting can effectively help the recovery of the function of swallowing, reduce the incidence rate of dysphagia complications and improve the quality of life in patients with PD.

  10. Japan Explosives Society Standard. 5. Measuring method for propellant; Kayaku gakkai kikaku. 5. Puroperanto keisoku hoho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-30

    This paper states a standard measuring method for propellants as a Standard of Japan Explosives Society. A propellant is a high-energy substance used as a rocket motor propellant and as a gunpowder for guns. For its practical application, its physical and chemical properties must be identified, and ignition and combustion phenomena must be understood fully. Such characteristics are also demanded that predetermined performance is maintained even after having been stored for an extended period of time, and the material will not decompose, deteriorate, or ignite spontaneously. Also, when the propellant`s energy is discharged by a rocket motor and a gun, the propellant must burn at a predetermined velocity, and cause no abnormal ignition, vibratory combustion and erosive combustion. Physical and chemical property values of propellants vary largely with materials constituting the propellants and their mixing ratio. Property requirements also vary depending on practical use conditions. Therefore, this paper describes a measuring method required to derive basic properties of the propellants, so that data derived from the measurement may be used commonly by engineers.

  11. Standardizing chromatin research: a simple and universal method for ChIP-seq.

    Science.gov (United States)

    Arrigoni, Laura; Richter, Andreas S; Betancourt, Emily; Bruder, Kerstin; Diehl, Sarah; Manke, Thomas; Bönisch, Ulrike

    2016-04-20

    Chromatin immunoprecipitation followed by next generation sequencing (ChIP-seq) is a key technique in chromatin research. Although heavily applied, existing ChIP-seq protocols are often highly fine-tuned workflows, optimized for specific experimental requirements. Especially the initial steps of ChIP-seq, particularly chromatin shearing, are deemed to be exceedingly cell-type-specific, thus impeding any protocol standardization efforts. Here we demonstrate that harmonization of ChIP-seq workflows across cell types and conditions is possible when obtaining chromatin from properly isolated nuclei. We established an ultrasound-based nuclei extraction method (NEXSON: Nuclei EXtraction by SONication) that is highly effective across various organisms, cell types and cell numbers. The described method has the potential to replace complex cell-type-specific, but largely ineffective, nuclei isolation protocols. By including NEXSON in ChIP-seq workflows, we completely eliminate the need for extensive optimization and sample-dependent adjustments. Apart from this significant simplification, our approach also provides the basis for a fully standardized ChIP-seq and yields highly reproducible transcription factor and histone modifications maps for a wide range of different cell types. Even small cell numbers (∼10,000 cells per ChIP) can be easily processed without application of modified chromatin or library preparation protocols. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  12. Standardization of 59Fe 4πβ(LS)-γcoincidence counting with digital sampling method

    International Nuclear Information System (INIS)

    Agusbudiman, A.; Lee, K. B.; Lee, J. M.; Park, T. S.

    2014-01-01

    The radionuclide 59Fe decays with a half-life of 44.494(12) days, by several beta minus emission to the ground state and to four excited states of 59 Co, mainly to the 1099 keV and 1291 keV (Bé et al., 2004). The activity of 59 Fe was measured by 4 πβ(LS)-γ coincidence counting method with digital sampling technique. A gamma spectrometry analysis was also conducted to check the impurities of the source. As comparison, the activity were also measured by using the 4πβ(PC)-γ coincidence counting system and 4πβ (LS)-γ anti-coincidence method. The radionuclide 59Fe has been standardized using the 4πβ(LS)-γcoincidence counting with digital sampling method. The result was in a good agreement with the result from 4πβ(PC)-γ coincidence counting and the 4πβ(LS)-γ anti-coincidence method

  13. Method development and validation for dieckol in the standardization of phlorotannin preparations

    Directory of Open Access Journals (Sweden)

    Jiyoung Kim

    2016-03-01

    Full Text Available Abstract Phlorotannins are reported to have diverse biological properties. However, no analytical methods for the standardization of phlorotannin preparations have been reported. Herein, we developed and validated an analytical method for the determination of dieckol in phlorotannin extracts (PRT using high-performance liquid chromatography (HPLC. The optimum HPLC conditions consisted of a Supelco Discovery C18 column stationary phase, a mobile phase (A: 15 % HPLC grade methanol in deionized water, B: methanol, UV detection at 230 nm, and a flow rate of 0.7 mL/min. The optimized chromatographic conditions were validated and exhibited good specificity and linearity (R 2 > 0.9994–1.0000. The recoveries were in the range of 100.9–102.3 %. The method had good intermediate (%RSD 1.2 and intra-day (%RSD 0.4–1.7 assay precisions. This HPLC method had good accuracy and quality in the determination of dieckol in PRT.

  14. Standard test method for electrochemical critical pitting temperature testing of stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers a procedure for the evaluation of the resistance of stainless steel and related alloys to pitting corrosion based on the concept of the determination of a potential independent critical pitting temperature (CPT). 1.2 This test methods applies to wrought and cast products including but not restricted to plate, sheet, tubing, bar, forgings, and welds, (see Note 1). Note 1—Examples of CPT measurements on sheet, plate, tubing, and welded specimens for various stainless steels can be found in Ref (1). See the research reports (Section 14). 1.3 The standard parameters recommended in this test method are suitable for characterizing the CPT of austenitic stainless steels and other related alloys with a corrosion resistance ranging from that corresponding to solution annealed UNS S31600 (Type 316 stainless steel) to solution annealed UNS S31254 (6 % Mo stainless steel). 1.4 This test method may be extended to stainless steels and other alloys related to stainless steel that have a CPT...

  15. Standard test methods for performance characteristics of metallic bonded resistance strain gages

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 The purpose of this standard is to provide uniform test methods for the determination of strain gauge performance characteristics. Suggested testing equipment designs are included. 1.2 Test Methods E 251 describes methods and procedures for determining five strain gauge parameters: Section Part I—General Requirements 7 Part II—Resistance at a Reference Temperature 8 Part III—Gauge Factor at a Reference Temperature 9 Part IV—Temperature Coefficient of Gauge Factor\t10 Part V—Transverse Sensitivity\t11 Part VI—Thermal Output\t12 1.3 Strain gauges are very sensitive devices with essentially infinite resolution. Their response to strain, however, is low and great care must be exercised in their use. The performance characteristics identified by these test methods must be known to an acceptable accuracy to obtain meaningful results in field applications. 1.3.1 Strain gauge resistance is used to balance instrumentation circuits and to provide a reference value for measurements since all data are...

  16. Microbial diversity and methodological diversity: When standardized methods may or may not be beneficial in deep subseafloor biosphere research

    Science.gov (United States)

    Darch, P. T.

    2015-12-01

    Scientists are often encouraged, and sometimes required, to standardize methods for collecting, analyzing, managing, and reporting data. Methods standardization within and between scientific domains is often considered beneficial for collaboration, developing scientific tools, and curation and sharing of data. However, efforts to standardize are often resisted for a range of social and technical reasons. Here we present findings from a case study of a domain characterized by high methodological diversity. This domain, the deep subseafloor biosphere, studies interactions between subseafloor microbial communities and the physical environment they inhabit. We have conducted 49 interviews and observed practice over a period of 18 months; the study is still ongoing. Domain scientists depend on core samples and data obtained from International Ocean Discovery Program (IODP) cruises. During cruises, basic data are produced about the physical composition of cores, using standard methods. However, no comparable microbiological data is produced on cruises. Many leading deep subseafloor biosphere scientists are concerned that this lack of standardized microbiological data limits their domain's scientific progress. They have identified heterogeneity of methods for microbiological analyses of cores as the major barrier to including such analyses on cruises. Among the actions these scientists have taken to promote methods standardization are journal articles and an international workshop. Despite these efforts, the community is not fully embracing standardization. One of the tensions is between perceived benefits for the community vs. a lack of incentives for individuals to perform necessary standardization work. This work includes meta-analyses to compare methods. However, the community lacks infrastructure and reward structures to support individuals to conduct such work. Another tension is concern amongst some scientists that standardizing methods now will foreclose

  17. An in vitro digestion method adapted for carotenoids and carotenoid esters: moving forward towards standardization.

    Science.gov (United States)

    Rodrigues, Daniele Bobrowski; Mariutti, Lilian Regina Barros; Mercadante, Adriana Zerlotti

    2016-12-07

    In vitro digestion methods are a useful approach to predict the bioaccessibility of food components and overcome some limitations or disadvantages associated with in vivo methodologies. Recently, the INFOGEST network published a static method of in vitro digestion with a proposal for assay standardization. The INFOGEST method is not specific for any food component; therefore, we aimed to adapt this method to assess the in vitro bioaccessibility of carotenoids and carotenoid esters in a model fruit (Byrsonima crassifolia). Two additional steps were coupled to the in vitro digestion procedure, centrifugation at 20 000g for the separation of the aqueous phase containing mixed micelles and exhaustive carotenoid extraction with an organic solvent. The effect of electrolytes, enzymes and bile acids on carotenoid micellarization and stability was also tested. The results were compared with those found with a simpler method that has already been used for carotenoid bioaccessibility analysis. These values were in the expected range for free carotenoids (5-29%), monoesters (9-26%) and diesters (4-28%). In general, the in vitro bioaccessibility of carotenoids assessed by the adapted INFOGEST method was significantly higher (p < 0.05) than those assessed by the simplest protocol, with or without the addition of simulated fluids. Although no trend was observed, differences in bioaccessibility values depended on the carotenoid form (free, monoester or diester), isomerization (Z/E) and the in vitro digestion protocol. To the best of our knowledge, it was the first time that a systematic identification of carotenoid esters by HPLC-DAD-MS/MS after in vitro digestion using the INFOGEST protocol was carried out.

  18. A standardized and safe method of sterile field maintenance during intra-operative horizontal plane fluoroscopy

    Directory of Open Access Journals (Sweden)

    Kaska Serge C

    2010-12-01

    Full Text Available Abstract Background Intra-operative fluoroscopy for orthopaedic procedures frequently involves imaging in the horizontal plane, which requires the lower portion of the C-arm (x-ray tube to be rotated from an unsterile zone (beneath the table into the sterile field. To protect the integrity of the sterile field the C-arm must be draped repeatedly throughout the surgical case. The current, un-standardized, practice employs draping procedures which violate the Association of peri-Operative Registered Nurses (AORN Standards and Recommended Practices, waste time and material, and pose an increased risk for surgical site infection. Presentation of the hypothesis Use of a novel sterile C-arm drape (C-armor that maintains the integrity of the sterile field, will improve operating room efficiency and reduce surgical site infection risk factors. This reduction in risk factors may potentially reduce surgical site infections in orthopaedic surgical cases requiring repeated horizontal x-ray imaging. Testing the Hypothesis Savings in time and material and the reduction in surgical site infection risk factors afforded by using C-armor are intuitive to those skilled in the practice of orthopaedic surgery. Testing for a reduction in the number of microorganisms introduced to the surgical site by improved C-arm draping would be challenging due to the multiple confounding factors during a surgical operation. Determination of an absolute reduction in surgical site infections may be possible, but will require accounting for many confounding variables and a large study sample in order to achieve statistical significance. Implications of the Hypothesis Improved intraoperative workflow, healthcare savings and a reduction in surgical site infection risk factors will be achieved by utilizing a standardized and safe method of sterile field maintenance during intra-operative horizontal plane fluoroscopy.

  19. Characterization of an absorbed dose standard in water through ionometric methods

    International Nuclear Information System (INIS)

    Vargas V, M.X.

    2003-01-01

    In this work the unit of absorbed dose at the Secondary Standard Dosimetry Laboratory (SSDL) of Mexico, is characterized by means of the development of a primary standard of absorbed dose to water, D agua . The main purpose is to diminish the uncertainty in the service of dosimetric calibration of ionization chambers (employed in radiotherapy of extemal beams) that offers this laboratory. This thesis is composed of seven chapters: In Chapter 1 the position and justification of the problem is described, as well as the general and specific objectives. In Chapter 2, a presentation of the main quantities and units used in dosimetry is made, in accordance with the recommendations of the International Commission on Radiation Units and Measurements (ICRU) that establish the necessity to have a coherent system with the international system of units and dosimetric quantities. The concepts of equilibrium and transient equilibrium of charged particles (TCPE) are also presented, which are used later in the quantitative determination of D agua . Finally, since the proposed standard of D agua is of ionometric type, an explanation of the Bragg-Gray and Spencer-Attix cavity theories is made. These theories are the foundation of this type of standards. On the other hand, to guarantee the complete validity of the conditions demanded by these theories it is necessary to introduce correction factors. These factors are determined in Chapters 5 and 6. Since for the calculation of the correction factors Monte Carlo (MC) method is used in an important way, in Chapter 3 the fundamental concepts of this method are presented; in particular the principles of the code MCNP4C [Briesmeister 2000] are detailed, making emphasis on the basis of electron transport and variance reduction techniques used in this thesis. Because a phenomenological approach is carried out in the development of the standard of D agua , in Chapter 4 the characteristics of the Picker C/9 unit, the ionization chamber type

  20. Relation between the national handbook of recommended methods for water data acquisition and ASTM standards

    Science.gov (United States)

    Glysson, G. Douglas; Skinner, John V.

    1991-01-01

    In the late 1950's, intense demands for water and growing concerns about declines in the quality of water generated the need for more water-resources data. About thirty Federal agencies, hundreds of State, county and local agencies, and many private organizations had been collecting water data. However, because of differences in procedures and equipment, many of the data bases were incompatible. In 1964, as a step toward establishing more uniformity, the Bureau of the Budget (now the Office of Management and Budget, OMB) issued 'Circular A-67' which presented guidelines for collecting water data and also served as a catalyst for creating the Office of Water Data Coordination (OWDC) within the U.S. Geological Survey. This paper discusses past, present, and future aspects of the relation between methods in the National Handbook and standards published by ASTM (American Society for Testing and Materials) Committee D-19 on Water's Subcommittee D-19.07 on Sediment, Geomorphology, and Open Channel Flow. The discussion also covers historical aspects of standards - development work jointly conducted by OWDC and ASTM.

  1. Standard test method for determination of resistance to stable crack extension under low-constraint conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This standard covers the determination of the resistance to stable crack extension in metallic materials in terms of the critical crack-tip-opening angle (CTOAc), ψc and/or the crack-opening displacement (COD), δ5 resistance curve (1). This method applies specifically to fatigue pre-cracked specimens that exhibit low constraint (crack-length-to-thickness and un-cracked ligament-to-thickness ratios greater than or equal to 4) and that are tested under slowly increasing remote applied displacement. The recommended specimens are the compact-tension, C(T), and middle-crack-tension, M(T), specimens. The fracture resistance determined in accordance with this standard is measured as ψc (critical CTOA value) and/or δ5 (critical COD resistance curve) as a function of crack extension. Both fracture resistance parameters are characterized using either a single-specimen or multiple-specimen procedures. These fracture quantities are determined under the opening mode (Mode I) of loading. Influences of environment a...

  2. Improved retrieval of cloud base heights from ceilometer using a non-standard instrument method

    Science.gov (United States)

    Wang, Yang; Zhao, Chuanfeng; Dong, Zipeng; Li, Zhanqing; Hu, Shuzhen; Chen, Tianmeng; Tao, Fa; Wang, Yuzhao

    2018-04-01

    Cloud-base height (CBH) is a basic cloud parameter but has not been measured accurately, especially under polluted conditions due to the interference of aerosol. Taking advantage of a comprehensive field experiment in northern China in which a variety of advanced cloud probing instruments were operated, different methods of detecting CBH are assessed. The Micro-Pulse Lidar (MPL) and the Vaisala ceilometer (CL51) provided two types of backscattered profiles. The latter has been employed widely as a standard means of measuring CBH using the manufacturer's operational algorithm to generate standard CBH products (CL51 MAN) whose quality is rigorously assessed here, in comparison with a research algorithm that we developed named value distribution equalization (VDE) algorithm. It was applied to both the profiles of lidar backscattering data from the two instruments. The VDE algorithm is found to produce more accurate estimates of CBH for both instruments and can cope with heavy aerosol loading conditions well. By contrast, CL51 MAN overestimates CBH by 400 m and misses many low level clouds under such conditions. These findings are important given that CL51 has been adopted operationally by many meteorological stations in China.

  3. [Standardization of a method for concentration and detection of enteric viruses from drinking water].

    Science.gov (United States)

    Peláez, Dioselina; Rodríguez, Johanna Alexandra; Rocha, Elva Lucía; Rey, Gloria Janeth

    2010-01-01

    Enteric viruses have been implicated in acute diarrheal disease, food-borne disease, hepatitis A and meningitis outbreaks, in which water was the vehicle of transmission. A concentration method was standardized for the detection of enteric viruses in drinking water. Twenty liters of water were concentrated to 6 ml by filtration and tangential ultrafiltration. Viral solutions of 20 L each were prepared at 1, 10, 50 and 100 TCID50 of Sabin poliovirus type 1 as positive controls. Viral particles were recovered by tissue culture and detected by conventional polymerase chain reaction (PCR), according to the international standards recommended by the Enterovirus Laboratory at the Centers for Disease Control and Prevention, Atlanta, GA. All positive controls showed cytopathic effect on L20B and RD cells and were amplified by conventional PCR directly from samples. Negative controls did not show any amplification or viral cytopathic effect. Tangential ultrafiltration for concentrating viruses proved to be a fast, efficient recovery and reproducible. It has the advantage of allowing the detection (at the 1 TCID50 level) and identification of viruses by RT-PCR and the demonstration of viral infectivity by tissue culture.

  4. a Registration Method of Point Clouds Collected by Mobile LIDAR Using Solely Standard Las Files Information

    Science.gov (United States)

    Gézero, L.; Antunes, C.

    2017-05-01

    In the last few years, LiDAR sensors installed in terrestrial vehicles have been revealed as an efficient method to collect very dense 3D georeferenced information. The possibility of creating very dense point clouds representing the surface surrounding the sensor, at a given moment, in a very fast, detailed and easy way, shows the potential of this technology to be used for cartography and digital terrain models production in large scale. However, there are still some limitations associated with the use of this technology. When several acquisitions of the same area with the same device, are made, differences between the clouds can be observed. The range of that differences can go from few centimetres to some several tens of centimetres, mainly in urban and high vegetation areas where the occultation of the GNSS system introduces a degradation of the georeferenced trajectory. Along this article a different method point cloud registration is proposed. In addition to the efficiency and speed of execution, the main advantages of the method are related to the fact that the adjustment is continuously made over the trajectory, based on the GPS time. The process is fully automatic and only information recorded in the standard LAS files is used, without the need for any auxiliary information, in particular regarding the trajectory.

  5. Standard Guide for Selection of Test Methods for Interlayer Materials for Aerospace Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This guide summarizes the standard test methods available for determining physical and mechanical characteristics of interlayer materials used in multi-ply aerospace transparent enclosures. 1.2 Interlayer materials are used to laminate glass-to-glass, glass-to-plastic, and plastic-to-plastic. Interlayer materials are basically transparent adhesives with high-quality optical properties. They can also serve as an energy absorbing medium, a fail-safe membrane to contain cockpit pressure and to prevent entry of impact debris; a strain insulator to accommodate different thermal expansion rates of members being laminated and as an adherent to prevent spalling of inner surface ply material fragments. The relative importance of an interlayer characteristic will be a function of the prime use it serves in its particular application. 1.3 This guide, as a summary of various methods in Section 2, is intended to facilitate the selection of tests that can be applied to interlayer materials. 1.4 The test methods list...

  6. Standard Test Method for Measuring Neutron Fluence Rate by Radioactivation of Cobalt and Silver

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a suitable means of obtaining the thermal neutron fluence rate, or fluence, in well moderated nuclear reactor environments where the use of cadmium, as a thermal neutron shield as described in Method E262, is undesirable because of potential spectrum perturbations or of temperatures above the melting point of cadmium. 1.2 This test method describes a means of measuring a Westcott neutron fluence rate (Note 1) by activation of cobalt- and silver-foil monitors (See Terminology E170). The reaction 59Co(n,γ)60Co results in a well-defined gamma emitter having a half-life of 1925.28 days (1). The reaction 109Ag(n,˙γ) 110mAg results in a nuclide with a complex decay scheme which is well known and having a half-life of 249.76 days (1). Both cobalt and silver are available either in very pure form or alloyed with other metals such as aluminum. A reference source of cobalt in aluminum alloy to serve as a neutron fluence rate monitor wire standard is available from the National Institute ...

  7. Standard test method for nondestructive assay of radioactive material by tomographic gamma scanning

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method describes the nondestructive assay (NDA) of gamma ray emitting radionuclides inside containers using tomographic gamma scanning (TGS). High resolution gamma ray spectroscopy is used to detect and quantify the radionuclides of interest. The attenuation of an external gamma ray transmission source is used to correct the measurement of the emission gamma rays from radionuclides to arrive at a quantitative determination of the radionuclides present in the item. 1.2 The TGS technique covered by the test method may be used to assay scrap or waste material in cans or drums in the 1 to 500 litre volume range. Other items may be assayed as well. 1.3 The test method will cover two implementations of the TGS procedure: (1) Isotope Specific Calibration that uses standards of known radionuclide masses (or activities) to determine system response in a mass (or activity) versus corrected count rate calibration, that applies to only those specific radionuclides for which it is calibrated, and (2) Respo...

  8. Simplified Symptom Pattern Method for verbal autopsy analysis: multisite validation study using clinical diagnostic gold standards

    Directory of Open Access Journals (Sweden)

    Lozano Rafael

    2011-08-01

    Full Text Available Abstract Background Verbal autopsy can be a useful tool for generating cause of death data in data-sparse regions around the world. The Symptom Pattern (SP Method is one promising approach to analyzing verbal autopsy data, but it has not been tested rigorously with gold standard diagnostic criteria. We propose a simplified version of SP and evaluate its performance using verbal autopsy data with accompanying true cause of death. Methods We investigated specific parameters in SP's Bayesian framework that allow for its optimal performance in both assigning individual cause of death and in determining cause-specific mortality fractions. We evaluated these outcomes of the method separately for adult, child, and neonatal verbal autopsies in 500 different population constructs of verbal autopsy data to analyze its ability in various settings. Results We determined that a modified, simpler version of Symptom Pattern (termed Simplified Symptom Pattern, or SSP performs better than the previously-developed approach. Across 500 samples of verbal autopsy testing data, SSP achieves a median cause-specific mortality fraction accuracy of 0.710 for adults, 0.739 for children, and 0.751 for neonates. In individual cause of death assignment in the same testing environment, SSP achieves 45.8% chance-corrected concordance for adults, 51.5% for children, and 32.5% for neonates. Conclusions The Simplified Symptom Pattern Method for verbal autopsy can yield reliable and reasonably accurate results for both individual cause of death assignment and for determining cause-specific mortality fractions. The method demonstrates that verbal autopsies coupled with SSP can be a useful tool for analyzing mortality patterns and determining individual cause of death from verbal autopsy data.

  9. Canonical integration and analysis of periodic maps using non-standard analysis and life methods

    Energy Technology Data Exchange (ETDEWEB)

    Forest, E.; Berz, M.

    1988-06-01

    We describe a method and a way of thinking which is ideally suited for the study of systems represented by canonical integrators. Starting with the continuous description provided by the Hamiltonians, we replace it by a succession of preferably canonical maps. The power series representation of these maps can be extracted with a computer implementation of the tools of Non-Standard Analysis and analyzed by the same tools. For a nearly integrable system, we can define a Floquet ring in a way consistent with our needs. Using the finite time maps, the Floquet ring is defined only at the locations s/sub i/ where one perturbs or observes the phase space. At most the total number of locations is equal to the total number of steps of our integrator. We can also produce pseudo-Hamiltonians which describe the motion induced by these maps. 15 refs., 1 fig.

  10. Improving the efficacy of the standard DNA differential extraction method for sexual assault evidence.

    Science.gov (United States)

    Timken, Mark D; Klein, Sonja B; Buoncristiani, Martin R

    2018-05-01

    The efficacy of a DNA differential extraction procedure relies on reducing the amount of non-sperm female DNA carryover into the sperm fraction, while providing a sufficient recovery of male DNA from the sperm cell component. A standard approach to this extraction is to use a mild initial lysis step to digest the female (epithelial cell) component in the mixture, followed by a series of centrifugation and wash steps to further purify the resulting sperm-pellet fraction. This sperm fraction is then digested in the presence of a chemical reducing agent in preparation for DNA extraction. This method has been employed with relatively few changes since its introduction in the mid-1980s, despite numerous attempts to develop new or improved procedures. In this report, we demonstrate that it is possible to improve the efficacy of the standard differential extraction by applying simple modifications that can reduce the amount of female DNA carryover into the sperm fraction, with no adverse effects on the recovery of male DNA. In one modification, the addition of a second mild lysis step at the beginning of the differential extraction procedure improved the average male-to-female DNA ratio in the sperm fraction by 3- to 6-fold. In another modification, a "tube transfer" step was added to move the re-suspended sperm pellet to a new tube for the second mild lysis and subsequent wash steps. With this modification, the average male-to-female DNA ratio in the sperm fraction was improved by 4- to 90-fold, relative to results obtained for the non-modified differential extraction method. These modifications may be accomplished using tools and reagents that are already present in most forensic DNA laboratories, so that implementation should be relatively low-cost and practical. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. A standardized method to determine the concentration of extracellular vesicles using tunable resistive pulse sensing

    Directory of Open Access Journals (Sweden)

    Robert Vogel

    2016-09-01

    Full Text Available Background: Understanding the pathogenic role of extracellular vesicles (EVs in disease and their potential diagnostic and therapeutic utility is extremely reliant on in-depth quantification, measurement and identification of EV sub-populations. Quantification of EVs has presented several challenges, predominantly due to the small size of vesicles such as exosomes and the availability of various technologies to measure nanosized particles, each technology having its own limitations. Materials and Methods: A standardized methodology to measure the concentration of extracellular vesicles (EVs has been developed and tested. The method is based on measuring the EV concentration as a function of a defined size range. Blood plasma EVs are isolated and purified using size exclusion columns (qEV and consecutively measured with tunable resistive pulse sensing (TRPS. Six independent research groups measured liposome and EV samples with the aim to evaluate the developed methodology. Each group measured identical samples using up to 5 nanopores with 3 repeat measurements per pore. Descriptive statistics and unsupervised multivariate data analysis with principal component analysis (PCA were used to evaluate reproducibility across the groups and to explore and visualise possible patterns and outliers in EV and liposome data sets. Results: PCA revealed good reproducibility within and between laboratories, with few minor outlying samples. Measured mean liposome (not filtered with qEV and EV (filtered with qEV concentrations had coefficients of variance of 23.9% and 52.5%, respectively. The increased variance of the EV concentration measurements could be attributed to the use of qEVs and the polydisperse nature of EVs. Conclusion: The results of this study demonstrate the feasibility of this standardized methodology to facilitate comparable and reproducible EV concentration measurements.

  12. Simple method for the determination of rosiglitazone in human plasma using a commercially available internal standard.

    Science.gov (United States)

    Mamidi, Rao N V S; Benjamin, Biju; Ramesh, Mullangi; Srinivas, Nuggehally R

    2003-09-01

    To the best of our knowledge, bioanalytical methods to determine rosiglitazone in human plasma reported in literature use internal standards that are not commercially available. Our purpose was to develop a simple method for the determination of rosiglitazone in plasma employing a commercially available internal standard (IS). After the addition of celecoxib (IS), plasma (0.25 mL) samples were extracted into ethyl acetate. The residue after evaporation of the organic layer was dissolved in 750 microL of mobile phase and 50 microL was injected on to HPLC. The separation was achieved using a Hichrom KR 100, 250 x 4.6 mm C(18) with a mobile phase composition potassium dihydrogen phosphate buffer (0.01 m, pH 6.5):acetonitrile:methanol (40:50:10, v/v/v). The flow-rate of the mobile phase was set at 1 mL/min. The column eluate was monitored by fluorescence detector set at an excitation wavelength of 247 nm and emission wavelength of 367 nm. Linear relationships (r(2) > 0.99) were observed between the peak area ratio rosiglitazone to IS vs rosiglitazone concentrations across the concentration range 5-1000 ng/mL. The intra-run precision (%RSD) and accuracy (%Dev) in the measurement of rosiglitazone were 80% for both rosiglitazone and IS from human plasma. The lower limit of quantitation of the assay was 5 ng/mL. In summary, the methodology for rosiglitazone measurement in plasma was simple, sensitive and employed a commercially available IS. Copyright 2003 John Wiley & Sons, Ltd.

  13. Standard Test Method for Water Absorption, Bulk Density, Apparent Porosity, and Apparent Specific Gravity of Fired Whiteware Products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers procedures for determining water absorption, bulk density, apparent porosity, and apparent specific gravity of fired unglazed whiteware products. 1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Comparison of electronic data capture (EDC with the standard data capture method for clinical trial data.

    Directory of Open Access Journals (Sweden)

    Brigitte Walther

    Full Text Available BACKGROUND: Traditionally, clinical research studies rely on collecting data with case report forms, which are subsequently entered into a database to create electronic records. Although well established, this method is time-consuming and error-prone. This study compares four electronic data capture (EDC methods with the conventional approach with respect to duration of data capture and accuracy. It was performed in a West African setting, where clinical trials involve data collection from urban, rural and often remote locations. METHODOLOGY/PRINCIPAL FINDINGS: Three types of commonly available EDC tools were assessed in face-to-face interviews; netbook, PDA, and tablet PC. EDC performance during telephone interviews via mobile phone was evaluated as a fourth method. The Graeco Latin square study design allowed comparison of all four methods to standard paper-based recording followed by data double entry while controlling simultaneously for possible confounding factors such as interview order, interviewer and interviewee. Over a study period of three weeks the error rates decreased considerably for all EDC methods. In the last week of the study the data accuracy for the netbook (5.1%, CI95%: 3.5-7.2% and the tablet PC (5.2%, CI95%: 3.7-7.4% was not significantly different from the accuracy of the conventional paper-based method (3.6%, CI95%: 2.2-5.5%, but error rates for the PDA (7.9%, CI95%: 6.0-10.5% and telephone (6.3%, CI95% 4.6-8.6% remained significantly higher. While EDC-interviews take slightly longer, data become readily available after download, making EDC more time effective. Free text and date fields were associated with higher error rates than numerical, single select and skip fields. CONCLUSIONS: EDC solutions have the potential to produce similar data accuracy compared to paper-based methods. Given the considerable reduction in the time from data collection to database lock, EDC holds the promise to reduce research

  15. Implementing College and Career Standards in Math Methods Course for Early Childhood and Elementary Education Teacher Candidates

    Science.gov (United States)

    Lee, Joohi

    2016-01-01

    This study is purposed to measure the efficacy of implementing College and Career Readiness Standards (CCRS) math standards into math methods courses for early childhood and elementary education teacher candidates at an urban university located in the Dallas and Fort Worth metroplex area. A total of 161 college seniors (teacher candidates)…

  16. Assessing the reliability of the borderline regression method as a standard setting procedure for objective structured clinical examination

    Directory of Open Access Journals (Sweden)

    Sara Mortaz Hejri

    2013-01-01

    Full Text Available Background: One of the methods used for standard setting is the borderline regression method (BRM. This study aims to assess the reliability of BRM when the pass-fail standard in an objective structured clinical examination (OSCE was calculated by averaging the BRM standards obtained for each station separately. Materials and Methods: In nine stations of the OSCE with direct observation the examiners gave each student a checklist score and a global score. Using a linear regression model for each station, we calculated the checklist score cut-off on the regression equation for the global scale cut-off set at 2. The OSCE pass-fail standard was defined as the average of all station′s standard. To determine the reliability, the root mean square error (RMSE was calculated. The R2 coefficient and the inter-grade discrimination were calculated to assess the quality of OSCE. Results: The mean total test score was 60.78. The OSCE pass-fail standard and its RMSE were 47.37 and 0.55, respectively. The R2 coefficients ranged from 0.44 to 0.79. The inter-grade discrimination score varied greatly among stations. Conclusion: The RMSE of the standard was very small indicating that BRM is a reliable method of setting standard for OSCE, which has the advantage of providing data for quality assurance.

  17. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 8, 0.08 Mechanical, Book 1

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    System information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet too & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards are given for plumbing, fire protection, heating, cooling, and special (drinking water cooling systems).

  18. Evaluation of the H-point standard additions method (HPSAM) and the generalized H-point standard additions method (GHPSAM) for the UV-analysis of two-component mixtures.

    Science.gov (United States)

    Hund, E; Massart, D L; Smeyers-Verbeke, J

    1999-10-01

    The H-point standard additions method (HPSAM) and two versions of the generalized H-point standard additions method (GHPSAM) are evaluated for the UV-analysis of two-component mixtures. Synthetic mixtures of anhydrous caffeine and phenazone as well as of atovaquone and proguanil hydrochloride were used. Furthermore, the method was applied to pharmaceutical formulations that contain these compounds as active drug substances. This paper shows both the difficulties that are related to the methods and the conditions by which acceptable results can be obtained.

  19. Standard Setting in a Small Scale OSCE: A Comparison of the Modified Borderline-Group Method and the Borderline Regression Method

    Science.gov (United States)

    Wood, Timothy J.; Humphrey-Murto, Susan M.; Norman, Geoffrey R.

    2006-01-01

    When setting standards, administrators of small-scale OSCEs often face several challenges, including a lack of resources, a lack of available expertise in statistics, and difficulty in recruiting judges. The Modified Borderline-Group Method is a standard setting procedure that compensates for these challenges by using physician examiners and is…

  20. OSPAR standard method and software for statistical analysis of beach litter data.

    Science.gov (United States)

    Schulz, Marcus; van Loon, Willem; Fleet, David M; Baggelaar, Paul; van der Meulen, Eit

    2017-09-15

    The aim of this study is to develop standard statistical methods and software for the analysis of beach litter data. The optimal ensemble of statistical methods comprises the Mann-Kendall trend test, the Theil-Sen slope estimation, the Wilcoxon step trend test and basic descriptive statistics. The application of Litter Analyst, a tailor-made software for analysing the results of beach litter surveys, to OSPAR beach litter data from seven beaches bordering on the south-eastern North Sea, revealed 23 significant trends in the abundances of beach litter types for the period 2009-2014. Litter Analyst revealed a large variation in the abundance of litter types between beaches. To reduce the effects of spatial variation, trend analysis of beach litter data can most effectively be performed at the beach or national level. Spatial aggregation of beach litter data within a region is possible, but resulted in a considerable reduction in the number of significant trends. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 These test methods cover determination of the total normal emittance (Note) of surfaces by means of portable, inspection-meter instruments. Note 1—Total normal emittance (εN) is defined as the ratio of the normal radiance of a specimen to that of a blackbody radiator at the same temperature. The equation relating εN to wavelength and spectral normal emittance [εN (λ)] is where: L b(λ, T) = Planck's blackbody radiation function = c1π −1λ−5(ec2/λT − 1)−1, c1 = 3.7415 × 10−16 W·m 2, c2 = 1.4388 × 10−2 m·K, T = absolute temperature, K, λ = wavelength, m, Lb(λ, T)dλ = Δπ −1T4, and Δ = Stefan-Boltzmann constant = 5.66961 × 10 −8 W·m2·K−4 1.2 These test methods are intended for measurements on large surfaces when rapid measurements must be made and where a nondestructive test is desired. They are particularly useful for production control tests. 1.3 The values stated in SI units are to be regarded as standard. No other units of measu...

  2. A Comparison of Kernel Equating and Traditional Equipercentile Equating Methods and the Parametric Bootstrap Methods for Estimating Standard Errors in Equipercentile Equating

    Science.gov (United States)

    Choi, Sae Il

    2009-01-01

    This study used simulation (a) to compare the kernel equating method to traditional equipercentile equating methods under the equivalent-groups (EG) design and the nonequivalent-groups with anchor test (NEAT) design and (b) to apply the parametric bootstrap method for estimating standard errors of equating. A two-parameter logistic item response…

  3. Handbook for Conducting Standard CMMI Appraisal Method for Process Improvement (SCAMPI) B and C Appraisals, Version 1.1

    National Research Council Canada - National Science Library

    Hayes, Will; Miluk, Gene; Ming, Lisa; Glover, Margaret; Bisgrove, Jane; Cort, Corrine; Penn, Lynn; Jacobson, Nils; Beynon, Don; Allgood, Bruce

    2005-01-01

    The Standard CMMI Appraisal Method for Process Improvement (SCAMPI) provides a well-defined, publicly available set of methodologies for providing appraisals relative to Capability Maturity Model (trademark) Integration (CMMI) models...

  4. A prospective randomised study comparing the jubilee dressing method to a standard adhesive dressing for total hip and knee replacements.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-08-01

    It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing.

  5. A Semi-Automatic Alignment Method for Math Educational Standards Using the MP (Materialization Pattern) Model

    Science.gov (United States)

    Choi, Namyoun

    2010-01-01

    Educational standards alignment, which matches similar or equivalent concepts of educational standards, is a necessary task for educational resource discovery and retrieval. Automated or semi-automated alignment systems for educational standards have been recently available. However, existing systems frequently result in inconsistency in…

  6. Standard test method to determine the performance of tiled roofs to wind-driven rain

    Directory of Open Access Journals (Sweden)

    Sánchez de Rojas, M. I.

    2008-09-01

    Full Text Available The extent to which roof coverings can resist water penetration from the combination of wind and rain, commonly referred to as wind driven rain, is important for the design of roofs. A new project of European Standard prEN 15601 (1 specifies a method of test to determine the performance of the roof covering against wind driven rain. The combined action of wind and rain varies considerably with geographical location of a building and the associated differences in the rain and wind climate. Three windrain conditions and one deluge condition covering Northern Europe Coastal, Central Europe and Southern Europe are specified in the project standard, each subdivided into four wind-speeds and rainfall rates to be applied to the test. The project does not contain information on the level of acceptable performance.Para el diseño de los tejados es importante determinar el punto hasta el cual éstos pueden resistirse a la penetración de agua causada por la combinación de viento y lluvia. Un nuevo proyecto de Norma Europeo prEN 15601 (1 especifica un método de ensayo para determinar el comportamiento del tejado frente a la combinación de viento y lluvia. La acción combinada de viento y lluvia varía considerablemente con la situación geográfica de un edificio y las diferencias asociadas al clima de la lluvia y del viento. El proyecto de norma especifica las condiciones de viento y lluvia y una condición de diluvio para cada una de las tres zonas de Europa: Europa del Norte y Costera, Europa Central y Europa del Sur, cada una subdividida en cuatro condiciones de velocidades de viento y caudal de lluvia para ser aplicadas en los ensayos. El proyecto no contiene la información sobre condiciones aceptables.

  7. A standardized method to determine the concentration of extracellular vesicles using tunable resistive pulse sensing.

    Science.gov (United States)

    Vogel, Robert; Coumans, Frank A W; Maltesen, Raluca G; Böing, Anita N; Bonnington, Katherine E; Broekman, Marike L; Broom, Murray F; Buzás, Edit I; Christiansen, Gunna; Hajji, Najat; Kristensen, Søren R; Kuehn, Meta J; Lund, Sigrid M; Maas, Sybren L N; Nieuwland, Rienk; Osteikoetxea, Xabier; Schnoor, Rosalie; Scicluna, Benjamin J; Shambrook, Mitch; de Vrij, Jeroen; Mann, Stephen I; Hill, Andrew F; Pedersen, Shona

    2016-01-01

    Understanding the pathogenic role of extracellular vesicles (EVs) in disease and their potential diagnostic and therapeutic utility is extremely reliant on in-depth quantification, measurement and identification of EV sub-populations. Quantification of EVs has presented several challenges, predominantly due to the small size of vesicles such as exosomes and the availability of various technologies to measure nanosized particles, each technology having its own limitations. A standardized methodology to measure the concentration of extracellular vesicles (EVs) has been developed and tested. The method is based on measuring the EV concentration as a function of a defined size range. Blood plasma EVs are isolated and purified using size exclusion columns (qEV) and consecutively measured with tunable resistive pulse sensing (TRPS). Six independent research groups measured liposome and EV samples with the aim to evaluate the developed methodology. Each group measured identical samples using up to 5 nanopores with 3 repeat measurements per pore. Descriptive statistics and unsupervised multivariate data analysis with principal component analysis (PCA) were used to evaluate reproducibility across the groups and to explore and visualise possible patterns and outliers in EV and liposome data sets. PCA revealed good reproducibility within and between laboratories, with few minor outlying samples. Measured mean liposome (not filtered with qEV) and EV (filtered with qEV) concentrations had coefficients of variance of 23.9% and 52.5%, respectively. The increased variance of the EV concentration measurements could be attributed to the use of qEVs and the polydisperse nature of EVs. The results of this study demonstrate the feasibility of this standardized methodology to facilitate comparable and reproducible EV concentration measurements.

  8. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 1, 0.01 Foundations and footings

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are given for footings - spread/strip/grade beams; foundation walls; foundation dampproofing/waterproofing; excavation/backfill/ and piles & caissons.

  9. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 5, 0.05 Roofing

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards and inspection methods are presented for built-up membrane; single- ply membrane; metal roofing systems; coated foam membrane; shingles; tiles; parapets; roof drainage system; roof specialties; and skylights.

  10. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 11, 0.11 Specialty systems

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for canopies; loading dock systems; tanks; domes (bulk storage, metal framing); louvers & vents; access floors; integrated ceilings; and mezzanine structures.

  11. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 6, 0.06 Interior construction

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for conventional and specialty partitions, toilet partitions & accessories, interior doors, paint finishes/coatings/ wall covering systems; floor finishing systems; and ceiling systems.

  12. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 12, 0.12 Sitework

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are given for utility distribution systems, central heating, central cooling, electrical, utility support structures, paving roadways/walkways, and tunnels.

  13. Determination of free acid by standard addition method in potassium thiocyanate

    International Nuclear Information System (INIS)

    1981-01-01

    An analytical method for determination of free acidity in all SRP process solutions has been developed. Free acidity was successfully determined in solutions of nitric acid and the nitrates of aluminum, chromium(III), iron(III), mercury(II), nickel(II), thorium, and uranium(VI), at metal-to-acid ratios <2.5. Sample requirements, instrumentation, and mode of operation are similar to those currently used in the Laboratories Department free acid procedures. The simple procedure would be suitable for automation and microprocessor control. The method consists of two additions of known increments of acid into a solution containing the sample aliquot (10 μmoles free acid) and 10 mL 1M potassium thiocyanate. The potential is determined in the initial solution and after each addition with a glass electrode and pH meter. The sample concentration is calculated by solution of three simultaneous Nernst equations. Two programs for this iterative computation are available: one written for the PDP-15 computer and another for a Hewlett-Packard 67 (or 97) programmable calculator. The accuracy of the result is verified by a slope that approximates the theoretical Nernst value. The relative standard deviation is <2.5%. This memorandum includes a survey of experiments with thermometric, pH, and Gran plot titrations in a variety of complexants, from which this particular system and technique logically evolved. The appendix includes a literature survey of sixty references, a discussion of the basic measurements, and a complete analytical procedure. The final step for completion of this RTA is training and consultation at the convenience of the Laboratories Department for demonstration of the method with process samples

  14. Application of the 4 pigammaMethod to the Absolute Standardization of Radioactive Sources of Positron Emitters

    International Nuclear Information System (INIS)

    Peyres Medina, V.; Garcia-Torano Martinez, E.; Roteta Ibarra, M.

    2006-01-01

    We discuss the application of the method known as 4 p i g amma c ounting t o the standardization of positron emitters. Monte Carlo simulations are used to calculate the detection efficiency of positrons emitted by the nuclides 22Na and 18F. Two experimental setups are used, both based on a NaI(Tl) well detector. The results of the standardizations are in good agreement with those obtained by other methods. It is shown that the 4 p i g amma m ethod can be successfully used for the absolute standardization of sources of positron emitters. (Author) 23 refs

  15. Local Correlation Calculations Using Standard and Renormalized Coupled-Cluster Methods

    Science.gov (United States)

    Li, Wei; Piecuch, Piotr; Gour, Jeffrey R.

    2009-03-01

    This article discusses our recent effort toward the extension of the linear scaling local correlation approach, termed 'cluster-in-molecule' and abbreviated as CIM [S. Li, J. Ma, and Y. Jiang, J. Comput. Chem. 23, 237 (2002); S. Li, J. Shen, W. Li, and Y. Jiang, J. Chem. Phys. 125, 074109 (2006)], to the coupled-cluster (CC) theory with singles and doubles (CCSD) and CC methods with singles, doubles, and non-iterative triples, including the standard CCSD(T) approach and the completely renormalized CR-CC(2,3) scheme [P. Piecuch and M. Włoch, J. Chem. Phys. 123, 224105 (2005); P. Piecuch, M. Włoch, J. R. Gour, and A. Kinal, Chem. Phys. Lett. 418, 467 (2006)]. As in the earlier CIM work that dealt with the second-order many-body perturbation theory and CC doubles approach, the main idea of the CIM-CCSD, CIM-CCSD(T), and CIM-CR-CC(2,3) methods is the realization of the fact that the total correlation energy of a large system can be obtained as a sum of contributions from the occupied orthonormal localized molecular orbitals and their respective occupied and unoccupied orbital domains. The CIM-CCSD, CIM-CCSD(T), and CIM-CR-CC(2,3) methods pursued in this work are characterized by high computational efficiency in both the CIM and CC parts, enabling calculations for much larger systems than previously possible. This is achieved by combining the natural linear scaling and embarrassing parallelism of the CIM ansatz with the vectorized CC codes that rely on recursively generated intermediates and fast matrix multiplication routines. By comparing the results of the canonical and CIM-CC calculations for normal alkanes and water clusters, it is demonstrated that the CIM-CCSD, CIM-CCSD(T), and CIM-CR-CC(2,3) approaches recover the corresponding canonical CC correlation energies to within 0.1% or so, while offering linear scaling of the computer costs with the system size and savings in the computer effort by orders of magnitude. By examining the dissociation of dodecane into C

  16. Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method determines the degree of linearity of a photovoltaic device parameter with respect to a test parameter, for example, short-circuit current with respect to irradiance. 1.2 The linearity determined by this test method applies only at the time of testing, and implies no past or future performance level. 1.3 This test method applies only to non-concentrator terrestrial photovoltaic devices. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Optimization of two methods based on ultrasound energy as alternative to European standards for soluble salts extraction from building materials.

    Science.gov (United States)

    Prieto-Taboada, N; Gómez-Laserna, O; Martinez-Arkarazo, I; Olazabal, M A; Madariaga, J M

    2012-11-01

    The Italian recommendation NORMAL 13/83, later replaced by the UNI 11087/2003 norm, were used as standard for soluble salts extraction from construction materials. These standards are based on long-time stirring (72 and 2h, respectively) of the sample in deionized water. In this work two ultrasound based methods were optimized in order to reduce the extraction time while efficiency is improved. The instrumental variables involved in the extraction assisted by ultrasound bath and focused ultrasounds were optimized by experimental design. As long as it was possible, the same non-instrumental parameters values as those of standard methods were used in order to compare the results obtained on a mortar sample showing a black crust by the standards and the optimized methods. The optimal extraction time for the ultrasounds bath was found to be of two hours. Although the extraction time was equal to the standard UNI 11087/2003, the obtained extraction recovery was improved up to 119%. The focused ultrasound system achieved also better recoveries (up to 106%) depending on the analyte in 1h treatment time. The repeatabilities of the proposed ultrasound based methods were comparables to those of the standards. Therefore, the selection of one or the other of the ultrasound based methods will depend on topics such as laboratory facilities or number of samples, and not in aspects related with their quality parameters. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Customisation and Desirable Characteristics of a Standard Method of Measurement for Building Works in Ghana

    Directory of Open Access Journals (Sweden)

    Gabriel Nani

    2012-11-01

    Full Text Available This paper reports a study that identified andcategorised the modifications to the 5thEdition of the British Standard Method ofMeasurement (SMM5 of building works inGhana. Typical modifications involved ‘costinsignificant items’, ‘minor labour items’,‘custom units of measurement’, ‘methodrelated items’, ‘combinable items’,‘subordinate items’, and ‘items of minorinformative impact’. It was also observed thatthe desirable characteristics/ qualities ofstandard methods of measurement (SMM ofbuilding work were noteworthy, since theyprovide insight into the nature of a SMMrequired for the construction industry inGhana.The research reviewed available literature,various SMMs and bills of quantities (BQs.The relevance of the modifications andSMM characteristics identified wasconfirmed by a survey of the opinions ofprofessional quantity surveyors conductedthrough a carefully designed questionnaire.Inferences from the opinion survey formedthe basis for grouping both SMMmodifications found and the desired qualitiesof a SMM for Ghana.Survey respondents confirmed all theidentified modifications to the British SMM,except for the elimination of items of minorinformative impact. It was held that allinformation was relevant in measurement.Desirable characteristics of a SMM were ratedin decreasing order of relevance as: easylocation of items; cost significance; simplicity;thoroughness; ease of cost analysis; goodpractice; conciseness; adoptability; precision;industry practice; stakeholders’ opinion;custom classification; regional relevance; andinclusion of jargon. It was noted that therelevance of these characteristics may varyform one region to the other as a result oftechnological, cultural and legal differences.However, the desired SMM characteristicswere recommended as fundamental indeveloping an appropriate SMM for Ghana.

  19. Instrumental neutron activation analysis of geochemical samples by k{sub 0} standardization method using short lived nuclides

    Energy Technology Data Exchange (ETDEWEB)

    Oura, Yasuji; Kanzaki, Chinatsu; Ebihara, Mitsuru [Tokyo Metropolitan Univ., Graduate School of Science, Tokyo (Japan)

    2003-03-01

    Mg, Al, Ca, Ti, V, and Mn contents in geochemical and cosmochemical samples were analyzed by both k{sub 0} standardization INAA and conventional INAA by a comparison method. The contents of Mg, Al, and Mn by k{sub 0} method were consistent with recommended values and ones by comparison methods. For Ti and V their values are slightly higher than recommended ones. The values by k{sub 0} method were reliable within {+-}10%. (author)

  20. A quantitative and standardized robotic method for the evaluation of arm proprioception after stroke.

    Science.gov (United States)

    Simo, Lucia S; Ghez, Claude; Botzer, Lior; Scheidt, Robert A

    2011-01-01

    Stroke often results in both motor and sensory deficits, which may interact in the manifested functional impairment. Proprioception is known to play important roles in the planning and control of limb posture and movement; however, the impact of proprioceptive deficits on motor function has been difficult to elucidate due in part to the qualitative nature of available clinical tests. We present a quantitative and standardized method for evaluating proprioception in tasks directly relevant to those used to assess motor function. Using a robotic manipulandum that exerted controlled displacements of the hand, stroke participants were evaluated, and compared with a control group, in their ability to detect such displacements in a 2-alternative, forced-choice paradigm. A psychometric function parameterized the decision process underlying the detection of the hand displacements. The shape of this function was determined by a signal detection threshold and by the variability of the response about this threshold. Our automatic procedure differentiates between participants with and without proprioceptive deficits and quantifies functional proprioceptive sensation on a magnitude scale that is meaningful for ongoing studies of degraded motor function in comparable horizontal movements.

  1. Standard test method for determination of reference temperature, to, for ferritic steels in the transition range

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of a reference temperature, To, which characterizes the fracture toughness of ferritic steels that experience onset of cleavage cracking at elastic, or elastic-plastic KJc instabilities, or both. The specific types of ferritic steels (3.2.1) covered are those with yield strengths ranging from 275 to 825 MPa (40 to 120 ksi) and weld metals, after stress-relief annealing, that have 10 % or less strength mismatch relative to that of the base metal. 1.2 The specimens covered are fatigue precracked single-edge notched bend bars, SE(B), and standard or disk-shaped compact tension specimens, C(T) or DC(T). A range of specimen sizes with proportional dimensions is recommended. The dimension on which the proportionality is based is specimen thickness. 1.3 Median KJc values tend to vary with the specimen type at a given test temperature, presumably due to constraint differences among the allowable test specimens in 1.2. The degree of KJc variability among specimen types i...

  2. Use of non standard methods for seismic evaluation of piping systems in existing plants

    International Nuclear Information System (INIS)

    Geraets, L.H.; Lafaille, J.P.; Mignot, P.

    1989-01-01

    Seismic design and analysis of nuclear plant structures, systems and components have requested huge efforts and tremendous costs in the past fifteen years. The extended use of sophisticated, linear response-type methods are responsible for the significant stiffening of the piping systems and the multiplication of supports, and in particular of snubbers. The remedy used against the seismic risk seems to be worse than the disease itself, and safety might be impaired rather than improved. Indeed, stiffening of the system increases the average load level in normal operation, supports do not behave ideally as assumed and snubbers happen to be remarkably unreliable. On the other hand, experience with actual earthquakes shows that industrial facilities designed using very simplistic seismic techniques or even no seismic requirement at all suffer essentially no damage, even in the case of a large earthquake. This paradox challenges the traditional design techniques, and appeals for revised approaches for seismic qualification of piping systems. When the assumption of the occurrence of an earthquake event is made in a plant in operation, which has not been designed using seismic criteria, the use of the standard seismic qualification techniques would still be more questionable. The use of simplified quasi-static techniques, backed when requested with sophisticated time history non linear analyses, allows to assess the seismic adequacy of the safety-related critical piping systems with a minimum backfitting actions

  3. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Copper

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reaction 63Cu(n,α)60Co. The cross section for 60Co produced in this reaction increases rapidly with neutrons having energies greater than about 5 MeV. 60Co decays with a half-life of 1925.27 days (±0.29 days)(1) and emits two gamma rays having energies of 1.1732278 and 1.332492 MeV (1). The isotopic content of natural copper is 69.17 % 63Cu and 30.83 % 65Cu (2). The neutron reaction, 63Cu(n,γ)64Cu, produces a radioactive product that emits gamma rays which might interfere with the counting of the 60Co gamma rays. 1.2 With suitable techniques, fission-neutron fluence rates above 109 cm−2·s−1 can be determined. The 63Cu(n,α)60Co reaction can be used to determine fast-neutron fluences for irradiation times up to about 15 years (for longer irradiations, see Practice E261). 1.3 Detailed procedures for other fast-neutron detectors are referenced in Practice E261. 1.4 This standard does not purport to address all of the...

  4. Microfluidics and numerical simulation as methods for standardization of zebrafish sperm cell activation.

    Science.gov (United States)

    Scherr, Thomas; Knapp, Gerald L; Guitreau, Amy; Park, Daniel Sang-Won; Tiersch, Terrence; Nandakumar, Krishnaswamy; Monroe, W Todd

    2015-01-01

    Sperm cell activation plays a critical role in a range of biological and engineering processes, from fertilization to cryopreservation protocol evaluation. Across a range of species, ionic and osmotic effects have been discovered that lead to activation. Sperm cells of zebrafish (Danio rerio) initiate motility in a hypoosmotic environment. In this study, we employ a microfluidic mixer for the purpose of rapidly diluting the extracellular medium to initiate the onset of cell motility. The use of a microchannel offers a rapid and reproducible mixing profile throughout the device. This greatly reduces variability from trial to trial relative to the current methods of analysis. Coupling these experiments with numerical simulations, we were able to investigate the dynamics of intracellular osmolality as each cell moves along its path through the micromixer. Our results suggest that intracellular osmolality, and hence intracellular ion concentration, only slightly decreases, contrary to the common thought that larger changes in these parameters are required for activation. Utilizing this framework, microfluidics for controlled extracellular environments and associated numerical modeling, has practical applicability in standardizing high-throughput aquatic sperm activation, and more fundamentally, investigations of the intracellular environment leading to motility.

  5. [Reappraisal of the standard method (Light's criteria) for identifying pleural exudates].

    Science.gov (United States)

    Porcel, José M; Peña, José M; Vicente de Vera, Carmina; Esquerda, Aureli

    2006-02-18

    Light's criteria remain the best method for separating pleural exudates from transudates. We assessed their operating characteristics, as well as those resulting from omitting the pleural fluid to serum lactate dehydrogenase (LDH) ratio from the original criteria (abbreviated Light criteria), in a large series of patients. We also searched for the best combination of pleural fluid parameters, including protein, LDH and cholesterol that identify exudates. We conducted a retrospective study of 1,490 consecutive patients with pleural effusion who underwent a diagnostic thoracentesis. There were 1,192 exudates and 298 transudates. Sensitivity, specificity, area under ROC curve, and odds ratio for both individual and combined pleural fluid parameters were calculated. Light's criteria yielded 97.5% sensitivity and 80% specificity. Both abbreviated Light criteria (sensitivity: 95.4%; specificity: 83.3%) and the combined use in an "or" rule of pleural fluid protein and LDH (sensitivity: 95.4%; specificity: 80,2%) had similar discriminative properties than standard criteria. Diagnostic separation of pleural effusions into exudates or transudates can be done effectively thorough the abbreviated Light criteria when the serum LDH value is not available. On the other hand, if venipuncture wants to be avoided (an unusual circumstance) the combination of pleural fluid protein and LDH represents an alternative to Light's criteria.

  6. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Iron

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    DESIG: E 263 09 ^TITLE: Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Iron ^SIGNUSE: Refer to Guide E 844 for guidance on the selection, irradiation, and quality control of neutron dosimeters. Refer to Practice E 261 for a general discussion of the determination of fast-neutron fluence rate with threshold detectors. Pure iron in the form of foil or wire is readily available and easily handled. Fig. 1 shows a plot of cross section as a function of neutron energy for the fast-neutron reaction 54Fe(n,p)54Mn (1). This figure is for illustrative purposes only to indicate the range of response of the 54Fe(n,p)54Mn reaction. Refer to Guide E 1018 for descriptions of recommended tabulated dosimetry cross sections. 54Mn has a half-life of 312.13 days (3) (2) and emits a gamma ray with an energy of 834.845 keV (5). (2) Interfering activities generated by neutron activation arising from thermal or fast neutron interactions are 2.57878 (46)-h 56Mn, 44.95-d (8) 59Fe, and 5.27...

  7. Application of a method to measure uranium enrichment without use of standards

    International Nuclear Information System (INIS)

    Saule, F.A.; Righetti, M.A.

    1998-01-01

    Full text: The determination of uranium enrichment in the many different stages present at a gaseous diffusion enrichment plant (diffusers, cisterns, deposits in pipes, drums with rests of process), or materials of deposit (plates of fuel elements not irradiated and recipients with uranium oxide), that have several geometries and physics properties of the containers, is very important for safeguards inspections. In this work is tested a non destructive analysis technique to determine the value of uranium enrichment of different samples with uranium materials without use of standards, to apply in safeguards inspections. It was used a hyper pure germanium detector with efficiency of 20% to obtain the gamma spectrum of the samples. In each spectrum, were used the net area values corresponding to four lines of U-235 (at 143, 163, 186 and 205 keV) and three lines of U-238 (258, 766 and 1001 keV); these values were analysed with two different methods. The comparison of the calculated and declared values showed a discrepancy of about 10%. (author) [es

  8. Selective methods for the maintainability and standardization of the engineering of a research reactor

    International Nuclear Information System (INIS)

    Rico, N.

    1999-01-01

    Full text: The main point of this work consists of a selective method for the engineering of a research reactor based on parameters, which determine a safer design, installation, operation and maintenance. The variety of tasks in a research reactor are: research, development, production of radioisotopes, etc. They are developed within the installation and the different specialties gathered for these activities. It is necessary to count on an intrinsically safe environment, from the point of view of the investigator, the operator and the maintenance personnel. In general, in both nuclear and conventional installation, independent of its size, certain investment necessities prevail, starting from its design, such as: Nuclear Security, Engineering, Versatility, Production (both for investigation and development)), Conventional Security and Physical Protection, Profitability, etc. The concepts which help us accentuate a greater benefit for the research are not found within these parameters, purpose for which this facility was created. When obtaining a simple engineering the results show an increase in security, decrease in maintenance and operative costs, less ageing and an easy operation. The plant engineering of research reactors could be titled, from the engineering and maintenance point of view, as a technological chaos. Not only for its aspect but for its physiognomy too: inaccessible to certain areas; impassable in its circulation aisles; hard to check and measure; disassemble; clean its components; thus increasing unnecessarily the personnel's exposure time. The facilities of research reactors have different disciplines used as rules for the development of the design, such as nuclear, mechanical, thermodynamical, electronic, chemical, electrical, etc. Common guide lines - from design to operation - are non-existent. This is why different manufacturers and models are found within instruments, pumps, electrical engines, illumination, etc. even when they perform

  9. The Effects of Different Standard Setting Methods and the Composition of Borderline Groups: A Study within a Law Curriculum

    Science.gov (United States)

    Dochy, Filip; Kyndt, Eva; Baeten, Marlies; Pottier, Sofie; Veestraeten, Marlies; Leuven, K. U.

    2009-01-01

    The aim of this study was to examine the effect of different standard setting methods on the size and composition of the borderline group, on the discrimination between different types of students and on the types of students passing with one method but failing with another. A total of 107 university students were classified into 4 different types…

  10. The DST method for solar domestic hot water systems - Research and development for ISO and CEN standards

    NARCIS (Netherlands)

    Visser, H.; Ree, B.G.C. van der

    1996-01-01

    The Dynamic System Test (DST) method for performance characterization of solar domestic hot water (SDHW) systems has been the subject of international research for a number of years. At present, several countries are using the method and it is being standardized on international and European levels.

  11. Effects of introducing a critical path method to standardize treatment and nursing for early discharge from acute psychiatry unit.

    Science.gov (United States)

    Kusaka, Kazuyo; Kanoya, Yuka; Sato, Chifumi

    2006-01-01

    This research aimed to examine whether early discharge can be performed by nurses of a ward participating in the process of critical path method supporting with offer and evaluation of standard and efficient medical treatments and nursing cares. In order to enrich the system that performs hospitable medical treatment and nursing cares standardized at the psychiatry acute term and to prevent chronic, critical path method was introduced into the acute term ward, then the investigation for nursing job satisfaction that was important to establish critical path method was conducted. By introducing critical path method, it became possible to assess the patients in standard, and the subject of business or a system became clear towards early discharge. It became possible to tie up this subject to a future improvement. Consequently, as for comparison of the patient who applied the schedule table of critical path method at the first and second term, the latter decreased the average length of hospitalization period significantly. The satisfaction of the task requirement, which was important to maintain systems, was decreased by the introduction of critical path method but the score of autonomy in satisfaction increased significantly by the improvement of usage of critical path method. From these, it was suggested that the introduction of critical path method in the acute-care unit psychiatry had possibility to aim at standardization of treatment and nursing and patients' early discharge from hospitals.

  12. The use of innovative teaching methods subject in training of bachelor «Standardization and metrology»

    Directory of Open Access Journals (Sweden)

    Yushchik E. V.

    2016-04-01

    Full Text Available the article considers the application of innovative teaching methods by the example of a method of collaborative learning in the laboratory practice in teaching subject «Network information technologies» to guide the preparation of 27.03.01 «Standardization and metroliya».

  13. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 2, 0.02 Substructure

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    System information is given for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. System assembly/component deficiencies and inspection methods are given for slabs-on-grade, columns, and column fireproofing.

  14. A Qualitative Investigation of Panelists' Experiences of Standard Setting Using Two Variations of the Bookmark Method

    Science.gov (United States)

    Hein, Serge F.; Skaggs, Gary E.

    2009-01-01

    Only a small number of qualitative studies have investigated panelists' experiences during standard-setting activities or the thought processes associated with panelists' actions. This qualitative study involved an examination of the experiences of 11 panelists who participated in a prior, one-day standard-setting meeting in which either the…

  15. New clinical validation method for automated sphygmomanometer: a proposal by Japan ISO-WG for sphygmomanometer standard.

    Science.gov (United States)

    Shirasaki, Osamu; Asou, Yosuke; Takahashi, Yukio

    2007-12-01

    Owing to fast or stepwise cuff deflation, or measuring at places other than the upper arm, the clinical accuracy of most recent automated sphygmomanometers (auto-BPMs) cannot be validated by one-arm simultaneous comparison, which would be the only accurate validation method based on auscultation. Two main alternative methods are provided by current standards, that is, two-arm simultaneous comparison (method 1) and one-arm sequential comparison (method 2); however, the accuracy of these validation methods might not be sufficient to compensate for the suspicious accuracy in lateral blood pressure (BP) differences (LD) and/or BP variations (BPV) between the device and reference readings. Thus, the Japan ISO-WG for sphygmomanometer standards has been studying a new method that might improve validation accuracy (method 3). The purpose of this study is to determine the appropriateness of method 3 by comparing immunity to LD and BPV with those of the current validation methods (methods 1 and 2). The validation accuracy of the above three methods was assessed in human participants [N=120, 45+/-15.3 years (mean+/-SD)]. An oscillometric automated monitor, Omron HEM-762, was used as the tested device. When compared with the others, methods 1 and 3 showed a smaller intra-individual standard deviation of device error (SD1), suggesting their higher reproducibility of validation. The SD1 by method 2 (P=0.004) significantly correlated with the participant's BP, supporting our hypothesis that the increased SD of device error by method 2 is at least partially caused by essential BPV. Method 3 showed a significantly (P=0.0044) smaller interparticipant SD of device error (SD2), suggesting its higher interparticipant consistency of validation. Among the methods of validation of the clinical accuracy of auto-BPMs, method 3, which showed the highest reproducibility and highest interparticipant consistency, can be proposed as being the most appropriate.

  16. New semiquantitative assessment of 123I-FP-CIT by an anatomical standardization method

    International Nuclear Information System (INIS)

    Takada, Seiko; Yoshimura, Mana; Shindo, Hiroaki; Saito, Kazuhiro; Koizumi, Kiyoshi; Utsumi, Hiroya; Abe, Kimihiko

    2006-01-01

    We evaluated a new semiquantitative procedure to more easily and objectively estimate the striatal uptake of 123 I-FP-CIT in patients with Parkinsonian syndrome (PS) and essential tremor (ET), using an anatomical standardization method, the Neurostat. Eleven patients with PS and 8 with ET were examined by clinical assessment and 123 I-FP-CIT SPECT imaging. The modified Hoehn and Yahr Staging Scale and Unified Parkinson's Disease Rating Scale (UPDRS) were used to assess the stage and severity of the disease. The co-registered MR and SPECT images were created with fusion software included in Neurostat. On the cross section, which shows the largest area of striate, irregular shaped regions of interest corresponding to the striate and occipital cortex were drawn. Then the ratio of specific striatal uptake to non-specific occipital cortex, V3''(F), was calculated. Another calculation was done by VOIClassic, which is a software included in Neurostat to estimate the counts per voxel of anatomically defined regions such as caudate nucleus, putamen, occipital cortex, and total cortex. Using these count data, the ratio of specific striatal uptake to non-specific occipital cortex, V3''(OC), and total cortex, V3''(TC), was calculated. A fair linear correlation was observed between V3''(OC) and V3''(F) (y=1.53x+1.40; r=0.756; p s =-0.816). However, V3''(OC) and V3''(TC) correlated less with UPDRS (r s =-0.667 and -0.645, respectively). Semiquantitative parameters, V3''(OC) and V3''(TC), calculated by VOIClassic including the Neurostat system are useful and easily calculable parameters as well as V3''(F) for the differential diagnosis of PS from ET. (author)

  17. A mixed methods study of student perceptions of using standardized patients for learning and evaluation.

    Science.gov (United States)

    Giesbrecht, Edward M; Wener, Pamela F; Pereira, Gisèle M

    2014-01-01

    Educators recognize the value of using standardized patients (SPs) when teaching and evaluating clinical skills in rehabilitation entry-to-practice education programs but have published little supporting evidence and have yet to evaluate programmatic SP use from a student perspective. This study explored occupational and physical therapy students' perceptions of SP use in their professional education. Recruiting current and graduated students, we conducted a two-phase mixed-methods sequential-explanatory study integrating data from a quantitative survey (phase 1) and qualitative focus groups with representative students (phase 2). Quantitative data were used to direct the second phase and informed selection of a purposive sample to participate in four focus groups (N=12). The 24-item online survey obtained a 32% response rate (N=167). Mean ratings were high, but significant differences were found between the four subsections of Teaching, SP Experience, Feedback, and Evaluation (P=0.000). Secondary analyses revealed significant differences based on sex, program, and age. Qualitative analysis revealed that students found SP use especially helpful earlier in their program to bridge classroom teaching and clinical practice. Students in the occupational and physical therapy programs approached SP interactions differently in terms of the authenticity, personal investment, and value of SP feedback. Educator feedback was perceived as reflective of technical skill, and SP feedback reflective of therapeutic value, which students prioritized differently. Students identified a preferential continuum of options for learning and practicing skills, ranging from peers and instructors through SPs to actual patients. SPs were perceived as most useful early on in the professional education program, serving to bolster self-confidence and prepare students for clinical fieldwork. Discipline-specific differences impact the perception of SP use and value. Educators need to be aware of

  18. Standard test method for determining whether gas-leak-detector fluid solutions can cause stress corrosion cracking of brass alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers an accelerated test method for evaluating the tendency of gas leak detection fluids (LDFs) to cause stress corrosion cracking (SCC) of brass components in compressed gas service. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  19. Comprehensive approach to the validation of the standard method for total reflection X-ray fluorescence analysis of water.

    Science.gov (United States)

    Borgese, Laura; Dalipi, Rogerta; Riboldi, Alessandro; Bilo, Fabjola; Zacco, Annalisa; Federici, Stefania; Bettinelli, Maurizio; Bontempi, Elza; Depero, Laura Eleonora

    2018-05-01

    In this work, we present the validation of the chemical method for total reflection X-ray fluorescence (TXRF) analysis of water, proposed as a standard to the International Standard Organization. The complete experimental procedure to define the linear calibration range, elements sensitivities, limits of detection and quantification, precision and accuracy is presented for a commercial TXRF spectrometer equipped with Mo X-ray tube. Least squares linear regression, including all statistical tests is performed separately for each element of interest to extract sensitivities. Relative sensitivities with respect to Ga, as internal standard, are calculated. Accuracy and precision of the quantification procedure using Ga as internal standard is evaluated with reference water samples. A detailed discussion on the calibration procedure and the limitation of the use of this method for quantitative analysis of water is presented. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Determination of the delivered hemodialysis dose using standard methods and on-line clearance monitoring

    Directory of Open Access Journals (Sweden)

    Vlatković Vlastimir

    2006-01-01

    Full Text Available Background/aim: Delivered dialysis dose has a cumulative effect and significant influence upon the adequacy of dialysis, quality of life and development of co-morbidity at patients on dialysis. Thus, a great attention is given to the optimization of dialysis treatment. On-line Clearance Monitoring (OCM allows a precise and continuous measurement of the delivered dialysis dose. Kt/V index (K = dialyzer clearance of urea; t = dialysis time; V = patient's total body water, measured in real time is used as a unit for expressing the dialysis dose. The aim of this research was to perform a comparative assessment of the delivered dialysis dose by the application of the standard measurement methods and a module for continuous clearance monitoring. Methods. The study encompassed 105 patients who had been on the chronic hemodialysis program for more than three months, three times a week. By random choice, one treatment per each controlled patient was taken. All the treatments understood bicarbonate dialysis. The delivered dialysis dose was determined by the calculation of mathematical models: Urea Reduction Ratio (URR singlepool index Kt/V (spKt/V and by the application of OCM. Results. Urea Reduction Ratio was the most sensitive parameter for the assessment and, at the same time, it was in the strongest correlation with the other two, spKt/V indexes and OCM. The values pointed out an adequate dialysis dose. The URR values were significantly higher in women than in men, p < 0.05. The other applied model for the delivered dialysis dose measurement was Kt/V index. The obtained values showed that the dialysis dose was adequate, and that, according to this parameter, the women had significantly better dialysis, then the men p < 0.05. According to the OCM, the average value was slightly lower than the adequate one. The women had a satisfactory dialysis according to this index as well, while the delivered dialysis dose was insufficient in men. The difference

  1. A mixed methods study of student perceptions of using standardized patients for learning and evaluation

    Directory of Open Access Journals (Sweden)

    Giesbrecht EM

    2014-08-01

    Full Text Available Edward M Giesbrecht,1 Pamela F Wener,1 Gisèle M Pereira2 1Department of Occupational Therapy, 2Department of Physical Therapy, College of Rehabilitation Sciences, University of Manitoba, Winnipeg, MB, Canada Background: Educators recognize the value of using standardized patients (SPs when teaching and evaluating clinical skills in rehabilitation entry-to-practice education programs but have published little supporting evidence and have yet to evaluate programmatic SP use from a student perspective. This study explored occupational and physical therapy students' perceptions of SP use in their professional education. Methods: Recruiting current and graduated students, we conducted a two-phase mixed-methods sequential-explanatory study integrating data from a quantitative survey (phase 1 and qualitative focus groups with representative students (phase 2. Quantitative data were used to direct the second phase and informed selection of a purposive sample to participate in four focus groups (N=12. Results: The 24-item online survey obtained a 32% response rate (N=167. Mean ratings were high, but significant differences were found between the four subsections of Teaching, SP Experience, Feedback, and Evaluation (P=0.000. Secondary analyses revealed significant differences based on sex, program, and age. Qualitative analysis revealed that students found SP use especially helpful earlier in their program to bridge classroom teaching and clinical practice. Students in the occupational and physical therapy programs approached SP interactions differently in terms of the authenticity, personal investment, and value of SP feedback. Educator feedback was perceived as reflective of technical skill, and SP feedback reflective of therapeutic value, which students prioritized differently. Students identified a preferential continuum of options for learning and practicing skills, ranging from peers and instructors through SPs to actual patients. Conclusion: SPs

  2. Investigation of the Intra- and Interlaboratory Reproducibility of a Small Scale Standardized Supersaturation and Precipitation Method.

    Science.gov (United States)

    Plum, Jakob; Madsen, Cecilie M; Teleki, Alexandra; Bevernage, Jan; da Costa Mathews, Claudia; Karlsson, Eva M; Carlert, Sara; Holm, Rene; Müller, Thomas; Matthews, Wayne; Sayers, Alice; Ojala, Krista; Tsinsman, Konstantin; Lingamaneni, Ram; Bergström, Christel As; Rades, Thomas; Müllertz, Anette

    2017-12-04

    The high number of poorly water-soluble compounds in drug development has increased the need for enabling formulations to improve oral bioavailability. One frequently applied approach is to induce supersaturation at the absorptive site, e.g., the small intestine, increasing the amount of dissolved compound available for absorption. However, due to the stochastic nature of nucleation, supersaturating drug delivery systems may lead to inter- and intrapersonal variability. The ability to define a feasible range with respect to the supersaturation level is a crucial factor for a successful formulation. Therefore, an in vitro method is needed, from where the ability of a compound to supersaturate can be defined in a reproducible way. Hence, this study investigates the reproducibility of an in vitro small scale standardized supersaturation and precipitation method (SSPM). First an intralaboratory reproducibility study of felodipine was conducted, after which seven partners contributed with data for three model compounds; aprepitant, felodipine, and fenofibrate, to determine the interlaboratory reproducibility of the SSPM. The first part of the SSPM determines the apparent degrees of supersaturation (aDS) to investigate for each compound. Each partner independently determined the maximum possible aDS and induced 100, 87.5, 75, and 50% of their determined maximum possible aDS in the SSPM. The concentration-time profile of the supersaturation and following precipitation was obtained in order to determine the induction time (t ind ) for detectable precipitation. The data showed that the absolute values of t ind and aDS were not directly comparable between partners, however, upon linearization of the data a reproducible rank ordering of the three model compounds was obtained based on the β-value, which was defined as the slope of the ln(t ind ) versus ln(aDS) -2 plot. Linear regression of this plot showed that aprepitant had the highest β-value, 15.1, while felodipine and

  3. ARE METHODS USED TO INTEGRATE STANDARDIZED MANAGEMENT SYSTEMS A CONDITIONING FACTOR OF THE LEVEL OF INTEGRATION? AN EMPIRICAL STUDY

    Directory of Open Access Journals (Sweden)

    Merce Bernardo

    2011-09-01

    Full Text Available Organizations are increasingly implementing multiple Management System Standards (M SSs and considering managing the related Management Systems (MSs as a single system.The aim of this paper is to analyze if methods us ed to integrate standardized MSs condition the level of integration of those MSs. A descriptive methodology has been applied to 343 Spanish organizations registered to, at least, ISO 9001 and ISO 14001. Seven groups of these organizations using different combinations of methods have been analyzed Results show that these organizations have a high level of integration of their MSs. The most common method used, was the process map. Organizations using a combination of different methods achieve higher levels of integration than those using a single method. However, no evidence has been found to confirm the relationship between the method used and the integration level achieved.

  4. Liquid scintillation counting standardization of 125I in organic and inorganic samples by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-01-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''I25I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%. (Author) 14 refs

  5. Liquid scintillation counting standardization of ''125 I in organic and inorganic samples by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J.M.; Grau Carles, A.

    1994-01-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''125 I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%

  6. International Harmonisation Of Accounting Standards: The Case For A Mandatory Requirement For The Direct Method Of Reporting Operating Cash Flows

    OpenAIRE

    Christine Yap

    2011-01-01

    Even though standard setters have now embraced cash flow statements there remains ambivalence as to the best format (i.e. direct or indirect method) for disclosing cash flow from operations. In 1987 the FASB asserted that information about the gross amounts of cash receipts and cash payments is more relevant than information about the net amounts of cash receipts and payments. Yet apart from Australia and New Zealand, most standard setting bodies, including the International Accounting Standa...

  7. British Standard method for determining the luminance distribution of electro-optical x-ray image intensifiers

    International Nuclear Information System (INIS)

    1982-01-01

    Under the direction of the Light Electrical Engineering Standards Committee, a British Standard method has been prepared for determining the luminance distribution of electro-optical X-ray image intensifiers. The luminance distribution is determined from the measurement of the luminance over the area of the output image related to conditions of uniform exposure rate in the entrance plane of an electro-optical X-ray image intensifier. (U.K.)

  8. Modified Standard Penetration Test–based Drilled Shaft Design Method for Weak Rocks (Phase 2 Study)

    Science.gov (United States)

    2017-12-15

    In this project, Illinois-specific design procedures were developed for drilled shafts founded in weak shale or rock. In particular, a modified standard penetration test was developed and verified to characterize the in situ condition of weak shales ...

  9. Standard Test Method for Testing Polymeric Seal Materials for Geothermal and/or High Temperature Service Under Sealing Stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers the initial evaluation of (screening) polymeric materials for seals under static sealing stress and at elevated temperatures. 1.2 This test method applies to geothermal service only if used in conjunction with Test Method E 1068. 1.3 The test fluid is distilled water. 1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods provide special techniques needed to determine the electrical performance and spectral response of two-terminal, multijunction photovoltaic (PV) devices, both cell and modules. 1.2 These test methods are modifications and extensions of the procedures for single-junction devices defined by Test Methods E948, E1021, and E1036. 1.3 These test methods do not include temperature and irradiance corrections for spectral response and current-voltage (I-V) measurements. Procedures for such corrections are available in Test Methods E948, E1021, and E1036. 1.4 These test methods may be applied to cells and modules intended for concentrator applications. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and ...

  11. Standardized Ultrasound Hepatic/Renal Ratio and Hepatic Attenuation Rate to Quantify Liver Fat Content: An Improvement Method

    Science.gov (United States)

    Xia, Ming-Feng; Yan, Hong-Mei; He, Wan-Yuan; Li, Xiao-Ming; Li, Chao-Lun; Yao, Xiu-Zhong; Li, Ruo-Kun; Zeng, Meng-Su; Gao, Xin

    2012-01-01

    Accurate measures of liver fat content are essential for investigating the role of hepatic steatosis in the pathophysiology of multiple metabolic disorders. No traditional imaging methods can accurately quantify liver fat content. [1H]-magnetic resonance spectroscopy (MRS) is restricted in large-scale studies because of the practical and technological issues. Previous attempts on computer-aided ultrasound quantification of liver fat content varied in method, and the ultrasound quantitative parameters measured from different ultrasound machines were hardly comparable. We aimed to establish and validate a simple and propagable method for quantitative assessment of liver fat content based on the combination of standardized ultrasound quantitative parameters, using [1H]-MRS as gold standard. Totally 127 participants were examined with both ultrasonography (US) and [1H]-MRS. Ultrasound hepatic/renal echo-intensity ratio (H/R) and ultrasound hepatic echo-intensity attenuation rate (HA) were obtained from ordinary ultrasound images using computer program. Both parameters were standardized using a tissue-mimicking phantom before analysis. Standardized ultrasound H/R and HA were positively correlated with the liver fat content by [1H]-MRS (r = 0.884, P liver fat (adjusted explained variance 78.0%, P liver fat contents between different ultrasound machines and operators was reasonably well. Thus, computer-aided US is a valid method to estimate liver fat content and can be applied extensively after standardization of ultrasound quantitative parameters. PMID:22016092

  12. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1994-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques

  13. Standardization and validation of a novel and simple method to assess lumbar dural sac size

    International Nuclear Information System (INIS)

    Daniels, M.L.A.; Lowe, J.R.; Roy, P.; Patrone, M.V.; Conyers, J.M.; Fine, J.P.; Knowles, M.R.; Birchard, K.R.

    2015-01-01

    Aim: To develop and validate a simple, reproducible method to assess dural sac size using standard imaging technology. Materials and methods: This study was institutional review board-approved. Two readers, blinded to the diagnoses, measured anterior–posterior (AP) and transverse (TR) dural sac diameter (DSD), and AP vertebral body diameter (VBD) of the lumbar vertebrae using MRI images from 53 control patients with pre-existing MRI examinations, 19 prospectively MRI-imaged healthy controls, and 24 patients with Marfan syndrome with prior MRI or CT lumbar spine imaging. Statistical analysis utilized linear and logistic regression, Pearson correlation, and receiver operating characteristic (ROC) curves. Results: AP-DSD and TR-DSD measurements were reproducible between two readers (r = 0.91 and 0.87, respectively). DSD (L1–L5) was not different between male and female controls in the AP or TR plane (p = 0.43; p = 0.40, respectively), and did not vary by age (p = 0.62; p = 0.25) or height (p = 0.64; p = 0.32). AP-VBD was greater in males versus females (p = 1.5 × 10 −8 ), resulting in a smaller dural sac ratio (DSR) (DSD/VBD) in males (p = 5.8 × 10 −6 ). Marfan patients had larger AP-DSDs and TR-DSDs than controls (p = 5.9 × 10 −9 ; p = 6.5 × 10 −9 , respectively). Compared to DSR, AP-DSD and TR-DSD better discriminate Marfan from control subjects based on area under the curve (AUC) values from unadjusted ROCs (AP-DSD p < 0.01; TR-DSD p = 0.04). Conclusion: Individual vertebrae and L1–L5 (average) AP-DSD and TR-DSD measurements are simple, reliable, and reproducible for quantitating dural sac size without needing to control for gender, age, or height. - Highlights: • DSD (L1-L5) does not differ in the AP or TR plane by gender, height, or age. • AP- and TR-DSD measures correlate well between readers with different experience. • Height is positively correlated to AP-VBD in both males and females. • Varying

  14. Evaluation of standard and advanced preprocessing methods for the univariate analysis of blood serum 1H-NMR spectra.

    Science.gov (United States)

    De Meyer, Tim; Sinnaeve, Davy; Van Gasse, Bjorn; Rietzschel, Ernst-R; De Buyzere, Marc L; Langlois, Michel R; Bekaert, Sofie; Martins, José C; Van Criekinge, Wim

    2010-10-01

    Proton nuclear magnetic resonance ((1)H-NMR)-based metabolomics enables the high-resolution and high-throughput assessment of a broad spectrum of metabolites in biofluids. Despite the straightforward character of the experimental methodology, the analysis of spectral profiles is rather complex, particularly due to the requirement of numerous data preprocessing steps. Here, we evaluate how several of the most common preprocessing procedures affect the subsequent univariate analyses of blood serum spectra, with a particular focus on how the standard methods perform compared to more advanced examples. Carr-Purcell-Meiboom-Gill 1D (1)H spectra were obtained for 240 serum samples from healthy subjects of the Asklepios study. We studied the impact of different preprocessing steps--integral (standard method) and probabilistic quotient normalization; no, equidistant (standard), and adaptive-intelligent binning; mean (standard) and maximum bin intensity data summation--on the resonance intensities of three different types of metabolites: triglycerides, glucose, and creatinine. The effects were evaluated by correlating the differently preprocessed NMR data with the independently measured metabolite concentrations. The analyses revealed that the standard methods performed inferiorly and that a combination of probabilistic quotient normalization after adaptive-intelligent binning and maximum intensity variable definition yielded the best overall results (triglycerides, R = 0.98; glucose, R = 0.76; creatinine, R = 0.70). Therefore, at least in the case of serum metabolomics, these or equivalent methods should be preferred above the standard preprocessing methods, particularly for univariate analyses. Additional optimization of the normalization procedure might further improve the analyses.

  15. Application of k0-based internal mono standard instrumental neutron activation analysis method method for composition analysis of stainless steel clad sample

    International Nuclear Information System (INIS)

    Acharya, R.; Nair, A.G.C.; Reddy, A.V.R.; Goswami, A.

    2004-01-01

    The k 0 -based internal mono standard instrumental neutron activation analysis (INAA) method was used for the composition analysis of some irregular shape stainless steel (SS) samples of type SS 316M, which is used as fuel cladding in Indian fast breeder test reactor (FBTR). The method utilizes in situ relative detection efficiency using γ-rays of the activation products present in the sample for overcoming γ-ray self-attenuation. Samples were neutron activated using the thermal column as well as the core position of the reactor and the assay of radioactivity was carried out by high-resolution gamma ray spectrometry. The elements determined were Fe, Cr, Ni, Mo, Mn, Co, Cu, As and W. Since all the major elements (Fe, Cr, Ni, Mo and Mn) were amenable to NAA, the relative elemental concentrations with respect to Fe, obtained by this method, were converted to their absolute values by mass balance. The results were compared with specified compositions and found to be satisfactory. In order to validate these results obtained by the standard-less approach, sub samples of SS 316M in solution forms were analyzed by prevalent relative and k 0 methods of INAA, and results were found to be in good agreement. The accuracy of the internal mono standard INAA method has been evaluated by analyzing an alloy steel certified reference material, CRM 225/1 of British Chemical Standards (BCS)

  16. Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method - Rev.1

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-03-01

    Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI) less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.

  17. Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-16

    Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI) less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.

  18. Standard test method for determination of low concentrations of uranium in oils and organic liquids by X-ray fluorescence

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the steps necessary for the preparation and analysis by X-ray fluorescence (XRF) of oils and organic solutions containing uranium. Two different preparation techniques are described. 1.2 The procedure is valid for those solutions containing 20 to 2000 μg uranium per mL as presented to the spectrometer for the solution technique and 200 to 50 000 μg uranium per g for the pellet technique. 1.3 This test method requires the use of an appropriate internal standard. Care must be taken to ascertain that samples analyzed by this test method do not contain the internal standard or that this contamination, whenever present, has been corrected for mathematically. Such corrections are not addressed in this procedure. Care must be taken that the internal standard and sample medium are compatible; that is, samples must be miscible with tri-n-butyl phosphate (TBP) and must not remove the internal standard from solution. Alternatively, a scatter line may be used as the internal standard. 1....

  19. Using Standard-Sole Cost Method for Performance Gestion Accounting and Calculation Cost in the Machine Building Industry

    Directory of Open Access Journals (Sweden)

    Cleopatra Sendroiu

    2006-07-01

    Full Text Available The main purpose of improving and varying cost calculation methods in the machine building industry is to make them more operational and efficient in supplying the information necessary to the management in taking its decisions. The present cost calculation methods used in the machine building plants - global method and the method per orders - by which a historical cost is determined a posteriori used in deducting and post factum justification of manufacturing expenses does not offer the management the possibility to fully satisfy its need for information. We are talking about a change of conception in applying certain systems, methods and work techniques, according to the needs of efficient administration of production and the plant seen as a whole. The standard-cost method best answers to the needs of the effective management of the value side of the manufacturing process and raising economic efficiency. We consider that, in the machine building industry, these objectives can be achieved by using the standard - sole cost alternative of the standard-cost method.

  20. Using Standard-Sole Cost Method for Performance Gestion Accounting and Calculation Cost in the Machine Building Industry

    Directory of Open Access Journals (Sweden)

    Aureliana Geta Roman

    2006-09-01

    Full Text Available The main purpose of improving and varying cost calculation methods in the machine building industry is to make them more operational and efficient in supplying the information necessary to the management in taking its decisions. The present cost calculation methods used in the machine building plants – global method and the method per orders – by which a historical cost is determined a posteriori used in deducting and post factum justification of manufacturing expenses does not offer the management the possibility to fully satisfy its need for information. We are talking about a change of conception in applying certain systems, methods and work techniques, according to the needs of efficient administration of production and the plant seen as a whole. The standard-cost method best answers to the needs of the effective management of the value side of the manufacturing process and raising economic efficiency. We consider that, in the machine building industry, these objectives can be achieved by using the standard - sole cost alternative of the standard-cost method.

  1. User-generated quality standards for youth mental health in primary care: a participatory research design using mixed methods.

    Science.gov (United States)

    Graham, Tanya; Rose, Diana; Murray, Joanna; Ashworth, Mark; Tylee, André

    2014-10-01

    To develop user-generated quality standards for young people with mental health problems in primary care using a participatory research model. 50 young people aged 16-25 from community settings and primary care participated in focus groups and interviews about their views and experiences of seeking help for mental health problems in primary care, cofacilitated by young service users and repeated to ensure respondent validation. A second group of young people also aged 16-25 who had sought help for any mental health problem from primary care or secondary care within the last 5 years were trained as focus groups cofacilitators (n=12) developed the quality standards from the qualitative data and participated in four nominal groups (n=28). 46 quality standards were developed and ranked by young service users. Agreement was defined as 100% of scores within a two-point region. Group consensus existed for 16 quality standards representing the following aspects of primary care: better advertising and information (three); improved competence through mental health training and skill mix within the practice (two); alternatives to medication (three); improved referral protocol (three); and specific questions and reassurances (five). Alternatives to medication and specific questions and reassurances are aspects of quality which have not been previously reported. We have demonstrated the feasibility of using participatory research methods in order to develop user-generated quality standards. The development of patient-generated quality standards may offer a more formal method of incorporating the views of service users into quality improvement initiatives. This method can be adapted for generating quality standards applicable to other patient groups. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Water quality - Determination of tritium activity concentration - Liquid scintillation counting method (International Standard Publication ISO 9698:1989)

    International Nuclear Information System (INIS)

    Stefanik, J.

    1999-01-01

    This International Standard specifies a method for the determination of tritiated water ([ 3 H]H 2 O) activity concentration in water by liquid scintillation counting. The method is applicable to all types of water including seawater with tritium activity concentrations of up to 10 6 Bq/m 3 when using 20 ml counting vials. Below tritium activity concentrations of about 5 x 10 4 Bq/m 3[ 8], a prior enrichment step and/or the measurement of larger sample volumes can significantly improve the accuracy of the determination and lower the limit of detection. Tritium activity concentrations higher than 10 6 Bq/m 3 may be determined after appropriate dilution with distilled water of proven low tritium content. An alternative method for the determination of these higher activities involves increasing the tritium activity concentrations of the internal standard solution. The method is not applicable to the analysis of organically bound tritium; its determination requires an oxidative digestion

  3. Standard test method for conducting drop-weight test to determine nil-ductility transition temperature of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of the nil-ductility transition (NDT) temperature of ferritic steels, 5/8 in. (15.9 mm) and thicker. 1.2 This test method may be used whenever the inquiry, contract, order, or specification states that the steels are subject to fracture toughness requirements as determined by the drop-weight test. 1.3 The values stated in inch-pound units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Methods and problems of testing TiO2 photocatalytic products and standardization

    Czech Academy of Sciences Publication Activity Database

    Peterka, F.; Kavan, Ladislav; Balek, Vladimír; Šubrt, Jan; Štengl, Václav; Lukeš, Petr; Krýsa, J.; Jirkovský, Jaromír

    2002-01-01

    Roč. 9, č. 12 (2002), s. 194-195 ISSN 1345-5818. [Symposium on Recent Advances in Photocatalysis /9./. Tokio, 02.12.2002] R&D Projects: GA MŠk ME 540 Institutional research plan: CEZ:AV0Z2043910 Keywords : titanium oxide, photocatalysis, standardization Subject RIV: CB - Analytical Chemistry, Separation

  5. Standardization of Type 2 Diabetes Outpatient Expenditure with Bundled Payment Method in China

    Directory of Open Access Journals (Sweden)

    Guo-Chao Xu

    2016-01-01

    Conclusions: We argued that it is feasible to implement bundled payment on type 2 diabetes outpatient services. Bundled payment is effective to control the increase of outpatient expenditure. Further improvements are needed for the implementation of bundled payment reimbursement standards, together with relevant policies and measures.

  6. Common Core State Standards for Mathematics: How Well Do the Textbook and Instructional Methods Align?

    Science.gov (United States)

    Rawding, Denise M.

    2016-01-01

    The Common Core Math Standards were written to address concerns that the math curriculum in the United States was not focused and coherent. Based on national and international assessments, the United States math scores have remained stagnant, while other countries have seen significant growth in their scores. This study, designed as an action…

  7. Reflections on How DGNB(UD) Certification Standards Effect Design Methods

    DEFF Research Database (Denmark)

    Mansfeldt Faurbjerg, Lise; Redder Pedersen, Stine; Jensen, Lotte Bjerregaard

    2013-01-01

    DGNB is an abbreviation of Deutsche Gesellshaft für Nachhaltiges Bauen, a German sustainability standard and certification system that has operated for a decade and that was appointed as the official Danish system by Green Building Council (GBC) Denmark in 2009. In 2012 GBC Denmark launched...

  8. Orthogonal analytical methods for botanical standardization: Determination of green tea catechins by qNMR and LC-MS/MS

    OpenAIRE

    Napolitano, José G.; Gödecke, Tanja; Lankin, David C.; Jaki, Birgit U.; McAlpine, James B.; Chen, Shao-Nong; Pauli, Guido F.

    2013-01-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative 1H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development o...

  9. FLOW-INJECTION CALIBRATION OF INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY USING THE GENERALIZED STANDARD ADDITIONS METHOD

    OpenAIRE

    GINE, MF; KRUG, FJ; FILHO, HB; DOSREIS, BF; ZAGATTO, EAG; BRUNS, RE

    1988-01-01

    The generalised standard additions method (GSAM), employing least-squares regression, provides a convenient method for obtaining the calibration matrix (K-matrix) in multi-element analysis. The GSAM is based on the response variations obtained after the addition of known incremental amounts of the interfering and test elements to the samples. As application of the GSAM requires a number of additions, automation is recommended for routine analytical work. Any automated procedure for implementi...

  10. Ficus deltoidea Standardization: Analytical Methods for Bioactive Markers in Deltozide Tablet 200 MG

    International Nuclear Information System (INIS)

    Hazlina Ahmad Hassali; Zainah Adam; Rosniza Razali

    2016-01-01

    Standardization of herbal materials based on their chemical and biological profile is an important prerequisite for development of herbal product. The phyto pharmaceutical product that has been developed by Medical Technology Division, Malaysian Nuclear Agency is DELTOZIDE TABLET 200 MG containing 200 mg of spray-dried aqueous extract of Ficus deltoidea var kunstleri leaf as the active ingredient. Ficus deltoidea Jack or locally known as Mas Cotek is a South East Asian native plant traditionally used to treat several diseases. Pharmacological data showed that this plant exhibited good antioxidant, anti-diabetic and anti-inflammatory properties. It is important to establish the chemical profiles and determine the phytochemicals content of this plant as it is popularly used in traditional medicines. Thus, the present study reports on the comprehensive phytochemicals evaluation of bioactive markers from this extract for the development of DELTOZIDE TABLET 200 MG . Characterization of extract using LCMS/ MS Triple TOF System showed the presence of major constituents representing vitexin, isovitexin, gallic acid, catechinic, api genin, epicatechin and caffeoylquinic acid along with other minor constituents. The extract was standardized by ultra-high performance liquid chromatography (UHPLC) using two pharmacologically active markers, vitexin and isovitexin. Furthermore, qualitative determination of phytochemicals showed the presence of important phyto-constituents namely anthraquinones, terpenoids, flavonoids, tannins, phlobatannins, alkaloids, saponins, cardiac glycosides, steroids and phenols in the aqueous extract of Ficus deltoidea. Quantitative determination of phytochemicals revealed that the amount of total phenolic content (TPC; Gallic acid as standard) and total flavonoid content (TFC; Quercetin as standard) were 126.67±3.98 mg GAE/ g extract and 9.08±0.36 mg QE/ g extract respectively. The generated data provides some explanation for its wide usage in

  11. Improved synthesis methods of standards used for quantitative determination of total isothiocyanates from broccoli in human urine

    DEFF Research Database (Denmark)

    Kristensen, Mette; Krogholm, Kirstine Suszkiewicz; Frederiksen, Hanne

    2007-01-01

    A well-known method for quantification of isothiocyanates (ITCs) and their metabolites is the condensation reaction with 1,2-benzenedithiole to produce 1,3-benzodithiole-2-thione, which can be quantified by high-performance liquid chromatography. Standards of an ITC metabolite and 1,3-benzodithiole...

  12. Standard errors and confidence intervals for correlations corrected for indirect range restriction: A simulation study comparing analytic and bootstrap methods.

    Science.gov (United States)

    Kennet-Cohen, Tamar; Kleper, Dvir; Turvall, Elliot

    2018-02-01

    A frequent topic of psychological research is the estimation of the correlation between two variables from a sample that underwent a selection process based on a third variable. Due to indirect range restriction, the sample correlation is a biased estimator of the population correlation, and a correction formula is used. In the past, bootstrap standard error and confidence intervals for the corrected correlations were examined with normal data. The present study proposes a large-sample estimate (an analytic method) for the standard error, and a corresponding confidence interval for the corrected correlation. Monte Carlo simulation studies involving both normal and non-normal data were conducted to examine the empirical performance of the bootstrap and analytic methods. Results indicated that with both normal and non-normal data, the bootstrap standard error and confidence interval were generally accurate across simulation conditions (restricted sample size, selection ratio, and population correlations) and outperformed estimates of the analytic method. However, with certain combinations of distribution type and model conditions, the analytic method has an advantage, offering reasonable estimates of the standard error and confidence interval without resorting to the bootstrap procedure's computer-intensive approach. We provide SAS code for the simulation studies. © 2017 The British Psychological Society.

  13. Analysis of standard and innovative methods for allocating upstream and refinery GHG emissions to oil products

    NARCIS (Netherlands)

    Moretti, Christian; Moro, Alberto; Edwards, Robert A; Rocco, Matteo Vincenzo; Colombo, Emanuela

    2017-01-01

    Alternative fuel policies need accurate and transparent methods to find the embedded carbon intensity of individual refinery products. This study investigates different ways of allocating greenhouse gases emissions deriving from refining and upstream crude oil supply. Allocation methods based on

  14. Standard test methods for analysis of sintered gadolinium oxide-uranium dioxide pellets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 These test methods cover procedures for the analysis of sintered gadolinium oxide-uranium dioxide pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Section Carbon (Total) by Direct CombustionThermal Conductivity Method C1408 Test Method for Carbon (Total) in Uranium Oxide Powders and Pellets By Direct Combustion-Infrared Detection Method Chlorine and Fluorine by Pyrohydrolysis Ion-Selective Electrode Method C1502 Test Method for Determination of Total Chlorine and Fluorine in Uranium Dioxide and Gadolinium Oxide Gadolinia Content by Energy-Dispersive X-Ray Spectrometry C1456 Test Method for Determination of Uranium or Gadolinium, or Both, in Gadolinium Oxide-Uranium Oxide Pellets or by X-Ray Fluorescence (XRF) Hydrogen by Inert Gas Fusion C1457 Test Method for Determination of Total Hydrogen Content of Uranium Oxide Powders and Pellets by Carrier Gas Extraction Isotopic Uranium Composition by Multiple-Filament Surface-Ioni...

  15. Standard test method for nondestructive assay of special nuclear material holdup using Gamma-Ray spectroscopic methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes gamma-ray methods used to nondestructively measure the quantity of 235U, or 239Pu remaining as holdup in nuclear facilities. Holdup occurs in all facilities where nuclear material is processed, in process equipment, in exhaust ventilation systems and in building walls and floors. 1.2 This test method includes information useful for management, planning, selection of equipment, consideration of interferences, measurement program definition, and the utilization of resources (1, 2, 3, 4). 1.3 The measurement of nuclear material hold up in process equipment requires a scientific knowledge of radiation sources and detectors, transmission of radiation, calibration, facility operations and error analysis. It is subject to the constraints of the facility, management, budget, and schedule; plus health and safety requirements; as well as the laws of physics. The measurement process includes defining measurement uncertainties and is sensitive to the form and distribution of the material...

  16. Comparison of Three Methods for Laryngeal Mask Airway Insertion in Adults: Standard, Lateral and Rotational

    Directory of Open Access Journals (Sweden)

    Ata Mahmoodpoor

    2014-03-01

    Full Text Available Determination of an optimal Laryngeal Mask Airway (LMA insertion technique is of great importance as unsuccessful prolonged insertion and multiple attempts are associated with adverse respiratory effects and trauma. The purpose of this study was to compare the ease of insertion of LMA using the standard approach with lateral and rotational techniques. 150 adult patients undergoing general anesthesia using LMA were randomized into one of the three mentioned techniques: standard, rotational and lateral. The time for LMA insertion, number of LMA insertion attempts and LMA insertion success rate were noted for all patients. Demographic characteristic of patients between three groups did not have significant difference. Patients irritation and time for LMA insertion was significantly less in lateral technique (P

  17. Assessment of Sexual Dysfunction Symptoms in Female Drug Users: Standardized vs. Unstandardized Methods.

    Science.gov (United States)

    Diehl, Alessandra; Rassool, G Hussein; dos Santos, Manoel Antônio; Pillon, Sandra Cristina; Laranjeira, Ronaldo

    2016-01-01

    The aim of this study is to evaluate whether there is a difference in the identified prevalence between the assessment of symptoms of sexual dysfunction in female drug users using a standardized scale and by means of a nonstandardized set of questions about sexual dysfunctions. A cross-sectional study was conducted with two groups of substance-dependent women using the Drug Abuse Screening Test, the Short Alcohol Dependence Data questionnaire, the Fagerström Test for Nicotine Dependence for the evaluation of the severity of dependence, and the Arizona Sexual Experience Scale. In both groups, the severity of dependence and the prevalence of symptoms of sexual dysfunctions in women were similar. The use of standardized and nonstandardized instruments to assess sexual dysfunction symptoms is an essential resource for the provision of good-quality care to this clientele.

  18. Absolute standardization of 121Te by gamma spectrometry using the peak-sum method

    International Nuclear Information System (INIS)

    Araujo, Miriam Taina Ferreira de

    2015-01-01

    This work has as main objective to develop a methodology for identification and quantification of impurities in the production process of the radiopharmaceutical [ 123 I]Nal. As a specific goal we mention the process of absolute standardization of 121 Te. The determination of some nuclear parameters associated with the decay is the step of secondary endpoints where data obtained will be compared with the existing literature

  19. Liquid scintillation counting standardization of Na129I by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1996-01-01

    We describe a sample preparation procedure for liquid scintillation measurements of stable solution of Na''129I. The counting stability and spectral evolution of this solution is studied in HiSafe''tmII, Ultima-Gold''tm and Insta-Gel''r. The liquid scintillation measurements have been carried efficiencies lower than 0.4%. the solution has been standardized in terms of activity concentration to an overall uncertainty of 0.46% (k=1 )

  20. Approximate Bayesian computation (ABC) coupled with Bayesian model averaging method for estimating mean and standard deviation

    OpenAIRE

    Kwon, Deukwoo; Reis, Isildinha M.

    2016-01-01

    Background: We proposed approximate Bayesian computation with single distribution selection (ABC-SD) for estimating mean and standard deviation from other reported summary statistics. The ABC-SD generates pseudo data from a single parametric distribution thought to be the true distribution of underlying study data. This single distribution is either an educated guess, or it is selected via model selection using posterior probability criterion for testing two or more candidate distributions. F...

  1. ISO 9000 standards and their application in a radiodiagnostics department: methods of implementation and evaluation

    International Nuclear Information System (INIS)

    Bello, E.; Iraola, B.; Pagola, C.; Olano, J. G.

    2000-01-01

    To present our experience in the implementation of a standardized quality assurance system in the Radiodiagnostics Services at two hospitals of the health care network of the Basque Country Autonomous Community: the Bidasoa County Hospitals in Hondarribia, belonging to the Basque Health Service-Osakidetza, and the Maria Cristina Red Cross Hospital in San Sebastian. The first stage of this project, the ultimate purpose of which is to achieve the certification of the quality system, consisted in the detailed study of the ISO 9002 Standard, applicable to the activities of a Radiological Diagnostics Services. Following the analysis of the requirements described in the 20 sections that comprise this standard, the second stage focused on its adaptation to clinical and managerial use in our services. This involved their general revision and, as a consequence, the development-update of our Procedure and Protocol Guidelines, which constituted the core of the documental support of the so-called Quality Guidelines. This third stage, overlapping the preceding one, included the progressive implementation of the document-based conclusions, generating the corresponding records of the activities carried out. Having successfully undergone an audit for certification in which the auditors observed total compliance with the different activities as defined in the documents comprising the Quality Guidelines, both of the above mentioned services obtained the corresponding certificate issued by two different properly accredited organizations (AENOR and DET NORSKE veritas, respectively). (Author) 25 refs

  2. Improving the Knowledge and Attitude on 'Standard Days Method' of Family Planning Through a Promotional Program Among Indian Postgraduate Students.

    Science.gov (United States)

    Menachery, Philby Babu; Noronha, Judith Angelitta; Fernanades, Sweety

    2017-08-01

    The 'Standard Days Method' is a fertility awareness-based method of family planning that identifies day 8 through day 19 of the menstrual cycle as fertile days during which a woman is likely to conceive with unprotected intercourse. The study was aimed to determine the effectiveness of a promotional program on the 'Standard Days Method' in terms of improving the knowledge scores and attitude scores. A pre-experimental one-group pretest-posttest research design was adopted. The samples included 365 female postgraduate students from selected colleges of Udupi Taluk, Karnataka. The data was collected using self-administered questionnaires. The plan for the promotional program was also established. The findings of the study were analyzed using the descriptive and inferential statistics. The mean pretest and posttest knowledge scores were computed, and it was found that there was an increase in the mean knowledge score from 8.96 ± 3.84 to 32.64 ± 5.59, respectively. It was observed that the promotional program on 'Standard Days Method' was effective in improving the knowledge ( p  family planning was effective in improving the knowledge and attitude of the postgraduate female students. This will enable the women to adopt this method and plan their pregnancies naturally and reduce the side effects of using oral contraceptives.

  3. Standard Test Method for Application and Analysis of Helium Accumulation Fluence Monitors for Reactor Vessel Surveillance, E706 (IIIC)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes the concept and use of helium accumulation for neutron fluence dosimetry for reactor vessel surveillance. Although this test method is directed toward applications in vessel surveillance, the concepts and techniques are equally applicable to the general field of neutron dosimetry. The various applications of this test method for reactor vessel surveillance are as follows: 1.1.1 Helium accumulation fluence monitor (HAFM) capsules, 1.1.2 Unencapsulated, or cadmium or gadolinium covered, radiometric monitors (RM) and HAFM wires for helium analysis, 1.1.3 Charpy test block samples for helium accumulation, and 1.1.4 Reactor vessel (RV) wall samples for helium accumulation. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Biomechanical analysis using FEA and experiments of a standard plate method versus three cable methods for fixing acetabular fractures with simultaneous THA.

    Science.gov (United States)

    Aziz, Mina S R; Dessouki, Omar; Samiezadeh, Saeid; Bougherara, Habiba; Schemitsch, Emil H; Zdero, Radovan

    2017-08-01

    Acetabular fractures potentially account for up to half of all pelvic fractures, while pelvic fractures potentially account for over one-tenth of all human bone fractures. This is the first biomechanical study to assess acetabular fracture fixation using plates versus cables in the presence of a total hip arthroplasty, as done for the elderly. In Phase 1, finite element (FE) models compared a standard plate method versus 3 cable methods for repairing an acetabular fracture (type: anterior column plus posterior hemi-transverse) subjected to a physiological-type compressive load of 2207N representing 3 x body weight for a 75kg person during walking. FE stress maps were compared to choose the most mechanically stable cable method, i.e. lowest peak bone stress. In Phase 2, mechanical tests were then done in artificial hemipelvises to compare the standard plate method versus the optimal cable method selected from Phase 1. FE analysis results showed peak bone stresses of 255MPa (Plate method), 205MPa (Mears cable method), 250MPa (Kang cable method), and 181MPa (Mouhsine cable method). Mechanical tests then showed that the Plate method versus the Mouhsine cable method selected from Phase 1 had higher stiffness (662versus 385N/mm, p=0.001), strength (3210versus 2060N, p=0.009), and failure energy (8.8versus 6.2J, p=0.002), whilst they were statistically equivalent for interfragmentary sliding (p≥0.179) and interfragmentary gapping (p≥0.08). The Plate method had superior mechanical properties, but the Mouhsine cable method may be a reasonable alternative if osteoporosis prevents good screw thread interdigitation during plating. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Quantitative determination and validation of octreotide acetate using1H-NMR spectroscopy with internal standard method.

    Science.gov (United States)

    Yu, Chen; Zhang, Qian; Xu, Peng-Yao; Bai, Yin; Shen, Wen-Bin; Di, Bin; Su, Meng-Xiang

    2018-01-01

    Quantitative nuclear magnetic resonance (qNMR) is a well-established technique in quantitative analysis. We presented a validated 1 H-qNMR method for assay of octreotide acetate, a kind of cyclic octopeptide. Deuterium oxide was used to remove the undesired exchangeable peaks, which was referred to as proton exchange, in order to make the quantitative signals isolated in the crowded spectrum of the peptide and ensure precise quantitative analysis. Gemcitabine hydrochloride was chosen as the suitable internal standard. Experimental conditions, including relaxation delay time, the numbers of scans, and pulse angle, were optimized first. Then method validation was carried out in terms of selectivity, stability, linearity, precision, and robustness. The assay result was compared with that by means of high performance liquid chromatography, which is provided by Chinese Pharmacopoeia. The statistical F test, Student's t test, and nonparametric test at 95% confidence level indicate that there was no significant difference between these two methods. qNMR is a simple and accurate quantitative tool with no need for specific corresponding reference standards. It has the potential of the quantitative analysis of other peptide drugs and standardization of the corresponding reference standards. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Rapid detection of coliforms in drinking water of Arak city using multiplex PCR method in comparison with the standard method of culture (Most Probably Number).

    Science.gov (United States)

    Fatemeh, Dehghan; Reza, Zolfaghari Mohammad; Mohammad, Arjomandzadegan; Salomeh, Kalantari; Reza, Ahmari Gholam; Hossein, Sarmadian; Maryam, Sadrnia; Azam, Ahmadi; Mana, Shojapoor; Negin, Najarian; Reza, Kasravi Alii; Saeed, Falahat

    2014-05-01

    To analyse molecular detection of coliforms and shorten the time of PCR. Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number (MPN) method for 16 artificial and 101 field samples. The molecular method was also conducted on isolated coliforms from positive MPN samples; standard sample for verification of microbial method certificated reference material; isolated strains from certificated reference material and standard bacteria. The PCR and electrophoresis parameters were changed for reducing the operation time. Results of PCR for lacZ and uidA genes were similar in all of standard, operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR. PCR results were confirmed by MPN culture method by sensitivity 86% (95% CI: 0.71-0.93). Also the total execution time, with a successful change of factors, was reduced to less than two and a half hour. Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city. It's recommended to be used at least as an initial screening test, and then the positive samples could be randomly tested by MPN.

  7. Creep-life prediction and standard error analysis of type 316LN stainless steel by time-temperature parametric methods

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Ryu, Woo Seog; Yoon, Song Nam; Yi, Won

    2005-01-01

    A number of creep rupture data for type 316LN stainless steel were collected through literature survey or experimental data produced in KAERI. Using these data, polynomial equations for predicting creep life were obtained by Larson-Miller (L-M), Orr-Sherby-Dorn (O-S-D) and Manson-Haferd (M-H) parameters using Time-Temperature Parametric (TTP) methods. Standard Error of Estimate (SEE) values for the each parameter was obtained with different temperatures through the statistical process of the creep data. The results of L-M, O-S-D and M-H methods showed good creep-life prediction, but M-H method showed better agreement than L-M and O-S-D methods. Especially, it was found that SEE values of M-H method at 700 .deg. C were lower than that of L-M and O-S-D methods

  8. Use of expert panels to define the reference standard in diagnostic research: a systematic review of published methods and reporting.

    Directory of Open Access Journals (Sweden)

    Loes C M Bertens

    2013-10-01

    Full Text Available BACKGROUND: In diagnostic studies, a single and error-free test that can be used as the reference (gold standard often does not exist. One solution is the use of panel diagnosis, i.e., a group of experts who assess the results from multiple tests to reach a final diagnosis in each patient. Although panel diagnosis, also known as consensus or expert diagnosis, is frequently used as the reference standard, guidance on preferred methodology is lacking. The aim of this study is to provide an overview of methods used in panel diagnoses and to provide initial guidance on the use and reporting of panel diagnosis as reference standard. METHODS AND FINDINGS: PubMed was systematically searched for diagnostic studies applying a panel diagnosis as reference standard published up to May 31, 2012. We included diagnostic studies in which the final diagnosis was made by two or more persons based on results from multiple tests. General study characteristics and details of panel methodology were extracted. Eighty-one studies were included, of which most reported on psychiatry (37% and cardiovascular (21% diseases. Data extraction was hampered by incomplete reporting; one or more pieces of critical information about panel reference standard methodology was missing in 83% of studies. In most studies (75%, the panel consisted of three or fewer members. Panel members were blinded to the results of the index test results in 31% of studies. Reproducibility of the decision process was assessed in 17 (21% studies. Reported details on panel constitution, information for diagnosis and methods of decision making varied considerably between studies. CONCLUSIONS: Methods of panel diagnosis varied substantially across studies and many aspects of the procedure were either unclear or not reported. On the basis of our review, we identified areas for improvement and developed a checklist and flow chart for initial guidance for researchers conducting and reporting of studies

  9. Novel implementation of an ISO standard method for primary vibration calibration by laser interferometry

    CSIR Research Space (South Africa)

    Veldman, CS

    2003-01-01

    Full Text Available An implementation of the sine-approximation method of ISO 16063-11 (primary vibration calibration by laser interferometry) is described. The quadrature interference signals are generated using an interferometer as described in method 3 of ISO 16063...

  10. Integrating 6th Grade Geometry Standards into a Waldorf Methods Charter School

    Science.gov (United States)

    Watterson, Ilie Alma

    2006-01-01

    Many Waldorf methods charter schools are opening up in California today. They are publicly funded schools bringing Waldorf methods into public education. In today's political climate all public schools must pass the state's bar of academic success measured by their Adequate Yearly Progress (AYP). Because these scores are based largely on…

  11. Comparison of two standard test methods for determining explosion limits of gases at atmospheric conditions.

    Science.gov (United States)

    De Smedt, G; de Corte, F; Notelé, R; Berghmans, J

    1999-12-31

    A comparison is made between two internationally accepted methods to determine the explosion limits of gases at atmospheric pressure and room temperature (20 l sphere - DIN 51649). Significant differences (about 1 vol.%) in the upper explosion limits (UEL) values are found for four hydrocarbons tested. A new criterion is proposed which leads to close agreement between the UEL values obtained by the two methods.

  12. Comparison of a Local Linearization Algorithm with Standard Numerical Integration Methods for Real-Time Simulation

    DEFF Research Database (Denmark)

    Cook, Gerald; Lin, Ching-Fang

    1980-01-01

    The local linearization algorithm is presented as a possible numerical integration scheme to be used in real-time simulation. A second-order nonlinear example problem is solved using different methods. The local linearization approach is shown to require less computing time and give significant...... improvement in accuracy over the classical second-order integration methods....

  13. Comparison of two standardized methods of methacholine inhalation challenge in young adults

    DEFF Research Database (Denmark)

    Siersted, H C; Walker, C M; O'Shaughnessy, A D

    2000-01-01

    by these two methods is not well established. This study measured airway responsiveness to methacholine by dosimeter and tidal breathing methods in 47 healthy asthmatic subjects aged 20-44 yrs. Tests were performed within 1 week and in random order. Baseline forced expiratory volume in one second (FEV1) varied by...

  14. Standard test method for plane-strain (Chevron-Notch) fracture toughness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers the determination of plane-strain (chevron-notch) fracture toughnesses, KIv or KIvM, of metallic materials. Fracture toughness by this method is relative to a slowly advancing steady state crack initiated at a chevron-shaped notch, and propagating in a chevron-shaped ligament (Fig. 1). Some metallic materials, when tested by this method, exhibit a sporadic crack growth in which the crack front remains nearly stationary until a critical load is reached. The crack then becomes unstable and suddenly advances at high speed to the next arrest point. For these materials, this test method covers the determination of the plane-strain fracture toughness, KIvj or KIvM, relative to the crack at the points of instability. Note 1—One difference between this test method and Test Method E 399 (which measures KIc) is that Test Method E 399 centers attention on the start of crack extension from a fatigue precrack. This test method makes use of either a steady state slowly propagating crack, or a...

  15. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  16. Electronic laboratory quality assurance program: A method of enhancing the prosthodontic curriculum and addressing accreditation standards.

    Science.gov (United States)

    Moghadam, Marjan; Jahangiri, Leila

    2015-08-01

    An electronic quality assurance (eQA) program was developed to replace a paper-based system and to address standards introduced by the Commission on Dental Accreditation (CODA) and to improve educational outcomes. This eQA program provides feedback to predoctoral dental students on prosthodontic laboratory steps at New York University College of Dentistry. The purpose of this study was to compare the eQA program of performing laboratory quality assurance with the former paper-based format. Fourth-year predoctoral dental students (n=334) who experienced both the paper-based and the electronic version of the quality assurance program were surveyed about their experiences. Additionally, data extracted from the eQA program were analyzed to identify areas of weakness in the curriculum. The study findings revealed that 73.8% of the students preferred the eQA program to the paper-based version. The average number of treatments that did not pass quality assurance standards was 119.5 per month. This indicated a 6.34% laboratory failure rate. Further analysis of these data revealed that 62.1% of the errors were related to fixed prosthodontic treatment, 27.9% to partial removable dental prostheses, and 10% to complete removable dental prostheses in the first 18 months of program implementation. The eQA program was favored by dental students who have experienced both electronic and paper-based versions of the system. Error type analysis can yield the ability to create customized faculty standardization sessions and refine the didactic and clinical teaching of the predoctoral students. This program was also able to link patient care activity with the student's laboratory activities, thus addressing the latest requirements of the CODA regarding the competence of graduates in evaluating laboratory work related to their patient care. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. A standardized method for quantitating the complement-mediated immune complex solubilizing capacity of human serum

    DEFF Research Database (Denmark)

    Baatrup, G; Peterson, I; Svehag, S E

    1983-01-01

    A standardized radioassay for measuring the complement-mediated immune complex solubilizing capacity (CMSC) and the initial kinetics of the solubilization (IKS) reaction is described. The total complement (C)-mediated solubilizing capacity was determined after incubation of diluted serum and 125I......-BSA-anti-BSA. Percentage C-mediated solubilization (CMS) was measured after centrifugation by determining the distribution of radioactivity. The dependency of CMSC upon factors such as serum dilution and buffer system used, amount of IC added to serum, serum storage conditions and centrifugation conditions...

  18. Lattice Boltzmann method for simulation of compressible flows on standard lattices.

    Science.gov (United States)

    Prasianakis, Nikolaos I; Karlin, Iliya V

    2008-07-01

    The recently introduced lattice Boltzmann model for thermal flow simulation on a standard lattice [Prasianakis and Karlin, Phys. Rev. E 76, 016702 (2007)] is studied numerically in the case where compressibility effects are essential. It is demonstrated that the speed of sound and shock propagation are described correctly in a wide temperature range, and that it is possible to take into account additional physics such as heat sources and sinks. A remarkable simplicity of the model makes it viable for engineering applications in subsonic flows with large temperature and density variations.

  19. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  20. Determinations of silicon and phosphorus in Pepperbush standard reference material by neutron activation and x-ray fluorescence methods

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Nishio, Hirofumi; Hayashi, Takeshi; Kusakabe, Toshio; Iwata, Shiro.

    1987-01-01

    Silicon and phosphorus contents in Pepperbush standard reference material were determined by neutron activation and X-ray fluorescence methods. In neutron activation analysis, β-ray spectra of 32 P produced by 31 P(n,γ) 32 P reaction on Pepperbush and standard samples were measured by a low background β-ray spectrometer. In X-ray fluorescence analysis, the standard samples were prepared by mixing the Pepperbush powder with silicon dioxide and diammonium hydrogenphosphate. Characteristic X-rays from the samples were analyzed by a wavelength dispersive X-ray fluorescence spectrometer. From the β and X-ray intensities, silicon and phosphorus contents in Pepperbush were determined to be 1840 ± 80 and 1200 ± 50 μg g -1 , respectively. (author)

  1. Standard guide for choosing a method for determining the index of refraction and dispersion of glass

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This guide identifies and describes seven test methods for measuring the index of refraction of glass, with comments relevant to their uses such that an appropriate choice of method can be made. Four additional methods are mentioned by name, and brief descriptive information is given in Annex A1. The choice of a test method will depend upon the accuracy required, the nature of the test specimen that can be provided, the instrumentation available, and (perhaps) the time required for, or the cost of, the analysis. Refractive index is a function of the wavelength of light; therefore, its measurement is made with narrow-bandwidth light. Dispersion is the physical phenomenon of the variation of refractive index with wavelength. The nature of the test-specimen refers to its size, form, and quality of finish, as described in each of the methods herein. The test methods described are mostly for the visible range of wavelengths (approximately 400 to 780m); however, some methods can be extended to the ultraviolet a...

  2. Standard test method for determining susceptibility to stress-corrosion cracking of 2XXX and 7XXX Aluminum alloy products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This test method covers a uniform procedure for characterizing the resistance to stress-corrosion cracking (SCC) of high-strength aluminum alloy wrought products for the guidance of those who perform stress-corrosion tests, for those who prepare stress-corrosion specifications, and for materials engineers. 1.2 This test method covers method of sampling, type of specimen, specimen preparation, test environment, and method of exposure for determining the susceptibility to SCC of 2XXX (with 1.8 to 7.0 % copper) and 7XXX (with 0.4 to 2.8 % copper) aluminum alloy products, particularly when stressed in the short-transverse direction relative to the grain structure. 1.3 The values stated in SI units are to be regarded as standard. The inch-pound units in parentheses are provided for information. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and de...

  3. Standard test methods for chemical and spectrochemical analysis of nuclear-Grade silver-indium-cadmium alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1990-01-01

    1.1 These test methods cover procedures for the chemical and spectrochemical analysis of nuclear grade silver-indium-cadmium (Ag-In-Cd) alloys to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Silver, Indium, and Cadmium by a Titration Method 7-15 Trace Impurities by Carrier-Distillation Spectro- chemical Method 16-22 1.3 The values stated in SI units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard and precautionary statements, see Section 5 and Practices E50. 7.1 This test method is applicable to the determination of silver, indium, and cadmium in alloys of approximately 80 % silver, 15 % indium, and 5 % cadmium used in nuclear reactor control r...

  4. Standard test method for isotopic analysis of hydrolyzed uranium hexafluoride and uranyl nitrate solutions by thermal ionization mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This method applies to the determination of isotopic composition in hydrolyzed nuclear grade uranium hexafluoride. It covers isotopic abundance of 235U between 0.1 and 5.0 % mass fraction, abundance of 234U between 0.0055 and 0.05 % mass fraction, and abundance of 236U between 0.0003 and 0.5 % mass fraction. This test method may be applicable to other isotopic abundance providing that corresponding standards are available. 1.2 This test method can apply to uranyl nitrate solutions. This can be achieved either by transforming the uranyl nitrate solution to a uranyl fluoride solution prior to the deposition on the filaments or directly by depositing the uranyl nitrate solution on the filaments. In the latter case, a calibration with uranyl nitrate standards must be performed. 1.3 This test method can also apply to other nuclear grade matrices (for example, uranium oxides) by providing a chemical transformation to uranyl fluoride or uranyl nitrate solution. 1.4 This standard does not purport to address al...

  5. A Comparison of pical Root Resorption in Incisors after Fixed Orthodontic Treatment with Standard Edgewise and Straight Wire (MBT) Method.

    Science.gov (United States)

    Zahed Zahedani, Sm; Oshagh, M; Momeni Danaei, Sh; Roeinpeikar, Smm

    2013-09-01

    One of the major outcomes of orthodontic treatment is the apical root resorption of teeth moved during the treatment. Identifying the possible risk factors, are necessary for every orthodontist. The aim of this study was to compare the rate of apical root resorption after fixed orthodontic treatment with standard edgewise and straight wire (MBT) method, and also to evaluate other factors effecting the rate of root resorption in orthodontic treatments. In this study, parallel periapical radiographs of 127 patients imaging a total of 737 individual teeth, were collected. A total of 76 patients were treated by standard edgewise and 51 patients by straight wire method. The periapical radiographs were scanned and then the percentage of root resorption was calculated by Photoshop software. The data were analyzed by Paired-Samples t-test and the Generalized Linear Model adopting the SPSS 15.0. In patients treated with straight wire method (MBT), mean root resorption was 18.26% compared to 14.82% in patients treated with standard edgewise technique (ptechnique can be attributed to more root movement in pre-adjusted MBT technique due to the brackets employed in this method.

  6. Blood pressure measurement in children: which method? which is the gold standard.

    Science.gov (United States)

    Vidal, Enrico; Murer, Luisa; Matteucci, Maria Chiara

    2013-01-01

    The burden of hypertension has become increasingly prevalent in children. Hypertension that begins in childhood can carry on into adulthood, therefore early detection, accurate diagnosis and effective therapy of high blood pressure may improve long-term outcomes of children and adolescents. As far as pediatric hypertension is concerned, doubts still persist about the right instruments, modalities and standards of reference that should be used in routine practice. Due to the dynamic process of growth and development, many physiological parameters undergo intensive change with age. Therefore, in children, the definition of hypertension can not rely on a single blood pressure level but should be based on age- and height-specific percentiles. In this review, we introduce the nephrologist to the correct definition of high blood pressure in children. Moreover, we specifically address the main characteristics of different modalities for blood pressure measurement in children, focusing on practical aspects. The latest international guidelines and appropriate standards of reference for office, ambulatory and home blood pressure data collection are presented. As clinicians are being faced with a greater number of children with hypertension, they should be aware of these peculiarities.

  7. Comparison of methods for estimating Wet-Bulb Globe Temperature index from standard meteorological measurements.

    Science.gov (United States)

    Patel, Tejash; Mullen, Stephen P; Santee, William R

    2013-08-01

    Environmental heat illness and injuries are a serious concern for the Army and Marines. Currently, the Wet-Bulb Globe Temperature (WBGT) index is used to evaluate heat injury risk. The index is a weighted average of dry-bulb temperature (Tdb), black globe temperature (Tbg), and natural wet-bulb temperature (Tnwb). The WBGT index would be more widely used if it could be determined using standard weather instruments. This study compares models developed by Liljegren at Argonne National Laboratory and by Matthew at the U.S. Army Institute of Environmental Medicine that calculate WBGT using standard meteorological measurements. Both models use air temperature (Ta), relative humidity, wind speed, and global solar radiation (RG) to calculate Tnwb and Tbg. The WBGT and meteorological data used for model validation were collected at Griffin, Georgia and Yuma Proving Ground (YPG), Arizona. Liljegren (YPG: R(2) = 0.709, p < 0.01; Griffin: R(2) = 0.854, p < 0.01) showed closer agreement between calculated and actual WBGT than Matthew (YPG: R(2) = 0.630, p < 0.01; Griffin: R(2) = 0.677, p < 0.01). Compared to actual WBGT heat categorization, the Matthew model tended to underpredict compared to Liljegren's classification. Results indicate Liljegren is an acceptable alternative to direct WBGT measurement, but verification under other environmental conditions is needed. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.

  8. Standard Test Method for Calibration of Non-Concentrator Photovoltaic Secondary Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers calibration and characterization of secondary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device. 1.2 Secondary reference cells are calibrated indoors using simulated sunlight or outdoors in natural sunlight by reference to a primary reference cell previously calibrated to the same desired reference spectral irradiance distribution. 1.3 Secondary reference cells calibrated according to this test method will have the same radiometric traceability as the of the primary reference cell used for the calibration. Therefore, if the primary reference cell is traceable to the World Radiometric Reference (WRR, see Test Method E816), the resulting secondary reference cell will also be traceable to the WRR. 1.4 This test method appli...

  9. California teachers' perceptions of standards-based reform in middle school science: A mixed-methods study

    Science.gov (United States)

    Leggett, Allison Gail Wilson

    The No Child Left Behind (NCLB) Act of 2001 presented one of the most significant and comprehensive literacy reforms in many years (McDonnell, 2005; U.S. Department of Education, 2006). The era of school accountability and standards based reform has brought many challenges and changes to public schools. Increasingly, public officials and educational administrators are asked to use standards based assessments to make high-stakes decisions, such as whether a student will move on to the next grade level or receive a diploma (American Psychological Association, 2005). It is important to understand any shifts in teachers' perceptions and to identify the changes teachers are making as they implement standards-based reform. This mixed-methods study was designed to assess teachers' perceptions of changes related to standards-based reform as supported by Fullan's (2001) change theory and transformational leadership theory. Survey questions sought to identify teacher perceptions of changes in curriculum, instruction and daily practice as schools documented and incorporated standards-based reform and began focusing on preparing students for the California Standards Test in Science (CSTS). Using descriptive statistical analysis and in-depth interviews, results show favorable insight towards standards-based reform. The survey was distributed to 30 middle school science teachers from 10 low-performing schools in Los Angeles, California. Results were analyzed using Spearman rank-ordered correlations. Interviews were conducted on middle school teachers represented by each grade level. Teachers who receive more support from administrators have more positive attitudes toward all aspects of SBR and the CSTS as measured in this study. No school should overlook the potential of a supportive administration in its effort to improve school programs.

  10. Development and Validation of Acyclovir HPLC External Standard Method in Human Plasma: Application to Pharmacokinetic Studies

    Directory of Open Access Journals (Sweden)

    Selvadurai Muralidharan

    2014-01-01

    Full Text Available A simple, rapid, and selective RP-HPLC method was developed for the estimation of acyclovir in human plasma. The method involves a simple protein precipitation technique. Chromatographic separation was carried out on a reverse phase C18 column using mixture of 5 mM ammonium acetate (pH 4.0 and acetonitrile (40 : 60, v/v at a flow rate of 1.0 mL/min with UV detection at 290 nm. The retention time of acyclovir was 4.12 minutes. The method was validated and found to be linear in the range of 25.0–150.0 ng/mL. Validation studies were achieved by using the fundamental parameters, including accuracy, precision, selectivity, sensitivity, linearity and range, stability studies, limit of detection (LOD, and limit of quantitation (LOQ. It shows recovery at 91.0% which is more precise and accurate compared to the other method. These results indicated that the bioanalytical method was linear, precise, and accurate. The new bioanalytical method was successfully applied to a pharmacokinetic linearity study in human plasma.

  11. Standard Test Method for Electrical Performance of Concentrator Terrestrial Photovoltaic Modules and Systems Under Natural Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of photovoltaic concentrator modules and systems under natural sunlight using a normal incidence pyrheliometer. 1.2 The test method is limited to module assemblies and systems where the geometric concentration ratio specified by the manufacturer is greater than 5. 1.3 This test method applies to concentrators that use passive cooling where the cell temperature is related to the air temperature. 1.4 Measurements under a variety of conditions are allowed; results are reported under a select set of concentrator reporting conditions to facilitate comparison of results. 1.5 This test method applies only to concentrator terrestrial modules and systems. 1.6 This test method assumes that the module or system electrical performance characteristics do not change during the period of test. 1.7 The performance rating determined by this test method applies only at the period of the test, and implies no past or future performance level. 1.8...

  12. Standard Test Method for Mechanical Hydrogen Embrittlement Evaluation of Plating/Coating Processes and Service Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method describes mechanical test methods and defines acceptance criteria for coating and plating processes that can cause hydrogen embrittlement in steels. Subsequent exposure to chemicals encountered in service environments, such as fluids, cleaning treatments or maintenance chemicals that come in contact with the plated/coated or bare surface of the steel, can also be evaluated. 1.2 This test method is not intended to measure the relative susceptibility of different steels. The relative susceptibility of different materials to hydrogen embrittlement may be determined in accordance with Test Method F1459 and Test Method F1624. 1.3 This test method specifies the use of air melted AISI E4340 steel per SAE AMS-S-5000 (formerly MIL-S-5000) heat treated to 260 – 280 ksi (pounds per square inch x 1000) as the baseline. This combination of alloy and heat treat level has been used for many years and a large database has been accumulated in the aerospace industry on its specific response to exposure...

  13. Evaluation and standardization of neutron activation analysis according to the K0 method in the RP-10 reactor

    International Nuclear Information System (INIS)

    Montoya R, E.

    1995-01-01

    It has been characterized and standardized an irradiation of the RP-10 Research Nuclear Reactor for use of the K 0 method of neutron activation analysis using the Hoegdahl convention; also it has been evaluate the behaviour of such method in regard to the accuracy and precision of the results obtained in the quantitative multi elemental analysis of several certified materials of reference. In order to prove that the analytical method is totally under statistical control, it has been used the Heydorn method. It has been verified that the method is exact, precise and reliable to determine the aluminium, antimuonium, arsenic, bromine, calcium, chloride, copper, magnesium, manganese, sodium, titanium, vanadium, zinc and other elements. Also, they are discussed, in regard to the use of K 0 constants, the different formalisms employed to calculate the integral of the reaction rate by nucleus in the activation. (author). 58 refs., 18 tabs., 6 figs

  14. Quantitative mass spectrometric analysis of dipeptides in protein hydrolysate by a TNBS derivatization-aided standard addition method.

    Science.gov (United States)

    Hanh, Vu Thi; Kobayashi, Yutaro; Maebuchi, Motohiro; Nakamori, Toshihiro; Tanaka, Mitsuru; Matsui, Toshiro

    2016-01-01

    The aim of this study was to establish, through a standard addition method, a convenient quantification assay for dipeptides (GY, YG, SY, YS, and IY) in soybean hydrolysate using 2,4,6-trinitrobenzene sulfonate (TNBS) derivatization-aided LC-TOF-MS. Soybean hydrolysate samples (25.0 mg mL(-1)) spiked with target standards were subjected to TNBS derivatization. Under the optimal LC-MS conditions, five target dipeptides derivatized with TNBS were successfully detected. Examination of the standard addition curves, with a correlation coefficient of r(2) > 0.979, provided a reliable quantification of the target dipeptides, GY, YG, SY, YS, and IY, in soybean hydrolysate to be 424 ± 20, 184 ± 9, 2188 ± 199, 327 ± 16, and 2211 ± 133 μg g(-1) of hydrolysate, respectively. The proposed LC-MS assay is a reliable and convenient assay method, with no interference from matrix effects in hydrolysate, and with no requirement for the use of an isotope labeled internal standard. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Application of standard and modified Eh-Star test method for induction motor stray load losses and efficiency measurement

    Directory of Open Access Journals (Sweden)

    Koprivica Branko

    2012-01-01

    Full Text Available The aim of this paper is to present the application of one simple and accurate method for the measurement of stray load losses (additional load losses in induction machines. That is the Eh-Star method given in the IEC 60034-2-1 standard. In this paper the theoretical background of the method and the measurement procedure have been explained. All measurements have been performed using modern measurement systems based on a personal computer, data acquisition cards and LabVIEW software. According to the measured results for the stray load losses, the efficiency of the induction motor has been calculated. The efficiency obtained has been compared with the IEC standard efficiency classes, in order to determine the efficiency class of the tested motor. Additionally, measurements have been performed using the modified Eh-Star method. The results obtained have been compared with those obtained using the Eh-Star method. The advantages and disadvantages of both methods have been analyzed in this paper.

  16. Identification of Water Quality Significant Parameter with Two Transformation/Standardization Methods on Principal Component Analysis and Scilab Software

    Directory of Open Access Journals (Sweden)

    Jovan Putranda

    2016-09-01

    Full Text Available Water quality monitoring is prone to encounter error on its recording or measuring process. The monitoring on river water quality not only aims to recognize the water quality dynamic, but also to evaluate the data to create river management policy and water pollution in order to maintain the continuity of human health or sanitation requirement, and biodiversity preservation. Evaluation on water quality monitoring needs to be started by identifying the important water quality parameter. This research objected to identify the significant parameters by using two transformation or standardization methods on water quality data, which are the river Water Quality Index, WQI (Indeks Kualitas Air, Sungai, IKAs transformation or standardization method and transformation or standardization method with mean 0 and variance 1; so that the variability of water quality parameters could be aggregated with one another. Both of the methods were applied on the water quality monitoring data which its validity and reliability have been tested. The PCA, Principal Component Analysis (Analisa Komponen Utama, AKU, with the help of Scilab software, has been used to process the secondary data on water quality parameters of Gadjah Wong river in 2004-2013, with its validity and reliability has been tested. The Scilab result was cross examined with the result from the Excel-based Biplot Add In software. The research result showed that only 18 from total 35 water quality parameters that have passable data quality. The two transformation or standardization data methods gave different significant parameter type and amount result. On the transformation or standardization mean 0 variances 1, there were water quality significant parameter dynamic to mean concentration of each water quality parameters, which are TDS, SO4, EC, TSS, NO3N, COD, BOD5, Grease Oil and NH3N. On the river WQI transformation or standardization, the water quality significant parameter showed the level of

  17. Spectrophotometric methods for the determination of urea in real samples using silver nanoparticles by standard addition and 2nd order derivative methods.

    Science.gov (United States)

    Ali, Nauman; Ismail, Muhammad; Khan, Adnan; Khan, Hamayun; Haider, Sajjad; Kamal, Tahseen

    2018-01-15

    In this work, we have developed simple, sensitive and inexpensive methods for the spectrophotometric determination of urea in urine samples using silver nanoparticles (AgNPs). The standard addition and 2nd order derivative methods were adopted for this purpose. AgNPs were prepared by chemical reduction of AgNO 3 with hydrazine using 1,3-di-(1H-imidazol-1-yl)-2-propanol (DIPO) as a stabilizing agent in aqueous medium. The proposed methods were based on the complexation of AgNPs with urea. Using this concept, urea in the urine samples was successfully determined spectrophotometric methods. The results showed high percent recovery with ±RSD. The recoveries of urea in the three urine samples by spectrophotometric standard addition were 99.2%±5.37, 96.3%±4.49, 104.88%±4.99 and that of spectrophotometric 2nd order derivative method were 115.3%±5.2, 103.4%±2.6, 105.93%±0.76. The results show that these methods can open doors for a potential role of AgNPs in the clinical determination of urea in urine, blood, biological, non-biological fluids. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Spectrophotometric methods for the determination of urea in real samples using silver nanoparticles by standard addition and 2nd order derivative methods

    Science.gov (United States)

    Ali, Nauman; Ismail, Muhammad; Khan, Adnan; Khan, Hamayun; Haider, Sajjad; Kamal, Tahseen

    2018-01-01

    In this work, we have developed simple, sensitive and inexpensive methods for the spectrophotometric determination of urea in urine samples using silver nanoparticles (AgNPs). The standard addition and 2nd order derivative methods were adopted for this purpose. AgNPs were prepared by chemical reduction of AgNO3 with hydrazine using 1,3-di-(1H-imidazol-1-yl)-2-propanol (DIPO) as a stabilizing agent in aqueous medium. The proposed methods were based on the complexation of AgNPs with urea. Using this concept, urea in the urine samples was successfully determined spectrophotometric methods. The results showed high percent recovery with ± RSD. The recoveries of urea in the three urine samples by spectrophotometric standard addition were 99.2% ± 5.37, 96.3% ± 4.49, 104.88% ± 4.99 and that of spectrophotometric 2nd order derivative method were 115.3% ± 5.2, 103.4% ± 2.6, 105.93% ± 0.76. The results show that these methods can open doors for a potential role of AgNPs in the clinical determination of urea in urine, blood, biological, non-biological fluids.

  19. Controlled Vestibular Stimulation, Standardization Of A Physiological Method To Release Stress In College Students.

    Science.gov (United States)

    Sailesh, Kumar Sai; Mukkadan, J K

    2015-01-01

    The present study was designed to standardize optimal vestibular stimulation and to investigate its impact on anxiety levels in college students. Vestibular stimulation was achieved by swinging on a swing (Back to front direction) and the participants were advised to adjust frequency, duration and intensity, according to comfort. Frequency, intensity and duration were recorded manually. The anxiety status was assessed by using Spielberger state-trait anxiety inventory (STAI) before and after vestibular stimulation. It has been observed that the anxiety status was significantly decreased after vestibular stimulation. There is a need for future study with larger sample size to substantiate the therapeutic validity of vestibular stimulation as a physiological treatment for stress relief and stress related disorders among college students.

  20. Standard test method for translaminar fracture toughness of laminated and pultruded polymer matrix composite materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers the determination of translaminar fracture toughness, KTL, for laminated and pultruded polymer matrix composite materials of various ply orientations using test results from monotonically loaded notched specimens. 1.2 This test method is applicable to room temperature laboratory air environments. 1.3 Composite materials that can be tested by this test method are not limited by thickness or by type of polymer matrix or fiber, provided that the specimen sizes and the test results meet the requirements of this test method. This test method was developed primarily from test results of various carbon fiber – epoxy matrix laminates and from additional results of glass fiber – epoxy matrix, glass fiber-polyester matrix pultrusions and carbon fiber – bismaleimide matrix laminates (1-4, 6, 7). 1.4 A range of eccentrically loaded, single-edge-notch tension, ESE(T), specimen sizes with proportional planar dimensions is provided, but planar size may be variable and adjusted, with asso...

  1. Standard test method for determining the superplastic properties of metallic sheet materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the procedure for determining the superplastic forming properties (SPF) of a metallic sheet material. It includes tests both for the basic SPF properties and also for derived SPF properties. The test for basic properties encompasses effects due to strain hardening or softening. 1.2 This test method covers sheet materials with thicknesses of at least 0.5 mm but not greater than 6 mm. It characterizes the material under a uni-axial tensile stress condition. Note 1—Most industrial applications of superplastic forming involve a multi-axial stress condition in a sheet; however it is more convenient to characterize a material under a uni-axial tensile stress condition. Tests should be performed in different orientations to the rolling direction of the sheet to ascertain initial anisotropy. 1.3 This method has been used successfully between strain rates of 10-5 to 10-1 per second. 1.4 This method has been used successfully on Aluminum and Titanium alloys. The use of the method wi...

  2. Assessment of bone age in prepubertal healthy Korean children: Comparison among the Korean standard bone age chart, Greulich-Pyle method, and Tanner-Whitehouse method

    International Nuclear Information System (INIS)

    Kim Jeong Rye; Lee, Young Seok; Yu, Jee Suk

    2015-01-01

    To compare the reliability of the Greulich-Pyle (GP) method, Tanner-Whitehouse 3 (TW3) method and Korean standard bone age chart (KS) in the evaluation of bone age of prepubertal healthy Korean children. Left hand-wrist radiographs of 212 prepubertal healthy Korean children aged 7 to 12 years, obtained for the evaluation of the traumatic injury in emergency department, were analyzed by two observers. Bone age was estimated using the GP method, TW3 method and KS, and was calculated in months. The correlation between bone age measured by each method and chronological age of each child was analyzed using Pearson correlation coefficient, scatterplot. The three methods were compared using one-way analysis of variance. Significant correlations were found between chronological age and bone age estimated by all three methods in whole group and in each gender (R2 ranged from 0.87 to 0.9, p < 0.01). Although bone age estimated by KS was slightly closer to chronological age than those estimated by the GP and TW3 methods, the difference between three methods was not statistically significant (p > 0.01). The KS, GP, and TW3 methods show good reliability in the evaluation of bone age of prepubertal healthy Korean children without significant difference between them. Any are useful for evaluation of bone age in prepubertal healthy Korean children.

  3. Standard method for detecting Bombyx mori nucleopolyhedrovirus disease-resistant silkworm varieties

    Directory of Open Access Journals (Sweden)

    Yang Qiong

    Full Text Available ABSTRACT Bombyx mori nucleopolyhedrovirus (BmNPV disease is one of the most serious silkworm diseases, and it has caused great economic losses to the sericulture industry. So far, the disease has not been controlled effectively by therapeutic agents. Breeding resistant silkworm varieties breeding may be an effective way to improve resistance to BmNPV and reduce economic losses. A precise resistance-detection method will help to accelerate the breeding process. For this purpose, here we described the individual inoculation method (IIM. Details of the IIM include pathogen BmNPV preparation, mulberry leaf size, pathogen volume, rearing conditions, course of infection, and breeding conditions. Finally, a resistance comparison experiment was performed using the IIM and the traditional group inoculation method (GIM. The incidence of BmNPV infection and the within-group variance results showed that the IIM was more precise and reliable than the GIM.

  4. Validation of five minimally obstructive methods to estimate physical activity energy expenditure in young adults in semi-standardized settings

    DEFF Research Database (Denmark)

    Schneller, Mikkel Bo; Pedersen, Mogens Theisen; Gupta, Nidhi

    2015-01-01

    ActivPAL3 software (ActivPAL), ActiGraph GT3X+ (ActiGraph) and Actiheart (Actiheart), and by a combination of activity type recognition via Acti4 software and activity counts per minute (CPM) of either a hip- or thigh-worn ActiGraph GT3X+ (AGhip + Acti4 and AGthigh + Acti4). At group level, estimated......-standardized settings compared to previously validated methods using CPM only....

  5. A Comparison of pical Root Resorption in Incisors after Fixed Orthodontic Treatment with Standard Edgewise and Straight Wire (MBT) Method

    OpenAIRE

    Zahed Zahedani, SM; Oshagh, M; Momeni Danaei, Sh; Roeinpeikar, SMM

    2013-01-01

    Statement of Problem: One of the major outcomes of orthodontic treatment is the apical root resorption of teeth moved during the treatment. Identifying the possible risk factors, are necessary for every orthodontist. Purpose: The aim of this study was to compare the rate of apical root resorption after fixed orthodontic treatment with standard edgewise and straight wire (MBT) method, and also to evaluate other factors effecting the rate of root resorption in orthodontic treatments. Materials ...

  6. A Comparison of Apical Root Resorption in Incisors after Fixed Orthodontic Treatment with Standard Edgewise and Straight Wire (MBT) Method

    OpenAIRE

    Zahed Zahedani SM.; Oshagh M.; Momeni Danaei Sh.; Roeinpeikar SMM.

    2013-01-01

    Statement of Problem: One of the major outcomes of orthodontic treatment is the apical root resorption of teeth moved during the treatment. Identifying the possible risk factors, are necessary for every orthodontist. Purpose: The aim of this study was to compare the rate of apical root resorption after fixed orthodontic treatment with standard edgewise and straight wire (MBT) method, and also to evaluate other factors effecting the rate of root resorption in orthodontic treatments.Materials a...

  7. Method for Estimating Evaporative Potential (IM/CLO) from ASTM Standard Single Wind Velocity Measures

    Science.gov (United States)

    2016-08-10

    Introduction .................................................................................................................. 2 Methods...testing. 2 INTRODUCTION Sweating thermal manikins have long been used to provide biophysical measures of clothing and equipment worn by the...AW, Gonzalez JA, and Xu X. Ebola response: Modeling the risk of heat stress from personal protective clothing. PLoS ONE 10(11), e0143461, 2015. 16

  8. Standard Test Method for Autogenous Strain of Cement Paste and Mortar

    DEFF Research Database (Denmark)

    Jensen, Ole Mejlhede; Lura, Pietro; Goodwin, Fred

    This test method measures the bulk strain of a sealed cement paste or mortar specimen, including those containing admixtures, various supplementary cementitious materials (SCM), and other fine materials, at constant temperature and not subjected to external forces, from the time of final setting ...

  9. Standard Test Method for Determining Thermal Performance of Tracking Concentrating Solar Collectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This test method covers the determination of thermal performance of tracking concentrating solar collectors that heat fluids for use in thermal systems. 1.2 This test method applies to one- or two-axis tracking reflecting concentrating collectors in which the fluid enters the collector through a single inlet and leaves the collector through a single outlet, and to those collectors where a single inlet and outlet can be effectively provided, such as into parallel inlets and outlets of multiple collector modules. 1.3 This test method is intended for those collectors whose design is such that the effects of diffuse irradiance on performance is negligible and whose performance can be characterized in terms of direct irradiance. Note 1—For purposes of clarification, this method shall apply to collectors with a geometric concentration ratio of seven or greater. 1.4 The collector may be tested either as a thermal collection subsystem where the effects of tracking errors have been essentially removed from t...

  10. A method to standardize gait and balance variables for gait velocity.

    NARCIS (Netherlands)

    Iersel, M.B. van; Olde Rikkert, M.G.M.; Borm, G.F.

    2007-01-01

    Many gait and balance variables depend on gait velocity, which seriously hinders the interpretation of gait and balance data derived from walks at different velocities. However, as far as we know there is no widely accepted method to correct for effects of gait velocity on other gait and balance

  11. Standardization of a broth microdilution susceptibility testing method to determine minimum inhibitory concentrations of aquatic bacteria

    DEFF Research Database (Denmark)

    Miller, R.A.; Walker, R.D.; Carson, J.

    2005-01-01

    antimicrobial susceptibility testing methods for bacterial isolates from aquatic animal species. QC ranges were established for Escherichia coli ATCC 25922 and Aeromonas salmonicida subsp. salmonicida ATCC 33658 when testing at 22, 28 and 35 degrees C (E. coli only) for 10 different antimicrobial agents...

  12. Virtual standardized patients: an interactive method to examine variation in depression care among primary care physicians

    Science.gov (United States)

    Hooper, Lisa M.; Weinfurt, Kevin P.; Cooper, Lisa A.; Mensh, Julie; Harless, William; Kuhajda, Melissa C.; Epstein, Steven A.

    2009-01-01

    Background Some primary care physicians provide less than optimal care for depression (Kessler et al., Journal of the American Medical Association 291, 2581–90, 2004). However, the literature is not unanimous on the best method to use in order to investigate this variation in care. To capture variations in physician behaviour and decision making in primary care settings, 32 interactive CD-ROM vignettes were constructed and tested. Aim and method The primary aim of this methods-focused paper was to review the extent to which our study method – an interactive CD-ROM patient vignette methodology – was effective in capturing variation in physician behaviour. Specifically, we examined the following questions: (a) Did the interactive CD-ROM technology work? (b) Did we create believable virtual patients? (c) Did the research protocol enable interviews (data collection) to be completed as planned? (d) To what extent was the targeted study sample size achieved? and (e) Did the study interview protocol generate valid and reliable quantitative data and rich, credible qualitative data? Findings Among a sample of 404 randomly selected primary care physicians, our voice-activated interactive methodology appeared to be effective. Specifically, our methodology – combining interactive virtual patient vignette technology, experimental design, and expansive open-ended interview protocol – generated valid explanations for variations in primary care physician practice patterns related to depression care. PMID:20463864

  13. Evaluation of a Standardized Method of Quality Assurance in Mental Health Records: A Pilot Study

    Science.gov (United States)

    Bradshaw, Kelsey M.; Donohue, Bradley; Fayeghi, Jasmine; Lee, Tiffany; Wilks, Chelsey R.; Ross, Brendon

    2016-01-01

    The widespread adoption of research-supported treatments by mental health providers has facilitated empirical development of quality assurance (QA) methods. Research in this area has focused on QA systems aimed at assuring the integrity of research-supported treatment implementation, while examination of QA systems to assure appropriate…

  14. Linear shrinkage test: justification for its reintroduction as a standard South African test method

    CSIR Research Space (South Africa)

    Sampson, LR

    2009-06-04

    Full Text Available Several problems with the linear shrinkage test specified in Method A4 of the THM 1 1979 were addressed as part of this investigation in an effort to improve the alleged poor reproducibility of the test and justify its reintroduction into THM 1. A...

  15. Investigating Arsenic Contents in Surface and Drinking Water by Voltammetry and the Method of Standard Additions

    Science.gov (United States)

    Cheng, Anran; Tyne, Rebecca; Kwok, Yu Ting; Rees, Louis; Craig, Lorraine; Lapinee, Chaipat; D'Arcy, Mitch; Weiss, Dominik J.; Salau¨n, Pascal

    2016-01-01

    Testing water samples for arsenic contamination has become an important water quality issue worldwide. Arsenic usually occurs in very small concentrations, and a sensitive analytical method is needed. We present here a 1-day laboratory module developed to introduce Earth Sciences and/or Chemistry student undergraduates to key aspects of this…

  16. Standard test method for determining the orientation of a metal crystal

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the back-reflection Laue procedure for determining the orientation of a metal crystal. The back-reflection Laue method for determining crystal orientation (1, 2) may be applied to macrograins (3) (0.5-mm diameter or larger) within polycrystalline aggregates, as well as to single crystals of any size. The method is described with reference to cubic crystals; it can be applied equally well to hexagonal, tetragonal, or orthorhombic crystals. 1.2 Most natural crystals have well developed external faces, and the orientation of such crystals can usually be determined from inspection. The orientation of a crystal having poorly developed faces, or no faces at all (for example, a metal crystal prepared in the laboratory) must be determined by more elaborate methods. The most convenient and accurate of these involves the use of X-ray diffraction. The “orientation of a metal crystal” is known when the positions in space of the crystallographic axes of the unit cell have been located with...

  17. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures of Nonconducting Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 This test method describes an accurate technique for measuring the normal spectral emittance of electrically nonconducting materials in the temperature range from 1000 to 1800 K, and at wavelengths from 1 to 35 μm. It is particularly suitable for measuring the normal spectral emittance of materials such as ceramic oxides, which have relatively low thermal conductivity and are translucent to appreciable depths (several millimetres) below the surface, but which become essentially opaque at thicknesses of 10 mm or less. 1.2 This test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is particularly suitable for research laboratories, where the highest precision and accuracy are desired, and is not recommended for routine production or acceptance testing. Because of its high accuracy, this test method may be used as a reference method to be applied to production and acceptance testing in case of dispute. 1.3 This test metho...

  18. Standard test method for splitting tensile strength for brittle nuclear waste forms

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This test method is used to measure the static splitting tensile strength of cylindrical specimens of brittle nuclear waste forms. It provides splitting tensile-strength data that can be used to compare the strength of waste forms when tests are done on one size of specimen. 1.2 The test method is applicable to glass, ceramic, and concrete waste forms that are sufficiently homogeneous (Note 1) but not to coated-particle, metal-matrix, bituminous, or plastic waste forms, or concretes with large-scale heterogeneities. Cementitious waste forms with heterogeneities >1 to 2 mm and 5 mm can be tested using this procedure provided the specimen size is increased from the reference size of 12.7 mm diameter by 6 mm length, to 51 mm diameter by 100 mm length, as recommended in Test Method C 496 and Practice C 192. Note 1—Generally, the specimen structural or microstructural heterogeneities must be less than about one-tenth the diameter of the specimen. 1.3 This test method can be used as a quality control chec...

  19. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or non-uniform) shadowing or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials. 1.2 There are two ways that cells can cause a hot spot problem; either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high-current flow in a localized region. This test method selects cells of both types to be stressed. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method....

  20. Standardization of methods for microbiological examination of sludges in the special outlook of disinfection by ionizing radiations

    International Nuclear Information System (INIS)

    Alexandre, D.; Charrel, J.; Blancard, A.

    1978-01-01

    Scattering and difficulties in the interpretation of data regarding the level of radiation doses required for inactivation of microorganisms encountered in waste water and sludge, is due, in great part, to the lack of precision in operational conditions and to the diversity in analytical methods. After reminding the importance of the main physical and chemical parameters characterizing the media and liable to change the radio sensitivity of present germs, authors review the different methods used in microbiology for isolation and counting of the most generally studied microorganisms in view of standardization. (Auth.)

  1. Classification of Magnetic Nanoparticle Systems—Synthesis, Standardization and Analysis Methods in the NanoMag Project

    Directory of Open Access Journals (Sweden)

    Sara Bogren

    2015-08-01

    Full Text Available This study presents classification of different magnetic single- and multi-core particle systems using their measured dynamic magnetic properties together with their nanocrystal and particle sizes. The dynamic magnetic properties are measured with AC (dynamical susceptometry and magnetorelaxometry and the size parameters are determined from electron microscopy and dynamic light scattering. Using these methods, we also show that the nanocrystal size and particle morphology determines the dynamic magnetic properties for both single- and multi-core particles. The presented results are obtained from the four year EU NMP FP7 project, NanoMag, which is focused on standardization of analysis methods for magnetic nanoparticles.

  2. The energy calibration and precision of a gamma spectrometry unit - Method using the electron annihilation energy as the only standard

    International Nuclear Information System (INIS)

    Hoclet, Michel

    1971-06-01

    Spectrometry using Ge(Li) detectors is discussed. The excellent resolution of this type of detector, the mathematical analysis of the spectral lines of the pulses, and the reproducibility of the spectrometer enable highly accurate measurements of the abscises (some 10 -5 ) corresponding to the peaks. A method using the annihilation energy of the electron as the only standard was developed. The method is applied to the measurement of the gamma ray energies of the radioelements: 22 Na, 24 Na, 56 Mn, 56 Co, 59 Fe, 72 Ga, 88 Y, 122 Sb, 124 Sb and 137 Cs. (author) [fr

  3. Development of test practice requirements for a standard method on fracture toughness testing in the transition range

    International Nuclear Information System (INIS)

    McCabe, D.E.; Zerbst, U.; Heerens, J.

    1993-01-01

    This report covers the resolution of several issues that are relevant to the ductile to brittle transition range of structural steels. One of this issues was to compare a statistical-based weakest-link method to constraint data adjustment methods for modeling the specimen size effects on fracture toughness. Another was to explore the concept of a universal transition temperature curve shape (Master Curve). Data from a Materials Properties Council round robin activity were used to test the proposals empirically. The findings of this study are inclosed in an activity for the development of a draft standard test procedure ''Test Practice for Fracture Toughness in the Transition Range''. (orig.) [de

  4. Development of an automated method to detect sitting pivot transfer phases using biomechanical variables: toward a standardized method

    Directory of Open Access Journals (Sweden)

    Desroches Guillaume

    2012-02-01

    Full Text Available Abstract Background Sitting pivot transfer (SPT is one of the most important, but at the same time strenuous at the upper extremity, functional task for spinal cord injured individuals. In order to better teach this task to those individuals and to improve performance, a better biomechanical understanding during the different SPT phases is a prerequisite. However, no consensus has yet been reached on how to depict the different phases of the SPT. The definition of the phases of the SPT, along with the events characterizing these phases, will facilitate the interpretation of biomechanical outcome measures related to the performance of SPTs as well as strengthen the evidence generated across studies. Methods Thirty-five individuals with a spinal cord injury performed two SPTs between seats of similar height using their usual SPT technique. Kinematics and kinetics were recorded using an instrumented transfer assessment system. Based on kinetic and kinematic measurements, a relative threshold-based algorithm was developed to identify four distinct phases: pre-lift, upper arm loading, lift-pivot and post-lift phases. To determine the stability of the algorithm between the two SPTs, Student t-tests for dependent samples were performed on the absolute duration of each phase. Results The mean total duration of the SPT was 2.00 ± 0.49 s. The mean duration of the pre-lift, upper arm loading, lift-pivot and post-lift phases were 0.74 ± 0.29 s, 0.28 ± 0.13 s, 0.72 ± 0.24 s, 0.27 ± 0.14 s whereas their relative contributions represented approximately 35%, 15%, 35% and 15% of the overall SPT cycle, respectively. No significant differences were found between the trials (p = 0.480-0.891. Conclusion The relative threshold-based algorithm used to automatically detect the four distinct phases of the SPT, is rapid, accurate and repeatable. A quantitative and thorough description of the precise phases of the SPT is prerequisite to better interpret biomechanical

  5. Expression of Root Genes in Arabidopsis Seedlings Grown by Standard and Improved Growing Methods

    Directory of Open Access Journals (Sweden)

    Yanli Qu

    2017-05-01

    Full Text Available Roots of Arabidopsis thaliana seedlings grown in the laboratory using the traditional plant-growing culture system (TPG were covered to maintain them in darkness. This new method is based on a dark chamber and is named the improved plant-growing method (IPG. We measured the light conditions in dark chambers, and found that the highest light intensity was dramatically reduced deeper in the dark chamber. In the bottom and side parts of dark chambers, roots were almost completely shaded. Using the high-throughput RNA sequencing method on the whole RNA extraction from roots, we compared the global gene expression levels in roots of seedlings from these two conditions and identified 141 differently expressed genes (DEGs between them. According to the KEGG (Kyoto Encyclopedia of Genes and Genomes enrichment, the flavone and flavonol biosynthesis and flavonoid biosynthesis pathways were most affected among all annotated pathways. Surprisingly, no genes of known plant photoreceptors were identified as DEGs by this method. Considering that the light intensity was decreased in the IPG system, we collected four sections (1.5 cm for each of Arabidopsis roots grown in TPG and IPG conditions, and the spatial-related differential gene expression levels of plant photoreceptors and polar auxin transporters, including CRY1, CRY2, PHYA, PHYB, PHOT1, PHOT2, and UVR8 were analyzed by qRT-PCR. Using these results, we generated a map of the spatial-related expression patterns of these genes under IPG and TPG conditions. The expression levels of light-related genes in roots is highly sensitive to illumination and it provides a background reference for selecting an improved culture method for laboratory-maintained Arabidopsis seedlings.

  6. Expression of Root Genes in Arabidopsis Seedlings Grown by Standard and Improved Growing Methods.

    Science.gov (United States)

    Qu, Yanli; Liu, Shuai; Bao, Wenlong; Xue, Xian; Ma, Zhengwen; Yokawa, Ken; Baluška, František; Wan, Yinglang

    2017-05-03

    Roots of Arabidopsis thaliana seedlings grown in the laboratory using the traditional plant-growing culture system (TPG) were covered to maintain them in darkness. This new method is based on a dark chamber and is named the improved plant-growing method (IPG). We measured the light conditions in dark chambers, and found that the highest light intensity was dramatically reduced deeper in the dark chamber. In the bottom and side parts of dark chambers, roots were almost completely shaded. Using the high-throughput RNA sequencing method on the whole RNA extraction from roots, we compared the global gene expression levels in roots of seedlings from these two conditions and identified 141 differently expressed genes (DEGs) between them. According to the KEGG (Kyoto Encyclopedia of Genes and Genomes) enrichment, the flavone and flavonol biosynthesis and flavonoid biosynthesis pathways were most affected among all annotated pathways. Surprisingly, no genes of known plant photoreceptors were identified as DEGs by this method. Considering that the light intensity was decreased in the IPG system, we collected four sections (1.5 cm for each) of Arabidopsis roots grown in TPG and IPG conditions, and the spatial-related differential gene expression levels of plant photoreceptors and polar auxin transporters, including CRY1 , CRY2 , PHYA , PHYB , PHOT1 , PHOT2 , and UVR8 were analyzed by qRT-PCR. Using these results, we generated a map of the spatial-related expression patterns of these genes under IPG and TPG conditions. The expression levels of light-related genes in roots is highly sensitive to illumination and it provides a background reference for selecting an improved culture method for laboratory-maintained Arabidopsis seedlings.

  7. The Standard Days Method(®): efficacy, satisfaction and demand at regular family planning service delivery settings in Turkey.

    Science.gov (United States)

    Kursun, Zerrin; Cali, Sanda; Sakarya, Sibel

    2014-06-01

    To evaluate the demand, efficacy, and satisfaction concerning the Standard Days Method(®) (SDM; a fertility awareness method) as an option presented among other contraceptive methods at regular service delivery settings. The survey group consisted of 993 women who presented at the primary care units in Umraniye District of Istanbul, Turkey, between 1 October 2006 and 31 March 2008, and started to use a new method. Women were enrolled until reaching a limit of 250 new users for each method, or expiration of the six-month registration period. Participants were followed for up to one year of method use. The characteristics of women who chose the SDM were similar to those of participants who opted for other methods. The most common reasons for selecting it were that it is natural and causes no side effects. Fifty-one percent used the SDM for the full year, compared to 71% who chose an intrauterine device (IUD). Continuation rates were significantly lower for all other methods. During the one-year follow-up period, 12% of SDM-, 7% of pill-, 7% of condom-, 3% of monthly injection-, 1% of quarterly injection-, and 0.5% of IUD users became pregnant. The SDM had relatively high continuation rates and relatively good levels of satisfaction among participants and their husbands. It should be mentioned among the routinely offered contraceptive methods.

  8. Calibration of atomic force microscope cantilevers using standard and inverted static methods assisted by FIB-milled spatial markers.

    Science.gov (United States)

    Slattery, Ashley D; Blanch, Adam J; Quinton, Jamie S; Gibson, Christopher T

    2013-01-11

    Static methods to determine the spring constant of AFM cantilevers have been widely used in the scientific community since the importance of such calibration techniques was established nearly 20 years ago. The most commonly used static techniques involve loading a trial cantilever with a known force by pressing it against a pre-calibrated standard or reference cantilever. These reference cantilever methods have a number of sources of uncertainty, which include the uncertainty in the measured spring constant of the standard cantilever, the exact position of the loading point on the reference cantilever and how closely the spring constant of the trial and reference cantilever match. We present a technique that enables users to minimize these uncertainties by creating spatial markers on reference cantilevers using a focused ion beam (FIB). We demonstrate that by combining FIB spatial markers with an inverted reference cantilever method, AFM cantilevers can be accurately calibrated without the tip of the test cantilever contacting a surface. This work also demonstrates that for V-shaped cantilevers it is possible to determine the precise loading position by AFM imaging the section of the cantilever where the two arms join. Removing tip-to-surface contact in both the reference cantilever method and sensitivity calibration is a significant improvement, since this is an important consideration for AFM users that require the imaging tip to remain in pristine condition before commencing measurements. Uncertainties of between 5 and 10% are routinely achievable with these methods.

  9. Assessing the stock market volatility for different sectors in Malaysia by using standard deviation and EWMA methods

    Science.gov (United States)

    Saad, Shakila; Ahmad, Noryati; Jaffar, Maheran Mohd

    2017-11-01

    Nowadays, the study on volatility concept especially in stock market has gained so much attention from a group of people engaged in financial and economic sectors. The applications of volatility concept in financial economics can be seen in valuation of option pricing, estimation of financial derivatives, hedging the investment risk and etc. There are various ways to measure the volatility value. However for this study, two methods are used; the simple standard deviation and Exponentially Weighted Moving Average (EWMA). The focus of this study is to measure the volatility on three different sectors of business in Malaysia, called primary, secondary and tertiary by using both methods. The daily and annual volatilities of different business sector based on stock prices for the period of 1 January 2014 to December 2014 have been calculated in this study. Result shows that different patterns of the closing stock prices and return give different volatility values when calculating using simple method and EWMA method.

  10. Human experimental pain models: A review of standardized methods in drug development

    Directory of Open Access Journals (Sweden)

    K. Sunil kumar Reddy

    2012-01-01

    Full Text Available Human experimental pain models are essential in understanding the pain mechanisms and appear to be ideally suited to test analgesic compounds. The challenge that confronts both the clinician and the scientist is to match specific treatments to different pain-generating mechanisms and hence reach a pain treatment tailored to each individual patient. Experimental pain models offer the possibility to explore the pain system under controlled settings. Standardized stimuli of different modalities (i.e., mechanical, thermal, electrical, or chemical can be applied to the skin, muscles, and viscera for a differentiated and comprehensive assessment of various pain pathways and mechanisms. Using a multimodel-multistructure testing, the nociception arising from different body structures can be explored and modulation of specific biomarkers by new and existing analgesic drugs can be profiled. The value of human experimental pain models is to link animal and clinical pain studies, providing new possibilities for designing successful clinical trials. Spontaneous pain, the main compliant of the neuropathic patients, but currently there is no human model available that would mimic chronic pain. Therefore, current human pain models cannot replace patient studies for studying efficacy of analgesic compounds, although being helpful for proof-of-concept studies and dose finding.

  11. Standardization of a molecular diagnostic method for Cucumber mosaic virus (cmv in Ecuadorian bananas

    Directory of Open Access Journals (Sweden)

    Johanna Liseth Buitrón-Bustamante

    2017-01-01

    Full Text Available Several pests and diseases affect banana crop in Ecuador and Cucumber mosaic virus (cmv is one of the most important pathogens. The aim of this research was to standardize a new molecular approach to achieve a sensitive and highly specific detection of cmv in Ecuadorian bananas. Specific primers were designed from the sequence encodingResumoA cultura da banana no Equador vê-se afetada por uma série de doenças, das quais o cucumber mosaic vírus(cmv é um dos fitopatógenos mais impor-tantes. Com este estudo procurou-se padronizar uma técnica molecular para a detecção sensível e altamente específica deste agente viral na banana equatoriana. Para este fim, realizou-se o desenho de primers específicos, a partir da sequência que se codifica para a proteína da cápside do vírus. for the virus capsid protein. PC-F1, PC-R D1 and K-F primers, obtained from cDNA replicated from R NA of infected banana, allowed accurate virus detection by Reverse transcription and Hemi-nested PCR. Virus detection was possible even in asymptomatic plants, providing a tech-nology with potential use for the Ecuadorian banana producers.

  12. Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives.

    Science.gov (United States)

    Verkouteren, Jennifer R; Lawrence, Jeffrey A; Staymates, Matthew E; Sisco, Edward

    2017-04-10

    One of the limiting steps to detecting traces of explosives at screening venues is effective collection of the sample. Wipe-sampling is the most common procedure for collecting traces of explosives, and standardized measurements of collection efficiency are needed to evaluate and optimize sampling protocols. The approach described here is designed to provide this measurement infrastructure, and controls most of the factors known to be relevant to wipe-sampling. Three critical factors (the applied force, travel distance, and travel speed) are controlled using an automated device. Test surfaces are chosen based on similarity to the screening environment, and the wipes can be made from any material considered for use in wipe-sampling. Particle samples of the explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) are applied in a fixed location on the surface using a dry-transfer technique. The particle samples, recently developed to simulate residues made after handling explosives, are produced by inkjet printing of RDX solutions onto polytetrafluoroethylene (PTFE) substrates. Collection efficiency is measured by extracting collected explosive from the wipe, and then related to critical sampling factors and the selection of wipe material and test surface. These measurements are meant to guide the development of sampling protocols at screening venues, where speed and throughput are primary considerations.

  13. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  14. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide powder and pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Total Carbon by Combustion and Gravimetry 7-17 Total Boron by Titrimetry 18-28 Isotopic Composition by Mass Spectrometry 29-38 Chloride and Fluoride Separation by Pyrohydrolysis 39-45 Chloride by Constant-Current Coulometry 46-54 Fluoride by Ion-Selective Electrode 55-63 Water by Constant-Voltage Coulometry 64-72 Impurities by Spectrochemical Analysis 73-81 Soluble Boron by Titrimetry 82-95 Soluble Carbon by a Manometric Measurement 96-105 Metallic Impurities by a Direct Reader Spectrometric Method 106-114

  15. A new method for processing INAA results without the necessity of standards

    International Nuclear Information System (INIS)

    Hemon, G.; Philippot, J.C.

    1986-01-01

    When neutron activation analysis is used for elemental determinations in samples taken from environment, and quite different in origin, certain questions arise: is the method absolute or relative, precise or accurate? How should objects be chosen to represent the subject studied? How should the conclusions of the measurement be used? How are the quality and intensity of the flux to be controlled? What corrections are needed for the effects of perturbing elements, uranium and boron? How sensitive is the method or - which amounts to the same thing - what is the best time to analyse an element in a given matrix? The authors attempt to answer these questions and illustrate the subject by way of a few specific examples: mineral and river water, sea and river sediments, aerosols, quartz tools, hair, nodules and Mn deposits, diamonds, wines, PWR effluents. (author)

  16. Liquid Scintillation Counting Standardization of 22NaCl by te CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-01-01

    We describe a procedure for preparing a stable solution of ''22NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4 % and an overall uncertainty of 0.35 %. (Author) 4 refs

  17. Liquid Scintillation counting Standardization of 22 NaCl by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-09-01

    We describe a procedure for preparing a stable solution of ''22 NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4/% and an overall uncertainty of 0.35%

  18. Accuracy of genomic selection methods in a standard data set of loblolly pine (Pinus taeda L.).

    Science.gov (United States)

    Resende, M F R; Muñoz, P; Resende, M D V; Garrick, D J; Fernando, R L; Davis, J M; Jokela, E J; Martin, T A; Peter, G F; Kirst, M

    2012-04-01

    Genomic selection can increase genetic gain per generation through early selection. Genomic selection is expected to be particularly valuable for traits that are costly to phenotype and expressed late in the life cycle of long-lived species. Alternative approaches to genomic selection prediction models may perform differently for traits with distinct genetic properties. Here the performance of four different original methods of genomic selection that differ with respect to assumptions regarding distribution of marker effects, including (i) ridge regression-best linear unbiased prediction (RR-BLUP), (ii) Bayes A, (iii) Bayes Cπ, and (iv) Bayesian LASSO are presented. In addition, a modified RR-BLUP (RR-BLUP B) that utilizes a selected subset of markers was evaluated. The accuracy of these methods was compared across 17 traits with distinct heritabilities and genetic architectures, including growth, development, and disease-resistance properties, measured in a Pinus taeda (loblolly pine) training population of 951 individuals genotyped with 4853 SNPs. The predictive ability of the methods was evaluated using a 10-fold, cross-validation approach, and differed only marginally for most method/trait combinations. Interestingly, for fusiform rust disease-resistance traits, Bayes Cπ, Bayes A, and RR-BLUB B had higher predictive ability than RR-BLUP and Bayesian LASSO. Fusiform rust is controlled by few genes of large effect. A limitation of RR-BLUP is the assumption of equal contribution of all markers to the observed variation. However, RR-BLUP B performed equally well as the Bayesian approaches.The genotypic and phenotypic data used in this study are publically available for comparative analysis of genomic selection prediction models.

  19. Standard test method for determining liquidus temperature of immobilized waste glasses and simulated waste glasses

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These practices cover procedures for determining the liquidus temperature (TL) of nuclear waste, mixed nuclear waste, simulated nuclear waste, or hazardous waste glass in the temperature range from 600°C to 1600°C. This method differs from Practice C829 in that it employs additional methods to determine TL. TL is useful in waste glass plant operation, glass formulation, and melter design to determine the minimum temperature that must be maintained in a waste glass melt to make sure that crystallization does not occur or is below a particular constraint, for example, 1 volume % crystallinity or T1%. As of now, many institutions studying waste and simulated waste vitrification are not in agreement regarding this constraint (1). 1.2 Three methods are included, differing in (1) the type of equipment available to the analyst (that is, type of furnace and characterization equipment), (2) the quantity of glass available to the analyst, (3) the precision and accuracy desired for the measurement, and (4) candi...

  20. DETECTION OF MICROVASCULAR COMPLICATIONS OF TYPE 2 DIABETES BY EZSCAN AND ITS COMPARISON WITH STANDARD SCREENING METHODS

    Directory of Open Access Journals (Sweden)

    Sarita Bajaj

    2016-08-01

    Full Text Available BACKGROUND EZSCAN is a new, noninvasive technique to detect sudomotor dysfunction and thus neuropathy in diabetes patients at an early stage. It further predicts chances of development of other microvascular complications. In this study, we evaluated EZSCAN for detection of microvascular complications in Type 2 diabetes patients and compared accuracy of EZSCAN with standard screening methods. MATERIALS AND METHODS 104 known diabetes patients, 56 males and 48 females, were studied. All cases underwent the EZSCAN test, Nerve Conduction Study (NCS test, Vibration perception threshold test (VPT, Monofilament test, Fundus examination and Urine micral test. The results of EZSCAN were compared with standard screening methods. The data has been analysed and assessed by applying appropriate statistical tests within different groups. RESULTS Mean age of the subjects was 53.5 ± 11.4 years. For detection of diabetic neuropathy, sensitivity and specificity of EZSCAN was found to be 77.0 % and 95.3%, respectively. Odd’s ratio (OR was 68.82 with p < 0.0001. AUC in ROC curve was 0.930. Sensitivity and specificity of EZSCAN for detection of nephropathy were 67.1% and 94.1%, respectively. OR = 32.69 with p < 0.0001. AUC was 0.926. Sensitivity of EZSCAN for detection of retinopathy was 90% while specificity is 70.3%. OR = 21.27; p< 0.0001. AUC came out to be 0.920. CONCLUSION Results of EZSCAN test compared significantly to the standard screening methods for the detection of microvascular complications of diabetes and can be used as a simple, noninvasive and quick method to detect microvascular complications of diabetes.

  1. Standardization of sample collection, isolation and analysis methods in extracellular vesicle research

    Directory of Open Access Journals (Sweden)

    Kenneth W. Witwer

    2013-05-01

    Full Text Available The emergence of publications on extracellular RNA (exRNA and extracellular vesicles (EV has highlighted the potential of these molecules and vehicles as biomarkers of disease and therapeutic targets. These findings have created a paradigm shift, most prominently in the field of oncology, prompting expanded interest in the field and dedication of funds for EV research. At the same time, understanding of EV subtypes, biogenesis, cargo and mechanisms of shuttling remains incomplete. The techniques that can be harnessed to address the many gaps in our current knowledge were the subject of a special workshop of the International Society for Extracellular Vesicles (ISEV in New York City in October 2012. As part of the “ISEV Research Seminar: Analysis and Function of RNA in Extracellular Vesicles (evRNA”, 6 round-table discussions were held to provide an evidence-based framework for isolation and analysis of EV, purification and analysis of associated RNA molecules, and molecular engineering of EV for therapeutic intervention. This article arises from the discussion of EV isolation and analysis at that meeting. The conclusions of the round table are supplemented with a review of published materials and our experience. Controversies and outstanding questions are identified that may inform future research and funding priorities. While we emphasize the need for standardization of specimen handling, appropriate normative controls, and isolation and analysis techniques to facilitate comparison of results, we also recognize that continual development and evaluation of techniques will be necessary as new knowledge is amassed. On many points, consensus has not yet been achieved and must be built through the reporting of well-controlled experiments.

  2. Variability of assay methods for total and free PSA after WHO standardization.

    Science.gov (United States)

    Foj, L; Filella, X; Alcover, J; Augé, J M; Escudero, J M; Molina, R

    2014-03-01

    The variability of total PSA (tPSA) and free PSA (fPSA) results among commercial assays has been suggested to be decreased by calibration to World Health Organization (WHO) reference materials. To characterize the current situation, it is necessary to know its impact in the critical cutoffs used in clinical practice. In the present study, we tested 167 samples with tPSA concentrations of 0 to 20 μg/L using seven PSA and six fPSA commercial assays, including Access, ARCHITECT i2000, ADVIA Centaur XP, IMMULITE 2000, Elecsys, and Lumipulse G1200, in which we only measured tPSA. tPSA and fPSA were measured in Access using the Hybritech and WHO calibrators. Passing-Bablok analysis was performed for PSA, and percentage of fPSA with the Hybritech-calibrated access comparison assay. For tPSA, relative differences were more than 10 % at 0.2 μg/L for ARCHITECT i2000, and at a critical concentration of 3, 4, and 10 μg/L, the relative difference was exceeded by ADVIA Centaur XP and WHO-calibrated Access. For percent fPSA, at a critical concentration of 10 %, the 10 % relative difference limit was exceeded by IMMULITE 2000 assay. At a critical concentration of 20 and 25 %, ADVIA Centaur XP, ARCHITECT i2000, and IMMULITE 2000 assays exceeded the 10 % relative difference limit. We have shown significant discordances between assays included in this study despite advances in standardization conducted in the last years. Further harmonization efforts are required in order to obtain a complete clinical concordance.

  3. Standardization of sample collection, isolation and analysis methods in extracellular vesicle research

    Science.gov (United States)

    Witwer, Kenneth W.; Buzás, Edit I.; Bemis, Lynne T.; Bora, Adriana; Lässer, Cecilia; Lötvall, Jan; Nolte-‘t Hoen, Esther N.; Piper, Melissa G.; Sivaraman, Sarada; Skog, Johan; Théry, Clotilde; Wauben, Marca H.; Hochberg, Fred

    2013-01-01

    The emergence of publications on extracellular RNA (exRNA) and extracellular vesicles (EV) has highlighted the potential of these molecules and vehicles as biomarkers of disease and therapeutic targets. These findings have created a paradigm shift, most prominently in the field of oncology, prompting expanded interest in the field and dedication of funds for EV research. At the same time, understanding of EV subtypes, biogenesis, cargo and mechanisms of shuttling remains incomplete. The techniques that can be harnessed to address the many gaps in our current knowledge were the subject of a special workshop of the International Society for Extracellular Vesicles (ISEV) in New York City in October 2012. As part of the “ISEV Research Seminar: Analysis and Function of RNA in Extracellular Vesicles (evRNA)”, 6 round-table discussions were held to provide an evidence-based framework for isolation and analysis of EV, purification and analysis of associated RNA molecules, and molecular engineering of EV for therapeutic intervention. This article arises from the discussion of EV isolation and analysis at that meeting. The conclusions of the round table are supplemented with a review of published materials and our experience. Controversies and outstanding questions are identified that may inform future research and funding priorities. While we emphasize the need for standardization of specimen handling, appropriate normative controls, and isolation and analysis techniques to facilitate comparison of results, we also recognize that continual development and evaluation of techniques will be necessary as new knowledge is amassed. On many points, consensus has not yet been achieved and must be built through the reporting of well-controlled experiments. PMID:24009894

  4. Standardization of 3H, 14C and 63Ni radiation sources by calorimetric method

    International Nuclear Information System (INIS)

    Khol'nova, E.A.; Kul'kova, L.P.

    1979-01-01

    The calorimetric method of determination of activity of radionuclides 3 H, 14 C and 63 Ni with low mean energies of β-particles has, as compare to other methods which had been used for determination of activity of these nuclides, a number of advantages, because a nuclide to be measured can be introduced into the calorimeter in any physical and chemical state. It is not necessary to distroy integrity ane leek-proofness of a source wnich can be of arbitrary type. There is no correction for absorption and self-absorption of β-particles and measuring instruments are relatively simple. As a limitation of this method is it's low sensitivity which can be owercomed by means of application of modern high sensitivity calorimeters. Such calorimeters have been developed in the Mendeleev All-Union research Institute. The calorimetric installation consists of 3 independent β-calorimeters of differential-double type, working in the regime of heat equilibrium and beeng intended for different by sise and shape sources. Then, there are thermostatting device of special desighn and electric measuring device. Number of thermocouples in each calorimeter is from 75 to 120 and sensitivity of calorimeters is from 2.45x10 -7 to 4.5x10 -7 Bt/mm depending on the type of calorimeter. Calorimeters are intended for measuring activities from 10 9 to 10 12 Bk. Error of measurement of activities equals 0.8-1.5% (with confidence level of 0.99%). The main portion of error consists of error in the medium energy β-spectra. The calorimeter error itself is much more lower. Soueces, which have been measured in the calorimeter than can be used for preparation of solutions and sources of lower activity [ru

  5. A comparison of reliability of soil Cd determination by standard spectrometric methods

    Science.gov (United States)

    McBride, M.B.

    2015-01-01

    Inductively coupled plasma emission spectrometry (ICP-OES) is the most common method for determination of soil Cd, yet spectral and matrix interferences affect measurements at the available analytical wavelengths for this metal. This study evaluated the severity of the interference over a range of total soil Cd by comparing ICP-OES and ICP-MS measurements of Cd in acid digests. ICP-OES using the emission at 226.5 nm generally unable to quantify soil Cd at low (near-background) levels, and gave unreliable values compared to ICP-MS. Using the line at 228.nm, a marked positive bias in Cd measurement (relative to the 226.5 nm measurement) was attributable to As interference even at soil As concentrations below 10 mg/kg. This spectral interference in ICP-OES was severe in As-contaminated orchard soils, giving a false value for soil total Cd near 2 mg kg−1 when soil As was 100–150 mg kg−1. In attempting to avoid these ICP emission-specific interferences, we evaluated a method to estimate total soil Cd using 1 M HNO3 extraction followed by determination of Cd by flame atomic absorption (FAA), either with or without pre-concentration of Cd using an Aliquat-heptanone extractant. The 1 M HNO3 extracted an average of 82% of total soil Cd. The FAA method had no significant interferences, and estimated the total Cd concentrations in all soils tested with acceptable accuracy. For Cd-contaminated soils, the Aliquat-heptanone pre-concentration step was not necessary, as FAA sensitivity was adequate for quantification of extractable soil Cd and reliable estimation of total soil Cd. PMID:22031569

  6. Preparation of standard mixtures of gas hydrocarbons in air by the diffusion dilution method

    International Nuclear Information System (INIS)

    Garcia, M. R.; Perez, M. M.

    1979-01-01

    An original diffusion system able to produce continuously gaseous samples is described. This system can generate samples with concentrations of benzene in air from 0.1 to 1 ppm a reproducible way. The diffusion dilution method used Is also studied. The use of this diffusion system has been extended to the preparation of binary mixtures (benzene-toluene). Whit a secondary dilution device is possible preparing these mixtures over a wide range of concentrations (0.11 to 0.04 ppm for benzene and 0.06 to 0.02 for toluene). (Author) 7 refs

  7. Orthogonal analytical methods for botanical standardization: determination of green tea catechins by qNMR and LC-MS/MS.

    Science.gov (United States)

    Napolitano, José G; Gödecke, Tanja; Lankin, David C; Jaki, Birgit U; McAlpine, James B; Chen, Shao-Nong; Pauli, Guido F

    2014-05-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative (1)H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted (1)H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Reliability of the k{sub 0}-standardization method using geological sample analysed in a proficiency test

    Energy Technology Data Exchange (ETDEWEB)

    Pelaes, Ana Clara O.; Menezes, Maria Ângela de B.C., E-mail: anacpelaes@gmail.com, E-mail: menezes@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    The Neutron Activation Analysis (NAA) is an analytical technique to determine the elemental chemical composition in samples of several matrices, that has been applied by the Laboratory for Neutron Activation Analysis, located at Centro de Desenvolvimento da Tecnologia Nuclear /Comissão Nacional de Energia Nuclear (Nuclear Technology Development Center/Brazilian Commission for Nuclear Energy), CDTN/CNEN, since the starting up of the TRIGA MARK I IPR-R1 reactor, in 1960. Among the methods of application of the technique, the k{sub 0}-standardization method, which was established at CDTN in 1995, is the most efficient and in 2003 it was reestablished and optimized. In order to verify the reproducibility of the results generated by the application of the k{sub 0}-standardization method at CDTN, aliquots of a geological sample sent by WEPAL (Wageningen Evaluating Programs for Analytical Laboratories) were analysed and its results were compared with the results obtained through the Intercomparison of Results organized by the International Atomic Energy Agency in 2015. WEPAL is an accredited institution for the organisation of interlaboratory studies, preparing and organizing proficiency testing schemes all over the world. Therefore, the comparison with the results provided aims to contribute to the continuous improvement of the quality of the results obtained by the CDTN. The objective of this study was to verify the reliability of the method applied two years after the intercomparison round. (author)

  9. Standard test method for electrochemical reactivation (EPR) for detecting sensitization of AISI type 304 and 304L stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers a laboratory procedure for conducting an electrochemical reactivation (EPR) test on AISI Type 304 and 304L (UNS No. S30400 and S30403, respectively) stainless steels. This test method can provide a nondestructive means of quantifying the degree of sensitization in these steels (1, 2, 3). This test method has found wide acceptance in studies of the effects of sensitization on intergranular corrosion and intergranular stress corrosion cracking behavior (see Terminology G15). The EPR technique has been successfully used to evaluate other stainless steels and nickel base alloys (4), but the test conditions and evaluation criteria used were modified in each case from those cited in this test method. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this...

  10. Application of Monte Carlo Method for Evaluation of Uncertainties of ITS-90 by Standard Platinum Resistance Thermometer

    Science.gov (United States)

    Palenčár, Rudolf; Sopkuliak, Peter; Palenčár, Jakub; Ďuriš, Stanislav; Suroviak, Emil; Halaj, Martin

    2017-06-01

    Evaluation of uncertainties of the temperature measurement by standard platinum resistance thermometer calibrated at the defining fixed points according to ITS-90 is a problem that can be solved in different ways. The paper presents a procedure based on the propagation of distributions using the Monte Carlo method. The procedure employs generation of pseudo-random numbers for the input variables of resistances at the defining fixed points, supposing the multivariate Gaussian distribution for input quantities. This allows taking into account the correlations among resistances at the defining fixed points. Assumption of Gaussian probability density function is acceptable, with respect to the several sources of uncertainties of resistances. In the case of uncorrelated resistances at the defining fixed points, the method is applicable to any probability density function. Validation of the law of propagation of uncertainty using the Monte Carlo method is presented on the example of specific data for 25 Ω standard platinum resistance thermometer in the temperature range from 0 to 660 °C. Using this example, we demonstrate suitability of the method by validation of its results.

  11. ExSTA: External Standard Addition Method for Accurate High-Throughput Quantitation in Targeted Proteomics Experiments.

    Science.gov (United States)

    Mohammed, Yassene; Pan, Jingxi; Zhang, Suping; Han, Jun; Borchers, Christoph H

    2018-03-01

    Targeted proteomics using MRM with stable-isotope-labeled internal-standard (SIS) peptides is the current method of choice for protein quantitation in complex biological matrices. Better quantitation can be achieved with the internal standard-addition method, where successive increments of synthesized natural form (NAT) of the endogenous analyte are added to each sample, a response curve is generated, and the endogenous concentration is determined at the x-intercept. Internal NAT-addition, however, requires multiple analyses of each sample, resulting in increased sample consumption and analysis time. To compare the following three methods, an MRM assay for 34 high-to-moderate abundance human plasma proteins is used: classical internal SIS-addition, internal NAT-addition, and external NAT-addition-generated in buffer using NAT and SIS peptides. Using endogenous-free chicken plasma, the accuracy is also evaluated. The internal NAT-addition outperforms the other two in precision and accuracy. However, the curves derived by internal vs. external NAT-addition differ by only ≈3.8% in slope, providing comparable accuracies and precision with good CV values. While the internal NAT-addition method may be "ideal", this new external NAT-addition can be used to determine the concentration of high-to-moderate abundance endogenous plasma proteins, providing a robust and cost-effective alternative for clinical analyses or other high-throughput applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Standard test method for static leaching of monolithic waste forms for disposal of radioactive waste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a measure of the chemical durability of a simulated or radioactive monolithic waste form, such as a glass, ceramic, cement (grout), or cermet, in a test solution at temperatures <100°C under low specimen surface- area-to-leachant volume (S/V) ratio conditions. 1.2 This test method can be used to characterize the dissolution or leaching behaviors of various simulated or radioactive waste forms in various leachants under the specific conditions of the test based on analysis of the test solution. Data from this test are used to calculate normalized elemental mass loss values from specimens exposed to aqueous solutions at temperatures <100°C. 1.3 The test is conducted under static conditions in a constant solution volume and at a constant temperature. The reactivity of the test specimen is determined from the amounts of components released and accumulated in the solution over the test duration. A wide range of test conditions can be used to study material behavior, includin...

  13. Standard Test Method for Measuring Reaction Rates by Analysis of Barium-140 From Fission Dosimeters

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes two procedures for the measurement of reaction rates by determining the amount of the fission product 140Ba produced by the non-threshold reactions 235U(n,f), 241Am(n,f), and 239Pu(n,f), and by the threshold reactions 238U(n,f), 237Np(n,f), and 232Th(n,f). 1.2 These reactions produce many fission products, among which is 140Ba, having a half-life of 12.752 days. 140Ba emits gamma rays of several energies; however, these are not easily detected in the presence of other fission products. Competing activity from other fission products requires that a chemical separation be employed or that the 140Ba activity be determined indirectly by counting its daughter product 140La. This test method describes both procedure (a), the nondestructive determination of 140Ba by the direct counting of 140La several days after irradiation, and procedure (b), the chemical separation of 140Ba and the subsequent counting of 140Ba or its daughter 140La. 1.3 With suitable techniques, fission neutron fl...

  14. Standard test method for measurement of creep crack growth times in metals

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers the determination of creep crack growth (CCG) in metals at elevated temperatures using pre-cracked specimens subjected to static or quasi-static loading conditions. The time (CCI), t0.2 to an initial crack extension δai = 0.2 mm from the onset of first applied force and creep crack growth rate, ˙a or da/dt is expressed in terms of the magnitude of creep crack growth relating parameters, C* or K. With C* defined as the steady state determination of the crack tip stresses derived in principal from C*(t) and Ct (1-14). The crack growth derived in this manner is identified as a material property which can be used in modeling and life assessment methods (15-25). 1.1.1 The choice of the crack growth correlating parameter C*, C*(t), Ct, or K depends on the material creep properties, geometry and size of the specimen. Two types of material behavior are generally observed during creep crack growth tests; creep-ductile (1-14) and creep-brittle (26-37). In creep ductile materials, where cr...

  15. Test and standardization of a radiometric method for free testosterone assay in biological materials

    International Nuclear Information System (INIS)

    Mathor, M.B.

    1983-01-01

    The principles of equilibrium dialysis technique using semi-permeable cellulose membranes were analysed and a modification was presented for the calculation of the unbound or free fraction of plasma steroids. The results were compared with those from the classical way of calculation used in the equilibrium dialysis technique in which it is necessary to include the change in weight of the dialysis bags. Technical aspects of the method were studied such as weight variation of the dialysis bags during dialysis, comparison of the results obtained using multiple plasma dilutions or one dilution only and comparing serum and plasma. The results obtained with the multiple dilutions technique were similar to those with non-diluted plasma while significantly different from those using one dilution only. The operational characteristics of the method were evaluated showing its specificity at least by the dilution test, besides being precise considering intra and interassay reproductibility. The mean + - s.d. of the percent free testosterone levels were 2.57 + - 0.45% and 1.67 + - 0.30% for males and females at the mid-follicular phase respectively. (Author) [pt

  16. Standard test method for determination of impurities in nuclear grade uranium compounds by inductively coupled plasma mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of 67 elements in uranium dioxide samples and nuclear grade uranium compounds and solutions without matrix separation by inductively coupled plasma mass spectrometry (ICP-MS). The elements are listed in Table 1. These elements can also be determined in uranyl nitrate hexahydrate (UNH), uranium hexafluoride (UF6), triuranium octoxide (U3O8) and uranium trioxide (UO3) if these compounds are treated and converted to the same uranium concentration solution. 1.2 The elements boron, sodium, silicon, phosphorus, potassium, calcium and iron can be determined using different techniques. The analyst's instrumentation will determine which procedure is chosen for the analysis. 1.3 The test method for technetium-99 is given in Annex A1. 1.4 The values stated in SI units are to be regarded as standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish ...

  17. Underestimation of Self-Reported Smoking Prevalence in Korean Adolescents: Evidence from Gold Standard by Combined Method.

    Science.gov (United States)

    Hwang, Jun Hyun; Kim, Jong Yeon; Lee, Do Hoon; Jung, Hye Gyoun; Park, Soon-Woo

    2018-04-05

    The objective of this study was to evaluate the validity of self-reported smoking prevalence in Korean adolescents by using an improved gold standard by a combined method. Using a stratified sampling method, we selected 13 schools from among 397 high schools that participated in the 2015 Korean Youth Health Risk Behavior Web-Based Survey (KYRBS). A second survey (repeated self-reporting questionnaire and urinary cotinine test) was conducted on 1058 students who completed the KYRBS. The gold standard of current smoker was defined as those either self-reporting as a smoker in the second survey or having a urinary cotinine concentration ≥50 ng/mL. The current smoking prevalence in the first survey (KYRBS) was 7.9% (boys 16.5% and girls 1.8%), which was lower than the results based on gold standard (11.3% total, boys 21.9% and girls 3.7%). The sensitivity and specificity of self-reported smoking status was 62.5% and 99.0%, respectively. In particular, the sensitivity of girls (43.5%) was lower than that of boys (67.0%). The self-reported smoking prevalence in Korean adolescents was underestimated, particularly among girls. Careful attention should be paid to interpreting adolescents' smoking prevalence, and supplementary surveys or periodic validity tests need to be considered in Asian countries.

  18. Comparison of Standard Culture-Based Method to Culture-Independent Method for Evaluation of Hygiene Effects on the Hand Microbiome.

    Science.gov (United States)

    Zapka, C; Leff, J; Henley, J; Tittl, J; De Nardo, E; Butler, M; Griggs, R; Fierer, N; Edmonds-Wilson, S

    2017-03-28

    Hands play a critical role in the transmission of microbiota on one's own body, between individuals, and on environmental surfaces. Effectively measuring the composition of the hand microbiome is important to hand hygiene science, which has implications for human health. Hand hygiene products are evaluated using standard culture-based methods, but standard test methods for culture-independent microbiome characterization are lacking. We sampled the hands of 50 participants using swab-based and glove-based methods prior to and following four hand hygiene treatments (using a nonantimicrobial hand wash, alcohol-based hand sanitizer [ABHS], a 70% ethanol solution, or tap water). We compared results among culture plate counts, 16S rRNA gene sequencing of DNA extracted directly from hands, and sequencing of DNA extracted from culture plates. Glove-based sampling yielded higher numbers of unique operational taxonomic units (OTUs) but had less diversity in bacterial community composition than swab-based sampling. We detected treatment-induced changes in diversity only by using swab-based samples ( P microbiome studies. On the basis of our results and previously published studies, we propose recommendations for best practices in hand microbiome research. IMPORTANCE The hand microbiome is a critical area of research for diverse fields, such as public health and forensics. The suitability of culture-independent methods for assessing effects of hygiene products on microbiota has not been demonstrated. This is the first controlled laboratory clinical hand study to have compared traditional hand hygiene test methods with newer culture-independent characterization methods typically used by skin microbiologists. This study resulted in recommendations for hand hygiene product testing, development of methods, and future hand skin microbiome research. It also demonstrated the importance of inclusion of skin physiological metadata in skin microbiome research, which is atypical for skin

  19. Determination of avermectins by the internal standard recovery correction - high performance liquid chromatography - quantitative Nuclear Magnetic Resonance method.

    Science.gov (United States)

    Zhang, Wei; Huang, Ting; Li, Hongmei; Dai, Xinhua; Quan, Can; He, Yajuan

    2017-09-01

    Quantitative Nuclear Magnetic Resonance (qNMR) is widely used to determine the purity of organic compounds. For the compounds with lower purity especially molecular weight more than 500, qNMR is at risk of error for the purity, because the impurity peaks are likely to be incompletely separated from the peak of major component. In this study, an offline ISRC-HPLC-qNMR (internal standard recovery correction - high performance liquid chromatography - qNMR) was developed to overcome this problem. It is accurate by excluding the influence of impurity; it is low-cost by using common mobile phase; and it extends the applicable scope of qNMR. In this method, a mix solution of the sample and an internal standard was separated by HPLC with common mobile phases, and only the eluents of the analyte and the internal standard were collected in the same tube. After evaporation and re-dissolution, it was determined by qNMR. A recovery correction factor was determined by comparison of the solutions before and after these procedures. After correction, the mass fraction of analyte was constant and it was accurate and precise, even though the sample loss varied during these procedures, or even in bad resolution of HPLC. Avermectin B 1 a with the purity of ~93% and the molecular weight of 873 was analyzed. Moreover, the homologues of avermectin B 1 a were determined based on the identification and quantitative analysis by tandem mass spectrometry and HPLC, and the results were consistent with the results of traditional mass balance method. The result showed that the method could be widely used for the organic compounds, and could further promote qNMR to become a primary method in the international metrological systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Molecular identification of mumps virus genotypes from clinical samples: standardized method of analysis.

    Science.gov (United States)

    Palacios, G; Jabado, O; Cisterna, D; de Ory, F; Renwick, N; Echevarria, J E; Castellanos, A; Mosquera, M; Freire, M C; Campos, R H; Lipkin, W I

    2005-04-01

    A sensitive nested reverse transcription-PCR assay, targeting a short fragment of the gene encoding the small hydrophobic protein (SH gene), was developed to allow rapid characterization of mumps virus in clinical samples. The sensitivity and specificity of the assay were established using representative genotypes A, B, C, D, E, and F. Mumps virus RNA was characterized directly from cerebrospinal fluid (CSF) samples and in extracts of mumps virus isolates from patients with various clinical syndromes. Direct sequencing of products and subsequent phylogenetic analysis enabled genetic classification. A simple web-based system of sequence analysis was established. The study also allowed characterization of mumps virus strains from Argentina as part of a new subgenotype. This PCR assay for characterization of mumps infections coupled to a web-based analytical program provides a rapid method for identification of known and novel strains.